Lenovo YUM Repository
Targeted Server Family (Machine Type): ThinkSystem SR590 (7X98,7X99) |
Targeted Operating System: RHEL6.9 |
YUM Repository Build Date: 2018_05_31 |
Jump to RPM listing |
Suggested usage directions: |
1) Create a RHEL6.9 YUM repository configuration file named:
/etc/yum.repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
store: #cp RPM-GPG-KEY-LenovoYUM2018 /etc/pki/rpm-gpg/
| |
3) Install/Update Commands: | Initial INSTALL of updated drivers for specific device:#yum groupinstall deviceid
Find the deviceid for supported device below, muliple deviceid can be specified Initial INSTALL of updated drivers for ALL supported devices: #yum groupinstall LenovoUpdates
Install specific rpm: #yum install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #yum update after configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
MotherBoard Video | Part Number: NA |
---|---|
Applicable RPM: xorg-x11-drv-mga-default-1.6.3-11.el6_1.x86_64.rpm | |
ThinkSystem 1Gb 2-port RJ45 LOM | Part Number: 7ZT7A00544 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port SFP+ LOM | Part Number: 7ZT7A00546 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port Base-T LOM | Part Number: 7ZT7A00548 |
deviceid: 17AA4020 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.36-3.5x-1.1824.0-f_linux_x86-64 | |
Applicable RPM: kmod-ixgbe-5.3.3-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40e-2.3.6-1.el6.x86_64.rpm | |
Applicable RPM: kmod-igb-5.3.5.12-1.x86_64.rpm | |
Applicable RPM: kmod-ixgbevf-4.3.2-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40evf-3.2.5-1.el6.x86_64.rpm | |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Part Number: 7Y37A01082 |
deviceid: 1D490500 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_530-50.3.0-1032_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | |
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | Part Number: 7Y37A01083 |
deviceid: 1D490600 | |
Required Firmware Update Package: lnvgy_fw_sraidmr_730-24.21.0-0016_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | |
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01084 |
deviceid: 1D490601 | |
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01085 |
deviceid: 1D490602 | |
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01087 |
deviceid: 1D490604 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_930-50.3.0-1075_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | |
ThinkSystem 430-8i SAS/SATA 12Gb HBA | Part Number: 7Y37A01088 |
deviceid: 1D490200 | |
ThinkSystem 430-16i SAS/SATA 12Gb HBA | Part Number: 7Y37A01089 |
deviceid: 1D490201 | |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | Part Number: 7Y37A01090 |
deviceid: 1D490202 | |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | Part Number: 7Y37A01091 |
deviceid: 1D490203 | |
Required Firmware Update Package: lnvgy_fw_mpt35sas_430-5.01-06_linux_x86-64 | |
Applicable RPM: kmod-mpt3sas-24.125.01.00_el6.9-1.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex | Part Number: 7ZT7A00493 |
deviceid: 10DFE871 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
Applicable RPM: kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | Part Number: 00AG560 |
deviceid: 10DFE81F | |
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Part Number: 00AG580 |
deviceid: 10DFE81E | |
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE | Part Number: 01CV770 |
deviceid: 10DFE874 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
Applicable RPM: brcmfcoe-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-brcmfcoe-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2iscsi-11.4.1223.0-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter | Part Number: 4XC7A08228 |
Required Firmware Update Package: qlgc-lnvgy_fw_nic_ah-8.30.21-1_linux_x86-64 | |
Applicable RPM: kmod-qlgc-fastlinq-8.30.12.0-1.rhel6u9.x86_64.rpm | |
Applicable RPM: qlgc-libqedr-8.30.4.0-1.rhel6u9.x86_64.rpm | |
Intel X710-DA2 ML2 2x10GbE SFP+ adapter | Part Number: 00JY940 |
deviceid: 8086000D | |
Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
deviceid: 80860022 | |
ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | Part Number: 7ZT7A00533 |
deviceid: 80860005 | |
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00534 |
deviceid: 808600A2 | |
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 |
deviceid: 808600A1 | |
Intel X710-DA2 2x10GbE SFP+ adapter | Part Number: 7ZT7A00537 |
deviceid: 8086000A | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.36-3.5x-1.1824.0-f_linux_x86-64 | |
Applicable RPM: kmod-ixgbe-5.3.3-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40e-2.3.6-1.el6.x86_64.rpm | |
Applicable RPM: kmod-igb-5.3.5.12-1.x86_64.rpm | |
Applicable RPM: kmod-ixgbevf-4.3.2-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40evf-3.2.5-1.el6.x86_64.rpm | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00482 |
deviceid: 17AA402c | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00484 |
deviceid: 17AA402d | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_20.6.4.3a_linux_x86-64 | |
Applicable RPM: kmod-tg3-3.137q-1.rhel6u9.x86_64.rpm | |
ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00496 |
deviceid: 17AA0460 | |
ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00497 |
deviceid: 17AA4161 | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nxe-20.06.04.07_linux_x86-64 | |
Applicable RPM: kmod-bnxt_en-1.8.1-1.rhel6u9.x86_64.rpm | |
Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
deviceid: 10DFE333 | |
Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
deviceid: 10DFE332 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-lp3x-11.4.168.16-3_linux_x86-64 | |
Applicable RPM: elx-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | |
Emulex 8Gb FC Single-port HBA | Part Number: 4XC7A08220 |
deviceid: 10DFF140 | |
Emulex 8Gb FC Dual-port HBA | Part Number: 4XC7A08221 |
deviceid: 10DFF141 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-2.03x14-21_linux_x86-64 | |
Applicable RPM: elx-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | |
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Part Number: 01CV750 |
deviceid: 107702AE | |
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Part Number: 01CV760 |
deviceid: 107702AF | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_1.90.43-2690-2742.p_linux_x86-64 | |
Applicable RPM: kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | |
Repository RPM Listing | ||||
---|---|---|---|---|
RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
brcmfcoe-vector-map-1-1.rhel6u9.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
elx-vector-map-1-1.rhel6u9.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
kmod-bnxt_en-1.8.1-1.rhel6u9.x86_64.rpm | kmod-bnxt_en | 1.8.1 | 1.rhel6u9 | bnxt_en kernel module(s) |
kmod-brcm-be2iscsi-11.4.1223.0-1.rhel6u9.x86_64.rpm | kmod-brcm-be2iscsi | 11.4.1223.0 | 1.rhel6u9 | brcm-be2iscsi kernel module(s) |
kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | kmod-brcm-be2net | 11.4.1241.0 | 1.rhel6u9 | brcm-be2net kernel module(s) |
kmod-brcm-brcmfcoe-11.4.1241.0-1.rhel6u9.x86_64.rpm | kmod-brcm-brcmfcoe | 11.4.1241.0 | 1.rhel6u9 | brcm-brcmfcoe kernel module(s) |
kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | kmod-elx-lpfc | 11.4.168.11 | 1.rhel6u9 | elx-lpfc kernel module(s) |
kmod-i40e-2.3.6-1.el6.x86_64.rpm | kmod-i40e | 2.3.6 | 1.el6 | i40e kernel module(s) |
kmod-i40evf-3.2.5-1.el6.x86_64.rpm | kmod-i40evf | 3.2.5 | 1.el6 | i40evf kernel module(s) |
kmod-igb-5.3.5.12-1.x86_64.rpm | kmod-igb | 5.3.5.12 | 1 | igb kernel module(s) |
kmod-ixgbe-5.3.3-1.el6.x86_64.rpm | kmod-ixgbe | 5.3.3 | 1.el6 | ixgbe kernel module(s) |
kmod-ixgbevf-4.3.2-1.el6.x86_64.rpm | kmod-ixgbevf | 4.3.2 | 1.el6 | ixgbevf kernel module(s) |
kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | kmod-megaraid_sas | 07.703.07.00_el6.9 | 1 | megaraid_sas kernel module(s) |
kmod-mpt3sas-24.125.01.00_el6.9-1.x86_64.rpm | kmod-mpt3sas | 24.125.01.00_el6.9 | 1 | mpt3sas kernel module(s) |
kmod-qlgc-fastlinq-8.30.12.0-1.rhel6u9.x86_64.rpm | kmod-qlgc-fastlinq | 8.30.12.0 | 1.rhel6u9 | qlgc-fastlinq kernel module(s) |
kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | kmod-qlgc-qla2xxx | 8.07.00.51.06.0_k | 1.rhel6u9 | qlgc-qla2xxx kernel module(s) |
kmod-tg3-3.137q-1.rhel6u9.x86_64.rpm | kmod-tg3 | 3.137q | 1.rhel6u9 | tg3 kernel module(s) |
qlgc-libqedr-8.30.4.0-1.rhel6u9.x86_64.rpm | qlgc-libqedr | 8.30.4.0 | 1.rhel6u9 | QLogic libqedr libraries |
xorg-x11-drv-mga-default-1.6.3-11.el6_1.x86_64.rpm | xorg-x11-drv-mga | 1.6.3 | 11.el6_1 | Xorg X11 mga video driver |
Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |