Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): Flex System x440 (7167, 2590) |
Targeted Operating System: SLES12SP3 |
YUM Repository Build Date: 2020_03_18 |
Device: |
IBM Flex System FC5054 4-port 16Gb FC Adapter |
![]() Device Product Guide |
Part Number: 95Y2391 Feature Code: A2N5 |
|||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x10DF PCIe Sub Device ID: 0xE282 |
Release History: |
Change History Documents |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 12.2.349.8 - Release 19A | 19a-lp16-12.2.349.8-2 | ||
Drivers | Driver Name | Discreate Package Download | Version |
InBox Driver provided by Linux Distro install supported |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 12.2.349.8 - Release 19A | 19a-lp16-12.2.349.8-2 | ||
Drivers | Driver Name | Discreate Package Download | Version |
InBox Driver provided by Linux Distro install supported |
Firmware | Firmware Name | Version | |
---|---|---|---|
Emulex HBA (LPe1600x) Firmware Update for Linux - 11.4.329.55 - Release 18A | 18a-lp16-11.4.329.55-10 | ||
Drivers | Driver Name | Discreate Package Download | Version |
elx-lpfc-vector-map enablement code |
elx-vector-map-1-1.sles12sp3.x86_64.rpm | 1 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.329.63_k4.4.103_ 6.38-1.sles12sp3.x86_64.rpm | 11.4.329.63_k4.4.103_6.38 | |
elx-lpfc-kmp-default enablement code |
elx-lpfc-kmp-default-11.4.142.28_k4.4.73_ 5-1.sles12sp3.x86_64.rpm | 11.4.142.28_k4.4.73_5 |
Release 20A Change History Documents |
======================================================================== Emulex 16GB Gen5 Fibre Channel Firmware Package ======================================================================== This update package is applicable to the following HBA models: 95Y2386 - IBM Flex System FC5052 2-port 16Gb FC Adapter - PCI SSDID: E202 95Y2391 - IBM Flex System FC5054 4-port 16Gb FC Adapter - PCI SSDID: E282 81Y1655 - Emulex 16Gb FC Single-port HBA for IBM System x - PCI SSDID: E203 81Y1662 - Emulex 16Gb FC Dual-port HBA for IBM System x - PCI SSDID: E204 7ZT7A00521 - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter - PCI SSDID: E288 7ZT7A00522 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter - PCI SSDID: E289 For installation instructions, see the Install Tip file which is provided in the downloaded software package. NOTE: This document is designed to be cumulative. The current version is appended to the previous version(s). ========================================================================== Severity Definitions: Critical: Unable to use the solution resulting in a critical impact to operations. Includes high severity vulnerabilities. Suggested: The solution can be used with some functional restrictions resulting in minimal impact to business. Includes medium and low severity vulnerabilities. Initial: Initial release of the solution. ========================================================================== ========================================================================== Version 12.2.349.8, Build ID [19A], Severity [Critical] Release Date [ June 03,2019 ] ========================================================================== -------------------------------------------------------------------------- 1.0 Overview -------------------------------------------------------------------------- OS Versions supported o Red Hat Enterprise Linux Server 7 Update 6 o Red Hat Enterprise Linux Server 8 o SuSE Linux Enterprise Server 12 SP4 o SuSE Linux Enterprise Server 15 o SuSE Linux Enterprise Server 15 SP1 o VMware ESXi 6.5 Updateo VMware ESXi 6.7 Update o Windows 2016 o Windows 2019 Supported configurations can be found on the Lenovo Operating System Interoperability Guide at the following website: https://lenovopress.com/osig -------------------------------------------------------------------------- 2.0 Prerequisites and dependencies -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 3.0 Security Fixes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 4.0 Other Fixes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 5.0 Enhancements -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 6.0 Other Changes -------------------------------------------------------------------------- none -------------------------------------------------------------------------- 7.0 Limitations -------------------------------------------------------------------------- none =============================================================================== Firmware Version: 11.4.329.55 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Intermittent issue with NetApp where host port does not discover the SANboot LUN and the host port on the switch appears to get stuck as G-port (219985) Incremental Interoperability: - RHEL7 Update 6 Support - SLES12 SP4 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.329.13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - SLES15 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.329.13 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 5 Support - RHEL6 Update 10 Support - SLES12 Update 3 Maintenance Update Kernel Support - VMware ESXi 6.7 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.4.168.11 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - RHEL7 Update 4 Support - SLES12 Update 3 Support - This firmware is not supported on legacy IBM "Blue" servers Known Issues: - None =============================================================================== Firmware Version: 11.2.209.29 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Addressed several cosmetic issues with xClarity Administrator Incremental Interoperability: - RHEL6 Update 9 Support - Lenovo Flex platforms (Machine Types: 7X15,7X16,7X17) - Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter-Option: 7ZT7A00521 - Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter-Option: 7ZT7A00522 Known Issues: - None =============================================================================== Firmware Version: 11.2.209.19 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Link speed is now consistent across applications and boot - Stability issues addressed for XClarity firmware download Incremental Interoperability: - Windows 2016 Support - VMware ESXi 6.5 Support Known Issues: - Beginning with software release 11.2, Emulex LightPulse adapters and OneConnect adapters have independent software kits. The "Broadcom Software Kit Migration Guide" document provides special instructions and considerations for using the driver kits for LightPulse and OneConnect adapters. https://docs.broadcom.com/docs/12378907 =============================================================================== Firmware Version: 11.1.152.21 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Performance enhancement (191080) - UEFI FC BIOS showing wrong target name under Discovered Targets list(188383) - UEFI HII menu does not force reboot on changing the boot parameters (188721) - OneCLI tool settings not proliferating to BIOS Setup Menu (190894) - Improved direct attach/point-to-point target interoperability in x86 BIOS Incremental Interoperability: - None Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 11.0.270.24 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Auto Speed Negotiation not Always Negotiating to Highest Speed (154590) Incremental Interoperability: - Greater than 254 FC vport can now be created under Windows 2012R2 and Windows 2008 R2 (173657) - Avago branded transceivers no longer throw errors when plugged to Emulex HBAs (186049) - Generate SFP event notifications for presence detection and removal/insertion conditions (158278) Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.6.228.36 Supported On: Lenovo System x Rack and Flex Problems Fixed: - Implemented warning threshold in PLDM temp PDR of LP16 FC adapter (185825) - Link went down after performing port bounce/link toggle in OS (184348) Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.6.228.14 Supported On: Lenovo System x Rack and Flex Problems Fixed: - None Incremental Interoperability: - This software/firmware is only supported with Lenovo Branded System BIOS - xClarity firmware download on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.4.303.3 Supported On: System x Rack Problems Fixed: - VF speed is showing wrongly in ethtool and Ocm. - Firmware download using ethtool -f command is failing with opcode 172-1 failed:status 100-208 - Can not set the DelayDeviceDiscovery to Max (255) by ASU tool - Ports intermittently logging in to Brocade switch as G-Port Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.3.137.0 Supported On: Flex Problems Fixed: - Blue screen after firmware flash to with virtualized WWPN Incremental Interoperability: - xHMC event notifications on specific platforms (requires minimum IMM version-please consult Lenovo on the co-requisite) - Lenovo branded versions of formerly IBM branded products Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.3.83.7 Supported On: Flex Problems Fixed: - None Incremental Interoperability: - Grantley based ITE Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.2.377.18 Supported On: System x Problems Fixed: - Link does not recover during IO + Port Cycling with FW 1.1.43.3 - BIOS versions return multiple values - LPe16k point to point (direct attached) connection not bootable in legacy BIOS - LPe16k point to point (direct attached) connection performance issues in legacy BIOS Incremental Interoperability: - Grantley Rack Servers Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.2.261.36 Supported On: IBM System x and Flex Problems Fixed: - Server will halt on black screen during rolling reboot of Windows 2012 x64 uEFI SANboot - Server intermittently fails to boot during rolling SANboot (any OS) - Fixed a boot hang associated with server BIOS change - Reported firwmare version in CMM is intermittently incorrect - Unable to set pause Flow control when connected to DCBX switch with PFC off - during cable pull testing a 40 second delay in link up experienced with Brocade switch ports - I/O completion and abort completion WQE are generated out of order - Unexpected WCQE in RQ CQ seen in RXRI mode while performing cable pulls Incremental Interoperability: - Inventory support for the Flex xHMC (Chassis Hardware Management Console) - Crosslink & Express Lane on LPe16k based solutions Known Issues: - To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here.(159504) =============================================================================== Firmware Version: 10.0.803.8 Supported On: IBM System x Problems Fixed: - EFI BOOT fail during SLES11 SP3 rolling reboot Incremental Interoperability: - None Known Issues: - None =============================================================================== Firmware Version: 1.1.43.21 Supported On: IBM System x Incremental Interoperability: - None Problems Fixed: - Server will halt on black screen during UEFI rolling reboot reboot cycle test with 16Gb HBA under Windows 2012 x64 - Allows installing and booting from an MSA2040 array configured in PT-PT direct mode at 16G speed. We're now able to enable Autoscan and install/boot from multiple OSes - Added support to bypass configuring pnp Boot Table in a multipath situation. Fixes Microsoft Windows Server 2008 bug. - Fixed the "Read Rev Failure" issue during POST to accept "0" address value as a valid. - Fixed the wrong VPD HBA model number display on the banner and properties, and change the proper VPD data field size. - Fixed the timeout issue on Flogi when try to select a HBA device without connecting to a target or FC switch. - System will halt during reboot cycle test under Windows 2012 x64 UEFI - Fixing PCI Function Number decoding issue in BOFM code - Boot fails during SLES11 SP3 rolling reboot - Enable BFS and update the NVRAM if BOFM target is available - Add Diagnostic support for UEFI 16Gb FC - Reconnect menu item causes a System BIOS exit request only on AMI core system BIOS - Adding port's protocol name and WWPN in browser help menu Known Issues: - None =============================================================================== Firmware Version: 1.1.43.12 Supported On: IBM System x and Flex Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - FC support for support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter - Direct PT - PT connections - Extended SCSI Pass Thru Protocol - IBM Tape unit interoperability - see SSIC for more information - SLES 11.3 on IBM System x Problems Fixed: - Windows 2012 OS will not resume from Sleep mode - Boot Device entries can be lost after exiting from BIOS setup Known Issues: - None =============================================================================== Firmware Version: 1.1.43.3 Supported On: IBM System x Incremental Interoperability: - VPD-W for Lancer Problems Fixed: - Emulex FC Adapter does not auto-enable SAN boot mode when boot target configuration is made via IFM Known Issues: - None =============================================================================== Firmware Version: 1.1.21.9 Supported On: IBM System x Incremental Interoperability: - IBM Server machine types. Refer to IBM ServerProven for specifics Problems Fixed: - Fixed FCP_CONF handling bug - No SRR sent after drop write data frame, I/O fails - Adapter does not invoke recovery after dropped read data frame - I/O throughput performance improvements - Link failover when connected to FC Tape - Cosmetic: Cleaned up miscellaneous error handling messages in debug log files - If a new device comes online and attempts to acquire an AL_PA after the link has already come up, the FC link appears to hang until the cable is pulled - Cleaned up link negotiation at 4GB/8GB/16GB speeds with specific switches Known Issues: - None =============================================================================== Firmware Version: 1.0.11.108 Supported On: IBM System x - Initial Release ===============================================================================
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2020 Lenovo. All rights reserved |