Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SR550 (7X03, 7X04)
Targeted Operating System: RHEL6.9
YUM Repository Build Date: 2019_04_23

YUM Repository Release Version: 19A

Device:
ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter

Device Product Guide

Part Number: 7ZT7A00484
Feature Code: AUZX
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x402D


Release History:
Release: 19A
Change History Documents
Firmware Firmware Name Version
Unknown OSS reteival error nx1-212.0.5.4
Drivers Driver Name Discreate Package Download Version
tg3
  kernel driver
kmod-tg3-3.137x-1.rhel6u9.x86_64.rpm 3.137x

Release: 18D
Firmware Firmware Name Version
Unknown OSS reteival error nx1-212.0.5.4
Drivers Driver Name Discreate Package Download Version
tg3
  kernel driver
kmod-tg3-3.137x-1.rhel6u9.x86_64.rpm 3.137x

Release: 18B
Firmware Firmware Name Version
Unknown OSS reteival error nx1-212.0.4.3
Drivers Driver Name Discreate Package Download Version
tg3
  kernel driver
kmod-tg3-3.137w-2.rhel6u9.x86_64.rpm 3.137w


Release 19A Change History Documents

Unknown OSS reteival error



===============================================================================
                     Broadcom Netxtreme Firmware Package
===============================================================================

Firmware Version: 212.0.5.4

This package updates the Broadcom Firmware Code to the levels shown under the
"Version" column for the products listed below :

ThinkSystem Adapters / LOMs                                             ASIC
----------------------------------------                                -----
ThinkSystem SR150/SR158 / SR250/SR258 / ST250/ST258                     5720
Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter (7ZT7A00482)   5720
Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter (7ZT7A00484)   5719

System x Adapters / LOMs                                                ASIC
----------------------------------------                                -----
System x3650 M5 / x3550 M5 / x3500 M5                                   5719
NeXtScale nx360 M5                                                      5717_C0
Broadcom NetXtreme I Dual Port GbE Adapter     (90Y9370)                5720
Flex System EN2024 4-port 1Gb Ethernet Adapter (49Y7900)                5718
Broadcom NetXtreme I Quad Port GbE Adapter     (90Y9352)                5719

===============================================================================
Change History
===============================================================================

Firmware Version: 212.0.5.4
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.47
      5720          1.39

    ThinkSystem Adapters / LOMs
    -----------------------------

    PXE Code        20.6.1
    UEFI Code       20.12.9
    ISCSI Code      212.0.12
    NCSI Code       1.4.26
    MGMT_FW Code    1.12

    System x Adapters / LOMs
    -----------------------------

    PXE Code        20.6.1
    UEFI Code       17.4.9
    ISCSI Code      212.0.12
    NCSI Code       1.4.26
    MGMT_FW Code    1.12

    Problems Fixed:
      - Rolled back legacy PXE Code to the level contained in package 20.6.4.3a
        (20.6.1). The level contained in package 212.0.4.3 (20.6.50) uses much  
        more conventional memory, which can cause other devices like storage 
        adapters to run out of resources. These are functionally equivalent.
      - Updated NCSI Code to: 
         - Fix an issue where 5719 ASIC ports 3 and 4 do not go into WOL mode 
           when AC power is first applied
      - Updated ThinkSystem UEFI code to:
         - Fix several configuration options which had no default value
         - Add a 'Firmware Bundle' version to the Firmware Image Menu in F1 setup
      - Updated the firmware update utility to: 
         - Fix a failure to update firmware under SLES 15
         - Fix a failure where the update stops with a "file is too big" error

===============================================================================
===============================================================================

Firmware Version: 212.0.4.3
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.47
      5720          1.39

    ThinkSystem Adapters / LOMs
    -----------------------------

    PXE Code        20.6.50
    UEFI Code       20.12.4
    ISCSI Code      212.0.12
    NCSI Code       1.4.22
    MGMT_FW Code    1.12

    System x Adapters / LOMs
    -----------------------------

    PXE Code        20.6.50
    UEFI Code       17.4.9
    ISCSI Code      212.0.12
    NCSI Code       1.4.22
    MGMT_FW Code    1.12

    Problems Fixed:

      - Updated firmware update utility to: 
        - Support SLES15
        - Disable check for Fcode allowing removal if needed.
        - Enable logging for command line mode.
      - Updated UEFI UNDI driver to:
        - Fix the individual port enable/disable setting that is visible for 
          BCM5719 LOMs/NICS in F1 setup. Settings changes were not being saved 
          in ThinkSystem machines
        - Fix a potential incompatibility with newer system UEFI levels, a hang
          will occur while attempting to UEFI PXE boot.  Newer levels of system
          UEFI no longer enable busmaster enable bit in PCI configuration space
        - Add the adapter port MAC address to the listing in F1 setup Network menu
       
    Enhancements:   

      - Combined firmware package for both ThinkSystem and System x products

===============================================================================
===============================================================================

Firmware Version: 20.6.4.3a
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5719          1.47
      5720          1.39

    ThinkSystem Adapters / LOMs
    ---------------------------
    UEFI Code       20.6.13
    PXE Code        20.6.1  
    ISCSI Code      20.6.2 

    Problems Fixed:
       
    Enhancements:   

       - Initial release supporting only these ThinkSystem adapters:
         Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter (7ZT7A00484) 
         Broadcom NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter (7ZT7A00482)

===============================================================================
===============================================================================

Firmware Version: 17.4.4.8-c
----------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.47
      5720          1.39

    System x Adapters / LOMs
    ------------------------
    UEFI Code       17.4.9
    PXE Code        17.2.1 
    ISCSI Code      18.0.0 
    IMFW Code       1.12   
    NCSI Code       1.04.01


    Problems Fixed:
       
      - Corrected an issue where the Permanent MAC Address reported via IMM may
        be incorrect or duplicated
      - Bogus "SMASH" entry may appear in F1 setup firmware menu after LOM 
        update.

    Enhancements:   

===============================================================================
===============================================================================

Firmware Version: 17.4.4.7a
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.47
      5720          1.39
       
    System x Adapters / LOMs
    ------------------------
    UEFI Code       17.4.8
    PXE Code        17.2.1 
    ISCSI Code      18.0.0 
    IMFW Code       1.12   
    NCSI Code       1.04.01


   Problems Fixed:

      -  Fixed issue with tx/rx flow control in shared nic mode where connection
         to IMM is lost for a period of time after the server is powered off.
      -  Fixed issue with mac address filtering in shared nic mode where 
         connection to IMM is lost after a system reboot.

       
   Enhancements:   

      -  Added individual port enable/disable functionality in F1 Setup and 
         ASU/OneCLI for the following:
         Adapters:       NetXtreme I Quad Port GbE Adapter 
         Systems (LOMs): x3650 M5, x3550 M5, x3500 M5 

===============================================================================
===============================================================================

Firmware Version: 17.4.4.2a
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.43
      5720          1.39
       
    System x Adapters / LOMs
    ------------------------
    UEFI Code       17.4.0      
    PXE Code        17.2.1 
    ISCSI Code      18.0.0 
    IMFW Code       1.12   
    NCSI Code       1.03.12


    Problems Fixed:

      - Updated the firmware update tool, a bug was found where it would not 
        attempt to update package version 15.x.x code.
       
    Enhancements:   

===============================================================================
===============================================================================

Firmware Version: 17.4.3.3a
---------------------------

    Boot Code
      ASIC          Version
      ----          -------
      5717          1.65
      5717_C0       2.10
      5718          1.65
      5719          1.43
      5720          1.39

    System x Adapters / LOMs
    ------------------------
    UEFI Code       17.4.0      
    PXE Code        17.2.1 
    ISCSI Code      18.0.0 
    IMFW Code       1.12   
    NCSI Code       1.03.12
       
    Problems Fixed:
      -  ASU or XClarity is not able to restore default ISCSi settings 
         (such as 0.0.0.0) for adapters 90Y9352 and 90Y9370
      -  Invalid ISCSI parameters detected with ASU or XClarity on adapter 
         49Y7900.
      -  Flex x220 does not provide correct UUID to BOFM.
      -  Updated permanent MAC address retrieval logic when reporting the 
         value to AIM.
      -  Update permanent MAC address retrieval logic when reporting value to 
         additional AIM fields.
      -  Updated driver to modify attribute pattern strings for OEM devices. 
      -  Removed extraneous HII page which was causing OEM parameter 
         extraction utility to show improper configuration.
      -  Update permanent MAC address retrieval logic when reporting value to 
         AIM.
       
    Enhancements:   





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

Broadcom NX-1 Ethernet Device Driver for RHEL6



===============================================================================
                     Broadcom Netxtreme Device Driver for Linux
===============================================================================

Device Driver Version: 3.137x

Problems Fixed:
 - tg3: Fix compilation error on kernel >= 4.13
 

Incremental Interoperability:
 - None

Known Issues:
 - None

===============================================================================





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved