Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): System x3750 M4 (8753) |
Targeted Operating System: SLES15SP0 |
YUM Repository Build Date: 2019_11_21 |
Device: |
Emulex 16Gb FC Dual-port HBA |
![]() Device Product Guide |
Part Number: 81Y1662 Feature Code: A2W5 |
|||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x10DF PCIe Sub Device ID: 0xE204 |
Release History: |
Change History Documents |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 12.2.349.8 - Release 19A | 19a-lp16-12.2.349.8-2 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-12.2.349.9_k4.12.14_ 23-1.sles15sp0.x86_64.rpm | 12.2.349.9_k4.12.14_23 | |
elx-lpfc-kmp-default-debuginfo enablement code |
elx-lpfc-kmp-default-debuginfo-12.2.349.9_k4.12.14_ 23-1.sles15sp0.x86_64.rpm | 12.2.349.9_k4.12.14_23 |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.55 - Release 18A | 18a-lp16-11.4.329.55-10 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-default- 1-1.sles15sp0.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.63_k4.12.14_ 23-1.sles15sp0.x86_64.rpm | 11.4.329.63_k4.12.14_23 |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.55 - Release 18A | 18a-lp16-11.4.329.55-10 | ||
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.13 - Release 18A | 18a-lp16-11.4.329.13-7 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-default- 1-1.sles15sp0.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.63_k4.12.14_ 23-1.sles15sp0.x86_64.rpm | 11.4.329.63_k4.12.14_23 | |
elx-lpfc-vector-map enablement code |
elx-vector-map-default- 1-1.sles15sp0.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.43_k4.12.14_ 23-1.sles15sp0.x86_64.rpm | 11.4.329.43_k4.12.14_23 |
Release Async Change History Documents |
======================================================================== Emulex 16GB Gen5 Fibre Channel Firmware Package ======================================================================== This update package is applicable to the following HBA models: 95Y2386 - IBM Flex System FC5052 2-port 16Gb FC Adapter - PCI SSDID: E202 95Y2391 - IBM Flex System FC5054 4-port 16Gb FC Adapter - PCI SSDID: E282 81Y1655 - Emulex 16Gb FC Single-port HBA for IBM System x - PCI SSDID: E203 81Y1662 - Emulex 16Gb FC Dual-port HBA for IBM System x - PCI SSDID: E204 7ZT7A00521 - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter - PCI SSDID: E288 7ZT7A00522 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter - PCI SSDID: E289 For installation instructions, see the Install Tip file which is provided in the downloaded software package. NOTE: This document is designed to be cumulative. The current version is appended to the previous version(s). ========================================================================== Severity Definitions: Critical: Unable to use the solution resulting in a critical impact to operations. Includes high severity vulnerabilities. Suggested: The solution can be used with some functional restrictions resulting in minimal impact to business. Includes medium and low severity vulnerabilities. Initial: Initial release of the solution. ========================================================================== ========================================================================== Version 12.2.349.8, Build ID [19A], Severity [Critical] Release Date [ June 03,2019 ] ========================================================================== -------------------------------------------------------------------------- 1.0 Overview -------------------------------------------------------------------------- OS Versions supported o Red Hat Enterprise Linux Server 7 Update 6 o Red Hat Enterprise Linux Server 8 o SuSE Linux Enterprise Server 12 SP4 o SuSE Linux Enterprise Server 15 o SuSE Linux Enterprise Server 15 SP1 o VMware ESXi 6.5 Updateo VMware ESXi 6.7 Update o Windows 2016 o Windows 2019 Supported configurations can be found on the Lenovo Operating System Interoperability Guide at the following website: https://lenovopress.com/osig -------------------------------------------------------------------------- 2.0 Prerequisites and dependencies -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 3.0 Security Fixes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 4.0 Other Fixes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 5.0 Enhancements -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 6.0 Other Changes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 7.0 Limitations -------------------------------------------------------------------------- none =============================================================================== Firmware Version: 11.4.329.55 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Intermittent issue with NetApp where host port does not discover the SANboot LUN and the host port on the switch appears to get stuck as G-port (219985) Incremental Interoperability: - RHEL7 Update 6 Support - SLES12 SP4 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.329.13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES15 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.329.13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 5 Support - RHEL6 Update 10 Support - SLES12 Update 3 Maintenance Update Kernel Support - VMware ESXi 6.7 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.168.11 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 4 Support - SLES12 Update 3 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.2.209.29 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Addressed several cosmetic issues with xClarity Administrator Incremental Interoperability: - RHEL6 Update 9 Support - Lenovo Flex platforms (Machine Types: 7X15,7X16,7X17) - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter-Option: 7ZT7A00521 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter-Option: 7ZT7A00522 Known Issues: - None =============================================================================== Firmware Version: 11.2.209.19 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Link speed is now consistent across applications and boot - Stability issues addressed for XClarity firmware download Incremental Interoperability: - Windows 2016 Support - VMware ESXi 6.5 Support Known Issues: - Beginning with software release 11.2, Emulex LightPulse adapters and OneConnect adapters have independent software kits. The "Broadcom Software Kit Migration Guide" document provides special instructions and considerations for using the driver kits for LightPulse and OneConnect adapters. https://docs.broadcom.com/docs/12378907 =============================================================================== Firmware Version: 11.1.152.21 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Performance enhancement (191080) - UEFI FC BIOS showing wrong target name under Discovered Targets list(188383) - UEFI HII menu does not force reboot on changing the boot parameters (188721) - OneCLI tool settings not proliferating to BIOS Setup Menu (190894) - Improved direct attach/point-to-point target interoperability in x86 BIOS Incremental Interoperability: - None Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 11.0.270.24 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Auto Speed Negotiation not Always Negotiating to Highest Speed (154590) Incremental Interoperability: - Greater than 254 FC vport can now be created under Windows 2012R2 and Windows 2008 R2 (173657) - Avago branded transceivers no longer throw errors when plugged to Emulex HBAs (186049) - Generate SFP event notifications for presence detection and removal/insertion conditions (158278) Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.6.228.36 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Implemented warning threshold in PLDM temp PDR of LP16 FC adapter (185825) - Link went down after performing port bounce/link toggle in OS (184348) Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.6.228.14 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS - xClarity firmware download on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.4.303.3 Supported On: System x Rack Problems Fixed: - VF speed is showing wrongly in ethtool and Ocm. - Firmware download using ethtool -f command is failing with opcode 172-1 failed:status 100-208 - Can not set the DelayDeviceDiscovery to Max (255) by ASU tool - Ports intermittently logging in to Brocade switch as G-Port Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.3.137.0 Supported On: Flex Problems Fixed: - Blue screen after firmware flash to with virtualized WWPN Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.3.83.7 Supported On: Flex Problems Fixed: - None Incremental Interoperability: - Grantley based ITE Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.2.377.18 Supported On: System x Problems Fixed: - Link does not recover during IO + Port Cycling with FW 1.1.43.3 - BIOS versions return multiple values - LPe16k point to point (direct attached) connection not bootable in legacy BIOS - LPe16k point to point (direct attached) connection performance issues in legacy BIOS Incremental Interoperability: - Grantley Rack Servers Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change - Reported firwmare version in CMM is intermittently incorrect - Unable to set pause Flow control when connected to DCBX switch with PFC off - during cable pull testing a 40 second delay in link up experienced with Brocade switch ports - I/O completion and abort completion WQE are generated out of order - Unexpected WCQE in RQ CQ seen in RXRI mode while performing cable pulls Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console) - Crosslink & Express Lane on LPe16k based solutions Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.0.803.8 Supported On: IBM System x Problems Fixed: - EFI BOOT fail during SLES11 SP3 rolling reboot Incremental Interoperability: - None Known Issues: - None =============================================================================== Firmware Version: 1.1.43.21 Supported On: IBM System x Incremental Interoperability: - None Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu Known Issues: - None =============================================================================== Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup Known Issues: - None =============================================================================== Firmware Version: 1.1.43.3 Supported On: IBM System x Incremental Interoperability: - VPD-W for Lancer Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM Known Issues: - None =============================================================================== Firmware Version: 1.1.21.9 Supported On: IBM System x Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches Known Issues: - None =============================================================================== Firmware Version: 1.0.11.108 Supported On: IBM System x - Initial Release ===============================================================================
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2019 Lenovo. All rights reserved |
=============================================================================== Emulex FC Device Driver for Linux =============================================================================== Device Driver Version: 12.2.349.9 Supported On: Lenovo ThinkSystem Rack and Flex Problems Fixed: - Improved NVMe over FC Performance Incremental Interoperability: - RHEL8 Support - SLES12 SP4 Support - SLES15 SP1 Support - ThinkSystem Emulex LPe35000 32Gb 1-Port PCIe "FC" Adapter [4XC7A08250] - ThinkSystem Emulex LPe35002 32Gb 2-Port PCIe "FC" Adapter [4XC7A08251] Known Issues: - None =============================================================================== Device Driver Version: 11.4.329.65 Supported On: Lenovo System x Rack and Flex Problems Fixed: - LPe16002 directly connected to NetApp E-Series Storage fails to reestablish paths after port bounce (219447) Incremental Interoperability: - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.329.43 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES15 Support - Drivers compiled with Retpoline enabled kernels - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.329.33 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 5 Support - SLES12 Update 3 Maintenance Update Kernel Support - This driver is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Device Driver Version: 11.4.168.11 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 4 Support - SLES12 Update 3 Support - NVMe over Fibre Channel Fabric Production Support - This driver is not supported on legacy IBM "Blue" servers - Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ Fibre Channel Adapter[4XC7A08220] - Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ Fibre Channel Adapter[4XC7A08221] Known Issues: - None =============================================================================== Device Driver Version: 11.2.209.25 Supported On: Lenovo System x Rack and Flex Problems Fixed: - LUN connection sometimes drops when ExpressLane is enabled Incremental Interoperability: - RHEL6 Update 9 Support - Lenovo Flex platforms (Machine Types: 7X15,7X16,7X17) - Lenovo Rack platforms (Machine Types: 7X01,7X02,7X03,7X04,7X05,7X06,7X07, 7X08,7X09,7X10,7X18,7X19,7X20,7X21,7X22) - Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter[7ZT7A00517] - Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter[7ZT7A00519] - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter-Option: 7ZT7A00521 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter-Option: 7ZT7A00522 Known Issues: - None =============================================================================== Device Driver Version: 11.2.209.7 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Link speed is now consistent across applications and boot Incremental Interoperability: - RHEL7 Update 3 Support - SLES12 SP2 Support - NVMe over Fibre Channel enablement Known Issues: - Beginning with software release 11.2, Emulex LightPulse adapters and OneConnect adapters have independent software kits. The "Broadcom Software Kit Migration Guide" document provides special instructions and considerations for using the driver kits for LightPulse and OneConnect adapters. https://docs.broadcom.com/docs/12378907 =============================================================================== Device Driver Version: 11.1.152.22 Supported On: Lenovo System x Rack and Flex Problems Fixed: - FCoE instability/lost link problems on NX548 switch failover tests (182149) Incremental Interoperability: - FC SRIOV with LPe31000 and LPe32000 Known Issues: - None =============================================================================== Device Driver Version: 11.0.240.0 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - Support for Gen 6 Fibre Channel HBAs - Improved logging and debug capabilities Known Issues: - None =============================================================================== Device Driver Version: 10.6.228.31 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES 12.1 - RHEL 7.2 Known Issues: - None =============================================================================== Device Driver Version: 10.6.205.0 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Incremental Interoperability: - Known Issues: - None =============================================================================== Device Driver Version: 10.4.299.0 Supported On: System x Rack Problems Fixed: - LPe16000 driver crash during performance testing Incremental Interoperability: - Lenovo branded versions of formerly IBM branded products Known Issues: - None =============================================================================== Device Driver Version: 10.3.135.0 Supported On: Flex Problems Fixed: - Error recovery of a "hung" IO to a device is cancelling ALL IOs, not just the culprit one only - A NULL pointer dereference kernel panic occurs in lpfc_target_reset_handler() Incremental Interoperability: - SLES 12 - RHEL 6.6, 7.1 - Lenovo branded versions of formerly IBM branded products Known Issues: - None =============================================================================== Device Driver Version: 10.3.71.0 Supported On: Flex Problems Fixed: - Error recovery of a "hung" IO to a device is cancelling ALL IOs, not just the culprit one only Incremental Interoperability: - Grantley based ITE Known Issues: - None =============================================================================== Device Driver Version: 10.2.375.0 Supported On: IBM System x and BladeCenter Problems Fixed: - ELS txcmplq list corruption cause crash during error injection - Cleaned up several issues around ExpressLane feature - Need a HAL workaround for upgrading 10.0 XE102/XE104 f/w to 10.2 - I/O hang on RHEL6.5 for small block (4K) random i/o on POWER8 Incremental Interoperability: - Grantley Rack Servers Known Issues: - None =============================================================================== Device Driver Version: 10.2.261.0 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - lpfc message number 0127 is not reporting the correct information - Replace CRC16 used in T10-PI related driver code Incremental Interoperability: - Crosslink & Express Lane on LPe16k based solutions Known Issues: - None =============================================================================== Device Driver Version: 10.0.800.0 Supported On: IBM System x Problems Fixed: - Low bi-di throughput seen on 1g ports of HS-23 LOM - Multiple performance improvements - Bonding driver takes approx 20 seconds to be ready Incremental Interoperability: - RHEL 5.10 - RHEL 6.5 - XE-102 and XE-104 ASIC (OCx14xxx) - Support for set and get channels ethtool operation Known Issues: - SR-IOV is supported with the following Linux distributions: * RHEL 6.4 and above 64-bit with KVM * SLES11 SP3 and above 64-bit with KVM NOTE: Guest operating system support is dependent on the Emulex driver version installed in the guest. =============================================================================== Device Driver Version: 8.3.7.27 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Execution of internal loopback causes a crash - Issue which can cause multipath failover to not work properly Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x and BladeCenter Known Issues: - None =============================================================================== Device Driver Version: 8.3.7.18 Supported On: IBM System x and BladeCenter Problems Fixed: - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - OXID Reused before RA_TOV without RRQ to recover - Intermittently storage paths will not recover after switch reboot Incremental Interoperability: - RHEL 5.9 - RHEL 6.4 Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.6.4 Supported On: IBM Flex Problems Fixed: - Fixed debug helper routine failed to dump CQ and EQ entries in non-MSI-X mode - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - Fixed boot from san failure when SLI4 FC device presented on the same PCI bus - Fix ABTS recovery to be FC spec compliant - Fixed not reporting logical link speed to SCSI midlayer when QoS not enabled - Fix performance problem in pt2pt mode - Fixed SCSI host create showing wrong link speed on SLI3 HBA ports - Update text for misconfigured port messages - Fix discovery bug when swapping cables Interoperability since previous release: - RHEL6.3 GA Kernel Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.5.86 Supported On: IBM System x and BladeCenter Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service Interoperability since previous release: - RHEL6.3 GA Kernel Known Issues: - No known issues =============================================================================== Device Driver Version: 8.3.5.74.1p Supported On: IBM System x and BladeCenter Problems Fixed: - Fixed kernel panic after scsi_eh escalation by checking the proper return status =============================================================================== Device Driver Version: 8.3.5.74 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix compilation errors on some kernels due to debugfs variable definitions - Used PCI configure space read to flush PCI function reset register write - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset =============================================================================== Device Driver Version: 8.3.5.66 Supported On: IBM System x, BladeCenter, and Flex Problems Fixed: - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fixed port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix KERNEL allocation while lock held - Incorrect usage of bghm for BlockGuard errors - Fix warning on i386 system - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Support character device to take a reference on the driver - Fix for FDISC failures after firmware reset or link bounce - Support debugfs for injecting T10 DIF errors - Fix SLI4 BlockGuard behavior when protection data is generated by HBA - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Support more driver logs in area of SLI4 port error attention and reset recovery - Fix bug with driver returning the wrong ndlp - Sync up with actual upstream lpfc driver code - Support SLI4 16Gb FC Adapter support for T10 DIF / BlockGuard - Merge from upstream: scsi: Fix up files implicitly depending on module.h inclusion - Fix driver behavior when receiving an ADISC - Fixed unbounded firmware revision string from port caused the system panic - Fix bug with driver processing dump command type 4 using 16Gb FC Adapter - Fix driver does not reset port when reset is needed during fw_dump - Fix ELS FDISC failing with local reject / invalid RPI - Changed SLI4 FC port internal loopback from outer serdes to inner internal - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix bug with driver processing an els command using 16Gb FC Adapter - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtained link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed SLI4 16Gbit FC port internal and external diagnostic loopback tests - Fixed system panic during EEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing shost lock protection on setting/clearing bit in vport->fc_flag - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed illegal state transition during driver unload - Fixed system crash on SLI4 FC port looopback diagnostic test with large buffers - Fixed a potential error path that might try to free DMA memory not allocated - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix memory leak when running hba resets to SLI-4 board - Fix driver message 3092 and 3116 to KERN_WARNING - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Support loop for sli4 fc pass-through - No longer read fcoe parameters if board is not fcoe - Fix bug with driver passing a wrong count value - Support restore state and error log when sysfs board_mode attribute access failed - Fixed a typo in two of the log messages just introduced - Support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS. Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Return an error if the mbox sysfs is called - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when ASIC fails to initialize - Fix virtual fabrics bit set in FLOGI incorrectly - Fix bug with driver not returning extended mailbox data - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Modify WQ handling to use entry_repost - Moved link type definitions to apply to all driver streams - Support a sysfs attribute "protocol" to report SLI4 port link protocol type - Support SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Support structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fixed a warning when converting from simple_strtoul to strict_strtoul - Support Initial code to inject T10 DIF errors - Fixed a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Fixed null pointer dereference after clearing FCP policy rules - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Support check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fix sysfs lists fabric name for port that has been disconnected from fabric - Support FCP policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed fcp underrun reporting - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Support proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Fix compiler warning due to uninitialized local variable - Fix bus reset handler fails with bad failure code - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed sysfs API mismatch for building against SLES11 SP2 beta kernel - Fixed scsi midlayer queuecommand API mismatch for SLES11 SP2 beta kernel - Fixed ctlreg write bug not checking key string and limiting bytes to write - Fix default adapter name for the OCe15100 - Fixed incomplete scsi messages displayed - Fix cable pull failure on interface type 2 SLI-4 adapters - Fix enable_bg config parameter for SLI4 - Fixed not able to perform firmware reset through sysfs board_mode attribute - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix request firmware support for little endian systems - Fix driver firmware to match new firmware image format - Fixed SLI4 device firmware reset with SR-IOV virtual functions - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed handling of CVL for vports - Fixed crash when aborting els IOs - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Support fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - Fix issue where the FC/FCoE Async Receive CQE did not scale for 16G FC adapters - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Removed unused argument passed to the lpfc_bsg_diag_mode_enter routine - Fixed new ASIC device-mgmt BSG pass-through failed multi-buffer fw download - Support sysfs logging when writeable parameters are changed - Used PCI config space capability for sysfs get PF supported SR-IOV number of VFs - Support wait for SLI port status register for readyness following firmware reset - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - Consolidated duplicating macro definitions - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Modified log messages for T10-PI processing - iDiag fixed mailbox capture and dump overlapping bitmap macro definition =============================================================================== Device Driver Version: 8.3.5.35 Supported On: IBM System x and BladeCenter - Initial Release ===============================================================================
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2019 Lenovo. All rights reserved |