Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): System x3850 X6 / x3950 X6 (6241) |
Targeted Operating System: SLES12SP3 |
YUM Repository Build Date: 2019_04_23 |
Device: |
Emulex 8Gb FC Dual-port HBA |
![]() Device Product Guide |
Part Number: 42D0494 Feature Code: 3580 |
|||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x10DF PCIe Sub Device ID: 0xF100 |
Release History: |
Change History Documents |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-12 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-1-1.sles12sp3.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.63_k4.4.103_ 6.38-1.sles12sp3.x86_64.rpm | 11.4.329.63_k4.4.103_6.38 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.142.28_k4.4.73_ 5-1.sles12sp3.x86_64.rpm | 11.4.142.28_k4.4.73_5 |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-9 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-1-1.sles12sp3.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.40_k4.4.103_ 6.38-1.sles12sp3.x86_64.rpm | 11.4.329.40_k4.4.103_6.38 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.142.28_k4.4.73_ 5-1.sles12sp3.x86_64.rpm | 11.4.142.28_k4.4.73_5 |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1205/LPe1200x) Firmware Update for Linux - 2.10x6-11.40a13 - Release 18A | 18a-2.10x6-8 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-1-1.sles12sp3.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.33_k4.4.103_ 6.38-1.sles12sp3.x86_64.rpm | 11.4.329.33_k4.4.103_6.38 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.142.28_k4.4.73_ 5-1.sles12sp3.x86_64.rpm | 11.4.142.28_k4.4.73_5 |
Release 19A Change History Documents |
=============================================================================== Emulex 8Gb Fibre Channel Firmware Package =============================================================================== Firmware Version: 2.10x6 Boot Code Version: 11.40a13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES15 Support - RHEL7 Update 6 Support - SLES12 SP4 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 2.10x6 Boot Code Version: 11.40a13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 5 Support - RHEL6 Update 10 Support - SLES12 Update 3 Maintenance Update Kernel Support - VMware ESXi 6.7 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 2.03x14 Boot Code Version: 11.40a4 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 4 Support - SLES12 Update 3 Support - This firmware/boot BIOS is not supported on legacy IBM "Blue" servers - Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ Fibre Channel Adapter[4XC7A08220] - Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ Fibre Channel Adapter[4XC7A08221] Known Issues: - The new 8G FC models are supported with subset of Lenovo server platforms =============================================================================== Firmware Version: 2.03x14 Boot Code Version: 11.20a6 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - Windows 2016 Support - VMware ESXi 6.5 Support Known Issues: - Beginning with software release 11.2, Emulex LightPulse adapters and OneConnect adapters have independent software kits. The "Broadcom Software Kit Migration Guide" document provides special instructions and considerations for using the driver kits for LightPulse and OneConnect adapters. https://docs.broadcom.com/docs/12378907 - 11.20a6 boot BIOS is not Microsoft Signed so secure boot functionality will not function properly. 11.20a7 which is Microsoft Signed is available from Lenovo customer support =============================================================================== Firmware Version: 2.03x7 Boot Code Version: 7.00a2 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Changed the Target Scan mechanism. If no LUN is attached, menu will display not supported or not configured. - Change the LUN Scan logic. If Target has at least one good LUN, the code will consider it as a supported target and will skip the bad LUNs. - Improved direct attach/point-to-point target interoperability in x86 BIOS Incremental Interoperability: - None Known Issues: - Universal Boot code includes component versioning changes: 1) Universal image no longer includes FCode. 2) x86/UEFI boot modified from n.nnan format to n.n.n.n format. - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.03x7 Boot Code Version: 7.00a0 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Bumped FW revision from 2.02A1 to 2.03X7 to resolve a UXSPi issue (188579) - Changed the Target Scan mechanism. If no LUN is attached, menu will display "not supported" or "not configured". - Fixed a bug with changing default ALPA setting when using the up arrow caused an invalid entry to show up. Incremental Interoperability: - Ported UEFI code into EDK II - Add CLP support in x86 ROM - Add >4GB memory support: Saturn 3.x Known Issues: - Universal Boot code includes component versioning changes: 1) Iniversal image no longer includes FCode. 2) x86/UEFI boot modified from n.nnan format to n.n.n.n format. - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02a1 Boot Code Version: 5.30a8 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Disable support for OOO frame queuing by default. <> (168151) - BDE Usage Model 4 Not working for FCP READ and WRITE commands with Block Guard (174973) - Abort IREAD exchange if FCP data frame received w/RO=0 twice (162750) - Out-going traffic incorrectly blocked due to Concurrent Sequence even though we are not at max. (168796) - Receipt of an unmapped ABTS frame for an inactive exchange may result in MBX timeout/fw stall when running w/Blockguard (143355) - Fixed issue where OS needs a manual reboot if UEFI installation. (183548) Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02x13 Boot Code Version: 5.30a7 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02x11 Boot Code Version: 5.30a6 Supported On: System x Rack, BladeCenter and Flex Problems Fixed: - SAN boot stopped working after firmware/boot BIOS upgrade Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02x11 Boot Code Version: 5.30a3 Supported On: System x Rack, BladeCenter and Flex Problems Fixed: - None Incremental Interoperability: - Grantley based ITE Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02x11 Boot Code Version: 5.30a3 Supported On: System x Rack and BladeCenter Problems Fixed: - Roll boot code version number to avoid conflict with IBM UXSPi updates Incremental Interoperability: - Inventory support for the System x xHMC (Chassis Hardware Management Console) for IBM Rack FC HBAs - Grantley Rack Servers Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.02x11 Boot Code Version: 5.13x4 Supported On: IBM System x Rack, BladeCenter, and Flex Problems Fixed: - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console) Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159225) =============================================================================== Firmware Version: 2.01a11 Boot Code Version: 5.13a0 Supported On: IBM System x Rack Problems Fixed: - None Incremental Interoperability: - UEFI 2.3.1 Compatibility Known Issues: - None =============================================================================== Firmware Version: 2.01a11 Boot Code Version: 5.12a15 Supported On: IBM System x Rack, BladeCenter, and Flex) Problems Fixed: - System hang when attempting to enter BIOS screen on AMI BIOS based servers Incremental Interoperability: - SLES 11.3 on IBM System x and BladeCenter Known Issues: - None =============================================================================== Firmware Version: 2.01a11 Boot Code Version: 5.12a13 Supported On: IBM System x Rack and BladeCenter Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM (BOFM) - Emulex FC configuration utility is in the wrong F1 setup screen - IBM CIOv adapter connected to Brocade 8 Gig FC BladeCenter switch intermittently Links up at less than 8 Gig Incremental Interoperability: - None Known Issues: - None =============================================================================== Firmware Version: 2.01a9 Boot Code Version: 5.12a11 Supported On: IBM System x Rack and BladeCenter Incremental Interoperability: - None Problems Fixed: - SANboot problem in IBM BladeCenter Known Issues: - None =============================================================================== Firmware Version: 2.01a9 Boot Code Version: 5.12a10 Supported On: IBM System x Rack, BladeCenter, and Flex Incremental Interoperability: - UEFI 2.3.1 compatibility Problems Fixed: - Utility in adapter selection screen shows PCIe2.5Gb/s X 4 - Miscellaneous issues with boot BIOS - Emulex 8gb ciov Port2 does not accept BOFM Boot-order "both" - Rhel 6.2 UEFI San boot failed w/ Emulex 8Gb FC - Fix potential I2C bus contention Known Issues: - None =============================================================================== Firmware Version 2.01a3 Boot Code Version: 5.12a5 Supported On: IBM System x Rack and BladeCenter Incremental Interoperability: - Enhanced timeout notifications for processing abort failures. Problems Fixed: - All multi-abort I/Os are returned on the same ring from which the ABORT_MXRI command was received. - Changed the TRCV response in the abort state to CMD RJT to enable the TRSP to be processed. - Corrected an issue with blocked TSEND operations. - Corrected a buffer leak issue with RRQ exchanges. - Corrected an issue where the TRCV IOCB was de-queued improperly causing a XFR_RDY flood. - Corrected an issue where the OXID field was not loaded in the XRI_ABORTED IOCB. - Corrected an issue in recognizing whether an EEPROM is present. Known Issues: - None =============================================================================== Firmware Version 2.00a4 Boot Code Version: 5.12a5 Supported On: IBM System x Rack and BladeCenter - Initial Release ===============================================================================
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2019 Lenovo. All rights reserved |
=============================================================================== Emulex FC Device Driver for Linux =============================================================================== Device Driver Version: 11.4.329.63 Supported On: Lenovo System x Rack and Flex Problems Fixed: - LPe16002 directly connected to NetApp E-Series Storage fails to reestablish paths after port bounce (219447) Incremental Interoperability: - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.329.43 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES15 Support - Drivers compiled with Retpoline enabled kernels - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.329.33 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 5 Support - SLES12 Update 3 Maintenance Update Kernel Support - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.168.11 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 4 Support - SLES12 Update 3 Support - NVMe over Fibre Channel Fabric Production Support - This driver is not supported on legacy IBM "Blue" servers - Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ Fibre Channel Adapter[4XC7A08220] - Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ Fibre Channel Adapter[4XC7A08221] Known Issues: - None =============================================================================== Device Driver Version: 11.2.209.25 Supported On: Lenovo System x Rack and Flex Problems Fixed: - LUN connection sometimes drops when ExpressLane is enabled Incremental Interoperability: - RHEL6 Update 9 Support - Lenovo Flex platforms (Machine Types: 7X15,7X16,7X17) - Lenovo Rack platforms (Machine Types: 7X01,7X02,7X03,7X04,7X05,7X06,7X07, 7X08,7X09,7X10,7X18,7X19,7X20,7X21,7X22) - Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter[7ZT7A00517] - Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter[7ZT7A00519] - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter-Option: 7ZT7A00521 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter-Option: 7ZT7A00522 Known Issues: - None =============================================================================== Device Driver Version: 11.2.209.7 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Link speed is now consistent across applications and boot Incremental Interoperability: - RHEL7 Update 3 Support - SLES12 SP2 Support - NVMe over Fibre Channel enablement Known Issues: - Beginning with software release 11.2, Emulex LightPulse adapters and OneConnect adapters have independent software kits. The "Broadcom Software Kit Migration Guide" document provides special instructions and considerations for using the driver kits for LightPulse and OneConnect adapters. https://docs.broadcom.com/docs/12378907 =============================================================================== Device Driver Version: 11.1.152.22 Supported On: Lenovo System x Rack and Flex Problems Fixed: - FCoE instability/lost link problems on NX548 switch failover tests (182149) Incremental Interoperability: - FC SRIOV with LPe31000 and LPe32000 Known Issues: - None =============================================================================== Device Driver Version: 11.0.240.0 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - Support for Gen 6 Fibre Channel HBAs - Improved logging and debug capabilities Known Issues: - None =============================================================================== Device Driver Version: 10.6.228.31 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES 12.1 - RHEL 7.2 Known Issues: - None =============================================================================== Device Driver Version: 10.6.205.0 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Incremental Interoperability: - Known Issues: - None =============================================================================== Device Driver Version: 10.4.299.0 Supported On: System x Rack Problems Fixed: - LPe16000 driver crash during performance testing Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products Known Issues: - None =============================================================================== Device Driver Version: 10.3.135.0 Supported On: Flex Problems Fixed: - Error recovery of a "hung" IO to a device is cancelling ALL IOs, not just the culprit one only - A NULL pointer dereference kernel panic occurs in lpfc_target_reset_handler() Incremental Interoperability: - SLES 12 - RHEL 6.6, 7.1 - Lenovo branded versions of formerly IBM branded products Known Issues: - None =============================================================================== Device Driver Version: 10.3.71.0 Supported On: Flex Problems Fixed: - Error recovery of a "hung" IO to a device is cancelling ALL IOs, not just the culprit one only Incremental Interoperability: - Grantley based ITE Known Issues: - None =============================================================================== Device Driver Version: 10.2.375.0 Supported On: IBM System x and BladeCenter Problems Fixed: - ELS txcmplq list corruption cause crash during error injection - Cleaned up several issues around ExpressLane feature - Need a HAL workaround for upgrading 10.0 XE102/XE104 f/w to 10.2 - I/O hang on RHEL6.5 for small block (4K) random i/o on POWER8 Incremental Interoperability: - Grantley Rack Servers Known Issues: - None =============================================================================== Device Driver Version: 10.2.261.0 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - lpfc message number 0127 is not reporting the correct information - Replace CRC16 used in T10-PI related driver code Incremental Interoperability: - Crosslink & Express Lane on LPe16k based solutions Known Issues: - None =============================================================================== Device Driver Version: 10.0.800.0 Supported On: IBM System x Problems Fixed: - Low bi-di throughput seen on 1g ports of HS-23 LOM - Multiple performance improvements - Bonding driver takes approx 20 seconds to be ready Incremental Interoperability: - RHEL 5.10 - RHEL 6.5 - XE-102 and XE-104 ASIC (OCx14xxx) - Support for set and get channels ethtool operation Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.4 and above 64-bit with KVM * SLES11 SP3 and above 64-bit with KVM NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest. =============================================================================== Device Driver Version: 8.3.7.27 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Execution of internal loopback causes a crash - Issue which can cause multipath failover to not work properly Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x and BladeCenter Known Issues: - None =============================================================================== Device Driver Version: 8.3.7.18 Supported On: IBM System x and BladeCenter Problems Fixed: - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - OXID Reused before RA_TOV without RRQ to recover - Intermittently storage paths will not recover after switch reboot Incremental Interoperability: - RHEL 5.9 - RHEL 6.4 Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.6.4 Supported On: IBM Flex Problems Fixed: - Fixed debug helper routine failed to dump CQ and EQ entries in non-MSI-X mode - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - Fixed boot from san failure when SLI4 FC device presented on the same PCI bus - Fix ABTS recovery to be FC spec compliant - Fixed not reporting logical link speed to SCSI midlayer when QoS not enabled - Fix performance problem in pt2pt mode - Fixed SCSI host create showing wrong link speed on SLI3 HBA ports - Update text for misconfigured port messages - Fix discovery bug when swapping cables Interoperability since previous release: - RHEL6.3 GA Kernel Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.5.86 Supported On: IBM System x and BladeCenter Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service Interoperability since previous release: - RHEL6.3 GA Kernel Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.5.74.1p Supported On: IBM System x and BladeCenter Problems Fixed: - Fixed kernel panic after scsi_eh escalation by checking the proper return status =============================================================================== Device Driver Version: 8.3.5.74 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix compilation errors on some kernels due to debugfs variable definitions - Used PCI configure space read to flush PCI function reset register write - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset =============================================================================== Device Driver Version: 8.3.5.66 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fixed port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix KERNEL allocation while lock held - Incorrect usage of bghm for BlockGuard errors - Fix warning on i386 system - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Support character device to take a reference on the driver - Fix for FDISC failures after firmware reset or link bounce - Support debugfs for injecting T10 DIF errors - Fix SLI4 BlockGuard behavior when protection data is generated by HBA - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Support more driver logs in area of SLI4 port error attention and reset recovery - Fix bug with driver returning the wrong ndlp - Sync up with actual upstream lpfc driver code - Support SLI4 16Gb FC Adapter support for T10 DIF / BlockGuard - Merge from upstream: scsi: Fix up files implicitly depending on module.h inclusion - Fix driver behavior when receiving an ADISC - Fixed unbounded firmware revision string from port caused the system panic - Fix bug with driver processing dump command type 4 using 16Gb FC Adapter - Fix driver does not reset port when reset is needed during fw_dump - Fix ELS FDISC failing with local reject / invalid RPI - Changed SLI4 FC port internal loopback from outer serdes to inner internal - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix bug with driver processing an els command using 16Gb FC Adapter - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtained link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed SLI4 16Gbit FC port internal and external diagnostic loopback tests - Fixed system panic during EEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing shost lock protection on setting/clearing bit in vport->fc_flag - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed illegal state transition during driver unload - Fixed system crash on SLI4 FC port looopback diagnostic test with large buffers - Fixed a potential error path that might try to free DMA memory not allocated - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix memory leak when running hba resets to SLI-4 board - Fix driver message 3092 and 3116 to KERN_WARNING - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Support loop for sli4 fc pass-through - No longer read fcoe parameters if board is not fcoe - Fix bug with driver passing a wrong count value - Support restore state and error log when sysfs board_mode attribute access failed - Fixed a typo in two of the log messages just introduced - Support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS. Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Return an error if the mbox sysfs is called - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when ASIC fails to initialize - Fix virtual fabrics bit set in FLOGI incorrectly - Fix bug with driver not returning extended mailbox data - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Modify WQ handling to use entry_repost - Moved link type definitions to apply to all driver streams - Support a sysfs attribute "protocol" to report SLI4 port link protocol type - Support SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Support structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fixed a warning when converting from simple_strtoul to strict_strtoul - Support Initial code to inject T10 DIF errors - Fixed a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Fixed null pointer dereference after clearing FCP policy rules - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Support check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fix sysfs lists fabric name for port that has been disconnected from fabric - Support FCP policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed fcp underrun reporting - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Support proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Fix compiler warning due to uninitialized local variable - Fix bus reset handler fails with bad failure code - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed sysfs API mismatch for building against SLES11 SP2 beta kernel - Fixed scsi midlayer queuecommand API mismatch for SLES11 SP2 beta kernel - Fixed ctlreg write bug not checking key string and limiting bytes to write - Fix default adapter name for the OCe15100 - Fixed incomplete scsi messages displayed - Fix cable pull failure on interface type 2 SLI-4 adapters - Fix enable_bg config parameter for SLI4 - Fixed not able to perform firmware reset through sysfs board_mode attribute - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix request firmware support for little endian systems - Fix driver firmware to match new firmware image format - Fixed SLI4 device firmware reset with SR-IOV virtual functions - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed handling of CVL for vports - Fixed crash when aborting els IOs - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Support fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - Fix issue where the FC/FCoE Async Receive CQE did not scale for 16G FC adapters - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Removed unused argument passed to the lpfc_bsg_diag_mode_enter routine - Fixed new ASIC device-mgmt BSG pass-through failed multi-buffer fw download - Support sysfs logging when writeable parameters are changed - Used PCI config space capability for sysfs get PF supported SR-IOV number of VFs - Support wait for SLI port status register for readyness following firmware reset - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - Consolidated duplicating macro definitions - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Modified log messages for T10-PI processing - iDiag fixed mailbox capture and dump overlapping bitmap macro definition =============================================================================== Device Driver Version: 8.3.5.35 Supported On: IBM System x and BladeCenter - Initial Release ===============================================================================
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2019 Lenovo. All rights reserved |