Lenovo YUM Repository
Targeted Server Family (Machine Type): System x3250 M6 (3633,3943) |
Targeted Operating System: RHEL7.4 |
YUM Repository Build Date: 2018_09_19 |
Jump to RPM listing |
Suggested usage directions: |
1) Create a RHEL7.4 YUM repository configuration file named:
/etc/yum.repos.d/lenovo.repo Suggested file contents: |
[lenovo]
| |
2) Download/install Public Signing Key
Commands: |
Download key - Two opitions (choose only one):
Option 1 (Prefered, most secure - Download key from lenovo.com) #curl https://download.lenovo.com/servers_pdf/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
Option 2 (Less secure - Install key from stored within Repository) #curl {uri from repos creation step}/repodata/RPM-GPG-KEY-LenovoYUM2018 > RPM-GPG-KEY-LenovoYUM2018
check: #gpg --quiet --with-fingerprint ./RPM-GPG-KEY-LenovoYUM2018
Expected Output:
import: #rpm --import RPM-GPG-KEY-LenovoYUM2018
store: #cp RPM-GPG-KEY-LenovoYUM2018 /etc/pki/rpm-gpg/
| |
3) Install/Update Commands: | Initial INSTALL of updated drivers for specific device:#yum groupinstall deviceid
Find the deviceid for supported device below, muliple deviceid can be specified Initial INSTALL of updated drivers for ALL supported devices: #yum groupinstall LenovoUpdates
Install specific rpm: #yum install rpm_name
Specific rpms associated to specific devices are listed below, muliple rpms can be specified in single command After install of deviceid groups(s) or rpm(s), use: #yum update after configuring server to use update repository Where specified in table below, device firmware must be updated to suggested levels |
System x3250 LOM | Part Number: NA |
---|---|
deviceid: 17AA4016 | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18b-oc14-12.0.1169.12-2_linux_x86-64 | |
Applicable RPM: brcmfcoe-vector-map-1-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-brcmfcoe-12.0.1154.3-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2iscsi-12.0.1154.2-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2net-12.0.1154.1-1.rhel7u4.x86_64.rpm | |
ServeRAID M1210 SAS/SATA Controller | Part Number: 00JY194 |
deviceid: 1D4904DB | |
ServeRAID M1215 SAS/SATA Controller | Part Number: 46C9114 |
deviceid: 10140456 | |
Required Firmware Update Package: lnvgy_fw_sraidmr_1200-24.21.0-0067-1_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.705.05.00_el7.4-1.x86_64.rpm | |
ServeRAID M5225-2GB SAS/SATA Controller | Part Number: 00AE938 |
deviceid: 10410455 | |
ServeRAID M5210 SAS/SATA Controller | Part Number: 46C9110 |
deviceid: 10140454 | |
Required Firmware Update Package: lnvgy_fw_sraidmr_5200-24.21.0-0067-1_linux_x86-64 | |
Applicable RPM: kmod-megaraid_sas-07.705.05.00_el7.4-1.x86_64.rpm | |
N2225 SAS/SATA HBA | Part Number: 00AE912 |
deviceid: 101404BE | |
N2215 SAS/SATA HBA | Part Number: 47C8675 |
deviceid: 10140457 | |
Required Firmware Update Package: lnvgy_fw_mpt3sas_n2200-1.15-7_linux_x86-64 | |
Applicable RPM: kmod-mpt3sas-25.125.02.00_el7.4-1.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18b-oc14-12.0.1169.12-2_linux_x86-64 | |
Applicable RPM: kmod-brcm-be2net-12.0.1154.1-1.rhel7u4.x86_64.rpm | |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter (iSCSI+FCoE Enabled) | Part Number: 00AG570 |
deviceid: 10DFE81C | |
Required Firmware Update Package: brcm-lnvgy_fw_cna_18b-oc14-12.0.1169.12-2_linux_x86-64 | |
Applicable RPM: brcmfcoe-vector-map-1-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-brcmfcoe-12.0.1154.3-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2iscsi-12.0.1154.2-1.rhel7u4.x86_64.rpm | |
Applicable RPM: kmod-brcm-be2net-12.0.1154.1-1.rhel7u4.x86_64.rpm | |
Intel X710 2x10GbE SFP+ Adapter for IBM System x | Part Number: 01DA900 |
deviceid: 8086000A | |
Intel X710-T4 PCIe 4x10Gb RJ45 Adapter | Part Number: 7XC7A05927 |
deviceid: 808600A0 | |
Intel X710-DA2 2x10GbE SFP+ Adapter | Part Number: 7ZT7A00537 |
deviceid: 8086000A | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Applicable RPM: kmod-i40e-2.4.6.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-ixgbe-5.3.5.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-i40evf-3.5.6.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-ixgbevf-4.3.3.1-1.el7.x86_64.rpm | |
Intel X550-T2 Dual Port 10GBase-T Adapter | Part Number: 00MM860 |
deviceid: 80860022 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Applicable RPM: kmod-i40e-2.4.6.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-ixgbe-5.3.5.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-i40evf-3.5.6.1-1.el7.x86_64.rpm | |
Applicable RPM: kmod-ixgbevf-4.3.3.1-1.el7.x86_64.rpm | |
Intel I350-T2 2xGbE BaseT Adapter for IBM System x | Part Number: 00AG510 |
deviceid: 808600A2 | |
Intel I350-T4 4xGbE BaseT Adapter for IBM System x | Part Number: 00AG520 |
deviceid: 808600A1 | |
Required Firmware Update Package: intc-lnvgy_fw_nic_6.80-4.00-1.1937.0-e_linux_x86-64 | |
Inbox Driver Supported | |
Broadcom NetXtreme I Dual Port GbE Adapter | Part Number: 90Y9370 |
deviceid: 10140450 | |
Required Firmware Update Package: brcm-lnvgy_fw_nic_nx1-212.0.5.4_linux_x86-64 | |
Applicable RPM: kmod-tg3-3.137x-1.rhel7u4.x86_64.rpm | |
Emulex 16Gb Gen6 FC Single-port HBA | Part Number: 01CV830 |
deviceid: 10DFE333 | |
Emulex 16Gb Gen6 FC Dual-port HBA | Part Number: 01CV840 |
deviceid: 10DFE332 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_18a-lp3x-11.4.329.13-7_linux_x86-64 | |
Applicable RPM: kmod-elx-lpfc-11.4.329.40-1.rhel7u4.x86_64.rpm | |
Applicable RPM: elx-vector-map-1-1.rhel7u4.x86_64.rpm | |
Emulex 16Gb FC Single-port HBA | Part Number: 81Y1655 |
deviceid: 10DFE203 | |
Emulex 16Gb FC Dual-port HBA | Part Number: 81Y1662 |
deviceid: 10DFE204 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_18a-lp16-11.4.329.13-7_linux_x86-64 | |
Applicable RPM: kmod-elx-lpfc-11.4.329.40-1.rhel7u4.x86_64.rpm | |
Applicable RPM: elx-vector-map-1-1.rhel7u4.x86_64.rpm | |
Emulex 8Gb FC Single-port HBA | Part Number: 42D0485 |
deviceid: 10DFF100 | |
Emulex 8Gb FC Dual-port HBA | Part Number: 42D0494 |
deviceid: 10DFF100 | |
Required Firmware Update Package: elx-lnvgy_fw_fc_18a-2.10x6-9_linux_x86-64 | |
Applicable RPM: kmod-elx-lpfc-11.4.329.40-1.rhel7u4.x86_64.rpm | |
Applicable RPM: elx-vector-map-1-1.rhel7u4.x86_64.rpm | |
QLogic 8Gb FC Single-port HBA for IBM System x | Part Number: 42D0501 |
deviceid: 1077015C | |
QLogic 8Gb FC Dual-port HBA for IBM System x | Part Number: 42D0510 |
deviceid: 1077015D | |
Required Firmware Update Package: qlgc-lnvgy_fw_fc_8g-mb4.10.08.c_linux_x86-64 | |
Applicable RPM: kmod-qlgc-qla2xxx-8.08.00.08.07.0_k-1.rhel7u4.x86_64.rpm | |
Repository RPM Listing | ||||
---|---|---|---|---|
RPM file Name | RPMdb Name | RPM version number | RPM release number | RPM summary |
brcmfcoe-vector-map-1-1.rhel7u4.x86_64.rpm | brcmfcoe-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
elx-vector-map-1-1.rhel7u4.x86_64.rpm | elx-lpfc-vector-map | 1 | 1 | Emulex I/O Channel to CPU Load Balancing and Optimized Access package |
kmod-brcm-be2iscsi-12.0.1154.2-1.rhel7u4.x86_64.rpm | kmod-brcm-be2iscsi | 12.0.1154.2 | 1.rhel7u4 | brcm-be2iscsi kernel module(s) |
kmod-brcm-be2net-12.0.1154.1-1.rhel7u4.x86_64.rpm | kmod-brcm-be2net | 12.0.1154.1 | 1.rhel7u4 | brcm-be2net kernel module(s) |
kmod-brcm-brcmfcoe-12.0.1154.3-1.rhel7u4.x86_64.rpm | kmod-brcm-brcmfcoe | 12.0.1154.3 | 1.rhel7u4 | brcm-brcmfcoe kernel module(s) |
kmod-elx-lpfc-11.4.329.40-1.rhel7u4.x86_64.rpm | kmod-elx-lpfc | 11.4.329.40 | 1.rhel7u4 | elx-lpfc kernel module(s) |
kmod-i40e-2.4.6.1-1.el7.x86_64.rpm | kmod-i40e | 2.4.6.1 | 1.el7 | i40e kernel module(s) |
kmod-i40evf-3.5.6.1-1.el7.x86_64.rpm | kmod-i40evf | 3.5.6.1 | 1.el7 | i40evf kernel module(s) |
kmod-ixgbe-5.3.5.1-1.el7.x86_64.rpm | kmod-ixgbe | 5.3.5.1 | 1.el7 | ixgbe kernel module(s) |
kmod-ixgbevf-4.3.3.1-1.el7.x86_64.rpm | kmod-ixgbevf | 4.3.3.1 | 1.el7 | ixgbevf kernel module(s) |
kmod-megaraid_sas-07.705.05.00_el7.4-1.x86_64.rpm | kmod-megaraid_sas | 07.705.05.00_el7.4 | 1 | megaraid_sas kernel module(s) |
kmod-mpt3sas-25.125.02.00_el7.4-1.x86_64.rpm | kmod-mpt3sas | 25.125.02.00_el7.4 | 1 | mpt3sas kernel module(s) |
kmod-qlgc-qla2xxx-8.08.00.08.07.0_k-1.rhel7u4.x86_64.rpm | kmod-qlgc-qla2xxx | 8.08.00.08.07.0_k | 1.rhel7u4 | qlgc-qla2xxx kernel module(s) |
kmod-tg3-3.137x-1.rhel7u4.x86_64.rpm | kmod-tg3 | 3.137x | 1.rhel7u4 | tg3 kernel module(s) |
Lenovo Service and Support: |
|
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |