Firmware Firmware Name Version
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.710.06.00_sles12sp4-1.x86_64.rpm 07.710.06.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.708.05.00_sles12sp4-1.x86_64.rpm 07.708.05.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.707.04.00-1.sles12sp4.x86_64.rpm 07.707.04.00_k4.12.14_94.41
Utilities Utility Name Version
MegaRAID Storage Manager Application for Linux (For Linux) 17.05.02.01
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
MegaRAID Storage Manager Application 17.05.01.03
StorCLI command line tool for anyos storcli-007.0713.0000.0000
MegaRAID Storage Manager Application 17.05.01.03

Release: 19C
Change History Documents
Firmware Firmware Name Version
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.710.06.00_sles12sp4-1.x86_64.rpm 07.710.06.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.708.05.00_sles12sp4-1.x86_64.rpm 07.708.05.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.707.04.00-1.sles12sp4.x86_64.rpm 07.707.04.00_k4.12.14_94.41
Utilities Utility Name Version
MegaRAID Storage Manager Application for Linux (For Linux) 17.05.02.01
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
MegaRAID Storage Manager Application 17.05.01.03
StorCLI command line tool for anyos storcli-007.0713.0000.0000
MegaRAID Storage Manager Application 17.05.01.03

Release: 19C
Change History Documents
Firmware Firmware Name Version
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update 6gb-23.34.0-0023-1
Drivers Driver Name Discreate Package Download Version
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.710.06.00_sles12sp4-1.x86_64.rpm 07.710.06.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.708.05.00_sles12sp4-1.x86_64.rpm 07.708.05.00_k4.12.14_94.41
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas- kmp-default-07.707.04.00-1.sles12sp4.x86_64.rpm 07.707.04.00_k4.12.14_94.41
Utilities Utility Name Version
MegaRAID Storage Manager Application for Linux (For Linux) 17.05.02.01
StorCLI command line tool for anyos (For Linux) storcli-007.1022.0000.0000
StorCLI command line tool for anyos storcli-007.0816.0000.0000
MegaRAID Storage Manager Application 17.05.01.03
StorCLI command line tool for anyos storcli-007.0713.0000.0000
MegaRAID Storage Manager Application 17.05.01.03


Release 19C Change History Documents

ServeRAID M5100 Series SAS/SATA Controllers for Lenovo System x BIOS and Firmware Update



ServeRAID 6GB SAS/SATA Controller Firmware Update

Adapters Supported:  ServeRAID M5115 SAS/SATA Controller (90Y4390)
		     Lenovo Storage Expansion Node (65Y8588)
		     ServeRAID M5110 SAS/SATA Controller for Lenovo System x (81Y4481)
		     ServeRAID M5110e SAS/SATA Controller for Lenovo System x 
		     ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478)

NOTE TO SERVICE - Reference RETAIN #N/A

Version 23.34.0-0023-1 - High Impact/High Probability of Occurrence
--------------------
FW PACKAGE: 23.34.0-0023
MR FW:  3.460.145-8209
iMR FW:  3.460.144-8208
BIOS:  5.50.03.0
UEFI:  0x06110200
HII:  03.17.14.04


Version 23.34.0-0023 - High Impact/High Probability of Occurrence
--------------------
FW PACKAGE: 23.34.0-0023
MR FW:  3.460.145-8209
iMR FW:  3.460.144-8208
BIOS:  5.50.03.0
UEFI:  0x06110200
HII:  03.17.14.04

Fixes:
- Fixed an issue where malformed incoming host commands could cause card reset in DataCenter. (SCGCQ01240574)
- Fixed an issue where iMR Montask while installing on degraded R5. (SCGCQ01165519)
- Fixed an issue where MRS section in the DDF is not updated when a drive is moved from rebuilding to online state. (SCGCQ01255906)
- Fixed an issue where IN FAILED ARRAY bit is not being set when a VD is cleared. (SCGCQ01287457)
- Fixed an issue where cache windows of physical drives with invalid signatures were not being accounted properly which was lead to an infinite loop and ultimately kill adapter. (SCGCQ01260339 Port of Defect SCGCQ01058771)
- Fixed an issue where Users can't change default access policy of SVD when it blocked by SSC removal. (SCGCQ01260344 Port of Defect SCGCQ00814937)


Version 23.34.0-0019 - High Impact/High Probability of Occurrence
--------------------
FW PACKAGE: 23.34.0-0019
MR FW:  3.460.115-6465
iMR FW:  3.460.114-6464
BIOS:  5.50.03.0
UEFI:  0x06110200
HII:  03.17.14.04

Fixes:
 - Fixed an issue where copyback was being set to on after any reboot or OCR. (SCGCQ01157490) 
 - Fixed an issue where copyback was not automatically initiated when manually setting drives to Unconfigured_Good (SCGCQ01181295)
 - Fixed an issue where foreign config import fails with DDF corruption (SCGCQ01172248)
 - Fixed an issue where firmware was not resetting learn cycle failed and learn cycle timeout fields when a new learn cycle starts and completes. (SCGCQ01174449)
 - Fixed an issue where system stall after sense key 04/c4/01 in HSP disk and controller reset repeatedly (SCGCQ01174450 Defect - SCGCQ01142402) 
 - Fixed an issue where data mis-compare could occur during recovery of CacheCade pinned windows across OCR/Reboot or CacheCade pinned windows could be discarded while CacheCade degrade flush in progress (SCGCQ01163950 Defect - SCGCQ01118285)
 - Fixed an issue where virtual drive erase wouldn�t complete if VD ID number is changed while the task is ongoing. (SCGCQ01182611)


Version 23.34.0-0018 -  High Impact/High Probability of Occurrence
--------------------
FW PACKAGE: 23.34.0-0018
MR FW:  3.460.105-6456
iMR FW:  3.460.104-6455
BIOS:  5.50.03.0
UEFI:  0x06110200
HII:  03.17.14.04

Fixes:
 - Disabled further usage of PI due to a potential data issue (SCGCQ01128078, SCGCQ01105478)
 - Fixed an issue where MegaRAID firmware crashes or hangs on systems with ASPM enabled on the host and disabled on the controller. (SCGCQ01123931)
- Fixed an issue where PI disabled before WJ flush (SCGCQ01135207)
- Fixed an issue where virtual drive secure erase resets after a reboot and hangs at 0%. (SCGCQ01137940)
- Fixed an issue where after reboot imported 4K drive R0 was not visible. (SCGCQ01156533)
- Fixed an issue where patrol read on PD with medium errors could not be stopped by the stop command. (SCGCQ01137941)

Version 23.34.0-0016 -  High Impact/High Probability of Occurrence
--------------------
FW Package: 23.34.0-0016

HII:  
03.17.14.04
UEFI Driver: 0x06110200
BIOS: 5.50.03.0
MR FW: 3.460.85-6425
iMR FW: 

 3.460.84-6424

Fixes:
 - Fixed an issue where enabling directpdmapping causes attached disk drives to be no longer be detected by storcli.  (SCGCQ01063721)
 - Fixed an issue where storcli commands and MSM are very slow when migratation activties are occurring.  (SCGCQ01086623)
 - Fixed an issue where Lenovo Info from storcli commands for bbu mismatches with the firmware log.  (SCGCQ01041511)

Version 23.34.0-0009 -  High Impact/High Probability of Occurrence
--------------------
FW Package: 23.24.0-0009

HII: 03.17.14.02 

UEFI Driver: 0x06110200

BIOS: 5.50.03.0

MR FW: 3.460.35-6104

iMR FW: 3.460.34-6103

 

Fixes:

 - Fixed the potential of a data miscompare that was observed only at a vendor test facility under very heavy IO and abnormal practices (SCGCQ00995594, Port of SCGCQ00976904)

 - Fixed an issue where error "Controller encountered fatal error and was reset" may occur under heavy IO and background operations (SCGCQ00894643)

 - Fixed an issue where VMWare may crash when a Guest Operating System is powered off (SCGCQ00872121, Port of SCGCQ00854914)

 - Fixed an issue where write-verify performance was lower than expected (SCGCQ00858151, SCGCQ00874193)

 - Fixed an issue where "I2C 4 PID 10 SCL STUCK Low! while I2C Rx receiving data intStatus 00008000" may appear in firmware log (SCGCQ01007592)

 - Fixed an issue where the Measured Voltage instead of Charging Voltage was displayed in event log (SCGCQ00876489)

 - Fixed an issue where Supercap "Battery Not Present" error may occur after shutdown or reboot during a learn cycle (SCGCQ00917115)

 - Fixed an issue where Write-through and Write-back cache policies can be changed via Windows Logical Disk Properties. (SCGCQ00856979)

 - Fixed an issue where enclosures may go missing when connected in daisy-chain after multiple expander reset cycles (SCGCQ00840725, Port of SCGCQ00818569)

 - Fixed an issue where MegaRAID Storage Mananger may display an error message if 'Schedule Consistency Check' is selected. (SCGCQ00852649, Port of SCGCQ00832908)

 - Fixed an issue where Patrol Read Properties window does not pop up on MegaRAID Storage Manager (SCGCQ00862478, Port of SCGCQ00797676)

 - Fixed an issue where MegaRAID Storage Manager shows messages with Error code 240 and no description (SCGCQ00970948, Port of SCGCQ00904466)

 - Fixed an issue where Amber LED may turn on erroneously when an enclosure's slot numbers start with 0 but bay numbers start with 1 (SCGCQ01019622, Port of SCGCQ00903181)

 - Fixed an issue where the Generic RAID1 profile option in HII is not greyed-out after creating 64 Virtual Drives (SCGCQ00826822, Port of SCGCQ00816137)

 - Fixed an issue where firmware may hang until system is reset (SCGCQ00928869, Port of SCGCQ00923286)

 - Fixed an issue where a Virtual Drive may disappear on reboot if it was created with drives from a previously-erased Virtual Drive (SCGCQ00937912, Port of SCGCQ00900237)

 - Fixed an issue where Functional Level Reset was not supported (SCGCQ00854343, Port of SCGCQ00840253)

 - Fixed an issue where an "L2 unrecoverable cache error" may occur when modifying Patrol read properties (SCGCQ00854668, Port of SCGCQ00847162)

 - Fixed an issue where a Hot Spare disk may become Unconfigured Good on reboot (SCGCQ00862477, Port of SCGCQ00803341)

 - Fixed an issue where SafeID may change on repeated queries using StorCLI (SCGCQ00949550, Port of SCGCQ00941577)

 - Fixed an issue where error "MonTask: line 1272 in file ../../raid/1078dma.c" may occur while running IO in Virtual Machines (SCGCQ01016071, Port of SCGCQ00822403)

 - Fixed an issue where incorrect connector information "connector: null x0" shows in MegaRAID Storage Manager (SCGCQ01016040, Port of SCGCQ00996578)

 - Fixed an issue where a concurrent Consistency Check cannot be started after resetting adapter to factory defaults (SCGCQ00839437, Port of SCGCQ00838830)

 - Fixed an issue where JBOD mode may be disabled if a Virtual Drives is offline (SCGCQ00871662, Port of SCGCQ00827731)

 

Enhancements:

 - Added protection for clearing Foreign Configuration if preserved cache exists (SCGCQ00880783, Port of SCGCQ00842327)

 - Enhanced cache restore operation for when restore data size is different than cache size (SCGCQ00860303, Port of SCGCQ00855038)

Version 23.33.0-0044 -  High Impact/High Probability of Occurrence
--------------------
Fixes:
 - Fixed an issue where controller may reset under heavy IO and background operations - (SCGCQ00894643) (RETAIN Tip H001154)
 - Fixed an issue where SuperCap "Battery Not Present" after shutdown and reboot during a learn cycle - (SCGCQ00917115)
 - Fixed an issue where a VD created with drives from a previously erased VD may disappear on next reboot - (SCGCQ00937912, Port of SCGCQ00900237)
 - Fixed an issue where firmware may incorrectly select backplane slots when updating drive status - (SCGCQ00980105)
 - Fixed an issue where MSM shows messages with Error Code 240 and no description - (SCGCQ00970948, Port of SCGCQ00904466)
 - Fixed an issue where SafeID may change with repeated queries using StorCLI - (SCGCQ00949550, Port of SCGCQ00941577)
 - Fixed an issue where a Foreign Configuration import may fail after reconstruction when using 4k sector drives - (SCGCQ00830109)
 - Fixed an issue where setting the Learn Cycle property of iBBU09 gives an I2C error - (SCGCQ00831315)
 - Fixed an issue where "Prepare for Removal" does not work on a PD when a drive erase is in progress - (SCGCQ00811219, Port of SCGCQ00703189)
 - Fixed an issue where EFI Driver Health fails when more than 64VDs are configured - (SCGCQ00831006, Port of SCGCQ00830918)
 - Fixed an issue where a controller may report Cache Memory size as 0 when no logical drives are present - (SCGCQ00837600, Port of SCGCQ00837162)
 - Fixed an issue where concurrent Consistency Checks cannot be started after issuing "setfactorydefaults" command - (SCGCQ00839437, Port of SCGCQ00838830)
 - Fixed an issue where Cache Memory size is not reporting 0 when there is no Cache Memory - (SCGCQ00838893, Port of SCGCQ00838193)
 - Fixed an issue where deleting a CacheCade VD can result in a firmware hang situation - (SCGCQ00838975, Port of SCGCQ00838953)
 - Fixed an issue where an incorrect error (MFI_STAT_PD_TYPE_WRONG (0x26) instead of MFI_STAT_LD_BLOCK_SIZE_MISMATCH (0x65)) is returned by the firmware when PDs with different block sizes are mixed - (SCGCQ00840251, Port of SCGCQ00836103)
 - Fixed an issue where BBU status reports Optimal but firmwre logs indicate the BBU has failed - (SCGCQ00838052, Port of SCGCQ00837834)
 - Fixed an issue where write-verify performance was lower than expected - (SCGCQ00858151)
 - Fixed an issue where Write-Through and Write-Back cache policies can be changed via Windows Logical Disk Properties - (SCGCQ00856979)
 - Fixed an issue where firmware reports no SMART error when a PFA (Predictive Failure) drive is attached - (SCGCQ00839455)
 - Fixed an issue where a status of 0xFF is erroneously returned from StoreLib - (SCGCQ00832673, Port of SCGCQ00827685)
 - Fixed an issue where an MSM displays an error message if "Schedule Consistency Check" is selected - (SCGCQ00852649, Port of SCGCQ00832908)
 - Fixed an issue where handling of Functional Level Reset (FLR) is not present - (SCGCQ00854343, Port of SCGCQ00840253)

Enhancements:
 - Changed the number of Sense Retry counts for a specific video application - (SCGCQ00841000)
 - Added ability to determine the revision ID for SuperCaps with no VPD programmed - (SCGCQ00828990)
 - Added support for SES RQST_OK deassertion - (SCGCQ00834321, Port of SCGCQ00817840)
 - Improved CPLD update capabilities - (SCGCQ00840631, Port of SCGCQ00758178)
 - Enhanced ability to flush cache with write-verify on RAID0 volumes with SATA drives - (SCGCQ00846777, Port of SCGCQ00842665)

Version 23.33.0-0043 -  High Impact/High Probability of Occurrence
--------------------
Fixes:
 - Fixed an issue where hard drive slot amber LED not functioning correctly.
 - Fixed an issue in iMR mode where "Controller encountered fatal error and was reset" errors can occur under heavy IOs and background operations (SCGCQ00894643) (RETAIN Tip H001154)
 - Fixed an issue where BBU status says optimal but firmware logs indicate that the BBU has failed (SCGCQ00838052) (RETAIN Tip H214857) 
 - Fixed an issue where importing a foreign configuration may fail after reconstruction on 4k sector drives (SCGCQ00830109)
 - Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350)
 - Fixed an issue where MR firmware reports "no SMART" error when attaching a PFA drive (SCGCQ00839455)
 - Fixed an issue where the firmware may hang (enter MonTask) when a guest OS is powered on or off in VMWare (SCGCQ00854914)
 - Fixed an issue where setting the learn cycle property of iBBU09 gives an I2C error (SCGCQ00831315)
 - Fixed an issue where "Prepare for Removal" does not work on a PD when drive erase is in progress (SCGCQ00811219)
 - Fixed an issue where MSM displays "The requested command has invalid arguments" error message if 'Schedule Consistency Check' is selected (SCGCQ00852649)
 - Fixed an issue where cache memory size in iMR is not showing 0 (SCGCQ00838893)
 - Fixed an issue where an incorrect MFI_STAT_PD_TYPE_WRONG error is returned by the firmware when PDs with different block size are mixed (SCGCQ00840251)
 - Fixed an issue where the controller reports cache memory size as 0 when no logical drives are present (SCGCQ00837600)
 - Fixed an issue where concurrent consistency check cannot be started after issuing "setfactorydefaults" command (SCGCQ00839437)
 - Fixed an issue where uEFI may report LSI EFI driver "Unhealthy" or "Failed" when more than 64VDs are configured (SCGCQ00831006)
 - Fixed an issue where functional level reset was not properly showing as unsupported (SCGCQ00854343) 
 - Fixed an issue where the legacy CTRL-H utility may report the wrong PCIe slot number (SCGCQ00799339)
 - Fixed an issue where the legacy OpROM may show an expander as a JBOD drive in POST (SCGCQ00809682)
 - Fixed an issue where an encrypted JBOD may be presented to the system in encrypted form even though password was entered incorrectly (SCGCQ00808086)

Enhancements:
 - Added ability to determine SuperCap revision ID when VPD is not programmed (SCGCQ00828990)
 - Added support for SES RQST_OK deassertion for customer proprietary JBOD SEP (SCGCQ00834321)
 - Added feature to enable support for detecting CPLD code version (SCGCQ00840631)
 - Added feature to enable drive fault LED to be lit when a known-bad drive is connected to the controller (SCGCQ00858142)
 - Added feature to turn on drive Fault LED when the controller detects a drive that was previously marked Bad (SCGCQ00858140)


Version 23.33.0-0018 -  High Impact/High Probability of Occurrence
--------------------
Fixes:
- Incorporated MegaRAID FW stack 5.13
- Fixed an issue where drive temperature cannot be displayed for a drive in Failed or Foreign state (SCGCQ00693959)
- Fixed an issue where after creating an LD via StorCLI or MSM the firmware writes into saved power condition mode page (0x1a) of all PDs in the LD and enables their idle timers (SCGCQ00658701)
- Fixed an issue where Patrol Read would sporadically correct the same defective LBA repeatedly (SCGCQ00729591)
- Fixed an issue where importing a Foreign array onto a new controller may fail with "Cannot force emulate VD to 512E since enable512Esupport is false" error in firmware log (SCGCQ00721106)
- Fixed an issue where the controller may enter MegaMon sporadically (SCGCQ00776409)
- Fixed an issue where MSM may not report a Full Initialization Aborted error until system rebooted (SCGCQ00759100)
- Fixed an issue where the firmware may allow the OS to change VD cache settings (SCGCQ00842350)
- Fixed an issue where Link Speed may show UNKNOWN when attaching a 3G or 6G SATA drive (SCGCQ00803522)
- Fixed an issue where StorLib may return 0x00ff (fail) code even though operation succeeds when creating a VD out of an existing drive group (SCGCQ00827685)
- Fixed an issue where format process of SSD may take much longer than in previous firmware (SCGCQ00674388)
- Fixed an issue where controller must have cleared config to enable 240VD unless existing config only included single-drive RAID0 VDs (SCGCQ00559643)
- Fixed an issue where some commands would timeout with CDB=ff ff ff ff (SCGCQ00459760)
- Fixed an issue where slot ordering in iMR mode might differ from slot numbering in MR mode (SCGCQ00559274)
- Blocked CacheCade deletion when multiple CacheCade volumes are associated with Virtual Drives (SCGCQ00830977) (RETAIN TIP H214323)

Features/enhancements:
- Added support for 512e drives (SCGCQ00425363)
Enhanced Event Log to include CVPM health details after every Learn Cycle to allow closer monitoring of CVPM health (SCGCQ00819877)
- Implemented a retry for reads of CVPM data to avoid erroneous event 386 or 150 in the Event Log (SCGCQ00392439)
- Added ability for firmware to report the temperature for all SAS/SATA HDD/SSD (SCGCQ00490819)
- Implemented ability for firmware to read drive temperature immediately following SAS discovery (SCGCQ00602573)
- Added ability to clear the MaintainPdFailHistory (SCGCQ00474559)
 
Version 23.22.0-0024
--------------------