Lenovo YUM Repository
Targeted Server Family (Machine Type): System x3550 M5 (5463) |
Targeted Operating System: RHEL6.9 |
YUM Repository Build Date: 2018_05_31 |
Jump to RPM listing |
Suggested usage directions: |
1) Create a RHEL6.9 YUM repository configuration file named:
/etc/yum.repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
store: #cp RPM-GPG-KEY-LenovoYUM2018 /etc/pki/rpm-gpg/
| |
3) Install/Update Commands: | Initial INSTALL of updated drivers for specific device:#yum groupinstall deviceid
Find the deviceid for supported device below, muliple deviceid can be specified Initial INSTALL of updated drivers for ALL supported devices: #yum groupinstall LenovoUpdates
Install specific rpm: #yum install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #yum update after configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
Rack/Tower LOM | Part Number: NA |
---|---|
deviceid: 17AA400E | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nx1x-17.4.4.8-c_linux_x86-64 | |
Applicable RPM: kmod-tg3-3.137q-1.rhel6u9.x86_64.rpm | |
ServeRAID M1215 SAS/SATA Controller | Part Number: 46C9114 |
Required Firmware Update Package: lnvgy_fw_sraidmr_1200-24.21.0-0016-03_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | |
ServeRAID M5225-2GB SAS/SATA Controller | Part Number: 00AE938 |
ServeRAID M5210 SAS/SATA Controller | Part Number: 46C9110 |
Required Firmware Update Package: lnvgy_fw_sraidmr_5200-24.21.0-0020-02_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | |
N2225 SAS/SATA HBA | Part Number: 00AE912 |
N2226 SAS/SATA HBA | Part Number: 00AE916 |
N2215 SAS/SATA HBA | Part Number: 47C8675 |
Required Firmware Update Package: lnvgy_fw_mpt3sas_n2200-1.15-5_linux_x86-64 | |
Applicable RPM: kmod-mpt3sas-24.125.01.00_el6.9-1.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
Applicable RPM: kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | Part Number: 00AG560 |
deviceid: 10DFE81F | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Part Number: 00AG580 |
deviceid: 10DFE81E | |
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter | Part Number: 00D1996 |
deviceid: 10DFE810 | |
Emulex 10 GbE Virtual Fabric Adapter 5 Standard | Part Number: 00JY820 |
deviceid: 10DFE816 | |
Emulex 10 GbE Virtual Fabric Adapter 5 Plus | Part Number: 00JY830 |
deviceid: 10DFE818 | |
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE | Part Number: 01CV770 |
deviceid: 10DFE874 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18a-oc14-11.4.1241.10-1_linux_x86-64 | |
Applicable RPM: brcmfcoe-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-brcmfcoe-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2iscsi-11.4.1223.0-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | |
Mellanox ConnectX-3 FDR VPI IB/E Adapter | Part Number: 00D9550 |
deviceid: 15B30076 | |
Mellanox ConnectX- 3 10 GbE Adapter | Part Number: 00D9690 |
deviceid: 15B30077 | |
Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter | Part Number: 00FP650 |
deviceid: 15B30032 | |
Required Firmware Update Package: mlnx-lnvgy_fw_nic_4.1-1.0.2.2_linux_x86-64 | |
Applicable RPM: mlnx-en-utils-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-mlnx-en-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | |
Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter | Part Number: 00MM950 |
deviceid: 15B30018 | |
Mellanox ConnectX-4 2x100GbE / EDR IB QSFP28 VPI Adapter | Part Number: 00MM960 |
deviceid: 15B30055 | |
Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter | Part Number: 00MN990 |
deviceid: 15B30056 | |
Mellanox ConnectX-4 Lx 2x25GbE PCIe Adapter | Part Number: 01GR250 |
deviceid: 15B30057 | |
Required Firmware Update Package: mlnx-lnvgy_fw_nic_4.1-1.0.2.2_linux_x86-64 | |
Applicable RPM: mlnx-en-utils-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-mlnx-en-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | |
Broadcom NetXtreme II ML2 Dual Port 10GbaseT for IBM System x | Part Number: 00D2026 |
deviceid: 101404A1 | |
Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for IBM System x | Part Number: 00D2028 |
deviceid: 101404A0 | |
Broadcom NetXtreme Dual Port 10GbE BastT Adapter for IBM System x | Part Number: 44T1370 |
deviceid: 10140492 | |
Broadcom Dual Port 10GbE SFP+ Adapter for IBM System x | Part Number: 94Y5180 |
deviceid: 101404C6 | |
Required Firmware Update Package: qlgc-lnvgy_fw_nic_20.17b.08.22b_linux_x86-64 | |
Applicable RPM: kmod-netxtreme2-7.14.29-1.rhel6u9.x86_64.rpm | |
Intel I350-F1 1xGbE Fiber Adapter | Part Number: 00AG500 |
deviceid: 80860005 | |
Intel I350-T2 2xGbE BaseT Adapter for IBM System x | Part Number: 00AG510 |
deviceid: 808600A2 | |
Intel I350-T4 4xGbE BaseT Adapter for IBM System x | Part Number: 00AG520 |
deviceid: 808600A1 | |
Intel X540 ML2 Dual Port 10GbaseT Adapter for IBM System x | Part Number: 00D1994 |
deviceid: 80860000 | |
Intel I350-T4 ML2 Quad Port GbE Adapter for IBM System x | Part Number: 00D1998 |
deviceid: 80861521 | |
Intel X710-DA2 ML2 2x10GbE SFP+ adapter | Part Number: 00JY940 |
deviceid: 8086000D | |
Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
deviceid: 80860022 | |
Intel X710 2x10GbE SFP+ Adapter for IBM System x | Part Number: 01DA900 |
deviceid: 8086000A | |
Intel X520-DA2 Dual Port 10GbE SFP+ Adapter for IBM System x | Part Number: 49Y7960 |
deviceid: 80867A12 | |
Intel X540-T2 Dual Port 10GBase-T Adapter for IBM System x | Part Number: 49Y7970 |
deviceid: 8086001A | |
Intel X710-DA2 2x10GbE SFP+ adapter | Part Number: 7ZT7A00537 |
deviceid: 8086000A | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.36-3.5x-1.1824.0-f_linux_x86-64 | |
Applicable RPM: kmod-ixgbe-5.3.3-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40e-2.3.6-1.el6.x86_64.rpm | |
Applicable RPM: kmod-igb-5.3.5.12-1.x86_64.rpm | |
Applicable RPM: kmod-ixgbevf-4.3.2-1.el6.x86_64.rpm | |
Applicable RPM: kmod-i40evf-3.2.5-1.el6.x86_64.rpm | |
Broadcom NetXtreme I Quad Port GbE Adapter | Part Number: 90Y9352 |
deviceid: 10140420 | |
Broadcom NetXtreme I Dual Port GbE Adapter | Part Number: 90Y9370 |
deviceid: 10140450 | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nx1x-17.4.4.8-c_linux_x86-64 | |
Applicable RPM: kmod-tg3-3.137q-1.rhel6u9.x86_64.rpm | |
Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
deviceid: 10DFE333 | |
Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
deviceid: 10DFE332 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-lp3x-11.4.168.16-3_linux_x86-64 | |
Applicable RPM: elx-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | |
Emulex 16Gb FC Single-port HBA | Part Number: 81Y1655 |
deviceid: 10DFE203 | |
Emulex 16Gb FC Dual-port HBA | Part Number: 81Y1662 |
deviceid: 10DFE204 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-lp16-11.4.168.11-5_linux_x86-64 | |
Applicable RPM: elx-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | |
Emulex 8Gb FC Single-port HBA | Part Number: 42D0485 |
deviceid: 10DFF100 | |
Emulex 8Gb FC Dual-port HBA | Part Number: 42D0494 |
deviceid: 10DFF100 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_17b-2.03x14-21_linux_x86-64 | |
Applicable RPM: elx-vector-map-1-1.rhel6u9.x86_64.rpm | |
Applicable RPM: kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | |
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Part Number: 01CV750 |
deviceid: 107702AE | |
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Part Number: 01CV760 |
deviceid: 107702AF | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_1.90.43-2690-2742.p_linux_x86-64 | |
Applicable RPM: kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | |
Qlogic 16Gb FC Single-port HBA for IBM System x | Part Number: 00Y3337 |
deviceid: 10770264 | |
Qlogic 16Gb FC Dual-port HBA for IBM System x | Part Number: 00Y3341 |
deviceid: 10770263 | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_266x-4.74.10.l_linux_x86-64 | |
Applicable RPM: kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | |
QLogic 8Gb FC Single-port HBA for IBM System x | Part Number: 42D0501 |
deviceid: 1077015C | |
QLogic 8Gb FC Dual-port HBA for IBM System x | Part Number: 42D0510 |
deviceid: 1077015D | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_8g-mb4.10.06.k_linux_x86-64 | |
Applicable RPM: kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | |
Repository RPM Listing | ||||
---|---|---|---|---|
RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
brcmfcoe-vector-map-1-1.rhel6u9.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
elx-vector-map-1-1.rhel6u9.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
kmod-brcm-be2iscsi-11.4.1223.0-1.rhel6u9.x86_64.rpm | kmod-brcm-be2iscsi | 11.4.1223.0 | 1.rhel6u9 | brcm-be2iscsi kernel module(s) |
kmod-brcm-be2net-11.4.1241.0-1.rhel6u9.x86_64.rpm | kmod-brcm-be2net | 11.4.1241.0 | 1.rhel6u9 | brcm-be2net kernel module(s) |
kmod-brcm-brcmfcoe-11.4.1241.0-1.rhel6u9.x86_64.rpm | kmod-brcm-brcmfcoe | 11.4.1241.0 | 1.rhel6u9 | brcm-brcmfcoe kernel module(s) |
kmod-elx-lpfc-11.4.168.11-1.rhel6u9.x86_64.rpm | kmod-elx-lpfc | 11.4.168.11 | 1.rhel6u9 | elx-lpfc kernel module(s) |
kmod-i40e-2.3.6-1.el6.x86_64.rpm | kmod-i40e | 2.3.6 | 1.el6 | i40e kernel module(s) |
kmod-i40evf-3.2.5-1.el6.x86_64.rpm | kmod-i40evf | 3.2.5 | 1.el6 | i40evf kernel module(s) |
kmod-igb-5.3.5.12-1.x86_64.rpm | kmod-igb | 5.3.5.12 | 1 | igb kernel module(s) |
kmod-ixgbe-5.3.3-1.el6.x86_64.rpm | kmod-ixgbe | 5.3.3 | 1.el6 | ixgbe kernel module(s) |
kmod-ixgbevf-4.3.2-1.el6.x86_64.rpm | kmod-ixgbevf | 4.3.2 | 1.el6 | ixgbevf kernel module(s) |
kmod-megaraid_sas-07.703.07.00_el6.9-1.x86_64.rpm | kmod-megaraid_sas | 07.703.07.00_el6.9 | 1 | megaraid_sas kernel module(s) |
kmod-mlnx-en-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | kmod-mlnx-en | 4.1 | 1.0.2.0.gc22af88.rhel6u9 | mlnx-en kernel module(s) |
kmod-mpt3sas-24.125.01.00_el6.9-1.x86_64.rpm | kmod-mpt3sas | 24.125.01.00_el6.9 | 1 | mpt3sas kernel module(s) |
kmod-netxtreme2-7.14.29-1.rhel6u9.x86_64.rpm | kmod-netxtreme2 | 7.14.29 | 1.rhel6u9 | netxtreme2 kernel module(s) |
kmod-qlgc-qla2xxx-8.07.00.51.06.0_k-1.rhel6u9.x86_64.rpm | kmod-qlgc-qla2xxx | 8.07.00.51.06.0_k | 1.rhel6u9 | qlgc-qla2xxx kernel module(s) |
kmod-tg3-3.137q-1.rhel6u9.x86_64.rpm | kmod-tg3 | 3.137q | 1.rhel6u9 | tg3 kernel module(s) |
mlnx-en-utils-4.1-1.0.2.0.gc22af88.rhel6u9.x86_64.rpm | mlnx-en-utils | 4.1 | 1.0.2.0.gc22af88.rhel6u9 | Utilities for the Mellanox Ethernet Driver for Linux |
Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |