Lenovo YUM Repository
Targeted Server Family (Machine Type): ThinkSystem SR530 (7X07,7X08) |
Targeted Operating System: SLES11SP4_Default |
YUM Repository Build Date: 2017_12_06 |
Jump to RPM listing |
Suggested usage directions: |
1) Create a SLES11SP4_Default YUM repository configuration file named:
/etc/zypp/repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
| |
3) Install/Update Commands: | Initial INSTALL of updated drivers for ALL supported devices:#zypper install --from lenovo '*'
Install specific rpm: #zypper install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #zypper update after configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
MotherBoard Video | Part Number: NA |
---|---|
deviceid: 19A20101 | |
Applicable RPM: xorg-x11-driver-video-default-7.4.0.1-0.99.1_1.x86_64.rpm | |
ThinkSystem 1Gb 2-port RJ45 LOM | Part Number: 7ZT7A00544 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port SFP+ LOM | Part Number: 7ZT7A00546 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port Base-T LOM | Part Number: 7ZT7A00548 |
deviceid: 17AA4020 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_5.05-3.52-1.1767.0-a_linux_x86-64 | |
Applicable RPM: intel-i40e-2.0.23-2.1.x86_64.rpm | |
Applicable RPM: intel-i40e-kmp-default-2.0.23_3.0.101_63-2.1.x86_64.rpm | |
Applicable RPM: intel-igb-5.3.5.7-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbe-kmp-default-5.0.7_3.0.101_63-14.1.x86_64.rpm | |
Applicable RPM: intel-ixgbe-5.0.7-14.1.x86_64.rpm | |
Applicable RPM: intel-igb-kmp-default-5.3.5.7_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-i40evf-kmp-default-2.0.22_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbevf-4.0.5-1.1.x86_64.rpm | |
Applicable RPM: intel-i40evf-2.0.22-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbevf-kmp-default-4.0.5_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-igbvf-2.3.9.6-1.1.x86_64.rpm | |
Applicable RPM: intel-igbvf-kmp-default-2.3.9.6_3.0.101_63-1.1.x86_64.rpm | |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Part Number: 7Y37A01082 |
deviceid: 1D490500 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_530-50.2.1-0601_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.702.06.00_sles11sp4-1.x86_64.rpm | |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Part Number: 7Y37A01082 |
deviceid: 1D490500 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_530-50.2.1-0925_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.702.06.00_sles11sp4-1.x86_64.rpm | |
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | Part Number: 7Y37A01083 |
deviceid: 1D490600 | |
Required Firmware Update Package: lnvgy_fw_sraidmr_730-24.21.0-0016_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.702.06.00_sles11sp4-1.x86_64.rpm | |
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01084 |
deviceid: 1D490601 | |
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01087 |
deviceid: 1D490604 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_930-50.2.1-0601_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.702.06.00_sles11sp4-1.x86_64.rpm | |
ThinkSystem 430-8i SAS/SATA 12Gb HBA | Part Number: 7Y37A01088 |
deviceid: 1D490200 | |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | Part Number: 7Y37A01090 |
deviceid: 1D490202 | |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | Part Number: 7Y37A01091 |
deviceid: 1D490203 | |
Required Firmware Update Package: lnvgy_fw_mpt35sas_430-3.03-06_linux_x86-64 | |
Applicable RPM: lsi-mpt3sas-kmp-default-22.00.01.00_sles11sp4-5.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex | Part Number: 7ZT7A00493 |
deviceid: 10DFE871 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_17b-oc14-11.4.1186.3-1_linux_x86-64 | |
Applicable RPM: brcm-be2net-kmp-default-11.4.1186.0_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | Part Number: 00AG560 |
deviceid: 10DFE81F | |
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Part Number: 00AG580 |
deviceid: 10DFE81E | |
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE | Part Number: 01CV770 |
deviceid: 10DFE874 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_17b-oc14-11.4.1186.3-1_linux_x86-64 | |
Applicable RPM: brcmfcoe-vector-map-xen-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: brcm-brcmfcoe-kmp-default-11.4.1186.5_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Applicable RPM: brcmfcoe-vector-map-default-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: brcm-be2iscsi-kmp-default-11.4.1182.0_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Applicable RPM: brcm-be2net-kmp-default-11.4.1186.0_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Intel X710-DA2 ML2 2x10GbE SFP+ adapter | Part Number: 00JY940 |
deviceid: 8086000D | |
Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
deviceid: 80860022 | |
ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | Part Number: 7ZT7A00533 |
deviceid: 80860005 | |
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00534 |
deviceid: 808600A2 | |
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 |
deviceid: 808600A1 | |
Intel X710-DA2 2x10GbE SFP+ adapter | Part Number: 7ZT7A00537 |
deviceid: 8086000A | |
Required Firmware Update Package: intc-lnvgy_fw_nic_5.05-3.52-1.1767.0-a_linux_x86-64 | |
Applicable RPM: intel-i40e-2.0.23-2.1.x86_64.rpm | |
Applicable RPM: intel-i40e-kmp-default-2.0.23_3.0.101_63-2.1.x86_64.rpm | |
Applicable RPM: intel-igb-5.3.5.7-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbe-kmp-default-5.0.7_3.0.101_63-14.1.x86_64.rpm | |
Applicable RPM: intel-ixgbe-5.0.7-14.1.x86_64.rpm | |
Applicable RPM: intel-igb-kmp-default-5.3.5.7_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-i40evf-kmp-default-2.0.22_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbevf-4.0.5-1.1.x86_64.rpm | |
Applicable RPM: intel-i40evf-2.0.22-1.1.x86_64.rpm | |
Applicable RPM: intel-ixgbevf-kmp-default-4.0.5_3.0.101_63-1.1.x86_64.rpm | |
Applicable RPM: intel-igbvf-2.3.9.6-1.1.x86_64.rpm | |
Applicable RPM: intel-igbvf-kmp-default-2.3.9.6_3.0.101_63-1.1.x86_64.rpm | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00482 |
deviceid: 17AA402c | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00484 |
deviceid: 17AA402d | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_20.6.4.3a_linux_x86-64 | |
Applicable RPM: broadcom-tg3-kmp-default-3.137q_3.0.101_63-1.sles11sp4.x86_64.rpm | |
ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00496 |
deviceid: 17AA0460 | |
ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00497 |
deviceid: 17AA4161 | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nxe-20.06.04.07_linux_x86-64 | |
Applicable RPM: bnxt_en-kmp-default-1.8.1_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
deviceid: 10DFE333 | |
Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
deviceid: 10DFE332 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-lp3x-11.4.168.8-1_linux_x86-64 | |
Applicable RPM: elx-vector-map-xen-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: elx-vector-map-default-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: elx-lpfc-kmp-default-11.4.168.0_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Emulex 8Gb FC Single-port HBA | Part Number: 4XC7A08220 |
deviceid: 10DFF140 | |
Emulex 8Gb FC Dual-port HBA | Part Number: 4XC7A08221 |
deviceid: 10DFF141 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-2.03x14-16_linux_x86-64 | |
Applicable RPM: elx-vector-map-xen-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: elx-vector-map-default-1-1.sles11sp4.x86_64.rpm | |
Applicable RPM: elx-lpfc-kmp-default-11.4.168.0_3.0.101_63-1.sles11sp4.x86_64.rpm | |
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Part Number: 01CV750 |
deviceid: 107702AE | |
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Part Number: 01CV760 |
deviceid: 107702AF | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_1.90.43-2690-2742.p_linux_x86-64 | |
Applicable RPM: qlgc-qla2xxx-kmp-default-8.07.00.51.11.3_k_3.0.101_63-1.sles11sp4.x86_64.rpm | |
Repository RPM Listing | ||||
---|---|---|---|---|
RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
bnxt_en-kmp-default-1.8.1_3.0.101_63-1.sles11sp4.x86_64.rpm | bnxt_en-kmp-default | 1.8.1_3.0.101_63 | 1.sles11sp4 | Broadcom NetXtreme Gigabit Ethernet and RoCE Driver |
brcm-be2iscsi-kmp-default-11.4.1182.0_3.0.101_63-1.sles11sp4.x86_64.rpm | brcm-be2iscsi-kmp-default | 11.4.1182.0_3.0.101_63 | 1.sles11sp4 | Emulex OneConnect Open-iSCSI Driver |
brcm-be2net-kmp-default-11.4.1186.0_3.0.101_63-1.sles11sp4.x86_64.rpm | brcm-be2net-kmp-default | 11.4.1186.0_3.0.101_63 | 1.sles11sp4 | Emulex NIC Driver |
brcm-brcmfcoe-kmp-default-11.4.1186.5_3.0.101_63-1.sles11sp4.x86_64.rpm | brcm-brcmfcoe-kmp-default | 11.4.1186.5_3.0.101_63 | 1.sles11sp4 | Broadcom - Emulex FCoE driver for Universal CNAs |
brcmfcoe-vector-map-default-1-1.sles11sp4.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
brcmfcoe-vector-map-xen-1-1.sles11sp4.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
broadcom-tg3-kmp-default-3.137q_3.0.101_63-1.sles11sp4.x86_64.rpm | broadcom-tg3-kmp-default | 3.137q_3.0.101_63 | 1.sles11sp4 | Broadcom NetXtreme driver for Linux |
elx-lpfc-kmp-default-11.4.168.0_3.0.101_63-1.sles11sp4.x86_64.rpm | elx-lpfc-kmp-default | 11.4.168.0_3.0.101_63 | 1.sles11sp4 | Emulex lpfc driver for Fibre Channel HBAs and Universal CNAs |
elx-vector-map-default-1-1.sles11sp4.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
elx-vector-map-xen-1-1.sles11sp4.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
intel-i40e-2.0.23-2.1.x86_64.rpm | intel-i40e | 2.0.23 | 2.1 | Intel(R) 40-10 Gigabit Ethernet Connection Network Driver |
intel-i40e-kmp-default-2.0.23_3.0.101_63-2.1.x86_64.rpm | intel-i40e-kmp-default | 2.0.23_3.0.101_63 | 2.1 | I40e Kernel Module |
intel-i40evf-2.0.22-1.1.x86_64.rpm | intel-i40evf | 2.0.22 | 1.1 | Intel(R) 40-10 Gigabit Ethernet Virtual Function Driver |
intel-i40evf-kmp-default-2.0.22_3.0.101_63-1.1.x86_64.rpm | intel-i40evf-kmp-default | 2.0.22_3.0.101_63 | 1.1 | I40evf Kernel Module |
intel-igb-5.3.5.7-1.1.x86_64.rpm | intel-igb | 5.3.5.7 | 1.1 | Intel(R) 82575/82576 PCI-Express Gigabit Ethernet support |
intel-igb-kmp-default-5.3.5.7_3.0.101_63-1.1.x86_64.rpm | intel-igb-kmp-default | 5.3.5.7_3.0.101_63 | 1.1 | Intel(R) 82575/82576 PCI-Express Gigabit Ethernet support |
intel-igbvf-2.3.9.6-1.1.x86_64.rpm | intel-igbvf | 2.3.9.6 | 1.1 | Intel(R) Gigabit Ethernet Connection |
intel-igbvf-kmp-default-2.3.9.6_3.0.101_63-1.1.x86_64.rpm | intel-igbvf-kmp-default | 2.3.9.6_3.0.101_63 | 1.1 | Intel(R) Gigabit Ethernet Connection |
intel-ixgbe-5.0.7-14.1.x86_64.rpm | intel-ixgbe | 5.0.7 | 14.1 | Intel(R) 10GbE PCI Express Linux Network Driver |
intel-ixgbe-kmp-default-5.0.7_3.0.101_63-14.1.x86_64.rpm | intel-ixgbe-kmp-default | 5.0.7_3.0.101_63 | 14.1 | Intel(R) 10GbE PCI Express Linux Network Driver |
intel-ixgbevf-4.0.5-1.1.x86_64.rpm | intel-ixgbevf | 4.0.5 | 1.1 | Intel(R) 10GbE PCI Express Virtual Function Driver |
intel-ixgbevf-kmp-default-4.0.5_3.0.101_63-1.1.x86_64.rpm | intel-ixgbevf-kmp-default | 4.0.5_3.0.101_63 | 1.1 | Intel(R) 10GbE PCI Express Virtual Function Driver |
lsi-megaraid_sas-kmp-default-07.702.06.00_sles11sp4-1.x86_64.rpm | lsi-megaraid_sas-kmp-default | 07.702.06.00_3.0.101_63 | 1 | LSI Megaraid_sas Driver Package |
lsi-mpt3sas-kmp-default-22.00.01.00_sles11sp4-5.x86_64.rpm | lsi-mpt3sas-kmp-default | 22.00.01.00_3.0.101_63 | 5 | LSI Fusion Kernel Module |
qlgc-qla2xxx-kmp-default-8.07.00.51.11.3_k_3.0.101_63-1.sles11sp4.x86_64.rpm | qlgc-qla2xxx-kmp-default | 8.07.00.51.11.3_k_3.0.101_63 | 1.sles11sp4 | Linux driver for the QLogic FC adapter |
xorg-x11-driver-video-default-7.4.0.1-0.99.1_1.x86_64.rpm | xorg-x11-driver-video | 7.4.0.1 | 0.99.1_1 | X.Org video drivers |
Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |