Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): NeXtScale nx360 M5 (5465)
Targeted Operating System: SLES12SP3
YUM Repository Build Date: 2019_04_23

YUM Repository Release Version: 19A

Device:
ServeRAID M1215 SAS/SATA Controller

Device Product Guide

Part Number: 46C9114
Feature Code: na
PCIe Sub Vendor ID: 0x1014
PCIe Sub Device ID: 0x0456


Release History:
Release: 19A
Change History Documents
Firmware Firmware Name Version
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers 1200-24.21.0-0084-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.707.04.00_sles12sp3-1.x86_64.rpm 07.707.04.00_k4.4.73_5
Utilities Utility Name Version
LSI Storage Authority Software for windows and linux 004.189.000.000
StorCLI command line tool for anyos storcli-007.0713.0000.0000
MegaRAID Storage Manager Application 17.05.01.03

Release: 18D
Firmware Firmware Name Version
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers 1200-24.21.0-0067-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.705.05.00_sles12sp3-1.x86_64.rpm 07.705.05.00_k4.4.73_5

Release: 18B
Firmware Firmware Name Version
BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers 1200-24.21.0-0052-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.705.04.00_sles12sp3-1.x86_64.rpm 07.705.04.00_k4.4.73_5


Release 19A Change History Documents

BIOS and Firmware Update for ServeRAID M1200 Series SAS/SATA Controllers



ServeRAID M1200 Series SAS/SATA Controller Firmware Update

Supported Adapters:  
- ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
- ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
- M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
- M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node


NOTE TO SERVICE - Reference RETAIN #N/A

Version 24.21.0-0084-1 - Moderate Impact/Low Probability of Occurrence
--------------------
MR/iMR 6.14

PACKAGE: 24.21.0-0084
BIOS: 6.36.00.3
UEFI Driver: 0x06180203
HII: 03.25.05.11
NVDATA: 3.1705.00-0018
iMR NVDATA - 3.1705.01-0012
Firmware - 4.680.00-8434
iMR Firmware - 4.680.01-8435

Defects:
- SATA SSD not discovered by OS during hibernate test.(SCGCQ01949781)
- Intruder and Invader controllers returnning vpd86 error.(SCGCQ01929277)
- FW reports that the board passed BBU Retention test on boards that have a non operational ONFI NAND memory.(SCGCQ01891177 Port Of Defect SCGCQ01934351)
- Invader IMR : PD fails to get marked as foreign on insertion.(SCGCQ01950845 Port Of Defect SCGCQ01955263)
- Preserved Cache doesn't flush back during Foreign Import.(SCGCQ01466831 Port Of Defect SCGCQ01904085)

Version 24.21.0-0076 - Moderate Impact/Low Probability of Occurrence
--------------------
PACKAGE:  24.21.0-0076
BIOS:  6.36.00.3
UEFI Driver:  0x06180203
HII:  03.25.05.10
NVDATA: 3.1705.00-0018
iMR NVDATA - 3.1705.01-0012
Firmware - 4.680.00-8417
iMR Firmware - 4.680.01-8418

Version 24.21.0-0067-2 - Moderate Impact/Low Probability of Occurrence
--------------------
PACKAGE:  24.21.0-0067
BIOS:  6.36.00.3
UEFI Driver:  0x06180203
HII:  03.25.05.10
NVDATA: 3.1705.00-0016
iMR NVDATA - 3.1705.01-0011
Firmware - 4.680.00-8392
iMR Firmware - 4.680.01-8393

Defects (8)
- 'CacheVault Flash Size' is showing as 3.0 GB after upgrading FW when it should show 4.0 GB.(SCGCQ01615779)
- criteo: Storcli shows R0 VD as WB in JBOD personality where as FW shows in WT mode.(SCGCQ01714445)
- Revert code changes from CSET SCGCQ01569257.(SCGCQ01717743)
- Customer specific 3108 PCIe add-on card fails to come back while resuming from sleep state S.(SCGCQ01718911)
- FW returns success for enabling encryption when it is failed on the drives.(SCGCQ01830718)
- Line 535 in ../../raid/cachePreserve.c for trying to create Pinned Cache by Cable Pull..(SCGCQ01839662)
- memset the deviceStateLedBitmap properly.(SCGCQ01844264)
- OOB SCSI passthru command (READ DEFECT 12) return without response data.(SCGCQ01793262)
- FW is observing Kill Adapter while CCVD disassociate in progress.(SCGCQ01186806 port of SCGCQ01172369)
- Update the MAXTransferLength properly for Driver enabled 1MB support feature.(SCGCQ01238543 port of SCGCQ01232275)
- FW crashes when FW update(OFU) is done with faluty onfi.(SCGCQ01249569 port of SCGCQ01227115)
- irq handler flooding taskqueue and persistent ID removal corrupting memory.(SCGCQ01399132 port of SCGCQ01299784)
- Firmware allows to add bad blcoks beyond actual number of blocks..(SCGCQ01430024 port of SCGCQ01403292)
- MCTP: Addressing PCIe credirt free issue..(SCGCQ01447186 port of SCGCQ01446811)
- Firmware discovery is not listing all the drives after removal/insert Enclosure Cable with IO.(SCGCQ01579250 port of SCGCQ01555943)
- MR FW memory Leak across driver load/unload.( SCGCQ01579251port of SCGCQ01573393)
- With controller operating in least latency mode, FW hits montask upon running IOs.(SCGCQ01587048 port of SCGCQ01116419)
- Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01635416 port of SCGCQ01623254)
- Issue: JBOD devices were dropped after unloading driver and reloading driver in linux.(SCGCQ01639846 port of SCGCQ01566087)
- : FW asserts when invalid parameters to set excluded ld for CC is sent to firmware..(SCGCQ01670394 port of SCGCQ01635729)
- Colusa SAS expander reset results in unpredictable performance.(SCGCQ01697517 port of SCGCQ01455811)
- MR 7.6 - "NVCache has gone bad" during POST after flashing the latest package 1226 and rebooted.(SCGCQ01714326 port of SCGCQ01635062)
- When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM..(SCGCQ01715349 port of SCGCQ01676080)
- F/W Hangs during reboot.(SCGCQ01716602 port of SCGCQ01616551)
- MR7.6: Firmware hit montask running task management reset in loops.(SCGCQ01727364 port of SCGCQ01675742)
- When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM.(SCGCQ01729680 port of SCGCQ01676080)
- LAS does not show proper state of secured locked drives..(SCGCQ01732045 port of SCGCQ01615781)
- F/W Hangs during reboot.(SCGCQ01758976 port of SCGCQ01616551)
- Pd firmware download timer is calculated accordingly.(SCGCQ01758988 port of SCGCQ01669508)
-.(SCGCQ01763953 port of SCGCQ01749090)
- Smart Return Status passthru command failed on SATA drives.(SCGCQ01806402 port of SCGCQ01555033)
- LAS does not show proper state of secured locked drives..(SCGCQ01807819 port of SCGCQ01615781)
-.(SCGCQ01838484 port of SCGCQ01807938)
- 9460-8i is reporting Chip Temperature of 255 when the ambient temp is about 0 C.(SCGCQ01850339 port of SCGCQ01565568)
- Found invalid event.(SCGCQ01375915 port of SCGCQ01347858)
- 9460-16i disappears from F1 setup after encrypting SED.(SCGCQ01565312 port of SCGCQ01326871)
- Sanitize Support.(SCGCQ01577753 port of SCGCQ01526323)
- Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01633668 port of SCGCQ01623254)
- Sanitize progress in TTY log showing incorrect elapsed time.(SCGCQ01681594 port of SCGCQ01630577)
- Pd firmware download timer is calculated accordingly.(SCGCQ01682987 port of SCGCQ01669508)

EnhancementRequests (11)
- Integrate phase 12 PL (12.00.13.00) with MR 6.12.(SCGCQ01580766)
- FW change: Request to add NVDATA and PNP IDs for new card introduction.(SCGCQ01826466)
- Integrate Intruder Phase 14 PL - 14.00.10.00 Firmware MR PL Release.(SCGCQ01764776)
- Criteo: API changes reversal.(SCGCQ01760512)
- PL Integration: Integrate Intruder PL phase 13.00.10.00 with MR 6.13 Intruder.(SCGCQ01698033)
- PL Integration : Integrate Invader phase 12.00.14.00 PL with MR 6.12.(SCGCQ01716598)
- RTTrace API Changes.(SCGCQ01745568)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled..(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not..(SCGCQ01762153)
- PL Integration: Integrate Invader Phase 13.00.10.00 PL with MR 6.13 Invader.(SCGCQ01698045)

Version 24.21.0-0052-1 - Moderate Impact/Low Probability of Occurrence
--------------------
PACKAGE:  24.21.0-0052
BIOS:  6.36.00.2
UEFI Driver:  0x06180202
HII:  03.25.05.04
NVDATA: 3.1705.00-0014
iMR NVDATA - 3.1705.01-0011
Firmware - 4.680.00-8353
iMR Firmware - 4.680.01-8354

Defects (42)
- Intruder Controller Disappear during clean shutdown on OEM server.(SCGCQ01375977)
-.(SCGCQ01753405)
-.(SCGCQ01749090)
- When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM..(SCGCQ01676080)
- Pd firmware download timer is calculated accordingly.(SCGCQ01669508)
- IO path function accessed by both core is not synchonized..(SCGCQ01640234)
- False alarm of "cache Discarded" when the System, with Invader controller + WT R5 volume, is shutdown normally..(SCGCQ01627751)
-.(SCGCQ01623408)
- Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01623254)
- MR FW memory Leak across driver load/unload.(SCGCQ01573393)
- Incorrect Micron NAND Model Number read from flash.(SCGCQ01531136)
- MR_6.14 PACK 23 - On performing a cable pull/push operation during drive is in failed state, result to MonTask.(SCGCQ01529830)
- [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01497858)
- IO access to iMR FW will fail after sveral powercycle.(SCGCQ01494761)
- iMR Compilation fails even with RELEASE option in 6.12 after taking errata MR workaround SCGCQ01323607 and its child defects.(SCGCQ01494566)
- SED Drive become UBad during secure erase on MegaRAID 9361-8i controller.(SCGCQ01473188)
- 6.14 : Reverting the sysDma changes.(SCGCQ01465727)
- On iMR Invader & for 2 enclosures connected in cascaded multi path , power off and then power on the 1st enclosure, PDs not getting detected.(SCGCQ01455949)
- Firmware upgrade/downgrade operation failing on SKINNY controller.(SCGCQ01455133)
- MCTP: Addressing PCIe credirt free issue..(SCGCQ01446811)
- Parameter Page Invalid, Setting channel count based on DDR Size..(SCGCQ01440768)
- FW breaks into montaks with pinned cache and foreign configuration.(SCGCQ01378970)
- FW reported tmm Date of Manufacture 15/25/6.(SCGCQ01395084)
- Interrupting Offload will Lead to Next offload cycle to fail.(SCGCQ01399701)
- Enable WB support via API.(SCGCQ01405242)
- F/W Hangs during reboot.(SCGCQ01616551)
- iMR compilation breaks, exceeding 1MB flash region allocated.(SCGCQ01520940)
- Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01514867)
- Workaround for IO access to iMR FW will fail after sveral powercycle on 3004 controller..(SCGCQ01507504)
- linker error resolved.(SCGCQ01472217)
- Problem with I2C Slave communication with external Masters that don’t support slave clock stretching..(SCGCQ01443277)
- MR : Cache data Lost when Term Log is set to "on" and grown bad blocks are there in the controller.(SCGCQ01394288)
-.(SCGCQ01400707)
- Learn cycle shown as active when Learn cycle fails.(SCGCQ01400807)
- Firmware allows to add bad blcoks beyond actual number of blocks..(SCGCQ01403292)
- OCR getting disabled after NVRAM delete.(SCGCQ01719006)
- MCTP : Porting of firmware download fixes from Ventura.(SCGCQ01439651)
- NVCache state not transitioning from 'Faulty' to 'Ok' until after reboot.(SCGCQ01395724)
- Intermittent: On iMR_Invader & cascaded Enclosures, after power off the enclosure, FW holds the PD info and apps display PDs.(SCGCQ01483727)
- controller VPD info is hidden as per OEM request.(SCGCQ01454973)
- SSD SATA JBOD discovered as 0.0MB after re-loading the same driver..(SCGCQ01446965)
- Firmware discovery is not listing all the drives after removal/insert Enclosure Cable with IO.(SCGCQ01555943)
- Infinite loop in onfiSyncModeEnter.(SCGCQ01259314 port of SCGCQ00329024)
- HW workaround implementation for SCGCQ00830272 and SCGCQ01048567.(SCGCQ01326393 port of SCGCQ01323607)
- MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address.(SCGCQ01334364 port of SCGCQ01332947)
- Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348660 port of SCGCQ01304521)
- Resulting R0 VD is showing as not consistent after reconstruction..(SCGCQ01348998 port of SCGCQ01288897)
- Imr Invader FW crashes while upgrading from Pkg 24.18.0-0021 to Pkg 24.21.0-0007..(SCGCQ01351814 port of SCGCQ01342601)
- Intruder 4G DDR tuning value has to be changed in MR FW..(SCGCQ01369344 port of SCGCQ01368845)
- Found invalid event.(SCGCQ01375914 port of SCGCQ01347858)
- Placement of an image checkword at data area of NOR flash leads to controller crash.(SCGCQ01375943 port of SCGCQ01375071)
- Block OCR after Clearing NVRAM.(SCGCQ01392471 port of SCGCQ01386919)
- Block OCR after Clearing NVRAM.(SCGCQ01394920 port of SCGCQ01386919)
- SCS/PL debug logs for "rb", "tb", or "dmdiag pl dbg" are sometimes mangled due to multiple mprintf's overlapping.(SCGCQ01399457 port of SCGCQ01283702)
- RedBrick controller hang at DCR Err Logg Address 29e02..(SCGCQ01412795 port of SCGCQ01375159)
- RedBrick controller hang at DCR Err Logg Address 29e02..(SCGCQ01412827 port of SCGCQ01375159)
- LSA hangs when user try to change drive security key..(SCGCQ01412848 port of SCGCQ01342655)
- B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B).(SCGCQ01412896 port of SCGCQ01271186)
- Parameter Page Reads fail during ONFI bringup..(SCGCQ01415428 port of SCGCQ01413557)
- heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421932 port of SCGCQ01411591)
- heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421933 port of SCGCQ01411591)
- heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421934 port of SCGCQ01411591)
- Revert the DDR tuning values back to default value.(SCGCQ01446963 port of SCGCQ01444640)
- PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01446983 port of SCGCQ01399026)
- MCTP: Addressing PCIe credirt free issue..(SCGCQ01447187 port of SCGCQ01446811)
- Parameter Page Invalid, Setting channel count based on DDR Size..(SCGCQ01447901 port of SCGCQ01440768)
- Drives in Enclosure spin up values for OEM board is not initialized correctly.(SCGCQ01466081 port of SCGCQ01450221)
- IOMMU fault at address 0x80360000.(SCGCQ01473355 port of SCGCQ01279547)
- Enable DO_REAL_TIME_ISP and DO_DISABLE_ISP_CLAMP flags while flashing CPLD for Intruder cards.(SCGCQ01503730 port of SCGCQ01452026)
- SED Drive become UBad during secure erase on MegaRAID 9361-8i controller.(SCGCQ01503736 port of SCGCQ01473188)
- [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01519905 port of SCGCQ01497858)
- MR_6.14 PACK 23 - On performing a cable pull/push operation during drive is in failed state, result to MonTask.(SCGCQ01532358 port of SCGCQ01529830)
- OCR is disabled by default is RC build, even NVDATA if it is enabled..(SCGCQ01540279 port of SCGCQ01503204)
- MR7.1/7.3 Termlog/UARTlog - messages sometimes missed in Termlog.(SCGCQ01540361 port of SCGCQ01498188)
-.(SCGCQ01569257 port of SCGCQ01097035)
- If an INVALID applicationMsgTag id received, then failed the command with MFI_OOB_STATUS_INVALID_CMD using command id MAX_OOB_COMMANDS..(SCGCQ01575976 port of SCGCQ01337332)
- Sanitize Support.(SCGCQ01577752 port of SCGCQ01526323)
- SATA PassTrough commands with check condition taking long time to complete..(SCGCQ01582512 port of SCGCQ01561887)
- VMware Passthrough Adapter does not sync time on VM power on.(SCGCQ01595865 port of SCGCQ01592800)
- Jbod become Ugood sometimes after reboot.(SCGCQ01616609 port of SCGCQ01508978)
- Colusa SAS expander reset results in unpredictable performance.(SCGCQ01618030 port of SCGCQ01455811)
- 'CacheVault Flash Size' is showing as 3.0 GB after upgrading FW when it should show 4.0 GB.(SCGCQ01640816 port of SCGCQ01615779)
- Drives are reverted back to JBOD after perfoming instant secure erase.(SCGCQ01683366 port of SCGCQ01615777)
- MR7.1/7.3 Termlog/UARTlog - messages sometimes missed in Termlog.(SCGCQ01714377 port of SCGCQ01498188)
- In HII whether entering the correct pass phrase or the wrong pass phrase a secured SED becomes unsecured.(SCGCQ01715297 port of SCGCQ01301947)
- B200 M5 / Carmel (3108 iMR) - VSAN failure during controller reset test.(SCGCQ01760837 port of SCGCQ01397566)
- MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations.(SCGCQ01339329 port of SCGCQ01332706)
- MR : Cache data Lost when Term Log is set to "on" and grown bad blocks are there in the controller.(SCGCQ01403930 port of SCGCQ01394288)
- Interrupting Offload will Lead to Next offload cycle to fail.(SCGCQ01403958 port of SCGCQ01399701)
- SSD SATA JBOD discovered as 0.0MB after re-loading the same driver..(SCGCQ01447007 port of SCGCQ01446965)
- MCTP : Porting of firmware download fixes from Ventura.(SCGCQ01447173 port of SCGCQ01439651)
- Controller crash observed while running OLTP workload (4K and 16K 16QD).(SCGCQ01447780 port of SCGCQ01438216)
- PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01467708 port of SCGCQ01399026)
- [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01519906 port of SCGCQ01497858)
- Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01521684 port of SCGCQ01514867)
- Event Log Corruption..(SCGCQ01532399 port of SCGCQ01451417)
- Rebuild Rate %100 takes much longer time than %30 while running IO. It should take much shorter time..(SCGCQ01540424 port of SCGCQ01336908)
- Controller crash observed while running OLTP workload.(SCGCQ01565253 port of SCGCQ01447773)
- OEM iMR 8i controller fails to complete an OCR.(SCGCQ01565318 port of SCGCQ01330611)
- Snap3 : Drives drops while running transformation operation on R1 to R5 with 900 Medium errors.(SCGCQ01598538 port of SCGCQ01581661)
- LSA shows Stop Erase option for VDs on which Erase operation is not in progress.(SCGCQ01605097 port of SCGCQ01600267)
- Memset the PinnedDataStructure when DRAM dirty signature is zero.(SCGCQ01724925 port of SCGCQ01713149)
- Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348657 port of SCGCQ01304521)
- Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348658 port of SCGCQ01304521)
- FW is not correctly reporting Hide VD operation as not supported.(SCGCQ01348841 port of SCGCQ01274084)
- MR7.3: 4k PD Configuration can't be imported from iMR to MR Controller. However, it can be imported from MR to iMR.(SCGCQ01402828 port of SCGCQ01395842)
- PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01467725 port of SCGCQ01399026)
- Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01520788 port of SCGCQ01514867)
- MR 7.6 - "NVCache has gone bad" during POST after flashing the latest package 1226 and rebooted.(SCGCQ01683358 port of SCGCQ01635062)
- Controller hang with FDE Drive (Micron 510DC).(SCGCQ01328038 port of SCGCQ01304133)
- Assertion failure in ../../mros/mem.c : mb->tag==tag.(SCGCQ01539460 port of SCGCQ01515324)
- Parameter Page Reads fail during ONFI bringup..(SCGCQ01415424 port of SCGCQ01413557)
- If an INVALID applicationMsgTag id received, then failed the command with MFI_OOB_STATUS_INVALID_CMD using command id MAX_OOB_COMMANDS..(SCGCQ01512549 port of SCGCQ01337332)



EnhancementRequests (47)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- Provide customized default smartpollinterval to 30 for iMR3004 product.(SCGCQ01748252)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- Memset the PinnedDataStructure when DRAM dirty signature is zero.(SCGCQ01713149)
- Integrate latest phase 14.0 - 14.00.08.00 PL with MR 6.14.(SCGCQ01682170)
- as per customer request enabled FBU02 and 4G TFM support.(SCGCQ01681106)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Integrate latest phase 14 PL with MR 6.14.(SCGCQ01593998)
- Integrate Invader Phase 14 PL - 14.00.06.00 Firmware MR PL Release.(SCGCQ01589431)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Integrate Intruder phase 14 PL - 14.00.08.00 with MR 6.14 Intruder.(SCGCQ01459161)
- customer request for GPIO support..(SCGCQ01452102)
- Enable DO_REAL_TIME_ISP and DO_DISABLE_ISP_CLAMP flags while flashing CPLD for Intruder cards.(SCGCQ01452026)
- Fail to Set SSDSmartErEnabled to TRUE when copyback is disabled.(SCGCQ01403999)
- PL 14.00.07.00 intgration to MR 6.14 intruder..(SCGCQ01401110)
- Integrate phase 14 Intruder PL - 14.00.06.00 with MR 6.14.(SCGCQ01386225)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
-.(SCGCQ01389581)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Request to enable JBOD for Rambler PNP ID.(SCGCQ01727448)
- Reverted the DDR tuning values.(SCGCQ01625968)
- Porting the changes of NVRAM_Struct from MesaVerde stream to 6.14.(SCGCQ01563144)
- Enhance Messaging Unit error ISR to dump debug information of virtual functions having error.(SCGCQ01553249)
- CacheCade: IO performance need to be improved for WB SVD and WB CCVD combination for specific PnP ID.(SCGCQ01472061)
- FW breaks into montaks with pinned cache and foreign configuration.(SCGCQ01403814)
- Boot message string change for BOOT_MSG_CACHE_DISCARD.(SCGCQ01394348)
- Block OCR after Clearing NVRAM.(SCGCQ01386919)
- PL 14.00.05.00 Integration with Invader MR 6.14.(SCGCQ01384265)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
 FW to fail back host command for the wrong value.(SCGCQ01575960)
- Setting DDR flag for ROMB design having new DDR for an OEM.(SCGCQ01466802)

Version 24.21.0-0016-03 - Moderate Impact/Low Probability of Occurrence
-------------------
HII: 03.25.05.03
UEFI Driver: 0x06180202
BIOS: 6.36.00.1_4.19.08.00_0x06180202
iMR FW: 4.680.01-8257
PACKAGE=24.21.0-0016

Defects:
 - Try to update HBA cards' firmware when there is HBA card installed

Version 24.21.0-0016 - Moderate Impact/Low Probability of Occurrence
-------------------
HII: 03.25.05.03
UEFI Driver: 0x06180202
BIOS: 6.36.00.1_4.19.08.00_0x06180202
iMR FW: 4.680.01-8257
PACKAGE=24.21.0-0016

Defects:

Fixes:
 -  MR 6.13: Blocked Spin down Pass thru command for configured drives.(SCGCQ01201958)
 -  In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01213915)
 -  Setting all the ldtoTgtId with 0xff beyond 240 entries.(SCGCQ01215003)
 - (SCGCQ01219438)
 -  MR_EVT_PD_ERROR_STATS events are logged when drive is moved to REBUILD/UNCONFIGURED BAD/ONLINE/OFFLINE. Also(SCGCQ01223284)
correct DCMD
 -  FW crashes when FW update(OFU) is done with faluty onfi(SCGCQ01227115)
 -  Coverity issues:fixed the coverity defects.(SCGCQ01230560)
 -  Update the MAXTransferLength properly for Driver enabled 1MB support feature(SCGCQ01232275)
 -  Assertion failure in ../../dm/mpt2/mptrec.c at line 3139, while performing cable pull/push operation.(SCGCQ01235505)
 -  corrected the span index(SCGCQ01236287)
 -  Coverity issue 15748 and 17765(SCGCQ01241568)
 -  Drive Strength values are incorrect for last 8 phys of Red Brick Controller(SCGCQ01241680)
 -  Change Slew Rate on dual rank RedBrick Boards to fix ECC Errors.(SCGCQ01242817)
 -  Cache Data lost if power loss happens during descriptor preparation.(SCGCQ01253076)
 -  'C0:mr_wakeup: mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors.(SCGCQ01256120)
 -  Assertion failure in ../../raid/2108vI2o.c at line 2398 on flashing firmware(SCGCQ01258563)
 -  Dev defect to address action items identified during Ventura(SCGCQ01260609)
 -  Dev defect to handle HW action items identified during Intruder(SCGCQ01261213)
 -  Cache data Lost when Term Log is set to "on"(SCGCQ01261426)
 -  6.13 ONFI_PORT: If power loss occurs after OCR, FW might lose tty log.(SCGCQ01262834)
 -  6.13_ONFI_PORT: Program the erase and wait count values during ONFI Initialization.(SCGCQ01262883)
 -  6.13 ONFI PORT :Set bit 0 in global Interrupt Register so that host will receive an interrupt.(SCGCQ01262884)
 -  Flash File System Reads fail after system reset.(SCGCQ01267220)
 -  FW does not remember user induced bad blocks across boots.(SCGCQ01267700)
 -  MR 6.13(SCGCQ01268066)
 -  Unable to access device PD (SSD)(SCGCQ01268412)
 -  MR_6.13:FW flash pack (SCGCQ01273216)
 -  Cache Restore fails if supercap is removed while cache offload is in Progress.(SCGCQ01274494)
 -  Unable to set termlog on/off from storcli intermittently on Intruder Armstrong board.(SCGCQ01278512)
 -  Storcli Failed to create single PD R0 from UGood drive which has replaced a UBAD foreign drive(SCGCQ01282181)
 -  Intruder : After Termlog Toggling with power cycle, result to ERROR: Dirty disk cache data has been lost(SCGCQ01282319)
 -  Modify Read Eye Training Algorithm to make it spec compliant.(SCGCQ01283719)
 -  High DB and Log write(SCGCQ01285311)
 -  Coverity reported an uninitialized variable(SCGCQ01285595)
 -  OS hung and iMR FW reset when do delete and create VD from previous powersave PD (Spindowned)(SCGCQ01287286)
 -  Reboot the system with 240 R0 Volumes and changing the mode(SCGCQ01288297)
 -  PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01288781)
 -  erase types and startSecureEraseNonSED is set accordingly(SCGCQ01289147)
 -  Modify NVDATA boot message to rename 'NVDATA image' to 'firmware image'(SCGCQ01290201)
 -  Cache data lost event seen for WT vds(SCGCQ01313607)
 -  Kill adapater observed while running IO's on 240 Volumes(SCGCQ01313950)
 -  Coverity: Fixing Coverity defect 16148(SCGCQ01316152)
 -  Fixing the coverity raised issue(SCGCQ01318465)
 -  Coverity issue 19341(SCGCQ01319291)
 -  HW workaround implementation for SCGCQ00830272 and SCGCQ01048567(SCGCQ01323607)
 -  auto config is not happening in some cases after issuing storcli /cx set autopdcache=r0(SCGCQ01323848)
 -  MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations(SCGCQ01332706)
 -  MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address(SCGCQ01332947)
 -  ntruder: Fix the Intruder Boot Block compilation and warning issue.(SCGCQ01334292)
 -  Imr Invader FW crashes while upgrading from Pkg 24.18.0(SCGCQ01342601)
 -  No amber LED when a configured disk is removed(SCGCQ01343017)
 -  Controller fails to boot up when migrated from 6.13 to 6.14 FW for Specific OEM(SCGCQ01348114)
 -  Value defined for the DDR turning parameter DP_IO_VREF_1_2 is wrong for invader boards(SCGCQ01350295)
 -  MR_INVADER_WORKAROUND_PCIE_IGNORE_REPLY_PARITY_ERROR macro definition missing(SCGCQ01351483)
 -  Intruder 4G DDR tuning value has to be changed in MR FW.(SCGCQ01368845)
 -  Lenovo Sebastian Fatal Firmware error when connecting to straight without Group ID support.(SCGCQ01204592)
 -  FW does not fail unsupported erase type for a PD(SCGCQ01221549)
 -  Allow Cyrpto erase on non(SCGCQ01222318)
 -  Fix coverity reported issue(SCGCQ01227079)
 -  FW is not updating EPDs list exposed to host after drives removal event is posted which is causing dev nodes are not getting deleted on(SCGCQ01230441)
drive removal
 -  Diagnostics report of iMR Invader contains information about R6 and R60 is set to 0(SCGCQ01235661)
 -  Enable MR_DCMD_PD_ERROR_STATS and the event MR_EVT_PD_ERROR_STATS only for direct attached drives(SCGCQ01237252)
 -  DATA TLB ERROR, While connecting controller each Port to Back(SCGCQ01252111)
 -  MR 6.13.1Alpha:Probable Drive/cable issue Event not printed in firmwarelogs on triggering drive/cable error when connected BP(SCGCQ01256005)
 -  Handling of DCR errors in MSS core(SCGCQ01263110)
 -  Controller does not boot up while performing cache offload .(SCGCQ01278480)
 -  Controller cache discarded due to memory/battery problem(SCGCQ01280181)
 -  Perf(SCGCQ01283507)
 -  Code review: turn off the onfi when bbu is bad(SCGCQ01297565)
 -  Coverity issues 19244, 19245, 19246 and 19248(SCGCQ01299214)
 -  MR 6.14 Intruder(Vail): Intruder Controller hangs in primary core on reboot in Dell Power Edge T620 server.(SCGCQ01299482)
 -  Fix coverity issue 19253 Structurally dead code in checkCacheOffloadStatus, raid/1078init.c(SCGCQ01300678)
 -  coverity defects fixed(SCGCQ01300689)
 -  To fix coverity issue 17759(SCGCQ01317039)
 -  Found invalid event(SCGCQ01347858)
 -  Placement of an image checkword at data area of NOR flash leads to controller crashPage 2 / 42(SCGCQ01375071)
 - (SCGCQ01227044)
 -  FC: 0 CS: 0 offload meta signature not valid, ffffffff observed in FW logs on a system restart.(SCGCQ01299424)
 -  MR 6.14 (SCGCQ01300667)
 -  Coverity issue 15356(SCGCQ01301658)
 -  update the boundary values in UpdateFeatureSetValues()(SCGCQ01209605)
 -  FW hang finaly leading to kill adatper with inBox driver(SCGCQ01250342)

Enhancements:
 -  New fault code for routine synchronous reset(SCGCQ01264142)
 -  Vail FW not responding to PWR_REQ in time. Request to up the number of TURs sent before timing out drive.(SCGCQ01373161)
 -  Disable OOB communication via I2C(SCGCQ01369359)
 -  Integrate Intruder PL 14.00.04.00 with MR 6.14(SCGCQ01341925)
 -  PL phase 13.0007.00 integration with MR 6.13(SCGCQ01334112)
 -  PL integration(SCGCQ01330898)
 -  Integrate PL phase 14.00.02.00 with MR 6.14(SCGCQ01307233)
 -  Integrate 13.00.06.00 PL to MR 6.13(SCGCQ01304141)
 -  PL integration 12.00.10.00 with MR 6.12(SCGCQ01276465)
 -  Integrated PL 12.0.9.0 with MR 6.12(SCGCQ01268897)
 -  Shift IOPATH code by 4 cache lines to workaround intruder performance issue.(SCGCQ01262698)
 -  PR State Machine Clean up during Patrol Read/Check Consistency Conflicts(SCGCQ01260431)
 -  Integrate intruder PL 13.00.04.00 (SCGCQ01237533)(SCGCQ01238286)
 -  Integrate PL 13.00.04.00 to MR_FW_SAS3_6.13_4G_DDR(SCGCQ01238126)
 -  Open up MR_DCMD_CFG_AUTOCFG for iMR for GET operation(SCGCQ01228949)
 -  Customer requesting digitally signed FW packages on their Intruder controller(SCGCQ01215397)
 -  MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 -  MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 -  MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 -  MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 -  MPI 2.6: Device side PCIe SRNS flag(SCGCQ01276256)
 -  MPI 2.6: Add new firmware download type (CPLD IMAGE)(SCGCQ01305760)
 -  IN FAILED ARRAY bit is not being set when a VD is cleared(SCGCQ01137359)
 -  Integrate Intruder PL 13.00.05.00 (RO SCGCQ01263844)(SCGCQ01265401)
 -  Add additional sense data to firmware tracker list(SCGCQ01254954)
 -  Method for determining bad ONFI flash via Storcli & SNMP trap upon NAND flash failure for Aspen and Vail (Invader and Intrude(SCGCQ01219862)
 -  MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 -  MPI 2.6: Add Aero PCI Device IDs(SCGCQ01373008)
 -  Isolating faulty cable issue from bad drive issue(SCGCQ01215270)
 -  PL integration(SCGCQ01268896)
CSETActivities:
 -  MR7.1_NVMe: After foreign import of 64 R0 VDs, operating system unable to discover the VDs(SCGCQ01229929 Port Of SCGCQ01209394)
 -  FW crashes when FW update(OFU) is done with faluty onfi(SCGCQ01235056 Port Of SCGCQ01227115)
 -  Server (Purley): Controller (16i) (SCGCQ01235753 Port Of SCGCQ01200311)
 -  In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01237142 Port Of SCGCQ01213915)
 -  Storcli failed to stop drives LED locating with a range(SCGCQ01241870 Port Of SCGCQ01051728)
 -  MR7.1_NVMe: After foreign import of 64 R0 VDs, operating system unable to discover the VDs(SCGCQ01242766 Port Of SCGCQ01209394)
 -  unable to encrypt disk when using no pass(SCGCQ01245596 Port Of SCGCQ01144752)
 -  Offline Marked DG (RAID0) appearing in RHEL 7 install(SCGCQ01245782 Port Of SCGCQ00995384)
 -  SAS2208 card reset in DataCenter due to unknown reason(SCGCQ01247264 Port Of SCGCQ01240574)
 -  RDM in Use(SCGCQ01255837)
 -  ONFI: To properly handle the OCR case with RESET Status Register.(SCGCQ01259337 Port Of SCGCQ00665475)
 -  ONFI BBLIST:ONFI BadBlocks: COL disarmed, VDs remain in WB mode, no Administrative Messages to bad flash part.(SCGCQ01260470 Port Of SCGCQ01235856)
 -  Firmware halts upon changing controller personality to JBOD mode with MCTP enabled(SCGCQ01260889 Port Of SCGCQ01252243)
 -  Infinite loop in onfiSyncModeEnter(SCGCQ01260995 Port Of SCGCQ00329024)
 -  FW crashes when setting fwtermlog bbu=on to a card with bad NAND flash(SCGCQ01261425 Port Of SCGCQ01129530)
 -  Insertion of the boot messages and the evets for montoring the ONFI backup capacity.(SCGCQ01263212 Port Of SCGCQ00433463)
 -  'C0:mr_wakeup: mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors.(SCGCQ01263800 Port Of SCGCQ01256120)
 -  Handling of DCR errors in MSS core(SCGCQ01263859 Port Of SCGCQ01263110)
 -  Invalid date for next learn cycle is set due to invalid date from OEM server (STF: Next learn time is 1970(SCGCQ01264476 Port Of SCGCQ01152321)
 -  GetAllLDAllowedOperation call in Storelib is not returning Allowed operations when some LDs are deleted(SCGCQ01265445 Port Of SCGCQ01250559)
 -  FD33xD issues in VMWare(SCGCQ01266300 Port Of SCGCQ01203008)
 -  In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01274496 Port Of SCGCQ01213915)
 -  MR_6.13:FW flash pack (SCGCQ01280567 Port Of SCGCQ01273216)
 -  unable to encrypt disk when using no pass(SCGCQ01287082 Port Of SCGCQ01144752)
 -  Controller cache discarded due to memory/battery problem(SCGCQ01288848 Port Of SCGCQ01280181)
 -  RAID10 VD goes to failed state after performing RLM(SCGCQ01289123 Port Of SCGCQ01277951)
 -  IN FAILED ARRAY bit is not being set when a VD is cleared(SCGCQ01289194 Port Of SCGCQ01137359)
 -  Storcli Failed to create single PD R0 from UGood drive which has replaced a UBAD foreign drive(SCGCQ01290418 Port Of SCGCQ01282181)
 -  RAID10 VD goes to failed state after performing RLM(SCGCQ01291340 Port Of SCGCQ01277951)
 -  Controller cache discarded due to memory/battery problem(SCGCQ01291492 Port Of SCGCQ01280181)
 -  Cannot stop patrol read on PD with medium errors by the stop cmd(SCGCQ01294884 Port Of SCGCQ01063103)
 -  Perf(SCGCQ01297497 Port Of SCGCQ01283507)
 -  Code review: turn off the onfi when bbu is bad(SCGCQ01297666 Port Of SCGCQ01297565)
 -  Code review: turn off the onfi when bbu is bad(SCGCQ01299260 Port Of SCGCQ01297565)
 -  Perf(SCGCQ01300759 Port Of SCGCQ01283507)
 -  PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01304919 Port Of SCGCQ01288781)
 -  Firmware:(SCGCQ01306491 Port Of SCGCQ01258853)
 -  6.14 : To fix IOPATH overflow during linking(SCGCQ01311731 Port Of SCGCQ01311464)
 -  Unable to access device PD (SSD)(SCGCQ01321307 Port Of SCGCQ01268412)
 -  OS hung and iMR FW reset when do delete and create VD from previous powersave PD (Spindowned)(SCGCQ01326069 Port Of SCGCQ01287286)
 -  HW workaround implementation for SCGCQ00830272 and SCGCQ01048567(SCGCQ01326394 Port Of SCGCQ01323607)
 -  B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B)(SCGCQ01331892 Port Of SCGCQ01271186)
 -  B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B)(SCGCQ01332726 Port Of SCGCQ01271186)
 -  MR 6.14 Intruder(Vail): Intruder Controller hangs in primary core on reboot in Dell Power Edge T620 server.(SCGCQ01334334 Port Of SCGCQ01299482)
 -  MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address(SCGCQ01334365 Port Of SCGCQ01332947)
 -  MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations(SCGCQ01339330 Port Of SCGCQ01332706)
 -  Cache data lost event seen for WT vds(SCGCQ01349420 Port Of SCGCQ01313607)
 -  Kill adapater observed while running IO's on 240 Volumes(SCGCQ01350347 Port Of SCGCQ01313950)
 -  No amber LED when a configured disk is removedPage 3 / 42(SCGCQ01350771 Port Of SCGCQ01343017)
 -  Firmware hits montask while reconstruction when drive is pulled out(SCGCQ01351442 Port Of SCGCQ01260340)
 -  MR 6.13: Blocked Spin down Pass thru command for configured drives.(SCGCQ01351559 Port Of SCGCQ01201958)
 -  IOMMU fault at address 0x80360000(SCGCQ01356192 Port Of SCGCQ01279547)
 -  LSA hangs when user try to change drive security key.(SCGCQ01367331 Port Of SCGCQ01342655)
 -  Invalid date for next learn cycle is set due to invalid date from OEM server (STF: Next learn time is 1970(SCGCQ01241869 Port Of SCGCQ01152321)
 -  MR6.12 NVRAM Overflow (SCGCQ01248969 Port Of SCGCQ01230749)
 -  FD33xD issues in VMWare(SCGCQ01261095 Port Of SCGCQ01203008)
 -  FD33xD issues in VMWare(SCGCQ01263759 Port Of SCGCQ01203008)
 -  Configuration lost and system crashed on having a stale configuration connected(SCGCQ01273187 Port Of SCGCQ01170701)
 -  PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01304921 Port Of SCGCQ01288781)
 -  FC: 0 CS: 0 offload meta signature not valid, ffffffff observed in FW logs on a system restart.(SCGCQ01351052 Port Of SCGCQ01299424)
 -  Controller fails to boot up when migrated from 6.13 to 6.14 FW for Specific OEM(SCGCQ01351614)
 -  SAS2208 card reset in DataCenter due to unknown reason(SCGCQ01311439 Port Of SCGCQ01240574)
 -  Drive Strength values are incorrect for last 8 phys of Red Brick Controller(SCGCQ01247082 Port Of SCGCQ01241680)
 -  Firmware hits montask while reconstruction when drive is pulled out(SCGCQ01282285 Port Of SCGCQ01260340)
 -  Code review: turn off the onfi when bbu is bad(SCGCQ01299219 Port Of SCGCQ01297565)
 -  Controller does not boot up while performing cache offload .(SCGCQ01288845 Port Of SCGCQ01278480)


Version 24.16.0-0101 - High Impact/High Probability of Occurrence
-------------------
FW Package: 24.16.0-0101
HII: E3.21.14.03
UEFI Driver: 0x06150501
BIOS: 6.32.02.1
iMR FW: 4.660.01-8215

Fixes:
- Fixed an issue where some log context in UART was missing in TTY dump. (SCGCQ01230749)
- Fixed an issuer kill adapter command was executed in line 1272 in file ../../raid/1078dma.c after pulling enclosure cable with IOs running on 240VD, JBOD SCGCQ00857533
- Fixed an issue where cache data could be lost when term log is set to "on." (SCGCQ01267851 Port of - SCGCQ01261426)
- Fixed an issue where CRC mismatch and invalid log event found while querying for Controller properties and learn cycle in parallel. (SCGCQ01219985 Port of Defect - SCGCQ00919945)
- Fixed an issue where rebuild error on PD with iMR 9341-8i SAS3008. (SCGCQ01220128 Port of - SCGCQ00915417)
- Fixed an issue where drives were not marked as Foreign upon OCR when controller already has max configured PD's (SCGCQ01219897 Port of Defect - SCGCQ01163849)
- Fixed an issue where drives with configuration were getting converted to JBOD if system already has maximum configurable drives. (SCGCQ01149764 Port of Defect SCGCQ01136693)
- Fixed an issue where StorCLI failed to create single PD R0 from unconfigured good drive which has replaced a UBAD foreign drive. (SCGCQ01290418 Port of Defect SCGCQ01282181)
- Fixed an issue where RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non-240 VD environment. (SCGCQ01267801 Port of Defect SCGCQ01213915)
- Fixed an issue where StorCLI was not showing virtual drives after personality switch from SDS to RAID. (SCGCQ01238639 Port of Defect - SCGCQ01081305)
- Fixed an issue where the controller became unresponsive after hitting OCM error. (SCGCQ01219901 Port of Defect - SCGCQ00924986)
- Fixed an issue where the firmware halts upon changing controller personality to JBOD mode with MCTP enabled. (SCGCQ01260889 Port of Defect SCGCQ01252243)
- Fixed an issue where firmware logs printed in UART were missing in tty dump. (SCGCQ01230749)
- Fixed an issue where OS hung and iMR FW reset when delete and create VD commands using previous powersave physical drive spindowned. (SCGCQ01287286)
- Fixed an issue where StorCLI was not showing virtual drives after personality switch from SDS to RAID. (SCGCQ01093890 PORT OF Defect - SCGCQ01081305)
- Fixed PCI device page enclosure level/connector name to match SAS device page. (SCGCQ01071374)
- Fixed an issue where mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors. (SCGCQ01266169, SCGCQ01256120)
- Fixed an issue where local storage admin config FSM failure on setting TR on 64 VDs, when there were a large number of events transferred over OOB, one event could be missing in some cases. (SCGCQ01243832, SCGCQ01243833, SCGCQ01243834, SCGCQ01243836 PORT OF Defect SCGCQ01128180)
- Fixed an issue where some logs printed in UART were missing in TTY dump. (SCGCQ01242651, SCGCQ01242650, SCGCQ01242649 PORT OF Defect SCGCQ01230749)
- Fixed an issue where firmware breaks MonTask: line 245 in file ../../raid/1078int.c with IOs on max VD configured and BGOps. (SCGCQ00895481, SCGCQ00895482, SCGCQ00895474 Defect SCGCQ00890133)
- Fixed an issue where as part of R1 undergoing RLM to a R0 volume, the medium errors that were injected, were discovered but not reported as corrected. (SCGCQ00893669 PORT OF Defect -SCGCQ00846621)
- Fixed an issue where iEEESGL flag was not getting set for IO request in SES DCDB handler. (SCGCQ01186523, SCGCQ01238262, SCGCQ01242590, SCGCQ01242592, SCGCQ01242597 PORT OF Defect - SCGCQ01157072)

Enhancements:
- Added defines for SAS 4 and PCIe 4 speeds. (SCGCQ00948955)
- Modified PCIe Link config pages to include a link field. (SCGCQ00954619)
- MR API bit to indicate if the profile is NVMe Only profile. (SCGCQ01213092)
- Fixed an issue where the foreign configuration that has been imported went off-line within few seconds, as all the drives are getting transitioned to Unconfigured-Good with PD_InsertionPostProcess() getting kicked-in. (SCGCQ01198744 Port of Defect SCGCQ00800589)
 - Added two new MFI_STAT values to better describe RAID 10 volume creation errors:  MFI_STAT_INVALID_DRIVE_COUNT and MFI_STAT_UNEVEN_SPAN_NOT_SUPPORTED. (SCGCQ01222698)
- Isolated faulty cable issue from bad drive issue. (SCGCQ01203751)
- Removed all defines and structure fields related to SOP support. (SCGCQ00925839)
- Removed all defines and structure fields related to AHCI support. (SCGCQ00948258)
- Added EclosureLevel and ConnectorName fields to PCIe Device Page 0 with the same meaning as SAS Device Page 0. (SCGCQ00949638)
- Added IOCException bit 10 to indicate that backend PCIe device support has been disabled due to an initialization failure and
added InitStatus field to PCIe IO Unit Page 1 t provide more detail.(SCGCQ01009104)
- Added flag to force completion queue entry return for NVMe Encapsulated request. (SCGCQ01013930)
- Added Negotiated Link Rate and Negotiated Port Width to PCIe Device page 0. (SCGCQ01017027)
- Added bit to LinkFlag field of PCIe IO Unit Page 1 PhyData to specify SRIS mode. (SCGCQ01018687)
- Updated header file to include SATADeviceWait time to IO Unit page 11. (SCGCQ01092340)
- Added new definitions for the ImageType field of FwDownload and FwUpload messages. Also, added new flash region definitions for the Flash Layout Extended Image Data. (SCGCQ01136127)
- Added reason codes MPI26_EVENT_ACTIVE_CABLE_PRESENT and MPI26_EVENT_ACTIVE_CABLE_DEGRADED to Active Cable Exception Event Data. (SCGCQ01146583)
- Defined interface to support firmware assisted VD/JBOD properties:  max IO size, device queue depth. (SCGCQ01188711)
- Fixed an issue where L2/L3 Cache error was detected on the RAID controller during boot (24 hours after shutdown hang. (SCGCQ01219839 Enhancement Request SCGCQ01018958)

Version 24.16.0-0092 - High Impact/High Probability of Occurrence
-------------------
FW PACKAGE: 24.16.0-0092
MR FW:  4.660.00-8156
iMR FW:  4.660.01-8157
BIOS:  6.32.02.1
UEFI:  0x06150501
HII:  03.21.14.01

Fixes:
 - Fixed an issue where MR_RAID_CTX_G35 reserved field has one bit too many, resulting in 17 bits in a U16 - (SCGCQ00886417)
 - Fixed an issue where controller may hang when an OCR is triggered on a RAID5 LD with no supercap - (SCGCQ00926628)
 - Fixed an issue where PDs are getting swapped and rebuild starts on incorrect PD after an enclosure power cycle - (SCGCQ00927155)
 - Worked around an issue where a false ReplyParityError may occur - (SCGCQ00927504)
 - Fixed an issue where numSGEExt field was removed from MPI25_SCSI_VENDOR_REGION, affecting support for 1MB IO - (SCGCQ00927738)
 - Fixed an issue where CacheVault size reports as 0KB for some controllers - (SCGCQ00929077)
 - Fixed an issue where controller firmware may halt with error "MonTask: line 1281 in file ../../raid/1078dma.c" - (SCGCQ00931397)
 - Fixed an issue where ONFI hardware was disarmed on OCR - (SCGCQ00933096)
 - Fixed an issue where MSM does not show "hide" option after "unhide" on RAID0 - (SCGCQ00933123)
 - Fixed an issue where rebuild doesn't complete with cmd_block_flush on RAID6 with SAS SSD - (SCGCQ00933841)
 - Fixed an issue where storcli is unable to create logical drives via auto-configuration, such as with command "storcli /cx set autopdcache=r0" - (SCGCQ00935727)
 - Fixed an issue where a new field in RAID_MAP_EXT causes backward compatibility issues - (SCGCQ00940224)
 - Fixed an issue where online firmware update may fail in Windows due to language attribute - (SCGCQ00941886)
 - Fixed an issue where performance was lower than expected due to DataCacheInvalidateSnoop was not being used for sense buffer- (SCGCQ00944526)
 - Fixed an issue where makefile is missing changes required for enabling PLDEBUG - (SCGCQ00945858)
 - Fixed an issue where performance was lower than expected due to stale calls to processdevicewaitQ - (SCGCQ00947221)
 - Fixed an issue where code events had repetitive IDs - (SCGCQ00948535)
 - Fixed an issue where a value assigned to a variable is never used - (SCGCQ00948781)
 - Fixed an issue where error "MonTask: line 245 ..1078int.c" may occur on reboot with foreign import - (SCGCQ00948931)
 - Fixed an issue where two enclosure IDs are displayed in MSM Physical tab when connected via multipath to some enclosures - (SCGCQ00950425)
 - Fixed an issue where firmware fails to copyback from hotspares - (SCGCQ00952836)
 - Fixed an issue where inquiry string is not updated during drive firmware upgrade through offline mode update - (SCGCQ00953396)
 - Fixed an issue where code analysis tool reported issues - (SCGCQ00954107)
 - Fixed an issue where firmware may hang on enclosure power cycle - (SCGCQ00976597)
 - Fixed an issue where error "MonTask: line 1281 in file ../../raid/1078dma.c" may occur on enclosure power cycle - (SCGCQ00976780)
 - Fixed an issue where CacheCade firmware may not get enough time to flush windows when no free window is available - (SCGCQ00976904)
 - Fixed an issue where ring buffer print was occurring even when PLDEBUG is not enabled - (SCGCQ00979831)
 - Fixed an issue where controller firmware may halt at "MonTask:" when running IO to CacheCade Virtual Drives - (SCGCQ00980216)
 - Fixed an issue where controller firmware may halt at "MonTask:" during enclosure power cycle - (SCGCQ00981645)
 - Fixed an issue where DATATLB error may occur on hotplug of some enclosures - (SCGCQ00983232)
 - Fixed an issue where controller firmware may halt when running SAS adapter diagnostic command from storcli - (SCGCQ00987879)
 - Fixed an issue with some unused values in code - (SCGCQ00987940)
 - Fixed some issues discovered in code review - (SCGCQ00987966)
 - Fixed an issue where error "MonTask: line 909 in file ../../raid/raidscsi.c" may occur during heavy IO and power cycles - (SCGCQ00988674)
 - Fixed an issue where data length may not be set appropriately based on CBD size - (SCGCQ00988813)
 - Fixed an issue where storclio may fail to read some VPD information from SBR - (SCGCQ01065177, Port of SCGCQ00990939)
 - Fixed an issue where OCR is not enabled by default in release candidate builds - (SCGCQ00991489)
 - Fixed an issue where a performance issue may occur - 9% drops for 6Gig 512BSATASSDs with 24PD R5 in RW 32KB IOSz for 256QD - (SCGCQ00991492)
 - Fixed an issue where kill adapter may occur when restoring multipath with SATA drives - (SCGCQ00992114)
 - Fixed an issue where an uninitialized byte transfer variable may cause unaligned DMA lengths - (SCGCQ00994097)
 - Fixed an issue where controller firmware may fault when importing a configuration with only Global Hotspare PDs on an iMR controller - (SCGCQ00994846)
 - Fixed an issue where controller firmware may hang on abort of Background Initialization of a VD expansion - (SCGCQ00996532)
 - Fixed an issue where pinned cache data structure members may need to be reinitialized between firmwares with different cache header versions - (SCGCQ00996607)
 - Fixed an issue where enclosure discovery may fail when enclosure with spun-down drives is disconnected and reconnected - (SCGCQ00996692)
 - Fixed an issue where error "IO error 9 in CheckFwIoDescList" may occur on cable pull/push - (SCGCQ00997291)
 - Fixed an issue where CPU affinity define values may not be updated properly to align with CPU affinity structure changes - (SCGCQ01000077)
 - Fixed an issue where DCMD processing may return before setting the JBOD as a boot device in NVRAM - (SCGCQ01000230)
 - Fixed an issue where OCR may not be blocked after firmware downgrade - (SCGCQ01000359)
 - Fixed an issue where SAS SSD RAID5 performance may be lower than expected - (SCGCQ01001861)
 - Fixed an issue where CtrlInfo.adapterOperations3.supportProfileChange is missing in API- (SCGCQ01001936, SCGCQ01014835)
 - Fixed an issue where number of LDs may not be checked before calling RM_SataBBMUpdateDivertNodesFromSBBMTable - (SCGCQ01002055)
 - Fixed an issue where CacheCade Virtual Drive deletion path refers to the wrong Virtual Drive - (SCGCQ01002268)
 - Fixed an issue where controller firmware may hang after connecting some enclosures with SATA drives - (SCGCQ01002798)
 - Fixed an issue where error "MonTask: line 1281 in file ../../raid/1078dma.c" may occur when cables are removed/reinserted in a multipath environment with IO - (SCGCQ01002921)
 - Fixed an issue where some changes were not ported - (SCGCQ01003552)
 - Fixed an issue where controller may experience assertion failure when drives are being removed/reinserted with background IO - (SCGCQ01004144)
 - Fixed an issue where DRAM signature may receive a stale copy on ONFI restore - (SCGCQ01004279)
 - Fixed an issue where firmware switches descriptors and prepares for an offload even when SuperCap is absent - (SCGCQ01004385)
 - Fixed an issue where performance may be lower than expected for Sequential Reads in RAID mode - (SCGCQ01012499)
 - Fixed an issue where error "MonTask@line 179 in file ../../dm/src/chipmgr.c" may occur on repeated system reboots - (SCGCQ01015019)
 - Fixed an issue where CacheCade parameters are populated in controller info even when 240VD feature is enabled - (SCGCQ01015026)
 - Fixed an issue where SAS Port PAge 0 and SAS IO UNIT Page 1 did not function correctly resulting in MonTask error - (SCGCQ01015470)
 - Fixed an issue where controller firmware may throw invalid arguments when setting debug variable for some commands - (SCGCQ01015761)
 - Fixed an issue where controller firmware may exhibit MonTask error when setting up debug variables with levels from storcli - (SCGCQ01016534)
 - Fixed an issue where controller firmware perform cache offload and restore operation even on a clean shutdown - (SCGCQ01018477)
 - Fixed an issue where SDS personality was not supporting 1MB IO - (SCGCQ01020626)
 - Fixed an issue where SDS personality did not have SAS drive queue depth of 128- (SCGCQ01020631)
 - Fixed an issue where divert locks were not being used for Write-Back volumes on Sequential Read - (SCGCQ01020634)
 - Fixed an issue where error "Core 0 in 245 in file ../../raid/1078int.c" may occur on cable remove/reinsert on JBODs with IO - (SCGCQ01020979)
 - Fixed an issue where firmware may incorrectly disable the cache offload engine after an OCR when pinned cache is present and a clean shutdown occurs  - (SCGCQ01021488)
 - Fixed an issue where a DATATLB error may occur after flashing controller firmware and rebooting - (SCGCQ01023585)
 - Fixed an issue where controller firmware may halt when controller firmware update occurs immediately after a drive microcode update - (SCGCQ01024661)
 - Fixed an issue where error "Line 245 in ../../raid/1078int.c" may occur when rebooting server after inserting Virtual Drives when pinned cache is present - (SCGCQ01028404)
 - Fixed an issue where write policy may not be retained after unblocking the SDVs and making the CacheCade Virtual Drive / SVD Optimal - (SCGCQ01028464)
 - Fixed an issue where a MonTask error may occur when an SVD is associated with CacheCade and one of the SVD member drives is removed - (SCGCQ01030089)
 - Fixed an issue where unsupported message types in MCTP path were not handled correctly - (SCGCQ01030166)
 - Fixed an issue where an L2 Cache Error may occur when performing cable remove/reinsert on an enclosure - (SCGCQ01030408)
 - Fixed an issue where TweakIO was not supported on iMR - (SCGCQ01032429)
 - Fixed an issue where a cache restore operation may take more than 90 seconds when power cycles occur with pinned cache present - (SCGCQ01033348)
 - Fixed an issue where error "line 1279 in file ../../raid/1078dma.c" with PL fault - (SCGCQ01033740)
 - Fixed an issue where a Pinned Cache critical message may occur when booting from S3 sleep mode - (SCGCQ01033930)
 - Fixed an issue where error "line 4839 in file ../../raid/cache.c" may occur with cache offload - (SCGCQ01034706)
 - Fixed an issue where more than one special task could run on a CacheCade Virtual Drive - (SCGCQ01034955)
 - Fixed an issue where recheck for presence of pinned cache may not occur after command block grant - (SCGCQ01034977)
 - Fixed a timing issue by removing previous change SCGCQ01023287 - (SCGCQ01035343)
 - Fixed an issue where Virtual Drive creation may fail in RAID mode on personality change - (SCGCQ01036091)
 - Fixed an issue where controller firmware may fault with error "line 1279 in file 1078dma.c" - (SCGCQ01036154)
 - Fixed an issue where a kill adapter may be issued when a TUR is sent to a device after IO timeouts - (SCGCQ01037095)
 - Fixed an issue where controller firmware may fault when multipath is broken during IO - (SCGCQ01037747)
 - Fixed an issue where EPDs may not be created after system reboot - (SCGCQ01038702)
 - Fixed an issue where IO to JBOD may fail on some drives when a path is broken in a multipath scenario - (SCGCQ01038719)
 - Fixed an issue where controller firmware may hang during an OCR when a reconstruction from RAID0 to RAID1 is in progress - (SCGCQ01039732)
 - Fixed an issue where a read from an uninitialized pointer may occur - (SCGCQ01040543)
 - Fixed some issues discovered as part of code review - (SCGCQ01040575)
 - Fixed an issue where controller firmware may fault with error "MonTask: line 605 in file ../../raid/routines.c" when controller firmware update and drive firmware updates are performed simultaneously - (SCGCQ01040587)
 - Fixed an issue where error "Assertion failure in ../../raid/cmd.c line 3089" may occur if host task management completes before pending commands are aborted or completed - (SCGCQ01040595)
 - Fixed an issue where pinned cache may result in an assertion failure - (SCGCQ01041463)
 - Fixed an issue where some error cases may not be handled properly - (SCGCQ01041729)
 - Fixed an issue where abort task management function failes to abort firmware commands split into multiple internal commands - (SCGCQ01042128)
 - Fixed an issue where a kill adapter may occur when disableErrorRecovery=1 and a DCMD is sent - (SCGCQ01042237)
 - Fixed a compilation issue - (SCGCQ01042829)
 - Fixed an issue where HII menu may not allow mode change - (SCGCQ01046130)
 - Fixed issues discovered as part of code review - (SCGCQ01047319)
 - Fixed an issue where error "MonTask: line 1280 in file ../../raid/1078dma.c" may occur when toggling SSD caching on/off during IO - (SCGCQ01048675)
 - Fixed an issue where random performance may drop from 1.1M to 0.8M with SAS SSD - (SCGCQ01049230)
 - Fixed an issue where supportBit functionality was not present for MR_CFG_USER_CONFIGURABLE - (SCGCQ01049236)
 - Fixed an issue where cache bypass may not work with 4k drives and a random workload - (SCGCQ01049253)
 - Fixed an issue where PLDEBUG was not disabled - (SCGCQ01049262)
 - Fixed an issue where code may try to access 255th Logical Drive when only 240 are supported - (SCGCQ01049335)
 - Fixed an issue where makeSystem bit in MR_PD_ALLOWED_OPS was not disabled - (SCGCQ01050314)
 - Fixed an issue where alternate path cleanup on device removal may not occur correctly - (SCGCQ01052105)
 - Fixed an issue where JBOD behavior may automatically change to EPD - (SCGCQ01053601)
 - Fixed an issue where EPD may be deleted after a controller OCR - (SCGCQ01054436)
 - Fixed an issue where CacheCade Virtual Drive performance was lower than expected - (SCGCQ01055907)
 - Fixed an issue where MonTask error may occur on firmware upgrade - (SCGCQ01056349)
 - Fixed an issue where error "DATA TLB ERROR(SRR0/1,ESR) exception: sf=c0137f50" may occur under IO to VDs and EPDs in EPD mode - (SCGCQ01057471)
 - Fixed an issue where error handling may not occur for direct attached devices during targetID allocation - (SCGCQ01058026)
 - Fixed an issue where SAS Address for paths may not be shown in firmware events when true multipath is enabled - (SCGCQ01058118)
 - Fixed an issue where firmware flash with OCR may result in "Host memory not available" - (SCGCQ01059104)
 - Fixed an issue where OCR was allowed in Safe Mode - (SCGCQ01059795)
 - Fixed an issue where MonTask error may occur when IO is underway during SVD CacheCade association process - (SCGCQ01060661)
 - Fixed an issue where MonTask DATATLB error may occur on IO timeout with immediate IO - (SCGCQ01061150)
 - Fixed an issue where Virtual Drives may be displayed as 0.000TB after doing a factory reset - (SCGCQ01061594)
 - Fixed an issue where rebuild may not recover properly on medium errors - (SCGCQ01063920)
 - Fixed an issue where an EPD may become Foreign on EPD removal/reinsertion - (SCGCQ01064307)
 - Fixed an issue where an incorrect message may be displayed in EPD mode when no Virtual Drives are present - (SCGCQ01064584)
 - Fixed an issue where firmware may report failure when initiating an Instant Secure Erase against Foreign drives that are Locked - (SCGCQ01064725)
 - Fixed an issue where enclosure topology may change after deleting EPD/JBOD - (SCGCQ01066150)
 - Fixed an issue where drive slot information may not be shown properly, or always shows as 0-3:1:0 - (SCGCQ01066199)
 - Fixed an issue where firmware may allow a reconstruction from RAID0 to RAID6 on iMR - (SCGCQ01066211)
 - Fixed an issue where enclosure topology information may not be cleared from NVRAM - (SCGCQ01069328)
 - Fixed an issue where firmware may throw an event with "Pass-through EPD" instead of "JBOD" - (SCGCQ01070146)
 - Fixed an issue where error "DATA TLB ERROR(SRR0/1,ESR) exception: sf=c0137f50" may occur - (SCGCQ01070174)
 - Fixed an issue where controller firmware may fail to discover a directly-attached SSD - (SCGCQ01073684)
 - Fixed an issue where DDF may be read when the drive is locked by a third-party application - (SCGCQ01074264)
 - Fixed an issue where IO stalls may be seen when Foreign Drives are imported while Pinned Cache is present - (SCGCQ01074390)
 - Fixed an issue where controller firmware may fault with no cache metadata while running heavy IO - (SCGCQ01075043)
 - Fixed an issue where debug routines were not as robust as possible - (SCGCQ01075835)
 - Fixed an issue where a DATATLB error may occur on import of a Foreign Configuration - (SCGCQ01077584)
 - Fixed an issue where JBOD may show up as a RAID0 in 240VD configuration - (SCGCQ01077659)
 - Fixed compiling issues for iMR - (SCGCQ01077981)
 - Fixed an issue where controller firmware may issue kill adapter when power cycling a secondary enclosure repeatedly - (SCGCQ01078220)
 - Fixed an issue where error "FW Crash at line 2001 in file /bbu/onfi.c" may occur when running IO on Virtual Drives when a CacheCade Virtual Drive is present - (SCGCQ01080073)
 - Fixed an issue where controller cannot set personality behavior after flashing firmware - (SCGCQ01080529)
 - Fixed an issue where storcli not showing Virtual Drive after controller personality switch - (SCGCQ01081305)
 - Fixed an issue where controller was not properly determining if a drive needs to be locked - (SCGCQ01083145)
 - Fixed an issue where activity LED is always on even when no drives are present - (SCGCQ01083581)
 - Fixed an issue where L2 Cache Error occurs when IO is run with cable remove/reinsert - (SCGCQ01087818)
 - Fixed an issue where error "MonTask: line 3169 in file mptrec.c" may occur on cable remove/reinsert- (SCGCQ01089223)
 - Fixed an issue where Phase 12 physical layer was not  - Integrated - (SCGCQ01089372)
 - Fixed an issue where EPDs auto configuration fails during OCR on 240VD setup when Pinned Cache is present - (SCGCQ01096547)
 - Fixed an issue where a Physical Layer fault may occur when running IO on SVD when a CacheCade Virtual Drive is present a target resets are issued to Secure JBOD - (SCGCQ01117179)
 - Fixed an issue where controller firmware did not have enough descriptors for 2-die chips - (SCGCQ01118693)
 - Fixed an issue where an ECC error spike may be observed during a Cache Restore operation when read eye training has failed - (SCGCQ01124194)
 - Fixed an issue where compilation broke due to increase in iopath size by 1120 bytes - (SCGCQ01126393)
 - Fixed an issue where a DATATLB error may be observed when IO, target resets, OCR and a rebuild occur concurrently - (SCGCQ01130939)
 - Fixed an issue where controller firmware event logs show EPD creation when booted in JBOD mode - (SCGCQ01130979)
 - Fixed an issue where a kill adapter may occur when moving a PI-enabled RAID5 Virtual Drive to degraded state - (SCGCQ01131151)
 - Fixed an issue where retry mechanism for Cache Offload may run when ECC errors is less than 40 - (SCGCQ01131808)
 - Fixed an issue where Write Back volumes may not be imported when changing controller personality - (SCGCQ01135382)
 - Fixed an issue where controller firmware may disable Fast Path for SED/FDE JBOD - (SCGCQ01135893)
 - Fixed an issue where SES topology information may not be updated as expected - (SCGCQ01137834)
 - Fixed an issue where UEFI driver may not load - (SCGCQ01138961)
 - Fixed an issue where MR_DCMD_CFG_AUTOCFG DCMD is not allowed when ignore64ldRestriction is not set - (SCGCQ01139912)
 - Fixed an issue where some messages in VDM queue may not be initialized with proper values - (SCGCQ01149312)
 - Fixed an issue where a MonTask error may occur when Cache Offload does not complete successfully - (SCGCQ01149971)
 - Fixed an issue where debug code added for testing was not removed - (SCGCQ01152456)
 - Fixed a performance issue where normal IOs were being impacted by inline DMA for double-buffered IO - (SCGCQ01154297)
 - Fixed an issue where controller firmware may use a bad block for Cache Offload operation - (SCGCQ01159064)
 - Fixed an issue where coalescing was enabled for Write-Through EPDs in JBOD personality - (SCGCQ01161309)
 - Fixed an issue where performance may drop 15% SR IO Sizes-4K QD(256),12G SAS HDD,x16 - (SCGCQ01166024)
 - Fixed an issue where performance may drop 12% to 22% SW IO Sizes-16K QD(2) ,12GSAS HDD,x8,x16x,24,x40PD - (SCGCQ01166028)
 - Fixed an issue where a Fatal Firmware error may occur during power cycle  - (SCGCQ01167011)
 - Fixed an issue where performance may drop 20% SR, 8K-IO Size,QD(256) RAID-10 6G SATA-HDD x16DC - (SCGCQ01171907)
 - Fixed an issue where very high write latency may occur - (SCGCQ01176422)
 - Fixed an issue where activity LED may be lit and never turn off - (SCGCQ01191412)
 - Fixed an issue where performance may drop 6% to 15% Perf drop in all IO size with Higher QD in 12G SAS HDD [x16EC,x24EC,x40EC] - (SCGCQ01193231)
 - Fixed an issue where error "MonTask: line 4789 in file ../../raid/cache.c" may occur when importing a RAID0 CacheCade Virtual Drive - (SCGCQ00942270)
 - Fixed some code review defects - (SCGCQ00980759)
 - Fixed an issue where writes may fail on JBODs after an OCR - (SCGCQ00981721)
 - Fixed an issue where host DDF memory is not reserved after OCR followed by firmware flash - (SCGCQ00992541)
 - Fixed an issue where a kill adapter may occur on heavy IO with background operations on CacheCade Virtual Drives and SVD - (SCGCQ00995919)
 - Fixed an issue where controller firmware may asser when JBOD is removed during an OCR - (SCGCQ00996138)
 - Fixed an issue where a suspended rebuild does not start on a RAID1 CacheCade physical drive even after SSCD flush has completed - (SCGCQ00999971)
 - Fixed an issue where error "Montask in line 164 in file ../../raid/2108vDma.c" may occur when scanning for Virtual Drives on directly-attached PI drives - (SCGCQ01000488)
 - Fixed an issue where storcli command "storcli /cx show preservedcache" will report success on an iMR controller - (SCGCQ01002022)
 - Fixed an issue where kill adapter may occur when running 64K IOs on Virtual Drives and JBODs with a mix of 6Gbps and 12Gbps drives - (SCGCQ01023587)
 - Fixed an issue where a drive microcode update start event is not logged when offline method used - (SCGCQ01024062)
 - Fixed an issue where insertion/removal of a secondary SEP or expander device would affect firmware internally maintained enumerated topology order - (SCGCQ01024970)
 - Fixed an issue where controller firmware may hang on power cycle of an enclosure - (SCGCQ01043365, Port of SCGCQ01025024)
 - Fixed an issue where all EPD errors may not return MFI_STAT_SCSI_DONE_WITH_ERROR - (SCGCQ01025697)
 - Fixed an issue where EPDs may be created in DDF_ForeignScan() - (SCGCQ01028289)
 - Fixed a code merge issue - (SCGCQ01029522)
 - Fixed an issue where a DATATLB error "restore_cache_line_buffer +1b0" may occur on enclosure removal while updating drive firmware - (SCGCQ01029529)
 - Fixed an issue where Unavailable flag may not be cleared for VDs even after spin-up recovery - (SCGCQ01030591)
 - Fixed an issue where storcli drive inquiry command may fail when true multipath is enabled - (SCGCQ01033041)
 - Fixed an issue where a DATATLB "DM_PL_ProcessCompletion+334" error may occur while running IO - (SCGCQ01033082)
 - Fixed an issue where controller firmware did not allocate targetID based on the port and slot the JBOD is direct attached to - (SCGCQ01033957)
 - Fixed some code review issues - (SCGCQ01036929)
 - Fixed an issue where backend Physical Layer frames for Core0 were not 4k - (SCGCQ01037133)
 - Fixed an issue where kill adapter may occur when power cycling enclosures - (SCGCQ01037718)
 - Fixed an issue where enclosure enumeration order should remain consistent across OCRs and reboots - (SCGCQ01038595)
 - Fixed an issue where incorrect values may occur in CacheCade Virtual Drive counters - (SCGCQ01039080)
 - Fixed an issue where unsupported message type handling does not occur according to MCTP spec - (SCGCQ01039363)
 - Fixed an issue where controller firmware allows switch from EPD to EPD-passthrough even with more than 128 devices - (SCGCQ01039421)
 - Fixed an issue where a diagnostics test failure moves a Secure JBOD drive to Foreign Unconfigured Good - (SCGCQ01039512)
 - Fixed an issue where controller firmware may crash during hibernation - (SCGCQ01042005)
 - Fixed an issue where ldlimit may not be able to reset to default when Virtual Drives exist with targetID greater than 64 - (SCGCQ01042131)
 - Fixed an issue where storcli may show an incorrect number of Physical Drives - (SCGCQ01042249)
 - Fixed an issue where controller may show port number as "null" or the same even with different types of port connectivity - (SCGCQ01045937)
 - Fixed an issue where an out of bound read and uninitialized scalar variable may occur - (SCGCQ01046119)
 - Fixed an issue where controller cannot create the 240th Virtual Drive even though 240 are supported - (SCGCQ01046644)
 - Fixed some code review issues - (SCGCQ01047222)
 - Fixed an issue where "OOB_slaveOnly" variable may not be set to 0 for PCIe path - (SCGCQ01049035)
 - Fixed an issue where debug prints were not removed in Host Task Management and EPD creation path - (SCGCQ01049304)
 - Fixed some code review issues - (SCGCQ01050889)
 - Fixed an issue where flags indicating SSC flush status may not be cleared even after completion of the SSC flush - (SCGCQ01053360)
 - Fixed an issue where iMR controller restart may fail after firmware flash even though OCR is enabled - (SCGCQ01053769)
 - Fixed some code review issues - (SCGCQ01054547)
 - Fixed an issue where error "Exception in core 0" may occur when running target resets with IO - (SCGCQ01058187)
 - Fixed an issue where controller firmware hangs after destaging preserved cache - (SCGCQ01059184)
 - Fixed an issue where a kill adapter may occur when aborting a Full Initialization on 240 Virtual Drives - (SCGCQ01059439)
 - Fixed an issue where a target reset may be issued on an incorrect device handle in true multipath Write-Back configuration - (SCGCQ01059769)
 - Fixed an issue where error "MonTask: line 2379 in file ../../raid/2108vI2o.c" may occur - (SCGCQ01060599)
 - Fixed an issue where error "FW crash at line 1155 in file ../../dm/src/dm.c" may occur - (SCGCQ01061211)
 - Fixed an issue where error "Controller crash observed at line 1280 in file ../../raid/1078dma.c" when rebuilding a RAID1 - (SCGCQ01062346)
 - Fixed an issue where SSC flush flags may be cleared in a non-command-block context - (SCGCQ01062386)
 - Fixed an issue where storcli may display "Max SGE Count 60" even after largeIOsupport is enabled - (SCGCQ01064082)
 - Fixed an issue where a DATATLB error "firmware break at Line 245 in ../../raid/1078int.c" may occur - (SCGCQ01064652)
 - Fixed an issue where firmware logs may show an incorrect print for Background Initialization start on a RAID0 Virtual Drive after completing a Reconfiguration - (SCGCQ01065567)
 - Fixed an issue where a kill adapter may occur when hotplugging 240 EPDs with IO in progress - (SCGCQ01066104)
 - Fixed an issue where L2 Cache Error may be seen during ref tag error recovery on a PI Virtual Drive - (SCGCQ01066219)
 - Fixed a performance issue where up to ~18% Perf Drop, SW for 4K/8k/16K @ 4&16QD, RW for 8K @ 4 QD, 12G SAS SSD,24PD,R5 - (SCGCQ01067709)
 - Fixed an issue where controller may fail a drive for a SMART error even when MRIE mode is 2 or 3 - (SCGCQ01070758)
 - Fixed an issue where not enough information was included in dump memory to debug memory alloc/free related issues - (SCGCQ01073663)
 - Fixed an issue where controller firmware may halt on Pinned Cache generaion with multiple RAID0 Virtual Drives - (SCGCQ01075170)
 - Fixed an issue where failed FastPath / immediate IO may report as success leading to SCSI-3 PRR failure  - (SCGCQ01076183)
 - Fixed an issue where a DATATLB error may occur when running IO on a max-PD Virtual Drive with Daisy-chained enclosures - (SCGCQ01076235)
 - Fixed an issue where command queue depth only scaling to 64 for SAS HDDs - (SCGCQ01076289)
 - Fixed an issue where multiInitSupport was not in the EepromMfcDisplay debug function - (SCGCQ01079664)
 - Fixed an issue where controller firmware crash may occur when running IO in JBOD mode and multipath is enabled - (SCGCQ01080258)
 - Fixed an issue causing iMR compilation problems - (SCGCQ01081326)
 - Fixed an issue where error "Montask line 121 in file ../../raid/taskman.c" with "No more tasks available!" - (SCGCQ01082101)
 - Fixed an issue where security key may be deleted when switching controller personality - (SCGCQ01085646)
 - Fixed an issue where cache thresholds may not be adjusted appropriately on Pinned Cache generation - (SCGCQ01099559)
 - Fixed an issue where error "Input parameters are invalid" may occur when creating a Virtual Drive in Advanced configuration - (SCGCQ01125119)
 - Fixed an issue where double buffering code was not under an #ifdef for easy switch - (SCGCQ01131004)
 - Fixed a performance issue where 5.5% drop in R10,R0 with 16K IO size SR-4QD with 40PD-12G-4K-SAS-HDD-SS-256K-WB-mode-Win2012-R2 - (SCGCQ01134731)
 - Fixed a performance issue where 15% to 20% drops SW IO Sizes-256K QD(1,2),12G SAS HDD,x16,x24,x40- (SCGCQ01166023)
 - Fixed a performance issue that may occur with Virtual Drives with 4Kn members - (SCGCQ01180459)
 - Fixed a performance issue where RAID10 reads intermittently provide very poor performance - (SCGCQ00930527)
 - Fixed an issue where controllers with 2GB of DRAM may fail to discover drives - (SCGCQ00987952)
 - Fixed an issue where MSM provides "Make EPD" option for Unconfigured Good drives - (SCGCQ00995279)
 - Fixed an issue where a kill adapter may occur under heavy IO in a multipath environment - (SCGCQ01016542)
 - Fixed an issue where error "Assertion failure at line 807 in /raid/cache.c" may occur when running CacheCade Virtual Drive association/deassociation and SVD background operations are in progress - (SCGCQ01018367)
 - Fixed an issue where DMA context switching settings are non-optimal for less than 24 disk expander configurations - (SCGCQ01020635)
 - Fixed an issue where error "Firmware crash@line 108 in file ../../raid/taskman.c" may occur when performing creation/deletion of EPDs - (SCGCQ01023898)
 - Fixed an issue where Unconfigured drives may be marked as Foreign even when no DDF is present - (SCGCQ01023963)
 - Fixed an issue where error "Assertion failure in ../../dm/src/dm.c at line 1054" may occur on enclosure power cycle - (SCGCQ01025328)
 - Fixed an issue where true multipath was not enabled - (SCGCQ01028614)
 - Fixed an issue where enclosure devices at sasLevels greater than 1 were determined as direct attached devices - (SCGCQ01029470)
 - Fixed an issue where exposeMultipath EPD param during behaviour mode change was not handled properly - (SCGCQ01029550)
 - Fixed an issue where controller firmware fails to import Foreign configuration with Pinned Cache - (SCGCQ01029579)
 - Fixed an issue where error "MonTask: line 2357 in file ../../raid/2108vI2o.c" may occur when running IO on 64 Virtual Drives and an Online Controller Reset is performed - (SCGCQ01030234)
 - Fixed an issue where Operating System fails to boot due to continuous Logical Drive write map sync prints - (SCGCQ01030470)
 - Fixed an issue where DDF PdDataInfo structure may be overwritten while a DDF update is in progress - (SCGCQ01030749)
 - Fixed an issue where AutoConfig options set 0 after flashing firmware - (SCGCQ01033250)
 - Fixed an issue where system may hang on boot when a reconstruction is in progress - (SCGCQ01034677)
 - Fixed an issue where more than one reconstruction at a time may be allowed - (SCGCQ01036076)
 - Fixed an issue where JBOD or EPD-passthrough may not be able to be created from Unconfigured drives when behavior mode is JBOD - (SCGCQ01039737)
 - Fixed an issue where applications may fail CacheCade Virtual Drive creation when controller booted in 240VD mode is switched to 64VD mode - (SCGCQ01040017)
 - Fixed an issue where Virtual Drive policies may not revert back on downgrade failure due to error "MFI_STAT_FLASH_NOT_ALLOWED" - (SCGCQ01041187)
 - Fixed an issue where error "Montask line 1279 in file ../../raid/1078dma.c" may occur on performing target resets while running IO to Virtual Drives and JBODs - (SCGCQ01041735)
 - Fixed an issue where Clear Foreign Configuration and Clear Configuration may report success even on failure - (SCGCQ01042004)
 - Fixed some compilation issues - (SCGCQ01042472)
 - Fixed an issue where defaults may be set on reboot after changing MFC settings - (SCGCQ01045951)
 - Fixed an issue where boot drive setting may change to the first Virtual Drive by default on every reboot - (SCGCQ01045976)
 - Fixed some code review issues - (SCGCQ01046172)
 - Fixed an issue where controller firmware may fault during a firmware upgrade - (SCGCQ01051069)
 - Fixed an issue where controller may incorrectly process the device wait queue during host task management - (SCGCQ01053010)
 - Fixed an issue where Mode E offline flashing may display failure even after the image transfer is successful - (SCGCQ01054885)
 - Fixed an issue where a kill adapter may occur when running Background Operations with OCR while CacheCade Virtual Drive association/dissociation in progress - (SCGCQ01058771)
 - Fixed an issue where controller firmware may fault when downgrading - (SCGCQ01058792)
 - Fixed an issue where an L2 Cache Error may be reported during OFC on iMR controllers - (SCGCQ01059873)
 - Fixed an issue where error "Assertion failure in ssd_cache_fw.c" may occur during CacheCade Virtual Drive association/dissociation and Background Operation start/top and secondary enclosure cable insert/remove - (SCGCQ01059919)
 - Fixed an issue where DATATLB error "Fatal firmware error: Line 245 in ../../raid/1078int.c" may occur - (SCGCQ01061565)
 - Fixed an issue where error "MonTask at line 245 in file /raid/1078int.c" may occur when importing a Foreign SED/FDE configuration - (SCGCQ01065547)
 - Fixed an issue where commands may not fail bakc to host if Command Block is not granted for more than 20 seconds - (SCGCQ01066198)
 - Fixed an issue where "C0:MFI_STAT_NOT_FOUND" may be shown in firmware log when running IO against EPD/JBOD and system reboot/shutdown occurs - (SCGCQ01068464)
 - Worked around an issue where spurious interrupts may cause a Physical Layer fault D230 - (SCGCQ01068609)
 - Fixed an issue where a DATATLB error may occur when CacheCade support is not enabled on the system - (SCGCQ01069431)
 - Fixed an issue where controller personality mode remains the same even when it has been changed to single-drive RAID0 - (SCGCQ01074396)
 - Fixed an issue where stale enclosure entries may remain in topology array even after removing an enclosure - (SCGCQ01076184)
 - Fixed an issue where only 30 Physical Drives may be able to be converted to Unconfigured Good on iMR controllers - (SCGCQ01077558)
 - Fixed an issue where controller RAID layer may not handle RDM_STATUS_FAILED error - (SCGCQ01082528)
 - Fixed an issue where cache may not be initialized after the deletion of the last targetID - (SCGCQ01156911)
 - Fixed an issue where controller firmware may fault under heavy IO and target resets in progress with more than 32 EPDs - (SCGCQ01010222)
 - Fixed an issue where controller firmware may fault when marking a Physical Drive of a CacheCade Virtual Drive as missing followed by a Replace Missing operation - (SCGCQ01021539)
 - Fixed an issue where persistent reservation may not occur for true multipath configurations - (SCGCQ01022350)
 - Fixed an issue where an improper offload of MEM_ - Fixed region in DDR may occur on reboot of host with Pinned Cache - (SCGCQ01029481)
 - Fixed an issue where cache windows may not be properly allotted after making a RAID0 CacheCade Virtual Drive offline and then online - (SCGCQ01030735)
 - Fixed an issue where controller firmware may hang on target reset to multiple drives - (SCGCQ01030891)
 - Fixed an issue where the Virtual Drive ID may not be properly allocated when creating 240 Virtual Drives - (SCGCQ01035495)
 - Fixed an issue where pldebug was not enabled - (SCGCQ01037904)
 - Fixed an issue where if and else case were both returning FALSE - (SCGCQ01040437)
 - Fixed an issue where controller firmware may crash when running IO to a dual-core capable Virtual Drive with Pinned Cache present - (SCGCQ01041766)
 - Fixed an issue where an Assertion failure error may occur when Task Management is issued to EPDs with background IO - (SCGCQ01047185)
 - Fixed some code review issues - (SCGCQ01047193)
 - Fixed an issue where load balance may not occur on boot due to outstanding IO in disk - (SCGCQ01050467)
 - Fixed an issue where only 26 drives can be converted as Unconfigured Good - (SCGCQ01059916)
 - Fixed an issue where JBODs may go to Failed state when running Full Initialization with multipath cable push/pull - (SCGCQ01060295)
 - Fixed an issue where incorrect Physical Drive details may be shown in an EPD deletion event - (SCGCQ01061128)
 - Fixed an issue where a "VD missing" message may be displayed at POST after deleting an EPD and rebooting the system - (SCGCQ01061827)
 - Fixed a compilation issue - (SCGCQ01063479)
 - Fixed an issue where an error "kill adapter at line 1280" may occur under IO and multipath cable push/pull under RHEL7 - (SCGCQ01065343)
 - Fixed an issue where controlelr name may not be displayed in any applications - (SCGCQ01069489)
 - Fixed an issue where a DATATLB error may occur on iMR controllers when attempting to enable TTY to see discovery logs - (SCGCQ01078092)
 - Fixed an issue where some controllers may fault with Uncorrectable ECC error detected  - (SCGCQ01080061)
 - Fixed an issue where an incorrect offset to devstateTAble pointers may occur - (SCGCQ01081352)
 - Fixed an issue where an EPD may move to Shield state on SCSI/Immediate IO respose of BUSY - (SCGCQ01095557)
 - Fixed an issue where an error "FW crash at line 8003 in file ../../raid/pd.c" may occur when performing target resets and Background IO - (SCGCQ01100216)
 - Fixed an issue where AutoConfig DCMD may not report the correct stsatus for non-240VD mode - (SCGCQ01156132)
 - Fixed an issue where text4 section may not load during firmware initialization - (SCGCQ01027455)
 - Fixed some code review defects - (SCGCQ01031313)
 - Fixed an issue where DATATLB error may occur when updating controller firmware when offline Disk Groups are present, followed by a server reboot - (SCGCQ01034958)
 - Fixed an issue where error "Assertion failure at line 2359 in file ../../raid/2108vI2o.c" may occur when switching personalities - (SCGCQ01035492)
 - Fixed an issue where error "Exception in Core 0" may occur during reconstruction of SVD when a CacheCade is present - (SCGCQ01037857)
 - Fixed an issue where controller firmware may hang when creating a RAID1 and RAID0 Virtual Drive - (SCGCQ01042209)
 - Fixed an issue where EPDs may be converted to Unconfigured Good when performing enclosure power cycles - (SCGCQ01046038)
 - Fixed an issue where buffer overruns may occur - (SCGCQ01047035)
 - Fixed an issue where values provided for MRIE mode may not be validated properly - (SCGCQ01048239)
 - Fixed an issue where IO failures during path removal in true multipatch may not be handled correctly - (SCGCQ01054654)
 - Fixed an issue where Auto Import of Foreign Configurations may fail for RAID1 Virtual Drive when Pinned Cache is present - (SCGCQ01060671)
 - Fixed an issue where storcli may allow to set link speed to 1.5Gbps even though that is not supported - (SCGCQ01061902)
 - Fixed an issue where a personality switch from EPD to single-drive RAID0 may fail even when there is no configuration - (SCGCQ01065596)
 - Fixed a typo - (SCGCQ01070821)
 - Fixed an issue where controller may hang when flashing a 4MB image - (SCGCQ01157158)
 - Fixed an issue where controller firmware returns success to applications even though a Secure JBOD conversion as failed - (SCGCQ01038757)
 - Fixed an issue where a timer list issue may occur when creating/deleting EPDs on a large config - (SCGCQ01043654)
 - Fixed an issue where error "Failed to get VD VF mapping list" may occur on query "show VF map" - (SCGCQ01064037)
 - Fixed an issue where MonTask error "No More Task available!!" may occur when a task management is issued from the Operating System - (SCGCQ01085194)
 - Fixed an issue where L2/L3 Cache Error may be detected on controller during boot after shutdown - (SCGCQ01018958)
 - Fixed an issue where device discovery may infinite loop when firmware gets a timeout for READ CAPACITY command - (SCGCQ01015624)
 - Fixed an issue where a BSOD may occur on firmware upgrade from non-240VD firmware to 240VD-firmware when OS is behind the controller - (SCGCQ00829978, SCGCQ00829979, SCGCQ00829980, Port of SCGCQ00825725)
 - Fixed an issue where firmware may return incorrect values for Logical Drive Physical Sector Size when Force Emulation is set on a 4Kn drive - (SCGCQ00918755, Port of SCGCQ00905002)
 - Fixed an issue where an exception may occur on import of a Foreign Configuration whe number of Virtual Drives is greater than the supported 31 - (SCGCQ00935533, Port of SCGCQ00927528)
 - Fixed an issue where storcli show all command triggers a datastore disconnect in VMWare ESXi - (SCGCQ00935551, Port of SCGCQ00928506)
 - Fixed an issue where MonTask error may occur on boot after creating 240 Virtual Drives and rebooting the system - (SCGCQ00945341, Port of SCGCQ00905416)
 - Fixed an issue where a kernel panic and/or MonTask error may occur due to host command count being incorrectly updated - (SCGCQ00976812, Port of SCGCQ00948256)
 - Fixed an issue where dirty cache was not being ignored when firmware is updated with cache version change - (SCGCQ00988757, Port of SCGCQ00944012)
 - Fixed an issue where security-related commands run even if a lock key is not assigned to controller  - (SCGCQ00988906, Port of SCGCQ00940921)
 - Fixed an issue where controller firmware may crash when running IO if the FastPath engine tries to add the timer for a new IO - (SCGCQ00988908, SCGCQ01017522, Port of SCGCQ00917821)
 - Worked around an issue where a firmware fault may occur due to a false ReplyParityError - (SCGCQ00988988, SCGCQ00988989, Port of SCGCQ00927504)
 - Fixed an issue where locate LED may remain on for a reinserted drive - (SCGCQ01014122, Port of SCGCQ00998112)
 - Fixed an issue where a DATATLB error may occur when hotplugging some enclosures - (SCGCQ01015796, Port of SCGCQ00983232)
 - Fixed an issue where firmware may hang when trying to complete a FW_RAID_MAP command - (SCGCQ01022257, Port of SCGCQ01015745)
 - Fixed an issue where Abort Task may fail to abort outstanding FastPath command - (SCGCQ01023239, Port of SCGCQ01020088)
 - Fixed an issue where controller may be unable to import Foreign, locked Secured Drives - (SCGCQ01023287, Port of SCGCQ00994721)
 - Fixed an issue where IOs may be terminated on EPDs when doing target resets while disks go Offline - (SCGCQ01028573, Port of SCGCQ00953540)
 - Fixed an issue where initial boot prints may be missing during firmware initialization and restore operations - (SCGCQ01041470, Port of SCGCQ01012327)
 - Fixed an issue where ECC bit count may not be programmed to 24 correctly - (SCGCQ01069986, Port of SCGCQ01051207)
 - Fixed an issue where CTRL-R may not automatically refresh the screen after some operations - (SCGCQ01070182, Port of SCGCQ01068368)
 - Fixed an issue where Spare Pool start address may be set incorrectly after some cache offload and restore operations - (SCGCQ01070258, Port of SCGCQ01069753)
 - Fixed an issue where performance degradation may occur due to MultiCpuAtomicDec()/MultiCpuAtomicInc() functions modifying scsi_pending_cmds - (SCGCQ01073190, Port of SCGCQ01044217)
 - Fixed an issue where Data Protection bit may not be cleared during Secure Erase and reboots - (SCGCQ01078532, SCGCQ01078533, SCGCQ01078536, SCGCQ01069761, Port of SCGCQ01065119)
 - Fixed an issue where a read retry is needed when ECC errors in excess of 24bits per 1100 bytes occur - (SCGCQ01081899, SCGCQ01081900, SCGCQ01089927, Port of SCGCQ01078237)
 - Fixed an issue where LUID may be changed during import of Foreign configuration from non-240VD firmware to 240VD firmware - (SCGCQ01084595, SCGCQ01087947, SCGCQ01163258, SCGCQ01163768, Port of SCGCQ00907658)
 - Fixed an issue where error "15=Fatal firmware error: Line 1972 in ../../raid/flex.c" or "MonTask: line 1972 in file ../../raid/flex.c" may occur on boot when running a rebuild and a reconstruction - (SCGCQ00996655, SCGCQ01088182, SCGCQ00907979, Port of SCGCQ00902755)
 - Fixed an issue where IO failures may be observed on 4Kn Virtual Drives with PI enabled - (SCGCQ01117016, SCGCQ01118907, SCGCQ01129839, SCGCQ01130945, SCGCQ01130999, SCGCQ01131000, SCGCQ01131001, SCGCQ01131002, SCGCQ01131003, Port of SCGCQ01081912)
 - Disable support for PI and do not allow PI to be re-enabled - (SCGCQ01128064, Port of SCGCQ01105478)
 - Fixed an issue where import of a max Foreign Configuration may fail - (SCGCQ01129847, Port of SCGCQ00679180)
 - Fixed an issue where error "bladeErrorIsrTask ChanNum 0 intStatus" may occur when enabling security on controller - (SCGCQ01130922, SCGCQ01130938, Port of SCGCQ01077578)
 - Fixed an issue where presence of pinned cache may not result in a move of all unpinned windows of a degraded CacheCade Virtual Drive to read-only - (SCGCQ01136063, Port of SCGCQ01118285)
 - Fixed an issue where controller firmware may fault when running command "storcli /c0 set termlog=on" - (SCGCQ01139844, Port of SCGCQ01129530)
 - Fixed an issue where CTRL-H was allowing user to enable PI when PI is disabled - (SCGCQ01141456, Port of SCGCQ01139294)
 - Fixed an issue where EPDs may not be created after system reboot when Physical Drive erase is in progress on one or more drives  - (SCGCQ01146473, Port of SCGCQ01144014)
 - Fixed an issue where a kill adapter may occur during a simultaneous rebuild, reconstruction and drive pull - (SCGCQ01149315, Port of SCGCQ01143971)
 - Fixed an issue where configured drives may be converted to JBOD if system already has maximum number of configurable drives - (SCGCQ01149763, Port of SCGCQ01136693)
 - Fixed an issue where controller may report 1MB as IO size regardless of the IO type or mode - (SCGCQ01180170, SCGCQ01180171, Port of SCGCQ01137690)
 - Fixed an issue where iEEESGL flag may not be set for IO requests in SES DCDB handler - (SCGCQ01186523, SCGCQ01205429, Port of SCGCQ01157072)
 - Fixed an issue where Logical Drive to Physical Drive LDA conversion happens using PRL11 for LBAs that have not yet been migrated - (SCGCQ01201996, Port of SCGCQ01186096)
 - Fixed an issue where flash block read timeouts may be observe when flash file system read failures and read eye training failures occur simultaneously - (SCGCQ01229234, Port of SCGCQ01208490)
 - Fixed an issue where MR_DCMD_CFG_AUTOCFG DCMD may be disabled in non-240 VD environment - (SCGCQ01232073, Port of SCGCQ01213915)
 - Fixed an issue where controller firmware may assert when booting with 4K drives - (SCGCQ00935534, Port of SCGCQ00927547)
 - Fixed an issue where Auto RAID0 may fail with 8 enclosures connected - (SCGCQ00938868, Port of SCGCQ00934300)
 - Fixed an issue where code was not detecting crossage of 1 MB page boundary through proper Assert - (SCGCQ00947988, Port of SCGCQ00931010)
 - Fixed an issue where rebuild fails to start on CacheCade virtual drives after successful import - (SCGCQ00954124, Port of SCGCQ00950030)
 - Fixed an issue where am rebuild error "Error f0" may occur on iMR controllers  - (SCGCQ00979952, Port of SCGCQ00915417)
 - Fixed an issue where Locate LED may remain on for reinserted drive - (SCGCQ00999675, Port of SCGCQ00997675)
 - Fixed an issue where a MonTask or DATATLB error may occur when there is Pinned Cache involving degraded, sliced Virtual Drives - (SCGCQ01023909, SCGCQ01023910, Port of SCGCQ00997180)
 - Fixed an issue where LED may not turn off when a drive is removed - (SCGCQ01026815, Port of SCGCQ01003387)
 - Fixed an issue where SEP devices at sasLevels greater than 1 may be determined as Direct Attached Devices - (SCGCQ01027840, Port of SCGCQ01004946)
 - Fixed an issue where a MonTask error may occur when IO, target resets and cable insert/remove are occurring simultaneously - (SCGCQ01028575, Port of SCGCQ00979797)
 - Fixed an issue where correct slot number may not be collected for SES enclosures - (SCGCQ00925533, SCGCQ01180864, Port of SCGCQ00903181)
 - Fixed an issue where drive may not be marked as Foreign on OCR when controller already has max configured drives - (SCGCQ01202208, Port of SCGCQ01163849)
 - Fixed an issue where controller configuration may be lost when connecting a stale configuration - (SCGCQ01205397, Port of SCGCQ01170701)
 - Fixed an issue where error "MonTask: line 3386 in file ../../dm/src/devmgr.c" may occur when running IO to JBOD SAS SSD and cables removed/reinserted - (SCGCQ01232131, Port of SCGCQ01213918)
 - Fixed an issue where error "adapter at base port not responding" may appear on boot when firmware issues mode sense command to faulty drives - (SCGCQ01001353, Port of SCGCQ00999966)
 - Fixed an issue where error "Firmware crash @line 245 in file ../../raid/1078int.c" may occur on enclosure power cycles - (SCGCQ01022262, Port of SCGCQ01015293)
 - Fixed an issue where message "I2C 4 PID 10 SCL STUCK Low! while I2C Rx receiving data intStatus 00008000" may still be printed in firmware log - (SCGCQ01026304, Port of SCGCQ01007592)
 - Fixed an issue where firmware returns an error when flashing individual components through storcli such as NVDATA, BTBL etc - (SCGCQ01030747, Port of SCGCQ01015302)
 - Fixed an issue where totalLines required to carry IO/Flush operation may not be restricted to primary core - (SCGCQ01033265, Port of SCGCQ01019324)


Enhancements:

 - Added Physical Layer library version 12.0.5.0 - (SCGCQ01231972)
 - Reverted DDR tuning changes for some controllers - (SCGCQ01224232)
 - Added Physical Layer 10.00.11.00 - (SCGCQ01194361)
 - Added AutoConfig feature support for 64VD mode - (SCGCQ01170212)
 - Added a feature for firmware to turn on fault LED for drives less than 512MB - (SCGCQ01156969)
 - Renamed HBA mode to JBOD mode - (SCGCQ01146813)
 - Added JBOD personality to MR_CTRL_PERSONALITY - (SCGCQ01146597)
 - Added supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES - (SCGCQ01141251)
 - Added interfaceType to MR_DEV_HANDLE_INFO - (SCGCQ01141229)
 - Added API support for TFM/SCAP _MR_BBU_VPD_INFO_ - Fixed parameters - (SCGCQ01139344)
 - Added new fields to MPI2_MR_PARAMS_PAGE_0 - (SCGCQ01137628)
 - Added a new control command to fetch ROC temperature data over I2C - (SCGCQ01137627)
 - Added a targetID interface to the API for system PD/JBOD drives - (SCGCQ01128348)
 - Added page-level retries for cache offload read commands with unrecoverable ECC errors - (SCGCQ01118692)
 - Implemented flash-level data scrambler support - (SCGCQ01118685)
 - Integrated Physical Layer 11.00.07.00 - (SCGCQ01117938)
 - Added 40-bit correction support for some controller's ONFI flash - (SCGCQ01093426)
 - Integrated Physical Layer 12.00.01.00 - (SCGCQ01070254)
 - Added feature to not use cache lines for FastPath failed IO - (SCGCQ01048213)
 - Added support to persist the MR_CFG_USER_CONFIGURABLE - (SCGCQ01046154)
 - Added ability to initiate a learn every 24 hours - (SCGCQ01043205)
 - Added support for new preboot tool HIIA - (SCGCQ01036145)
 - Added support for AutoConfiguration for EPDs - (SCGCQ01024552)
 - Added parallel drive microcode update support - (SCGCQ01023507)
 - Added additional EEDP error reporting capability so SCSI IO Reply - (SCGCQ01002367)
 - Modified "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout" - (SCGCQ00996127)
 - Integrated Physical Layer version 09.00.100.00 - (SCGCQ00995100)
 - Added some changes to CtrlDiag.c - (SCGCQ00993617)
 - Integrated Physical Layer version 09.00.59.00 - (SCGCQ00993610)
 - Improved performance of Write-through CacheCade Virtual Drives with respect to Write-back CacheCade Virtual Drives - (SCGCQ00991600)
 - Added additional EEDP Error Reporting capability to SCSI IO Reply  - (SCGCQ00988360)
 - Integrated Physical Layer from Phase 11 - (SCGCQ00988065)
 - Integrated Physical Layer 10.250.07.00 - (SCGCQ00950469)
 - Implemented recovery logic to recover good blocks that are falsely marked as bad - (SCGCQ00939352)
 - Addressed regression with POC 4 - (SCGCQ00928870)
 - Implemented profile management API for drivers and other external to application entities - (SCGCQ00867953)
 - Added MegaAPI modifications for FastPath ReadModifyWrite and Cache Bypass features - (SCGCQ00875328)
 - Added Private API modifications for FastPath ReadModifyWrite and Cache Bypass features - (SCGCQ00875330)
 - Merged api_overrides mega_api files with the files in the Mega_API development stream - (SCGCQ00883262)
 - Merged api_overrides pvt_api files with the files in the Pvt_API development stream - (SCGCQ00883315)
 - Updated NVDATA EEPROM tag for evaluation boards - (SCGCQ00898133)
 - De-featured AHCI support - (SCGCQ00941620)
 - Added Read-Ahead capable bit to communicate to driver that Read-Ahead is capable in firmware - (SCGCQ00987841)
 - Expanded MR_CTRL_INFO from 2K to 4K - (SCGCQ01023741)
 - Added support bit in controller info to inform storcli whether firmware is running in iButton or iButtonless mode - (SCGCQ01059740)
 - Added Private API changes for iButtonless operation - (SCGCQ01059744)
 - Added profile management changes to support requestedProfileID and optimisedProfile - (SCGCQ01075821)
 - Added Mega API changes to incorporate new IO subtype to support redirect cached IO - (SCGCQ01094549)
 - Added MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file - (SCGCQ01133839)
 - Added handling of parameters during behavior mode switch for OCR and reboot cases - (SCGCQ01060770)
 - Integrated Physical Layer library 09.00.102.00 - (SCGCQ01045607)
 - Updated CFGI and Physical Layer to SAS3.5 Phase 12 - (SCGCQ01041442)
 - Integrated Physical Layer 11.250.07.00 - (SCGCQ01038935)
 - Integrated Physical Layer 11.25.00.00 - (SCGCQ01037066)
 - Added feature to allocate alias targetID for EPDs when true multipath is enabled - (SCGCQ01024648)
 - Added true multipath host task management - (SCGCQ01024444)
 - Improved performance of Write-through CacheCade Virtual Drives with respect to Write-back CacheCade Virtual Drives - (SCGCQ01015822)
 - Added logging of SuperCap Fault Assertion along with associated status bits during runtime - (SCGCQ01011381)
 - Integrated Physical Layer 11.00.02.00 - (SCGCQ01010302)
 - Improved IO performance by disabling or enabling driver coalescing based on configuration - (SCGCQ00992516)
 - Added single-image offload for CacheVault single write mode - (SCGCQ01199671)
 - Integrated Physical Layer 12.00.03.00 - (SCGCQ01091093)
 - Changed DDR phy termination settings for some controllers - (SCGCQ01066266)
 - Integrated Physical Layer 12.00.01.00 - (SCGCQ01063510)
 - Added handling for 128 drives per enclosure - (SCGCQ00920037)
 - Integrated Physical Layer 12.00.05.00 - (SCGCQ01162534)
 - Added feature for firmware to complete SYNC_CACHE command for VDs even if mode page bit is disabled - (SCGCQ01125303)
 - Added feature to support exporting RAID geometry - (SCGCQ00936726)
 - Added "supported bits" mbox value to MR_DCMD_CFG_AUTOCFG - (SCGCQ01025967, Port of SCGCQ01020092)
 - Unblocked MCTP over PCIe levels - (SCGCQ01145325, Port of SCGCQ01134167)
 - Added MR_DCMD_CFG_AUTOCFG for iMR for GET operation - (SCGCQ01232103, Port of SCGCQ01228949)
 - Added capability to expose each SAS expander-attached SEP as a separate Enclosure PD - (SCGCQ01150206, Port of SCGCQ01093800)
 - Converted some unrecoverable errors to recoverable errors - (SCGCQ00943806, Port of SCGCQ00890049)
 - Added feature to handle the presence and absences of randomizer - (SCGCQ01156575, Port of SCGCQ01133554)
 - Added support for SCSI SANITIZE/Crypto commands on JBOD drives - (SCGCQ01144707, Port of SCGCQ01129378)
 - Removed reset of Idle Timers - (SCGCQ01223113, Port of SCGCQ01145782)
 - Added ability to allow security commands to drives which are not managed by SafeStore - (SCGCQ01026630, Port of SCGCQ01007634)
 - Added changes for Profile management API support - (SCGCQ00883008, SCGCQ00883045)

Version 24.12.0-0038 - High Impact/High Probability of Occurrence
-------------------
FW Package:  24.12.0-0038
HII:  E3.19.07.06
UEFI Driver: 0x06130201
BIOS:  6.30.03.2
iMR FW:  4.620.01-8078

Fixes:
 - Disabled further usage of PI due to a potential data issue (SCGCQ01128078)
 - Fixed an issue where In CTRL-R the controller is giving the option to enable the drive protection under controller operations (F2) with firmware which does not support the data protection. (SCGCQ01139294, SCGCQ01074426, SCGCQ01131138)
 - Fixed an issue where a configured drive is inserted, rebuild started on wrong virtual drive after the enclosure power cycle. (SCGCQ00988970 Port of SCGCQ00927155)
 - Fixed an issue where the screen is not refreshing after operations in CTLR-R. (SCGCQ01088160)
 - Fixed an issue where controller broke into montask upon reboot after running a rebuild and reconstruction. (SCGCQ01088178 Port of SCGCQ00902755)
 - Fixed an issue where /O failures observed on 4k virtual drive with data Protection Enabled, when virtual drive goes offline due to source drive error when Rebuild is progressing on a degraded virtual drive (SCGCQ01130941 Port of SCGCQ01081912)
 - Fixed an issue for iMR where the supported configurable physical drive count is already filled and more configured drives are added and get converted to JBOD and their configuration was cleared. (SCGCQ01149762)
 - Fixed an issue where data compare error found during recovery of CacheCade pinned windows across OCR/Reboot or discard of CacheCade pinned windows while CacheCade degrade flush in progress. (SCGCQ01136062)
 - Fixed an issue where iEEESGL flag was not getting set for IO request in SES DCDB handler. (SCGCQ01186523 Port of SCGCQ01157072)
 - Fixed an issue where L2/L3 Cache error was detected on the RAID controller during boot. (SCGCQ01155454 Port of SCGCQ01018958)

Enhancement(s):
 - SCSI SANITIZE/Crypto on JBOD Drives under MR. (SCGCQ01155380 Port of SCGCQ01129378)
  

Version 24.12.0-0033 - High Impact/High Probability of Occurrence
-------------------

FW Package: 24.12.0-0033
HII: E3.19.07.06
UEFI Driver: 0x06130201
BIOS: 6.30.03.2
MR FW: 4.620.00-7178
iMR FW: 4.620.01-7179

Fixes:
 - Fixed an issue where changing RAID FoD key (Add/Remove) through customer application will make the original VD change to foreign. (SCGCQ01111615)
 - Fixed an issue where security is disabled on a ServRAID M5210 controller after a FOD key is added or removed until next reboot.  (SCGCQ01132432)

Enhancement:
 - Added the capability for users to save the FoD key to TMM through the MSM pop-up advanced software options.  (SCGCQ01085797) 

Version 24.12.0-0024 - High Impact/High Probability of Occurrence
-------------------
 FW Package: 24.12.0-0024
HII: E3.19.07.03
UEFI Driver: 0x06130200
BIOS: 6.30.03.0
MR FW: 4.620.00.6070 
iMR FW: 4.620.01.6071


 Fixes:
 - Fixed the potential of a data miscompare that was observed only at a vendor test facility under very heavy I/O and abnormal practices (SCGCQ00990093, Port of SCGCQ00976904)
 - Fixed an issue where performing back-to-back target resets on the same JBOD may results in an Controller Reset (SCGCQ00857181)
 - Fixed an issue where firmware may allow a Reconstruction to be performed when Pinned Cache is present (SCGCQ00857692)
 - Fixed an issue where "MonTask" error may occur when importing a Foreign Configuration (SCGCQ00860066)
 - Fixed an issue where controller does not Stop on Error and boots into Operating System when Pinned Cache is present(SCGCQ00860503)
 - Fixed an issue where firmware allows CacheCade Virtual Drive deletion when Pinned Cache is present (SCGCQ00871973)
 - Fixed an issue where a firmware downgrade FW downgrade may fail when IO and Background Operations are being performed (SCGCQ00873239)
 - Fixed an issue where error "Core 0 exception in line 245 in ../../raid/1078int.c" may occur when Target Reset sent to Physical Disks in parallele with Background Operations (SCGCQ00878554)
 - Fixed an issue where error "Assertion failure in ../../dm/src/dmDrvPrep.c at line 836" may occur (SCGCQ00879198)
 - Fixed an issue where firmware may hang on Task Abort (SCGCQ00881901)
 - Fixed an issue where iPtr and rPtr values may be greater than the size of the buffer (SCGCQ00886685)
 - Fixed an issue where more IOs were allowed than the available buffer could support (SCGCQ00894472)
 - Fixed an issue where the Operating System may become unresponsive after creating multiple sliced Virtual Disks (SCGCQ00894608)
 - Fixed an issue where adapter may reset under certain conditions (SCGCQ00895554)
 - Fixed an issue where error "line 1271 in file ../../raid/1078dma.c" may occur when running FastPath with CacheCade (SCGCQ00898799)
 - Fixed an issue where forceCacheFlush was occurring in an iMR context where it doesn't apply (SCGCQ00899762)
 - Fixed an issue where importing 240 Virtual Drives may cause a firmware fault (SCGCQ00900601)
 - Fixed an issue where error "line 229 in file ../../raid/mtask.c" may occur when Hibernating Windows 10 (SCGCQ00905864)
 - Fixed an issue where importing a Foreign Configuration may fail (SCGCQ00908325)
 - Fixed an issue where FastPath IO may not time out properly (SCGCQ00910124)
 - Fixed an issue where StorCLI may report an incorrect ScapBatVersionNO when using command "/c0/cv show all" (SCGCQ00914343)
 - Fixed an issue where some default values may not be picked up for unchanged controller properties sharing the same byte (SCGCQ00914740)
 - Fixed an issue where chain mid allocation for JBOD may fail (SCGCQ00915081)
 - Fixed an issue where configuration creation may fail after creation of a CacheCade Virtual Drive followed by JBOD creation (SCGCQ00917307)
 - Fixed an issue where a cable pull during a Target Reset on JBOD may result in a data TLB error (SCGCQ00923289)
 - Fixed an issue where controller may become unresponsive after hitting an OCM error(SCGCQ00924986)
 - Fixed an issue where the Physical Device map was being updated unnecessarily (SCGCQ00927173)
 - Fixed an issue where some drives could not be discovered successfully (SCGCQ00927792)
 - Fixed an issue where attempting to stop a Drive Erase operation from application may cause firmware to hang (SCGCQ00928150)
 - Fixed an issue where controller disappears when performing a cable pull (SCGCQ00928333)
 - Fixed an issue where CacheCade Virtual Drive creation may fail with false error (SCGCQ00930044)
 - Fixed an issue where controller may hang when importing a drive into a RAID0 CacheCade Virtual Drive (SCGCQ00934196)
 - Fixed an issue where firmware would not allow an Online Firmware Update (SCGCQ00936693)
 - Fixed an issue where error "line 219 in file ../../raid/mficmd.c" may occur when powering system on from S3 sleep (SCGCQ00937487)
 - Fixed an issue where error "MonTask: line 1281 in file /raid/1078dma.c" may occur when running enclosure cable pulls with CacheCade Virtual Drive (SCGCQ00941531)
 - Fixed an issue where firmware recovers invalid cache after firmware update (SCGCQ00944012)
 - Fixed an issue where LdInitPdDone did not include flush command block (SCGCQ00945033)
 - Fixed an issue where driver may panic and controller may reset on medium errors with Pinned Cache (SCGCQ00948257)
 - Fixed an issue where Virtual Drives don't revert back to Write-Back once the controller Pinned Cache is destaged (SCGCQ00948466)
 - Fixed an issue where firmware may fault when running full initialization on Virtual Drives with LDBBM entries created during Consistency Check (SCGCQ00952627)
 - Fixed an issue where a SES Discovery Error may occur on repeated retries for some expanders (SCGCQ00976741)
 - Fixed an issue where the drive bay LED may not turn off when the drive is removed (SCGCQ01003387)
 - Fixed an issue where error "MonTask: line 4946 in file ../../raid/ld.c" may occur when multipath cable pull occurs Patrol Read (SCGCQ00857528)
 - Fixed an issue where Locate LED turns off when cable failover performed (SCGCQ00869681)
 - Fixed an issue where "Watchdog Timer Exception" error followed by firmware fault after initiating Physical Drive erase operation (SCGCQ00872140)
 - Fixed an issue where a firmware fault occurs when issuing Task Management commands on 240 JBODs while running IO (SCGCQ00872889)
 - Fixed an issue where Virtual Drive deletion could cause IO freeze time to increase (SCGCQ00873201)
 - Fixed an issue where a data TLB error would occur after issuing task abort (SCGCQ00873991)
 - Fixed an issue where "MonTask" error may occur due to a Full-Disk Encryption / Self-Encrypting Disk that fails to spinup (SCGCQ00874332)
 - Fixed an issue where error "adapter at baseport not responding" may occur (SCGCQ00880919)
 - Fixed an issue where cache is not flushed immediately upon firmware recieving the cache-flush out-of-band command (SCGCQ00882125)
 - Fixed an issue where IO may slow while deleting Virtual Drives  (SCGCQ00891924)
 - Fixed an issue where IO halts on JBODs with "read/write error" when the target drives are reset in Linux (SCGCQ00893588)
 - Fixed an issue where "MonTask: line 1413 in file ../../raid/config.c" may occur when creating a CacheCade Virtual Drive (SCGCQ00894610)
 - Fixed an issue where firmware does not log controller property change event for enabling/disabling 240VD feature (SCGCQ00895577)
 - Fixed an issue where event length may come up as 0 (SCGCQ00897406)
 - Fixed an issue where firmware was not seding the proper status for aborted commands (SCGCQ00900250)
 - Fixed an issue where controller firmware may fault during Hibernation or when the driver loads twice (SCGCQ00902938)
 - Fixed an issue where firmware may fault after creating 240 Virtual Drives and rebooting the server (SCGCQ00905416)
 - Fixed an issue where progress for CacheCade disassociation activity is not displayed for all source Virtual Drives (SCGCQ00906846)
 - Fixed an issue where error "Assert at line 1181 mpthostcmd.c" may occur when FastPath has been disabled or for a timeout IO (SCGCQ00910006)
 - Fixed an issue where error "LMID HS-FIFO Error 0x8" may occur when removing a redundant path to a JBOD with IO (SCGCQ00914274)
 - Fixed an issue where applications may show incorrect value for Max Parallel Commands field of Controller Information in iMR(SCGCQ00914751)
 - Fixed an issue where firmware was failing ABORT TASK and ABORT TASK SET commands on SATA JBOD (SCGCQ00915088)
 - Fixed an issue where exception may occur on Online Controller Reset (SCGCQ00917523)
 - Fixed an issue where "MonTask" error may occur in a drive removal or multipath removal scenario (SCGCQ00919229)
 - Fixed an issue where the wrong MFI_STAT is returned from PdDcmdSysPdMapAbort (SCGCQ00930593)
 - Fixed an issue where an Online Firmware Update may fail when downgrading from firmware that supports 240 Virtual Drives to firmware that does not (SCGCQ00930917)
 - Fixed an issue where "DM_EnableFastPathOnDevice ::  FP enabled on devhandle" may be printed in logs even though FastPath is enabled (SCGCQ00936617)
 - Fixed an issue where "C0:Index 0098 allocated from pool 3" prints continuously in log with 12Gbps Enclosures and SATA drives (SCGCQ00937572)
 - Fixed an issue where firmware prematurely rejects ONFI flash module (SCGCQ00937617)
 - Fixed an issue where SafeID may change on repeated queries using StorCLI (SCGCQ00941577)
 - Fixed an issue where firmware may fault when importing Virtual Drives with Pinned Cache (SCGCQ00949440)
 - Fixed an issue where Write-Back Virtual Drives are converted to Write-Through on system reboot or Online Controller Reset(SCGCQ00859720)
 - Fixed an issue where a Data TLB error may occur when firmware is upgraded or downgraded (SCGCQ00867065)
 - Fixed an issue where a Data TLB error may occur when aborting a host command (SCGCQ00874357)
 - Fixed an issue where firmware may fault when running IO with Task Resets on JBODs (SCGCQ00877673)
 - Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur while running IO with 64 Virtual Drives and removing drives belonging to CacheCade (SCGCQ00878587)
 - Fixed an issue where cache flush was occurring during Virtual Drive deletion (SCGCQ00878923)
 - Fixed an issue where IO dip is seen when deleting Virtual Drives (SCGCQ00879193)
 - Fixed an issue where a Data TLB error may occur when sending Target Reset on JBOD via out-of-band commands (SCGCQ00881919)
 - Fixed an issue where perTunerMode is not set correctly after a controller reset (SCGCQ00882897)
 - Fixed an issue where error "MonTask: line 2735 in file ../../ssd/ssd_cache_fw.c" may occur when error are injected repeatedly (SCGCQ00887019)
 - Fixed an issue where a rebuild cannot be started for a degraded CacheCade Virtual Drive after heavy IO (SCGCQ00887428)
 - Fixed an issue where error "MonTask: line 245 in file ../../raid/1078int.c" may occur with IOs on maximum Virtual Drives configured and Background Opertations are occurring (SCGCQ00890133)
 - Fixed an issue where Patrol Read doesn't resume after Consistency Check completes after a system reboot (SCGCQ00894344)
 - Fixed an issue where StorCLI throws an error when performing "/c0/vx show all" after a Full Initialization on RAID1 Virtual Drive with SSDs (SCGCQ00904899)
 - Fixed an issue where a firmware fault occurs when a copyback operation fails to start (SCGCQ00904905)
 - Fixed an issue where LUID is changed when importing a non-240VD configuration to a 240VD firmware (SCGCQ00907658)
 - Fixed an issue where a "MonTask" error may occur when under heavy JBOD IO and the JBOD IOs begin failing (SCGCQ00915078)
 - Fixed an issue where error "line 1279 in file ../../raid/1078dma.c" may occur on iMR firmware during boot (SCGCQ00915092)
 - Fixed an issue where controller reset occurs under stress with 240 Virtual Drives configured (SCGCQ00915398)
 - Fixed an issue where Online Firmware Update would fail due to driver reload issues (SCGCQ00915454)
 - Fixed an issue where a Data TLB error may occur during reconstrution operation when Target Resets are issued to JBODs (SCGCQ00921993)
 - Fixed an issue where "Core 0 exception" is seen when trying to import Foreign Configurations with Pinned Cache (SCGCQ00863880)
 - Fixed an issue where CTRL-R interface does not show correct port information when hotplugging enclosure paths (SCGCQ00866487)
 - Fixed an issue where firmware may fault when an enclosure with an especially slow drive is present (SCGCQ00867120)
 - Fixed an issue where error "MonTask: line 1280 in file ../../raid/1078dma.c" may occur on out-of-band command timeout (SCGCQ00872875)
 - Fixed an issue where error "Assertion failure in ../../raid/cache.c at line 774" may occur after pulling out an enclosure cable (SCGCQ00878097)
 - Fixed an issue where write performance drops in RAID5, Write-Through, No Read-Ahead, Stripe Size 64, 1MB IO at queue depth 128/256 (SCGCQ00878414)
 - Fixed an issue where an imported 4K-drive RAID0 becomes Unconfigured Good on reboot (SCGCQ00895689)
 - Fixed an issue where Online Firmware Update fails with "not supported" message (SCGCQ00915073)
 - Fixed an issue where Logical Drive IO for FastPath-capable RAID0/RAID1 were not handled properly in the presence of a RAID5/RAID6 Write-Through volume running sequential write streams (SCGCQ00915409)
 - Fixed an issue where a CRC mistmatch and Invalid Log Event are surfaced when checking Controller Properties in parallel with a Learn Cycle (SCGCQ00919945)
 - Fixed an issue where performance drops are seen on writes to RAID1 FastPath volumes (SCGCQ00931895)
 - Fixed an issue where event messages reporting CacheCade Virtual Disk target ID and remaining CacheCade size are incorrect (SCGCQ00864019)
 - Fixed an issue where firmware faults when using an Online Controller Reset from StorCLI after having issued "supportResetNow" (SCGCQ00878150)
 - Fixed an issue where an "Exception in Core -0" error may occur on iMR firmware under VMWare (SCGCQ00904103)
 - Fixed an issue where "MsgAlloc: No free messages, poolIndex=4" may appear in logs while running IO on JBODs (SCGCQ00908982)
 - Fixed an issue where the TTY log dump is not persistent across multiple boots (SCGCQ00877100)
 - Fixed an issue where drives that return errors for all protocol commands may be retried indefinitely (SCGCQ00805369)
 - Fixed an issue where setting the Learn Cycle property of iBBU09 gives an i2C error (SCGCQ00837206)
 - Fixed an issue where driver may hang with LSI2008-based adapters (SCGCQ00843390)
 - Fixed an issue where device wait queue is not cleared when drive is no longer online (SCGCQ00878401)
 - Fixed an issue where Windows may BSOD on firmware upgrade when running driver 6.707.08.00 (SCGCQ00886272)
 - Fixed an issue where disableImmediateIO NVDATA value is not honored by firmware (SCGCQ00886666)
 - Fixed an issue where Foreign Configuration could be cleared even when Pinned Cache is present (SCGCQ00889209)
 - Fixed an issue where a Virtual Drive under Reconstruction may go Degraded if the drive being reconstructed is removed before the operation completes (SCGCQ00891282)
 - Fixed an issue where a "MonTask" error may occur after initiating a RAID Level Migration (SCGCQ00891288)
 - Fixed an issue where system hang may occur after aborting running Consistency Checks repeatedly (SCGCQ00895265)
 - Fixed an issue where a "MonTask" error may occur after creating 240 Virtual Drives and rebooting the server (SCGCQ00908121)
 - Fixed an issue where LUID is changed when importing a non-240VD configuration to 240VD-enabled controller (SCGCQ00908153)
 - Fixed an issue where a Virtual Drive may disappear on reboot if created with drives from a previously-deleted Virtual Drive (SCGCQ00914823)
 - Fixed an issue where device wait queue is not cleared if a drive is no longer online (SCGCQ00923279)
 - Fixed an issue where message "Found invalid event at fc4966ec" is printed in firmware log every 5 seconds (SCGCQ00931370, SCGCQ00979910)
 - Fixed an issue where firmware is unable to detect all Virtual Drive's "Degraded" status for partial Virtual Drives created on the same Physical Drives (SCGCQ00942380)
 - Fixed an issue where driver may panic and firmware may hang when medium errors are present (SCGCQ00954118)
 - Fixed an issue where firmware does not discard dirty cache after firmware update (SCGCQ00992657)
 - Fixed an issue where some Recoverable Errors were marked as Unrecoverable (SCGCQ01015699)
 - Fixed an issue where HII and Ctrl-R show an incorrect message when trying to import a 65th Virtual Drive (SCGCQ00803718)
 - Fixed an issue where Functional Level Reset (FLR) was not supported (SCGCQ00843936)
 - Fixed an issue where Write-through and Write-back cache policies can be changed via Windows Logical Disk Properties. (SCGCQ00883311)
 - Fixed an issue where many "LdDcmd ***** return pinned list 0" messages may be printed in firmware log (SCGCQ00895459)
 - Fixed an issue where an alert is repeated twice for Cancel Consistency Check on Virtual Drives (SCGCQ00900027)
 - Fixed an issue where error "Controller encountered fatal error and was reset" may occur under heavy IO and background operations (SCGCQ00905603)
 - Fixed an issue where CacheCade-related 240 Virtual Drive checks were not checking controller properties (SCGCQ00905809)
 - Fixed an issue where out-of-band applications may not display Show Configuration Summary when 240 Virtual Drives are created (SCGCQ00908237)
 - Fixed an issue where a RAID0 using 4k drives may not be visible after reboot (SCGCQ00999181)
 - Fixed an issue where firmware may not poll all temperature sensor channels every 5 seconds (SCGCQ00844152)
 - Fixed an issue where Hard Drive RAID0 and RAID10 performance at 1M stripe size is suboptimal between queue depths of 16 to 256 (SCGCQ00876154)
 - Fixed an issue where StorCLI will report Success when flashing an MR-only package on an iMR-only controller (SCGCQ00882149)
 - Fixed an issue where 'Fw initializing devices' may hang with specific failed drives (SCGCQ00884719)
 - Fixed an issue where controller may report cache size as "0" when no logical drives are present (SCGCQ00891273)
 - Fixed an issue where a Physical Disk may not go to Online state even after creating a Virtual Drive on it (SCGCQ00910741)
 - Fixed an issue where error "SAS core detected EEDP error in application tag" may occur (SCGCQ00936647)
 - Fixed an issue where "storcli /c0 show all" shows many Bad Block messages in the log (SCGCQ00892136)
 - Fixed an issue where firmware may log Controller Properties Changed events twice (SCGCQ00908238)
 - Fixed an issue where a Virtual Drive under Reconstruction may be set Degraded if the drive under reconstruction is removed (SCGCQ00922677)
 - Fixed an issue where firmware may enter fault state after system power cycle with an SSD drive (SCGCQ00835227)
 - Fixed an issue where firmware may fault and RSOD may occur when a Virtual Drive is deleted when a Reconstruction is in progress on a PI-enabled VD combined with a slow initialization on another Virtual Drive (SCGCQ00872263)
 - Fixed an issue where firmware doesn't report no SMART error when a Predictive-Failure Analysis (PFA) drive is present (SCGCQ00841772)
 - Fixed an issue where firmware may not detect inserted drives (SCGCQ00876142)
 
 Enhancements:
 - Added support for restarting Patrol Reads after they are interrupted by a Consistency Check (SCGCQ00883176)
 - Added ability to enable and disable 1M IO support via controller property (SCGCQ00893029)
 - Added support for Task Management for JBOD/sysPDs (SCGCQ00855457)
 - Reduced Command Block latency during Background Operations (SCGCQ00865372)
 - Added ability to not moe Write-back Virtual Drives to Write-through when Pinned Cache is less than 50% of available buffers (SCGCQ00852502)
 - Updated iMR queue depth to 928 (SCGCQ00888862, SCGCQ00930846, SCGCQ00896497)
 - Disabled SATA HOQ support for iMR controllers (SCGCQ00942547)
 - Added Task Management support for JBOD/sysPD (SCGCQ00861819, SCGCQ00855457)
 - Re-enabled 1M IO support (SCGCQ00874200)
 - Added support for Event Reporting for SuperCap Health after Learn Cycles (SCGCQ00894455)    

Version 24.9.0-0029 - High Impact/High Probability of Occurrence
-------------------
Fixes:
 - Fixed an issue where controller cache fails to de-stage when multiple source VDs are present in a CacheCade configuration - (SCGCQ00854169, Port of SCGCQ00842625)
 - Fixed an issue where a VD created with drives from a previously erased VD may disappear on next reboot - (SCGCQ00900237)
 - Fixed an issue where StorCLI allows a user to hide a boot drive which is already in the Hidden state - (SCGCQ00885733, Port of SCGCQ00883996)
 - Fixed an issue where "MonTask: line 245 in file ../../raid/1078int.c" error may be seen when drives are removed in a configuration with 64VDs and CacheCade - (SCGCQ00889884, Port of SCGCQ00878587)
 - Fixed an issue where some forms out Out-of-band controller management may not display Show Configuration Summary when 240VDs are created - (SCGCQ00910375, Port of SCGCQ00904833)
 - Fixed an issue where a 'Watchdog Timer Exception' may occur followed by a Fatal FW error after initiating a PD Erase on an Unconfigured Good PD, with Background operations and IOs occurring - (SCGCQ00898359, Port of SCGCQ00872140)
 - Fixed an issue where Locate may not work on a JBOD physical drive - (SCGCQ00903649)
 - Fixed an issue where the LUID may change during a Foreign Import from non-240VD FW to 240VD FW - (SCGCQ00907682, Port of SCGCQ00907658)
 - Fixed an issue where command block latency was too high during Background operations, which could cause a controller firmware hang when deleting a CacheCade VD - (SCGCQ00911790, Port of SCGCQ00865372)
 - Fixed an issue where medium error correction events were not being surfaced - (SCGCQ00846621)
 - Fixed an issue where "MonTask: line 1272 in file ../../raid/1078dma.c" error may occur after injecting media errors on loop to a CacheCade VD - (SCGCQ00833945, Port of SCGCQ00822477)
 - Fixed an issue where deleting a CacheCade VD could result in a firmware hang situation - (SCGCQ00849620, Port of SCGCQ00844698)
 - Fixed an issue where unexpected Automatic Event Notifications of "Initialization aborted on VD___ due to controller reset" - (SCGCQ00904475, Port of SCGCQ00864348)
 - Fixed an issue where firmware may report "Disabling writes to flash due to a critical error" - (SCGCQ00917202, Port of SCGCQ00901119)
 - Fixed an issue where a reconstruction may fail with error "invalid arguments" - (SCGCQ00894719)
 - Fixed an issue where MSM shows "null x0" to describe port connection to enclosure when multipath is broken - (SCGCQ00898564)
 - Fixed an issue where an invalid boot device could be selected - (SCGCQ00914515)
 - Fixed an issue where "Set factory default" does not reset modified PHY link speeds - (SCGCQ00925640)
 - Fixed an issue where a StorCLI show all command triggers a data store disconnect on a (3) RAID5 VDs in VMWare ESXi - (SCGCQ00928506)
 - Fixed an issue where FastPath IOs that have timed out may be retried - (SCGCQ00922542, Port of SCGCQ00910124)
 - Fixed an issue where creation of configuration on a controller fails after the creation of a CacheCade VD followed by a JBOD creation - (SCGCQ00923405, Port of SCGCQ00917307)
 - Fixed an issue where "Controller encountered a fatal error and was reset" during stress and a is drive pulled - (SCGCQ00929474, Port of SCGCQ00916037)
 - Fixed an issue where "Adapter at base port not responding" error may occur on boot - (SCGCQ00899333, Port of SCGCQ00880919)
 - Fixed an issue where MSM shows messages with Error Code 240 and no description - (SCGCQ00904466)
 - Fixed an issue where handling of Functional Level Reset (FLR) is not present - (SCGCQ00911773, Port of SCGCQ00840253)
 - Fixed an issue where a "Data Translation Look aside Buffer" error may occur when resetting a target with multiple cable pulls - (SCGCQ00886910, Port of SCGCQ00881919)
 - Fixed an issue where "MonTask: line 245 in file ../../raid/1078int.c with IOs on max VD configured and BGOps" error may occur - (SCGCQ00898761, Port of SCGCQ00890133)
 - Fixed an issue where some PDs don't go online after creating a VD on drives with different sizes - (SCGCQ00911685, Port of SCGCQ00834734)
 - Fixed an issue where firmware might log MR_EVT_CTRL_PR_PROP_CHANGED twice - (SCGCQ00910389, Port of SCGCQ00908165)
 - Fixed an issue where LUID changes during foreign import from non-240VD firmware to 240VD firmware - (SCGCQ00908894, Port of SCGCQ00907658)
 - Fixed an issue where "MonTask: line 1278 in file ../../raid/1078dma.c" error may occur after importing PDs with pinned cache - (SCGCQ00913426)
 - Fixed an issue where "MonTask: line 4946 in file ../../raid/ld.c while multipath push pull with patrol read" may occur when doing multipath cable removals while Patrol Read in progress - (SCGCQ00876061, Port of SCGCQ00857528)
 - Fixed an issue where imported RAID0 using 4k drives is not visible after reboot - (SCGCQ00910569, Port of SCGCQ00895689)
 - Fixed an issue where Copyback fails to start and causes a firmware fault - (SCGCQ00908347, Port of SCGCQ00904905)
 - Fixed an issue where hot removal followed by hot add of a drive into an array causes a Blue Screen of Death - (SCGCQ00923113, Port of SCGCQ00901919)
 - Fixed an issue where controller report a Fatal Firmware Error and controller reset when creating 240VDs - (SCGCQ00880907)
 - Fixed an issue where an already-present configuration is showing as foreign after upgrade from non-240VD firmware to 240VD firmware - (SCGCQ00925394)
 - Fixed an issue where firmware breaks into MonTask when importing a foreign configuration - (SCGCQ00898473, Port of SCGCQ00860066)
 - Fixed an issue where "Warning Error during boot - Configuration command was not committed, please retry" error occurs on update from non-240VD firmware to 240VD firmware - (SCGCQ00928699)
 - Fixed an issue where controller may encounter a fatal error and reset during stress and drive removal - (SCGCQ00916037)
 - Fixed an issue where firmware may hang at "LogInit: Flushing events from previous boot" while running policy change script - (SCGCQ00833849, Port of SCGCQ00797643)
 - Fixed an issue where a Core 0 Exception may be seen while trying to import a foreign configuration with pinned cache present - (SCGCQ00898730, Port of SCGCQ00863880)
 - Fixed an issue where PI message "SAS core detected EEDP error in application tag" may occur after firmware upgrade - (SCGCQ00934617, Port of SCGCQ00925591)
 - Fixed an issue where IO may halt with read/write error when the target drives are reset via MFI or MPT path in Linux - (SCGCQ00893924, Port of SCGCQ00893588)
 - Fixed an issue where deletion of CacheCade VD the firmware displays the wrong CacheCade target ID and remaining CacheCade size in system - (SCGCQ00898780, Port of SCGCQ00864019)
 - Fixed an issue where importing 240VD configuration leads to firmware crash - (SCGCQ00922541, Port of SCGCQ00900601)
 - Fixed an issue where DMA would not halt at first DIF error and go through error recovery mechanism to try and recover the data - (SCGCQ00907673)
 - Fixed an issue where Random Write performance may drop up to 30% in 2-drive RAID1 with write-back and read-ahead - (SCGCQ00908885)
 - Fixed an issue where "Controller encountered fatal error and was reset" under heavy IOs and background operations - (SCGCQ00922716, Port of SCGCQ00894643)
 - Fixed an issue where TTY log dump is not persistent for multiple boots - (SCGCQ00898762, Port of SCGCQ00877100)
 - Fixed an issue where a CRC mismatch and invalid log event are found while querying for Controller properties - (SCGCQ00934619, Port of SCGCQ00919945)
 - Fixed an issue where "MonTask: line 1280 in file ../../raid/1078dma.c" may occur when pass-through commands and cable-removal tests are performed at the same time - (SCGCQ00899818, Port of SCGCQ00872875)
 - Fixed an issue where Windows may Blue Screen of Death when upgrading firmware with driver 6.707.08.00 - (SCGCQ00884589)
 - Fixed an issue where ECC errors may cause a controller reset - (SCGCQ00849554, Port of SCGCQ00825126)
 - Fixed an issue where firmware may break into MonTask on reboot after creating 240VDs - (SCGCQ00907679, Port of SCGCQ00905416)
 - Fixed an issue where discovery may fail with "Unable to get SCSI Device Information from the system" - (SCGCQ00928449)
 - Fixed an issue where CacheCade performance may be lower than expected - (SCGCQ00911438)

Enhancements:
- Added support for ServeRAID M1210 SAS/SATA Controller
- Added a feature to block upgrading or downgrading firmware when a reconstruction is in progress, and block reconstructions from starting if a firmware upgrade or downgrade is in progress - (SCGCQ00915869)

History content below is for M1215 from the superseded lnvgy_fw_sraidmr_1215* update pacakges.


History content below is for M1215 from the superseded lnvgy_fw_sraidmr_1215* update pacakges.

Version 24.9.0-0026 - High Impact/High Probability of Occurrence
-------------------
Enhancements:
- Added more descriptive port information to include link width in PHYs (SCGCQ00854621)

Fixes:
 - Fixed an issue in iMR mode where "Controller encountered fatal error and was reset" errors can occur under heavy IOs and background operations (SCGCQ00894643) (RETAIN Tip H001154) 
 - Fixed an issue where driver health protocol may report unhealthy if more than 64 VDs are configured (SCGCQ00830918)
 - Fixed an issue where VDs beyond 64 may not be reported in legacy OpROM pOST display list (SCGCQ00826174)
 - Fixed an issue where "StorCLI /cX add VDs detailed" menu provides incorrect syntax for R1E (SCGCQ00501437)
 - Fixed an issue where CLI "show all" command fails with error "Error! App exec failed in FW PCLIError! Internal" (SCGCQ00518543)
 - Fixed an issue where the dedicated hot spare option in HII may be grayed out for RAID1 under the profile based configuration menu (SCGCQ00873973)
 - Fixed an issue where HII drive management and enclosure management may report only port 4-7 connected when ports 0-3 and 4-7 are connected to the same expander (SCGCQ00870398)
 - Fixed an issue where HII may hang or multiple enclosure entries will be seen in  enclosure eanagement form after repeated navigation (SCGCQ00878350)
 - Fixed an issue where a 15-character VD name is truncated to 14 characters (SCGCQ00854606)
 - Fixed an issue where profile-based VD creation menu doesn't explain each profile's drive selection criteria (SCGCQ00884229)
 - Fixed an issue where some overlap may be seen during legacy OpROM pOST when more than one controller is present and there are boot messages for the second controller (SCGCQ00866982)
 - Fixed an issue where MSM may display "The requested command has invalid arguments" when 'Schedule Consistency Check' is selected (SCGCQ00832908)
 - Fixed an issue where a controller may not be accessible through RAIDLink until the OS is up and running (SCGCQ00847001)
 - Fixed an issue where drive firmware on certain SED/FDE SATA SSDs could not be updated (SCGCQ00856977)
 - Fixed an issue where an error "MonTask: line 1272 in file ../../raid/1078dma.c" may occur while running IO in a virtual machine (SCGCQ00822403)
 - Fixed an issue where a JBOD PD may not be able to be converted to Unconfigured Good in Solaris (SCGCQ00834552)
 - Fixed an issue where an "Instruction TLB" error may occur when a StorCLI /cX set autopdcache=r0 or similar command is executed (SCGCQ00835586)
 - Fixed an issue where firmware may hang in multipath scenario when cable pull/push test is performed at the same time as an array property change is issued (SCGCQ00836496)
 - Fixed an issue where a secure erase on a SATA SSD in HII may fail or lead to a hang in HII (SCGCQ00841317)
 - Fixed an issue where the controller may reset in some situations with media errors and VD undergoing manual rebuild after drives are taken offline, under stress (SCGCQ00825126)
 - Fixed an issue where the 3x08 chip Errata ID - 2012-RC714 may lead to PCIE 3.0 hot reset non-compliance (SCGCQ00829129)
 - Fixed an issue where rebuild performance on RAID1 is always slower than other RAID configurations (SCGCQ00841359)
 - Fixed an issue where patrol read properties window won't show up in MSM (SCGCQ00797676)
 - Fixed an issue where an L2 unrecoverable cache error may be seen during patrol read properties modification when VDs are made offline (SCGCQ00847162)
 - Fixed an issue where a VD erase may not resume after reboot when a CacheCade VD is present (SCGCQ00851810)
 - Fixed an issue where controller boots to OS even when pinned cache is present and boot error handling is set to stop on error (SCGCQ00860503)
 - Fixed an issue where firmware cannot detect some newly-inserted drives (SCGCQ00860270)
 - Fixed an issue where "MonTask: line 1518 in file ../../raid/2108vI2o.c" may occur in conjunction with a VMWare Guest abrupt shutdown (SCGCQ00852670)
 - Fixed an issue where connector name field is displayed as port 4-7 when actually both ports 0-3 and 4-7 are connected (SCGCQ00868215)
 - Fixed an issue where "line 243 in file ../../raid/1078int.c" error may occur during rebuild (SCGCQ00856256)
 - Fixed an issue where no error message shown when there is a failure to disable SSD caching of an offline VD (SCGCQ00905310)
 - Fixed an issue where "1 JBOD(s) found on the host adapter" may appear in legacy OpROM post even though no JBODs are present (SCGCQ00882729)
 - Fixed an issue where firmware may halt with "line 245 in file ../../raid/1078int.c" in log under stress with maximum VDs and background operations (SCGCQ00890133)
 - Fixed an issue where the HII may report a different Battery/SuperCap status than
   MSM/StorCLI would (SCGCQ00879726)
 - Fixed an issue where the firmware may hang due to an "Illegal Instruction Exception" error (SCGCQ00850441)
 - Fixed an issue with less-than-expected performance of Write-Verify SCSI commands in RAID0 (SCGCQ00866261)

Version 24.7.0-0056 - High Impact/High Probability of Occurrence
-------------------
Fixes:
- Fixed issue where UNMAP or TRIM commands might fail on SSD in JBOD Mode (SCGCQ00853147) (RETAIN Tip H214381)


Version 24.7.0-0052 - High Impact/High Probability of Occurrence
-------------------
Fixes:
- Incorporated MegaRAID FW stack 6.6
- Fixed an issue where a drive reporting itself as 0MB shows up as Unconfigured Good (SCGCQ00784319)
- Fixed an issue where the firmware might hang during error handling of sense code 0b/47/xx (SCGCQ00701744)
- Fixed an issue where some SSDs may cause the system to hang at POST (SCGCQ00595506)
- Fixed an issue where an iMR RAID config may fail to import to 12gbps MR (SCGCQ00833765)
- Fixed an issue where R0, R5 and R6 read bandwidth dropped abruptly at 256K block size with 24drive SATA SSD config (SCGCQ00609808)
- Fixed an issue where RAID10 performance is under-performing (SCGCQ00794773)
- Fixed an issue where in some cases the LSI chip would convert an incoming chip reset to a system reset (SCGCQ00664261)
- Fixed an issue where many pRdm/pRequest/pReply messages would appear in LSI firmware log (SCGCQ00752195)
- Fixed an issue where when a consistency check is aborted, the adapter may reset (SCGCQ00819811)
- Fixed an issue where Patrol read does not start and gives incorrect warning message (SCGCQ00728404)
- Fixed an issue where the controller may reset unexpectedly during error handling (SCGCQ00825126)
- Fixed an issue where StorCLI may report Enclosure Not Found (SCGCQ00843146)
- Fixed an issue where x880 nodes may report excessive 'SCL STUCK Low! While I2C Rx Receiving Data' in LSI firmware log (SCGCQ00728935) (Retain TIP H213891)
- Fixed an issue where the command timeout for FED (SED) drives is too short, resulting in 05/2C codes (SCGCQ00797355)
- Fixed an issue where bandwidth falls as queue depth increases on R5/R6 24/40 drive SAS HDD configs at 256k block size (SCGCQ00701768)
- Fixed an issue where some SSDs may get bad PI CRC even though data is correct resulting in drive failure (SCGCQ00819314)
- Fixed an issue where the firmware may exposed more than 240VDs to host even if host driver doesn't support that many (SCGCQ00829214)
- Fixed an issue where MSM may display an error message if 'Schedule Consistency Check' is selected (SCGCQ00832908)
- Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives (SCGCQ00838953) (Retain TIP H214323)
- Fixed an issue where the MegaRAID POST may display "The native configuration is not supported by current firmware" (SCGCQ00812842)
- Fixed an issue where the EFI Driver Health Protocol will show Fail when more than 64VDs are configured (SCGCQ00830918)
- Fixed an issue where OS may BSOD when upgrading firmware on a controller the OS has booted from if Online Controller Reset is performed (SCGCQ00825725)
- Fixed an issue where controller wouldn't go to halt state after multibit ECC errors detected (SCGCQ00783186)
- Fixed an issue where Opal-compliant FDE (SED) drives were being marked as FDE/SED when they shouldn't be (SCGCQ00788250)
- Fixed an issue where correctable ECC error interrupts were being masked (SCGCQ00814997)
- Fixed an issue where reconstructed VDs were not being reflected in MSM until system reboot (SCGCQ00839018)
- Fixed an issue where controller commands may fail when an LD is deleted during reconstruction (SCGCQ00821693)
- Fixed an issue where firmware would go to MonTask when making VDs offline while a Rebuild is occuring under IO (SCGCQ00825775)
- Fixed an issue where commands to FDE (SED) drives may not respond within 500ms (SCGCQ00844445)
- Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00844447)
- Fixed an issue where HDD/SSD microcode updates may report fail even though they succeeded (SCGCQ00553252)
- Fixed an issue where slot numbers may be wrong systems with 32 drive slots (SCGCQ00529592)

Features and Enhancements
- Improved Jetstress / Exchange latencies (SCGCQ00717161)
- Added support for Learn Cycle debug commands in firmware (SCGCQ00814991)
- Added ability to clear the MaintainPdFailHistory (SCGCQ00474559)
- Improved drive rebuild performance (SCGCQ00427581)
- Improved Cache Offload error handling on read from the flash interface (SCGCQ00524419)
- Improved average latency and max latency in Windows operating systems (SCGCQ00671670)
- Implemented power throttling (SCGCQ00457280)
- Improved load balancing on >2 drive R1 VD of SSDs (SCGCQ00593588)
- Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490822)
- Added support for communicating with multiple controllers over I2C (SCGCQ00485924)
- Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00651680)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00399739)
- Improved accuracy of ROC temperature display (SCGCQ00575037)
- Increased range of priorities for background tasks, CC/PR/Rebuild/Migrate/BGI (SCGCQ00313882)
- Added support for 512e drives (SCGCQ00619363)
- Prevented a situation where there may be excessive overtemp warnings in the firmware log (SCGCQ00820067)
- Improved DDR3 signalinKg margin during heavy I/O workloads (SCGCQ00824711)
 
Version 24.2.1-0045 - Low Probability of Occurrence/Special Case
-------------------
Ehancement
 - Add support for onboard ServeRAID M1210e for Flex System x240 M5
   Compute Node
Fixes:
 - Fixed an issue where cache offload failured with pinned cache on R5 VD.
 - Fixed an issue where using upper case characters in command 'cli set securitykey' fails with error code '1001' and error message 'invalid key.'
 - Fixed an issue where system would not boot into legacy mode.
 - Fixed an issue where default setting of VD doesn't reflect MFC's setting.
 - Fixed an issue where Ccli show all command fails with error msg "Error! app exec failed in FW PCLIError! Internal."
 - Fixed an where ServeRAID M5210 showed the wrong slot numbers in both MR and iMR, in both HII and MSM.

Version 24.2.1-0027 - New Function Only/No fixes
-------------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

ThinkSystem RAID and ServeRAID M Series SAS/SATA Controller Driver for SLES 12



ThinkSystem RAID and ServeRAID M Series SAS/SATA Controller Driver for Linux

This product supports [SLES 12.2, SLES 12.1, & SLES 12.3,12.4]

Adapters Supported:
 - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller
  - ServeRAID M5210e SAS/SATA Controller for System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5215 SAS/SATA Controller (00JX142)
  - ServeRAID M5115 SAS/SATA Controller (90Y4390)
  - ServeRAID Lenovo Storage Expansion Node (65Y8588)
  - ServeRAID M5110 SAS/SATA Controller for Lenovo System x (81Y4481)
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)
  

NOTE TO SERVICE - Reference RETAIN #N/A

07.707.04.00-1 - Moderate Impact/Low Probability of Occurrence
--------------------------
MR 7.7 (new)

Defects:
- Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01514452)
- FW flash is not needed for driver.(SCGCQ01593539)
- Modified driver prints to dump relevant FW provided values(part of controller info structure) in syslog.(SCGCQ01626839)
- Merge upstream patch "Convert timers to use timer_setup" to in-house and support timer_setup API in 4.15 kernels.(SCGCQ01586787)
- MR7.7: scsi_dma_map() is called twice in IO path.(SCGCQ01619432)
- Driver is incorrectly deciding combined reply queue mode for SAS3.0 controller(SCGCQ01633318)
- Updated driver's file- "OS_Support_list_mr7.7.txt" with CMA support enablement and retpoline compliant driver binaries.(SCGCQ01760521)
- Renamed scratchpad registers from scratchpad0 , scratchpad1 etc ... in order to align with firmware naming convention.(SCGCQ01440031)
-(SCGCQ01664978)
- Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01440720 port of SCGCQ01430747)
- Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through.(SCGCQ01483730 port of SCGCQ01468189)
- XenServer 7.3 OS support- MR 7.6.(SCGCQ01594134 port of SCGCQ01554012)
- Divert FastPath IO with Chain frame to Firmware path.(SCGCQ01598186 port of SCGCQ01593175)
- expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01475068 port of SCGCQ01019663)
- Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through.(SCGCQ01542421 port of SCGCQ01468189)
- expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01542422 port of SCGCQ01019663)
- After a kill adpater, megasas_wait_for_adapter_operational waits for almost 360seconds before bailing out.(SCGCQ01619441 port of SCGCQ01615239)
- Setup IRQs only after Reply descriptors are allocated.(SCGCQ01542423 port of SCGCQ01506133)
- MR: Remove trace kernel RPMs from SUSE SLES11 SP4 driver iso images.(SCGCQ01594109 port of SCGCQ01563428)
- megasas_get_target_prop failing after OCR completed.(SCGCQ01619439 port of SCGCQ01607430)
- NVMe Task Management - Controller Reset Support (MegaRAID).(SCGCQ01592015 port of SCGCQ01545040)
- Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443432 port of SCGCQ01439776)
- Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01449786 port of SCGCQ01430747)
- Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01449816 port of SCGCQ01442784)
- Setup IRQs only after Reply descriptors are allocated.(SCGCQ01514459 port of SCGCQ01506133)
- Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01523087 port of SCGCQ01514452)
- Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01542419 port of SCGCQ01449957)

EnhancementRequests (23)
- Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01442784)
- Few officially unsupported PCI IDs are removed from MR7.7 driver code.(SCGCQ01598587)
- XenServer 7.4 OS support - MR 7.7.(SCGCQ01628129)
- Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01449957)
- Rebase inbox megaraid_sas driver to inhouse to reduce two different code base for maintenance.(SCGCQ01578030)
- MR_Aero: Create timer based thread in MR drivers to detect firmware FAULT.(SCGCQ01157766)
- Remove UpdateIoMetric and hence adapter level spinlock from IO path(SCGCQ01522127)
- Create cpu to msix table for kernel provided PCI_IRQ_AFFINITY (>=4.12 kernel).(SCGCQ01598134)
- OS driver support for Oracle Linux 7.5 - MR 7.7.(SCGCQ01586106)
- OS Driver Support for Ubuntu 18.04- MR 7.7.(SCGCQ01586128)
- Support RHEL7.5 GCA (3.10.0-862.el7.x86_64).(SCGCQ01586135)
- Early detection of faulty controller.(SCGCQ01599562)
- Change attribution language from Avago to Broadcom and update copyright end year.(SCGCQ01753095)
- Offload R5/R6 division to driver.(SCGCQ01513544)
- Update Linux Driver BST scripts and wrapper.(SCGCQ01529349)
- Marlin support is added to drivers.(SCGCQ01440724)
- Remove support for RHEL7.1, OEL7.2 and SLES12.(SCGCQ01449982)
- Optimize code around (raid context) in IO path.(SCGCQ01598187)
- Removed support of RHEL7.1, SLES12 and OEL7.2.(SCGCQ01600475)
- FW OCR Debug Mechanism - triggerSnapDump.(SCGCQ01520447)
- Set SLD bit in RAID map when "enableSLDOnAllRWIOs" is enabled.(SCGCQ01715619)
- Revert code changes related to iMR performance throttling.(SCGCQ01749962)
- Revert changes added in driver to divert FastPath IO with Chain frame.(SCGCQ01752939)


Version 07.705.04.00-5 - Moderate Impact/Low Probability of Occurrence

Defects (7)
- Provided driver workaround to reset __GFP_WAIT flag while allocating IO request frames.(SCGCQ01394892)
- Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01514452)
- Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver(SCGCQ01389431)
- Fixed few dev found and coverity reported defects(SCGCQ01392652)
- Selective stream detection logic in driver(SCGCQ01392643)
- During PCI remove, set unload flag after scsi_remove_host is called.(SCGCQ01392656)
- update LD map after populate drv_map, increase wait in IOCTL, fix index in error handling, rework in refiring DCMDs.(SCGCQ01415439)
- Added support for threaded interrupts.(SCGCQ01615015 port of SCGCQ01498747)
- Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through(SCGCQ01483730 port of SCGCQ01468189)
- Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01455132 port of SCGCQ01430747)
- MR: OEL 7.4 and 6.x x86_64 RPMs do not have the correct kernel versions.(SCGCQ01611888 port of SCGCQ01607445)
- expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01475068 port of SCGCQ01019663)
- Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01564604 port of SCGCQ01454090)
- Added NVME passthru support in MR linux driver.(SCGCQ01424605 port of SCGCQ01407028)
- Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01455206 port of SCGCQ01454090)
- Added NVME passthru support in MR linux driver.(SCGCQ01455135 port of SCGCQ01407028)
- Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443433 port of SCGCQ01439776)
- Setup IRQs only after Reply descriptors are allocated.(SCGCQ01514459 port of SCGCQ01506133)
- Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01449816 port of SCGCQ01449816)
- Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01449786 port of SCGCQ01430747)
- Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver.(SCGCQ01392672 port of SCGCQ01389431)


EnhancementRequests (10)
- MR7.4: Add SLES12 SP3 OS support.(SCGCQ01396756)
- Added support for RHEL7.4.(SCGCQ01455156)
- Added driver support for OEL7.4.(SCGCQ01396747)
- Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01449957)
- Added support for threaded interrupts.(SCGCQ01498747)
- MR7.4: OS driver support for RHEL 7.4.(SCGCQ01396738)
- Added support for SLES12 SP3.(SCGCQ01455167)
- Added driver binary support for Xenserver7.2.(SCGCQ01393249)
- Remove support for RHEL7.1, OEL7.2 and SLES12.(SCGCQ01449982)
- Removed support for few OS to align with OS support matrix policy.(SCGCQ01393194)


Version 7.703.07.00- Moderate Impact/Low Probability of Occurrence
---------------------
fixes:
- Send sense buffer upper 32bits inside IOC INIT frame.(SCGCQ01315987)
- MR: On OEL 6.x/7.x with UEK kernels - megaraid_sas.conf file from the kmod rpm does not match kernel version.(SCGCQ01319368)
- pass upper 32 bits of version buffer and system information buffer to FW inside IOC INIT frame.(SCGCQ01326366)
- Workaround changes for FW MFA frame pull issue.(SCGCQ01338087)
- Log dmesg if IOC INIT fails in IOMMU and RDPQ enabled enviornment for user information only.(SCGCQ01338097)
- Validated if any of DMA buffers pool which should be in same 4GB region does not cross 4GB boundary.(SCGCQ01338372)
- Memset to zero for MFI command frame for IOC INIT and use lower_32_bits() macro to get lower 32bits of DMA address passed to FW.(SCGCQ01341287)
- Removed Crusader ID(device ID- 0x0015) from supported PCI IDs of MR7.2 linux driver.(SCGCQ01350963)
- MR7.3: Code review defect - ioc_init_frame not freed during kernel module unload.(SCGCQ01384694)
- MR7.2: In megasas_issue_tm() SMID needs to be used for Task abort case only.(SCGCQ01315252)
- Incorrect processing of IOCTL frames for SMP/STP commands.(SCGCQ01383823)
- Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01298582)
- Removed print "Failed from megasas_complete_cmd" from PD CFQ sequence DCMD completion path.(SCGCQ01321565)
- Do not switch DMA mask to meet same 4gb requirement. IOMMU does not work well with such DMA mask switch.(SCGCQ01342578)
- Allocated MFI frame size and the size of MPT chain frame(Where MFI frame resides for MFI MPT passthru commands) should match.(SCGCQ01342650)
- Minimum possible value for module parameter- resetwaittime should be 1 secs instead of 0 secs.(SCGCQ01344137)
- Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver.(SCGCQ01389431)
- MR7.3: Data miscompare found with WB secure VD RAID 1 with LSA sending IOCTLs in parallel.(SCGCQ01378684)
- Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01381770 port of SCGCQ01298582)
- MR: On OEL 6.x/7.x with UEK kernels - megaraid_sas.conf file from the kmod rpm does not match kernel version.(SCGCQ01320324 port of SCGCQ01319368)
- Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01455132 port of SCGCQ01430747)
- Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01455206 port of SCGCQ01454090)
- Added NVME passthru support in MR linux driver.(SCGCQ01455135 port of SCGCQ01407028)
- Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443433 port of SCGCQ01439776)
- Minimum possible value for module parameter- resetwaittime should be 1 secs instead of 0 secs.(SCGCQ01344142 port of SCGCQ01344137)


EnhancementRequests:
- Added support for 64bit DMA mask for invader.(SCGCQ01294199)
- MR7.3: add support for Citrix XenServer 7.1 OS.(SCGCQ01257971)
- Send current time to FW during IOC init.(SCGCQ01307072)
- Added support for RHEL7.4.(SCGCQ01455156)
- MR7.3: add support for OEL 6.9.(SCGCQ01289005)
- Added support for threaded interrupts.(SCGCQ01498747)
- Added support for 64bit DMA.(SCGCQ01301940)
- Added support for SLES12 SP3.(SCGCQ01455167)



Version 7.702.06.00- Moderate Impact/Low Probability of Occurrence
---------------------
Defects (47)
 - Reset MPT frame field cmd_completed while retrurning it back to free pool.(SCGCQ01176530)
 - Optimized R1 FP write code.(SCGCQ01191077)
 - Before populating driver RAID map copy memset drv_map to zero and ldTgtIdtoLd array to 0xff(SCGCQ01204087)
 - Initialize stream detection array properly.(SCGCQ01204096)
 - On SPARC/Big endian host, need to convert peerSMID to little endian to CPU before accessing(SCGCQ01216698)
 - Fixed coverity reported issues and changed name of few functions.(SCGCQ01219231)
 - Don't set tm_capable for JBDO when PD CFG SEQ map is not available(SCGCQ01226222)
 - Remove local defination FALSE/TRUE and use OS provided false/true.(SCGCQ01256130)
 - Used vmalloc for crash dump buffers and driver's local RAID maps(SCGCQ01270059)
 - Reduce size of fusion_context allocation during driver load by moving load_balance_info array out, and try vmalloc if kmalloc fails.(SCGCQ01183280)
 - Flooding of messages- "BRCM: IO does not end on page boundary; sge_len" while running RAW IOs.(SCGCQ01189815)
 - Fixed data corruption by asking OS not to do merging of IOs to avoid SGE holes(SCGCQ01231229)
 - Code review defect: create separate function for allocating RAID maps(SCGCQ01282924)
 - Removed Crusader ID(device ID- 0x0015) from supported PCI IDs of MR7.2 linux driver(SCGCQ01350963)
 - Updated OS to send page aligned SGEs by calling blk_queue_virt_boundary(SCGCQ01206279)
 - Use vmalloc followed by memset to zero instead of vzalloc in driver code.(SCGCQ01206316)
 - MR_ValidateMapInfo issue on bigendian platform (In some case Detect Ghost VDs)(SCGCQ01213952)
 - Fixed code review defects(SCGCQ01254323)
 - Removed code inside macros VD_EXT_DEBUG, SPAN_DEBUG and enahnce prints in OCR path(SCGCQ01270056)
 - FW fault happens as driver wrongly fill numSGE=0.(SCGCQ01274103)
 - Code optimization and enhanced prints for debugging(SCGCQ01224881)
 - Remove unsupported PCI Device IDs from the driver code(SCGCQ01234256)
 
 - Resolved conflict of PCI device ID-0x0015(SCGCQ01254317)
 - MR7.2: In megasas_issue_tm() SMID needs to be used for Task abort case only(SCGCQ01315252)
 - Save interfaceType for each sysPDs inside SCSI device's private data field which will persists until sysPD is removed/deleted.(SCGCQ01216464)
 - Code Optimization and enhanced prints(SCGCQ01223300)
 
 - MR 7.1: Linux OS crash when powering off enclosure during I/O(SCGCQ01229442)
 - Return pending IOs with status DID_REQUEUE instead of DID_RESET to SCSU layer before doing OCR(SCGCQ01231846)
 - MR7.2: Port changes from upstream to make in-house MR 7.2 code to be consistent with upstream code(SCGCQ01282321)
 - Add print for partially copied SCSI IO and fix few endianness issues(SCGCQ01224305)
 - Linux Driver 07.700.23.00/Getting megaraid_sas prints during startup of OS(SCGCQ01255074)
 - aen class range check to avoid kernel panic(SCGCQ01256126)
 - Corrected bitmap macros inside struct RAID_CONTEXT35(SCGCQ01269453)
 - Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01298582)
 - Fix few dev found issues(SCGCQ01226224)
 - On OEL SPARC (Big Endian), Linux MR 7.1 driver loading fails to initialize Ventura which has RDPQ support enabled(SCGCQ01229897)
 - Fixed few code collab defects/comments(SCGCQ01202237)
 - Remove throttle IOs prints in IO path and add sysfs parameter to reflect number of R1 FP writes(SCGCQ01204099)
 - Ventura MR-7.0.1 RHEL 7.2 driver: ERR messages when installing driver 7.700.20.00(SCGCQ01222990)
 - Use do_div() kernel API to do modulo operation of 64 bit dividend and 32bit divisor .(SCGCQ01243263)
 - megasas_complete_cmd_dpc_fusion() will be called with 1 sec delay inside function megasas_wait_for_outstanding_fusion(SCGCQ01256116)
 - Allocated MFI frame size and the size of MPT chain frame(Where MFI frame resides for MFI MPT passthru commands) should match(SCGCQ01342650)

EnhancementRequests (17)
 - Big endian architecture is now support for Ventura generation of MR HBA.(SCGCQ01256016)
 - Fixed the problem of sync_irq not being called when MSI-x are disabled.(SCGCQ01206307)
 - Port changes from MR7.0 and MR6.13 critical fixes to MR7.1(SCGCQ01167939)
 - In megasas_build_ldio_fusion, code to set controller CPU affinity can be optimized(SCGCQ01216486)
 - Set device queue depth same as controller's can_queue for SCSI MQ mode(SCGCQ01271569)
 - Add SLES 11 32-bit build kit support to Ventura MR.(SCGCQ01214721)
 - Ported fixes from MR 6.13 to MR 7.1(SCGCQ01222522)
 - Added support for RHEL7.3(SCGCQ01224300)
 - Support SPARC/PPC/ARM (Big/Little Endian). Fix Endianess issue in MR Ventura driver.(SCGCQ01183275)
 - Added DCMD interface to read target properties for SCSI device(VDs and JBODs both)(SCGCQ01220142)
 - Added KMOD RPM support for OEL7.3 UEK.(SCGCQ01227476)
 - R1 Write IOPs improvement(SCGCQ01213232)
 - Extra code for bug in A0 ventura is removed. Optimized Descriptor write as Ventura required 32 bit in major IO Path operation.(SCGCQ01215347)
 - Remove Crusader device support from driver(SCGCQ01259175)
 - Don't re-issue Reset on the way back OCR(SCGCQ01215089)
 - Rework start_vm_build script used for VBAS build and new build infrastructure for DKMS RPMs(SCGCQ01261800)
-

Version 7.700.26.00- Moderate Impact/Low Probability of Occurrence
---------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.


Version 6.812.08.00 - Moderate Impact/Low Probability of Occurrence
---------------------
Fixes:
- Modified not to send outstanding IOs back to SML with DID_RESET host_byte but return IOs back with host_byte DID_REQUEUE before doing OCR. (SCGCQ01278656 Port Of Defect SCGCQ01231846)

Enhancement
- Added support for SLES 12.2


Version 6.812.07.00 - Moderate Impact/Low Probability of Occurrence
---------------------
Fixes
 - Changed timeout value for DCMDs get_bios_data and get_pd_info 180 seconds to keep it aligned with other DCMDs' timeout value. (SCGCQ00884247)
 - Do not allow MFI frame to be freed from DCMD fire context when already an OCR is in progress. (SCGCQ00879190)
 - Fixed an issue where driver always worked in non RDPQ mode even the running firmware did not support RDPQ. (SCGCQ00872542)
 - Moved SCSI layer interaction code out of reset_mutex in AEN thread to prevent deadlock around reset_mutex. (SCGCQ00868731)
 - Convert supported JBOD count value returned by firmware in CPU format and then use the same value for further validation (SCGCQ00837088)
 - Fixed an issue where unevenSpan configuration of R1 would not have proper load balancing for FP READ. SCGCQ00646224
 - Added timeout value for wait_event. (SCGCQ00249742)
 - Enabled hostlockless flag of SCSI host for RHEL6 and clones for async IO submission from SCSI mid layer. (SCGCQ00884242)
 - Fixed an issue where double freeing of MFI frame in case of MFI IO timeout in polled mode could occur. (SCGCQ00837932)
 - Added synchronization between OCR thread and AEN thread, so that there should not be any PCI write from AEN thread during OCR (SCGCQ00836410)
 - Added IO timeout value for SCSI management commands for JBOD. (SCGCQ00750452)
 - Fixed a JBOD performance issue due to incorrect MSI-x index set in request desc. (SCGCQ00619694)
 - Changed state machine of firmware crash dump collection to prevent file system on VD being set to Read-only mode after ECC error injection. (SCGCQ00608705)
 - Fixed an issue where incorrect messages such as LSI SAS2.0 were printed for MR driver. (SCGCQ00298201_
 - Fixed an issue where the driver sent an incorrect region type "REGION_LOCK_EXCLUSIVE" set to FW for RAID level >=5
 - Changed error handling for DCMD failure cases to allow graceful exit for not fatal errors. (SCGCQ00868661)
 - Free task management frame after dumping the task management reply frame data to ensure that TM reply frame will have valid data returned by firmware. (SCGCQ00860038)
 - Release reset_mutex inside OCR function, if adapter is already killed to prevent a kernel panic. (SCGCQ00857740)
 - Increased timeout to 180 seconds for flush cache and shutdown controller DCMDs to prevent kernel panic when DCMDs fired during driver's shutdown. (SCGCQ00841491)
 - Fixed an issue where traversed LDs at multiple places up to maximum 256 were limited to 64. (SCGCQ00652795)
  - Fixed an issue where the driver crashed when msix_disable=1 was passed to the boot time parameter. (SCGCQ00383508)
 - Fixed an issue where kernel panic seen while deleting VD and background IOs running. (SCGCQ00803468)
 - Fixed an issue where the driver was not sending DCMD- MR_DCMD_CTRL_SET_CRASH_DUMP_PARAMS after OCR. (SCGCQ00601138)
 - Fixed an issue where the kernel panicked inside PCI subsystem because of IRQs not freed before disabling MSI-X interrupts (SCGCQ00827403)
 - Disabled SED drive JBOD support. (SCGCQ00751296)
 - Fixed multiple OCRs triggering hits Exception Core issue (SCGCQ00707592)
- Fixed an issue where the firmware faulted due to invalid regionlock Flags set by Driver. (SCGCQ00796461)
- Fixed an issue where subsequent reads of state value from hardware resulted different values and could lead to a timeout in and a non working adapter. (SCGCQ00709216)
- Fixed an issue where Offline VD caused boot hangs in SLES 11 (SCGCQ00284564)
 - Disabled SPAN_DEBUG and set get_arm_from_strip to print if firmware supports UnevenSpan. (SCGCQ00365846)
 - Added check to validate ldcount exposed in firmware RAID map for legacy firmware.  If ldcount is more than 64, fail RAID map validation. (SCGCQ00820349)
 - Fixed an issue where the Linux kernel crashed when AEN and LD Sync commands were issued frequently. (SCGCQ00712031)
 - Fixed an issue where duplicate disk(s) were seen on controller after loading Linux driver during OS installation, (SCGCQ00568992)
 - Fixed an issue where kernel panic could occur at driver load time on 3.0 kernels (i.e. SLES11 SP2, SLES11SP3). (SCGCQ00561505)
 - Changed driver to return SCSI command back to mid layer if the controller has any critical hardware errors. SCGCQ00362023
 - Fixed an issue where the driver did not do Load balance for R1 READ due to wrong stats counters. (SCGCQ00677516 Port of Defect - SCGCQ00674872)
 - Fixed potential duplicate IOCinit frames being fired by VMware5 VF driver during OCR. (SCGCQ00571967 PORT OF SCGCQ00571679)
 - Fixed OS crash issue on SCSI IO timeout (SCGCQ00631210 PORT OF SCGCQ00625137)
 -Fixed an issue where the kernel panicked due to MFI/MPT pass-through command timeout and later finished from Interrupt context. (SCGCQ00307867 PORT OF - SCGCQ00302080)
 - Fixed an issue where megasas_poll_wait_aen was cleared before poll syscall returns causing to lose events (SCGCQ00575192 PORT OF SCGCQ00574787)
 -Fixed an issue where data corruption observed on JBODs while running IOs with 32k block size. (SCGCQ00530992 PORT OF SCGCQ00523780)
 - Fixed MPC kernel panic during chassis power cycle if AEN completes and detach is called before event workqueue runs. (SCGCQ00647390 PORT OF SCGCQ00645836)
 - Fixed an issue where kernel crashed in some cases, where megaraid_sas driver is loaded but controller is not present. (SCGCQ00282968 PORT OF SCGCQ00282067)


Enhancements:  
 - Set queue depth for syspD based on interface type (SCGCQ00879700)
 - Updated module Meta data (module description and module author) with Avago replacing LSI. (SCGCQ00801961)
 - Set OS provided timeout value for sysPD non read-write IOs (SCGCQ00764795)
 - Performance tuning for SMP affinity is implemented for distros's which support irq_set_affinity_hint API. (SCGCQ00623697)
 - Optimized OCR path to enable interrupt and make HBA OPERATIONAL after driver has fired LD_MAP_GET_INFO DCMD. (SCGCQ00768402)
 - Added module parameter to turn on/off SMP affinity code. (SCGCQ00666706)
 - Driver will do load balance for N Drive Raid 1 volumes. (SCGCQ00634064)
 -Functionality in driver is added to differentiate between iMR and MR at firmware initialization time. (SCGCQ00361244)
 - Uneven Span support added in Driver. (SCGCQ00319104)
 - Driver code is updated such way that it can work for any block size drive, if the rest of the system has proper support for the same. (SCGCQ00259244)
 - Implemented online controller reset if controller is not responding at driver load time. (SCGCQ00820389)
 - Added SCSI residual bytes support to the megaraid_sas Linux driver (SCGCQ00347089)
 - Use sequence number for JBOD FastPath I/Os to eliminate command block after drive replacement (SCGCQ00806534)
 - Big endian architecture support added for MR Linux driver (SCGCQ00526911)
 -  Driver support is added for 3108 C0 chip combine reply queue ON (SCGCQ00354586)
 - Added support 240 VD feature (SCGCQ00622703)
 - Added Firmware crash dump collection support (SCGCQ00550369)
 - Added support for large I/O 1MB transfer size (SCGCQ00816313)
 - Changed the max sg table size to 64. Old setting was 70 (SCGCQ00653992)
 - Added driver support for task management for Jbod or VD (tmCapable) (SCGCQ00854635)
 - Added support for SED JBOD in MR Linux driver (SCGCQ00711555)
 - Changed code to complete IOCtls posted just before a kill adapter so user space applications do not hang. (SCGCQ00759916)


Version 6.810.09.00 - Moderate Impact/Low Probability of Occurrence
---------------------
 Fixes:

 - Fixed an issue where deadlock may occur when the Automatic Event Notification thread runs in parallel with error handler thread (SCGCQ00911332, Port of SCGCQ00868731)

 - Fixed an issue where driver will operated in RDPQ mode regardless of whether firmware has advertised support or not (SCGCQ00872542)

 - Fixed an issue where system may reset with error "BUG: unable to handle kernel NULL pointer dereference at 00000000000000d0" preceded by error "megasas: target reset FAILED!!" (SCGCQ00875223)

 - Fixed an issue where driver MFI frames could be freed twice (SCGCQ00879190)

 - Fixed an issue where some out-of-band commands had different timeouts than others (SCGCQ00884247)

 - Fixed an issue where performance was lower on async IO submissions from the SCSI mid layer (SCGCQ00884242)

 - Fixed an issue where a kernel panic may occur if the system is reset or fail to reboot (SCGCQ00859634, Port of SCGCQ00857740)

 - Fixed an issue where Task Management frames were not being dumped after the Tast Management Reply frame data (SCGCQ00860038)

 - Fixed an issue where a fatal error may occur when an out-of-band command times out during an Online Controller Reset (SCGCQ00882011, Port of SCGCQ00868661)

 - Fixed an issue where kernel may hang when many commands are timing out or many Automatic Event Notifications are being processed (SCGCQ00857245)

 - Fixed an issue where megaraid_sas module was not being included inside initrd/initramfs (SCGCQ00880965)

 - Fixed an issue where kernel may panic if driver does not setup IRQs for non-MSI-x interrupt mode (SCGCQ00870263, Port of SCGCQ00867873)

 - Fixed an issue where driver return code is based on command completion rather than command return code (SCGCQ00856103, Port of SCGCQ00856089)

 - Fixed an issue where Tape drives may not be detected by the Operating System (SCGCQ00914385, Port of SCGCQ00911702)

 - Fixed an issue where max_sectors per IO request may be set to more than firmware can handle (SCGCQ00917992, Port of SCGCQ00917399)
 
- Fixed an issue where an IERR may occurr on heavy IO with Failover (SCGCQ00864111, Port of SCGCQ00736612)
 
 
Enhancements:

 - Enhanced queue depths in driver for physical disks based on interface type (SCGCQ00879700)

 - Improved naming of internal functions (SCGCQ00866064)

 - Updated module parameter "rdpq_enable" default to "1" (enable RQPQ mode) (SCGCQ00871565)

 - Enhanced reply queue to support queue depth greater than 1K (SCGCQ00853521)

 - Added feature for driver to support Task Management for JBOD and Virtual Drives (SCGCQ00854635)

 - Added module parameter to disable 1M IO support and set default to enable 1M IO support (SCGCQ00911362)

 - Enhanced tasklet initialization so it would occur before setting up IRQs (SCGCQ00914393, Port of SCGCQ00911709)

 - Simplified HB handling for SR-IOV (SCGCQ00864113, Port of SCGCQ00700580)

 - Enhanced driver to update Online Controller Reset capability when it changes (SCGCQ00914389, Port of SCGCQ00908352)

 - Added feature to print Critical, Fatal and Dead firmware events into system logs (SCGCQ00868723, SCGCQ00882010, Port of SCGCQ00866176)

 - Enhanced HB handling to align with behavior on other Operating Systems (SCGCQ00864117, Port of SCGCQ00707323)

 - Removed excess dead code (SCGCQ00850012)

Version 6.808.16.00 - Moderate Impact/Low Probability of Occurrence
---------------------
Fixes:
- Fixed an issue where a deadlock may occur around reset_mutex when Automatic Event Notification threads run in parallel with error handlers - (SCGCQ00911332, Port of SCGCQ00868731)
- Fixed an issue where scanning of Tape drives does not occur depending on whether the drive state is set to systemPD or not - (SCGCQ00914385, Port of SCGCQ00911702)
- Fixed an issue where max_sectors may be set larger than what firmware can support - (SCGCQ00917992, Port of SCGCQ00917399)
- Fixed an issue where kernel may panic due to driver not setting up IRQs for non MSI-x interrupt mode - (SCGCQ00870263, Port of SCGCQ00867873)
- Fixed an issue where driver may halt firmware due to improper error handling for DCMD failure cases - (SCGCQ00882011, Port of SCGCQ00868661)
- Fixed an issue where driver may hang kernel due to deadlock - (SCGCQ00857245)
- Fixed an issue where system may crash due to timeout for flushing cache and shutting down controller DCMDs was not long enough - (SCGCQ00841491)
- Fixed an issue where deadlock may occur between Online Controller Reset and Automatic Event Notification processing function - (SCGCQ00846933)
- Fixed an issue where PCI writes from Automatic Event Notification thread were occurring during Online Controller Reset - (SCGCQ00836410)
- Fixed an issue where MFI frames linked list may corrupt due to double-freeing of frame in the case of an MFI IO timeout - (SCGCQ00837932)
- Fixed an issue where kernel may panic inside PCI subsystem due to IRQs not freed before disabling MSI-X interrupts - (SCGCQ00827403)
- Fixed an issue where ldcount was not validated for non-240VD firmware - (SCGCQ00820349)
- Fixed an issue where a command block would occur for JBODs with FastPath IOs after a drive is replaced - (SCGCQ00806534)
- Fixed an issue where 1MB IO support was not supported controller-wide - (SCGCQ00816313)

Enhancements:
- Set DMA alignment to 8 bytes for PI-enabled VDs - (SCGCQ00928796, Port of SCGCQ00928176)
- Added a parameter to support disabling 1MB IO support - (SCGCQ00911362)
- Added support for printing Critical, Fatal and Dead Firmware events into system logs - (SCGCQ00882010, Port of SCGCQ00866176)
- Added support for driver to perform an Online Controller Reset at driver load time if the controller is not responding - (SCGCQ00820389)

Version 6.808.14.00 - Moderate Impact/Low Probability of Occurrence
---------------------
Fixes
- Fixed an issue where controller may reset or "MonTask: line 1276" error will occur with JBOD present (SCGCQ00837088)
- Fixed a performance issue on RAID1 with 256k IO size (SCGCQ00674872)
- Fixed a performance issue on RAID1 reads with FastPath enabled (SCGCQ00646224)
- Fixed an issue where an Online Controller Reset may take an unusually lon time (SCGCQ00420374)
- Fixed an issue where a controller firmware crash may not be recognized by driver (SCGCQ00249742)
- Fixed an issue where an MFI frame may be freed twice on MFI command timeout (SCGCQ00837932)
- Fixed an issue where the firmware may fault in an Automatic Event Notification fires during an Online Controller Reset before the chip is in READY state (SCGCQ00836410)
- Fixed an issue where there was no IO timeout value for SCSI management commands for Secure JBOD (SCGCQ00750452)
- Fixed a performance issue on SSDs in JBOD mode (SCGCQ00619694)
- Fixed an issue where file system on a VD can go to read-only on ECC error detection (SCGCQ00608705)
- Fixed an issue where disks may not be found during installation after loading the driver (SCGCQ00299643)
- Fixed an issue where a kernel panic may occur when cable pulled during system reboot (SCGCQ00841491)
- Fixed an issue where 240VD support was not fully implemented (SCGCQ00652795)
- Fixed an issue where the driver may crash if msix_disable=1 is passed to kernel as boot parameter (SCGCQ00383508)
- Fixed an issue where IO errors may occur when connected to a Tape drive (SCGCQ00399947)
- Fixed an issue where kernel may hang due to megaraid_sas driver deadlock (SCGCQ00857245)
- Fixed an issue where kernel may panic when deleting VD and background IO is occurring (SCGCQ00803468)
- Fixed an issue where crash dump may be disabled after an Online Controller Reset (SCGCQ00601138)
- Fixed an issue in 32bit OSs where driver may not load on boot (SCGCQ00362423)
- Fixed an issue where deadlock may occur (SCGCQ00846933)
- Fixed an issue where a kernel panic may occur because IRQs are not freed before disabling MSI-X interrupts (SCGCQ00827403)
- Fixed an issue where multiple Online Controller Resets can trigger a Core Exception (SCGCQ00707592)
- Fixed an issue where crash dump may not be performed properly (SCGCQ00593374)
- Fixed an issue where firmware may fault with CacheCade (SCGCQ00796461)
- Fixed an issue where adapter may hang (SCGCQ00709216)
- Fixed an issue where an offline VD may cause boot hangs (SCGCQ00284564)
- Fixed an issue where kernel may panic (SCGCQ00820349)
- Fixed an issue where kernel may crash in megaraid_sas driver with CacheCade if there are many Automatic Event Notifications and LD sync operations occurring (SCGCQ00712031)
- Fixed an issue where system may hang with CacheCade (SCGCQ00687881)
- Fixed an issue where the same disk may show multiple times in OS (SCGCQ00568992)
- Fixed an issue where kernel may panic on Linux kernels version 3.0 or greater (SCGCQ00561505)
- Fixed an issue where invalid IO statistics may be provided if driver supports more than just 512b sector drives (SCGCQ00282615)
- Fixed an issue where driver fails to reboot system due to outstanding IOs in SCSI mid-layer when controller is in error state (SCGCQ00362023)

Enhancements
- Added ability for JBOD IOs going via firmware path to use timeout value provided by OS (SCGCQ00764795)
- Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00712510)
- Added support for 4k sector drives if the system supports it (SCGCQ00259244)
- Added support for driver to perform an Online Controller Reset if the controller is not responding (SCGCQ00820389)
- Fixed an issue where system may hang on S3 resume (SCGCQ00758933)
- Added a feature to prevent command block with FastPath after JBOD drive replacement (SCGCQ00806534)
- Enhanced 1MB IO support (SCGCQ00816313)
- Added support for "megaraid_sas.disable_ext_io=1" boot parameter to disable 1M IO support (SCGCQ00911362)
- Added support for Secure JBOD (SCGCQ00711555, SCGCQ00753765)
- Fixed an issue where user space applications may hang if IOCtl is sent prior a kill adapter issued (SCGCQ00759916)
- Fixed an issue where OS may crash on a SCSI IO timeout (SCGCQ00631210)
- Fixed an issue where system may fail to reboot or will kernel panic on init 6 if controller has faulted (SCGCQ00859634)
- Fixed an issue where firmware may fault (SCGCQ00702536)
- Fixed an issue where controller may crash during system power cycle (SCGCQ00647390)
- Fixed an issue where kernel may crash when megaraid_sas driver is loaded but no MegaRAID controllers are present (SCGCQ00282968)



Version 6.806.09.00 - New Function Only/No fixes
-------------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

LSI Storage Authority Software for windows and linux



LSI Storage Authority Software

Supported controllers:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 4GB Cache PCIe 12Gb Adapter  
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - N2226 SAS/SATA HBA for Lenovo System x (00AE916)
  - N2225 SAS/SATA HBA for Lenovo System x (00AE912)	 
  - N2215 SAS/SATA HBA for Lenovo System x (47C8676)
  - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110)
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210 SAS/SATA Controller
Supported Operating Systems:
 - SLES 11 SP3/SP4, SLES 12/SP1/SP2/SP3/SP4,SLES 15
 - RHEL 6.7/6.8/6.9/7.1/7.2/7.3/7.4/7.5/7.6
 - Vmware  ESXi  6.5 U1,U2
 - Vmware ESXi ESXi 6.0 U1/U2/U3
 - Vmware ESXi 6.7

NOTE TO SERVICE - Reference RETAIN #N/A

004.189.000.000 - Moderate Impact
---------------

-(SCGCQ01351380) 
 - WG: Physical Drives tab should be aligned in center for Advanced Configuration.(SCGCQ01440777) 
 - Fixed: settings in configuration service API is inconsistent with other applciations(SCGCQ01518134) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01534444) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01539326) 
 - LSA Client 7.6: SPAN drives order is not maintained(SCGCQ01539355) 
 - Client: LSA should handle the not empty check for enclousre field for the physicalDevices response(SCGCQ01555968) 
 - IT-FURY-PH16:LSA-4.126.0.0-Fully Populated Enclosure S/N is "NA" and shown correctly after few drive removals.(SCGCQ01563352) 
 - SCGCQ01565134: IT-Ventura-PH7:LSA-4.126.0.0- FW update fails with error "File size Exceeds 16MB".(SCGCQ01565134) 
 - WG : Server detail is getting populated twice when user is using local IP (127.0.0.1(SCGCQ01565327) 
 - WG: During VD Creation on Simple Configuration, Clicking more than Once on the Finish Button is giving a Wrong Message.(SCGCQ01569262) 
 - WG: Copyright info is shown as 2017 instead of 2018(SCGCQ01571088) 
 - WG:Pop Up scroll missing in case there are more number of VDs to add while setting patrol read properties & Schedule CC(SCGCQ01571089) 
 - WG: User is notified to that multiselect PD/VD displays the properties but it is not supported(SCGCQ01571095) 
 - IT-FURY-PH16:LSA-SATA NCQ bit is always shown as disabled(SCGCQ01571261) 
 - LSA is not responding if online state is changed to offline(SCGCQ01571453) 
 - SCGCQ01571863: WG: LSA installation/uninstallation on linux does not notify the user on success or failure(SCGCQ01571863) 
 - Fixed: Windows OS details were reported as VMware details in Manual Search(SCGCQ01571874) 
 - WG: LSA wrapper indicates the progress of operations appears to be clickable while there is nothing user can select from list(SCGCQ01573087) 
 - SCGCQ01575706: WG:LSA installation exits on invalid option for selecting range of LSA events, it asks for retry with options listed again(SCGCQ01575706) 
 - SCGCQ01575999: FURY-PH16:LSA-Model Number is getting truncated for ST3000DM001,Hitachi HDS723020BLA642 models.(SCGCQ01575999) 
 - WG: the string 'status' is displayed multiple times after searching the server for manual addition(SCGCQ01577707) 
 - WG: LSA allows to replace HDD missing drive with SSD UG drive, fails with Partial Success.0 Successful;1 Failed notification(SCGCQ01577769) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01578248) 
 - LSA Server: Removal of Additional Carriage Returns and Line feeds in tty log file(SCGCQ01579290) 
 - WG: Error message on a failed VD creation is displayed outside the allocated space(SCGCQ01586721) 
 - SCGCQ01588880:(SCGCQ01588880) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01590450) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01595641) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01601386) 
 -(SCGCQ01628332) 
 - fixed: Advanced Configuration is grayed out when there are 2 jbods available in the system.(SCGCQ01631267) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01669558) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01675460) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01681070) 
 - WG: LSA 7.7 PA2 Not able to create RAID 00 VDs on iMR Ventura controller(SCGCQ01683638) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01683938) 
 - During migration from r0(opal drives and non-secured) to r1, Add Pd list does not list the available drives (Greater/same si(SCGCQ01687072) 
 - WG: Issues pertaining to searching of the server : manual discovery in list view & GUI issues in the manual discovery panel(SCGCQ01687117) 
 - MR7.7_LSA: Unable to convert JBOD to UG when filesystem is present(SCGCQ01697980) 
 - LSA Linux doesn't have latest storelib(SCGCQ01713580) 
 - WG MR 7.7 PA2: LSA allows to add FDE and OPAL drives to create Encrypted volume(SCGCQ01721222) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01761801) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01761830) 
 - Fixed: nvme is allowed to mix with sas /sata(SCGCQ01762948) 
 - SCGCQ01763132: LSA: Alert Configuration response contains unsupported character(SCGCQ01763132) 
 - Foreign Config preview should show the VD details also(SCGCQ01788639) 
 - LSA Opal: RLM mixing for Opal SSC and Enterprise shouldn't be allowed when enableFDETypeMix=0(SCGCQ01790063) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) 
 - compilation error in server(SCGCQ01817434) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01841473) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856350) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - WG: LSA shows incorrect popups while making the drive from offline to online & vice versa(SCGCQ01922610) 
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01937406) 
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971368) 
 -(SCGCQ01542415) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01552654) 
 - Correcting the library version display, ini file contents and also the readme files contents.(SCGCQ01561849) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01564526) 
 - SWR: Device ID is not displayed in LSA.(SCGCQ01564621) 
 - MR/IR: Controller Device ID value mismatch in LSA(SCGCQ01564622) 
 - WG:LSA and web server port have references of SLIM and nignx in notification if invalid ports are given during LSA installatn(SCGCQ01571099) 
 - WG: Issues pertaining to replace drive confirmation popup(SCGCQ01573101) 
 - Security related information should not be displayed in IR/IT for LSA(SCGCQ01577891) 
 - LSA allows user to assgin a 512 B drive as replacement to 4k missing drive in a DG(SCGCQ01591175) 
 - SCGCQ01593058: Add non printable character support for sata pd product id display(SCGCQ01593058) 
 - Add a provision to indicate VMware/NonVmware server in Manual Discovery Panel(SCGCQ01600706) 
 - LSA WG FURY IT: UEFI image download is failing in LSA(SCGCQ01616545) 
 - LSA 7.6 Server: LSA is showing the option for PD:"Undo Prepare For Removal", when the DG is in TR state(SCGCQ01618243) 
 - Not able to create secure VD with latest MR 7.7 LSA 177.000.000-SCGCQ01664972 but OK with previous version(SCGCQ01665121) 
 - Error observed while adding Windows gateway server in through manual discovery(SCGCQ01675601) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01677101) 
 - LSA MR7.7 PA2: Previously cleared configuration is seen in presence of OPAL foreign drive in Jbod Mode.(SCGCQ01685488) 
 - WG MR7.7 PA2:Once the 69639 error code is seen in LSA, performing every valid operation fails until manual refresh is perfo(SCGCQ01686013) 
 - WG MR 7.7:There is no import option for GHS Foreign device in LSA(SCGCQ01698105) 
 - Fixed: LSA handle count increase was observed(SCGCQ01713154) 
 - Add physical Drives page is not consistent across (Advanced Configuration and Modify drive Group(SCGCQ01716606) 
 - LSA: Handle Opal drive scenario for Hotspare and replace drive(SCGCQ01719043) 
 - LSA client: Add support to show incompatible profiles details(SCGCQ01727270) 
 - Add SCSI Unmap property at PD level(SCGCQ01732785) 
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01745770) 
 - WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile(SCGCQ01747490) 
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline.(SCGCQ01752969) 
 - [CISCO][TR]"Clear Transport Ready" option on rebuild LD should be removed or greyed out in LSA(SCGCQ01753229) 
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01761269) 
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01763742) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813078) 
 - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01833469) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01838943) 
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01886563) 
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01918692) 
 -(SCGCQ01534450) 
 - LSA needs to change "Error code" : 86017, Description:Operation failed because of a resource reservation error" to proper mes(SCGCQ01556013) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01581943) 
 - SCGCQ01582139: MR7.6_LSA: Enclosure ID and Device ID is shown blank in LSA event logs(SCGCQ01582139) 
 - WG: LSA Page auto scrolls down with scheduler wrapper going out of focus. LSA page would now be only half transparent(SCGCQ01586697) 
 - PH7 LSA WG Ventura: Sorting the drives on the basis of Device ID is not working fine(SCGCQ01587630) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01593855) 
 - WG: Instance validation failed for controller GET(SCGCQ01601458) 
 - WG: Minor text changes to be made in user information when no rows are selected in PD tab / DG tab / other hardware tab(SCGCQ01601656) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01615856) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01638193) 
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress(SCGCQ01680714) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01685449) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01686024) 
 - Instant Secure Erase does not work in VMware when schedule is enabled(SCGCQ01686028) 
 - MR7.7_LSA: Error code:0 is observed when driver security is changed in LSA(SCGCQ01686050) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716622) 
 - fixed: max pd is a bigger number than the actual allowed max pd per raid level(SCGCQ01746200) 
 - WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection(SCGCQ01764794) 
 - WG: gateway system is not discovering systems with different web port number in remote discovery page.(SCGCQ01788630) 
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives)(SCGCQ01803743) 
 - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01809413) 
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) 
 - fixed: Info "1920 more drives can be added" need to change in LSA(SCGCQ01827401) 
 - The display wrong location in page(SCGCQ01836732) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01355833) 
 - WG: Changing the drive security key with invalid authentication key results in notification that is not in format(SCGCQ01573090) 
 - WG: Raid 00 DG having missing drives Span list dissapears when user tries to sort the drives based on capacity(SCGCQ01577833) 
 - MR 7.7: LSA did not allow to pick all SED/FDE but OK to pick one by one when create secure VD(SCGCQ01629062) 
 - SCGCQ01718994: LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01718994) 
 - When there is pending personality, do not allow behavior Mode change, GUI refresh issue(SCGCQ01731312) 
 - Assign DHS is not showing any message in failure case(SCGCQ01732485) 
 - To enable the Alarm user has to click on the bottom of checkbox(SCGCQ01740783) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01818960) 
 - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives(SCGCQ01850008) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) 
 - LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01533554) 
 - WG: change Behavior Mode From JBOD to None is Not Working until closing the window(SCGCQ01635541) 
 - WG MR7.7PA2:In Jbod mode after first reboot and after converting Jbod to UG, advance configuraton leads to Jbod table.(SCGCQ01683001) 
 - MR 7.7 PA2: LSA does not refresh DG icon when PDs are made offline to online and visa versa.(SCGCQ01686029) 
 - WG MR 7.7 PA2:Encrypted Opal drive VD supports the Opal drive replacement with FDE drive(SCGCQ01697265) 
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button(SCGCQ01737550) 
 - MR 7.7 alpha: LSA displays raid 1 as raid 1E when created using 4 drives.(SCGCQ01764771) 
 - SCGCQ01564386: IT-FURY-PH16:Drives are not listed under Enclosures ( "0" drives) under other Hardware if connected in Multipath.(SCGCQ01564386) 
 - Coverity Defect fix in 7.7 Stream(SCGCQ01682365) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01714415) 
 - Client changes for defect SCGCQ01629703(SCGCQ01714659) 
 - MR7.7_LSA: After disabling PR, PR properties shows next scheduled time(SCGCQ01718119) 
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG(SCGCQ01803722) 
 - LSA is not locating all drives correctly(SCGCQ01924674) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01515496) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01563343) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01629574) 
 - Fixed: Show Advanced Config menu only if Unconfigured UG is present(SCGCQ01629703) 
 - WG: Readme shows wrong Version of LSA in html\files\LSA_ReadMe\LSA_Readme(SCGCQ01822525) 
 - SCGCQ01822561: WG: Changed LSA port is not listed after Direct agent installation on Rhel(SCGCQ01822561) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01866289) 
 - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01564627 port of SCGCQ01542412) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01564633 port of SCGCQ01562368) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01564739 port of SCGCQ01545262) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01564943 port of SCGCQ01534444) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565025 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01565116 port of SCGCQ01555955) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01566088 port of SCGCQ01562368) 
 - WG: No success or failure notification is shown on enabling the JBOD drive security(SCGCQ01566435 port of SCGCQ01511274) 
 - SCGCQ01545384: Installation of LSA with LWM option is showing installation_type = 0, in the LSA.conf file(SCGCQ01567110 port of SCGCQ01545384) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569267 port of SCGCQ01504080) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01569465 port of SCGCQ01542412) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01569474 port of SCGCQ01539349) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01569949 port of SCGCQ01563340) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01570203 port of SCGCQ01550970) 
 - Enclosure's physicaldevices URI getting failed with 405 error(SCGCQ01589492 port of SCGCQ01523122) 
 - Label of the user menu drop down should change reinforcing that selection worked.(SCGCQ01597876 port of SCGCQ01493942) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01599402 port of SCGCQ01563340) 
 - Version changes for LSA 4.129 common project(SCGCQ01601148 port of SCGCQ01601146) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601603 port of SCGCQ01598515) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01604992 port of SCGCQ01564526) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01605344 port of SCGCQ01581943) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01609343 port of SCGCQ01578248) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01614982 port of SCGCQ01355833) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01616555 port of SCGCQ01595641) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01617930 port of SCGCQ01401460) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01628354 port of SCGCQ01504080) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01634072 port of SCGCQ01473733) 
 - WG: few of the alert params have the missing controller ID tag for the events(SCGCQ01635756 port of SCGCQ01625923) 
 - LSAServer: Use scheduler call for heavy operations for performance improvement - PD Operations(SCGCQ01635765 port of SCGCQ01514283) 
 - WG: though the hotspare button will be disabled after adding VD for a Raid 1 DG, the hand cursor button appears(SCGCQ01635778 port of SCGCQ01626738) 
 -(SCGCQ01639457 port of SCGCQ01599526) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01685343 port of SCGCQ01641760) 
 - Raid 1 Volume creation using 4 drives is displayed as Raid 1E(SCGCQ01686231 port of SCGCQ01686106) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687172 port of SCGCQ01686080) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01697468 port of SCGCQ01683941) 
 - LSA fails to flash GPMR2 package 50.1.0-1048 on top of MR 7.6 package 50.6.0-1255 on first try-it is successful on 2nd try(SCGCQ01697485 port of SCGCQ01680521) 
 - LSA not showing the proper time stamp in the schedule PR page(SCGCQ01698028 port of SCGCQ01677008) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01719179 port of SCGCQ01515496) 
 -(SCGCQ01733306 port of SCGCQ01721811) 
 - Fixed: LSA handle count increase was observed(SCGCQ01742153 port of SCGCQ01713154) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01747012 port of SCGCQ01745768) 
 - Server schema validation is failing(SCGCQ01764913 port of SCGCQ01619401) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01764928 port of SCGCQ01638193) 
 - LSA installation failed on SLES15(SCGCQ01784699 port of SCGCQ01760620) 
 - LSA needs proper message for max config import(SCGCQ01789100 port of SCGCQ01763411) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) 
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup(SCGCQ01810649 port of SCGCQ01803341) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813086 port of SCGCQ01813078) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01816649 port of SCGCQ01686080) 
 - C480-M5: LSA downloaded event log needs better decoding(SCGCQ01828830 port of SCGCQ01321211) 
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) 
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab(SCGCQ01851980 port of SCGCQ01851906) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01897266 port of SCGCQ01818960) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01901774 port of SCGCQ01866289) 
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915861 port of SCGCQ01905192) 
 - [CISCO]LSA shows previously set security key (M3g@raid(SCGCQ01921581 port of SCGCQ01878346) 
 - LSA fails to start initialization on EPD if it has DDF(SCGCQ01921583 port of SCGCQ01849522) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) 
 -(SCGCQ01921684 port of SCGCQ01841361) 
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event(SCGCQ01921836 port of SCGCQ01876230) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01538488 port of SCGCQ01473733) 
 -(SCGCQ01564591 port of SCGCQ01515389) 
 - WG: System display uniformity is not there in GUI (Remote server discovery(SCGCQ01567177 port of SCGCQ01553588) 
 - Client: Handle Enable/Disable style for search Button(SCGCQ01567216 port of SCGCQ01539573) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01567307 port of SCGCQ01545262) 
 - Manual discovery of servers(SCGCQ01569264 port of SCGCQ01539471) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569569 port of SCGCQ01504080) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01570076 port of SCGCQ01563340) 
 - Converting the JBOD Pds to Unconfigured good PD during VD creation VD creation(SCGCQ01597581 port of SCGCQ01518204) 
 - Manual discovery of servers(SCGCQ01600837 port of SCGCQ01539471) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01615020 port of SCGCQ01552654) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01615042 port of SCGCQ01601386) 
 -(SCGCQ01633836 port of SCGCQ01599526) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01635183 port of SCGCQ01593855) 
 - Use schedular call for heavy operations for performance imporvement(SCGCQ01635665 port of SCGCQ01506032) 
 - Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01635761 port of SCGCQ01518113) 
 - JBOD Mode : WG: Even after clicking Convert JBOD the JBOD conversion page does not refresh with updated list(SCGCQ01635784 port of SCGCQ01617721) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676612 port of SCGCQ01670094) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676732 port of SCGCQ01670094) 
 -(SCGCQ01685548 port of SCGCQ01685009) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01686054 port of SCGCQ01685449) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687173 port of SCGCQ01686105) 
 - fixed: WG: managing the manually added server fails : windows(gateway(SCGCQ01697195 port of SCGCQ01682360) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716641 port of SCGCQ01716622) 
 -(SCGCQ01718985 port of SCGCQ01698211) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01788477 port of SCGCQ01629574) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880123 port of SCGCQ01876091) 
 - handling the session management(SCGCQ01892868 port of SCGCQ01829897) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01898263 port of SCGCQ01802344) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01901754 port of SCGCQ01827404) 
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives.(SCGCQ01904075 port of SCGCQ01893304) 
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904345 port of SCGCQ01901758) 
 -(SCGCQ01920699 port of SCGCQ01808698) 
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01921839 port of SCGCQ01829669) 
 - SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS(SCGCQ01921842 port of SCGCQ01803373) 
 - WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674) 
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command(SCGCQ01930623 port of SCGCQ01926876) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01557738 port of SCGCQ01539349) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01564629 port of SCGCQ01550970) 
 - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message(SCGCQ01564682 port of SCGCQ01547992) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01569579 port of SCGCQ01514206) 
 - Support from LSA back-end to allow JBODs to be converted to UG for advance VD creation(SCGCQ01597602 port of SCGCQ01519271) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01670841 port of SCGCQ01629821) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01676281 port of SCGCQ01615856) 
 - Server schema validation is failing(SCGCQ01676389 port of SCGCQ01619401) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01679003 port of SCGCQ01563343) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01680728 port of SCGCQ01677101) 
 - LSA taking more time to discover VMWare servers(SCGCQ01681092 port of SCGCQ01681069) 
 -(SCGCQ01697478 port of SCGCQ01685009) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716625 port of SCGCQ01716622) 
 -(SCGCQ01718980 port of SCGCQ01698211) 
 -(SCGCQ01749087 port of SCGCQ01698211) 
 - Modify Properties option is enabled for VDs which are part of Transport Ready Drive Group(SCGCQ01764894 port of SCGCQ01763056) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01826237 port of SCGCQ01761830) 
 - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation(SCGCQ01837378 port of SCGCQ01833791) 
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA(SCGCQ01851919 port of SCGCQ01841280) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856730 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01891168 port of SCGCQ01889547) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD(SCGCQ01897144 port of SCGCQ01817275) 
 - Update the Windows Server 2019 OS name in LSA(SCGCQ01897178 port of SCGCQ01866322) 
 -(SCGCQ01920924 port of SCGCQ01818618) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921819 port of SCGCQ01856350) 
 - LSA 7.6 Client: Cosmetic replace drive selection issue(SCGCQ01566455 port of SCGCQ01539347) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01567176 port of SCGCQ01539326) 
 - WG: Alignment in Remote Server Discovery page changes when it is in List view and filtered with any one of the OS type.(SCGCQ01567193 port of SCGCQ01471834) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569137 port of SCGCQ01538253) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569138 port of SCGCQ01538253) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01569488 port of SCGCQ01540821) 
 - Client:Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01597592 port of SCGCQ01518206) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601608 port of SCGCQ01598515) 
 - WG: empty details for policy change displayed in events "Previous = Current Write Policy: Now = Current Write Policy:"(SCGCQ01635759 port of SCGCQ01625912) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01635779 port of SCGCQ01629821) 
 - TR VD should be excluded from the PR VD list(SCGCQ01677110 port of SCGCQ01677062) 
 - Implemented: Allow mixing of nvme drives to be mixed with SATA/SAS drives(SCGCQ01697042 port of SCGCQ01697026) 
 - Hercules : Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails(SCGCQ01789156 port of SCGCQ01731931) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01816428 port of SCGCQ01641760) 
 - Handling the set text mechanism in client(SCGCQ01886532 port of SCGCQ01850387) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01897181 port of SCGCQ01841473) 
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,(SCGCQ01915812 port of SCGCQ01906914) 
 - LSA 7.8:Import option is given for the Incomplete foreign VD(SCGCQ01921678 port of SCGCQ01865420) 
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01961510 port of SCGCQ01889547) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01697480 port of SCGCQ01681070) 
 - Add Virtual Drive option is available for DGs with Transport Ready feature set(SCGCQ01764885 port of SCGCQ01763052) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01828400 port of SCGCQ01538253) 
 - Fixed: Crash when pressing back button after logout(SCGCQ01892905 port of SCGCQ01865309) 
 - Remove un printable characters from LSA log(SCGCQ01901769 port of SCGCQ01901760) 
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) 
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives(SCGCQ01921580 port of SCGCQ01823858) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565119 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01569761 port of SCGCQ01555955) 
 - Unable to import foreign secured VDs with different security key(SCGCQ01731357 port of SCGCQ01670139) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01794950 port of SCGCQ01793057) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01817915 port of SCGCQ01793057) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01897099 port of SCGCQ01761801) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01564631 port of SCGCQ01540821) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01679329 port of SCGCQ01675460) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01698150 port of SCGCQ01590450) 
 - LSA needs proper message for max config import(SCGCQ01813925 port of SCGCQ01764977) 
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) 
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01564737 port of SCGCQ01514206) 
	
EnhancementRequests:
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399204) 
 - Part 2 of 2: Support TCG Opal 2.0 via SafeStore for VDs and SystemPD (Legacy JBOD) in RAID Mode and JBOD/SDS Modes(SCGCQ01599762) 
 -(SCGCQ01740789) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399205) 
 - Manually add server details to the list of servers(SCGCQ01539514) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01740787) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01401460) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746609) 
 - Manual discovery of servers(SCGCQ01539471) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01802344) 
 -(SCGCQ01599763) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746608) 

004.069.000.000  - Moderate Impact
--------------- 
Defects (20)
-.(SCGCQ01753405)
- Server: LSA GUI Not Updating Security Key Info.(SCGCQ01761801)
- CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275)
- Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404)
- Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01841473)
- LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856350)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209)
- fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01833469)
- LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ01838943)
- LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953)
- fixed: Info "1920 more drives can be added" need to change in LSA.(SCGCQ01827401)
- The display wrong location in page(SCGCQ01836732)
- LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01818960)
- LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives.(SCGCQ01850008)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091)
- Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01866289)
- Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305)
- Security Key Confirm Text box should not accept the copy of anything.(SCGCQ01788477 port of SCGCQ01629574)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856730 port of SCGCQ01856350)
- The LSA is failing to take into account current USED PDs from another configured VD during next VD creation.(SCGCQ01837378 port of SCGCQ01833791)
- SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in.(SCGCQ01828400 port of SCGCQ01538253)
- Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01817915 port of SCGCQ01793057)
- SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895)

EnhancementRequests (20)
- RTTrace API Changes.(SCGCQ01745568)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01802344)


004.062.000.000  - Moderate Impact
--------------
fixed:
Nginx versions since 0.5.6 up to and including 1.13.2 are vulnerable to integer overflow vulnerability in nginx range filter module resulting into leak of potentially sensitive information triggered by specially crafted request.https://nvd.nist.gov/nvd.cfm?cvename=CVE-2017-7529.

Defects (109)
- LSA server report for iMR Inv controller displays dedicatedHotSparePerDriveGroup is 0 under "maxLimit".(SCGCQ01375788)
- SCGCQ01393056: Enclosure ID is coming up as null in LSA.(SCGCQ01393056)
- WG: Error message not fitting inside the message box in "Enable Drive Security" page..(SCGCQ01442477)
- WG: Issues pertaining to 'Make JBOD Secure' Pop up.(SCGCQ01446801)
- PerfImp: Don't handle SLIM_EVT_EXCEEDS_MAX if there is no event requires complete refresh.(SCGCQ01447165)
- WG: UI Pattern in "Virtual Drive Settings" is not uniform while creating and modifying VD properties..(SCGCQ01447697)
- WG: "Change" button shown as disabled when user tries to change Behavior mode..(SCGCQ01450713)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG: success message box for "change personality" does not have proper border.(SCGCQ01453980)
- WG: Event Log table headers needs space - Cosmetic.(SCGCQ01460053)
- WG: Notification after saving the changes in "Manage Power Save Settings" needs cosmetic change..(SCGCQ01460078)
- Requested personality field is not updated for Ventura.(SCGCQ01465642)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)
- WG: Tooltip for help link in "Remote Server Discovery" page is not displayed..(SCGCQ01471842)
- WG: "Available UG drives" form is shown blank when "Type" is selected from ALL to any other drives..(SCGCQ01472186)
- WG: LSA showing inappropriate message after securing a DG using FDE security..(SCGCQ01472201)
- Buttons are inconsistent in Email Settings page of LSA.(SCGCQ01472752)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.().(SCGCQ01474461)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01482320)
- During Advanced Vd Creation PD selection order is not maintained by the client.(SCGCQ01498969)
- Display the ROC temperature in Fahrenheit as well along with Celsius.(SCGCQ01504619)
- WG: Hand mouse pointer is used in " Background Process progress " window , where it shows the name of background operations..(SCGCQ01505999)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Caps letter is expected in Settings for Alert settings successful and restore default value successful message..(SCGCQ01509253)
- WG: Sorting of drives by model number does not work for JBOD drives.(SCGCQ01511247)
- Do not allow the user to manage Personality Panel if set personalty is not supported.(SCGCQ01514527)
- SCGCQ01515443: WG: Typo in Event ID: 114 of PD state Change event related to sheild state.(SCGCQ01515443)
- 502 bad gate way observed on enclosure cable push/pull.(SCGCQ01524150)
- WG : LSA allows to add VD on offline DriveGroup and operation fails anyways.(SCGCQ01526342)
- MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01532725)
- LSA shows wrong diskgroup info when you have foreign PD.(SCGCQ01590450)
- Lenovo_18B: Not able to set max no of PD using set patrol read properties in LSA/Storcli.(SCGCQ01681070)
- Fixed: LSA handle count increase was observed.(SCGCQ01713154)
- Lenovo CIT 18B: LSA Linux doesn't have latest storelib.(SCGCQ01713580)
- SCGCQ01385340: Health is not coming proper after foreign config import..(SCGCQ01385340)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389892)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01419325)
- WG: Not all space in "Foreign Configuration" tab is clickable..(SCGCQ01467702)
- WG: Font style across the "Advanced Configuration" form should be made same..(SCGCQ01472063)
- Removing dead code from LSA7.5 stream..(SCGCQ01472185)
- WG: "Ok" button needs to be in caps in "Mixed listed drives" confirmation page and one more cosmetic change..(SCGCQ01472190)
- WG: There is no alignment for the error message while user changes the personality mode when PR is in progress..(SCGCQ01474932)
- WG: LSA is not allowing User to change No of PD's allowed for Patrol Read in Set PR properties through KeyBoard..(SCGCQ01479402)
- WG: Trying to clear configuration does not show any warning in server summary page regarding cached data, in CC page it shows.(SCGCQ01486698)
- WG: Select all check box is still selected even if one of the drive group is unselected while assigning HSP to existing DG.(SCGCQ01488141)
- WG: while creating FDE VD, type by default is selected as "All" in PD selection pane, unable to select all FDE drives.(SCGCQ01488169)
- Requested personality field is not updated for Ventura.(SCGCQ01494598)
- temperature change in controller is not refeclected in LSA..(SCGCQ01500344)
- Set patrol read window shows a time in past..(SCGCQ01503810)
-.(SCGCQ01508528)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01509259)
- WG: LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01509708)
- LSA Server: Set Patrol read is not shown when the volume is created with SSD.(SCGCQ01511260)
- SCGCQ01513209: WG: Simple configuration tab show invalid options before the raid level drop down list the supported raid levels.(SCGCQ01513209)
- WG : Advanced configuration tab gets disabled after secure erasing the FDE foreign drives.(SCGCQ01514728)
- SCGCQ01521013: MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01521013)
- MR 7.5_LSA: LSA keeps on refreshing during the background operations- Full init, RLM, CC etc.(SCGCQ01522807)
- WG: Behavior mode is missing in "personality management" window..(SCGCQ01523045)
- SCGCQ01525738: MR 7.5_LSA: Wrong nginx version is reported in linux ( SLES and RHEL ) Operating Systems..(SCGCQ01525738)
- Instance validation issues with LSA build 4.55 with IR3 controller.(SCGCQ01528425)
-.(SCGCQ01628332)
- WG: Current Profile is not selected by default in the table that lists the available profiles for the controller..(SCGCQ01442481)
- WG: "%" is accepted along with the input for Expand VD value - But not accepted for all..(SCGCQ01445384)
- WG: Partition line is required in Controller Properties Page..(SCGCQ01445396)
- WG: Status icon of physical drive is not changed after changing the state of the PD from rebuild to offline..(SCGCQ01461144)
- WG:LSA doesn't allow to secure more than one DG using FDE..(SCGCQ01472853)
- SCGCQ01474327: Handle dynamic length serial number as part of serial number VPD page 0x80.(SCGCQ01474327)
- WG: GUI : Cosmetic issues in clear configuration notificationp.(SCGCQ01486692)
- WG: LSA does not notify the user with notification on starting the VD initialization.(SCGCQ01487270)
- WG: able to add VD for scheduling consistency check even after all the VD's have been deselected.(SCGCQ01489509)
- WG:Add physical Drive button is clickable before VD list is loaded while scheduling CC or PR, no notification to user to wait.(SCGCQ01489885)
- LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01489942)
- LSA: Virtual drive, spare and drivegroup is not supported for IT but seen in URI response for Physical drives..(SCGCQ01500099)
- WG: Selection of different drive type is activated after few clicks.(SCGCQ01503786)
- RWC3 launch tab is showing the LSI Storage Authority.(SCGCQ01503896)
- WG : Pop up for securing FDE drive has inconsistency in text.(SCGCQ01507972)
- In settings window "Restore Default Alert settings" button is not saving the default values.(SCGCQ01508002)
- WG: Confirm Check box is not aligned with the "Enable Security" button.(SCGCQ01511250)
- LSA WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01511390)
- WG:Server Logs does not contain status of energy pack it mentions "Requested element not found in the stack.":error "69634".(SCGCQ01512318)
- WG: Spell Check issues with "message_en.js" used for displaying the GUI notification.(SCGCQ01512377)
- Sorting of Event logs wrt View Events and Download Logs.(SCGCQ01512750)
- WG: LSA add physical Disks pane shows empty drive list even if there are 182 drives for adding for RLM operation.(SCGCQ01513656)
- Controller operations schema instant validation is failed.(SCGCQ01514528)
- WG: LSA shows the message "The virtual disk has not been initialized" even when 32 VD's have been selecte.(SCGCQ01521694)
- Lenovo-18B: IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3.(SCGCQ01595641)
- WG: "Virtual Drive expanded successfully" message is still shown even after the page refresh post VD expansion..(SCGCQ01445693)
- WG: Cosmetic changes required in tooltip messages of Configure options in Controller Actions..(SCGCQ01447797)
- WG: Space is required between RAID and it's type in Available UG drives form and one more cosmetic change..(SCGCQ01472194)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- LSA: partial VD hide operation is failing..(SCGCQ01484118)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01506090)
- WG:Launching LSA using ip:2463 in browser, User can see the HOME page flash before redirecting to Remote discovery.(SCGCQ01439795)
- WG: LSA displays empty box instead of "Action Successful" for "Prepare for removal" and "Undo prepare for removal".(SCGCQ01447823)
- WG: "Adding the virtual drive will add the corresponding virtual drives for PR" is not shown when "select all" box is used..(SCGCQ01461133)
- WG: Size of "Back" & "Save" buttons are not same once the user saves the changes after scheduling CC.(SCGCQ01472749)
- WG: Hand symbol is not seen for close button while Adding drive during reconstruction of a DG.(SCGCQ01473748)
- Disabling the add PD button.(SCGCQ01488036)
- WG: no notification shown on assigning dedicated hotspare to existing DG.(SCGCQ01488155)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01509681)
- WG: Error message on a failed operation of RLM in displayed outside the allocated space.(SCGCQ01515263)
- WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01442471)
- WG: Expand windows is showing the capacity in decimal value with too many integers after decimal point..(SCGCQ01445686)
- Address Code review defects for ER SCGCQ01416373.(SCGCQ01455923)
- WG: Ambiguous "Success" message needs to be changed for disabling drive security.(SCGCQ01461177)
- Cannot import foreign configuration from LSA.(SCGCQ01524354)
- WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space.(SCGCQ01563343)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSABug.(SCGCQ01599526)

EnhancementRequests (20)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
-.(SCGCQ01404233)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461207)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- LSA: Make heavy operation by wrapping scheduler call.(SCGCQ01416373)
 - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443721)
- LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443731)
- Support drive Select ALL functionality in LSA GUI PD Operations and Mixing of drives during vd creation.(SCGCQ01454110)
- SCGCQ01454353: Retrieve and process the ESXi events in a single shot.(SCGCQ01454353)
-.(SCGCQ01454367)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- We will be removing the confirmation popup from all the actions as we got here from multiple forms like this pop up is annoying.(SCGCQ01447015)
- Support drive Select ALL functionality in LSA GUI VD/DG Operations.(SCGCQ01453114)
-.(SCGCQ01472631)

CSETActivities (87)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411631 port of SCGCQ01397546)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01420224 port of SCGCQ01419325)
- LSA service is not working in Linux.(SCGCQ01443712 port of SCGCQ01442733)
- WG: Event Log table headers needs space - Cosmetic..(SCGCQ01464556 port of SCGCQ01460053)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01466763 port of SCGCQ01424621)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Updated PD firmware version is not reflecting even after LSA refresh..(SCGCQ01501204 port of SCGCQ01382013)
- Cisco_Plumus_LR :Proper spacing should be there in between Event and History in view event logs "EventHistory not generated"..(SCGCQ01502201 port of SCGCQ01385344)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure.(SCGCQ01503907 port of SCGCQ01315392)
because of which the issue.(SCGCQ01503926 port of SCGCQ01288032)
- fixed: clear drive should not be candidate drive for create configuration.(SCGCQ01503958 port of SCGCQ01196088)
- Fixed: Span order is in reverse compare to other apps.(SCGCQ01504234 port of SCGCQ01330269)
- LSA shows max pd for Raid 1 without checking support of Raid 1E.(SCGCQ01514472 port of SCGCQ01513338)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531154 port of SCGCQ01521114)
- Making rebuild drive offline lsa gets 404..(SCGCQ01564627 port of SCGCQ01542412)
- LSA Crashes after clicking on foreign configuration.(SCGCQ01564739 port of SCGCQ01545262)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565025 port of SCGCQ01504080)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01565116 port of SCGCQ01555955)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621 )
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01599402 port of SCGCQ01563340)
- MR7.6_LSA: No Foriegn configuration details is shown in LSA.(SCGCQ01605344 port of SCGCQ01581943)
- fixed: logout causing unexpected behavior during end cim connection for vmware systems.(SCGCQ01609343 port of SCGCQ01578248)
- SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page..(SCGCQ01614982 port of SCGCQ01355833)
- LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group..(SCGCQ01617930 port of SCGCQ01401460)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01620406 port of SCGCQ01506090)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01634072 port of SCGCQ01473733)
- Raid 1 Volume creation using 4 drives is displayed as Raid 1E.(SCGCQ01686231 port of SCGCQ01686106)
- Cannot use Special Characters in Domain Name for LSA Login.(SCGCQ01747012 port of SCGCQ01745768)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected..(SCGCQ01448948 port of SCGCQ01442107)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01460039 port of SCGCQ01451571)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts..(SCGCQ01465657 port of SCGCQ00903348)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01466743 port of SCGCQ01451571)
- LSA server giving null for enclosure serial number.(SCGCQ01466744 port of )
- Address Code review defects for ER SCGCQ01416373.( port of SCGCQ01445713)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01484107 port of SCGCQ01482320)
- Added fwflash status as part of controller health status.(SCGCQ01503830 port of SCGCQ01375153)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure because of which the issue.(SCGCQ01503955 port of SCGCQ01288032)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01514258 port of SCGCQ01506045)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01514469 port of SCGCQ01507989)
- Allows raid 1e input even if RAID 1E is not supported by fw.(SCGCQ01514756 port of SCGCQ01513331)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01564633 port of SCGCQ01562368)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- WG: LSA service crashes on trying to login with URI having incorrect mac address of the server.(SCGCQ01615042 port of SCGCQ01601386)
- MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01685343 port of SCGCQ01641760)
-.(SCGCQ01685548 port of SCGCQ01685009)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687173 port of SCGCQ01686105)
- LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716641 port of SCGCQ01716622)
- SDS/HBA progress issues.(SCGCQ01460070 port of SCGCQ01052983)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01460084 port of SCGCQ01435908)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461211 port of SCGCQ01461207)
- C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01501225 port of SCGCQ01321211)
- Cisco - CSCve68492 - Storage Logs display a blank event when a secure PD is unlocked.(SCGCQ01503902 port of SCGCQ01359128)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01514773 port of SCGCQ01509259)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01526363 port of SCGCQ01509681)
- SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message.(SCGCQ01564682 port of SCGCQ01547992)
- LSA: Warning Message needs to be changed when there is Controller firmware update failure.(SCGCQ01604992 port of SCGCQ01564526)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSA.(SCGCQ01633836 port of SCGCQ01599526)
- Secure Jbod unlock is not showing the proper error message in LSA.(SCGCQ01680728 port of SCGCQ01677101)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687172 port of SCGCQ01686080)
- Cisco - CSCvi84075 - LSA, CTRL-R and HII doesn't display the foreign config when MAX VDs are present.(SCGCQ01718980 port of SCGCQ01698211)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460090 port of SCGCQ01460076)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460400 port of SCGCQ01448976)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01481410 port of SCGCQ01474461)
- LSA build script automation for VBAS environment.(SCGCQ01497385 port of SCGCQ01385344)
- Activity to check-in version files in common.(SCGCQ01520315 port of SCGCQ01512599)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- LSA Client 7.6: SPAN drives order is not maintained.(SCGCQ01614833 port of SCGCQ01539355)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline..(SCGCQ01443689 port of SCGCQ01442554)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux..(SCGCQ01480902 port of SCGCQ01479375)
- LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs..(SCGCQ01564943 port of SCGCQ01534444)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565119 port of SCGCQ01504080)
- Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time.(SCGCQ01676612 port of SCGCQ01670094)
- LSA Wont display foreign data when enclosure information in not populated properly.(SCGCQ01686054 port of SCGCQ01685449)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
-.(SCGCQ01564591 port of SCGCQ01515389)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01460393 port of SCGCQ01436886)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive..(SCGCQ01564629 port of SCGCQ01550970)
- LSA WG Fury IT: Controller type is showing as IR for IT card.(SCGCQ01564631 port of SCGCQ01540821)
- I/Os are not recover after drives pull for DHSP to rebuild..(SCGCQ01564737 port of SCGCQ01514206)

4.011.000.000 - Moderate Impact
-------------
Defects (234)
- SDS/HBA progress issues.(SCGCQ01052983)
- Fixed: Added relevant null pointer checks.(SCGCQ01319978)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01321474)
- Start PatrolRead success dialog box needs change in alignment.(SCGCQ01324866)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01325783)
- Link speed is not displaying any details in LSA.(SCGCQ01326129)
- Defect to check in code review defects.(SCGCQ01329391)
- Client js file changes for 7.3.(SCGCQ01331593)
- On Successful Firmware flash client displays improper Icon Message.(SCGCQ01332708)
- Control panel of LSA Help & support link still has reference to LSI. should be changed to broacom.(SCGCQ01337321)
- LSA asks for user permission to navigate away on clicking home button after creating simple configuration.(SCGCQ01338009)
- WG: GUI Issues pertaining to FW flash ER implementation SCGCQ01273627: Request to improve message displayed during FW Update.(SCGCQ01342542)
- IR Card global hot spare assignment is not refreshing the page.(SCGCQ01345357)
- Cisco_HSW_Validation_LSA: LSA accepting decimal values for "Set Adjustable Task Rate" which is saved as round value.(SCGCQ01345553)
- LSA 7.3 Client Coverity fix.(SCGCQ01347309)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01350435)
- WG:descripancies in update firmware page after selecting load bios option.(SCGCQ01350865)
- SCGCQ01350908: WG:Temperature of Unconfigured Drive is displayed as 0C under More properties.(SCGCQ01350908)
- WG:LSA displays Redhat icon in remote discovery page ,though SUSE is installed in system.(SCGCQ01351455)
- LSA taking the max VD size value when the user presses ENTER after specifying the VD size.(SCGCQ01356216)
- SCGCQ01356217: WG: LSA Service crashes on trying the PD details of the simple config created.(SCGCQ01356217)
- LSA_MR_7.3_Alpha: Save option can be grayed out or disabled after user saves the changes for schedule CC.(SCGCQ01357152)
- LSA_MR_7.3_Alpha: LSA doesn't display consistent Foreign Configuration information to the user.(SCGCQ01358048)
- WG: Incorrect notification shown after selecting 32 virtual drives.(SCGCQ01358095)
- SCGCQ01358097: LSA_MR_7.3_Alpha: Space optimization between the size value & size unit is needed in foreign configuration page.(SCGCQ01358097)
- LSA_MR_7.3_Alpha: User cannot select "Advanced Configuration" by clicking on the description below it in Server landing page.(SCGCQ01358122)
- LSA_MR_7.3_Alpha: Space Alignment for better presentation needed in Server Profile Page.(SCGCQ01358148)
- LSA_MR_7.3_Alpha: Percentage value for the Background Operations is not seen if browser is zoomed.(SCGCQ01358261)
- LSA crash when service starts with empty LSA.conf file.(SCGCQ01358264)
- SCGCQ01358892: Buttons "Try Updating Again" is not highlighted when user attempts to flash the firmware after any failure.(SCGCQ01358892)
- SCGCQ01358947: WG: Invalid text Content displayed on selecting multiple Virtual drives/Physical Drives.(SCGCQ01358947)
- WG: "Select Personality" dropdown lists the current personality first by default.(SCGCQ01359030)
- WG: Clickable "hand icon' is not displayed when we move cursor over Bus dev text of controller in Server summary page.(SCGCQ01359034)
- SCGCQ01372670: When User tries to click on Update FW Button, LSA asks for Navigation Confirmation without displaying Update FW page for IT.(SCGCQ01372670)
- "Add CacheCade-SSD VD" tab getting greyed out after deleting created vd,even if physical drive is selected under "Add SSD pd".(SCGCQ01372722)
- WG: VD creation fails when multiple VD's are created with 1MB size.(SCGCQ01373500)
- "Finish" button in Modify drive group work even if its grayed out.(SCGCQ01374945)
- WG: Issues pertaining to Controller Diagnostic logs.(SCGCQ01375839)
- WG: GUI Issues pertaining to Instant secure erase of an FDE Drive.(SCGCQ01375858)
- There is a mismatch about Backplane (Enclosure) "Product ID" and "Enclosure Model" in LSA.(SCGCQ01376005)
- Spare URI does not respond on iMR Invader.(SCGCQ01376605)
- WG: After physically removing the PD from the R10 DG, the DG Span tab does not load.(SCGCQ01376781)
- "Since Log Clear" does not create the last event "Log Clear" in Var/log/messages.(SCGCQ01376849)
- WG: LSA does not list the Drive Group Tab , on creation of 240 VD (15 DG, 16 VD in each of DG) and reinstalling the LSA.(SCGCQ01378585)
- WG: Windows Application Event viewer lists 31 events instead of 30, after installing LSA with the option "Since Last reboot".(SCGCQ01378669)
- WG: LSA does not automatically refresh on hiding an Degraded DG.(SCGCQ01378693)
- Client: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01378778)
- Client: WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01378782)
- WG: unable to start VD initialization on 32 VD's when there are 240 VD created & Foreign configuration present in system.(SCGCQ01378808)
-.(SCGCQ01378812)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01379795)
- WG:In premium features Safe ID & Serial Number needs to be highlited for better understanding.(SCGCQ01379818)
- WG: Close button can be given with a "hand" symbol in Compare and select form like all close button in other form has.(SCGCQ01380587)
- WG: Available Unconfigured drives is not formatted properly for display.(SCGCQ01380591)
- WG: Domain Authentication is shown as Default in "MAnage Server Page".(SCGCQ01380642)
- Size increment button is not working while modifying a VD that is created in MB size.(SCGCQ01380830)
- WG: "Advanced and Simple Configuration" is enabled when UG drives are "prepared for removal" and no other drives are left.(SCGCQ01380977)
- SCGCQ01383828: LSA service crashes while trying to access the IR3 controller.(SCGCQ01383828)
- WG:VD properties were not well partitioned for CacheCade - SSD config , compare to normal VD creation in HDD.(SCGCQ01384561)
- WG: Few enhancements needed in VD Expand form.(SCGCQ01389165)
- SCGCQ01389195: WG: Naming convention for VD can be made consistent for the VD's created through Advanced and Simple configuration.(SCGCQ01389195)
- Enter key is functioning as a backspace in "Set Adjustable Task Rate" - Can be disabled.(SCGCQ01389203)
- LSA mail server settings does not allow to enter name of smtp server.(SCGCQ01389204)
- WG: No. of VD's available to create is not shown properly for spanned vd's when span depth is modified.(SCGCQ01389421)
- Storcli: Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01392000)
- WG: More Actions for drive is not working after staring and stopping Clear operation under Drives tab.(SCGCQ01392056)
- WG: User has to click twice on the table header to change the sorting order for any table in LSA.(SCGCQ01393336)
- Copyright link is taking to top of the page rather taking to Broadcom website.(SCGCQ01393706)
- WG: PD state info is not updated properly in the Drives tab after PD's are converted from online to offline.(SCGCQ01393771)
- WG: "Clear" and "Rescan" buttons could be highlighted for the better look in Foreign Configuration Tab.(SCGCQ01394954)
- "Add Virtual Drives" is grayed out for specific VD sizes after user presses "tab-alt" keys.(SCGCQ01398966)
- WG: Verify and Sign In Buttons are overlapping in list view in Manage Server Page.(SCGCQ01399610)
- LSA is not showing "Activate..." button for Premium Features when it is navigated after "Update Firmware" page.(SCGCQ01399670)
- WG:LSA sending email alert notifications to user which doesn't exist.(SCGCQ01418580)
- Drives under both Physical drives and Span drives tab are allowed to select simultaneously.(SCGCQ01428129)
- Login to VMware is taking at time more than 30 seconds.(SCGCQ01429431)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01435908)
- WG:while editing a created VD, user cannot increase the VD size in MB .Only can decrease the size.(SCGCQ01438268)
- WG:LSA is not sorting properly the drives with different capacity of units i.e TB and GB.(SCGCQ01439751)
- WG: View server profile does not contain info on the Device id, which is sorted according to device id itself.(SCGCQ01440773)
- WG: operation of Combining JBOD drives with & without files system to move to Unconfigurued good is partially successful.(SCGCQ01440778)
- WG: Space required between two strings in the description of "Enable Drive Security".(SCGCQ01442479)
- WG: LSA Displays "Error Code:1:An user is already Logged in with Different Credentials" even user is using same credentials.(SCGCQ01442773)
- WG: LSA is changing to latest login user account though it is already logged with different User Account in different Tab.(SCGCQ01442774)
- WG: No. of UG drives are improperly updated in the Drives header tab when replace operation is triggered on a physical drive.(SCGCQ01444724)
- WG: No. Of Power Supplies info displayed is overlapping on the enclosure details. Need proper display alignment.(SCGCQ01444794)
- LSA showing 'binaryPath:./LSA' during service start in Linux.(SCGCQ01445709)
- LSA server giving null for enclosure serial number.(SCGCQ01445713)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01445719)
- WG: Description for event Code"579" is '0" in LSA event logs.(SCGCQ01446803)
- WG:"Disable Data Protection" is not updating in LSA until user do a manual refresh.(SCGCQ01447843)
- SCGCQ01448707: WG: LSA Event logs has enquiry info for Vendor, model and serial numbers appended with $ symbols.(SCGCQ01448707)
- WG: Inconsistency seen w.r.t making drive online while RLM is in progress.(SCGCQ01449722)
- WG: Event log page is navigating to change personality when the behavior mode is set from other tab of the same browser.(SCGCQ01450719)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG:Controller health status not updated on moving JBOD drive from offline --> online, personality : JBOD.()
- LSA Server: Handling of additional events in Cache module.(SCGCQ01451573)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01464514)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Enclosure ID is shown "Unknown" for NVMe JBOD only in event logs, Profile id=11.(SCGCQ01291162)
- WG: LSA page does not refresh on starting Full initialization on 240 VD.(SCGCQ01292183)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- 7.3 Client : Coverity defects check-in.(SCGCQ01308624)
- SCGCQ01309034: Coverity defect fixes check-in.(SCGCQ01309034)
- Fixed: Code maintainability issue.(SCGCQ01318344)
- coverity defect fies for : Suspicious use of non-short-circuit boolean operaton.(SCGCQ01320079)
- In Simple Config, if user select a VD and select the check box of "Assign HSP", VD size is getting changed to different size.(SCGCQ01321225)
- WG: LSA notifies user that VD will be deleted after VD erase even if the option was not selected.(SCGCQ01325795)
- WG: user notification appearing after user starts/stops the initialization on multiple VD's needs to be updated.(SCGCQ01326134)
- LSA doesn't show FW component name while FW flash operation.(SCGCQ01337028)
- WG: Multiple options of RLM are selected together for radio button used to select one of the 3 RLM operations.(SCGCQ01342615)
- LSA does not display "Link Speed" for phy 8 properly for iMR Ventura.(SCGCQ01355929)
- When the CC is scheduled as "Continuously", it is not reflected in UI after saving the changes.(SCGCQ01357007)
- Warning message has to be corrected in Foreign configuration page and one more hyperlink issue.(SCGCQ01358066)
- LSA is not taking "dot(.)" from num pad , but taking "dot(.)" form keypad while specifying the vd capacity.(SCGCQ01358908)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01364736)
- WG: LSA displays the notification "This operation can be performed only on 32 drives at a time" 32 times.(SCGCQ01373067)
- WG: Global hotspare & Dedicated hotspare are displayed as plural entities for every hotspare listed in physical drive tab.(SCGCQ01375707)
- WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01375778)
- fixed: Min & Max of "PdRaidLevel_1E" under the "pdsForRaidLevels" is populated even though it is not supported in iMR.(SCGCQ01375817)
- WG: Other hardware tab lists wrong count of list of hardware connected when enclosure connected in multipath.(SCGCQ01376109)
- WG: View server profile contents exceed the border limits of the LSA page.(SCGCQ01378556)
- SCGCQ01378774: WG: Information of the virtual drive info and PD's involved in DG vanishes on removing & inserting the PD back from a DG.(SCGCQ01378774)
- WG: Links present in Backplane properties are so light that they look like grayed out. Needs enhancement.(SCGCQ01380680)
- WG: User is allowed to click on "Next" button even if page is not completely updated during the VD creation & RLM operations.(SCGCQ01381734)
- GUI Issues found in Advanced Configuration page.(SCGCQ01381764)
- Firmware flash message should have "new" removed from string.(SCGCQ01382062)
- LSA getting logged in , even if the password is wrong.(SCGCQ01388957)
- "%" is allowed for entering no. of seconds for locating the drives.(SCGCQ01389182)
- WG: Size limit warning is thrown if the user is giving valid size using spinner button while modifying VD.(SCGCQ01389340)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01389483)
- Spinner Button for increase and decrease size is not working when the size is 1.09 TB.(SCGCQ01392053)
- WG: "Username" has to be grayed out when user start typing in the login page of "Manage Server Page".(SCGCQ01393764)
- WG: UG Drives count is not updated properly after modifying a DG.(SCGCQ01393774)
- Phase 5 IT LSA - EFI-BSD version is not displayed fully when Version length is more than 12 characters.(SCGCQ01394914)
- Mismatch in enclosure properties between LSA and storecli utility.(SCGCQ01395021)
- WG: "Managing SAS Storage Link Speed" opens up on clicking help topic of "Manage PCIe Storage Interface".(SCGCQ01395075)
- when clicking on more actions for any UG drives to make DHS,the options remains as it is in LSA though the operation is done.(SCGCQ01403884)
- WG: Like "Flash Firmware" button in "Update Firmware" page, "Update" button should also have hand symbol & one more issue.(SCGCQ01405822)
- WG: while expanding exiting VD, the expand VD page is not consistent.(SCGCQ01416379)
- Fixed: WG: LSA conf does not contain the perf mode settings options configurable.(SCGCQ01422214)
- WG: Clicking on "Benefits of each MegaRAID Advanced Software Option" in premium feature is not taking to proper link.(SCGCQ01428156)
-.(SCGCQ01428383)
- LSA doesn't allow creating spanned Raid levels with 2 spans using more than 32 drives.(SCGCQ01435647)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01436886)
- WG : "Replace Drive "window needs improvement to look uniform.(SCGCQ01439805)
- when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01440772)
- WG: LSA displays the property Drive Security Capable as 'No' even when security is supported.(SCGCQ01442209)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01443879)
- WG: Confirmation Message has to be changed when more than one drives are converted from JBOD to UG state.(SCGCQ01444672)
- SCGCQ01445818: MR 7.4_Alpha_LSA does not find a server in RHEL 7.4.(SCGCQ01445818)
- WG: LSA times out after "Clear Configuration" command is issued when there is a OFFLINE DG present.(SCGCQ01447788)
- WG: Size for the VD is not updated properly when edited during VD creation.(SCGCQ01447791)
- WG: An extra "." needs to be removed in the event description for "Initialization complete on VD".(SCGCQ01449783)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- WG: Raid 50 Vd Creation fails on unselecting drives after changing span during VD creation.(SCGCQ01309542)
- Coverity Defects - Performance Inefficiencies.(SCGCQ01313878)
- Fixed: Coverity: Class hierarchy inconsistencies.(SCGCQ01318333)
- Client: Coverty defect fixes check-in.(SCGCQ01318336)
- VD size getting increased while creating VD using simple config - Regression.(SCGCQ01341947)
- WG: Once the FW update is completed LSA shows junk character in the notification about firmware flash was successful.(SCGCQ01342536)
- SCGCQ01348082: LSA: Loopback occurs during launch. (intermittent issue).(SCGCQ01348082)
- Expand page is not closed when opened for second time.(SCGCQ01357224)
- "Add Virtual Drives" is disabled when user changes from invalid size to valid size through increment button.(SCGCQ01358299)
- WG: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01375255)
- "Server Profile" displays blank back plane info for ctrl-1.(SCGCQ01375992)
- LSA Client : Foreign Configuration Panel issues with locked and unlocked foreign drives.(SCGCQ01378050)
- DG Actions menu is not shown properly after zooming in when VD's are hidden.(SCGCQ01380663)
- WG: Size range warning is not shown while modifying VD when unit is selected from MB to GB.(SCGCQ01380818)
- LSA Evevnt: Access policy for HIDDEN/Transport is coming as Empty.(SCGCQ01380828)
- LSA Server: User is provided with Hide and Un-Hide option though there is no HIDE performed on a VD.(SCGCQ01380845)
- WG: LSA service crashes on hiding and unhiding DG's with dedicated hotspare.(SCGCQ01380912)
- SCGCQ01383765: Resolve linux server compilation issues.(SCGCQ01383765)
- WG: Reconstruction progress is not refreshed even after the VD is cleared on which reconstruction was happening.(SCGCQ01383800)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01389392)
- WG: Clicking on View server profile just before controller console page loads results in blank page.(SCGCQ01396731)
- WG: "DG degraded notification" is not auto-refreshed after Raid5 VD is brought from offline to online.(SCGCQ01398964)
- WG: When LSA is configured with NAT server, it is shown twice in the Remote Discovery Page.(SCGCQ01401484)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01401546)
- WG: Hidden links present in premium features page.(SCGCQ01412883)
- WG:VD properties details need some changes to look uniform across the application.(SCGCQ01418574)
- WG: Help link for Premium Features is opening in dual tabs.(SCGCQ01428169)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected.(SCGCQ01442107)
- WG:LSA is not showing the options "Pause Patrol Read|Abort Patrol Read" when PR background operation is running.(SCGCQ01442350)
- WG:when user is closing the message box for "Clear Configuration",the "X" symbol is not shown with hand symbol.(SCGCQ01442356)
- LSA service is not working in Linux.(SCGCQ01442733)
- WG: Invalid text"Each_Frehole" present in Pop up of Adding VD to existing Drive group.(SCGCQ01446454)
- WG: "Add Hot Spare" Button is enabled after selecting and deselecting the drives.(SCGCQ01448882)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01448976)
- WG: Event with ID 552 is not updated properly. Information on Mode is empty.(SCGCQ01450725)
- LSA Client: SDS/HBA progress issue.(SCGCQ01459948)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- LSA not giving the Un Hide All Virtual Drives operation when DG contain Hidden and normal VDs.(SCGCQ01308440)
- Coverity Defects fixes for Stream LSA7.3.(SCGCQ01311864)
- LSA7.3: Coverity defect fixes in Server code.(SCGCQ01316168)
- Coverity: Integer handling issues.(SCGCQ01318418)
- LSA Client : IR/IT Multiple Options are allowed in Update Firmware Screen.(SCGCQ01343645)
- Add hot spare page cosmetic issues.(SCGCQ01358219)
- WG:Change button is active even if button appears inactive for "Change personality", fails with an inappropriate notification.(SCGCQ01358967)
- FW last modified time is not coming properly while FW upload.(SCGCQ01359056)
- WG:while editing created vd for CacheCade - SSD Caching Configuration,the write policy tab is coming down.(SCGCQ01380641)
- WG: In "Advanced Configuration" page, Raid settings and Drive Attributes are not numbered properly.(SCGCQ01380646)
- WG: Issues pertaining to "Server is taking long to respond" LSA page.(SCGCQ01383122)
- SCGCQ01395189: WG: "Manage PCIe Storage Interface" displays empty table for MR Ventura controller with profile id 13.(SCGCQ01395189)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01415223)
- WG: Question mark missing in "Erase" confirmation form.(SCGCQ01415923)
- WG: Extra "." (dot) has to be removed in VD Initialization confirmation message and one more cosmetic issue.(SCGCQ01428137)
- WG: Instance Validation is failing for driveGroupConfigurationService-schema.json in MR_Ventura card.(SCGCQ01443739)
- MR7.4_Alpha_LSA crashed when trying to download firmware RHEL 7.4.(SCGCQ01447240)
- LSA Client Refresh issue while making more than one drive(s) offline when RLM is in progress.(SCGCQ01449870)
- WG: No success /failure Notification is shown in server summary page on making a offline drive online.(SCGCQ01451575)
- WG:2 Spans(Modify Span Depth) is showing in "Advance configuraton" page even if their is no PD left for the config.(SCGCQ01452129)
- WG:when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01464425)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01479375)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ00903348)
- LSA should not allow to select the check box of VD and PD simultaneously on xSDS-None mode.(SCGCQ01323724)
- Issue : Instant Secure erase option is seen when FDE and NON-FDE drives are selected.(SCGCQ01326164)
- SCGCQ01332799: Resolve LSA server compilation issue.(SCGCQ01332799)
- LSA conf file not being updated While changing the default port 2463 and 9000 to some other free ports in windows_8.1_x64.(SCGCQ01375895)
- WG: "?" symbol is in the centre of the Drive erase page unlike in other pages.(SCGCQ01383763)
- WG: ESXi server name is not completely visible in Manage Servers page.(SCGCQ01389332)
- WG: UI Enhancement: Hand symbol has to be given for the "Modify VD" icon for better user experience.(SCGCQ01389343)
- Foreign Configuration issues locked and unlocked foreign drives count.(SCGCQ01391010)
- Action successful message needs to be modified for better User experience.(SCGCQ01392057)
- spandepth need one space between span & depth, to look uniform across the application.(SCGCQ01413225)
- Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01423352)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01460076)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01394281)
- WG: Help link for "Activate Features" after providing the Activation key is not working.(SCGCQ01398969)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01424621)
- Added the "?" at the end of instant secure erase. But there no issue related line in more actions panel please find the attached screenshot.(SCGCQ01442352)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01474461)
- 'X' symbol for removing physical drives are not highlighted when the drives are allowed to be removed.(SCGCQ01350436)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)

EnhancementRequests:
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- SLIR3: Change build scripts and makefiles to account for change in directory structure and new name of the library.(SCGCQ00293713)
-.(SCGCQ01389581)
- LSA Page tab name should be changed.(SCGCQ01401514)
-.(SCGCQ01416369)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444590)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- SLIR3: Remove Libsysfs dependency in StoreLibIR3.(SCGCQ00293709)
- Adding Solaris and Sparc X64 bit support in SLIR3.(SCGCQ00922699)
- Change library name to SLIT.(SCGCQ00933175)
-.(SCGCQ01309820)
- LSA Server : [Lenovo Purley] Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01352474)
- HBA nvdata version in Decimal Format in LSA.(SCGCQ01365643)
- WG: Dedicated Hot spare Notification pop-up alignments.(SCGCQ01401505)
- Schedule API changes for time consuming APIs.(SCGCQ01422386)
- MR7.4: Support for FW ER:SCGCQ01389581 in LSA Server.(SCGCQ01428115)
- Update the WebServer Nginx to fix the latest Security Vulnerabilities.(SCGCQ01452493)
- SAS3 Ph8 --- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00729472)
- LSA Client: Handle Progress events without initiating individual API calls.(SCGCQ01416371)
- LSA: Make operation call with query parameter.(SCGCQ01424479)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- WG: Landing page - Graphics improvements.(SCGCQ01401517)
-.(SCGCQ01412749)
- Support for FW ER:SCGCQ01389581 in LSA Client.(SCGCQ01428113)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- LSA7.3: LSA to hide the Empty back plane based on the property field in the LSA.conf file.(SCGCQ01312022)
- LSA: Make operation call with query parameter.(SCGCQ01416374)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- SCGCQ01250909 - [Lenovo Purley] - Retrieve Boot Events and Maintain it as part of Event History.(SCGCQ01291488)
- Client: EPMR12 porting to MR7.3.(SCGCQ01304973)
- Client: Provide pending profile details in LSA.(SCGCQ01331947)
- LSA Server: EPMR12 defect/feature porting to MR7.3.(SCGCQ01307382)
-.(SCGCQ01356193)
-.(SCGCQ01375857)
- WG: In Remote discovery page Self server is always listed in the last.(SCGCQ01378666)
-.(SCGCQ01472631)

CSETActivities:
- VMware LSI Out of Box driver feature reconciliation.(SCGCQ00696009 port of SCGCQ00652798)
- Provide a StoreLibIR2 deb package to work on Ubuntu.(SCGCQ00795333 port of SCGCQ00630108)
- WG: No Units are displayed for Event ID: 545: Information about super cap health.(SCGCQ01297685 port of SCGCQ01291338)
- LSA throws inappropriate error while attempt to start controller firmware upgrade when pinned cache present on controller.(SCGCQ01297819 port of SCGCQ01288364)
- CSCvd88927 - LSA is displaying drives' type string inconsistently for HDD/SSD so it needs to display consistently.(SCGCQ01331599 port of SCGCQ01316465)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336569 port of SCGCQ01313804)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337104 port of SCGCQ01332737)
- Hercules LSA : Schedule CC button does not allow to click on the whole button.(SCGCQ01339214 port of SCGCQ01337027 )
- PR on all drives are not aborted properly until page refresh is done.(SCGCQ01342568 port of SCGCQ01340808)
- No. of steps shown in "Modify Drive Group" page is not correct.(SCGCQ01343651 port of SCGCQ01341921)
-.(SCGCQ01345364 port of SCGCQ01342479)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01345398 port of SCGCQ01332912)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347171 port of SCGCQ01346904)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347220 port of SCGCQ01346908)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347221 port of SCGCQ01346908)
- Cisco_HSW_Validation_LSA: "Simple Configuration" page that appears after creating a simple config is blank.(SCGCQ01347224 port of SCGCQ01345554)
- Cisco_HSW_Validation_LSA: Character limit warning for VD name is not shown while modifying the VD during VD creation.(SCGCQ01347232 port of SCGCQ01345557)
- Cisco_HSW_Validation_LSA: VD Size limit check is not working when user modifies the value of the size.(SCGCQ01350834 port of SCGCQ01346906)
- Cisco_HSW_Validation_LSA: Prepare for removal menu is still displayed even after the option is selected and event is updated.(SCGCQ01350837 port of SCGCQ01338290)
- "%" symbol followed by integer value should not be allowed for the user to enter the size during VD creation.(SCGCQ01350844 port of CGCQ01349556)
- Page scroll doesn't work after VD creation when BG processes on VD are expanded in LSA page.(SCGCQ01351383 port of SCGCQ01349487)
- VD creation fails when a partial VD is added with decimal value & with 1MB strip size to an existing DG.(SCGCQ01354306 port of SCGCQ01348005)
- Security Key provided for importing Foreign Config is not taken by LSA.(SCGCQ01369266 port of SCGCQ01331016)
- Unexpected sense PD messages are flooded in storage log when drive is in spun dwon mode.(SCGCQ01369267 port of SCGCQ01264499)
-.(SCGCQ01375259 port of SCGCQ01373451)
- LSA: Client should not show Unlock drive option if no drives are in locked state.(SCGCQ01378557 port of SCGCQ01331121)
- LSA Server: Windows Make file check-in.(SCGCQ01384621 port of SCGCQ01384618)
- RWC3 Package: Check-in of SL-IT to the package folder.(SCGCQ01384895 port of SCGCQ01384890)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01387017 port of SCGCQ01350435)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389917 port of SCGCQ01389892)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01389918 port of SCGCQ01385340)
- HPE: Un-installation is not removing the folder(s) after performing the Download Diagnostics operation.(SCGCQ01389925 port of SCGCQ01385453)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01391318 port of SCGCQ01389483)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01419753 port of SCGCQ01417215)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ01440910 port of SCGCQ00903348)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275670 port of SCGCQ01275496)
- For phys-schema.json fails for "([0, u'properties', u'isEnabled', u'enum'], 'False ...".(SCGCQ01309844 port of SCGCQ01304900)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01323613 port of SCGCQ01284395)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324865 port of SCGCQ01260226)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01338337 port of SCGCQ01331755)
- Hercules LSA : Cachecade SSD caching should be "enabled" under controller properties.(SCGCQ01339133 port of SCGCQ01337029)
- Hercules LSA : WB and AWB description in LD create page not proper.(SCGCQ01339213 port of SCGCQ01337026)
- User couldn't enter his value in seconds for locating a physical drive.(SCGCQ01344082 port of SCGCQ01332742)
- Cisco_HSW_Validation_LSA: Tooltip for "Simple Configuration" is not shown when other options displays it.(SCGCQ01347225 port of SCGCQ01346851)
- Cisco_LSA: Hyperlink symbol can be shown for "Compare and select" link in Modify Drive Group.(SCGCQ01350847 port of SCGCQ01348107)
- Cisco_HSW_Validation_LSA: Naming convention can be made same across all "Virtual Drive Erase" forms.(SCGCQ01350850 port of SCGCQ01347250)
- cosmetic changes required in "Advanced configuration" page.(SCGCQ01350851 port of SCGCQ01347253)
- DG health is not populated properly in cisco cards.(SCGCQ01350892 port of SCGCQ01349625)
- Virtual Drive Erase form is not closed when it is opened for the second time.(SCGCQ01351381 port of SCGCQ01347243)
- While adding drives to any raid group, Displaying no. of available drives and selected drives can be fine tuned.(SCGCQ01351385 port of SCGCQ01348115)
- Cisco_LSA: "Background Initialization" is misspelled in Event description & one more cosmetic change is required.(SCGCQ01351454 port of SCGCQ01348041)
- In case of FW upload, LSA crash seen with big FW version name.(SCGCQ01351457 port of SCGCQ01338340)
- LSA Client: During the exclusion of the VDs from deletion of one VD leading to the deletion of all the VDs.(SCGCQ01354432 port of SCGCQ01344115)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01387009 port of SCGCQ01379795)
- Hercules:LSA:Observe that instead of "Feedback " it is named as "FeedBack ".(SCGCQ01389091 port of SCGCQ01388943)
- Updated PD firmware version is not reflecting even after LSA refresh.(SCGCQ01392422 port of SCGCQ01382013)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01393239 port of SCGCQ01385340)
- Hercules LSA: "Prepare for removal" feature should be disabled for drives in LSA.(SCGCQ01401490 port of SCGCQ01396735)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- Updating readme file.(SCGCQ01294583 port of SCGCQ01294570)
- For spares-schema instance validation failed for "u'foreign' is not one of [u'NATIVE', u'FOREIGN', u'MIXED']".(SCGCQ01311504 port of SCGCQ01309617)
- LSA server:LSA not showing the server reboot message after profile set.(SCGCQ01316473 port of SCGCQ01316342)
- HSW_testing_LSA : Could not initialize a VD after disabling and enabling again "Initialize" option.(SCGCQ01321339 port of SCGCQ01309783)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337071 port of SCGCQ01332737)
- Cisco_HSW_Validation_LSA: Size range warning is not shown when user is giving value beyond the limit in MB unit.(SCGCQ01352603 port of SCGCQ01352603)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01369283 port of SCGCQ01284395)
- RWC3 Automation Script files check-in.(SCGCQ01385008 port of SCGCQ01384997)
- LSA/RWC Automation batch files check-in.(SCGCQ01386218 port of SCGCQ01386214)
- Hercules:LSA: trying to open in new tab : "Copyright @ 2017 by Avago Technologies. All Rights Reserved" loads blank page.(SCGCQ01389089 port of SCGCQ01386140)
- Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01389588 port of SCGCQ01352480)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01392429 port of SCGCQ01385340)
-.(SCGCQ01392506 port of SCGCQ01391775)
- [Lenovo 17B] - LSA- Selected Firmware version doesn't match while upgrading the FW.(SCGCQ01420040 port of SCGCQ01417199)
- Hercules:LSA: Multiple OLH links are opening when clicked on Advance configuration( IE Browser).(SCGCQ01429992 port of SCGCQ01415979)
- LSA Linux BST Automation scripts.(SCGCQ01466009 port of SCGCQ01447013)
- operations-schema.json fails for "u'percentage' is a required property..." in xSDS mode.(SCGCQ01297806 port of SCGCQ01291332)
- Hercules LSA : Auto refresh not happening on Enclosure push pull with 64 VD's configured.(SCGCQ01297821 port of SCGCQ01276760)
- SCGCQ01309545: WG: Issues pertaining to Event ID: 545: Super Cap Health event has redundant data, missing comma's.(SCGCQ01332698 port of SCGCQ01309545)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01338335 port of SCGCQ01332912)
- Cisco Validation: FW throws an exception while scheduling Consistency check on R1.(SCGCQ01347254 port of SCGCQ01340788)
- VD size is created with improper size when user creates volume by first decreasing and increasing the size in MB unit.(SCGCQ01350833 port of SCGCQ01346860)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01395078 port of SCGCQ01394281)
- Wrong API populated for enclosures operations and schema will fail.(SCGCQ01445408 port of SCGCQ01444689)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01447743 port of SCGCQ01445719)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01458204 port of SCGCQ01443879)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336556 port of SCGCQ01313804)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347125 port of SCGCQ01346904)
- Cisco_HSW_Validation_LSA: Credentials asked during login is not proper when login mode is set to 'Domain Login'.(SCGCQ01347233 port of SCGCQ01341930)
- Hercules-LSA : Updated PD firmware version is not reflecting automatically.(SCGCQ01393283 port of SCGCQ01392496)
- Hercules:LSA: Linux RHEL 6.9: View Event Logs Icon display not proper.(SCGCQ01414738 port of SCGCQ01409445)
- Hercules LSA: Reference to "drive group" while adding logical drive to existing array.(SCGCQ01444720 port of SCGCQ01444670)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01480902 port of SCGCQ01313228)
- Fixed: Drive group Migration was disabled with NVME drives DG.(SCGCQ01313228 port of SCGCQ01289586)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324864 port of SCGCQ01260226)
- Spare URI does not respond on iMR Invader.(SCGCQ01378677 port of SCGCQ01376605)
- [PA_2017B_SDV_Lenovo_x3650 M4_Storage] LSA tool update FW Image (oss: 75871) Failed for N2225 SAS HBA(Outback-2) card.(SCGCQ01408778 port of SCGCQ01408626)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411632 port of SCGCQ01397546)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01417213 port of SCGCQ01415347)
-.(SCGCQ01417223 port of SCGCQ01375862)
- LSA: Make operation call with query parameter.(SCGCQ01423429 port of SCGCQ01416374)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01427110 port of SCGCQ01419325)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01345397 port of SCGCQ01331755)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01354345 port of SCGCQ01321474)
- Hercules LSA: Default write policy for R1 CC VD should be WB instead of WT.(SCGCQ01401352 port of SCGCQ01397557)
- [Lenovo 18A] 110340 - [PA_2017B_SDV_Lenovo_Red_Reno_Storage] Use LSA to configure M5225 and it fail to create VD's from LSA.(SCGCQ01424599 port of SCGCQ01421451)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline.(SCGCQ01443687 port of SCGCQ01442554)
- Phase 2 changes for Linux VBAS automation script.(SCGCQ01460081 port of SCGCQ01455968)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
- CSCvd28635: LSA throws inappropriate error while attempt to start patrol read on virtual drive with SSDs.(SCGCQ01319398 port of SCGCQ01284997)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01332824 port of SCGCQ01325783)
- To resolve the merge conflict.(SCGCQ01348161 port of SCGCQ01348057)
- Port Info disappears on doing Drive push pull.(SCGCQ01404636 port of SCGCQ01379323)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444595 port of SCGCQ01444590)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)


3.023.000.000 - Moderate Impact
-------------


2.090.000.000 - Moderate Impact
-------------
Enhancement:
- Added Support for ThinkSystem HBA and RAID adapters


2.085.000.000 - Moderate Impact
-------------
- Fixed issue where logs incorrect when remove/insert hdd (SCGCQ01246085)
- Fixed Invalid Server Id as part of event, if server is not in network (SCGCQ01261779)
- Fixed issue where moving PD from slot 0 to another slot, PD slot ID usually still show slot 0 and slot format (SCGCQ01264554)
- Fixed issue where external enclosure serial number in not consistent between LSA, MSM and storcli (SCGCQ01268914)
- Fixed issue where LSA does not list Raid 10 as configurable raid level under configuration service uri when drive mixing is allowed (SCGCQ01037806)
- Fixed issue where Incorrect configurable Volume sizes displayed in LSA for Raid 0(SCGCQ01039518)
- Fixed issue where LSA is not un-installing through the Uninstall-LSA option through Windows All Programs (SCGCQ01039698)
- Fixed issue where VD Properties in LSA was not getting populated for default settings (SCGCQ01043610)
- Fixed issue where controllers/{id}/spares is not populated correctly (SCGCQ01056900)
- Fixed issue where LSA displays only 2 enclosures when four enclosures are connected. (SCGCQ01061548)
- Fixed issue where Enclosure more properties displays "Number of Voltage Sensors" as "0" (SCGCQ01063504)
- Fixed issue where On Number of Temperature Sensors observe that temperature mentioned has 65535 C. (SCGCQ01063924)
- Fixed issue where When the PD is in GHS state LSA is displaying the Prepare for removal option (SCGCQ01064282)
- Fixed issue where LSA does not display the access policy 'hidden' in View Event Logs. (SCGCQ01065622)
- Fixed issue where schedule patrol -read throws an error 'Invalid URI parameter' when user clicks on Finish button. (SCGCQ01066126)
- Fixed issue where Unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01066154)
- Fixed issue where LSA crashes while trying to add a VD to the RAID 00 drive group. (SCGCQ01069405)
- Fixed issue where Simple configuration fails while trying to create VD using SSD Drive (SCGCQ01069412)
- Fixed issue where compared with MSM values of "Date of manufacture" and "Type" is varying. (SCGCQ01069493)
- Fixed issue where Unable to clear or import partial foreign configuration from LSA. (SCGCQ01069580)
- Fixed issue where Ventura: LSA still displays clear button as active even after successfully importing foreign configuration. (SCGCQ01069616)
- Fixed issue where IR3 Events logs are listed reverse sequence in "View Event logs" (SCGCQ01069847)
- Fixed issue where LSA Drive Tab PD "Unconfigured Good" count does not automatically refresh when we Move UG PD to JBOD and vice versa(SCGCQ01069852)
- Fixed issue where Modifying the VD during the VD creation results in option for user to allow more than one cachecade VD, Creation fails (SCGCQ01069898)
- Fixed issue where Instance validation fails for Clear Drive, Stop Clear Drive, Prepare & Undo prepare for removal due to "parameters":{}" (SCGCQ01070441)
- Fixed issue where Instance validation fails for Manage Power Save Settings, Controller PUT operation (SCGCQ01070690)
- Fixed issue where Instance Validation fails for Schedule Consistency Check (SCGCQ01070739)
- Fixed issue where Instance Validation fails for Physical Devices GET (IT controller) (SCGCQ01074960)
- Fixed issue where Server not found warning message is displaying repeatedly one over the other (SCGCQ01075026)
- Fixed issue where Backplane information not displayed under view server profile (SCGCQ01075841)
- Fixed issue where if config cleared during reconfiguration, progress bar does not clear(SCGCQ01075843)
- Fixed issue where hide on DG is not automatically updating the access policy of VDs (SCGCQ01076009)
- Fixed issue where LSA Crashes when we run API performance Script ususally when performing PD Operations GET in Large config (240 PD)(SCGCQ01076023)
- Fixed issue where "Controller Info" of LSA displays driver version of the Gateway server instead of displaying the driver of Vmware server (SCGCQ01076031)
- Fixed issue where "Application Version" in server profile page is displayed as "LSA Server null". (SCGCQ01076146)
- Fixed issue where there were multiple extra columns in PD tab (SCGCQ01077452)
- Fixed issue where the Physical devices are listed in Decreasing order of Device ID instead of ascending order in drive tab (SCGCQ01077563)
- Fixed issue where firmware update does not happen in the Direct agent system from Gateway (SCGCQ01077677)
- Fixed issue where Manage Power save settings with input of " 1 hour" fails with an error " Input Parameters are Invalid" (SCGCQ01078509)
- Fixed issue where Managed Server page provides option of adding gateway server from which we have already logged in to manage server (SCGCQ01078524)
- Fixed issue where Feedback is displayed as FeedBack in LSA. (SCGCQ01079092)
- Fixed issue where After adding server in Manage Server Page intermittently get a junk screen  (SCGCQ01079698)
- Fixed issue where back button does not work in case of Advanced Configuration During VD Creation (SCGCQ01079912)
- Fixed issues pertaining to "Set Patrol Read Properties" Number of PD Count allowed for patrol read (SCGCQ01080265)
- Fixed issue where after logging out from server that is been managed. Clicking Server again in managed server page LSA asks for credentials (SCGCQ01080448)
- Fixed issue where Instance Validation fails for PROGRESS related Operations (SCGCQ01082194)
- Fixed issue where Instance validation fails for "/controllers/0/operations/security" URI : Controller Operation POST (SCGCQ01082618)
- Fixed issue where inappropriate error message is displayed in LSA on flashing fw on IT Intruder (SCGCQ01082897)
- Fixed issue where LSA page does not automatically refresh when PD moved from UG bad to UG Good SS page, CC page does not give option (SCGCQ01083060)
- Fixed issue where on clicking save button on mail server page its shift to Alert Settings without saving that page. (SCGCQ01083063)
- Fixed issue where LSA does not show the default power save mode time set in mfc (SCGCQ01083106)
- Fixed issue where after adding server the managed server list, then logging out, new server cannot be logged into. (SCGCQ01083226)
- Fixed issue where LSA service is not present in the Windows services after downgrading LSA. (SCGCQ01084774)
- Fixed issue where Event Response is giving Default Write Policy: abc (SCGCQ01043609)
- Fixed issue where Sending Invalid HTTP verb in the request for an URI fails with 404 instead of 405 (SCGCQ01059216)
- Fixed issue where texts linked to the health icons "optimal", "critical", "needs attention", in server summary page Should be clickable (SCGCQ01063432)
- Fixed issue where LSA still displays physical disk actions and properties menu when no pd is selected after sorting from Enclosure/slot. (SCGCQ01063524)
- Fixed issue where Instance Validation fails for Simple Configuration POST (SCGCQ01064737)
- Fixed issue where consistency check Schedule parameters is available even after selecting the "Disable" from the Consistency check mode (SCGCQ01069825)
- Fixed issue where LSA not accessible through Chrome browser Version 48.0.2564.109 m (SCGCQ01078618)
- Fixed issue where while initiate ISE against 3rd party locked UG drive, XHR_Header code says "POST 200" but XHR_Response says "Er 77" (SCGCQ01080402)
- Fixed inconsistency between the VD properties displayed in STORCLI when compared with other Apps. (SCGCQ01081145)
- Fixed issue where LSA doesn't get updated without a service restart on Vmware server with IR3 controller. (SCGCQ01081324)
- Fixed issue where matching error description is not shown by client when there is a session already active during login. (SCGCQ01063542)
- Fixed issue where LSA login attempt failed for Vmware Server (SCGCQ01064784)
- Fixed issue where 002.010.000.000 build (Gateway & Standalone) is unable to discover server (SCGCQ01069396)
- Fixed issue where replace drive table does not have device Id column (SCGCQ01075112)
- Fixed issue where LSA does not update the data automatically when Delete VD is performed. (SCGCQ01079635)
- Fixed issue where RWC3-LWM (Windows) is unable to send mail to SMTP (SCGCQ01173361)
- Fixed issue where Ventura IT drive push and pull needs services restart to update the count (SCGCQ01066048, Port of SCGCQ01064904)
- Fixed issue where LSA Allows JBOD Drive having OS to be converted to UG drive, doesnt notify the user on the OS present on JBOD (SCGCQ01067253, Port of SCGCQ01052412)
- Fixed issue where LSA displays "error:Not all values are set successfully" while trying to save power save settings on IMR Ventura. (SCGCQ01067711, Port of SCGCQ01057457)
- Fixed issue where LSA shows blank screen after log in with mutiple controller in the setup (SCGCQ01069360, Port of SCGCQ01068813)
- Fixed issue where intermittent update Ventura firmware hang using LSA ( StorCLI is OK ) (SCGCQ01069565, Port of SCGCQ01038421)
- Fixed issue where user unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01070807, Port of SCGCQ01066154)
- Fixed issue where all the events are not getting downloaded while downloading log from LSA (SCGCQ01145261, Port of SCGCQ01139334)
- Fixed issue where no error message is displayed while importing secure EPD through wrong key (SCGCQ01066088, Port of SCGCQ01063911)
- Fixed issue where user unable to clear or import partial foreign configuration from LSA. (SCGCQ01085466, Port of SCGCQ01069580) 

2.030.000.000 - New Function Only/No fixes
-------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

StorCLI command line tool for anyos



StorCLI (Command Line) Utility for Storage Management

Adapters Supported:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB  Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-16i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller
  - ServeRAID M5210e SAS/SATA Controller for System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5215 SAS/SATA Controller (00JX142)
  - ServeRAID M5115 SAS/SATA Controller (90Y4390)
  - ServeRAID Lenovo Storage Expansion Node (65Y8588)
  - ServeRAID M5110 SAS/SATA Controller for Lenovo System x (81Y4481)
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)

NOTE TO SERVICE - Reference RETAIN #N/A

007.0713.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) 
 - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01556595) 
 - controller show all command is not listing the Battery information(SCGCQ01561689) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) 
 - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) 
 - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) 
 - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) 
 - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) 
 - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) 
 - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) 
 - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) 
 - Spell mistake in error message for hwdev command(SCGCQ01614972) 
 - Coverity defect fix for itctflash file(SCGCQ01616369) 
 - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) 
 - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) 
 - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) 
 - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) 
 - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) 
 - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) 
 - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) 
 - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) 
 - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) 
 - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) 
 - Help content for jbodx show unmap is not present(SCGCQ01790130) 
 - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - storclio command not working to update FW on SATA disk(SCGCQ01918814) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) 
 - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) 
 - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) 
 - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) 
 - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) 
 - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) 
 - Checking in VBAS compliation changes(SCGCQ01630324) 
 - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) 
 - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) 
 - Space need in the output for secure erase(SCGCQ01713604) 
 - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) 
 - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) 
 - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) 
 - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) 
 - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) 
 - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01735493) 
 - Storcli vib update fails across releases.(SCGCQ01761795) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) 
 - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) 
 - Removing the set/show of unmap on JBOD.(SCGCQ01817855) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) 
 - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) 
 - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) 
 - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01595640) 
 - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) 
 - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) 
 - Update help contents for jbod delete(SCGCQ01624605) 
 - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) 
 - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) 
 - Missing punctuation in Perccli delete config message(SCGCQ01698226) 
 - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) 
 - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) 
 - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) 
 - Drive Fw download Coverity fixes(SCGCQ01615074) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) 
 - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) 
 - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) 
 - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) 
 - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) 
 - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) 	
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) 
 - Updating the Diag results as per new API changes(SCGCQ01537255) 
 - Resource leaks,Uninitialized variables(SCGCQ01600311) 
 - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) 
 - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) 
 - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) 
 - Removal of ncurses references for linux makefile(SCGCQ01955544) 
  - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) 
 - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) 
 - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) 
 - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) 
 - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) 
 - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) 
 - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) 
 - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) 
 - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) 
 - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) 
 - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) 
 - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) 
 - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) 
 - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) 
 - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) 
 - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) 
 - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) 
 - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) 
 - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) 
 - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) 
 - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) 
 - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) 
 - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) 
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) 
 - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) 
 - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) 
 - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) 
 - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) 
 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) 
 - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) 
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) 
 - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) 
 - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) 
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) 
 - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) 
 - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) 
 - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) 
 - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) 
 - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) 
 - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) 
 - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) 
 - .(SCGCQ01571935 port of SCGCQ01325052) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) 
 - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) 
 - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) 
 - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) 
 - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) 
 - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) 
 - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) 
 - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) 
 - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) 
 - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) 
 - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) 
 - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) 
 - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) 
 - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) 
 - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) 
 - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) 
 - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) 
 - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) 
 - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) 
 - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 
EnhancementRequests
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) 
 - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) 
 - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) 
 - Need Storcli support drive FW upgrade(SCGCQ01583217) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) 
 - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) 
 - Add a bit for atomic descriptor capable(SCGCQ01965047) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01583223) 
 - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) 
 - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) 
 - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) 
 - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) 
 - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) 
 - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 


007.0525.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects (16)
-.(SCGCQ01753405)
- Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033)
- Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315)
- Enclosure show status command gives success but nothing is shown.(SCGCQ01731280)
- One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763)
- Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927)
- Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612)
- Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548)
- Space need in the output for secure erase.(SCGCQ01713604)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Missing punctuation in Perccli delete config message.(SCGCQ01698226)
- Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265)
- non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272)
- DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443)
- WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279)
- Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752)
- perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719)
- storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990)
- State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444)
- Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355)
- storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816)
- Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795)
- storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493)
- Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849)
- Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269)
- "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017)
- controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704)
- Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749)
- Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493)
- Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354)
- PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418)
- Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616)
- Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223)
- Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972)
- StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602)
- Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983)

EnhancementRequests (30)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730)
-.(SCGCQ01593479)
-.(SCGCQ01761309)
- displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528)
- Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603)


0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence
-------------------

Defects (75)
- Profile Mgmt API Changes.( SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- Enable WB support via API.(SCGCQ01405242)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979)
- Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940)
- storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171)
- Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396)
- Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401)
- Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745)
- Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131)
- Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420)
- Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852)
- Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910)
- Detailed help contents were not present for most of the IT download options..(SCGCQ01483760)
- Spelling errors in the "/cx restart" command..(SCGCQ01486415)
- Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052)
- CLI help does not reflect the new command to create an ePD.(SCGCQ01639583)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- Instance Validation is failing for mentioned commands..(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447)
- Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990)
- PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588)
- Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580)
- Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694)
- PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920)
- PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062)
- Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041)
- Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421)
- Checking in VBAS compliation changes.(SCGCQ01630324)
- PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798)
- Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240)
- Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214)
- MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582)
- Schema addition for "show file=" command.(SCGCQ01461209)
- PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593)
- MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562)
- PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762)
- Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845)
- Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344)
- Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670)
- OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785)
- Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797)
- Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- Incorrect help description for erase and download completeflash commands.(SCGCQ01470263)
- Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802)
- Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833)
- Check for supported pages for firing drive SCSI commands.(SCGCQ01474325)
- No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900)
- IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753)
- Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446)
- Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195)
- Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334)
- Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821)
- UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749)


EnhancementRequests (174)
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType..(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- JSON schema for Drive level commands.(SCGCQ01445435)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
-.(SCGCQ01389581)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- Removing the NMR storcli commands from storcli..(SCGCQ01445268)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
- Removing the NMR storcli commands from storcli..(SCGCQ01445418)
-.(SCGCQ01428114)
-.(SCGCQ01423509)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987)
- Add NVMe device related changes.(SCGCQ01034678)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986)
- Add boot drive selection support in Stor-CLI.(SCGCQ01445896)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424)
-.(SCGCQ01466805)
- StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954)
- StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799)
- Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308)
- Add support for IT Firmware images and IT Completeflash images to "show file=" command.(SCGCQ01436882)

CSETActivities (57)
- StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445)
- Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174)
- Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483)
- Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457)
- Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170)
- Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237)
- SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496)
- Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245)
- This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717)
- Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154)
- Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920)
- Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496)
- Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780)
- Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929)
- Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698)
- Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009)
- Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154)
- storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595)
- Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709)
- Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360)
- Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764)
- Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886)
- Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526)
- Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435)
- Updating readme file(SCGCQ01294583 port of SCGCQ01294570)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453)
- Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412)
- Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234)
- Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605)
- Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562)
- Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703)
- Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628)
- Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447)
- Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256)
- Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552)
- Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578)
- Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900)
- DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749)
- syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675)
- controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689)
- Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481)
- Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460)
- Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156)
- Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214)
- CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640)
- Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618)
- Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793)
- Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255)
- Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754)

0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------
fixes:
- Profile Mgmt API Changes.(SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846)
- Fixing Error Handling issues and Resource leak.(SCGCQ01319395)
- Fix for Libmod files having potential loop errors.(SCGCQ01320336)
- Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003)
- EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452)
- Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604)
- Updated the Help.(SCGCQ01375059)
- controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816)
- Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238)
- storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690)
- Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425)
- Fixing out of bounds in libmods.(SCGCQ01385430)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177)
- Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543)
- PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511)
- Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756)
- Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011)
- Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239)
- Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897)
- Need to handle FW return code change for profile management success case.(SCGCQ01307320)
- Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405)
- PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477)
- Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749)
- CLI reports failure when issuie DPM commands.(SCGCQ01333085)
- PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041)
- Fixing unchecked return values.(SCGCQ01385377)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610)
- Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922)
- LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583)
- Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764)
- Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948)
- Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222)
- This is a syntactical error where a comma was added.(SCGCQ01414744)
- Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208)
- Instance Validation is failing for mentioned commands.(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
- StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018)
- IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046)
- Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219)
- Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438)
- Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771)
- Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
- PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757)
- Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407)
- Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042)
- CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639)
- Removing the memory leaks in dequelog command.(SCGCQ01411544)
- Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758)
- Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934)
- Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Fixing Out of Bounds access and Resource leak.(SCGCQ01304875)
- Inconsistencies between the applications for manage link speed.(SCGCQ01389856)
- Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106)
- Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- StorCLI: Spindown help syntax is misleading.(SCGCQ01421610)
- Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
- StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900)
- Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891)
- Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748)
- Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890)
- Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943)
- Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289)
- StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557)
- Removing the NMR command for setting SCAPVPD.(SCGCQ01389451)
- Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749)

EnhancementRequests:
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType.(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
-.(SCGCQ01421997)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793)
- RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354)
- Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469)
- Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465)
- List pending profile details of the controller.(SCGCQ01346308)
-.(SCGCQ01291037)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- always print StorCLI version information at beginning/top of output.(SCGCQ01396733)
- StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177)
- New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
-.(SCGCQ01428114)
- Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646)
- Add NVMe device related changes.(SCGCQ01034678)
- Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301)
- Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079)
- Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)

CSETActivities:
- StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018)
- MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830)
- Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790)
- MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315)
- MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798)
- Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785)
- SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496)
- Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610)
- Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900)
- CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 )
- Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789)
- Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152)
- Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673)
- Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381)
- Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320)
- MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757)
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529)
- MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520)
- Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274)
- MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453)
- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843)
- Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891)
- CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 )
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177)
- Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604)
- Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843)
- Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152)
- C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830)
- Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495)
- Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145)
- Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484)
- [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914)
- Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728)
- MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756)
- MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493)

0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
 - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536)
 - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913)
 - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948)
 - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629)
 - Code clean up in libmods and sysefi files are added(SCGCQ00359998)
 - Storcli is returning error with show(SCGCQ00360040)
 - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814)
 - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216)
 - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717)
 - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455)
 - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522)
 - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097)
 - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248)
 - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622)
 - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735)
 - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000)
 - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155)
 - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735)
 - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364)
 - portings of AdpRestart command(SCGCQ00378135)
 - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828)
 - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104)
 - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303)
 - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789)
 - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832)
 - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350)
 - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610)
 - SWR_1.34(SCGCQ00442652)
 - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502)
 - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583)
 - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843)
 - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560)
 - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201)
 - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579)
 - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935)
 - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835)
 - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123)
 - Storcli : unable to set patrol read delay(SCGCQ00645195)
 - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324)
 - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742)
 - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131)
 - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171)
 - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192)
 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505)
 - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647)
 - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770)
 - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178)
 - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183)
 - Adapters are not listed in sorted order.(SCGCQ00759969)
 - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398)
 - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752)
 - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663)
 - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712)
 - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243)
 - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789)
 - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882)
 - "cpybck" help is not coming in Legends(SCGCQ00784808)
 - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400)
 - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232)
 - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374)
 - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394)
 - .(SCGCQ00800878)
 - Deallocation of the same memory more than once(SCGCQ00802031)
 - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588)
 - Out-of-bounds access and array delete misuse(SCGCQ00804680)
 - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547)
 - Not able add new VD in Drive Group(SCGCQ00813314)
 - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939)
 - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049)
 - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299)
 - storcli /call show all fails with "command invalid"(SCGCQ00830269)
 - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342)
 - Profile Mgmt API Changes(SCGCQ00883008)
 - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417)
 - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738)
 - The code had events with repetitive ID and some structures clashing(SCGCQ00948535)
 - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835)
 - 800C error when execting Get MFC default function(SCGCQ01037840)
 - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936)
 - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284)
 - No ISE Capable field(SCGCQ01148693)
 - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175)
 - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698)
 - Fixing Resource leaks(SCGCQ01205356)
 - resource validation before de referencing(SCGCQ01206104)
 - Fixing resource leaks in libmods(SCGCQ01208044)
 - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393)
 - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414)
 - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473)
 - Fix for resource leak in system config show(SCGCQ01210133)
 - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415)
 - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383)
 - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923)
 - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217)
 - NVMe PD SMART DATA shows all 0's(SCGCQ01236052)
 - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715)
 - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381)
 - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687)
 - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688)
 - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928)
 - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421)
 - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632)
 - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445)
 - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336)
 - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979)
 - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883)
 - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094)
 - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474)
 - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620)
 - Some sparc structures missing for storcli.(SCGCQ00504585)
 - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761)
 - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658)
 - storecli reports wrong size on 3000MB VD(SCGCQ00644545)
 - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962)
 - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672)
 - Add support bits for uneven-span and SSHA support(SCGCQ00755063)
 - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101)
 - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924)
 - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290)
 - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959)
 - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385)
 - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937)
 - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714)
 - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759)
 - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347)
 - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363)
 - Storcli errors are printing in a different line.(SCGCQ00771626)
 - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302)
 - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332)
 - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577)
 - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800)
 - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357)
 - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202)
 - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761)
 - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393)
 - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335)
 - Resource leak(SCGCQ00804745)
 - .(SCGCQ00811452)
 - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672)
 - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205)
 - Fix for profile management support check bit(SCGCQ01208103)
 - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411)
 - Unified Storcli: Fixing resource leak issues(SCGCQ01209413)
 - SAS3.5 Ventura(SCGCQ01219196)
 - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153)
 - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169)
 - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376)
 - Need to handle FW return code change for profile management success case(SCGCQ01307320)
 - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263)
 - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644)
 - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663)
 - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978)
 - storcli /c0 show is not listinf SWR controller(SCGCQ00454971)
 - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116)
 - Raptor Galaxy : Storcli(SCGCQ00475562)
 - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981)
 - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771)
 - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763)
 - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073)
 - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800)
 - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416)
 - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775)
 - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174)
 - storelib header file changes porting(SCGCQ00609942)
 - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023)
 - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969)
 - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070)
 - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000)
 - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187)
 - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806)
 - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918)
 - Missing the Display of the property temperatureCtrl.(SCGCQ00792264)
 - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760)
 - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336)
 - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206)
 - Memory not freed which can cause leak(SCGCQ00804554)
 - Varailble need to be freed before returning in all failure case(SCGCQ00804650)
 - IDA show incorrect RAID controller type information(SCGCQ00806966)
 - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197)
 - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372)
 - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111)
 - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464)
 - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723)
 - Removing Unused and logically dead code in storcli(SCGCQ01204045)
 - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492)
 - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685)
 - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083)
 - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
 - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332)
 - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100)
 - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043)
 - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956)
 - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370)
 - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287)
 - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672)
 - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181)
 - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862)
 - CPLD(SCGCQ00787705)
 - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233)
 - rlListPtr is not handled properly in failure case(SCGCQ00796227)
 - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392)
 - LDViewMirror is giving segmentation fault(SCGCQ00830435)
 - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758)
 - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321)
 - Checking in compilation error for Libmods(SCGCQ00919973)
 - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356)
 - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055)
 - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407)
 - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101)
 - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553)
 - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709)
 - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745)
 - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950)
 - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070)
 - debug prints are present when issuing /co/eall show(SCGCQ00475815)
 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543)
 - Verify StorCLI warns on destructive operations(SCGCQ00712982)
 - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584)
 - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691)
 - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358)
 - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200)
 - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211)
 - Incorrect sizeof expression in dcmdprm(SCGCQ00793354)
 - Non-array delete for objects in rmdatamf(SCGCQ00793361)
 - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420)
 - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663)
 - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
 - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736)
 - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583)
 - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096)
 - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306)
 - PD related information missing for NVMe drives(SCGCQ01126564)
 - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365)
 - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854)
 - StorCLI(SCGCQ01274554)
 - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911)
 - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070)
 - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665)
 - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107)
 - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008)
 - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605)
 - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
 - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402)
 - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205)
 - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334)
 - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342)
 - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311)
 - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117)
 - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368)
 - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844)
 - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353)
 - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082)
 - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437)
 - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721)
 - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236)
 - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289)
 - Help for Compare linkspeed is not complete(SCGCQ01275454)
 - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037)
 - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491)
 - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067)
 - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426)
 - Libmod changes to support profile management(SCGCQ01048228)
 - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627)
 - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876)
 - Ventura PH3(SCGCQ01253012)
 - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455)
 - coverity removing out of bounds reads from code(SCGCQ01280460)
 - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999)
 - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085)
 - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234)
 - Resource leak in VdDataMf scanPartitions(SCGCQ00793363)
 - Storcli can't create AHCI LDs(SCGCQ00897637)
 - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676)
 - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024)
 - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214)
 - Detailed help missing for IT erase commands(SCGCQ01275474)
 - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671)
 - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453)
 
Enhancement
 
 - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167)
 - New fault code for routine synchronous reset(SCGCQ01264142)
 - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358)
 - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050)
 - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414)
 - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228)
 - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796)
 - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215)
 - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613)
 - API changes for CR55(SCGCQ01222700)
 - API change for Simplified RAID10 Creation(SCGCQ01222698)
 - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406)
 - API changes for PR SCGCQ01139678(SCGCQ01215334)
 - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 - API changes for PR SCGCQ01127742(SCGCQ01203751)
 - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 - MR 6.12(SCGCQ01146597)
 - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251)
 - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344)
 - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627)
 - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969)
 - MPI 2.5: Add new connector types(SCGCQ01085073)
 - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360)
 - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162)
 - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885)
 - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208)
 - MPI 2.5: update copyright info(SCGCQ00728066)
 - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829)
 - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820)
 - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175)
 - Add type BIOS for HashImageType.(SCGCQ00566306)
 - Identify physical location of a target device(SCGCQ00523879)
 - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817)
 - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293)
 - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819)
 - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437)
 - Allow Protection Information bit for IR Volume Create(SCGCQ00385306)
 - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551)
 - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271)
 - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270)
 - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266)
 - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260)
 - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506)
 - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383)
 - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439)
 - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131)
 - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055)
 - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759)
 - MPI 2.6: SOP Encapsulated request(SCGCQ00264755)
 - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183)
 - Libmods changes for EFI support for Unified storcli(SCGCQ00923719)
 - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101)
 - OEL Support for SPARC(SCGCQ00787923)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007)
 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477)
 - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399)
 - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735)
 - MPI 2.6: add IO Unit Control Request(SCGCQ00345258)
 - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272)
 - MPI 2.6: Enclosure Management(SCGCQ00345273)
 - Device Info field for PCIe devices(SCGCQ00353339)
 - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843)
 - MPI 2.6: new family values for ProductID fields(SCGCQ00360952)
 - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600)
 - Modified address space bits(SCGCQ00397136)
 - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563)
 - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568)
 - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572)
 - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577)
 - MPI 2.6: Add NVMe SGL support(SCGCQ00398256)
 - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541)
 - MPI 2.6: System Interface Register Set update(SCGCQ00464402)
 - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292)
 - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998)
 - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281)
 - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070)
 - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869)
 - MPI 2.6: Add new FLASH region types(SCGCQ00619371)
 - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271)
 - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957)
 - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527)
 - MPI 2.6: Extend Task Management(SCGCQ00686666)
 - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177)
 - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600)
 - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389)
 - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088)
 - MPI 2.6: add PCI Device ID's(SCGCQ00828497)
 - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588)
 - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827)
 - MPI 2.6: Update Flash Signature.(SCGCQ00852831)
 - profile management API(SCGCQ00867953)
 - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169)
 - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328)
 - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262)
 - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740)
 - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256)
 - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336)
 - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213)
 - MPI 2.6: Remove all SOP references(SCGCQ00925839)
 - Change library name to SLIT(SCGCQ00933175)
 - Ventura: de-feature AHCI(SCGCQ00941620)
 - MPI 2.6: Remove all AHCI references(SCGCQ00948258)
 - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955)
 - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638)
 - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619)
 - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104)
 - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930)
 - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826)
 - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027)
 - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687)
 - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473)
 - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741)
 - mega api changes for ibuttonless PR(SCGCQ01059740)
 - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009)
 - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374)
 - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821)
 - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340)
 - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549)
 - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837)
 - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839)
 - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127)
 - MPI 2.6: Add new clean tool options(SCGCQ01141732)
 - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583)
 - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725)
 - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092)
 - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367)
 - MPI 2.5: Signed images for FWDownload(SCGCQ00469990)
 - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512)
 - Display the Storelib version in the show command.(SCGCQ01286063)
 - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457)
 - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496)
 - Add support to allow Device names greater than 107(SCGCQ01039328)
 - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636)
 - Enable SED on JBOD(SCGCQ00755527)
 - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230)
 - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051)
 - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474)
 - Implemented the diag results to print on console(SCGCQ00525321)
 - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742)
 - MWCLI. Add HA support into storcli(SCGCQ00352120)
 - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668)
 - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607)
 - Add NVMe device related changes(SCGCQ01034678)
 - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665)
 - Complete 240VD support for utilities(SCGCQ00693042)
 - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287)
 - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311)
 - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793)
 - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715)
 - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821)
 - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146)
 - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204)
 - UDK Support for EFI(SCGCQ00795150)
 - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171)
 - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872)
 - Provide a way to enable or disable 512E using Applications(SCGCQ00351234)
 - Refer attached design doc(SCGCQ00349599)
 - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)
 - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050)
 - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217)
 - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344)
 - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473)
 - RRB 71(SCGCQ00750164)
 - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081)
 - SED/FDE changes for storcli Synchro(SCGCQ00632240)
 - ASD- StorCLI(SCGCQ00467863)
 - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209)
 - PERC 10 WIndows Support(SCGCQ01213160)
 - PERC 10 WIndows Support(SCGCQ01213157)
 - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080)
 - Megacli/storcli support for lmrc driver(SCGCQ00433703)
 - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093)
 - Uneven span support is added in StorCLI.(SCGCQ00349548)
 - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391)
 - Add EFI support for the manufacturing command to program.(SCGCQ01191095)
 - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216)
 - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476)
 - Monitoring Drive performance and predictive failure(SCGCQ00817977)
 - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118)
 - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237)
 - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987)
 - Functionality to extract field value from new API changes(SCGCQ00794841)
 - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815)

0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.

1.20.20 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227)
- Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335)
- Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866)
- Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811)
- Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074)
- Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438)
- Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663)
- Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140)
- Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401)
- Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258)
- Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358)
- Fixed an issue where storcli does not display description on command success - (SCGCQ01023973)
- Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081)
- Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945)
- Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534)
- Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430)
- Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535)
- Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218)
- Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102)
- Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484)
- Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534)
- Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745)
- Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757)
- Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895)
- Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068)
- Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105)
- Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314)
- Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646)
- Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899)
- Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101)
- Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120)
- Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669)
- Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997)
- Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082)
- Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011)
- Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071)
- Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117)
- Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416)
- Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387)
- Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154)
- Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907)
- Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447)
- Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139)
- Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493)
- Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500)
- Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028)
- Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669)
- Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536)
- Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554)
- Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode  - (SCGCQ01043063)
- Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322)
- Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608)
- Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994)
- Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298)
- Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300)
- Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088)
- Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805)
- Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035)
- Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084)
- Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706)
- Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613)
- Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775)
- Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973)
- Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830)
- Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940)
- Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786)
- Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464)
- Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466)
- Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876)
- Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415)
- Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985)
- Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968)
- Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027)
- Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756)
- Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306)
- Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841)
- Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876)
- Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525)
- Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798)
- Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620)
- Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204)
- Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274)
- Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667)
- Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604)
- Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055)
- Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533)
- Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614)
- Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474)
- Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758)
- Fixed an issue where some commands may not report success on success - (SCGCQ01050695)
- Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241)
- Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116)
- Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773)
- Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500)
- Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378)
- Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493)
- Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205)
- Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864)
- Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540)
- Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766)
- Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178)
- Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305)
- Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482)
- Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514)
- Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493)
- Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642)
- Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528)
- Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477)
- Fixed an issue where installaton of storclio may fail - (SCGCQ00952422)
- Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981)
- Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790)
- Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315)
- Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178)
- Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865)
- Fixed an issue where EPD details may not show in "show all" command  - (SCGCQ00921937)
- Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624)
- Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489)
- Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330)
- Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837)
- Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484)
- Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697)
- Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461)
- Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597)
- Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760)
- Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891)
- Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993)
- Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617)
- Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault"  - (SCGCQ01020010, Port of SCGCQ01019547)
- Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212)
- Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145)
- Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101)
- Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181)
- Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177)
- Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789)
- Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable  - (SCGCQ01143941, Port of SCGCQ01026187)
- Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307)
- Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download  - (SCGCQ01110108, Port of SCGCQ00934755)
- Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211)
- Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584)

Enhancements:
- Added the personality change command was not present - (SCGCQ00850610)
- Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220)
- Added multipath support in EPD configuration options - (SCGCQ01015758)
- Added additional CPU support on EFI platform - (SCGCQ01026250)
- Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304)
- Added personality change features - (SCGCQ01111930)
- Added VF-queue depth mode settings - (SCGCQ00907072)
- Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320)
- Added Secure Erase support to JBOD and System drives - (SCGCQ00929757)
- Added a JBOD entity for various operations - (SCGCQ01047229)
- Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064)
- Added more specific error messages in some circumstances - (SCGCQ00920034)
- Added new compilation environment and makefiles - (SCGCQ00920058)
- Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739)
- Added support for drive microcode update Modes E and F - (SCGCQ01047223)
- Added code to display JBOD personality - (SCGCQ01146775)
- Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338)
- Added new erase type called Crypto - (SCGCQ01050618)
- Added new command to set the multiInit EPD parameter - (SCGCQ01080273)
- Added support for drive microcode update through parallel loading - (SCGCQ01024964)
- Added support for EPD creation - (SCGCQ00887664)
- Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414)


1.18.11 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705)
- Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785)
- Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612)
- Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196)
- Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339)
- Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620)

Enhancements:
- Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662)
- Added the support to set and clear the transport on a DG (SCGCQ00920046)
- Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318)
- Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795)
- Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030)
- Provide a more descriptive port enumeration (SCGCQ00854620)
- Add support to enable/Disable of Large IO Support (SCGCQ00894644) 

1.16.14 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617)
- Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176)
- Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715)
- Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755)

1.16.10 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617)
- Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470)
- Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914)
- Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143)
- Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429)
- Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770)


1.14.12 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Incorporated StorCLI MegaRAID 6.6 stream

Enhancements:
- Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171)
- Added consistent sorting of controllers using bus, device, function (SCGCQ00696872)
- Added ability to enable or disable 512e support (SCGCQ00351234)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527)
- Added ability for VMWare version to be run from any directory (SCGCQ00642230)
- Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477)
- Added ability to create a RAID00 (SCGCQ00350668)
- Added ability to display the Patrol Read Start Time (SCGCQ00564474)
- Added learn cycle progress information in show learn command (SCGCQ00644984)
- Added support for uneven spans (SCGCQ00349548)
- Added support for lmrc driver (SCGCQ00433703)
- Added 240 Virtual Drive support (SCGCQ00693042)
- Improved Punctured Block logging (SCGCQ00342399) 

1.12.15 - Moderate Impact/Low Probability of Occurrence
-------
Fix(es):
 - Prevent storCLI from allowing users to enable JBOD mode on
   controllers that do not support JBOD mode.
 - Updated CACHEBYPASS command to line up with user expectation.  When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass.

1.07.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M1215 SAS/SATA Controller
Fix(es):
 - Fixed an issue where segmentation faults may occur in Linux.
 - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS.
 - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying.

1.04.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M5210e and ServeRAID M5210
Fix(es):
 - Fixed an issue where a command failure results in subsequent commands and actions failing.
 - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR.
 - Added help file for for storcli /cx/dx set security
 - Fixed an issue where the "show ctrlcount help" command is not displaying properly.
 - Fixed an issue where a failure is displayed in the output for querying dimmer switch information.
 - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM.
 - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives.
 - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed.
 - Synced the pause pr command with show pr command to show correct PR Current State.
 - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property.

1.03.11 - Initial release
-------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

MegaRAID Storage Manager Application



MegaRAID Storage Manager Application

Supported controllers:
  - N2226 SAS/SATA HBA for Lenovo System x (00AE916)
  - N2225 SAS/SATA HBA for Lenovo System x (00AE912)	 
  - N2215 SAS/SATA HBA for Lenovo System x (47C8676)
  - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x
  - ServeRAID M1210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5225 SAS/SATA Controller for Lenovo System x (00AE938)
  - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x
  - N2125 SAS/SATA HBA for Lenovo System x
  - N2115 SAS/SATA HBA for Lenovo System x
  - Lenovo PureFlex System Storage Expansion Node
  - Onboard LSI 2004 SAS/SATA Controller
  - ServeRAID H1110 SAS/SATA Controller for Lenovo System x (81Y4492)
  - ServeRAID M5210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)
  - ServeRAID M5115 SAS/SATA Controller for Lenovo System x (90Y4390)
  - ServeRAID M1115 SAS/SATA Controller for Lenovo System X (81Y4448)


NOTE TO SERVICE - Reference RETAIN #N/A


17.05.01.03 - Moderate Impact/Low Probability of Occurrence
-----------
Enhancements:
- MSM: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564578) 


17.05.01.02	- Moderate Impact/Low Probability of Occurrence
-----------

17.05.01.00 - Moderate Impact/Low Probability of Occurrence (Suggested)
-----------

16.05.04.01 - Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Fixed an issue where MSM was not flashing 8MB FW file on M5200 series Controllers. (SCGCQ00996185)
 - Fixed an issue where Dashboard view and Main View for Create Virtual Drive option are inconsistent when all drives are configure as JBOD (SCGCQ01054496)
 - Fixed an issue where MSM was not able set secure JBOD (SCGCQ01064281)
 - Fixed an issue where MSM cannot flash M1115 or M1015 controller firmware. (SCGCQ01125515)
 - Fixed an issue where event Block Recovery is skipped due to dirty OCR and "Please reboot the system" not seen after dirty OCR." (SCGCQ00989881)
- Fixed an issue where MSM server profile shows repetitive headlines and inconsistent information for virtual drives (SCGCQ00996188)
- Fixed an issue where MSM hang is observed while DIFF PD is become shielded state and then unconfigured bad. (SCGCQ00553738)
 - Added generic error message when update iMR image on MR controller. (SCGCQ00934328)
 - Corrected inconsistency in Create SSCVD option across MSM tabs. (SCGCQ01013993) 
- Fixed an issue where virtual drive information header printed multiple times in the profile summary page. (SCGCQ01062382)
- Fixed an issue where background operations appear in profile summary without any table header. (SCGCQ01064081) 
- Fixed an issue where after IR controller firmware flash the popup for the update status is not displayed. (SCGCQ00916747)
 - Fixed an issue where MSM displayed an option to create Virtual drive even when there are no configurable disks present in RAID mode. (SCGCQ00945155)
- Fixed an issue where the Creating CacheCade SSD Caching menu option is not available. (SCGCQ01117219)
- Fixed an issue where connecting the expander to IR2 controller, drive ID info was not correctly displayed when the drive is inserted or deserted (SCGCQ01155781 Port of SCGCQ00898807)
 - Fixed an issue where title bar was missing, when trying to view the personality from SDS to Raid (SCGCQ00941885)
 - Fixed an issue where the create CCVD option was still seen after MAX (2TB) CCVD creation. (SCGCQ00952332)
 - Fixed an issue where the MSM showed wrong information about the DG in the summary page of RLM operation. (SCGCQ01039111)
 - Fixed an issue where MSM was not allowing to flash ctrlH on iMR controller. (SCGCQ01056002)
 - Fixed an issue where SWR for RHEL 6.8, driver version info was not aligned properly in MSM server profile. (SCGCQ01109158)
 - Fixed an issue where MSM showed inconsistent info for degraded spanned RAID Level DG's in Replace PD operation (SCGCQ01034766)
 -  Added code to disable CreateVD menu when recon is running in case of JBOD (SCGCQ00996752)
 - Fixed an issue where right clicking on the VD was not opening the change properties (SCGCQ00987893 Port of Defect - SCGCQ00952349
- Fixed an issue where leaving MegaRAID Storage Manager GUI open for an extended period of time (3 to 4 days), the GUI stopped automatically refreshing and monitor stopped updating AEN's. (SCGCQ01085197 Port of Defect - SCGCQ00946664)

Enhancements:
 - Added SLIR error codes and corresponding error messages handling to MSM. (SCGCQ00933586)
 - Added new operations at DG level to support MR_DCMD_LD_SET_TRASPORT_READY and MR_DCMD_LD_CLEAR_TRASPORT_READY (SCGCQ00920044)
 -  Do not allow VD creation on Removal Ready PD (SCGCQ01027492 Port ofSCGCQ00988701)


15.11.53.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:

 - No functional changes.


15.11.50.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:

 - Updated OpenSSL to address FREAK vulnerability (SCGCQ00877531)
 - Updated Java to address FREAK vulnerability (SCGCQ00877538)
 - Fixed an issue where no mnemonics/shortcut keys are available for Make Unconfigured Good and Manage Link Speed menu operations (SCGCQ00711990)
 - Fixed an issue where MegaRAID Storage Manager does not display logs after saving logs in a text file in VMware ESXi (SCGCQ00834428)
 - Fixed an issue where MegaRAID Storage Manager is showing "Sequence number is out of sync" warning message for "Secure using FDE" operation (SCGCQ00836494)
 - Fixed an issue where MegaRAID Storage Manager did not report the correct Windows operating system name/version (SCGCQ00854632)
 - Fixed an issue where the option to set critical and fatal events reports in the next reboot is not present (SCGCQ00866188)
 - Fixed an issue where Phy Count was being shown for Enclosure Physical Disks when it should not be (SCGCQ00869437)
 - Fixed an issue where a user is unable to View Server Profile (SCGCQ00873250)
 - Fixed an issue where BBU property displays "status = Unknown" when Supercap battery is in failed state (SCGCQ00887351)
 - Fixed an issue where there is no option to close the host view window (SCGCQ00897401)
 - Fixed an issue where MegaRAID Storage manager does not allow the option to uncheck the JBOD drive which has an operating system or file system on it (SCGCQ00897404)
 - Fixed an issue where Controller Info may not be displayed when CacheCade is enabled and the firmware supports 240 Virtual Drives (SCGCQ00898869)
 - Fixed an issue where the scroll bar in the Group Progress window may disappear when starting/suspending Consistency Check on multiple Virtual Drives  (SCGCQ00900408)
 - Fixed an issue where different information is shown in the "Create VD Summary Window" when creating in Simple Mode, and Capacity Alignment is not correct (SCGCQ00900416)
 - Fixed an issue where Virtual Drive numbering may be incorrect when creating more than three Virtual Drives (SCGCQ00902923)
 - Fixed an issue where Patrol Read may not be able to start on Partial-Size Virtual Drives (SCGCQ00918881)
 - Fixed an issue where Virtual Drives may not appear under the Logical tab after upgrading firmware and importing a configuration (SCGCQ00927688)
 - Fixed an issue where the wrong Operating System architecture may be displayed under Server Info (SCGCQ00928640)
 - Fixed an issue where "Create CacheCade VD" menu is displayed with max Logical Drives set, causing the operation to fail (SCGCQ00928753)
 - Fixed an issue where some windows may appear off-screen (SCGCQ00928758)
 - Fixed an issue where events are missing "Hidden" state of Virtual Drives (SCGCQ00933592)
 - Fixed an issue where Physical Drive information in Event Information is blank, but is correctly displayed in Backplane Properties (SCGCQ00933603)
 - Fixed an issue where destination drive is not listed under Logical View during a Copyback (SCGCQ00934374)
 - Fixed an issue where the Write Policy may not be correct after creating a Virtual Drive (SCGCQ00934377)
 - Fixed an issue where "Next Learn Cycle Time & Learn Period" may not be displayed when battery supports Transparent Learn (SCGCQ00934380)
 - Fixed an issue where "Online Firmware Update in progress" is showing after controller reset using storcli completes (SCGCQ00934505)
 - Fixed an issue where logs saved as Text file are missing Enclosure IDs in the events (SCGCQ00934595)
 - Fixed an issue where Operating System and Health fields are showing Unknown from the remote server Discovery page (SCGCQ00934721)
 - Fixed an issue where an application restart pop-up may occur while downgrading firmware, citing 240 Virtual Drive support (SCGCQ00939249)

Enhancements:

 - Enhanced the port enumeration naming scheme (SCGCQ00854619)
 - Added ability to select a range of events to parse when generating Alert Notifications (SCGCQ00854627)
 - Added ability to report controller flash device health status (SCGCQ00887610)
 - Changed Consistency Check / Patrol Read overlap message from Warning to Informational (SCGCQ00887611)
 - Added ability to handle MFI and SL error codes with corresponding error messages (SCGCQ00942678)


15.05.01.52 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Fixed an issue where MSM may not report HDD temperature information for drives in slot 0 connected to SWRAID - (SCGCQ00895878, Port of SCGCQ00867490)
 - Fixed an issue where Japanese Language packs may cause email alerts to be garbled - (SCGCQ00890256)
 - Fixed an issue where MSM may have a garbled character instead of 'TM' by using UNICODE \u2122 instead of ASCII 0x99 - (SCGCQ00880993)
 - Fixed an issue where event ID 150 descriptions were not consistent between the alert strings and the event properties - (SCGCQ00881952)

Enhancements:
 - Provide more descriptive port enumeration based on width of the port (SCGCQ00895884, Port of SCGCQ00854619)


15.05.01.51 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Corrected the output for the key MSG_ASSOCIATED_SSCDDELETE_TEXT1 value with corresponding unicode for @TM Symbol in resource files (SCGCQ00880993)
 - Corrected the inconsistency in description for Event ID 150 between alert Strings.xml and MR_Events.properties


15.03.01.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes: 
 - OpenSSL security fixes

14.11.01.05 -  High Impact/High Probability of Occurrence
-----------
Fixes:
- Incorporated MSM MegaRAID 6.6 stream
- Fixed an issue where "Remove JBOD" option may not warn client even if the drive has a filesystem (SCGCQ00704645)
- Updated the StorCLI within MSM to the latest (SCGCQ00707316)
- Fixed an issue where MSM may still provide option to create a VD even after max VDs have been created (SCGCQ00707466)
- Fixed an issue where Enclosure details may not be shown in ViewServerProfile (SCGCQ00709507)
- Fixed an issue where "Select All" and "Start" buttons are enabled in Consistency Check window curing CC on only one VD (SCGCQ00740485)
- Fixed some null pointer dereferences in MSM EventXMLFormation (SCGCQ00757780)
- Fixed an issue where MSM may allow a CacheCade VD to be recreated with Always Write Back option (SCGCQ00759986)
- Fixed an issue where the message for Dedicated Hot Spare is missing the VD name (SCGCQ00770874)
- Fixed an issue where the Create Virtual Drive icon is still active when it shouldn't be (SCGCQ00772351)
- Fixed an issue where MSM popup showing Patrol Read progress even after setting Max Concurrent PDs for Patrol Read to 0 (SCGCQ00774583)
- Fixed an issue where "Initialization Aborted" message does not show up in MSM  (SCGCQ00706130)
- Fixed an issue where a Bootable JBOD with the OS on it shows as eligible for conversion to Unconfigured Good (SCGCQ00742001)
- Fixed an issue where Null Pointer Exceptions were being thrown in the AdapterMenu (SCGCQ00757770)
- Removed unused CIMPlugin dependencies in CacheCacde and modify the folder structures for respective OSes (SCGCQ00757819)
- Fixed an issue where a user may be able to login twice in a point of time as Administrator Full Access (SCGCQ00760231)
- Fixed an issue where discovery may fail after MSM installation with 1024bit keys on RHEL (SCGCQ00787334)
- Fixed an issue where the Graphical view for Enclosures may not be correct (SCGCQ00717047)
- Fixed an issue where MSM cannot create any RAID level if the drives are selected one by one (SCGCQ00734568)
- Fixed an issue where the shortcut key for Manage Link Speed menu option is not present (SCGCQ00709792)
- Fixed an issue where MSM shows an incomplete window for Advanced Software Options when using shortcut key as opposed to regular menu option (SCGCQ00713213)
- Fixed an issue where the Select All button is enabled in the Initialize window when only one R6 VD is available with partially degraded mode (SCGCQ00759357)
- Fixed an issue where MSM may throw "Requested command cannot be completed because resources are already in use" or "Invalid array specified"when creating arrays in specific circumstances (SCGCQ00762640)
- Fixed an issue where MSM may report CacheCade VD has been deleted even though it is still being deleted by firmware (SCGCQ00777823)
- Fixed some null reference issues (SCGCQ00766100)
- Fixed an issue where volume creation fails in MSM if the controller has firmware that supports 240 VDs (SCGCQ00664507)
- Fixed an issue where Consistency check cannot be scheduled in 64-bit Linux managing an ESXi host (SCGCQ00757859)
- Fixed an issue where "Select All" and "Start" buttons are enabled in Initialization window during Init on only one VD (SCGCQ00727600)
- Fixed an issue where one is unable to create a second VD in MSM through Dashboard "Create Virtual Drive" link (SCGCQ00766971)
- Fixed an issue where cannot uninstall MSM via uninstaller.sh script in RHEL6.5 (SCGCQ00691368)
- Fixed an issue where MSM fails to save Host Configuration Settings (SCGCQ00691421)
- Fixed an issue where alert strings for events 502, 512, 513 and 514 may be wrong (SCGCQ00698294)
- Fixed an issue where there may be a fatal error when logging in via Server button on top and trying to refresh using the option button on top (SCGCQ00727445)
- Fixed an issue where updating MSM may fail in Windows (SCGCQ00727990)
- Fixed an issue where MSM may display an invalid field (Parity Size) for R00 (SCGCQ00687943)
- Fixed an issue where a SuperCap reported as Bad may still show as Optimal (SCGCQ00785419)
- Fixed an issue where "Prepare for Removal" on PD may not work on PD with pending operations (SCGCQ00784866)
- Fixed an issue where R6 option may be displayed during migration of a 31-drive R0 (SCGCQ00703809)
- Fixed an issue where event log shows "null" instead of correct VD where Snapshot schedule properties have changed (SCGCQ00795792)
- Fixed an issue where R1 option may be displayed during migration of a 7-drive R0 (SCGCQ00694232)
- Fixed an issue where MSM may not login to remote host in the favorite list (SCGCQ00692364)
- Fixed an issue where entering security key in MSM to unlock PD fails to import afterwards (SCGCQ00785420)
- Fixed an issue where MSM may scroll additional Sense Info constantly after refreshing screen for SATA (SCGCQ00789079)
- Fixed an issue where Consistency Check is grayed out after disabling through MSM and can't be reenabled through MSM (SCGCQ00795183)
- Fixed an issue where one is unable to stop the MSMFramework service (SCGCQ00756996)
- Fixed an issue where Create Virtual Drive option is lost in MSM (SCGCQ00822350)
- Fixed an issue where there may be many blank messages in the MSM logs on controllers with multiple VDs (SCGCQ00827667)
- Fixed an issue where timestamps are incorrect in TTY logs saved through MSM (SCGCQ00829187)
- Fixed an issue where after creating a spanned VD, MSM creates duplicate drive groups (SCGCQ00830891)
- Fixed an issue where "TIME = Not Available" message appears in text file of events saved through MSM (SCGCQ00832354)
- Fixed an issue where during install MSM may show erroneous "major upgrade" warnings and errors and asks for restart of the system (SCGCQ00817865)
- Fixed an issue where MSM may not import SED / FDE Foreign Config using previous security key (SCGCQ00823013)
- Fixed an issue where Patrol Read and Consistency Check schedule overlap errors were listed as Warnings instead of Informational (SCGCQ00821374)
- Fixed an issue where the MSM log may be flushed after host reboot (SCGCQ00800288)

Features/enhancements
- Added the ability to display PCI Domain information, instead of just PCI Bus and Device (SCGCQ00712488)
- Added latest Pegasus library v2.13 (SCGCQ00650093)
- Recompiled Pegasus libraries for Windows with the latest OpenSSL (SCGCQ00729736)
- Added support for 2048bit RSA keys (SCGCQ00696866)
- Added support for reporting drive temperatures for all SAS/SATA HDDs/SSDs (SCGCQ00650088)
- Added PFK support for SSHA (SCGCQ00707653)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00821360)


14.05.02.03 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes: 
 - MSM reports full version nubmer to Lenovo comparison tools.
 - Fixed an issue where MSM alert for event ID 81 and ID 114 do not give notification.
 - Fixed an issue where MSM could not uninstall via uninstaller.sh script in RHEL 6.5.
 - Fixed an issue where MSM is not showing the "Selected Firmware Version" during online firmware update.
 - Fixed an issue where server status doesn't changes accordingly with IR2 controller in MSM login page.
 - Fixed an issue where MSM login screen missing host and OS name.
 - Fixed an issue where menu items load configuration and scan configuration are highlighted when the controller is in safe mode.
 - Fixed an issue where inconsistent write policy during EVS creation in MSM.
 - Implement SuperCap deep dive action items in the firmware and applications
 - Fixed an issue where MSM simple create virtual disk dialog box disappears for ServeRAID H1110
 - Fixed an issue where virtual drive erase option is not found.
 - Fixed an issue where MSM is throwing error code 0 x 32.
 - Fixed an issue where starting patrol read throwing error '0x58' when virtual disk erase is running.
 - Fixed an issue where MSM not reporting events for changes that occurred to IR volumes during power off.
 - Fixed an issue where MSM displays unsupported SATA drives for replace operation for regular 512n drives - Single Node.
 - Fixed an issue where MSM displays invalid field name for disabling data protection.
 - Fixed an issue where 4K virtual disk size is wrong during import of 64 virtual disk s - Single Node.
 - Fixed an issue where MSM need to return error when destroy key on peer node with existing secure virtual disk.
 - Fixed an issue where the user cannot uninstall MSM without xterm installed under Linux.
 - Fixed an issue where MSM login screen missing the domain ID column at the most right.
 - Resolved OpenSSL vulnerabilities.

13.11.01.07  - Initial release
-----------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved