Lenovo YUM Repository
Targeted Server Family (Machine Type): ThinkSystem SR550 (7X03,7X04) |
Targeted Operating System: SLES12SP2 |
YUM Repository Build Date: 2018_09_19 |
Jump to RPM listing |
Suggested usage directions: |
1) Create a SLES12SP2 YUM repository configuration file named:
/etc/zypp/repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
| |
3) Install/Update Commands: | Initial INSTALL of updated drivers for ALL supported devices:#zypper install --from lenovo '*'
Install specific rpm: #zypper install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #zypper update after configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
MotherBoard Video | Part Number: NA |
---|---|
Applicable RPM: lenovo-mgag200-kmp-default-sle12sp2_k4.4.21_69-1.2.x86_64.rpm | |
ThinkSystem 1Gb 2-port RJ45 LOM | Part Number: 7ZT7A00544 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port SFP+ LOM | Part Number: 7ZT7A00546 |
deviceid: 17AA4020 | |
ThinkSystem 10Gb 2-port Base-T LOM | Part Number: 7ZT7A00548 |
deviceid: 17AA4020 | |
ThinkSystem SR530/550 LOM | Part Number: NA |
deviceid: 17AA4022 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Inbox Driver Supported | |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | Part Number: 7Y37A01082 |
deviceid: 1D490500 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_530-50.5.0-1678_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.705.05.00_sles12sp2-1.x86_64.rpm | |
ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 4Y37A09722 |
deviceid: 1D490608 | |
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | Part Number: 7Y37A01083 |
deviceid: 1D490600 | |
Required Firmware Update Package: lnvgy_fw_sraidmr_730-24.21.0-0067-2_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.705.05.00_sles12sp2-1.x86_64.rpm | |
ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter | Part Number: 4Y37A09721 |
deviceid: 1D490607 | |
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01084 |
deviceid: 1D490601 | |
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01085 |
deviceid: 1D490602 | |
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | Part Number: 7Y37A01087 |
deviceid: 1D490604 | |
Required Firmware Update Package: lnvgy_fw_sraidmr35_930-50.5.0-1678_linux_x86-64 | |
Applicable RPM: lsi-megaraid_sas-kmp-default-07.705.05.00_sles12sp2-1.x86_64.rpm | |
ThinkSystem 430-8i SAS/SATA 12Gb HBA | Part Number: 7Y37A01088 |
deviceid: 1D490200 | |
ThinkSystem 430-16i SAS/SATA 12Gb HBA | Part Number: 7Y37A01089 |
deviceid: 1D490201 | |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | Part Number: 7Y37A01090 |
deviceid: 1D490202 | |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | Part Number: 7Y37A01091 |
deviceid: 1D490203 | |
Required Firmware Update Package: lnvgy_fw_mpt35sas_430-06.02.00.01_linux_x86-64 | |
Applicable RPM: lsi-mpt3sas-kmp-default-25.125.02.00_sles12sp2-1.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Lenovo ThinkSystem OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter By Emulex | Part Number: 7ZT7A00493 |
deviceid: 10DFE871 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18b-oc14-12.0.1169.12-2_linux_x86-64 | |
Applicable RPM: brcm-be2net-kmp-default-debuginfo-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcm-be2net-kmp-default-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | |
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | Part Number: 00AG560 |
deviceid: 10DFE81F | |
Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | Part Number: 00AG580 |
deviceid: 10DFE81E | |
Emulex VFA5.2 ML2 2Port10GbE SFP+ Adapter w/FCoE | Part Number: 01CV770 |
deviceid: 10DFE874 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18b-oc14-12.0.1169.12-2_linux_x86-64 | |
Applicable RPM: brcm-brcmfcoe-kmp-default-debuginfo-12.0.1169.7_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcmfcoe-vector-map-1-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcm-brcmfcoe-kmp-default-12.0.1169.7_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcm-be2iscsi-kmp-default-12.0.1161.0_4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcm-be2net-kmp-default-debuginfo-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: brcm-be2net-kmp-default-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | |
ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter | Part Number: 4XC7A08225 |
deviceid: 10770039 | |
Required Firmware Update Package: qlgc-lnvgy_fw_nic_ah-8.35.47-1_linux_x86-64 | |
Applicable RPM: qlgc-fastlinq-kmp-default-8.37.18.0_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: qlgc-libqedr-8.37.0.0-1.sles12sp2.x86_64.rpm | |
Intel X710-DA2 ML2 2x10GbE SFP+ Adapter | Part Number: 00JY940 |
deviceid: 8086000D | |
Intel X710-DA2 2x10GbE SFP+ Adapter | Part Number: 7ZT7A00537 |
deviceid: 8086000A | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Inbox Driver Supported | |
Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
deviceid: 80860022 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Inbox Driver Supported | |
ThinkSystem Intel I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | Part Number: 7ZT7A00533 |
deviceid: 80860005 | |
ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00534 |
deviceid: 808600A2 | |
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 |
deviceid: 808600A1 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Inbox Driver Supported | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00482 |
deviceid: 17AA402C | |
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00484 |
deviceid: 17AA402D | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nx1-212.0.5.4_linux_x86-64 | |
Applicable RPM: broadcom-tg3-kmp-default-3.137x_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00496 |
deviceid: 17AA0460 | |
ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter | Part Number: 7ZT7A00497 |
deviceid: 17AA4161 | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nxe-212.0.168.0_linux_x86-64 | |
Applicable RPM: broadcom-bnxt_en-kmp-default-1.9.1.212.0.162.0_k4.4.21_69-100R.7.1.x86_64.rpm | |
Applicable RPM: broadcom-bnxt_en-kmp-default-debuginfo-1.9.1.212.0.162.0_k4.4.21_69-100R.7.1.x86_64.rpm | |
Applicable RPM: libbnxtre-212.0.159.0-sles12sp2.x86_64.rpm | |
Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
deviceid: 10DFE333 | |
Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
deviceid: 10DFE332 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_18a-lp3x-11.4.329.13-7_linux_x86-64 | |
Applicable RPM: elx-lpfc-kmp-default-11.4.142.28_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: elx-vector-map-1-1.sles12sp2.x86_64.rpm | |
Emulex 8Gb FC Single-port HBA | Part Number: 4XC7A08220 |
deviceid: 10DFF140 | |
Emulex 8Gb FC Dual-port HBA | Part Number: 4XC7A08221 |
deviceid: 10DFF141 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_18a-2.10x6-9_linux_x86-64 | |
Applicable RPM: elx-lpfc-kmp-default-11.4.142.28_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Applicable RPM: elx-vector-map-1-1.sles12sp2.x86_64.rpm | |
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Part Number: 01CV750 |
deviceid: 107702AE | |
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Part Number: 01CV760 |
deviceid: 107702AF | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_1.90.53-2690-2742.d_linux_x86-64 | |
Applicable RPM: qlgc-qla2xxx-kmp-default-8.08.00.08.12.2_k_k4.4.21_69-1.sles12sp2.x86_64.rpm | |
Repository RPM Listing | ||||
---|---|---|---|---|
RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
brcm-be2iscsi-kmp-default-12.0.1161.0_4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-be2iscsi-kmp-default | 12.0.1161.0_4.4.21_69 | 1.sles12sp2 | Emulex OneConnect Open-iSCSI Driver |
brcm-be2net-kmp-default-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-be2net-kmp-default | 12.0.1169.3_4.4.21_69 | 1.sles12sp2 | Emulex NIC Driver |
brcm-be2net-kmp-default-debuginfo-12.0.1169.3_4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-be2net-kmp-default-debuginfo | 12.0.1169.3_4.4.21_69 | 1.sles12sp2 | Debug information for package brcm-be2net-kmp-default |
brcm-brcmfcoe-kmp-default-12.0.1169.7_k4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-brcmfcoe-kmp-default | 12.0.1169.7_k4.4.21_69 | 1.sles12sp2 | Debug sources for package brcm-brcmfcoe |
brcm-brcmfcoe-kmp-default-debuginfo-12.0.1169.7_k4.4.21_69-1.sles12sp2.x86_64.rpm | brcm-brcmfcoe-kmp-default-debuginfo | 12.0.1169.7_k4.4.21_69 | 1.sles12sp2 | Debug information for package brcm-brcmfcoe-kmp-default |
brcmfcoe-vector-map-1-1.sles12sp2.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
broadcom-bnxt_en-kmp-default-1.9.1.212.0.162.0_k4.4.21_69-100R.7.1.x86_64.rpm | broadcom-bnxt_en-kmp-default | 1.9.1.212.0.162.0_k4.4.21_69 | 100R.7.1 | Broadcom NetXtreme Gigabit Ethernet and RoCE Driver |
broadcom-bnxt_en-kmp-default-debuginfo-1.9.1.212.0.162.0_k4.4.21_69-100R.7.1.x86_64.rpm | broadcom-bnxt_en-kmp-default-debuginfo | 1.9.1.212.0.162.0_k4.4.21_69 | 100R.7.1 | Debug information for package broadcom-bnxt_en-kmp-default |
broadcom-tg3-kmp-default-3.137x_k4.4.21_69-1.sles12sp2.x86_64.rpm | broadcom-tg3-kmp-default | 3.137x_k4.4.21_69 | 1.sles12sp2 | Broadcom NetXtreme driver for Linux |
elx-lpfc-kmp-default-11.4.142.28_k4.4.21_69-1.sles12sp2.x86_64.rpm | elx-lpfc-kmp-default | 11.4.142.28_k4.4.21_69 | 1.sles12sp2 | Emulex lpfc driver for Fibre Channel HBAs and Universal CNAs |
elx-vector-map-1-1.sles12sp2.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
lenovo-mgag200-kmp-default-sle12sp2_k4.4.21_69-1.2.x86_64.rpm | lenovo-mgag200-kmp-default | sle12sp2_k4.4.21_69 | 1.2 | Matrox mgag200 Driver |
libbnxtre-212.0.159.0-sles12sp2.x86_64.rpm | libbnxtre | 212.0.159.0 | sles12sp2 | Userspace Library for Broadcom ROCE Device. |
lsi-megaraid_sas-kmp-default-07.705.05.00_sles12sp2-1.x86_64.rpm | lsi-megaraid_sas-kmp-default | 07.705.05.00_k4.4.21_69 | 1 | LSI Megaraid_sas Driver Package |
lsi-mpt3sas-kmp-default-25.125.02.00_sles12sp2-1.x86_64.rpm | lsi-mpt3sas-kmp-default | 25.125.02.00_k4.4.21_69 | 1 | LSI Fusion MPT Kernel Module Package |
qlgc-fastlinq-kmp-default-8.37.18.0_k4.4.21_69-1.sles12sp2.x86_64.rpm | qlgc-fastlinq-kmp-default | 8.37.18.0_k4.4.21_69 | 1.sles12sp2 | QLogic fastlinq CNA drivers |
qlgc-libqedr-8.37.0.0-1.sles12sp2.x86_64.rpm | qlgc-libqedr | 8.37.0.0 | 1.sles12sp2 | QLogic libqedr libraries |
qlgc-qla2xxx-kmp-default-8.08.00.08.12.2_k_k4.4.21_69-1.sles12sp2.x86_64.rpm | qlgc-qla2xxx-kmp-default | 8.08.00.08.12.2_k_k4.4.21_69 | 1.sles12sp2 | Linux driver for the QLogic FC adapter |
Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |