Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): System x3850 X6 / x3950 X6 (6241)
Targeted Operating System: RHEL6.9
YUM Repository Build Date: 2019_04_23

YUM Repository Release Version: 19A

Device:
N2125 SAS/SATA HBA

Device Product Guide

Part Number: 46C9010
Feature Code: A3YY
PCIe Sub Vendor ID: 0x1014
PCIe Sub Device ID: 0x040D


Release History:
Release: 19A
Change History Documents
Firmware Firmware Name Version
BIOS/FW/UEFI Update for N2125 SAS/SATA Controller n2125-1.20.02-4
Drivers Driver Name Discreate Package Download Version
InBox Driver provided by Linux Distro install supported
Utilities Utility Name Version
MegaRAID Storage Manager Application 17.05.01.03
SAS2IRCU (Command Line) Utility for Storage Management sas2ircu-20.00.00.00

Release: 18D
Firmware Firmware Name Version
BIOS/FW/UEFI Update for N2125 SAS/SATA Controller n2125-1.20.02-4
Drivers Driver Name Discreate Package Download Version
InBox Driver provided by Linux Distro install supported

Release: 18B
Firmware Firmware Name Version
BIOS/FW/UEFI Update for N2125 SAS/SATA Controller n2125-1.20.02-3
Drivers Driver Name Discreate Package Download Version
InBox Driver provided by Linux Distro install supported


Release 19A Change History Documents

BIOS/FW/UEFI Update for N2125 SAS/SATA Controller



BIOS/FW/UEFI Update for N2125 SAS/SATA Controller

Controller Supported:  IBM N2125 SAS/SATA Controller (46C9011)

NOTE TO SERVICE - Reference RETAIN #N/A

Version 1.20.02-4 - Moderate Impact/Low Probability of Occurrence
---------------
Contains:
  BIOS          Firmware         UEFI Driver
  07.39.00.00   20.00.02.00      07.27.04.00
fix:use pkgsdk4.16,it support os(sles15,windows 2019)

Version 1.20.02 - Moderate Impact/Low Probability of Occurrence
---------------
Contains:
  BIOS          Firmware         UEFI Driver
  07.39.00.00   20.00.02.00      07.27.04.00
  
Fixes:
- SUT hang when click start /locate for PD in UEFI or click SAS Topology in legacy option rom w/D3284 (Bug 122486)
  
Version 1.20.01 - Moderate Impact/Low Probability of Occurrence
---------------
Contains:
  BIOS          Firmware         UEFI Driver
  07.39.00.00   20.00.02.00      07.27.04.00

Enhancements:
- Added System X agentless support
- Indicate support for the ATA Device Server Password security protocol
- Allow UEFI and BIOS to be Enabled/Disabled individually
- Added ConnectorName and EnclosureLevel fields to SAS Device Page 0 to
  help identify physical location of a target device
- Set SATA HOLD threshold to be configurable in NVDATA
- If HW can gets into a stuck state, clear that state upon break received.

Fixes:
- Set SAS drives to track bad blocks using a bad block table rather than
  using a SCSI Write Long.
- Fixed DMAGroup performance issue.
- Fixed issue with Phase 18 IR FW boot a RAID volume (such as raid 10),
  2308 bootup hangs at OROM "Initializing.." and fault 8803 seen.
- Fixed report Luns command to a SATA drive fails with
  CheckCondition/Invalid Field in CDB when Allocation length set to Zero.
- Fixed issue where Raid Accelerator IOs can hang if the stream of IOs
  suddenly stops.
- Fixed issue where an invalid frame sent during a PIO-mode SATA
  passthrough command results in resetting the drive.
- Fixed issue where lots of NCQ I/O error messages were reported.
- Fixed issue where certain PCIe timeouts occur in the presence of link
  unavailable, and a hang condition or data corruption can occur.
- Fixed issue where system hangs after adapter reset with heavy IO load.
- Fixed issue where access to Last Logical Block Address (LBA) of SATA
  Drive is Prevented and LBA out Of range by one block is missed.
- Made change to deal with link getting stuck and causing missing drives.
- Fixed IR issue where page header information is not filled in when RAID
  PHYS DISK PAGE 0 is returned for a non-RAID Disk drive.
- Fixed issue where controller hits 0x265d fault while creating volume
  when there is an inactive volume.
- DID_SOFT_ERRORs are seen when hot plug is performed on the RAID1 volume
  along with IOs.
- Fixed issue where system gets hung and reboots while running IO's along
  with diag reset on the Controller which has active and inactive volumes.
- Fixed latency spikes seen during performance testing on OEM system
- MPI 2.5: distribute target command buffers received across multiple
  reply queues.
- Fixed issue where command sas2flash -dflash results in a non-functional
  system.
- Fixed issue where internal device reset storm after controller reset
  using long CDB.
- Fixed 0x6003 Fault Due to Task Management of Lost IO
- Fixed 0x58A1 fault occurs on partner controller while issuing MUR to a
  target mode controller with outstanding IOs.
- Fixed issue where IO error and stop when hot plug a HDD from RAID1
- Fixed issue where fault 8901 is seen once the volume is roamed.

Version 1.18.01 - Initial release
-------------
Contains:
  BIOS        Firmware    UEFI Driver
  7.35.01.00  18.00.00.00  7.25.04.01

Linux
 Enhancement:
 - Add support for RHEL 7





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

MegaRAID Storage Manager Application



MegaRAID Storage Manager Application

Supported controllers:
  - N2226 SAS/SATA HBA for Lenovo System x (00AE916)
  - N2225 SAS/SATA HBA for Lenovo System x (00AE912)	 
  - N2215 SAS/SATA HBA for Lenovo System x (47C8676)
  - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x
  - ServeRAID M1210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5225 SAS/SATA Controller for Lenovo System x (00AE938)
  - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x
  - N2125 SAS/SATA HBA for Lenovo System x
  - N2115 SAS/SATA HBA for Lenovo System x
  - Lenovo PureFlex System Storage Expansion Node
  - Onboard LSI 2004 SAS/SATA Controller
  - ServeRAID H1110 SAS/SATA Controller for Lenovo System x (81Y4492)
  - ServeRAID M5210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)
  - ServeRAID M5115 SAS/SATA Controller for Lenovo System x (90Y4390)
  - ServeRAID M1115 SAS/SATA Controller for Lenovo System X (81Y4448)


NOTE TO SERVICE - Reference RETAIN #N/A


17.05.01.03 - Moderate Impact/Low Probability of Occurrence
-----------
Enhancements:
- MSM: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564578) 


17.05.01.02	- Moderate Impact/Low Probability of Occurrence
-----------

17.05.01.00 - Moderate Impact/Low Probability of Occurrence (Suggested)
-----------

16.05.04.01 - Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Fixed an issue where MSM was not flashing 8MB FW file on M5200 series Controllers. (SCGCQ00996185)
 - Fixed an issue where Dashboard view and Main View for Create Virtual Drive option are inconsistent when all drives are configure as JBOD (SCGCQ01054496)
 - Fixed an issue where MSM was not able set secure JBOD (SCGCQ01064281)
 - Fixed an issue where MSM cannot flash M1115 or M1015 controller firmware. (SCGCQ01125515)
 - Fixed an issue where event Block Recovery is skipped due to dirty OCR and "Please reboot the system" not seen after dirty OCR." (SCGCQ00989881)
- Fixed an issue where MSM server profile shows repetitive headlines and inconsistent information for virtual drives (SCGCQ00996188)
- Fixed an issue where MSM hang is observed while DIFF PD is become shielded state and then unconfigured bad. (SCGCQ00553738)
 - Added generic error message when update iMR image on MR controller. (SCGCQ00934328)
 - Corrected inconsistency in Create SSCVD option across MSM tabs. (SCGCQ01013993) 
- Fixed an issue where virtual drive information header printed multiple times in the profile summary page. (SCGCQ01062382)
- Fixed an issue where background operations appear in profile summary without any table header. (SCGCQ01064081) 
- Fixed an issue where after IR controller firmware flash the popup for the update status is not displayed. (SCGCQ00916747)
 - Fixed an issue where MSM displayed an option to create Virtual drive even when there are no configurable disks present in RAID mode. (SCGCQ00945155)
- Fixed an issue where the Creating CacheCade SSD Caching menu option is not available. (SCGCQ01117219)
- Fixed an issue where connecting the expander to IR2 controller, drive ID info was not correctly displayed when the drive is inserted or deserted (SCGCQ01155781 Port of SCGCQ00898807)
 - Fixed an issue where title bar was missing, when trying to view the personality from SDS to Raid (SCGCQ00941885)
 - Fixed an issue where the create CCVD option was still seen after MAX (2TB) CCVD creation. (SCGCQ00952332)
 - Fixed an issue where the MSM showed wrong information about the DG in the summary page of RLM operation. (SCGCQ01039111)
 - Fixed an issue where MSM was not allowing to flash ctrlH on iMR controller. (SCGCQ01056002)
 - Fixed an issue where SWR for RHEL 6.8, driver version info was not aligned properly in MSM server profile. (SCGCQ01109158)
 - Fixed an issue where MSM showed inconsistent info for degraded spanned RAID Level DG's in Replace PD operation (SCGCQ01034766)
 -  Added code to disable CreateVD menu when recon is running in case of JBOD (SCGCQ00996752)
 - Fixed an issue where right clicking on the VD was not opening the change properties (SCGCQ00987893 Port of Defect - SCGCQ00952349
- Fixed an issue where leaving MegaRAID Storage Manager GUI open for an extended period of time (3 to 4 days), the GUI stopped automatically refreshing and monitor stopped updating AEN's. (SCGCQ01085197 Port of Defect - SCGCQ00946664)

Enhancements:
 - Added SLIR error codes and corresponding error messages handling to MSM. (SCGCQ00933586)
 - Added new operations at DG level to support MR_DCMD_LD_SET_TRASPORT_READY and MR_DCMD_LD_CLEAR_TRASPORT_READY (SCGCQ00920044)
 -  Do not allow VD creation on Removal Ready PD (SCGCQ01027492 Port ofSCGCQ00988701)


15.11.53.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:

 - No functional changes.


15.11.50.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:

 - Updated OpenSSL to address FREAK vulnerability (SCGCQ00877531)
 - Updated Java to address FREAK vulnerability (SCGCQ00877538)
 - Fixed an issue where no mnemonics/shortcut keys are available for Make Unconfigured Good and Manage Link Speed menu operations (SCGCQ00711990)
 - Fixed an issue where MegaRAID Storage Manager does not display logs after saving logs in a text file in VMware ESXi (SCGCQ00834428)
 - Fixed an issue where MegaRAID Storage Manager is showing "Sequence number is out of sync" warning message for "Secure using FDE" operation (SCGCQ00836494)
 - Fixed an issue where MegaRAID Storage Manager did not report the correct Windows operating system name/version (SCGCQ00854632)
 - Fixed an issue where the option to set critical and fatal events reports in the next reboot is not present (SCGCQ00866188)
 - Fixed an issue where Phy Count was being shown for Enclosure Physical Disks when it should not be (SCGCQ00869437)
 - Fixed an issue where a user is unable to View Server Profile (SCGCQ00873250)
 - Fixed an issue where BBU property displays "status = Unknown" when Supercap battery is in failed state (SCGCQ00887351)
 - Fixed an issue where there is no option to close the host view window (SCGCQ00897401)
 - Fixed an issue where MegaRAID Storage manager does not allow the option to uncheck the JBOD drive which has an operating system or file system on it (SCGCQ00897404)
 - Fixed an issue where Controller Info may not be displayed when CacheCade is enabled and the firmware supports 240 Virtual Drives (SCGCQ00898869)
 - Fixed an issue where the scroll bar in the Group Progress window may disappear when starting/suspending Consistency Check on multiple Virtual Drives  (SCGCQ00900408)
 - Fixed an issue where different information is shown in the "Create VD Summary Window" when creating in Simple Mode, and Capacity Alignment is not correct (SCGCQ00900416)
 - Fixed an issue where Virtual Drive numbering may be incorrect when creating more than three Virtual Drives (SCGCQ00902923)
 - Fixed an issue where Patrol Read may not be able to start on Partial-Size Virtual Drives (SCGCQ00918881)
 - Fixed an issue where Virtual Drives may not appear under the Logical tab after upgrading firmware and importing a configuration (SCGCQ00927688)
 - Fixed an issue where the wrong Operating System architecture may be displayed under Server Info (SCGCQ00928640)
 - Fixed an issue where "Create CacheCade VD" menu is displayed with max Logical Drives set, causing the operation to fail (SCGCQ00928753)
 - Fixed an issue where some windows may appear off-screen (SCGCQ00928758)
 - Fixed an issue where events are missing "Hidden" state of Virtual Drives (SCGCQ00933592)
 - Fixed an issue where Physical Drive information in Event Information is blank, but is correctly displayed in Backplane Properties (SCGCQ00933603)
 - Fixed an issue where destination drive is not listed under Logical View during a Copyback (SCGCQ00934374)
 - Fixed an issue where the Write Policy may not be correct after creating a Virtual Drive (SCGCQ00934377)
 - Fixed an issue where "Next Learn Cycle Time & Learn Period" may not be displayed when battery supports Transparent Learn (SCGCQ00934380)
 - Fixed an issue where "Online Firmware Update in progress" is showing after controller reset using storcli completes (SCGCQ00934505)
 - Fixed an issue where logs saved as Text file are missing Enclosure IDs in the events (SCGCQ00934595)
 - Fixed an issue where Operating System and Health fields are showing Unknown from the remote server Discovery page (SCGCQ00934721)
 - Fixed an issue where an application restart pop-up may occur while downgrading firmware, citing 240 Virtual Drive support (SCGCQ00939249)

Enhancements:

 - Enhanced the port enumeration naming scheme (SCGCQ00854619)
 - Added ability to select a range of events to parse when generating Alert Notifications (SCGCQ00854627)
 - Added ability to report controller flash device health status (SCGCQ00887610)
 - Changed Consistency Check / Patrol Read overlap message from Warning to Informational (SCGCQ00887611)
 - Added ability to handle MFI and SL error codes with corresponding error messages (SCGCQ00942678)


15.05.01.52 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Fixed an issue where MSM may not report HDD temperature information for drives in slot 0 connected to SWRAID - (SCGCQ00895878, Port of SCGCQ00867490)
 - Fixed an issue where Japanese Language packs may cause email alerts to be garbled - (SCGCQ00890256)
 - Fixed an issue where MSM may have a garbled character instead of 'TM' by using UNICODE \u2122 instead of ASCII 0x99 - (SCGCQ00880993)
 - Fixed an issue where event ID 150 descriptions were not consistent between the alert strings and the event properties - (SCGCQ00881952)

Enhancements:
 - Provide more descriptive port enumeration based on width of the port (SCGCQ00895884, Port of SCGCQ00854619)


15.05.01.51 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes:
 - Corrected the output for the key MSG_ASSOCIATED_SSCDDELETE_TEXT1 value with corresponding unicode for @TM Symbol in resource files (SCGCQ00880993)
 - Corrected the inconsistency in description for Event ID 150 between alert Strings.xml and MR_Events.properties


15.03.01.00 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes: 
 - OpenSSL security fixes

14.11.01.05 -  High Impact/High Probability of Occurrence
-----------
Fixes:
- Incorporated MSM MegaRAID 6.6 stream
- Fixed an issue where "Remove JBOD" option may not warn client even if the drive has a filesystem (SCGCQ00704645)
- Updated the StorCLI within MSM to the latest (SCGCQ00707316)
- Fixed an issue where MSM may still provide option to create a VD even after max VDs have been created (SCGCQ00707466)
- Fixed an issue where Enclosure details may not be shown in ViewServerProfile (SCGCQ00709507)
- Fixed an issue where "Select All" and "Start" buttons are enabled in Consistency Check window curing CC on only one VD (SCGCQ00740485)
- Fixed some null pointer dereferences in MSM EventXMLFormation (SCGCQ00757780)
- Fixed an issue where MSM may allow a CacheCade VD to be recreated with Always Write Back option (SCGCQ00759986)
- Fixed an issue where the message for Dedicated Hot Spare is missing the VD name (SCGCQ00770874)
- Fixed an issue where the Create Virtual Drive icon is still active when it shouldn't be (SCGCQ00772351)
- Fixed an issue where MSM popup showing Patrol Read progress even after setting Max Concurrent PDs for Patrol Read to 0 (SCGCQ00774583)
- Fixed an issue where "Initialization Aborted" message does not show up in MSM  (SCGCQ00706130)
- Fixed an issue where a Bootable JBOD with the OS on it shows as eligible for conversion to Unconfigured Good (SCGCQ00742001)
- Fixed an issue where Null Pointer Exceptions were being thrown in the AdapterMenu (SCGCQ00757770)
- Removed unused CIMPlugin dependencies in CacheCacde and modify the folder structures for respective OSes (SCGCQ00757819)
- Fixed an issue where a user may be able to login twice in a point of time as Administrator Full Access (SCGCQ00760231)
- Fixed an issue where discovery may fail after MSM installation with 1024bit keys on RHEL (SCGCQ00787334)
- Fixed an issue where the Graphical view for Enclosures may not be correct (SCGCQ00717047)
- Fixed an issue where MSM cannot create any RAID level if the drives are selected one by one (SCGCQ00734568)
- Fixed an issue where the shortcut key for Manage Link Speed menu option is not present (SCGCQ00709792)
- Fixed an issue where MSM shows an incomplete window for Advanced Software Options when using shortcut key as opposed to regular menu option (SCGCQ00713213)
- Fixed an issue where the Select All button is enabled in the Initialize window when only one R6 VD is available with partially degraded mode (SCGCQ00759357)
- Fixed an issue where MSM may throw "Requested command cannot be completed because resources are already in use" or "Invalid array specified"when creating arrays in specific circumstances (SCGCQ00762640)
- Fixed an issue where MSM may report CacheCade VD has been deleted even though it is still being deleted by firmware (SCGCQ00777823)
- Fixed some null reference issues (SCGCQ00766100)
- Fixed an issue where volume creation fails in MSM if the controller has firmware that supports 240 VDs (SCGCQ00664507)
- Fixed an issue where Consistency check cannot be scheduled in 64-bit Linux managing an ESXi host (SCGCQ00757859)
- Fixed an issue where "Select All" and "Start" buttons are enabled in Initialization window during Init on only one VD (SCGCQ00727600)
- Fixed an issue where one is unable to create a second VD in MSM through Dashboard "Create Virtual Drive" link (SCGCQ00766971)
- Fixed an issue where cannot uninstall MSM via uninstaller.sh script in RHEL6.5 (SCGCQ00691368)
- Fixed an issue where MSM fails to save Host Configuration Settings (SCGCQ00691421)
- Fixed an issue where alert strings for events 502, 512, 513 and 514 may be wrong (SCGCQ00698294)
- Fixed an issue where there may be a fatal error when logging in via Server button on top and trying to refresh using the option button on top (SCGCQ00727445)
- Fixed an issue where updating MSM may fail in Windows (SCGCQ00727990)
- Fixed an issue where MSM may display an invalid field (Parity Size) for R00 (SCGCQ00687943)
- Fixed an issue where a SuperCap reported as Bad may still show as Optimal (SCGCQ00785419)
- Fixed an issue where "Prepare for Removal" on PD may not work on PD with pending operations (SCGCQ00784866)
- Fixed an issue where R6 option may be displayed during migration of a 31-drive R0 (SCGCQ00703809)
- Fixed an issue where event log shows "null" instead of correct VD where Snapshot schedule properties have changed (SCGCQ00795792)
- Fixed an issue where R1 option may be displayed during migration of a 7-drive R0 (SCGCQ00694232)
- Fixed an issue where MSM may not login to remote host in the favorite list (SCGCQ00692364)
- Fixed an issue where entering security key in MSM to unlock PD fails to import afterwards (SCGCQ00785420)
- Fixed an issue where MSM may scroll additional Sense Info constantly after refreshing screen for SATA (SCGCQ00789079)
- Fixed an issue where Consistency Check is grayed out after disabling through MSM and can't be reenabled through MSM (SCGCQ00795183)
- Fixed an issue where one is unable to stop the MSMFramework service (SCGCQ00756996)
- Fixed an issue where Create Virtual Drive option is lost in MSM (SCGCQ00822350)
- Fixed an issue where there may be many blank messages in the MSM logs on controllers with multiple VDs (SCGCQ00827667)
- Fixed an issue where timestamps are incorrect in TTY logs saved through MSM (SCGCQ00829187)
- Fixed an issue where after creating a spanned VD, MSM creates duplicate drive groups (SCGCQ00830891)
- Fixed an issue where "TIME = Not Available" message appears in text file of events saved through MSM (SCGCQ00832354)
- Fixed an issue where during install MSM may show erroneous "major upgrade" warnings and errors and asks for restart of the system (SCGCQ00817865)
- Fixed an issue where MSM may not import SED / FDE Foreign Config using previous security key (SCGCQ00823013)
- Fixed an issue where Patrol Read and Consistency Check schedule overlap errors were listed as Warnings instead of Informational (SCGCQ00821374)
- Fixed an issue where the MSM log may be flushed after host reboot (SCGCQ00800288)

Features/enhancements
- Added the ability to display PCI Domain information, instead of just PCI Bus and Device (SCGCQ00712488)
- Added latest Pegasus library v2.13 (SCGCQ00650093)
- Recompiled Pegasus libraries for Windows with the latest OpenSSL (SCGCQ00729736)
- Added support for 2048bit RSA keys (SCGCQ00696866)
- Added support for reporting drive temperatures for all SAS/SATA HDDs/SSDs (SCGCQ00650088)
- Added PFK support for SSHA (SCGCQ00707653)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00821360)


14.05.02.03 -  Moderate Impact/Low Probability of Occurrence (Suggested)
-----------
Fixes: 
 - MSM reports full version nubmer to Lenovo comparison tools.
 - Fixed an issue where MSM alert for event ID 81 and ID 114 do not give notification.
 - Fixed an issue where MSM could not uninstall via uninstaller.sh script in RHEL 6.5.
 - Fixed an issue where MSM is not showing the "Selected Firmware Version" during online firmware update.
 - Fixed an issue where server status doesn't changes accordingly with IR2 controller in MSM login page.
 - Fixed an issue where MSM login screen missing host and OS name.
 - Fixed an issue where menu items load configuration and scan configuration are highlighted when the controller is in safe mode.
 - Fixed an issue where inconsistent write policy during EVS creation in MSM.
 - Implement SuperCap deep dive action items in the firmware and applications
 - Fixed an issue where MSM simple create virtual disk dialog box disappears for ServeRAID H1110
 - Fixed an issue where virtual drive erase option is not found.
 - Fixed an issue where MSM is throwing error code 0 x 32.
 - Fixed an issue where starting patrol read throwing error '0x58' when virtual disk erase is running.
 - Fixed an issue where MSM not reporting events for changes that occurred to IR volumes during power off.
 - Fixed an issue where MSM displays unsupported SATA drives for replace operation for regular 512n drives - Single Node.
 - Fixed an issue where MSM displays invalid field name for disabling data protection.
 - Fixed an issue where 4K virtual disk size is wrong during import of 64 virtual disk s - Single Node.
 - Fixed an issue where MSM need to return error when destroy key on peer node with existing secure virtual disk.
 - Fixed an issue where the user cannot uninstall MSM without xterm installed under Linux.
 - Fixed an issue where MSM login screen missing the domain ID column at the most right.
 - Resolved OpenSSL vulnerabilities.

13.11.01.07  - Initial release
-----------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

SAS2IRCU (Command Line) Utility for Storage Management



SAS2IRCU (Command Line) Utility for Storage Management for Linux

Supported Controllers: 
 - N2125 SAS/SATA Controller (46C9011)
 - N2115 SAS/SATA Controller (46C8989)      
 - ServeRAID H1110 SAS/SATA Controller for IBM System x (81Y4492)
 - ServeRAID H1135 Controller for IBM Flex System and BladeCenter (90Y4750)
 - 6Gb SAS HBA (46M0907)
 - 6Gb SSD HBA (68Y7362)
 - Onboard LSI 2004 SAS
  
NOTE TO SERVICE - Reference RETAIN #N/A

Version 20.00.00.00
------------------
Enhancement: 
 - Added RHEL 7 support

Version 18.00.00.00
------------------
Enhancement:
 - Added SLES 11 SP3 support.
 - Add an optional parameter EnablePI to CREATE command. Default value is 
   non-PI volume irrespective of underlying drive type.
 - Added two new commands, SETOFFLINE and SETONLINE to pause and restart
   resyncing of the IR volume.
 - Added new commands ALTBOOTIR and ALTBOOTENCL and added code to show this
   information as part of "display" command.

Fixes:
 - Fixed an issue where SAS3 cards where listed as UNKNOWN in SAS2IRCU.
 - Fixed locate command wait time.
 - Fixed an issue where kernel panic occurs while issuing the status command
   using IRCU with one optimal enabled volume and one inactive missing volume.
 - Fixed an issue where locate command only works for the first RAID volume
   member.
 - Fixed an issue where primary and alternate boot drives are in the same
   enclosure boot information is displayed for only one drive.
 - Fixed an issue where IRCU allows primary and alternate boot device to exist
   in the same volume.
 - Fixed an issue where the SETOFFLINE command to either primary or secondary
   drive the command execution fails with the following error message ‘Volume
   is not in optimal state. Error executing command SETOFFLINE,’ when the
   volume is in resyncing state.

Version 15.00.00.00
------------------
Fixes:
 - Fixed an issue where Sas2ircu allows creation of a SATA hotspare for
   a failed SAS volume.
 - Fixed an issue where a segmentation fault is seen when a hotspare
   delete command is executed on a bare drive.
 - Fixed an issue where a hotspare command is issued without any volumes
   present, but no error message is displayed.
 - Fixed an issue where the  phys disk output for the display command shows all
   enclosures/expanders as "Drive Type : SAS HDD" rather than "Device Type
   : Enclosure device services."
 - Fixed an issue where a volume is present and the display command is
   issued on a EFI 2.3 platform, the volume info displays incorrect
   encl/slot values.
 - Fixed an issue where attempting to add a SATA SSD drive as hot spare to
   a SATA HDD 4K volume, sas2ircu displays unknown error.  The error
   message has been corrected to "HDD and SSD mismatch."
 - Fixed an issue where SAS Gen2 controllers are not detected by SAS2IRCU.

Version 10.00.00.00
------------------
Enhancements:
 - Add IBMFRU Option to SAS2IRCU
 - SAS2IRCU Does Not Locate Drive in IR Volume
 - Filter drives that FW reports with AccesStatus set to DEVICE_BLOCKED
 - Added FreeBSD OS support for x86/amd64 platform
 - Include GUID of each drive in sas2ircu display command
 - The CREATE command usage is modified to put additional information
   for size as "The size of the RAID volume in Mbytes or 'MAX' for the
   maximum size available. Size other than 'MAX' is not supported."
 - Include SAS Address in the sas2ircu display data
 - Added capability to the DELETE command by which, user can delete a
   specific volume by providing the Volume ID. 
 - Description for delete in usage modified reflecting how this option
   needs to be used.  Warning message before deleting modified to appear
   more appropriate (To delete single volume or entire RAID configuration).
 - Added new functionality where the Linux adapter discovery code
   determines if the FW running on the adapter is IR or IT
 - Added  a new command DELETEVOLUME to allow individual volume deletion
   and the DELETE command functionality retained as deleting all volumes
   only.
 - SAS2IRCU will read RAID Configuration Pages only if the Firmware
   running on the controller is IR FW. The changes are done in DISPLAY
   command for the same. (Linux only)
 - Implement changes to support SAS2IRCU build for VMware MN ESXi 5.0

Fixes:
 - Fixed issue where Sas2ircu fails to delete Inactive missing raid volume
 - Fixed issue where sas2ircu is not displaying volume of size properly
   when a volume of size between 2 TB to 3TB is created.
 - Fixed issue where Sas2ircu.efi is not displaying sata(sony -DVD-RW AW-G17Os)
   when connected to the controller
 - Fixed issue where a egmentation fault was seen while doing display
   using sas2ircu after removal of drives from RAID10 volume
 - Fixed issue where sas2ircu does not show multiple deactivated volumes.
 - Fixed issue where Sas2ircu delete successful after passing junk
   characters as parameter
 - Fixed issue where SAS2IRCU failed to display the correct SAS WWID of the
   drive. It looks like the lower half of the address is all zeros.
 - Fixed issue where sas2ircu unable to create volumes in enclosures numbered
   greater than 9.
 - Fixed issue where SATA drives removed from RAID0 Volume shown as Missing
   SAS HDDs
 - Updated SAS2IRCU SDRS and usage information in the source to reflect
   that the offset is a byte offset and not DWORD.
 - Fixed issue where incorrect error message is displayed when Bootencl
   command executed with incorrect parameters.  Error messages referred
   BOOTENCL command as the command as BOOTIR.
 - Fixed issue where after a Raid10/Raid1volume is created, the Volume size
   (in sectors) and Number of remaining sectors is shown as 0 in the sas2ircu
   status command.
 - Fixed issue where Memory Map related errors displayed when volume is created
   using SAS2IRCU


Version 4.00.00.00 - Initial release
------------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved