Lenovo YUM Repository
| Targeted Server Family (Machine Type): ThinkSystem ST550 (7X09,7X10) |
| Targeted Operating System: SLES12SP2 |
| YUM Repository Build Date: 2018_05_31 |
| Jump to RPM listing |
Suggested usage directions: |
| 1) Create a SLES12SP2 YUM repository configuration file named:
/etc/zypp/repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
| 2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
| |
| 3) Install/Update Commands: | Initial INSTALL of updated drivers for ALL supported devices:#zypper install --from lenovo '*'
Install specific rpm: #zypper install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #zypper updateafter configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
| MotherBoard Video | Part Number: NA |
|---|---|
| Applicable RPM: lenovo-mgag200-kmp-default-sle12sp2_k4.4.21_69-1.2.x86_64.rpm | |
| ThinkSystem ST550/558 LOM | Part Number: NA |
| deviceid: 17AA4022 | |
| Required Firmware Update Package: intc-lnvgy_fw_nic_6.36-3.5x-1.1824.0-f_linux_x86-64 | |
| Inbox Driver Supported | |
| ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Part Number: 7Y37A01082 |
| deviceid: 1D490500 | |
| Required Firmware Update Package: lnvgy_fw_sraidmr35_530-50.3.0-1032_linux_x86-64 | |
| Applicable RPM: lsi-megaraid_sas-kmp-default-07.703.07.00_sles12sp2-1.x86_64.rpm | |
| ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | Part Number: 7Y37A01083 |
| deviceid: 1D490600 | |
| Required Firmware Update Package: lnvgy_fw_sraidmr_730-24.21.0-0016_linux_x86-64 | |
| Applicable RPM: lsi-megaraid_sas-kmp-default-07.703.07.00_sles12sp2-1.x86_64.rpm | |
| ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01084 |
| deviceid: 1D490601 | |
| ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01085 |
| deviceid: 1D490602 | |
| ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01086 |
| deviceid: 1D490603 | |
| ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01087 |
| deviceid: 1D490604 | |
| Required Firmware Update Package: lnvgy_fw_sraidmr35_930-50.3.0-1075_linux_x86-64 | |
| Applicable RPM: lsi-megaraid_sas-kmp-default-07.703.07.00_sles12sp2-1.x86_64.rpm | |
| ThinkSystem 430-8i SAS/SATA 12Gb HBA | Part Number: 7Y37A01088 |
| deviceid: 1D490200 | |
| ThinkSystem 430-16i SAS/SATA 12Gb HBA | Part Number: 7Y37A01089 |
| deviceid: 1D490201 | |
| ThinkSystem 430-8e SAS/SATA 12Gb HBA | Part Number: 7Y37A01090 |
| deviceid: 1D490202 | |
| Required Firmware Update Package: lnvgy_fw_mpt35sas_430-5.01-06_linux_x86-64 | |
| Applicable RPM: lsi-mpt3sas-kmp-default-24.125.01.00_sles12sp2-1.x86_64.rpm | |
| Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
| deviceid: 10DFE81C | |
| Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex | Part Number: 7ZT7A00493 |
| deviceid: 10DFE871 | |
| Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
| Applicable RPM: brcm-be2net-kmp-default-11.4.1241.0_4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Part Number: 00AG580 |
| deviceid: 10DFE81E | |
| Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
| Applicable RPM: brcmfcoe-vector-map-1-1.sles12sp2.x86_64.rpm | |
| Applicable RPM: brcm-brcmfcoe-kmp-default-11.4.1241.0_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Applicable RPM: brcm-be2iscsi-kmp-default-11.4.1223.0_4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Applicable RPM: brcm-be2net-kmp-default-11.4.1241.0_4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Intel X550-T1 Single Port 10GBase-T Adapter | Part Number: 00MM850 |
| deviceid: 80860021 | |
| Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
| deviceid: 80860022 | |
| ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | Part Number: 7ZT7A00533 |
| deviceid: 80860005 | |
| ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00534 |
| deviceid: 808600A2 | |
| ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 |
| deviceid: 808600A1 | |
| Intel X710-DA2 2x10GbE SFP+ adapter | Part Number: 7ZT7A00537 |
| deviceid: 8086000A | |
| Required Firmware Update Package: intc-lnvgy_fw_nic_6.36-3.5x-1.1824.0-f_linux_x86-64 | |
| Inbox Driver Supported | |
| ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00482 |
| deviceid: 17AA402c | |
| ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00484 |
| deviceid: 17AA402d | |
| Required Firmware Update Package: brcm-lnvgy_fw_nic_20.6.4.3a_linux_x86-64 | |
| Applicable RPM: broadcom-tg3-kmp-default-3.137q_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
| ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00496 |
| deviceid: 17AA0460 | |
| Required Firmware Update Package: brcm-lnvgy_fw_nic_nxe-20.06.04.07_linux_x86-64 | |
| Applicable RPM: bnxt_en-kmp-default-1.8.1_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
| deviceid: 10DFE333 | |
| Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
| deviceid: 10DFE332 | |
| Required Firmware Update Package: elx-lnvgy_fw_fc_17b-lp3x-11.4.168.16-3_linux_x86-64 | |
| Applicable RPM: elx-vector-map-1-1.sles12sp2.x86_64.rpm | |
| Applicable RPM: elx-lpfc-kmp-default-11.4.168.11_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
| QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Part Number: 01CV750 |
| deviceid: 107702AE | |
| QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Part Number: 01CV760 |
| deviceid: 107702AF | |
| Required Firmware Update Package: qlgc-lnvgy_fw_fc_1.90.43-2690-2742.p_linux_x86-64 | |
| Applicable RPM: qlgc-qla2xxx-kmp-default-8.07.00.51.12.2_k_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
| Repository RPM Listing | ||||
|---|---|---|---|---|
| RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
| bnxt_en-kmp-default-1.8.1_k4.4.21_69-1.sles12sp2.x86_64.rpm | bnxt_en-kmp-default | 1.8.1_k4.4.21_69 | 1.sles12sp2 | Broadcom NetXtreme Gigabit Ethernet and RoCE Driver |
| brcm-be2iscsi-kmp-default-11.4.1223.0_4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-be2iscsi-kmp-default | 11.4.1223.0_4.4.21_69 | 1.sles12sp2 | Emulex OneConnect Open-iSCSI Driver |
| brcm-be2net-kmp-default-11.4.1241.0_4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-be2net-kmp-default | 11.4.1241.0_4.4.21_69 | 1.sles12sp2 | Emulex NIC Driver |
| brcm-brcmfcoe-kmp-default-11.4.1241.0_k4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-brcmfcoe-kmp-default | 11.4.1241.0_k4.4.21_69 | 1.sles12sp2 | Broadcom - Emulex FCoE driver for Universal CNAs |
| brcmfcoe-vector-map-1-1.sles12sp2.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
| broadcom-tg3-kmp-default-3.137q_k4.4.21_69-1.sles12sp2.x86_64.rpm | broadcom-tg3-kmp-default | 3.137q_k4.4.21_69 | 1.sles12sp2 | Broadcom NetXtreme driver for Linux |
| elx-lpfc-kmp-default-11.4.168.11_k4.4.21_69-1.sles12sp2.x86_64.rpm | elx-lpfc-kmp-default | 11.4.168.11_k4.4.21_69 | 1.sles12sp2 | Emulex lpfc driver for Fibre Channel HBAs and Universal CNAs |
| elx-vector-map-1-1.sles12sp2.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
| lenovo-mgag200-kmp-default-sle12sp2_k4.4.21_69-1.2.x86_64.rpm | lenovo-mgag200-kmp-default | sle12sp2_k4.4.21_69 | 1.2 | Matrox mgag200 Driver |
| lsi-megaraid_sas-kmp-default-07.703.07.00_sles12sp2-1.x86_64.rpm | lsi-megaraid_sas-kmp-default | 07.703.07.00_k4.4.21_69 | 1 | LSI Megaraid_sas Driver Package |
| lsi-mpt3sas-kmp-default-24.125.01.00_sles12sp2-1.x86_64.rpm | lsi-mpt3sas-kmp-default | 24.125.01.00_k4.4.21_69 | 1 | LSI Fusion Kernel Module |
| qlgc-qla2xxx-kmp-default-8.07.00.51.12.2_k_k4.4.21_69-1.sles12sp2.x86_64.rpm | qlgc-qla2xxx-kmp-default | 8.07.00.51.12.2_k_k4.4.21_69 | 1.sles12sp2 | Linux driver for the QLogic FC adapter |
| Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
| linux.lenovo.com |