Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SR250 (7Y51, 7Y52, 7Y72, 7Y73, 7Y53)
Targeted Operating System: RHEL7.6
YUM Repository Build Date: 2019_11_17

YUM Repository Release Version: 19C

Device:
ThinkSystem 430-8e SAS/SATA 12Gb HBA

Device Product Guide

Part Number: 7Y37A01090
Feature Code: AUNM
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0202


Release History:
Release: 19C
Change History Documents
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-09.02.00.07
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-08.01.05.00-1
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-30.00.00.00_el7.6- 1.x86_64.rpm 30.00.00.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-28.00.03.00_el7.6- 1.x86_64.rpm 28.00.03.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-27.125.01.00_el7.6- 2.x86_64.rpm 27.125.01.00_el7.6
Utilities Utility Name Version
LSI Storage Authority Software for windows and linux (For Linux) 007.010.014.000
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
LSI Storage Authority Software for windows and linux 005.047.000.000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
LSI Storage Authority Software for windows and linux 004.189.000.000
StorCLI command line tool for anyos storcli-007.0713.0000.0000

Release: 19C
Change History Documents
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-09.02.00.07
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-08.01.05.00-1
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-30.00.00.00_el7.6- 1.x86_64.rpm 30.00.00.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-28.00.03.00_el7.6- 1.x86_64.rpm 28.00.03.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-27.125.01.00_el7.6- 2.x86_64.rpm 27.125.01.00_el7.6
Utilities Utility Name Version
LSI Storage Authority Software for windows and linux (For Linux) 007.010.014.000
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
LSI Storage Authority Software for windows and linux 005.047.000.000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
LSI Storage Authority Software for windows and linux 004.189.000.000
StorCLI command line tool for anyos storcli-007.0713.0000.0000

Release: 19C
Change History Documents
Firmware Firmware Name Version
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-09.02.00.07
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux) 430-3.03-06
BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA 430-08.01.05.00-1
Drivers Driver Name Discreate Package Download Version
mpt3sas
  kernel driver
kmod-mpt3sas-30.00.00.00_el7.6- 1.x86_64.rpm 30.00.00.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-28.00.03.00_el7.6- 1.x86_64.rpm 28.00.03.00_el7.6
mpt3sas
  kernel driver
kmod-mpt3sas-27.125.01.00_el7.6- 2.x86_64.rpm 27.125.01.00_el7.6
Utilities Utility Name Version
LSI Storage Authority Software for windows and linux (For Linux) 007.010.014.000
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
LSI Storage Authority Software for windows and linux 005.047.000.000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
LSI Storage Authority Software for windows and linux 004.189.000.000
StorCLI command line tool for anyos storcli-007.0713.0000.0000


Release 19C Change History Documents

BIOS and Firmware Update for ThinkSystem 430-x SAS/SATA 12Gb HBA (For Linux)



ThinkSystem 430-x SAS/SATA 12Gb HBA Firmware and BIOS Update

Supported Adapters:  
             ThinkSystem 430-8i SAS/SATA 12Gb HBA
		     ThinkSystem 430-16i SAS/SATA 12Gb HBA
		     ThinkSystem 430-8e SAS/SATA 12Gb HBA
		     ThinkSystem 430-16e SAS/SATA 12Gb HBA
             ThinkSystem 430-8i  SAS/SATA 12Gb Dense HBA

NOTE TO SERVICE - Reference RETAIN #N/A

Version 3.03-06
---------------
Contains:
    BIOS            Firmware      UEFI Driver
    9.05.00.00      3.125.11.00   03.01.00.00


Version 2.08 -  New Function Only/No fixes
---------------
Contains:
  BIOS         Firmware      UEFI Driver
  9.01.03.00   01.125.16.00  01.04.00.00





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

LSI HBA and HBA/LSI Onboard 12Gb SAS/SATA/SSD Driver for RHEL7 (For Rhel)



12Gb HBA SAS/SATA/SSD Driver for Linux

Supported Controllers: 
 - N2215 SAS/SATA HBA (47C8676)
 - N2225 SAS/SATA HBA (00AE912)
 - N2226 SAS/SATA HBA (00AE916)
 - ThinkSystem 430-8i SAS/SATA 12Gb HBA
 - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
 - ThinkSystem 430-16i SAS/SATA 12Gb HBA
 - ThinkSystem 430-8e SAS/SATA 12Gb HBA
 - ThinkSystem 430-16e SAS/SATA 12Gb HBA

Supported Kernesls:  7.6    
                     7.5    3.10.0-862 
                     7.4    3.10.0-693

					 
version	30.00.00.00-1 -- Moderate Impact/Low Probability of Occurrence
-----------------------
Linux driver-PH11

defects	
 - Uninstallation of mpt3sas rpm on Citrix6.0 fails with error message "No module mpt3sas found"(SCGCQ00342761) 
 - Device may not be properly offlined or unblocked in some scenarios.(SCGCQ00347498) 
 - Running processes are not getting resumed post hibernation(SCGCQ00395183) 
 - Driver does not load with Invader C0 with DDR enabled and Host Credits set to 30,000.(SCGCQ00395447) 
 - Setting a default value for max_msix_vectors(SCGCQ00448248) 
 - Linux mpt3sas: Installation of mpt3sas driver rpm fails on OEL7.1 OS(SCGCQ00846206) 
 - Linux mpt3sas: Fix wrong size of argument being passed, which is identified by Coverity tool(SCGCQ00881680) 
 - Linux Combined src: Observed compilation errors on RHEL5 and SLES10 kernels(SCGCQ00917411) 
 - Observing Protection fault due to sas device list corruption(SCGCQ00933587) 
 - System crashes while unloading and loading driver with NVMe drive attached(SCGCQ01098644) 
 - Block and unblock messages are not observed when NVMe drive is removed(SCGCQ01124682) 
 - FW Faulted with fault code 0x5861 while running IOs with NVMe Encapsulated Messages(SCGCQ01206566) 
 - Marlin B0: OS crashed while running Diag reset with IOs(SCGCQ01311474) 
 - Buildkit is modified to install Out of box rpm also in '/lib/modules/4.4.0+2/updates' and also RPM naming convention has been changed to match the inbox driver naming convention.(SCGCQ01318375) 
 - Disable ASPM for MPI2 controllers(SCGCQ01329184) 
 - RHEL 6.8 32 Bit is hitting kernel panic after loading Phase5.0 PA-3 Driver for IT Ventura Controller.(SCGCQ01418569) 
 - Update code to free intended memory pool.(SCGCQ01488145) 
 - Memory leak when unloading driver with NVMe flashed SAS35 controller in the system(SCGCQ01497725) 
 - Memory leak, after cable pull and push of SAS/SATA drives with DMD setSCGCQ01509274) 
 - When the volume members are hot removed and added while performing diag reset, the phy disks are not discovered.(SCGCQ00344824) 
 - The RHEL5, RHEL6 and SLES11 OS rpms in FIXID package do not comply to the naming standard(SCGCQ00477885) 
 - Kernel Panic seen while booting the system with blank card.(SCGCQ00574258) 
 - Driver initialization fails after some random iterations of load/unload of mpt3sas driver module(SCGCQ00589083) 
 - Mpt3sas driver initialization fails on Citrix XenServer(SCGCQ00676273) 
 - Linux mpt3sas SRIOV: SATA devices are not visible on the VMs when the base machine OS is RHEL5.x(SCGCQ00730461) 
 - SMP IRQ affinity per CPU is not added on few supported kernels(SCGCQ00731242) 
 - TRI_MODE definition should be removed from mpi header(SCGCQ00834585) 
 - Linux mpt3sas: Fix array compared against '0',which is identified by Coverity tool(SCGCQ00881517) 
 - Linux mpt3sas: Fix Resource leak identified by Coverity tool(SCGCQ00881682) 
 - Linux SAS3: Unable to boot into Fedora22 OS when connected the OS drive behind HBA after installing the driver rpm(SCGCQ00886999) 
 - Initial Ref Tag is incorrect with 4K sector size drives when PI is enabled for (>=3.18 kernels(SCGCQ01015654) 
 - Code Review Defect: The NVMe native PRP construction uses wrong address in couple of places and that needs to be fixed.(SCGCQ01079119) 
 - Linux Ventura IT phase2: Unable to achieve product targets performance numbers with SAS devices(SCGCQ01175998) 
 - Linux SAS35 mpt3sas: Driver load with less HBA queue size while doing multiple driver unload and load operations(SCGCQ01213150) 
 - Print message of driver for Active cable power management, prints incomplete for RHEL6.x(SCGCQ01255499) 
 - call-trace observed on RHEL6.x while unloading driver.(SCGCQ01336601) 
 - Ph4 IT Linux mpt3sas: Observing kernel panic during topology configuration w/ blk-mq enabled(SCGCQ01351060) 
 - Ventura Phase5: OS crash while removing the drives connected to the controller(SCGCQ01386942) 
 - Linux IT SAS3.5 Phase5 mpt3sas: Observing MCE errors while upgrading the Firmware(SCGCQ01440053) 
 - Workaround in driver to post 64bit request descriptor to register at offset 0xC0/0xC4 to avoid hitting HW bug(SCGCQ01514520) 
 - Fix, False timeout prints for ioctl and other internal commands during controller reset.(SCGCQ01555936) 
 - Linux IT Ph9 mpt3sas: Fix Unknown symbol __umoddi3 dependency error while loading the driver(SCGCQ01869644) 
 - Device is Offlined during Disable/Enable of Inter-Expander Phys(SCGCQ00323892) 
 - Linux mpt3sas: port enable is failed during mpt3sas driver loaded with module parameter max_msix_vectors set to 1(SCGCQ00485663) 
 - In certain cases when max_msix_vectors was to set to 8, it is printing -1(SCGCQ00500728) 
 - Synchronization between PF and VF host drivers is missing while performing diag reset operation(SCGCQ00682671) 
 - Port enable event timeout is observed on VF drivers(SCGCQ00711051) 
 - Linux mpt3sas: Kernel Panic while creating filesystem on a drive(SCGCQ00731042) 
 - SAS3.5 Phase 2 Linux Driver : IOs terminate with Ref Tag and Guard errors on NvMe drives .(SCGCQ01206759) 
 - Ensure the connector_name string is NUL-terminated for NVMe devices(SCGCQ01225123) 
 - Linux IT SAS35 Phase3: Firmware Fault 0x5862 seen after connecting drives to Cutlass A1 card(SCGCQ01273339) 
 - Code Review defect: Don't send sync cache and SSU to FW, when pci_error_recovery or adapter_over_temp is set(SCGCQ01341910) 
 - use scsi_internal_device_block_nowait for RHEL distros greater than RHEL7.3(SCGCQ01526190) 
 - Phase 9: Marking transport command as completed though the command is in use.(SCGCQ01829803) 
 - Phase9 Linux Driver:- Include RHEL 7.6 & SLES12SP4 binaries to "28.00.01.00-1"(SCGCQ02035467) 
 - RAID Volume drives have FPE disabled after a Diag Reset.(SCGCQ00330248) 
 - Driver initialization fails after some random iterations of driver load & unload(SCGCQ00551238) 
 - MPI specs mentions Slot field of SAS DVC pg0 is not valid when EnclosureHandle field is zero which is not taken care in code(SCGCQ00588226) 
 - INVALID_STATE ioc status is not handled properly on VFs for SAS IO UNIT Control message.(SCGCQ00701320) 
 - Linux mpt3sas SRIOV: IO''s terminated and 0x2667 fault is observed on VFs while performing diag reset on PF.(SCGCQ00718817) 
 - Linux mpt3sas SRIOV: kernel panic observed while running TMs from VFs(SCGCQ00729497) 
 - Linux mpt3sas: PFA LED was still glowing on Enclosure even when SMART error SATA drive is replaced with good SATA drive(SCGCQ00806442) 
 - Linux mpt3sas: Fix Unused pointer value defect identified by Coverity tool(SCGCQ00881681) 
 - Linux Driver: Sles 11 SP4 beta Driver rpm file names are in wrong format(SCGCQ00888840) 
 - Linux Driver: Partial driver message is displayed when active cable power consumption exception occurs(SCGCQ01025061) 
 - Coverity Linux_mpt3sas Ph2: Missing break in switch((SCGCQ01215510) 
 - Coverity Linux_mpt3sas Ph2: Nesting level does not match indentationSCGCQ01215516) 
 - Coverity Linux_mpt3sas Ph2: Wrong size of argument being passed as parameter to function	(SCGCQ01215534) 
 - Coverity Linux_mpt3sas Ph2: Logically dead code(SCGCQ01216306) 
 - NVMe devices are not visible to user on Big endian systems.(SCGCQ01249933) 
 - Unmap DMA mappings done while building PCIE native SGL(NVMe PRP(SCGCQ01254375) 
 - Linux IT mpt3sas: Fix the defects opened in CC reviews #13767 & #13774 related Dual Path topology support(SCGCQ01266371) 
 - mpt3sas: Avoid sleeping in interrupt context(SCGCQ01329329) 
 - Linux IT sas35 Phase5 mpt3sas: FW events sent before diagnostic reset are not getting cleaned up during reset(SCGCQ01397582) 
 - Ventura: As per MPI spec use Supplemental Reply Post Host Index Register(combined reply queue(SCGCQ01629402) 
 - Default value is not set for prot_capabilities when negative value is given for prot_mask parameter(SCGCQ00485251) 
 - Blocked Devices are made offlined if diag reset is issued at time of unblocking the device.(SCGCQ00493093) 
 - When device unblocked in certain cases, no messages are not seen in the logs regarding device unblock(SCGCQ00664470) 
 - When IOC goes bad, while flushing the IOs, protection info SGLs are not released for DIF IOs.(SCGCQ00664893) 
 - Linux mpt3sas SRIOV: SRIOV support is not enabled on Fedora OS kernels(SCGCQ00736946) 
 - Linux mpt3sas: XenServer 5.5 binaries are missing in the release tar ball(SCGCQ00802063) 
 - Linux mpt3sas: Fix dereference NULL return value defect identified by Coverity tool(SCGCQ00881498) 
 - Linux mpt3sas: Fix Uninitialized scalar variable defect identified by Coverity tool(SCGCQ00881684) 
 - Linux mpt3sas: CPU affinity hint is un-uniformly enabled in case if the number of CPUs are more than MSI-X vectors enabled(SCGCQ00903484) 
 - Asynchronous completion of timedout IO and task abort of timedout IO.(SCGCQ01027851) 
 - Coverity Linux_mpt3sas Ph2: Wrong size of argument being passed as parameter to function(SCGCQ01222482) 
 - Driver fails to load post installation.(SCGCQ01458946) 
 - Fix Timeout value and Reset method used for Target Reset issued on internal command Timeout. (Code Review fix)(SCGCQ01473759) 
 - Linux mpt3sas: System hang when a drive is removed from JBOD on sles11sp3 OS(SCGCQ00426108) 
 - Loading mpt3sas driver hangs on few kernels because of memory alloc failure.(SCGCQ00518874) 
 - End device location is not displayed few times when internal commands fail during device discovery.(SCGCQ00595788) 
 - Kernel panic while issuing LUN reset or target reset during running IOs(SCGCQ00655811) 
 - Remove extra lock being acquired and add RHEL 6.2+ support for host_lockless mode(SCGCQ00682882) 
 - Linux mpt3sas: Wrong description was displayed on the dpkg -l command output on Debian OS's(SCGCQ00828818) 
 - Linux mpt3sas: Fix unchecked return value defect identified by Coverity tool(SCGCQ00881685) 
 - As per MPI26 spec each reply queue set must have 16 reply queues with same upper 32bits of their memory address(SCGCQ01272382) 
 - Updated OEL6_UEK and OEL7_UEK buildkit(SCGCQ01436811) 
 - Controller fault state 265d while loading latest merged driver for SAS2 card(SCGCQ01471650) 
 - Remove logically dead code(SCGCQ01488142) 
 - OS crashes when drives are hot plugged while loading driver(SCGCQ01494556) 
 - Fix compilation error for SLES11(SCGCQ01698115) 
 - Driver compilation fails on latest upstream kernel(>= v4.17(SCGCQ01799543) 
 - Driver goes in infinite retry loop if internally generated REPORT LUN command response jammed with Check condition(SCGCQ00319620) 
 - Reply post queue depth calculation is not as per the MPI2.5 spec.(SCGCQ00322490) 
 - Infinite loops can occur if MPI2_IOCSTATUS_CONFIG_INVALID_PAGE is not returned(SCGCQ00347491) 
 - kernel panic during module load followed by Enclosure removal.(SCGCQ00384772) 
 - Updated SAS3 README.pdf(SCGCQ00434818) 
 - Kernel Panic is seen when issued Diag reset from task management(SCGCQ00654562) 
 - Set the module param allow_drive_spindown to default if invalid values are passed.(SCGCQ00711793) 
 - Linux mpt3sas: Driver rpm for OEL5.11 UEK kernel is not generated in the 7.255.04.00 alpha build.(SCGCQ00783341) 
 - Linux Ventura IT Phase2 : Observing Data Corruption which chaos tool on NVMe drives(SCGCQ01187754) 
 - Linux SAS35 Phase2: Allocate PCIe SGL pool only for SAS35 HBA devices(SCGCQ01204019) 
 - Linux SAS35 IT Ph2: SATA drive will be in blocked state if diag reset occurs while any ATA Passthrough command is outstanding▪(SCGCQ01221454) 
 - Upstream mpt3sas: fix hang on ata passthru commands(SCGCQ01255965)
 - Fixed - Sync cache command failure with hostbyte=DID_NO_CONNECT during driver unload.(SCGCQ01291425) 
 - Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391926) 
 - Memory leak seen after using storcli and unloading the driver(SCGCQ01479414) 
 - NVMe task management command is not executed as per NVDAT settings(SCGCQ01524245) 
 - SAS3 PH2 Linux: In dkms installation mode the driver loading is not successful on RHEL 5.8 32 bit(SCGCQ00314484) 
 - OVM 3.2.1 OS kernel fails to allocate the memory requested for higher queue depth(SCGCQ00518928) 
 - Used GFP_KERNEL flag instead of GFP_ATOMIC flag while allocating memory for event notification reply data structure at ISR level(SCGCQ00552999) 
 - Linux mpt3sas: Don't block the drive when drive is under device addition process at SML(SCGCQ00846228) 
 - Refcount fw_events and fix unsafe list usage(SCGCQ00933591) 
 - Linux IT SAS3.5 ph3 mpt3sas: Target number for vSES is incremented after host reset(SCGCQ01255996) 
 - Fix for file system going to read-only mode when controller is resetted(SCGCQ01315476) 
 - Fix SAS drives going for Spin Down when module param allow_drive_spindown is set to 3(SCGCQ01337377) 
 - Driver Unload command does not exit when connected drives are disconnected while unloading driver(SCGCQ01403879) 
 - wrong sizeof argument being passed to sizeof(	▪ (SCGCQ01484567) 
 - Code refactor: memory allocation,setting status for incorrect command,accesing dev struct after decrementing its ref count.(SCGCQ01558459) 
 - The log_info constant is supposed to be IOP_LOGINFO_CODE_TASK_TERMINATED rather than the non-sensical 0x1CA86D0(SCGCQ00301838 port of ) 
 - writeq changed back to 64bit pci transfers(SCGCQ00301840 port of SCGCQ00259827) 
 - Staged Device Discovery functionality of driver not working(SCGCQ00305273 port of SCGCQ00282024) 
 - Coexistence of GEN 2 and GEN 3 driver conflicts on OVM 3.0.3(SCGCQ00335262 port of SCGCQ00330431) 
 - Coexistence of GEN 2 and GEN 3 driver conflicts on OVM 3.0.3(SCGCQ00340303 port of SCGCQ00330431) 
 - Add support for configurable Chain Frame Size.(SCGCQ00933600 port of SCGCQ00929253) 
 - Remove unnecessary synchronize_irq(SCGCQ01079113 port of SCGCQ01077560) 
 - Message displayed improperly in var log(device_block failed with return(27(SCGCQ01099928 port of SCGCQ01096464) 
 - Replace #if defined preprocessor used for "ktime_to_ms" function with Kernel version, where "ktime_to_ms" func is defined(SCGCQ01105904 port of SCGCQ01100154) 
 - device_remove_in_progress check is not implemented in IOCTL path(SCGCQ01105910 port of SCGCQ01079361) 
 - Linux mpt3sas: Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device(SCGCQ01105911 port of SCGCQ01100134) 
 - Upstream mpt3sas - Fix warnings exposed by W=1(SCGCQ01179535 port of SCGCQ01154412) 
 - Linux IT Ph14 mpt3sas: Observed kernel panic while performing shutdown operation followed by immediate PCI device hotplug(SCGCQ01380972 port of SCGCQ01348068) 
 - Port Upstream fix: Fix kernel panic during expander reset (Fix for scsi_host_find_tag(SCGCQ02116554 port of SCGCQ02085406) 
 - When staged discovery is enabled, post diag reset, devices get added, removed and then again added with new target ids.(SCGCQ00301851 port of SCGCQ00288449) 
 - ASD diaganostic trigger support fake event needs to change(SCGCQ00301855 port of SCGCQ00269303) 
 - missing delay not getting set during system bootup(SCGCQ00324675 port of SCGCQ00314867) 
 - LSI SAS HBA 6Gb adapters fails Read Capacity 16 command sent to Tape drive(SCGCQ00341420 port of SCGCQ00295267) 
 - Add support for OEL 6.4.(SCGCQ00454977 port of SCGCQ00411878) 
 - device_blocked, handle(0x0027(SCGCQ00571402 port of SCGCQ00481285) 
 - Drives attached to the expander are not discovered(SCGCQ00571418 port of SCGCQ00567801) 
 - Add branding string support for OEM custom HBA's(SCGCQ00637547 port of SCGCQ00566744) 
 - Fixed the defect by adding a check for other LUNS even if LUN0 is offline(SCGCQ00703194 port of SCGCQ00664374) 
 - Driver compiles on 4.4 kernel with no errors(SCGCQ01073774 port of SCGCQ01066197) 
 - Remove usage of 'struct timeval'(SCGCQ01079115 port of SCGCQ01078582) 
 - Upstream mpt3sas - Eliminate conditional locking in mpt3sas_scsih_issue_tm((SCGCQ01179583 port of SCGCQ01154336) 
 - Addition of two events to Active Cable Exception Event Data(SCGCQ01185776 port of SCGCQ01181276) 
 - Upstream scsi: rename SCSI_MAX_{SG, SG_CHAIN}_SEGMENTS and "DEFINE_PCI_DEVICE_TABLE" macro is deprecated.(SCGCQ01203757 port of SCGCQ01198899) 
 - Linux IT Ph14 mpt3sas: Observed kernel panic during HBA hot plug operation just before issuing system shutdown operation(SCGCQ01380973 port of SCGCQ01366025) 
 - Linux IT Ph14 mpt3sas: Poweroff command fails to shutdown the host post surprise removal of controller(SCGCQ01380975 port of SCGCQ01352902) 
 - Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconde(SCGCQ01868047 port of SCGCQ01867387) 
 - Red Hat 6.3 support(SCGCQ00361916 port of SCGCQ00297615) 
 - Added support to issue a Start Stop Unit command (stopping the target(SCGCQ00423262 port of SCGCQ00394200) 
 - Unbalanced reply queue to CPU mapping when max_msix_vectors is set(SCGCQ00448247 port of SCGCQ00448225) 
 - Target Reset Fails during the disk addition(SCGCQ00481890 port of SCGCQ00481268) 
 - Drive is not showing up in the OS after powering on with 9207-8e with Bobcat Expander(SCGCQ00487138 port of SCGCQ00419910) 
 - Component drives of a Volume goes missing once the volume is deleted(SCGCQ00487140 port of SCGCQ00468602) 
 - Linux mpt3sas: Observed kernel panic during driver load time on RHEL5.11 OS(SCGCQ00880259 port of SCGCQ00878516) 
 - Can't get 1MB IO size using mpt2sas driver on OEL UEK or UEK2(SCGCQ00898466 port of SCGCQ00530826) 
 - OS not discovering all drives in dual node configuration(SCGCQ01026842 port of SCGCQ00776162) 
 - Update Initial Ref Tag with correct value for 4K PI drives (kernels < 3.18 (SCGCQ01073780 port of SCGCQ01066189) 
 - Don't overreach ioc->reply_post[] during initialization , which results in "slab-out-of-bounds" dump on final iteration.(SCGCQ01079114 port of SCGCQ01077566) 
 - Avoid mpt3sas_transport_port_add NULL parent_dev(SCGCQ01110265 port of SCGCQ01109669) 
 - Linux : Enclosure Handles are not updated for SAS device during diag reset(SCGCQ01372661 port of SCGCQ01326058) 
 - Linux IT Ph14 mpt3sas: Added Hot-Plug Surprise removal support on IOCs(SCGCQ01383826 port of SCGCQ01341334) 
 - mpt3sas: Disable DIX support by default.(SCGCQ01465762 port of SCGCQ01465665) 
 - Turning-off Log_info available bit in ioc_status for mpi_trigger(SCGCQ00301847 port of SCGCQ00279997) 
 - Fixid Packaging doesn't contain the RPM for SLES10/SLES11(SCGCQ00361981 port of SCGCQ00356161) 
 - Driver does not comply with the updated timing requirements for issuing a Hard Reset.(SCGCQ00361982 port of SCGCQ00316021) 
 - Intelligent Cluster: Linux Kernel Panic on SLES 11.2 with 9201-16e(SCGCQ00376665 port of SCGCQ00356062) 
 - _base_get_ioc_facts: failed going to ready state (ioc_state=0x20000000(SCGCQ00571424 port of SCGCQ00568563) 
 - Fix driver compilation errors on RHEL5 kernels.(SCGCQ01080913 port of SCGCQ01074408) 
 - Increase NVMe device queue depth to remove performance bottleneck in the driver(SCGCQ01316459 port of SCGCQ01305414) 
 - Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01884875 port of SCGCQ01875700) 
 - Add Diagnostic Trigger management and new DiagService Event to Linux Driver(SCGCQ00301829 port of SCGCQ00226997) 
 - Verifying the proper memory allocation for "ioc->chain_lookup" in the function _base_allocate_memory_pools(SCGCQ00301835 port of SCGCQ00249415) 
 - move the scsi_host_put to the right place(SCGCQ00301844 port of SCGCQ00271607) 
 - Diag Service: No triggers events fired for every reboot of system with Co-Existance of CCOH and DaigService(SCGCQ00301846 port of SCGCQ00257763) 
 - Added support for fedora17(SCGCQ00361920 port of SCGCQ00251438) 
 - Added support for CentOS 6.3(SCGCQ00361921 port of SCGCQ00251425) 
 - New Ubuntu12.04 linux OS currenty support(SCGCQ00361924 port of SCGCQ00251411) 
 - Update the usage of the function pci_remove_bus_device(SCGCQ00394683 port of SCGCQ00359149) 
 - SLES 11 SP3 Beta4 Support(SCGCQ00420593 port of SCGCQ00408139) 
 - When a device is in a non-operational state wait for EEH recovery completion before removing the dead IOC function(SCGCQ00425367 port of SCGCQ00399592) 
 - Drive Pull/Insert Issue - START_UNIT timeouts(SCGCQ00483262 port of SCGCQ00481271) 
 - Kernel panic while upgrading the firmware online(SCGCQ00550047 port of SCGCQ00526468) 
 - Host need to complete SCSI command with DID_RESET status instead of DID_SOFT_ERROR under certain conditions.(SCGCQ00694147 port of SCGCQ00693983) 
 - In DIF-TYPE1-IP mode, the APP tag is zero'd on the wire.(SCGCQ00695354 port of SCGCQ00691983) 
 - Linux mpt3sas: Modified the OEM's HBA product name(SCGCQ00788347 port of SCGCQ00787798) 
 - Unable to disable a phy by setting corresponding phy's 'enable' sysfs attribute to zero(SCGCQ00845286 port of SCGCQ00842931) 
 - Linux mpt3sas: Don't block the Enclosure device(SCGCQ00898464 port of SCGCQ00896193) 
 - Synchronize timed-out IO and Task Management functions(such as task_abort & target_reset(SCGCQ01073779 port of SCGCQ01066194) 
 - set num_phys after allocating phy[] space (SCGCQ01110264 port of SCGCQ01109662) 
 - Upstream mpt3sas - Ensure the connector_name string is NUL-terminated(SCGCQ01185771 port of SCGCQ01154419) 
 - Set maximum transfer length per IO to 4MB for VDs(SCGCQ01210393 port of SCGCQ01072631) 
 - DIF Patchs from Oracle(SCGCQ00301830 port of SCGCQ00255629) 
 - Possible deadlock in IOCTL path(SCGCQ00301842 port of SCGCQ00266321) 
 - smp_processor_id(SCGCQ00301843 port of SCGCQ00268580) 
 - Update the usage of the function scsi_internal_device_unblock(SCGCQ00331941 port of SCGCQ00331929) 
 - New Ubuntu11.10 linux OS currenty support(SCGCQ00361922 port of SCGCQ00302125) 
 - Create phase 13 GCA generic point release for OEL UEK R2(SCGCQ00395417 port of SCGCQ00258229) 
 - Driver is using device handle instead of enclosure slot method for clearing of PFA status(SCGCQ00435927 port of SCGCQ00435028) 
 - Linux mpt2sas: Process works from firmware work-queue sequentially(SCGCQ00772791 port of SCGCQ00769798) 
 - Linux mpt2sas: Driver initialization hangs when pci_enable_msix API fails to enable MSIX vector(SCGCQ00773759 port of SCGCQ00760760) 
 -(SCGCQ00933617 port of SCGCQ00926726) 
 - Upstream mpt3sas - Don't spam logs if logging level is 0(SCGCQ01194636 port of SCGCQ01155651) 
 - Ph14 Linux Driver : Active Cable Exception events are logged by driver for attachment of Passive cables.(SCGCQ01210253 port of SCGCQ01205383) 
 - Linux IT Ph14: Enable Active Cable Exception Event for Fury/Invader(SCGCQ01237382 port of SCGCQ01237340) 
 - Linux SAS35 Ph3 : By default disable multipath support for SAS3.5 HBA's too.(SCGCQ01316220 port of SCGCQ01301732) 
 - Not able to update manpage 11 when try to update FW from OS.(SCGCQ01729592 port of SCGCQ01639219) 
 - 2012 source code copyright(SCGCQ00301826 port of SCGCQ00254805) 
 - when async scanning mode is enabled and scanning is in progress devices are removed and their transport layer entries are not removed.(SCGCQ00380178 port of SCGCQ00379998) 
 - Clear PFA Status on SGPIO when PFA Drive is Removed or Replaced.(SCGCQ00423261 port of SCGCQ00392963) 
 - Linux mpt2sas: A new driver module Parameter is added to Enable/Disable EEDP Support(SCGCQ00423263 port of SCGCQ00295288) 
 - Updated the set_affinity.sh to have a support for more than 32 CPU cores systems(SCGCQ00438827 port of SCGCQ00427368) 
 - Update the usage of the function scsi_internal_device_unblock((SCGCQ00462789 port of SCGCQ00461953) 
 - failure at _transport_set_identify and mpt2sas_transport_port_add(SCGCQ00571398 port of SCGCQ00497017) 
 - Add branding string support for OEM custom HBA's(SCGCQ00871877 port of SCGCQ00867336) 
 - Remove SRIOV specific code from mpt3sas driver and update buildkits accordingly.(SCGCQ01203756 port of SCGCQ01197731) 
 - RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0(SCGCQ01504666 port of SCGCQ01496368) 
 - Driver sets queue_depth=254(SAS_QUEUE_DEPTH(SCGCQ01763013 port of SCGCQ01741671) 
 - driver oops associated with the max_queue_depth command line option set too small(SCGCQ00301837 port of SCGCQ00258989) 
 - Providing a negative value to sdev_queue_depth parameter leads to incorrect queue depth for a SAS drive.(SCGCQ00301848 port of SCGCQ00279155) 
 - Linux driver : updated initrd.img doesn't contain newly installed mpt2sas driver module(SCGCQ00332653 port of SCGCQ00332288) 
 - Debian6.0.5 Linux Support for 32 and 64 bit(SCGCQ00361923 port of SCGCQ00251412) 
 - Add support for OEL 6.3.(SCGCQ00361926 port of SCGCQ00303161) 
 - Oracle Linux 5.9 Support(SCGCQ00454974 port of SCGCQ00401299) 
 - Linux mpt2sas: Added support for OVM3.2.1 OS(SCGCQ00454976 port of SCGCQ00411913) 
 - Kernel Panic observed after issuing controller diag reset.(SCGCQ00526798 port of SCGCQ00501333) 
 - Only 8 MSIX vectors are enabled for SAS3 HBAs on a 32 core machine(SCGCQ01107215 port of SCGCQ01106942) 
 - Missing curly braces on if statement to print message when there is insufficient power for active cable.(SCGCQ01110263 port of SCGCQ01109643) 
 - Upstream mpt3sas - Eliminate dead sleep_flag code.(SCGCQ01179606 port of SCGCQ01154385) 
 - DID_SOFT_ERROR issue encountered on SATA RAID1 during testing 12.100.00.00(SCGCQ01284610 port of SCGCQ01284381) 
 - Linux mpt3sas: Enumeration of drives for OEM specific controller(SCGCQ01408565 port of SCGCQ01318421) 
 - IO Timeouts observed while running IO and parallel TaskMgmt test with SATA drives(SCGCQ01522289 port of SCGCQ01497972) 
 - mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is going on(SCGCQ01827523 port of SCGCQ01819327) 
	
EnhancementRequests 	
 - Change Diagnostic Toolbox CLI SGL format to IEEE (to match MPI 2.5.1 spec change(SCGCQ00314987) 
 - Added mpt3sas driver support for fedora18 OS(SCGCQ00442462) 
 - Added code to display Location of End Device.(SCGCQ00452326) 
 - Added UEK3 (v3.8.13-16)(SCGCQ00552232) 
 - Oracle Linux 5.10 Support(SCGCQ00552253) 
 - Added mpt3sas driver support for Citrix 6.2 OS(SCGCQ00552276) 
 - Added support for Ubuntu14.04(SCGCQ00661419) 
 - Added CENTOS7.0 (x86_64(SCGCQ00675458) 
 - Updating the device removal handshake protocol only on VF drivers(SCGCQ00696568) 
 - Add branding string support for OEM custom HBA's(SCGCQ00718659) 
 - Update upstream Linux mpt3sas: [PATCH] block: Kill bio_segments(SCGCQ00778584) 
 - Update upstream Linux mpt3sas: [PATCH] [SCSI] mpt3sas: remove unused variables(SCGCQ00778631) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's(SCGCQ00793599) 
 - Linux combined src: Disable temperature fault functionality for SAS2 HBA's(SCGCQ00915064) 
 - Linux SAS3.5 phase2 IT: Added support for UNMAP commands for NVMe drives via fast-path(SCGCQ01190581) 
 - Merge MPI end point linux driver to Phase3 sas35 mainline and later to upstrea(SCGCQ01224602) 
 - Pre-allocate RDPQ Array at driver boot time(SCGCQ01297392) 
 - Driver support for OEL 7.4_UEK (4.1.12-94.3.9.el7uek(SCGCQ01396745) 
 - OS driver support for Oracle Linux 7.5 - SAS3 PH 16, SAS3.5 Ph 8(SCGCQ01586104) 
 - Call t10_pi_ref_tag for RHEL 8 kernels(SCGCQ02069530) 
 - Test Unit Ready retries causes slow discovery(SCGCQ00406610) 
 - Added RHEL5.10 support(SCGCQ00442446) 
 - Added mpt3sas driver support for Centos 6.5 OS(SCGCQ00571454) 
 - Addnew module parameter to allow /disallow host driver to issue SCSI commands to bring up drive.(SCGCQ00609923) 
 - Added support for OVM 3.3.1(SCGCQ00666996) 
 - Linux mpt3sas: Porting upstream patches to mainline(SCGCQ00825572) 
 - OS Driver Support for Ubuntu 15.04(SCGCQ00826237) 
 - Fedora 22 OS Support is added(SCGCQ00846536) 
 - Linux mpt3sas_Phase 10 PA#1: Dropping support for RHEL5 and SLES10 distro and Unified binary support for RHEL,OEL & CentOS.(SCGCQ00864228) 
 - Linux combined src: Added mpt2sas driver definitions to combined driver src(SCGCQ00914998) 
 - MPI header update with new supported controller addition(SCGCQ01064186) 
 - Interim Experimental Change: Add code to detect Non first page unaligned SGE for NVMe drives and panic.(SCGCQ01080920) 
 - 0001 - mpt3sas: set default value for cb_idx(SCGCQ01300828) 
 - 0006 - mpt3sas: always use first reserved smid for ioctl passthrough and second reserved smid for internal scsi io commands(SCGCQ01300840) 
 - Report Package Version from HBA Driver(SCGCQ01445879) 
 - Skip pending I/Os issued to NVMe drives while processing Broadcast Async Event(SCGCQ01558613) 
 - mpt3sas: Do not wait for IOC to become operational if HBA is unplugged(SCGCQ01681422) 
 - OS driver support for XenServer7.4 SAS3 PH 16, SAS3.5 Ph 8(SCGCQ01750033) 
 - Linux IT Ph9 mpt3sas: Added mpt3sas driver support for SLES15 OS(SCGCQ01828337) 
 - mpt3sas: Ph9 - Add OEL 6.10 support(SCGCQ01870215) 
 - Modified the SAS3 Linux Driver such that the SAS2 and SAS3 drivers can co-exist.(SCGCQ00300298) 
 - Added Red Hat 5.9 support(SCGCQ00377019) 
 - Added mpt3sas driver support for Citrix 6.1 OS(SCGCQ00442454) 
 - Add support to MPI - ReplyDescriptorPostQueueArray defined in IOC Init Request Message(SCGCQ00467389) 
 - Add branding string support for Intel custom HBA's(SCGCQ00546703) 
 - Added SLES12 RC3 support ( only x86_64)(SCGCQ00672325) 
 - Provide an option to enable / disable spin down SSD and HDD devices while unloading driver.(SCGCQ00695289) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's(SCGCQ00780483) 
 - Added SLES12 GM Support (only X86_64(SCGCQ00785459) 
 - Linux mpt3sas: Make use of additional HighPriorityCredit number of message frames for sending SCSI IO's(SCGCQ00899842) 
 - Linux combined src: Don't print Enclosure level and connector name information for SAS2 HBA's(SCGCQ00915060) 
 - Linux combined src: Disable mapping of SAS devices to VFs SRIOV feature for SAS2 HBA's(SCGCQ00915109) 
 - Linux combined src: Retain same module parameters names which were their before for mpt2sas driver(SCGCQ00916328) 
 - Linux IT/IR: Merge mpt2sas driver in to mpt3sas driver module.(SCGCQ00955258)
 - Linux SAS3.5 IT: Limit 0x2100 FW fault by updating host index up on reaching the thresh hold value(SCGCQ01149963) 
 - Linux SAS3.5 IT Ph2: Block the drive after recieving any ATA pass-though command for that driver and unblock it after completion of the command(SCGCQ01218960) 
 - 0007 - mpt3sas: lockless command submission(SCGCQ01300843) 
 - 0009 - mpt3sas: Enable tag support for all supported kernels	(SCGCQ01300853) 
 - Upstream mpt3sas: Fix memory allocation failure test in 'mpt3sas_base_attach(SCGCQ01454958) 
 - Upstream mpt3sas: scsi_transport_sas: switch to bsg-lib for SMP passthrough(SCGCQ01606945) 
 - Upstream mpt3sas: Fix function prototypes for module_param_call(SCGCQ01607482) 
 - Added support for Atlas Gen4 PCIe switches in MPT driver environments for Linux.(SCGCQ01731329) 
 - Upstream: Added an i/o barrier(SCGCQ01828734) 
 - Updated the build kits to support SAS2 Phase 14 level(SCGCQ00300292) 
 - Added SLES11 SP3 OS support(SCGCQ00454992) 
 - Add support to log message when Temperature Threshold exceeds for any Sensor.(SCGCQ00604649) 
 - Performance improvement by changing Affinity change and adding Host lock less mode(SCGCQ00610127) 
 - Added support for Ubuntu13.0(SCGCQ00614076) 
 - Add branding string support for custom HBA's(SCGCQ00636608) 
 - Added RHEL7.0 support(SCGCQ00672310) 
 - Added OEL7.0 Support(SCGCQ00673317) 
 - Linux mpt3sas: Detect the SMART Error SATA drive in the Topology and turn on it's corresponding PFA LED(SCGCQ00791340) 
 - Added SLES11sp4 GM Support(SCGCQ00826215) 
 - Added UEK3 Update5 (v3.8.13-68(SCGCQ00826232) 
 - Adding Intruder specific code to the Gen3 Linux Phase 9 driver(SCGCQ00831649) 
 - Debian 8.0 OS support-SAS3 Phase 10(SCGCQ00856661) 
 - Linux combined src: For an IO, build MPI SGL LIST for SAS2 HBA's and build IEEE SGL LIST for SAS3 HBA's(SCGCQ00915044) 
 - Linux combined src: Don't send PHYDISK_HIDDEN Raid Action request on SAS2 HBA's(SCGCQ00915050) 
 - Linux combined src: Disable DIX feature specific code for SAS2 HBA's(SCGCQ00915061) 
 - Linux combined src: Disable Target mode hooks from combined driver src(SCGCQ00915067) 
 - Prevent sending I/Os with NVMe PRP if non first page unaligned SGE is detected(SCGCQ01080930) 
 - Linux SAS3.5 Ph2: Enable DIX support(SCGCQ01200312) 
 - Linux SAS3.5 IT Ph2: Set NVMe device queue properties in such a way to reduce holes in sges(SCGCQ01224810) 
 - Added support for XenServer 7.1.(SCGCQ01289850) 
 - 0005 - mpt3sas: Introduce mpt3sas_get_st_from_smid(SCGCQ01300838) 
 - 0008 - mpt3sas: create separate lookup table for NVMe PRP list(SCGCQ01300851) 
 - Optimize I/O memory consumption in driver(SCGCQ01388190) 
 - Enhanced handling of DMA allocation, If the allocation does not fit within same 4GB(SCGCQ01388961) 
 - Upstream mpt3sas: Create two versions of scsi_internal_device_unblock((SCGCQ01447644) 
 - Upstream mpt3sas: fix format overflow warning(SCGCQ01454955) 
 - Added support for RHEL7.5 GA (3.10.0-862.el7(SCGCQ01719072) 
 - Linux IT Phase9 mpt3sas: Ignore processing of Phy having target not responding reason code while processing re-queued event(SCGCQ01892634) 
 - Linux IT Phase9 mpt3sas: Enable PCIe switch enumeration by default for all kernel versions(SCGCQ02018676) 
 - Added DIX support of the Linux operating system to the driver.(SCGCQ00262891) 
 - Add 96 MSI-X vector support for Invader C0(SCGCQ00371782) 
 - Added mpt3sas driver support for fedora19 OS(SCGCQ00552267) 
 - Added UEK3 Update3 (v3.8.13-44(SCGCQ00675434) 
 - Target Numbers of mapped drives on VFs won't increase after diag reset on PF	(SCGCQ00689554) 
 - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago(SCGCQ00729462) 
 - Linux combined src: Defined 'hba_mpi_version_belonged' IOC variable to differnate the each gerenation HBA's specific functionalities(SCGCQ00915025) 
 - Linux combined src: Remove SCSI_MPT3SAS_LOGGING entry from Kconfig files	▪ (SCGCQ00915035) 
 - RHEL 7.3 OS Support for SAS3.5 Phase 2(SCGCQ01218181) 
 - Added mpt3sas driver support for OEL6.9(SCGCQ01289003) 
 - 0003 - mpt3sas: separate out _base_recovery_check(SCGCQ01300833) 
 - Reducing the number of times enclosure config page read request sent by driver(SCGCQ01357382) 
 - Increase event log buffer to support 24 port HBA's to avoid buffer overflow.(SCGCQ01368517) 
 - NVMe Task Management - Controller Reset Support (SCS(SCGCQ01445901) 
 - Upstream: mpt3sas: clarify mmio pointer types (Fix compiler warning(SCGCQ01686081) 
 - Phase8: Fix sparse warnings of inhouse mpt3sas driver.(SCGCQ01729697) 
 - SAS3.5 Phase9: Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL(SCGCQ01828339) 
 - Upstream: Fix _transport_smp_handler(SCGCQ01828766) 
 - Use t10_pi_ref_tag and compatible _transport_smp_handler API in SLES15SP1(SCGCQ02070829) 
 - Added mpt3sas driver support for RHEL 6.5 OS(SCGCQ00552245) 
 - Added OEL6.5 Support(SCGCQ00552260) 
 - Added UEK3 U1 (v3.8.13-26(SCGCQ00571510) 
 - Added SRIOV support for both Xen and KVM hypervisor.(SCGCQ00627105) 
 - Added UEK3 Update2 (v3.8.13-35(SCGCQ00654016) 
 - Added RHEL 6.6 Support(SCGCQ00675448) 
 - Remove kernel support older than N-3 kernel updates, where N is latest kernel update release.(SCGCQ00696790) 
 - Updated MPI 2.5 Release: MPI 2.5 Rev K (2.5.6(SCGCQ00709717) 
 - Added Oracle Linux 5.11 Support(SCGCQ00775653) 
 - Update upstream Linux mpt3sas: [PATCH] mpt3sas: Use pci_enable_msix_exact(SCGCQ00776753) 
 - Update upstream Linux mpt3sas: [PATCH] block: Convert bio_for_each_segment(SCGCQ00778582) 
 - Added UEK3 Update4 (v3.8.13-55(SCGCQ00788014) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's.(SCGCQ00793614) 
 - Linux SAS3: Add RHEL 6.7 GA Support(SCGCQ00848126) 
 - Linux combined src: Manage MSI-X vectors according to HBA device type(SCGCQ00915056) 
 - Linux combined src: Add OEM's SAS2 HBA's PnP ID Branding names(SCGCQ00915065) 
 - Active cable exception handling in mpt3sas driver:(SCGCQ01008402) 
 - Ventura IT Linux Driver: Update MPI 2.6.07 specification, and 2.00.45 header files(SCGCQ01133212) 
 - Reduce memory footrpints in kdump kernel.(SCGCQ01237163) 
 - 0004- mpt3sas: open code _scsih_scsi_lookup_get(SCGCQ01300836) 
 - Added mpt3sas driver support for RHEL6.9	(SCGCQ01316324) 
 - Added support for SAS Device Discovery Error Event.(SCGCQ01354911) 
 - Upstream mpt3sas: Split scsi_internal_device_block(SCGCQ01447640) 
 - mpt3sas: Added new thread called hot plugged watchdog which will poll for whether HBA device is unplugged or not(SCGCQ01681425) 
 - Linux Drivers: MPI2.5 Update Rev U (2.0.26(SCGCQ00304398) 
 - Added Debian7.0 Linux OS Support(SCGCQ00552280) 
 - Added mpt3sas driver support for fedora20(SCGCQ00571464) 
 - Updated MPI 2.5 Release: MPI 2.5 Rev J (2.5.5(SCGCQ00653281) 
 - Added OEL6.6 Support(SCGCQ00721141) 
 - Added RHEL5.11 Support(SCGCQ00775576) 
 - Update upstream Linux mpt3sas: [PATCH] mpt3sas: delay scsi_add_host call to work with scsi-mq(SCGCQ00778620) 
 - Linux mpt3sas: Added mpt3sas driver support for RHEL7.1 OS(SCGCQ00787975) 
 - Linux Mpt3sas SRIOV: Use serial number as primary key to uniquely identify the SATA drives in device persistence mapping mode(SCGCQ00813146) 
 - Linux mpt3sas: Added mpt3sas driver support for OEL7.1 OS (SCGCQ00838951) 
 - Ph 11 LINUX_MPT3SAS : Dropping support for few distros as per MR OS_Support matrix.(SCGCQ00900247) 
 - Linux conbined src: Move Gen3 HBA's device registration with PCI, SML and IOCTL API's to separate mpt3sas_module.c file(SCGCQ00915016) 
 - Linux Combined src: Added csmi hooks and it will be enabled only for SAS2 HBA's(SCGCQ00915063) 
 - SLES 12 SP2 OS Support for SAS3.5 Phase 2(SCGCQ01154063) 
 - Linux Ventura Phase2: Add support for IO Unit Control, Shutdown message(SCGCQ01165691) 
 - Linux SAS35 IT: Added driver support for Dual/multi-path typologies(SCGCQ01237381) 
 - 00010 - mpt3sas: allocate as many chains as needed and remove chain list maintenance overhead(SCGCQ01300854) 
 - Ph5 : SLES12 SP3(4.4.73-5(SCGCQ01396754) 
 - Linux IT Phase9 mpt3sas: Enable irq poll in Linux driver to avoid CPU hard and soft lockups(SCGCQ01571359) 
 - mpt3sas: code refactor - move section of code which waits for IOC to be in operational state into a separate function(SCGCQ01681420) 
 - Linux IT Phase9 mpt3sas: Added driver support for Ambrosia NVMe Switch Adapter(SCGCQ01891714) 
 - Added Red Hat 6.4 support(SCGCQ00376609) 
 - Added mpt3sas driver support for Centos 6.4 OS(SCGCQ00552285) 
 - When the IOC over heats, driver needs to flush the IOs and panic.(SCGCQ00654911) 
 - When memory allocation for SCSI command message frame request tracker queue fails, driver should be capable lowering the queue depth and allocate memory.(SCGCQ00693434) 
 - VF drivers doesn't need to retrieve the BIOS pages(SCGCQ00698258) 
 - 3008 IT: Add OEM String to Driver for OEM Board Design(SCGCQ00860516) 
 - Linux mpt3sas: Include changes of MPI 2.5 Rev M and MPI 2.6 Rev E specifications and 2.00.39 headers(SCGCQ00899809) 
 - Linux combined src: Disabled SATA SMART polling feature for SAS2 HBA's(SCGCQ00915058) 
 - Linux combined src: Ported WarpDrive HBA support from mpt2sas driver src(SCGCQ00922147) 
 - Linux Combined src: Ported fix for setpci reset kernel oops from mpt2sas src(SCGCQ00922149) 
 - OEL 7.3 OS Support for SAS3.5 Phase 2(SCGCQ01154077) 
 - Linux IT mpt3sas: Recognize and act on IO's iopriority info(SCGCQ01237164) 
 - 0002 - mpt3sas: use list_splice_init(SCGCQ01300832) 
 - Upstream mpt3sas: switch to pci_alloc_irq_vectors(SCGCQ01367469) 
 - Upstream mpt3sas: fix dma_addr_t casts(SCGCQ01541636) 
 - Added support for XenServer 7.3 OS.(SCGCQ01554011) 
 - OS Driver Support for Ubuntu 18.04- SAS3.5 PH 8 / SAS3 PH 16	(SCGCQ01586127) 
 - Upstream mpt3sas: Do not mark fw_event workqueue as WQ_MEM_RECLAIM.(SCGCQ01686075) 
 - mpt3sas: wait for and flush running commands on shutdown/unload (Upstream Patch(SCGCQ01686096) 
 - Change attribution language from Avago to Broadcom and update copyright end year(SCGCQ01757358) 
 - Upstream: Introduced struct "mpt3sas_nvme_cmd"(SCGCQ01828741) 
 - Add RHEL 8 OS driver support(SCGCQ02136688) 
				 
version	28.00.03.00	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
Linux driver-PH9

defects:
- Driver load fails on big endian systems (SPARC64).(SCGCQ01836661)
- Linux IT Ph9 mpt3sas: Fix Unknown symbol __umoddi3 dependency error while loading the driver(SCGCQ01869644)
- Phase 9: Marking transport command as completed though the command is in use.(SCGCQ01829803)
- Phase9 Linux Driver:- Include RHEL 7.6 & SLES12SP4 binaries to "28.00.01.00-1".(SCGCQ02035467)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconds(SCGCQ01868047 port of SCGCQ01867387)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL(SCGCQ01856662 port of SCGCQ01784898)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout
>= 512 seconds(SCGCQ01868049 port of SCGCQ01867387)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is
going on(SCGCQ01905582 port of SCGCQ01819327)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x
vectors on > 16 logical CPU machine(SCGCQ01906874 port of SCGCQ01473904)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01905585 port of SCGCQ01875700)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is
going on(SCGCQ01827523 port of SCGCQ01819327)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01884875 port of SCGCQ01875700)
 - Port Upstream fix: Fix kernel panic during expander reset (Fix for scsi_host_find_tag() returning invalid
address)(SCGCQ02116554 port of SCGCQ02085406)

EnhancementRequest:
- Added support for Atlas Gen4 PCIe switches in MPT driver environments for Linux..(SCGCQ01731329)
- Upstream: Added an i/o barrier.(SCGCQ01828734)
- SAS3.5 Phase9: Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD.()
for RHEL, SLES and OEL.(SCGCQ01828339)
- Upstream: Fix _transport_smp_handler() error path.(SCGCQ01828766)
- Upstream: Introduced struct "mpt3sas_nvme_cmd".(SCGCQ01828741)
- Linux IT Ph9 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01828337)
- Linux IT Phase9 mpt3sas: Enable irq poll in Linux driver to avoid CPU hard and soft lockups.(SCGCQ01571359)
- mpt3sas: Ph9 - Add OEL 6.10 support.(SCGCQ01870215)
- Linux IT Phase9 mpt3sas: Ignore processing of Phy having target not responding reason code.()
while processing re-queued event.(SCGCQ01892634)
- Linux IT Phase9 mpt3sas: Added driver support for Ambrosia NVMe Switch Adapter.(SCGCQ01891714)
- Linux IT Phase9 mpt3sas: Enable PCIe switch enumeration by default for all kernel versions.(SCGCQ02018676)
- Call t10_pi_ref_tag for RHEL 8 kernels.(SCGCQ02069530)
- Use t10_pi_ref_tag and compatible _transport_smp_handler API in SLES15SP1.(SCGCQ02070829)
				 
					 
version	27.125.01.00-1	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
IR/IT (MPT3) – Ph 16 (new)
					 
Defects
- Driver load fails on big endian systems (SPARC64).(SCGCQ01836661)
- Fix, False timeout prints for ioctl and other internal commands during controller reset.(SCGCQ01555936)
- Ventura: As per MPI spec use Supplemental Reply Post Host Index Register(combined reply queue) when MSI-X vectors > 16.(SCGCQ01629402)
- Fix compilation error for SLES11.(SCGCQ01698115)
- Driver compilation fails on latest upstream kernel(>= v4.17), due to changes in "queue_flag_set_unlocked" API.(SCGCQ01799543)
- Code refactor: memory allocation,setting status for incorrect command,accesing dev struct after decrementing its ref count.(SCGCQ01558459)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01615533 port of SCGCQ01473904)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01856662 port of SCGCQ01784898)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconds.(SCGCQ01868049 port of SCGCQ01867387)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is going on.(SCGCQ01905582 port of SCGCQ01819327)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01729592 port of SCGCQ01639219)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01763013 port of SCGCQ01741671)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode.(SCGCQ01905585 port of SCGCQ01875700)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01906874 port of SCGCQ01473904)

EnhancementRequests:
- OS driver support for Oracle Linux 7.5 - SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01586104)
- Added support for RHEL6.10 GA(2.6.32-754.el6).(SCGCQ01828835)
- Skip pending I/Os issued to NVMe drives while processing Broadcast Async Event.(SCGCQ01558613)
- mpt3sas: Do not wait for IOC to become operational if HBA is unplugged.(SCGCQ01681422)
- OS driver support for XenServer7.4 SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01750033)
- Upstream mpt3sas: scsi_transport_sas: switch to bsg-lib for SMP passthrough.(SCGCQ01606945)
- Upstream mpt3sas: Fix function prototypes for module_param_call(SCGCQ01607482)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01719072)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Upstream: mpt3sas: clarify mmio pointer types (Fix compiler warning).(SCGCQ01686081)
- Phase8: Fix sparse warnings of inhouse mpt3sas driver.(SCGCQ01729697)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- mpt3sas: Added new thread called hot plugged watchdog which will poll for whether HBA device is unplugged or not.(SCGCQ01681425)
- mpt3sas: code refactor - move section of code which waits for IOC to be in operational state into a separate function.(SCGCQ01681420)
- Linux IT Ph6 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01839348)
- Upstream mpt3sas: fix dma_addr_t casts.(SCGCQ01541636)
- Added support for XenServer 7.3 OS.(SCGCQ01554011)
- OS Driver Support for Ubuntu 18.04- SAS3.5 PH 8 / SAS3 PH 16.(SCGCQ01586127)
- Upstream mpt3sas: Do not mark fw_event workqueue as WQ_MEM_RECLAIM.(SCGCQ01686075)
- mpt3sas: wait for and flush running commands on shutdown/unload (Upstream Patch).(SCGCQ01686096)
- Change attribution language from Avago to Broadcom and update copyright end year.(SCGCQ01757358)


version	27.125.01.00	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	

					 
version	25.125.02.00	 -- Moderate Impact/Low Probability of Occurrence
-------------------		
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)	

			
version	25.125.01.00-3	 -- Moderate Impact/Low Probability of Occurrence
-------------------
the package support os rhel7.5.	

		
Defects (15)
- Update code to free intended memory pool.(SCGCQ01488145)
- Memory leak when unloading driver with NVMe flashed SAS35 controller in the system.(SCGCQ01497725)
- Memory leak, after cable pull and push of SAS/SATA drives with DMD set.(SCGCQ01509274)
- Workaround in driver to post 64bit request descriptor to register at offset 0xC0/0xC4 to avoid hitting HW bug.(SCGCQ01514520)
- use scsi_internal_device_block_nowait for RHEL distros greater than RHEL7.3.(SCGCQ01526190)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01473904)
- Driver fails to load post installation..(SCGCQ01458946)
- Fix Timeout value and Reset method used for Target Reset issued on internal command Timeout. (Code Review fix).(SCGCQ01473759)
- Controller fault state 265d while loading latest merged driver for SAS2 card.(SCGCQ01471650)
- Remove logically dead code.(SCGCQ01488142)
- OS crashes when drives are hot plugged while loading driver.(SCGCQ01494556)
- Memory leak seen after using storcli and unloading the driver.(SCGCQ01479414)
- NVMe task management command is not executed as per NVDAT settings.(SCGCQ01524245)
- wrong sizeof argument being passed to sizeof() function..(SCGCQ01484567)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01496368)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01615533 port of SCGCQ01473904)
- mpt3sas: Disable DIX support by default..(SCGCQ01465762 port of SCGCQ01465665)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01504666 port of SCGCQ01496368)
- IO Timeouts observed while running IO and parallel TaskMgmt test with SATA drives	.(SCGCQ01522289 port of SCGCQ01497972)	

EnhancementRequests (8)
- Driver support for OEL 7.4_UEK (4.1.12-94.3.9.el7uek).(SCGCQ01396745)
- Report Package Version from HBA Driver.(SCGCQ01445879)
- Upstream mpt3sas: Fix memory allocation failure test in 'mpt3sas_base_attach()'.(SCGCQ01454958)
- Upstream mpt3sas: Create two versions of scsi_internal_device_unblock().(SCGCQ01447644)
- Upstream mpt3sas: fix format overflow warning.(SCGCQ01454955)
- NVMe Task Management - Controller Reset Support (SCS).(SCGCQ01445901)
- Added support for RHEL7.5 GA (3.10.0-862.el7)..(SCGCQ01749948)
- Upstream mpt3sas: Split scsi_internal_device_block(SCGCQ01447640)

			
version 24.125.01.00 -- Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Marlin B0: OS crashed while running Diag reset with IOs.(SCGCQ01311474)
- Buildkit is modified to install Out of box rpm also in '/lib/modules/4.4.0+2/updates' and also RPM naming convention has been changed to match the inbox driver naming convention.(SCGCQ01318375)
- Disable ASPM for MPI2 controllers.(SCGCQ01329184)  
- RHEL 6.8 32 Bit is hitting kernel panic after loading Phase5.0 PA-3 Driver for IT Ventura Controller.(SCGCQ01418569)
- call-trace observed on RHEL6.x while unloading driver.(SCGCQ01336601)
- Ph4 IT Linux mpt3sas: Observing kernel panic during topology configuration w/ blk-mq enabled.(SCGCQ01351060)
- Ventura Phase5: OS crash while removing the drives connected to the controller.(SCGCQ01386942)
- Linux IT SAS3.5 Phase5 mpt3sas: Observing MCE errors while upgrading the Firmware.(SCGCQ01440053)
- Code Review defect: Don't send sync cache and SSU to FW, when pci_error_recovery or adapter_over_temp is set.(SCGCQ01341910)
- mpt3sas: Avoid sleeping in interrupt context.(SCGCQ01329329)
- Linux IT sas35 Phase5 mpt3sas: FW events sent before diagnostic reset are not getting cleaned up during reset.(SCGCQ01397582)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01473904)
- Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01436811)
- Fixed - Sync cache command failure with hostbyte=DID_NO_CONNECT during driver unload.(SCGCQ01291425)
- Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391926)
- Fix for file system going to read-only mode when controller is resetted.(SCGCQ01315476)
- Fix SAS drives going for Spin Down when module param allow_drive_spindown is set to 3.(SCGCQ01337377)
- Driver Unload command does not exit when connected drives are disconnected while unloading driver.(SCGCQ01403879)
- RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0.(SCGCQ01496368)
- Linux IT Ph14 mpt3sas: Observed kernel panic while performing shutdown operation followed by immediate PCI device hotplug.(SCGCQ01380972 port of SCGCQ01348068)
- Linux IT Ph14 mpt3sas: Observed kernel panic during HBA hot plug operation just before issuing system shutdown operation.(SCGCQ01380973 port of SCGCQ01366025)
- Linux IT Ph14 mpt3sas: Poweroff command fails to shutdown the host post surprise removal of controller.(SCGCQ01380975 port of SCGCQ01352902)
- Linux : Enclosure Handles are not updated for SAS device during diag reset.(SCGCQ01372661 port of SCGCQ01326058)
- Linux IT Ph14 mpt3sas: Added Hot-Plug Surprise removal support on IOCs.(SCGCQ01383826 port of SCGCQ01341334)
- Increase NVMe device queue depth to remove performance bottleneck in the driver.(SCGCQ01316459 port ofSCGCQ01305414)
- Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391990 port of SCGCQ01391926)
- Linux SAS35 Ph3 : By default disable multipath support for SAS3.5 HBA's too.(SCGCQ01316220 port of SCGCQ01301732)
- Linux mpt3sas: Enumeration of drives for OEM specific controller.(SCGCQ01408565 port of SCGCQ01318421)


EnhancementRequests:
- Pre-allocate RDPQ Array at driver boot time.(SCGCQ01297392)
- Ph3 : SLES12 SP3(4.4.73-5) OS support.(SCGCQ01417347)
-0001 - mpt3sas: set default value for cb_idx.(SCGCQ01300828)
-0006 - mpt3sas: always use first reserved smid for ioctl passthrough and second reserved smid for internal scsi io commands.(SCGCQ01300840)
-0007 - mpt3sas: lockless command submission.(SCGCQ01300843)
-0009 - mpt3sas: Enable tag support for all supported kernels.(SCGCQ01300853)
- Added support for XenServer 7.1.(SCGCQ01289850)
- 0005 - mpt3sas: Introduce mpt3sas_get_st_from_smid.(SCGCQ01300838)
- 0008 - mpt3sas: create separate lookup table for NVMe PRP list.(SCGCQ01300851)
- Optimize I/O memory consumption in driver.(SCGCQ01388190)
- Enhanced handling of DMA allocation, If the allocation does not fit within same 4GB.(SCGCQ01388961)
- Added mpt3sas driver support for OEL6.9.(SCGCQ01289003)
- 0003 - mpt3sas: separate out _base_recovery_check.(SCGCQ01300833)
- Reducing the number of times enclosure config page read request sent by driver.(SCGCQ01357382)
- Increase event log buffer to support 24 port HBA's to avoid buffer overflow.(SCGCQ01368517)
- 0004- mpt3sas: open code _scsih_scsi_lookup_get.(SCGCQ01300836)
- Added mpt3sas driver support for RHEL6.9.(SCGCQ01316324)
- Added support for SAS Device Discovery Error Event.(SCGCQ01354911)
- OS Support for RHEL 7.4 (3.10.0-693.el7).(SCGCQ01415978)
- 00010 - mpt3sas: allocate as many chains as needed and remove chain list maintenance overhead.(SCGCQ01300854)
- Ph5 : SLES12 SP3(4.4.73-5) OS support.(SCGCQ01396754)
- 0002 - mpt3sas: use list_splice_init.(SCGCQ01300832)
- Upstream mpt3sas: switch to pci_alloc_irq_vectors.(SCGCQ01367469)

			
			
Version 22.00.01.00 - Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Unable to achieve product targets performance numbers with SAS devices (SCGCQ01175998)
- SATA drive will be in blocked state if diag reset occurs while any ATA Passthrough command is outstanding (SCGCQ01221454)
- Target number for vSES is incremented after host reset (SCGCQ01255996)
- fix hang on ata passthru commands (SCGCQ01255965)

Enhancements:
- Block the drive after recieving any ATA pass-though command for that driver and unblock it after completion of the command (SCGCQ01218960)
- Reduce memory footrpints in kdump kernel (SCGCQ01237163)
- Recognize and act on IO's iopriority info (SCGCQ01237164)
- Added driver support for Dual/multi-path typologies (SCGCQ01237381) 
			
Version 14.00.00.00 - Moderate Impact/Low Probability of Occurrence
------------------
Fixes:
- Fixed an issue where the OS would crash after installing device driver. (SCGCQ01123902)
- Fixed an issue where only 8 MSIX vectors were enabled for SAS3 HBAs on a 32 core machine even though 32 msix vectors could be enabled on the card, since it has RDPQ enabled firmware. (SCGCQ01106942)

Enhancements:
- Updated initial ref tag with correct value for 4K PI drives in kernels less than 3.18. (SCGCQ01066189)
- Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device. (SCGCQ01100134)
- Set maximum transfer length per IO to 4MB for VDs (SCGCQ01072659, SCGCQ01100150 Port of SCGCQ01072631)
 

Version 13.00.02.00 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
- fixed an issue where the initial ref tag was incorrect with 4K sector size drives when PI is enabled for kernel v3.18 and onwards. (SCGCQ01015654)
- Fixed an issue where partial driver message is displayed when active cable power consumption exception occurs.(SCGCQ01025061)
- Merged mpt2sas driver in to mpt3sas driver module. (SCGCQ00955258)

Enhancement
- Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device (SCGCQ01100134)
- Added support for RHEL6.8. (SCGCQ01093683)
- Active cable exception handling in mpt3sas driver (SCGCQ01008402)
- Set maximum transfer length per IO to 4MB for VDs (SCGCQ01100150)
- Fixed issue where OS not discovering all drives in dual node configuration (SCGCQ01026842 PORT of SCGCQ00776162)
- Updated MPI Headers from 2.00.39 to 2.00.42 (SCGCQ01015128)

Version 12.00.00.00 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
- Fixed potential protection fault due to sas device list corruption (SCGCQ00933587)
- Fixed potential protection fault due to fw event list corruption (SCGCQ00933591)
- Fixed memory leak occuring with failed firmware event data (SCGCQ00881682)

Enhancements:
- Make use of additional HighPriorityCredit number of message frames for sending SCSI IO's (SCGCQ00899842)
- Add support for configurable Chain Frame Size. (SCGCQ00933600, Port of SCGCQ00929253)

Version 10.00.02.00-6 - Moderate Impact/Low Probability of Occurrence
------------------
Enhancment:
- Added support for Red Hat 7 Update 1

Fixes:
- Enabled polling for detecting of SMART SATA drives (SCGCQ00791340)

Note: Installed version number is 10.00.02.00

Version 8.00.00.00-1 - Initial release
------------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

LSI Storage Authority Software for windows and linux (For Linux)



LSI Storage Authority Software

Supported controllers:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 730-8i 4GB Cache PCIe 12Gb Adapter  
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-16i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - N2226 SAS/SATA HBA for Lenovo System x (00AE916)
  - N2225 SAS/SATA HBA for Lenovo System x (00AE912)	 
  - N2215 SAS/SATA HBA for Lenovo System x (47C8676)
  - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110)
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210e SAS/SATA Controller for Lenovo System x
  - ServeRAID M5210 SAS/SATA Controller

Support OS:
            - SLES 12/SP1/SP2/SP3, SLES 15.0,SLES 15.1
            - RHEL 7.4/7.5/7.6
			- RHEL 8.0
			- Vmware  ESXi  6.7 U1,U2,U3
            - Vmware  ESXi  6.5 U1,U2,U3
            - Vmware  ESXi  6.0 U1/U2/U3

NOTE TO SERVICE - Reference RETAIN #N/A

007.010.014.000 - Moderate Impact
---------------

Defects (277)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01874775)
 - Issues wrt the linux installer script(SCGCQ01879303)
 - WG: installing LSA on linux 64 bit machine throws an error " ‘/root/Desktop/LaunchLSA.desktop’: No such file or directory"(SCGCQ01897393)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01898255)
 - LSA Event ID 519 shows blank.(SCGCQ01901169)
 - Incorrect icon displayed along with "settings saved" message.(SCGCQ01905838)
 - LSA:Loading More data initially in BGOPS Progress bar in LSA and later Device ID disappears(SCGCQ01937373)
 - PH10 PA LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01940193)
 - WG: No Action Successful notification shown on Drive erase(single Drive)(SCGCQ01941129)
 - LSA 7.9: Mismatch of sector size string between PD table and Group name(SCGCQ01942630)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01949074)
 - LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01949090)
 - Linux binary not working.(SCGCQ01949665)
 - WG: String Changes related to VD operations, Filter blank box turn blue, expand backplane icon can be removed when drives=0(SCGCQ01960486)
 - Fixed: WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963966)
 - SmartCarrier Enclosure type shown as "vSES" in LSA(SCGCQ01965395)
 - : MRSA shows Bay Count as 255 under Enclosure / Backplane properties(SCGCQ01965427)
 - LSA:Add Logical drive Page give option to select"Cached IO" for an LD and Error message not Branding compliant(SCGCQ01965445)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01966275)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01966687)
 - WG:GUI issues:50x Html file,View server profile with no enclosure,View More of System messages, Restore Settings notification(SCGCQ01968404)
 - WG: GUI issues Pertaining to alignment of notification on scroll of LSA page	(SCGCQ01968457)
 - WG: LSA fails with the empty status description on trying to change the personality in presence of snapdump(SCGCQ01969570)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ01970007)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ01970452)
 - Port information missing under Enclosures List.(SCGCQ01972260)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01972673)
 - Reference to BBU in Server profile page(SCGCQ01976904)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ01976926)
 - Logical drives are listed in the GUI when all the drives are pulled out	(SCGCQ01976929)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01977769)
 - Fixed: Added check for missing drive case(SCGCQ01978914)
 - Fixed: LSA stops responding after creating Vd with 4k Drives(SCGCQ01978965)
 - VD/HotSpare reference in Clear Configuration Confirmation popup-Regression(SCGCQ01979076)
 - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01979137)
 - Error code is not displayed for DG add VD operation failure(SCGCQ01988209)
 - Modify array option available for Degraded R5 , Blank screen followed "0 drives" on removing drives(SCGCQ01988400)
 - Fixed: update Validation Check codes for the image file(SCGCQ01989969)
 - Aero A0: RWC3 does not show version of Selected Firmware Version for updating(SCGCQ01989970)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL(SCGCQ01993099)
 - Fixed: OS name for localhost is inconsistent with the Osname populated when discovered via slp(SCGCQ01994459)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ01998245)
 - Fix: WG: Intance validation for Controller Get fails : MR Ventura(SCGCQ01998299)
 - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998305)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02006229)
 - WG: Switching between view server profile and settings page would not load the view server profile(SCGCQ02007150)
 - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure (SCGCQ02009718)
 - LSA 7.9: Action successful notification is not seen for encrypting the DG(SCGCQ02010670)
 - LSA: Mismatch in Unconfigured Good string(SCGCQ02016646)
 - LSA: Patrol Read string display issue(SCGCQ02016879)
 - WG : LSA 7.9 Status code for Drive security disable message is showing same for StatusLevel 0 and 1(SCGCQ02018083)
 - Difference in naming of Array during Array creation(SCGCQ02019200)
 - WG: GUI issues pertaining to star/stop patrol read & remote discovery page(SCGCQ02019555)
 - Back-plane information showing as blank in server profile page.(SCGCQ02019592)
 - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02021372)
 - LSA : Updating FW pkg version is not shown during FW upgrade/downgrade.(SCGCQ02023284)
 - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02023407)
 - LSA 7.10:Unsupported drives are displayed as UG under server profile page.(SCGCQ02030950)
 - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further	(SCGCQ02032031)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ02032824)
 - Error message displayed for entering wrong password to unlock foreign VD/PD should be updated.(SCGCQ02034263)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02034466)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02035158)
 - WG: mouse hover icon missing for the connected device property column in manage link speed pane(SCGCQ02035223)
 - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02035226)
 - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02035317)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02035322)
 - WG: Selected element count does not get updated after auto page refresh when VD expand operation is performed(SCGCQ02036089)
 -(SCGCQ02036091)
 - WG: wrong notification shown on trying to unlock a foreign FDE drive with wrong passphrase and then with correct passphrase(SCGCQ02036701)
 - Aero DBU PA1:LSA-Issue pertaining to add hotspare while creating Vd(SCGCQ02038235)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02038386)
 - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW(SCGCQ02040516)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02040739)
 - Shenandoah_MRSA: Warning message improvement when tried to delete LD formatted with File System(SCGCQ02042555)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware	(SCGCQ02043781)
 - WG : LSA 7.10 Keyboard short cut keys are NOT there for Different pages of LSA Installation pages(SCGCQ02045646)
 - Fixed: OCR should trigger update of dual image components(SCGCQ02048856)
 - WG: Issues pertianing to set snapdump properties page--> enable disable snapdump and changing cache offload limit.(SCGCQ02048906)
 - WG: Incomplete foreign VD is seen when Clear foreign config is performed, incorrect status code on rescan after clear foreign(SCGCQ02049476)
 - WG:Securing JBOD option gets disabled if from list of JBODs selected even if one is unselected(SCGCQ02049479)
 - LSA displays one of the PD's is missing as part of foreign config even if all the PDs are connected(SCGCQ02049511)
 - WG: Few of VD and PD operations will not be usable in LSA without zooming out ((SCGCQ02049819(SCGCQ02049819)
 - WG: in presence of missing drive the select all and element count does not work properly in span drive tab(SCGCQ02050441)
 - WG 7.10:Advance controller info does not show whether energy pack is connected or not(SCGCQ02050502)
 - WG 7.10:Number of foreign config count is not updated if clear drive operation performed on a foreign pd.(SCGCQ02050579)
 - WG 7.10:Migration from r0 (31 pds(SCGCQ02050857)
 - Error and Warnings thrown while install/upgrade MRSA on SLES15(SCGCQ02053038)
 - WG: LSA notifications GUI issues & Other Hardware user info on expanding enclosure info, LSA conf file, Message_en file(SCGCQ02053156)
 - WG: UI Elements alignment for DG actions and Fixed action menu with lower resolution(SCGCQ02053167)
 - LSA Firmware package version shown as version in controller action page.(SCGCQ02053748)
 - LSA Simple configuration from main page shows blank when JBOD are present.(SCGCQ02053891)
 - Fixed: Last Vd size was not being checked for alignment(SCGCQ02058284)
 - Fixed: timestamp inside compressed file is not appropriate(SCGCQ02058485)
 - LSA capacity column sort not working in other Hardware Tab.(SCGCQ02058597)
 - Default Logical Drive name is showing as "VDName**" , while creating Logical drive through Simple Configuration(SCGCQ02062623)
 - WG: Element count not updated on selecting foreign drives and sorting Foreign drive list, it continues to show PD operations(SCGCQ02063630)
 - MRSA: LD Name discrepancy for 1 LD and 2 LDs without LD_Name during Array creation(SCGCQ02067043)
 - In presence of NVME drives, applying and Clearing filter and then sorting the drives results in incorrect PD list(SCGCQ02069473)
 -(SCGCQ02069524)
 -(SCGCQ02074686)
 - WG_7.10: Spacing alignments to be done in the VD setting page during the VD creation	(SCGCQ02076790)
 - WG_7.10: While consistency check is in progress on VD, if we click pause progress bar is misaligned(SCGCQ02076792)
 - Fixed: check in place to create nvmeOnly disk group during migration	(SCGCQ02076800)
 - WG: FDE foreign config after performing instant secure erase on one of the drive shows incomplete in LSA(SCGCQ02080536)
 - WG_7.10: Spell check and spacing issues in Latest LSA (007.010.003.000)(SCGCQ02081258)
 - "Drive Group list is empty" error message seen when multiple drives are assigned as DHSP to a VD, issue per(SCGCQ02081264)
 - Silent installation is NOT working on Ubuntu 16.04(SCGCQ02082129)
 - Download support Log not working.(SCGCQ02082514)
 - Aero (DBU PA3(SCGCQ02082524)
 - DG number displayed outside the box(SCGCQ02089434)
 - Aero DBU PA2(LSA	(SCGCQ02091088)
 - WG: selected element count shown wrong on selecting PD list(including mising(SCGCQ02095469)
 - Fixed: missing pd info was leading to population of wrong candidate pds(SCGCQ02095494)
 - WG: LSA Lists drives of a type even if less for a raid level creation if user selects raid level from compare select(SCGCQ02096215)
 - Fixed: Changed build files to build client for ESXi(SCGCQ02096396)
 - WG: LSA snapdump files generated are only of 32 kb even if the actual snapdump file size is much higher than that(SCGCQ02100467)
 - WG: Filter options does not list NVMe drives in PD list of controller console page(SCGCQ02107270)
 - WG: extracting snapdump file using 7zip, user is notified regarding header error in etty file, spacingissue of text in OFU(SCGCQ02108538)
 - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02108817)
 - Fix API changes done for NVMe readiness(SCGCQ02142981)
 - Add NVMe width comments to mr.h(SCGCQ02146846)
 - Fixed: changed the max drive value of R1 for cachecade drives(SCGCQ02169419)
 - LSA - AWB option is coming for CC VD with Rambler card while creating CC VD(SCGCQ02169687)
 - LSA Cache update for PD insert for it ctrls(SCGCQ02191080)
 - WG: LSA does not display the correct VD creation time in VD get URI response(SCGCQ01889478)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01902964)
 - LSA 7.9: Display error for "OS name" when expand/minimize is performed.(SCGCQ01904365)
 - Fixed: Configuration service changed to accomadate allomixinSSD bit(SCGCQ01925161)
 -(SCGCQ01927978)
 - LSA 7.9:Changing server parameter in Configfile.json file to 2 , scheduler does not kick inn and LSA crashes(SCGCQ01930410)
 - LSA 7.9 PA:failure messange with description success on enabling/disabling scsi unmap feature.(SCGCQ01936667)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01940852)
 - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01942985)
 - Fixed: Foreign drives are not considered as configured & which leads to a mismatch in JBODconversion count during VD creation(SCGCQ01943388)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01943617)
 - LSA 7.9: Mismatch in "Unconfigured drives and replace drive" count.(SCGCQ01944392)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01952143)
 - LSA 7.9:Unable to start instanst secure erase operation on multiple Pds when scheduler is on.(SCGCQ01955160)
 - WG: Issues pertaining to Settings page(SCGCQ01956683)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ01957078)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ01960300)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01962216)
 - LSA 7.9 alpha :The error code 69636 is seen without view more option when pause on CC operation is performed twice(SCGCQ01971576)
 - WG:LSA displays the snapdump count in hex value, GUI issues in snapdump pane(SCGCQ01973964)
 - MRSA event for Drive erase abort is coming blank in "View Event log" for event ID 421(SCGCQ01976894)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ01978171)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ01979083)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ01979598)
 - LSA : Port details are missing in drive removal/insert events.(SCGCQ01979793)
 - Fixed: missing Event description for new events was pausing LSA(SCGCQ01980570)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ01983080)
 - MRSA : Copyback progress details is not proper in BGI progress tab.(SCGCQ01996577)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02003711)
 - WG: GUI issues : Drive Security text on Hover, system messages clickable text, bell button notification(SCGCQ02006538)
 - “404 Not Found” seen on upgrading Snap4 GA to OEM Builds and later removing and installing new build(SCGCQ02016688)
 - LSA 7.10:Covert button of the Jbod table is activated and flickers when more than eligible count pds are selected.(SCGCQ02024507)
 - WG: No VD or PD details shown for progress operation in VMware(SCGCQ02028695)
 - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02031517)
 - WG : LSA Cache Offload Limit value change was not changing without manual refresh(SCGCQ02043843)
 - WG: LSA view event log list the Portmap as '0' instead of '08' for scsiType=0 (ie PDs)(SCGCQ02045715)
 - LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups.(SCGCQ02045735)
 - WG: LSA does not show the details of the current profile when there is only one profile supported(SCGCQ02045758)
 - WG: System LSA monitor event logs has junk characters(SCGCQ02049034)
 - WG: Path information for PD reset event is empty in event logs (event id : 268(SCGCQ02049577)
 - LSA: Domain login for administrator fails with "Error code:49 Invalid credentials".(SCGCQ02049807)
 - WG 7.10:if VD count is above limit and VD capacity is changed, LSA allows user to create VD which fails(SCGCQ02050533)
 - LSA Simple Configuration for R6 fails with error.(SCGCQ02053837)
 - LSA service crashing in ubuntu(SCGCQ02061370)
 - Linux Build is always picking old library(SCGCQ02061380)
 - Aero DBU PA2(LSA	(SCGCQ02065672)
 - Incorrect number of slots is displayed for UBM U.2X2 Vses Backplane in LSA.(SCGCQ02069871)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02070841)
 - Aero DBU PA2(LSA	(SCGCQ02074776)
 - WG_7.10:In the Error code:118 description, Spacing alignments to be done.(SCGCQ02076794)
 - WG_7.10: SAS address is shown for PCIe (NVME	(SCGCQ02076924)
 - Wide port info is not displayed for physical drive under connector name for Backplane attached drives.(SCGCQ02076933)
 - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02078435)
 - LSA: Read_only_access group users are given administrator privileges(SCGCQ02078614)
 - WG: User is notified to select the Drive group even if VD and PD tab of the DG is clicked(SCGCQ02080553)
 - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02081038)
 - During LSA upgrade some of the old build files are not removed in Ubuntu	(SCGCQ02082116)
 - WG 7.10: wrong health status of a gateway server seen when discovered from same gateway server.(SCGCQ02084545)
 - WG:LSA Direct agent or LWM installation from main package creates desktop shorcut in linux(SCGCQ02084636)
 - WG 7.10:Scheduler wrapper does not kick in for enable security operation(SCGCQ02085660)
 - Fixed: FDE and Opal mixing shouldn't be allowed(SCGCQ02086784)
 - Migration from R1 Vd(4 drives)(SCGCQ02087362)
 - Element action pane border incomplete during single PD selection, user name/password blue box alignment(SCGCQ02091191)
 - Issue pertaining to failure notification(SCGCQ02095408)
 - Fixed: FW upgrade issues with Aero FW files(SCGCQ02097971)
 - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02108807)
 - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119031)
 - Fixed: Cachecade VD creation diaglog doesnt populate Raid levels	(SCGCQ02142026)
 - "Remove drives" option should not come if user is doing RLM from R6 with 3 drives to R5(SCGCQ02184393)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01512320)
 - LSA needs to Handle when controller is in safe Mode	(SCGCQ01838234)
 - MRSA : MRSA shows the logout option in drop down menu .(SCGCQ01902913)
 - LSA 7.9: Unable to enter password while adding mail server authentication.(SCGCQ01933819)
 - LSA 7.9 :Status error description for schedular operation is not mapped to the proper device ID.(SCGCQ01940978)
 - WG: NO PD info is shown for foreign configuration(SCGCQ01942159)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ01942452)
 - WG:Remove icon for manually added server not shown in manage server page, Signin should be disabled when login in progress(SCGCQ01960469)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01961390)
 - LSA 7.9 alpha: Error code 69642 is seen when disable/enable unmap operation is performed on Unmap VD.(SCGCQ01963097)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01969806)
 - WG: All the events to Vmware are coming as information(SCGCQ01973905)
 - LSA 7.9: Incorrect critical message displayed for Offline PD.(SCGCQ01979150)
 - Fixed: Updated curl library for Linux OS	(SCGCQ01979794)
 - LSA 7.9: Re-scan button is disabled after GHS import.(SCGCQ01982953)
 - LSA 7.9:FDE HDDs are assigned as DHSP for an encrypted OPAL VD(SCGCQ01982973)
 - Status reports as failed although firmware is updated successfully(SCGCQ01983031)
 - MR 7.9 PA: LSA Win: 7.9_PA-007.009.007.000 Fails to display JBOD, StorCLI works fine(SCGCQ01994803)
 - LSA does not show failure or success notification when clear configuration is performed.(SCGCQ01996512)
 - WG: Instance Validation failed for Event history GET	(SCGCQ01998296)
 - LSA - Selected firmware version displayed as blank during update firmware(SCGCQ02034485)
 - LSA: Administrators User group is given Read only privileges after adding Users to Administrators group.(SCGCQ02048915)
 -(SCGCQ02048923)
 - Client changes for review-30 schema compliance(SCGCQ02062850)
 - Aero DBU PA2(LSA	(SCGCQ02065575)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070840)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02084515)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02094537)
 - GUI css issues with update firmware panel and snapdump actions(SCGCQ02094845)
 - Spacing issues seen while converting a drive from JBOD to UG	(SCGCQ02095422)
 - WG:Enclosure ID and Device ID display inconsistency in SS page and CC page, Configure options in SS page alignment issues(SCGCQ02095855)
 - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02103116)
 - Capacity sorting is not working in presence of TB drive in the PD list of VD creation.(SCGCQ02107449)
 - Snap dump trigger time format ends with Z character.(SCGCQ02184362)
 - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01880101)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ01880184)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ01888233)
 - LSA 7.8: Incorrect VD capacity size displayed during VD creation(SCGCQ01897176)
 - LSA 7.9: Mismatch in the alignment of server list.(SCGCQ01904368)
 - Update firmware version link not clickable in Server Landing Page(SCGCQ01905815)
 - After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01927915)
 - LSA Client: In Remote Discovery page, "servers" call is being made twice(SCGCQ01932106)
 - Incorrect tab listener in login page.(SCGCQ01932725)
 - LSA 7.9: "Personality management" page do not close automatically after launch of "Schedule consistency check" page.(SCGCQ01933812)
 - Fixed: clear and generate snap dump feature should not be displayed if snap dump is disabled(SCGCQ01936663)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01937263)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01951802)
 - WG:GUI issues:Controller health text,system message bar,download log, scheduler operation failure & JBOD to UG notifications(SCGCQ01968459)
 - Fixed: LSA 7.9:In presence of 32 GHSPs, advance configuration option is leading to configurable page on iMR card(SCGCQ01969524)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ01969611)
 - LSA_7.9: Status code and description are not clear during Unconfigured Bad to Unconfigured Good operation.(SCGCQ01972681)
 - WG: JBOD to UG conversion popup does not show error notification in case there is an OS drive, fails with 400ok though(SCGCQ01973688)
 - WG: Enabling and disabling the alarm multiple times shows error message without error code number(SCGCQ01973701)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01974131)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ01993611)
 - LSA locate time inaccurate(SCGCQ02038270)
 - Aero DBU PA2(LSA	(SCGCQ02065617)
 - No response observed when tried to import Foreign LDs which results is reaching MAX LDs(SCGCQ02082982)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102427)
 - 7.10-LSA: Event ID 457 description ends junk character.(SCGCQ02184221)
 -	(SCGCQ01878801)
 - LSA 7.9: Incorrect value accepted during PD locate and wrong Icon displayed in IE when compared to Chrome.(SCGCQ01901766)
 - LSA server profile shows IT-IR storlib versions.	(SCGCQ01901771)
 - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ01901773)
 - LSA 7.9: Server search list no more displayed if the user press enter or move the cursor.(SCGCQ01905850)
 - PH10 PA - LSA - Logout option not presented when drop down arrow is clicked(SCGCQ01934763)
 - WG: Status code description is not proper(SCGCQ01942172)
 - LSA 7.9: After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01949787)
 - LSA 7.9 alpha:LSA Status code enhancements - Individual operations related issues(SCGCQ01961403)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ01968407)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ01973705)
 - LSA PR (SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562)
 - WG_7.10: Enclosure location shows blank for the NVME drives	(SCGCQ02076920)
 - LSA - AWB option is coming for CC VD with Rambler card when user try to modify VD properties if CC VD goes offline/degraded(SCGCQ02184389)
 - WG: Table formatting is not proper in controller console page(SCGCQ01875668)
 - Fixed: Adding more than 1 vd on a hole & adding more than 1 vds on existing DG fails in LSA(SCGCQ01940161)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01944435)
 - Fixed: Download DA/SA server report when downloaded remotely from Gateway(SCGCQ01969625)
 - MRSA: Enclosure count updated wrong in Server profile page(SCGCQ01976923)
 - For 7.10 LSA with max VD configuration, with foreign configuration present LSA unable to import or reject or proper message should displayed. Can you please look into this issue.(SCGCQ02184326)
 - LSA 7.9: Select and un-select button does not work after minimizing the tab(SCGCQ01978952)
 - Fixed: Blank page shown on trying to login 2nd time VMware using Manage server page(SCGCQ02035380)
 - LSA : Getting wrong data about max number of PD support for R6 while doing RLM(SCGCQ02184391)
 - SCGCQ01134787: GUI’s are required to be localized for the following languages: English, French, Italian, German, Spanish, and Japanese(SCGCQ01840448 port of SCGCQ01134787)
 - Security Standalone requirements for LSA Server code changes	(SCGCQ01854924 port of SCGCQ01399720)
 - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01857649 port of SCGCQ01598200)
 -	(SCGCQ01868298 port of SCGCQ01564366)
 - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01869716 port of SCGCQ01598139)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01962269 port of SCGCQ01898255)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963971 port of SCGCQ01512320)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390)
 - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01971208 port of SCGCQ01942985)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01972651 port of SCGCQ01966687)
 - Fixed: missing Event description for new events was pausing LSA(SCGCQ01991449 port of SCGCQ01980570)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02000919 port of SCGCQ01929667)
 - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02002118 port of SCGCQ01993697)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007219 port of SCGCQ01929667)
 - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02015378 port of SCGCQ01993697)
 - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure "(SCGCQ02016686 port of SCGCQ02009718)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02030825 port of SCGCQ02006229)
 - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02031020 port of SCGCQ02023407)
 - LSA Client : Trigger and Download Snap Dump from application	(SCGCQ02032043 port of SCGCQ01917087)
 - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02032206 port of SCGCQ02021372)
 - WG: No Action Successful notification shown on Drive erase(single Drive(SCGCQ02032617 port of SCGCQ01941129)
 -(SCGCQ02034407 port of SCGCQ02030621)
 -(SCGCQ02034409 port of SCGCQ02030621)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035246 port of SCGCQ02034466)
 - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02036726 port of SCGCQ02035226)
 - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02042291 port of SCGCQ02006229)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611)
 - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270)
 - LSA locate time inaccurate(SCGCQ02043619 port of SCGCQ02038270)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ02044809 port of SCGCQ01973705)
 - Issues wrt the linux installer script	(SCGCQ02044832 port of SCGCQ01879303)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078)
 - No help option available for Megacell option whenever it calls for “Needs Attention” in LSA(SCGCQ02050529 port of SCGCQ02022983)
 - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW	(SCGCQ02053882 port of SCGCQ02040516)
 - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ02055506 port of SCGCQ01901773)
 -(SCGCQ02055834 port of SCGCQ01878801)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055865 port of SCGCQ02035322)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02057603 port of SCGCQ02003711)
 - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ02064849 port of SCGCQ01984624)
 - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067442 port of SCGCQ02045048)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070858 port of SCGCQ02070840)
 - LSA: Read_only_access group users are given administrator privileges(SCGCQ02080158 port of SCGCQ02078614)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02087354 port of SCGCQ02070841)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02093538 port of SCGCQ02070841)
 - Fixed: Allowed Simple config parameters are not displayed(SCGCQ02094990 port of SCGCQ02076799)
 - LSA is not showing PD Connector information properly with passive backaplane	(SCGCQ02096769 port of SCGCQ02096766)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102495 port of SCGCQ02102427)
 - Application Crash when tried to create a LD with 15 character length	(SCGCQ02113222 port of SCGCQ02112041)
 - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119286 port of SCGCQ02119031)
 - Application Crash when tried to create an LD with 15 character length(SCGCQ02121748 port of SCGCQ02111930)
 - WG 7.11: Simple configuration fails when multiple vds are created.(SCGCQ02125582 port of SCGCQ02125538)
 - Configuration options is not getting updated when we change the personality(SCGCQ02154818 port of SCGCQ02124500)
 - Only 1 drive is displayed although more than 1 drive has opted for Dedicated drive(SCGCQ02154840 port of SCGCQ02113971)
 - Aero DBU PA5(LSA): Secure jbod option is not shown for the FDE capable jbod drive in LSA(SCGCQ02162725 port of SCGCQ02149233)
 - LSA service/Nginx service is stopping after few hours and WebGUI is not responding in RHEL 8.0 OS(SCGCQ02172192 port of SCGCQ02151342)
 - LSA Aero IT: LSA installation with "start from now" option is throwing error code:9098 in event logs.(SCGCQ02172199 port of SCGCQ02121896)
 - Event ID 610 and 611 are empty(SCGCQ02172244 port of SCGCQ02166100)
 - Generic LSA w/MRSA backend (Snap 3(SCGCQ01818695 port of SCGCQ01532391)
 - IML event customization (Mesa Verde(SCGCQ01837799 port of SCGCQ01625911)
 - Dual Firmware Image Support on Controller Flash for Recovery	(SCGCQ01847635 port of SCGCQ01320454)
 - LSA : Dqueue logs need to be fetched in smaller chunks by the applications(SCGCQ01860906 port of SCGCQ01571368)
 - SSD WEAR GAUGE Support(SCGCQ01891668 port of SCGCQ01890543)
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915862 port of SCGCQ01905192)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368)
 - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon	(SCGCQ01990298 port of SCGCQ01856350)
 - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01990346 port of SCGCQ01829895)
 - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon	(SCGCQ02001873 port of SCGCQ01856350)
 - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further	(SCGCQ02034499 port of SCGCQ02032031)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL)(SCGCQ02042097 port of SCGCQ01993099)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300)
 -(SCGCQ02043859 port of SCGCQ01927978)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055880 port of SCGCQ02035322)
 - Status reports as failed although firmware is updated successfully(SCGCQ02058472 port of SCGCQ01983031)
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ02081267 port of SCGCQ01838943)
 - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02084746 port of SCGCQ02078435)
 - NVMe Drive interface type should be shown as "NVMe" instead of "PCIe"(SCGCQ02100198 port of SCGCQ02096718)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427)
 - Fixed: Snap dump file(SCGCQ02105149 port of SCGCQ02080184)
 - WG 7.11:Jbod Locked foreign config details are empty under foriegn configuration operation.(SCGCQ02112529 port of SCGCQ02112203)
 - WG: LSA incorrectly notifies "Incomplete or Non-Importable foreign configuration found" instead of max supported configuratio(SCGCQ02162724 port of SCGCQ02149353)
 - WG: LSA shows the same connector for both backplane and enclosure in properties pane(SCGCQ02179358 port of SCGCQ02167855)
 - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01869701 port of SCGCQ01246226)
 - Support newly added Sanitize event for cache update.(SCGCQ01869717 port of SCGCQ01740786)
 - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01918643 port of SCGCQ01880101)
 -(SCGCQ01925516 port of SCGCQ01714322)
 - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074)
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume(SCGCQ01970440 port of SCGCQ01752969)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01974074 port of SCGCQ01971368)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466)
 - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067299 port of SCGCQ02044922)
 - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02082904 port of SCGCQ02081038)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427)
 - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02116793 port of SCGCQ02108807)
 - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02118270 port of SCGCQ02108817)
 -	(SCGCQ02154813 port of SCGCQ02142063)
 - Fixed: parity disk count was missing in algorithm to calculate minimum VD(SCGCQ02154869 port of SCGCQ02139246)
 - WG: LSA does not update on Clearing the config from server summary page in presence of degraded config(SCGCQ02160137 port of SCGCQ02154073)
 - LSA - upgrade installshield(SCGCQ02164387 port of SCGCQ02087375)
 - Download Server Report – change this to Download Support Log and Remove Download Diagnostics	(SCGCQ01824401 port of SCGCQ01388152)
 - LSA No Login (HPE Snap 3 SOW	(SCGCQ01840451 port of SCGCQ01512600)
 - Sanitize Support (HPE SNAP 3	(SCGCQ01857424 port of SCGCQ01564367)
 - IML event customization (Mesa Verde(SCGCQ01868281 port of SCGCQ01625911)
 - LSA is allowing to delete OS VD.	(SCGCQ01923557 port of SCGCQ01873420)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01942179 port of SCGCQ01937406)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive	(SCGCQ01962278 port of SCGCQ01952143)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967919 port of SCGCQ01918692)
 - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998976 port of SCGCQ01998305)
 - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007218 port of SCGCQ01929667)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02053863 port of SCGCQ02035322)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02062148 port of SCGCQ02035158)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02093240 port of SCGCQ02070841)
 - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02105326 port of SCGCQ02103116)
 - RHEL8- LSA reports warnings during Service restart after reboots, remote discovery page does not list any server other server(SCGCQ02159794 port of SCGCQ02144606)
 - : Support PCI Slot and Serial Number in(SCGCQ01822600 port of SCGCQ01351434)
 - MRSA:Default strip size should be 64KB for SSD(SCGCQ01825959 port of SCGCQ01406706)
 - Change the word data protection to Data Integrity Field(SCGCQ01839302 port of SCGCQ01827434)
 - Expander support for LSA(SCGCQ01839611 port of SCGCQ01372657)
 - (SCGCQ01681996: Copy back option should not prompt for already copyback progress PD.(SCGCQ01840438 port of SCGCQ01681996)
 - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01847392 port of SCGCQ01134783)
 -(SCGCQ01943786 port of SCGCQ01932181)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx	(SCGCQ02000918 port of SCGCQ01929667)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02012079 port of SCGCQ02000446)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427)
 - LSA is using old PDL for send Feedback option(SCGCQ02133579 port of SCGCQ02133392)
 - WG: Making an offline drive of a DG to online does not work in controller health pane, no POST call for same is initiated(SCGCQ02144596 port of SCGCQ02139321)
 - (SCGCQ01399721: Hercules :HPE: Security Standalone requirements for LSA Linux 32/64 bit Installer changes(SCGCQ01827380 port of SCGCQ01399721)
 - Support PCI Slot and Serial Number in Mesa Verde	(SCGCQ01839058 port of SCGCQ01349491)
 - Capacity Unit Changes for VD in LSA Client from GB to GIB(SCGCQ01859426 port of SCGCQ01708968)
 -	(SCGCQ01864209 port of SCGCQ01763927)
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904366 port of SCGCQ01901758)
 - IML event customization (Mesa Verde(SCGCQ01837623 port of SCGCQ01601601)
 - Megacell Status Support (SNAP3(SCGCQ01868328 port of SCGCQ01566234)
 -	(SCGCQ01869156 port of SCGCQ01320455) -
 - WG 7.11:Enable scsi unmap checkbox at advance config page is grayed out when enable/disable operation is performed.(SCGCQ02154812 port of SCGCQ02118865)
 - Security Standalone requirements for LSA Server code changes(SCGCQ01854929 port of SCGCQ01399722)
 - Expander support for LSA	(SCGCQ01855600 port of SCGCQ01376077)
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01869616 port of SCGCQ01849749)
 - Capacity Unit Changes for VD in LSA Server(SCGCQ01869745 port of SCGCQ01708881)
	
EnhancementRequests (35)
 - Enhance Status Code and Status description(SCGCQ01825960)
 - LSA Internal Status code and Description(SCGCQ01850884)
 -(SCGCQ01949651)
 - Branding tool and Health (OS eventing(SCGCQ01960398)
 - Ubuntu LSA support(SCGCQ02042072)
 - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048)
 - Branding tool and Health (OS eventing(SCGCQ02045972)
 - API changes for NVMe speed and width changes(SCGCQ02053667)
 - API changes for linkconfig interface	(SCGCQ02053671)
 - Change the parent directory name to "HPEMRSA" in the windows(SCGCQ02055912)
 - Implement Changes for LSA Light weight agent On ESXi 64 bit Platform(SCGCQ02066385)
 - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252)
 - API changes for a better presentation of Atlas to tools(SCGCQ02149380)
 - Snap Dump ClearAll Method logging event(SCGCQ02157359)
 -(SCGCQ02162699)
 - Create an event for DDF config clear failed event.(SCGCQ02173513)
 - WG: LSA "Feedback" UI enhancements(SCGCQ01401503)
 - LSA Client : Trigger and Download Snap Dump from application(SCGCQ01917087)
 - Implemented: Allow user to generate snap-dump in firmware and download it(SCGCQ01917294)
 - Client: Ubuntu LSA support(SCGCQ02042121)
 - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02044922)
 - 64 Bit SLIR3 library to Support for VMWARE ESXi 6.7+	(SCGCQ02048704)
 - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334)
 - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048)
 - Add new topology device type for Atlas switch(SCGCQ02150637)
 - LSA need to show complete Serial Number and Model Name for NVMe drives(SCGCQ01920105)
 - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ01984624)
 - SSD WEAR GAUGE Support(SCGCQ01890543)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ01929667)
 - 64 Bit SLIT library Support for VMWARE ESXi 6.7+	(SCGCQ02019271)
 - LSA: SSD WEAR GAUGE Support(SCGCQ01890612)
 - MRSA One Click Support Client support(SCGCQ01949650)
 - LSA Server: Scheduler changes to fit with latest LSA status code(SCGCQ01857843)
 - Enhance Status Code and Status description(SCGCQ01868342)
 - LSA Server: Aero FW simplification - Changes for disable least latency mode(SCGCQ01944689)

005.047.000.000 - Moderate Impact
---------------

Defects:
 -WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01680714)
 -Fixed: nvme is allowed to mix with sas /sata.(SCGCQ01762948)
 -WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile.(SCGCQ01747490)
 -WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline(SCGCQ01752969)
 -WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod.(SCGCQ01763742)
 -WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection).(SCGCQ01764794)
 -WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01737550)
 -LSA locate time inaccurate.(SCGCQ02038270)
 -LSA PR SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562)
 -LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups..(SCGCQ02045735)
 -LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab.(SCGCQ02078435)
 -LSA: Read_only_access group users are given administrator privileges.(SCGCQ02078614)
 -RWC3 Windows Readme contains IR3 controllers under supported controllers list.(SCGCQ02081038)
 -Fixed: R00 max pd limit is changed to be aligned with fw requirement.(SCGCQ02108807)
 -LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1.(SCGCQ02108817)
 -LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info..(SCGCQ02119031)
 - LSA installation failed on SLES15.(SCGCQ01784699 port of SCGCQ01760620)
 - LSA needs proper message for max config import.(SCGCQ01789100 port of SCGCQ01763411)
 - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01789156 port of SCGCQ01731931)
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716625 port of SCGCQ01716622)
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup.(SCGCQ01810649 port of SCGCQ01803341)
 - MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813086 port of SCGCQ01813078)
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01816649 port of SCGCQ01686080)
 - MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01816428 port of SCGCQ01641760)
 - LSA needs proper message for max config import.(SCGCQ01813925 port of SCGCQ01764977)
 - C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01828830 port of SCGCQ01321211)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events.(SCGCQ01826237 port of SCGCQ01761830)
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828)
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01851980 port of SCGCQ01851906)
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA.(SCGCQ01851919 port of SCGCQ01841280)
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681)
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS..(SCGCQ01880123 port of SCGCQ01876091)
 - handling the session management.(SCGCQ01892868 port of SCGCQ01829897)
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01891168 port of SCGCQ01889547)
 - Handling the set text mechanism in client.(SCGCQ01886532 port of SCGCQ01850387)
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01897181 port of SCGCQ01841473)
 - Fixed: Crash when pressing back button after logout.(SCGCQ01892905 port of SCGCQ01865309)
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01897266 port of SCGCQ01818960)
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943)
 - fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01901774 port of SCGCQ01866289)
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01898263 port of SCGCQ01802344)
 - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01901754 port of SCGCQ01827404)
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01897144 port of SCGCQ01817275)
 - Update the Windows Server 2019 OS name in LSA.(SCGCQ01897178 port of SCGCQ01866322)
 - Remove un printable characters from LSA log.(SCGCQ01901769 port of SCGCQ01901760)
 - Server: LSA GUI Not Updating Security Key Info.(SCGCQ01897099 port of SCGCQ01761801)
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle.(SCGCQ01915861 port of SCGCQ01905192)
 - [CISCO]LSA shows previously set security key (M3g@raid) during importing secured foreign config JBOD (TCG Enterprise SED).(SCGCQ01921581 port of SCGCQ01878346)
 - LSA fails to start initialization on EPD if it has DDF.(SCGCQ01921583 port of SCGCQ01849522)
 - (SCGCQ01921684 port of SCGCQ01841361)
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event.(SCGCQ01921836 port of SCGCQ01876230)
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives..(SCGCQ01904075 port of SCGCQ01893304)
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade..(SCGCQ01904345 port of SCGCQ01901758)
 - .(SCGCQ01920699 port of SCGCQ01808698)
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01921839 port of SCGCQ01829669)
 - (SCGCQ01921842 port of SCGCQ01803373SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS)
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249)
 - .(SCGCQ01920924 port of SCGCQ01818618)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01921819 port of SCGCQ01856350)
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,.(SCGCQ01915812 port of SCGCQ01906914)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895)
 - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01829895)
 - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01865420)
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350)
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives DESCRIPTION OF ISSUE(SCGCQ01921580 port of SCGCQ01823858)
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445)
 -WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674 )
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command.(SCGCQ01930623 port of SCGCQ01926876)
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01961510 port of SCGCQ01889547)
 - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01980553 port of SCGCQ01979137)
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768)
 - Optimize the operation areas of UI to add “on demand” call and increase the performance(SCGCQ01792860 port of SCGCQ01746630)
 - Add sorter on individual panel's header(SCGCQ01792967 port of SCGCQ01614993)
 - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793020 port of SCGCQ01761197)
 - LSA Server: Enhance view server profile(SCGCQ01793119 port of SCGCQ01613889)
 - Add a way to move from Server / Controller dashboard to Login / Remote Server Discovery Page.(SCGCQ01793314 port of SCGCQ01760616)
 - LSA Client : GUI User Interface to display snap dump details and download snap dump.(SCGCQ01788693 port of SCGCQ01788622)
 -GUI Performance improvement by reducing the GUI binary size.(SCGCQ01791174 port of SCGCQ01484572)
 - WG: Clicking on help links anywhere in LSA page for VMware leads to "404-not found" page.(SCGCQ01791205 port of SCGCQ01594101)
 - LSA Server: Client Logging(SCGCQ01793221 port of SCGCQ01745790)
 - Enhance Action menu of individual and group element(SCGCQ01793250 port of SCGCQ01606850)-
 - Add Select All / Un-Select All option to dashboard tables.(SCGCQ01793004 port of SCGCQ01580899)
 - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793081 port of SCGCQ01761224)
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01798297 port of SCGCQ01745770)
 - Use scheduler call for heavy operations Part 2.(SCGCQ01792861 port of SCGCQ01746649)
 - SCGCQ01583133: Inconsistency of login dialog box in Manageserver page and Remote discovery page(SCGCQ01793098 port of SCGCQ01583133)
 - Fixed: LSA allows the user to attempt a 3 drive RAID6 VD creation (via RAID60).(SCGCQ01798511 port of SCGCQ01687523)
 - SCGCQ01631835: WG: error log and Access log consume entire OS file system space (6.3 GB and 2.6 GB respectively)(SCGCQ01798635 port of SCGCQ01631835)
 - LSA: SnapDump Implementation(SCGCQ01788680 port of SCGCQ01786658)
 - Enhance Properties panel of Individual elements.(SCGCQ01792093 port of SCGCQ01613898)
 - Handle Progress events without initiating further api call from Client.(SCGCQ01792974 port of SCGCQ01761196)
 - LSA Client Logging.(SCGCQ01792995 port of SCGCQ01752841)
 - LSA Client: Enhance view server profile(SCGCQ01793196 port of SCGCQ01613529)
 - LSA: SnapDump Implementation.(SCGCQ01793838 port of SCGCQ01786658)
 - (SCGCQ01798366 port of SCGCQ01628367)
 - Implemented: LSA: Disable Cached IO option during VD creation(SCGCQ01798387 port of SCGCQ01697006)
 - LSA Server: Optimize the operation areas of UI to add “on demand” call and increase the performance.(SCGCQ01793279 port of SCGCQ01745789)
 - Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01794950 port of SCGCQ01793057)
 - SCGCQ01595244: WG: issues pertaining to lsa logs file generation in VMware.(SCGCQ01798451 port of SCGCQ01595244)
 - Adding filters to the PD and VD table.(SCGCQ01625154 port of SCGCQ01614984)
  - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01798299 port of SCGCQ01731931)
 - WG: Enclosure position is not shown in Progress bar PD details for any enclosure above position index=1 as well as event logs.(SCGCQ01801670 port of SCGCQ01794642)
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives).(SCGCQ01818637 port of SCGCQ01803743)
  - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01818638 port of SCGCQ01809413)
 - Adding filters to the PD and VD table.(SCGCQ01807941 port of SCGCQ01614984)
 - Implementation of LW Agent Related Back-end changes.(SCGCQ01801403 port of SCGCQ01591705)
 - Add SCSI Unmap property at PD level.(SCGCQ01813071 port of SCGCQ01732785)
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01818554 por of SCGCQ01680714)
 - WG: Duplicate PD entires of replace Drive listed in PD list of controller console page on sorting the PD list more than twice.(SCGCQ01803785 port of SCGCQ01794631)
 - WG: View more properties pane is overlapped by the progress bar if the progress info is in expanded state.(SCGCQ01803986 port of SCGCQ01763142)
- MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813180 port of SCGCQ01813078)
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG.(SCGCQ01818631 port of SCGCQ01803722)
 - Unable to import foreign secured VDs with different security key.(SCGCQ01818678 port of SCGCQ01670139)
 - LSA needs proper message for max config import.(SCGCQ01813926 port of SCGCQ01764977)
 - MR7.6: LSA crashed with a mouse click on VD.( SCGCQ01819577 port of SCGCQ01641760)
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01822126 port of SCGCQ01686080)
 -.(SCGCQ01824435 port of SCGCQ01317424)
 -.( SCGCQ01827729 port of SCGCQ01808698)
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01837518 port of SCGCQ01802344)
 - handling the session management.(SCGCQ01841323 port of SCGCQ01829897)
 - LSA PD slot numbering doesn't not display as ascending order by default(SCGCQ01415337 port of SCGCQ01406115)
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config(SCGCQ01838336 port of SCGCQ01818953)
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config(SCGCQ01838335 port of SCGCQ01817275)
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01837786 port of SCGCQ01745768)
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01838449 port of SCGCQ01818960)
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01839325 port of SCGCQ01737550)
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01845011 port of SCGCQ01841473)
 - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons(SCGCQ01848661 port of SCGCQ01840475)
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01847352 port of SCGCQ01763742)
 - LSA Client: Improving visible / working area on elements tab(SCGCQ01839616 port of SCGCQ01837412)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01879301 port of SCGCQ01874487)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830499 port of SCGCQ01761830)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830498 port of SCGCQ01761830)
 - Drive status not displayed in Other Hardware tab(SCGCQ01855592 port of SCGCQ01849636)
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01874490 port of SCGCQ01866289)
 - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons.(SCGCQ01864285 port of SCGCQ01840475)
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01852072 port of SCGCQ01851906)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS..(SCGCQ01869568 port of SCGCQ01829895)
 - LSA Not allowing to clear/Import foreign configuration..(SCGCQ01860931 port of SCGCQ01849749)
 - LSA Client : 7.8 Coverity defects fix.(SCGCQ01865174 port of SCGCQ01837314)
 - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01855872 port of SCGCQ01827404)
 - LSA is allowing to delete OS VD.(SCGCQ01883000 port of SCGCQ01873420)
 - Implementation of LW Agent Related Back-end changes.(SCGCQ01801314 port of SCGCQ01591705)
 - LSA is allowing to delete OS VD.(SCGCQ01906734 port of SCGCQ01873420)
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01905909 port of SCGCQ01886563)
 - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.( SCGCQ01906795 port of SCGCQ01893511)
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01893311 port of SCGCQ01761269)
 -LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01890993 port of SCGCQ01829669)
 -.(SCGCQ01914269 port of SCGCQ01906844)
 - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.(SCGCQ01914265 port of SCGCQ01893511)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921950 port of SCGCQ01856350)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab.(SCGCQ01962269 port of SCGCQ01898255)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368)
 - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01962278 port of SCGCQ01952143)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD.(SCGCQ01972651 port of SCGCQ01966687)
 - SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA) Uninstall Error: "Option “-x” is deprecated" w/ Linux RHEL 7.6.(SCGCQ02002118 port of SCGCQ01993697)
 - (CSETActivity) - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state.(SCGCQ02032206 port of SCGCQ02021372)
 -.(SCGCQ02034407 port of SCGCQ02030621)
 - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress.(SCGCQ02044809 port of SCGCQ01973705)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171)
 - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929)
 - Memory Leak issues LSA Build (7.009.007.00)(SCGCQ02042291 port of SCGCQ02006229)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781)
 - Issues wrt the linux installer script(SCGCQ02044832 port of SCGCQ01879303)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ02001873 port of SCGCQ01856350)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300)
 -(SCGCQ02043859 port of SCGCQ01927978)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895)
 - SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611)
 - LSA Client : Trigger and Download Snap Dump from application(SCGCQ02032043 port of SCGCQ01917087)
 - WG: No Action Successful notification shown on Drive erase(single Drive), Application Version shown as undefined for VMware(SCGCQ02032617 port of SCGCQ01941129)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL) when Drive security is enabled.(SCGCQ02042097 port of SCGCQ01993099)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02053863 port of SCGCQ02035322)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02070858 port of SCGCQ02070840)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322)
 - Fixed: Calculation to get possible range for RLM(SCGCQ02093538 port of SCGCQ02070841)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515)
 - Fixed: Calculation to get possible range for RLM(SCGCQ02093240 port of SCGCQ02070841)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537)
 
EnhancementRequest:
 -Update candidate drive list for VD creation when UNMAP/FDE etc Exist.(SCGCQ01879211)
 -Aero None-Mode implementation.(SCGCQ01871350)
 -Add CTRL_SB_SOFT_SECURE_MODE event to indicate soft secure mode.(SCGCQ01965721)
 -LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog.(SCGCQ02044922)
 -LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048)
 -LSA Standalone - enhanced authentication/authorization (Windows).(SCGCQ01984624)
 - Increase in MR_PD_INFO.name length to 32 characters.(SCGCQ02079068)
 -Better error message for certain unmap operations.(SCGCQ02111563)
 - MR Windows IOCTL Error codes to Application added to MR API.(SCGCQ02103183)
 - API change to support NVMe Passthrough over OOB.(SCGCQ02035295)
 - API change to support new DCMD for consolidated device list.(SCGCQ02037158)
 - Customer needs to generate and extract the On-demand based debug data both for MR and iMR..(SCGCQ02000566)
 - Modification in MR_SNAPDUMP_TRIGGER_TYPE enum value.(SCGCQ02030653)
 - Reword event log messages as it creates unnecessary panic..(SCGCQ02013675)
 - Add New Generic OOB API To Read ROC Temp, Drive Temp, Drive Type, Drive Protocol and status through OOB BMC.(SCGCQ01940661)
 - Add a bit for atomic descriptor capable.(SCGCQ01965047)
 - Additional details about spare.(SCGCQ02033538)
 - API changes for Lane Margining.(SCGCQ01921241)
 - Introduced new controller bit.(SCGCQ01985474)
 - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change.(SCGCQ02103973)
 - Driver parameter bit for support of tool box cmd.(SCGCQ02002119)
 - API change to support new DCMD for consolidated device list.(SCGCQ02016723)
 - .(SCGCQ01740789)

004.189.000.000 - Moderate Impact
---------------

-(SCGCQ01351380) 
 - WG: Physical Drives tab should be aligned in center for Advanced Configuration.(SCGCQ01440777) 
 - Fixed: settings in configuration service API is inconsistent with other applciations(SCGCQ01518134) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01534444) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01539326) 
 - LSA Client 7.6: SPAN drives order is not maintained(SCGCQ01539355) 
 - Client: LSA should handle the not empty check for enclousre field for the physicalDevices response(SCGCQ01555968) 
 - IT-FURY-PH16:LSA-4.126.0.0-Fully Populated Enclosure S/N is "NA" and shown correctly after few drive removals.(SCGCQ01563352) 
 - SCGCQ01565134: IT-Ventura-PH7:LSA-4.126.0.0- FW update fails with error "File size Exceeds 16MB".(SCGCQ01565134) 
 - WG : Server detail is getting populated twice when user is using local IP (127.0.0.1(SCGCQ01565327) 
 - WG: During VD Creation on Simple Configuration, Clicking more than Once on the Finish Button is giving a Wrong Message.(SCGCQ01569262) 
 - WG: Copyright info is shown as 2017 instead of 2018(SCGCQ01571088) 
 - WG:Pop Up scroll missing in case there are more number of VDs to add while setting patrol read properties & Schedule CC(SCGCQ01571089) 
 - WG: User is notified to that multiselect PD/VD displays the properties but it is not supported(SCGCQ01571095) 
 - IT-FURY-PH16:LSA-SATA NCQ bit is always shown as disabled(SCGCQ01571261) 
 - LSA is not responding if online state is changed to offline(SCGCQ01571453) 
 - SCGCQ01571863: WG: LSA installation/uninstallation on linux does not notify the user on success or failure(SCGCQ01571863) 
 - Fixed: Windows OS details were reported as VMware details in Manual Search(SCGCQ01571874) 
 - WG: LSA wrapper indicates the progress of operations appears to be clickable while there is nothing user can select from list(SCGCQ01573087) 
 - SCGCQ01575706: WG:LSA installation exits on invalid option for selecting range of LSA events, it asks for retry with options listed again(SCGCQ01575706) 
 - SCGCQ01575999: FURY-PH16:LSA-Model Number is getting truncated for ST3000DM001,Hitachi HDS723020BLA642 models.(SCGCQ01575999) 
 - WG: the string 'status' is displayed multiple times after searching the server for manual addition(SCGCQ01577707) 
 - WG: LSA allows to replace HDD missing drive with SSD UG drive, fails with Partial Success.0 Successful;1 Failed notification(SCGCQ01577769) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01578248) 
 - LSA Server: Removal of Additional Carriage Returns and Line feeds in tty log file(SCGCQ01579290) 
 - WG: Error message on a failed VD creation is displayed outside the allocated space(SCGCQ01586721) 
 - SCGCQ01588880:(SCGCQ01588880) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01590450) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01595641) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01601386) 
 -(SCGCQ01628332) 
 - fixed: Advanced Configuration is grayed out when there are 2 jbods available in the system.(SCGCQ01631267) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01669558) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01675460) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01681070) 
 - WG: LSA 7.7 PA2 Not able to create RAID 00 VDs on iMR Ventura controller(SCGCQ01683638) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01683938) 
 - During migration from r0(opal drives and non-secured) to r1, Add Pd list does not list the available drives (Greater/same si(SCGCQ01687072) 
 - WG: Issues pertaining to searching of the server : manual discovery in list view & GUI issues in the manual discovery panel(SCGCQ01687117) 
 - MR7.7_LSA: Unable to convert JBOD to UG when filesystem is present(SCGCQ01697980) 
 - LSA Linux doesn't have latest storelib(SCGCQ01713580) 
 - WG MR 7.7 PA2: LSA allows to add FDE and OPAL drives to create Encrypted volume(SCGCQ01721222) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01761801) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01761830) 
 - Fixed: nvme is allowed to mix with sas /sata(SCGCQ01762948) 
 - SCGCQ01763132: LSA: Alert Configuration response contains unsupported character(SCGCQ01763132) 
 - Foreign Config preview should show the VD details also(SCGCQ01788639) 
 - LSA Opal: RLM mixing for Opal SSC and Enterprise shouldn't be allowed when enableFDETypeMix=0(SCGCQ01790063) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) 
 - compilation error in server(SCGCQ01817434) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01841473) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856350) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - WG: LSA shows incorrect popups while making the drive from offline to online & vice versa(SCGCQ01922610) 
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01937406) 
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971368) 
 -(SCGCQ01542415) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01552654) 
 - Correcting the library version display, ini file contents and also the readme files contents.(SCGCQ01561849) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01564526) 
 - SWR: Device ID is not displayed in LSA.(SCGCQ01564621) 
 - MR/IR: Controller Device ID value mismatch in LSA(SCGCQ01564622) 
 - WG:LSA and web server port have references of SLIM and nignx in notification if invalid ports are given during LSA installatn(SCGCQ01571099) 
 - WG: Issues pertaining to replace drive confirmation popup(SCGCQ01573101) 
 - Security related information should not be displayed in IR/IT for LSA(SCGCQ01577891) 
 - LSA allows user to assgin a 512 B drive as replacement to 4k missing drive in a DG(SCGCQ01591175) 
 - SCGCQ01593058: Add non printable character support for sata pd product id display(SCGCQ01593058) 
 - Add a provision to indicate VMware/NonVmware server in Manual Discovery Panel(SCGCQ01600706) 
 - LSA WG FURY IT: UEFI image download is failing in LSA(SCGCQ01616545) 
 - LSA 7.6 Server: LSA is showing the option for PD:"Undo Prepare For Removal", when the DG is in TR state(SCGCQ01618243) 
 - Not able to create secure VD with latest MR 7.7 LSA 177.000.000-SCGCQ01664972 but OK with previous version(SCGCQ01665121) 
 - Error observed while adding Windows gateway server in through manual discovery(SCGCQ01675601) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01677101) 
 - LSA MR7.7 PA2: Previously cleared configuration is seen in presence of OPAL foreign drive in Jbod Mode.(SCGCQ01685488) 
 - WG MR7.7 PA2:Once the 69639 error code is seen in LSA, performing every valid operation fails until manual refresh is perfo(SCGCQ01686013) 
 - WG MR 7.7:There is no import option for GHS Foreign device in LSA(SCGCQ01698105) 
 - Fixed: LSA handle count increase was observed(SCGCQ01713154) 
 - Add physical Drives page is not consistent across (Advanced Configuration and Modify drive Group(SCGCQ01716606) 
 - LSA: Handle Opal drive scenario for Hotspare and replace drive(SCGCQ01719043) 
 - LSA client: Add support to show incompatible profiles details(SCGCQ01727270) 
 - Add SCSI Unmap property at PD level(SCGCQ01732785) 
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01745770) 
 - WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile(SCGCQ01747490) 
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline.(SCGCQ01752969) 
 - [CISCO][TR]"Clear Transport Ready" option on rebuild LD should be removed or greyed out in LSA(SCGCQ01753229) 
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01761269) 
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01763742) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813078) 
 - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01833469) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01838943) 
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01886563) 
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01918692) 
 -(SCGCQ01534450) 
 - LSA needs to change "Error code" : 86017, Description:Operation failed because of a resource reservation error" to proper mes(SCGCQ01556013) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01581943) 
 - SCGCQ01582139: MR7.6_LSA: Enclosure ID and Device ID is shown blank in LSA event logs(SCGCQ01582139) 
 - WG: LSA Page auto scrolls down with scheduler wrapper going out of focus. LSA page would now be only half transparent(SCGCQ01586697) 
 - PH7 LSA WG Ventura: Sorting the drives on the basis of Device ID is not working fine(SCGCQ01587630) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01593855) 
 - WG: Instance validation failed for controller GET(SCGCQ01601458) 
 - WG: Minor text changes to be made in user information when no rows are selected in PD tab / DG tab / other hardware tab(SCGCQ01601656) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01615856) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01638193) 
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress(SCGCQ01680714) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01685449) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01686024) 
 - Instant Secure Erase does not work in VMware when schedule is enabled(SCGCQ01686028) 
 - MR7.7_LSA: Error code:0 is observed when driver security is changed in LSA(SCGCQ01686050) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716622) 
 - fixed: max pd is a bigger number than the actual allowed max pd per raid level(SCGCQ01746200) 
 - WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection(SCGCQ01764794) 
 - WG: gateway system is not discovering systems with different web port number in remote discovery page.(SCGCQ01788630) 
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives)(SCGCQ01803743) 
 - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01809413) 
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) 
 - fixed: Info "1920 more drives can be added" need to change in LSA(SCGCQ01827401) 
 - The display wrong location in page(SCGCQ01836732) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01355833) 
 - WG: Changing the drive security key with invalid authentication key results in notification that is not in format(SCGCQ01573090) 
 - WG: Raid 00 DG having missing drives Span list dissapears when user tries to sort the drives based on capacity(SCGCQ01577833) 
 - MR 7.7: LSA did not allow to pick all SED/FDE but OK to pick one by one when create secure VD(SCGCQ01629062) 
 - SCGCQ01718994: LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01718994) 
 - When there is pending personality, do not allow behavior Mode change, GUI refresh issue(SCGCQ01731312) 
 - Assign DHS is not showing any message in failure case(SCGCQ01732485) 
 - To enable the Alarm user has to click on the bottom of checkbox(SCGCQ01740783) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01818960) 
 - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives(SCGCQ01850008) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) 
 - LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01533554) 
 - WG: change Behavior Mode From JBOD to None is Not Working until closing the window(SCGCQ01635541) 
 - WG MR7.7PA2:In Jbod mode after first reboot and after converting Jbod to UG, advance configuraton leads to Jbod table.(SCGCQ01683001) 
 - MR 7.7 PA2: LSA does not refresh DG icon when PDs are made offline to online and visa versa.(SCGCQ01686029) 
 - WG MR 7.7 PA2:Encrypted Opal drive VD supports the Opal drive replacement with FDE drive(SCGCQ01697265) 
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button(SCGCQ01737550) 
 - MR 7.7 alpha: LSA displays raid 1 as raid 1E when created using 4 drives.(SCGCQ01764771) 
 - SCGCQ01564386: IT-FURY-PH16:Drives are not listed under Enclosures ( "0" drives) under other Hardware if connected in Multipath.(SCGCQ01564386) 
 - Coverity Defect fix in 7.7 Stream(SCGCQ01682365) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01714415) 
 - Client changes for defect SCGCQ01629703(SCGCQ01714659) 
 - MR7.7_LSA: After disabling PR, PR properties shows next scheduled time(SCGCQ01718119) 
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG(SCGCQ01803722) 
 - LSA is not locating all drives correctly(SCGCQ01924674) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01515496) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01563343) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01629574) 
 - Fixed: Show Advanced Config menu only if Unconfigured UG is present(SCGCQ01629703) 
 - WG: Readme shows wrong Version of LSA in html\files\LSA_ReadMe\LSA_Readme(SCGCQ01822525) 
 - SCGCQ01822561: WG: Changed LSA port is not listed after Direct agent installation on Rhel(SCGCQ01822561) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01866289) 
 - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01564627 port of SCGCQ01542412) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01564633 port of SCGCQ01562368) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01564739 port of SCGCQ01545262) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01564943 port of SCGCQ01534444) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565025 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01565116 port of SCGCQ01555955) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01566088 port of SCGCQ01562368) 
 - WG: No success or failure notification is shown on enabling the JBOD drive security(SCGCQ01566435 port of SCGCQ01511274) 
 - SCGCQ01545384: Installation of LSA with LWM option is showing installation_type = 0, in the LSA.conf file(SCGCQ01567110 port of SCGCQ01545384) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569267 port of SCGCQ01504080) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01569465 port of SCGCQ01542412) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01569474 port of SCGCQ01539349) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01569949 port of SCGCQ01563340) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01570203 port of SCGCQ01550970) 
 - Enclosure's physicaldevices URI getting failed with 405 error(SCGCQ01589492 port of SCGCQ01523122) 
 - Label of the user menu drop down should change reinforcing that selection worked.(SCGCQ01597876 port of SCGCQ01493942) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01599402 port of SCGCQ01563340) 
 - Version changes for LSA 4.129 common project(SCGCQ01601148 port of SCGCQ01601146) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601603 port of SCGCQ01598515) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01604992 port of SCGCQ01564526) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01605344 port of SCGCQ01581943) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01609343 port of SCGCQ01578248) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01614982 port of SCGCQ01355833) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01616555 port of SCGCQ01595641) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01617930 port of SCGCQ01401460) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01628354 port of SCGCQ01504080) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01634072 port of SCGCQ01473733) 
 - WG: few of the alert params have the missing controller ID tag for the events(SCGCQ01635756 port of SCGCQ01625923) 
 - LSAServer: Use scheduler call for heavy operations for performance improvement - PD Operations(SCGCQ01635765 port of SCGCQ01514283) 
 - WG: though the hotspare button will be disabled after adding VD for a Raid 1 DG, the hand cursor button appears(SCGCQ01635778 port of SCGCQ01626738) 
 -(SCGCQ01639457 port of SCGCQ01599526) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01685343 port of SCGCQ01641760) 
 - Raid 1 Volume creation using 4 drives is displayed as Raid 1E(SCGCQ01686231 port of SCGCQ01686106) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687172 port of SCGCQ01686080) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01697468 port of SCGCQ01683941) 
 - LSA fails to flash GPMR2 package 50.1.0-1048 on top of MR 7.6 package 50.6.0-1255 on first try-it is successful on 2nd try(SCGCQ01697485 port of SCGCQ01680521) 
 - LSA not showing the proper time stamp in the schedule PR page(SCGCQ01698028 port of SCGCQ01677008) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01719179 port of SCGCQ01515496) 
 -(SCGCQ01733306 port of SCGCQ01721811) 
 - Fixed: LSA handle count increase was observed(SCGCQ01742153 port of SCGCQ01713154) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01747012 port of SCGCQ01745768) 
 - Server schema validation is failing(SCGCQ01764913 port of SCGCQ01619401) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01764928 port of SCGCQ01638193) 
 - LSA installation failed on SLES15(SCGCQ01784699 port of SCGCQ01760620) 
 - LSA needs proper message for max config import(SCGCQ01789100 port of SCGCQ01763411) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) 
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup(SCGCQ01810649 port of SCGCQ01803341) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813086 port of SCGCQ01813078) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01816649 port of SCGCQ01686080) 
 - C480-M5: LSA downloaded event log needs better decoding(SCGCQ01828830 port of SCGCQ01321211) 
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) 
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab(SCGCQ01851980 port of SCGCQ01851906) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01897266 port of SCGCQ01818960) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01901774 port of SCGCQ01866289) 
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915861 port of SCGCQ01905192) 
 - [CISCO]LSA shows previously set security key (M3g@raid(SCGCQ01921581 port of SCGCQ01878346) 
 - LSA fails to start initialization on EPD if it has DDF(SCGCQ01921583 port of SCGCQ01849522) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) 
 -(SCGCQ01921684 port of SCGCQ01841361) 
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event(SCGCQ01921836 port of SCGCQ01876230) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01538488 port of SCGCQ01473733) 
 -(SCGCQ01564591 port of SCGCQ01515389) 
 - WG: System display uniformity is not there in GUI (Remote server discovery(SCGCQ01567177 port of SCGCQ01553588) 
 - Client: Handle Enable/Disable style for search Button(SCGCQ01567216 port of SCGCQ01539573) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01567307 port of SCGCQ01545262) 
 - Manual discovery of servers(SCGCQ01569264 port of SCGCQ01539471) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569569 port of SCGCQ01504080) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01570076 port of SCGCQ01563340) 
 - Converting the JBOD Pds to Unconfigured good PD during VD creation VD creation(SCGCQ01597581 port of SCGCQ01518204) 
 - Manual discovery of servers(SCGCQ01600837 port of SCGCQ01539471) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01615020 port of SCGCQ01552654) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01615042 port of SCGCQ01601386) 
 -(SCGCQ01633836 port of SCGCQ01599526) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01635183 port of SCGCQ01593855) 
 - Use schedular call for heavy operations for performance imporvement(SCGCQ01635665 port of SCGCQ01506032) 
 - Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01635761 port of SCGCQ01518113) 
 - JBOD Mode : WG: Even after clicking Convert JBOD the JBOD conversion page does not refresh with updated list(SCGCQ01635784 port of SCGCQ01617721) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676612 port of SCGCQ01670094) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676732 port of SCGCQ01670094) 
 -(SCGCQ01685548 port of SCGCQ01685009) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01686054 port of SCGCQ01685449) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687173 port of SCGCQ01686105) 
 - fixed: WG: managing the manually added server fails : windows(gateway(SCGCQ01697195 port of SCGCQ01682360) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716641 port of SCGCQ01716622) 
 -(SCGCQ01718985 port of SCGCQ01698211) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01788477 port of SCGCQ01629574) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880123 port of SCGCQ01876091) 
 - handling the session management(SCGCQ01892868 port of SCGCQ01829897) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01898263 port of SCGCQ01802344) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01901754 port of SCGCQ01827404) 
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives.(SCGCQ01904075 port of SCGCQ01893304) 
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904345 port of SCGCQ01901758) 
 -(SCGCQ01920699 port of SCGCQ01808698) 
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01921839 port of SCGCQ01829669) 
 - SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS(SCGCQ01921842 port of SCGCQ01803373) 
 - WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674) 
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command(SCGCQ01930623 port of SCGCQ01926876) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01557738 port of SCGCQ01539349) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01564629 port of SCGCQ01550970) 
 - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message(SCGCQ01564682 port of SCGCQ01547992) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01569579 port of SCGCQ01514206) 
 - Support from LSA back-end to allow JBODs to be converted to UG for advance VD creation(SCGCQ01597602 port of SCGCQ01519271) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01670841 port of SCGCQ01629821) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01676281 port of SCGCQ01615856) 
 - Server schema validation is failing(SCGCQ01676389 port of SCGCQ01619401) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01679003 port of SCGCQ01563343) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01680728 port of SCGCQ01677101) 
 - LSA taking more time to discover VMWare servers(SCGCQ01681092 port of SCGCQ01681069) 
 -(SCGCQ01697478 port of SCGCQ01685009) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716625 port of SCGCQ01716622) 
 -(SCGCQ01718980 port of SCGCQ01698211) 
 -(SCGCQ01749087 port of SCGCQ01698211) 
 - Modify Properties option is enabled for VDs which are part of Transport Ready Drive Group(SCGCQ01764894 port of SCGCQ01763056) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01826237 port of SCGCQ01761830) 
 - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation(SCGCQ01837378 port of SCGCQ01833791) 
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA(SCGCQ01851919 port of SCGCQ01841280) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856730 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01891168 port of SCGCQ01889547) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD(SCGCQ01897144 port of SCGCQ01817275) 
 - Update the Windows Server 2019 OS name in LSA(SCGCQ01897178 port of SCGCQ01866322) 
 -(SCGCQ01920924 port of SCGCQ01818618) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921819 port of SCGCQ01856350) 
 - LSA 7.6 Client: Cosmetic replace drive selection issue(SCGCQ01566455 port of SCGCQ01539347) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01567176 port of SCGCQ01539326) 
 - WG: Alignment in Remote Server Discovery page changes when it is in List view and filtered with any one of the OS type.(SCGCQ01567193 port of SCGCQ01471834) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569137 port of SCGCQ01538253) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569138 port of SCGCQ01538253) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01569488 port of SCGCQ01540821) 
 - Client:Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01597592 port of SCGCQ01518206) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601608 port of SCGCQ01598515) 
 - WG: empty details for policy change displayed in events "Previous = Current Write Policy: Now = Current Write Policy:"(SCGCQ01635759 port of SCGCQ01625912) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01635779 port of SCGCQ01629821) 
 - TR VD should be excluded from the PR VD list(SCGCQ01677110 port of SCGCQ01677062) 
 - Implemented: Allow mixing of nvme drives to be mixed with SATA/SAS drives(SCGCQ01697042 port of SCGCQ01697026) 
 - Hercules : Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails(SCGCQ01789156 port of SCGCQ01731931) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01816428 port of SCGCQ01641760) 
 - Handling the set text mechanism in client(SCGCQ01886532 port of SCGCQ01850387) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01897181 port of SCGCQ01841473) 
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,(SCGCQ01915812 port of SCGCQ01906914) 
 - LSA 7.8:Import option is given for the Incomplete foreign VD(SCGCQ01921678 port of SCGCQ01865420) 
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01961510 port of SCGCQ01889547) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01697480 port of SCGCQ01681070) 
 - Add Virtual Drive option is available for DGs with Transport Ready feature set(SCGCQ01764885 port of SCGCQ01763052) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01828400 port of SCGCQ01538253) 
 - Fixed: Crash when pressing back button after logout(SCGCQ01892905 port of SCGCQ01865309) 
 - Remove un printable characters from LSA log(SCGCQ01901769 port of SCGCQ01901760) 
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) 
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives(SCGCQ01921580 port of SCGCQ01823858) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565119 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01569761 port of SCGCQ01555955) 
 - Unable to import foreign secured VDs with different security key(SCGCQ01731357 port of SCGCQ01670139) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01794950 port of SCGCQ01793057) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01817915 port of SCGCQ01793057) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01897099 port of SCGCQ01761801) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01564631 port of SCGCQ01540821) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01679329 port of SCGCQ01675460) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01698150 port of SCGCQ01590450) 
 - LSA needs proper message for max config import(SCGCQ01813925 port of SCGCQ01764977) 
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) 
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01564737 port of SCGCQ01514206) 
	
EnhancementRequests:
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399204) 
 - Part 2 of 2: Support TCG Opal 2.0 via SafeStore for VDs and SystemPD (Legacy JBOD) in RAID Mode and JBOD/SDS Modes(SCGCQ01599762) 
 -(SCGCQ01740789) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399205) 
 - Manually add server details to the list of servers(SCGCQ01539514) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01740787) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01401460) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746609) 
 - Manual discovery of servers(SCGCQ01539471) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01802344) 
 -(SCGCQ01599763) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746608) 

004.069.000.000  - Moderate Impact
--------------- 
Defects (20)
-.(SCGCQ01753405)
- Server: LSA GUI Not Updating Security Key Info.(SCGCQ01761801)
- CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275)
- Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404)
- Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01841473)
- LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856350)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209)
- fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01833469)
- LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ01838943)
- LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953)
- fixed: Info "1920 more drives can be added" need to change in LSA.(SCGCQ01827401)
- The display wrong location in page(SCGCQ01836732)
- LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01818960)
- LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives.(SCGCQ01850008)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091)
- Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01866289)
- Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305)
- Security Key Confirm Text box should not accept the copy of anything.(SCGCQ01788477 port of SCGCQ01629574)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856730 port of SCGCQ01856350)
- The LSA is failing to take into account current USED PDs from another configured VD during next VD creation.(SCGCQ01837378 port of SCGCQ01833791)
- SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in.(SCGCQ01828400 port of SCGCQ01538253)
- Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01817915 port of SCGCQ01793057)
- SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895)

EnhancementRequests (20)
- RTTrace API Changes.(SCGCQ01745568)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01802344)


004.062.000.000  - Moderate Impact
--------------
fixed:
Nginx versions since 0.5.6 up to and including 1.13.2 are vulnerable to integer overflow vulnerability in nginx range filter module resulting into leak of potentially sensitive information triggered by specially crafted request.https://nvd.nist.gov/nvd.cfm?cvename=CVE-2017-7529.

Defects (109)
- LSA server report for iMR Inv controller displays dedicatedHotSparePerDriveGroup is 0 under "maxLimit".(SCGCQ01375788)
- SCGCQ01393056: Enclosure ID is coming up as null in LSA.(SCGCQ01393056)
- WG: Error message not fitting inside the message box in "Enable Drive Security" page..(SCGCQ01442477)
- WG: Issues pertaining to 'Make JBOD Secure' Pop up.(SCGCQ01446801)
- PerfImp: Don't handle SLIM_EVT_EXCEEDS_MAX if there is no event requires complete refresh.(SCGCQ01447165)
- WG: UI Pattern in "Virtual Drive Settings" is not uniform while creating and modifying VD properties..(SCGCQ01447697)
- WG: "Change" button shown as disabled when user tries to change Behavior mode..(SCGCQ01450713)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG: success message box for "change personality" does not have proper border.(SCGCQ01453980)
- WG: Event Log table headers needs space - Cosmetic.(SCGCQ01460053)
- WG: Notification after saving the changes in "Manage Power Save Settings" needs cosmetic change..(SCGCQ01460078)
- Requested personality field is not updated for Ventura.(SCGCQ01465642)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)
- WG: Tooltip for help link in "Remote Server Discovery" page is not displayed..(SCGCQ01471842)
- WG: "Available UG drives" form is shown blank when "Type" is selected from ALL to any other drives..(SCGCQ01472186)
- WG: LSA showing inappropriate message after securing a DG using FDE security..(SCGCQ01472201)
- Buttons are inconsistent in Email Settings page of LSA.(SCGCQ01472752)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.().(SCGCQ01474461)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01482320)
- During Advanced Vd Creation PD selection order is not maintained by the client.(SCGCQ01498969)
- Display the ROC temperature in Fahrenheit as well along with Celsius.(SCGCQ01504619)
- WG: Hand mouse pointer is used in " Background Process progress " window , where it shows the name of background operations..(SCGCQ01505999)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Caps letter is expected in Settings for Alert settings successful and restore default value successful message..(SCGCQ01509253)
- WG: Sorting of drives by model number does not work for JBOD drives.(SCGCQ01511247)
- Do not allow the user to manage Personality Panel if set personalty is not supported.(SCGCQ01514527)
- SCGCQ01515443: WG: Typo in Event ID: 114 of PD state Change event related to sheild state.(SCGCQ01515443)
- 502 bad gate way observed on enclosure cable push/pull.(SCGCQ01524150)
- WG : LSA allows to add VD on offline DriveGroup and operation fails anyways.(SCGCQ01526342)
- MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01532725)
- LSA shows wrong diskgroup info when you have foreign PD.(SCGCQ01590450)
- Lenovo_18B: Not able to set max no of PD using set patrol read properties in LSA/Storcli.(SCGCQ01681070)
- Fixed: LSA handle count increase was observed.(SCGCQ01713154)
- Lenovo CIT 18B: LSA Linux doesn't have latest storelib.(SCGCQ01713580)
- SCGCQ01385340: Health is not coming proper after foreign config import..(SCGCQ01385340)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389892)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01419325)
- WG: Not all space in "Foreign Configuration" tab is clickable..(SCGCQ01467702)
- WG: Font style across the "Advanced Configuration" form should be made same..(SCGCQ01472063)
- Removing dead code from LSA7.5 stream..(SCGCQ01472185)
- WG: "Ok" button needs to be in caps in "Mixed listed drives" confirmation page and one more cosmetic change..(SCGCQ01472190)
- WG: There is no alignment for the error message while user changes the personality mode when PR is in progress..(SCGCQ01474932)
- WG: LSA is not allowing User to change No of PD's allowed for Patrol Read in Set PR properties through KeyBoard..(SCGCQ01479402)
- WG: Trying to clear configuration does not show any warning in server summary page regarding cached data, in CC page it shows.(SCGCQ01486698)
- WG: Select all check box is still selected even if one of the drive group is unselected while assigning HSP to existing DG.(SCGCQ01488141)
- WG: while creating FDE VD, type by default is selected as "All" in PD selection pane, unable to select all FDE drives.(SCGCQ01488169)
- Requested personality field is not updated for Ventura.(SCGCQ01494598)
- temperature change in controller is not refeclected in LSA..(SCGCQ01500344)
- Set patrol read window shows a time in past..(SCGCQ01503810)
-.(SCGCQ01508528)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01509259)
- WG: LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01509708)
- LSA Server: Set Patrol read is not shown when the volume is created with SSD.(SCGCQ01511260)
- SCGCQ01513209: WG: Simple configuration tab show invalid options before the raid level drop down list the supported raid levels.(SCGCQ01513209)
- WG : Advanced configuration tab gets disabled after secure erasing the FDE foreign drives.(SCGCQ01514728)
- SCGCQ01521013: MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01521013)
- MR 7.5_LSA: LSA keeps on refreshing during the background operations- Full init, RLM, CC etc.(SCGCQ01522807)
- WG: Behavior mode is missing in "personality management" window..(SCGCQ01523045)
- SCGCQ01525738: MR 7.5_LSA: Wrong nginx version is reported in linux ( SLES and RHEL ) Operating Systems..(SCGCQ01525738)
- Instance validation issues with LSA build 4.55 with IR3 controller.(SCGCQ01528425)
-.(SCGCQ01628332)
- WG: Current Profile is not selected by default in the table that lists the available profiles for the controller..(SCGCQ01442481)
- WG: "%" is accepted along with the input for Expand VD value - But not accepted for all..(SCGCQ01445384)
- WG: Partition line is required in Controller Properties Page..(SCGCQ01445396)
- WG: Status icon of physical drive is not changed after changing the state of the PD from rebuild to offline..(SCGCQ01461144)
- WG:LSA doesn't allow to secure more than one DG using FDE..(SCGCQ01472853)
- SCGCQ01474327: Handle dynamic length serial number as part of serial number VPD page 0x80.(SCGCQ01474327)
- WG: GUI : Cosmetic issues in clear configuration notificationp.(SCGCQ01486692)
- WG: LSA does not notify the user with notification on starting the VD initialization.(SCGCQ01487270)
- WG: able to add VD for scheduling consistency check even after all the VD's have been deselected.(SCGCQ01489509)
- WG:Add physical Drive button is clickable before VD list is loaded while scheduling CC or PR, no notification to user to wait.(SCGCQ01489885)
- LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01489942)
- LSA: Virtual drive, spare and drivegroup is not supported for IT but seen in URI response for Physical drives..(SCGCQ01500099)
- WG: Selection of different drive type is activated after few clicks.(SCGCQ01503786)
- RWC3 launch tab is showing the LSI Storage Authority.(SCGCQ01503896)
- WG : Pop up for securing FDE drive has inconsistency in text.(SCGCQ01507972)
- In settings window "Restore Default Alert settings" button is not saving the default values.(SCGCQ01508002)
- WG: Confirm Check box is not aligned with the "Enable Security" button.(SCGCQ01511250)
- LSA WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01511390)
- WG:Server Logs does not contain status of energy pack it mentions "Requested element not found in the stack.":error "69634".(SCGCQ01512318)
- WG: Spell Check issues with "message_en.js" used for displaying the GUI notification.(SCGCQ01512377)
- Sorting of Event logs wrt View Events and Download Logs.(SCGCQ01512750)
- WG: LSA add physical Disks pane shows empty drive list even if there are 182 drives for adding for RLM operation.(SCGCQ01513656)
- Controller operations schema instant validation is failed.(SCGCQ01514528)
- WG: LSA shows the message "The virtual disk has not been initialized" even when 32 VD's have been selecte.(SCGCQ01521694)
- Lenovo-18B: IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3.(SCGCQ01595641)
- WG: "Virtual Drive expanded successfully" message is still shown even after the page refresh post VD expansion..(SCGCQ01445693)
- WG: Cosmetic changes required in tooltip messages of Configure options in Controller Actions..(SCGCQ01447797)
- WG: Space is required between RAID and it's type in Available UG drives form and one more cosmetic change..(SCGCQ01472194)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- LSA: partial VD hide operation is failing..(SCGCQ01484118)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01506090)
- WG:Launching LSA using ip:2463 in browser, User can see the HOME page flash before redirecting to Remote discovery.(SCGCQ01439795)
- WG: LSA displays empty box instead of "Action Successful" for "Prepare for removal" and "Undo prepare for removal".(SCGCQ01447823)
- WG: "Adding the virtual drive will add the corresponding virtual drives for PR" is not shown when "select all" box is used..(SCGCQ01461133)
- WG: Size of "Back" & "Save" buttons are not same once the user saves the changes after scheduling CC.(SCGCQ01472749)
- WG: Hand symbol is not seen for close button while Adding drive during reconstruction of a DG.(SCGCQ01473748)
- Disabling the add PD button.(SCGCQ01488036)
- WG: no notification shown on assigning dedicated hotspare to existing DG.(SCGCQ01488155)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01509681)
- WG: Error message on a failed operation of RLM in displayed outside the allocated space.(SCGCQ01515263)
- WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01442471)
- WG: Expand windows is showing the capacity in decimal value with too many integers after decimal point..(SCGCQ01445686)
- Address Code review defects for ER SCGCQ01416373.(SCGCQ01455923)
- WG: Ambiguous "Success" message needs to be changed for disabling drive security.(SCGCQ01461177)
- Cannot import foreign configuration from LSA.(SCGCQ01524354)
- WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space.(SCGCQ01563343)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSABug.(SCGCQ01599526)

EnhancementRequests (20)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
-.(SCGCQ01404233)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461207)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- LSA: Make heavy operation by wrapping scheduler call.(SCGCQ01416373)
 - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443721)
- LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443731)
- Support drive Select ALL functionality in LSA GUI PD Operations and Mixing of drives during vd creation.(SCGCQ01454110)
- SCGCQ01454353: Retrieve and process the ESXi events in a single shot.(SCGCQ01454353)
-.(SCGCQ01454367)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- We will be removing the confirmation popup from all the actions as we got here from multiple forms like this pop up is annoying.(SCGCQ01447015)
- Support drive Select ALL functionality in LSA GUI VD/DG Operations.(SCGCQ01453114)
-.(SCGCQ01472631)

CSETActivities (87)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411631 port of SCGCQ01397546)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01420224 port of SCGCQ01419325)
- LSA service is not working in Linux.(SCGCQ01443712 port of SCGCQ01442733)
- WG: Event Log table headers needs space - Cosmetic..(SCGCQ01464556 port of SCGCQ01460053)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01466763 port of SCGCQ01424621)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Updated PD firmware version is not reflecting even after LSA refresh..(SCGCQ01501204 port of SCGCQ01382013)
- Cisco_Plumus_LR :Proper spacing should be there in between Event and History in view event logs "EventHistory not generated"..(SCGCQ01502201 port of SCGCQ01385344)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure.(SCGCQ01503907 port of SCGCQ01315392)
because of which the issue.(SCGCQ01503926 port of SCGCQ01288032)
- fixed: clear drive should not be candidate drive for create configuration.(SCGCQ01503958 port of SCGCQ01196088)
- Fixed: Span order is in reverse compare to other apps.(SCGCQ01504234 port of SCGCQ01330269)
- LSA shows max pd for Raid 1 without checking support of Raid 1E.(SCGCQ01514472 port of SCGCQ01513338)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531154 port of SCGCQ01521114)
- Making rebuild drive offline lsa gets 404..(SCGCQ01564627 port of SCGCQ01542412)
- LSA Crashes after clicking on foreign configuration.(SCGCQ01564739 port of SCGCQ01545262)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565025 port of SCGCQ01504080)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01565116 port of SCGCQ01555955)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621 )
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01599402 port of SCGCQ01563340)
- MR7.6_LSA: No Foriegn configuration details is shown in LSA.(SCGCQ01605344 port of SCGCQ01581943)
- fixed: logout causing unexpected behavior during end cim connection for vmware systems.(SCGCQ01609343 port of SCGCQ01578248)
- SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page..(SCGCQ01614982 port of SCGCQ01355833)
- LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group..(SCGCQ01617930 port of SCGCQ01401460)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01620406 port of SCGCQ01506090)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01634072 port of SCGCQ01473733)
- Raid 1 Volume creation using 4 drives is displayed as Raid 1E.(SCGCQ01686231 port of SCGCQ01686106)
- Cannot use Special Characters in Domain Name for LSA Login.(SCGCQ01747012 port of SCGCQ01745768)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected..(SCGCQ01448948 port of SCGCQ01442107)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01460039 port of SCGCQ01451571)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts..(SCGCQ01465657 port of SCGCQ00903348)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01466743 port of SCGCQ01451571)
- LSA server giving null for enclosure serial number.(SCGCQ01466744 port of )
- Address Code review defects for ER SCGCQ01416373.( port of SCGCQ01445713)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01484107 port of SCGCQ01482320)
- Added fwflash status as part of controller health status.(SCGCQ01503830 port of SCGCQ01375153)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure because of which the issue.(SCGCQ01503955 port of SCGCQ01288032)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01514258 port of SCGCQ01506045)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01514469 port of SCGCQ01507989)
- Allows raid 1e input even if RAID 1E is not supported by fw.(SCGCQ01514756 port of SCGCQ01513331)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01564633 port of SCGCQ01562368)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- WG: LSA service crashes on trying to login with URI having incorrect mac address of the server.(SCGCQ01615042 port of SCGCQ01601386)
- MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01685343 port of SCGCQ01641760)
-.(SCGCQ01685548 port of SCGCQ01685009)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687173 port of SCGCQ01686105)
- LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716641 port of SCGCQ01716622)
- SDS/HBA progress issues.(SCGCQ01460070 port of SCGCQ01052983)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01460084 port of SCGCQ01435908)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461211 port of SCGCQ01461207)
- C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01501225 port of SCGCQ01321211)
- Cisco - CSCve68492 - Storage Logs display a blank event when a secure PD is unlocked.(SCGCQ01503902 port of SCGCQ01359128)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01514773 port of SCGCQ01509259)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01526363 port of SCGCQ01509681)
- SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message.(SCGCQ01564682 port of SCGCQ01547992)
- LSA: Warning Message needs to be changed when there is Controller firmware update failure.(SCGCQ01604992 port of SCGCQ01564526)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSA.(SCGCQ01633836 port of SCGCQ01599526)
- Secure Jbod unlock is not showing the proper error message in LSA.(SCGCQ01680728 port of SCGCQ01677101)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687172 port of SCGCQ01686080)
- Cisco - CSCvi84075 - LSA, CTRL-R and HII doesn't display the foreign config when MAX VDs are present.(SCGCQ01718980 port of SCGCQ01698211)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460090 port of SCGCQ01460076)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460400 port of SCGCQ01448976)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01481410 port of SCGCQ01474461)
- LSA build script automation for VBAS environment.(SCGCQ01497385 port of SCGCQ01385344)
- Activity to check-in version files in common.(SCGCQ01520315 port of SCGCQ01512599)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- LSA Client 7.6: SPAN drives order is not maintained.(SCGCQ01614833 port of SCGCQ01539355)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline..(SCGCQ01443689 port of SCGCQ01442554)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux..(SCGCQ01480902 port of SCGCQ01479375)
- LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs..(SCGCQ01564943 port of SCGCQ01534444)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565119 port of SCGCQ01504080)
- Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time.(SCGCQ01676612 port of SCGCQ01670094)
- LSA Wont display foreign data when enclosure information in not populated properly.(SCGCQ01686054 port of SCGCQ01685449)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
-.(SCGCQ01564591 port of SCGCQ01515389)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01460393 port of SCGCQ01436886)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive..(SCGCQ01564629 port of SCGCQ01550970)
- LSA WG Fury IT: Controller type is showing as IR for IT card.(SCGCQ01564631 port of SCGCQ01540821)
- I/Os are not recover after drives pull for DHSP to rebuild..(SCGCQ01564737 port of SCGCQ01514206)

4.011.000.000 - Moderate Impact
-------------
Defects (234)
- SDS/HBA progress issues.(SCGCQ01052983)
- Fixed: Added relevant null pointer checks.(SCGCQ01319978)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01321474)
- Start PatrolRead success dialog box needs change in alignment.(SCGCQ01324866)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01325783)
- Link speed is not displaying any details in LSA.(SCGCQ01326129)
- Defect to check in code review defects.(SCGCQ01329391)
- Client js file changes for 7.3.(SCGCQ01331593)
- On Successful Firmware flash client displays improper Icon Message.(SCGCQ01332708)
- Control panel of LSA Help & support link still has reference to LSI. should be changed to broacom.(SCGCQ01337321)
- LSA asks for user permission to navigate away on clicking home button after creating simple configuration.(SCGCQ01338009)
- WG: GUI Issues pertaining to FW flash ER implementation SCGCQ01273627: Request to improve message displayed during FW Update.(SCGCQ01342542)
- IR Card global hot spare assignment is not refreshing the page.(SCGCQ01345357)
- Cisco_HSW_Validation_LSA: LSA accepting decimal values for "Set Adjustable Task Rate" which is saved as round value.(SCGCQ01345553)
- LSA 7.3 Client Coverity fix.(SCGCQ01347309)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01350435)
- WG:descripancies in update firmware page after selecting load bios option.(SCGCQ01350865)
- SCGCQ01350908: WG:Temperature of Unconfigured Drive is displayed as 0C under More properties.(SCGCQ01350908)
- WG:LSA displays Redhat icon in remote discovery page ,though SUSE is installed in system.(SCGCQ01351455)
- LSA taking the max VD size value when the user presses ENTER after specifying the VD size.(SCGCQ01356216)
- SCGCQ01356217: WG: LSA Service crashes on trying the PD details of the simple config created.(SCGCQ01356217)
- LSA_MR_7.3_Alpha: Save option can be grayed out or disabled after user saves the changes for schedule CC.(SCGCQ01357152)
- LSA_MR_7.3_Alpha: LSA doesn't display consistent Foreign Configuration information to the user.(SCGCQ01358048)
- WG: Incorrect notification shown after selecting 32 virtual drives.(SCGCQ01358095)
- SCGCQ01358097: LSA_MR_7.3_Alpha: Space optimization between the size value & size unit is needed in foreign configuration page.(SCGCQ01358097)
- LSA_MR_7.3_Alpha: User cannot select "Advanced Configuration" by clicking on the description below it in Server landing page.(SCGCQ01358122)
- LSA_MR_7.3_Alpha: Space Alignment for better presentation needed in Server Profile Page.(SCGCQ01358148)
- LSA_MR_7.3_Alpha: Percentage value for the Background Operations is not seen if browser is zoomed.(SCGCQ01358261)
- LSA crash when service starts with empty LSA.conf file.(SCGCQ01358264)
- SCGCQ01358892: Buttons "Try Updating Again" is not highlighted when user attempts to flash the firmware after any failure.(SCGCQ01358892)
- SCGCQ01358947: WG: Invalid text Content displayed on selecting multiple Virtual drives/Physical Drives.(SCGCQ01358947)
- WG: "Select Personality" dropdown lists the current personality first by default.(SCGCQ01359030)
- WG: Clickable "hand icon' is not displayed when we move cursor over Bus dev text of controller in Server summary page.(SCGCQ01359034)
- SCGCQ01372670: When User tries to click on Update FW Button, LSA asks for Navigation Confirmation without displaying Update FW page for IT.(SCGCQ01372670)
- "Add CacheCade-SSD VD" tab getting greyed out after deleting created vd,even if physical drive is selected under "Add SSD pd".(SCGCQ01372722)
- WG: VD creation fails when multiple VD's are created with 1MB size.(SCGCQ01373500)
- "Finish" button in Modify drive group work even if its grayed out.(SCGCQ01374945)
- WG: Issues pertaining to Controller Diagnostic logs.(SCGCQ01375839)
- WG: GUI Issues pertaining to Instant secure erase of an FDE Drive.(SCGCQ01375858)
- There is a mismatch about Backplane (Enclosure) "Product ID" and "Enclosure Model" in LSA.(SCGCQ01376005)
- Spare URI does not respond on iMR Invader.(SCGCQ01376605)
- WG: After physically removing the PD from the R10 DG, the DG Span tab does not load.(SCGCQ01376781)
- "Since Log Clear" does not create the last event "Log Clear" in Var/log/messages.(SCGCQ01376849)
- WG: LSA does not list the Drive Group Tab , on creation of 240 VD (15 DG, 16 VD in each of DG) and reinstalling the LSA.(SCGCQ01378585)
- WG: Windows Application Event viewer lists 31 events instead of 30, after installing LSA with the option "Since Last reboot".(SCGCQ01378669)
- WG: LSA does not automatically refresh on hiding an Degraded DG.(SCGCQ01378693)
- Client: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01378778)
- Client: WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01378782)
- WG: unable to start VD initialization on 32 VD's when there are 240 VD created & Foreign configuration present in system.(SCGCQ01378808)
-.(SCGCQ01378812)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01379795)
- WG:In premium features Safe ID & Serial Number needs to be highlited for better understanding.(SCGCQ01379818)
- WG: Close button can be given with a "hand" symbol in Compare and select form like all close button in other form has.(SCGCQ01380587)
- WG: Available Unconfigured drives is not formatted properly for display.(SCGCQ01380591)
- WG: Domain Authentication is shown as Default in "MAnage Server Page".(SCGCQ01380642)
- Size increment button is not working while modifying a VD that is created in MB size.(SCGCQ01380830)
- WG: "Advanced and Simple Configuration" is enabled when UG drives are "prepared for removal" and no other drives are left.(SCGCQ01380977)
- SCGCQ01383828: LSA service crashes while trying to access the IR3 controller.(SCGCQ01383828)
- WG:VD properties were not well partitioned for CacheCade - SSD config , compare to normal VD creation in HDD.(SCGCQ01384561)
- WG: Few enhancements needed in VD Expand form.(SCGCQ01389165)
- SCGCQ01389195: WG: Naming convention for VD can be made consistent for the VD's created through Advanced and Simple configuration.(SCGCQ01389195)
- Enter key is functioning as a backspace in "Set Adjustable Task Rate" - Can be disabled.(SCGCQ01389203)
- LSA mail server settings does not allow to enter name of smtp server.(SCGCQ01389204)
- WG: No. of VD's available to create is not shown properly for spanned vd's when span depth is modified.(SCGCQ01389421)
- Storcli: Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01392000)
- WG: More Actions for drive is not working after staring and stopping Clear operation under Drives tab.(SCGCQ01392056)
- WG: User has to click twice on the table header to change the sorting order for any table in LSA.(SCGCQ01393336)
- Copyright link is taking to top of the page rather taking to Broadcom website.(SCGCQ01393706)
- WG: PD state info is not updated properly in the Drives tab after PD's are converted from online to offline.(SCGCQ01393771)
- WG: "Clear" and "Rescan" buttons could be highlighted for the better look in Foreign Configuration Tab.(SCGCQ01394954)
- "Add Virtual Drives" is grayed out for specific VD sizes after user presses "tab-alt" keys.(SCGCQ01398966)
- WG: Verify and Sign In Buttons are overlapping in list view in Manage Server Page.(SCGCQ01399610)
- LSA is not showing "Activate..." button for Premium Features when it is navigated after "Update Firmware" page.(SCGCQ01399670)
- WG:LSA sending email alert notifications to user which doesn't exist.(SCGCQ01418580)
- Drives under both Physical drives and Span drives tab are allowed to select simultaneously.(SCGCQ01428129)
- Login to VMware is taking at time more than 30 seconds.(SCGCQ01429431)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01435908)
- WG:while editing a created VD, user cannot increase the VD size in MB .Only can decrease the size.(SCGCQ01438268)
- WG:LSA is not sorting properly the drives with different capacity of units i.e TB and GB.(SCGCQ01439751)
- WG: View server profile does not contain info on the Device id, which is sorted according to device id itself.(SCGCQ01440773)
- WG: operation of Combining JBOD drives with & without files system to move to Unconfigurued good is partially successful.(SCGCQ01440778)
- WG: Space required between two strings in the description of "Enable Drive Security".(SCGCQ01442479)
- WG: LSA Displays "Error Code:1:An user is already Logged in with Different Credentials" even user is using same credentials.(SCGCQ01442773)
- WG: LSA is changing to latest login user account though it is already logged with different User Account in different Tab.(SCGCQ01442774)
- WG: No. of UG drives are improperly updated in the Drives header tab when replace operation is triggered on a physical drive.(SCGCQ01444724)
- WG: No. Of Power Supplies info displayed is overlapping on the enclosure details. Need proper display alignment.(SCGCQ01444794)
- LSA showing 'binaryPath:./LSA' during service start in Linux.(SCGCQ01445709)
- LSA server giving null for enclosure serial number.(SCGCQ01445713)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01445719)
- WG: Description for event Code"579" is '0" in LSA event logs.(SCGCQ01446803)
- WG:"Disable Data Protection" is not updating in LSA until user do a manual refresh.(SCGCQ01447843)
- SCGCQ01448707: WG: LSA Event logs has enquiry info for Vendor, model and serial numbers appended with $ symbols.(SCGCQ01448707)
- WG: Inconsistency seen w.r.t making drive online while RLM is in progress.(SCGCQ01449722)
- WG: Event log page is navigating to change personality when the behavior mode is set from other tab of the same browser.(SCGCQ01450719)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG:Controller health status not updated on moving JBOD drive from offline --> online, personality : JBOD.()
- LSA Server: Handling of additional events in Cache module.(SCGCQ01451573)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01464514)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Enclosure ID is shown "Unknown" for NVMe JBOD only in event logs, Profile id=11.(SCGCQ01291162)
- WG: LSA page does not refresh on starting Full initialization on 240 VD.(SCGCQ01292183)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- 7.3 Client : Coverity defects check-in.(SCGCQ01308624)
- SCGCQ01309034: Coverity defect fixes check-in.(SCGCQ01309034)
- Fixed: Code maintainability issue.(SCGCQ01318344)
- coverity defect fies for : Suspicious use of non-short-circuit boolean operaton.(SCGCQ01320079)
- In Simple Config, if user select a VD and select the check box of "Assign HSP", VD size is getting changed to different size.(SCGCQ01321225)
- WG: LSA notifies user that VD will be deleted after VD erase even if the option was not selected.(SCGCQ01325795)
- WG: user notification appearing after user starts/stops the initialization on multiple VD's needs to be updated.(SCGCQ01326134)
- LSA doesn't show FW component name while FW flash operation.(SCGCQ01337028)
- WG: Multiple options of RLM are selected together for radio button used to select one of the 3 RLM operations.(SCGCQ01342615)
- LSA does not display "Link Speed" for phy 8 properly for iMR Ventura.(SCGCQ01355929)
- When the CC is scheduled as "Continuously", it is not reflected in UI after saving the changes.(SCGCQ01357007)
- Warning message has to be corrected in Foreign configuration page and one more hyperlink issue.(SCGCQ01358066)
- LSA is not taking "dot(.)" from num pad , but taking "dot(.)" form keypad while specifying the vd capacity.(SCGCQ01358908)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01364736)
- WG: LSA displays the notification "This operation can be performed only on 32 drives at a time" 32 times.(SCGCQ01373067)
- WG: Global hotspare & Dedicated hotspare are displayed as plural entities for every hotspare listed in physical drive tab.(SCGCQ01375707)
- WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01375778)
- fixed: Min & Max of "PdRaidLevel_1E" under the "pdsForRaidLevels" is populated even though it is not supported in iMR.(SCGCQ01375817)
- WG: Other hardware tab lists wrong count of list of hardware connected when enclosure connected in multipath.(SCGCQ01376109)
- WG: View server profile contents exceed the border limits of the LSA page.(SCGCQ01378556)
- SCGCQ01378774: WG: Information of the virtual drive info and PD's involved in DG vanishes on removing & inserting the PD back from a DG.(SCGCQ01378774)
- WG: Links present in Backplane properties are so light that they look like grayed out. Needs enhancement.(SCGCQ01380680)
- WG: User is allowed to click on "Next" button even if page is not completely updated during the VD creation & RLM operations.(SCGCQ01381734)
- GUI Issues found in Advanced Configuration page.(SCGCQ01381764)
- Firmware flash message should have "new" removed from string.(SCGCQ01382062)
- LSA getting logged in , even if the password is wrong.(SCGCQ01388957)
- "%" is allowed for entering no. of seconds for locating the drives.(SCGCQ01389182)
- WG: Size limit warning is thrown if the user is giving valid size using spinner button while modifying VD.(SCGCQ01389340)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01389483)
- Spinner Button for increase and decrease size is not working when the size is 1.09 TB.(SCGCQ01392053)
- WG: "Username" has to be grayed out when user start typing in the login page of "Manage Server Page".(SCGCQ01393764)
- WG: UG Drives count is not updated properly after modifying a DG.(SCGCQ01393774)
- Phase 5 IT LSA - EFI-BSD version is not displayed fully when Version length is more than 12 characters.(SCGCQ01394914)
- Mismatch in enclosure properties between LSA and storecli utility.(SCGCQ01395021)
- WG: "Managing SAS Storage Link Speed" opens up on clicking help topic of "Manage PCIe Storage Interface".(SCGCQ01395075)
- when clicking on more actions for any UG drives to make DHS,the options remains as it is in LSA though the operation is done.(SCGCQ01403884)
- WG: Like "Flash Firmware" button in "Update Firmware" page, "Update" button should also have hand symbol & one more issue.(SCGCQ01405822)
- WG: while expanding exiting VD, the expand VD page is not consistent.(SCGCQ01416379)
- Fixed: WG: LSA conf does not contain the perf mode settings options configurable.(SCGCQ01422214)
- WG: Clicking on "Benefits of each MegaRAID Advanced Software Option" in premium feature is not taking to proper link.(SCGCQ01428156)
-.(SCGCQ01428383)
- LSA doesn't allow creating spanned Raid levels with 2 spans using more than 32 drives.(SCGCQ01435647)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01436886)
- WG : "Replace Drive "window needs improvement to look uniform.(SCGCQ01439805)
- when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01440772)
- WG: LSA displays the property Drive Security Capable as 'No' even when security is supported.(SCGCQ01442209)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01443879)
- WG: Confirmation Message has to be changed when more than one drives are converted from JBOD to UG state.(SCGCQ01444672)
- SCGCQ01445818: MR 7.4_Alpha_LSA does not find a server in RHEL 7.4.(SCGCQ01445818)
- WG: LSA times out after "Clear Configuration" command is issued when there is a OFFLINE DG present.(SCGCQ01447788)
- WG: Size for the VD is not updated properly when edited during VD creation.(SCGCQ01447791)
- WG: An extra "." needs to be removed in the event description for "Initialization complete on VD".(SCGCQ01449783)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- WG: Raid 50 Vd Creation fails on unselecting drives after changing span during VD creation.(SCGCQ01309542)
- Coverity Defects - Performance Inefficiencies.(SCGCQ01313878)
- Fixed: Coverity: Class hierarchy inconsistencies.(SCGCQ01318333)
- Client: Coverty defect fixes check-in.(SCGCQ01318336)
- VD size getting increased while creating VD using simple config - Regression.(SCGCQ01341947)
- WG: Once the FW update is completed LSA shows junk character in the notification about firmware flash was successful.(SCGCQ01342536)
- SCGCQ01348082: LSA: Loopback occurs during launch. (intermittent issue).(SCGCQ01348082)
- Expand page is not closed when opened for second time.(SCGCQ01357224)
- "Add Virtual Drives" is disabled when user changes from invalid size to valid size through increment button.(SCGCQ01358299)
- WG: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01375255)
- "Server Profile" displays blank back plane info for ctrl-1.(SCGCQ01375992)
- LSA Client : Foreign Configuration Panel issues with locked and unlocked foreign drives.(SCGCQ01378050)
- DG Actions menu is not shown properly after zooming in when VD's are hidden.(SCGCQ01380663)
- WG: Size range warning is not shown while modifying VD when unit is selected from MB to GB.(SCGCQ01380818)
- LSA Evevnt: Access policy for HIDDEN/Transport is coming as Empty.(SCGCQ01380828)
- LSA Server: User is provided with Hide and Un-Hide option though there is no HIDE performed on a VD.(SCGCQ01380845)
- WG: LSA service crashes on hiding and unhiding DG's with dedicated hotspare.(SCGCQ01380912)
- SCGCQ01383765: Resolve linux server compilation issues.(SCGCQ01383765)
- WG: Reconstruction progress is not refreshed even after the VD is cleared on which reconstruction was happening.(SCGCQ01383800)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01389392)
- WG: Clicking on View server profile just before controller console page loads results in blank page.(SCGCQ01396731)
- WG: "DG degraded notification" is not auto-refreshed after Raid5 VD is brought from offline to online.(SCGCQ01398964)
- WG: When LSA is configured with NAT server, it is shown twice in the Remote Discovery Page.(SCGCQ01401484)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01401546)
- WG: Hidden links present in premium features page.(SCGCQ01412883)
- WG:VD properties details need some changes to look uniform across the application.(SCGCQ01418574)
- WG: Help link for Premium Features is opening in dual tabs.(SCGCQ01428169)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected.(SCGCQ01442107)
- WG:LSA is not showing the options "Pause Patrol Read|Abort Patrol Read" when PR background operation is running.(SCGCQ01442350)
- WG:when user is closing the message box for "Clear Configuration",the "X" symbol is not shown with hand symbol.(SCGCQ01442356)
- LSA service is not working in Linux.(SCGCQ01442733)
- WG: Invalid text"Each_Frehole" present in Pop up of Adding VD to existing Drive group.(SCGCQ01446454)
- WG: "Add Hot Spare" Button is enabled after selecting and deselecting the drives.(SCGCQ01448882)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01448976)
- WG: Event with ID 552 is not updated properly. Information on Mode is empty.(SCGCQ01450725)
- LSA Client: SDS/HBA progress issue.(SCGCQ01459948)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- LSA not giving the Un Hide All Virtual Drives operation when DG contain Hidden and normal VDs.(SCGCQ01308440)
- Coverity Defects fixes for Stream LSA7.3.(SCGCQ01311864)
- LSA7.3: Coverity defect fixes in Server code.(SCGCQ01316168)
- Coverity: Integer handling issues.(SCGCQ01318418)
- LSA Client : IR/IT Multiple Options are allowed in Update Firmware Screen.(SCGCQ01343645)
- Add hot spare page cosmetic issues.(SCGCQ01358219)
- WG:Change button is active even if button appears inactive for "Change personality", fails with an inappropriate notification.(SCGCQ01358967)
- FW last modified time is not coming properly while FW upload.(SCGCQ01359056)
- WG:while editing created vd for CacheCade - SSD Caching Configuration,the write policy tab is coming down.(SCGCQ01380641)
- WG: In "Advanced Configuration" page, Raid settings and Drive Attributes are not numbered properly.(SCGCQ01380646)
- WG: Issues pertaining to "Server is taking long to respond" LSA page.(SCGCQ01383122)
- SCGCQ01395189: WG: "Manage PCIe Storage Interface" displays empty table for MR Ventura controller with profile id 13.(SCGCQ01395189)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01415223)
- WG: Question mark missing in "Erase" confirmation form.(SCGCQ01415923)
- WG: Extra "." (dot) has to be removed in VD Initialization confirmation message and one more cosmetic issue.(SCGCQ01428137)
- WG: Instance Validation is failing for driveGroupConfigurationService-schema.json in MR_Ventura card.(SCGCQ01443739)
- MR7.4_Alpha_LSA crashed when trying to download firmware RHEL 7.4.(SCGCQ01447240)
- LSA Client Refresh issue while making more than one drive(s) offline when RLM is in progress.(SCGCQ01449870)
- WG: No success /failure Notification is shown in server summary page on making a offline drive online.(SCGCQ01451575)
- WG:2 Spans(Modify Span Depth) is showing in "Advance configuraton" page even if their is no PD left for the config.(SCGCQ01452129)
- WG:when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01464425)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01479375)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ00903348)
- LSA should not allow to select the check box of VD and PD simultaneously on xSDS-None mode.(SCGCQ01323724)
- Issue : Instant Secure erase option is seen when FDE and NON-FDE drives are selected.(SCGCQ01326164)
- SCGCQ01332799: Resolve LSA server compilation issue.(SCGCQ01332799)
- LSA conf file not being updated While changing the default port 2463 and 9000 to some other free ports in windows_8.1_x64.(SCGCQ01375895)
- WG: "?" symbol is in the centre of the Drive erase page unlike in other pages.(SCGCQ01383763)
- WG: ESXi server name is not completely visible in Manage Servers page.(SCGCQ01389332)
- WG: UI Enhancement: Hand symbol has to be given for the "Modify VD" icon for better user experience.(SCGCQ01389343)
- Foreign Configuration issues locked and unlocked foreign drives count.(SCGCQ01391010)
- Action successful message needs to be modified for better User experience.(SCGCQ01392057)
- spandepth need one space between span & depth, to look uniform across the application.(SCGCQ01413225)
- Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01423352)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01460076)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01394281)
- WG: Help link for "Activate Features" after providing the Activation key is not working.(SCGCQ01398969)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01424621)
- Added the "?" at the end of instant secure erase. But there no issue related line in more actions panel please find the attached screenshot.(SCGCQ01442352)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01474461)
- 'X' symbol for removing physical drives are not highlighted when the drives are allowed to be removed.(SCGCQ01350436)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)

EnhancementRequests:
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- SLIR3: Change build scripts and makefiles to account for change in directory structure and new name of the library.(SCGCQ00293713)
-.(SCGCQ01389581)
- LSA Page tab name should be changed.(SCGCQ01401514)
-.(SCGCQ01416369)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444590)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- SLIR3: Remove Libsysfs dependency in StoreLibIR3.(SCGCQ00293709)
- Adding Solaris and Sparc X64 bit support in SLIR3.(SCGCQ00922699)
- Change library name to SLIT.(SCGCQ00933175)
-.(SCGCQ01309820)
- LSA Server : [Lenovo Purley] Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01352474)
- HBA nvdata version in Decimal Format in LSA.(SCGCQ01365643)
- WG: Dedicated Hot spare Notification pop-up alignments.(SCGCQ01401505)
- Schedule API changes for time consuming APIs.(SCGCQ01422386)
- MR7.4: Support for FW ER:SCGCQ01389581 in LSA Server.(SCGCQ01428115)
- Update the WebServer Nginx to fix the latest Security Vulnerabilities.(SCGCQ01452493)
- SAS3 Ph8 --- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00729472)
- LSA Client: Handle Progress events without initiating individual API calls.(SCGCQ01416371)
- LSA: Make operation call with query parameter.(SCGCQ01424479)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- WG: Landing page - Graphics improvements.(SCGCQ01401517)
-.(SCGCQ01412749)
- Support for FW ER:SCGCQ01389581 in LSA Client.(SCGCQ01428113)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- LSA7.3: LSA to hide the Empty back plane based on the property field in the LSA.conf file.(SCGCQ01312022)
- LSA: Make operation call with query parameter.(SCGCQ01416374)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- SCGCQ01250909 - [Lenovo Purley] - Retrieve Boot Events and Maintain it as part of Event History.(SCGCQ01291488)
- Client: EPMR12 porting to MR7.3.(SCGCQ01304973)
- Client: Provide pending profile details in LSA.(SCGCQ01331947)
- LSA Server: EPMR12 defect/feature porting to MR7.3.(SCGCQ01307382)
-.(SCGCQ01356193)
-.(SCGCQ01375857)
- WG: In Remote discovery page Self server is always listed in the last.(SCGCQ01378666)
-.(SCGCQ01472631)

CSETActivities:
- VMware LSI Out of Box driver feature reconciliation.(SCGCQ00696009 port of SCGCQ00652798)
- Provide a StoreLibIR2 deb package to work on Ubuntu.(SCGCQ00795333 port of SCGCQ00630108)
- WG: No Units are displayed for Event ID: 545: Information about super cap health.(SCGCQ01297685 port of SCGCQ01291338)
- LSA throws inappropriate error while attempt to start controller firmware upgrade when pinned cache present on controller.(SCGCQ01297819 port of SCGCQ01288364)
- CSCvd88927 - LSA is displaying drives' type string inconsistently for HDD/SSD so it needs to display consistently.(SCGCQ01331599 port of SCGCQ01316465)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336569 port of SCGCQ01313804)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337104 port of SCGCQ01332737)
- Hercules LSA : Schedule CC button does not allow to click on the whole button.(SCGCQ01339214 port of SCGCQ01337027 )
- PR on all drives are not aborted properly until page refresh is done.(SCGCQ01342568 port of SCGCQ01340808)
- No. of steps shown in "Modify Drive Group" page is not correct.(SCGCQ01343651 port of SCGCQ01341921)
-.(SCGCQ01345364 port of SCGCQ01342479)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01345398 port of SCGCQ01332912)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347171 port of SCGCQ01346904)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347220 port of SCGCQ01346908)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347221 port of SCGCQ01346908)
- Cisco_HSW_Validation_LSA: "Simple Configuration" page that appears after creating a simple config is blank.(SCGCQ01347224 port of SCGCQ01345554)
- Cisco_HSW_Validation_LSA: Character limit warning for VD name is not shown while modifying the VD during VD creation.(SCGCQ01347232 port of SCGCQ01345557)
- Cisco_HSW_Validation_LSA: VD Size limit check is not working when user modifies the value of the size.(SCGCQ01350834 port of SCGCQ01346906)
- Cisco_HSW_Validation_LSA: Prepare for removal menu is still displayed even after the option is selected and event is updated.(SCGCQ01350837 port of SCGCQ01338290)
- "%" symbol followed by integer value should not be allowed for the user to enter the size during VD creation.(SCGCQ01350844 port of CGCQ01349556)
- Page scroll doesn't work after VD creation when BG processes on VD are expanded in LSA page.(SCGCQ01351383 port of SCGCQ01349487)
- VD creation fails when a partial VD is added with decimal value & with 1MB strip size to an existing DG.(SCGCQ01354306 port of SCGCQ01348005)
- Security Key provided for importing Foreign Config is not taken by LSA.(SCGCQ01369266 port of SCGCQ01331016)
- Unexpected sense PD messages are flooded in storage log when drive is in spun dwon mode.(SCGCQ01369267 port of SCGCQ01264499)
-.(SCGCQ01375259 port of SCGCQ01373451)
- LSA: Client should not show Unlock drive option if no drives are in locked state.(SCGCQ01378557 port of SCGCQ01331121)
- LSA Server: Windows Make file check-in.(SCGCQ01384621 port of SCGCQ01384618)
- RWC3 Package: Check-in of SL-IT to the package folder.(SCGCQ01384895 port of SCGCQ01384890)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01387017 port of SCGCQ01350435)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389917 port of SCGCQ01389892)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01389918 port of SCGCQ01385340)
- HPE: Un-installation is not removing the folder(s) after performing the Download Diagnostics operation.(SCGCQ01389925 port of SCGCQ01385453)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01391318 port of SCGCQ01389483)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01419753 port of SCGCQ01417215)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ01440910 port of SCGCQ00903348)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275670 port of SCGCQ01275496)
- For phys-schema.json fails for "([0, u'properties', u'isEnabled', u'enum'], 'False ...".(SCGCQ01309844 port of SCGCQ01304900)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01323613 port of SCGCQ01284395)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324865 port of SCGCQ01260226)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01338337 port of SCGCQ01331755)
- Hercules LSA : Cachecade SSD caching should be "enabled" under controller properties.(SCGCQ01339133 port of SCGCQ01337029)
- Hercules LSA : WB and AWB description in LD create page not proper.(SCGCQ01339213 port of SCGCQ01337026)
- User couldn't enter his value in seconds for locating a physical drive.(SCGCQ01344082 port of SCGCQ01332742)
- Cisco_HSW_Validation_LSA: Tooltip for "Simple Configuration" is not shown when other options displays it.(SCGCQ01347225 port of SCGCQ01346851)
- Cisco_LSA: Hyperlink symbol can be shown for "Compare and select" link in Modify Drive Group.(SCGCQ01350847 port of SCGCQ01348107)
- Cisco_HSW_Validation_LSA: Naming convention can be made same across all "Virtual Drive Erase" forms.(SCGCQ01350850 port of SCGCQ01347250)
- cosmetic changes required in "Advanced configuration" page.(SCGCQ01350851 port of SCGCQ01347253)
- DG health is not populated properly in cisco cards.(SCGCQ01350892 port of SCGCQ01349625)
- Virtual Drive Erase form is not closed when it is opened for the second time.(SCGCQ01351381 port of SCGCQ01347243)
- While adding drives to any raid group, Displaying no. of available drives and selected drives can be fine tuned.(SCGCQ01351385 port of SCGCQ01348115)
- Cisco_LSA: "Background Initialization" is misspelled in Event description & one more cosmetic change is required.(SCGCQ01351454 port of SCGCQ01348041)
- In case of FW upload, LSA crash seen with big FW version name.(SCGCQ01351457 port of SCGCQ01338340)
- LSA Client: During the exclusion of the VDs from deletion of one VD leading to the deletion of all the VDs.(SCGCQ01354432 port of SCGCQ01344115)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01387009 port of SCGCQ01379795)
- Hercules:LSA:Observe that instead of "Feedback " it is named as "FeedBack ".(SCGCQ01389091 port of SCGCQ01388943)
- Updated PD firmware version is not reflecting even after LSA refresh.(SCGCQ01392422 port of SCGCQ01382013)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01393239 port of SCGCQ01385340)
- Hercules LSA: "Prepare for removal" feature should be disabled for drives in LSA.(SCGCQ01401490 port of SCGCQ01396735)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- Updating readme file.(SCGCQ01294583 port of SCGCQ01294570)
- For spares-schema instance validation failed for "u'foreign' is not one of [u'NATIVE', u'FOREIGN', u'MIXED']".(SCGCQ01311504 port of SCGCQ01309617)
- LSA server:LSA not showing the server reboot message after profile set.(SCGCQ01316473 port of SCGCQ01316342)
- HSW_testing_LSA : Could not initialize a VD after disabling and enabling again "Initialize" option.(SCGCQ01321339 port of SCGCQ01309783)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337071 port of SCGCQ01332737)
- Cisco_HSW_Validation_LSA: Size range warning is not shown when user is giving value beyond the limit in MB unit.(SCGCQ01352603 port of SCGCQ01352603)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01369283 port of SCGCQ01284395)
- RWC3 Automation Script files check-in.(SCGCQ01385008 port of SCGCQ01384997)
- LSA/RWC Automation batch files check-in.(SCGCQ01386218 port of SCGCQ01386214)
- Hercules:LSA: trying to open in new tab : "Copyright @ 2017 by Avago Technologies. All Rights Reserved" loads blank page.(SCGCQ01389089 port of SCGCQ01386140)
- Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01389588 port of SCGCQ01352480)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01392429 port of SCGCQ01385340)
-.(SCGCQ01392506 port of SCGCQ01391775)
- [Lenovo 17B] - LSA- Selected Firmware version doesn't match while upgrading the FW.(SCGCQ01420040 port of SCGCQ01417199)
- Hercules:LSA: Multiple OLH links are opening when clicked on Advance configuration( IE Browser).(SCGCQ01429992 port of SCGCQ01415979)
- LSA Linux BST Automation scripts.(SCGCQ01466009 port of SCGCQ01447013)
- operations-schema.json fails for "u'percentage' is a required property..." in xSDS mode.(SCGCQ01297806 port of SCGCQ01291332)
- Hercules LSA : Auto refresh not happening on Enclosure push pull with 64 VD's configured.(SCGCQ01297821 port of SCGCQ01276760)
- SCGCQ01309545: WG: Issues pertaining to Event ID: 545: Super Cap Health event has redundant data, missing comma's.(SCGCQ01332698 port of SCGCQ01309545)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01338335 port of SCGCQ01332912)
- Cisco Validation: FW throws an exception while scheduling Consistency check on R1.(SCGCQ01347254 port of SCGCQ01340788)
- VD size is created with improper size when user creates volume by first decreasing and increasing the size in MB unit.(SCGCQ01350833 port of SCGCQ01346860)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01395078 port of SCGCQ01394281)
- Wrong API populated for enclosures operations and schema will fail.(SCGCQ01445408 port of SCGCQ01444689)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01447743 port of SCGCQ01445719)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01458204 port of SCGCQ01443879)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336556 port of SCGCQ01313804)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347125 port of SCGCQ01346904)
- Cisco_HSW_Validation_LSA: Credentials asked during login is not proper when login mode is set to 'Domain Login'.(SCGCQ01347233 port of SCGCQ01341930)
- Hercules-LSA : Updated PD firmware version is not reflecting automatically.(SCGCQ01393283 port of SCGCQ01392496)
- Hercules:LSA: Linux RHEL 6.9: View Event Logs Icon display not proper.(SCGCQ01414738 port of SCGCQ01409445)
- Hercules LSA: Reference to "drive group" while adding logical drive to existing array.(SCGCQ01444720 port of SCGCQ01444670)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01480902 port of SCGCQ01313228)
- Fixed: Drive group Migration was disabled with NVME drives DG.(SCGCQ01313228 port of SCGCQ01289586)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324864 port of SCGCQ01260226)
- Spare URI does not respond on iMR Invader.(SCGCQ01378677 port of SCGCQ01376605)
- [PA_2017B_SDV_Lenovo_x3650 M4_Storage] LSA tool update FW Image (oss: 75871) Failed for N2225 SAS HBA(Outback-2) card.(SCGCQ01408778 port of SCGCQ01408626)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411632 port of SCGCQ01397546)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01417213 port of SCGCQ01415347)
-.(SCGCQ01417223 port of SCGCQ01375862)
- LSA: Make operation call with query parameter.(SCGCQ01423429 port of SCGCQ01416374)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01427110 port of SCGCQ01419325)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01345397 port of SCGCQ01331755)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01354345 port of SCGCQ01321474)
- Hercules LSA: Default write policy for R1 CC VD should be WB instead of WT.(SCGCQ01401352 port of SCGCQ01397557)
- [Lenovo 18A] 110340 - [PA_2017B_SDV_Lenovo_Red_Reno_Storage] Use LSA to configure M5225 and it fail to create VD's from LSA.(SCGCQ01424599 port of SCGCQ01421451)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline.(SCGCQ01443687 port of SCGCQ01442554)
- Phase 2 changes for Linux VBAS automation script.(SCGCQ01460081 port of SCGCQ01455968)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
- CSCvd28635: LSA throws inappropriate error while attempt to start patrol read on virtual drive with SSDs.(SCGCQ01319398 port of SCGCQ01284997)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01332824 port of SCGCQ01325783)
- To resolve the merge conflict.(SCGCQ01348161 port of SCGCQ01348057)
- Port Info disappears on doing Drive push pull.(SCGCQ01404636 port of SCGCQ01379323)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444595 port of SCGCQ01444590)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)


3.023.000.000 - Moderate Impact
-------------


2.090.000.000 - Moderate Impact
-------------
Enhancement:
- Added Support for ThinkSystem HBA and RAID adapters


2.085.000.000 - Moderate Impact
-------------
- Fixed issue where logs incorrect when remove/insert hdd (SCGCQ01246085)
- Fixed Invalid Server Id as part of event, if server is not in network (SCGCQ01261779)
- Fixed issue where moving PD from slot 0 to another slot, PD slot ID usually still show slot 0 and slot format (SCGCQ01264554)
- Fixed issue where external enclosure serial number in not consistent between LSA, MSM and storcli (SCGCQ01268914)
- Fixed issue where LSA does not list Raid 10 as configurable raid level under configuration service uri when drive mixing is allowed (SCGCQ01037806)
- Fixed issue where Incorrect configurable Volume sizes displayed in LSA for Raid 0(SCGCQ01039518)
- Fixed issue where LSA is not un-installing through the Uninstall-LSA option through Windows All Programs (SCGCQ01039698)
- Fixed issue where VD Properties in LSA was not getting populated for default settings (SCGCQ01043610)
- Fixed issue where controllers/{id}/spares is not populated correctly (SCGCQ01056900)
- Fixed issue where LSA displays only 2 enclosures when four enclosures are connected. (SCGCQ01061548)
- Fixed issue where Enclosure more properties displays "Number of Voltage Sensors" as "0" (SCGCQ01063504)
- Fixed issue where On Number of Temperature Sensors observe that temperature mentioned has 65535 C. (SCGCQ01063924)
- Fixed issue where When the PD is in GHS state LSA is displaying the Prepare for removal option (SCGCQ01064282)
- Fixed issue where LSA does not display the access policy 'hidden' in View Event Logs. (SCGCQ01065622)
- Fixed issue where schedule patrol -read throws an error 'Invalid URI parameter' when user clicks on Finish button. (SCGCQ01066126)
- Fixed issue where Unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01066154)
- Fixed issue where LSA crashes while trying to add a VD to the RAID 00 drive group. (SCGCQ01069405)
- Fixed issue where Simple configuration fails while trying to create VD using SSD Drive (SCGCQ01069412)
- Fixed issue where compared with MSM values of "Date of manufacture" and "Type" is varying. (SCGCQ01069493)
- Fixed issue where Unable to clear or import partial foreign configuration from LSA. (SCGCQ01069580)
- Fixed issue where Ventura: LSA still displays clear button as active even after successfully importing foreign configuration. (SCGCQ01069616)
- Fixed issue where IR3 Events logs are listed reverse sequence in "View Event logs" (SCGCQ01069847)
- Fixed issue where LSA Drive Tab PD "Unconfigured Good" count does not automatically refresh when we Move UG PD to JBOD and vice versa(SCGCQ01069852)
- Fixed issue where Modifying the VD during the VD creation results in option for user to allow more than one cachecade VD, Creation fails (SCGCQ01069898)
- Fixed issue where Instance validation fails for Clear Drive, Stop Clear Drive, Prepare & Undo prepare for removal due to "parameters":{}" (SCGCQ01070441)
- Fixed issue where Instance validation fails for Manage Power Save Settings, Controller PUT operation (SCGCQ01070690)
- Fixed issue where Instance Validation fails for Schedule Consistency Check (SCGCQ01070739)
- Fixed issue where Instance Validation fails for Physical Devices GET (IT controller) (SCGCQ01074960)
- Fixed issue where Server not found warning message is displaying repeatedly one over the other (SCGCQ01075026)
- Fixed issue where Backplane information not displayed under view server profile (SCGCQ01075841)
- Fixed issue where if config cleared during reconfiguration, progress bar does not clear(SCGCQ01075843)
- Fixed issue where hide on DG is not automatically updating the access policy of VDs (SCGCQ01076009)
- Fixed issue where LSA Crashes when we run API performance Script ususally when performing PD Operations GET in Large config (240 PD)(SCGCQ01076023)
- Fixed issue where "Controller Info" of LSA displays driver version of the Gateway server instead of displaying the driver of Vmware server (SCGCQ01076031)
- Fixed issue where "Application Version" in server profile page is displayed as "LSA Server null". (SCGCQ01076146)
- Fixed issue where there were multiple extra columns in PD tab (SCGCQ01077452)
- Fixed issue where the Physical devices are listed in Decreasing order of Device ID instead of ascending order in drive tab (SCGCQ01077563)
- Fixed issue where firmware update does not happen in the Direct agent system from Gateway (SCGCQ01077677)
- Fixed issue where Manage Power save settings with input of " 1 hour" fails with an error " Input Parameters are Invalid" (SCGCQ01078509)
- Fixed issue where Managed Server page provides option of adding gateway server from which we have already logged in to manage server (SCGCQ01078524)
- Fixed issue where Feedback is displayed as FeedBack in LSA. (SCGCQ01079092)
- Fixed issue where After adding server in Manage Server Page intermittently get a junk screen  (SCGCQ01079698)
- Fixed issue where back button does not work in case of Advanced Configuration During VD Creation (SCGCQ01079912)
- Fixed issues pertaining to "Set Patrol Read Properties" Number of PD Count allowed for patrol read (SCGCQ01080265)
- Fixed issue where after logging out from server that is been managed. Clicking Server again in managed server page LSA asks for credentials (SCGCQ01080448)
- Fixed issue where Instance Validation fails for PROGRESS related Operations (SCGCQ01082194)
- Fixed issue where Instance validation fails for "/controllers/0/operations/security" URI : Controller Operation POST (SCGCQ01082618)
- Fixed issue where inappropriate error message is displayed in LSA on flashing fw on IT Intruder (SCGCQ01082897)
- Fixed issue where LSA page does not automatically refresh when PD moved from UG bad to UG Good SS page, CC page does not give option (SCGCQ01083060)
- Fixed issue where on clicking save button on mail server page its shift to Alert Settings without saving that page. (SCGCQ01083063)
- Fixed issue where LSA does not show the default power save mode time set in mfc (SCGCQ01083106)
- Fixed issue where after adding server the managed server list, then logging out, new server cannot be logged into. (SCGCQ01083226)
- Fixed issue where LSA service is not present in the Windows services after downgrading LSA. (SCGCQ01084774)
- Fixed issue where Event Response is giving Default Write Policy: abc (SCGCQ01043609)
- Fixed issue where Sending Invalid HTTP verb in the request for an URI fails with 404 instead of 405 (SCGCQ01059216)
- Fixed issue where texts linked to the health icons "optimal", "critical", "needs attention", in server summary page Should be clickable (SCGCQ01063432)
- Fixed issue where LSA still displays physical disk actions and properties menu when no pd is selected after sorting from Enclosure/slot. (SCGCQ01063524)
- Fixed issue where Instance Validation fails for Simple Configuration POST (SCGCQ01064737)
- Fixed issue where consistency check Schedule parameters is available even after selecting the "Disable" from the Consistency check mode (SCGCQ01069825)
- Fixed issue where LSA not accessible through Chrome browser Version 48.0.2564.109 m (SCGCQ01078618)
- Fixed issue where while initiate ISE against 3rd party locked UG drive, XHR_Header code says "POST 200" but XHR_Response says "Er 77" (SCGCQ01080402)
- Fixed inconsistency between the VD properties displayed in STORCLI when compared with other Apps. (SCGCQ01081145)
- Fixed issue where LSA doesn't get updated without a service restart on Vmware server with IR3 controller. (SCGCQ01081324)
- Fixed issue where matching error description is not shown by client when there is a session already active during login. (SCGCQ01063542)
- Fixed issue where LSA login attempt failed for Vmware Server (SCGCQ01064784)
- Fixed issue where 002.010.000.000 build (Gateway & Standalone) is unable to discover server (SCGCQ01069396)
- Fixed issue where replace drive table does not have device Id column (SCGCQ01075112)
- Fixed issue where LSA does not update the data automatically when Delete VD is performed. (SCGCQ01079635)
- Fixed issue where RWC3-LWM (Windows) is unable to send mail to SMTP (SCGCQ01173361)
- Fixed issue where Ventura IT drive push and pull needs services restart to update the count (SCGCQ01066048, Port of SCGCQ01064904)
- Fixed issue where LSA Allows JBOD Drive having OS to be converted to UG drive, doesnt notify the user on the OS present on JBOD (SCGCQ01067253, Port of SCGCQ01052412)
- Fixed issue where LSA displays "error:Not all values are set successfully" while trying to save power save settings on IMR Ventura. (SCGCQ01067711, Port of SCGCQ01057457)
- Fixed issue where LSA shows blank screen after log in with mutiple controller in the setup (SCGCQ01069360, Port of SCGCQ01068813)
- Fixed issue where intermittent update Ventura firmware hang using LSA ( StorCLI is OK ) (SCGCQ01069565, Port of SCGCQ01038421)
- Fixed issue where user unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01070807, Port of SCGCQ01066154)
- Fixed issue where all the events are not getting downloaded while downloading log from LSA (SCGCQ01145261, Port of SCGCQ01139334)
- Fixed issue where no error message is displayed while importing secure EPD through wrong key (SCGCQ01066088, Port of SCGCQ01063911)
- Fixed issue where user unable to clear or import partial foreign configuration from LSA. (SCGCQ01085466, Port of SCGCQ01069580) 

2.030.000.000 - New Function Only/No fixes
-------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved

StorCLI command line tool for anyos (For Linux)



StorCLI (Command Line) Utility for Storage Management

Adapters Supported:
  - ThinkSystem 430-8i PCIe 12Gb HBA
  - ThinkSystem 430-16i PCIe 12Gb HBA
  - ThinkSystem 430-8e PCIe 12Gb HBA
  - ThinkSystem 430-16e PCIe 12Gb HBA
  - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
  - ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-16i 8GB  Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  - ThinkSystem RAID 930-4i 2GB Flash Flex Adapter
  - ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 
  - ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-16i PCIe 12Gb Adapter
  - ThinkSystem RAID 530-8i Dense Adapter
  - ThinkSystem RAID 530-4i 4GB Flex Adapter
  - ServeRAID M1215 SAS/SATA Controller for Lenovo System x (46C9114)
  - ServeRAID M1210 SAS/SATA Controller for Lenovo System x  
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x880 X6 Compute Node
  - ServeRAID M1210e SAS/SATA Controller for Lenovo x240 M5 Compute Node
  - ServeRAID M5225-2GB SAS/SATA Controller
  - ServeRAID M5210e SAS/SATA Controller for System x
  - ServeRAID M5210 SAS/SATA Controller
  - ServeRAID M5215 SAS/SATA Controller (00JX142)
  - ServeRAID M5115 SAS/SATA Controller (90Y4390)
  - ServeRAID Lenovo Storage Expansion Node (65Y8588)
  - ServeRAID M5110 SAS/SATA Controller for Lenovo System x (81Y4481)
  - ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
  - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)

NOTE TO SERVICE - Reference RETAIN #N/A

007.1022.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects :
 - PERCcli Help text is missing description for "Lane Information"(SCGCQ02150899) 
 - Add NVMe width comments to mr.h(SCGCQ02146846) 
 - Fix API changes done for NVMe readiness(SCGCQ02142981) 
 - CLI returns "success" when attempting to set DS3 or DS4 to enabled(SCGCQ02116380) 
 - CLI returns "success" when attempting to change the H840 controler to eHBA personality.(SCGCQ02114332) 
 - CLI returns wrong error code upon failure(SCGCQ02084966) 
 - HPE shenandoah: storcli crashes during show command when DGs present(SCGCQ02065695) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02045324) 
 - ROP version not displayed with latest ROP version SCGCQ02035462(SCGCQ02041094) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option(SCGCQ02035152) 
 - retentiontest command is successfully triggering BBU test on Shenandoah controller(SCGCQ02021398) 
 - Storclio (007.0911.0000.0000) detailed help file doesn't have " locale " option for flashing FW in Dual/Active & Backup mode.(SCGCQ02012025) 
 - hot spare reference in Add Spare command output(SCGCQ01897463) 
 - Shenandoah:Strocli show all output return failure but generates output(SCGCQ01929191) 
 - Junk message "STR_JBOD_OBJ" is displayed in the output of storcli /c0 show JBOD command.(SCGCQ01932770) 
 - Shenandoah_StorCLI: No legend presend for VD Delete Failure(SCGCQ01936811) 
 - Shenandoah_StorCLI:Setting Unmap=OFF gives success for a LD when unmap is not supported and not enabled on that LD(SCGCQ01940291) 
 - Set WrCache= WB ,says success even though VD is in WT.Proper warning message should be given to the user(SCGCQ01940296) 
 - Legend missing for LD BGI resume/pause commands(SCGCQ01940347) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945551) 
 - Shenandoah_StorCLI: Storcli crashes on checking LD preserved cache info(SCGCQ01955069) 
 - CLI is showing the incorrect OS version(SCGCQ01956276) 
 - Unified StorCLI : Add extra space to CBB header(SCGCQ01956678) 
 - PH10 Alpha - StorCLI throws "0 Failed 32782 Failed to get PD Info" when /c0 show executed in EFI(SCGCQ01960322) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01961527) 
 - supported personalities has blank value(SCGCQ01965370) 
 - storcli faults for enclosure show command(SCGCQ01985815) 
 - MR7.10_PA1: Storcli binaries for RHEL/SLES OS is not present for ARM(SCGCQ02006374) 
 - NVMe drive displays incorrect information with IT card(SCGCQ02009852) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02016762) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for snapdump commands.(SCGCQ02018073) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02018134) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02018135) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02018140) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02018333) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02019740) 
 - Instance Validation Failed between " controller-lane-show-schema.json" and "/call/lnall show"(SCGCQ02019746) 
 - Pending Image details are not populated after FW upgrade and downgrade.(SCGCQ02024065) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all "(SCGCQ02032911) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02034493) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02035370) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure(SCGCQ02053910) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02061340) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show_all"(SCGCQ02062957) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02064836) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02064839) 
 - PH11 Alpha - StorCLI 'show file' command throws segmentation fault for complete flash image in FreeBSD(SCGCQ02065691) 
 - Storcli: No schema files for htbparams commands.(SCGCQ02065698) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02065734) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02067575) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02069817) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02070951) 
 - Aero (DBU PA2): Storcli: No syntax error displayed for "storcli mronly" command.(SCGCQ02072746) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02076923) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02076931) 
 - htbparams help output needs update.(SCGCQ02077156) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02078437) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02078513) 
 - Recon command (./storcli /cx set recon) is throwing syntax error.(SCGCQ02081415) 
 - storcli /c0/ex/s23,24 show patrol read doesnt not show error for slot 24 (Invalid Slot)(SCGCQ02082142) 
 - Aero (DBU PA2): Storcli show detailed help does not list "show all " command.(SCGCQ02082303) 
 - Aero (DBU PA2): Storcli: Get rttdump detailed help shows syntax error.(SCGCQ02082460) 
 - Storcli: Incorrect message while executing "storcli64.exe /c0/v0 del discardcache"(SCGCQ02083828) 
 - Failure status for /call/sall and /call/eall/sall command.(SCGCQ02084549) 
 - Storcli: Error in /c0/f0 command output.(SCGCQ02089892) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02090770) 
 - Storcli doesn't exit with controller status message after doing OFU.(SCGCQ02091548) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02096774) 
 - Aero (DBU PA3): Storcli: FW hits Megamon while executing storcli in EFI shell when EFI Driver is unloaded.(SCGCQ02097647) 
 - StorCLI crashes for 'storcli J command(SCGCQ02117749) 
 - Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) 
 - Controller Health Status not consisten across applications(SCGCQ02182243) 
 - Perccli does not enable Power Save mode for UG & HS type 1 & type 2.	(SCGCQ02125408) 
 - StorCLI: Delete config failure message need correction(SCGCQ02086726) 
 - StorCLI:VD reference in Delete preserved cahce command output -Branding(SCGCQ02083992) 
 - VD reference in set JBOD command output message(SCGCQ02078507) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02075242) 
 - STORCLI: Show command output having wrong legend for Slt for oem Hercules(SCGCQ02067616) 
 - Grammatical error in Perccli message(SCGCQ02065513) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02045967) 
 - VD legend missing in the legend for Foreign config show all output(SCGCQ02016798) 
 - Hercules:Shenandoah:Transformation is coming as Reconstruction , while migrating the Raid 1 to Raid 5 .(SCGCQ01897468) 
 - Mis-spelled words in StorCli's Help(SCGCQ01898853) 
 - Hot spare reference in storcli.exe /cx/ex/sx show all command output(SCGCQ01905019) 
 - Reference to VD in storcli.exe /c1/jbodall delete command output(SCGCQ01905077) 
 - Fixing coverity issues Removing dead code and Out of bound access(SCGCQ01924504) 
 - Shenandoah_StorCLI: HotSpare reference in Add VD Command output(SCGCQ01936887) 
 - storcli /c0 show events output not listing the Event ID's(SCGCQ01940290) 
 - Shenandoah_StorCLI:Hot spare reference in storcli64 /cx show/set restorehotspare command outputs(SCGCQ01940437) 
 - Shenandoah_StorcLI:Drive Group reference in Add dedicated spared drive command in CLI(SCGCQ01955167) 
 - Intel NVMe drive "Model Number" displayed incorrect under Device Attributes(SCGCQ01957949) 
 - Aero: Segmentation Fault in storcli /c0 show all(SCGCQ01996444) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02006450) 
 - storcli gives error when the lane configuration is set as X8	(SCGCQ02007152) 
 - MR_7.10_Storcli: No schema file for controller unmap commands(SCGCQ02016749) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-restorehotspareoninsertion-schema" and "set restorehotspare"(SCGCQ02016765) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-properties-schema" and "/c0 show"(SCGCQ02016768) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02016771) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-autoconfig-schema.json" and "show autoconfig" JSON output.(SCGCQ02018227) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02018277) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02018305) 
 - MR_7.10_Storcli: Instance Validation Failed between "system-schema.json" and "./storcli show" and "show all" JSON output.(SCGCQ02018313) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02018327) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02019729) 
 - Storcli displays drive state as UBad instead of UBad (unsupported)(SCGCQ02031615) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02040779) 
 - Fixing coverity issues Fixing resource leaks(SCGCQ02043601) 
 - Storcli help file should show the expand size format.(SCGCQ02047109) 
 - Updating the storcli schema mapping document	(SCGCQ02050586) 
 - PH11 Alpha - StorCLI - Parse error observed for command 'StorCLI J' while validating Jason(SCGCQ02053030) 
 - JSON-SCHEMA : IT-Controller Json-schema validation erros in MR_SAS_Unified_StorCLI_7.10(SCGCQ02053914) 
 - Aero: Storcli : Storcli crashed when Firmware upgrade tried on Sea controller(SCGCQ02060276) 
 - Aero (DBU PA2): Storcli: JSON readme file does not have complete VD and PD support list.(SCGCQ02061328) 
 - Instance Validation Failed bw "enclosure-drive-detailed-schema.json" & "/call/eall/sall show all"(SCGCQ02062958) 
 - PH11 Alpha - StorCLI - Compare linkspeed command failed for 6Gbps link(SCGCQ02063932) 
 - Invalid aero controllers are not displayed with apt message in driver less mode(SCGCQ02065581) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02072448) 
 - Aero (DBU PA2): Storcli: /cx/mx command does not mention about "Auto" settings.(SCGCQ02082208) 
 - Storcli: Force is mentioned as optional in snapdump delete command.	(SCGCQ02083822) 
 - Help of /cx/px compare command needs update and /cx/px reset ? shows syntax error.(SCGCQ02084752) 
 - No proper legends in /fall output.(SCGCQ02100491) 
 - Aero (DBU PA3): Storcli: Incorrect schema mapping for "/cx set autoconfig " command.(SCGCQ02101558) 
 - Storcli: OCR helps needs update.(SCGCQ02113241) 
 - Storcli: No proper description of set and show sesmultipathcfg.(SCGCQ02113358) 
 - StorCLI: File sync issue with rel and dev stream for MR 7.10	(SCGCQ02116806) 
 - Storcli script stops with error "can't fork: Cannot allocate memory"	(SCGCQ02184427) 
 - IT- CLI treats EID and Partner Device ID as two different enclosure during pd info command and fails.(SCGCQ02185442) 
 - "/eall show" will not show enclosure details if it is in multitpath & no drives connected.(SCGCQ02186022) 
 - Legacy messages present with create and rekey of securitykey on controller(SCGCQ01581843) 
 - Shenandoah_StorCLI:VD reference in CLI outout for Firmware update command failure case(SCGCQ02083991) 
 - StorCLI: VD listing for c0 show and vall show is toggled	(SCGCQ02078936) 
 - output information for link configuration is displayed incorrectly(SCGCQ02073046) 
 - Drive Groups is shown instead of arrays in show all command(SCGCQ02048660) 
 - Help is not updated for get snapdump without ID option.(SCGCQ02046991) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02040783) 
 - Adding debug logs to Mfi files(SCGCQ01891583) 
 - MR7.8_Storcli: Storcli fails to install on ARM server with Missing Maintainer message(SCGCQ01919830) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01921258) 
 - Unified StorCLI 7.9 : Fixing coverity issues - Dead code,resource leaks,and memory corruption - Part 1(SCGCQ01925503) 
 - Incorrect help option for set autoconfig in StorCli's Help(SCGCQ01932035) 
 - Unmap enabled property is shown in VD detailed properties when controller does not support unmap	(SCGCQ01932177) 
 - Unified StorCLI - Aero : "FullFlashImage" environmental variable component stamp change(SCGCQ01963738) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON output.(SCGCQ02018322) 
 - MR_7.10_Storcli: Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show"(SCGCQ02024327) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034064) 
 - Aero IT - PA1 - StorCLI - BIOS verion not displayed with flash file using 'show file' command(SCGCQ02034490) 
 - failure in StorCLI enclosure show status	(SCGCQ02040640) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02042106) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02043610) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044777) 
 - Port information is not displayed for Vses Backplane(SCGCQ02053070) 
 - "c0 delete ?" does not list snapdump command.(SCGCQ02053639) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02062834) 
 - Aero (DBU PA2): Storcli: Instance Validation Failed bw "vd-operations-migrate-schema.json" & "start_migrate"(SCGCQ02062960) 
 - Aero (DBU PA2): Storcli: Result shows blank for "resume patrolread" failure case.(SCGCQ02064795) 
 - Fail to set the linkconfig .	(SCGCQ02070797) 
 - Storcli /c2 set linkconfig conname=c0,c1 configid=14 returns invalid syntax error(SCGCQ02070953) 
 - Aero DBU PA2 : Syntax error is seen in storcli /cx(x|all	(SCGCQ02077085) 
 - Aero (DBU PA2): Storcli: Syntax error for "/c0 download psoc/efibios/cpld/fcode ?" download commands.(SCGCQ02077175) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02078409) 
 - Incorrect string displayed in show command in FreeBSD OS(SCGCQ02082949) 
 - MR_7.10_Storcli: "storcli show file=filepath" command shows failure status.(SCGCQ02085630) 
 - PCI Linkconfig configid status is failure, even though it was set(SCGCQ02086669) 
 - Storecli_Aero: Using latest storecli show file command "Aero-DVT -HBA 9500-16e" board output version number shows wrong.(SCGCQ02089427) 
 - Libmods changes for defect SCGCQ02062957(SCGCQ02089862) 
 - Help update for "add vd cachevd" command as Normal VD is created with failure status.(SCGCQ02091155) 
 - Preserved cache help file shows a mismatch in command and the convention.(SCGCQ02106218) 
 - Aero DBU PA4 : Storcli doesn't show the convention details properly for storclio /cx/px show command(SCGCQ02113377) 
 - Aero (DBU PA4):Storcli: Syntax error for /c0 show AliLog ?(SCGCQ02113506) 
 - Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) 
 - Misleading error msg "157 Failed Cannot mix unmap and non-unmap physical drives in same array"(SCGCQ02151484) 
 - Cryptographic erase field is shown "yes" but crypto erase fails.(SCGCQ02175346) 
 - Device Type for non-UBM backplanes are being shown as Enclosure instead of Backplane(SCGCQ02101095) 
 - Multiple status messages are displayed in the output	(SCGCQ02073042) 
 - Controller health status is shown as optimal when megacell cable is disconnected.(SCGCQ02021393) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"(SCGCQ01889700) 
 - Shenandoah_StorCLI:32 Binary crashes on giving invalid input to the command storcli.exe /c0/jbod0 show(SCGCQ01905831) 
 - For NVMe drive use the term NVMe instead of PCIe(SCGCQ01923119) 
 - PD show all command displays SSD weargauge details , which is not required.(SCGCQ01927864) 
 - MR_7.10_Storcli: Junk character in error message while creating SED vd with regular HDD drives.(SCGCQ02016701) 
 - MR_7.10_Storcli: Incorrect command syntax mentioned in Schema_mapping_list.xlsx file for "/cx set autoconfig" command.(SCGCQ02018097) 
 - Instance Validation Failed between "vd-operations-bgi-schema.json" and "/call/v1 show bgi " and "show init".(SCGCQ02035551) 
 - Storcli shows incorrect output for delete events command(SCGCQ02045816) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02048150) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053923) 
 - StorCLI displays expansion as successful even when there is no free space to expand(SCGCQ02057361) 
 - Instance Validation Failed between "controller-patrolread-schema.json" and "/call resume patrolread"(SCGCQ02062942) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02063689) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02064120) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02064828) 
 - Aero (DBU PA2): Storcli: Inconsistency in "add vd" command syntax.(SCGCQ02082196) 
 - Details are displayed twice in "/cx/bbu start ? "(SCGCQ02100905) 
 - Storcli: set termlog shows [=on|off] mentioned as optional.(SCGCQ02113353) 
 - CLI is missing the JBOD PD size for SysPDs when using the "show jbod" command(SCGCQ02132277) 
 - Percli returns “invalid arguments" when trying to create a VD using some PDs already configured in a VD and some U(SCGCQ02122169) 
 - Topology information missing from Storcli output(SCGCQ02048612) 
 -	(SCGCQ02040597) 
 - Unified StorCLI: StorCLI does not return the return code from SLIT/SLIR3 to explorer/command processors(SCGCQ01925156) 
 - Virtual drive reference in Delete Preserved cache command output(SCGCQ01940333) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940805) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01948579) 
 - Shenandoah : Firmware receives incorrect erase type for sanitize crypto erase option(SCGCQ01958564) 
 - Storcli shows BBU present instead of EnergyPAck in HWcfg for StorCLI /cx show all output.(SCGCQ01985592) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Sea (3816_Eval) IT Controller(SCGCQ02008219) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for errorcounters commands.(SCGCQ02018078) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02030652) 
 - There is no error message for smart drive failure command.(SCGCQ02040645) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02046036) 
 - JSON Schema : Updating the schema list with Virtual drive command set(SCGCQ02057360) 
 - storecli_Aero:In linux error message observed in the show output.(SCGCQ02057699) 
 - Checking in JSON schemas(SCGCQ02061305) 
 - Junck character displayed in Virtual SES phy id, when we query phyerror counter for enclosure.(SCGCQ02094970) 
 - Aero (DBU PA3):Storcli: Help of /cx/px reset does not mention about option hard reset.(SCGCQ02100896) 
 - BBU show detailed help does not list "show learn " command.(SCGCQ02100915) 
 - Storcli: Instance Validation Fails for all /call/e65/sall commands where "e65 is not found".(SCGCQ02101564) 
 - Storcli: Remove Nytro supported options in "/cx [start] flush|flushcache [cachecade | ALL]" help.(SCGCQ02113484) 
 - MR7.10 cli return mesg. typo after ctrl restart then immediately running storcli64 /c0 show.(SCGCQ02113833) 
 - Storcli: /c0 compare help lists /c0/px compare command.(SCGCQ02124246) 
 - Serial number not displayed fully in 7.10 StorCLI 007.1017.0000.0000 for IT Controller(SCGCQ02173789) 
 - Hide BBU details from the command "storcli /c0 show alilog" for HPE(SCGCQ01937259) 
 - Disk group is displayed instead of array on HPE platforms(SCGCQ01965366) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02016758) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02024740) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02034471) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02035437) 
 - Instance Validation Failed for "/call show and /call show all".(SCGCQ02101432) 
 - Instance Validation Failed bw "drive-group-detailed-schema.json" and "/call/dall show all".(SCGCQ02101513) 
 - Autoconfig options are allowed to set with latest storcli(SCGCQ02053643) 
 - Unified StorCLI Phase 10 : Image checksum should not be performed for aero images(SCGCQ01942200) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02035439) 
 - Fixing coverity issues Fixing resource leaks and explicit NULL dereferencings(SCGCQ02042242) 
 - Unified StorCLI : Fixing resource leaks - Part 1(SCGCQ02042513) 
 - Updating Schema mapping doc and fixing validation errors	(SCGCQ02057434) 
 - Storcli: Instance Validation Fails for vd-bootdrive-schema.json and vd-unmap-schema.json.(SCGCQ02101568) 
 - Aero_storecli:Using latest storecli firmware download fail with noreset option.(SCGCQ02101570) 
 - Aero DBU PA4 : Syntax error is seen for the command - storclio.efi /cx/px set state ?(SCGCQ02113123) 
 - PD info incorrectly shows Number of Blocks for >TB drives(>3TB in my case(SCGCQ02183653) 
 - CLI is returning "success" when attempting to set bios mode to Ignore Errors.(SCGCQ02121017) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02084833) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01892288) 
 - Initialize the MFG structure(SCGCQ01901166) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Aero (3916_Eval) IT Controller(SCGCQ02021194) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02040756) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02042296) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047100) 
 - Updating storcli-cmd-list.xlsx for Drives(SCGCQ02056199) 
 - Message with Incorrect controller object is displayed while setting SSD Caching on VD(SCGCQ02057085) 
 - Storcli displays grammatically incorrect message in detailed help file.(SCGCQ02097641) 
 - MR_7.10: Storcli: Property is shown as SCSI Umap instead of SCSI Unmap.(SCGCQ02101572) 
 - Storcli: /c0 show detailed command does not list /cx/px show phyerrorcounters and /cx show vpd.(SCGCQ02113262) 
 - Aero (DBU PA4):Storcli: Incorrect description of "/c0/v0 show migrate" command.(SCGCQ02113511) 
 - Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) 
 - Storcli: Junk character in PD start locate command description.(SCGCQ02125654)
 - Storcli doesn't exit with controller status message after doing OFU.	(SCGCQ02101069 port of SCGCQ02091548) 
 - perccli /c0 show all lists topology without any DG's present	(SCGCQ02085925 port of SCGCQ01998332) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - Libmods: HPE serial number display(SCGCQ02062634 port of SCGCQ01885657) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979616 port of SCGCQ01979599) 
 - Hide "set pdfaileventoptions" command from CLI Help(SCGCQ01892551 port of SCGCQ01880722) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01911777 port of SCGCQ01856544) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01927583 port of SCGCQ01106982) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945574 port of SCGCQ01945551) 
 - storclio command not working to update FW on SATA disk(SCGCQ01963953 port of SCGCQ01918814) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01963954 port of SCGCQ01937410) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964173 port of SCGCQ01955389) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01966163 port of SCGCQ01892560) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01982925 port of SCGCQ01979483) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01985486 port of SCGCQ01893074) 
 - Enable iMR advanced debug dump(SCGCQ02035300 port of SCGCQ01873124) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02074659 port of SCGCQ02072353) 
 - HDET:Libmods-Boot device should be presented as /dev/sda in Linux operating system during installation and post installation	(SCGCQ02082198 port of SCGCQ02046182) 
 - HDET: Boot device should be presented as /dev/sda in Linux operating system during installation and post installation(SCGCQ02082199 port of SCGCQ02016712) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02085669 port of SCGCQ02045967) 
 - storclif /cx delete colinfo ? shows syntax error	(SCGCQ02124654 port of SCGCQ02124492) 
 - PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02128167 port of SCGCQ02119004) 
 - Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02142248 port of SCGCQ02140878) 
 - Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02145876 port of SCGCQ02140859) 
 - PERCCLI to support creation of VD with WB policy for PERC8 MR(SCGCQ01892550 port of SCGCQ01891650) 
 - MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+	(SCGCQ02139866 port of SCGCQ02066386) 
 - Libmod changes for SCGCQ02090770(SCGCQ02097658 port of SCGCQ02090770) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02075280 port of SCGCQ02072353) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.	(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli shows incorrect output for delete events command(SCGCQ02046875 port of SCGCQ02045816) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01979535 port of SCGCQ01979483) 
 - enhance warning message for personality switch indicating interruption could cause controller to be unstable(SCGCQ01892552 port of SCGCQ01892549) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"	(SCGCQ01906745 port of SCGCQ01889700) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01925211 port of SCGCQ01196785) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929137 port of SCGCQ01224857) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01963960 port of SCGCQ01923119) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01963964 port of SCGCQ01921258) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01965193 port of SCGCQ01961527) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965209 port of SCGCQ01949495) 
 - supported personalities has blank value	(SCGCQ01971366 port of SCGCQ01965370) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977028 port of SCGCQ01948579) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979617 port of SCGCQ01979599) 
 - WBSup abbreviation defined twice when running perccli /cX show profile(SCGCQ01995022 port of SCGCQ01993282) 
 - spell mistake in start diag operation failure(SCGCQ01998963 port of SCGCQ01998330) 
 - Proper message to be given on VD creation with wb option while Battery not connected/Failed(SCGCQ02028787 port of SCGCQ01972504) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02028810 port of SCGCQ02008676) 
 - Enable iMR advanced debug dump(SCGCQ02035289 port of SCGCQ02030908) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02085609 port of SCGCQ02084833) 
 - Flashing of Completeflash fails on Sea IT controller(SCGCQ02139848 port of SCGCQ02139780) 
 - Storcli: "Ctrl" legend not mentioned.(SCGCQ02150640 port of SCGCQ02146822) 
 - storcli -help missing the verbose option	(SCGCQ02160908 port of SCGCQ02158600) 
 - MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02168183 port of SCGCQ02165933) 
 - Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02179296 port of SCGCQ02174296) 
 - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180519 port of SCGCQ02180495) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.	(SCGCQ02047079 port of SCGCQ02024740) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - storcli faults for enclosure show command(SCGCQ01986423 port of SCGCQ01985815) 
 - storclio command not working to update FW on SATA disk(SCGCQ01922919 port of SCGCQ01918814) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964153 port of SCGCQ01955389) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01965185 port of SCGCQ01413253) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965210 port of SCGCQ01949503) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01966261 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01985558 port of SCGCQ01892560) 
 - Snapdump unsupported commands for HPE needs to be disabled(SCGCQ01996375 port of SCGCQ01985589) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02009848 port of SCGCQ01992461) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02011417 port of SCGCQ01761309) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02043788 port of SCGCQ02040783) 
 - Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02124488 port of SCGCQ02123789) 
 - Storcli: "completeflash" is listed in Windows help file.(SCGCQ02145743 port of SCGCQ02141931) 
 - Storcli: /c0 set ? lists bbu,mx,px and lnx commands.	(SCGCQ02145756 port of SCGCQ02136689) 
 - Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02145764 port of SCGCQ02136333) 
 - Help note 'page=[x]' needs update(SCGCQ02149062 port of SCGCQ02146823) 
 - Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02153948 port of SCGCQ02150924) 
 - Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02154721 port of SCGCQ02135526) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Aero (DBU PA2(SCGCQ02086670 port of SCGCQ02082460) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02079507 port of SCGCQ02078437) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all	(SCGCQ02047235 port of SCGCQ02040756) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Request to Disable DSW3(SCGCQ01903331 port of SCGCQ01896311) 
 - PERCCLI Support for EKMS(SCGCQ01904188 port of SCGCQ01902150) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01904340 port of SCGCQ01413253) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921529 port of SCGCQ01220901) 
 - Hide "set termlog" help contents from perccli(SCGCQ01935143 port of SCGCQ01923643) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01940869 port of SCGCQ01937410) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01945534 port of SCGCQ01940805) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01965393 port of SCGCQ01935697) 
 - Storcli shows wrong PD list sequence.(SCGCQ01971632 port of SCGCQ01967488) 
 - LD size not shown in GiB format in foreign import preview(SCGCQ01996370 port of SCGCQ01978978) 
 - Unable to switch to eHBA mode using a H745P Adapter(SCGCQ01998964 port of SCGCQ01990060) 
 - perccli show profile lists personality as JBOD instead of eHBA(SCGCQ01998966 port of SCGCQ01998328) 
 - Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101377 port of SCGCQ02101372) 
 - In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02116733 port of SCGCQ02115036) 
 - complete Lane WWID is not displayed(SCGCQ02145739 port of SCGCQ02145716) 
 - No "Rbld" legend during rebuild.	(SCGCQ02150634 port of SCGCQ02146819) 
 - Error message mismatch is seen for rttdump command on iMR Ventura controller.(SCGCQ02160907 port of SCGCQ02156483) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324)
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - Storcli shows wrong PD list sequence.(SCGCQ01977461 port of SCGCQ01967488) 
 - Migrate Failure case is not Branding compliant(SCGCQ02000716 port of SCGCQ01988402) 
 - StorCLI PH12: Retrieving topology details causes application crash in some scenario(SCGCQ02106192 port of SCGCQ02103217) 
 - Support FMP Images in UEFI Version of PERCCli(SCGCQ02116464 port of SCGCQ02078649) 
 - MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02116497 port of SCGCQ02114898) 
 - PH12 PA - StorCLI - 9310-8i IR FW download fails	(SCGCQ02121848 port of SCGCQ02121783) 
 - LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02139867 port of SCGCQ02085102) 
 - MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend	(SCGCQ02168256 port of SCGCQ02165944) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02079597 port of SCGCQ02035437) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Incorrect status displayed for resume copyback command.	(SCGCQ02075291 port of SCGCQ02062834) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01929892 port of SCGCQ01106988) 
 - Added new commands from StorCLI(SCGCQ01935296 port of SCGCQ01134166) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01964024 port of SCGCQ01923119) 
 - securesed autoconfig param should not be present for perccli help(SCGCQ01986879 port of SCGCQ01986831) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032582 port of SCGCQ02029410) 
 - Drives connected to active backplanes not showing the phy info in connector name	(SCGCQ02112425 port of SCGCQ02112424) 
 - Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02150630 port of SCGCQ02132024) 
 - Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02153950 port of SCGCQ02150921) 
 - Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02154755 port of SCGCQ02150651) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.	(SCGCQ02079601 port of SCGCQ01992461) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - Storcli: HPE serial number programming and display(SCGCQ02062635 port of SCGCQ01882984) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893381 port of SCGCQ01892288) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01930028 port of SCGCQ01141462) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01936895 port of SCGCQ01935697) 
 - Terminology change from " Data protection" to " Data integrity".(SCGCQ01940807 port of SCGCQ01827339) 
 - Libmods: Terminology change from " Data protection" to " Data integrity".(SCGCQ01943370 port of SCGCQ01827732) 
 - Incorrect colinfo output of Bad block count(SCGCQ01977457 port of SCGCQ01977443) 
 - StorCLI hangs when viewing controller in FreeBSD (MR7.8 is okay(SCGCQ01984543 port of SCGCQ01978824) 
 - Unified StorCLI : Help command of "Get flash" is not shown in generic help syntax(SCGCQ01985472 port of SCGCQ01985463) 
 - StorCLI show output shows Legends as BBU instead of EnergyPack.(SCGCQ01992007 port of SCGCQ01985587) 
 - Aero A0 UTP: StorCLI snapdump command needs to clarify new "On Demand" snapdump option(SCGCQ01995066 port of SCGCQ01993722) 
 - Shenandoah:StorCLI:Right click properties for released binary shown blank.(SCGCQ02000843 port of SCGCQ01988329) 
 - Smart Carrier Enclosure port info shown as "Multuipath"(SCGCQ02008273 port of SCGCQ01992087) 
 - MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json	(SCGCQ02116771 port of SCGCQ02112192) 
 - "Storcli /c# set jbod=on" shows success but does nothing	(SCGCQ02119067 port of SCGCQ02117219) 
 - Phyreset Fails on IT controllers	(SCGCQ02169305 port of SCGCQ02169242) 
 - Storcli stop erase needs an help file update	(SCGCQ02169308 port of SCGCQ02168895) 
 - Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02185911 port of SCGCQ02184862) 
 - Storcli connector display not matching with Aero board 9560-16i.	(SCGCQ02085681 port of SCGCQ02072448) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - PERCCLI Support for EKMS	(SCGCQ01904189 port of SCGCQ01903448) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911832 port of SCGCQ01886637) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915313 port of SCGCQ01222855) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915315 port of SCGCQ01227144) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ01998965 port of SCGCQ01998332) 
 - PH12 PA - StorCLI version not getting printed for show file command	(SCGCQ02116759 port of SCGCQ02105185) 
 - Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176697 port of SCGCQ02176681) 
 - With IT controller for set or reset with invalid phy is not showing error(SCGCQ02183510 port of SCGCQ02181823) 
	
EnhancementRequests:
 - Incorporating VMware constraints for PERCCLI VIB signing	(SCGCQ02190441) 
 - Migrating VMware 64 bit toolchain to 6.8.7-13394445(SCGCQ02190429) 
 - Create an event for DDF config clear failed event.(SCGCQ02173513) 
 -	(SCGCQ02162699) 
 - Snap Dump ClearAll Method logging event(SCGCQ02157359) 
 - API changes for a better presentation of Atlas to tools(SCGCQ02149380) 
 - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) 
 - Better error message for certain unmap operations(SCGCQ02111563) 
 - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change(SCGCQ02103973) 
 - MR Windows IOCTL Error codes to Application added to MR API(SCGCQ02103183) 
 - API changes for linkconfig interface	(SCGCQ02053671) 
 - API changes for NVMe speed and width changes	(SCGCQ02053667) 
 - Reword event log messages as it creates unnecessary panic.(SCGCQ02013675) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949495) 
 - Unified StorCLI : Adding component level download functionality to StorCLI(SCGCQ01940030) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01927541) 
 - snapdump support for host initiated snapdump	(SCGCQ01901158) 
 - Changes for disable least latency mode(SCGCQ01891451) 
 - Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01929656) 
 - MR_SAS_Unified_Libmods_7.10 Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01979597) 
 - Post firmware trace buffer at the time of driver load(SCGCQ01992779) 
 - Adding the spare details in the same volume creation(CONFIG_ADD DCMD(SCGCQ02008407) 
 - PSoC implementation in StorCLI by parsing PSoC image(SCGCQ02072160) 
 - Request to display the help for "show" and "set" for JBOD in PercCLI	(SCGCQ02160291) 
 - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) 
 - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) 
 - Enable iMR advanced debug dump(SCGCQ02030908) 
 - Unified StorCLI : ARM Windows support to StorCLI(SCGCQ01962294) 
 - Disabling RAID00 support	(SCGCQ01960420) 
 - HPE Shenandoah: Branding tool(SCGCQ01960295) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949503) 
 - Unified StorCLI : Allow SBR/SPD read and write using new CBB+SBR concatenated image(SCGCQ01927551) 
 - show complete Serial Number and Model Name for NVMe drive connected to IT controller(SCGCQ01927538) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01919655) 
 - Unified CLI - Command processor changes for handling invalid/tampered device id's for sea IT controllers(SCGCQ01891513) 
 - Add support to display PSOC version for Ventura IT controllers(SCGCQ02067300) 
 - set copyback command changes for cli(SCGCQ02148092) 
 - Unified StorCLI : ARM64 Windows support to StorCLI - LibMod changes(SCGCQ01963208) 
 - Shenandoah: Adding support bit check for delete snap dump(SCGCQ01944500) 
 - Enable iMR advanced debug dump(SCGCQ01873124) 
 - Unified StorCLI : PSoC read and write via Device read and write DCMD's in MR Operational case(SCGCQ01949521) 
 - Changes for disable least latency mode(SCGCQ01891442) 
 - Adding the spare details in the same volume creation (CONFIG_ADD DCMD(SCGCQ02008403) 
 - Unified StorCLI : Allow erase functionality on operational MR using CBB concatenated image(SCGCQ01927595) 
 - Unified CLI : Handling invalid/tampered controllers for sea controllers(SCGCQ01891484) 
 - Requesting StorCLIF to read MR FW from flash device and write it to a file. Similar to what IT FW support.(SCGCQ01631948) 
 - Add ability to field upgrade PSOC on HBA boards(SCGCQ01583214) 
 - DUal Image SUpport(SCGCQ01960287) 
 - Libmods: Porting HPE Shenandoah from Aero to 7.9	(SCGCQ01917263) 
 - Porting HPE Shenandoah from Aero to 7.9(SCGCQ01917172) 
 - Adding HPE specific help for storcli	(SCGCQ01935699) 


007.0816.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

defects:
  - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01824574 port of SCGCQ01824569) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01827604 port of SCGCQ01681538) 
 - Updating makefile and EFI's INF changes for ARM StorCLIO(SCGCQ01870684 port of SCGCQ01563125) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ02085925 port of SCGCQ01998332) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853370 port of SCGCQ01775616) 
 - (SCGCQ01775602 port of SCGCQ01814011)
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - Storcli shows incorrect output for delete events command	(SCGCQ02046875 port of SCGCQ02045816) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - Drive Size Display Miss Match In Storcli Show Output(SCGCQ02075280 port of SCGCQ02072353) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02097658 port of SCGCQ02096774) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01850374 port of SCGCQ01837932) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02047079 port of SCGCQ02024740) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02047235 port of SCGCQ02040756) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - show/set lane speed shows success when we are in SAS profile	(SCGCQ02079507 port of SCGCQ02078437) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - Aero (DBU PA2)(SCGCQ02086670 port of SCGCQ02082460) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01857450 port of SCGCQ01856544) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01825986 port of SCGCQ01824570) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01832791 port of SCGCQ01816927) 
 - Add interface in storecli that could get relearn complete status	(SCGCQ01850373 port of SCGCQ01848387) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/ eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02075291 port of SCGCQ02062834) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"	(SCGCQ02079597 port of SCGCQ02035437) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/ px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - Aero - LibMod changes for ER SCGCQ01813156 : Addition of Aero and Sea device id's and checkwords	(SCGCQ01853418 port of SCGCQ01813626) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02079601 port of SCGCQ01992461) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Add get VPD command support to StorCLI in OS environment	(SCGCQ01855067 port of SCGCQ01852603) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 - CSET: Checking in Libmod changes for defect SCGCQ02030652 - (SCGCQ02045948(SCGCQ02047884 port of ) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02085681 port of SCGCQ02072448)

EnhancementRequest:
- Updating ncurses library from 6.0 to 6.1(SCGCQ01836749) 
 - Command processor changes for Secure boot properties feature - SCGCQ01855473	(SCGCQ01855503) 
 - Adding secure boot properties to unified StorCLI	(SCGCQ01855473) 
 - Adding new MFI STAT - MFI_STAT_SECURE_BOOT_KEY_SLOTS_FULL 007.0711.0000.0000 for Lenovo(SCGCQ01865190) 

007.0713.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) 
 - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01556595) 
 - controller show all command is not listing the Battery information(SCGCQ01561689) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) 
 - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) 
 - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) 
 - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) 
 - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) 
 - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) 
 - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) 
 - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) 
 - Spell mistake in error message for hwdev command(SCGCQ01614972) 
 - Coverity defect fix for itctflash file(SCGCQ01616369) 
 - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) 
 - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) 
 - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) 
 - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) 
 - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) 
 - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) 
 - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) 
 - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) 
 - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) 
 - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) 
 - Help content for jbodx show unmap is not present(SCGCQ01790130) 
 - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - storclio command not working to update FW on SATA disk(SCGCQ01918814) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) 
 - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) 
 - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) 
 - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) 
 - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) 
 - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) 
 - Checking in VBAS compliation changes(SCGCQ01630324) 
 - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) 
 - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) 
 - Space need in the output for secure erase(SCGCQ01713604) 
 - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) 
 - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) 
 - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) 
 - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) 
 - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) 
 - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01735493) 
 - Storcli vib update fails across releases.(SCGCQ01761795) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) 
 - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) 
 - Removing the set/show of unmap on JBOD.(SCGCQ01817855) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) 
 - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) 
 - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) 
 - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01595640) 
 - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) 
 - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) 
 - Update help contents for jbod delete(SCGCQ01624605) 
 - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) 
 - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) 
 - Missing punctuation in Perccli delete config message(SCGCQ01698226) 
 - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) 
 - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) 
 - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) 
 - Drive Fw download Coverity fixes(SCGCQ01615074) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) 
 - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) 
 - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) 
 - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) 
 - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) 
 - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) 	
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) 
 - Updating the Diag results as per new API changes(SCGCQ01537255) 
 - Resource leaks,Uninitialized variables(SCGCQ01600311) 
 - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) 
 - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) 
 - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) 
 - Removal of ncurses references for linux makefile(SCGCQ01955544) 
  - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) 
 - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) 
 - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) 
 - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) 
 - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) 
 - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) 
 - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) 
 - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) 
 - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) 
 - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) 
 - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) 
 - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) 
 - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) 
 - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) 
 - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) 
 - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) 
 - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) 
 - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) 
 - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) 
 - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) 
 - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) 
 - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) 
 - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) 
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) 
 - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) 
 - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) 
 - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) 
 - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) 
 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) 
 - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) 
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) 
 - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) 
 - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) 
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) 
 - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) 
 - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) 
 - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) 
 - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) 
 - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) 
 - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) 
 - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) 
 - .(SCGCQ01571935 port of SCGCQ01325052) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) 
 - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) 
 - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) 
 - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) 
 - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) 
 - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) 
 - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) 
 - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) 
 - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) 
 - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) 
 - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) 
 - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) 
 - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) 
 - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) 
 - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) 
 - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) 
 - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) 
 - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) 
 - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) 
 - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 
EnhancementRequests
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) 
 - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) 
 - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) 
 - Need Storcli support drive FW upgrade(SCGCQ01583217) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) 
 - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) 
 - Add a bit for atomic descriptor capable(SCGCQ01965047) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01583223) 
 - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) 
 - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) 
 - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) 
 - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) 
 - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) 
 - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 


007.0525.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects (16)
-.(SCGCQ01753405)
- Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033)
- Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315)
- Enclosure show status command gives success but nothing is shown.(SCGCQ01731280)
- One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763)
- Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927)
- Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612)
- Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548)
- Space need in the output for secure erase.(SCGCQ01713604)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Missing punctuation in Perccli delete config message.(SCGCQ01698226)
- Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265)
- non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272)
- DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443)
- WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279)
- Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752)
- perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719)
- storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990)
- State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444)
- Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355)
- storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816)
- Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795)
- storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493)
- Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849)
- Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269)
- "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017)
- controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704)
- Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749)
- Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493)
- Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354)
- PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418)
- Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616)
- Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223)
- Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972)
- StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602)
- Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983)

EnhancementRequests (30)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730)
-.(SCGCQ01593479)
-.(SCGCQ01761309)
- displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528)
- Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603)


0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence
-------------------

Defects (75)
- Profile Mgmt API Changes.( SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- Enable WB support via API.(SCGCQ01405242)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979)
- Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940)
- storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171)
- Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396)
- Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401)
- Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745)
- Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131)
- Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420)
- Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852)
- Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910)
- Detailed help contents were not present for most of the IT download options..(SCGCQ01483760)
- Spelling errors in the "/cx restart" command..(SCGCQ01486415)
- Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052)
- CLI help does not reflect the new command to create an ePD.(SCGCQ01639583)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- Instance Validation is failing for mentioned commands..(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447)
- Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990)
- PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588)
- Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580)
- Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694)
- PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920)
- PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062)
- Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041)
- Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421)
- Checking in VBAS compliation changes.(SCGCQ01630324)
- PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798)
- Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240)
- Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214)
- MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582)
- Schema addition for "show file=" command.(SCGCQ01461209)
- PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593)
- MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562)
- PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762)
- Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845)
- Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344)
- Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670)
- OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785)
- Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797)
- Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- Incorrect help description for erase and download completeflash commands.(SCGCQ01470263)
- Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802)
- Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833)
- Check for supported pages for firing drive SCSI commands.(SCGCQ01474325)
- No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900)
- IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753)
- Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446)
- Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195)
- Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334)
- Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821)
- UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749)


EnhancementRequests (174)
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType..(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- JSON schema for Drive level commands.(SCGCQ01445435)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
-.(SCGCQ01389581)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- Removing the NMR storcli commands from storcli..(SCGCQ01445268)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
- Removing the NMR storcli commands from storcli..(SCGCQ01445418)
-.(SCGCQ01428114)
-.(SCGCQ01423509)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987)
- Add NVMe device related changes.(SCGCQ01034678)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986)
- Add boot drive selection support in Stor-CLI.(SCGCQ01445896)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424)
-.(SCGCQ01466805)
- StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954)
- StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799)
- Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308)
- Add support for IT Firmware images and IT Completeflash images to "show file=" command.(SCGCQ01436882)

CSETActivities (57)
- StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445)
- Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174)
- Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483)
- Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457)
- Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170)
- Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237)
- SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496)
- Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245)
- This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717)
- Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154)
- Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920)
- Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496)
- Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780)
- Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929)
- Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698)
- Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009)
- Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154)
- storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595)
- Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709)
- Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360)
- Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764)
- Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886)
- Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526)
- Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435)
- Updating readme file(SCGCQ01294583 port of SCGCQ01294570)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453)
- Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412)
- Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234)
- Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605)
- Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562)
- Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703)
- Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628)
- Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447)
- Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256)
- Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552)
- Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578)
- Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900)
- DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749)
- syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675)
- controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689)
- Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481)
- Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460)
- Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156)
- Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214)
- CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640)
- Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618)
- Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793)
- Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255)
- Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754)

0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------
fixes:
- Profile Mgmt API Changes.(SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846)
- Fixing Error Handling issues and Resource leak.(SCGCQ01319395)
- Fix for Libmod files having potential loop errors.(SCGCQ01320336)
- Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003)
- EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452)
- Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604)
- Updated the Help.(SCGCQ01375059)
- controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816)
- Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238)
- storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690)
- Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425)
- Fixing out of bounds in libmods.(SCGCQ01385430)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177)
- Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543)
- PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511)
- Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756)
- Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011)
- Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239)
- Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897)
- Need to handle FW return code change for profile management success case.(SCGCQ01307320)
- Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405)
- PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477)
- Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749)
- CLI reports failure when issuie DPM commands.(SCGCQ01333085)
- PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041)
- Fixing unchecked return values.(SCGCQ01385377)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610)
- Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922)
- LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583)
- Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764)
- Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948)
- Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222)
- This is a syntactical error where a comma was added.(SCGCQ01414744)
- Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208)
- Instance Validation is failing for mentioned commands.(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
- StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018)
- IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046)
- Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219)
- Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438)
- Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771)
- Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
- PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757)
- Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407)
- Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042)
- CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639)
- Removing the memory leaks in dequelog command.(SCGCQ01411544)
- Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758)
- Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934)
- Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Fixing Out of Bounds access and Resource leak.(SCGCQ01304875)
- Inconsistencies between the applications for manage link speed.(SCGCQ01389856)
- Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106)
- Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- StorCLI: Spindown help syntax is misleading.(SCGCQ01421610)
- Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
- StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900)
- Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891)
- Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748)
- Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890)
- Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943)
- Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289)
- StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557)
- Removing the NMR command for setting SCAPVPD.(SCGCQ01389451)
- Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749)

EnhancementRequests:
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType.(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
-.(SCGCQ01421997)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793)
- RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354)
- Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469)
- Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465)
- List pending profile details of the controller.(SCGCQ01346308)
-.(SCGCQ01291037)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- always print StorCLI version information at beginning/top of output.(SCGCQ01396733)
- StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177)
- New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
-.(SCGCQ01428114)
- Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646)
- Add NVMe device related changes.(SCGCQ01034678)
- Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301)
- Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079)
- Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)

CSETActivities:
- StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018)
- MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830)
- Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790)
- MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315)
- MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798)
- Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785)
- SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496)
- Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610)
- Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900)
- CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 )
- Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789)
- Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152)
- Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673)
- Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381)
- Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320)
- MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757)
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529)
- MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520)
- Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274)
- MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453)
- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843)
- Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891)
- CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 )
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177)
- Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604)
- Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843)
- Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152)
- C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830)
- Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495)
- Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145)
- Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484)
- [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914)
- Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728)
- MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756)
- MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493)

0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
 - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536)
 - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913)
 - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948)
 - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629)
 - Code clean up in libmods and sysefi files are added(SCGCQ00359998)
 - Storcli is returning error with show(SCGCQ00360040)
 - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814)
 - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216)
 - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717)
 - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455)
 - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522)
 - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097)
 - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248)
 - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622)
 - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735)
 - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000)
 - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155)
 - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735)
 - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364)
 - portings of AdpRestart command(SCGCQ00378135)
 - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828)
 - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104)
 - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303)
 - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789)
 - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832)
 - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350)
 - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610)
 - SWR_1.34(SCGCQ00442652)
 - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502)
 - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583)
 - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843)
 - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560)
 - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201)
 - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579)
 - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935)
 - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835)
 - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123)
 - Storcli : unable to set patrol read delay(SCGCQ00645195)
 - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324)
 - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742)
 - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131)
 - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171)
 - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192)
 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505)
 - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647)
 - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770)
 - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178)
 - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183)
 - Adapters are not listed in sorted order.(SCGCQ00759969)
 - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398)
 - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752)
 - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663)
 - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712)
 - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243)
 - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789)
 - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882)
 - "cpybck" help is not coming in Legends(SCGCQ00784808)
 - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400)
 - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232)
 - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374)
 - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394)
 - .(SCGCQ00800878)
 - Deallocation of the same memory more than once(SCGCQ00802031)
 - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588)
 - Out-of-bounds access and array delete misuse(SCGCQ00804680)
 - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547)
 - Not able add new VD in Drive Group(SCGCQ00813314)
 - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939)
 - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049)
 - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299)
 - storcli /call show all fails with "command invalid"(SCGCQ00830269)
 - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342)
 - Profile Mgmt API Changes(SCGCQ00883008)
 - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417)
 - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738)
 - The code had events with repetitive ID and some structures clashing(SCGCQ00948535)
 - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835)
 - 800C error when execting Get MFC default function(SCGCQ01037840)
 - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936)
 - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284)
 - No ISE Capable field(SCGCQ01148693)
 - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175)
 - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698)
 - Fixing Resource leaks(SCGCQ01205356)
 - resource validation before de referencing(SCGCQ01206104)
 - Fixing resource leaks in libmods(SCGCQ01208044)
 - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393)
 - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414)
 - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473)
 - Fix for resource leak in system config show(SCGCQ01210133)
 - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415)
 - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383)
 - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923)
 - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217)
 - NVMe PD SMART DATA shows all 0's(SCGCQ01236052)
 - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715)
 - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381)
 - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687)
 - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688)
 - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928)
 - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421)
 - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632)
 - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445)
 - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336)
 - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979)
 - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883)
 - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094)
 - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474)
 - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620)
 - Some sparc structures missing for storcli.(SCGCQ00504585)
 - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761)
 - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658)
 - storecli reports wrong size on 3000MB VD(SCGCQ00644545)
 - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962)
 - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672)
 - Add support bits for uneven-span and SSHA support(SCGCQ00755063)
 - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101)
 - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924)
 - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290)
 - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959)
 - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385)
 - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937)
 - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714)
 - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759)
 - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347)
 - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363)
 - Storcli errors are printing in a different line.(SCGCQ00771626)
 - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302)
 - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332)
 - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577)
 - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800)
 - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357)
 - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202)
 - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761)
 - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393)
 - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335)
 - Resource leak(SCGCQ00804745)
 - .(SCGCQ00811452)
 - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672)
 - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205)
 - Fix for profile management support check bit(SCGCQ01208103)
 - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411)
 - Unified Storcli: Fixing resource leak issues(SCGCQ01209413)
 - SAS3.5 Ventura(SCGCQ01219196)
 - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153)
 - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169)
 - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376)
 - Need to handle FW return code change for profile management success case(SCGCQ01307320)
 - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263)
 - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644)
 - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663)
 - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978)
 - storcli /c0 show is not listinf SWR controller(SCGCQ00454971)
 - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116)
 - Raptor Galaxy : Storcli(SCGCQ00475562)
 - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981)
 - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771)
 - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763)
 - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073)
 - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800)
 - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416)
 - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775)
 - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174)
 - storelib header file changes porting(SCGCQ00609942)
 - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023)
 - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969)
 - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070)
 - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000)
 - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187)
 - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806)
 - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918)
 - Missing the Display of the property temperatureCtrl.(SCGCQ00792264)
 - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760)
 - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336)
 - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206)
 - Memory not freed which can cause leak(SCGCQ00804554)
 - Varailble need to be freed before returning in all failure case(SCGCQ00804650)
 - IDA show incorrect RAID controller type information(SCGCQ00806966)
 - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197)
 - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372)
 - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111)
 - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464)
 - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723)
 - Removing Unused and logically dead code in storcli(SCGCQ01204045)
 - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492)
 - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685)
 - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083)
 - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
 - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332)
 - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100)
 - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043)
 - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956)
 - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370)
 - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287)
 - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672)
 - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181)
 - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862)
 - CPLD(SCGCQ00787705)
 - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233)
 - rlListPtr is not handled properly in failure case(SCGCQ00796227)
 - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392)
 - LDViewMirror is giving segmentation fault(SCGCQ00830435)
 - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758)
 - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321)
 - Checking in compilation error for Libmods(SCGCQ00919973)
 - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356)
 - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055)
 - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407)
 - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101)
 - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553)
 - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709)
 - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745)
 - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950)
 - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070)
 - debug prints are present when issuing /co/eall show(SCGCQ00475815)
 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543)
 - Verify StorCLI warns on destructive operations(SCGCQ00712982)
 - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584)
 - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691)
 - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358)
 - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200)
 - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211)
 - Incorrect sizeof expression in dcmdprm(SCGCQ00793354)
 - Non-array delete for objects in rmdatamf(SCGCQ00793361)
 - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420)
 - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663)
 - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
 - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736)
 - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583)
 - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096)
 - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306)
 - PD related information missing for NVMe drives(SCGCQ01126564)
 - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365)
 - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854)
 - StorCLI(SCGCQ01274554)
 - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911)
 - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070)
 - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665)
 - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107)
 - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008)
 - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605)
 - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
 - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402)
 - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205)
 - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334)
 - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342)
 - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311)
 - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117)
 - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368)
 - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844)
 - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353)
 - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082)
 - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437)
 - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721)
 - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236)
 - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289)
 - Help for Compare linkspeed is not complete(SCGCQ01275454)
 - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037)
 - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491)
 - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067)
 - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426)
 - Libmod changes to support profile management(SCGCQ01048228)
 - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627)
 - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876)
 - Ventura PH3(SCGCQ01253012)
 - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455)
 - coverity removing out of bounds reads from code(SCGCQ01280460)
 - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999)
 - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085)
 - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234)
 - Resource leak in VdDataMf scanPartitions(SCGCQ00793363)
 - Storcli can't create AHCI LDs(SCGCQ00897637)
 - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676)
 - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024)
 - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214)
 - Detailed help missing for IT erase commands(SCGCQ01275474)
 - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671)
 - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453)
 
Enhancement
 
 - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167)
 - New fault code for routine synchronous reset(SCGCQ01264142)
 - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358)
 - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050)
 - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414)
 - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228)
 - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796)
 - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215)
 - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613)
 - API changes for CR55(SCGCQ01222700)
 - API change for Simplified RAID10 Creation(SCGCQ01222698)
 - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406)
 - API changes for PR SCGCQ01139678(SCGCQ01215334)
 - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 - API changes for PR SCGCQ01127742(SCGCQ01203751)
 - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 - MR 6.12(SCGCQ01146597)
 - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251)
 - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344)
 - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627)
 - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969)
 - MPI 2.5: Add new connector types(SCGCQ01085073)
 - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360)
 - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162)
 - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885)
 - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208)
 - MPI 2.5: update copyright info(SCGCQ00728066)
 - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829)
 - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820)
 - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175)
 - Add type BIOS for HashImageType.(SCGCQ00566306)
 - Identify physical location of a target device(SCGCQ00523879)
 - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817)
 - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293)
 - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819)
 - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437)
 - Allow Protection Information bit for IR Volume Create(SCGCQ00385306)
 - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551)
 - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271)
 - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270)
 - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266)
 - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260)
 - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506)
 - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383)
 - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439)
 - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131)
 - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055)
 - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759)
 - MPI 2.6: SOP Encapsulated request(SCGCQ00264755)
 - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183)
 - Libmods changes for EFI support for Unified storcli(SCGCQ00923719)
 - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101)
 - OEL Support for SPARC(SCGCQ00787923)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007)
 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477)
 - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399)
 - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735)
 - MPI 2.6: add IO Unit Control Request(SCGCQ00345258)
 - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272)
 - MPI 2.6: Enclosure Management(SCGCQ00345273)
 - Device Info field for PCIe devices(SCGCQ00353339)
 - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843)
 - MPI 2.6: new family values for ProductID fields(SCGCQ00360952)
 - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600)
 - Modified address space bits(SCGCQ00397136)
 - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563)
 - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568)
 - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572)
 - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577)
 - MPI 2.6: Add NVMe SGL support(SCGCQ00398256)
 - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541)
 - MPI 2.6: System Interface Register Set update(SCGCQ00464402)
 - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292)
 - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998)
 - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281)
 - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070)
 - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869)
 - MPI 2.6: Add new FLASH region types(SCGCQ00619371)
 - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271)
 - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957)
 - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527)
 - MPI 2.6: Extend Task Management(SCGCQ00686666)
 - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177)
 - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600)
 - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389)
 - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088)
 - MPI 2.6: add PCI Device ID's(SCGCQ00828497)
 - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588)
 - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827)
 - MPI 2.6: Update Flash Signature.(SCGCQ00852831)
 - profile management API(SCGCQ00867953)
 - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169)
 - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328)
 - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262)
 - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740)
 - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256)
 - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336)
 - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213)
 - MPI 2.6: Remove all SOP references(SCGCQ00925839)
 - Change library name to SLIT(SCGCQ00933175)
 - Ventura: de-feature AHCI(SCGCQ00941620)
 - MPI 2.6: Remove all AHCI references(SCGCQ00948258)
 - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955)
 - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638)
 - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619)
 - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104)
 - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930)
 - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826)
 - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027)
 - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687)
 - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473)
 - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741)
 - mega api changes for ibuttonless PR(SCGCQ01059740)
 - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009)
 - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374)
 - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821)
 - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340)
 - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549)
 - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837)
 - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839)
 - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127)
 - MPI 2.6: Add new clean tool options(SCGCQ01141732)
 - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583)
 - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725)
 - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092)
 - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367)
 - MPI 2.5: Signed images for FWDownload(SCGCQ00469990)
 - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512)
 - Display the Storelib version in the show command.(SCGCQ01286063)
 - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457)
 - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496)
 - Add support to allow Device names greater than 107(SCGCQ01039328)
 - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636)
 - Enable SED on JBOD(SCGCQ00755527)
 - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230)
 - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051)
 - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474)
 - Implemented the diag results to print on console(SCGCQ00525321)
 - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742)
 - MWCLI. Add HA support into storcli(SCGCQ00352120)
 - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668)
 - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607)
 - Add NVMe device related changes(SCGCQ01034678)
 - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665)
 - Complete 240VD support for utilities(SCGCQ00693042)
 - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287)
 - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311)
 - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793)
 - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715)
 - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821)
 - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146)
 - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204)
 - UDK Support for EFI(SCGCQ00795150)
 - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171)
 - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872)
 - Provide a way to enable or disable 512E using Applications(SCGCQ00351234)
 - Refer attached design doc(SCGCQ00349599)
 - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)
 - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050)
 - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217)
 - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344)
 - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473)
 - RRB 71(SCGCQ00750164)
 - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081)
 - SED/FDE changes for storcli Synchro(SCGCQ00632240)
 - ASD- StorCLI(SCGCQ00467863)
 - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209)
 - PERC 10 WIndows Support(SCGCQ01213160)
 - PERC 10 WIndows Support(SCGCQ01213157)
 - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080)
 - Megacli/storcli support for lmrc driver(SCGCQ00433703)
 - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093)
 - Uneven span support is added in StorCLI.(SCGCQ00349548)
 - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391)
 - Add EFI support for the manufacturing command to program.(SCGCQ01191095)
 - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216)
 - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476)
 - Monitoring Drive performance and predictive failure(SCGCQ00817977)
 - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118)
 - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237)
 - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987)
 - Functionality to extract field value from new API changes(SCGCQ00794841)
 - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815)

0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.

1.20.20 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227)
- Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335)
- Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866)
- Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811)
- Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074)
- Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438)
- Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663)
- Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140)
- Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401)
- Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258)
- Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358)
- Fixed an issue where storcli does not display description on command success - (SCGCQ01023973)
- Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081)
- Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945)
- Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534)
- Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430)
- Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535)
- Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218)
- Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102)
- Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484)
- Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534)
- Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745)
- Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757)
- Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895)
- Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068)
- Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105)
- Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314)
- Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646)
- Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899)
- Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101)
- Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120)
- Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669)
- Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997)
- Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082)
- Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011)
- Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071)
- Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117)
- Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416)
- Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387)
- Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154)
- Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907)
- Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447)
- Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139)
- Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493)
- Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500)
- Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028)
- Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669)
- Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536)
- Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554)
- Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode  - (SCGCQ01043063)
- Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322)
- Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608)
- Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994)
- Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298)
- Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300)
- Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088)
- Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805)
- Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035)
- Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084)
- Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706)
- Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613)
- Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775)
- Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973)
- Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830)
- Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940)
- Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786)
- Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464)
- Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466)
- Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876)
- Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415)
- Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985)
- Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968)
- Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027)
- Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756)
- Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306)
- Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841)
- Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876)
- Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525)
- Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798)
- Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620)
- Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204)
- Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274)
- Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667)
- Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604)
- Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055)
- Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533)
- Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614)
- Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474)
- Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758)
- Fixed an issue where some commands may not report success on success - (SCGCQ01050695)
- Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241)
- Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116)
- Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773)
- Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500)
- Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378)
- Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493)
- Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205)
- Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864)
- Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540)
- Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766)
- Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178)
- Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305)
- Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482)
- Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514)
- Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493)
- Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642)
- Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528)
- Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477)
- Fixed an issue where installaton of storclio may fail - (SCGCQ00952422)
- Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981)
- Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790)
- Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315)
- Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178)
- Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865)
- Fixed an issue where EPD details may not show in "show all" command  - (SCGCQ00921937)
- Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624)
- Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489)
- Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330)
- Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837)
- Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484)
- Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697)
- Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461)
- Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597)
- Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760)
- Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891)
- Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993)
- Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617)
- Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault"  - (SCGCQ01020010, Port of SCGCQ01019547)
- Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212)
- Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145)
- Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101)
- Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181)
- Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177)
- Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789)
- Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable  - (SCGCQ01143941, Port of SCGCQ01026187)
- Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307)
- Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download  - (SCGCQ01110108, Port of SCGCQ00934755)
- Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211)
- Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584)

Enhancements:
- Added the personality change command was not present - (SCGCQ00850610)
- Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220)
- Added multipath support in EPD configuration options - (SCGCQ01015758)
- Added additional CPU support on EFI platform - (SCGCQ01026250)
- Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304)
- Added personality change features - (SCGCQ01111930)
- Added VF-queue depth mode settings - (SCGCQ00907072)
- Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320)
- Added Secure Erase support to JBOD and System drives - (SCGCQ00929757)
- Added a JBOD entity for various operations - (SCGCQ01047229)
- Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064)
- Added more specific error messages in some circumstances - (SCGCQ00920034)
- Added new compilation environment and makefiles - (SCGCQ00920058)
- Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739)
- Added support for drive microcode update Modes E and F - (SCGCQ01047223)
- Added code to display JBOD personality - (SCGCQ01146775)
- Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338)
- Added new erase type called Crypto - (SCGCQ01050618)
- Added new command to set the multiInit EPD parameter - (SCGCQ01080273)
- Added support for drive microcode update through parallel loading - (SCGCQ01024964)
- Added support for EPD creation - (SCGCQ00887664)
- Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414)


1.18.11 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705)
- Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785)
- Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612)
- Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196)
- Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339)
- Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620)

Enhancements:
- Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662)
- Added the support to set and clear the transport on a DG (SCGCQ00920046)
- Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318)
- Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795)
- Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030)
- Provide a more descriptive port enumeration (SCGCQ00854620)
- Add support to enable/Disable of Large IO Support (SCGCQ00894644) 

1.16.14 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617)
- Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176)
- Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715)
- Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755)

1.16.10 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617)
- Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470)
- Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914)
- Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143)
- Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429)
- Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770)


1.14.12 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Incorporated StorCLI MegaRAID 6.6 stream

Enhancements:
- Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171)
- Added consistent sorting of controllers using bus, device, function (SCGCQ00696872)
- Added ability to enable or disable 512e support (SCGCQ00351234)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527)
- Added ability for VMWare version to be run from any directory (SCGCQ00642230)
- Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477)
- Added ability to create a RAID00 (SCGCQ00350668)
- Added ability to display the Patrol Read Start Time (SCGCQ00564474)
- Added learn cycle progress information in show learn command (SCGCQ00644984)
- Added support for uneven spans (SCGCQ00349548)
- Added support for lmrc driver (SCGCQ00433703)
- Added 240 Virtual Drive support (SCGCQ00693042)
- Improved Punctured Block logging (SCGCQ00342399) 

1.12.15 - Moderate Impact/Low Probability of Occurrence
-------
Fix(es):
 - Prevent storCLI from allowing users to enable JBOD mode on
   controllers that do not support JBOD mode.
 - Updated CACHEBYPASS command to line up with user expectation.  When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass.

1.07.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M1215 SAS/SATA Controller
Fix(es):
 - Fixed an issue where segmentation faults may occur in Linux.
 - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS.
 - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying.

1.04.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M5210e and ServeRAID M5210
Fix(es):
 - Fixed an issue where a command failure results in subsequent commands and actions failing.
 - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR.
 - Added help file for for storcli /cx/dx set security
 - Fixed an issue where the "show ctrlcount help" command is not displaying properly.
 - Fixed an issue where a failure is displayed in the output for querying dimmer switch information.
 - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM.
 - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives.
 - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed.
 - Synced the pause pr command with show pr command to show correct PR Current State.
 - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property.

1.03.11 - Initial release
-------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2019 Lenovo. All rights reserved