Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SR950 (7X12, 7X11, 7X13)
Targeted Operating System: RHEL7.5
YUM Repository Build Date: 2019_04_23

YUM Repository Release Version: 19A

Device:
ThinkSystem 430-8e SAS/SATA 12Gb HBA

Device Product Guide

Part Number: 7Y37A01090
Feature Code: AUNM
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0202


Release History:
Release: 19A
Change History Documents
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-08.01.05.00-1
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-3.03-06
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-27.125.01.00_el7.5- 1.x86_64.rpm 27.125.01.00_el7.5
Utilities Utility Name Version
LSI Storage Authority Software for windows and linux 004.189.000.000
StorCLI command line tool for anyos storcli-007.0713.0000.0000

Release: 18D
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA(06.02.00.01) 430-06.02.00.01
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-25.125.02.00_el7.5- 1.x86_64.rpm 25.125.02.00_el7.5

Release: 18B
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-06.01.00.07
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-25.125.01.00_el7.5- 2.x86_64.rpm 25.125.01.00_el7.5


Release 19A Change History Documents

BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA



ThinkSystem 430-x SAS/SATA 12Gb HBA Firmware and BIOS Update

Supported Adapters:  
             ThinkSystem 430-8i SAS/SATA 12Gb HBA        
		     ThinkSystem 430-16i SAS/SATA 12Gb HBA        
			 ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA    
		     ThinkSystem 430-8e SAS/SATA 12Gb HBA          
		     ThinkSystem 430-16e SAS/SATA 12Gb HBA        

NOTE TO SERVICE - Reference RETAIN #N/A

Version  08.01.05.00-1
---------------
    BIOS            Firmware      UEFI Driver      
  9.15.00.00        08.00.03.00    8.00.00.00     

IT Phase 8 (new)
 
Defects:
 - Marlin RMC: Fix checking of cores in reset during ChipReset sequence.(SCGCQ01197528) 
 - ((SATA Only) Security Protocol In command complete without data transfer for allocation length not a multiple of 512.(SCGCQ01275335) 
 - Charlotte DVT (3616) - Fails PCI Express Compliance Configuration Test.(SCGCQ01320438) 
 - Ventura: MCTP PCIe VDM: Discovered flag is set in Endpoint Discovery command.(SCGCQ01486410) 
 - The soft FIFO size calculations don't take into account the data descriptor sf threshold.(SCGCQ01488633) 
 - Controller is not detecting in the storelib, after changing the mode from "set mode oob" command.(SCGCQ01494018) 
 - PL: Update internal macros.(SCGCQ01503214) 
 - Ventura build failure.(SCGCQ01505238) 
 - RMC: Prevent leakage of P credits during SoftReset(SCGCQ01507699) 
 - Fixed IOP coverity defect for intruder.(SCGCQ01508917) 
 - PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB.(SCGCQ01509770) 
 - Fault 0xC00C is occurred in random read running test.(SCGCQ01511237) 
 - pl: backend PCIe: 4311 fault with NVMe enabled.(SCGCQ01514521) 
 - Ventura hardware does not like the IOP enable method used here.(SCGCQ01514880) 
 - (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices.(SCGCQ01516277) 
 - pl: backend PCIe: non-NVMe endpoint not cleaned up on removal.(SCGCQ01516968) 
 - Fault(0x4330) is occurred during checking MPI2_IOCSTATUS_TARGET_TOO_MUCH_WRITE_DATA.(SCGCQ01518952) 
 - Fixing the issues during bringup of the universal backplane.(SCGCQ01522148) 
 - pl: backend PCIe: switch attached discovery takes too long.(SCGCQ01522343) 
 - pl: backend PCIe: 4311 fault with NVMe enabled (part 2).(SCGCQ01523531) 
 - Ventura: Add early notification to new I2C-DMA-Less algorithm in case hardware doesn't interrupt.(SCGCQ01524953) 
 - pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset.(SCGCQ01526236) 
 - Handling of host PCI BAR programming changes after port enable.(SCGCQ01530295) 
 - pl: NVMe: EC0D fault.(SCGCQ01530402) 
 - PL Fault 0000ecdd LR 01403837 during initial discovery.(SCGCQ01531770) 
 - To fix issues for back plane configuration validation and LED control for the UBM backplane.(SCGCQ01533852) 
 - Ventura: Some toplevel PCE interrupts have a priority that is too low.(SCGCQ01534773) 
 - pl: backend PCIe: 4311 fault (part 3).(SCGCQ01537791) 
 - pl: NVMe: unexpected task management halt when a device goes missing.(SCGCQ01538012) 
 - Fault 5850 occurred in random read test with Task management.(SCGCQ01538680) 
 - pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment.(SCGCQ01540226) 
 - Ventura B0: FW blocking SATA devices behind enclosures.(SCGCQ01552996) 
 - (SATA Only) Incorrect sense data may be returned when a NCQ Queued Error Log data page is returned.(SCGCQ01553853) 
 - pl: backend PCIe: tweaks to the backend PCIe link configurations API.(SCGCQ01556422) 
 - IT/PL FW Compliance to use of NO FLUSH bit in START STOP UNIT based on SAT3.(SCGCQ01563244) 
 - pl: verify that RAID context Timeout value is nonzero before adding a timer.(SCGCQ01564757) 
 - pl: NVMe: admin command Abort Task reset type.(SCGCQ01565972) 
 - pl: backend PCIe: 'pl pci swregs' debug command is broken.(SCGCQ01566859) 
 - Ventura B0 Phase 7 - Fault 2805 hit after enabling auto port feature.(SCGCQ01572362) 
 - To fix the LED issue, VPP data and moving to change detect poll state.(SCGCQ01576165) 
 - (SATA Only.(SCGCQ01577907) 
 - pl: vSES - Enable Swap bit support in SES page 2.(SCGCQ01590780) 
 - Ventura B0: Windows server 2016 OS may not detect all drives on OEM backplane in a mixed mode config(SCGCQ01592762) 
 - Several firmware build utilities don't compile anymore.(SCGCQ01594270) 
 - Observed Exception during Test run: IocStatus: Insufficient Resources (0006).(SCGCQ01600177) 
 - Device block and unblock messages observed for the existing connected NVMe drives when new NVMe drive is inserted.(SCGCQ01615532) 
 - Firmware Build Utilities: AddImage utility gets flagged and removed by anti-virus software.(SCGCQ01619096) 
 - Ventura: Build time duration started displaying negative time.(SCGCQ01630393) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01639482) 
 - Missing code to handle no response in MCTP transmit buffer and send busy retry(SCGCQ01676010) 
 - Aero RMC: Fix non-secure boot mode(SCGCQ01683135) 
 - pl: NVMe: unnecessary SATA cleanup attempted during NVMe TM.(SCGCQ01683245) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01684262) 
 - Mercator: AHR failure when using workaround for SCGCQ01318807(SCGCQ01685001) 
 - SGPIO SCLK Glitch and Low upon coming out of reset(SCGCQ01697481) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted (part 2).(SCGCQ01727593) 
 - pl: backend PCIe: notification events for switches with no devices attached(SCGCQ01729831) 
 - Ventura: CFGI fails if the largest MPI defined config page is not included(SCGCQ01737603) 
 - Aero build fails.(SCGCQ01748072) 
 - pl: NVMe: unexpected switch attached task management timeouts(SCGCQ01763332) 
 - Ventura B0: 0x5842 fault while running IOs and error injection tests(SCGCQ01780777) 
 - (SATA Only)Sense descriptor not filled properly for SCSI ATA Passthrough command failed by drive with SDA bit set.(SCGCQ01784132) 
 - Ventura B0: Controller fault 0x7C41 observed during IO+System power cycle test(SCGCQ01790305) 
 - pl: NVMe: ECF0 fault(SCGCQ01790929) 
 - PL SATL: SANITIZE Command failing for SATA SMR drives with ZNR bit set(SCGCQ01800567) 
 - pl: NVMe: SCSI log page temperature may be incorrect in some cases(SCGCQ01804437) 
 - pl: NVMe: Reference Temperature in the Temperature log page is incorrect(SCGCQ01807465) 
 - pl: backend PCIe: debug info for port enable subsystem integration(SCGCQ01817645) 
 - Incorrect Element status reported in SES Page 2 by vSES when connected to an expander(SCGCQ01822333) 
 - PL needs to check if we have a path to the end device before issuing a device reset to an NVMe drive as a part of TM(SCGCQ01826234) 
 - pl: NVMe: TransferCount in the SCSI IO error reply message may be invalid(SCGCQ01830303) 
 - pl: NVMe: unexpected read/write IO failure with SkipCount error(SCGCQ01835109) 
 - Fix to CSET SCGCQ01605489(SCGCQ01837880) 
 - Ventura PL: New HW Workaround for 0x670A Fault(SCGCQ01841683) 
 - RMC: Add full interrupt disable to SBR Reload code(SCGCQ01212765) 
 - SCSI format command send to NVMe drives fails with CMPLIST flag set in addition to FMTDATA flag(SCGCQ01229799) 
 - SPI reset delay needs to be enabled in B0 revs(SCGCQ01241767) 
 - pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01487423) 
 - pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01518343) 
 - To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01542497) 
 - PL: Implemented HW workaround to solve 6G SATA link fail problem(SCGCQ01554661) 
 - Ventura: If firmware download is done in small pieces, firmware download fails with logInfo 30010402(SCGCQ01558208) 
 - pl: backend PCIe: EC52 fault(SCGCQ01565749) 
 - Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01574224) 
 - Remove and Truncate command handler: IO was not failed with check condition(SCGCQ01594602) 
 - Aero-3: make aero doesn't compile(SCGCQ01614670) 
 -(SCGCQ01615484) 
 - Aero3: Signed CBB hangs(SCGCQ01624857) 
 - Aero DDR: DDR fails after issuing MSS reset(SCGCQ01685637) 
 - Ventura: OEM ID66 PCIe Switch backplane Slots Status Amber LEDs stay blinking(SCGCQ01687610) 
 - RMC: Need to use AHB path to write to Reset Status Register(SCGCQ01718319) 
 - Ventura: OEM PCIe dual switch attached backplane slot status LED stays Amber on partial slots(SCGCQ01788989) 
 - MCTP: 0x265D fault occurs when running high MCTP PCIe VDM load with MCTP Discovery commands(SCGCQ01790303) 
 - Update combo serdes library version.(SCGCQ01791178) 
 - Interrupts not handled in fault state if a high priority interrupt handler faults(SCGCQ01802508) 
 - Ventura PL: 0x670A Fault During Destructive Domain Testing(SCGCQ01831332) 
 - Ventura B0: Slot status updates to certain slot on NVMe backplane may not update the LED status(SCGCQ01573106) 
 - MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN	  (SCGCQ01631826) 
 - (SATA Only)When ATA command fails with sense data available bit set, Data frame may not be released.(SCGCQ01732835) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01742362) 
 - Fault C010 encountered when running IO to 9405W-16e in Target Mode(SCGCQ01368001) 
 - (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct.(SCGCQ01638248) 
 - Ventura: In mixed topology, attn LED is non-functional for SAS/SATA drives on OEM backplane(SCGCQ01930666) 
 - PDB data path parity error workaround(SCGCQ01733783) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01765873) 
 - Ventura: Locate operation to SAS/SATA drive slot may not turn on the status LED on OEM backplane(SCGCQ01789068) 
 - Negotiated Link Speed for the vSES target is displayed as 'Unknown'.(SCGCQ01606720) 
 - Not all NVMe drives were discovered after server cold or warm boot(SCGCQ01664963) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01671177) 
 - VPD is not shown by lspci(SCGCQ01687750) 
 - Not all NVMe drives discovered as part of hot plug operation(SCGCQ01697329)
- PL: Error LED stays on when drive is pulled out when using unusual slot mapping and drive presence check(SCGCQ01222315 port of SCGCQ01157331) 
 - 9305-16i - Activity LED signal is not asserted for port 2 and 3.(SCGCQ01382008 port of SCGCQ01318981) 
 -(SCGCQ01431063 port of SCGCQ01415060) 
 - SATA ONLY: VPD page 0xB2 LBPU bit not set correctly.(SCGCQ01511589 port of SCGCQ01374552 port of ) 
 - IOP: Differentiate between L2 correctable and uncorrectable faults(SCGCQ01512630 port of SCGCQ00929810) 
 - IOP: Faulting for correctable L2 parity errors(SCGCQ01512800 port of SCGCQ00934325) 
 - PL: SAS3 PHASE12 RAID creation failing with SATA drives.(SCGCQ01512834 port of SCGCQ00998155) 
 - Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01513298 port of SCGCQ00856085) 
 - Fault State Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01514262 port of SCGCQ00856085) 
 - IOP: Faulting for L2 Cache Correctable Errors(SCGCQ01514707 port of SCGCQ01264714) 
 - (SATA Only)Signature FIS not validated for Expander attached SATA drives(SCGCQ01514869 port of SCGCQ00852290) 
 - STANDBY_Z Bit Not Set in POWER CONDITION MODE PAGE When Mode Sense (10) is executed to NON EPC SATA Drive(SCGCQ01518957 port of SCGCQ00845242) 
 - Need to expose pure SEP devices through the inventory command(SCGCQ01519056 port of SCGCQ00943216) 
 - pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01519802 port of SCGCQ01518343) 
 - pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01522511 port of SCGCQ01487423) 
 - pl: backend PCIe: 4311 fault with NVMe enabled (part 2)(SCGCQ01523550 port of SCGCQ01523531) 
 - Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01525228 port of SCGCQ01450475) 
 - pl: backend PCIe: non-NVMe endpoint not cleaned up on removal(SCGCQ01529383 port of SCGCQ01516968) 
 - PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB(SCGCQ01529512 port of SCGCQ01509770) 
 - PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01533308 port of SCGCQ01505468) 
 - PL Fault 0000ecdd LR 01403837 during initial discovery(SCGCQ01539840 port of SCGCQ01531770) 
 - Increase the default SES buffer size to 2K(SCGCQ01540666 port of SCGCQ01506013) 
 - PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01556419 port of SCGCQ01520524) 
 - pl: backend PCIe: switch attached discovery takes too long(SCGCQ01556426 port of SCGCQ01522343) 
 - Collect enclosure Bay ID from OEM specificinternal backplanes(SCGCQ01562101 port of SCGCQ01503517) 
 - pl: NVMe: device may not appear in OS following NVMe init failure(SCGCQ01594709 port of SCGCQ01593528) 
 - pl: NVMe: Write Long (10)(SCGCQ01595859 port of SCGCQ01593652) 
 - DDRlib failures occur if debug prints are disabled.(SCGCQ01599770 port of SCGCQ01482222) 
 - pl: NVMe: D102 fault(SCGCQ01608155 port of SCGCQ01605590) 
 - (SATA Only)SCSI Unmap command to some SATA drives are timing out.(SCGCQ01615122 port of SCGCQ01539572) 
 - (SATA Only)ATA Request Sense Ext command sometimes not send when the drive responds with 'Sense Data Available' bit set.(SCGCQ01615159 port of SCGCQ01571933) 
 - (SATA Only)Only) ATA Request Sense Ext command not sent for failed SCSI Unmap command sent to a SATA drive.(SCGCQ01615209 port of SCGCQ01593844) 
 - (SATA Only)Only) Incorrect data sent in response of SCSI Inquiry command for some SATA drives.(SCGCQ01616465 port of SCGCQ01599707) 
 - Increase the default SES buffer size to 2K.(SCGCQ01616503 port of SCGCQ01506013) 
 - (SATA Only)Only) Timer for SCSI Write Verify command to a SATA drive might get removed before command completion.(SCGCQ01616558 port of SCGCQ01593136) 
 - (SATA Only)Only) ATA Request Sense Ext command being sent after ATA command translated for SCSI Start Stop Unit command fails with Sense Data Available.(SCGCQ01618209 port of SCGCQ01599542) 
 - Task Management due to SATA init failure results in resource error message(SCGCQ01618661 port of SCGCQ01605610) 
 - pl: backend PCIe: EC59 fault(SCGCQ01618750 port of SCGCQ01615981) 
 - PL Enclosure Management: SEP Blink Request Fails After Path 1 Disconnect in Multipath Topology(SCGCQ01619021 port of SCGCQ01618625) 
 - pl: NVMe: 61A6 fault.(SCGCQ01619934 port of SCGCQ01602703) 
 - (SATA Only)SCSI Unmap command to some SATA drives are timing out.(SCGCQ01621120 port of SCGCQ01539572) 
 - Not all NVMe drives are discovered on VPP backplane Enclosure.(SCGCQ01623525 port of SCGCQ01620856) 
 - IO starvation and performance degradation when using dma Q masking feature.(SCGCQ01627326 port of SCGCQ01505074) 
 - When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01628174 port of SCGCQ01601413) 
 - The change detect feature macro missing, leading to compilation issue(SCGCQ01628450 port of SCGCQ01616460) 
 - The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628453 port of SCGCQ01623437) 
 - (SATA Only) Incorrect Sense Key and Additional Sense Code set for failed Start Stop Unit command.(SCGCQ01630267 port of SCGCQ01628346) 
 - Ventura: No easy way to tell if config pages have been written(SCGCQ01630398 port of SCGCQ01630331) 
 - Ventura B0: 5813 fault while running destructive domain test(SCGCQ01630895 port of SCGCQ01623624) 
 - Negotiated Link Speed for the vSES target is displayed as 'Unknown'.(SCGCQ01639536 port of SCGCQ01606720) 
 - SES Page 2 does not show the correct status information for Direct Attached NVMe drives(SCGCQ01639840 port of SCGCQ01620857) 
 - Blank Boards with Auto Port Enable set in NVDATA will fault(SCGCQ01639859 port of SCGCQ01553238) 
 - SES Page 2 Overall Status-Status Info bits do not reflect the correct status after fault conditions are cleared(SCGCQ01639873 port of SCGCQ01620243) 
 - Align vSES diag page response with Expander SEP diag page response(SCGCQ01639886 port of SCGCQ01585387) 
 - MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN(SCGCQ01675747 port of SCGCQ01631826) 
 - Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676883 port of SCGCQ01670180) 
 - Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01682349 port of SCGCQ01670965) 
 - pl: NVMe: E411 fault(SCGCQ01686689 port of SCGCQ01684788) 
 - IO unit control IOC_CTRL_OP_ALL_PHY_LOOPBACK_DIAG hangs on 8 phy controller(SCGCQ01687624 port of SCGCQ01623477) 
 - Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01687743 port of SCGCQ01619417) 
 - Mercator Phase7: VMWare PSODs due to NMI error when the Windows VM that has passthrough controller is being shutdown(SCGCQ01697675 port of SCGCQ01617769) 
 - VPD is not shown by lspci(SCGCQ01698316 port of SCGCQ01687750) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01713180 port of SCGCQ01681441) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01714249 port of SCGCQ01681441) 
 - Unhandled exception results in a fault(SCGCQ01721368 port of SCGCQ01686666) 
 - (SATA Only) When ATA command fails with sense data available bit set, Data frame may not be released.(SCGCQ01745744 port of SCGCQ01732835) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01760767 port of SCGCQ01742362) 
 - Host memory corruption seen during Progress polling of Sanitize operation on SATA drives(SCGCQ01762343 port of SCGCQ01721050) 
 - IO not completing or being timed out if some cases when an unconfirmed response is received for an IO.(SCGCQ01767091 port of SCGCQ01718897) 
 - PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request(SCGCQ01788903 port of SCGCQ01614814) 
 - IOC_CTRL_OP_ALL_PHY_LOOPBACK operation is not working(SCGCQ01792619 port of SCGCQ01670396) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted(SCGCQ01794153 port of SCGCQ01760627) 
 - [Ventura][PL] Applications trying to update NVMe device Firmware with Mode E fails.(SCGCQ01849388 port of SCGCQ01624790) 
 - Ventura PL: Check in Revised Workaround for 0x5842 fault - Rx Dma Memory Overflow(SCGCQ01896576 port of SCGCQ01864843) 
 - Add workaround for SATA drive not complaint with ACS-3(SCGCQ01935094 port of SCGCQ01922154) 
 - (NVME)Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.(SCGCQ01944370 port of SCGCQ01932728) 
 - Source code uses tlbInitHDCW and HDCW instead of HCDW(SCGCQ01118580 port of SCGCQ01089693) 
 - PL: SSD drop by SAS3008 during the hotplug test.(SCGCQ01516685 port of SCGCQ00897639) 
 - Coverity defects : The function seem called twice and identical code in different branches.(SCGCQ01516906 port of SCGCQ00939071) 
 - Ventura hardware does not like the IOP enable method used here.(SCGCQ01519729 port of SCGCQ01514880) 
 - (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices(SCGCQ01524353 port of SCGCQ01516277) 
 - Controller is not detecting in the storelib, after changing the mode from "set mode oob" command(SCGCQ01530310 port of SCGCQ01494018) 
 - pl: NVMe: EC0D fault.(SCGCQ01533267 port of SCGCQ01530402) 
 - Storlib observed ERROR_MCTP_PAYLOADID_PE_INVALID_PARAM while doing attn-btn test(SCGCQ01542429 port of SCGCQ01423338) 
 - covery defects on Intruder 19849 & 19842(SCGCQ01542431 port of SCGCQ01484250) 
 - pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment(SCGCQ01556893 port of SCGCQ01540226) 
 - Performance Improvements(SCGCQ01562099 port of SCGCQ01455538) 
 - pl: NVMe: modify Bus Master Enable usage during NVMe controller reset(SCGCQ01587095 port of SCGCQ01581273) 
 - pl: backend PCIe: generic message header dWords 2 and 3 are swapped(SCGCQ01599051 port of SCGCQ01598812) 
 - Ventura B0 Phase 7 - Fault E404 during IOTM testing with 24 NVMe drives and 3 switches(SCGCQ01600602 port of SCGCQ01570622) 
 - Requested capacity field translations are incorrect for remove element & truncate command(SCGCQ01614097 port of SCGCQ01510418) 
 - (SATA Only) ATA Request Sense Data Ext command not send to device when it fails translated SCSi Security Protocol Out.(SCGCQ01618558 port of SCGCQ01605100) 
 - Ventura: FW Signing Support failing with loginfo during FWDL(SCGCQ01618988 port of SCGCQ01605427) 
 - pl: NVMe: hot-added device may not appear in OS during heavy IO load(SCGCQ01619018 port of SCGCQ01616267) 
 - Ventura: Duplicate slot numbers assigned for drives in certain mixed mode cabling configurations(SCGCQ01623485 port of SCGCQ01606122) 
 - pl: NVMe: ECEC fault(SCGCQ01623903 port of SCGCQ01620613) 
 - To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01628440 port of SCGCQ01507506) 
 - Change detect feature support on UBM supported back plane(SCGCQ01628444 port of SCGCQ01605371) 
 - The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628452 port of SCGCQ01623437) 
 - (SATA Only) SCSI Log Select command not failed with check condition when translated ATA command is failed by SATA drive.(SCGCQ01633320 port of SCGCQ01631836) 
 - PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01639906 port of SCGCQ01505468) 
 - PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01646094 port of SCGCQ01572062) 
 - Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01681401 port of SCGCQ01670965) 
 - Not all NVMe drives were discovered after server cold or warm boot(SCGCQ01732107 port of SCGCQ01664963) 
 - Not all NVMe drives discovered as part of hot plug operation(SCGCQ01732136 port of SCGCQ01697329) 
 - The x4 link configuration was not detected by UBM module(SCGCQ01735502 port of SCGCQ01735485) 
 - PL: Avoid Duplicate Mid Workaround Does Not Start a TM If Device is Removed and Re-Added(SCGCQ01748033 port of SCGCQ01715677) 
 - PL support for monitoring the progress of sanitize operation.(SCGCQ01753174 port of SCGCQ01591935) 
 - When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01761718 port of SCGCQ01601413) 
 - Data NAK of large master TX packet can stop I2C out of band(SCGCQ01766431 port of SCGCQ01713685) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01798286 port of SCGCQ01792208) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01851004 port of SCGCQ01765873) 
 - Ventura: Attaching multiple PCIe switches may cause IOP memory corruption(SCGCQ01875221 port of SCGCQ01853893) 
 - pl: backend PCIe: 4311 fault with NVMe enabled(SCGCQ01520574 port of SCGCQ01514521) 
 - (SATA Only)Security Protocol In command complete without data transfer for allocation length not a multiple of 512(SCGCQ01524638 port of SCGCQ01275335) 
 - pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset(SCGCQ01527219 port of SCGCQ01526236) 
 - IOP: FW to clear all pending PCI interrupts during a Function Level Reset (FLR(SCGCQ01534881 port of SCGCQ01523541) 
 - pl: backend PCIe: potential address range overlap(SCGCQ01592870 port of SCGCQ01586393) 
 - Fixing the issues during bringup of the universal backplane.(SCGCQ01599610 port of SCGCQ01522148) 
 - Race condition can allow IOs over OOB to removed drive, with no host IOs, to not be cleaned up, and possibly leading to new drives not showing up(SCGCQ01605489 port of SCGCQ01400110) 
 - (SATA Only) Incorrect Additional sense code when SCSI Format to a SATA drive fails(SCGCQ01615216 port of SCGCQ01598756) 
 - (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct.(SCGCQ01668674 port of SCGCQ01638248) 
 - Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01698231 port of SCGCQ01619417) 
 - PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715880 port of SCGCQ01715509) 
 - PL support for monitoring sanitize operation after controller/device reset.(SCGCQ01753176 port of SCGCQ01591995) 
 - [ventura] PL Fault 0000ecc9 observed, while running doing drive Pull-Push with IO's in background(SCGCQ01817256 port of SCGCQ01804290) 
 - Ventura MSS: Multi-bit ECC, EFI SAS DRIVER issue seen when performed multi reboot stress from UEFI(SCGCQ01822452 port of SCGCQ01794025) 
 - Heavy IO with low IO timeout test may result into an IO getting missed.(SCGCQ01840466 port of SCGCQ01631346) 
 - Fault 4311 when running repeated controller resets(SCGCQ01872930 port of SCGCQ01865882) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893313 port of SCGCQ01671177) 
 - Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01530305 port of SCGCQ01450475) 
 - pl: NVMe: unexpected target reset task management timeout(SCGCQ01587064 port of SCGCQ01580026) 
 - PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01615056 port of SCGCQ01572062) 
 - PL: (SATA Only)SSU Command for active power condition transition on EPC enabled drive fails with Additional sense Logical block address out of range(SCGCQ01640974 port of SCGCQ01640762) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01714280 port of SCGCQ01681441) 
 -(SCGCQ01748041 port of SCGCQ01615484) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01817002 port of SCGCQ01792208) 
 - (SATA Only) SCSI Start Stop Unit command with power condition set to standby may fail for SATA drives.(SCGCQ01839608 port of SCGCQ01833392) 
 - To fix issues for back plane configuration validation and LED control for the UBM backplane.(SCGCQ01599611 port of SCGCQ01533852) 
 - IO starvation and performance degradation when using dma Q masking feature(SCGCQ01630921 port of SCGCQ01505074) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01684232 port of SCGCQ01639482) 
 - PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715875 port of SCGCQ01715509) 
 - PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01749480 port of SCGCQ01520524) 
 - Avoid releasing I2C bus when I2C operation(Read/Write) in progress.(SCGCQ01752794 port of SCGCQ01721931) 
 - To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01599612 port of SCGCQ01542497) 
 - Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01599616 port of SCGCQ01574224) 
 - MCTP: Fault 0x265D when packet with StartOfMsg is set and PktSeqCount is 1(SCGCQ01966436 port of SCGCQ01850721) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01967409 port of SCGCQ01942781) 
 - To fix the LED issue, VPP data and moving to change detect poll state(SCGCQ01599614 port of SCGCQ01576165) 
 - Change detect feature support on UBM supported back plane(SCGCQ01628442 port of SCGCQ01605371) 
 - Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676884 port of SCGCQ01670180) 
 - pl: NVMe: 61A6 fault(SCGCQ01763390 port of SCGCQ01602703) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906461 port of SCGCQ01906013) 
 - (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.(SCGCQ01961501 port of SCGCQ01955094) 
 - pl: backend PCIe: 4311 fault (part 3)(SCGCQ01574923 port of SCGCQ01537791) 
 - The x4 link configuration was not detected by UBM module(SCGCQ01747034 port of SCGCQ01735485) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01967384 port of SCGCQ01932394)
   
	
EnhancementRequests:
 - SATA SMR Only : Change for the FORMAT UNIT translation for SMR drives to also call RESET WRITE POINTER with ALL bit set(SCGCQ01218300) 
 - Add PLI Control Request to Fully Pause/Unpause FPE HW(SCGCQ01378809) 
 - Aero-3: CR#06: SPILib: Add necessary SPI timings to Aero/Sea to support multiple SPI Vendors(SCGCQ01380051) 
 - Aero-3: Update Clock, Configuration, and Reset (CCR) code.(SCGCQ01380109) 
 - Incorporate new PHY register initialization settings.(SCGCQ01405307) 
 - Aero DDR: PHY based Read Leveling(SCGCQ01405427) 
 - Aero DDR: PHY based Write Leveling(SCGCQ01405430) 
 - Aero: Internal Boot ROM Support(SCGCQ01410019) 
 - pl: backend PCIe: add API for getting backend PCIe link configurations(SCGCQ01437182) 
 - Re-enable flash initialization in bootloader.(SCGCQ01448314) 
 - (SATA Only) Add support for FIS Port (NCQ Encapsulation) of SCSI Write Same command.(SCGCQ01452113) 
 - MegaRaid VT BootLoader Flash Map Update For Ventura(SCGCQ01467197) 
 - Aero-3: Create framework for M0 processors(SCGCQ01499419) 
 - SAS3.5 (SATA Only): SATL need to send ATA REQUEST SENSE DATA EXT command when ATA device returns error and sense data available bit is on(SCGCQ01503732) 
 - Rebase Aero3 Development Stream and Verify Ventura Functionality(SCGCQ01509806) 
 - Ventura: Add MCTP over I2C Master Mode Option that doesn't use I2C DMA(SCGCQ01516871) 
 - Enable Backplane Management based on backplane type signal per HBA connector quad(SCGCQ01524982) 
 - pl: NVMe: add NVMe task management test code(SCGCQ01526049) 
 - Ventura: Specify leading zeros for the prints using %x in pl diag module(SCGCQ01533485) 
 - Aero-3: Update RMC FW to follow the steps from Aero SOC uArch spec(SCGCQ01533491) 
 - Add a new flag to IoFlags in pliStartScsiIo(SCGCQ01544740) 
 - Ventura: Ensure new I2C non_DMA code compiles with MCTP disabled(SCGCQ01548925) 
 - Remove ENET(Ethernet support Bit 26(SCGCQ01555034) 
 - Remove CSW library from AERO builds(SCGCQ01558186) 
 - Change the default behavior for I2C MCTP to non-DMA(SCGCQ01565737) 
 - Intruder: Modify NVDATA to enable DMA by default(SCGCQ01566619) 
 - Update build to calculate build duration(SCGCQ01572912) 
 - Ventura: Specify leading zeros for the prints using %x in plDebugStrings(SCGCQ01576200) 
 - pl: NVMe: add support for Security Protocol In/Out INC_512 flag(SCGCQ01582520) 
 - Disable mapping of some device side PCIe hardware into CPU's virtual address space(SCGCQ01582599) 
 - Aero-3: Modify CBB build so that it decreases the hardware reserved area (SBR(SCGCQ01595798) 
 - RMC must add PCE PLL/Core Initialization for Secure Mode(SCGCQ01608224) 
 - Aero-3: Review Aero Impala changes(SCGCQ01614623) 
 - Aero-3: Review Aero SAS core changes(SCGCQ01614628) 
 - Aero: backend PCIe: update config pages for 16GT/s(SCGCQ01614647) 
 - Flag added in AERO to avoid sending IO requests to IOA NVMe core that could potentially cause exceptions(SCGCQ01615545) 
 - Aero: enable backend PCIe support in the Aero build(SCGCQ01619936) 
 - pl: backend PCIe: basic PCI hot plug power controller support for switches(SCGCQ01633888) 
 - Aero DDR: DDR library initialization on the FPGA(SCGCQ01634738) 
 - pl: NVMe: remove vendor specific prototype code(SCGCQ01638257) 
 - pl: NVMe: support for nonzero doorbell stride(SCGCQ01670300) 
 - SPI_LIBRARY: Aero/Ventura Provide Sufficient Information to Uniquely Detect Auto-Configured devices(SCGCQ01679097) 
 - Improve build times(SCGCQ01715410) 
 - Fine Tune iMR RAID IO path performance(SCGCQ01715637) 
 - Add debug print for unrecognized initial FIS(SCGCQ01718317) 
 - Aero: Move RSA defines in mpi_temp.h to a common area(SCGCQ01727399) 
 - ComboSerdes: add APIs for firmware coordination with the protocol cycler(SCGCQ01761386) 
 - Convert Aero build to Aero3(SCGCQ01349949) 
 - Aero Fpga support(SCGCQ01367141) 
 - Aero-3: Update ARM CPU Speed to 1600 MHz(SCGCQ01392205) 
 - Aero: Add 300MHZ UART Clock Reference Support(SCGCQ01392831) 
 - Aero3: Add secure boot specified header and add support in rom utilities for it(SCGCQ01399079) 
 -(SCGCQ01418823) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473898) 
 - PL: Create defines for plRequestFWBreak() Location Parameter(SCGCQ01499053) 
 - Aero-3: Ensure modifed SBR template data is compatible with Ventura(SCGCQ01509915) 
 - Support for NVDATA control of static slot number assignments for x2 or x4 NVMe devices(SCGCQ01511787) 
 - Ventura: Use non-DMA option for MCTP over I2C - Slave Mode(SCGCQ01516865) 
 - Ventura: Add symbol names to "iop show gic"(SCGCQ01519283) 
 - PCIe Switch attached NVMe Backplane LED Management support(SCGCQ01532296) 
 - Add Margay expander recognition to Ventura(SCGCQ01570647) 
 - Allow filtering of NVMe exception prints in debug mask(SCGCQ01575138) 
 - pl: NVMe: more NVMe TM test code(SCGCQ01605900) 
 - pl: backend PCIe: merge extended capability search functions(SCGCQ01613997) 
 - PL SATL: ZNR bit translation during SCSI SANITIZE command for SMR drive(SCGCQ01615513) 
 - Delete strings that are not used in plDebugStrings(SCGCQ01620668) 
 - Aero: backend PCIe: basic Atlas host interface board bringup(SCGCQ01736527) 
 - Ventura/Marlin: Detect attempt to downgrade from auto-detected SPI parts to non-auto and fail(SCGCQ01449329) 
 - PL: Use Sense Data from SATA Log Page 10 when querying Log Page 10(SCGCQ01459375) 
 - Aero: backend PCIe: modify outbound address window configuration(SCGCQ01485166) 
 - Ventura: Modify DMAless-I2C MCTP code so that that it processes most data in interrupts(SCGCQ01533036) 
 - Update tcc to version 0.9.27(SCGCQ01593619) 
 - PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request(SCGCQ01614814) 
 - Ventura/Aero: (Child) Implement Extended Mfg Page 45 - Aladin Config Page - Add config page(SCGCQ01680542) 
 - To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01507506) 
 - Aero-3: Modify the Aero3 build so that the main firmware image has a MPI Component Header(SCGCQ01509807) 
 - Aero-3: Disable MCTP over PCIe VDM Workarounds(SCGCQ01533532) 
 - Ventura: Detect various user errors in firmware download(SCGCQ01534545) 
	
 

Version  06.02.00.02
---------------
Contains:
    BIOS            Firmware      UEFI Driver
  9.11.00.00        06.00.16.00   06.04.02.00
  
Fixed: Bug 142622 - [Libra] One of the SAS port from Lenovo 430-16e failed to log back to the controller during controller reset

Defects (4)
- pl: NVMe: ED8D fault related improvements.(SCGCQ01789903)
- PDB data path parity error workaround.(SCGCQ01733783)
- To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues.(SCGCQ01765873)
- Ventura: Locate operation to SAS/SATA drive slot may not turn on the status LED on OEM backplane.(SCGCQ01789068)
- PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request.(SCGCQ01788903 port of SCGCQ01614814)
- When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01761718 port of SCGCQ01601413)
- [Ventura][PL] TM Hangs when doing drive push pull test case.(SCGCQ01798286 port of SCGCQ01792208)
- pl: NVMe: 61A6 fault.(SCGCQ01763390 port of SCGCQ01602703)

EnhancementRequests (1)
- Permit multiple calls to avSerdesSASSDAddTxEqSeq and implement aviSerdesSASSDWaitIntrSmIdle for SAS35XFW.(SCGCQ01720492)

Version 06.01.00.07
---------------
Contains:
    BIOS            Firmware      UEFI Driver
  9.11.00.00        06.00.12.00   6.04.00.00

Defects (96)
- SAS Power Management and PCal do not work together.(SCGCQ01201827)
- pl: backend PCIe: ECE4 fault.(SCGCQ01312345)
- Ventura SBR: Changes to PLL reset requirements cause lock failure on some boards.(SCGCQ01373888)
- IOP: Improvements to AXI HWWA.(SCGCQ01390095)
- Ventura B0: Missing signing supported firmware image in RO.(SCGCQ01392675)
- PCI SIG Compliance Test Failure - Test 1_41 Link Capabilities 2, Link Control 2, Link Status 2 Failures.(SCGCQ01394478)
- Customer specific SAS 12g drive frequently links up at 6g..(SCGCQ01397553)
- pl: NVMe: async event persistent conditions monitor issues.(SCGCQ01414966)
- Internal Task Management operations not completing in out of resource conditions.(SCGCQ01415544)
- 0x6004 Fault during TM injection while running IO to Sata SSDs..(SCGCQ01416481)
- Add SAS device discovery error event to IOP message events..(SCGCQ01428178)
- Ventura: Misc tri-mode backplane mgmt detection fixes and Slot status update changes.(SCGCQ01428718)
- pl: NVMe: memory leak in Verify (10/12/16) command translation.(SCGCQ01429659)
- pl: Mode Select translation transfer length validation.(SCGCQ01435884)
- File name capitalization doesn't match #include and fails when building with Linux.(SCGCQ01439249)
- SGPIO Clock driven Low on host PCIe reset assertion causing SGPIO target to latch on invalid data.(SCGCQ01440481)
- Ventura B0: Fault 0x510B while doing reboot test along with IOs & TMs.(SCGCQ01440764)
- Ventura: NVMe Target: REPORT LUNS SCSI Command Failed With CC for Supported SELECT REPORT field Values 01h, 10h or 12h.(SCGCQ01444725)
- Ventura: NVMe Target: When MODE SENSE Command Executed for all supported Modes Pages, TRACK SKEW FACTOR Set as 0x01.(SCGCQ01444843)
- A previous code change is missing a few changes..(SCGCQ01449239)
- PL trying to perform memory move using address which is in the non-addressable range.(SCGCQ01450399)
- pl: NVMe: EC26 fault.(SCGCQ01451332)
- vSES Target: Incorrect Sense Data for REQUEST SENSE Command.(SCGCQ01451678)
- pl: backend PCIe: erroneous address pool copy.(SCGCQ01455651)
- pl: port enable may fail to complete if an OEM backplane is attached.(SCGCQ01455680)
- Ventura: Break up backplane mgmt device ISTWI Read/Write to the supported size.(SCGCQ01456349)
- Hot plugged NVMe drive fails to link up on OEM backplanes with ISTWI drive presence polling enabled.(SCGCQ01463496)
- Ventura: Firmware Update Algorithm Frees Mids Twice.(SCGCQ01465058)
- pl: NVMe: 6001 fault.(SCGCQ01468144)
- To support the I2C bus reserve state in the case of UBM backplane.(SCGCQ01470385)
- pl: NVMe: port enable may complete before devices link up.(SCGCQ01472531)
- Ventura VSES: Incorrect data in diagnostic page 0xA when drive is missing but not yet removed..(SCGCQ01472941)
- The "pl reg" command dumps the wrong amount of data for some structures..(SCGCQ01474266)
- PL: SATA: Sense Key/Additional Sense code incorrectly set when open zone issued on a Security locked SMR drive.(SCGCQ01478037)
- Ventura vSES: Direct attached NVME drives are not getting associated with vSES in Microsoft Storage Spaces Direct..(SCGCQ01478170)
- Drive addition in OS takes longer time when Drives are connected with certain backplanes to the controller.(SCGCQ01479406)
- SATL: Security Protocol Erase fails in SATL, but works well with ATA PT.(SCGCQ01479409)
- pl: NVMe: task management timeout may occur.(SCGCQ01480646)
- Ventura B0: Controller Reset causing OS hang and resets.(SCGCQ01480987)
- MPI SEP request to Slots with invalid SES Page 0A element index may not complete.(SCGCQ01482937)
- pl: NVMe: improved fix for 6001 fault.(SCGCQ01484382)
- pl: 265D fault on 'pl dbg' before port enable.(SCGCQ01485059)
- (SATA Only) Format of SATA SSD takes long time.(SCGCQ01485060)
- Ventura/Marlin: Firmware Download does not protect user from downgrading to firmware that does not support Winbond.(SCGCQ01485441)
- Host application hangs waiting for completion of IO issued after NVMe device is removed.(SCGCQ01486695)
- pl: NVMe: switch attached devices not detected under Windows.(SCGCQ01487291)
- SATA: Report Zone for very large data of 4MB takes ~2 seconds for processing.(SCGCQ01502700)
- Ventura FW may fault on single bit correctable ECC errors in IOA Local RAM.(SCGCQ01503262)
- pl: backend PCIe: additional phy hardware cleanup on link down and hot reset.(SCGCQ01504284)
- pl: backend PCIe: LTSSM state wait during hot reset.(SCGCQ01504310)
- SAS3.5FW_Common_Main was not stable after merging code changes for SCGCQ01421231.(SCGCQ01508018)
- (SATA Only) SCT Error Recovery Control read using ATA Passthrough is not returning correct values.(SCGCQ01509632)
- Ventura: 4311 fault with NVMe enabled.(SCGCQ01519732)
- pl: backend PCIe: 4311 fault with NVMe enabled (part 2).(SCGCQ01522342)
- pl: backend PCIe: 4311 fault (part 3).(SCGCQ01571588)
- Ventura B0: Windows server 2016 OS may not detect all drives on OEM backplane in a mixed mode config.(SCGCQ01592762)
- Device block and unblock messages observed for the existing connected NVMe drives when new NVMe drive is inserted.(SCGCQ01615532)
- pl: backend PCIe: ED8D fault.(SCGCQ01628411)
- SGPIO SCLK Glitch and Low upon coming out of reset.(SCGCQ01697481)
- pl: NVMe: ED8D fault.(SCGCQ01698373)
- pl: backend PCIe: E984, E9A4, EF50, EF52 faults.(SCGCQ01294948)
- Task Management request of Abort Task to an NVMe device completes with failure status if the target of the Abort is not a currently active IO from the controller's point of view.(SCGCQ01334586)
- pl: NVMe: missing AccessStatus codes.(SCGCQ01352937)
- Doorbell handshake hangs when faulted.(SCGCQ01384089)
- PCI SIG Compliance Test Failure - Test 1_8 Virtual Channel.(SCGCQ01394426)
- The Avoid Duplicate Mid feature does not activate properly for expander attached SATA devices.(SCGCQ01405083)
- When disabling one phy of a port the other phys of the same port do not relink after reset..(SCGCQ01418575)
- 9405W-16i xml not available in Latest Release Order.(SCGCQ01429439)
- GoldenX: When no BIOS option is selected the images are 1MB too small.(SCGCQ01448015)
- Ventura: NVMe : Log Sense Command Executed for Information Exceptions Log Page has TSD field set to 0b.(SCGCQ01448752)
- pl: backend PCIe: link may fail to come up after link break.(SCGCQ01451278)
- (VSES) SES INQUIRY commands and storcli commands hang while getting adapter information.(SCGCQ01458388)
- pl: NVMe: issues related to port enable completion.(SCGCQ01464247)
- PL: Modify internal structures.(SCGCQ01487864)
- Intermittent Update firmware failed with M0 using EFI StorCLI.(SCGCQ01487866)
- Global HDD LED may not indicate IO activity for NVMe or SAS drives.(SCGCQ01489030)
- Code Unstable in Common_Main, Re definitions of Macro IOP_TIMED_CONDITION, consolidating them.(SCGCQ01489981)
- 0x7C41 Fault doing IOs and Task Managements on a mixed SAS/NVMe topology..(SCGCQ01494379)
- pl: SATA: port enable may time out on spinup failure.(SCGCQ01496842)
- IOP MCTP: Changes missing from a previous code change.(SCGCQ01497080)
- Fixing coverty defects 19848 & 19838.(SCGCQ01504066)
- Ventura: Slot LEDs on SGPIO based backplane may not blink.(SCGCQ01505392)
-.(SCGCQ01615484)
- PL: More than one ATA command at a time may be submitted to a SATA device.(SCGCQ01377242)
- Drive missing on power cycle.(SCGCQ01421447)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated.(SCGCQ01450475)
- vSES Target: Allocation Length less than 16 Bytes for REPORT LUNS Command is not Handled Properly.(SCGCQ01451022)
- MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN.(SCGCQ01631826)
- MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events.(SCGCQ01742362)
- Ventura: NVMe Target: Non-Zero Value in TRACK SKEW FACTOR field of FORMAT DEVICE Mode Page.(SCGCQ01412908)
- (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct..(SCGCQ01638248)
- Negotiated Link Speed for the vSES target is displayed as 'Unknown'..(SCGCQ01606720)
- Not all NVMe drives were discovered after server cold or warm boot.(SCGCQ01664963)
- Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes..(SCGCQ01671177)
- VPD is not shown by lspci.(SCGCQ01687750)
- Not all NVMe drives discovered as part of hot plug operation.(SCGCQ01697329)

EnhancementRequests (40)
- Ventura: Remove VENTURA_PORTING from ARM Initialization/Utilities..(SCGCQ00922893)
- Ventura: Move firmware update copy process to main firmware to avoid PCE problems.(SCGCQ01230723)
- Ventura/Marlin: When the SPICO code fails checksum, Patch SPICO Signature and Checksum.(SCGCQ01240422)
- pl: NVMe: support for devices with large sector sizes.(SCGCQ01275066)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- Ventura: Enclosure Mgmt optimizations and enhancements.(SCGCQ01328437)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- Ventura B0:(UBM) Identifying a UBM Capable backplane.(SCGCQ01412194)
- To read the port Capabilities from backplane implementing UBM and to validate backplane configuration.(SCGCQ01412195)
- Enable I2C polling for drive presence detection in UBM backplanes with NVMe support..(SCGCQ01412198)
- Controlling Slot Locate/Fault LEDs in a backplane which implements UBM..(SCGCQ01412209)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- pl: NVMe: NVMe task management modifications.(SCGCQ01419083)
- Ventura: NVMe 1.3 Support: Firmware Update Granularity.(SCGCQ01430672)
- Ventura: NVMe 1.3 Support: Namespace Optimal IO Boundary.(SCGCQ01430674)
- Ventura: NVME 1.3 Support: Add new Status Codes to header files.(SCGCQ01434061)
- pl: NVMe: don't require a resource frame for some SCSI-NVMe translations.(SCGCQ01436612)
- pl: NVMe: SGL translation performance tweaks.(SCGCQ01440247)
- PL: Add firmware support for depopulation of SATA drives.(SCGCQ01445877)
- pl: NVMe: NVMe task management modifications (part 2).(SCGCQ01445903)
- Reduce time taken by host to initialize one SATA drive..(SCGCQ01448575)
- (SATA Only) Add support for SCSI Read Capacity command when drive is in spun down mode..(SCGCQ01448576)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- (SATA Only) Add support for NDOB bit in translation of SCSI Write Same Command to SATA drives.(SCGCQ01454125)
- Ventura: Re-order pl dbg to put most useful, less verbose prints first.(SCGCQ01454612)
- Ventura/Marlin: Change to ARM site licenses.(SCGCQ01461714)
- Ventura: Change iopiDiagCmdReadMem() to not print rows of zeros.(SCGCQ01462690)
- Ventura: Modify plDiagCmdShowRegister() to skip printing of dwords of 0 when regSize == 4..(SCGCQ01464914)
- PL: Add NVDATA option to gracefully handle invalid BP Type configurations.(SCGCQ01464951)
- pl: backend PCIe: reduce firmware initiated PCIe transaction wait time.(SCGCQ01465016)
- pl: NVMe: add debug print to the NVMe encapsulated failure path.(SCGCQ01487366)
- Ventura: Remove VENTURA_PORTING from Makefiles and headers.(SCGCQ00922883)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
- pl: NVMe: IO breakup structure modification.(SCGCQ01431067)
- Skipping additional reserved registers when printing pl dbg trace.(SCGCQ01468138)
- PL: Use Sense Data from SATA Log Page 10 when querying Log Page 10.(SCGCQ01459375)
- Reduced amount of data in pl dbg trace output.(SCGCQ01394882)
- Ventura/Marlin: Add support for Winbond 256Mbit SPI FLASH.(SCGCQ01449325)

CSETActivities (88)
- PL : Drives may not spin up due to bug in spin up path found during code walk through.(SCGCQ01385320 port of SCGCQ01358138)
- PL: Change avoid duplicate mid LUN reset option to abort task set.(SCGCQ01429867 port of SCGCQ01429655)
- PL: More than one ATA command at a time may be submitted to a SATA device(SCGCQ01435779 port of SCGCQ01377242)
- Ventura VSES: Unique id and serial number for virtual SES to support microsoft storage spaces direct(SCGCQ01436959 port of SCGCQ01404241)
- Ventura vSES: SAS and SATA direct attached devices are not getting associated to vSES in Windows Storage Spaces Direct..(SCGCQ01442629 port of SCGCQ01438119)
- Ventura B0: Missing signing supported firmware image in RO(SCGCQ01443281 port of SCGCQ01392675)
- PCI SIG Compliance Test Failure - Test 1_8 Virtual Channel(SCGCQ01443732 port of SCGCQ01394426)
- Direct attached VSES Enclosure validation may fail with certain OS tools(SCGCQ01451190 port of SCGCQ01445053)
- MCTP I2C: I2C communication is lost between BMC and controller(SCGCQ01455876 port of SCGCQ01385782)
- PL : PWR_GRANT is not issued upon PWR_REQ from SPL2 drive(SCGCQ01458074 port of SCGCQ01330984)
- PL : PL fault 0x7C72 is hit during discovery when disabling and enabling all the PHYs connected to legacy SAS drives(SCGCQ01458664 port of SCGCQ01455200)
- Limit printing a SGL chain to only 15 elements(SCGCQ01468156 port of SCGCQ01180961)
- PL: Add Code to Correctly Determine Mid for Rx Context Non-automated Interrupts(SCGCQ01479502 port of SCGCQ01472512)
- IOP: 0x265D Fault Observed on Cold Boot of Customer Server with Misconfigured Controller NVDATA(SCGCQ01505077 port of SCGCQ01473138)
- PL SATL: SCSI Write Buffer Mode 7 Command Incorrectly Failed by Firmware(SCGCQ01505080 port of SCGCQ01498114)
- IOP: I2C MCTP: Slave response mode fails to return response to I2C read(SCGCQ01508067 port of SCGCQ01506883)
- Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01514262 port of SCGCQ00856085)
- pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01519802 port of SCGCQ01518343)
- pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01522511 port of SCGCQ01487423)
- pl: backend PCIe: 4311 fault with NVMe enabled (part 2(SCGCQ01523550 port of SCGCQ01523531)
- pl: backend PCIe: non-NVMe endpoint not cleaned up on removal(SCGCQ01529383 port of SCGCQ01516968)
- PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB(SCGCQ01529512 port of SCGCQ01509770)
- PL Fault 0000ecdd LR 01403837 during initial discovery(SCGCQ01539840 port of SCGCQ01531770)
- pl: backend PCIe: switch attached discovery takes too long(SCGCQ01556426 port of SCGCQ01522343)
- (SATA Only) SCSI Unmap command to some SATA drives are timing out(SCGCQ01621120 port of SCGCQ01539572)
- (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command(SCGCQ01713180 port of SCGCQ01681441)
- PL Discovery: After Port Down, Expander Is Not Removed and Firmware Retries SMP Indefinitely(SCGCQ01411982 port of SCGCQ01295414)
- MCTP I2C: I2C traces shows partial response/zero’ed out packet response from the HBA(SCGCQ01421231 port of SCGCQ01394463)
- pl: backend PCIe: ECE4 fault(SCGCQ01434062 port of SCGCQ01312345)
- 0x6004 Fault during TM injection while running IO to Sata SSDs(SCGCQ01437146 port of SCGCQ01416481)
- When disabling one phy of a port the other phys of the same port do not relink after reset(SCGCQ01439512 port of SCGCQ01418575)
- Ventura SBR: Changes to PLL reset requirements cause lock failure on some boards(SCGCQ01440390 port of SCGCQ01373888)
- Customer experiences 5-7 % performance drop on 24 direct connected SAS SSD R10/R6 setup(SCGCQ01442980 port of SCGCQ01417361)
- PL: Change avoid duplicate mid LUN reset option to abort task set(SCGCQ01444118 port of SCGCQ01429655)
- Ventura vSES: SAS and SATA direct attached devices are not getting associated to vSES in Windows Storage Spaces Direct(SCGCQ01451982 port of SCGCQ01438119)
- pl: port enable may fail to complete if an OEM backplane is attached(SCGCQ01467289 port of SCGCQ01455680)
- PL owned mids are not getting released even after removing drives (SATA(SCGCQ01512617 port of SCGCQ00846818)
- Ventura hardware does not like the IOP enable method used here(SCGCQ01519729 port of SCGCQ01514880)
- (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices(SCGCQ01524353 port of SCGCQ01516277)
- Controller is not detecting in the storelib, after changing the mode from "set mode oob" command(SCGCQ01530310 port of SCGCQ01494018)
- pl: NVMe: EC0D fault(SCGCQ01533267 port of SCGCQ01530402)
- pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment(SCGCQ01556893 port of SCGCQ01540226)
- To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01628440 port of SCGCQ01507506)
- The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628452 port of SCGCQ01623437)
- PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01639906 port of SCGCQ01505468)
- Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01681401 port of SCGCQ01670965)
- PL : performance drop of nearly 40% in sequential write and seqential Reads(SCGCQ01341898 port of SCGCQ01333993)
- pl: NVMe: memory leak in Verify (10/12/16) command translation(SCGCQ01434063 port of SCGCQ01429659)
- 9405W-16i xml not available in Latest Release Order(SCGCQ01434399 port of SCGCQ01429439)
- Customer experiences 5-7 % performance drop on 24 direct connected SAS SSD R10/R6 setup..(SCGCQ01442976 port of SCGCQ01417361)
- Ventura/Marlin: NMI due to Host-side PCE credit starvation when there are simultaneous accesses to MSIX table and Generic Messaging Queue.(SCGCQ01445831 port of SCGCQ01418686)
- Direct attached VSES Enclosure validation may fail with certain OS tools.(SCGCQ01451191 port of SCGCQ01445053)
- PL: EnclMgmt: Move ownership of SES Page 0x0A slot mapping from devices to PHYs.(SCGCQ01458359 port of SCGCQ00870423)
- VSES Target not added in host if event replay slot ordering is enabled(SCGCQ01474945 port of SCGCQ01471601)
- BMC emulator on Ventura failed with Storlib discovery(SCGCQ01488146 port of SCGCQ01410607)
- Enhance SAS3 FW to pass PCIeCV PCIe Configuration Validation TD_1_28 Vital Product Data Capability Test(SCGCQ01499168 port of  SCGCQ00878239)
- Ventura VSES: Unique id and serial number for virtual SES to support microsoft storage spaces direct(SCGCQ01500100 port of SCGCQ01404241)
- pl: backend PCIe: 4311 fault with NVMe enabled(SCGCQ01520574 port of SCGCQ01514521)
- (SATA Only) Security Protocol In command complete without data transfer for allocation length not a multiple of 512(SCGCQ01524638 port of SCGCQ01275335)
- pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset(SCGCQ01527219 port of SCGCQ01526236)
- Fixing the issues during bringup of the universal backplane(SCGCQ01599610 port of SCGCQ01522148)
- Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01698231 port of SCGCQ01619417)
- pl: Mode Select translation transfer length validation(SCGCQ01439510 port of SCGCQ01435884)
- Ventura: Misc tri-mode backplane mgmt detection fixes and Slot status update changes(SCGCQ01441077 port of SCGCQ01428718)
- vSES Target: Incorrect Sense Data for REQUEST SENSE Command(SCGCQ01500101 port of SCGCQ01451678)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01530305 port of SCGCQ01450475)
- PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01615056 port of SCGCQ01572062)
- Ventura: NVMe Target: Non-Zero Value in TRACK SKEW FACTOR field of FORMAT DEVICE Mode Page(SCGCQ01444677 port of SCGCQ01412908)
- pl: NVMe: EC26 fault(SCGCQ01453726 port of SCGCQ01451332)
- (VSES) SES INQUIRY commands and storcli commands hang while getting adapter information(SCGCQ01463523 port of SCGCQ01458388)
- Ventura vSES: Direct attached NVME drives are not getting associated with vSES in Microsoft Storage Spaces Direct(SCGCQ01502143 port of SCGCQ01478170)
- To fix issues for back plane configuration validation and LED control for the UBM backplane(SCGCQ01599611 port of SCGCQ01533852)
- IO starvation and performance degradation when using dma Q masking feature(SCGCQ01630921 port of SCGCQ01505074)
- ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA(SCGCQ01684232 port of SCGCQ01639482)
- PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715875 port of SCGCQ01715509)
- PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01749480 port of SCGCQ01520524)
- Avoid releasing I2C bus when I2C operation(Read/Write) in progress(SCGCQ01752794 port of SCGCQ01721931)
- Ventura/Marlin: NMI due to Host-side PCE credit starvation when there are simultaneous accesses to MSIX table and Generic Messaging Queue(SCGCQ01448302 port of SCGCQ01418686)
- To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01599612 port of SCGCQ01542497)
- Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01599616 port of SCGCQ01574224)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01456658 port of SCGCQ01450475)
- To fix the LED issue, VPP data and moving to change detect poll state( SCGCQ01599614 port of SCGCQ01576165)
- Change detect feature support on UBM supported back plane(SCGCQ01628442 port of SCGCQ01605371)
- Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676884 port of SCGCQ01670180)
- Hot plugged NVMe drive fails to link up on OEM backplanes with ISTWI drive presence polling enabled(SCGCQ01464097 port of SCGCQ01463496)
- Ventura VSES: Incorrect data in diagnostic page 0xA when drive is missing but not yet removed(SCGCQ01502175 port of SCGCQ01472941)
 - pl: backend PCIe: 4311 fault (part 3)(SCGCQ01574923 port of SCGCQ01537791)
- The x4 link configuration was not detected by UBM module(SCGCQ01747034 port of SCGCQ01735485)


Version 5.01-07-1-1
---------------
Contains:
    BIOS            Firmware      UEFI Driver
    9.9.0.0         5.125.2.0     5.0.0.0


Version 2.08 -  New Function Only/No fixes
---------------
Contains:
  BIOS         Firmware      UEFI Driver
  9.01.03.00   01.125.16.00  01.04.00.00





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA



ThinkSystem 430-x SAS/SATA 12Gb HBA Firmware and BIOS Update

Supported Adapters:  
             ThinkSystem 430-8i SAS/SATA 12Gb HBA
		     ThinkSystem 430-16i SAS/SATA 12Gb HBA
		     ThinkSystem 430-8e SAS/SATA 12Gb HBA
		     ThinkSystem 430-16e SAS/SATA 12Gb HBA
             ThinkSystem 430-8i  SAS/SATA 12Gb Dense HBA

NOTE TO SERVICE - Reference RETAIN #N/A

Version 3.03-06
---------------
Contains:
    BIOS            Firmware      UEFI Driver
    9.05.00.00      3.125.11.00   03.01.00.00


Version 2.08 -  New Function Only/No fixes
---------------
Contains:
  BIOS         Firmware      UEFI Driver
  9.01.03.00   01.125.16.00  01.04.00.00





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

LSI HBA and HBA/LSI Onboard 12Gb SAS/SATA/SSD Driver for Linux RHEL7



12Gb HBA SAS/SATA/SSD Driver for Linux

Supported Controllers: 
 - N2215 SAS/SATA HBA (47C8676)
 - N2225 SAS/SATA HBA (00AE912)
 - N2226 SAS/SATA HBA (00AE916)
 - ThinkSystem 430-8i SAS/SATA 12Gb HBA
 - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
 - ThinkSystem 430-16i SAS/SATA 12Gb HBA
 - ThinkSystem 430-8e SAS/SATA 12Gb HBA
 - ThinkSystem 430-16e SAS/SATA 12Gb HBA

Supported Kernesls:  7.6    
                     7.5    3.10.0-862 
                     7.4    3.10.0-693
                     7.3	3.10.0-514
			         7.2 	3.10.0-327
		             7.1 	3.10.0-229
					 
version	27.125.01.00-1	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
IR/IT (MPT3) – Ph 16 (new)
					 
Defects
- Driver load fails on big endian systems (SPARC64).(SCGCQ01836661)
- Fix, False timeout prints for ioctl and other internal commands during controller reset.(SCGCQ01555936)
- Ventura: As per MPI spec use Supplemental Reply Post Host Index Register(combined reply queue) when MSI-X vectors > 16.(SCGCQ01629402)
- Fix compilation error for SLES11.(SCGCQ01698115)
- Driver compilation fails on latest upstream kernel(>= v4.17), due to changes in "queue_flag_set_unlocked" API.(SCGCQ01799543)
- Code refactor: memory allocation,setting status for incorrect command,accesing dev struct after decrementing its ref count.(SCGCQ01558459)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01615533 port of SCGCQ01473904)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01856662 port of SCGCQ01784898)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconds.(SCGCQ01868049 port of SCGCQ01867387)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is going on.(SCGCQ01905582 port of SCGCQ01819327)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01729592 port of SCGCQ01639219)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01763013 port of SCGCQ01741671)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode.(SCGCQ01905585 port of SCGCQ01875700)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01906874 port of SCGCQ01473904)

EnhancementRequests:
- OS driver support for Oracle Linux 7.5 - SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01586104)
- Added support for RHEL6.10 GA(2.6.32-754.el6).(SCGCQ01828835)
- Skip pending I/Os issued to NVMe drives while processing Broadcast Async Event.(SCGCQ01558613)
- mpt3sas: Do not wait for IOC to become operational if HBA is unplugged.(SCGCQ01681422)
- OS driver support for XenServer7.4 SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01750033)
- Upstream mpt3sas: scsi_transport_sas: switch to bsg-lib for SMP passthrough.(SCGCQ01606945)
- Upstream mpt3sas: Fix function prototypes for module_param_call(SCGCQ01607482)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01719072)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Upstream: mpt3sas: clarify mmio pointer types (Fix compiler warning).(SCGCQ01686081)
- Phase8: Fix sparse warnings of inhouse mpt3sas driver.(SCGCQ01729697)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- mpt3sas: Added new thread called hot plugged watchdog which will poll for whether HBA device is unplugged or not.(SCGCQ01681425)
- mpt3sas: code refactor - move section of code which waits for IOC to be in operational state into a separate function.(SCGCQ01681420)
- Linux IT Ph6 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01839348)
- Upstream mpt3sas: fix dma_addr_t casts.(SCGCQ01541636)
- Added support for XenServer 7.3 OS.(SCGCQ01554011)
- OS Driver Support for Ubuntu 18.04- SAS3.5 PH 8 / SAS3 PH 16.(SCGCQ01586127)
- Upstream mpt3sas: Do not mark fw_event workqueue as WQ_MEM_RECLAIM.(SCGCQ01686075)
- mpt3sas: wait for and flush running commands on shutdown/unload (Upstream Patch).(SCGCQ01686096)
- Change attribution language from Avago to Broadcom and update copyright end year.(SCGCQ01757358)


version	27.125.01.00	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	

					 
version	25.125.02.00	 -- Moderate Impact/Low Probability of Occurrence
-------------------		
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)	

			
version	25.125.01.00-3	 -- Moderate Impact/Low Probability of Occurrence
-------------------
the package support os rhel7.5.	

		
Defects (15)
- Update code to free intended memory pool.(SCGCQ01488145)
- Memory leak when unloading driver with NVMe flashed SAS35 controller in the system.(SCGCQ01497725)
- Memory leak, after cable pull and push of SAS/SATA drives with DMD set.(SCGCQ01509274)
- Workaround in driver to post 64bit request descriptor to register at offset 0xC0/0xC4 to avoid hitting HW bug.(SCGCQ01514520)
- use scsi_internal_device_block_nowait for RHEL distros greater than RHEL7.3.(SCGCQ01526190)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01473904)
- Driver fails to load post installation..(SCGCQ01458946)
- Fix Timeout value and Reset method used for Target Reset issued on internal command Timeout. (Code Review fix).(SCGCQ01473759)
- Controller fault state 265d while loading latest merged driver for SAS2 card.(SCGCQ01471650)
- Remove logically dead code.(SCGCQ01488142)
- OS crashes when drives are hot plugged while loading driver.(SCGCQ01494556)
- Memory leak seen after using storcli and unloading the driver.(SCGCQ01479414)
- NVMe task management command is not executed as per NVDAT settings.(SCGCQ01524245)
- wrong sizeof argument being passed to sizeof() function..(SCGCQ01484567)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01496368)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01615533 port of SCGCQ01473904)
- mpt3sas: Disable DIX support by default..(SCGCQ01465762 port of SCGCQ01465665)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01504666 port of SCGCQ01496368)
- IO Timeouts observed while running IO and parallel TaskMgmt test with SATA drives	.(SCGCQ01522289 port of SCGCQ01497972)	

EnhancementRequests (8)
- Driver support for OEL 7.4_UEK (4.1.12-94.3.9.el7uek).(SCGCQ01396745)
- Report Package Version from HBA Driver.(SCGCQ01445879)
- Upstream mpt3sas: Fix memory allocation failure test in 'mpt3sas_base_attach()'.(SCGCQ01454958)
- Upstream mpt3sas: Create two versions of scsi_internal_device_unblock().(SCGCQ01447644)
- Upstream mpt3sas: fix format overflow warning.(SCGCQ01454955)
- NVMe Task Management - Controller Reset Support (SCS).(SCGCQ01445901)
- Added support for RHEL7.5 GA (3.10.0-862.el7)..(SCGCQ01749948)
- Upstream mpt3sas: Split scsi_internal_device_block(SCGCQ01447640)

			
version 24.125.01.00 -- Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Marlin B0: OS crashed while running Diag reset with IOs.(SCGCQ01311474)
- Buildkit is modified to install Out of box rpm also in '/lib/modules/4.4.0+2/updates' and also RPM naming convention has been changed to match the inbox driver naming convention.(SCGCQ01318375)
- Disable ASPM for MPI2 controllers.(SCGCQ01329184)  
- RHEL 6.8 32 Bit is hitting kernel panic after loading Phase5.0 PA-3 Driver for IT Ventura Controller.(SCGCQ01418569)
- call-trace observed on RHEL6.x while unloading driver.(SCGCQ01336601)
- Ph4 IT Linux mpt3sas: Observing kernel panic during topology configuration w/ blk-mq enabled.(SCGCQ01351060)
- Ventura Phase5: OS crash while removing the drives connected to the controller.(SCGCQ01386942)
- Linux IT SAS3.5 Phase5 mpt3sas: Observing MCE errors while upgrading the Firmware.(SCGCQ01440053)
- Code Review defect: Don't send sync cache and SSU to FW, when pci_error_recovery or adapter_over_temp is set.(SCGCQ01341910)
- mpt3sas: Avoid sleeping in interrupt context.(SCGCQ01329329)
- Linux IT sas35 Phase5 mpt3sas: FW events sent before diagnostic reset are not getting cleaned up during reset.(SCGCQ01397582)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01473904)
- Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01436811)
- Fixed - Sync cache command failure with hostbyte=DID_NO_CONNECT during driver unload.(SCGCQ01291425)
- Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391926)
- Fix for file system going to read-only mode when controller is resetted.(SCGCQ01315476)
- Fix SAS drives going for Spin Down when module param allow_drive_spindown is set to 3.(SCGCQ01337377)
- Driver Unload command does not exit when connected drives are disconnected while unloading driver.(SCGCQ01403879)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01496368)
- Linux IT Ph14 mpt3sas: Observed kernel panic while performing shutdown operation followed by immediate PCI device hotplug.(SCGCQ01380972 port of SCGCQ01348068)
- Linux IT Ph14 mpt3sas: Observed kernel panic during HBA hot plug operation just before issuing system shutdown operation.(SCGCQ01380973 port of SCGCQ01366025)
- Linux IT Ph14 mpt3sas: Poweroff command fails to shutdown the host post surprise removal of controller.(SCGCQ01380975 port of SCGCQ01352902)
- Linux : Enclosure Handles are not updated for SAS device during diag reset.(SCGCQ01372661 port of SCGCQ01326058)
- Linux IT Ph14 mpt3sas: Added Hot-Plug Surprise removal support on IOCs.(SCGCQ01383826 port of SCGCQ01341334)
- Increase NVMe device queue depth to remove performance bottleneck in the driver.(SCGCQ01316459 port ofSCGCQ01305414)
- Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391990 port of SCGCQ01391926)
- Linux SAS35 Ph3 : By default disable multipath support for SAS3.5 HBA's too.(SCGCQ01316220 port of SCGCQ01301732)
- Linux mpt3sas: Enumeration of drives for OEM specific controller.(SCGCQ01408565 port of SCGCQ01318421)


EnhancementRequests:
- Pre-allocate RDPQ Array at driver boot time.(SCGCQ01297392)
- Ph3 : SLES12 SP3(4.4.73-5) OS support.(SCGCQ01417347)
-0001 - mpt3sas: set default value for cb_idx.(SCGCQ01300828)
-0006 - mpt3sas: always use first reserved smid for ioctl passthrough and second reserved smid for internal scsi io commands.(SCGCQ01300840)
-0007 - mpt3sas: lockless command submission.(SCGCQ01300843)
-0009 - mpt3sas: Enable tag support for all supported kernels.(SCGCQ01300853)
- Added support for XenServer 7.1.(SCGCQ01289850)
- 0005 - mpt3sas: Introduce mpt3sas_get_st_from_smid.(SCGCQ01300838)
- 0008 - mpt3sas: create separate lookup table for NVMe PRP list.(SCGCQ01300851)
- Optimize I/O memory consumption in driver.(SCGCQ01388190)
- Enhanced handling of DMA allocation, If the allocation does not fit within same 4GB.(SCGCQ01388961)
- Added mpt3sas driver support for OEL6.9.(SCGCQ01289003)
- 0003 - mpt3sas: separate out _base_recovery_check.(SCGCQ01300833)
- Reducing the number of times enclosure config page read request sent by driver.(SCGCQ01357382)
- Increase event log buffer to support 24 port HBA's to avoid buffer overflow.(SCGCQ01368517)
- 0004- mpt3sas: open code _scsih_scsi_lookup_get.(SCGCQ01300836)
- Added mpt3sas driver support for RHEL6.9.(SCGCQ01316324)
- Added support for SAS Device Discovery Error Event.(SCGCQ01354911)
- OS Support for RHEL 7.4 (3.10.0-693.el7).(SCGCQ01415978)
- 00010 - mpt3sas: allocate as many chains as needed and remove chain list maintenance overhead.(SCGCQ01300854)
- Ph5 : SLES12 SP3(4.4.73-5) OS support.(SCGCQ01396754)
- 0002 - mpt3sas: use list_splice_init.(SCGCQ01300832)
- Upstream mpt3sas: switch to pci_alloc_irq_vectors.(SCGCQ01367469)

			
			
Version 22.00.01.00 - Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Unable to achieve product targets performance numbers with SAS devices (SCGCQ01175998)
- SATA drive will be in blocked state if diag reset occurs while any ATA Passthrough command is outstanding (SCGCQ01221454)
- Target number for vSES is incremented after host reset (SCGCQ01255996)
- fix hang on ata passthru commands (SCGCQ01255965)

Enhancements:
- Block the drive after recieving any ATA pass-though command for that driver and unblock it after completion of the command (SCGCQ01218960)
- Reduce memory footrpints in kdump kernel (SCGCQ01237163)
- Recognize and act on IO's iopriority info (SCGCQ01237164)
- Added driver support for Dual/multi-path typologies (SCGCQ01237381) 
			
Version 14.00.00.00 - Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Fixed an issue where the OS would crash after installing device driver. (SCGCQ01123902)
- Fixed an issue where only 8 MSIX vectors were enabled for SAS3 HBAs on a 32 core machine even though 32 msix vectors could be enabled on the card, since it has RDPQ enabled firmware. (SCGCQ01106942)

Enhancements:
- Updated initial ref tag with correct value for 4K PI drives in kernels less than 3.18. (SCGCQ01066189)
- Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device. (SCGCQ01100134)
- Set maximum transfer length per IO to 4MB for VDs (SCGCQ01072659, SCGCQ01100150 Port of SCGCQ01072631)
 

Version 13.00.02.00 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
- fixed an issue where the initial ref tag was incorrect with 4K sector size drives when PI is enabled for kernel v3.18 and onwards. (SCGCQ01015654)
- Fixed an issue where partial driver message is displayed when active cable power consumption exception occurs.(SCGCQ01025061)
- Merged mpt2sas driver in to mpt3sas driver module. (SCGCQ00955258)

Enhancement
- Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device (SCGCQ01100134)
- Added support for RHEL6.8. (SCGCQ01093683)
- Active cable exception handling in mpt3sas driver (SCGCQ01008402)
- Set maximum transfer length per IO to 4MB for VDs (SCGCQ01100150)
- Fixed issue where OS not discovering all drives in dual node configuration (SCGCQ01026842 PORT of SCGCQ00776162)
- Updated MPI Headers from 2.00.39 to 2.00.42 (SCGCQ01015128)

Version 12.00.00.00 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
- Fixed potential protection fault due to sas device list corruption (SCGCQ00933587)
- Fixed potential protection fault due to fw event list corruption (SCGCQ00933591)
- Fixed memory leak occuring with failed firmware event data (SCGCQ00881682)

Enhancements:
- Make use of additional HighPriorityCredit number of message frames for sending SCSI IO's (SCGCQ00899842)
- Add support for configurable Chain Frame Size. (SCGCQ00933600, Port of SCGCQ00929253)

Version 10.00.02.00-6 - Moderate Impact/Low Probability of Occurrence
------------------
Enhancment:
- Added support for Red Hat 7 Update 1

Fixes:
- Enabled polling for detecting of SMART SATA drives (SCGCQ00791340)

Note: Installed version number is 10.00.02.00

Version 8.00.00.00-1 - Initial release
------------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

LSI Storage Authority Software for windows and linux



LSI Storage Authority Software

Supported controllers:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 4GB Cache PCIe 12Gb Adapter  
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - N2226 SAS/SATA HBA for Lenovo System x (00AE916)
  - N2225 SAS/SATA HBA for Lenovo System x (00AE912)	 
  - N2215 SAS/SATA HBA for Lenovo System x (47C8676)
  - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110)
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210 SAS/SATA Controller
Supported Operating Systems:
 - SLES 11 SP3/SP4, SLES 12/SP1/SP2/SP3/SP4,SLES 15
 - RHEL 6.7/6.8/6.9/7.1/7.2/7.3/7.4/7.5/7.6
 - Vmware  ESXi  6.5 U1,U2
 - Vmware ESXi ESXi 6.0 U1/U2/U3
 - Vmware ESXi 6.7

NOTE TO SERVICE - Reference RETAIN #N/A

004.189.000.000 - Moderate Impact
---------------

-(SCGCQ01351380) 
 - WG: Physical Drives tab should be aligned in center for Advanced Configuration.(SCGCQ01440777) 
 - Fixed: settings in configuration service API is inconsistent with other applciations(SCGCQ01518134) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01534444) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01539326) 
 - LSA Client 7.6: SPAN drives order is not maintained(SCGCQ01539355) 
 - Client: LSA should handle the not empty check for enclousre field for the physicalDevices response(SCGCQ01555968) 
 - IT-FURY-PH16:LSA-4.126.0.0-Fully Populated Enclosure S/N is "NA" and shown correctly after few drive removals.(SCGCQ01563352) 
 - SCGCQ01565134: IT-Ventura-PH7:LSA-4.126.0.0- FW update fails with error "File size Exceeds 16MB".(SCGCQ01565134) 
 - WG : Server detail is getting populated twice when user is using local IP (127.0.0.1(SCGCQ01565327) 
 - WG: During VD Creation on Simple Configuration, Clicking more than Once on the Finish Button is giving a Wrong Message.(SCGCQ01569262) 
 - WG: Copyright info is shown as 2017 instead of 2018(SCGCQ01571088) 
 - WG:Pop Up scroll missing in case there are more number of VDs to add while setting patrol read properties & Schedule CC(SCGCQ01571089) 
 - WG: User is notified to that multiselect PD/VD displays the properties but it is not supported(SCGCQ01571095) 
 - IT-FURY-PH16:LSA-SATA NCQ bit is always shown as disabled(SCGCQ01571261) 
 - LSA is not responding if online state is changed to offline(SCGCQ01571453) 
 - SCGCQ01571863: WG: LSA installation/uninstallation on linux does not notify the user on success or failure(SCGCQ01571863) 
 - Fixed: Windows OS details were reported as VMware details in Manual Search(SCGCQ01571874) 
 - WG: LSA wrapper indicates the progress of operations appears to be clickable while there is nothing user can select from list(SCGCQ01573087) 
 - SCGCQ01575706: WG:LSA installation exits on invalid option for selecting range of LSA events, it asks for retry with options listed again(SCGCQ01575706) 
 - SCGCQ01575999: FURY-PH16:LSA-Model Number is getting truncated for ST3000DM001,Hitachi HDS723020BLA642 models.(SCGCQ01575999) 
 - WG: the string 'status' is displayed multiple times after searching the server for manual addition(SCGCQ01577707) 
 - WG: LSA allows to replace HDD missing drive with SSD UG drive, fails with Partial Success.0 Successful;1 Failed notification(SCGCQ01577769) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01578248) 
 - LSA Server: Removal of Additional Carriage Returns and Line feeds in tty log file(SCGCQ01579290) 
 - WG: Error message on a failed VD creation is displayed outside the allocated space(SCGCQ01586721) 
 - SCGCQ01588880:(SCGCQ01588880) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01590450) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01595641) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01601386) 
 -(SCGCQ01628332) 
 - fixed: Advanced Configuration is grayed out when there are 2 jbods available in the system.(SCGCQ01631267) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01669558) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01675460) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01681070) 
 - WG: LSA 7.7 PA2 Not able to create RAID 00 VDs on iMR Ventura controller(SCGCQ01683638) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01683938) 
 - During migration from r0(opal drives and non-secured) to r1, Add Pd list does not list the available drives (Greater/same si(SCGCQ01687072) 
 - WG: Issues pertaining to searching of the server : manual discovery in list view & GUI issues in the manual discovery panel(SCGCQ01687117) 
 - MR7.7_LSA: Unable to convert JBOD to UG when filesystem is present(SCGCQ01697980) 
 - LSA Linux doesn't have latest storelib(SCGCQ01713580) 
 - WG MR 7.7 PA2: LSA allows to add FDE and OPAL drives to create Encrypted volume(SCGCQ01721222) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01761801) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01761830) 
 - Fixed: nvme is allowed to mix with sas /sata(SCGCQ01762948) 
 - SCGCQ01763132: LSA: Alert Configuration response contains unsupported character(SCGCQ01763132) 
 - Foreign Config preview should show the VD details also(SCGCQ01788639) 
 - LSA Opal: RLM mixing for Opal SSC and Enterprise shouldn't be allowed when enableFDETypeMix=0(SCGCQ01790063) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) 
 - compilation error in server(SCGCQ01817434) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01841473) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856350) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - WG: LSA shows incorrect popups while making the drive from offline to online & vice versa(SCGCQ01922610) 
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01937406) 
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971368) 
 -(SCGCQ01542415) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01552654) 
 - Correcting the library version display, ini file contents and also the readme files contents.(SCGCQ01561849) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01564526) 
 - SWR: Device ID is not displayed in LSA.(SCGCQ01564621) 
 - MR/IR: Controller Device ID value mismatch in LSA(SCGCQ01564622) 
 - WG:LSA and web server port have references of SLIM and nignx in notification if invalid ports are given during LSA installatn(SCGCQ01571099) 
 - WG: Issues pertaining to replace drive confirmation popup(SCGCQ01573101) 
 - Security related information should not be displayed in IR/IT for LSA(SCGCQ01577891) 
 - LSA allows user to assgin a 512 B drive as replacement to 4k missing drive in a DG(SCGCQ01591175) 
 - SCGCQ01593058: Add non printable character support for sata pd product id display(SCGCQ01593058) 
 - Add a provision to indicate VMware/NonVmware server in Manual Discovery Panel(SCGCQ01600706) 
 - LSA WG FURY IT: UEFI image download is failing in LSA(SCGCQ01616545) 
 - LSA 7.6 Server: LSA is showing the option for PD:"Undo Prepare For Removal", when the DG is in TR state(SCGCQ01618243) 
 - Not able to create secure VD with latest MR 7.7 LSA 177.000.000-SCGCQ01664972 but OK with previous version(SCGCQ01665121) 
 - Error observed while adding Windows gateway server in through manual discovery(SCGCQ01675601) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01677101) 
 - LSA MR7.7 PA2: Previously cleared configuration is seen in presence of OPAL foreign drive in Jbod Mode.(SCGCQ01685488) 
 - WG MR7.7 PA2:Once the 69639 error code is seen in LSA, performing every valid operation fails until manual refresh is perfo(SCGCQ01686013) 
 - WG MR 7.7:There is no import option for GHS Foreign device in LSA(SCGCQ01698105) 
 - Fixed: LSA handle count increase was observed(SCGCQ01713154) 
 - Add physical Drives page is not consistent across (Advanced Configuration and Modify drive Group(SCGCQ01716606) 
 - LSA: Handle Opal drive scenario for Hotspare and replace drive(SCGCQ01719043) 
 - LSA client: Add support to show incompatible profiles details(SCGCQ01727270) 
 - Add SCSI Unmap property at PD level(SCGCQ01732785) 
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01745770) 
 - WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile(SCGCQ01747490) 
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline.(SCGCQ01752969) 
 - [CISCO][TR]"Clear Transport Ready" option on rebuild LD should be removed or greyed out in LSA(SCGCQ01753229) 
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01761269) 
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01763742) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813078) 
 - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01833469) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01838943) 
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01886563) 
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01918692) 
 -(SCGCQ01534450) 
 - LSA needs to change "Error code" : 86017, Description:Operation failed because of a resource reservation error" to proper mes(SCGCQ01556013) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01581943) 
 - SCGCQ01582139: MR7.6_LSA: Enclosure ID and Device ID is shown blank in LSA event logs(SCGCQ01582139) 
 - WG: LSA Page auto scrolls down with scheduler wrapper going out of focus. LSA page would now be only half transparent(SCGCQ01586697) 
 - PH7 LSA WG Ventura: Sorting the drives on the basis of Device ID is not working fine(SCGCQ01587630) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01593855) 
 - WG: Instance validation failed for controller GET(SCGCQ01601458) 
 - WG: Minor text changes to be made in user information when no rows are selected in PD tab / DG tab / other hardware tab(SCGCQ01601656) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01615856) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01638193) 
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress(SCGCQ01680714) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01685449) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01686024) 
 - Instant Secure Erase does not work in VMware when schedule is enabled(SCGCQ01686028) 
 - MR7.7_LSA: Error code:0 is observed when driver security is changed in LSA(SCGCQ01686050) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716622) 
 - fixed: max pd is a bigger number than the actual allowed max pd per raid level(SCGCQ01746200) 
 - WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection(SCGCQ01764794) 
 - WG: gateway system is not discovering systems with different web port number in remote discovery page.(SCGCQ01788630) 
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives)(SCGCQ01803743) 
 - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01809413) 
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) 
 - fixed: Info "1920 more drives can be added" need to change in LSA(SCGCQ01827401) 
 - The display wrong location in page(SCGCQ01836732) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01355833) 
 - WG: Changing the drive security key with invalid authentication key results in notification that is not in format(SCGCQ01573090) 
 - WG: Raid 00 DG having missing drives Span list dissapears when user tries to sort the drives based on capacity(SCGCQ01577833) 
 - MR 7.7: LSA did not allow to pick all SED/FDE but OK to pick one by one when create secure VD(SCGCQ01629062) 
 - SCGCQ01718994: LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01718994) 
 - When there is pending personality, do not allow behavior Mode change, GUI refresh issue(SCGCQ01731312) 
 - Assign DHS is not showing any message in failure case(SCGCQ01732485) 
 - To enable the Alarm user has to click on the bottom of checkbox(SCGCQ01740783) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01818960) 
 - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives(SCGCQ01850008) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) 
 - LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01533554) 
 - WG: change Behavior Mode From JBOD to None is Not Working until closing the window(SCGCQ01635541) 
 - WG MR7.7PA2:In Jbod mode after first reboot and after converting Jbod to UG, advance configuraton leads to Jbod table.(SCGCQ01683001) 
 - MR 7.7 PA2: LSA does not refresh DG icon when PDs are made offline to online and visa versa.(SCGCQ01686029) 
 - WG MR 7.7 PA2:Encrypted Opal drive VD supports the Opal drive replacement with FDE drive(SCGCQ01697265) 
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button(SCGCQ01737550) 
 - MR 7.7 alpha: LSA displays raid 1 as raid 1E when created using 4 drives.(SCGCQ01764771) 
 - SCGCQ01564386: IT-FURY-PH16:Drives are not listed under Enclosures ( "0" drives) under other Hardware if connected in Multipath.(SCGCQ01564386) 
 - Coverity Defect fix in 7.7 Stream(SCGCQ01682365) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01714415) 
 - Client changes for defect SCGCQ01629703(SCGCQ01714659) 
 - MR7.7_LSA: After disabling PR, PR properties shows next scheduled time(SCGCQ01718119) 
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG(SCGCQ01803722) 
 - LSA is not locating all drives correctly(SCGCQ01924674) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01515496) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01563343) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01629574) 
 - Fixed: Show Advanced Config menu only if Unconfigured UG is present(SCGCQ01629703) 
 - WG: Readme shows wrong Version of LSA in html\files\LSA_ReadMe\LSA_Readme(SCGCQ01822525) 
 - SCGCQ01822561: WG: Changed LSA port is not listed after Direct agent installation on Rhel(SCGCQ01822561) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01866289) 
 - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01564627 port of SCGCQ01542412) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01564633 port of SCGCQ01562368) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01564739 port of SCGCQ01545262) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01564943 port of SCGCQ01534444) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565025 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01565116 port of SCGCQ01555955) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01566088 port of SCGCQ01562368) 
 - WG: No success or failure notification is shown on enabling the JBOD drive security(SCGCQ01566435 port of SCGCQ01511274) 
 - SCGCQ01545384: Installation of LSA with LWM option is showing installation_type = 0, in the LSA.conf file(SCGCQ01567110 port of SCGCQ01545384) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569267 port of SCGCQ01504080) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01569465 port of SCGCQ01542412) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01569474 port of SCGCQ01539349) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01569949 port of SCGCQ01563340) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01570203 port of SCGCQ01550970) 
 - Enclosure's physicaldevices URI getting failed with 405 error(SCGCQ01589492 port of SCGCQ01523122) 
 - Label of the user menu drop down should change reinforcing that selection worked.(SCGCQ01597876 port of SCGCQ01493942) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01599402 port of SCGCQ01563340) 
 - Version changes for LSA 4.129 common project(SCGCQ01601148 port of SCGCQ01601146) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601603 port of SCGCQ01598515) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01604992 port of SCGCQ01564526) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01605344 port of SCGCQ01581943) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01609343 port of SCGCQ01578248) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01614982 port of SCGCQ01355833) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01616555 port of SCGCQ01595641) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01617930 port of SCGCQ01401460) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01628354 port of SCGCQ01504080) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01634072 port of SCGCQ01473733) 
 - WG: few of the alert params have the missing controller ID tag for the events(SCGCQ01635756 port of SCGCQ01625923) 
 - LSAServer: Use scheduler call for heavy operations for performance improvement - PD Operations(SCGCQ01635765 port of SCGCQ01514283) 
 - WG: though the hotspare button will be disabled after adding VD for a Raid 1 DG, the hand cursor button appears(SCGCQ01635778 port of SCGCQ01626738) 
 -(SCGCQ01639457 port of SCGCQ01599526) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01685343 port of SCGCQ01641760) 
 - Raid 1 Volume creation using 4 drives is displayed as Raid 1E(SCGCQ01686231 port of SCGCQ01686106) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687172 port of SCGCQ01686080) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01697468 port of SCGCQ01683941) 
 - LSA fails to flash GPMR2 package 50.1.0-1048 on top of MR 7.6 package 50.6.0-1255 on first try-it is successful on 2nd try(SCGCQ01697485 port of SCGCQ01680521) 
 - LSA not showing the proper time stamp in the schedule PR page(SCGCQ01698028 port of SCGCQ01677008) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01719179 port of SCGCQ01515496) 
 -(SCGCQ01733306 port of SCGCQ01721811) 
 - Fixed: LSA handle count increase was observed(SCGCQ01742153 port of SCGCQ01713154) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01747012 port of SCGCQ01745768) 
 - Server schema validation is failing(SCGCQ01764913 port of SCGCQ01619401) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01764928 port of SCGCQ01638193) 
 - LSA installation failed on SLES15(SCGCQ01784699 port of SCGCQ01760620) 
 - LSA needs proper message for max config import(SCGCQ01789100 port of SCGCQ01763411) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) 
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup(SCGCQ01810649 port of SCGCQ01803341) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813086 port of SCGCQ01813078) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01816649 port of SCGCQ01686080) 
 - C480-M5: LSA downloaded event log needs better decoding(SCGCQ01828830 port of SCGCQ01321211) 
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) 
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab(SCGCQ01851980 port of SCGCQ01851906) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01897266 port of SCGCQ01818960) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01901774 port of SCGCQ01866289) 
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915861 port of SCGCQ01905192) 
 - [CISCO]LSA shows previously set security key (M3g@raid(SCGCQ01921581 port of SCGCQ01878346) 
 - LSA fails to start initialization on EPD if it has DDF(SCGCQ01921583 port of SCGCQ01849522) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) 
 -(SCGCQ01921684 port of SCGCQ01841361) 
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event(SCGCQ01921836 port of SCGCQ01876230) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01538488 port of SCGCQ01473733) 
 -(SCGCQ01564591 port of SCGCQ01515389) 
 - WG: System display uniformity is not there in GUI (Remote server discovery(SCGCQ01567177 port of SCGCQ01553588) 
 - Client: Handle Enable/Disable style for search Button(SCGCQ01567216 port of SCGCQ01539573) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01567307 port of SCGCQ01545262) 
 - Manual discovery of servers(SCGCQ01569264 port of SCGCQ01539471) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569569 port of SCGCQ01504080) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01570076 port of SCGCQ01563340) 
 - Converting the JBOD Pds to Unconfigured good PD during VD creation VD creation(SCGCQ01597581 port of SCGCQ01518204) 
 - Manual discovery of servers(SCGCQ01600837 port of SCGCQ01539471) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01615020 port of SCGCQ01552654) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01615042 port of SCGCQ01601386) 
 -(SCGCQ01633836 port of SCGCQ01599526) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01635183 port of SCGCQ01593855) 
 - Use schedular call for heavy operations for performance imporvement(SCGCQ01635665 port of SCGCQ01506032) 
 - Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01635761 port of SCGCQ01518113) 
 - JBOD Mode : WG: Even after clicking Convert JBOD the JBOD conversion page does not refresh with updated list(SCGCQ01635784 port of SCGCQ01617721) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676612 port of SCGCQ01670094) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676732 port of SCGCQ01670094) 
 -(SCGCQ01685548 port of SCGCQ01685009) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01686054 port of SCGCQ01685449) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687173 port of SCGCQ01686105) 
 - fixed: WG: managing the manually added server fails : windows(gateway(SCGCQ01697195 port of SCGCQ01682360) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716641 port of SCGCQ01716622) 
 -(SCGCQ01718985 port of SCGCQ01698211) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01788477 port of SCGCQ01629574) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880123 port of SCGCQ01876091) 
 - handling the session management(SCGCQ01892868 port of SCGCQ01829897) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01898263 port of SCGCQ01802344) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01901754 port of SCGCQ01827404) 
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives.(SCGCQ01904075 port of SCGCQ01893304) 
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904345 port of SCGCQ01901758) 
 -(SCGCQ01920699 port of SCGCQ01808698) 
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01921839 port of SCGCQ01829669) 
 - SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS(SCGCQ01921842 port of SCGCQ01803373) 
 - WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674) 
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command(SCGCQ01930623 port of SCGCQ01926876) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01557738 port of SCGCQ01539349) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01564629 port of SCGCQ01550970) 
 - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message(SCGCQ01564682 port of SCGCQ01547992) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01569579 port of SCGCQ01514206) 
 - Support from LSA back-end to allow JBODs to be converted to UG for advance VD creation(SCGCQ01597602 port of SCGCQ01519271) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01670841 port of SCGCQ01629821) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01676281 port of SCGCQ01615856) 
 - Server schema validation is failing(SCGCQ01676389 port of SCGCQ01619401) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01679003 port of SCGCQ01563343) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01680728 port of SCGCQ01677101) 
 - LSA taking more time to discover VMWare servers(SCGCQ01681092 port of SCGCQ01681069) 
 -(SCGCQ01697478 port of SCGCQ01685009) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716625 port of SCGCQ01716622) 
 -(SCGCQ01718980 port of SCGCQ01698211) 
 -(SCGCQ01749087 port of SCGCQ01698211) 
 - Modify Properties option is enabled for VDs which are part of Transport Ready Drive Group(SCGCQ01764894 port of SCGCQ01763056) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01826237 port of SCGCQ01761830) 
 - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation(SCGCQ01837378 port of SCGCQ01833791) 
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA(SCGCQ01851919 port of SCGCQ01841280) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856730 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01891168 port of SCGCQ01889547) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD(SCGCQ01897144 port of SCGCQ01817275) 
 - Update the Windows Server 2019 OS name in LSA(SCGCQ01897178 port of SCGCQ01866322) 
 -(SCGCQ01920924 port of SCGCQ01818618) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921819 port of SCGCQ01856350) 
 - LSA 7.6 Client: Cosmetic replace drive selection issue(SCGCQ01566455 port of SCGCQ01539347) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01567176 port of SCGCQ01539326) 
 - WG: Alignment in Remote Server Discovery page changes when it is in List view and filtered with any one of the OS type.(SCGCQ01567193 port of SCGCQ01471834) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569137 port of SCGCQ01538253) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569138 port of SCGCQ01538253) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01569488 port of SCGCQ01540821) 
 - Client:Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01597592 port of SCGCQ01518206) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601608 port of SCGCQ01598515) 
 - WG: empty details for policy change displayed in events "Previous = Current Write Policy: Now = Current Write Policy:"(SCGCQ01635759 port of SCGCQ01625912) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01635779 port of SCGCQ01629821) 
 - TR VD should be excluded from the PR VD list(SCGCQ01677110 port of SCGCQ01677062) 
 - Implemented: Allow mixing of nvme drives to be mixed with SATA/SAS drives(SCGCQ01697042 port of SCGCQ01697026) 
 - Hercules : Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails(SCGCQ01789156 port of SCGCQ01731931) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01816428 port of SCGCQ01641760) 
 - Handling the set text mechanism in client(SCGCQ01886532 port of SCGCQ01850387) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01897181 port of SCGCQ01841473) 
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,(SCGCQ01915812 port of SCGCQ01906914) 
 - LSA 7.8:Import option is given for the Incomplete foreign VD(SCGCQ01921678 port of SCGCQ01865420) 
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01961510 port of SCGCQ01889547) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01697480 port of SCGCQ01681070) 
 - Add Virtual Drive option is available for DGs with Transport Ready feature set(SCGCQ01764885 port of SCGCQ01763052) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01828400 port of SCGCQ01538253) 
 - Fixed: Crash when pressing back button after logout(SCGCQ01892905 port of SCGCQ01865309) 
 - Remove un printable characters from LSA log(SCGCQ01901769 port of SCGCQ01901760) 
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) 
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives(SCGCQ01921580 port of SCGCQ01823858) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565119 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01569761 port of SCGCQ01555955) 
 - Unable to import foreign secured VDs with different security key(SCGCQ01731357 port of SCGCQ01670139) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01794950 port of SCGCQ01793057) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01817915 port of SCGCQ01793057) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01897099 port of SCGCQ01761801) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01564631 port of SCGCQ01540821) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01679329 port of SCGCQ01675460) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01698150 port of SCGCQ01590450) 
 - LSA needs proper message for max config import(SCGCQ01813925 port of SCGCQ01764977) 
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) 
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01564737 port of SCGCQ01514206) 
	
EnhancementRequests:
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399204) 
 - Part 2 of 2: Support TCG Opal 2.0 via SafeStore for VDs and SystemPD (Legacy JBOD) in RAID Mode and JBOD/SDS Modes(SCGCQ01599762) 
 -(SCGCQ01740789) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399205) 
 - Manually add server details to the list of servers(SCGCQ01539514) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01740787) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01401460) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746609) 
 - Manual discovery of servers(SCGCQ01539471) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01802344) 
 -(SCGCQ01599763) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746608) 

004.069.000.000  - Moderate Impact
--------------- 
Defects (20)
-.(SCGCQ01753405)
- Server: LSA GUI Not Updating Security Key Info.(SCGCQ01761801)
- CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275)
- Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404)
- Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01841473)
- LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856350)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209)
- fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01833469)
- LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ01838943)
- LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953)
- fixed: Info "1920 more drives can be added" need to change in LSA.(SCGCQ01827401)
- The display wrong location in page(SCGCQ01836732)
- LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01818960)
- LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives.(SCGCQ01850008)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091)
- Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01866289)
- Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305)
- Security Key Confirm Text box should not accept the copy of anything.(SCGCQ01788477 port of SCGCQ01629574)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856730 port of SCGCQ01856350)
- The LSA is failing to take into account current USED PDs from another configured VD during next VD creation.(SCGCQ01837378 port of SCGCQ01833791)
- SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in.(SCGCQ01828400 port of SCGCQ01538253)
- Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01817915 port of SCGCQ01793057)
- SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895)

EnhancementRequests (20)
- RTTrace API Changes.(SCGCQ01745568)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01802344)


004.062.000.000  - Moderate Impact
--------------
fixed:
Nginx versions since 0.5.6 up to and including 1.13.2 are vulnerable to integer overflow vulnerability in nginx range filter module resulting into leak of potentially sensitive information triggered by specially crafted request.https://nvd.nist.gov/nvd.cfm?cvename=CVE-2017-7529.

Defects (109)
- LSA server report for iMR Inv controller displays dedicatedHotSparePerDriveGroup is 0 under "maxLimit".(SCGCQ01375788)
- SCGCQ01393056: Enclosure ID is coming up as null in LSA.(SCGCQ01393056)
- WG: Error message not fitting inside the message box in "Enable Drive Security" page..(SCGCQ01442477)
- WG: Issues pertaining to 'Make JBOD Secure' Pop up.(SCGCQ01446801)
- PerfImp: Don't handle SLIM_EVT_EXCEEDS_MAX if there is no event requires complete refresh.(SCGCQ01447165)
- WG: UI Pattern in "Virtual Drive Settings" is not uniform while creating and modifying VD properties..(SCGCQ01447697)
- WG: "Change" button shown as disabled when user tries to change Behavior mode..(SCGCQ01450713)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG: success message box for "change personality" does not have proper border.(SCGCQ01453980)
- WG: Event Log table headers needs space - Cosmetic.(SCGCQ01460053)
- WG: Notification after saving the changes in "Manage Power Save Settings" needs cosmetic change..(SCGCQ01460078)
- Requested personality field is not updated for Ventura.(SCGCQ01465642)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)
- WG: Tooltip for help link in "Remote Server Discovery" page is not displayed..(SCGCQ01471842)
- WG: "Available UG drives" form is shown blank when "Type" is selected from ALL to any other drives..(SCGCQ01472186)
- WG: LSA showing inappropriate message after securing a DG using FDE security..(SCGCQ01472201)
- Buttons are inconsistent in Email Settings page of LSA.(SCGCQ01472752)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.().(SCGCQ01474461)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01482320)
- During Advanced Vd Creation PD selection order is not maintained by the client.(SCGCQ01498969)
- Display the ROC temperature in Fahrenheit as well along with Celsius.(SCGCQ01504619)
- WG: Hand mouse pointer is used in " Background Process progress " window , where it shows the name of background operations..(SCGCQ01505999)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Caps letter is expected in Settings for Alert settings successful and restore default value successful message..(SCGCQ01509253)
- WG: Sorting of drives by model number does not work for JBOD drives.(SCGCQ01511247)
- Do not allow the user to manage Personality Panel if set personalty is not supported.(SCGCQ01514527)
- SCGCQ01515443: WG: Typo in Event ID: 114 of PD state Change event related to sheild state.(SCGCQ01515443)
- 502 bad gate way observed on enclosure cable push/pull.(SCGCQ01524150)
- WG : LSA allows to add VD on offline DriveGroup and operation fails anyways.(SCGCQ01526342)
- MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01532725)
- LSA shows wrong diskgroup info when you have foreign PD.(SCGCQ01590450)
- Lenovo_18B: Not able to set max no of PD using set patrol read properties in LSA/Storcli.(SCGCQ01681070)
- Fixed: LSA handle count increase was observed.(SCGCQ01713154)
- Lenovo CIT 18B: LSA Linux doesn't have latest storelib.(SCGCQ01713580)
- SCGCQ01385340: Health is not coming proper after foreign config import..(SCGCQ01385340)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389892)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01419325)
- WG: Not all space in "Foreign Configuration" tab is clickable..(SCGCQ01467702)
- WG: Font style across the "Advanced Configuration" form should be made same..(SCGCQ01472063)
- Removing dead code from LSA7.5 stream..(SCGCQ01472185)
- WG: "Ok" button needs to be in caps in "Mixed listed drives" confirmation page and one more cosmetic change..(SCGCQ01472190)
- WG: There is no alignment for the error message while user changes the personality mode when PR is in progress..(SCGCQ01474932)
- WG: LSA is not allowing User to change No of PD's allowed for Patrol Read in Set PR properties through KeyBoard..(SCGCQ01479402)
- WG: Trying to clear configuration does not show any warning in server summary page regarding cached data, in CC page it shows.(SCGCQ01486698)
- WG: Select all check box is still selected even if one of the drive group is unselected while assigning HSP to existing DG.(SCGCQ01488141)
- WG: while creating FDE VD, type by default is selected as "All" in PD selection pane, unable to select all FDE drives.(SCGCQ01488169)
- Requested personality field is not updated for Ventura.(SCGCQ01494598)
- temperature change in controller is not refeclected in LSA..(SCGCQ01500344)
- Set patrol read window shows a time in past..(SCGCQ01503810)
-.(SCGCQ01508528)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01509259)
- WG: LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01509708)
- LSA Server: Set Patrol read is not shown when the volume is created with SSD.(SCGCQ01511260)
- SCGCQ01513209: WG: Simple configuration tab show invalid options before the raid level drop down list the supported raid levels.(SCGCQ01513209)
- WG : Advanced configuration tab gets disabled after secure erasing the FDE foreign drives.(SCGCQ01514728)
- SCGCQ01521013: MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01521013)
- MR 7.5_LSA: LSA keeps on refreshing during the background operations- Full init, RLM, CC etc.(SCGCQ01522807)
- WG: Behavior mode is missing in "personality management" window..(SCGCQ01523045)
- SCGCQ01525738: MR 7.5_LSA: Wrong nginx version is reported in linux ( SLES and RHEL ) Operating Systems..(SCGCQ01525738)
- Instance validation issues with LSA build 4.55 with IR3 controller.(SCGCQ01528425)
-.(SCGCQ01628332)
- WG: Current Profile is not selected by default in the table that lists the available profiles for the controller..(SCGCQ01442481)
- WG: "%" is accepted along with the input for Expand VD value - But not accepted for all..(SCGCQ01445384)
- WG: Partition line is required in Controller Properties Page..(SCGCQ01445396)
- WG: Status icon of physical drive is not changed after changing the state of the PD from rebuild to offline..(SCGCQ01461144)
- WG:LSA doesn't allow to secure more than one DG using FDE..(SCGCQ01472853)
- SCGCQ01474327: Handle dynamic length serial number as part of serial number VPD page 0x80.(SCGCQ01474327)
- WG: GUI : Cosmetic issues in clear configuration notificationp.(SCGCQ01486692)
- WG: LSA does not notify the user with notification on starting the VD initialization.(SCGCQ01487270)
- WG: able to add VD for scheduling consistency check even after all the VD's have been deselected.(SCGCQ01489509)
- WG:Add physical Drive button is clickable before VD list is loaded while scheduling CC or PR, no notification to user to wait.(SCGCQ01489885)
- LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01489942)
- LSA: Virtual drive, spare and drivegroup is not supported for IT but seen in URI response for Physical drives..(SCGCQ01500099)
- WG: Selection of different drive type is activated after few clicks.(SCGCQ01503786)
- RWC3 launch tab is showing the LSI Storage Authority.(SCGCQ01503896)
- WG : Pop up for securing FDE drive has inconsistency in text.(SCGCQ01507972)
- In settings window "Restore Default Alert settings" button is not saving the default values.(SCGCQ01508002)
- WG: Confirm Check box is not aligned with the "Enable Security" button.(SCGCQ01511250)
- LSA WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01511390)
- WG:Server Logs does not contain status of energy pack it mentions "Requested element not found in the stack.":error "69634".(SCGCQ01512318)
- WG: Spell Check issues with "message_en.js" used for displaying the GUI notification.(SCGCQ01512377)
- Sorting of Event logs wrt View Events and Download Logs.(SCGCQ01512750)
- WG: LSA add physical Disks pane shows empty drive list even if there are 182 drives for adding for RLM operation.(SCGCQ01513656)
- Controller operations schema instant validation is failed.(SCGCQ01514528)
- WG: LSA shows the message "The virtual disk has not been initialized" even when 32 VD's have been selecte.(SCGCQ01521694)
- Lenovo-18B: IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3.(SCGCQ01595641)
- WG: "Virtual Drive expanded successfully" message is still shown even after the page refresh post VD expansion..(SCGCQ01445693)
- WG: Cosmetic changes required in tooltip messages of Configure options in Controller Actions..(SCGCQ01447797)
- WG: Space is required between RAID and it's type in Available UG drives form and one more cosmetic change..(SCGCQ01472194)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- LSA: partial VD hide operation is failing..(SCGCQ01484118)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01506090)
- WG:Launching LSA using ip:2463 in browser, User can see the HOME page flash before redirecting to Remote discovery.(SCGCQ01439795)
- WG: LSA displays empty box instead of "Action Successful" for "Prepare for removal" and "Undo prepare for removal".(SCGCQ01447823)
- WG: "Adding the virtual drive will add the corresponding virtual drives for PR" is not shown when "select all" box is used..(SCGCQ01461133)
- WG: Size of "Back" & "Save" buttons are not same once the user saves the changes after scheduling CC.(SCGCQ01472749)
- WG: Hand symbol is not seen for close button while Adding drive during reconstruction of a DG.(SCGCQ01473748)
- Disabling the add PD button.(SCGCQ01488036)
- WG: no notification shown on assigning dedicated hotspare to existing DG.(SCGCQ01488155)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01509681)
- WG: Error message on a failed operation of RLM in displayed outside the allocated space.(SCGCQ01515263)
- WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01442471)
- WG: Expand windows is showing the capacity in decimal value with too many integers after decimal point..(SCGCQ01445686)
- Address Code review defects for ER SCGCQ01416373.(SCGCQ01455923)
- WG: Ambiguous "Success" message needs to be changed for disabling drive security.(SCGCQ01461177)
- Cannot import foreign configuration from LSA.(SCGCQ01524354)
- WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space.(SCGCQ01563343)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSABug.(SCGCQ01599526)

EnhancementRequests (20)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
-.(SCGCQ01404233)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461207)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- LSA: Make heavy operation by wrapping scheduler call.(SCGCQ01416373)
 - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443721)
- LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443731)
- Support drive Select ALL functionality in LSA GUI PD Operations and Mixing of drives during vd creation.(SCGCQ01454110)
- SCGCQ01454353: Retrieve and process the ESXi events in a single shot.(SCGCQ01454353)
-.(SCGCQ01454367)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- We will be removing the confirmation popup from all the actions as we got here from multiple forms like this pop up is annoying.(SCGCQ01447015)
- Support drive Select ALL functionality in LSA GUI VD/DG Operations.(SCGCQ01453114)
-.(SCGCQ01472631)

CSETActivities (87)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411631 port of SCGCQ01397546)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01420224 port of SCGCQ01419325)
- LSA service is not working in Linux.(SCGCQ01443712 port of SCGCQ01442733)
- WG: Event Log table headers needs space - Cosmetic..(SCGCQ01464556 port of SCGCQ01460053)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01466763 port of SCGCQ01424621)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Updated PD firmware version is not reflecting even after LSA refresh..(SCGCQ01501204 port of SCGCQ01382013)
- Cisco_Plumus_LR :Proper spacing should be there in between Event and History in view event logs "EventHistory not generated"..(SCGCQ01502201 port of SCGCQ01385344)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure.(SCGCQ01503907 port of SCGCQ01315392)
because of which the issue.(SCGCQ01503926 port of SCGCQ01288032)
- fixed: clear drive should not be candidate drive for create configuration.(SCGCQ01503958 port of SCGCQ01196088)
- Fixed: Span order is in reverse compare to other apps.(SCGCQ01504234 port of SCGCQ01330269)
- LSA shows max pd for Raid 1 without checking support of Raid 1E.(SCGCQ01514472 port of SCGCQ01513338)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531154 port of SCGCQ01521114)
- Making rebuild drive offline lsa gets 404..(SCGCQ01564627 port of SCGCQ01542412)
- LSA Crashes after clicking on foreign configuration.(SCGCQ01564739 port of SCGCQ01545262)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565025 port of SCGCQ01504080)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01565116 port of SCGCQ01555955)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621 )
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01599402 port of SCGCQ01563340)
- MR7.6_LSA: No Foriegn configuration details is shown in LSA.(SCGCQ01605344 port of SCGCQ01581943)
- fixed: logout causing unexpected behavior during end cim connection for vmware systems.(SCGCQ01609343 port of SCGCQ01578248)
- SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page..(SCGCQ01614982 port of SCGCQ01355833)
- LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group..(SCGCQ01617930 port of SCGCQ01401460)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01620406 port of SCGCQ01506090)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01634072 port of SCGCQ01473733)
- Raid 1 Volume creation using 4 drives is displayed as Raid 1E.(SCGCQ01686231 port of SCGCQ01686106)
- Cannot use Special Characters in Domain Name for LSA Login.(SCGCQ01747012 port of SCGCQ01745768)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected..(SCGCQ01448948 port of SCGCQ01442107)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01460039 port of SCGCQ01451571)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts..(SCGCQ01465657 port of SCGCQ00903348)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01466743 port of SCGCQ01451571)
- LSA server giving null for enclosure serial number.(SCGCQ01466744 port of )
- Address Code review defects for ER SCGCQ01416373.( port of SCGCQ01445713)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01484107 port of SCGCQ01482320)
- Added fwflash status as part of controller health status.(SCGCQ01503830 port of SCGCQ01375153)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure because of which the issue.(SCGCQ01503955 port of SCGCQ01288032)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01514258 port of SCGCQ01506045)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01514469 port of SCGCQ01507989)
- Allows raid 1e input even if RAID 1E is not supported by fw.(SCGCQ01514756 port of SCGCQ01513331)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01564633 port of SCGCQ01562368)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- WG: LSA service crashes on trying to login with URI having incorrect mac address of the server.(SCGCQ01615042 port of SCGCQ01601386)
- MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01685343 port of SCGCQ01641760)
-.(SCGCQ01685548 port of SCGCQ01685009)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687173 port of SCGCQ01686105)
- LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716641 port of SCGCQ01716622)
- SDS/HBA progress issues.(SCGCQ01460070 port of SCGCQ01052983)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01460084 port of SCGCQ01435908)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461211 port of SCGCQ01461207)
- C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01501225 port of SCGCQ01321211)
- Cisco - CSCve68492 - Storage Logs display a blank event when a secure PD is unlocked.(SCGCQ01503902 port of SCGCQ01359128)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01514773 port of SCGCQ01509259)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01526363 port of SCGCQ01509681)
- SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message.(SCGCQ01564682 port of SCGCQ01547992)
- LSA: Warning Message needs to be changed when there is Controller firmware update failure.(SCGCQ01604992 port of SCGCQ01564526)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSA.(SCGCQ01633836 port of SCGCQ01599526)
- Secure Jbod unlock is not showing the proper error message in LSA.(SCGCQ01680728 port of SCGCQ01677101)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687172 port of SCGCQ01686080)
- Cisco - CSCvi84075 - LSA, CTRL-R and HII doesn't display the foreign config when MAX VDs are present.(SCGCQ01718980 port of SCGCQ01698211)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460090 port of SCGCQ01460076)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460400 port of SCGCQ01448976)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01481410 port of SCGCQ01474461)
- LSA build script automation for VBAS environment.(SCGCQ01497385 port of SCGCQ01385344)
- Activity to check-in version files in common.(SCGCQ01520315 port of SCGCQ01512599)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- LSA Client 7.6: SPAN drives order is not maintained.(SCGCQ01614833 port of SCGCQ01539355)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline..(SCGCQ01443689 port of SCGCQ01442554)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux..(SCGCQ01480902 port of SCGCQ01479375)
- LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs..(SCGCQ01564943 port of SCGCQ01534444)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565119 port of SCGCQ01504080)
- Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time.(SCGCQ01676612 port of SCGCQ01670094)
- LSA Wont display foreign data when enclosure information in not populated properly.(SCGCQ01686054 port of SCGCQ01685449)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
-.(SCGCQ01564591 port of SCGCQ01515389)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01460393 port of SCGCQ01436886)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive..(SCGCQ01564629 port of SCGCQ01550970)
- LSA WG Fury IT: Controller type is showing as IR for IT card.(SCGCQ01564631 port of SCGCQ01540821)
- I/Os are not recover after drives pull for DHSP to rebuild..(SCGCQ01564737 port of SCGCQ01514206)

4.011.000.000 - Moderate Impact
-------------
Defects (234)
- SDS/HBA progress issues.(SCGCQ01052983)
- Fixed: Added relevant null pointer checks.(SCGCQ01319978)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01321474)
- Start PatrolRead success dialog box needs change in alignment.(SCGCQ01324866)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01325783)
- Link speed is not displaying any details in LSA.(SCGCQ01326129)
- Defect to check in code review defects.(SCGCQ01329391)
- Client js file changes for 7.3.(SCGCQ01331593)
- On Successful Firmware flash client displays improper Icon Message.(SCGCQ01332708)
- Control panel of LSA Help & support link still has reference to LSI. should be changed to broacom.(SCGCQ01337321)
- LSA asks for user permission to navigate away on clicking home button after creating simple configuration.(SCGCQ01338009)
- WG: GUI Issues pertaining to FW flash ER implementation SCGCQ01273627: Request to improve message displayed during FW Update.(SCGCQ01342542)
- IR Card global hot spare assignment is not refreshing the page.(SCGCQ01345357)
- Cisco_HSW_Validation_LSA: LSA accepting decimal values for "Set Adjustable Task Rate" which is saved as round value.(SCGCQ01345553)
- LSA 7.3 Client Coverity fix.(SCGCQ01347309)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01350435)
- WG:descripancies in update firmware page after selecting load bios option.(SCGCQ01350865)
- SCGCQ01350908: WG:Temperature of Unconfigured Drive is displayed as 0C under More properties.(SCGCQ01350908)
- WG:LSA displays Redhat icon in remote discovery page ,though SUSE is installed in system.(SCGCQ01351455)
- LSA taking the max VD size value when the user presses ENTER after specifying the VD size.(SCGCQ01356216)
- SCGCQ01356217: WG: LSA Service crashes on trying the PD details of the simple config created.(SCGCQ01356217)
- LSA_MR_7.3_Alpha: Save option can be grayed out or disabled after user saves the changes for schedule CC.(SCGCQ01357152)
- LSA_MR_7.3_Alpha: LSA doesn't display consistent Foreign Configuration information to the user.(SCGCQ01358048)
- WG: Incorrect notification shown after selecting 32 virtual drives.(SCGCQ01358095)
- SCGCQ01358097: LSA_MR_7.3_Alpha: Space optimization between the size value & size unit is needed in foreign configuration page.(SCGCQ01358097)
- LSA_MR_7.3_Alpha: User cannot select "Advanced Configuration" by clicking on the description below it in Server landing page.(SCGCQ01358122)
- LSA_MR_7.3_Alpha: Space Alignment for better presentation needed in Server Profile Page.(SCGCQ01358148)
- LSA_MR_7.3_Alpha: Percentage value for the Background Operations is not seen if browser is zoomed.(SCGCQ01358261)
- LSA crash when service starts with empty LSA.conf file.(SCGCQ01358264)
- SCGCQ01358892: Buttons "Try Updating Again" is not highlighted when user attempts to flash the firmware after any failure.(SCGCQ01358892)
- SCGCQ01358947: WG: Invalid text Content displayed on selecting multiple Virtual drives/Physical Drives.(SCGCQ01358947)
- WG: "Select Personality" dropdown lists the current personality first by default.(SCGCQ01359030)
- WG: Clickable "hand icon' is not displayed when we move cursor over Bus dev text of controller in Server summary page.(SCGCQ01359034)
- SCGCQ01372670: When User tries to click on Update FW Button, LSA asks for Navigation Confirmation without displaying Update FW page for IT.(SCGCQ01372670)
- "Add CacheCade-SSD VD" tab getting greyed out after deleting created vd,even if physical drive is selected under "Add SSD pd".(SCGCQ01372722)
- WG: VD creation fails when multiple VD's are created with 1MB size.(SCGCQ01373500)
- "Finish" button in Modify drive group work even if its grayed out.(SCGCQ01374945)
- WG: Issues pertaining to Controller Diagnostic logs.(SCGCQ01375839)
- WG: GUI Issues pertaining to Instant secure erase of an FDE Drive.(SCGCQ01375858)
- There is a mismatch about Backplane (Enclosure) "Product ID" and "Enclosure Model" in LSA.(SCGCQ01376005)
- Spare URI does not respond on iMR Invader.(SCGCQ01376605)
- WG: After physically removing the PD from the R10 DG, the DG Span tab does not load.(SCGCQ01376781)
- "Since Log Clear" does not create the last event "Log Clear" in Var/log/messages.(SCGCQ01376849)
- WG: LSA does not list the Drive Group Tab , on creation of 240 VD (15 DG, 16 VD in each of DG) and reinstalling the LSA.(SCGCQ01378585)
- WG: Windows Application Event viewer lists 31 events instead of 30, after installing LSA with the option "Since Last reboot".(SCGCQ01378669)
- WG: LSA does not automatically refresh on hiding an Degraded DG.(SCGCQ01378693)
- Client: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01378778)
- Client: WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01378782)
- WG: unable to start VD initialization on 32 VD's when there are 240 VD created & Foreign configuration present in system.(SCGCQ01378808)
-.(SCGCQ01378812)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01379795)
- WG:In premium features Safe ID & Serial Number needs to be highlited for better understanding.(SCGCQ01379818)
- WG: Close button can be given with a "hand" symbol in Compare and select form like all close button in other form has.(SCGCQ01380587)
- WG: Available Unconfigured drives is not formatted properly for display.(SCGCQ01380591)
- WG: Domain Authentication is shown as Default in "MAnage Server Page".(SCGCQ01380642)
- Size increment button is not working while modifying a VD that is created in MB size.(SCGCQ01380830)
- WG: "Advanced and Simple Configuration" is enabled when UG drives are "prepared for removal" and no other drives are left.(SCGCQ01380977)
- SCGCQ01383828: LSA service crashes while trying to access the IR3 controller.(SCGCQ01383828)
- WG:VD properties were not well partitioned for CacheCade - SSD config , compare to normal VD creation in HDD.(SCGCQ01384561)
- WG: Few enhancements needed in VD Expand form.(SCGCQ01389165)
- SCGCQ01389195: WG: Naming convention for VD can be made consistent for the VD's created through Advanced and Simple configuration.(SCGCQ01389195)
- Enter key is functioning as a backspace in "Set Adjustable Task Rate" - Can be disabled.(SCGCQ01389203)
- LSA mail server settings does not allow to enter name of smtp server.(SCGCQ01389204)
- WG: No. of VD's available to create is not shown properly for spanned vd's when span depth is modified.(SCGCQ01389421)
- Storcli: Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01392000)
- WG: More Actions for drive is not working after staring and stopping Clear operation under Drives tab.(SCGCQ01392056)
- WG: User has to click twice on the table header to change the sorting order for any table in LSA.(SCGCQ01393336)
- Copyright link is taking to top of the page rather taking to Broadcom website.(SCGCQ01393706)
- WG: PD state info is not updated properly in the Drives tab after PD's are converted from online to offline.(SCGCQ01393771)
- WG: "Clear" and "Rescan" buttons could be highlighted for the better look in Foreign Configuration Tab.(SCGCQ01394954)
- "Add Virtual Drives" is grayed out for specific VD sizes after user presses "tab-alt" keys.(SCGCQ01398966)
- WG: Verify and Sign In Buttons are overlapping in list view in Manage Server Page.(SCGCQ01399610)
- LSA is not showing "Activate..." button for Premium Features when it is navigated after "Update Firmware" page.(SCGCQ01399670)
- WG:LSA sending email alert notifications to user which doesn't exist.(SCGCQ01418580)
- Drives under both Physical drives and Span drives tab are allowed to select simultaneously.(SCGCQ01428129)
- Login to VMware is taking at time more than 30 seconds.(SCGCQ01429431)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01435908)
- WG:while editing a created VD, user cannot increase the VD size in MB .Only can decrease the size.(SCGCQ01438268)
- WG:LSA is not sorting properly the drives with different capacity of units i.e TB and GB.(SCGCQ01439751)
- WG: View server profile does not contain info on the Device id, which is sorted according to device id itself.(SCGCQ01440773)
- WG: operation of Combining JBOD drives with & without files system to move to Unconfigurued good is partially successful.(SCGCQ01440778)
- WG: Space required between two strings in the description of "Enable Drive Security".(SCGCQ01442479)
- WG: LSA Displays "Error Code:1:An user is already Logged in with Different Credentials" even user is using same credentials.(SCGCQ01442773)
- WG: LSA is changing to latest login user account though it is already logged with different User Account in different Tab.(SCGCQ01442774)
- WG: No. of UG drives are improperly updated in the Drives header tab when replace operation is triggered on a physical drive.(SCGCQ01444724)
- WG: No. Of Power Supplies info displayed is overlapping on the enclosure details. Need proper display alignment.(SCGCQ01444794)
- LSA showing 'binaryPath:./LSA' during service start in Linux.(SCGCQ01445709)
- LSA server giving null for enclosure serial number.(SCGCQ01445713)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01445719)
- WG: Description for event Code"579" is '0" in LSA event logs.(SCGCQ01446803)
- WG:"Disable Data Protection" is not updating in LSA until user do a manual refresh.(SCGCQ01447843)
- SCGCQ01448707: WG: LSA Event logs has enquiry info for Vendor, model and serial numbers appended with $ symbols.(SCGCQ01448707)
- WG: Inconsistency seen w.r.t making drive online while RLM is in progress.(SCGCQ01449722)
- WG: Event log page is navigating to change personality when the behavior mode is set from other tab of the same browser.(SCGCQ01450719)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG:Controller health status not updated on moving JBOD drive from offline --> online, personality : JBOD.()
- LSA Server: Handling of additional events in Cache module.(SCGCQ01451573)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01464514)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Enclosure ID is shown "Unknown" for NVMe JBOD only in event logs, Profile id=11.(SCGCQ01291162)
- WG: LSA page does not refresh on starting Full initialization on 240 VD.(SCGCQ01292183)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- 7.3 Client : Coverity defects check-in.(SCGCQ01308624)
- SCGCQ01309034: Coverity defect fixes check-in.(SCGCQ01309034)
- Fixed: Code maintainability issue.(SCGCQ01318344)
- coverity defect fies for : Suspicious use of non-short-circuit boolean operaton.(SCGCQ01320079)
- In Simple Config, if user select a VD and select the check box of "Assign HSP", VD size is getting changed to different size.(SCGCQ01321225)
- WG: LSA notifies user that VD will be deleted after VD erase even if the option was not selected.(SCGCQ01325795)
- WG: user notification appearing after user starts/stops the initialization on multiple VD's needs to be updated.(SCGCQ01326134)
- LSA doesn't show FW component name while FW flash operation.(SCGCQ01337028)
- WG: Multiple options of RLM are selected together for radio button used to select one of the 3 RLM operations.(SCGCQ01342615)
- LSA does not display "Link Speed" for phy 8 properly for iMR Ventura.(SCGCQ01355929)
- When the CC is scheduled as "Continuously", it is not reflected in UI after saving the changes.(SCGCQ01357007)
- Warning message has to be corrected in Foreign configuration page and one more hyperlink issue.(SCGCQ01358066)
- LSA is not taking "dot(.)" from num pad , but taking "dot(.)" form keypad while specifying the vd capacity.(SCGCQ01358908)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01364736)
- WG: LSA displays the notification "This operation can be performed only on 32 drives at a time" 32 times.(SCGCQ01373067)
- WG: Global hotspare & Dedicated hotspare are displayed as plural entities for every hotspare listed in physical drive tab.(SCGCQ01375707)
- WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01375778)
- fixed: Min & Max of "PdRaidLevel_1E" under the "pdsForRaidLevels" is populated even though it is not supported in iMR.(SCGCQ01375817)
- WG: Other hardware tab lists wrong count of list of hardware connected when enclosure connected in multipath.(SCGCQ01376109)
- WG: View server profile contents exceed the border limits of the LSA page.(SCGCQ01378556)
- SCGCQ01378774: WG: Information of the virtual drive info and PD's involved in DG vanishes on removing & inserting the PD back from a DG.(SCGCQ01378774)
- WG: Links present in Backplane properties are so light that they look like grayed out. Needs enhancement.(SCGCQ01380680)
- WG: User is allowed to click on "Next" button even if page is not completely updated during the VD creation & RLM operations.(SCGCQ01381734)
- GUI Issues found in Advanced Configuration page.(SCGCQ01381764)
- Firmware flash message should have "new" removed from string.(SCGCQ01382062)
- LSA getting logged in , even if the password is wrong.(SCGCQ01388957)
- "%" is allowed for entering no. of seconds for locating the drives.(SCGCQ01389182)
- WG: Size limit warning is thrown if the user is giving valid size using spinner button while modifying VD.(SCGCQ01389340)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01389483)
- Spinner Button for increase and decrease size is not working when the size is 1.09 TB.(SCGCQ01392053)
- WG: "Username" has to be grayed out when user start typing in the login page of "Manage Server Page".(SCGCQ01393764)
- WG: UG Drives count is not updated properly after modifying a DG.(SCGCQ01393774)
- Phase 5 IT LSA - EFI-BSD version is not displayed fully when Version length is more than 12 characters.(SCGCQ01394914)
- Mismatch in enclosure properties between LSA and storecli utility.(SCGCQ01395021)
- WG: "Managing SAS Storage Link Speed" opens up on clicking help topic of "Manage PCIe Storage Interface".(SCGCQ01395075)
- when clicking on more actions for any UG drives to make DHS,the options remains as it is in LSA though the operation is done.(SCGCQ01403884)
- WG: Like "Flash Firmware" button in "Update Firmware" page, "Update" button should also have hand symbol & one more issue.(SCGCQ01405822)
- WG: while expanding exiting VD, the expand VD page is not consistent.(SCGCQ01416379)
- Fixed: WG: LSA conf does not contain the perf mode settings options configurable.(SCGCQ01422214)
- WG: Clicking on "Benefits of each MegaRAID Advanced Software Option" in premium feature is not taking to proper link.(SCGCQ01428156)
-.(SCGCQ01428383)
- LSA doesn't allow creating spanned Raid levels with 2 spans using more than 32 drives.(SCGCQ01435647)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01436886)
- WG : "Replace Drive "window needs improvement to look uniform.(SCGCQ01439805)
- when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01440772)
- WG: LSA displays the property Drive Security Capable as 'No' even when security is supported.(SCGCQ01442209)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01443879)
- WG: Confirmation Message has to be changed when more than one drives are converted from JBOD to UG state.(SCGCQ01444672)
- SCGCQ01445818: MR 7.4_Alpha_LSA does not find a server in RHEL 7.4.(SCGCQ01445818)
- WG: LSA times out after "Clear Configuration" command is issued when there is a OFFLINE DG present.(SCGCQ01447788)
- WG: Size for the VD is not updated properly when edited during VD creation.(SCGCQ01447791)
- WG: An extra "." needs to be removed in the event description for "Initialization complete on VD".(SCGCQ01449783)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- WG: Raid 50 Vd Creation fails on unselecting drives after changing span during VD creation.(SCGCQ01309542)
- Coverity Defects - Performance Inefficiencies.(SCGCQ01313878)
- Fixed: Coverity: Class hierarchy inconsistencies.(SCGCQ01318333)
- Client: Coverty defect fixes check-in.(SCGCQ01318336)
- VD size getting increased while creating VD using simple config - Regression.(SCGCQ01341947)
- WG: Once the FW update is completed LSA shows junk character in the notification about firmware flash was successful.(SCGCQ01342536)
- SCGCQ01348082: LSA: Loopback occurs during launch. (intermittent issue).(SCGCQ01348082)
- Expand page is not closed when opened for second time.(SCGCQ01357224)
- "Add Virtual Drives" is disabled when user changes from invalid size to valid size through increment button.(SCGCQ01358299)
- WG: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01375255)
- "Server Profile" displays blank back plane info for ctrl-1.(SCGCQ01375992)
- LSA Client : Foreign Configuration Panel issues with locked and unlocked foreign drives.(SCGCQ01378050)
- DG Actions menu is not shown properly after zooming in when VD's are hidden.(SCGCQ01380663)
- WG: Size range warning is not shown while modifying VD when unit is selected from MB to GB.(SCGCQ01380818)
- LSA Evevnt: Access policy for HIDDEN/Transport is coming as Empty.(SCGCQ01380828)
- LSA Server: User is provided with Hide and Un-Hide option though there is no HIDE performed on a VD.(SCGCQ01380845)
- WG: LSA service crashes on hiding and unhiding DG's with dedicated hotspare.(SCGCQ01380912)
- SCGCQ01383765: Resolve linux server compilation issues.(SCGCQ01383765)
- WG: Reconstruction progress is not refreshed even after the VD is cleared on which reconstruction was happening.(SCGCQ01383800)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01389392)
- WG: Clicking on View server profile just before controller console page loads results in blank page.(SCGCQ01396731)
- WG: "DG degraded notification" is not auto-refreshed after Raid5 VD is brought from offline to online.(SCGCQ01398964)
- WG: When LSA is configured with NAT server, it is shown twice in the Remote Discovery Page.(SCGCQ01401484)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01401546)
- WG: Hidden links present in premium features page.(SCGCQ01412883)
- WG:VD properties details need some changes to look uniform across the application.(SCGCQ01418574)
- WG: Help link for Premium Features is opening in dual tabs.(SCGCQ01428169)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected.(SCGCQ01442107)
- WG:LSA is not showing the options "Pause Patrol Read|Abort Patrol Read" when PR background operation is running.(SCGCQ01442350)
- WG:when user is closing the message box for "Clear Configuration",the "X" symbol is not shown with hand symbol.(SCGCQ01442356)
- LSA service is not working in Linux.(SCGCQ01442733)
- WG: Invalid text"Each_Frehole" present in Pop up of Adding VD to existing Drive group.(SCGCQ01446454)
- WG: "Add Hot Spare" Button is enabled after selecting and deselecting the drives.(SCGCQ01448882)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01448976)
- WG: Event with ID 552 is not updated properly. Information on Mode is empty.(SCGCQ01450725)
- LSA Client: SDS/HBA progress issue.(SCGCQ01459948)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- LSA not giving the Un Hide All Virtual Drives operation when DG contain Hidden and normal VDs.(SCGCQ01308440)
- Coverity Defects fixes for Stream LSA7.3.(SCGCQ01311864)
- LSA7.3: Coverity defect fixes in Server code.(SCGCQ01316168)
- Coverity: Integer handling issues.(SCGCQ01318418)
- LSA Client : IR/IT Multiple Options are allowed in Update Firmware Screen.(SCGCQ01343645)
- Add hot spare page cosmetic issues.(SCGCQ01358219)
- WG:Change button is active even if button appears inactive for "Change personality", fails with an inappropriate notification.(SCGCQ01358967)
- FW last modified time is not coming properly while FW upload.(SCGCQ01359056)
- WG:while editing created vd for CacheCade - SSD Caching Configuration,the write policy tab is coming down.(SCGCQ01380641)
- WG: In "Advanced Configuration" page, Raid settings and Drive Attributes are not numbered properly.(SCGCQ01380646)
- WG: Issues pertaining to "Server is taking long to respond" LSA page.(SCGCQ01383122)
- SCGCQ01395189: WG: "Manage PCIe Storage Interface" displays empty table for MR Ventura controller with profile id 13.(SCGCQ01395189)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01415223)
- WG: Question mark missing in "Erase" confirmation form.(SCGCQ01415923)
- WG: Extra "." (dot) has to be removed in VD Initialization confirmation message and one more cosmetic issue.(SCGCQ01428137)
- WG: Instance Validation is failing for driveGroupConfigurationService-schema.json in MR_Ventura card.(SCGCQ01443739)
- MR7.4_Alpha_LSA crashed when trying to download firmware RHEL 7.4.(SCGCQ01447240)
- LSA Client Refresh issue while making more than one drive(s) offline when RLM is in progress.(SCGCQ01449870)
- WG: No success /failure Notification is shown in server summary page on making a offline drive online.(SCGCQ01451575)
- WG:2 Spans(Modify Span Depth) is showing in "Advance configuraton" page even if their is no PD left for the config.(SCGCQ01452129)
- WG:when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01464425)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01479375)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ00903348)
- LSA should not allow to select the check box of VD and PD simultaneously on xSDS-None mode.(SCGCQ01323724)
- Issue : Instant Secure erase option is seen when FDE and NON-FDE drives are selected.(SCGCQ01326164)
- SCGCQ01332799: Resolve LSA server compilation issue.(SCGCQ01332799)
- LSA conf file not being updated While changing the default port 2463 and 9000 to some other free ports in windows_8.1_x64.(SCGCQ01375895)
- WG: "?" symbol is in the centre of the Drive erase page unlike in other pages.(SCGCQ01383763)
- WG: ESXi server name is not completely visible in Manage Servers page.(SCGCQ01389332)
- WG: UI Enhancement: Hand symbol has to be given for the "Modify VD" icon for better user experience.(SCGCQ01389343)
- Foreign Configuration issues locked and unlocked foreign drives count.(SCGCQ01391010)
- Action successful message needs to be modified for better User experience.(SCGCQ01392057)
- spandepth need one space between span & depth, to look uniform across the application.(SCGCQ01413225)
- Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01423352)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01460076)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01394281)
- WG: Help link for "Activate Features" after providing the Activation key is not working.(SCGCQ01398969)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01424621)
- Added the "?" at the end of instant secure erase. But there no issue related line in more actions panel please find the attached screenshot.(SCGCQ01442352)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01474461)
- 'X' symbol for removing physical drives are not highlighted when the drives are allowed to be removed.(SCGCQ01350436)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)

EnhancementRequests:
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- SLIR3: Change build scripts and makefiles to account for change in directory structure and new name of the library.(SCGCQ00293713)
-.(SCGCQ01389581)
- LSA Page tab name should be changed.(SCGCQ01401514)
-.(SCGCQ01416369)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444590)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- SLIR3: Remove Libsysfs dependency in StoreLibIR3.(SCGCQ00293709)
- Adding Solaris and Sparc X64 bit support in SLIR3.(SCGCQ00922699)
- Change library name to SLIT.(SCGCQ00933175)
-.(SCGCQ01309820)
- LSA Server : [Lenovo Purley] Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01352474)
- HBA nvdata version in Decimal Format in LSA.(SCGCQ01365643)
- WG: Dedicated Hot spare Notification pop-up alignments.(SCGCQ01401505)
- Schedule API changes for time consuming APIs.(SCGCQ01422386)
- MR7.4: Support for FW ER:SCGCQ01389581 in LSA Server.(SCGCQ01428115)
- Update the WebServer Nginx to fix the latest Security Vulnerabilities.(SCGCQ01452493)
- SAS3 Ph8 --- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00729472)
- LSA Client: Handle Progress events without initiating individual API calls.(SCGCQ01416371)
- LSA: Make operation call with query parameter.(SCGCQ01424479)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- WG: Landing page - Graphics improvements.(SCGCQ01401517)
-.(SCGCQ01412749)
- Support for FW ER:SCGCQ01389581 in LSA Client.(SCGCQ01428113)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- LSA7.3: LSA to hide the Empty back plane based on the property field in the LSA.conf file.(SCGCQ01312022)
- LSA: Make operation call with query parameter.(SCGCQ01416374)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- SCGCQ01250909 - [Lenovo Purley] - Retrieve Boot Events and Maintain it as part of Event History.(SCGCQ01291488)
- Client: EPMR12 porting to MR7.3.(SCGCQ01304973)
- Client: Provide pending profile details in LSA.(SCGCQ01331947)
- LSA Server: EPMR12 defect/feature porting to MR7.3.(SCGCQ01307382)
-.(SCGCQ01356193)
-.(SCGCQ01375857)
- WG: In Remote discovery page Self server is always listed in the last.(SCGCQ01378666)
-.(SCGCQ01472631)

CSETActivities:
- VMware LSI Out of Box driver feature reconciliation.(SCGCQ00696009 port of SCGCQ00652798)
- Provide a StoreLibIR2 deb package to work on Ubuntu.(SCGCQ00795333 port of SCGCQ00630108)
- WG: No Units are displayed for Event ID: 545: Information about super cap health.(SCGCQ01297685 port of SCGCQ01291338)
- LSA throws inappropriate error while attempt to start controller firmware upgrade when pinned cache present on controller.(SCGCQ01297819 port of SCGCQ01288364)
- CSCvd88927 - LSA is displaying drives' type string inconsistently for HDD/SSD so it needs to display consistently.(SCGCQ01331599 port of SCGCQ01316465)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336569 port of SCGCQ01313804)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337104 port of SCGCQ01332737)
- Hercules LSA : Schedule CC button does not allow to click on the whole button.(SCGCQ01339214 port of SCGCQ01337027 )
- PR on all drives are not aborted properly until page refresh is done.(SCGCQ01342568 port of SCGCQ01340808)
- No. of steps shown in "Modify Drive Group" page is not correct.(SCGCQ01343651 port of SCGCQ01341921)
-.(SCGCQ01345364 port of SCGCQ01342479)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01345398 port of SCGCQ01332912)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347171 port of SCGCQ01346904)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347220 port of SCGCQ01346908)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347221 port of SCGCQ01346908)
- Cisco_HSW_Validation_LSA: "Simple Configuration" page that appears after creating a simple config is blank.(SCGCQ01347224 port of SCGCQ01345554)
- Cisco_HSW_Validation_LSA: Character limit warning for VD name is not shown while modifying the VD during VD creation.(SCGCQ01347232 port of SCGCQ01345557)
- Cisco_HSW_Validation_LSA: VD Size limit check is not working when user modifies the value of the size.(SCGCQ01350834 port of SCGCQ01346906)
- Cisco_HSW_Validation_LSA: Prepare for removal menu is still displayed even after the option is selected and event is updated.(SCGCQ01350837 port of SCGCQ01338290)
- "%" symbol followed by integer value should not be allowed for the user to enter the size during VD creation.(SCGCQ01350844 port of CGCQ01349556)
- Page scroll doesn't work after VD creation when BG processes on VD are expanded in LSA page.(SCGCQ01351383 port of SCGCQ01349487)
- VD creation fails when a partial VD is added with decimal value & with 1MB strip size to an existing DG.(SCGCQ01354306 port of SCGCQ01348005)
- Security Key provided for importing Foreign Config is not taken by LSA.(SCGCQ01369266 port of SCGCQ01331016)
- Unexpected sense PD messages are flooded in storage log when drive is in spun dwon mode.(SCGCQ01369267 port of SCGCQ01264499)
-.(SCGCQ01375259 port of SCGCQ01373451)
- LSA: Client should not show Unlock drive option if no drives are in locked state.(SCGCQ01378557 port of SCGCQ01331121)
- LSA Server: Windows Make file check-in.(SCGCQ01384621 port of SCGCQ01384618)
- RWC3 Package: Check-in of SL-IT to the package folder.(SCGCQ01384895 port of SCGCQ01384890)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01387017 port of SCGCQ01350435)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389917 port of SCGCQ01389892)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01389918 port of SCGCQ01385340)
- HPE: Un-installation is not removing the folder(s) after performing the Download Diagnostics operation.(SCGCQ01389925 port of SCGCQ01385453)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01391318 port of SCGCQ01389483)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01419753 port of SCGCQ01417215)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ01440910 port of SCGCQ00903348)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275670 port of SCGCQ01275496)
- For phys-schema.json fails for "([0, u'properties', u'isEnabled', u'enum'], 'False ...".(SCGCQ01309844 port of SCGCQ01304900)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01323613 port of SCGCQ01284395)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324865 port of SCGCQ01260226)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01338337 port of SCGCQ01331755)
- Hercules LSA : Cachecade SSD caching should be "enabled" under controller properties.(SCGCQ01339133 port of SCGCQ01337029)
- Hercules LSA : WB and AWB description in LD create page not proper.(SCGCQ01339213 port of SCGCQ01337026)
- User couldn't enter his value in seconds for locating a physical drive.(SCGCQ01344082 port of SCGCQ01332742)
- Cisco_HSW_Validation_LSA: Tooltip for "Simple Configuration" is not shown when other options displays it.(SCGCQ01347225 port of SCGCQ01346851)
- Cisco_LSA: Hyperlink symbol can be shown for "Compare and select" link in Modify Drive Group.(SCGCQ01350847 port of SCGCQ01348107)
- Cisco_HSW_Validation_LSA: Naming convention can be made same across all "Virtual Drive Erase" forms.(SCGCQ01350850 port of SCGCQ01347250)
- cosmetic changes required in "Advanced configuration" page.(SCGCQ01350851 port of SCGCQ01347253)
- DG health is not populated properly in cisco cards.(SCGCQ01350892 port of SCGCQ01349625)
- Virtual Drive Erase form is not closed when it is opened for the second time.(SCGCQ01351381 port of SCGCQ01347243)
- While adding drives to any raid group, Displaying no. of available drives and selected drives can be fine tuned.(SCGCQ01351385 port of SCGCQ01348115)
- Cisco_LSA: "Background Initialization" is misspelled in Event description & one more cosmetic change is required.(SCGCQ01351454 port of SCGCQ01348041)
- In case of FW upload, LSA crash seen with big FW version name.(SCGCQ01351457 port of SCGCQ01338340)
- LSA Client: During the exclusion of the VDs from deletion of one VD leading to the deletion of all the VDs.(SCGCQ01354432 port of SCGCQ01344115)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01387009 port of SCGCQ01379795)
- Hercules:LSA:Observe that instead of "Feedback " it is named as "FeedBack ".(SCGCQ01389091 port of SCGCQ01388943)
- Updated PD firmware version is not reflecting even after LSA refresh.(SCGCQ01392422 port of SCGCQ01382013)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01393239 port of SCGCQ01385340)
- Hercules LSA: "Prepare for removal" feature should be disabled for drives in LSA.(SCGCQ01401490 port of SCGCQ01396735)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- Updating readme file.(SCGCQ01294583 port of SCGCQ01294570)
- For spares-schema instance validation failed for "u'foreign' is not one of [u'NATIVE', u'FOREIGN', u'MIXED']".(SCGCQ01311504 port of SCGCQ01309617)
- LSA server:LSA not showing the server reboot message after profile set.(SCGCQ01316473 port of SCGCQ01316342)
- HSW_testing_LSA : Could not initialize a VD after disabling and enabling again "Initialize" option.(SCGCQ01321339 port of SCGCQ01309783)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337071 port of SCGCQ01332737)
- Cisco_HSW_Validation_LSA: Size range warning is not shown when user is giving value beyond the limit in MB unit.(SCGCQ01352603 port of SCGCQ01352603)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01369283 port of SCGCQ01284395)
- RWC3 Automation Script files check-in.(SCGCQ01385008 port of SCGCQ01384997)
- LSA/RWC Automation batch files check-in.(SCGCQ01386218 port of SCGCQ01386214)
- Hercules:LSA: trying to open in new tab : "Copyright @ 2017 by Avago Technologies. All Rights Reserved" loads blank page.(SCGCQ01389089 port of SCGCQ01386140)
- Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01389588 port of SCGCQ01352480)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01392429 port of SCGCQ01385340)
-.(SCGCQ01392506 port of SCGCQ01391775)
- [Lenovo 17B] - LSA- Selected Firmware version doesn't match while upgrading the FW.(SCGCQ01420040 port of SCGCQ01417199)
- Hercules:LSA: Multiple OLH links are opening when clicked on Advance configuration( IE Browser).(SCGCQ01429992 port of SCGCQ01415979)
- LSA Linux BST Automation scripts.(SCGCQ01466009 port of SCGCQ01447013)
- operations-schema.json fails for "u'percentage' is a required property..." in xSDS mode.(SCGCQ01297806 port of SCGCQ01291332)
- Hercules LSA : Auto refresh not happening on Enclosure push pull with 64 VD's configured.(SCGCQ01297821 port of SCGCQ01276760)
- SCGCQ01309545: WG: Issues pertaining to Event ID: 545: Super Cap Health event has redundant data, missing comma's.(SCGCQ01332698 port of SCGCQ01309545)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01338335 port of SCGCQ01332912)
- Cisco Validation: FW throws an exception while scheduling Consistency check on R1.(SCGCQ01347254 port of SCGCQ01340788)
- VD size is created with improper size when user creates volume by first decreasing and increasing the size in MB unit.(SCGCQ01350833 port of SCGCQ01346860)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01395078 port of SCGCQ01394281)
- Wrong API populated for enclosures operations and schema will fail.(SCGCQ01445408 port of SCGCQ01444689)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01447743 port of SCGCQ01445719)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01458204 port of SCGCQ01443879)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336556 port of SCGCQ01313804)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347125 port of SCGCQ01346904)
- Cisco_HSW_Validation_LSA: Credentials asked during login is not proper when login mode is set to 'Domain Login'.(SCGCQ01347233 port of SCGCQ01341930)
- Hercules-LSA : Updated PD firmware version is not reflecting automatically.(SCGCQ01393283 port of SCGCQ01392496)
- Hercules:LSA: Linux RHEL 6.9: View Event Logs Icon display not proper.(SCGCQ01414738 port of SCGCQ01409445)
- Hercules LSA: Reference to "drive group" while adding logical drive to existing array.(SCGCQ01444720 port of SCGCQ01444670)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01480902 port of SCGCQ01313228)
- Fixed: Drive group Migration was disabled with NVME drives DG.(SCGCQ01313228 port of SCGCQ01289586)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324864 port of SCGCQ01260226)
- Spare URI does not respond on iMR Invader.(SCGCQ01378677 port of SCGCQ01376605)
- [PA_2017B_SDV_Lenovo_x3650 M4_Storage] LSA tool update FW Image (oss: 75871) Failed for N2225 SAS HBA(Outback-2) card.(SCGCQ01408778 port of SCGCQ01408626)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411632 port of SCGCQ01397546)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01417213 port of SCGCQ01415347)
-.(SCGCQ01417223 port of SCGCQ01375862)
- LSA: Make operation call with query parameter.(SCGCQ01423429 port of SCGCQ01416374)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01427110 port of SCGCQ01419325)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01345397 port of SCGCQ01331755)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01354345 port of SCGCQ01321474)
- Hercules LSA: Default write policy for R1 CC VD should be WB instead of WT.(SCGCQ01401352 port of SCGCQ01397557)
- [Lenovo 18A] 110340 - [PA_2017B_SDV_Lenovo_Red_Reno_Storage] Use LSA to configure M5225 and it fail to create VD's from LSA.(SCGCQ01424599 port of SCGCQ01421451)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline.(SCGCQ01443687 port of SCGCQ01442554)
- Phase 2 changes for Linux VBAS automation script.(SCGCQ01460081 port of SCGCQ01455968)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
- CSCvd28635: LSA throws inappropriate error while attempt to start patrol read on virtual drive with SSDs.(SCGCQ01319398 port of SCGCQ01284997)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01332824 port of SCGCQ01325783)
- To resolve the merge conflict.(SCGCQ01348161 port of SCGCQ01348057)
- Port Info disappears on doing Drive push pull.(SCGCQ01404636 port of SCGCQ01379323)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444595 port of SCGCQ01444590)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)


3.023.000.000 - Moderate Impact
-------------


2.090.000.000 - Moderate Impact
-------------
Enhancement:
- Added Support for ThinkSystem HBA and RAID adapters


2.085.000.000 - Moderate Impact
-------------
- Fixed issue where logs incorrect when remove/insert hdd (SCGCQ01246085)
- Fixed Invalid Server Id as part of event, if server is not in network (SCGCQ01261779)
- Fixed issue where moving PD from slot 0 to another slot, PD slot ID usually still show slot 0 and slot format (SCGCQ01264554)
- Fixed issue where external enclosure serial number in not consistent between LSA, MSM and storcli (SCGCQ01268914)
- Fixed issue where LSA does not list Raid 10 as configurable raid level under configuration service uri when drive mixing is allowed (SCGCQ01037806)
- Fixed issue where Incorrect configurable Volume sizes displayed in LSA for Raid 0(SCGCQ01039518)
- Fixed issue where LSA is not un-installing through the Uninstall-LSA option through Windows All Programs (SCGCQ01039698)
- Fixed issue where VD Properties in LSA was not getting populated for default settings (SCGCQ01043610)
- Fixed issue where controllers/{id}/spares is not populated correctly (SCGCQ01056900)
- Fixed issue where LSA displays only 2 enclosures when four enclosures are connected. (SCGCQ01061548)
- Fixed issue where Enclosure more properties displays "Number of Voltage Sensors" as "0" (SCGCQ01063504)
- Fixed issue where On Number of Temperature Sensors observe that temperature mentioned has 65535 C. (SCGCQ01063924)
- Fixed issue where When the PD is in GHS state LSA is displaying the Prepare for removal option (SCGCQ01064282)
- Fixed issue where LSA does not display the access policy 'hidden' in View Event Logs. (SCGCQ01065622)
- Fixed issue where schedule patrol -read throws an error 'Invalid URI parameter' when user clicks on Finish button. (SCGCQ01066126)
- Fixed issue where Unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01066154)
- Fixed issue where LSA crashes while trying to add a VD to the RAID 00 drive group. (SCGCQ01069405)
- Fixed issue where Simple configuration fails while trying to create VD using SSD Drive (SCGCQ01069412)
- Fixed issue where compared with MSM values of "Date of manufacture" and "Type" is varying. (SCGCQ01069493)
- Fixed issue where Unable to clear or import partial foreign configuration from LSA. (SCGCQ01069580)
- Fixed issue where Ventura: LSA still displays clear button as active even after successfully importing foreign configuration. (SCGCQ01069616)
- Fixed issue where IR3 Events logs are listed reverse sequence in "View Event logs" (SCGCQ01069847)
- Fixed issue where LSA Drive Tab PD "Unconfigured Good" count does not automatically refresh when we Move UG PD to JBOD and vice versa(SCGCQ01069852)
- Fixed issue where Modifying the VD during the VD creation results in option for user to allow more than one cachecade VD, Creation fails (SCGCQ01069898)
- Fixed issue where Instance validation fails for Clear Drive, Stop Clear Drive, Prepare & Undo prepare for removal due to "parameters":{}" (SCGCQ01070441)
- Fixed issue where Instance validation fails for Manage Power Save Settings, Controller PUT operation (SCGCQ01070690)
- Fixed issue where Instance Validation fails for Schedule Consistency Check (SCGCQ01070739)
- Fixed issue where Instance Validation fails for Physical Devices GET (IT controller) (SCGCQ01074960)
- Fixed issue where Server not found warning message is displaying repeatedly one over the other (SCGCQ01075026)
- Fixed issue where Backplane information not displayed under view server profile (SCGCQ01075841)
- Fixed issue where if config cleared during reconfiguration, progress bar does not clear(SCGCQ01075843)
- Fixed issue where hide on DG is not automatically updating the access policy of VDs (SCGCQ01076009)
- Fixed issue where LSA Crashes when we run API performance Script ususally when performing PD Operations GET in Large config (240 PD)(SCGCQ01076023)
- Fixed issue where "Controller Info" of LSA displays driver version of the Gateway server instead of displaying the driver of Vmware server (SCGCQ01076031)
- Fixed issue where "Application Version" in server profile page is displayed as "LSA Server null". (SCGCQ01076146)
- Fixed issue where there were multiple extra columns in PD tab (SCGCQ01077452)
- Fixed issue where the Physical devices are listed in Decreasing order of Device ID instead of ascending order in drive tab (SCGCQ01077563)
- Fixed issue where firmware update does not happen in the Direct agent system from Gateway (SCGCQ01077677)
- Fixed issue where Manage Power save settings with input of " 1 hour" fails with an error " Input Parameters are Invalid" (SCGCQ01078509)
- Fixed issue where Managed Server page provides option of adding gateway server from which we have already logged in to manage server (SCGCQ01078524)
- Fixed issue where Feedback is displayed as FeedBack in LSA. (SCGCQ01079092)
- Fixed issue where After adding server in Manage Server Page intermittently get a junk screen  (SCGCQ01079698)
- Fixed issue where back button does not work in case of Advanced Configuration During VD Creation (SCGCQ01079912)
- Fixed issues pertaining to "Set Patrol Read Properties" Number of PD Count allowed for patrol read (SCGCQ01080265)
- Fixed issue where after logging out from server that is been managed. Clicking Server again in managed server page LSA asks for credentials (SCGCQ01080448)
- Fixed issue where Instance Validation fails for PROGRESS related Operations (SCGCQ01082194)
- Fixed issue where Instance validation fails for "/controllers/0/operations/security" URI : Controller Operation POST (SCGCQ01082618)
- Fixed issue where inappropriate error message is displayed in LSA on flashing fw on IT Intruder (SCGCQ01082897)
- Fixed issue where LSA page does not automatically refresh when PD moved from UG bad to UG Good SS page, CC page does not give option (SCGCQ01083060)
- Fixed issue where on clicking save button on mail server page its shift to Alert Settings without saving that page. (SCGCQ01083063)
- Fixed issue where LSA does not show the default power save mode time set in mfc (SCGCQ01083106)
- Fixed issue where after adding server the managed server list, then logging out, new server cannot be logged into. (SCGCQ01083226)
- Fixed issue where LSA service is not present in the Windows services after downgrading LSA. (SCGCQ01084774)
- Fixed issue where Event Response is giving Default Write Policy: abc (SCGCQ01043609)
- Fixed issue where Sending Invalid HTTP verb in the request for an URI fails with 404 instead of 405 (SCGCQ01059216)
- Fixed issue where texts linked to the health icons "optimal", "critical", "needs attention", in server summary page Should be clickable (SCGCQ01063432)
- Fixed issue where LSA still displays physical disk actions and properties menu when no pd is selected after sorting from Enclosure/slot. (SCGCQ01063524)
- Fixed issue where Instance Validation fails for Simple Configuration POST (SCGCQ01064737)
- Fixed issue where consistency check Schedule parameters is available even after selecting the "Disable" from the Consistency check mode (SCGCQ01069825)
- Fixed issue where LSA not accessible through Chrome browser Version 48.0.2564.109 m (SCGCQ01078618)
- Fixed issue where while initiate ISE against 3rd party locked UG drive, XHR_Header code says "POST 200" but XHR_Response says "Er 77" (SCGCQ01080402)
- Fixed inconsistency between the VD properties displayed in STORCLI when compared with other Apps. (SCGCQ01081145)
- Fixed issue where LSA doesn't get updated without a service restart on Vmware server with IR3 controller. (SCGCQ01081324)
- Fixed issue where matching error description is not shown by client when there is a session already active during login. (SCGCQ01063542)
- Fixed issue where LSA login attempt failed for Vmware Server (SCGCQ01064784)
- Fixed issue where 002.010.000.000 build (Gateway & Standalone) is unable to discover server (SCGCQ01069396)
- Fixed issue where replace drive table does not have device Id column (SCGCQ01075112)
- Fixed issue where LSA does not update the data automatically when Delete VD is performed. (SCGCQ01079635)
- Fixed issue where RWC3-LWM (Windows) is unable to send mail to SMTP (SCGCQ01173361)
- Fixed issue where Ventura IT drive push and pull needs services restart to update the count (SCGCQ01066048, Port of SCGCQ01064904)
- Fixed issue where LSA Allows JBOD Drive having OS to be converted to UG drive, doesnt notify the user on the OS present on JBOD (SCGCQ01067253, Port of SCGCQ01052412)
- Fixed issue where LSA displays "error:Not all values are set successfully" while trying to save power save settings on IMR Ventura. (SCGCQ01067711, Port of SCGCQ01057457)
- Fixed issue where LSA shows blank screen after log in with mutiple controller in the setup (SCGCQ01069360, Port of SCGCQ01068813)
- Fixed issue where intermittent update Ventura firmware hang using LSA ( StorCLI is OK ) (SCGCQ01069565, Port of SCGCQ01038421)
- Fixed issue where user unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01070807, Port of SCGCQ01066154)
- Fixed issue where all the events are not getting downloaded while downloading log from LSA (SCGCQ01145261, Port of SCGCQ01139334)
- Fixed issue where no error message is displayed while importing secure EPD through wrong key (SCGCQ01066088, Port of SCGCQ01063911)
- Fixed issue where user unable to clear or import partial foreign configuration from LSA. (SCGCQ01085466, Port of SCGCQ01069580) 

2.030.000.000 - New Function Only/No fixes
-------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

StorCLI command line tool for anyos



StorCLI (Command Line) Utility for Storage Management

Adapters Supported:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB  Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-16i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller
  - ServeRAID M5210e SAS/SATA Controller for System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5215 SAS/SATA Controller (00JX142)
  - ServeRAID M5115 SAS/SATA Controller (90Y4390)
  - ServeRAID Lenovo Storage Expansion Node (65Y8588)
  - ServeRAID M5110 SAS/SATA Controller for Lenovo System x (81Y4481)
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)

NOTE TO SERVICE - Reference RETAIN #N/A

007.0713.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) 
 - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01556595) 
 - controller show all command is not listing the Battery information(SCGCQ01561689) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) 
 - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) 
 - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) 
 - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) 
 - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) 
 - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) 
 - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) 
 - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) 
 - Spell mistake in error message for hwdev command(SCGCQ01614972) 
 - Coverity defect fix for itctflash file(SCGCQ01616369) 
 - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) 
 - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) 
 - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) 
 - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) 
 - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) 
 - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) 
 - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) 
 - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) 
 - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) 
 - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) 
 - Help content for jbodx show unmap is not present(SCGCQ01790130) 
 - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - storclio command not working to update FW on SATA disk(SCGCQ01918814) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) 
 - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) 
 - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) 
 - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) 
 - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) 
 - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) 
 - Checking in VBAS compliation changes(SCGCQ01630324) 
 - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) 
 - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) 
 - Space need in the output for secure erase(SCGCQ01713604) 
 - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) 
 - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) 
 - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) 
 - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) 
 - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) 
 - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01735493) 
 - Storcli vib update fails across releases.(SCGCQ01761795) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) 
 - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) 
 - Removing the set/show of unmap on JBOD.(SCGCQ01817855) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) 
 - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) 
 - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) 
 - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01595640) 
 - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) 
 - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) 
 - Update help contents for jbod delete(SCGCQ01624605) 
 - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) 
 - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) 
 - Missing punctuation in Perccli delete config message(SCGCQ01698226) 
 - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) 
 - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) 
 - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) 
 - Drive Fw download Coverity fixes(SCGCQ01615074) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) 
 - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) 
 - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) 
 - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) 
 - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) 
 - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) 	
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) 
 - Updating the Diag results as per new API changes(SCGCQ01537255) 
 - Resource leaks,Uninitialized variables(SCGCQ01600311) 
 - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) 
 - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) 
 - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) 
 - Removal of ncurses references for linux makefile(SCGCQ01955544) 
  - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) 
 - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) 
 - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) 
 - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) 
 - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) 
 - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) 
 - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) 
 - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) 
 - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) 
 - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) 
 - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) 
 - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) 
 - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) 
 - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) 
 - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) 
 - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) 
 - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) 
 - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) 
 - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) 
 - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) 
 - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) 
 - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) 
 - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) 
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) 
 - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) 
 - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) 
 - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) 
 - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) 
 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) 
 - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) 
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) 
 - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) 
 - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) 
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) 
 - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) 
 - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) 
 - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) 
 - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) 
 - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) 
 - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) 
 - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) 
 - .(SCGCQ01571935 port of SCGCQ01325052) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) 
 - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) 
 - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) 
 - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) 
 - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) 
 - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) 
 - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) 
 - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) 
 - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) 
 - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) 
 - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) 
 - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) 
 - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) 
 - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) 
 - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) 
 - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) 
 - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) 
 - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) 
 - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) 
 - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 
EnhancementRequests
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) 
 - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) 
 - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) 
 - Need Storcli support drive FW upgrade(SCGCQ01583217) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) 
 - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) 
 - Add a bit for atomic descriptor capable(SCGCQ01965047) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01583223) 
 - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) 
 - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) 
 - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) 
 - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) 
 - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) 
 - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 


007.0525.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects (16)
-.(SCGCQ01753405)
- Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033)
- Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315)
- Enclosure show status command gives success but nothing is shown.(SCGCQ01731280)
- One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763)
- Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927)
- Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612)
- Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548)
- Space need in the output for secure erase.(SCGCQ01713604)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Missing punctuation in Perccli delete config message.(SCGCQ01698226)
- Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265)
- non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272)
- DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443)
- WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279)
- Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752)
- perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719)
- storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990)
- State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444)
- Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355)
- storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816)
- Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795)
- storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493)
- Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849)
- Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269)
- "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017)
- controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704)
- Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749)
- Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493)
- Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354)
- PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418)
- Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616)
- Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223)
- Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972)
- StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602)
- Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983)

EnhancementRequests (30)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730)
-.(SCGCQ01593479)
-.(SCGCQ01761309)
- displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528)
- Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603)


0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence
-------------------

Defects (75)
- Profile Mgmt API Changes.( SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- Enable WB support via API.(SCGCQ01405242)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979)
- Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940)
- storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171)
- Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396)
- Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401)
- Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745)
- Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131)
- Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420)
- Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852)
- Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910)
- Detailed help contents were not present for most of the IT download options..(SCGCQ01483760)
- Spelling errors in the "/cx restart" command..(SCGCQ01486415)
- Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052)
- CLI help does not reflect the new command to create an ePD.(SCGCQ01639583)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- Instance Validation is failing for mentioned commands..(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447)
- Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990)
- PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588)
- Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580)
- Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694)
- PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920)
- PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062)
- Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041)
- Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421)
- Checking in VBAS compliation changes.(SCGCQ01630324)
- PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798)
- Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240)
- Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214)
- MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582)
- Schema addition for "show file=" command.(SCGCQ01461209)
- PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593)
- MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562)
- PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762)
- Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845)
- Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344)
- Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670)
- OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785)
- Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797)
- Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- Incorrect help description for erase and download completeflash commands.(SCGCQ01470263)
- Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802)
- Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833)
- Check for supported pages for firing drive SCSI commands.(SCGCQ01474325)
- No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900)
- IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753)
- Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446)
- Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195)
- Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334)
- Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821)
- UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749)


EnhancementRequests (174)
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType..(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- JSON schema for Drive level commands.(SCGCQ01445435)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
-.(SCGCQ01389581)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- Removing the NMR storcli commands from storcli..(SCGCQ01445268)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
- Removing the NMR storcli commands from storcli..(SCGCQ01445418)
-.(SCGCQ01428114)
-.(SCGCQ01423509)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987)
- Add NVMe device related changes.(SCGCQ01034678)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986)
- Add boot drive selection support in Stor-CLI.(SCGCQ01445896)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424)
-.(SCGCQ01466805)
- StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954)
- StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799)
- Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308)
- Add support for IT Firmware images and IT Completeflash images to "show file=" command.(SCGCQ01436882)

CSETActivities (57)
- StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445)
- Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174)
- Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483)
- Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457)
- Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170)
- Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237)
- SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496)
- Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245)
- This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717)
- Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154)
- Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920)
- Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496)
- Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780)
- Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929)
- Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698)
- Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009)
- Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154)
- storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595)
- Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709)
- Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360)
- Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764)
- Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886)
- Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526)
- Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435)
- Updating readme file(SCGCQ01294583 port of SCGCQ01294570)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453)
- Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412)
- Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234)
- Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605)
- Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562)
- Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703)
- Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628)
- Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447)
- Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256)
- Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552)
- Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578)
- Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900)
- DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749)
- syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675)
- controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689)
- Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481)
- Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460)
- Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156)
- Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214)
- CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640)
- Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618)
- Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793)
- Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255)
- Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754)

0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------
fixes:
- Profile Mgmt API Changes.(SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846)
- Fixing Error Handling issues and Resource leak.(SCGCQ01319395)
- Fix for Libmod files having potential loop errors.(SCGCQ01320336)
- Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003)
- EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452)
- Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604)
- Updated the Help.(SCGCQ01375059)
- controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816)
- Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238)
- storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690)
- Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425)
- Fixing out of bounds in libmods.(SCGCQ01385430)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177)
- Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543)
- PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511)
- Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756)
- Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011)
- Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239)
- Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897)
- Need to handle FW return code change for profile management success case.(SCGCQ01307320)
- Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405)
- PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477)
- Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749)
- CLI reports failure when issuie DPM commands.(SCGCQ01333085)
- PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041)
- Fixing unchecked return values.(SCGCQ01385377)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610)
- Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922)
- LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583)
- Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764)
- Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948)
- Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222)
- This is a syntactical error where a comma was added.(SCGCQ01414744)
- Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208)
- Instance Validation is failing for mentioned commands.(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
- StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018)
- IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046)
- Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219)
- Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438)
- Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771)
- Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
- PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757)
- Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407)
- Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042)
- CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639)
- Removing the memory leaks in dequelog command.(SCGCQ01411544)
- Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758)
- Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934)
- Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Fixing Out of Bounds access and Resource leak.(SCGCQ01304875)
- Inconsistencies between the applications for manage link speed.(SCGCQ01389856)
- Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106)
- Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- StorCLI: Spindown help syntax is misleading.(SCGCQ01421610)
- Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
- StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900)
- Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891)
- Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748)
- Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890)
- Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943)
- Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289)
- StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557)
- Removing the NMR command for setting SCAPVPD.(SCGCQ01389451)
- Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749)

EnhancementRequests:
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType.(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
-.(SCGCQ01421997)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793)
- RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354)
- Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469)
- Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465)
- List pending profile details of the controller.(SCGCQ01346308)
-.(SCGCQ01291037)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- always print StorCLI version information at beginning/top of output.(SCGCQ01396733)
- StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177)
- New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
-.(SCGCQ01428114)
- Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646)
- Add NVMe device related changes.(SCGCQ01034678)
- Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301)
- Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079)
- Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)

CSETActivities:
- StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018)
- MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830)
- Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790)
- MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315)
- MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798)
- Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785)
- SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496)
- Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610)
- Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900)
- CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 )
- Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789)
- Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152)
- Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673)
- Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381)
- Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320)
- MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757)
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529)
- MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520)
- Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274)
- MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453)
- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843)
- Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891)
- CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 )
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177)
- Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604)
- Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843)
- Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152)
- C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830)
- Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495)
- Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145)
- Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484)
- [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914)
- Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728)
- MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756)
- MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493)

0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
 - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536)
 - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913)
 - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948)
 - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629)
 - Code clean up in libmods and sysefi files are added(SCGCQ00359998)
 - Storcli is returning error with show(SCGCQ00360040)
 - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814)
 - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216)
 - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717)
 - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455)
 - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522)
 - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097)
 - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248)
 - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622)
 - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735)
 - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000)
 - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155)
 - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735)
 - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364)
 - portings of AdpRestart command(SCGCQ00378135)
 - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828)
 - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104)
 - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303)
 - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789)
 - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832)
 - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350)
 - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610)
 - SWR_1.34(SCGCQ00442652)
 - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502)
 - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583)
 - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843)
 - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560)
 - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201)
 - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579)
 - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935)
 - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835)
 - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123)
 - Storcli : unable to set patrol read delay(SCGCQ00645195)
 - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324)
 - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742)
 - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131)
 - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171)
 - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192)
 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505)
 - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647)
 - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770)
 - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178)
 - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183)
 - Adapters are not listed in sorted order.(SCGCQ00759969)
 - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398)
 - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752)
 - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663)
 - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712)
 - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243)
 - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789)
 - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882)
 - "cpybck" help is not coming in Legends(SCGCQ00784808)
 - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400)
 - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232)
 - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374)
 - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394)
 - .(SCGCQ00800878)
 - Deallocation of the same memory more than once(SCGCQ00802031)
 - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588)
 - Out-of-bounds access and array delete misuse(SCGCQ00804680)
 - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547)
 - Not able add new VD in Drive Group(SCGCQ00813314)
 - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939)
 - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049)
 - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299)
 - storcli /call show all fails with "command invalid"(SCGCQ00830269)
 - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342)
 - Profile Mgmt API Changes(SCGCQ00883008)
 - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417)
 - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738)
 - The code had events with repetitive ID and some structures clashing(SCGCQ00948535)
 - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835)
 - 800C error when execting Get MFC default function(SCGCQ01037840)
 - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936)
 - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284)
 - No ISE Capable field(SCGCQ01148693)
 - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175)
 - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698)
 - Fixing Resource leaks(SCGCQ01205356)
 - resource validation before de referencing(SCGCQ01206104)
 - Fixing resource leaks in libmods(SCGCQ01208044)
 - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393)
 - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414)
 - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473)
 - Fix for resource leak in system config show(SCGCQ01210133)
 - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415)
 - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383)
 - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923)
 - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217)
 - NVMe PD SMART DATA shows all 0's(SCGCQ01236052)
 - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715)
 - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381)
 - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687)
 - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688)
 - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928)
 - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421)
 - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632)
 - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445)
 - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336)
 - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979)
 - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883)
 - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094)
 - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474)
 - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620)
 - Some sparc structures missing for storcli.(SCGCQ00504585)
 - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761)
 - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658)
 - storecli reports wrong size on 3000MB VD(SCGCQ00644545)
 - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962)
 - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672)
 - Add support bits for uneven-span and SSHA support(SCGCQ00755063)
 - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101)
 - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924)
 - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290)
 - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959)
 - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385)
 - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937)
 - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714)
 - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759)
 - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347)
 - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363)
 - Storcli errors are printing in a different line.(SCGCQ00771626)
 - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302)
 - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332)
 - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577)
 - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800)
 - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357)
 - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202)
 - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761)
 - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393)
 - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335)
 - Resource leak(SCGCQ00804745)
 - .(SCGCQ00811452)
 - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672)
 - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205)
 - Fix for profile management support check bit(SCGCQ01208103)
 - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411)
 - Unified Storcli: Fixing resource leak issues(SCGCQ01209413)
 - SAS3.5 Ventura(SCGCQ01219196)
 - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153)
 - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169)
 - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376)
 - Need to handle FW return code change for profile management success case(SCGCQ01307320)
 - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263)
 - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644)
 - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663)
 - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978)
 - storcli /c0 show is not listinf SWR controller(SCGCQ00454971)
 - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116)
 - Raptor Galaxy : Storcli(SCGCQ00475562)
 - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981)
 - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771)
 - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763)
 - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073)
 - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800)
 - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416)
 - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775)
 - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174)
 - storelib header file changes porting(SCGCQ00609942)
 - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023)
 - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969)
 - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070)
 - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000)
 - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187)
 - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806)
 - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918)
 - Missing the Display of the property temperatureCtrl.(SCGCQ00792264)
 - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760)
 - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336)
 - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206)
 - Memory not freed which can cause leak(SCGCQ00804554)
 - Varailble need to be freed before returning in all failure case(SCGCQ00804650)
 - IDA show incorrect RAID controller type information(SCGCQ00806966)
 - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197)
 - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372)
 - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111)
 - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464)
 - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723)
 - Removing Unused and logically dead code in storcli(SCGCQ01204045)
 - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492)
 - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685)
 - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083)
 - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
 - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332)
 - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100)
 - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043)
 - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956)
 - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370)
 - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287)
 - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672)
 - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181)
 - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862)
 - CPLD(SCGCQ00787705)
 - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233)
 - rlListPtr is not handled properly in failure case(SCGCQ00796227)
 - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392)
 - LDViewMirror is giving segmentation fault(SCGCQ00830435)
 - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758)
 - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321)
 - Checking in compilation error for Libmods(SCGCQ00919973)
 - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356)
 - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055)
 - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407)
 - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101)
 - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553)
 - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709)
 - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745)
 - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950)
 - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070)
 - debug prints are present when issuing /co/eall show(SCGCQ00475815)
 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543)
 - Verify StorCLI warns on destructive operations(SCGCQ00712982)
 - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584)
 - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691)
 - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358)
 - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200)
 - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211)
 - Incorrect sizeof expression in dcmdprm(SCGCQ00793354)
 - Non-array delete for objects in rmdatamf(SCGCQ00793361)
 - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420)
 - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663)
 - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
 - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736)
 - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583)
 - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096)
 - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306)
 - PD related information missing for NVMe drives(SCGCQ01126564)
 - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365)
 - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854)
 - StorCLI(SCGCQ01274554)
 - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911)
 - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070)
 - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665)
 - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107)
 - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008)
 - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605)
 - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
 - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402)
 - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205)
 - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334)
 - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342)
 - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311)
 - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117)
 - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368)
 - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844)
 - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353)
 - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082)
 - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437)
 - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721)
 - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236)
 - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289)
 - Help for Compare linkspeed is not complete(SCGCQ01275454)
 - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037)
 - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491)
 - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067)
 - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426)
 - Libmod changes to support profile management(SCGCQ01048228)
 - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627)
 - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876)
 - Ventura PH3(SCGCQ01253012)
 - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455)
 - coverity removing out of bounds reads from code(SCGCQ01280460)
 - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999)
 - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085)
 - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234)
 - Resource leak in VdDataMf scanPartitions(SCGCQ00793363)
 - Storcli can't create AHCI LDs(SCGCQ00897637)
 - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676)
 - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024)
 - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214)
 - Detailed help missing for IT erase commands(SCGCQ01275474)
 - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671)
 - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453)
 
Enhancement
 
 - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167)
 - New fault code for routine synchronous reset(SCGCQ01264142)
 - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358)
 - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050)
 - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414)
 - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228)
 - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796)
 - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215)
 - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613)
 - API changes for CR55(SCGCQ01222700)
 - API change for Simplified RAID10 Creation(SCGCQ01222698)
 - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406)
 - API changes for PR SCGCQ01139678(SCGCQ01215334)
 - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 - API changes for PR SCGCQ01127742(SCGCQ01203751)
 - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 - MR 6.12(SCGCQ01146597)
 - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251)
 - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344)
 - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627)
 - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969)
 - MPI 2.5: Add new connector types(SCGCQ01085073)
 - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360)
 - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162)
 - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885)
 - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208)
 - MPI 2.5: update copyright info(SCGCQ00728066)
 - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829)
 - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820)
 - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175)
 - Add type BIOS for HashImageType.(SCGCQ00566306)
 - Identify physical location of a target device(SCGCQ00523879)
 - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817)
 - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293)
 - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819)
 - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437)
 - Allow Protection Information bit for IR Volume Create(SCGCQ00385306)
 - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551)
 - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271)
 - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270)
 - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266)
 - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260)
 - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506)
 - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383)
 - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439)
 - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131)
 - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055)
 - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759)
 - MPI 2.6: SOP Encapsulated request(SCGCQ00264755)
 - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183)
 - Libmods changes for EFI support for Unified storcli(SCGCQ00923719)
 - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101)
 - OEL Support for SPARC(SCGCQ00787923)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007)
 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477)
 - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399)
 - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735)
 - MPI 2.6: add IO Unit Control Request(SCGCQ00345258)
 - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272)
 - MPI 2.6: Enclosure Management(SCGCQ00345273)
 - Device Info field for PCIe devices(SCGCQ00353339)
 - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843)
 - MPI 2.6: new family values for ProductID fields(SCGCQ00360952)
 - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600)
 - Modified address space bits(SCGCQ00397136)
 - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563)
 - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568)
 - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572)
 - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577)
 - MPI 2.6: Add NVMe SGL support(SCGCQ00398256)
 - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541)
 - MPI 2.6: System Interface Register Set update(SCGCQ00464402)
 - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292)
 - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998)
 - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281)
 - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070)
 - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869)
 - MPI 2.6: Add new FLASH region types(SCGCQ00619371)
 - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271)
 - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957)
 - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527)
 - MPI 2.6: Extend Task Management(SCGCQ00686666)
 - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177)
 - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600)
 - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389)
 - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088)
 - MPI 2.6: add PCI Device ID's(SCGCQ00828497)
 - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588)
 - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827)
 - MPI 2.6: Update Flash Signature.(SCGCQ00852831)
 - profile management API(SCGCQ00867953)
 - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169)
 - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328)
 - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262)
 - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740)
 - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256)
 - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336)
 - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213)
 - MPI 2.6: Remove all SOP references(SCGCQ00925839)
 - Change library name to SLIT(SCGCQ00933175)
 - Ventura: de-feature AHCI(SCGCQ00941620)
 - MPI 2.6: Remove all AHCI references(SCGCQ00948258)
 - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955)
 - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638)
 - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619)
 - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104)
 - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930)
 - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826)
 - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027)
 - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687)
 - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473)
 - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741)
 - mega api changes for ibuttonless PR(SCGCQ01059740)
 - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009)
 - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374)
 - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821)
 - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340)
 - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549)
 - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837)
 - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839)
 - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127)
 - MPI 2.6: Add new clean tool options(SCGCQ01141732)
 - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583)
 - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725)
 - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092)
 - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367)
 - MPI 2.5: Signed images for FWDownload(SCGCQ00469990)
 - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512)
 - Display the Storelib version in the show command.(SCGCQ01286063)
 - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457)
 - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496)
 - Add support to allow Device names greater than 107(SCGCQ01039328)
 - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636)
 - Enable SED on JBOD(SCGCQ00755527)
 - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230)
 - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051)
 - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474)
 - Implemented the diag results to print on console(SCGCQ00525321)
 - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742)
 - MWCLI. Add HA support into storcli(SCGCQ00352120)
 - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668)
 - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607)
 - Add NVMe device related changes(SCGCQ01034678)
 - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665)
 - Complete 240VD support for utilities(SCGCQ00693042)
 - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287)
 - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311)
 - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793)
 - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715)
 - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821)
 - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146)
 - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204)
 - UDK Support for EFI(SCGCQ00795150)
 - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171)
 - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872)
 - Provide a way to enable or disable 512E using Applications(SCGCQ00351234)
 - Refer attached design doc(SCGCQ00349599)
 - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)
 - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050)
 - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217)
 - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344)
 - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473)
 - RRB 71(SCGCQ00750164)
 - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081)
 - SED/FDE changes for storcli Synchro(SCGCQ00632240)
 - ASD- StorCLI(SCGCQ00467863)
 - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209)
 - PERC 10 WIndows Support(SCGCQ01213160)
 - PERC 10 WIndows Support(SCGCQ01213157)
 - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080)
 - Megacli/storcli support for lmrc driver(SCGCQ00433703)
 - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093)
 - Uneven span support is added in StorCLI.(SCGCQ00349548)
 - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391)
 - Add EFI support for the manufacturing command to program.(SCGCQ01191095)
 - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216)
 - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476)
 - Monitoring Drive performance and predictive failure(SCGCQ00817977)
 - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118)
 - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237)
 - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987)
 - Functionality to extract field value from new API changes(SCGCQ00794841)
 - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815)

0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.

1.20.20 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227)
- Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335)
- Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866)
- Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811)
- Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074)
- Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438)
- Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663)
- Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140)
- Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401)
- Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258)
- Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358)
- Fixed an issue where storcli does not display description on command success - (SCGCQ01023973)
- Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081)
- Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945)
- Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534)
- Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430)
- Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535)
- Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218)
- Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102)
- Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484)
- Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534)
- Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745)
- Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757)
- Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895)
- Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068)
- Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105)
- Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314)
- Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646)
- Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899)
- Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101)
- Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120)
- Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669)
- Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997)
- Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082)
- Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011)
- Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071)
- Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117)
- Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416)
- Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387)
- Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154)
- Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907)
- Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447)
- Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139)
- Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493)
- Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500)
- Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028)
- Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669)
- Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536)
- Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554)
- Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode  - (SCGCQ01043063)
- Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322)
- Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608)
- Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994)
- Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298)
- Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300)
- Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088)
- Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805)
- Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035)
- Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084)
- Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706)
- Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613)
- Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775)
- Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973)
- Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830)
- Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940)
- Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786)
- Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464)
- Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466)
- Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876)
- Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415)
- Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985)
- Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968)
- Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027)
- Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756)
- Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306)
- Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841)
- Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876)
- Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525)
- Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798)
- Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620)
- Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204)
- Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274)
- Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667)
- Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604)
- Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055)
- Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533)
- Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614)
- Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474)
- Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758)
- Fixed an issue where some commands may not report success on success - (SCGCQ01050695)
- Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241)
- Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116)
- Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773)
- Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500)
- Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378)
- Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493)
- Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205)
- Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864)
- Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540)
- Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766)
- Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178)
- Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305)
- Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482)
- Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514)
- Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493)
- Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642)
- Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528)
- Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477)
- Fixed an issue where installaton of storclio may fail - (SCGCQ00952422)
- Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981)
- Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790)
- Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315)
- Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178)
- Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865)
- Fixed an issue where EPD details may not show in "show all" command  - (SCGCQ00921937)
- Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624)
- Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489)
- Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330)
- Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837)
- Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484)
- Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697)
- Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461)
- Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597)
- Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760)
- Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891)
- Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993)
- Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617)
- Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault"  - (SCGCQ01020010, Port of SCGCQ01019547)
- Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212)
- Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145)
- Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101)
- Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181)
- Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177)
- Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789)
- Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable  - (SCGCQ01143941, Port of SCGCQ01026187)
- Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307)
- Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download  - (SCGCQ01110108, Port of SCGCQ00934755)
- Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211)
- Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584)

Enhancements:
- Added the personality change command was not present - (SCGCQ00850610)
- Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220)
- Added multipath support in EPD configuration options - (SCGCQ01015758)
- Added additional CPU support on EFI platform - (SCGCQ01026250)
- Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304)
- Added personality change features - (SCGCQ01111930)
- Added VF-queue depth mode settings - (SCGCQ00907072)
- Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320)
- Added Secure Erase support to JBOD and System drives - (SCGCQ00929757)
- Added a JBOD entity for various operations - (SCGCQ01047229)
- Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064)
- Added more specific error messages in some circumstances - (SCGCQ00920034)
- Added new compilation environment and makefiles - (SCGCQ00920058)
- Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739)
- Added support for drive microcode update Modes E and F - (SCGCQ01047223)
- Added code to display JBOD personality - (SCGCQ01146775)
- Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338)
- Added new erase type called Crypto - (SCGCQ01050618)
- Added new command to set the multiInit EPD parameter - (SCGCQ01080273)
- Added support for drive microcode update through parallel loading - (SCGCQ01024964)
- Added support for EPD creation - (SCGCQ00887664)
- Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414)


1.18.11 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705)
- Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785)
- Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612)
- Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196)
- Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339)
- Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620)

Enhancements:
- Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662)
- Added the support to set and clear the transport on a DG (SCGCQ00920046)
- Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318)
- Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795)
- Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030)
- Provide a more descriptive port enumeration (SCGCQ00854620)
- Add support to enable/Disable of Large IO Support (SCGCQ00894644) 

1.16.14 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617)
- Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176)
- Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715)
- Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755)

1.16.10 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617)
- Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470)
- Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914)
- Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143)
- Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429)
- Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770)


1.14.12 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Incorporated StorCLI MegaRAID 6.6 stream

Enhancements:
- Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171)
- Added consistent sorting of controllers using bus, device, function (SCGCQ00696872)
- Added ability to enable or disable 512e support (SCGCQ00351234)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527)
- Added ability for VMWare version to be run from any directory (SCGCQ00642230)
- Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477)
- Added ability to create a RAID00 (SCGCQ00350668)
- Added ability to display the Patrol Read Start Time (SCGCQ00564474)
- Added learn cycle progress information in show learn command (SCGCQ00644984)
- Added support for uneven spans (SCGCQ00349548)
- Added support for lmrc driver (SCGCQ00433703)
- Added 240 Virtual Drive support (SCGCQ00693042)
- Improved Punctured Block logging (SCGCQ00342399) 

1.12.15 - Moderate Impact/Low Probability of Occurrence
-------
Fix(es):
 - Prevent storCLI from allowing users to enable JBOD mode on
   controllers that do not support JBOD mode.
 - Updated CACHEBYPASS command to line up with user expectation.  When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass.

1.07.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M1215 SAS/SATA Controller
Fix(es):
 - Fixed an issue where segmentation faults may occur in Linux.
 - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS.
 - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying.

1.04.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M5210e and ServeRAID M5210
Fix(es):
 - Fixed an issue where a command failure results in subsequent commands and actions failing.
 - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR.
 - Added help file for for storcli /cx/dx set security
 - Fixed an issue where the "show ctrlcount help" command is not displaying properly.
 - Fixed an issue where a failure is displayed in the output for querying dimmer switch information.
 - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM.
 - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives.
 - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed.
 - Synced the pause pr command with show pr command to show correct PR Current State.
 - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property.

1.03.11 - Initial release
-------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved