Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SR655 (7Y00, 7Z01)
Targeted Operating System: SLES15SP2
YUM Repository Build Date: 2022_06_10

YUM Repository Release Version: 22B

Device:
ThinkSystem 430-16e SAS/SATA 12Gb HBA

Device Product Guide

Part Number: 7Y37A01091
Feature Code: B31G
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0203


Release History:

Release Change History Documents

ThinkSystem 430-x SAS/SATA 12Gb HBA update BIOS and Firmware (For Linux)



ThinkSystem 430-x SAS/SATA 12Gb HBA Firmware and BIOS Update

Supported Adapters:  
	ThinkSystem 430-8i SAS/SATA 12Gb HBA   (7Y37A01088)    
	ThinkSystem 430-16i SAS/SATA 12Gb HBA  (7Y37A01089)    
	ThinkSystem 430-8e SAS/SATA 12Gb HBA   (7Y37A01090)       
	ThinkSystem 430-16e SAS/SATA 12Gb HBA  (7Y37A01091)       
	ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA  (NA-StarkSASHBA)  
	
	
NOTE TO SERVICE - Reference RETAIN #N/A

Version  20.01.00.00
 --------------------
    BIOS            Firmware          UEFI Driver   
9.39.00.00       20.00.04.00           20.00.01.00

Defects:
Imbalanced bandwidth performance with 2 x4 expanders connect to Aero IT controller(DCSG00950631
 Blue Screens while collecting "pl dbg" logs(DCSG00984451
 UBM statistics data collection and UBM error handling fixes(DCSG00975065
 Fault 0x070A observed while performing firmware downgrade.(DCSG00758163
 Ventura/Mercator: pl: 4311 fault(DCSG00918020
 Two elements of SES Page A are assigned same slot number for UBM backplanes with x2 DFC(DCSG00966202
 Hot add drive on UBM backplane with x2 or X4 DFC reports incorrect element status in SES Page 02h(DCSG00967012
 Response to OOB command is not sent on Internal Dynamic Memory Allocation failure(DCSG00906577
 BST: invalid syntax for Uart config(DCSG00957157
 [Aero][UBM] Enhance the link configuration to handle the link speeds for SAS/SATA drives behind UBM.(DCSG00552897
 Update SSUTimeout Fields Value in BIOS Page 1 to 0xF0(DCSG00982364
 Critical Error Log created if the Firmware Download of BIOS using BIOS image from different package than Firmware.(DCSG00951807
 Fault 0x7600 observed when 1 phy is disabled in SAS IO Unit page 1(DCSG00788430
 Drives not discovered when an enclosure is hot plugged after removing a PCIe switch based JBOF(DCSG00957168
 Unsupported MPI Config page read from OOB provides data in response(DCSG00937617
 SPDM lib compile error for Ventura build(DCSG00810786
 SPDM key reading failed when complete flash Erase case(DCSG01032600
 Coverity : Remove dead code(DCSG00982343
 VSES : Multiple elements of SES page 0xA are assigned the same slot number(DCSG00973316
 pl: NVMe: Format Unit FMTDATA bit should be ignored(DCSG00063448
 PL NVMe : IOs fail with SGL length shorter than the transfer legth(DCSG00501518
 Performance drop seen with direct attached SAS/SATA drives(DCSG00980873
 [BST] Topology information parsing using FW Diag commands is failing(DCSG01045324
 pl: backend PCIe: PCIe error handler fails to issue task management with cascading errors(DCSG00839445
 FW BST: Larger size IO jobs take more time to start, triggering timeout exception in SAL(DCSG00961165
 BST: Fix scripts for SAL stability.(DCSG01012237
 Performance drop seen with SAS/SATA drives in Windows using latest driver(DCSG00981706
 Update Version Field value in Std Inquiry Data of vSES Device(DCSG00966397
 Enclosure handle for some direct attached device might be wrong during Event replay for direct attached slot order case.(DCSG00381441
 Data length from host to DA-SEP device not checked if it is more than buffer length in firmware(DCSG00915992
 [BST] SEP locate test fails on Atlas attached NVMe drives(DCSG01039953
 [Aero][PLDM] PLDM Timer restart failing(DCSG00430198 (Port Of Defect DCSG00830822)
 Controller Faults when connected to DA SEP Backplane(DCSG00916381 (Port Of Defect DCSG00918045)
 [Aero] Phase 18 build error fix(DCSG00708175 (Port Of Defect DCSG00708188)
 Bad PHY events generated by RAID stack for invalid VSES elements slot with Critical status(DCSG00925970 (Port Of Defect DCSG00927932)
 FW Fault 2622 observed during system boot up in some new Gen4/Gen5 servers(DCSG00947451 (Port Of Defect DCSG01019237)
 HBA hangs on boot with failed UBM backplane in a multi-UBM backplane topology(DCSG00653774 (Port Of Defect DCSG00707457)
 Fixed fault 0xF000 when doing VSES task management(DCSG00927996 (Port Of Defect DCSG00934187)
 Some drives missing in OS when Direct attached slot order event replay flag is set in NVDATA(DCSG00991409 (Port Of Defect DCSG00996086)
 Some drives and enclosures not added to Windows OS when SAS/SATA devices are reduced in NVDATA.(DCSG00654062 (Port Of Defect DCSG00757561)
 Fault 0xEE19 observed while running lane break test with managed switch attached to controller.(DCSG00939163 (Port Of Defect DCSG00947866)
 (SATA Only) IO Timeouts seen while running Unmap, SATA Passthrough and Read/Write IOs to a SATA drive(DCSG00654439 (Port Of Defect DCSG00831920)
 MCTP : MCTP MPI requests are failed with drive missing status even when drive is present(DCSG00952803 (Port Of Defect DCSG00956655)
 [Aero][OOB] Firmware download in loop from OOB in PCIe mode fails(DCSG00555977 (Port Of Defect DCSG00831123)
 SATA : one or more HDD are not discovered by OS when drives behind expander are powered ON(DCSG00947126 (Port Of Defect DCSG00964427)
 pl: SAS IO Unit Page 1 Write Current may not cause phy to be enabled(DCSG00654031 (Port Of Defect DCSG00734511)
	
EnhancementRequests:	
 BST: Bring up new Aero activity BST server at BLR(DCSG00323525
 BST: Update boardnames in configuration data(DCSG01010542
 Connector Order change for 9502-16e controller(DCSG00966344
 Create Partial XML for 9502-16e HBA(DCSG00930106
 MPI 2.6: Header file changes associated with revision 2.6.11(DCSG00293141
 pl: backend PCIe: target link speed diag command(DCSG00757333
 Add support for FW UART console to BST scripts(DCSG00776933
 Code Coverage improvement for managed switch SES stack(DCSG00949284
 SNTL Code coverage Improvement(DCSG00949306
 BST: Add custom Cardnames to BST UART configuration(DCSG00985842
 Code Coverage improvement for managed switch MPI device stack(DCSG00949285
 Release Automation: Check for failure during baseline creation(DCSG00958012
 [BST] Graceful handling of controller reset scenario(DCSG01027037
 SAS phy port configuration of UBM connected phys based on UBM DFC Link width.(DCSG00927212
 [OEM][BST] Add a new OEM server to BST(DCSG00776916
 PL SATL : Add SAT translation for the Concurrent Positioning Ranges VPD page(DCSG00927210
 PL SATL : Update the WRITE SAME command to account for Zoned Block Devices(DCSG00500552
 Remove SASPARSER binary from Release Order(DCSG00957868
 Release Automation: automate rebase operation for phase specific streams(DCSG00950531
 UBM error handling improvements and debug statistics data collection(DCSG00903198
 Add cable breaker support to BLR test Hosts(DCSG00777063
 BST: Replace Python's telnet lib APIs with invocations of native telnet client(DCSG01008755
 Integrate MPI 2.6.11 headers(DCSG00408836
 cable breaker exception handling and support for array controller(DCSG00086796
 SATL : ATA Passthruough command handling when Datalength in MPI < data requested to drive(DCSG00833193
 BST: Update Enclosure Logical ID for BST setups(DCSG01015576
 [BST] Add SEP related test cases(DCSG00949307
 [Aero][BST] Improve the code coverage of file plPciDeviceManager.c(DCSG00947724
 Update SAS 3.5 FW summary release notes(DCSG00979878
 [Aero][BST] Improve the code coverage by adding new test cases(DCSG00948894
 CFGI: Integrate MPI 2.6.11 headers with CFGI Lib.(DCSG00481628
 Update 9500-16i, 8i channel XMLs to support new VPP backplane management device address.(DCSG00351950
 BST: Add locate PD test cases to UBM BST(DCSG00019759
 PL SATA : Read logpage 12 and 13 during SATA initialization to get features supported for NCQ encapsulation using FIS porting(DCSG00779724
 PL : Remove obsolete workarounds(DCSG00008204
 BST: On IO errors, retry IO after some delay(DCSG01029567
 Enable collection of PCIe Link event "RECEIVED_NAK_DLLP" (EventCode=0x08) by default(DCSG00122084
 SPDM feature compile out from FW code(DCSG00707071
 [Aero] Enable UBM detection logic on all connectors for OEM HBA with SEP_PRESENT GPIOs(DCSG00927207
 Release Automation: Assign release type when creating ROP(DCSG00941419
 Support streaming of debug logs (HTB) via I2C OOB band on Ventura/Aero IOC/HBA (Part B)(DCSG00927213
 [BST]Add support to execute scripts for one specific card(DCSG00961877
 [UBM] Add detection of SAS/SATA drive with UBM backplane supporting IFDET2# and PRSNT#(DCSG00945423
 Blackduck: Remove non UTF-8 encoding characters from source files(DCSG00258258
 Add 9502-16e board Nvdata to Aero ROP(DCSG00966467
 Code Coverage improvement for NVMe SGL analysis and translation stack(DCSG00949287
 Support downloading of the Host-based Trace Buffer (HTB) via MCTP OOB Interface on Ventura/Aero IOC/HBA (Part A)(DCSG00500554
 BST: When comparing slot numbers, ignore the strings from eminfo command output(DCSG01007045
 BST CodeCoverage : Add BST test case to improve MPI task management code coverage(DCSG00999219
 [Aero][PLDM] Platform changes to accommodate latest PLDM baseline(DCSG00447989 (Port Of EnhancementRequest DCSG00500775)
 SEKM Support for IT controllers(DCSG00433132 (Port Of EnhancementRequest DCSG00777312)
 SEKM: Prevent firmware Download of firmware that do not support SEKM when SEKM is enabled.(DCSG00549524 (Port Of EnhancementRequest DCSG00816022)
 Error handling of UBM CHANGE_DETECT# signal(DCSG00962565 (Port Of EnhancementRequest DCSG00963253)
 [SPDM] Blocking slots 1-7 from configuring SPDM certificates(DCSG00500296 (Port Of EnhancementRequest DCSG00507210)
 Reintroduces the previous security page as MR_MPI26_CONFIG_PAGE_SECURITY_1 to align with current NVDATA(DCSG00977495 (Port Of EnhancementRequest DCSG00977500)
 SEKM feature enhancements to handle error scenarios(DCSG00777328 (Port Of EnhancementRequest DCSG00903186)
 Enhance Error scenario handling in SEKM Feature code(DCSG00966411 (Port Of EnhancementRequest DCSG00974796)


Version  18.04.00.00
 --------------------
    BIOS            Firmware          UEFI Driver   
9.35.00.00       18.00.03.00       18.09.01.00
Fix issue:
-Disk cannot be detected after the driver of CFF 440-16i is loaded during installation Windows 2022

Version  18.03.00.00
 --------------------
    BIOS            Firmware          UEFI Driver   
9.35.00.00         18.00.02.00       18.09.01.00
Fixes:
we already have the fix for the EFI driver to properly observe the SSUTimeout in 18.01.00.00, 18.02.00.00 and now 18.03.00.00.
The only difference now between 18.02.00.00 and 18.03.00.00 now is the NVDATA setting the SSUTimeout to 60 seconds.

Version  18.02.00.00
 --------------------
    BIOS            Firmware          UEFI Driver   
9.35.00.00         18.00.02.00       18.09.01.00

Defects:
-Coverity defects fix.(DCSG00340836
-PL SATA Only : SATA PFA drive is not recognized as PFA drive in Aero while hot-plugging(DCSG00427743
-Some drives and enclosures not added to Windows OS when SAS/SATA devices are reduced in NVDATA.(DCSG00654062
-Ring buffer decoder GUI hangs if timestamp is invalid(DCSG00437238
-[NVMe] Firmware download in mode E failed with error Invalid Firmware Image(DCSG00313245
-[Code Review] Updated CoreDump related data structures to have capitalized first letter for the member fields(DCSG00250948
-pl: NVMe: chain to PRP SGL for non-read/write IO may be handled improperly(DCSG00408313
-[NVMe] Send diagnostic to abort background test completes with success when no background test started.(DCSG00310330
-[NVMe] Inquiry command to NVMe device reporting old rev firmware after drive firmware update completed successfully(DCSG00321504
-SPDM IT:SPDM BMC bring up on P2 server(DCSG00238540
-SPI LIB 1 - Manual Flash writes to flash parts connected to chip selects other than 0 fail.(DCSG00350016
-PLDM Type 2 - Change debug print filter level to "Warning" for PollForPlatformEventMessage command(DCSG00263767
-Aero: PL with newer Atlas FW (4.2) has extra slot number in the Atlas enclosure(DCSG00284238
-Format Repair operation fails on certain NVMe drive(DCSG00408635
-Ventura/Mercator: pl: direct attached SAS or SATA device may not be discovered(DCSG00408109
-SPILIB: NVSRAM uses old ASENB command(DCSG00342936
-[NVMe] Protect bit is always set in standard inquiry data for NVMe drives.(DCSG00301661
-README file mentions sas2parser instead of sasparser(DCSG00394150
-PL SNTL : Accumulated Power On Hours value reported by LogSense translation is byteswapped(DCSG00499729
-[NVMe] SCSI TUR command fails when sent to a NVMe drive with corrupted LBA 0(DCSG00299624
-[Ventura] Some NVMe drives are not discovered(DCSG00301612
-SPILIB: FIx definition of SPI_LIB_TYPE for SPILIB1(DCSG00354885
-SPILIB2: Some properties functions access the wrong array(DCSG00340954
-[NVMe] Send diagnostic with self test bit 1 but selftestcode non 0 is not failed.(DCSG00306498
-Move Version control files to folder for Release BST(DCSG00342866
-[NVMe] Mode Select command to write Read Write Error recovery page fails.(DCSG00307175
-[VSes] Connector name of the VSes device in SAS device page 0 has invalid data if no device is connected to port 0(DCSG00383998
-Doxygen build error(DCSG00415793
-[Aero] Phase 18 build error fix(DCSG00708175
-PLDM - Fix compilation errors reported in an OEM platform(DCSG00382501
-BST: ScrutinyCli invoked with invalid options(DCSG00428615
-Fixed PH17 Coverity issues(DCSG00335212
-[NVMe] PL Fault 0xE429 is seen while performing reset for certain NVMe drive.(DCSG00395750
-PLDM Type 2 - Fail module initialization if Managed Device invokes initialization API without allocating memory(DCSG00360498
-pl: NVMe: status code type not checked upon Write Buffer callback(DCSG00419779
-Coverity found defects for converting an expression to a narrower type in SATL code.(DCSG00297461
-[Ventura][NVMe] Phy disable from application does not removed the drive from PL.(DCSG00384856
-PL fault: Invalid Msg Frame fault triggered on external card connected to UBM BP(DCSG00408493
-Uninitialized pointer access in UBM code.(DCSG00446918
-[VSes] SCSI State not correctly set for some error response to SCSI commands.(DCSG00312554
-[NVMe] Extended Self Test Completion time in Control mode page is byte swapped(DCSG00308453
-Trigger script with PassComponentTable Command set to invalid Value led to rolling PLDM error messages(DCSG00500454
-pl: NVMe: async event handler proceeds during IO quiescing(DCSG00431716
-Fix coverity reported defects(DCSG00282926
-[NVMe] Parameter Code in Self Test Results log page is incorrect.(DCSG00422250
-Element Status code of a Slot in SGPIO BP with no drive marked as 'Unknown'(DCSG00428815
-fixed the parameter difference for the PLDM Type 5 print framework.(DCSG00286651
-AXI access errors causing FW asserts or faults due to invalid SATA passthrough commands(DCSG00215338
-pl: SAS IO Unit Page 1 Write Current may not cause phy to be enabled(DCSG00654031
-[NVMe] TSD bit not getting set in Reference Temperature log parameter(DCSG00430063
-MBEDTLSLIB: Compile out Mbed TLS Self-Test code(DCSG00335755
-PLDM single firmware update logs multiple debug messages in controller trace buffer(DCSG00258279
-Update SBLIB version in BST version file(DCSG00316342
-Update the Driver Trigger Page data structs' size and add padding to make them 256 bytes(DCSG00258095
-Performance drop of 5-9% seen with Random Read/Write IOs to NVMe drives.(DCSG00258412
-Issue in freeing PLDM firmware update resources(DCSG00317911
-SPILIB2: Small misaligned transfers sometimes result in a read-back verify failure on page writes(DCSG00283387
-[SPDM IT] Return actual size of certificate chain content to SPDM LIB(DCSG00233805
-OOB-MCTP over I2C - FW updates in Loop hits PLDM Fault 0x6(DCSG00380088
-pl: backend PCIe: fix a couple of issues related to PCIe discovery and NVMe init(DCSG00355408
-NVMe Repair Operation hangs on a certain NVMe drive with Multiple Namespace(DCSG00415462
-Release Automation: If release job web page takes more than 60 secs to load, script throws exception(DCSG00297363
-Fix Coverity issues(DCSG00293500
-MAC verification failed due to inconsistent secure ID(DCSG00309854
-pl: Incorrect c0 values displayed for SAS/SATA in the "pl serdes tx" output(DCSG00422289
-NVMe : PROTECT bit in inquiry data is set.(DCSG00308451
-Aero: HW Workaround - When Aero is in the L1 state it periodically (every 2 ms) transitions to L0 and back to L1(DCSG00501537
-VSES getting removed in OS on controller reset.(DCSG00301631
-[Aero] SAS SATA only partial nvdata xml are not included in release order.(DCSG00394146
-SPDM Authentication fails when BMC re-triggers SPDM Handshake(DCSG00547436
-[NVMe] Mode select command to set Control Mode page with last two bytes changed completes successfully.(DCSG00315331
-pldmFreeFwUpdtResources() doesn't frees RetryRqstTimer correctly.(DCSG00313887
-Fix Coverity tool reported defects(DCSG00266270
-PL Backend PCIe : SATA drive discovery is delayed(DCSG00310045
-Assertion failure in fw\cpu\arm\exceptions.c at line 1006 on triggering QueryDeviceIdentifier command in Download State(DCSG00337907
-SPDMIT: Return appropriate error to SPDM Lib when read certificate from security page 0 fails(DCSG00299079
-[NVMe] The long LBA bit is not set in Mode Parameter header.(DCSG00319580
-Coverity issue(DCSG00293875
-PL Fault 0xEA11 observed, while upgrading Atlas FW using StorCLI in presence of bad NVMe PD's present in the Atlas.(DCSG00324838 (Port Of Defect DCSG00340935)
-[Aero] Controller missing in System Bios.(DCSG00411545 (Port Of Defect DCSG00420098)
-SATA Only: Command timeout observerd on SATA drives(DCSG00344039 (Port Of Defect DCSG00356008)
-Ventura/Mercator: pl: 4311 fault(DCSG00918020 (Port Of Defect DCSG00929451)
-Out of bound memory access when assigning dma group for controller devices.(DCSG00243152 (Port Of Defect DCSG00243641)
-Observed PL Fault 6231 while running IOs along with Expander phy link reset.(DCSG00363807 (Port Of Defect DCSG00373461)
-Device add/remove event sent with wrong enclosure handle in certain multi VSes topology.(DCSG00350248 (Port Of Defect DCSG00380548)
-EID is not assigning back with IT controller restart(DCSG00394045 (Port Of Defect DCSG00397565)
-PL NVMe : PCI task management is not getting completed.(DCSG00231422 (Port Of Defect DCSG00266053)
-During OS reboot some drives go missing.(DCSG00354770 (Port Of Defect DCSG00361759)
-System bios hangs during initial drive discovery.(DCSG00312551 (Port Of Defect DCSG00382416)
-HII Refresh Topology Hangs when connected to Faulty SES Device(DCSG00385938 (Port Of Defect DCSG00404446)
-Enclosure ID of some Switch attached NVMe devices missing after system reboot.(DCSG00414735 (Port Of Defect DCSG00426692)
-(SATA Only) IO Timeouts seen while running Unmap, SATA Passthrough and Read/Write IOs to a SATA drive(DCSG00654439 (Port Of Defect DCSG00906897)
-[SATA Only] SCSI Start Stop Unit command with power condition active fails.(DCSG00349970 (Port Of Defect DCSG00353138)
-0x6001 Fault running TMs with certain NVMe translated Host IOs(DCSG00362831 (Port Of Defect DCSG00385767)
-Drives connected behind external card with VSES disabled, failed to detect in Linux OS(DCSG00350402 (Port Of Defect DCSG00363785)
-Firmware fails to send Enclosure removal event to host when the enclosure is removed from the topology.(DCSG00232962 (Port Of Defect DCSG00244617)
-[Aero/Ventura] Bootloader corruption with firmware download and DC cycle in loop.(DCSG00238233 (Port Of Defect DCSG00245454)
-ParentDevHandle value calculated for given Phy Number is incorrect for Direct Attached Devices in Event Replay logic(DCSG00299632 (Port Of Defect DCSG00299823)
-Controller Faults when connected to DA SEP Backplane(DCSG00916381 (Port Of Defect DCSG00918083)
-[SATA ATAPI] FW fault 0x6231 seen while completing some IO for ATAPI device.(DCSG00350047 (Port Of Defect DCSG00353918)
-[Aero][UBM] Enhance the link configuration to handle the link speeds for SAS/SATA drives behind UBM.(DCSG00552897 (Port Of Defect DCSG00706402)
-PL : Missing drives during AC power cycle test(DCSG00275868 (Port Of Defect DCSG00301823)
-ExtManPage41 TX Values are not being applied / run by AERO SERDES(DCSG00311524 (Port Of Defect DCSG00311739)
-0x6001 Fault while running driver load/unload with simultaneous NVMe drive pulls(DCSG00378243 (Port Of Defect DCSG00385686)
-PL: 9460-16i incorrect slot numbers assigned attaching to OEM specific mixed mode backplane(DCSG00243953 (Port Of Defect DCSG00342787)
-[Aero][PLDM] PLDM FW discovery results in 265D Fault(DCSG00307769 (Port Of Defect DCSG00330183)
-Ventura: Faults 0x0101 and 0x5805 Invalid LMID Index Seen after hundreds of cold boots(DCSG00338118 (Port Of Defect DCSG00384000)
-Serdes TX table in pl diag dump has the Pre-cursor, Post-cursor and Attenuation values mixed(DCSG00388268 (Port Of Defect DCSG00404448)
-NVMe Init error drives are not discovered after pull/push within DMD timeout(DCSG00242197 (Port Of Defect DCSG00250023)
-ventura build issue with PL PCI DEVICE feature disabled(DCSG00286358 (Port Of Defect DCSG00286361)
-SATA only: WRITE SAME NCQ encapsulation assumes NonData NCQ is supported if Zero EXT is Supported(DCSG00398894 (Port Of Defect DCSG00412030)
-Update the SPDM print index properly before adding the prints to ring buffer(DCSG00335886 (Port Of Defect DCSG00337717)
-[NVMe] SCSI log sense command timeouts seen while running 1MB IOs to NVMe drive(DCSG00136092 (Port Of Defect DCSG00237479)
-LED Blink/Unblink operation fails on certain Slots in UBM using MPI SEP Request(DCSG00282826 (Port Of Defect DCSG00290200)
-PL NVMe : PCI task management is not getting completed.(DCSG00231422 (Port Of Defect DCSG00245537)
-[Aero][OOB] Firmware download in loop from OOB in PCIe mode fails(DCSG00555977 (Port Of Defect DCSG00908352)
-Ventura: SAS3616W or SAS3616W based boards have links less than epected width(DCSG00249594 (Port Of Defect DCSG00249753)
-[Aero][PLDM] PLDM Timer restart failing(DCSG00430198 (Port Of Defect DCSG00960384)
-Remove LogSpecific member in the structure 'IOPI_LOG_DETAIL(DCSG00318366 (Port Of Defect DCSG00318943)
-PL SATA Only : Controller hang observed for ATA Passthrough command with count value set to 0(DCSG00250952 (Port Of Defect DCSG00266833)
-PL fault 0xE40E observed accessing unconfigured MPI backend device registers through CLI cmd(DCSG00234837 (Port Of Defect DCSG00238649)
-9500-16e disappears on system reboot(DCSG00367091 (Port Of Defect DCSG00414022)
-HBA hangs on boot with failed UBM backplane in a multi-UBM backplane topology(DCSG00653774 (Port Of Defect DCSG00707464)
-OEM UBM backplane Slot status LED Blinks only for 10 secs for NVMe VDs with Toggle Host LED management(DCSG00323361 (Port Of Defect DCSG00380726)
-Controller fault observed on changing some phys to manual port config with port set to 0.(DCSG00237498 (Port Of Defect DCSG00245531)
-Aero A0: Controller faults 0xD015 with Refresh topology from BIOS in a managed PCIe switch config.(DCSG00414714 (Port Of Defect DCSG00418238)
-[Aero][PLDM] Date format exposed by IT to PLDM library is not as per PLDM spec(DCSG00363642 (Port Of Defect DCSG00398739)
-9500-16e fails to recover after warm boot(DCSG00422618 (Port Of Defect DCSG00422813)
-PL: Reply to IO's bad SGL to Atlas SES has wrong DevH and SMID's incorrectly tries to fit 3 SGEs inframe(DCSG00315476 (Port Of Defect DCSG00366033)
-[VSes] Element status set to 'Unknown' in SES page 2 of VSES for some phys where nothing is connected.(DCSG00333163 (Port Of Defect DCSG00343848)
-Make Clear of the PEPP version of ConfigValid Applicable to IT Boot Code Only(DCSG00398453 (Port Of Defect DCSG00404468)
-As part of the Device Add\Removal Event, the enclosure handle passed on by the PL FW to the upper layer is incorrect.(DCSG00298128 (Port Of Defect DCSG00299826)
-When performed export csr for all 8 slots in batch observing for few slot command is success and for other it is failure.(DCSG00421812 (Port Of Defect DCSG00425171)
-NVMe Init Error: Device with no namespaces shows 'Namespace count Invalid' as Unrecoverable Error(DCSG00290593 (Port Of Defect DCSG00303510)
-pl: backend PCIe: limit CRS retry count(DCSG00312206 (Port Of Defect DCSG00324774)
-[VSes] Slot status is reported as 'Unsupported' for drives connected to UBM backplane.(DCSG00337912 (Port Of Defect DCSG00353069)
-PL NVMe : IOs fail with SGL length shorter than the transfer legth(DCSG00501518 (Port Of Defect DCSG00735325)

EnhancementRequest:
-SPILIB2: Add support for AV1 ring buffers(DCSG00421632
-OEM Smart Carrier Backplane code cleanup(DCSG00171467
-Add new field DEPOPULATION TIME as part of translation of VPD Page - Block Device Characteristics.(DCSG00167925
-SPILIB1: CLear LC bits in Spansion, wait longer for NVSRAM(DCSG00427348
-SPDM IT: Add memory allocation/free for SPDM_LIB(DCSG00229260
-SPILIB2: Integrate 20.00.11.00 with the IT firmware tip(DCSG00297796
-pl: backend PCIe: runtime control for lane margining debug console prints(DCSG00373313
-SPILIB2: Add spi2FlashWriteDataNoVerify() API(DCSG00394830
-pl: NVMe: update to latest SNTL specification Phase 2(DCSG00340625
-[NVMe] SCSI Send Diagnostic command translation for NVMe.(DCSG00261270
-Enhancement to source of randomness for generating key pair(DCSG00208477
-MBEDTLS LIB: Add license files to source tree(DCSG00813882
-Add dumps to pl dbg(DCSG00008206
-pl: backend PCIe: CRS retry limit disable bit(DCSG00325823
-Update SAS 3.5 FW summary release notes(DCSG00384316
-SPILIB2: Add support for FLASH suspend/resume.(DCSG00371513
-PLDM Monitoring and Control: Addressed the Coverity reported issues and added abort function(DCSG00342504
-VSES: Removed loginfo code when the command is failed with a check-condition(DCSG00235941
-SPILIB2: AV2 Core Support [PA 0.2](DCSG00230517
-Update the event logging when the "CoreDump" region is erased from ScrutinyCLI command(DCSG00367325
-Summary of changes(DCSG00383538
-[IT SPDM] Parse certificate to X.509 V3 Standard and verify digital signature to affirm chain of trust(DCSG00218564
-Code cleanup activity(DCSG00395207
-SPILIB: Add support for multiple erase sizes in uniform flash parts(DCSG00309579
-[IT SPDM] Implement client APIs for SPDM Get Measurement command.(DCSG00256411
-Add version control file to build(DCSG00242260
-Address Coverity tool reported issues in PLDM Type 2 and Type 6 modules(DCSG00352028
-Ventura/Aero: Request by MegaRAID to output debug data in vtboot.rom for future debug(DCSG00420316
-VSES - UBM DFC Array Device Element status read optimizations(DCSG00347743
-PLDM Type 6 - Add support for Redfish Message Event(DCSG00255563
-Add snapdump support for PLDM Type 2 and Type 6 modules(DCSG00226303
-PLDM Type 2: Implement API changes and support for Redfish message event in PLDM Monitoring and Control module(DCSG00253011
-[NVMe] Provide interface to reset NVMe drive after shutdown.(DCSG00109904
-NVMe Sanitize Translation(DCSG00266054
-[NVMe] Update SCSI to NVMe translations based on latest SNTL document.(DCSG00235935
-PLDM - Handle a TODO related to sensor re-arm unavailable in present state and update copyright year in all Type 2 files(DCSG00404477
-SPI LIB 1- Enable Suspend-Resume support for Winbond and ISSI flash parts.(DCSG00380266
-Update the IT/PL Firmware Error codes guide(DCSG00349980
-Security Key page MPI definitions should more descriptive(DCSG00336313
-SPILIB2: Add Avenger2 Duty Cycle and Sample Delay options(DCSG00287035
-Enable 24 NVME drive support for internal and external controllers(DCSG00306646
-SPILIB: Add 1_4_4 read/write and NVSRAM commands to analyzer decoder(DCSG00358690
-SPLIB2: Eliminate debug prints from NVSRAM init(DCSG00299483
-SPILIB 2.0 : expander/Atlas Modify time loops to handle multi-processsing better(DCSG00220784
-[Ventura/Aero] Block the OOB FW download when firmware update is in progress.(DCSG00249958
-SPILIB2: Add support for 100 MHz using default configuration for Macronix 256 MBit(DCSG00409337
-Host Trace Buffer Triggers to be persistent(DCSG00235945
-Added IOCParam to IOUnit Control command to allow periodic time-sync(DCSG00235948
-[SPDM IT] Export CSR & Import Cert Open & Close Session(DCSG00221406
-SPILIB2: Add code to clear block protect bits if they are set(DCSG00420314
-SPILIB 2.0: Avenger2 and R processor build support(DCSG00230514
-Implemented linked list for entity and sensors.(DCSG00219964
-Release Automation: Add support for generating Ventura ROP(DCSG00246102
-Enhance PLDM library for separation of APIs/LIB and source code(DCSG00394996
-Aero Secure Boot: Add Key Update Pending Check for 'COMPLETE' Image Download(DCSG00241566
-[Aero/Ventura]Fix Coverty issues in Phase_18 TIP(DCSG00507240
-Support for Mode 5 NVMe drive firmware download with Chain SGL SCSI Write buffer request.(DCSG00171452
-Total vSES Enclosure Slot Count value reported is incorrect in host tools\MR FW with NVMe drive which fails initialization(DCSG00546745
-[NVMe] Prevent non Read/Write SCSI IO Timeouts while running heavy greater than MDTS RW IOs(DCSG00234748
-NVMe Init Failure Reporting & Recovery of NVMe Drive with Partial Capacity NSID 1 Namespace(DCSG00310384
-SPDMLIB: Support SPDM Challenge command request for hash of all supported measurements(DCSG00366048
-Vent/Aero: Integrate SPILIB 20.00.14.00(DCSG00317165
-Log 0 SPDM events for certificate slot & key management(DCSG00322202 (Port Of EnhancementRequest DCSG00366811)
-[Aero][PLDM] Platform changes to accommodate latest PLDM baseline(DCSG00447989 (Port Of EnhancementRequest DCSG00960360)
-VSES: Update diag page 02h status reporting for Array device elements to use UBM DFC SnC Desc Element status code(DCSG00308393 (Port Of EnhancementRequest DCSG00379789)
-[SPDM] Blocking slots 1-7 from configuring SPDM certificates(DCSG00500296 (Port Of EnhancementRequest DCSG00645950)


Version  16.09.00.00
--------------------
    BIOS            Firmware          UEFI Driver   
 9.31.00.00       16.00.11.00       16.00.08.00
Ph16

Defects:
-Ventura/Mercator: pl: direct attached SAS or SATA device may not be discovered.(DCSG00408109)
-pl: NVMe: chain to PRP SGL for non-read/write IO may be handled improperly.(DCSG00408313)
-Updated GoldenX to handle the CoreDump Region.(DCSG00042890)

Enhancements:
-For report LUN command, Increase retry count from 3 to 5 and add SCSI status BUSY into retry loop.(DCSG00930134)

Version  16.07.00.00
 --------------------
    BIOS            Firmware          UEFI Driver   
 9.31.00.00       16.00.11.00       16.00.06.00

Defects:
-SPDMLIB: Add change to SConstruct to copy library output file (*.a) to release folder.(DCSG00117832)
-CFGI : The first 32 characters of MPI defines should be unique.(DCSG00086291)
-SPDM_LIB: Add alignment parameter into SPDMLib_Calloc interface.(DCSG00237674)
-pl: backend PCIe: prevent switch rediscovery quirks.(DCSG00018730)
-NVMe Init reports wrong failure error codes.(DCSG00103993)
-Incorrect slot count is present in config, for a BP connected to external card in BST server.(DCSG00319578)
-Coverity Bugs in PL Enclosure Management Files.(DCSG00043514)
-PL: MS-SES with no Array Devices in Atlas SES causes 0x7200 fault.(DCSG00077263)
-Additional Key Data field of Security Page 1 is missed in XSD definition.(DCSG00077979)
-Unitialized pointer was being accessed.(DCSG00096545)
-Firmware fails to send Enclosure removal event to host when the enclosure is removed from the topology..(DCSG00232962)
-MBEDTLS LIB: fix compilation error during IT FW build.(DCSG00234920)
-Coverity defect fix.(DCSG00231928)
-EID is not assigning back with IT controller restart.(DCSG00394045)
-SPDM LIB: Set ECDSA signature with correct size in Signature field of SPDM Challenge response buffer before sending to BMC server.(DCSG00225192)
-NVMe Init error drives are not discovered after pull/push within DMD timeout.(DCSG00242197)
-[Aero] Application scanning for I2C devices on I2C bus hang when OOB configured to MCTP-PCIe mode.(DCSG00103208)
-BST: NumSlots fix for Ph14 &15 broke BST on other fw phases.(DCSG00315471)
-9500-16e disappears on system reboot.(DCSG00367091)
-Sea 16e PCIe TX Compliance Test Failure.(DCSG00052179)
-SPDM: Attestation failed with wrong Nonce values.(DCSG00126872)
-CFGI : MPB2 read fails with invalid checksum.(DCSG00098544)
-Duplicate slot IDs assigned for SAS/SATA drives on elrond Ex1 backplane when it is connected to 9405W 16i controller.(DCSG00072826)
-Change file name of SpdmDebug.h to SpdmDebugs.h . And Check in SpdmDebugs.h for IT.(DCSG00074556)
-Ventura/Mercator: pl: 4311 fault following SAS IO Unit Page 1 write.(DCSG00099275)
-PL: Aero -- Atlas US Cable Pull/Push Results in Missing Enclosure Slot Info.(DCSG00181448)
-PL Backend PCIe: 0xEE1A fault observed with bad clocked Aero and Atlas.(DCSG00080298)
-Coverity found defect in SATA and Enclosure management modules.(DCSG00098596)
-Coverity found defect in MPI Device and FPE modules.(Coverity found defect in MPI Device and FPE modules).(DCSG00098787)
-Controller fault observed on changing some phys to manual port config with port set to 0.(DCSG00237498)
-Ventura: SAS3616W or SAS3616W based boards have links less than epected width.(DCSG00249594)
-NVME Drives not getting discovered on inserting in Customer UBM3 x4 backplanes until OCR.(DCSG00081732)
-Make Challenge Buffer Include Get_Digest/Digest, Get_Cert/Cert.(DCSG00055393)
-[Aero][PLDM] Date format exposed by IT to PLDM library is not as per PLDM spec.(DCSG00363642)
-9500-16e fails to recover after warm boot.(DCSG00422618)
-BST: version.mak no longer a part of BST verification.(DCSG00368158)
-Correct Sblib Int make sure ER 110403 and ER 166877 are present.(DCSG00214265)
-Correct Sblib Int make sure ER 110403 and ER 166877 are present (2).(DCSG00215388)
-pl: backend PCIe: resource leakage during direct attached event generation.(DCSG00093660)
-Observed Data Corruption during IO stress test.(DCSG00212797)
-Addressing IT raise defects in SPDM library change.(DCSG00061718)
-MBEDTLS LIB: Fix dynamic memory release bug in Mbed Tls Library.(DCSG00216944)
-Aero A0: Fault D033 running IO + Expander Phy Link/Hard Resets to Expander phys.(DCSG00045450)
-[Aero][PLDM] PLDM FW discovery results in 265D Fault.(DCSG00307769)
-Phase 15 Coverity Bug Fixes.(DCSG00104982)
-Large topology of more than 500 drives cannot be supported on SAS 3.5 Channel Controllers.(DCSG00108246)
-Mismatch between subsystem id in NVDATA and SBR for 9405-W 16i.(DCSG00077700)
-BST: Num Slots config file update for topology with Atlas Configuration.(DCSG00312633)
-Release Automation: Exceptions during execution of release script.(DCSG00151389)
-Aero A0: External cards do not support more than one PCIe drives.(DCSG00249770)
-[SPDM] SPDM lib changed one of header file name , seeing compilation error in IT.(DCSG00077919)
-IT SPDM commands not working via host interface.(DCSG00134673)
-PCIe Switch Page 250 has NumPorts set to zero, and this page is not included in "iop show cfg all".(DCSG00101756)
-Disable CoreDump when Flash device is not present.(Disable CoreDump when Flash device is not present)
-MBEDTLS LIB: Add change to SConstruct to copy library output file (*.a) to release folder.(DCSG00117834)
-Coverity Defects in SATA and VPP code.(DCSG00234415)
-MFG Page 49/50/51 defines are not compiled.(DCSG00083748)
-MBEDTLS Lib: Alignment issues while certificate verification on IT cards.(DCSG00312818)
-Build failed after MbedTLS new base line pulled.(DCSG00074952)
-Aero: PswSbr.bin file is read only and causes an error when running the RMC script.(DCSG00082963)
-SBLIB: Significantly longer boot times that previously encountered in MR CBB.(DCSG00299427)
-BST: Encl_logical_id update.(DCSG00298990)
-pl: port enable is delayed when SAS/SATA devices are attached to a UBM backplane.(DCSG00076783)
-Observed PL Fault 0xEE17 when NVME drives connected via PCIe switch.(DCSG00108281)
-[MBEDTLS] Device Key Pair Generation resulting in different Keys on IT card.(DCSG00318909)
-SPDM_LIB: Set tagOwner as per SPDM request.(DCSG00239464)
-PL: SMP Timeouts During Expander Phy Reset Test.(DCSG00043616)
-[Aero] SATA drive gets dropped when corresponding phy is disabled and enabled.(DCSG00222544)
-PL: Adjust the MPI Device support check to only support Atlas's MPI Device.(DCSG00040939)
-Out of bound memory access when assigning dma group for controller devices.(DCSG00243152)
-Fail to read Extended Expander Page 250.(DCSG00092804)
-pl: NVMe: 265D fault in out of resource case.(DCSG00093410)
-SPDM_IT_FW:For empty slots IsEmpty field is shown as No it should be shown as Yes .(DCSG00230707)
-Phase 15 Coverity Bug Fixes.(DCSG00105045)
-[BST] Remove the erase persistent test case from BST.(DCSG00305439)
-(MS SES) Non data transfer SCSI IO failed with Invalid SGL error.(DCSG00234926)
-Duplicate MPI Toolbox Tool Values in MPI temp.(DCSG00086898)
-Invalid Completion code Error for running script-LearnComponentStateInvalidTransferFlagPLDMType5.py.(DCSG00149690)
-Some of SAS/SATA drives attached to OEM Aero HBA may not be reported to host.(DCSG00076717)
-Phase 15 Coverity Bug Fixes.(DCSG00092935)
-pl: firmware hang occurs in UBM command error case.(DCSG00072841)
-Connector Name displayed as 'Unknown' in HII for NVMe drives behind Switch.(DCSG00085845)
-Coverity defect fix in FPE code.(DCSG00235474)
-Fix SPDM library for Get_Digest, Challenge.(DCSG00053409)
-0x6001 Fault while running IOs and cable pull test.(DCSG00040422)
-Resetting the event counters in Ext. SAS/PCIe IO Unit Page 250 fails.(DCSG00150901)
-Update the SPDM print index properly before adding the prints to ring buffer.(DCSG00335886)
-[SPDM] Fix compilation #include "iopPlatSecCertMgMt.h" case sensitive issue.(DCSG00109315)
-NVMe device not discovered after disable-enable PCIe link in PCIe IO Unit page 1.(DCSG00082524)
-SPDMLIB: Reduce number of arguments passed to IT FW debug print functions.(DCSG00335615)
-IOP: Trace buffer image has extra "CFG string.(DCSG00051124)
-Update NVDATA Major Version on PH16 point release.(DCSG00309322)
-BST: ELID update due to SAS-Address update on Blr Servers.(DCSG00301666)
-(SATA Only) SCSI ATA Passthrough command with set feature command to set the drive in standby_y state sets it to standby_z state.(DCSG00080256)
-Release Automation: Web page button not detected in script.(DCSG00137712)
-pl: NVMe: D062 fault during NVMe init.(DCSG00083594)
-Check in SpdmDebug.h for IT.(DCSG00074108)
-Updated CoreDump specific functions to run from OCM memory and enabled XMEMXOPY.(DCSG00093703)
-Controller fault 0x1902 is seen while issuing locate command to NVMe drives.(DCSG00062252)
-PLDM RDE - MultipartReceive command fails with error INVALID_DATA for non-zero OperationID.(DCSG00165437)
-Fixing Coverity issues.(DCSG00096489)
-pl: NVMe: E429 fault on register read failure.(DCSG00098345)
-SBLIB: Change bool type to int type in API parameter to maintain compatibility.(DCSG00100308)
-SBLIB: Getting Inconsistent secure ID on IT cards.(DCSG00309847)
-BST: Aero with Atlas switch Num slot update.(DCSG00284255)
-Skip completeflash images during BST.(DCSG00337918)
-SPDM library to remove %s for any print as IT does not support %s print string.(DCSG00061353)
-"Add enclosure event for an enclosure that is already active" error message observed in Windows event logs.(DCSG00063929)
-Import certificate command with out seal option is failing for slots 0 & 1.(DCSG00228127)
-SPDM LIB: Need to include header file SpdmLibTypes.h in SpdmLibIFace.h.(DCSG00074328)
-iop show cfgspace doesn't work.(DCSG00066110)
-[Aero/Ventura] MCTP discovery fails after unload and load of MCTP driver in BMC(Board Management controller).(DCSG00058897)
-ventura build issue with PL PCI DEVICE feature disabled.(DCSG00286358)
-When performed export csr for all 8 slots in batch observing for few slot command is success and for other it is failure.(DCSG00421812)
-During OS reboot some drives go missing..(DCSG00354770)
-Remove LogSpecific member in the structure 'IOPI_LOG_DETAIL.(DCSG00318366)
-PL: Removal of NVMe Drive that Failed NVMe Init Doesn't Work Correctly.(DCSG00103998)
-Bug Fix In get CERT and While reading the certificate from the client.(DCSG00047643)
-ED91 Fault while running IOs + OCR (controller reset) testing.(DCSG00057254)
-Aero Seeing "SpdmReadCertForSlot[277]:[Error] Certificate Read Failed" on IT card after Controller Resets.(DCSG00253315)
-Coverity Defects.(DCSG00094727)
-The first 32 characters of MPI defines should be unique.(DCSG00086266)
-PH15 Scrutiny CLI: device c command output is not giving the details of the all the devices connected to the expander.(DCSG00102332)
-print correct variable during error condition.(DCSG00096538)
-MAC verification failed due to inconsistent secure ID.(DCSG00309854 (Port Of Defect DCSG00309857))
-pl: backend PCIe: 'pl pci devlnk' is missing from the 'pl dbg' dump.(DCSG00052268 (Port Of Defect DCSG00052348))
-PL: Initial MPI driver error injection can cause the Managed Switch's SES to not be exposed to OS.(DCSG00045593 (Port Of Defect DCSG00045725))
-NVMe devices VPD page 83 NAA descriptor may conflict with EUI64 ID reported.(DCSG00148775 (Port Of Defect DCSG00153702))
-Remove LogSpecific member in the structure 'IOPI_LOG_DETAIL.(DCSG00318366 (Port Of Defect DCSG00318944))
-Ventura; Add code to prevent downgrade from phase 14 to previous phases for winbond.(DCSG00059594 (Port Of Defect DCSG00061399))
-Aero: pl: SATA device may not link up following a link down.(DCSG00054906 (Port Of Defect DCSG00073959)
-"iop show cfg all" command captured by core-dump is zero.(DCSG00047928 (Port Of Defect DCSG00050673)
-PL: Blind retries by MegaRAID FW when PL is in out of resource condition results in IOs to MS-SES exhausting retries.(DCSG00033753 (Port Of Defect DCSG00046628))
-pl: backend PCIe: switch rediscovery fails with certain switch configurations.(DCSG00061635 (Port Of Defect DCSG00062706))
-PL NVMe : NVMe repair operation fails with metadata.(DCSG00112303 (Port Of Defect DCSG00121425))
-VSES SES Page 02h reports Unknown (06h) Element Status for some Array device elements in a wide DFC slot.(DCSG00069091 (Port Of Defect DCSG00086818))
-UBM: Incorrect slot number enumerated for a DFC on 3 x4 DFCs UBM config.(DCSG00048027 (Port Of Defect DCSG00048742))
-SATA only : Controller hang is observed due to recursive function call.(DCSG00139294 (Port Of Defect DCSG00226371))
-SPDMIT: Return appropriate error to SPDM Lib when read certificate from security page 0 fails.(DCSG00299079 (Port Of Defect DCSG00306949))
-pl: NVMe: unexpected NVMe init failure if LBA 0 is inaccessible.(DCSG00120588 (Port Of Defect DCSG00121315))
-PL NVMe : PCI task management is not getting completed.(DCSG00231422 (Port Of Defect DCSG00245538))
-pl: NVMe: incorrect sense key is returned for Access Denied NVMe status.(DCSG00063924 (Port Of Defect DCSG00069167))
-Ventura: The host PCIe link width may be narrower than expected.(DCSG00078678 (Port Of Defect DCSG00093473))
-Ventura/Mercator: pl: direct attached SAS or SATA device may not be discovered.(DCSG00408109 (Port Of Defect DCSG00427398))
-Some of the drives not listed under Widows OS Disk Management.(DCSG00096508 (Port Of Defect DCSG00102661)
-PL SATA: Sanitize operation is completed before actual completion from drive.(DCSG00119155 (Port Of Defect DCSG00126831))
-pl: NVMe: Select field used during NVMe init without verifying support.(DCSG00050182 (Port Of Defect DCSG00051206))
-Incorrect slot mapping on UBM backplane with additional DFCs support.(DCSG00077969 (Port Of Defect DCSG00082256))
-LED Blink/Unblink operation fails on certain Slots in UBM using MPI SEP Request.(DCSG00282826 (Port Of Defect DCSG00299898))
-Aero A0: External cards do not support PCIe and SRIS by default.(DCSG00131571 (Port Of Defect DCSG00143420))
-pl: NVMe: Drive Firmware update fails on mode 0xE.(DCSG00044028 (Port Of Defect DCSG00052008))
-Back out changes of ER DCSG00029633 that limits VSES devices to 2.(DCSG00053379 (Port Of Defect DCSG00054368))
-[SATA Only] SCSI Start Stop Unit command with power condition active fails.(DCSG00349970 (Port Of Defect DCSG00405776))
-Atlas Behind Aero: PL Fault 0xEC1A When Performing Backend PCI Resets From Diagnostic Code.(DCSG00042688 (Port Of Defect DCSG00147003))
-BSOD when running CoreDump with Aero connected to Atlas switch.(DCSG00042497 (Port Of Defect DCSG00044353))
-Invalidate slot not working for IT SPDM.(DCSG00131485 (Port Of Defect DCSG00139744))
-Drive Discovery failed with Port Hot-swap on Aero16e controller.(DCSG00042446 (Port Of Defect DCSG00052013))
-Fail to read device and link related counters from Page 250.(DCSG00080856 (Port Of Defect DCSG00096620))
-[Aero/Ventura] Bootloader corruption with firmware download and DC cycle in loop.(DCSG00238233 (Port Of Defect DCSG00245453))
-Aero: Firmware Download should return success with loginfo indicating POR is necessary.(DCSG00055371 (Port Of Defect DCSG00065882))
-PL: Over 250+ power cycles of managed switch (Atlas) causes an associated SES to be inaccessible.(DCSG00048699 (Port Of Defect DCSG00059743))
-ParentDevHandle value calculated for given Phy Number is incorrect for Direct Attached Devices in Event Replay logic.(DCSG00299632 (Port Of Defect DCSG00299897))
-[Aero][PLDM] FW version reported wrongly to BMC( Board Management Controller) over out of band.(DCSG00050201 (Port Of Defect DCSG00051130))
-[Aero/Ventura] Unused phys are managed by VSes in SGPIO BP mode.(DCSG00151021 (Port Of Defect DCSG00225221))
-VSES page 02h reports incorrect status for linkup failed array device element on certain UBM slots.(DCSG00112320 (Port Of Defect DCSG00127720))
-Ventura B0: Device discovery fails on 9400-16e.(DCSG00045385 (Port Of Defect DCSG00045779))
-PL : 0x7008 fault seen when booting the bad clocked controller connected to Atlas.(DCSG00114774 (Port Of Defect DCSG00121424))
-Drives connected behind external card with VSES disabled, failed to detect in Linux OS.(DCSG00350402 (Port Of Defect DCSG00363781))
-Aero: backend PCIe: link failure after PCIe IO Unit Page 1 link disable.(DCSG00050164 (Port Of Defect DCSG00051710))
-Expander attached devices not reported to host if enclosure slot ordering is enabled in event replay.(DCSG00108094 (Port Of Defect DCSG00111584))
-pl: NVMe: EC0E fault after drive pull during NVMe init.(DCSG00114179 (Port Of Defect DCSG00127917))
-PL: 2 Atlases in single MPT mode with 2 host ports each will have drives on one switch not mapped to that Atlas's SES Page 0Ah.(DCSG00054949 (Port Of Defect DCSG00062379))
-0xD101 Fault observed running non-RW IOs to NVMe devices with drive push-pull.(DCSG00062701 (Port Of Defect DCSG00071043))
-PH14 Windows Driver: on 2016,19H2 OS,Getting BSOD for fault command.(DCSG00048607 (Port Of Defect DCSG00053744))
-Upto 90% performance drop with expander attached configuration.(DCSG00153860 (Port Of Defect DCSG00215210))
-ExtManPage41 TX Values are not being applied / run by AERO SERDES.(DCSG00311524 (Port Of Defect DCSG00313276))
-[NVMe] SCSI log sense command timeouts seen while running 1MB IOs to NVMe drive.(DCSG00136092 (Port Of Defect DCSG00243680))
-PL: PCIe switch discovery can cause processor exception when setting enclosure information.(DCSG00063530 (Port Of Defect DCSG00063552))
-PL backend PCIe: PL fault 0xD308 is observed with Aero and Atlas connected in bad clock environment.(DCSG00134207 (Port Of Defect DCSG00137697))
-Aero: backend PCIe: link failure following link down.(DCSG00043821 (Port Of Defect DCSG00048732))
-MCTP: SenseData not available for a failed command sent over OOB.(DCSG00054655 (Port Of Defect DCSG00057485))
-Number of initiators gets decremented to 0xFF.(DCSG00051990 (Port Of Defect DCSG00053834))
-Quotes present in NVDATA XMLs.(DCSG00045528 (Port Of Defect DCSG00045606))
-Incorrect Man page 7 Phy-Slot mapping set for 9500-xx channel HBAs.(DCSG00061349 (Port Of Defect DCSG00062359))
-[Aero] Change the Manpage 7 Phy to Connector settings and Disable NVMe support in ManPage9.(DCSG00031186 (Port Of Defect DCSG00044352))
-[SPDM IT] Return actual size of certificate chain content to SPDM LIB.(DCSG00233805 (Port Of Defect DCSG00245634))
-PL SATA only : SATA init timeout observed due to drive taking longer to respond to sanitize status ext.(DCSG00225935 (Port Of Defect DCSG00227376))
-IOC Exceptions not getting cleared after flashing the BIOS image with correct ROP version.(DCSG00226395 (Port Of Defect DCSG00227987))
-AXI access errors causing FW asserts or faults due to invalid SATA passthrough commands.(DCSG00215338 (Port Of Defect DCSG00243095))
-(SATA Only) SCSI ATA Passthrough command with data transfer fails.(DCSG00120976 (Port Of Defect DCSG00121420))
-Locate PD fail on SGPIO enclosure when GroupId is disabled in Nvdata.(DCSG00034489 (Port Of Defect DCSG00041403))
-Fault 0x6109 while running IOs and device remove test.(DCSG00082201 (Port Of Defect DCSG00083887))
-PL : Missing drives during AC power cycle test.(DCSG00275868 (Port Of Defect DCSG00301822))
-NVMe Init Error List has drive entry missing when multiple Bad PDs are inserted.(DCSG00113697 (Port Of Defect DCSG00121316))
-[Aero/Ventura]Allow the backplane detection state machine to retry the FRU detection.(DCSG00219908 (Port Of Defect DCSG00222984))
-(SATA Only) MODE SELECT (6|10) to SATA drive with DEXCPT set fails if DEXCPT is already set.(DCSG00131574 (Port Of Defect DCSG00134494))
-Toolbox clean command sent to clean flash fails.(DCSG00059302 (Port Of Defect DCSG00062455))
-[VSes] SCSI State not correctly set for some error response to SCSI commands.(DCSG00312554 (Port Of Defect DCSG00324764))
-PL: TM Device Reset to NVMe drive under out of LMID condition can cause Data Abort Exception to the processor.(DCSG00036763 (Port Of Defect DCSG00048676))
-Index out of range is observed for print in ring buffer logs.(DCSG00134669 (Port Of Defect DCSG00139071))
-Aero_scrutinycli: "Device -c" command output is not matching with the firmware cli parameter values in Aero behind atlas configuration.(DCSG00121852 (Port Of Defect DCSG00127910))
-PL Fault 0000e40e while booting OS with bad NVMe drive.(DCSG00109053 (Port Of Defect DCSG00118379))
-NVMe devices VPD page 83 NAA descriptor may conflict with EUI64 ID reported.(DCSG00060347 (Port Of Defect DCSG00136105))
-Moving Controller From Single VSES config to a multi-VSES config causes issues in windows OS.(DCSG00071784 (Port Of Defect DCSG00080399))
-[VSes] Element status set to 'Unknown' in SES page 2 of VSES for some phys where nothing is connected.(DCSG00333163 (Port Of Defect DCSG00343847))
-PL NVMe : PCI task management is not getting completed.(DCSG00231422 (Port Of Defect DCSG00266052))
-Fix ring buffer decoder's slowness with decoding a trace buffer.(DCSG00050675 (Port Of Defect DCSG00051120))
-NVMe repair command fails with 'No drive support for recovery' loginfo.(DCSG00129498 (Port Of Defect DCSG00137668))
-NVMe drives not discovered and Event replay in enclosure slot mapping not working as expected.(DCSG00078212 (Port Of Defect DCSG00080846))
-As part of the Device Add\Removal Event, the enclosure handle passed on by the PL FW to the upper layer is incorrect.(DCSG00298128 (Port Of Defect DCSG00299896))
-[Aero] Fault 0xA03 observed when updating FW with a bad NVMe drive in the topology.(DCSG00132639 (Port Of Defect DCSG00136250))
-pl: NVMe: chain to PRP SGL for non-read/write IO may be handled improperly.(DCSG00408313 (Port Of Defect DCSG00427399))
-scattered file changes to include some debug prints and also minor change to debug print.(DCSG00057124 (Port Of Defect DCSG00057818))
-Firmware asserts during customer specific UBM Backplane enumeration.(Firmware asserts during customer specific UBM Backplane enumeration.)
-[Aero][AutoPort Enable] Erase persistent config pages is not retaining the VPD and sas address.(DCSG00074378 (Port Of Defect DCSG00114250))
-Import certificate command is failing via In-band.(DCSG00212544 (Port Of Defect DCSG00215132))
-[Aero][PLDM] Update to Latest PLDM library v13.(DCSG00137629 (Port Of Defect DCSG00138016))
-AXI access error from TxDMA engine when certain errors occur during Task Management processing.(DCSG00078508 (Port Of Defect DCSG00235435))
-SPDM IT:SPDM BMC bring up on P2 server.(DCSG00238540 (Port Of Defect DCSG00241397))
-SATA Only: Command timeout observerd on SATA drives.(DCSG00344039 (Port Of Defect DCSG00356005))
-Aero: PL with newer Atlas FW (4.2) has extra slot number in the Atlas enclosure.(DCSG00284238 (Port Of Defect DCSG00291431))
-Aero A0: In Windows OS redundant disks detected when controller connected to Elrond Ex1.(DCSG00061406 (Port Of Defect DCSG00065448))

EnhancementRequests:
-Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG.(DCSG00105430)
-PL: Support Managed Switch (Atlas) slot range VSEC command for its single MPT mode.(DCSG00071626)
-NVMe Drive Init failure Error Reporting.(DCSG00055566)
-MBEDTLS LIB: Change large local variable memory allocation from the stack to dynamic memory allocation from the heap.(DCSG00087564)
-Aero/Ventura: Move DMCore hardware file to common.(DCSG00007511)
-SEA IT TRNG HW enable.(DCSG00098752)
-Add Avenger support for libmbed tls.(DCSG00051695)
-Bring up OEM Specific BST Server.(DCSG00325843)
-pl: NVMe: handle Namespace Not Ready error during NVMe init (part 2).(DCSG00075871)
-Implement event message supported, event message buffer size and platform event message for PLDM type 2 - monitoring and control app.(DCSG00149551)
-Enable 24 NVMe drive support by default for external controllers.(DCSG00305223)
-Health Data Events - Create counters for various Health Data Events(DCSG00078912)
-Resolving the compilation conflicts while integrating the library with FW.(DCSG00045470)
-PLDM - Add Linked List Traverse utility and correct TID API function.(DCSG00165389)
-UpdateVersion tool to change and update version information in ClearCase.(DCSG00072590)
-Implemented change to use FTP instead of UNC for upload / download of unsigned / signed artifacts to workaround firewall issue.(DCSG00129388)
-Ventura/Aero: Add Ext. Man Page 48 to store CoreDump options.(DCSG00026309)
-[Aero][SPDM] IOP framework to support CFGI Reads and Writes.(DCSG00076512)
-Add Aero/Sea Info to Ventura Summary Release Notes.(DCSG00077941)
-[SPDM]SBlib upgrade to 2.02.(DCSG00091314)
-Provide Configurability For SPDM Library.(DCSG00045604)
-BST: Add support for Drive Control Modules to cable breaker test cases.(DCSG00256443)
-Aero3: SecureBoot BIOS Image Download with new Key is failing.(DCSG00233694)
-Platform related configuration changes updation.(DCSG00039844)
-MBEDTLS LIB: Implementation: Use CDI to generate ECDSA key pair.(DCSG00067411)
-[BST] Add the corrective action in BST scripts to check if SAS address is retained after persistent erase.(DCSG00216341)
-Port secureSignBin.exe for MARGAY signing to GCP server environment.(DCSG00040377)
-Update HWBIC Generation XMLs for CQ9.(DCSG00100142)
-SPDMLIB: OEM requested to not report Get Measurement Capable.(DCSG00323053)
-BST: Verify version control file from fw.(DCSG00268618)
-Release Automation: Submit auto-BST jobs.(DCSG00091315)
-SPDM_LIB: Support to build Challenge buffer with multiple GET_CERTIFICATE/CERTIFICATE_RESPONSE.(DCSG00225175)
-Resolving the compilation conflicts while integrating the library with FW.(DCSG00045448)
-Update Version descriptors for standard inquiry data of SATA and vSES devices.(DCSG00037325)
-Certificate read and Write wrapper functions & Slot management.(DCSG00105005)
-[Aero SPDM] XSD changes to support SPDM version in a new manufacturing page.(DCSG00103227)
-Automate Build Job and Release Job Submission Process.(DCSG00045139)
-Update NVMe to SCSI Error code translation.(DCSG00098339)
-Remove A0 raw fw rawA0.fw file from release scripts.(DCSG00211914)
-Added "pl serdes tx" and "pl serdes rx" command.(DCSG00053828)
-Support for NVMe Firmware Download when the image size exceeds the SNTL Transfer limitation.(DCSG00053656)
-BST: A test to verify slot counts.(DCSG00238332)
-MPI changes to configure backend ASPM.(DCSG00051277)
-Shrink MbedTLS library size.(DCSG00059001)
-MBEDTLS LIB: Parse certificate to X.509 V3 Standard and verify digital signature to affirm chain of trust.(DCSG00216867)
-Avenger support for the LIBSPDM.(DCSG00081168)
-UBM BST: Ensure UBM BP details reported by FW are accurate.(DCSG00227823)
-Add IT+Expander controller to OEM BST server.(DCSG00286591)
-pl: SATA: vendor specific ATA Standby handling.(DCSG00074400)
-Log 0 SPDM events for certificate slot & key management.(DCSG00322202)
-Aero/Ventura: Enable easier debug when SPI FLASH is bad.(DCSG00058537)
-PLDM Type 2 - Implement support for dynamic PDR repository change.(DCSG00165393)
-Support MPB2 write/read into manufacturing region.(DCSG00063677)
-Log SPDM events entries in log page 0.(DCSG00139949)
-PL: NVMe Drive Repair.(DCSG00055563)
-Implement a secure version of memset for SPDM code to use to zero out buffer.(DCSG00208365)
-Automate version update stage in release process.(DCSG00122144)
-Fix Mbedtls build scripts to accommodate Aero and Avenger.(DCSG00150272)
-SPDM LIB: Implement version scheme.(DCSG00072483)
-Aero multi-party signing partial signing of images.(Aero multi-party signing partial signing of images)
-Correcting the print function configuration.(DCSG00047741)
-XSD and NVDATA changes to support SPDM manufacturing and Security pages.(DCSG00063680)
-PL logic to create VSES instances per Backplane number.(DCSG00069245)
-SECUREBOOT_LIB: Move SRK and CCR eFuse register access functions to SBLIB.(DCSG00086765)
-SPDM_LIBRARY: Change for SPDM Policy Implementation.(DCSG00097417)
-Package Stamping Verification.(DCSG00096506)
-[Aero][Ventura] Sign windows build applications and avoid antivirus from deleting them.(DCSG00025757)
-Allow General Processing Failure from Atlas on unsupported commands to not result in 0xEA20 fault.(DCSG00170698)
-Implement customSign.exe CLI wrapper utility to help customers sign with their private key.(DCSG00234646)
-Release Automation: Integrate utility for deliver/rebase into release scripts.(DCSG00094677)
-Added SPDM lib to IT FW code base and handle MCTP VDM SPDM commands.(DCSG00063688)
-Config file changes to including prints.(DCSG00047716)
-MBEDTLS LIB: Enhancement to source of randomness for generating key pair.(DCSG00148786)
-pl: backend PCIe: add debug print for a discovery failure case.(DCSG00083082)
-Implement support for Cross certificate and command - Windows signing using CNG Provider with HSM Protected Key.(DCSG00030211)
-Release Automation: updates for rebase operation.(DCSG00134475)
-[Aero] [SPDM] Support Export Certificate Signing Request command.(DCSG00063692)
-Ventura/Aero: Update SPI flash test to print better failure information.(DCSG00070917)
-Remove cdi get for Avenger.(DCSG00152679)
-MbedTLS lib integration with IT FW.(DCSG00063687)
-MBEDTLS: Implementation: Implement Subject Name validation for CSR (Certfificate Signing Request) and CSR generation.(DCSG00069942)
-Release Automation: Integration of all script modules.(DCSG00120937)
-Signing Linux executables via GPG method in HSM.(DCSG00077215)
-PL: Coordinate reset on Atlas FW update to limit IO disruption to NVMe drives behind Atlas.(DCSG00097342)
-Implemented secureSignCNG.exe CLI signing tool for Windows Signing.(DCSG00023491)
-MbedTLS: Explicitly make enumerator value of enum type to 4-byte value.(DCSG00054557)
-Providing Link and Device Related Counters.(DCSG00056834)
-MBEDTLS LIB: Rename sha256.h header file to avoid conflict with MR FW sha256.h header file.(DCSG00068675)
-Enable 24 PCIe device support for Aero External boards.(DCSG00278073)
-Aero3: Harden Managed Switch SES (Atlas) SES Page 0Ah translation with error injection framework.(DCSG00037053)
-Release Automation: Automate state transitions for ReleaseOrder.(DCSG00035457)
-ComboSerdes: add functionality for bypass ready waiting.(DCSG00167482)
-Aero SPDM Sblib change: provide sblib interface to disable specified HW debug port.(DCSG00166877)
-MBEDTLS LIB: Implement version scheme.(DCSG00072481)
-Aero: Change XMEMCOPY default to disabled in Aero.(DCSG00082841)
-SPDM library: Adding PLDM print module style.(DCSG00060323)
-Release Automation: Validate FW Header post Package Creation.(DCSG00055071)
-CM Utility to perform automated Deliver and Rebase actions.(DCSG00083856)
-PL UBM support UBM for PCIe SW upstream port config.(DCSG00120726)
-Release Automation: create Aero IT FW only Release Order Package.(DCSG00066845)
-SPDM LIB: Implement SPDM Get Measurement command.(DCSG00234758)
-CFGI: support build persistent config region from MPB2.(DCSG00077614)
-Disable hardware debug ports.(DCSG00143569)
-pl: backend PCIe: PCIe Hinting.(DCSG00050640)
-BST: Config update with Blr servers data for slot count.(DCSG00248916)
-Aero/Ventura: Add CLI to test QE bit modification.(DCSG00148653)
-Add SasSerdesCtl0_7 registers to pl serdes.(DCSG00069982)
-pl: NVMe: handle Namespace Not Ready error during NVMe init.(DCSG00071652)
-MbedTLS Lib: disable file system related functions & enable memory allocation and prints functions to be compiled in CPP environment.(DCSG00060384)
-CFGI support for write/read into manufacturing region MPB2.(DCSG00065597)
-CDI & Key Generation source integration with IT FW.(DCSG00063690)
-pl: NVMe: update Block Limits VPD page translation.(DCSG00055387)
-Add support for C++/CPP compile for libspdm.(DCSG00051200)
-[Aero IT SPDM] Attestation policy at the boot-up time.(DCSG00063691)
-Update PLI Spec.(DCSG00008045)
-Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847)
-pl: backend PCIe: examine BAR attributes following endpoint/switch reset.(DCSG00060688)
-UCM Action tool feature to support rebase using latest baseline.(DCSG00125616)
-Update Sea Channel XMLs to PCI Device ID 0xE6.(DCSG00079238)
-SECUREBOOT_LIB: Move hardware touch (ApSha HASH & HMAC and OTP eFuse Read) from MR SPDM code to Secure Boot Lib.(DCSG00082166)
-[IT SPDM] Parse certificate to X.509 V3 Standard and verify digital signature to affirm chain of trust.(DCSG00218564 (Port Of EnhancementRequest DCSG00322020))
-Aero Secure Boot: Add Key Update Pending Check for 'COMPLETE' Image Download.(DCSG00241566 (Port Of EnhancementRequest DCSG00250024))
-Advertise certain Secure Boot Properties using a config page for Application to be able to display it.(DCSG00078835 (Port Of EnhancementRequest DCSG00093843))
-Enhancement to source of randomness for generating key pair.(DCSG00208477 (Port Of EnhancementRequest DCSG00250093))
-[IT SPDM] Implement client APIs for SPDM Get Measurement command..(DCSG00256411 (Port Of EnhancementRequest DCSG00293435)
-Aero SAS Performance Enhancement on AMD Rome as part of PR.(DCSG00064583 (Port Of EnhancementRequest DCSG00065934))
-SPDM IT: Add memory allocation/free for SPDM_LIB.(DCSG00229260 (Port Of EnhancementRequest DCSG00241396))
-Modify Ventura Build scripts to add a new Signed image with different AVSO Setting in FW RO.(DCSG00231216 (Port Of EnhancementRequest DCSG00231535))
-[SPDM IT] Export CSR & Import Cert Open & Close Session.(DCSG00221406 (Port Of EnhancementRequest DCSG00257575))
-Update the event logging when the "CoreDump" region is erased from ScrutinyCLI command.(DCSG00367325 (Port Of EnhancementRequest DCSG00418780))


Version  14.05.00.00
--------------------
   BIOS            Firmware      UEFI Driver   
 9.27.00.00     14.00.10.00    14.00.05.00
Ph_13
Defects:
-Response of TransferComplete (0x16) become irrelevant if it is received after the successful completion of CancelUpdateComponent(0x1C)and needs to be dropped.(DCSG00033524)
-Ventura B0: Device discovery fails on 9400-16e.(DCSG00045385)
-CFGI: CFGI is including printf.(DCSG00027583)
-PLDM Type 6: Incorrect error code returned for resource unregistration.(DCSG00067924)
-Increase the number of Fast Training Sequences requested by Aero. (PL).(DCSG00031501)
-Ventura B0: 4 enclosures are created for 2 vSES in multi-UBM config in x8 mode.(DCSG00035111)
-BST: BST cancellations on cable breaker comm port unavailability.(DCSG00212793)
-pl: backend PCIe: debug prints.(DCSG00013387)
-pl: backend PCIe: switch rediscovery fails with certain switch configurations.(DCSG00061635)
-PLDM Type6 : Change filename for fixing doxygen compilation.(DCSG00081863)
-PLDM Type5 : Controller FW Downgrade through BMC results in controller FW crash.(DCSG00095783)
-PL: Remove the using of an LMID frame as a request or reply frame to an MPI Device.(DCSG00040943)
-Atlas behind Aero IT: Fault code: 0x4000EDAC while running IOs and TMs..(DCSG00022533)
-Ventura B0: PCIe support disabled with UBM and Capella II switch in the topology.(DCSG00039024)
-PL: Over 250+ power cycles of managed switch (Atlas) causes an associated SES to be inaccessible.(DCSG00048699)
-SPILIB: New Version of Winbond SPI flash times out on write.(DCSG00054923)
-pl: NVMe: CFS not checked during handling of Abort Task.(DCSG00023749)
-Ventura B0: ISTWI Error observed during controller cable management initialization.(DCSG00041605)
-BST: UBM BST funtonality is broken on latest BST code..(DCSG00216461)
-Aero: PL cannot handle very large SES Page 0Ah from Managed Switch SES for MPI SEP Request.(DCSG00010049)
-pl: backend PCIe: 265D fault after deferred max payload size configuration.(DCSG00036696)
-Aero A0: In Windows OS redundant disks detected when controller connected to Elrond Ex1.(DCSG00061406)
-PLDM Type-2 : GetPDRRepository command fails with large configuration (mulitple drives and volumes).(DCSG00097462)
-BSOD when running CoreDump with Aero connected to Atlas switch.(DCSG00042497)
-NVDATA Major version should be 0E00 for Phase 14.(DCSG00022006)
-BST: Case mismatch in card name.(DCSG00114314)
-Backend PCIe link cfg may fail attaching to Ux2 UBM backplane.(DCSG00037821)
-9500 Channel board default I2C clock frequency higher than the spec specified.(DCSG00039829)
-Do not process any response msg if FD is in PLDM_FW_UPDT_IDLE state..(DCSG00024158)
-Avenger IOP: When CBB replies to NVSRAM Init PMU message, it returns FALSE.(DCSG00017760)
-Application cannot find the CoreDump region size needed to erase the region.(DCSG00028503)
-Incorrect slot mapping on UBM backplane with additional DFCs support.(DCSG00077969)
-PL: 2 Atlases in single MPT mode with 2 host ports each will have drives on one switch not mapped to that Atlas's SES Page 0Ah.(DCSG00054949)
-Updating FW (on 9400 series HBA) from Ph-7 to Ph-14 causes "invalid flash" message on FW bootup.(DCSG00167100)
-BST: SAL reports unknown device type for drives.(DCSG00239268)
-Aero: Error on posting a SCSI IO request to Atlas SES can cause IO forever being pended.(DCSG00012605)
-Aero: backend PCIe: 265D fault if PCIe Device Page 2 is read for a SES device.(DCSG00016069)
-Windows powershell shows 48 slots in single VSES mode.(DCSG00022999)
-Toolbox clean command sent to clean flash fails..(DCSG00059302)
-[Aero/Ventura]Allow the backplane detection state machine to retry the FRU detection..(DCSG00219908)
-Updated GoldenX to handle the CoreDump Region.(DCSG00042890)
-"iop show diag" output collection in CoreDump causes controller to hang.(DCSG00027941)
-pl: backend PCIe: Atlas switch may not be discovered.(DCSG00036613)
-Aero: backend PCIe: link failure after PCIe IO Unit Page 1 link disable.(DCSG00050164)
-pl: NVMe: maximum blocksize should be limited to 2 MB.(DCSG00022705)
-[Aero][PLDM] Update to Latest PLDM library v13.(DCSG00137629)
-PL: Controller not functional when booting up with 2 Ex1 UBMs in x8 mode.(DCSG00038959)
-BST: POR Reboot requires a further check.(DCSG00086783)
-Aero3: In XMEMCOPY==0 mode writes to config pages get overwritten on next reset.(DCSG00038206)
-[Aero/Ventura] Bootloader corruption with firmware download and DC cycle in loop..(DCSG00238233)
-"iop show cfg all" command captured by core-dump is zero.(DCSG00047928)
-PL: Back-to-back retries by IOP/Host when PL is in out of resource condition results in IOs to MS-SES exhausting retries.(DCSG00033753)
-[Aero][PLDM] FW version reported wrongly to BMC( Board Management Controller) over out of band.(DCSG00050201)
-PLDM Lib: Unable to stop timer (PLDM Fault 0x11).(DCSG00134602)
-pl: NVMe: Write Buffer parameters should be validated against FWUG.(DCSG00027855)
-Aero: Various faults occur with PCIe clock configuration mismatch between Aero and managed switch (Atlas).(DCSG00012378)
-PLDM Type5 : Upgrade to the latest signed FW fails.(DCSG00076949)
-UBM Auto HFC grouping fixes and debug print fixes.(DCSG00012363)
-PL Discovery debug prints for Expander Phys/Encl slot enumeration.(DCSG00039850)
-PL: PCIe switch discovery can cause processor exception when setting enclosure information.(DCSG00063530)
-UBM: Incorrect slot number enumerated for a DFC on 3 x4 DFCs UBM config.(DCSG00048027)
-Number of initiators gets decremented to 0xFF.(DCSG00051990)
-pl: NVMe: controller reset shouldn't be issued if EN or RDY are 0.(DCSG00024038)
-Aero: pl: SATA device may not link up following a link down.(DCSG00054906)
-Coredump text files don't have file extensions.(DCSG00043119)
-[Aero][AutoPort Enable] Erase persistent config pages is not retaining the VPD and sas address.(DCSG00074378)
-Aero A0: Write and DC issues on NVMe drives running data integrity with XMEMCOPY==0 (new boot mode).(DCSG00034356)
-Coverity detected unreachable code in IOP MCTP code.(DCSG00010189)
-SPILIB2: If the default clock divider is specified, there are excessive clock prints.(DCSG00013239)
-PL: TM Device Reset to NVMe drive under out of LMID condition can cause Data Abort Exception to the processor.(DCSG00036763)
-BST: Board naame format error.(DCSG00143769)
-PH14 Windows Driver: on 2016,19H2 OS,Getting BSOD for fault command.(DCSG00048607)
-PLDM Type 6: BEJ buffer insertion pointer is not incremented when an element is added to array context.(DCSG00067926)
-Ventura; Add code to prevent downgrade from phase 14 to previous phases for winbond.(DCSG00059594)
-Fault 4322 Observed On Sea 8i Board.(DCSG00028298)
-Fix ring buffer decoder's slowness with decoding a trace buffer.(DCSG00050675)
-Back out changes of ER DCSG00029633 that limits VSES devices to 2.(DCSG00053379)
-Change 2WIRE_RESET and PERST GPIO signals logic level in NVDATA settings.(DCSG00025523)
-pl: NVMe: incorrect sense key is returned for Access Denied NVMe status.(DCSG00063924)
-Aero/Ventura: Fault 0xD203 - Trace Buffer Manager not in Extended mode when processing diagnostic requests..(DCSG00033003)
-RDE: Valid schema class can't be more than 4 for 'GetSchemaURI' command.(DCSG00109749)
-Some of the drives not listed under Widows OS Disk Management..(DCSG00096508)
-Allow PCIe IO Unit page 1 link rate debug override option to override BP reported max link rate.(DCSG00042965)
-BST: Uart Utility re-visit.(DCSG00113761)
-SPILIB 2.0: Custom Parts Write Parameters are Incorrect.(DCSG00018735)
-SPILIB: The SPI2 release zip contains SPI1 headers.(DCSG00019887)
-Quotes present in NVDATA XMLs.(DCSG00045528)
-PL: Remove all MPI 2.6 PCIe event handling and unexpected SAS events from managed switch's MPI Device.(DCSG00040937)
-Expander attached devices not reported to host if enclosure slot ordering is enabled in event replay..(DCSG00108094)
-PL: Firmware is incorrectly acking spinup requests twice in a row.(DCSG00031070)
-[Aero] Change the Manpage 7 Phy to Connector settings and Disable NVMe support in ManPage9.(DCSG00031186)
-SPILIB 2.0: Initialization fails for Spansion 64MB part in serial mode.(DCSG00061011)
-pl: backend PCIe: endpoint or switch is unexpectedly reset in a couple of error cases.(DCSG00030361)
-BST: Case mismatch for custom card name.(DCSG00115303)
-SPILIB2: Windbond 16MB device fails to program.(DCSG00017381)
-PL: NVMe: Remove MPI26_EVENT_PCIDEV_STAT_RC_SANITIZE_OPERATION_COMPLETED Temporary Event.(DCSG00031848)
-Increase the time wait time when quad mode bit gets written for write operation to complete.(DCSG00061711)
-[Aero] Upload request for the flash regions like CoreDump/Config1/Config2/SBR/CBB fails with LogInfo code: 0x30010416.(DCSG00034467)
-Aero: backend PCIe: link failure following link down.(DCSG00043821)
-SPILIB 2.0: Cypress 256Mbit SPI Flash Is Not Supported.(DCSG00121768)
-HW Workaround:Resizable BARs capability.(DCSG00014562)
-Firmware asserts during customer specific UBM Backplane enumeration..(DCSG00058770)
-pl: Ventura/Mercator: device side PCIe link failure following adapter reset.(DCSG00024652)
-Build error in PLDM Library on ARM 4.1 compiler with Atlas FW build environment.(DCSG00071478)
-Aero: Firmware Download should return success with loginfo indicating POR is necessary.(DCSG00055371)
-pl: NVMe: Drive Firmware update fails on mode 0xE.(DCSG00044028)
-SPILIB: Winbond 256MBit maximum page write time increased from rev "A" to rev "B" of their specification.(DCSG00170747)
-Shenandoah_Firmware_RDE: Controller information not getting launched in RDE Client.(DCSG00099613)
-Need PL MPI Device data dumps in "pl dbg" for debug, i.e. "pl mpidev dbg".(DCSG00037838)
-[Ventura] SAS/SATA direct attached drive is not listed when VSES disabled in nvata..(DCSG00033019)
-pl: backend PCIe: 'pl pci devlnk' is missing from the 'pl dbg' dump.(DCSG00052268)
-PL: Initial MPI driver error injection can cause the Managed Switch's SES to not be exposed to OS.(DCSG00045593)
-Aero: HW_SETTINGS_CHANGE PCIe PHY LF setting should be changed from 16 to 15.(DCSG00012481)
-PL: Device removal event is not sent for hot removed end device.(DCSG00023448)
-PLDM Type 6: Fix "RedACT" tool reported observations.(DCSG00080427)
-pl: NVMe: limit resource frame usage by NVMe IO breakup.(DCSG00039263
-Bug in SerDes M0 Code U16RegDataFindReplace().(DCSG00043881)
-Aero A0: Atlas switch (SRIS mode) not discovered with Elrond Ex1 config.(DCSG00036996)
-pl: port enable timeout when PCIe and backplane detection are disabled.(DCSG00035201)
-Aero: During FW download we should not overwrite status when POR is necessary.(DCSG00062988)
-PLDM Type 2: Resource associated major schema count is incremented incorrectly.(DCSG00074150)
-[PLDM] IT HBA with latest PLDM library faults.(DCSG00102618)
-Aero BST: Manage NVMe drive link up timing.(DCSG00228186)
-After executing "coredumo -erase" from ScrutinyCLI, flash offsets are not reset.(DCSG00037801)
-pl: backend PCIe: incorrect value written to Device Status/Control register during error handling.(DCSG00038289)
-Incorrect Man page 7 Phy-Slot mapping set for 9500-xx channel HBAs.(DCSG00061349)
-Unable to detect drives behind Sea controller during Windows installation.(DCSG00012569)
-pl: NVMe: Select field used during NVMe init without verifying support.(DCSG00050182)
-Aero3: Uploading main firmware in XmemCopy=0 mode causes an abort.(DCSG00035015)
-scattered file changes to include some debug prints and also minor change to debug print.(DCSG00057124)
-Some of SAS/SATA drives attached to OEM Aero HBA may not be reported to host.(DCSG00076717 (Port Of Defect DCSG00079658)
-Coverity Bugs in PL Enclosure Management Files.(DCSG00043514 (Port Of Defect DCSG00045037))
-Drive Discovery failed with Port Hot-swap on Aero16e controller.(DCSG00042446 (Port Of Defect DCSG00052012))
-PL: Fault 0xD033 During Drive Pull Testing.(DCSG00027593 (Port Of Defect DCSG00027904))
-pl: backend PCIe: resource leakage during direct attached event generation.(DCSG00093660 (Port Of Defect DCSG00096715))
-pl: NVMe: unexpected task management halt may occur.(DCSG00014455 (Port Of Defect DCSG00020914))
-Aero-3: Serdes parameters from NVDATA are not sent to Serdes.(DCSG00022778 (Port Of Defect DCSG00026085))
-Multiple VSES created on SAS only 8-Slot UBM backplane with duplicate slot assignments.(DCSG00017373 (Port Of Defect DCSG00020913))
-Backplane detection never completes leading to discovery timeout.(DCSG00023081 (Port Of Defect DCSG00027622))
-PL improperly cleaning up and recovering from hot resetting MPI Device (i.e. reinitializing MPI Device failing).(DCSG00032157 (Port Of Defect DCSG00032901))
-VSES SES Page 02h reports Unknown (06h) Element Status for some Array device elements in a wide DFC slot.(DCSG00069091 (Port Of Defect DCSG00086819))
-pl: backend PCIe: IO halt following temporary device removal.(DCSG00015943 (Port Of Defect DCSG00017372))
-pl: NVMe: fix a couple of debug issues related to unique identifiers.(DCSG00014628 (Port Of Defect DCSG00014917))
-PL : PL fault 0x7C41 is observed.(DCSG00030914 (Port Of Defect DCSG00032163))
-pl: firmware hang occurs in UBM command error case.(DCSG00072841 (Port Of Defect DCSG00072924))
-pl: backend PCIe: prevent switch rediscovery quirks.(DCSG00018730 (Port Of Defect DCSG00046563))
-Locate PD fail on SGPIO enclosure when GroupId is disabled in Nvdata..(DCSG00034489 (Port Of Defect DCSG00044448))
-Fault 0x265d seen when the UBM FRU I2C read size configured to 2 bytes..(DCSG00026985 (Port Of Defect DCSG00031183)
-Aero: Powered cycled managed switch SES can become inaccessible.(DCSG00021412 (Port Of Defect DCSG00023096))
-MCTP: SenseData not available for a failed command sent over OOB.(DCSG00054655 (Port Of Defect DCSG00057482))
-[Aero] Application scanning for I2C devices on I2C bus hang when OOB configured to MCTP-PCIe mode.(DCSG00103208 (Port Of Defect DCSG00104071))
-UBM BP product revision version mismatch b/w SES Page 01 and SCSI Inquiry output.(DCSG00036978 (Port Of Defect DCSG00039453))
-Aero/Ventura] MCTP discovery fails after unload and load of MCTP driver in BMC(Board Management controller).(DCSG00058897 (Port Of Defect DCSG00171389))
-VSES may not report valid SES Page 0Ah elements for one of quads attached elements in a UBM backplane.(DCSG00013123 (Port Of Defect DCSG00013128))
-UBM Link Config may fail for HBA connector with Phys routed spans CSWs.(DCSG00022691 (Port Of Defect DCSG00023388))
-PL 0x4E00 fault occurs when Task Management Device Resets are issued to different manged switch SESes at the same time.(DCSG00032952 (Port Of Defect DCSG00037846))
-Moving Controller From Single VSES config to a multi-VSES config causes issues in windows OS..(DCSG00071784 (Port Of Defect DCSG00082367))
-Ventura B0: vSES goes missing after the first controller reset on UBM Ex1 in x8 HFC config.(DCSG00024555 (Port Of Defect DCSG00025784))
-pl: Ventura/Mercator: device side PCIe link failure following adapter reset.(DCSG00038775 (Port Of Defect DCSG00039129))
-Controller fault 0x1902 is seen while issuing locate command to NVMe drives.(DCSG00062252 (Port Of Defect DCSG00066057)
-pl: discovery failure if PCIe backplane detection is disabled.(DCSG00013397 (Port Of Defect DCSG00014547))
-Ventura: The host PCIe link width may be narrower than expected.(DCSG00078678 (Port Of Defect DCSG00093474))
-(SATA Only) SCSI ATA Passthrough command with set feature command to set the drive in standby_y state sets it to standby_z state.(DCSG00080256 (Port Of Defect DCSG00227982))
-0xD101 Fault observed running non-RW IOs to NVMe devices with drive push-pull.(DCSG00062701 (Port Of Defect DCSG00071042))
-Aero A0: vSES is created even for managed Atlas (Ibanez) switch.(DCSG00012487 (Port Of Defect DCSG00015123)
-Aero: NVMe: device not removed if init fails and it then goes missing.(DCSG00013404 (Port Of Defect DCSG00019619)
-Scrutiny GUI clear option fails to reset the PCIe error counters.(DCSG00014510 (Port Of Defect DCSG00015318))
-pl: backend PCIe: EC5B fault.(DCSG00022805 (Port Of Defect DCSG00024022))
-ED91 Fault while running IOs + OCR (controller reset) testing.(DCSG00057254 (Port Of Defect DCSG00066123)
-"Add enclosure event for an enclosure that is already active" error message observed in Windows event logs.(DCSG00063929 (Port Of Defect DCSG00080661))
-Ventura B0: vSES not reported in Windows 2019 on certain UBM backplane config.(DCSG00026333 (Port Of Defect DCSG00026717))
-Sea 16e PCIe TX Compliance Test Failure.(DCSG00052179 (Port Of Defect DCSG00082837))
-NVMe drives not discovered and Event replay in enclosure slot mapping not working as expected..(DCSG00078212 (Port Of Defect DCSG00080844))
-pl: backend PCIe: 'pl pci dbgall' causes ring buffer spam.(DCSG00019925 (Port Of Defect DCSG00020114)
-On Locating PD's,LED's are not blinking for drives connected to customer specific SGPIO Backplane..(DCSG00018823 (Port Of Defect DCSG00025496))
-Channel SAS3.5 HBAs cannot support published PD limits when loaded with SAS/SATA-only FW image.(DCSG00020917 (Port Of Defect DCSG00025802))
-Ventura B0: Incorrect VSES associated to unmanaged PCIe SW enclosure.(DCSG00023764 (Port Of Defect DCSG00024350))
-[Aero]Remove NVMe support for SAS/SATA profile only.(DCSG00022886 (Port Of Defect DCSG00043411))
-0x6231 Fault during Sata Task Management.(DCSG00019315 (Port Of Defect DCSG00023449)
-IOP: Trace buffer image has extra "CFG string.(DCSG00051124 (Port Of Defect DCSG00051218))
-NVMe devices VPD page 83 NAA descriptor may conflict with EUI64 ID reported.(DCSG00060347 (Port Of Defect DCSG00136106))
-pl: NVMe: E425 fault after vendor specific device firmware update.(DCSG00012593 (Port Of Defect DCSG00023687))

EnhancementRequests:
-Create method to give verbose fault code descriptions.(DCSG00008046)
-Update summary release notes.(DCSG00008993)
-Ventura/Aero: Get debug file array sizes via a API variable for CFGI and PL.(DCSG00007512)
-PL support for reporting UBM Backplane Number.(DCSG00031340)
-Aero/Ventura: Add capability to return UNKNOWN status in SES, page 2, when link is down yet presence detected.(DCSG00015055)
-BST: Add Ventura activity server and enclosure to test config.(DCSG00079826)
-Enable UBM BST support for Aero.(DCSG00063407)
-Aero/Ventura: Integrate SPILIB 2.0 into IT firmware.(DCSG00010293)
-BST: Update scripts to run Customer fw on channel adapter.(DCSG00082887)
-Change Aero default UART speed to 921600.(DCSG00026455)
-Re-naming few functions in module-object-verb format.(DCSG00027061)
-Ventura: Fix OEM Page7 Data.(DCSG00014014)
-MS-SES: Enabling translating devices in SES Page 0Ah from managed switch with non-unique BDFs.(DCSG00027432)
-SPILIB: Modify Spilib 2.0 print settings to allow some prints in INFO.(DCSG00012641)
-Update CFGI Library.(DCSG00084270)
-Added documentation for some scenarios.(DCSG00027067)
-Update IOP debug prints to replace %x with an appropriate modifier.(DCSG00015603)
-Remove Obsolete Config Pages.(DCSG00020911)
-CFGI: Add variable to indicate reserved indices for debug prints.(DCSG00020866)
-Aero: Update to SECUREBOOT Librrary 2.01.00.00.(DCSG00015120)
-Aero: Unmap SPI areas that are virtually mapped to code areas.(DCSG00033552)
-pl: NVMe: RTD3 Entry Latency shutdown timing.(DCSG00014564)
-BST: Aero Activity server with Atlas switch.(DCSG00225036)
-Define Macros/inline functions.(DCSG00027051)
-Allow host utils to manage CSWs individually in the presence of UBM.(DCSG00007471)
-SPILIB2: Eliminate address mask for Avenger Compatibility.(DCSG00013352)
-SPILIB(2): SPI Library based upon API 2.0.(DCSG00009014)
-CFGI: Temporary Changes to Make CFGI compatible with SPILIB 2.0.(DCSG00012453)
-Determine UBM DFC drive type installed based on IFDET# and PRSNT# signals support implemented.(DCSG00029636)
-DCSG00030213
-PLDM: Implement PLDM Type-6 library API and commands.(DCSG00064565)
-pl: backend PCIe: check in some plugfest diag console code.(DCSG00012454)
-MPI 2.6: Add additional IOC_State (CoreDump) to allow firmware to dump debug logs without being reset by host..(DCSG00020567)
-Aero/Ventura IT: NVDATA Changes to enable FLASH execution mode.(DCSG00033543)
-PLDM library support to report multiple PLDM App versions to BMC.(DCSG00026969)
-BST: Customer specific Release/Activity BST at BLR.(DCSG00064578)
-pl: backend PCIe: add ring buffer printing of PL-initiated transaction data.(DCSG00018268)
-PLDM Type 6: Add debug strings for Type-6 library.(DCSG00065842)
-FD should move to DOWNLOAD state immediately upon successfully sending the response of UDATE_COMPONENT..(DCSG00046402)
-For new CoreDump feature, set IOC-Capabilities "CoreDump" bit based on ManPage11 value only.(DCSG00031051)
-pl: backend PCIe: modify default PCIe device missing delay setting.(DCSG00018758)
-Add support for managed switch (Atlas) WWID in Vendor Specific Extended Capability.(DCSG00007993)
-Updated CFGI Lib to remove duplicate IOP files.(DCSG00062723)
-Active State Power Management (ASPM) feature support for backend PCIe links.(DCSG00019848)
-Integrate MPI 2.6.9 headers into Ventura/Aero code.(DCSG00027926)
-Add Attention Button for drive removal support for traditional PCIe Hotplug in PCIe switches.(DCSG00017456)
-BST: Customer Aero based ROP BST and setup at BLR.(DCSG00109334)
-Define APIs for PLDM debug infrastructure and Implements debug routine for PLDM Base.(DCSG00026992)
-Automate version update stage in release process.(DCSG00035455)
-IOC FW need to capture Optical Cable's vendor serial number (vendor SN) so driver will be able to read it via MPI spec.(DCSG00023086)
-.(Aero3: Enable XmemCopy Mode.(DCSG00035867)
-Limit VSES device instances support to max 2.(DCSG00029633)
-BST: set SRIS after every fw download.(DCSG00150322)
-[Aero][Pldm] Print Implementation.(DCSG00012331)
-Aero-3: Add debug prints to display SerDes Tx parameters.(DCSG00041624)
-Aero SAS Performance Enhancement on AMD Rome as part of PR.(DCSG00064583)
-MPI 2.6: Header file changes associated with Revision 2.6.9 of the specification.(DCSG00024640)
-[Aero][Pldm] Clean PLDM make files.(DCSG00007514)
-PLDM: Implement generic string and linked list utility functions.(DCSG00056271)
-Disable Active Cable Mgmt. IntL GPIO configuration from default NVDATA.(DCSG00014807)
-Optimizing LIBZ Make.(DCSG00035135)
-SPILIB 2.0: Add capability to support Winbond Parts with Factory Quad bit Disabled.(DCSG00140236)
-Serial mode support for S25FL512S SPI flash part.(DCSG00054211)
-Create PLI interrupt handler timestamp log.(DCSG00008208)
-Advertise certain Secure Boot Properties using a config page for Application to be able to display it.(DCSG00078835)
-PLDM: Implement Redfish PDRs and APIs.(DCSG00060505)
-Aero/Ventura IT: Optimize space by accessing non-IO path data directly from FLASH.(DCSG00025793)
-SPILIB 2.0: Add support for Block Protect bits configuration.(DCSG00170752)
-SPILIB2: Add support for Macronix MX25U25691G part.(DCSG00068680)
-pl: NVMe: fail NVMe init if device requires too much power.(DCSG00016416)
-pl: update combo serdes library.(DCSG00011562)
-Check if all BP slots and drives are discovered after FW upgrade.(DCSG00087155)
-Implement Debug routines for PLDM Type-5 Module.(DCSG00027039)
-Added Carriage Return (\r) in PLDM common library debug strings.(DCSG00069752)
-Queue Depth Change for SAS Drives (fix for SAS SMR TSF performance).(DCSG00015057)
-pl: backend PCIe: reconfiguration of PCIe address space without adapter reset.(DCSG00023737)
-Integrate MPI 2.6.10 headers into Ventura/Aero code.(DCSG00034259)
-Ventura/Mercator: backend PCIe: enhance robustness of PCIe port status tracking.(DCSG00018437)
-Added CoreDump collection on IT-FW fault.(DCSG00023671)
-PL logic to create VSES instances per Backplane number.(DCSG00069245 (Port Of EnhancementRequest DCSG00076941))
-Update Sea Channel XMLs to PCI Device ID 0xE6.(DCSG00079238 (Port Of EnhancementRequest DCSG00086622))
-Aero3: SecureBoot BIOS Image Download with new Key is failing.(DCSG00233694 (Port Of EnhancementRequest DCSG00234374))


Version  13.01.00.00
---------------
    BIOS            Firmware      UEFI Driver   
 09.25.00.00      13.00.01.00    13.00.00.00
Phase 13

Defects:
BST: FW revision not updated correctly.(DCSG00019620)
BST: POR System reboot information is cleared as part of clean up.(DCSG00019956)
Fault 0x265d seen when the UBM FRU I2C read size configured to 2 bytes..(DCSG00026985)
BST: Activity auto BST on Ventura/Sea channel cards failing.(DCSG00031344)
BST: Improved argument parsing.(DCSG00031604)
BST: error on import sys module missing.(DCSG00032512)
BST: check_devs function call update.(DCSG00054198)
BST: Fix the compilation error for UBM BST(DCSG00062522)
Ventura B0: ISTWI Error observed during controller cable management initialization.(DCSG00042683 (Port Of Defect DCSG00041605)
Locate PD fail on SGPIO enclosure when GroupId is disabled in Nvdata..(DCSG00044445 (Port Of Defect DCSG00034489)
Ventura B0: Device discovery fails on 9400-16e.(DCSG00045780 (Port Of Defect DCSG00045385))
UBM: Incorrect slot number enumerated for a DFC on 3 x4 DFCs UBM config.(DCSG00048741 (Port Of Defect DCSG00048027)
Ventura B0: sg_scan does not report all vSES devices in a multi-UBM configuration,(SCGCQ02165639)
Ventura B0: Windows Driver error 44802 seen on 2019 server power up with UBM present.(SCGCQ02151086)
UBM1005: PCIe reset sent incorrectly to DFCs on status change reported for other DFC..(SCGCQ02155883)
BSOD observed when opening disk management in Win 10 OS..(SCGCQ02160135)
Avoid releasing I2C bus when I2C operation(Read/Write) in progress.(SCGCQ02156466 (Port Of Defect SCGCQ01721931)
Turned off UBM and vSES console prints..(UBM prints are enabled)
PL: SAS topology error - Device not addressable.(SCGCQ02150249 (Port Of Defect SCGCQ02138806)
SERDES Transmit Equalization values update results in invalid Transmit Equalization values being set.(SCGCQ02082083)
Ventura/Aero: Application hits an assert when a UBM VSES device is present.(SCGCQ02146190)
NVMe Drive goes missing after running PD Pull Push Script in loop.(SCGCQ02142577 (Port Of Defect SCGCQ02123786)
Aero A0: SES page 0xA incorrectly displays "no SAS Device attached" after drive pulls.(SCGCQ02144033 (Port Of Defect SCGCQ02141415)
Aero: Running various Task Managements and Receive Diagnostics of SES pages (0Ah) to Atlas SES behind Aero causes 0x6001 fault.(SCGCQ02144873 (Port Of Defect SCGCQ02126050)
pl: backend PCIe: revert MRRS change for Ventura/Mercator.(SCGCQ02141791)
Aero: Memory Move toolbox request returns INVALID_SGL for Signal Integrity.(SCGCQ02141507 (Port Of Defect SCGCQ02139651)
Incorrect slot numbers reported for HBA attaching to UBM backplane with connector lanes reversed.(SCGCQ02123236)
Ventura B0: Observed 0x265D fault while running IO_TM script.(SCGCQ02124882)
Aero A0: Flashed 11.250.15 FW on Aero (SEA) and it shows up as 11.250.14.(SCGCQ02139320)
0x7C41 fault while running SES requests and Task Managements to VSES and Atlas SES (Aero only).(SCGCQ02139228 (Port Of Defect SCGCQ02126874)
MR PA6 PLDM: Invalid completion code returned on Activating Firmware in ReadyXfer State prior to image transfer.(SCGCQ02102848)
Unable to handle 2nd component (BIOS) firmware request properly.(SCGCQ02105475)
MR PLDM Type 5:Fatal firmware error: Hitting PLDM Fault 0x29.(SCGCQ02107490)
PLDM Firmware Update Exception when ActivateCommand is sent twice..(SCGCQ02116632)
PLDM: Fix IT compilation issue.(SCGCQ02117651)
Memory alignment issues in PLDM library.(SCGCQ02135796)
Version number in Ventura FW not updated.(SCGCQ02138717)
pl: backend PCIe: fix a few issues uncovered by bad clocking mode test.(SCGCQ02138141 (Port Of Defect SCGCQ02132132))
PLDM: Design and Implement print infrastructure.(SCGCQ01987045)
Included new data types and API for PLDM applications usage(SCGCQ02023065)
PLDM Firmware Update application Add Assert functionality(SCGCQ02045097)
PLDM: MCTP API changes to support PLDM Transport Binding(SCGCQ02069745)
PLDM: Implementation of PLDM Transport Binding Layer.(SCGCQ02077190)
Implement PLDM for Platform Monitoring and Control (Type 2) Application module - Phase 1.(SCGCQ02087229)
PLDM: APIs for print and Assert Failed function.(SCGCQ02089390)
Add PLDM Event generation support to PLDM Common Framework App (Type 2 - Monitoring and Control).(SCGCQ02099275)
PLDM: Move generic routines from PLDM Type-2 App module to PLDM Base module.(SCGCQ02115686)
PLDM: Update entity content table with new field.((SCGCQ02115779))
PLDM: Implement print framework for Type-2 application module(SCGCQ02117497)
PLDM: Gaurd Type 2 application module specific directories and source files within an environment variable.(SCGCQ02126665)
PLDM: Move pldmDebugTmpl.h and pldmDebugTmpl.c to a separate folder.(SCGCQ02128176)
[Aero][Pldm] Platform changes to align with Print and Assert API changes done in PLDM library.(SCGCQ02138411 (Port Of EnhancementRequest SCGCQ02129020)
[Aero][Pldm] Integrate perl script to generate pldm debug files needed for PLDM lib.(SCGCQ02138414 (Port Of EnhancementRequest SCGCQ02128993))
BST: Feature to run BST on specific adapter broken.(SCGCQ02123424)
Ventura B0: Windows Driver error 44802 seen on system power up in UBM multi-vSES configuration.(SCGCQ02132332)
MR 7.11 : Vendor ID is not shown properly in SLT enclosure details..(SCGCQ02115831)
Controller resets in loop when connected to VPP Backplane.(SCGCQ02117890)
0x6016 Fault doing Individual Lane Break Testing.(SCGCQ02132164 (Port Of Defect SCGCQ02124056)
UBM state machine gets into loop when slot power is turned ON through sg_ses utility command..(SCGCQ02106481)
Windows OS Event:44801(Warning) logged for duplicate Enclosure events.(SCGCQ02123147 (Port Of Defect SCGCQ02119237)
Add bit widths to pl eminfo.(SCGCQ02126079)
Only compare hash size for sblib authenticate.(SCGCQ01965627)
Fix Static Tool Analysis reported defect # 22144 in Aero Sblib Project.(SCGCQ02045196)
Fix Static Tool Analysis reported defect # 22142 in Aero Sblib Project.(SCGCQ02045219)
Fix Static Tool Analysis reported defect # 22143 in Aero Sblib Project.(SCGCQ02045222)
Fix Static Tool Analysis reported defect # 22141 in Aero Sblib Project.(SCGCQ02045223)
sblib: Use image flashSize instead of dataSize.(SCGCQ02063185)
Add embedded key verification to pending key update check and authenticate image routine.(SCGCQ02063334)
NVMe: Log Sense command failed to get Self test results page 0x10 on SMART supported NVMe device.(SCGCQ02117944)
Task management timeout detected on TMs sent to VSES devices.(SCGCQ02123287)
Aero3: SES page 0xA shows "no SAS Device attached" in "SAS Device Type" field after drive pull.(SCGCQ02123333)
pl: backend PCIe: discovery reentrancy check.(SCGCQ02125801)
Performance drop observed with expander attached topology in latest firmware..(SCGCQ02122923 (Port Of Defect SCGCQ02105245))
0x6231 Fault while doing cable pulls on expanders.(SCGCQ02114729)
0x6001 Fault while running IOs and Task Managements to VSES devices.(SCGCQ02116225)
Ventura B0: After setting fault bit using sg_ses command drive amber LED is not lit.(SCGCQ02116309)
Aero DDR: ECC disable and half mode operation fails Valvano-8e cards.(SCGCQ02118088)
UBM1005: Connector module not set for 2Wire reset GPIO function in NVDATA Mfg page 6.(SCGCQ02118185)
pl: backend PCIe: 265D fault on switch removal.(SCGCQ02118688)
pl: backend PCIe: additional robustness for timer usages during discovery.(SCGCQ02121597)
Aero: backend PCIe: need workaround for PDB duplicate posted TLP issue.(SCGCQ02115996 (Port Of Defect SCGCQ02114403)
TM to Managed Switch SES (Atlas SES) not always cleaning up resources tied to IO.(SCGCQ02094359)
Aero3: MPI Initialization of a managed switch's MPI Device fails to stop when an MPI Configuration Read
fails.(SCGCQ02097408)
Aero DDR: Intermittent 0x4c2 (read fifo training) failures on Valvano-8e cards.(SCGCQ02097948)
Ventura B0: sg_utils does not display vSES created for PCI switch.(SCGCQ02101219)
BST: Deleting partitions on every drive without checking if the drive is partitioned or not.(SCGCQ02103060)
UBM1005 - RefClk is not enabled for HBA Conn Quads 3 & 4 when in x16 HFC I2C mode.(SCGCQ02104154)
pl: NVMe: task management timeout if device fails to go idle after hot reset.(SCGCQ02108935)
Ventura: Observed 265D fault while swapping the Elrond HFC cables.(SCGCQ02110231)
BST: Error seen while running BST when MR card is present in BST topology.(SCGCQ02112334)
pl: backend PCIe: switch attached device is unexpectedly removed after a link glitch.(SCGCQ02112757)
PL: Phy break under DMD time with Atlas switch behind Aero can cause driver to not unblock IOs to NVMe
drives behind switch.(SCGCQ02081147 (Port Of Defect SCGCQ02058234))
The locate functionality does not work for the bad PD connected to the slots 4-7..(SCGCQ02103480 (Port Of Defect SCGCQ02053027)
0xD101 Fault running IOs to VSES devices.(SCGCQ02100891)
[Aero][PLDM][Type5] Fault 0x8A01 Stack Frame: FE703D40 on sending Invalid command in Learn
Component State.(SCGCQ02105471)
Aero3: BST fails due to batch script warnings.(SCGCQ02115221)
pl: Remove SFF-TA-1005 UBM related prints.(SCGCQ02035572 (Port Of Defect SCGCQ02020270)
Ventura: Includes file uses internal SPI library header instead of API.(SCGCQ02105621)
Aero: Build zips the Ventura CFGI and MSS files instead of the aero files.(SCGCQ02110233)
Aero A0: Fault D024 observed during individual lane break test on Vendor Gen4 NVMe drive.(SCGCQ02042818)
pl: backend PCIe: various faults may occur with poor quality links.(SCGCQ02089264)
Storcli UEFI Mode "erase all" is not working for Aero controller.(SCGCQ02090167)
Properly handle the case where the trace buffer RAM head pointer is found to be pointing to the local trace
buffer's signature region while copying existing ring buffer entries to the diagnostic trace buffer..(SCGCQ02102995)
pl: backend PCIe: fix usages of PL_PCI_LINK_IS_VALID macro.(SCGCQ02105773)
PL: Port field is not populated in SAS IO Unit Page 0 read.(SCGCQ02100946 (Port Of Defect SCGCQ02084264))
Swap Bit Value in VSES Page 0x2 is incorrect.(SCGCQ02103577 (Port Of Defect SCGCQ02081299)
Aero PLDM OOB BMC Emulator: MR Firmware allows to change Header Version in PLDM header.(SCGCQ01891752)
Fixed issue in PLDM Library where Get PLDM Commands cmd with Invalid PLDM Version returns error.(SCGCQ01904115)
Orion MR PA5: Assertion failure in fw\cpu\arm\exceptions.c on Injecting error to datagram bit in PLDM
request Packet.(SCGCQ02044607)
pl: backend PCIe: EC84 fault.(SCGCQ02071058)
[Aero][PLDMLib] Crash in pldm scheduler observed.(SCGCQ02081302)
PLDM library compilation.(SCGCQ02084475)
pl: backend PCIe: ED06 fault.(SCGCQ02094366)
BST: Attempts to delete all partitions (if present) in BST topology..(SCGCQ02098690)
Aero: backend PCIe: discovery failure following direct attached link break.(SCGCQ02101632 (Port Of Defect SCGCQ02096973)
PLDM Firmware Update application initialization implementation.(SCGCQ01958882)
Create a stream for code integration and unit test for OOB_Common.(SCGCQ01973963)
PLDM Firmware update Implement QueryDeviceIdentifiers, GetFirmwareParameters, RequestUpdate and
PassComponentTable.(SCGCQ01974004)
PLDM Firmware update Implement UpdateComponent, RequestFirmwareData, TransferComplete and
VerifyComplete.(SCGCQ01985716)
PLDM Firmware update Implement ApplyComplete, ActivateFirmware, GetStatus, CancelUpdateComponent
and CancelUpdate.(SCGCQ01986821)
Doxygen build set up for oob_common.(SCGCQ01987068)
PLDM: Local variables need to start in lower case for PLDM Base Module.(SCGCQ02029342)
[Aero][PLDM] FW update via OOB,PLDM type 5 support and PLDM library integration.(SCGCQ02032309)
PLDM Firmware Update application Bit fields to be added in a structure and intern in a union.(SCGCQ02038143)
PLDM Firmware Update application split pldmRspFromShimLayerProcess to small function.(SCGCQ02045010)
PLDM Firmware Update application add functions to modify fields in gPtrPldmFwUpdateInfo.(SCGCQ02047722)
PLDM Firmware Update application UUID and UTC_TIME structures to be moved to base module.(SCGCQ02049867)
[Aero][PLDM] Implement code to init PLDM FWUpdate module and Register the MCTP interface with
PLDM library.(SCGCQ02053715)
PLDM: Introduction of pldmiPlatformApi.h.(SCGCQ02053921)
Add support for UBM backplane HFC port bifurcation feature.(SCGCQ02071918)
Create documentation file for PLDM Firmware update module.(SCGCQ02083065)
Update Ventura summary release notes for phase 11.(SCGCQ02099989)
[Aero] Enable NVData fields to customize/enable/disable of the Host-Trace-Buffer (HTB) for Aero Eval board.(SCGCQ02102809)
Potential high bit errors observed in optical SAS topology.(SCGCQ01984973)
BST: BST failing on every pass run.(SCGCQ02064114)
BST: FW Download/Diag reset failures are not caught decently.(SCGCQ02066449)
Inframe SGL translation of an MPI SCSI IO to Atlas SES can go beyond the frame with Chains..(SCGCQ02084058)
Aero/Ventura: Drives missing after firmware update due to incorrect phy masks.(SCGCQ02089290)
0xD015 fault when obtaining SES Page 0Ah from Atlas SES in an infinite loop from a host.(SCGCQ02095959)
PL SATA: A Target Reset is Sometimes Not Issued After First SATA Init Timeout.(SCGCQ02083509 (Port Of Defect SCGCQ02083265))
Aero3: Atlas SES fails to show in Event Replay from PL.(SCGCQ02093611 (Port Of Defect SCGCQ02079431))
Aero3: TM to Managed Switch SES (MPI attached device) picks up IOs that have already completed.(SCGCQ02093663 (Port Of Defect SCGCQ02083600))
Aero A0 UTP2 - PL Fault 0000e40e seen in phy break test.(SCGCQ02096187 (Port Of Defect SCGCQ02053077)
SATA Only : GET PHYSICAL ELEMENT STATUS command fails if allocation length/host buffer size is less
than 512 bytes.(SCGCQ02031199)
Aero/Sea FW faults on Diag Reset When any Cable Attached is to Controller.(SCGCQ02080963)
Aero DDR: Problem with DDR_INIT_USE_HIGH_TEMP_REF flag.(SCGCQ02083515)
Ventura B0: SES Page A does not report DA NVMe drive details.(SCGCQ02085294 (Port Of Defect SCGCQ02073743))
Enclosure Ids not shown in storcli output for the drives connected in DA SEP Backplane.(SCGCQ02085568 (Port Of Defect SCGCQ02056095)
pl: NVMe: unexpected task management halt or E40E fault.(SCGCQ02089266 (Port Of Defect SCGCQ02080182)
Aero: backend PCIe: change PCIe reference clock output driver settings.(SCGCQ02089283 (Port Of Defect SCGCQ02087884)
IO and TM timeouts observed while running IOs.(SCGCQ02017279)
Aero3: Allocation of Atlas SES Device Handle can use one reserved for multi-VSES.(SCGCQ02078856)
Aero: backend PCIe: transmit SSC unexpectedly disabled.(SCGCQ02079125)
pl: duplicate target device slot numbers when slot numbers are 256 or larger.(SCGCQ02081018)
Aero DDR: EVENT_N IO configured incorrectly.(SCGCQ02082058)
Fault 0x265D observed during port enable with direct attached SEP devices connected..(SCGCQ02063699 (Port Of Defect SCGCQ02057911)
PL: SAS Drive Never Spun Up.(SCGCQ02070686 (Port Of Defect SCGCQ02050654)
PL SATA: Overlapped ATA Commands Leads to Incorrect Identify Data For Certain Drives.(SCGCQ02071840 (Port Of Defect SCGCQ02033575)
Expander is removed when a Phy is removed from a valid zone during discovery.(SCGCQ02076676 (Port Of Defect SCGCQ02064073))
Aero FW does not allow the EscapePassthrough bit to be set in the Target Assist message.(SCGCQ02077305 (Port Of Defect SCGCQ02076583)
PL: FPE IO Timeout Following SCSI ATA Passthrough Command for Same Device.(SCGCQ02078823 (Port Of Defect SCGCQ01965930))
UBM: With single connector to Ex1 backplane only every other slot's Locate LED can turn on.(SCGCQ02082699 (Port Of Defect SCGCQ02066784))
Ventura: Avoid recursive callbacks of IOP ISTWI IO completions.(SCGCQ01750224)
pl: NVMe: write cache control during device initialization.(SCGCQ01985437)
Aero/Ventura: Break UBM backplane FRU data read in to smaller chunks.(SCGCQ02061600)
Move CFGI debug prints out of IOP print subsystem.(SCGCQ02061709)
Shenandoah Dual FW Image - MR CBB Support for Flash Silent Errors Recovery.(SCGCQ02063343)
(SATA Only) Add NCQ Support for SMR Zone Management Commands.(SCGCQ02074654)
pl: backend PCIe: additional thoroughness for switch duplicate slot number detection.(SCGCQ02076207)
pl: backend PCIe: vary MRRS with root port attachment.(SCGCQ02076675)
Connect Managed Switch (Atlas) SES Page 0Ah translations to SES Diagnostic Buffer in PL.(SCGCQ02078617)
Aero/Ventura: Support both Aero and Ventura PL in the same RO for Phase12.(SCGCQ02080241)
Aero/Ventura: Support both Aero and Ventura IT images in one RO.(SCGCQ02081124)
Update NVMe Device Requirements document builder.(SCGCQ02083530)
PL SATL: Add Nvdata Option to Disable Sanitize Features for SATA Drives.(SCGCQ02071838 (Port Of EnhancementRequest SCGCQ02069286)
NVDATA option for connector lanes to Phy mapping for UBM DFC link configuration.(SCGCQ02071847 (Port Of EnhancementRequest SCGCQ02055244))
SCSI Inquiry for VSES representing UBM BP -- HBA.(SCGCQ02071848 (Port Of EnhancementRequest SCGCQ02055352))
Add the ability to poll for DA SEP and UBM I2C backplanes.(SCGCQ02071849 (Port Of EnhancementRequest SCGCQ02056953)
PL: Backplane Bay ID number for VSES representing UBM BP(s).(SCGCQ02078756 (Port Of EnhancementRequest SCGCQ02055364)
Aero DDR: (Coverity) Assigning value, but stored value is overwritten before it can be used in mssMain().(SCGCQ01957239)
Aero DDR: (Coverity) Assigning value, but stored value is overwritten before it can be used in
mssiMcPreInit().(SCGCQ01957243)
Coverity defects in Misc IOP Files.(SCGCQ01957633)
Aero DDR: Coverity bugs in MSS files.(SCGCQ01957634)
Fix ISTWI code to work with PSOC download from storcli.(SCGCQ01976251)
SGPIO Slot Locate functionality not working on Aero/Sea Controllers.(SCGCQ02024727)
Multi-VSES: Misc fixes and updates.(SCGCQ02030141)
PL: SCSI ATA Passthrough command hangs with higher than expected DataLength.(SCGCQ02030158)
Aero-3: Serdes not disabled properly on the upper 8 phys of an 8 phy SKU.(SCGCQ02032503)
Aero DDR: Firmware hangs with Multiple ECC Errors in Aero 16i card.(SCGCQ02035141)
Ventura: Create NVDATA option to switch from single VSES to multi-VSES management for unmanaged
PCIe Switch enclosures..(SCGCQ02035960)
0x4308 Fault occurs when accessing various config pages before discovery has completed.(SCGCQ02035973)
Aero: backend PCIe: lane margining watchdog timer may expire prematurely.(SCGCQ02042575)
Phase11 Ventura B0: Duplicate Help message entry in UART.(SCGCQ02043820)
pl VSES: Fault 0x4456 observed with un-managed switch connected to a Ventura HBA.(SCGCQ02043944)
Aero-3: Ventura version used for Aero CFGI library.(SCGCQ02043946)
Disparity errors when testing with optical cables.(CGCQ02044151)
[Aero][PLDM] Unblock the PLDM timer.(SCGCQ02046108)
Aero DDR: Leveling timeout occurs intermittently during Read Leveling tests.(SCGCQ02048128)
pl: backend PCIe: VSES device is created for Atlas managed switch.(SCGCQ02048251)
VSES: Locate command to NVME drive in UBM backplane fails.(SCGCQ02053131)
Fault 0x265D while executing 'pl dbg' CLI diag command..(SCGCQ02056409)
Aero3: (IOP) HW Workaround:Unexpected link recoveries may occur when ASPM L0s is enabled on link.(SCGCQ02063393)
Ventura Ph12 tip build all broken due to single VSES mode changes.(SCGCQ02066656)
PDB data path parity error workaround.(SCGCQ02018096 (Port Of Defect SCGCQ01733783)
MCTP: MCTP over PCIe VDM Discovery can fail if Set EID and Port Enable collide.(SCGCQ02033198 (Port Of Defect SCGCQ02029912)
SIGNED FW fails to calculate the hash for the image correctly.(SCGCQ02046578 (Port Of Defect SCGCQ02032484)
PL: Repeating Internal Task Managements Loginfo 0x31110E05.(SCGCQ02053559 (Port Of Defect SCGCQ02021490)
Ventura B0: sg_utils doesn't show either of the two vSES in Win2k16 when Ex1 and Ux4 with different BP
types are connected.(SCGCQ02054140 (Port Of Defect SCGCQ02035948)
Ventura B0: Only one VSES shows up in Linux with latest PL FW on Start of the Day.(SCGCQ02056486 (Port Of Defect SCGCQ02048217)
VSES for PCIe Switch is not reported in Linux OS.(SCGCQ02058230 (Port Of Defect SCGCQ02056673))
Aero: device side phys may fail to link up.(SCGCQ02058350 (Port Of Defect SCGCQ02050426))
Ventura B0: Drives mapped to incorrect Enclosure when CSW quads are attached to UBM backplane with
different BPTypes.(SCGCQ02059740 (Port Of Defect SCGCQ02056956)
Multi-VSES: One of the drive connected to UBM x1 BP Enclosure may report on a different Enclosure.(SCGCQ02061943 (Port Of Defect SCGCQ02061648))
SCSI VPD B2 inquiry LBPRZ field is not set correctly for NVMe drives.(SCGCQ02063493 (Port Of Defect SCGCQ02063217)
SATA SMR: FIS Ported Zone commands execute in NCQ mode even when NCQ is disabled.(SCGCQ02064013 (Port Of Defect SCGCQ01998969))
PL PCI: Data Abort Exception when accessing some PCIe Config Pages right after starting Port Enable.(SCGCQ02064068 (Port Of Defect SCGCQ01971150)
Ventura B0: Locate LED cannot be turned off after diag reset with multi-VSES code.(SCGCQ02066472 (Port Of Defect SCGCQ02053404)
PL fault 0x6001 observed with heavy IOs to some NVME drives with Async events.(SCGCQ02069487 (Port Of Defect SCGCQ02057418)
Enclosure Information of particular OEM enclosure is displayed as 'Unknown' in UEFI HII.(SCGCQ02069504 (Port Of Defect SCGCQ02062907)
Aero UTP BST failure: 265d fault on init when UBM backplane is present.(SCGCQ02070663 (Port Of Defect SCGCQ02069253)
PL: SES direct attach initialization ring buffer print can access uninitialized pointer.(SCGCQ02071136 (Port Of Defect SCGCQ02060017))
pl: backend PCIe: traffic resumes prematurely following MemWr TLP error.(SCGCQ02071213 (Port Of Defect SCGCQ02061771)
pl: backend PCIe: EC73 or ECCB fault.(SCGCQ02073074 (Port Of Defect SCGCQ02069165)
Aero-3: Serdes parameters from NVDATA are not sent to Serdes.(DCSG00022778)
Backplane detection never completes leading to discovery timeout..(DCSG00023081)
Ventura B0: vSES goes missing after the first controller reset on UBM Ex1 in x8 HFC config.(DCSG00024555)
Ventura B0: vSES not reported in Windows 2019 on certain UBM backplane config.(DCSG00026333)
On Locating PD's,LED's are not blinking for drives connected to customer specific SGPIO Backplane..(DCSG00018823)
Ventura B0: Incorrect VSES associated to unmanaged PCIe SW enclosure.(DCSG00023764)
pl: NVMe: E425 fault after vendor specific device firmware update.(DCSG00012593)
0x6231 Fault during Sata Task Management.(DCSG00019315)
Aero: Powered cycled managed switch SES can become inaccessible.(DCSG00021412)
UBM Link Config may fail for HBA connector with Phys routed spans CSWs.(DCSG00022691)
pl: backend PCIe: EC5B fault.(DCSG00022805)
[Aero]Remove NVMe support for SAS/SATA profile only.(DCSG00022886)
Aero: PL cannot handle very large SES Page 0Ah from Managed Switch SES for MPI SEP Request.(DCSG00012692 (Port Of Defect DCSG00010049))
PL: Device removal event is not sent for hot removed end device.(DCSG00023450 (Port Of Defect DCSG00023448)
Atlas behind Aero IT: Fault code: 0x4000EDAC while running IOs and TMs..(DCSG00023799 (Port Of Defect DCSG00022533)
pl: NVMe: unexpected task management halt may occur.(DCSG00014455)
Multiple VSES created on SAS only 8-Slot UBM backplane with duplicate slot assignments.(DCSG00017373)
Channel SAS3.5 HBAs cannot support published PD limits when loaded with SAS/SATA-only FW image.(DCSG00020917)
Aero: NVMe: device not removed if init fails and it then goes missing.(DCSG00013404)
PLDM: Pass Timer-id that needs to be restarted to Pldm-timer-restart operation.(DCSG00018645)
Build error in PLDM Library on ARM 4.1 compiler (done with Atlas FW code).(DCSG00019014)
pl: backend PCIe: 'pl pci dbgall' causes ring buffer spam.(DCSG00019925)
pl: backend PCIe: IO halt following temporary device removal.(DCSG00015943)
Aero: backend PCIe: 265D fault if PCIe Device Page 2 is read for a SES device.(DCSG00016108 (Port Of Defect DCSG00016069))
UBM Auto HFC grouping fixes and debug print fixes.(DCSG00017558 (Port Of Defect DCSG00012363))
Aero A0: vSES is created even for managed Atlas (Ibanez) switch.(DCSG00012487)
Scrutiny GUI clear option fails to reset the PCIe error counters.(DCSG00014510)
VSES may not report valid SES Page 0Ah elements for one of quads attached elements in a UBM backplane.(DCSG00013123)
pl: discovery failure if PCIe backplane detection is disabled.(DCSG00013397)
pl: NVMe: fix a couple of debug issues related to unique identifiers.(DCSG00014628)
Aero: Various faults occur with PCIe clock configuration mismatch between Aero and managed switch (Atlas).(DCSG00012416 (Port Of Defect DCSG00012378)
Aero: Error on posting a SCSI IO request to Atlas SES can cause IO forever being pended.(DCSG00012962 (Port Of Defect DCSG00012605))
Unable to detect drives behind Sea controller during Windows installation.(DCSG00013165 (Port Of Defect DCSG00012569)
pl: backend PCIe: debug prints.(DCSG00014212 (Port Of Defect DCSG00013387)
VSES may not report valid SES Page 0Ah elements for one of quads attached elements in a UBM backplane.(DCSG00013123)
Aero: Various faults occur with PCIe clock configuration mismatch between Aero and managed switch (Atlas).(DCSG00012416 (Port Of Defect DCSG00012378))
Aero: Error on posting a SCSI IO request to Atlas SES can cause IO forever being pended.(DCSG00012962 (Port Of Defect DCSG00012605))
Unable to detect drives behind Sea controller during Windows installation.(DCSG00013165 (Port Of Defect DCSG00012569))
[Aero][Pldm] Print Implementation.(DCSG00012331)
Unaddressable Device error status seen with some OEM enclosures.(DCSG00008628)
Ventura B0: VSES created for every unmanged SW in Mfg 46 single VSES mode.(DCSG00009462)
Aero: backend PCIe: disallow DPC for PCIe 3 and earlier specific vendor switches.(DCSG00010608)
pl: UBM SAS max link rate update to phys fails.(DCSG00011896)
PL: Insertion events for some drives in UBM have the wrong enclosure handle.(DCSG00011898 (Port Of Defect DCSG00011802)
pl: backend PCIe: legacy interrupt may not be serviced if interrupt mask fails.(DCSG00010071)
pl: fix unhelpful debug print.(DCSG00010298)
Aero A0: Controller fault EC57 observed on doing individual lane break test on VendorX Gen4 NVMe drive.(DCSG00010317)
IT_SF directory not present in Ventura release zip.(DCSG00010604)
pl: backend PCIe: IO halt following link break to Atlas switch.(DCSG00008198)
NVDATA in wrong location in MR release zip files.(DCSG00009013)
pl: NVMe: incorrect WWID may be assigned to a device.(DCSG00007994)
Aero: PL Fault 0x6001 when issuing Task Managements that are for a SES Page 0Ah request to one of two managed switch SESes.(DCSG00008044)
pl: NVMe: incorrect WWID may be assigned to a device.(SCGCQ02172945)
Discovery results in Unaddressable device status when connected to a certain enclosure.(SCGCQ02174565)
Aero: PL Fault 0x6001 when issuing Task Managements that are for a SES Page 0Ah request to one of two managed switch SESes.(SCGCQ02176633)
PCIe bitfield header file issues.(SCGCQ02135845)
PLDM: Fix Type 2 observations.(SCGCQ02147539)
Fault 0x6231 when connecting 8 Sata drives and booting server.(SCGCQ02152667)
Fix coverity compilation issue.(SCGCQ02162909)
pl: backend PCIe: disallow out of range config space access requests.(SCGCQ02172146)
PL: SATA Drives Not Detected on Boot with UBM.(SCGCQ02165721 (Port Of Defect SCGCQ02161663)
PLDM: Free allocated msg frame in Error Path (PLDM Base).(SCGCQ02135302)
PLDM: Fix Atlas compilation issues.(SCGCQ02140695)
virtual compilation issue.(SCGCQ02141961)
Incorrect number of VSES Slots displayed on connecting drives to UBM backplane.(SCGCQ02149219)
Aero: backend PCIe: EDAB fault.(SCGCQ02158782)
[VSES] 2 VSES devices are created when a single UBM backplane is connected with one NVME drive..(SCGCQ02162250)
Aero: backend PCIe: topo change list event suppressed if rediscovery occurs with an event pending.(SCGCQ02166755)
Ventura: PERST clamp is not enabled for Ventura.(SCGCQ02168728)
BSOD observed when opening disk management in Win 10 OS..(SCGCQ02162508 (Port Of Defect SCGCQ02160135)
Invalid Slot count seen in HII for UBM Enclosures.(SCGCQ02164289 (Port Of Defect SCGCQ02162429)
Ventura B0: sg_scan does not report all vSES devices in a multi-UBM configuration.(SCGCQ02168581 (Port Of Defect SCGCQ02165639))
PA2 Aero- PC with 8i controller rebooting ,While updating the windows Driver.(SCGCQ02095462)
Enclosure ID is not displayed for drives connected to UBM.(SCGCQ02142763)
pl: backend PCIe: Common Clock Configuration bit not set.(SCGCQ02149826)
Aero: backend PCIe: link bandwidth interrupt workaround should be compiled out.(SCGCQ02160408)
Aero: Fix build-all error caused by inclusion of new maverick.h into PL.(SCGCQ02162527)
Ventura B0: Windows Driver error 44802 seen on 2019 server power up with UBM present.(SCGCQ02155893 (Port Of Defect SCGCQ02151086))
Avoid releasing I2C bus when I2C operation(Read/Write) in progress.(SCGCQ02156470 (Port Of Defect SCGCQ01721931))
UBM1005: PCIe reset sent incorrectly to DFCs on status change reported for other DFC..(SCGCQ02157985 (Port Of Defect SCGCQ02155883)
Aero: backend PCIe: need small delay after enabling ref clock outputs.(SCGCQ02152323)
SPILIB: Errors seen when attempting to use AERO SPILIB NVSRAM at 100MHZ.(SCGCQ02153365)
pl: backend PCIe: config page handler reentry while reading PCIe Link Page 2.(SCGCQ02153414)
Aero: backend PCIe: port enable may time out.(SCGCQ02153618)
No debug print when IT's IOP rejects an IO to a device under task management.(SCGCQ02154189)
SATA : SATL does not send check power mode and sanitize status for request sense translation.(SCGCQ02056042)
SERDES Transmit Equalization values update results in invalid Transmit Equalization values being set.(SCGCQ02082083)
Aero: backend PCIe: modify PCIe SSC settings.(SCGCQ02094369)
MR PA6 PLDM: Invalid completion code returned on Activating Firmware in ReadyXfer State prior to image transfer.(SCGCQ02102848)
Unable to handle 2nd component (BIOS) firmware request properly.(SCGCQ02105475)
PL's MPI Device code fails to deallocate an SMID when an error is encountered sending the request.(SCGCQ02106760)
MR PLDM Type 5:Fatal firmware error: Hitting PLDM Fault 0x29.(SCGCQ02107490)
pl: backend PCIe: PCIe Link Page 3 ineffective when UBM backplane is present.(SCGCQ02116052)
PLDM Firmware Update Exception when ActivateCommand is sent twice..(SCGCQ02116632)
PLDM: Fix IT compilation issue.(SCGCQ02117651)
BST: Feature to run BST on specific adapter broken.(SCGCQ02123424)
0x6016 Fault doing Individual Lane Break Testing.(SCGCQ02124056)
Aero: Running various Task Managements and Receive Diagnostics of SES pages (0Ah) to Atlas SES behind Aero causes 0x6001 fault.(SCGCQ02126050)
Aero: Atlas SES resources not completely freed, leading to 0x6001 fault on SES Page 0Ah read after 5 Atlas add-removals.(SCGCQ02126066)
0x7C41 fault while running SES requests and Task Managements to VSES and Atlas SES.(SCGCQ02126874)
pl: backend PCIe: fix a few issues uncovered by bad clocking mode test.(SCGCQ02132132)
pl: backend PCIe: static analysis bugs in NVMe-related files.(SCGCQ02134118)
Memory alignment issues in PLDM library.(SCGCQ02135796)
pl: NVMe: Start Stop Unit may fail with pre-NVMe 1.1a devices.(SCGCQ02136965)
Aero: Internal Task Management to MPI Device (Atlas) hangs forever.(SCGCQ02138636)
GOLDENX: Goldenx is failing to failing to create flash image from valid signed Aero binaries.(SCGCQ02138689)
Aero DDR: Incorrect SPD translation for tRC.(SCGCQ02139292)
Aero DDR: Uncorrectable ECC errors encountered on fast silicon.(SCGCQ02139360)
Aero: Memory Move toolbox request returns INVALID_SGL for Signal Integrity.(SCGCQ02139651)
pl: backend PCIe: event and error counters are cleared on link down.(SCGCQ02140925)
Aero A0: SES page 0xA incorrectly displays "no SAS Device attached" after drive pulls.(SCGCQ02141415)
Aero DDR: Print PVT EFUSE data, but use static PVT.(SCGCQ02141718)
Misc PL Coverity Issues.(SCGCQ02144289)
(SATA) Possible null pointer dereference in SCSI Verify to ATA translation function..(SCGCQ02144896)
Aero: backend PCIe: fix a few dev testing issues.(SCGCQ02146903)
AeroSea release notes mention Sea raw images which do not exist.(SCGCQ02149798)
Aero: PL needs to hold off Port Enable while MPI Device (managed switch) is still initializing.(SCGCQ02151148)
PL: (SATA only) Proper Sense key not set to failed read/write command while handling NCQ error.(SCGCQ02128299 (Port Of Defect SCGCQ01763871))
Controller resets in loop when connected to Intel VPP Backplane.(SCGCQ02132593 (Port Of Defect SCGCQ02117890)
MR 7.11 : Vendor ID is not shown properly in SLT enclosure details..(SCGCQ02132920 (Port Of Defect SCGCQ02115831)
Ventura B0: Windows Driver error 44802 seen on system power up in UBM multi-vSES configuration.(SCGCQ02133155 (Port Of Defect SCGCQ02132332)
PL: SATA Drive is Not Spun Up and Discovered During Reboot Test.(SCGCQ02134278 (Port Of Defect SCGCQ02118430))
Ventura B0: Observed 0x265D fault while running IO_TM script.(SCGCQ02140902 (Port Of Defect SCGCQ02124882)
Incorrect slot numbers reported for HBA attaching to UBM backplane with connector lanes reversed.(SCGCQ02140963 (Port Of Defect SCGCQ02123236)
pl: backend PCIe: revert MRRS change for Ventura/Mercator.(SCGCQ02142407 (Port Of Defect SCGCQ02141791)
NVMe Drive goes missing after running PD Pull Push Script in loop.(SCGCQ02143845 (Port Of Defect SCGCQ02123786))
Ventura/Aero: Application hits an assert when a UBM VSES device is present.(SCGCQ02147803 (Port Of Defect SCGCQ02146190))
PL: SAS topology error - Device not addressable.(SCGCQ02150192 (Port Of Defect SCGCQ02138806)

Enhancements:
BST: UBM-VSES nightly BST at BLR.(DCSG00008010)
BST: Add NVMe cable breaker tests to BST suite.(DCSG00008099)
BST: Enhance debug and logging capability.(DCSG00008215)
BST: Add SAS-SATA cable breaker support to BST.(DCSG00012471)
BST: Add medusa error codes to be ignored during cable break.(DCSG00014442)
BST: Update scripts to run BST on Cisco Adapter.(DCSG00014609)
BST: python bst command re-issue on reboot needs automated on Manual run.(DCSG00019959)
BST: Notify user of existing BST run with a print..(DCSG00019961)
Modify the UBM BST code with respect to new BST scrutiny APIs.(DCSG00063258)
Controller hang observed while running heavy read/write IOs.(DCSG00044806)
BST: Update bst scripts to utlilize bst_utils file.(SCGCQ02113002)
BST: Delayed reboot using apc for rebooting the server.(SCGCQ02113941)
[Aero] Gracefully handle the MCTP-IIC control packets from BMC when functioning in OOB-IIC slave mode.(SCGCQ02140550)
Modify CBB builder for Avenger to add parameter for ETP binary image..(SCGCQ01735481)
Support ARM compiler toolchain installation with spaces in path as well as multiple perl binary names.(SCGCQ01760624)
SCons improvements.(SCGCQ01847730)
SCONS changes for ER:SCGCQ01856025 - Add CSW Aladin Plus FW to SBR portion of CBB image.(SCGCQ01856249)
SCons: Replace and remove perl based scripts with python equivalents.(SCGCQ01866136)
Add python path to genDebug.py call.(SCGCQ01870009)
Add builder to invoke SecureSign.exe utility in order to sign images..(SCGCQ01870088)
sblib: Audit for timeout loops.(SCGCQ01872112)
SCONS changes for signing APP-FW image on Avenger.(SCGCQ01889213)
Move dev versions out of the registry.(SCGCQ01913916)
Adding a new builder to SCONS script to pad firmware image and update header size at the same time.(SCGCQ01924957)
Allow environment variables to override yaml defines.(SCGCQ01924973)
Add support for an NVDATA image argument to the create CBB builder.(SCGCQ01927492)
Add SrkWriteProtect getter/setter to api.(SCGCQ01933404)
Modify aero-prevalidation to match table under Secure Boot Mode in Security Arch.(SCGCQ01958073)
MR sblib: Add Efuse Reset Interface in SbLib.(SCGCQ01971935)
Updated the version and rebuilt the binary to included updated signImageX executable and dll..(SCGCQ01985914)
Implemented generic signing for bin files used by Atlas FW build process to sign images with HSM-managed keys.(SCGCQ02007535)
Secure Sign: update SignImageX change for FMC.(SCGCQ02054080)
Add Build Time Print Statement Format Checking.(SCGCQ02059746)
Add fmc builder to scons.(SCGCQ02084261)
Aero: update SBLIB (+SCONS) and SecureSign to most recent releases.(SCGCQ02123191)
Aero:256K/1M performance lower than expected with SSDs.(SCGCQ02007385)
Ventura B0: StorCLI does not list 'Model' information for SATA drives.(SCGCQ02097328)
VSES: Unmanaged backplane multi-VSES mode has missing direct attach drives, but has PCIe switch
attach information in SES Page 0Ah(SCGCQ02098157)
0xD101 Fault running IOs to VSES devices.(SCGCQ02105742)
Aero: backend PCIe: enable SRIS by default in external IT channel board NVDATA.(SCGCQ02114564)
Aero: Add MRCBB build to Aero releases.(SCGCQ02123188)
Update scripts to execute Release/Nightly/Activity BSTs from a uniform BST build folder structure type.(SCGCQ02103868)
BST: Update por needed request when using storCli utility.(SCGCQ02104137)
Update PNP ID match algorithm to skip 2 least significant bits of PCI DeviceID field for Sea/Aero cards.(SCGCQ02105398)
BST: Update script to wait in a loop allowing SATA drives to come up after adapter reset(SCGCQ02108345)
AeroVentura: Eliminate unused library builds to decrease development time.(SCGCQ02108887)
[Aero][PLDM][Type5] Change the PLDM opcode handling from timers to scheduler.(SCGCQ02112316)
BST: Update script to allow only two BST configs and other misc changes.(SCGCQ02112537)
Ventura/Aero : Support Instant Secure Erase on non-fde ISE capable NVMe drives.(SCGCQ02066410)
I2C/2WIRE RESET# support for I2C backplane devices.(SCGCQ02071917)
(NVMe) Enable SMART Failure Prediction Data capability for NVMe drives..(SCGCQ02074644)
Added required code changes to support Multi component firmware download (firmware + BIOS)..(SCGCQ02099849)
SPILIB: Create a stack frame-based version of the library.(SCGCQ02102972)
Ventura CSW: Add stack frames to build.(SCGCQ02103865)
Replace hard coded APC details with test host specific APC config.(SCGCQ02010565)
Add support for Release order package based BST.(SCGCQ02011525)
DevBST: Add support to test single Ventura adapter card.(SCGCQ02012078)
BST: Update bst scripts to support por request.(SCGCQ02018624)
Recovery/Tear up process to get the server and controller in a known good state after a bst run.(SCGCQ02063488)
Support for Ventura based Activity BST.(SCGCQ02063797)
Framework to support Ventura based Customer Specific BST.(SCGCQ02063798)
Framework to support Sea based Activity BST.(SCGCQ02063799)
VSES: Support for SES Diag Page 07h and SAS connector element type.(SCGCQ02066446)
UART command "iop show ver" to also show BIOS/UEFI information.(SCGCQ02074642)
BST: Aero update/support for BST.(SCGCQ02082661)
SPILIB: Add SPI Library Parameter to Configure NVSRAM Frequency Settings.(SCGCQ02087717)
Aero/Ventura: Integrate SPILIB 10.00.01.00 into the build.(SCGCQ02096867)
Create a batch file for Aero channel images.(SCGCQ02097420 (Port Of EnhancementRequest SCGCQ02086489)
Add tag in the FW-Ring-Buffer messages to indicate error/warning/debug.(SCGCQ02030778)
Aero3: Ensure that Aero3 is properly configured to support non-ROMable (copied) code at SOD.(SCGCQ01938283)
Aero/Ventura: Dynamically determine the contents of MPB using Manufacturing Page 47.(SCGCQ01938663)
Create folder structure for oob_common.(SCGCQ01966264)
PLDM: Check in file for PLDM Modularization APIs.(SCGCQ01966265)
PLDM: Implement PLDM Msg type 0(Control and Discovery) handler.(SCGCQ01987042)
PLDM: Implement Base Infra.(SCGCQ01987044)
PLDM: Implements PLDM Task Scheduler.(SCGCQ01987047)
PLDM: PLDM Base Module Initialization.(SCGCQ01987048)
PLDM: Introduce pldmiTypes.h file.(SCGCQ02029344)
Aero3: Set default interrupt coalescing timeout value to 0x20 from 0xa in IOC Page1 for AERO/SEA HBA
devices.(SCGCQ02031573)
Aero: Create Sea 9500-8i Channel IT partial xml.(SCGCQ02041111)
Aero3: Prevent "rollback" of firmware revisions if a key update is pending.(SCGCQ02044165)
[Aero] PLDM Type 0 support to integrate PLDM library..(SCGCQ02044808)
[Aero][PLDM] Type 0 bld infrastructure.(SCGCQ02044848)
Aero: pl: new CSW M0 firmware image.(SCGCQ02046410)
Aero: new CSW M0 firmware image.(SCGCQ02047386)
Update Aero_AutoGenHWBoardImageConfig.xml and update 8 phy chip names.(SCGCQ02047631)
pl: backend PCIe: vary allocated bridge count with allocated switch count.(SCGCQ02047632)
Aero DDR: ESD issue with PVT requires hard coding PVT_COMP values.(SCGCQ02049006)
PACKAGE: Change version to 2.0.0.0 for release.(SCGCQ02049017)
Aero: backend PCIe: generate more link debug information.(SCGCQ02057014)
pl: backend PCIe: handle Atlas slot numbering changes.(SCGCQ02064046)
Aero: Port nvdumpx to Aero.(SCGCQ02066369)
Extend SATA Hinting to turn off after Port Enable is done.(SCGCQ02053403 (Port Of EnhancementRequest SCGCQ02046265)
Port changes from old db to new DB.(DCSG00014692)
[Aero][Pldm] Print Implementation.(DCSG00012331)
Ventura: Fix OEM Page7 Data.(DCSG00014014)
Aero/Ventura: Add auto-downgrade algorithm.(DCSG00010679)
pl: backend PCIe: allow override of backplane link config for debug.(DCSG00011555)
Ventura: Create a custom build script.(DCSG00012169)
Ventura: Fix OEM DeviceSpecific fields.(DCSG00012208)
Create a new firmware image that provides an AVSO setting of 0.997V.(DCSG00007958)
Aero: Add permissions to access additional registers for Scrutiny.(DCSG00008197)
Aero/Ventura: Misc debug fixes and enhancements.(DCSG00009402)
Aero: Add limited support for IEEE SGL chains that point to DDR memory for Managed Switch SES.(DCSG00010053)
Add PERST# clamp to nvdata.(DCSG00010069)
Aero: Add yet more ranges for scrutiny signal integrity.(DCSG00010274)
Update Sasparser path in additional files.(DCSG00010302)
Aero: check in ACM-enabled partial file for Sea eval board.(DCSG00010543)
pl: backend PCIe: enhance robustness of PCIe-related MPI event generation.(DCSG00009002)
Updated secureSign.exe CLI tool and server-side controller scripts to use GCP server resources.(DCSG00003371)
Check in MPI 2.6 2.6.9 Headers.(DCSG00005425)
Aero/Ventura: Build updates for migration to Google Cloud.(DCSG00007470)
SPILIB: Migrate paths to google.(DCSG00007475)
pl: backend PCIe: lspci-compatible debug output.(DCSG00007999)
pl: NVMe: changes related to NVMe unique identifiers.(SCGCQ01866825)
Add debug prints to the ringbuffer before faulting to provide important info on the initial failure.(SCGCQ02035995)
Added code to look for an error when asking the HW to modify a drive's IO count total.(SCGCQ02122155)
Ventura/Aero: Increase NVME Event Replay Robustness Concerning bad Switch Links.(SCGCQ02132425)
UBM1005: Auto detect and group HFCs based on number of DFCs supported by the UBM controller.(SCGCQ02140813)
To support PERST# master clamp signal.(SCGCQ02141807)
BST: Add logs locally on server of all bst runs..(SCGCQ02157380)
BST: Update existing BST host server names and add new host for UBM.(SCGCQ02163895)
pl: backend PCIe: move PCIe Topo Change List event debug prints to PL.(SCGCQ02165688)
Aero-3: Convert Adapter Reset of Atlas MPI Device into state machine.(SCGCQ01920225)
Ventura/Aero: Eliminate UBM1005, FRU and VSES prints to console in favor of RB.(SCGCQ02141641)
Binary trace format to support eTTY log - scons.(SCGCQ02145545)
Aero: Add Managed Switch SES (Atlas) handing for MPI SEP Request.(SCGCQ02151411)
Binary trace format to support eTTY log - scons.(SCGCQ02152652)
Ventura/Aero: Remove DDR functionality from IT firmware.(SCGCQ02154394)
MPI 2.6: Header file changes associated with Revision 2.6.9 of the specification.(SCGCQ02158611)
Increased HTTP timeout to 60 seconds.(SCGCQ02160446)
Integrate MPI v2.6.9 headers into Ventura.(SCGCQ02161739)
Suppress VSES (virtual SEP device) from being exposed to the host when there is no UBM backplane connected..(SCGCQ02063489)
Aero: Define new MPI Enclosure Page 0 Encl Management type for Managed Switch SES device.(SCGCQ02146320)
Remove non-stack frame versions of PL/SCS libraries.(SCGCQ02154424)
Move DA Enclosure mgmt timer callback handling to a faster timer callback.(SCGCQ01957623)
PLDM: Design and Implement print infrastructure.(SCGCQ01987045)
Included new data types and API for PLDM applications usage.(SCGCQ02023065)
PLDM Firmware Update application Add Assert functionality.(SCGCQ02045097)
SATA Write Cache enable/disable based on NVDATA.(SCGCQ02066767)
PLDM: MCTP API changes to support PLDM Transport Binding.(SCGCQ02069745)
PLDM: Implementation of PLDM Transport Binding Layer.(SCGCQ02077190)
BST: Reduced execution time of Activity bst.(SCGCQ02083575)
Implement PLDM for Platform Monitoring and Control (Type 2) Application module - Phase 1.(SCGCQ02087229)
PLDM: APIs for print and Assert Failed function.(SCGCQ02089390)
Aero3: Update channel board NVDATA for the wired-PDB workaround.(SCGCQ02090308)
Recognize logic level of new Alternative I2C Slave Address GPIO to change an ISTWI Controller's slave address on controller boot.(SCGCQ02097561)
Aero: Add code so BIOS version information prints during "iop show ver".(SCGCQ02097967)
Add PLDM Event generation support to PLDM Common Framework App (Type 2 - Monitoring and Control).(SCGCQ02099275)
Keep RefClk enabled for HBA connector Quads attaching to UBM indicating clock routing presence.(SCGCQ02111667)
BST: Update bst scripts to utlilize bst_utils file.(SCGCQ02113002)
BST: Delayed reboot using apc for rebooting the server.(SCGCQ02113941)
PLDM: Move generic routines from PLDM Type-2 App module to PLDM Base module.(SCGCQ02115686)
PLDM: Update entity content table with new field.(SCGCQ02115779)
PLDM: Implement print framework for Type-2 application module.(SCGCQ02117497)
pl: backend PCIe: add Link Configuration Source flag.(SCGCQ02124881)
PLDM: Gaurd Type 2 application module specific directories and source files within an environment variable.(SCGCQ02126665)
PLDM: Move pldmDebugTmpl.h and pldmDebugTmpl.c to a separate folder.(SCGCQ02128176)
[Aero][Pldm] Integrate perl script to generate pldm debug files needed for PLDM lib.(SCGCQ02128993)
[Aero][Pldm] Platform changes to align with Print and Assert API changes done in PLDM library.(SCGCQ02129020)
pl: backend PCIe: modify MPI/Discovery integration at completion of MPI init.(SCGCQ02132406)
Updated Man Page11 data struct: added HTB related fields to match with XSD/XML.(SCGCQ02132440)
[Aero][PLDM] PLDM Support controlled by NVDATA.(SCGCQ02132585)
pl: backend PCIe: dump PCIe-related config pages from the console.(SCGCQ02133045)
Aero: pl: backend PCIe: enhance robustness of PCIe port status tracking.(SCGCQ02134245)
Update Summary Release Notes For Phase 12.(SCGCQ02137201)
Aero: Extend the range of Memory Move toolbox for Signal Integrity.(SCGCQ02141419)
Aero3: Decrease Aero boot time by streaming flash reads.(SCGCQ02141443)
Release summary update: slot number is not correct when UBM is connected to expander - need to enable DSN.(SCGCQ02143623)
Aero/Ventura: Modify UBM state machine so that it doesn't create VSES when HFCInfo doesn't match.(SCGCQ02150907)
pl: backend PCIe: modify ref clock/PERST# control debug prints.(SCGCQ02152370)
[Aero] Gracefully handle the MCTP-IIC control packets from BMC when functioning in OOB-IIC slave mode.(SCGCQ02143761 (Port Of EnhancementRequest SCGCQ02140550))
Invalidate VSES SES Page 0Ah descriptors of unused controller Phys in the UBM backplane.(SCGCQ02144084 (Port Of EnhancementRequest SCGCQ02140929)
HBA FW to gracefully handle UBM reset/changes.(SCGCQ02147106 (Port Of EnhancementRequest SCGCQ02145211))


Version  11.02.00.00
---------------
    BIOS            Firmware      UEFI Driver   
 09.21.00.00      11.00.03.00    11.00.01.00
 
Defects (8)
 - BST: Attempts to delete all partitions (if present) in BST topology.(SCGCQ02098690)
 - BST: Deleting partitions on every drive without checking if the drive is partitioned or not.(SCGCQ02103060)
 - BST: Error seen while running BST when MR card is present in BST topology.(SCGCQ02112334)
 - BST: Feature to run BST on specific adapter broken(SCGCQ02123424)
 - BST: BST failing on every pass run(SCGCQ02064114)
 - BST: NVMe drives behind UBM goes missing after power cycling enclosures.(SCGCQ02158920)
 - BST: FW Download/Diag reset failures are not caught decently(SCGCQ02066449)
 - Controller hang observed while running heavy read/write IOs.(SCGCQ02208507)
 - System crash observed on performing firmware upgrade with auto port enable set.(SCGCQ02211930)

EnhancementRequests (19)
 - Add support for Release order package based BST(SCGCQ02011525)
 - DevBST: Add support to test single Ventura adapter card(SCGCQ02012078)
 - BST: Update bst scripts to support por request(SCGCQ02018624)
 - Framework to support Sea based Activity BST(SCGCQ02063799)
 - BST: Aero update/support for BST(SCGCQ02082661)
 - BST: Reduced execution time of Activity bst(SCGCQ02083575)
 - Update scripts to execute Release/Nightly/Activity BSTs from a uniform BST build folder structure type(SCGCQ02103868)
 - BST: Update por needed request when using storCli utility(SCGCQ02104137)
 - Update PNP ID match algorithm to skip 2 least significant bits of PCI DeviceID field for Sea/Aero cards(SCGCQ02105398)
 - BST: Update script to wait in a loop allowing SATA drives to come up after adapter reset(SCGCQ02108345)
 - BST: Update script to allow only two BST configs and other misc changes.(SCGCQ02112537)
 - BST: Delayed reboot using apc for rebooting the server(SCGCQ02113941)
 - Recovery/Tear up process to get the server and controller in a known good state after a bst run(SCGCQ02063488)
 - Support for Ventura based Activity BST(SCGCQ02063797)
 - BST: Update bst scripts to utlilize bst_utils file(SCGCQ02113002)
 - BST: Add logs locally on server of all bst runs.(SCGCQ02157380)
 - BST: Update existing BST host server names and add new host for UBM(SCGCQ02163895)
 - Replace hard coded APC details with test host specific APC config.(SCGCQ02010565)
 - Framework to support Ventura based Customer Specific BST(SCGCQ02063798)


Version  11.01.00.00
---------------
    BIOS            Firmware      UEFI Driver   
 9.21.00.00       11.00.02.00   11.00.01.00
UEFI driver is signed 
 
 - INLINE macro define in spiBaseType.h causes build error in Expander library build.(SCGCQ01884622) 
 - AERO: PL faults with 0x7211 after init with latest code(SCGCQ01991688) 
 - Aero: backend PCIe: link failure with vendor specific NVMe device(SCGCQ01983870) 
 - SPILIB: Winbond 128Mbit (16MB)(SCGCQ01890038) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906013) 
 - pl: backend PCIe: hot reset not issued on error if link is not fully initialized	(SCGCQ01914063) 
 - pl UBM: Ex1 Elrond SFF-TA-1005 UBM back plane with SAS drives only connected to a Ventura HBA leads to a PL fault(SCGCQ01924946) 
 - Aero3 Ring buffer prints indicate constant receipt of PMU messages from M0(SCGCQ01934152) 
 - Aero: ARM cache and MMU throwing exceptions during initialization(SCGCQ01936751) 
 - 0x6001 Fault while running IOs and doing cable pulls(SCGCQ01937141) 
 - Aero: backend PCIe: PDB PLL SSC should be enabled by default	(SCGCQ01940659) 
 - pl SFF-TA-1005: All Ux4 drives are not discovered in x8 or x16 HFC mode while hot-plugging(SCGCQ01877041) 
 - Ventura: Use full Slot Cap Physical Slot Number field info for PCIe SW attached device slot enumeration(SCGCQ01936123) 
 - Aero-3: Aero PL version not used(SCGCQ01942093) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01942781) 
 - Aero: Misc fixes for Eval board GPIO and PDB PCIe link config(SCGCQ01943862) 
 - PL SATL : TM aborted inquiry command is failed with check condition(SCGCQ01944673) 
 - CSW M0 Firmware version 649 ( protocol cycling fix)(SCGCQ01955494) 
 - Stray semicolon in rmcGetAvsoIndex(SCGCQ01957172) 
 - Coverity defect - uninitialized variable(SCGCQ01957686) 
 - Aero3: HW Workaround:PdbPll Requires the 25MHz Clock to Drive the PDB_REF_CLK_P Pad When Used Without an External Oscillator Source(SCGCQ01964380) 
 - Aero3: Miscellaneous MPI Device/Atlas SES allocation corner case defects(SCGCQ01991772) 
 - Aero A0: 2622 Fault is seen at first reset after server power cycle(SCGCQ02005819) 
 - BST fails on PH11 PA1 build(SCGCQ02006649) 
 - pl: Port Enable fault 0x7400 when connected to an Expander(SCGCQ02021097) 
 - pl: backend PCIe: need to configure equalizer presets in additional register(SCGCQ02006776) 
 - pl Ventura B0: PL fault 7221 observed on hot removing Capella II switch after boot to OS completes(SCGCQ02023831) 
 - pl Ventura B0: Incorrect number of vSES observed with one missing vSES when Capella II switch attached(SCGCQ02023850) 
 - pl: backend PCIe: device memory regions may overlap(SCGCQ02031472) 
 - MPI 2.6: Fix definition of SGLs in TOOLBOX_LANE_MARGINING_REQUEST(SCGCQ01896537) 
 - Aero/Ventura: Tip Int build is broken, SblSpicoStat redefined but not changed(SCGCQ01897804) 
 - pl: port enable timeout and discovery failure with multiple VPP device configurations(SCGCQ01870862) 
 - Ventura: PLI control requests may return incorrect status when backend PCIe support is disabled(SCGCQ01887433) 
 - Performance drop observed with expander attached topology in latest firmware.(SCGCQ02105245) 
 - PL: PL_INFO_PUIS_FLAGS violates the FW coding standard(SCGCQ01329829) 
 - Ventura: SCGCQ01800775 and SCGCQ01792449 both require a minimum initial firmwmare download size of 1.25K. MCTP will fail due to small payload size(SCGCQ01891838) 
 - Ventura RMC: AHR causes host to reboot.(SCGCQ01922333) 
 - (SATA Only) SCSI Write Same to SATA NCQ translation might block other NCQ IOs.(SCGCQ01931146) 
 - pl: backend PCIe: device not unblocked following rediscovery in reduced requirements mode(SCGCQ01932972) 
 - Wrong completion routine being called for aborted NVMe Encapsulated commands(SCGCQ01934165) 
 - Aero: backend PCIe: default link rate should be 16GT/s(SCGCQ01934903) 
 - Aero: CBB-Only in FLASH will fault due to external synchronous abort(SCGCQ01942768) 
 - Aero: FWUP fails after second reset after bad image update attempt(SCGCQ01944168) 
 - pl: NVMe: device not removed following NVMe init failure	(SCGCQ01918703) 
 - PL SATL : Host IOs may timeout after a sanitize command that completes with an error(SCGCQ01929016) 
 - ptrLinkRegs referenced before being initialized in pliMsg(SCGCQ01957141) 
 - Aero: PDB high priority interrupts have incorrect priority(SCGCQ01964422) 
 - 0x6004 Fault running TM only test(SCGCQ01858982) 
 - MR7.8: CTRL does not detect drives with SAS3.5CtrlFw_Ventura_Ph_9.0 08.250.09.00 and 10 as well(SCGCQ01914192) 
 - pl: backend PCIe: additional robustness for hot reset during SAS cycle case	(SCGCQ01922270) 
 - PL: 0xED22 fault when SFF-TA-1005 UBM Ex1 SAS drives are connected to HBA connector 1 and NVMe drives on Ex1 are connected to connector 2(SCGCQ01926357) 
 - pl UBM: Elrond Ex1 - Cannot see NVMe drive in slot 17 (offset = 16(SCGCQ01858852) 
 - Aero: backend PCIe: Atlas support is disabled by default	(SCGCQ01937069) 
 - If SBRReloadEn bit is set in Host Diagnostic register and AHR is issued from host, the AHR never completes.(SCGCQ01941995) 
 - Ventura : UBM change detection polling may not start in mixed backplane topology	(SCGCQ01943828) 
 - Aero 3: CSW M0 firmware change (ver 643(SCGCQ01945002) 
 - MPI 2.6: Fix definition of Signature0 field and PSOC download definition(SCGCQ01868634) 
 - pl UBM: Drives are not detected if they are reconnected back within polling interval(SCGCQ01918736) 
 - pl: backend PCIe: couple of issues with PCIe Switch Page 1(SCGCQ01934173) 
 - Aero3: CSW M0 firmware version 642(SCGCQ01938307) 
 - Aero3: OOB burst/idle times are not correct(SCGCQ01936080) 
 - D033 Fault observed when running IOs of 4MB IO size or greater on Aero controller(SCGCQ01951064) 
 - Overrunning array PmbusAddrScanVal in rmcPmbusSetVout(SCGCQ01957173) 
 - Coverity defects in IOP diag & print files(SCGCQ01957596) 
 - Coverity bugs in IOP Msg files(SCGCQ01957625) 
 - pl: NVMe: fix a few Coverity issues in NVMe files(SCGCQ01957671) 
 - pl: backend PCIe: EC63 fault	(SCGCQ01959012) 
 - Aero: backend PCIe: EF09 fault(SCGCQ01971067) 
 - Direct attached SAS/SATA drive discovery fails on customer specific Legacy backplanes.(SCGCQ01972659) 
 - Aero DDR: Citra boards getting WLA (0x4E1(SCGCQ01973347) 
 - Aero PL Library compile error(SCGCQ01973397) 
 - OEM drive carrier NVRAM details in drive is not getting cleared post nvram clear command(SCGCQ01974024) 
 - Ventura: BST fails due the MSIX Vectors being disabled(SCGCQ02007812) 
 - CONFIGURABLE_SECURE_PROGRAMMING_ENABLED defined in the wrong place(SCGCQ01938563) 
 - Aero A0: D065 Fault observed when running IOs of 8MB IO size or greater(SCGCQ01956203) 
 - Coverity found: Variable being used before initialization(SCGCQ01957143) 
 - Coverity Defects - uninitialized variables and variable overflow issues(SCGCQ01957676) 
 - Aero3: Firmware download fails if the SOC signature is not in the first DMA (loginfo 10411(SCGCQ01986363) 
 - Aero3: Sense Data buffers used for Atlas SES are not always freed(SCGCQ02008725) 
 - Aero-3: Board Image Config File has extra XML tags(SCGCQ02024703) 
 - Aero3: Goldenx seg faults when a partial component image is found in flash(SCGCQ02038817) 
 - SCSI VPD B2 inquiry LBPRZ field is not set correctly for NVMe drives.(SCGCQ02063217) 
 - Ventura B0: Locate LED cannot be turned off after diag reset with multi-VSES code(SCGCQ02053404) 
 - Fault 0x265D observed during port enable with direct attached SEP devices connected.(SCGCQ02057911) 
 - Multi-VSES: One of the drive connected to UBM x1 BP Enclosure may report on a different Enclosure(SCGCQ02061648) 
 - PL: SES direct attach initialization ring buffer print can access uninitialized pointer(SCGCQ02060017) 
 - Enclosure Information of particular OEM enclosure is displayed as 'Unknown' in UEFI HII(SCGCQ02062907) 
 - Aero-3: Board Image Config File has extra XML tags(SCGCQ02024703) 
 - Aero3: Goldenx seg faults when a partial component image is found in flash(SCGCQ02038817) 
 - SCSI VPD B2 inquiry LBPRZ field is not set correctly for NVMe drives.(SCGCQ02063217) 
 - Ventura B0: Locate LED cannot be turned off after diag reset with multi-VSES code(SCGCQ02053404) 
 - Fault 0x265D observed during port enable with direct attached SEP devices connected.(SCGCQ02057911) 
 - Multi-VSES: One of the drive connected to UBM x1 BP Enclosure may report on a different Enclosure(SCGCQ02061648) 
 - PL: SES direct attach initialization ring buffer print can access uninitialized pointer(SCGCQ02060017) 
 - Enclosure Information of particular OEM enclosure is displayed as 'Unknown' in UEFI HII(SCGCQ02062907) 
 - Enclosure Ids not shown in storcli output for the drives connected in DA SEP Backplane(SCGCQ02056095) 
 - UBM: With single connector to Ex1 backplane only every other slot's Locate LED can turn on(SCGCQ02066784) 
 - Ventura B0: SES Page A does not report DA NVMe drive details(SCGCQ02073743) 
 - UBM prints are enabled in Phase 11(SCGCQ02088503) 
 - Library might incorrectly set program/erase request bit when flash suspend feature enabled.(SCGCQ01873461) 
 - pl: SAS/SATA devices not discovered with partial backplane configuration(SCGCQ01870842) 
 - Ventura: NVMe I2C Backplane Detection fails on HBA connectors C2/C3 resulting in Slots not responding to LED updates(SCGCQ01886810) 
 - PL vSES: PCIe switch downstream virtual ports report SAS address of zero in SES page 0xA(SCGCQ01891238) 
 - Debug output contains multiple copies of the same information(SCGCQ01899293) 
 - PL: NVMe drives do not link up on non Ex4 backplane attached to an MR board(SCGCQ01878217) 
 - Ventura: Discovery may not complete, timeout on 94xx-8i HBA(SCGCQ01904851) 
 - Comments in plStates.c and plStates.h are wrong(SCGCQ01909770) 
 - pl: NVMe: E40A fault if WRPROTECT or RDPROTECT is nonzero(SCGCQ01892105) 
 - pl: backend PCIe: link fails to come up after a surprise down(SCGCQ01886012) 
 - pl: backend PCIe: unsupported completion timeout capabilities don't cause init failure(SCGCQ01906471) 
 - Ventura: IOC init may fail with Host Page Size Invalid LogInfo on backend PCIe disabled FW(SCGCQ01916779) 
 - Mismatch between data coming from Page2 and PageA in vSES(SCGCQ01859095) 
 - Ventura: OEM SW Enclosure Amber LED stays on after reboot(SCGCQ01898852) 
 - pl: backend PCIe: bug when setting up direct attached PL structures(SCGCQ01915755) 
 - Aero3: RMC changes necessary for complete boot.(SCGCQ01934925) 
 - Aero3: RMC workaround updates from Ventura(SCGCQ01936155) 
 - Aero: backend PCIe: PDB PLL is reinitialized when it's already locked(SCGCQ01937600) 
 - Aero3: Link not established interrupts are not being processed for all phys(SCGCQ01937617) 
 - Aero DDR: Updates to DDRlib for operation at 1600 MT/s(SCGCQ01940449) 
 - Aero3: Spurious CIB interrupt messages in ring buffer(SCGCQ01936912) 
 - Aero: backend PCIe: lane margining register accesses fail(SCGCQ01937082) 
 - Ventura README.doc in NVDATA folder mis-spelled "Mercator"(SCGCQ01764256) 
 - Build all fails for particular platform.(SCGCQ01876447) 
 - PL SATL : Sanitize operation may be completed with error even though drive did not report error(SCGCQ01937180) 
 - pl: backend PCIe: disable managed switch support(SCGCQ01940694) 
 - IO Unit Page 7 reports 0XFF for PCIeSpeed(SCGCQ01943129) 
 - The Aero3 build does not compile(SCGCQ01944855) 
 - pl: backend PCIe: potential race condition during switch downstream port link up(SCGCQ01837083) 
 - SmrZacHM/SmrZacHA not in reverse orders between the Big Endian and Little Endian(SCGCQ01848090) 
 - PL UBM : SAS, SATA drives in Elrond UBM backplane(SFF-TA-1005(SCGCQ01897599) 
 - Aero3: Initial Board Bringup Fixes(SCGCQ01932994) 
 -(SCGCQ01912662) 
 - pl: backend PCIe: switch attached NVMe device enumeration failed(SCGCQ01944149) 
 - SPILIB: Wrong status value used by spiiFlashWriteData(SCGCQ01909746) 
 - Aero: backend PCIe: NVMe devices in vendor specific JBOD may not link up(SCGCQ01944152) 
 - Aero A0: Diagnostic Resets cause Windows 2016 to blue screen with DPC Watchdog Violation error(SCGCQ01955501) 
 - Aero DDR: Updates to DDRlib for operation at 2666 MT/s(SCGCQ01955804) 
 - pl: backend PCIe: uninitialized variable when calling plPciDeviceManagerGetPortInfo(SCGCQ01957169) 
 - Logically dead code in CyBtldr_WriteApplication(SCGCQ01957184) 
 - pl: backend PCIe: potential dereference of null pointer(SCGCQ01957219) 
 - Aero: Duplicate slot numbers assigned for DA JBOD SAS/SATA drives(SCGCQ01957464) 
 - Coverity in IOP I2C Files(SCGCQ01957609) 
 - [Ventura] MCTP not freeing memory correctly in error path.(SCGCQ01960709) 
 - Aero3: M0 firmware update for Tx and SSC - Version 0x64F	(SCGCQ01961600) 
 - Link down after disable/enable with SAS IO Unit Page 1(SCGCQ01965094) 
 - pl: backend PCIe: 265D fault during 'pl pci enum' console command(SCGCQ01970745) 
 - Aero A0: 2668 Fault seen after running Scrutiny show-->scan-->show Commands in Windows(SCGCQ01970901) 
 - Use existing global buffers for config page access.(SCGCQ01972332) 
 - PL SATL : Read Error Counter log page fails with check condition on SSD drives(SCGCQ01982928) 
 - Aero: backend PCIe: link failure after surprise link down(SCGCQ01983569) 
 - Server serial number, Board Trace Number and controller Port number are not updating properly for Faulty and Predictive Fail smart drives.(SCGCQ01992276) 
 - Smart carrier backplane detection code sends I2c request continuously when there are no cables connected.(SCGCQ01996160) 
 - RMC: Remove Date and Time stamp from RMC debug output(SCGCQ02008611) 
 - Aero A0: 0xD30E fault is seen with 29 or more PCIe Devices configured in NVDATA(SCGCQ02017273) 
 - Aero DDR: ECC left in disabled state when multiple training iterations performed within DDR lib.(SCGCQ02017329) 
 - Aero: Fault 0xEC07 with PCIe attached devices with MegaRAID firmware(SCGCQ02018015) 
 - PL: Repeating Internal Task Managements Loginfo 0x31110E05(SCGCQ02021490) 
 - Ventura B0: vSES Devices Allocated number information reported incorrect on performing Switch add/remove multiple times(SCGCQ02029919) 
 - 0x600F fault during boot up with direct attached SATA devices(SCGCQ02031480) 
 - Ventura B0: sg_utils doesn't show either of the two vSES in Win2k16 when Ex1 and Ux4 with different BP types are connected(SCGCQ02035948) 
 - Ventura B0: Only one VSES shows up in Linux with latest PL FW on Start of the Day(SCGCQ02048217) 
 - Aero/Ventura: Using uninitialized value phyAddr.Low in iopSodPage45Validate(SCGCQ01957140) 
 - pl: debug print was not printing the appropriate entity(SCGCQ01957211) 
 - Coverity bugs in PL Diag Cmd file(SCGCQ01957687) 
 - Vendor unique Ventura based board: Fault 7220 while running vSES specific debug command(SCGCQ02029412) 
 - Aero3: Incorrect PCIe bus changed interrupt enabling and handling(SCGCQ01937573)
 - pl: backend PCIe: MSI-capable downstream port is programmed with invalid message data(SCGCQ01969980) 
 - PH11 PA StorCli - /c0 show not displaying Enclosure IDs after upgrading FW from 10.250.00.00 to 10.250.01.00(SCGCQ02024196) 
 - pl: backend PCIe: incorrect bus number may be assigned to a PCIe switch(SCGCQ02006700) 
 - VSES for PCIe Switch is not reported in Linux OS(SCGCQ02056673) 
 - Ventura B0: Drives mapped to incorrect Enclosure when CSW quads are attached to UBM backplane with different BPTypes(SCGCQ02056956) 
 - SPILIB: SFDP, when used with devices greater than 16MByte may fail erase	(SCGCQ01990650) 
 - Ventura: Fault 0x2805 encounted if one configures NVME and AutoPortEnable at the same time(SCGCQ01868375) 
 - Ventura MSS: VRef training failures on Marlin/Pocono boards.(SCGCQ01891340) 
 - Update the common header file to avoid compilation fail.(SCGCQ01886583) 
 - VenturaB0: SAS/SATA drives are not getting discovered with NVMe disabled firmware on both Crusader 9400-16iB0 and 9405W-16iB0(SCGCQ01876271) 
 - pl: NVMe: 6060 fault(SCGCQ01909264) 
 - Aero3: Serdes interrupt handlers are not compiled in for Aero(SCGCQ01868574) 
 - Ventura/Aero: Firmware Upload COMPLETE type fails if and SGE is too large(SCGCQ01903658) 
 - GOLDENX: Ventura image not accepted by GoldenX(SCGCQ01884228) 
 - pl UBM: NVMe drive behind Ex1 Elrond not discovered with PCIe switch in the topology(SCGCQ01932776) 
 - PL Fault 0x6001 occurred while running IOs + Task Management requests(SCGCQ01850755) 
 - pl: vSES reports incorrect product revision level in SES page 1(SCGCQ01877030) 
 - IO's can time-out after controller receives an unconfirmed response from a drive(SCGCQ01878174) 
 - pl dbg generate PL fault 4330(SCGCQ01881775) 
 - pl UBM SFF-TA-1005: Locate LED cannot be turned off after diag reset	(SCGCQ01884070) 
 - pl UBM: Ux4 drives not discovered in Polling Mode with HFCx16 and x8	(SCGCQ01896578) 
 - pl UBM: Locate LED cannot be turned off after diag reset for few drives on Ex1 Elrond(SCGCQ01905070) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01932394) 
 - Aero3 Fault 431b - unexpected interrupt(SCGCQ01934151) 
 - Aero3: Boot Algorithm indicates that sector 1 of OCM is invalid(SCGCQ01940518) 
 - Ventura: FW may fail FastPath IOs to NVMe devices with bad device handle error.(SCGCQ01942983) 
 - pl: Locate LED on SFF-TA-1005 Ux4 backplanes configured in x16 or x8 HFC emulation mode is not activated by storcli command(SCGCQ01866800) 
 - PL : SATA initialization may be completed even though there is a failed set feature command(SCGCQ01926787) 
 - pl: backend PCIe: parent switch port lookup may generate incorrect pointer(SCGCQ01883220) 
 - Ventura: NVMe devices attached to I2C backplane with no BP mgmt. device may not be detected by the HBA(SCGCQ01933117) 
 - Typo in Link Layer interrupt handler argument.(SCGCQ01955598) 
 - pl: NVMe: EC3D fault with invalid NVMe BAR(SCGCQ01955909) 
 - Logically dead code in SATA Initialization.(SCGCQ01957188) 
 - Coverity Fix: Assigning value, but the stored value is overwritten before it can be used in plCswPollTemperature(SCGCQ01957222) 
 - Coverity defects in controllerfw/iop/arm files(SCGCQ01957481) 
 - Ventura: OEM 24 drives PCIe Switch secondary VMD mode enable may not complete successfully(SCGCQ01957675) 
 - pl: backend PCIe: need to change default 64-bit backend address range(SCGCQ01960758) 
 - Aero: Add all valid pci device ID's to the supported devices structure(SCGCQ01952169) 
 - Aero A0: Secure boot key update fails with fault x3300 (SBLI Malloc Error(SCGCQ01955767) 
 - Aero: backend PCIe: new PCIe equalization transmitter presets(SCGCQ01955789) 
 - Coverity bug fix: Missing break for a case statement	(SCGCQ01957181) 
 - Aero-3: Sea Gen-1 PCIe workaround missing NVDATA change for Sea channel boards(SCGCQ01990467) 
 - Coverity bug fix: Uninitialized variable used in a debug print(SCGCQ01957164) 
 - (SATA Only) Firmware may fault (faultcode 0xD102) If task management is sent while SSU command is being translated to SATA drive.(SCGCQ01945583) 
 - Uninitialized variable being used for a debug print.(SCGCQ01957139) 
 - Using uninitialized value in iopDiagCmdCpldCfg(SCGCQ01957246) 
 - AERO: Aero eval board connected to SFF-TA-1005 UBM BP using connector 2 ONLY or 4 ONLY does not detect NVMe drives(SCGCQ01957303) 
 - Aero3: CLI Command iop pci reg fails with fault 0x265D(SCGCQ01962755) 
 - Aero DDR: Some evals exhibit WL Cycle Adjust failure (0x4E1(SCGCQ01963313) 
 - Direct attached SAS/SATA drive discovery fails on customer specific Legacy backplanes.(SCGCQ01963687) 
 - Sea A0: PCIe link speed reports as 2.5GT/s in Gen4 system(SCGCQ01982463) 
 - Aero-3: HW Workaround:Settings Change for Requested Tx Presets for PCIe Gen3 and Gen4 rates(SCGCQ02002663) 
 - Ventura: NVDATA Version incorrectly changed to 0x0C00 on Phase 11(SCGCQ02006676) 
 - Aero DDR: Memports configured incorrectly for Citra 8i cards(SCGCQ02020018) 
 - Fixing Coverity reported issues(SCGCQ01957677) 
 - Aero: backend PCIe: SRIS doesn't work(SCGCQ02017340) 
 - FW may encounter processor Data Abort exception error due to Null pointer access(SCGCQ02031148) 
 - Aero: backend PCIe: fix usage of uninitialized variable(SCGCQ01941171) 
 - Aero: Memory Model field is incorrect resulting in firmware update attempt in host booted code in secure mode(SCGCQ01943116) 
 - Aero3: Phy interrupt enables not set correctly(SCGCQ01943122) 
 - Ventura: Direct attached NVMe may not be detected in a mixed UBM backplane config(SCGCQ01951369) 
 - Active optical cables do not link reliably(SCGCQ01985176) 
 - Aero3: Port Enable with partially filled expander with managed switch Atlas causes Atlas's SES to be marked as missing(SCGCQ01986174) 
 - Aero: Locate LED does not work with latest Aero build using storCLI(SCGCQ01988013) 
 - AERO PL: Invalid DevHandle reported during MPI2_EVENT_PCIE_TOPOLOGY_CHANGE_LIST with 0 allocated MPI Devices(SCGCQ01990672) 
 - Aero: bit 3 of the MISC_CONTROL_1_OFF register at 0x8bc in DM core must remain set(SCGCQ01998396) 
 - pl: backend PCIe: 265D fault during 'pl pci dynmem' diag command	(SCGCQ01997992) 
 - pl: backend PCIe: Atlas switch becomes inaccessible after HBA fault(SCGCQ02007413) 
 - SPILIB: SPI Flash Registers get corrupted if NVSRAM is initialized after Flash(SCGCQ01993702) 
 - Aero: FW Fault 0x2801 On Running Heavy IO traffic with Host Diag Window Accesses(SCGCQ01993490) 
 - Aero: Firmware fault 0000265D seen with download signed bios image(SCGCQ02002617) 
 - Vent/Aero: RAM BIOS warning prints when there is no BIOS(SCGCQ02005335) 
 - 6004 Fault running IOs + Task Managements(SCGCQ02006628) 
 - Aero: Locate LED control on SFF-TA-1005 UBM not working with latest Aero build(SCGCQ02015769) 
 - pl: backend PCIe: EC59 fault on switch removal(SCGCQ02012578) 
 - Aero3/Ventura: "iop show cfg" sometimes shows bad information for large pages(SCGCQ01978775) 
 - pl: backend PCIe: ECC6 fault	(SCGCQ02007423) 
 - Aero: backend PCIe: ignore link bandwidth interrupts if link is not up(SCGCQ01991777) 
 - IO Unit Page 7 reports 0x04 for PCIe4 instead of 0x03(SCGCQ02017394)
 - Ventura B0: Overlapping slot IDs observed for vSES and PCIe Switch device(SCGCQ02023871) 
 - pl: Multi-vSES - pl creates a vSES with zero PHYs associated with it(SCGCQ02032492) 
 - Unchecked function call return value(SCGCQ01957478) 
 - [Ventura][PL] Applications trying to update NVMe device Firmware with Mode E fails.(SCGCQ01868163 port of SCGCQ01624790) 
 - Ventura: NVMe I2C Backplane Detection fails on HBA connectors C2/C3 resulting in Slots not responding to LED updates(SCGCQ01900839 port of SCGCQ01886810) 
 - pl: backend PCIe: unsupported completion timeout capabilities don't cause init failure(SCGCQ01907104 port of SCGCQ01906471) 
 - (vSES	(SCGCQ01961506 port of SCGCQ01955094) 
 - PL: Multipath: Failure to Enumerate Devices in Windows After Cable Pull/Push(SCGCQ01986252 port of SCGCQ01936773) 
 - PL: SAS Drives Take a Long Time to Link Up and Are Not Discovered Correctly(SCGCQ02000209 port of SCGCQ01973566) 
 - PL vSES: PCIe switch downstream virtual ports report SAS address of zero in SES page 0xA	(SCGCQ01898485 port of SCGCQ01891238) 
 - The Aero3 build does not compile	(SCGCQ01972941 port of SCGCQ01944855) 
 - MR 7.8 Package fails to spin-up multiple SAS SPL-2 Power Control capable drives(SCGCQ01969861 port of SCGCQ01963504) 
 - (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.(SCGCQ01961502 port of SCGCQ01955094) 
 - (NVME) Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.(SCGCQ01944365 port of SCGCQ01932728) 
 - Ventura: Use full Slot Cap Physical Slot Number field info for PCIe SW attached device slot enumeration(SCGCQ01941126 port of SCGCQ01936123) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01973959 port of SCGCQ01932394) 
 - Fault 0x26A8 While Connecting Fully Populated Enclosure to 9400-8e Controller(SCGCQ01967851 port of SCGCQ01944622) 
 - vSES SES Page 0Ah may report same SAS address for two elements during hot remove/add of NVMe devices	(SCGCQ01972964 port of SCGCQ01934145) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01973961 port of SCGCQ01942781) 
 - PL: SAS Drives Take a Long Time to Link Up and Are Not Discovered Correctly(SCGCQ01996142 port of SCGCQ01973566) 
 - Customer specific back plane not detected in the latest code phase(SCGCQ01972932 port of SCGCQ01961997) 
 - PL : Task management timeout is observed if the task management type is invalid(SCGCQ01979552 port of SCGCQ01969521) 
 - Ventura: OEM 24 drives PCIe Switch secondary VMD mode enable may not complete successfully(SCGCQ01960497 port of SCGCQ01957675) 
 - PL Spinup: Firmware Takes a Long Time to Grant Spinup to Some Drives/Phys(SCGCQ01996445 port of SCGCQ01963394) 
 - PDB data path parity error workaround(SCGCQ02018315 port of SCGCQ01733783) 
 - MCTP: MCTP over PCIe VDM Discovery can fail if Set EID and Port Enable collide(SCGCQ02032594 port of SCGCQ02029912) 
 - SATA: IO Timeouts with Read/Write and Non-Automated IO(SCGCQ02148184 port of SCGCQ01958700) 
 - Debug output contains multiple copies of the same information(SCGCQ01904001 port of SCGCQ01899293) 
 - PL: NVMe drives do not link up on non Ex4 backplane attached to an MR board	(SCGCQ01904802 port of SCGCQ01878217) 
 - Observed Data TLB exception when Sanitize with Block Erase service action is issued on a SATA SSD(SCGCQ01729541 port of SCGCQ01617939) 
 - Ventura: OEM SW Enclosure Amber LED stays on after reboot(SCGCQ01900846 port of SCGCQ01898852) 
 - pl: NVMe: E40A fault if WRPROTECT or RDPROTECT is nonzero(SCGCQ01903727 port of SCGCQ01892105) 
 - pl: backend PCIe: link fails to come up after a surprise down(SCGCQ01915671 port of SCGCQ01886012) 
 - pl: backend PCIe: bug when setting up direct attached PL structures(SCGCQ01917839 port of SCGCQ01915755) 
 - Ventura: Discovery may not complete, timeout on 94xx-8i HBA(SCGCQ01905232 port of SCGCQ01904851) 
 - MR 7.8 Package fails to spin-up multiple SAS SPL-2 Power Control capable drives(SCGCQ01969863 port of SCGCQ01963504) 
 - Ventura: SAS/SATA Drives behind passive backplane are not detected.(SCGCQ01971126 port of SCGCQ01969797) 
 - PL : Task management timeout is observed if the task management type is invalid(SCGCQ01979128 port of SCGCQ01969521) 
 - Ventura: SES Page 0Ah element descriptors of controller PHYs connected to a SMP target are marked as valid(SCGCQ01983423 port of SCGCQ01957185) 
 - Fault 0x26A8 While Connecting Fully Populated Enclosure to 9400-8e Controller(SCGCQ02018158 port of SCGCQ01944622) 
 - SIGNED FW fails to calculate the hash for the image correctly(SCGCQ02037366 port of SCGCQ02032484) 
 - Multi-VSES: Misc fixes and updates(SCGCQ02044279 port of SCGCQ02030141) 
 - 0x4308 Fault occurs when accessing various config pages before discovery has completed(SCGCQ02055399 port of SCGCQ02035973) 
 - Phase11 Ventura B0: Duplicate Help message entry in UART(SCGCQ02055328 port of SCGCQ02043820) 
 - Fix ISTWI code to work with PSOC download from storcli(SCGCQ02064215 port of SCGCQ01976251) 
 - SATA SMR: FIS Ported Zone commands execute in NCQ mode even when NCQ is disabled(SCGCQ02002016 port of SCGCQ01998969) 
 - VSES: Locate command to NVME drive in UBM backplane fails.(SCGCQ02060801 port of SCGCQ02053131) 
 - Ventura: Create NVDATA option to switch from single VSES to multi-VSES management for unmanaged PCIe Switch enclosures.(SCGCQ02065257 port of SCGCQ02035960) 
 - PL fault 0x6001 observed with heavy IOs to some NVME drives with Async events(SCGCQ02069488 port of SCGCQ02057418) 
 - MCTP: MCTP over PCIe VDM Discovery can fail if Set EID and Port Enable collide(SCGCQ02150203 port of SCGCQ02029912) 
 - NVMe Drive goes missing after running PD Pull Push Script in loop(SCGCQ02144448 port of SCGCQ02123786) 
 - Avoid releasing I2C bus when I2C operation(Read/Write(SCGCQ02162843 port of SCGCQ01721931) 
 - Performance drop observed with expander attached topology in latest firmware.(SCGCQ02141991 port of SCGCQ02105245) 
 - pl UBM: Firmware hit PL fault ed00 when pull/insert multiple drives(SCGCQ01964292 port of SCGCQ01957716) 
 - pl: Locate LED on SFF-TA-1005 Ux4 backplanes configured in x16 or x8 HFC emulation mode is not activated by storcli command(SCGCQ01873143 port of SCGCQ01866800) 
 - Fault 4311 when running repeated controller resets(SCGCQ01872931 port of SCGCQ01865882) 
 - pl UBM SFF-TA-1005: Locate LED cannot be turned off after diag reset	(SCGCQ01891218 port of SCGCQ01884070) 
 - pl UBM: Locate LED cannot be turned off after diag reset for few drives on Ex1 Elrond(SCGCQ01907168 port of SCGCQ01905070) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906462 port of SCGCQ01906013) 
 - pl SFF-TA-1005: All Ux4 drives are not discovered in x8 or x16 HFC mode while hot-plugging(SCGCQ01887446 port of SCGCQ01877041) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893314 port of SCGCQ01671177) 
 - PL:(SATA Only(SCGCQ01890861 port of SCGCQ01816525) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893315 port of SCGCQ01671177) 
 - vSES SES Page 0Ah may report same SAS address for two elements during hot remove/add of NVMe devices	(SCGCQ01934941 port of SCGCQ01934145) 
 - Mismatch between data coming from Page2 and PageA in vSES(SCGCQ01885749 port of SCGCQ01859095) 
 - PL: SSP Open Address frame uses wrong Destination SAS Address(SCGCQ01954754 port of SCGCQ01940668) 
 - vSES Doc: Update VSES document to reflect support for control/status element fields.(SCGCQ01984635 port of SCGCQ01961487) 
 - Data Abort Exception observed while running reboot test with a bad drive.(SCGCQ01987023 port of SCGCQ01985789) 
 - pl: backend PCIe: ED06 fault(SCGCQ01998064 port of SCGCQ01994860) 
 - pl VSES: Fault 0x4456 observed with un-managed switch connected to a Ventura HBA(SCGCQ02044275 port of SCGCQ02043944) 
 - 0x6004 Fault running TM only test(SCGCQ01876864 port of SCGCQ01858982) 
 - pl: vSES reports incorrect product revision level in SES page 1(SCGCQ01883332 port of SCGCQ01877030) 
 - MR7.8: CTRL does not detect drives with SAS3.5CtrlFw_Ventura_Ph_9.0 08.250.09.00 and 10 as well(SCGCQ01917864 port of SCGCQ01914192) 
 - PL UBM : SAS, SATA drives in Elrond UBM backplane(SFF-TA-1005(SCGCQ01911215 port of SCGCQ01897599) 
 - PL UBM : SAS, SATA drives in Elrond UBM backplane(SFF-TA-1005(SCGCQ01918898 port of SCGCQ01897599) 
 - pl: SAS/SATA devices not discovered with partial backplane configuration	(SCGCQ01872005 port of SCGCQ01870842) 
 - Ventura: Fault 0x2805 encounted if one configures NVME and AutoPortEnable at the same time(SCGCQ01896498 port of SCGCQ01868375) 
 - VenturaB0: SAS/SATA drives are not getting discovered with NVMe disabled firmware on both Crusader 9400-16iB0 and 9405W-16iB0(SCGCQ01878142 port of SCGCQ01876271) 
 - Ventura: IOC init may fail with Host Page Size Invalid LogInfo on backend PCIe disabled FW(SCGCQ01917857 port of SCGCQ01916779) 
 - Algorithm for setting user interrupt priority is incorrect.(SCGCQ01538676 port of SCGCQ01538100) 
 - pl: port enable timeout and discovery failure with multiple VPP device configurations(SCGCQ01872008 port of SCGCQ01870862) 
 - Ventura: PLI control requests may return incorrect status when backend PCIe support is disabled(SCGCQ01912231 port of SCGCQ01887433) 
 - OFU Failed on FW Download(SCGCQ01790850 port of SCGCQ01788985) 
 -	(SCGCQ01935009 port of SCGCQ01930597) 
 - (NVME(SCGCQ01944380 port of SCGCQ01932728) 
 - pl: backend PCIe: parent switch port lookup may generate incorrect pointer(SCGCQ01907148 port of SCGCQ01883220) 
 - pl: backend PCIe: link may fail to come up(SCGCQ01947876 port of SCGCQ01929279) 
 - Comments in plStates.c and plStates.h are wrong(SCGCQ01912136 port of SCGCQ01909770) 
 - pl UBM: Ux4 drives not discovered in Polling Mode with HFCx16 and x8(SCGCQ01906082 port of SCGCQ01896578) 
 - vSES : ENCLOSURE BYPASSED B bit set when Missing bit is set via Send diagnostics command(SCGCQ01962353 port of SCGCQ01960090) 
 - SATA: IO Timeouts with Read/Write and Non-Automated IO(SCGCQ01966772 port of SCGCQ01958700) 
 - pl: ED00 fault observed on crusader 16i when only Bottom part of Ux4 is connected to the core closest to PCIe slot(SCGCQ01955453 port of SCGCQ01938275) 
 - pl: VirtualSES do not show up in Windows when an SFF-TA-1005 UBM backplane with slot offset greater than 16 is connected to a Crusader 16i HBA(SCGCQ01955465 port of SCGCQ01944117) 
 - Hot plugging external SAS cables to Port 0 of 9400-16e HBA is not detected(SCGCQ01969792 port of SCGCQ01962567) 
 - Customer specific back plane not detected in the latest code phase(SCGCQ01972948 port of SCGCQ01961997) 
 - Enable the NVSRAM and general use of the 2nd SPI controller(SCGCQ01924847 port of SCGCQ01427395) 
 - PL Spinup: Firmware Takes a Long Time to Grant Spinup to Some Drives/Phys(SCGCQ01974250 port of SCGCQ01963394) 
 - Locate LED is non-functional for NVMe drives when we have a Switch attached enclosure as well as a Direct Attached enclosure(SCGCQ01985894 port of SCGCQ01957408) 
 - PL vSES: Number of slots for virtual SES is incorrect in StorCLI	(SCGCQ01993921 port of SCGCQ01991774) 
 - MPI 3.0: define for PLBP Signature is incorrect.(SCGCQ01933116 port of SCGCQ01933103) 
 - PL: SAS link up and drive discovery is delayed(SCGCQ02031184 port of SCGCQ02005349) 
 - pliTaskMgmt() returns ISTATUS_DEVICE_NOT_REGISTERED for a DA SEP(SCGCQ02031192 port of SCGCQ02022790) 
 - PH11 PA StorCli - /c0 show not displaying Enclosure IDs after upgrading FW from 10.250.00.00 to 10.250.01.00	(SCGCQ02038071 port of SCGCQ02024196)
	
EnhancementRequest:
 - SBLIB: Break out the pre-validate checks from each api call and add standalone pre-validate api check for aero(SCGCQ01924173) 
 - BST: Update bst scripts to support por request(SCGCQ02018624) 
 - Aero3: Modify "iop pci lnkspdr" so that it displays PCIe4 bus speed(SCGCQ01938727) 
 - Aero: backend PCIe: disable hot reset on link up	(SCGCQ01926246) 
 - Aero: Update SecureBoot Library and use new functions to verify all signatures in a FwDownloaded image are valid(SCGCQ01868691) 
 - Aero: Allow "Soft Secure" parts to boot even if EFUSE is not programmed(SCGCQ01868688) 
 - pl: backend PCIe: switch interrupt handler failure retries(SCGCQ01867808) 
 - Aero3: SpiLib: CR #06 Addition - Add an "exclusion" table to the SPI RDID logic(SCGCQ01599294) 
 - Aero-3: Create IT & PL/SCS Libs Release Scripts(SCGCQ01764972) 
 - Aero: Enhance user protection by eliminating writes to signature areas(SCGCQ01800775) 
 - Update CBB UART speed handling(SCGCQ01824074) 
 - sblib: Add sbliCompareKeys(SCGCQ01840951) 
 - SBLIB: Populate secure boot status structure	(SCGCQ01903769) 
 - Integrate MPI 2.6.7 release headers into Aero/Ventura code.(SCGCQ01892032) 
 - MPI 2.6: Add new IOCStatus code for "FAILURE"(SCGCQ01889947) 
 - Aero-3: Create 8 phy versions of NVDATA XSD files(SCGCQ01889946) 
 - pl: NVMe: Device Init Failure event(SCGCQ01857070) 
 - Add recognition and image creation for Sea.(SCGCQ01958225) 
 - pl: basic VSES task management support(SCGCQ02037364) 
 - MPI 2.6: Defines in header must be unique in first 32 characters.(SCGCQ01883411) 
 - Extend SATA Hinting to turn off after Port Enable is done(SCGCQ02046265) 
 - Update SAS Device Page 240 for smart carrier targets.(SCGCQ01949062) 
 - pl: NVMe: MAXCMD(SCGCQ01922181) 
 - Aero-3: Create production board NVDATA XSD(SCGCQ01732949) 
 - SBLIB: Modify key invalid routine to allow non-sequetial values(SCGCQ01924080) 
 - Aero: Port package.exe to Aero(SCGCQ01871556) 
 - Aero3: Change secure sign executable to HSM version(SCGCQ01926107) 
 - Aero-3: Review Aero PBAM changes	(SCGCQ01614626) 
 - Update Aero NVDATA files for Eval board(SCGCQ01380065) 
 - Aero: Update PSW and CSW M0 firmware images(SCGCQ01928209) 
 - Aero: Map CTL region for access to slave bypass registers.(SCGCQ01924811) 
 - pl: backend PCIe: DMDReportPCIe(SCGCQ01984296) 
 - Aero-3: Rename Images(SCGCQ01938306) 
 - MPI 2.6: Header file changes for MPI 2.6.7 release(SCGCQ01889371) 
 - Aero3: Port function to set power mode of SAS phys(SCGCQ01887443) 
 - Remove DMA_Q_MASK_STARVATION workaround for AERO	(SCGCQ01868871) 
 - NVMe Device Requirements document builder(SCGCQ01858472) 
 - Aero3: GoldenX-Add functionality to understand component headers and create golden images for Aero3(SCGCQ01766802) 
 - Aero3: Make serdes debug output selectable(SCGCQ01934991) 
 - Aero-3: Use Atlas SES as top-level switch enclosure's SEP and update vSES to account for managed switches(SCGCQ01917691) 
 - Timestamp changed to represent the system time(SCGCQ01883165) 
 - Aero: Dump UART input when EFUSE is enabled and FAULT if pciDeviceID is Invalid or Tampered(SCGCQ01931952) 
 - Pass mfg pages 40 and 41 parameters to CSW M0 firmware for serdes initialization (Aero only(SCGCQ01828140) 
 - Enable VSES support for Legacy Smart Carrier backplanes(SCGCQ01955258) 
 - Aero: Re-enable the automated public key hash update capability(SCGCQ01943086) 
 - pl: backend PCIe: allow usage of multiple memory regions for NVMe memory allocation(SCGCQ01840388) 
 - SES device identification in cascaded Expander backplane Topology(SCGCQ01991703) 
 - PCIe Reset functionality for NVMe drives for Slot Power Enable on UBM backplanes	(SCGCQ01989173) 
 - Aero3: Add internal request timing to MPI Devices (Atlas's MPI Device(SCGCQ02008728) 
 - Aero3: Measure code copy, hashing and decrypting times for IC validation	(SCGCQ02007875) 
 - pl: backend PCIe: assorted debug code(SCGCQ02033755) 
 - Aero3: Add internal request timing to MPI Devices (Atlas's MPI Device(SCGCQ02008728) 
 - Aero3: Measure code copy, hashing and decrypting times for IC validation(SCGCQ02007875) 
 - pl: backend PCIe: assorted debug code(SCGCQ02033755) 
 - PL support for authenticating Customer specific genuine drive carriers.(SCGCQ01904334) 
 - Aero: MPI spec IOC Page 1 - interrupt coalsecing change request (per reply queue group(SCGCQ01887289) 
 - Aero: backend PCIe: PCIe 4.0 lane margining interface(SCGCQ01439350) 
 - Aero: backend PCIe: retimer presence indication(SCGCQ01614679) 
 - Aero: Create Sea 9500 16e/8e Channel IT partial xmls	(SCGCQ02010096) 
 - Multi-VSES: Misc VSES optimization changes and clean up(SCGCQ02010087) 
 - Aero3: Firmware Download/Upload Reply Enhancements(SCGCQ01987206) 
 - Aero3: Update Flash Layout to Increase Firmware Area and Align Regions(SCGCQ01963275) 
 - Multi-vSES: vSES resource allocation and targets creation(SCGCQ01957613) 
 - Add ability to field upgrade PSOC on HBA board(SCGCQ01926234) 
 - Aero: Add verification of CBB signature when programming it without full image(SCGCQ01944998) 
 - Remove obsolete PCI front-end power management code(SCGCQ01940517) 
 - Added optional argument to enabled signImageX command to generate public key hash bin files.(SCGCQ01845116) 
 - Aero-3: Update IT release script & Create summary release notes(SCGCQ01937838) 
 - Aero3: Implement PMU message to notify M0 to init serdes parameters(SCGCQ01940678) 
 - Remove AERO_PORTING from IOP & Bootloader files(SCGCQ01915534) 
 - SPILIB: Modify initialization so that all devices uses 8 dummy bits for reads in dual and quad mode(SCGCQ01891968) 
 - Goldenx/Ventura: Add -s (signed bios image(SCGCQ01828984) 
 - Aero: pl: identify Atlas using vendor specific capability(SCGCQ01872108) 
 - Implemented changes to support remote signing using the HSM client application server for generating keys and signing automation.(SCGCQ01917757) 
 - MPB Page for Dual FW Download - Shenandoah program for OEM Hercules(SCGCQ02013978) 
 - NVData ManPage11 updated with fields to customize/enable/disable of the Host-Trace-Buffer (HTB(SCGCQ01996524) 
 - Add support for Dual MR FW Image boot(SCGCQ01995706) 
 - Add option to build Aero PL library for Shenandoah platform(SCGCQ01993973) 
 - Add support for host side MO PMU(SCGCQ01983429) 
 - Aero/Ventura: Reduce the memory requirement for large BIOS images(SCGCQ01980173) 
 - Aero/Ventura: Eliminate unused builds(SCGCQ01973189) 
 - Aero-3: Additional changes required for 8 phy board support(SCGCQ01969948) 
 - Aero-3: Create batch file to create images(SCGCQ01961839) 
 - Aero3: Support alternate refclk source PDB PLL ref clock (remove fault 0xECFD(SCGCQ01960866) 
 - Multi-vSES: Add UART cli cmd to dump vSES Device information(SCGCQ01957628) 
 - The VSES target command handling support in Multi-VSES environment(SCGCQ01957617) 
 - Add support for multi-VSES devices(SCGCQ01956217) 
 - Aero: Modify GoldenX and Firmware so that it requires BIOS to be signed(SCGCQ01947990) 
 - SPILIB: Create an example perl script to parse CSV logic analyzer file(SCGCQ01930607) 
 - Aero-3: Optimize I2C SCL settings for Aero(SCGCQ01926221) 
 - Aero-3: Add MPI Device error injection of dropping reply frame/descriptor and Adapter reset(SCGCQ01922368) 
 - pl: backend PCIe: update NVMe Device Requirements document builder(SCGCQ01922284) 
 - Build Process: Auto generate error code document and add to release zip(SCGCQ01921415) 
 - Aero-3: Use independent SMID pool for Atlas SES/MPI Device instead of LMID pool(SCGCQ01902320) 
 - Aero-3: Support PCI IEEE64bit chains for SCSI IOs to a managed switch's SES(SCGCQ01902128) 
 - Aero-3: Support Task Management for managed switch SES (Atlas SES(SCGCQ01889376) 
 - Create UART command to erase all of flash except MPB	(SCGCQ02020191) 
 - Update UBM info in Summary Release Notes	(SCGCQ02015861) 
 - Aero/Ventura: New cli command to indicate if POR is needed after a fw download(SCGCQ02010305) 
 - Create parsing tool for debug output and improve debug dump speed(SCGCQ01958152) 
 - RBD now decodes timestamps to UTC date and time(SCGCQ01906240) 
 - Aero: backend PCIe: preparation for usage of additional PCIe structure instances(SCGCQ01884135) 
 - Aero-3: Update temperature sensor code(SCGCQ01767270) 
 - SPILIB: Add support for JEDS216 with only 9 DWORDS of Basic Parameters(SCGCQ02015614) 
 - Aero: Eliminate TPH and MSIX workarounds meant for Ventura/Marlin(SCGCQ01876851) 
 - Aero DDR: Implement new test mode for Analog SE(SCGCQ01925998) 
 - Add workaround for SATA drive not complaint with ACS-3(SCGCQ01922154) 
 - Remove AERO_PORTING from PL_FEATURE_ACTIVE_CABLE_SUPPORT	(SCGCQ01915530) 
 - Aero: Incorporate EFUSE Key Update code from SBLIB and associated logic(SCGCQ01900830) 
 - pl: backend PCIe: update NVMe device requirements doc builder(SCGCQ01887377) 
 - pl: backend PCIe: enable firmware to handle vendor specific device(SCGCQ01884809) 
 - Customer specific build(SCGCQ01870343) 
 - MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1(SCGCQ01570730) 
 - MPI 2.6: Slot Numbering for x2/x4 wide connections to direct attached devices(SCGCQ01727225) 
 - Added Per-Device statistics/event collection(SCGCQ01883166) 
 - Aero-3: Improve backend MPI device error handling(SCGCQ01891231) 
 - Enable DCW blocks in slave bypass(SCGCQ01924163) 
 - NVDATA settings to override SCL low and high times(SCGCQ01915614) 
 - Aero: backend PCIe: review Gen 3.5 hardware workarounds for removal(SCGCQ01904852) 
 - Aero/Ventura: Add SPILIB test to verify SPI FLASH parts and libraries(SCGCQ01902039) 
 - Customer specific backplane and drive carrier discovery(SCGCQ01865592) 
 - Aero: backend PCIe: add support for Atlas synthetic mode pseudo endpoints(SCGCQ01862353) 
 - Aero RMC: Separate the Aero version of RMC from the Ventura version.(SCGCQ01853689) 
 - MPI 2.6: Header file changes for MPI 2.6.5 release(SCGCQ01853686) 
 - MR CBB changes to account for latest cbb changes.(SCGCQ01850067) 
 - Aero-3: Enable MPI Endpoint to Atlas(SCGCQ01736578) 
 - Ventura: Modify firmware download algorthm so that the SOC SBR signature is invalid until the image is checked(SCGCQ01792449) 
 - sblib: Add a library version(SCGCQ01882714) 
 - Port protocol cycling firmware workaround from Ventura to Aero(SCGCQ01859080) 
 - (NVMe(SCGCQ01627982) 
 - Aero-3: Add support for 8 phy chips(SCGCQ01789033) 
 - Aero: pass unhandled MPI toolbox messages to PL(SCGCQ01884405) 
 - Add Makefile target to build bootloader, for PL only builds(SCGCQ01997811) 
 - Customer specific Smart Drive Carrier NVRAM Update using VSES interface(SCGCQ01960319) 
 - To have separate transmit and receive I2C buffers for the back plane management module(SCGCQ01979141) 
 - Multi-vSES: Add support for populating Std Inquiry Resp data from NVDATA	(SCGCQ01957668) 
 - Support multi-host Atlas/multiple Atlases without exceptions	(SCGCQ01941252) 
 - PL Spinup: Add NVDATA Option to Wait SpinupDelay for SPL-2 Power Capable Drives(SCGCQ01916910) 
 - Improve NVSRAM timings(SCGCQ01698429) 
 - SPILIB: Check in enhanced CSV decoder(SCGCQ01940354) 
 - SPILIB: Add support for 32MB Macronix(SCGCQ01993348) 
 - Update Ventura Summary Release Notes	(SCGCQ01944825) 
 - Aero-3: Version Display(SCGCQ01982790) 
 - Smart Drive LED Support using VSES(SCGCQ01960305) 
 - Aero: backend PCIe: modify eval board NVDATA for minimum 16 NVMe devices(SCGCQ01985415) 
 - Master ER to check in MR related changes in CBB(SCGCQ01979367) 
 - Aero: Create 9500-16i Channel IT partial xml and update Channel XSDs(SCGCQ01978384) 
 - Atlas-3: SES Page Ah translation for Atlas SES(SCGCQ01902302) 
 - Remove Manufacturing Page 10 definitions	(SCGCQ01955443) 
 - Create blank partial XML for Aero Eval Board	(SCGCQ02002603) 
 - Aero3: managed switch SES support Sense Data to DDR and OCM memory(SCGCQ01961631) 
 - Aero3: Separate out DevH assignment of MPI Devices from PCIe Device DevHs for drives(SCGCQ02008733) 
 - Integrate latest MPI 2.6.8 header changes into Ventura.(SCGCQ01993555) 
 - MPI 2.6: Associated header changes for MPI 2.6.8 release.(SCGCQ01991840) 
 - SPILIB: Add backwards-compatible switch to disable RDID lookup (always use SFDP(SCGCQ01944845) 
 - Multi-vSES: Create and associate SES target for Direct attached Enclosure(SCGCQ01957615) 
 - Aero3: Set ready bit for Lane Margining for Host Side PCE(SCGCQ02008741) 
 - Aero/Ventura: Integrate latest SPILIB for Macronix Support(SCGCQ01994585) 
 - Remove SGPIO Double Pump Mode(SCGCQ02003955) 
 - Alphabetize IOP & PL CLI menus(SCGCQ01990521) 
 - Aero3: Add Toolbox Mem Move Restrictions	(SCGCQ02017429) 
 - Multi-vSES: Create vSES target for Direct Attached unmanaged PCIe SW Enclosure(SCGCQ02010081) 
 - pl: backend PCIe: debug code to dump unallocated memory trackers	(SCGCQ02031473) 
 - Updates to Aero XML files for package automation & update PCI Subsystem IDs(SCGCQ02015778) 
 - Multi-vSES: Create Direct attached Enclosures based on the Backplane type detected(SCGCQ01957610) 
 - MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021) 


Version  09.02.00.07
---------------
    BIOS            Firmware      UEFI Driver   
 9.17.00.00      09.00.07.00     09.00.01.00


IT PH9
fix Bug 175956 - [ThinkAgileVX] 430-8i and 430-8i dense hba queue depth mismatch
defects:
 - Aero: CBB linker warns of overlapped sections(SCGCQ01856283) 
 - pl: backend PCIe: EC59 fault on switch attached resource allocation failure(SCGCQ01840007) 
 - SCons: Doxygen Builder fails to keep track of dependencies(SCGCQ01326891) 
 - pl: backend PCIe: ECD2 fault(SCGCQ01856306)
 - Correct via file generation(SCGCQ01390690) 
 - Ventura: OEM ID66 PCIe Switch backplane Slots Status Amber LEDs stay blinking(SCGCQ01687610) 
 - pl: NVMe: ECF0 fault(SCGCQ01790929) 
 - Interrupts not handled in fault state if a high priority interrupt handler faults(SCGCQ01802508) 
 - MCTP: 0x265D fault occurs when running high MCTP PCIe VDM load with MCTP Discovery commands(SCGCQ01790303) 
 - Ventura B0: 0x5842 fault while running IOs and error injection tests(SCGCQ01780777) 
 - Ventura: In mixed topology, attn LED is non-functional for SAS/SATA drives on OEM backplane(SCGCQ01930666) 
 - MCTP: MCTP over PCIe VDM Discovery can fail if Set EID and Port Enable collide(SCGCQ02029912) 
 - SPI_LIBRARY: Eliminate the need for "zip" exectuable for all but the "release" builds(SCGCQ01830243) 
 - ISTWIToolBox command returns garbage data(SCGCQ01818214) 
 - Set discovery status error when unaddressable device is found(SCGCQ01750119) 
 - I2C Back Plane detection fails(SCGCQ01850098) 
 - pl: NVMe: E40E fault on NVMe shutdown of uninitialized NVMe device(SCGCQ01840036) 
 - Ventura: FW may fault 265Dh when attached to TA-1005 UBM Enclosures(SCGCQ01836829) 
 - Ventura: The SPI_LIBRARY release directory referenced in the PL auto build script doesn't exist(SCGCQ01832795) 
 - pl: backend PCIe: debug code for SCGCQ01845211(SCGCQ01858455) 
 - Error if PERL_DIR environment variable is set(SCGCQ01506708) 
 - PL vSES: PCIe switch downstream virtual ports report SAS address of zero in SES page 0xA(SCGCQ01891238) 
 - Ventura: NVMe I2C Backplane Detection fails on HBA connectors C2/C3 resulting in Slots not responding to LED updates(SCGCQ01886810) 
 - Performance drop observed with expander attached topology in latest firmware.(SCGCQ02105245) 
 - pl: NVMe: Solid State Media log page is missing(SCGCQ01807305) 
 - (SATA Only(SCGCQ01784132) 
 - PL SATL: SANITIZE Command failing for SATA SMR drives with ZNR bit set(SCGCQ01800567) 
 - (SATA Only(SCGCQ01732835) 
 - pl: NVMe: unexpected switch attached task management timeouts(SCGCQ01763332) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted (part 2(SCGCQ01727593) 
 - PL needs to check if we have a path to the end device before issuing a device reset to an NVMe drive as a part of TM(SCGCQ01826234) 
 - Incorrect Element status reported in SES Page 2 by vSES when connected to an expander(SCGCQ01822333) 
 - pl: backend PCIe: debug info for port enable subsystem integration(SCGCQ01817645) 
 - Ventura: OEM PCIe dual switch attached backplane slot status LED stays Amber on partial slots(SCGCQ01788989) 
 - C++ version of SPI library being included in MR SCS Lib releases	(SCGCQ01853784) 
 - pl: backend PCIe: ECC7 fault(SCGCQ01771244) 
 - pl: backend PCIe: EC3D fault(SCGCQ01835042) 
 - Ventura/Aero: ALADIN_PAGE45_INIT_FLAGS_STRUCT has too many bits (should be 32(SCGCQ01830026) 
 - Ventura: 265Dh Fault observed while accessing SFF-TA-1005 UBM backplane device(SCGCQ01826919) 
 - Ventura MSS: Multi-bit ECC, EFI SAS DRIVER issue seen when performed multi reboot stress from UEFI(SCGCQ01794025) 
 - Aero/Ventura: Remote Flash (rmtf.rom(SCGCQ01384845) 
 - 0x7211 Fault hit with more than one Elrond Ux4 midplanes attached(SCGCQ01850593) 
 - pl: SAS/SATA devices not discovered with partial backplane configuration	(SCGCQ01870842) 
 - pl: Handle partial PCIe Link configs for SFF TA 1005 UBM support(SCGCQ01857152) 
 - Ventura MSS: VRef training failures on Marlin/Pocono boards.(SCGCQ01891340) 
 - Debug output contains multiple copies of the same information(SCGCQ01899293) 
 - PL: NVMe drives do not link up on non Ex4 backplane attached to an MR board(SCGCQ01878217) 
 - Ventura: IOC init may fail with Host Page Size Invalid LogInfo on backend PCIe disabled FW(SCGCQ01916779) 
 - Ventura B0: Controller fault 0x7C41 observed during IO+System power cycle test(SCGCQ01790305) 
 - Ventura PL: New HW Workaround for 0x670A Fault(SCGCQ01841683) 
 - Fix to CSET SCGCQ01605489(SCGCQ01837880) 
 - pl: NVMe: Reference Temperature in the Temperature log page is incorrect(SCGCQ01807465) 
 - pl: NVMe: unexpected read/write IO failure with SkipCount error(SCGCQ01835109) 
 - pl: NVMe: TransferCount in the SCSI IO error reply message may be invalid(SCGCQ01830303) 
 - pl: backend PCIe: EC59 fault after failed switch discovery(SCGCQ01824028) 
 - Aero3 RMC: Fix reset of PSW M0 in RMC reset code	(SCGCQ01698264) 
 - Register type definition for Status register is incorrect.(SCGCQ01753001) 
 - IO not completing or being timed out if some cases when an unconfirmed response is received for an IO.(SCGCQ01718897) 
 - pl: backend PCIe: unsupported completion timeout capabilities don't cause init failure(SCGCQ01906471) 
 - Ventura: Fault 0x2805 encounted if one configures NVME and AutoPortEnable at the same time(SCGCQ01868375) 
 - VenturaB0: SAS/SATA drives are not getting discovered with NVMe disabled firmware on both Crusader 9400-16iB0 and 9405W-16iB0(SCGCQ01876271) 
 - pl: Fault 0xECAD while issuing controller reset in Ex1 configuration	(SCGCQ01859166) 
 - Ventura: UBM1005: Avoid PCIe reset request to FRU Port Descriptor unsupported PCIe drive types in DFC slots(SCGCQ01858809) 
 - MCTP: Fault 0x265D when packet with StartOfMsg is set and PktSeqCount is 1(SCGCQ01850721) 
 - Aero: backend PCIe: 265D fault with more than 1 Atlas switch	(SCGCQ01832995) 
 - SPI_LIBRARY: Add make.exe for systems without a gmake in their path(SCGCQ01830047) 
 - SPI flash write verification error when flash suspend feature is enabled.(SCGCQ01747153) 
 - pl: backend PCIe: PCIe port enable may time out(SCGCQ01849314) 
 - FW may fail to complete device discovery with certain TA-1005 UBM backplane configurations(SCGCQ01845203) 
 - vSES Listing multiple Array Device Elements for wide port devices (i.e., x2 or x4 NVMe or Wide SAS(SCGCQ01810677) 
 - Ventura B0: SAS and SATA drives may not get discovered on 9400-8e/16e(SCGCQ01851537) 
 - pl: NVMe: SCSI log page temperature may be incorrect in some cases(SCGCQ01804437) 
 - Ventura PL: 0x670A Fault During Destructive Domain Testing	(SCGCQ01831332) 
 - pl: port enable timeout and discovery failure with multiple VPP device configurations(SCGCQ01870862) 
 - pl: Fault 0xED22 seen on bootup(SCGCQ01868009) 
 - Ventura PL: Check in Revised Workaround for 0x5842 fault - Rx Dma Memory Overflow(SCGCQ01864843) 
 - Update the common header file to avoid compilation fail.(SCGCQ01886583) 
 - Ventura: OEM SW Enclosure Amber LED stays on after reboot(SCGCQ01898852) 
 - Ventura: Discovery may not complete, timeout on 94xx-8i HBA(SCGCQ01904851) 
 - pl: NVMe: E40A fault if WRPROTECT or RDPROTECT is nonzero(SCGCQ01892105) 
 - Mismatch between data coming from Page2 and PageA in vSES(SCGCQ01859095) 
 - Comments in plStates.c and plStates.h are wrong(SCGCQ01909770) 
 - pl: backend PCIe: parent switch port lookup may generate incorrect pointer(SCGCQ01883220) 
 - pl: backend PCIe: link fails to come up after a surprise down(SCGCQ01886012) 
 - pl: backend PCIe: bug when setting up direct attached PL structures(SCGCQ01915755) 
 - Aero: backend PCIe: buffer overflow during discovery of cascaded switches(SCGCQ01832807) 
 - Ventura Phase 9 build failure(SCGCQ01830200) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted	(SCGCQ01760627) 
 - Flash suspend feature is partially disabled based on initialization input option.(SCGCQ01750006) 
 - IOC_CTRL_OP_ALL_PHY_LOOPBACK operation is not working(SCGCQ01670396) 
 - Ventura/Aero: makespi.cmd has a system command not supported on some build systems(SCGCQ01829985) 
 - Ventura: PLI control requests may return incorrect status when backend PCIe support is disabled(SCGCQ01887433) 
 - pl: backend PCIe: potential for link degradation after multiple link downs(SCGCQ01848040 port of SCGCQ01793209) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01714280 port of SCGCQ01681441) 
 - IOC_CTRL_OP_ALL_PHY_LOOPBACK operation is not working(SCGCQ01792619 port of SCGCQ01670396) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted	(SCGCQ01794153 port of SCGCQ01760627) 
 - [Ventura][PL] Applications trying to update NVMe device Firmware with Mode E fails.(SCGCQ01849388 port of SCGCQ01624790) 
 - Ventura PL: Check in Revised Workaround for 0x5842 fault - Rx Dma Memory Overflow(SCGCQ01896576 port of SCGCQ01864843) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01851004 port of SCGCQ01765873) 
 - Ventura: Attaching multiple PCIe switches may cause IOP memory corruption(SCGCQ01875221 port of SCGCQ01853893) 
 - [ventura] PL Fault 0000ecc9 observed, while running doing drive Pull-Push with IO's in background(SCGCQ01817256 port of SCGCQ01804290) 
 - Heavy IO with low IO timeout test may result into an IO getting missed.(SCGCQ01840466 port of SCGCQ01631346) 
 - Fault 4311 when running repeated controller resets(SCGCQ01872930 port of SCGCQ01865882) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893313 port of SCGCQ01671177) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01817002 port of SCGCQ01792208) 
 - (SATA Only) SCSI Start Stop Unit command with power condition set to standby may fail for SATA drives.(SCGCQ01839608 port of SCGCQ01833392) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906461 port of SCGCQ01906013) 
 - Add workaround for SATA drive not complaint with ACS-3(SCGCQ01935094 port of SCGCQ01922154) 
 - (NVME) Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.(SCGCQ01944370 port of SCGCQ01932728) 
 - MCTP: Fault 0x265D when packet with StartOfMsg is set and PktSeqCount is 1(SCGCQ01966436 port of SCGCQ01850721) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01967409 port of SCGCQ01942781) 
 - (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.(SCGCQ01961501 port of SCGCQ01955094) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01967384 port of SCGCQ01932394) 
 - Fault 0x26A8 While Connecting Fully Populated Enclosure to 9400-8e Controller(SCGCQ01967850 port of SCGCQ01944622) 
 - PL : Task management timeout is observed if the task management type is invalid(SCGCQ01979551 port of SCGCQ01969521) 
 - Race condition can allow IOs over OOB to removed drive, with no host IOs, to not be cleaned up, and possibly leading to new drives not showing up(SCGCQ01807248 port of SCGCQ01400110) 
 - IOP: MCTP: Add NVDATA timeout parameter on message re-assembly(SCGCQ01836908 port of SCGCQ01223839) 
 - (SATA Only) SCSI Start Stop Unit command with power condition set to standby may fail for SATA drives.(SCGCQ01839609 port of SCGCQ01833392) 
 - Ventura: Attaching multiple PCIe switches may cause IOP memory corruption(SCGCQ01857051 port of SCGCQ01853893) 
 - The Aero3 build does not compile	(SCGCQ01972941 port of SCGCQ01944855) 
 - MR 7.8 Package fails to spin-up multiple SAS SPL-2 Power Control capable drives(SCGCQ01969861 port of SCGCQ01963504) 
 - (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.(SCGCQ01961502 port of SCGCQ01955094) 
 - (NVME) Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.(SCGCQ01944365 port of SCGCQ01932728) 
 - Ventura: Use full Slot Cap Physical Slot Number field info for PCIe SW attached device slot enumeration(SCGCQ01941126 port of SCGCQ01936123) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01973959 port of SCGCQ01932394) 
 - Fault 0x26A8 While Connecting Fully Populated Enclosure to 9400-8e Controller(SCGCQ01967851 port of SCGCQ01944622) 
 - vSES SES Page 0Ah may report same SAS address for two elements during hot remove/add of NVMe devices(SCGCQ01972964 port of SCGCQ01934145) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01973961 port of SCGCQ01942781) 
 - PL: SAS Drives Take a Long Time to Link Up and Are Not Discovered Correctly	(SCGCQ01996142 port of SCGCQ01973566) 
 - Customer specific back plane not detected in the latest code phase(SCGCQ01972932 port of SCGCQ01961997) 
 - PL : Task management timeout is observed if the task management type is invalid	(SCGCQ01979552 port of SCGCQ01969521) 
 - Ventura: OEM 24 drives PCIe Switch secondary VMD mode enable may not complete successfully(SCGCQ01960497 port of SCGCQ01957675) 
 - PL Spinup: Firmware Takes a Long Time to Grant Spinup to Some Drives/Phys(SCGCQ01996445 port of SCGCQ01963394) 
 - PDB data path parity error workaround(SCGCQ02018315 port of SCGCQ01733783) 
 - MCTP: MCTP over PCIe VDM Discovery can fail if Set EID and Port Enable collide(SCGCQ02032594 port of SCGCQ02029912) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01760767 port of SCGCQ01742362) 
 - IO not completing or being timed out if some cases when an unconfirmed response is received for an IO.(SCGCQ01767091 port of SCGCQ01718897) 
 - Race condition can allow IOs over OOB to removed drive, with no host IOs, to not be cleaned up, and possibly leading to new drives not showing up(SCGCQ01605489 port of SCGCQ01400110) 
 - Data NAK of large master TX packet can stop I2C out of band	(SCGCQ01766431 port of SCGCQ01713685) 
 - PL support for monitoring drive temperature during sanitize operation in progress(SCGCQ01753177 port of SCGCQ01600693) 
 - (SATA Only) Sense descriptor not filled properly for SCSI ATA Passthrough command failed by drive with SDA bit set(SCGCQ01788567 port of SCGCQ01784132) 
 - pl: NVMe: ECF0 fault	(SCGCQ01800735 port of SCGCQ01790929) 
 - Ventura: OEM PCIe dual switch attached backplane slot status LED stays Amber on partial slots(SCGCQ01826014 port of SCGCQ01788989) 
 - Data NAK of large master TX packet can stop I2C out of band	(SCGCQ01766430 port of SCGCQ01713685) 
 - Ventura: OEM ID66 PCIe Switch backplane Slots Status Amber LEDs stay blinking(SCGCQ01772655 port of SCGCQ01687610) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted (part 2	(SCGCQ01794972 port of SCGCQ01727593) 
 - Ventura: Locate operation to SAS/SATA drive slot may not turn on the status LED on OEM backplane	(SCGCQ01811106 port of SCGCQ01789068) 
 - pl: NVMe: unexpected read/write IO failure with SkipCount error(SCGCQ01838023 port of SCGCQ01835109) 
 - pl: Locate LED on SFF-TA-1005 Ux4 backplanes configured in x16 or x8 HFC emulation mode is not activated by storcli command(SCGCQ01873143 port of SCGCQ01866800) 
 - Fault 4311 when running repeated controller resets(SCGCQ01872931 port of SCGCQ01865882) 
 - pl UBM SFF-TA-1005: Locate LED cannot be turned off after diag reset	(SCGCQ01891218 port of SCGCQ01884070) 
 - pl UBM: Locate LED cannot be turned off after diag reset for few drives on Ex1 Elrond(SCGCQ01907168 port of SCGCQ01905070) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906462 port of SCGCQ01906013) 
 - Ventura MSS: Multi-bit ECC, EFI SAS DRIVER issue seen when performed multi reboot stress from UEFI(SCGCQ01822452 port of SCGCQ01794025) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01766712 port of SCGCQ01742362) 
 - pl: NVMe: Reference Temperature in the Temperature log page is incorrect	(SCGCQ01808970 port of SCGCQ01807465) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01817009 port of SCGCQ01792208) 
 - MCTP: 0x265D fault occurs when running high MCTP PCIe VDM load with MCTP Discovery commands(SCGCQ01833182 port of SCGCQ01790303) 
 - Ventura PL: New HW Workaround for 0x670A Fault(SCGCQ01842595 port of SCGCQ01841683) 
 - pl: NVMe: unexpected switch attached task management timeouts(SCGCQ01791046 port of SCGCQ01763332) 
 - pl: backend PCIe: debug info for port enable subsystem integration(SCGCQ01818293 port of SCGCQ01817645) 
 - pl SFF-TA-1005: All Ux4 drives are not discovered in x8 or x16 HFC mode while hot-plugging(SCGCQ01887446 port of SCGCQ01877041) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893314 port of SCGCQ01671177) 
 - Heavy IO with low IO timeout test may result into an IO getting missed.(SCGCQ01840468 port of SCGCQ01631346) 
 - pl: NVMe: TransferCount in the SCSI IO error reply message may be invalid(SCGCQ01831794 port of SCGCQ01830303) 
 - Interrupts not handled in fault state if a high priority interrupt handler faults(SCGCQ01803325 port of SCGCQ01802508) 
 - 0x6004 Fault running TM only test(SCGCQ01876864 port of SCGCQ01858982) 
 - pl: vSES reports incorrect product revision level in SES page 1(SCGCQ01883332 port of SCGCQ01877030) 
 - MR7.8: CTRL does not detect drives with SAS3.5CtrlFw_Ventura_Ph_9.0 08.250.09.00 and 10 as well(SCGCQ01917864 port of SCGCQ01914192) 
 - PL UBM : SAS, SATA drives in Elrond UBM backplane(SFF-TA-1005(SCGCQ01911215 port of SCGCQ01897599) 
 - PL UBM : SAS, SATA drives in Elrond UBM backplane(SFF-TA-1005(SCGCQ01918898 port of SCGCQ01897599) 
 - Incorrect Element status reported in SES Page 2 by vSES when connected to an expander(SCGCQ01824998 port of SCGCQ01822333) 
 - PL needs to check if we have a path to the end device before issuing a device reset to an NVMe drive as a part of TM	(SCGCQ01826239 port of SCGCQ01826234) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01851007 port of SCGCQ01765873) 
 - [ventura] PL Fault 0000ecc9 observed, while running doing drive Pull-Push with IO's in background(SCGCQ01829989 port of SCGCQ01804290) 
 - pl UBM: Ux4 drives not discovered in Polling Mode with HFCx16 and x8	(SCGCQ01906082 port of SCGCQ01896578) 
 - pl: NVMe: SCSI log page temperature may be incorrect in some cases(SCGCQ01807316 port of SCGCQ01804437) 

EnhancementRequest:
 - Aero/Ventura: Create a build environment in the SPI_LIBRARY component(SCGCQ01819132) 
 - SCONS: Add Doxygen builder(SCGCQ01282782) 
 - Add source utilities	(SCGCQ01287449) 
 - Add debug string builders(SCGCQ01288927) 
 - SCons armv5 build server support	(SCGCQ01393685) 
 - Aero release support(SCGCQ01392706) 
 - SBLIB API functions need to do a sbliInitialize check(SCGCQ01861986) 
 - BST: Update bst scripts to support por request(SCGCQ02018624) 
 - Aero3: Integrate sasparser 11.02.00.00 into Aero build process(SCGCQ01851153) 
 - Aero-3: Add securesign to build process of full firmware image(SCGCQ01509968) 
 - Create Secure Boot Library(SCGCQ01478545) 
 - Add multithreaded elftobin(SCGCQ01572366) 
 - Remove mpi3_type.h from sbliApi.h	(SCGCQ01824159) 
 - Added functionality to secureSign.exe to stamp the signed FW Image with the PublicKeyList ID for tracking purposes.(SCGCQ01839760) 
 - sblib: IT Integration issues	(SCGCQ01857288) 
 - Aero: Add checking of secure main firmware (APP(SCGCQ01856978) 
 - SFF-TA-1005 UBM: Additional error handling support(SCGCQ01833053) 
 - Support merging of multilple define sections from multiple yaml files.(SCGCQ01351246) 
 - Add site license warning suppression	(SCGCQ01416563) 
 - Improve SCons dependency tools(SCGCQ01496996) 
 - Suppress license warnings(SCGCQ01641063) 
 - Implemented secureSign.exe CLI tool for automating FW signing process with signImageX(SCGCQ01799918) 
 - Keep inc directory local(SCGCQ01878222) 
 - Secure Boot image validation support(SCGCQ01478605) 
 - RMC: Force RMC to be built when main firmware images are built.(SCGCQ01807469) 
 - Ventura: Support for IOP direct access of ISTWI devices that are not specified in Man page 43(SCGCQ01750098) 
 - Enable SRIS to enable external NVMe capability(SCGCQ01807622) 
 - Add nvmeProtocol.h to MR PL release(SCGCQ01837309) 
 - NVMe: SFF-TA-1005 UBM PCIe Power Management support(SCGCQ01763350) 
 - pl: backend PCIe: ordered event handling for cascaded switches(SCGCQ01850742) 
 - Ventura: Improve verbose "pl mids" output(SCGCQ01863333) 
 - Add ARMv5 tool support(SCGCQ01344659) 
 - Improve Scons error handling	(SCGCQ01390029) 
 - Avenger: Change symbol build tool from external executable to internal python(SCGCQ01494130) 
 - Add make support	(SCGCQ01572146) 
 - Add via file source utilities(SCGCQ01291806) 
 - Improvements to Avenger build tools(SCGCQ01400119) 
 - Disable efuse updates(SCGCQ01830292) 
 - Extend SATA Hinting to turn off after Port Enable is done(SCGCQ02046265) 
 - aviSerdesGenericSpicoEccCheck((SCGCQ01807158) 
 - ComboSerdes: add API function to wait for SAS to PCIe transition to complete(SCGCQ01928060) 
 - Aero-3: New CSW / 16FF Serdes(SCGCQ01448312) 
 - SPI Flash Suspend/Resume feature support.(SCGCQ01735536) 
 - Add support for mr build to get bin using fromelf(SCGCQ01501207) 
 - Remove inc flags from the via file(SCGCQ01521426) 
 - Update Channel board NVDATA to include info for automation of HwBoardImageConfig creation(SCGCQ01803280) 
 - Update temperature sensor output	(SCGCQ01616949) 
 - Aero-3: Check Completor Posted Writes and Requestor Posted Writes bits in FPE Status 1 in determining Idle(SCGCQ01824153) 
 - Aero: Get FPGA to scheduling loop(SCGCQ01766800) 
 - Ventura: Eliminate need for IOPRINT_X_DEFAULT_08X(SCGCQ01488980) 
 - Ventura: Integrate SPI_LIBRARY project build system to the IT firmware(SCGCQ01680530) 
 - Aero3: Create Aero3 non-FPGA nvdata(SCGCQ01764985) 
 - Aero: backend PCIe: Downstream Port Containment(SCGCQ01828062) 
 - SPI_LIBRARY: Modify the component so that the basetypes file is optional(SCGCQ01827876) 
 - ISTWIToolBox command handling using parameters passed in from the host(SCGCQ01824007) 
 - pl: backend PCIe: change the Predetermined Number of Lanes setting to 1(SCGCQ01784774) 
 - SFF-TA-1005 UBM: Backplane change detection polling mode support(SCGCQ01727552) 
 - Aero: backend PCIe: root port 16GT/s lane equalization(SCGCQ01614673) 
 - Aero: backend PCIe: Gen4 hardware and device init(SCGCQ01380060) 
 - SFF-TA-1005 UBM: UBM HFC RefClk control, DFC drive presence detection and Port Reset control(SCGCQ01750204) 
 - pl: backend PCIe: runtime control of Atlas switch support (part 2(SCGCQ01853888) 
 - pl: Aero: remove Atlas 32-bit address space workaround(SCGCQ01763386) 
 - SFF-TA-1005 UBM: UBM backplane CHANGE_DET# Signal Interrupt support(SCGCQ01727480) 
 - Remote Flash utility for Avenger.(SCGCQ01618931) 
 - Implement Secure Boot Library changes needed for MegaRAID(SCGCQ01797407) 
 - Aero: backend PCIe: support for Atlas physical slot numbering(SCGCQ01845211) 
 - Added pmuMsg.h file to project.(SCGCQ01832975) 
 - Ventura: Make SGPIO as vSES default backplane mgmt. method(SCGCQ01792989) 
 - Aero DDR: Software based Read Fifo(SCGCQ01767237) 
 - Aero-3: Update Copyright to Broadcom	(SCGCQ01732998) 
 - PL SATL: RC BASIS Handling for SCSI Read Capacity 16 for SMR SATA drives	(SCGCQ01615537) 
 - Aero-3: Add support for MCTP Discovered Flag clearing due to BDF change(SCGCQ01533535) 
 - Aero-3: Update CCR headers to reflect latest register map.(SCGCQ01826405) 
 - Aero: backend PCIe: basic Atlas validation board bringup	(SCGCQ01794264) 
 - Aero DDR: PHY based Gate Training(SCGCQ01405423) 
 - Added optional argument to enabled signImageX command to generate public key hash bin files.(SCGCQ01845116) 
 - sblib: Add release component support	(SCGCQ01867576) 
 - sblib: Improve key update test cases	(SCGCQ01830308) 
 - Aero-3: Create Temporary IT Release Script(SCGCQ01837898) 
 - Aero: Update CSW M0 firmware(SCGCQ01828153) 
 - pl: NVMe: tweak NVMe temperature threshold configuration(SCGCQ01808996) 
 - Misc changes for CHANGE_DET# Signal Interrupt and drive hot-plug support(SCGCQ01797168) 
 - Aero: pl: protocol cycle detector support for Aero(SCGCQ01794128) 
 - I2C BUS busy when BMC try to access other devices on the bus with MCTP disabled.(SCGCQ01697892) 
 - To do dynamic configuration of the PCIe link from the backplane configuration data(SCGCQ01507511) 
 - Aero DDR: Software based Write Leveling Cycle Adjustment(SCGCQ01405431) 
 - Aero-3: IOP: Host PCI Express 4 x8 interface	(SCGCQ01380006) 
 - pl: backend PCIe: Atlas base mode duplicate serial number handling(SCGCQ01819242) 
 - Aero DDR: Clean up Aero DDR lib(SCGCQ01789017) 
 - pl: backend PCIe: immediate retry of firmware initiated PCIe transactions during link recovery(SCGCQ01841059) 
 - NVMe Devices added to Inventory and support for NVME AEN	(SCGCQ01607921) 
 - sblib: Efuse update support(SCGCQ01764966) 
 - SBLIB: Add API's that allow the user to check all signatures in a component	(SCGCQ01870043) 
 - Remove mpi dependency from sblib api	(SCGCQ01864752) 
 - sblib: Integrate sblib with Aero IT(SCGCQ01865928) 
 - sblib: Increase compatiblity by relocating/renaming global variables	(SCGCQ01882599) 
 - pl: backend PCIe: add switch count to Manufacturing Page 9(SCGCQ01851624) 
 - Add debug prints and dump for new serdes(SCGCQ01831104) 
 - RMC: Remove old RMC binary from version control(SCGCQ01817562) 
 - Initial version of PSOC programming code(SCGCQ01794157) 
 - SFF-TA-1005 UBM - FRU device detection and FRU Record processing support(SCGCQ01727443) 
 - Add support for configuring PCA9555 IO expander for OEM VPP compatible backplane.(SCGCQ01807461) 
 - SFF-TA-1005 UBM: Drive Slot status LED control(SCGCQ01727586) 
 - Ventura: Modify PL to only allocate required config page buffer size(SCGCQ01817424) 
 - SFF-TA-1005 UBM: UBM Controller enumeration support(SCGCQ01727463) 
 - Ventura/Aero: Implement Extended Mfg Page 45 - Aladin Config Page - Implement Aladin Init(SCGCQ01680543) 
 - PL: Add Nvdata Option to Disable SPL-2 Power Capable Spinup(SCGCQ01823993)

  

Version  08.01.05.00-1
---------------
    BIOS            Firmware      UEFI Driver      
  9.15.00.00        08.00.03.00    8.00.00.00     

IT Phase 8 (new)
 
Defects:
 - Marlin RMC: Fix checking of cores in reset during ChipReset sequence.(SCGCQ01197528) 
 - ((SATA Only) Security Protocol In command complete without data transfer for allocation length not a multiple of 512.(SCGCQ01275335) 
 - Charlotte DVT (3616) - Fails PCI Express Compliance Configuration Test.(SCGCQ01320438) 
 - Ventura: MCTP PCIe VDM: Discovered flag is set in Endpoint Discovery command.(SCGCQ01486410) 
 - The soft FIFO size calculations don't take into account the data descriptor sf threshold.(SCGCQ01488633) 
 - Controller is not detecting in the storelib, after changing the mode from "set mode oob" command.(SCGCQ01494018) 
 - PL: Update internal macros.(SCGCQ01503214) 
 - Ventura build failure.(SCGCQ01505238) 
 - RMC: Prevent leakage of P credits during SoftReset(SCGCQ01507699) 
 - Fixed IOP coverity defect for intruder.(SCGCQ01508917) 
 - PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB.(SCGCQ01509770) 
 - Fault 0xC00C is occurred in random read running test.(SCGCQ01511237) 
 - pl: backend PCIe: 4311 fault with NVMe enabled.(SCGCQ01514521) 
 - Ventura hardware does not like the IOP enable method used here.(SCGCQ01514880) 
 - (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices.(SCGCQ01516277) 
 - pl: backend PCIe: non-NVMe endpoint not cleaned up on removal.(SCGCQ01516968) 
 - Fault(0x4330) is occurred during checking MPI2_IOCSTATUS_TARGET_TOO_MUCH_WRITE_DATA.(SCGCQ01518952) 
 - Fixing the issues during bringup of the universal backplane.(SCGCQ01522148) 
 - pl: backend PCIe: switch attached discovery takes too long.(SCGCQ01522343) 
 - pl: backend PCIe: 4311 fault with NVMe enabled (part 2).(SCGCQ01523531) 
 - Ventura: Add early notification to new I2C-DMA-Less algorithm in case hardware doesn't interrupt.(SCGCQ01524953) 
 - pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset.(SCGCQ01526236) 
 - Handling of host PCI BAR programming changes after port enable.(SCGCQ01530295) 
 - pl: NVMe: EC0D fault.(SCGCQ01530402) 
 - PL Fault 0000ecdd LR 01403837 during initial discovery.(SCGCQ01531770) 
 - To fix issues for back plane configuration validation and LED control for the UBM backplane.(SCGCQ01533852) 
 - Ventura: Some toplevel PCE interrupts have a priority that is too low.(SCGCQ01534773) 
 - pl: backend PCIe: 4311 fault (part 3).(SCGCQ01537791) 
 - pl: NVMe: unexpected task management halt when a device goes missing.(SCGCQ01538012) 
 - Fault 5850 occurred in random read test with Task management.(SCGCQ01538680) 
 - pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment.(SCGCQ01540226) 
 - Ventura B0: FW blocking SATA devices behind enclosures.(SCGCQ01552996) 
 - (SATA Only) Incorrect sense data may be returned when a NCQ Queued Error Log data page is returned.(SCGCQ01553853) 
 - pl: backend PCIe: tweaks to the backend PCIe link configurations API.(SCGCQ01556422) 
 - IT/PL FW Compliance to use of NO FLUSH bit in START STOP UNIT based on SAT3.(SCGCQ01563244) 
 - pl: verify that RAID context Timeout value is nonzero before adding a timer.(SCGCQ01564757) 
 - pl: NVMe: admin command Abort Task reset type.(SCGCQ01565972) 
 - pl: backend PCIe: 'pl pci swregs' debug command is broken.(SCGCQ01566859) 
 - Ventura B0 Phase 7 - Fault 2805 hit after enabling auto port feature.(SCGCQ01572362) 
 - To fix the LED issue, VPP data and moving to change detect poll state.(SCGCQ01576165) 
 - (SATA Only.(SCGCQ01577907) 
 - pl: vSES - Enable Swap bit support in SES page 2.(SCGCQ01590780) 
 - Ventura B0: Windows server 2016 OS may not detect all drives on OEM backplane in a mixed mode config(SCGCQ01592762) 
 - Several firmware build utilities don't compile anymore.(SCGCQ01594270) 
 - Observed Exception during Test run: IocStatus: Insufficient Resources (0006).(SCGCQ01600177) 
 - Device block and unblock messages observed for the existing connected NVMe drives when new NVMe drive is inserted.(SCGCQ01615532) 
 - Firmware Build Utilities: AddImage utility gets flagged and removed by anti-virus software.(SCGCQ01619096) 
 - Ventura: Build time duration started displaying negative time.(SCGCQ01630393) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01639482) 
 - Missing code to handle no response in MCTP transmit buffer and send busy retry(SCGCQ01676010) 
 - Aero RMC: Fix non-secure boot mode(SCGCQ01683135) 
 - pl: NVMe: unnecessary SATA cleanup attempted during NVMe TM.(SCGCQ01683245) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01684262) 
 - Mercator: AHR failure when using workaround for SCGCQ01318807(SCGCQ01685001) 
 - SGPIO SCLK Glitch and Low upon coming out of reset(SCGCQ01697481) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted (part 2).(SCGCQ01727593) 
 - pl: backend PCIe: notification events for switches with no devices attached(SCGCQ01729831) 
 - Ventura: CFGI fails if the largest MPI defined config page is not included(SCGCQ01737603) 
 - Aero build fails.(SCGCQ01748072) 
 - pl: NVMe: unexpected switch attached task management timeouts(SCGCQ01763332) 
 - Ventura B0: 0x5842 fault while running IOs and error injection tests(SCGCQ01780777) 
 - (SATA Only)Sense descriptor not filled properly for SCSI ATA Passthrough command failed by drive with SDA bit set.(SCGCQ01784132) 
 - Ventura B0: Controller fault 0x7C41 observed during IO+System power cycle test(SCGCQ01790305) 
 - pl: NVMe: ECF0 fault(SCGCQ01790929) 
 - PL SATL: SANITIZE Command failing for SATA SMR drives with ZNR bit set(SCGCQ01800567) 
 - pl: NVMe: SCSI log page temperature may be incorrect in some cases(SCGCQ01804437) 
 - pl: NVMe: Reference Temperature in the Temperature log page is incorrect(SCGCQ01807465) 
 - pl: backend PCIe: debug info for port enable subsystem integration(SCGCQ01817645) 
 - Incorrect Element status reported in SES Page 2 by vSES when connected to an expander(SCGCQ01822333) 
 - PL needs to check if we have a path to the end device before issuing a device reset to an NVMe drive as a part of TM(SCGCQ01826234) 
 - pl: NVMe: TransferCount in the SCSI IO error reply message may be invalid(SCGCQ01830303) 
 - pl: NVMe: unexpected read/write IO failure with SkipCount error(SCGCQ01835109) 
 - Fix to CSET SCGCQ01605489(SCGCQ01837880) 
 - Ventura PL: New HW Workaround for 0x670A Fault(SCGCQ01841683) 
 - RMC: Add full interrupt disable to SBR Reload code(SCGCQ01212765) 
 - SCSI format command send to NVMe drives fails with CMPLIST flag set in addition to FMTDATA flag(SCGCQ01229799) 
 - SPI reset delay needs to be enabled in B0 revs(SCGCQ01241767) 
 - pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01487423) 
 - pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01518343) 
 - To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01542497) 
 - PL: Implemented HW workaround to solve 6G SATA link fail problem(SCGCQ01554661) 
 - Ventura: If firmware download is done in small pieces, firmware download fails with logInfo 30010402(SCGCQ01558208) 
 - pl: backend PCIe: EC52 fault(SCGCQ01565749) 
 - Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01574224) 
 - Remove and Truncate command handler: IO was not failed with check condition(SCGCQ01594602) 
 - Aero-3: make aero doesn't compile(SCGCQ01614670) 
 -(SCGCQ01615484) 
 - Aero3: Signed CBB hangs(SCGCQ01624857) 
 - Aero DDR: DDR fails after issuing MSS reset(SCGCQ01685637) 
 - Ventura: OEM ID66 PCIe Switch backplane Slots Status Amber LEDs stay blinking(SCGCQ01687610) 
 - RMC: Need to use AHB path to write to Reset Status Register(SCGCQ01718319) 
 - Ventura: OEM PCIe dual switch attached backplane slot status LED stays Amber on partial slots(SCGCQ01788989) 
 - MCTP: 0x265D fault occurs when running high MCTP PCIe VDM load with MCTP Discovery commands(SCGCQ01790303) 
 - Update combo serdes library version.(SCGCQ01791178) 
 - Interrupts not handled in fault state if a high priority interrupt handler faults(SCGCQ01802508) 
 - Ventura PL: 0x670A Fault During Destructive Domain Testing(SCGCQ01831332) 
 - Ventura B0: Slot status updates to certain slot on NVMe backplane may not update the LED status(SCGCQ01573106) 
 - MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN	  (SCGCQ01631826) 
 - (SATA Only)When ATA command fails with sense data available bit set, Data frame may not be released.(SCGCQ01732835) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01742362) 
 - Fault C010 encountered when running IO to 9405W-16e in Target Mode(SCGCQ01368001) 
 - (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct.(SCGCQ01638248) 
 - Ventura: In mixed topology, attn LED is non-functional for SAS/SATA drives on OEM backplane(SCGCQ01930666) 
 - PDB data path parity error workaround(SCGCQ01733783) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01765873) 
 - Ventura: Locate operation to SAS/SATA drive slot may not turn on the status LED on OEM backplane(SCGCQ01789068) 
 - Negotiated Link Speed for the vSES target is displayed as 'Unknown'.(SCGCQ01606720) 
 - Not all NVMe drives were discovered after server cold or warm boot(SCGCQ01664963) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01671177) 
 - VPD is not shown by lspci(SCGCQ01687750) 
 - Not all NVMe drives discovered as part of hot plug operation(SCGCQ01697329)
- PL: Error LED stays on when drive is pulled out when using unusual slot mapping and drive presence check(SCGCQ01222315 port of SCGCQ01157331) 
 - 9305-16i - Activity LED signal is not asserted for port 2 and 3.(SCGCQ01382008 port of SCGCQ01318981) 
 -(SCGCQ01431063 port of SCGCQ01415060) 
 - SATA ONLY: VPD page 0xB2 LBPU bit not set correctly.(SCGCQ01511589 port of SCGCQ01374552 port of ) 
 - IOP: Differentiate between L2 correctable and uncorrectable faults(SCGCQ01512630 port of SCGCQ00929810) 
 - IOP: Faulting for correctable L2 parity errors(SCGCQ01512800 port of SCGCQ00934325) 
 - PL: SAS3 PHASE12 RAID creation failing with SATA drives.(SCGCQ01512834 port of SCGCQ00998155) 
 - Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01513298 port of SCGCQ00856085) 
 - Fault State Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01514262 port of SCGCQ00856085) 
 - IOP: Faulting for L2 Cache Correctable Errors(SCGCQ01514707 port of SCGCQ01264714) 
 - (SATA Only)Signature FIS not validated for Expander attached SATA drives(SCGCQ01514869 port of SCGCQ00852290) 
 - STANDBY_Z Bit Not Set in POWER CONDITION MODE PAGE When Mode Sense (10) is executed to NON EPC SATA Drive(SCGCQ01518957 port of SCGCQ00845242) 
 - Need to expose pure SEP devices through the inventory command(SCGCQ01519056 port of SCGCQ00943216) 
 - pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01519802 port of SCGCQ01518343) 
 - pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01522511 port of SCGCQ01487423) 
 - pl: backend PCIe: 4311 fault with NVMe enabled (part 2)(SCGCQ01523550 port of SCGCQ01523531) 
 - Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01525228 port of SCGCQ01450475) 
 - pl: backend PCIe: non-NVMe endpoint not cleaned up on removal(SCGCQ01529383 port of SCGCQ01516968) 
 - PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB(SCGCQ01529512 port of SCGCQ01509770) 
 - PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01533308 port of SCGCQ01505468) 
 - PL Fault 0000ecdd LR 01403837 during initial discovery(SCGCQ01539840 port of SCGCQ01531770) 
 - Increase the default SES buffer size to 2K(SCGCQ01540666 port of SCGCQ01506013) 
 - PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01556419 port of SCGCQ01520524) 
 - pl: backend PCIe: switch attached discovery takes too long(SCGCQ01556426 port of SCGCQ01522343) 
 - Collect enclosure Bay ID from OEM specificinternal backplanes(SCGCQ01562101 port of SCGCQ01503517) 
 - pl: NVMe: device may not appear in OS following NVMe init failure(SCGCQ01594709 port of SCGCQ01593528) 
 - pl: NVMe: Write Long (10)(SCGCQ01595859 port of SCGCQ01593652) 
 - DDRlib failures occur if debug prints are disabled.(SCGCQ01599770 port of SCGCQ01482222) 
 - pl: NVMe: D102 fault(SCGCQ01608155 port of SCGCQ01605590) 
 - (SATA Only)SCSI Unmap command to some SATA drives are timing out.(SCGCQ01615122 port of SCGCQ01539572) 
 - (SATA Only)ATA Request Sense Ext command sometimes not send when the drive responds with 'Sense Data Available' bit set.(SCGCQ01615159 port of SCGCQ01571933) 
 - (SATA Only)Only) ATA Request Sense Ext command not sent for failed SCSI Unmap command sent to a SATA drive.(SCGCQ01615209 port of SCGCQ01593844) 
 - (SATA Only)Only) Incorrect data sent in response of SCSI Inquiry command for some SATA drives.(SCGCQ01616465 port of SCGCQ01599707) 
 - Increase the default SES buffer size to 2K.(SCGCQ01616503 port of SCGCQ01506013) 
 - (SATA Only)Only) Timer for SCSI Write Verify command to a SATA drive might get removed before command completion.(SCGCQ01616558 port of SCGCQ01593136) 
 - (SATA Only)Only) ATA Request Sense Ext command being sent after ATA command translated for SCSI Start Stop Unit command fails with Sense Data Available.(SCGCQ01618209 port of SCGCQ01599542) 
 - Task Management due to SATA init failure results in resource error message(SCGCQ01618661 port of SCGCQ01605610) 
 - pl: backend PCIe: EC59 fault(SCGCQ01618750 port of SCGCQ01615981) 
 - PL Enclosure Management: SEP Blink Request Fails After Path 1 Disconnect in Multipath Topology(SCGCQ01619021 port of SCGCQ01618625) 
 - pl: NVMe: 61A6 fault.(SCGCQ01619934 port of SCGCQ01602703) 
 - (SATA Only)SCSI Unmap command to some SATA drives are timing out.(SCGCQ01621120 port of SCGCQ01539572) 
 - Not all NVMe drives are discovered on VPP backplane Enclosure.(SCGCQ01623525 port of SCGCQ01620856) 
 - IO starvation and performance degradation when using dma Q masking feature.(SCGCQ01627326 port of SCGCQ01505074) 
 - When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01628174 port of SCGCQ01601413) 
 - The change detect feature macro missing, leading to compilation issue(SCGCQ01628450 port of SCGCQ01616460) 
 - The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628453 port of SCGCQ01623437) 
 - (SATA Only) Incorrect Sense Key and Additional Sense Code set for failed Start Stop Unit command.(SCGCQ01630267 port of SCGCQ01628346) 
 - Ventura: No easy way to tell if config pages have been written(SCGCQ01630398 port of SCGCQ01630331) 
 - Ventura B0: 5813 fault while running destructive domain test(SCGCQ01630895 port of SCGCQ01623624) 
 - Negotiated Link Speed for the vSES target is displayed as 'Unknown'.(SCGCQ01639536 port of SCGCQ01606720) 
 - SES Page 2 does not show the correct status information for Direct Attached NVMe drives(SCGCQ01639840 port of SCGCQ01620857) 
 - Blank Boards with Auto Port Enable set in NVDATA will fault(SCGCQ01639859 port of SCGCQ01553238) 
 - SES Page 2 Overall Status-Status Info bits do not reflect the correct status after fault conditions are cleared(SCGCQ01639873 port of SCGCQ01620243) 
 - Align vSES diag page response with Expander SEP diag page response(SCGCQ01639886 port of SCGCQ01585387) 
 - MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN(SCGCQ01675747 port of SCGCQ01631826) 
 - Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676883 port of SCGCQ01670180) 
 - Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01682349 port of SCGCQ01670965) 
 - pl: NVMe: E411 fault(SCGCQ01686689 port of SCGCQ01684788) 
 - IO unit control IOC_CTRL_OP_ALL_PHY_LOOPBACK_DIAG hangs on 8 phy controller(SCGCQ01687624 port of SCGCQ01623477) 
 - Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01687743 port of SCGCQ01619417) 
 - Mercator Phase7: VMWare PSODs due to NMI error when the Windows VM that has passthrough controller is being shutdown(SCGCQ01697675 port of SCGCQ01617769) 
 - VPD is not shown by lspci(SCGCQ01698316 port of SCGCQ01687750) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01713180 port of SCGCQ01681441) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01714249 port of SCGCQ01681441) 
 - Unhandled exception results in a fault(SCGCQ01721368 port of SCGCQ01686666) 
 - (SATA Only) When ATA command fails with sense data available bit set, Data frame may not be released.(SCGCQ01745744 port of SCGCQ01732835) 
 - MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events(SCGCQ01760767 port of SCGCQ01742362) 
 - Host memory corruption seen during Progress polling of Sanitize operation on SATA drives(SCGCQ01762343 port of SCGCQ01721050) 
 - IO not completing or being timed out if some cases when an unconfirmed response is received for an IO.(SCGCQ01767091 port of SCGCQ01718897) 
 - PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request(SCGCQ01788903 port of SCGCQ01614814) 
 - IOC_CTRL_OP_ALL_PHY_LOOPBACK operation is not working(SCGCQ01792619 port of SCGCQ01670396) 
 - pl: backend PCIe: port enable may complete before PCIe mode is attempted(SCGCQ01794153 port of SCGCQ01760627) 
 - [Ventura][PL] Applications trying to update NVMe device Firmware with Mode E fails.(SCGCQ01849388 port of SCGCQ01624790) 
 - Ventura PL: Check in Revised Workaround for 0x5842 fault - Rx Dma Memory Overflow(SCGCQ01896576 port of SCGCQ01864843) 
 - Add workaround for SATA drive not complaint with ACS-3(SCGCQ01935094 port of SCGCQ01922154) 
 - (NVME)Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.(SCGCQ01944370 port of SCGCQ01932728) 
 - Source code uses tlbInitHDCW and HDCW instead of HCDW(SCGCQ01118580 port of SCGCQ01089693) 
 - PL: SSD drop by SAS3008 during the hotplug test.(SCGCQ01516685 port of SCGCQ00897639) 
 - Coverity defects : The function seem called twice and identical code in different branches.(SCGCQ01516906 port of SCGCQ00939071) 
 - Ventura hardware does not like the IOP enable method used here.(SCGCQ01519729 port of SCGCQ01514880) 
 - (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices(SCGCQ01524353 port of SCGCQ01516277) 
 - Controller is not detecting in the storelib, after changing the mode from "set mode oob" command(SCGCQ01530310 port of SCGCQ01494018) 
 - pl: NVMe: EC0D fault.(SCGCQ01533267 port of SCGCQ01530402) 
 - Storlib observed ERROR_MCTP_PAYLOADID_PE_INVALID_PARAM while doing attn-btn test(SCGCQ01542429 port of SCGCQ01423338) 
 - covery defects on Intruder 19849 & 19842(SCGCQ01542431 port of SCGCQ01484250) 
 - pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment(SCGCQ01556893 port of SCGCQ01540226) 
 - Performance Improvements(SCGCQ01562099 port of SCGCQ01455538) 
 - pl: NVMe: modify Bus Master Enable usage during NVMe controller reset(SCGCQ01587095 port of SCGCQ01581273) 
 - pl: backend PCIe: generic message header dWords 2 and 3 are swapped(SCGCQ01599051 port of SCGCQ01598812) 
 - Ventura B0 Phase 7 - Fault E404 during IOTM testing with 24 NVMe drives and 3 switches(SCGCQ01600602 port of SCGCQ01570622) 
 - Requested capacity field translations are incorrect for remove element & truncate command(SCGCQ01614097 port of SCGCQ01510418) 
 - (SATA Only) ATA Request Sense Data Ext command not send to device when it fails translated SCSi Security Protocol Out.(SCGCQ01618558 port of SCGCQ01605100) 
 - Ventura: FW Signing Support failing with loginfo during FWDL(SCGCQ01618988 port of SCGCQ01605427) 
 - pl: NVMe: hot-added device may not appear in OS during heavy IO load(SCGCQ01619018 port of SCGCQ01616267) 
 - Ventura: Duplicate slot numbers assigned for drives in certain mixed mode cabling configurations(SCGCQ01623485 port of SCGCQ01606122) 
 - pl: NVMe: ECEC fault(SCGCQ01623903 port of SCGCQ01620613) 
 - To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01628440 port of SCGCQ01507506) 
 - Change detect feature support on UBM supported back plane(SCGCQ01628444 port of SCGCQ01605371) 
 - The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628452 port of SCGCQ01623437) 
 - (SATA Only) SCSI Log Select command not failed with check condition when translated ATA command is failed by SATA drive.(SCGCQ01633320 port of SCGCQ01631836) 
 - PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01639906 port of SCGCQ01505468) 
 - PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01646094 port of SCGCQ01572062) 
 - Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01681401 port of SCGCQ01670965) 
 - Not all NVMe drives were discovered after server cold or warm boot(SCGCQ01732107 port of SCGCQ01664963) 
 - Not all NVMe drives discovered as part of hot plug operation(SCGCQ01732136 port of SCGCQ01697329) 
 - The x4 link configuration was not detected by UBM module(SCGCQ01735502 port of SCGCQ01735485) 
 - PL: Avoid Duplicate Mid Workaround Does Not Start a TM If Device is Removed and Re-Added(SCGCQ01748033 port of SCGCQ01715677) 
 - PL support for monitoring the progress of sanitize operation.(SCGCQ01753174 port of SCGCQ01591935) 
 - When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01761718 port of SCGCQ01601413) 
 - Data NAK of large master TX packet can stop I2C out of band(SCGCQ01766431 port of SCGCQ01713685) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01798286 port of SCGCQ01792208) 
 - To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues(SCGCQ01851004 port of SCGCQ01765873) 
 - Ventura: Attaching multiple PCIe switches may cause IOP memory corruption(SCGCQ01875221 port of SCGCQ01853893) 
 - pl: backend PCIe: 4311 fault with NVMe enabled(SCGCQ01520574 port of SCGCQ01514521) 
 - (SATA Only)Security Protocol In command complete without data transfer for allocation length not a multiple of 512(SCGCQ01524638 port of SCGCQ01275335) 
 - pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset(SCGCQ01527219 port of SCGCQ01526236) 
 - IOP: FW to clear all pending PCI interrupts during a Function Level Reset (FLR(SCGCQ01534881 port of SCGCQ01523541) 
 - pl: backend PCIe: potential address range overlap(SCGCQ01592870 port of SCGCQ01586393) 
 - Fixing the issues during bringup of the universal backplane.(SCGCQ01599610 port of SCGCQ01522148) 
 - Race condition can allow IOs over OOB to removed drive, with no host IOs, to not be cleaned up, and possibly leading to new drives not showing up(SCGCQ01605489 port of SCGCQ01400110) 
 - (SATA Only) Incorrect Additional sense code when SCSI Format to a SATA drive fails(SCGCQ01615216 port of SCGCQ01598756) 
 - (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct.(SCGCQ01668674 port of SCGCQ01638248) 
 - Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01698231 port of SCGCQ01619417) 
 - PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715880 port of SCGCQ01715509) 
 - PL support for monitoring sanitize operation after controller/device reset.(SCGCQ01753176 port of SCGCQ01591995) 
 - [ventura] PL Fault 0000ecc9 observed, while running doing drive Pull-Push with IO's in background(SCGCQ01817256 port of SCGCQ01804290) 
 - Ventura MSS: Multi-bit ECC, EFI SAS DRIVER issue seen when performed multi reboot stress from UEFI(SCGCQ01822452 port of SCGCQ01794025) 
 - Heavy IO with low IO timeout test may result into an IO getting missed.(SCGCQ01840466 port of SCGCQ01631346) 
 - Fault 4311 when running repeated controller resets(SCGCQ01872930 port of SCGCQ01865882) 
 - Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.(SCGCQ01893313 port of SCGCQ01671177) 
 - Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01530305 port of SCGCQ01450475) 
 - pl: NVMe: unexpected target reset task management timeout(SCGCQ01587064 port of SCGCQ01580026) 
 - PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01615056 port of SCGCQ01572062) 
 - PL: (SATA Only)SSU Command for active power condition transition on EPC enabled drive fails with Additional sense Logical block address out of range(SCGCQ01640974 port of SCGCQ01640762) 
 - (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command.(SCGCQ01714280 port of SCGCQ01681441) 
 -(SCGCQ01748041 port of SCGCQ01615484) 
 - [Ventura][PL] TM Hangs when doing drive push pull test case(SCGCQ01817002 port of SCGCQ01792208) 
 - (SATA Only) SCSI Start Stop Unit command with power condition set to standby may fail for SATA drives.(SCGCQ01839608 port of SCGCQ01833392) 
 - To fix issues for back plane configuration validation and LED control for the UBM backplane.(SCGCQ01599611 port of SCGCQ01533852) 
 - IO starvation and performance degradation when using dma Q masking feature(SCGCQ01630921 port of SCGCQ01505074) 
 - ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA.(SCGCQ01684232 port of SCGCQ01639482) 
 - PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715875 port of SCGCQ01715509) 
 - PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01749480 port of SCGCQ01520524) 
 - Avoid releasing I2C bus when I2C operation(Read/Write) in progress.(SCGCQ01752794 port of SCGCQ01721931) 
 - To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01599612 port of SCGCQ01542497) 
 - Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01599616 port of SCGCQ01574224) 
 - MCTP: Fault 0x265D when packet with StartOfMsg is set and PktSeqCount is 1(SCGCQ01966436 port of SCGCQ01850721) 
 - vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.(SCGCQ01967409 port of SCGCQ01942781) 
 - To fix the LED issue, VPP data and moving to change detect poll state(SCGCQ01599614 port of SCGCQ01576165) 
 - Change detect feature support on UBM supported back plane(SCGCQ01628442 port of SCGCQ01605371) 
 - Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676884 port of SCGCQ01670180) 
 - pl: NVMe: 61A6 fault(SCGCQ01763390 port of SCGCQ01602703) 
 - [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.(SCGCQ01906461 port of SCGCQ01906013) 
 - (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.(SCGCQ01961501 port of SCGCQ01955094) 
 - pl: backend PCIe: 4311 fault (part 3)(SCGCQ01574923 port of SCGCQ01537791) 
 - The x4 link configuration was not detected by UBM module(SCGCQ01747034 port of SCGCQ01735485) 
 - vSES: Remove, RRAbort and Missing bits in array device element are not getting updated in element status page.(SCGCQ01967384 port of SCGCQ01932394)
   
	
EnhancementRequests:
 - SATA SMR Only : Change for the FORMAT UNIT translation for SMR drives to also call RESET WRITE POINTER with ALL bit set(SCGCQ01218300) 
 - Add PLI Control Request to Fully Pause/Unpause FPE HW(SCGCQ01378809) 
 - Aero-3: CR#06: SPILib: Add necessary SPI timings to Aero/Sea to support multiple SPI Vendors(SCGCQ01380051) 
 - Aero-3: Update Clock, Configuration, and Reset (CCR) code.(SCGCQ01380109) 
 - Incorporate new PHY register initialization settings.(SCGCQ01405307) 
 - Aero DDR: PHY based Read Leveling(SCGCQ01405427) 
 - Aero DDR: PHY based Write Leveling(SCGCQ01405430) 
 - Aero: Internal Boot ROM Support(SCGCQ01410019) 
 - pl: backend PCIe: add API for getting backend PCIe link configurations(SCGCQ01437182) 
 - Re-enable flash initialization in bootloader.(SCGCQ01448314) 
 - (SATA Only) Add support for FIS Port (NCQ Encapsulation) of SCSI Write Same command.(SCGCQ01452113) 
 - MegaRaid VT BootLoader Flash Map Update For Ventura(SCGCQ01467197) 
 - Aero-3: Create framework for M0 processors(SCGCQ01499419) 
 - SAS3.5 (SATA Only): SATL need to send ATA REQUEST SENSE DATA EXT command when ATA device returns error and sense data available bit is on(SCGCQ01503732) 
 - Rebase Aero3 Development Stream and Verify Ventura Functionality(SCGCQ01509806) 
 - Ventura: Add MCTP over I2C Master Mode Option that doesn't use I2C DMA(SCGCQ01516871) 
 - Enable Backplane Management based on backplane type signal per HBA connector quad(SCGCQ01524982) 
 - pl: NVMe: add NVMe task management test code(SCGCQ01526049) 
 - Ventura: Specify leading zeros for the prints using %x in pl diag module(SCGCQ01533485) 
 - Aero-3: Update RMC FW to follow the steps from Aero SOC uArch spec(SCGCQ01533491) 
 - Add a new flag to IoFlags in pliStartScsiIo(SCGCQ01544740) 
 - Ventura: Ensure new I2C non_DMA code compiles with MCTP disabled(SCGCQ01548925) 
 - Remove ENET(Ethernet support Bit 26(SCGCQ01555034) 
 - Remove CSW library from AERO builds(SCGCQ01558186) 
 - Change the default behavior for I2C MCTP to non-DMA(SCGCQ01565737) 
 - Intruder: Modify NVDATA to enable DMA by default(SCGCQ01566619) 
 - Update build to calculate build duration(SCGCQ01572912) 
 - Ventura: Specify leading zeros for the prints using %x in plDebugStrings(SCGCQ01576200) 
 - pl: NVMe: add support for Security Protocol In/Out INC_512 flag(SCGCQ01582520) 
 - Disable mapping of some device side PCIe hardware into CPU's virtual address space(SCGCQ01582599) 
 - Aero-3: Modify CBB build so that it decreases the hardware reserved area (SBR(SCGCQ01595798) 
 - RMC must add PCE PLL/Core Initialization for Secure Mode(SCGCQ01608224) 
 - Aero-3: Review Aero Impala changes(SCGCQ01614623) 
 - Aero-3: Review Aero SAS core changes(SCGCQ01614628) 
 - Aero: backend PCIe: update config pages for 16GT/s(SCGCQ01614647) 
 - Flag added in AERO to avoid sending IO requests to IOA NVMe core that could potentially cause exceptions(SCGCQ01615545) 
 - Aero: enable backend PCIe support in the Aero build(SCGCQ01619936) 
 - pl: backend PCIe: basic PCI hot plug power controller support for switches(SCGCQ01633888) 
 - Aero DDR: DDR library initialization on the FPGA(SCGCQ01634738) 
 - pl: NVMe: remove vendor specific prototype code(SCGCQ01638257) 
 - pl: NVMe: support for nonzero doorbell stride(SCGCQ01670300) 
 - SPI_LIBRARY: Aero/Ventura Provide Sufficient Information to Uniquely Detect Auto-Configured devices(SCGCQ01679097) 
 - Improve build times(SCGCQ01715410) 
 - Fine Tune iMR RAID IO path performance(SCGCQ01715637) 
 - Add debug print for unrecognized initial FIS(SCGCQ01718317) 
 - Aero: Move RSA defines in mpi_temp.h to a common area(SCGCQ01727399) 
 - ComboSerdes: add APIs for firmware coordination with the protocol cycler(SCGCQ01761386) 
 - Convert Aero build to Aero3(SCGCQ01349949) 
 - Aero Fpga support(SCGCQ01367141) 
 - Aero-3: Update ARM CPU Speed to 1600 MHz(SCGCQ01392205) 
 - Aero: Add 300MHZ UART Clock Reference Support(SCGCQ01392831) 
 - Aero3: Add secure boot specified header and add support in rom utilities for it(SCGCQ01399079) 
 -(SCGCQ01418823) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473898) 
 - PL: Create defines for plRequestFWBreak() Location Parameter(SCGCQ01499053) 
 - Aero-3: Ensure modifed SBR template data is compatible with Ventura(SCGCQ01509915) 
 - Support for NVDATA control of static slot number assignments for x2 or x4 NVMe devices(SCGCQ01511787) 
 - Ventura: Use non-DMA option for MCTP over I2C - Slave Mode(SCGCQ01516865) 
 - Ventura: Add symbol names to "iop show gic"(SCGCQ01519283) 
 - PCIe Switch attached NVMe Backplane LED Management support(SCGCQ01532296) 
 - Add Margay expander recognition to Ventura(SCGCQ01570647) 
 - Allow filtering of NVMe exception prints in debug mask(SCGCQ01575138) 
 - pl: NVMe: more NVMe TM test code(SCGCQ01605900) 
 - pl: backend PCIe: merge extended capability search functions(SCGCQ01613997) 
 - PL SATL: ZNR bit translation during SCSI SANITIZE command for SMR drive(SCGCQ01615513) 
 - Delete strings that are not used in plDebugStrings(SCGCQ01620668) 
 - Aero: backend PCIe: basic Atlas host interface board bringup(SCGCQ01736527) 
 - Ventura/Marlin: Detect attempt to downgrade from auto-detected SPI parts to non-auto and fail(SCGCQ01449329) 
 - PL: Use Sense Data from SATA Log Page 10 when querying Log Page 10(SCGCQ01459375) 
 - Aero: backend PCIe: modify outbound address window configuration(SCGCQ01485166) 
 - Ventura: Modify DMAless-I2C MCTP code so that that it processes most data in interrupts(SCGCQ01533036) 
 - Update tcc to version 0.9.27(SCGCQ01593619) 
 - PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request(SCGCQ01614814) 
 - Ventura/Aero: (Child) Implement Extended Mfg Page 45 - Aladin Config Page - Add config page(SCGCQ01680542) 
 - To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01507506) 
 - Aero-3: Modify the Aero3 build so that the main firmware image has a MPI Component Header(SCGCQ01509807) 
 - Aero-3: Disable MCTP over PCIe VDM Workarounds(SCGCQ01533532) 
 - Ventura: Detect various user errors in firmware download(SCGCQ01534545) 
	
 

Version  06.02.00.02
---------------
Contains:
    BIOS            Firmware      UEFI Driver
  9.11.00.00        06.00.16.00   06.04.02.00
  
Fixed: Bug 142622 - [Libra] One of the SAS port from Lenovo 430-16e failed to log back to the controller during controller reset

Defects (4)
- pl: NVMe: ED8D fault related improvements.(SCGCQ01789903)
- PDB data path parity error workaround.(SCGCQ01733783)
- To support the SEP reset functionality through CPERST in order to avoid warm boot CPLD issues.(SCGCQ01765873)
- Ventura: Locate operation to SAS/SATA drive slot may not turn on the status LED on OEM backplane.(SCGCQ01789068)
- PL: Add NVDATA Option to Force Programmed Physical Link Rates to 0 in SMP Phy Control Request.(SCGCQ01788903 port of SCGCQ01614814)
- When spinup delay in expander is configured to a high value it might result in some drives being reset by controller repeatedly.(SCGCQ01761718 port of SCGCQ01601413)
- [Ventura][PL] TM Hangs when doing drive push pull test case.(SCGCQ01798286 port of SCGCQ01792208)
- pl: NVMe: 61A6 fault.(SCGCQ01763390 port of SCGCQ01602703)

EnhancementRequests (1)
- Permit multiple calls to avSerdesSASSDAddTxEqSeq and implement aviSerdesSASSDWaitIntrSmIdle for SAS35XFW.(SCGCQ01720492)

Version 06.01.00.07
---------------
Contains:
    BIOS            Firmware      UEFI Driver
  9.11.00.00        06.00.12.00   6.04.00.00

Defects (96)
- SAS Power Management and PCal do not work together.(SCGCQ01201827)
- pl: backend PCIe: ECE4 fault.(SCGCQ01312345)
- Ventura SBR: Changes to PLL reset requirements cause lock failure on some boards.(SCGCQ01373888)
- IOP: Improvements to AXI HWWA.(SCGCQ01390095)
- Ventura B0: Missing signing supported firmware image in RO.(SCGCQ01392675)
- PCI SIG Compliance Test Failure - Test 1_41 Link Capabilities 2, Link Control 2, Link Status 2 Failures.(SCGCQ01394478)
- Customer specific SAS 12g drive frequently links up at 6g..(SCGCQ01397553)
- pl: NVMe: async event persistent conditions monitor issues.(SCGCQ01414966)
- Internal Task Management operations not completing in out of resource conditions.(SCGCQ01415544)
- 0x6004 Fault during TM injection while running IO to Sata SSDs..(SCGCQ01416481)
- Add SAS device discovery error event to IOP message events..(SCGCQ01428178)
- Ventura: Misc tri-mode backplane mgmt detection fixes and Slot status update changes.(SCGCQ01428718)
- pl: NVMe: memory leak in Verify (10/12/16) command translation.(SCGCQ01429659)
- pl: Mode Select translation transfer length validation.(SCGCQ01435884)
- File name capitalization doesn't match #include and fails when building with Linux.(SCGCQ01439249)
- SGPIO Clock driven Low on host PCIe reset assertion causing SGPIO target to latch on invalid data.(SCGCQ01440481)
- Ventura B0: Fault 0x510B while doing reboot test along with IOs & TMs.(SCGCQ01440764)
- Ventura: NVMe Target: REPORT LUNS SCSI Command Failed With CC for Supported SELECT REPORT field Values 01h, 10h or 12h.(SCGCQ01444725)
- Ventura: NVMe Target: When MODE SENSE Command Executed for all supported Modes Pages, TRACK SKEW FACTOR Set as 0x01.(SCGCQ01444843)
- A previous code change is missing a few changes..(SCGCQ01449239)
- PL trying to perform memory move using address which is in the non-addressable range.(SCGCQ01450399)
- pl: NVMe: EC26 fault.(SCGCQ01451332)
- vSES Target: Incorrect Sense Data for REQUEST SENSE Command.(SCGCQ01451678)
- pl: backend PCIe: erroneous address pool copy.(SCGCQ01455651)
- pl: port enable may fail to complete if an OEM backplane is attached.(SCGCQ01455680)
- Ventura: Break up backplane mgmt device ISTWI Read/Write to the supported size.(SCGCQ01456349)
- Hot plugged NVMe drive fails to link up on OEM backplanes with ISTWI drive presence polling enabled.(SCGCQ01463496)
- Ventura: Firmware Update Algorithm Frees Mids Twice.(SCGCQ01465058)
- pl: NVMe: 6001 fault.(SCGCQ01468144)
- To support the I2C bus reserve state in the case of UBM backplane.(SCGCQ01470385)
- pl: NVMe: port enable may complete before devices link up.(SCGCQ01472531)
- Ventura VSES: Incorrect data in diagnostic page 0xA when drive is missing but not yet removed..(SCGCQ01472941)
- The "pl reg" command dumps the wrong amount of data for some structures..(SCGCQ01474266)
- PL: SATA: Sense Key/Additional Sense code incorrectly set when open zone issued on a Security locked SMR drive.(SCGCQ01478037)
- Ventura vSES: Direct attached NVME drives are not getting associated with vSES in Microsoft Storage Spaces Direct..(SCGCQ01478170)
- Drive addition in OS takes longer time when Drives are connected with certain backplanes to the controller.(SCGCQ01479406)
- SATL: Security Protocol Erase fails in SATL, but works well with ATA PT.(SCGCQ01479409)
- pl: NVMe: task management timeout may occur.(SCGCQ01480646)
- Ventura B0: Controller Reset causing OS hang and resets.(SCGCQ01480987)
- MPI SEP request to Slots with invalid SES Page 0A element index may not complete.(SCGCQ01482937)
- pl: NVMe: improved fix for 6001 fault.(SCGCQ01484382)
- pl: 265D fault on 'pl dbg' before port enable.(SCGCQ01485059)
- (SATA Only) Format of SATA SSD takes long time.(SCGCQ01485060)
- Ventura/Marlin: Firmware Download does not protect user from downgrading to firmware that does not support Winbond.(SCGCQ01485441)
- Host application hangs waiting for completion of IO issued after NVMe device is removed.(SCGCQ01486695)
- pl: NVMe: switch attached devices not detected under Windows.(SCGCQ01487291)
- SATA: Report Zone for very large data of 4MB takes ~2 seconds for processing.(SCGCQ01502700)
- Ventura FW may fault on single bit correctable ECC errors in IOA Local RAM.(SCGCQ01503262)
- pl: backend PCIe: additional phy hardware cleanup on link down and hot reset.(SCGCQ01504284)
- pl: backend PCIe: LTSSM state wait during hot reset.(SCGCQ01504310)
- SAS3.5FW_Common_Main was not stable after merging code changes for SCGCQ01421231.(SCGCQ01508018)
- (SATA Only) SCT Error Recovery Control read using ATA Passthrough is not returning correct values.(SCGCQ01509632)
- Ventura: 4311 fault with NVMe enabled.(SCGCQ01519732)
- pl: backend PCIe: 4311 fault with NVMe enabled (part 2).(SCGCQ01522342)
- pl: backend PCIe: 4311 fault (part 3).(SCGCQ01571588)
- Ventura B0: Windows server 2016 OS may not detect all drives on OEM backplane in a mixed mode config.(SCGCQ01592762)
- Device block and unblock messages observed for the existing connected NVMe drives when new NVMe drive is inserted.(SCGCQ01615532)
- pl: backend PCIe: ED8D fault.(SCGCQ01628411)
- SGPIO SCLK Glitch and Low upon coming out of reset.(SCGCQ01697481)
- pl: NVMe: ED8D fault.(SCGCQ01698373)
- pl: backend PCIe: E984, E9A4, EF50, EF52 faults.(SCGCQ01294948)
- Task Management request of Abort Task to an NVMe device completes with failure status if the target of the Abort is not a currently active IO from the controller's point of view.(SCGCQ01334586)
- pl: NVMe: missing AccessStatus codes.(SCGCQ01352937)
- Doorbell handshake hangs when faulted.(SCGCQ01384089)
- PCI SIG Compliance Test Failure - Test 1_8 Virtual Channel.(SCGCQ01394426)
- The Avoid Duplicate Mid feature does not activate properly for expander attached SATA devices.(SCGCQ01405083)
- When disabling one phy of a port the other phys of the same port do not relink after reset..(SCGCQ01418575)
- 9405W-16i xml not available in Latest Release Order.(SCGCQ01429439)
- GoldenX: When no BIOS option is selected the images are 1MB too small.(SCGCQ01448015)
- Ventura: NVMe : Log Sense Command Executed for Information Exceptions Log Page has TSD field set to 0b.(SCGCQ01448752)
- pl: backend PCIe: link may fail to come up after link break.(SCGCQ01451278)
- (VSES) SES INQUIRY commands and storcli commands hang while getting adapter information.(SCGCQ01458388)
- pl: NVMe: issues related to port enable completion.(SCGCQ01464247)
- PL: Modify internal structures.(SCGCQ01487864)
- Intermittent Update firmware failed with M0 using EFI StorCLI.(SCGCQ01487866)
- Global HDD LED may not indicate IO activity for NVMe or SAS drives.(SCGCQ01489030)
- Code Unstable in Common_Main, Re definitions of Macro IOP_TIMED_CONDITION, consolidating them.(SCGCQ01489981)
- 0x7C41 Fault doing IOs and Task Managements on a mixed SAS/NVMe topology..(SCGCQ01494379)
- pl: SATA: port enable may time out on spinup failure.(SCGCQ01496842)
- IOP MCTP: Changes missing from a previous code change.(SCGCQ01497080)
- Fixing coverty defects 19848 & 19838.(SCGCQ01504066)
- Ventura: Slot LEDs on SGPIO based backplane may not blink.(SCGCQ01505392)
-.(SCGCQ01615484)
- PL: More than one ATA command at a time may be submitted to a SATA device.(SCGCQ01377242)
- Drive missing on power cycle.(SCGCQ01421447)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated.(SCGCQ01450475)
- vSES Target: Allocation Length less than 16 Bytes for REPORT LUNS Command is not Handled Properly.(SCGCQ01451022)
- MCTP: Fault 0x265d while doing enclosure pull/push with OOB StoreLibIT when enabling AEN.(SCGCQ01631826)
- MCTP PCIe VDM: controller stops responding after sending over 1000 asynchronous events.(SCGCQ01742362)
- Ventura: NVMe Target: Non-Zero Value in TRACK SKEW FACTOR field of FORMAT DEVICE Mode Page.(SCGCQ01412908)
- (SATA Only) Function field in MPI error reply message for SCSI ATA Pass-through request is not correct..(SCGCQ01638248)
- Negotiated Link Speed for the vSES target is displayed as 'Unknown'..(SCGCQ01606720)
- Not all NVMe drives were discovered after server cold or warm boot.(SCGCQ01664963)
- Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes..(SCGCQ01671177)
- VPD is not shown by lspci.(SCGCQ01687750)
- Not all NVMe drives discovered as part of hot plug operation.(SCGCQ01697329)

EnhancementRequests (40)
- Ventura: Remove VENTURA_PORTING from ARM Initialization/Utilities..(SCGCQ00922893)
- Ventura: Move firmware update copy process to main firmware to avoid PCE problems.(SCGCQ01230723)
- Ventura/Marlin: When the SPICO code fails checksum, Patch SPICO Signature and Checksum.(SCGCQ01240422)
- pl: NVMe: support for devices with large sector sizes.(SCGCQ01275066)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- Ventura: Enclosure Mgmt optimizations and enhancements.(SCGCQ01328437)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- Ventura B0:(UBM) Identifying a UBM Capable backplane.(SCGCQ01412194)
- To read the port Capabilities from backplane implementing UBM and to validate backplane configuration.(SCGCQ01412195)
- Enable I2C polling for drive presence detection in UBM backplanes with NVMe support..(SCGCQ01412198)
- Controlling Slot Locate/Fault LEDs in a backplane which implements UBM..(SCGCQ01412209)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- pl: NVMe: NVMe task management modifications.(SCGCQ01419083)
- Ventura: NVMe 1.3 Support: Firmware Update Granularity.(SCGCQ01430672)
- Ventura: NVMe 1.3 Support: Namespace Optimal IO Boundary.(SCGCQ01430674)
- Ventura: NVME 1.3 Support: Add new Status Codes to header files.(SCGCQ01434061)
- pl: NVMe: don't require a resource frame for some SCSI-NVMe translations.(SCGCQ01436612)
- pl: NVMe: SGL translation performance tweaks.(SCGCQ01440247)
- PL: Add firmware support for depopulation of SATA drives.(SCGCQ01445877)
- pl: NVMe: NVMe task management modifications (part 2).(SCGCQ01445903)
- Reduce time taken by host to initialize one SATA drive..(SCGCQ01448575)
- (SATA Only) Add support for SCSI Read Capacity command when drive is in spun down mode..(SCGCQ01448576)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- (SATA Only) Add support for NDOB bit in translation of SCSI Write Same Command to SATA drives.(SCGCQ01454125)
- Ventura: Re-order pl dbg to put most useful, less verbose prints first.(SCGCQ01454612)
- Ventura/Marlin: Change to ARM site licenses.(SCGCQ01461714)
- Ventura: Change iopiDiagCmdReadMem() to not print rows of zeros.(SCGCQ01462690)
- Ventura: Modify plDiagCmdShowRegister() to skip printing of dwords of 0 when regSize == 4..(SCGCQ01464914)
- PL: Add NVDATA option to gracefully handle invalid BP Type configurations.(SCGCQ01464951)
- pl: backend PCIe: reduce firmware initiated PCIe transaction wait time.(SCGCQ01465016)
- pl: NVMe: add debug print to the NVMe encapsulated failure path.(SCGCQ01487366)
- Ventura: Remove VENTURA_PORTING from Makefiles and headers.(SCGCQ00922883)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
- pl: NVMe: IO breakup structure modification.(SCGCQ01431067)
- Skipping additional reserved registers when printing pl dbg trace.(SCGCQ01468138)
- PL: Use Sense Data from SATA Log Page 10 when querying Log Page 10.(SCGCQ01459375)
- Reduced amount of data in pl dbg trace output.(SCGCQ01394882)
- Ventura/Marlin: Add support for Winbond 256Mbit SPI FLASH.(SCGCQ01449325)

CSETActivities (88)
- PL : Drives may not spin up due to bug in spin up path found during code walk through.(SCGCQ01385320 port of SCGCQ01358138)
- PL: Change avoid duplicate mid LUN reset option to abort task set.(SCGCQ01429867 port of SCGCQ01429655)
- PL: More than one ATA command at a time may be submitted to a SATA device(SCGCQ01435779 port of SCGCQ01377242)
- Ventura VSES: Unique id and serial number for virtual SES to support microsoft storage spaces direct(SCGCQ01436959 port of SCGCQ01404241)
- Ventura vSES: SAS and SATA direct attached devices are not getting associated to vSES in Windows Storage Spaces Direct..(SCGCQ01442629 port of SCGCQ01438119)
- Ventura B0: Missing signing supported firmware image in RO(SCGCQ01443281 port of SCGCQ01392675)
- PCI SIG Compliance Test Failure - Test 1_8 Virtual Channel(SCGCQ01443732 port of SCGCQ01394426)
- Direct attached VSES Enclosure validation may fail with certain OS tools(SCGCQ01451190 port of SCGCQ01445053)
- MCTP I2C: I2C communication is lost between BMC and controller(SCGCQ01455876 port of SCGCQ01385782)
- PL : PWR_GRANT is not issued upon PWR_REQ from SPL2 drive(SCGCQ01458074 port of SCGCQ01330984)
- PL : PL fault 0x7C72 is hit during discovery when disabling and enabling all the PHYs connected to legacy SAS drives(SCGCQ01458664 port of SCGCQ01455200)
- Limit printing a SGL chain to only 15 elements(SCGCQ01468156 port of SCGCQ01180961)
- PL: Add Code to Correctly Determine Mid for Rx Context Non-automated Interrupts(SCGCQ01479502 port of SCGCQ01472512)
- IOP: 0x265D Fault Observed on Cold Boot of Customer Server with Misconfigured Controller NVDATA(SCGCQ01505077 port of SCGCQ01473138)
- PL SATL: SCSI Write Buffer Mode 7 Command Incorrectly Failed by Firmware(SCGCQ01505080 port of SCGCQ01498114)
- IOP: I2C MCTP: Slave response mode fails to return response to I2C read(SCGCQ01508067 port of SCGCQ01506883)
- Fault State (0x265d) is Observed While Connecting an Enclosure with Fully Populated SATA Drives(SCGCQ01514262 port of SCGCQ00856085)
- pl: backend PCIe: workaround timer may trigger after too short of an interval(SCGCQ01519802 port of SCGCQ01518343)
- pl: NVMe: rapid device removal/add with a specific vendor backplane(SCGCQ01522511 port of SCGCQ01487423)
- pl: backend PCIe: 4311 fault with NVMe enabled (part 2(SCGCQ01523550 port of SCGCQ01523531)
- pl: backend PCIe: non-NVMe endpoint not cleaned up on removal(SCGCQ01529383 port of SCGCQ01516968)
- PL: Fault 0x5862 seen when host buffer size is smaller than allocation length in CDB(SCGCQ01529512 port of SCGCQ01509770)
- PL Fault 0000ecdd LR 01403837 during initial discovery(SCGCQ01539840 port of SCGCQ01531770)
- pl: backend PCIe: switch attached discovery takes too long(SCGCQ01556426 port of SCGCQ01522343)
- (SATA Only) SCSI Unmap command to some SATA drives are timing out(SCGCQ01621120 port of SCGCQ01539572)
- (SATA only) Self-test offline immediate status received from drive is not populated to SCSI log sense command(SCGCQ01713180 port of SCGCQ01681441)
- PL Discovery: After Port Down, Expander Is Not Removed and Firmware Retries SMP Indefinitely(SCGCQ01411982 port of SCGCQ01295414)
- MCTP I2C: I2C traces shows partial response/zero’ed out packet response from the HBA(SCGCQ01421231 port of SCGCQ01394463)
- pl: backend PCIe: ECE4 fault(SCGCQ01434062 port of SCGCQ01312345)
- 0x6004 Fault during TM injection while running IO to Sata SSDs(SCGCQ01437146 port of SCGCQ01416481)
- When disabling one phy of a port the other phys of the same port do not relink after reset(SCGCQ01439512 port of SCGCQ01418575)
- Ventura SBR: Changes to PLL reset requirements cause lock failure on some boards(SCGCQ01440390 port of SCGCQ01373888)
- Customer experiences 5-7 % performance drop on 24 direct connected SAS SSD R10/R6 setup(SCGCQ01442980 port of SCGCQ01417361)
- PL: Change avoid duplicate mid LUN reset option to abort task set(SCGCQ01444118 port of SCGCQ01429655)
- Ventura vSES: SAS and SATA direct attached devices are not getting associated to vSES in Windows Storage Spaces Direct(SCGCQ01451982 port of SCGCQ01438119)
- pl: port enable may fail to complete if an OEM backplane is attached(SCGCQ01467289 port of SCGCQ01455680)
- PL owned mids are not getting released even after removing drives (SATA(SCGCQ01512617 port of SCGCQ00846818)
- Ventura hardware does not like the IOP enable method used here(SCGCQ01519729 port of SCGCQ01514880)
- (SATA Only) LBPRZ bit in VPD page 0xB2 is never set for SATA devices(SCGCQ01524353 port of SCGCQ01516277)
- Controller is not detecting in the storelib, after changing the mode from "set mode oob" command(SCGCQ01530310 port of SCGCQ01494018)
- pl: NVMe: EC0D fault(SCGCQ01533267 port of SCGCQ01530402)
- pl: backend PCIe: link workaround not sufficiently coordinated with SAS link establishment(SCGCQ01556893 port of SCGCQ01540226)
- To implement the CHANGE_DETECT GPIO feature for the UBM backplanes(SCGCQ01628440 port of SCGCQ01507506)
- The PCIe reset to be handled properly for the Change detect feature(SCGCQ01628452 port of SCGCQ01623437)
- PL: Change to Customer Specific SMP Response Report Manufacturer(SCGCQ01639906 port of SCGCQ01505468)
- Not to do all drives reset at the start of the boot up on each port of the controller(SCGCQ01681401 port of SCGCQ01670965)
- PL : performance drop of nearly 40% in sequential write and seqential Reads(SCGCQ01341898 port of SCGCQ01333993)
- pl: NVMe: memory leak in Verify (10/12/16) command translation(SCGCQ01434063 port of SCGCQ01429659)
- 9405W-16i xml not available in Latest Release Order(SCGCQ01434399 port of SCGCQ01429439)
- Customer experiences 5-7 % performance drop on 24 direct connected SAS SSD R10/R6 setup..(SCGCQ01442976 port of SCGCQ01417361)
- Ventura/Marlin: NMI due to Host-side PCE credit starvation when there are simultaneous accesses to MSIX table and Generic Messaging Queue.(SCGCQ01445831 port of SCGCQ01418686)
- Direct attached VSES Enclosure validation may fail with certain OS tools.(SCGCQ01451191 port of SCGCQ01445053)
- PL: EnclMgmt: Move ownership of SES Page 0x0A slot mapping from devices to PHYs.(SCGCQ01458359 port of SCGCQ00870423)
- VSES Target not added in host if event replay slot ordering is enabled(SCGCQ01474945 port of SCGCQ01471601)
- BMC emulator on Ventura failed with Storlib discovery(SCGCQ01488146 port of SCGCQ01410607)
- Enhance SAS3 FW to pass PCIeCV PCIe Configuration Validation TD_1_28 Vital Product Data Capability Test(SCGCQ01499168 port of  SCGCQ00878239)
- Ventura VSES: Unique id and serial number for virtual SES to support microsoft storage spaces direct(SCGCQ01500100 port of SCGCQ01404241)
- pl: backend PCIe: 4311 fault with NVMe enabled(SCGCQ01520574 port of SCGCQ01514521)
- (SATA Only) Security Protocol In command complete without data transfer for allocation length not a multiple of 512(SCGCQ01524638 port of SCGCQ01275335)
- pl: NVMe: PCIe reconfiguration may occur during NVMe controller reset(SCGCQ01527219 port of SCGCQ01526236)
- Fixing the issues during bringup of the universal backplane(SCGCQ01599610 port of SCGCQ01522148)
- Ventura B0: Fault 0x4311 while running HBA phys off/on & drive hard reset(SCGCQ01698231 port of SCGCQ01619417)
- pl: Mode Select translation transfer length validation(SCGCQ01439510 port of SCGCQ01435884)
- Ventura: Misc tri-mode backplane mgmt detection fixes and Slot status update changes(SCGCQ01441077 port of SCGCQ01428718)
- vSES Target: Incorrect Sense Data for REQUEST SENSE Command(SCGCQ01500101 port of SCGCQ01451678)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01530305 port of SCGCQ01450475)
- PL: Port Glitch on Direct Attached SATA drives,lead IO stop/File system become read only(SCGCQ01615056 port of SCGCQ01572062)
- Ventura: NVMe Target: Non-Zero Value in TRACK SKEW FACTOR field of FORMAT DEVICE Mode Page(SCGCQ01444677 port of SCGCQ01412908)
- pl: NVMe: EC26 fault(SCGCQ01453726 port of SCGCQ01451332)
- (VSES) SES INQUIRY commands and storcli commands hang while getting adapter information(SCGCQ01463523 port of SCGCQ01458388)
- Ventura vSES: Direct attached NVME drives are not getting associated with vSES in Microsoft Storage Spaces Direct(SCGCQ01502143 port of SCGCQ01478170)
- To fix issues for back plane configuration validation and LED control for the UBM backplane(SCGCQ01599611 port of SCGCQ01533852)
- IO starvation and performance degradation when using dma Q masking feature(SCGCQ01630921 port of SCGCQ01505074)
- ExtManPage40 FeatureFlags bit definition is missing in 9405W-16i partinal NVDATA(SCGCQ01684232 port of SCGCQ01639482)
- PL: Chassis Slot Valid Flag is Incorrectly Cleared in Enclosure Page 0(SCGCQ01715875 port of SCGCQ01715509)
- PL: Revised "Avoid Duplicate Mid" Feature Code Could Incorrectly Allow IO to Start Through PL Firmware Path(SCGCQ01749480 port of SCGCQ01520524)
- Avoid releasing I2C bus when I2C operation(Read/Write) in progress(SCGCQ01752794 port of SCGCQ01721931)
- Ventura/Marlin: NMI due to Host-side PCE credit starvation when there are simultaneous accesses to MSIX table and Generic Messaging Queue(SCGCQ01448302 port of SCGCQ01418686)
- To fix the phy to slot mapping issue for the UBM backplane(SCGCQ01599612 port of SCGCQ01542497)
- Ventura B0: Slot status LED updates to certain slots on NVMe backplane may fail(SCGCQ01599616 port of SCGCQ01574224)
- Get VDM Support command does not have VendorID and VendorAddInfo fields properly populated(SCGCQ01456658 port of SCGCQ01450475)
- To fix the LED issue, VPP data and moving to change detect poll state( SCGCQ01599614 port of SCGCQ01576165)
- Change detect feature support on UBM supported back plane(SCGCQ01628442 port of SCGCQ01605371)
- Ventura: Disable drive presence based PCIe RefClk and PERST control for OEM ID66 backplane(SCGCQ01676884 port of SCGCQ01670180)
- Hot plugged NVMe drive fails to link up on OEM backplanes with ISTWI drive presence polling enabled(SCGCQ01464097 port of SCGCQ01463496)
- Ventura VSES: Incorrect data in diagnostic page 0xA when drive is missing but not yet removed(SCGCQ01502175 port of SCGCQ01472941)
 - pl: backend PCIe: 4311 fault (part 3)(SCGCQ01574923 port of SCGCQ01537791)
- The x4 link configuration was not detected by UBM module(SCGCQ01747034 port of SCGCQ01735485)


Version 5.01-07-1-1
---------------
Contains:
    BIOS            Firmware      UEFI Driver
    9.9.0.0         5.125.2.0     5.0.0.0


Version 2.08 -  New Function Only/No fixes
---------------
Contains:
  BIOS         Firmware      UEFI Driver
  9.01.03.00   01.125.16.00  01.04.00.00





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2022 Lenovo. All rights reserved

ThinkSystem 430/440 HBA Adapters Driver for sles 15 (For Sles)



12Gb HBA SAS/SATA/SSD Driver for Linux

NOTE TO SERVICE - Reference RETAIN N/A

Supported Controllers: 
 - N2215 SAS/SATA HBA (47C8676)
 - N2225 SAS/SATA HBA (00AE912)
 - N2226 SAS/SATA HBA (00AE916)
 - ThinkSystem 430-8i SAS/SATA 12Gb HBA   (7Y37A01088)        
 - ThinkSystem 430-16i SAS/SATA 12Gb HBA  (7Y37A01089)       
 - ThinkSystem 430-8e SAS/SATA 12Gb HBA   (7Y37A01090)       
 - ThinkSystem 430-16e SAS/SATA 12Gb HBA  (7Y37A01091)        
 - ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA  (NA-StarkSASHBA)  
 - N2125 SAS/SATA Controller (46C9011)
	ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA for 4Y37A09724
	ThinkSystem 440-16i CFF SAS/SATA PCIe Gen4 12Gb Internal HBA for 4Y37A09725
	ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA for SR17A98375
	ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA for SR17A98376 
 - ThinkSystem 1611-8P PCIe Gen4 NVMe Switch Adapter  for  4Y37A09737
 
Supported Kernels: SLES 15.2,15.3

version	39.00.04.00-- Moderate Impact/Low Probability of Occurrence
-----------------------	
Ph20

Defects:
-mpt3sas: Fix - One vSES device addition to OS is missing when two vSES devices are configured in IOC.(DCSG00936126)
-mpt3sas: Fix - SATA queue depth limited maximum to 32 even though HBA firmware sets its more than 32.(DCSG00966032)
-Ph20: Fix structurally dead code reported by Coverity.(DCSG00987309)
-Ph20: Fix Coverity Reported defects:.(DCSG00969837)
-Ph19: Upstream Port : mpt3sas: Do not use GFP_KERNEL in atomic context.(DCSG00935988)
-mpt3sas - Fix the endianness of ActiveCablePowerRequirement while displaying active cable event information.(DCSG00832919)
-Ph22 mpt3sas: Disable Shared Host Tag Support.(DCSG01106634 (Port Of Defect DCSG01106690))
-Kernel panic observed while performing power cycle operation on drives connected to expander.(DCSG01048756 (Port Of Defect DCSG01058120))
-Timestamp is not properly populated.(DCSG01039799 (Port Of Defect DCSG01040695))
-mot3sas: Fix the junk characters that get displayed while printing ChipName.(DCSG00735107 (Port Of Defect DCSG00914072))
-System falls into read only mode while doing firmware downgrade operation.(DCSG01053915 (Port Of Defect DCSG01057285))
-mpt3sas - Fix dma_pool_free PCIe SGL pool (bad dma) messages.(DCSG00837488 (Port Of Defect DCSG00907750))

EnhancementRequests:
-mpt3sas: Gracefully handle HBA firmware fault while scanning the devices during IOC Initialization.(DCSG00428569)
-Ph19: Upstream port: fix ReplyPostFree pool allocation.(DCSG00908392)
-mpt3sas: Add driver support for SLES15SP3 OS.(DCSG00961074)
-Ph20: mpt3sas driver support for RHEL 8.4 OS.(DCSG00944572)
-Add BuildKit Support for RHEL 8.5.(DCSG01076786)
-Ph19: Add OpenEuler 20.03 LTS OS Support.(DCSG00835041)
-mpt3sas: Added support of shared host tagset.(DCSG00707728)
-mpt3sas: add io_uring iopoll support.(DCSG00919665)
-Ph19: Remove logging BIOS version in the kernel log.(DCSG00648679)
-mpt3sas: Gracefully handle HBA Firmware faults during first half of IOC Initialization.(DCSG00757752)
-Add OpenEuler 20.03 SP1 LTS Buildkit support (Driver RPM Binary).(DCSG01004086)
-Port from Upstream: mpt3sas: Move a little data from the stack onto the heap.(DCSG00943359)
-mpt3sas - Use the Firmware recommended device queue depth instead of using hard coded values.(DCSG00939265)
-Ph18: SLES15SP3 RPM WA to create initramfs after rpm installation.(DCSG00990761)
-Ph20: mpt3sas driver support for RHEL 8.5 OS.(DCSG01079682)
-Update OpenEuler buildkit to support x86_64 and aarch64 builds from VBAS.(DCSG01033094)


version	37.00.02.00-- Moderate Impact/Low Probability of Occurrence
-----------------------	
Ph18

Defects:
-mpt3sas: Fix the bug in determining SDD or HDD drive logic.(DCSG00405885)
-Fix some of sparse warnings and warnings from build flag W=1.(DCSG00433486)
-mpt3sas: Return back the UNMAP SCSI command issued to NVMe drives with ILLEGAL_REQUEST sense key if the parameter list length is non zero and less than 24 bytes.(DCSG00317760)
-mpt3sas: Too many virtual_phy objects are allocated even when there is only one vSES is present.(DCSG00405891)
-Address issues from Coverity analyzer..(DCSG00451494)
-mot3sas: Fix the junk characters that get displayed while printing ChipName.()
-mot3sas: Fix the junk characters that get displayed while printing ChipName.(DCSG00735107 (Port Of Defect DCSG00959583).()
-mpt3sas: Fix - One vSES device addition to OS is missing when two vSES devices are configured in IOC.(DCSG00936126 (Port Of Defect DCSG00959573))
-mpt3sas - Fix dma_pool_free PCIe SGL pool (bad dma) messages.(DCSG00837488 (Port Of Defect DCSG00959578))

EnhancementRequests:
-Ph17 : Add Citrix Xenserver 8.2 OS Support.(DCSG00283053)
-mpt3sas: Remove un-used / Pre-production IDs.(DCSG00347011)
-Add BuildKit Support for RHEL 8.4.(DCSG00971809)
-Phase 18: Add Support for OEL UEK kernels 4.14.35.(DCSG00433355)
-Ph18: Add mpt3sas driver support for SLES15 SP3.(DCSG00972769)
-Ph18: Add mpt3sas driver support for RHEL 8.4 OS.(DCSG00971892)
-Ph17: Periodic Time Sync between the Driver and FW.(DCSG00269087)
-mpt3sas: simplified the code section related to refreshing the hba_port table during host reset.(DCSG00412032)
-Ph18: mpt3sas OS driver support for RHEL 8.3.(DCSG00373406)
-Port from Upstream: mpt3sas: a small correction in _base_process_reply_queue.(DCSG00379898)
-Add Driver Signing Flow for Tier 1 Linux OS (SUSE and RHEL) - IT.(DCSG00373449)
-Phase 18 : RHEL 7.9 OS Driver Support.(DCSG00373540)
-mpt3sas: Save the user configured trigger values in driver trigger pages of NVRAM.(DCSG00235944)
-Port from Upstream - mpt3sas: Fix sync irqs.(DCSG00379897)
-Upstream port: mpt3sas: Don't call disable_irq from IRQ poll handler.(DCSG00346997)
-Ph18: SLES15SP3 RPM WA to create initramfs after rpm installation.(DCSG00990761)
-When HTB is released we never know for what reason buffer is released. Need to add that in drivers so that top layers can fetch those information.(DCSG00373439)
-Ph17: SLES15SP2 OS Support.(DCSG00278037)
-Ph18: Assign bit 1 in drv_support_bitmap sysfs parameter as support flag for Additional Diagnostic query ..(DCSG00404493)
-mpt3sas: multi-port path - Set proper PhysicalPort value while issuing the SMPPassthrough request message.(DCSG00244772 (Port Of EnhancementRequest DCSG00283221))
-mpt3sas: Increase IOCIinit request message timeout from 10s to 30s.(DCSG00432754 (Port Of EnhancementRequest DCSG00432880))
-mpt3sas: enable multi-port path support by default on Sea & Ventura devices.(DCSG00249086 (Port Of EnhancementRequest DCSG00283223))
-mpt3sas: Upstream port: fix ReplyPostFree pool allocation.(DCSG00908392 (Port Of EnhancementRequest DCSG00959581))
-mpt3sas: multi-port path support: Handle vSES device separately as it may have same Port ID as other direct attached device Port ID.(mpt3sas: multi-port path support: Handle vSES device separately as it may have same Port ID as other direct attached device Port ID)
-mpt3sas: Add driver support for SLES15SP3 OS.(DCSG00961074 (Port Of EnhancementRequest DCSG00961941))


version	35.00.02.00 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
Fixed:
Update SAS HBA SLES driver to 35.00.02.00, remove raid_class.ko for OSC
mpt3sas - Fix dma_pool_free PCIe SGL pool (bad dma) messages.(DCSG00837488)

version	35.00.01.00 -- Moderate Impact/Low Probability of Occurrence
-----------------------
Ph16

Defects:
-Phase16 - Port Upstream fixes for Reply Pool allocation in NON-RDPQ mode. (Dev Defect).(DCSG00236774)
-mpt3sas: handle the interrupt latency issues while processing the target and LUN reset.(DCSG00244057)
-Fix unwanted messages displaying while using generic src rpm in debian.(DCSG00414316)
-mpt3sas: Don't flush out the outstanding IOs from .remove() in case of ordered HBA removal.(DCSG00055141 (Port Of Defect DCSG00076465))

EnhancementRequests:
-Fix driver compilation issue with 5.5 kernels..(DCSG00071969)
-Ph15 Add SRC RPM support for RHEL 8.2 and Ubuntu 20.04.(DCSG00079352)
-Code Review: Port from upstream and code Review.(DCSG00087135)
-Ph16 mpt3sas: Add RHEL8.3 OS Support.(DCSG00416036)
-Buildkit Update for RHEL8.2.(DCSG00171494)
-Update Buildkit for SLES15SP2.(DCSG00256383)
-Phase 15: Simplify RDPQ DMA allocation.(DCSG00083296)
-mpt3sas: Cancel the running work also while cleaning up works from firmware event work queue.(DCSG00153595)
-mpt3sas: Capture the MPT3SAS_ADAPTER structure data as part of debugging improvement.(DCSG00070290)
-mpt3sas: Dump system registers for debugging.(DCSG00136289)
-Ph18: Update BuildKit to support RHEL8.3.(DCSG00416071)
-Ph16 mpt3sas: According to MPI spec SenseBuffer, Reply, RequestFrame, ReplyFreeQueue & ChainBuffer must satisfy 4GB boundary restriction.(DCSG00165164)
-Ph15: RHEL7.8 Support for SAS35 Phase 15.(DCSG00075087)
-Ph15: Drop sles12sp2 from OS Support list..(DCSG00071973)
-Ph16: mpt3sas OS Driver Support for Ubuntu 20.04.(DCSG00153276)
-Phase 16 : RHEL 7.9 OS Driver Support.(DCSG00379891)
-Ph16: RH 7.8 Support.(DCSG00075094)
-mpt3sas: Memset config_cmds.reply buffer with zeros before issuing config page request.(DCSG00134501)
-IT Linux Phase 16: Add RHEL 8.2 OS support (Kernel - 4.18.0-193.el8.x86_64).(DCSG00171492)
-Ph18: Add RHEL 7.9 Build kit support to generate RPM's and DUD:.(DCSG00373755)
-Linux IT Ph15 mpt3sas: Remove usage of device_busy counter when blk-mq is enabled.(DCSG00070285)
-Ph17: SLES15SP2 OS Support.(DCSG00278037 (Port Of EnhancementRequest DCSG00323616))
-Phase 15: Adding RHEL 8.3 Source RPM support.(DCSG00255944 (Port Of EnhancementRequest DCSG00257350))


version	33.00.01.00 -- Moderate Impact/Low Probability of Occurrence
-----------------------
Linux driver-PH14

Defects:
-Print message for invalid and Tampered modes for AERO adapters.(DCSG00046030)
-Phase14 PA2: Fix Coverity reported uninitialized scalar variable:.(DCSG00039059)
-PH14 Linux Driver: NVMe shutdown Timeout observed for a NVMe drive having latency 0xa.(DCSG00033916)
-PH14 LinuxDriver: NVMe Shutdown latency is not matching with the PCIe device page2 value,after updating the FW from PH13 to PH14.(DCSG00033895)
-Update SLES DUD buildkit.(DCSG00105055)
-PH14 Linux Driver: Warnings encountered during installation of driver source rpm package (DCSG00057923).(DCSG00058099)
-mpt3sas: Don't flush out the outstanding IOs from .remove() in case of ordered HBA removal.(DCSG00055141 (Port Of Defect DCSG00118139))

EnhancementRequests:
-mpt3sas: Optimize Linux Driver logging to have ability to debug from first-time capture.(DCSG00034901)
-Upstream port: scsi: mpt3sas: Mark expected switch fall-through.(DCSG00043171)
-IT Linux AutoBST: Add AutoBST infrastructure for IT Linux driver 'mpt3sas'.(DCSG00060120)
-Sign Source RPMs with GPG publicprivate key.(DCSG00057289)
-Ph14: RHEL 7.8 Support.(DCSG00129150)
-Update Ubuntu Build kit for Ubuntu 20.04.(DCSG00079951)
-Upstream Port: mpt3sas: Select IRQ_POLL to avoid build error.(DCSG00028079)
-Phase 14: Add RHEL 8.2 OS support (Kernel - 4.18.0-193.el8.x86_64).(DCSG00167711)
-mpt3sas: Added module parameter named 'enable_sdev_max_qd' to override sdev queue depth to host's can_queue value.(DCSG00025451)
-Phase 15: Automate SLDPK build and Releases.(DCSG00103269)
-For NVMe devices use RTD3 Entry Latency time as timeout value for nvme shutdown command.(DCSG00026991)
-Ph15 : Add BuildKit suuport for RHEL78.(DCSG00126746)
-Added support for the CoreDump collection on IT-FW fault.(DCSG00027606)
-mpt3sas: developed a phython utility 'decode_ioc_binary_dump.py' to decode the ioc dump collected through debugfs.(DCSG00076209)
-Phase 14: Add SLES12SP5 OS Support.(DCSG00054299)
-IT Linux Phase 14: Add RHEL 8.1 OS support (Kernel - 4.18.0-147.el8.x86_64).(DCSG00047864)
-BuildKit: Sign Source RPMs with GPG publicprivate key.(DCSG00057290)
-Add mpt3sas driver support for Citrix Hypervisor 8.1.(DCSG00065970)
-MPI 2.6: Header file changes associated with Revision 2.6.9 of the specification.(DCSG00024640)
-MPI 2.6: Add additional IOC_State (CoreDump) to allow firmware to dump debug logs without being reset by host.(DCSG00020567)
-Ph15 Add SRC RPM support for RHEL 8.2 and Ubuntu 20.04.(DCSG00079352 (Port Of EnhancementRequest DCSG00118123))



version	32.00.01.00 -- Moderate Impact/Low Probability of Occurrence
-----------------------
Linux driver-PH13

Defects:
-Seagate Linux MPT3SAS Queue Depth limitation.(DCSG00033868)
-mpt3sas : Toolbox memory move write operation is getting failed.(SCGCQ02139652)
-SAS35 Ph12 mpt3sas : Add RHEL 8 OS support.(SCGCQ02129387 (Port Of EnhancementRequest SCGCQ02128161)
-mpt3sas: Reduce the performance dip depth which will be observed on SATA HDD when any ATA PT command is outstanding.(SCGCQ02131946 (Port Of EnhancementRequest SCGCQ02129874))
-mpt3sas: Fix 0x2666 fault observed while rebooting the server.(SCGCQ02114357)
-Linux Driver: RHEL 6: Warning while installing the rpm package.(SCGCQ02117510)
-mpt3sas: Process SAS DEVICE STATUS CHANGE EVENT event from ISR context.(SCGCQ02121829 (Port Of EnhancementRequest SCGCQ02114044))
-Code optimization and src rpm build kit clean up.(SCGCQ02100212)
-mpt3sas: Fix - App own flag is set even when application has not registered the trace buffer.(DCSG00010203)
-mpt3sas:  Fix - don't check for IOC state for fault state & issue diag reset when IOCIinit handshake request failed during host reset.(DCSG00002616)
-Ph13: Ubuntu dkms - Debug Print misspelled.(DCSG00003051)
-mpt3sas: Inbox driver getting loaded after booting into updated RHEL8 kernel.(DCSG00002612)
-Phase 13: Add SLES12SP5 OS Support.(DCSG00055540)

Enhancements:
-mpt3sas: Upstream - add driver support for v5.1 kernel.(SCGCQ02137486)
-mpt3sas: if fault is observed during driver load time then issue diag reset to recover HBA from fault state.(SCGCQ02131954)
- Add Citrix Hypervisor 8.0 driver binary support in Ph12.(SCGCQ02122776)
-Allow Encapsulated NVMe commands through IOCTL for NVMe device which has blocked access status.(SCGCQ02048934)
- mpt3sas: Add driver support for MEMORY MOVE Tool box command issued from application.(SCGCQ02082549)
-Revert (ER SCGCQ01992112 => Enable drivers internal lookup table to track scsi cmd).(SCGCQ02085401)
-Port Upstream fix: Fix kernel panic during expander reset (Fix for scsi_host_find_tag() returning invalid address).(SCGCQ02085406)
-SAS35 Ph11 -Update to MPI 2.6.8 specification and 2.00.54 header files.(SCGCQ02080516)
-Enumerating SES for a managed switch from new PCIe Device type "MPI26_PCIE_DEVINFO_SCSI.(SCGCQ02080567)
- Linux IT Ph12 mpt3sas: Disable high IOPs mode on non-Intel architectures.(SCGCQ02082547)
-Phase 12: Add SLES12SP5 OS Support.(DCSG00056539)
-mpt3sas: fix double-fetch bug in _ctl_ioctl_main().(DCSG00012734)
-Upstream: Port support target smid for [abort|query] task.(DCSG00013488)
-Upstream:  clean up a couple sizeof() uses.(DCSG00013979)
-Add RHEL 7.7 GA OS Support.(DCSG00015325)
-Phase 13 SLES 15 SP1: Driver rpm package naming convention is changed..(DCSG00005502)
-Unifying Host Trace Buffer handling between Linux and Windows Driver.(DCSG00002773)
-mpt3sas: port upstream patch - drivers: Remove explicit invocations of mmiowb().(DCSG00005411)
-Check in MPI 2.6 2.6.9 Headers.(DCSG00005425)
-mpt3sas: Add managed IRQ's support on kernel greater than v5.0.(DCSG00002614)
-mpt3sas: Remove CPU architecture check to decide performance mode.(DCSG00002648)
-mpt3sas: Enable msix_load_balance only when when combined reply queue mode is disabled(DCSG00002721) 
-SLES12SP5 PRE GA OS Support through Source RPM.(DCSG00002775)
-mpt3sas: make driver module parameters visible in sysfs(DCSG00003965)

version	30.00.00.00 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
Linux driver-PH11

defects	
 - Uninstallation of mpt3sas rpm on Citrix6.0 fails with error message "No module mpt3sas found"(SCGCQ00342761) 
 - Device may not be properly offlined or unblocked in some scenarios.(SCGCQ00347498) 
 - Running processes are not getting resumed post hibernation(SCGCQ00395183) 
 - Driver does not load with Invader C0 with DDR enabled and Host Credits set to 30,000.(SCGCQ00395447) 
 - Setting a default value for max_msix_vectors(SCGCQ00448248) 
 - Linux mpt3sas: Installation of mpt3sas driver rpm fails on OEL7.1 OS(SCGCQ00846206) 
 - Linux mpt3sas: Fix wrong size of argument being passed, which is identified by Coverity tool(SCGCQ00881680) 
 - Linux Combined src: Observed compilation errors on RHEL5 and SLES10 kernels(SCGCQ00917411) 
 - Observing Protection fault due to sas device list corruption(SCGCQ00933587) 
 - System crashes while unloading and loading driver with NVMe drive attached(SCGCQ01098644) 
 - Block and unblock messages are not observed when NVMe drive is removed(SCGCQ01124682) 
 - FW Faulted with fault code 0x5861 while running IOs with NVMe Encapsulated Messages(SCGCQ01206566) 
 - Marlin B0: OS crashed while running Diag reset with IOs(SCGCQ01311474) 
 - Buildkit is modified to install Out of box rpm also in '/lib/modules/4.4.0+2/updates' and also RPM naming convention has been changed to match the inbox driver naming convention.(SCGCQ01318375) 
 - Disable ASPM for MPI2 controllers(SCGCQ01329184) 
 - RHEL 6.8 32 Bit is hitting kernel panic after loading Phase5.0 PA-3 Driver for IT Ventura Controller.(SCGCQ01418569) 
 - Update code to free intended memory pool.(SCGCQ01488145) 
 - Memory leak when unloading driver with NVMe flashed SAS35 controller in the system(SCGCQ01497725) 
 - Memory leak, after cable pull and push of SAS/SATA drives with DMD setSCGCQ01509274) 
 - When the volume members are hot removed and added while performing diag reset, the phy disks are not discovered.(SCGCQ00344824) 
 - The RHEL5, RHEL6 and SLES11 OS rpms in FIXID package do not comply to the naming standard(SCGCQ00477885) 
 - Kernel Panic seen while booting the system with blank card.(SCGCQ00574258) 
 - Driver initialization fails after some random iterations of load/unload of mpt3sas driver module(SCGCQ00589083) 
 - Mpt3sas driver initialization fails on Citrix XenServer(SCGCQ00676273) 
 - Linux mpt3sas SRIOV: SATA devices are not visible on the VMs when the base machine OS is RHEL5.x(SCGCQ00730461) 
 - SMP IRQ affinity per CPU is not added on few supported kernels(SCGCQ00731242) 
 - TRI_MODE definition should be removed from mpi header(SCGCQ00834585) 
 - Linux mpt3sas: Fix array compared against '0',which is identified by Coverity tool(SCGCQ00881517) 
 - Linux mpt3sas: Fix Resource leak identified by Coverity tool(SCGCQ00881682) 
 - Linux SAS3: Unable to boot into Fedora22 OS when connected the OS drive behind HBA after installing the driver rpm(SCGCQ00886999) 
 - Initial Ref Tag is incorrect with 4K sector size drives when PI is enabled for (>=3.18 kernels(SCGCQ01015654) 
 - Code Review Defect: The NVMe native PRP construction uses wrong address in couple of places and that needs to be fixed.(SCGCQ01079119) 
 - Linux Ventura IT phase2: Unable to achieve product targets performance numbers with SAS devices(SCGCQ01175998) 
 - Linux SAS35 mpt3sas: Driver load with less HBA queue size while doing multiple driver unload and load operations(SCGCQ01213150) 
 - Print message of driver for Active cable power management, prints incomplete for RHEL6.x(SCGCQ01255499) 
 - call-trace observed on RHEL6.x while unloading driver.(SCGCQ01336601) 
 - Ph4 IT Linux mpt3sas: Observing kernel panic during topology configuration w/ blk-mq enabled(SCGCQ01351060) 
 - Ventura Phase5: OS crash while removing the drives connected to the controller(SCGCQ01386942) 
 - Linux IT SAS3.5 Phase5 mpt3sas: Observing MCE errors while upgrading the Firmware(SCGCQ01440053) 
 - Workaround in driver to post 64bit request descriptor to register at offset 0xC0/0xC4 to avoid hitting HW bug(SCGCQ01514520) 
 - Fix, False timeout prints for ioctl and other internal commands during controller reset.(SCGCQ01555936) 
 - Linux IT Ph9 mpt3sas: Fix Unknown symbol __umoddi3 dependency error while loading the driver(SCGCQ01869644) 
 - Device is Offlined during Disable/Enable of Inter-Expander Phys(SCGCQ00323892) 
 - Linux mpt3sas: port enable is failed during mpt3sas driver loaded with module parameter max_msix_vectors set to 1(SCGCQ00485663) 
 - In certain cases when max_msix_vectors was to set to 8, it is printing -1(SCGCQ00500728) 
 - Synchronization between PF and VF host drivers is missing while performing diag reset operation(SCGCQ00682671) 
 - Port enable event timeout is observed on VF drivers(SCGCQ00711051) 
 - Linux mpt3sas: Kernel Panic while creating filesystem on a drive(SCGCQ00731042) 
 - SAS3.5 Phase 2 Linux Driver : IOs terminate with Ref Tag and Guard errors on NvMe drives .(SCGCQ01206759) 
 - Ensure the connector_name string is NUL-terminated for NVMe devices(SCGCQ01225123) 
 - Linux IT SAS35 Phase3: Firmware Fault 0x5862 seen after connecting drives to Cutlass A1 card(SCGCQ01273339) 
 - Code Review defect: Don't send sync cache and SSU to FW, when pci_error_recovery or adapter_over_temp is set(SCGCQ01341910) 
 - use scsi_internal_device_block_nowait for RHEL distros greater than RHEL7.3(SCGCQ01526190) 
 - Phase 9: Marking transport command as completed though the command is in use.(SCGCQ01829803) 
 - Phase9 Linux Driver:- Include RHEL 7.6 & SLES12SP4 binaries to "28.00.01.00-1"(SCGCQ02035467) 
 - RAID Volume drives have FPE disabled after a Diag Reset.(SCGCQ00330248) 
 - Driver initialization fails after some random iterations of driver load & unload(SCGCQ00551238) 
 - MPI specs mentions Slot field of SAS DVC pg0 is not valid when EnclosureHandle field is zero which is not taken care in code(SCGCQ00588226) 
 - INVALID_STATE ioc status is not handled properly on VFs for SAS IO UNIT Control message.(SCGCQ00701320) 
 - Linux mpt3sas SRIOV: IO''s terminated and 0x2667 fault is observed on VFs while performing diag reset on PF.(SCGCQ00718817) 
 - Linux mpt3sas SRIOV: kernel panic observed while running TMs from VFs(SCGCQ00729497) 
 - Linux mpt3sas: PFA LED was still glowing on Enclosure even when SMART error SATA drive is replaced with good SATA drive(SCGCQ00806442) 
 - Linux mpt3sas: Fix Unused pointer value defect identified by Coverity tool(SCGCQ00881681) 
 - Linux Driver: Sles 11 SP4 beta Driver rpm file names are in wrong format(SCGCQ00888840) 
 - Linux Driver: Partial driver message is displayed when active cable power consumption exception occurs(SCGCQ01025061) 
 - Coverity Linux_mpt3sas Ph2: Missing break in switch((SCGCQ01215510) 
 - Coverity Linux_mpt3sas Ph2: Nesting level does not match indentationSCGCQ01215516) 
 - Coverity Linux_mpt3sas Ph2: Wrong size of argument being passed as parameter to function	(SCGCQ01215534) 
 - Coverity Linux_mpt3sas Ph2: Logically dead code(SCGCQ01216306) 
 - NVMe devices are not visible to user on Big endian systems.(SCGCQ01249933) 
 - Unmap DMA mappings done while building PCIE native SGL(NVMe PRP(SCGCQ01254375) 
 - Linux IT mpt3sas: Fix the defects opened in CC reviews #13767 & #13774 related Dual Path topology support(SCGCQ01266371) 
 - mpt3sas: Avoid sleeping in interrupt context(SCGCQ01329329) 
 - Linux IT sas35 Phase5 mpt3sas: FW events sent before diagnostic reset are not getting cleaned up during reset(SCGCQ01397582) 
 - Ventura: As per MPI spec use Supplemental Reply Post Host Index Register(combined reply queue(SCGCQ01629402) 
 - Default value is not set for prot_capabilities when negative value is given for prot_mask parameter(SCGCQ00485251) 
 - Blocked Devices are made offlined if diag reset is issued at time of unblocking the device.(SCGCQ00493093) 
 - When device unblocked in certain cases, no messages are not seen in the logs regarding device unblock(SCGCQ00664470) 
 - When IOC goes bad, while flushing the IOs, protection info SGLs are not released for DIF IOs.(SCGCQ00664893) 
 - Linux mpt3sas SRIOV: SRIOV support is not enabled on Fedora OS kernels(SCGCQ00736946) 
 - Linux mpt3sas: XenServer 5.5 binaries are missing in the release tar ball(SCGCQ00802063) 
 - Linux mpt3sas: Fix dereference NULL return value defect identified by Coverity tool(SCGCQ00881498) 
 - Linux mpt3sas: Fix Uninitialized scalar variable defect identified by Coverity tool(SCGCQ00881684) 
 - Linux mpt3sas: CPU affinity hint is un-uniformly enabled in case if the number of CPUs are more than MSI-X vectors enabled(SCGCQ00903484) 
 - Asynchronous completion of timedout IO and task abort of timedout IO.(SCGCQ01027851) 
 - Coverity Linux_mpt3sas Ph2: Wrong size of argument being passed as parameter to function(SCGCQ01222482) 
 - Driver fails to load post installation.(SCGCQ01458946) 
 - Fix Timeout value and Reset method used for Target Reset issued on internal command Timeout. (Code Review fix)(SCGCQ01473759) 
 - Linux mpt3sas: System hang when a drive is removed from JBOD on sles11sp3 OS(SCGCQ00426108) 
 - Loading mpt3sas driver hangs on few kernels because of memory alloc failure.(SCGCQ00518874) 
 - End device location is not displayed few times when internal commands fail during device discovery.(SCGCQ00595788) 
 - Kernel panic while issuing LUN reset or target reset during running IOs(SCGCQ00655811) 
 - Remove extra lock being acquired and add RHEL 6.2+ support for host_lockless mode(SCGCQ00682882) 
 - Linux mpt3sas: Wrong description was displayed on the dpkg -l command output on Debian OS's(SCGCQ00828818) 
 - Linux mpt3sas: Fix unchecked return value defect identified by Coverity tool(SCGCQ00881685) 
 - As per MPI26 spec each reply queue set must have 16 reply queues with same upper 32bits of their memory address(SCGCQ01272382) 
 - Updated OEL6_UEK and OEL7_UEK buildkit(SCGCQ01436811) 
 - Controller fault state 265d while loading latest merged driver for SAS2 card(SCGCQ01471650) 
 - Remove logically dead code(SCGCQ01488142) 
 - OS crashes when drives are hot plugged while loading driver(SCGCQ01494556) 
 - Fix compilation error for SLES11(SCGCQ01698115) 
 - Driver compilation fails on latest upstream kernel(>= v4.17(SCGCQ01799543) 
 - Driver goes in infinite retry loop if internally generated REPORT LUN command response jammed with Check condition(SCGCQ00319620) 
 - Reply post queue depth calculation is not as per the MPI2.5 spec.(SCGCQ00322490) 
 - Infinite loops can occur if MPI2_IOCSTATUS_CONFIG_INVALID_PAGE is not returned(SCGCQ00347491) 
 - kernel panic during module load followed by Enclosure removal.(SCGCQ00384772) 
 - Updated SAS3 README.pdf(SCGCQ00434818) 
 - Kernel Panic is seen when issued Diag reset from task management(SCGCQ00654562) 
 - Set the module param allow_drive_spindown to default if invalid values are passed.(SCGCQ00711793) 
 - Linux mpt3sas: Driver rpm for OEL5.11 UEK kernel is not generated in the 7.255.04.00 alpha build.(SCGCQ00783341) 
 - Linux Ventura IT Phase2 : Observing Data Corruption which chaos tool on NVMe drives(SCGCQ01187754) 
 - Linux SAS35 Phase2: Allocate PCIe SGL pool only for SAS35 HBA devices(SCGCQ01204019) 
 - Linux SAS35 IT Ph2: SATA drive will be in blocked state if diag reset occurs while any ATA Passthrough command is outstanding▪(SCGCQ01221454) 
 - Upstream mpt3sas: fix hang on ata passthru commands(SCGCQ01255965)
 - Fixed - Sync cache command failure with hostbyte=DID_NO_CONNECT during driver unload.(SCGCQ01291425) 
 - Driver has to use sense buffer to copy error response for NVMe encapsulated IOCTL commands.(SCGCQ01391926) 
 - Memory leak seen after using storcli and unloading the driver(SCGCQ01479414) 
 - NVMe task management command is not executed as per NVDAT settings(SCGCQ01524245) 
 - SAS3 PH2 Linux: In dkms installation mode the driver loading is not successful on RHEL 5.8 32 bit(SCGCQ00314484) 
 - OVM 3.2.1 OS kernel fails to allocate the memory requested for higher queue depth(SCGCQ00518928) 
 - Used GFP_KERNEL flag instead of GFP_ATOMIC flag while allocating memory for event notification reply data structure at ISR level(SCGCQ00552999) 
 - Linux mpt3sas: Don't block the drive when drive is under device addition process at SML(SCGCQ00846228) 
 - Refcount fw_events and fix unsafe list usage(SCGCQ00933591) 
 - Linux IT SAS3.5 ph3 mpt3sas: Target number for vSES is incremented after host reset(SCGCQ01255996) 
 - Fix for file system going to read-only mode when controller is resetted(SCGCQ01315476) 
 - Fix SAS drives going for Spin Down when module param allow_drive_spindown is set to 3(SCGCQ01337377) 
 - Driver Unload command does not exit when connected drives are disconnected while unloading driver(SCGCQ01403879) 
 - wrong sizeof argument being passed to sizeof(	▪ (SCGCQ01484567) 
 - Code refactor: memory allocation,setting status for incorrect command,accesing dev struct after decrementing its ref count.(SCGCQ01558459) 
 - The log_info constant is supposed to be IOP_LOGINFO_CODE_TASK_TERMINATED rather than the non-sensical 0x1CA86D0(SCGCQ00301838 port of ) 
 - writeq changed back to 64bit pci transfers(SCGCQ00301840 port of SCGCQ00259827) 
 - Staged Device Discovery functionality of driver not working(SCGCQ00305273 port of SCGCQ00282024) 
 - Coexistence of GEN 2 and GEN 3 driver conflicts on OVM 3.0.3(SCGCQ00335262 port of SCGCQ00330431) 
 - Coexistence of GEN 2 and GEN 3 driver conflicts on OVM 3.0.3(SCGCQ00340303 port of SCGCQ00330431) 
 - Add support for configurable Chain Frame Size.(SCGCQ00933600 port of SCGCQ00929253) 
 - Remove unnecessary synchronize_irq(SCGCQ01079113 port of SCGCQ01077560) 
 - Message displayed improperly in var log(device_block failed with return(27(SCGCQ01099928 port of SCGCQ01096464) 
 - Replace #if defined preprocessor used for "ktime_to_ms" function with Kernel version, where "ktime_to_ms" func is defined(SCGCQ01105904 port of SCGCQ01100154) 
 - device_remove_in_progress check is not implemented in IOCTL path(SCGCQ01105910 port of SCGCQ01079361) 
 - Linux mpt3sas: Set sas_phy's negotiated_linkrate sysfs attribute to 12Gbps if corresponding device is 12Gbps device(SCGCQ01105911 port of SCGCQ01100134) 
 - Upstream mpt3sas - Fix warnings exposed by W=1(SCGCQ01179535 port of SCGCQ01154412) 
 - Linux IT Ph14 mpt3sas: Observed kernel panic while performing shutdown operation followed by immediate PCI device hotplug(SCGCQ01380972 port of SCGCQ01348068) 
 - Port Upstream fix: Fix kernel panic during expander reset (Fix for scsi_host_find_tag(SCGCQ02116554 port of SCGCQ02085406) 
 - When staged discovery is enabled, post diag reset, devices get added, removed and then again added with new target ids.(SCGCQ00301851 port of SCGCQ00288449) 
 - ASD diaganostic trigger support fake event needs to change(SCGCQ00301855 port of SCGCQ00269303) 
 - missing delay not getting set during system bootup(SCGCQ00324675 port of SCGCQ00314867) 
 - LSI SAS HBA 6Gb adapters fails Read Capacity 16 command sent to Tape drive(SCGCQ00341420 port of SCGCQ00295267) 
 - Add support for OEL 6.4.(SCGCQ00454977 port of SCGCQ00411878) 
 - device_blocked, handle(0x0027(SCGCQ00571402 port of SCGCQ00481285) 
 - Drives attached to the expander are not discovered(SCGCQ00571418 port of SCGCQ00567801) 
 - Add branding string support for OEM custom HBA's(SCGCQ00637547 port of SCGCQ00566744) 
 - Fixed the defect by adding a check for other LUNS even if LUN0 is offline(SCGCQ00703194 port of SCGCQ00664374) 
 - Driver compiles on 4.4 kernel with no errors(SCGCQ01073774 port of SCGCQ01066197) 
 - Remove usage of 'struct timeval'(SCGCQ01079115 port of SCGCQ01078582) 
 - Upstream mpt3sas - Eliminate conditional locking in mpt3sas_scsih_issue_tm((SCGCQ01179583 port of SCGCQ01154336) 
 - Addition of two events to Active Cable Exception Event Data(SCGCQ01185776 port of SCGCQ01181276) 
 - Upstream scsi: rename SCSI_MAX_{SG, SG_CHAIN}_SEGMENTS and "DEFINE_PCI_DEVICE_TABLE" macro is deprecated.(SCGCQ01203757 port of SCGCQ01198899) 
 - Linux IT Ph14 mpt3sas: Observed kernel panic during HBA hot plug operation just before issuing system shutdown operation(SCGCQ01380973 port of SCGCQ01366025) 
 - Linux IT Ph14 mpt3sas: Poweroff command fails to shutdown the host post surprise removal of controller(SCGCQ01380975 port of SCGCQ01352902) 
 - Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconde(SCGCQ01868047 port of SCGCQ01867387) 
 - Red Hat 6.3 support(SCGCQ00361916 port of SCGCQ00297615) 
 - Added support to issue a Start Stop Unit command (stopping the target(SCGCQ00423262 port of SCGCQ00394200) 
 - Unbalanced reply queue to CPU mapping when max_msix_vectors is set(SCGCQ00448247 port of SCGCQ00448225) 
 - Target Reset Fails during the disk addition(SCGCQ00481890 port of SCGCQ00481268) 
 - Drive is not showing up in the OS after powering on with 9207-8e with Bobcat Expander(SCGCQ00487138 port of SCGCQ00419910) 
 - Component drives of a Volume goes missing once the volume is deleted(SCGCQ00487140 port of SCGCQ00468602) 
 - Linux mpt3sas: Observed kernel panic during driver load time on RHEL5.11 OS(SCGCQ00880259 port of SCGCQ00878516) 
 - Can't get 1MB IO size using mpt2sas driver on OEL UEK or UEK2(SCGCQ00898466 port of SCGCQ00530826) 
 - OS not discovering all drives in dual node configuration(SCGCQ01026842 port of SCGCQ00776162) 
 - Update Initial Ref Tag with correct value for 4K PI drives (kernels < 3.18 (SCGCQ01073780 port of SCGCQ01066189) 
 - Don't overreach ioc->reply_post[] during initialization , which results in "slab-out-of-bounds" dump on final iteration.(SCGCQ01079114 port of SCGCQ01077566) 
 - Avoid mpt3sas_transport_port_add NULL parent_dev(SCGCQ01110265 port of SCGCQ01109669) 
 - Linux : Enclosure Handles are not updated for SAS device during diag reset(SCGCQ01372661 port of SCGCQ01326058) 
 - Linux IT Ph14 mpt3sas: Added Hot-Plug Surprise removal support on IOCs(SCGCQ01383826 port of SCGCQ01341334) 
 - mpt3sas: Disable DIX support by default.(SCGCQ01465762 port of SCGCQ01465665) 
 - Turning-off Log_info available bit in ioc_status for mpi_trigger(SCGCQ00301847 port of SCGCQ00279997) 
 - Fixid Packaging doesn't contain the RPM for SLES10/SLES11(SCGCQ00361981 port of SCGCQ00356161) 
 - Driver does not comply with the updated timing requirements for issuing a Hard Reset.(SCGCQ00361982 port of SCGCQ00316021) 
 - Intelligent Cluster: Linux Kernel Panic on SLES 11.2 with 9201-16e(SCGCQ00376665 port of SCGCQ00356062) 
 - _base_get_ioc_facts: failed going to ready state (ioc_state=0x20000000(SCGCQ00571424 port of SCGCQ00568563) 
 - Fix driver compilation errors on RHEL5 kernels.(SCGCQ01080913 port of SCGCQ01074408) 
 - Increase NVMe device queue depth to remove performance bottleneck in the driver(SCGCQ01316459 port of SCGCQ01305414) 
 - Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01884875 port of SCGCQ01875700) 
 - Add Diagnostic Trigger management and new DiagService Event to Linux Driver(SCGCQ00301829 port of SCGCQ00226997) 
 - Verifying the proper memory allocation for "ioc->chain_lookup" in the function _base_allocate_memory_pools(SCGCQ00301835 port of SCGCQ00249415) 
 - move the scsi_host_put to the right place(SCGCQ00301844 port of SCGCQ00271607) 
 - Diag Service: No triggers events fired for every reboot of system with Co-Existance of CCOH and DaigService(SCGCQ00301846 port of SCGCQ00257763) 
 - Added support for fedora17(SCGCQ00361920 port of SCGCQ00251438) 
 - Added support for CentOS 6.3(SCGCQ00361921 port of SCGCQ00251425) 
 - New Ubuntu12.04 linux OS currenty support(SCGCQ00361924 port of SCGCQ00251411) 
 - Update the usage of the function pci_remove_bus_device(SCGCQ00394683 port of SCGCQ00359149) 
 - SLES 11 SP3 Beta4 Support(SCGCQ00420593 port of SCGCQ00408139) 
 - When a device is in a non-operational state wait for EEH recovery completion before removing the dead IOC function(SCGCQ00425367 port of SCGCQ00399592) 
 - Drive Pull/Insert Issue - START_UNIT timeouts(SCGCQ00483262 port of SCGCQ00481271) 
 - Kernel panic while upgrading the firmware online(SCGCQ00550047 port of SCGCQ00526468) 
 - Host need to complete SCSI command with DID_RESET status instead of DID_SOFT_ERROR under certain conditions.(SCGCQ00694147 port of SCGCQ00693983) 
 - In DIF-TYPE1-IP mode, the APP tag is zero'd on the wire.(SCGCQ00695354 port of SCGCQ00691983) 
 - Linux mpt3sas: Modified the OEM's HBA product name(SCGCQ00788347 port of SCGCQ00787798) 
 - Unable to disable a phy by setting corresponding phy's 'enable' sysfs attribute to zero(SCGCQ00845286 port of SCGCQ00842931) 
 - Linux mpt3sas: Don't block the Enclosure device(SCGCQ00898464 port of SCGCQ00896193) 
 - Synchronize timed-out IO and Task Management functions(such as task_abort & target_reset(SCGCQ01073779 port of SCGCQ01066194) 
 - set num_phys after allocating phy[] space (SCGCQ01110264 port of SCGCQ01109662) 
 - Upstream mpt3sas - Ensure the connector_name string is NUL-terminated(SCGCQ01185771 port of SCGCQ01154419) 
 - Set maximum transfer length per IO to 4MB for VDs(SCGCQ01210393 port of SCGCQ01072631) 
 - DIF Patchs from Oracle(SCGCQ00301830 port of SCGCQ00255629) 
 - Possible deadlock in IOCTL path(SCGCQ00301842 port of SCGCQ00266321) 
 - smp_processor_id(SCGCQ00301843 port of SCGCQ00268580) 
 - Update the usage of the function scsi_internal_device_unblock(SCGCQ00331941 port of SCGCQ00331929) 
 - New Ubuntu11.10 linux OS currenty support(SCGCQ00361922 port of SCGCQ00302125) 
 - Create phase 13 GCA generic point release for OEL UEK R2(SCGCQ00395417 port of SCGCQ00258229) 
 - Driver is using device handle instead of enclosure slot method for clearing of PFA status(SCGCQ00435927 port of SCGCQ00435028) 
 - Linux mpt2sas: Process works from firmware work-queue sequentially(SCGCQ00772791 port of SCGCQ00769798) 
 - Linux mpt2sas: Driver initialization hangs when pci_enable_msix API fails to enable MSIX vector(SCGCQ00773759 port of SCGCQ00760760) 
 -(SCGCQ00933617 port of SCGCQ00926726) 
 - Upstream mpt3sas - Don't spam logs if logging level is 0(SCGCQ01194636 port of SCGCQ01155651) 
 - Ph14 Linux Driver : Active Cable Exception events are logged by driver for attachment of Passive cables.(SCGCQ01210253 port of SCGCQ01205383) 
 - Linux IT Ph14: Enable Active Cable Exception Event for Fury/Invader(SCGCQ01237382 port of SCGCQ01237340) 
 - Linux SAS35 Ph3 : By default disable multipath support for SAS3.5 HBA's too.(SCGCQ01316220 port of SCGCQ01301732) 
 - Not able to update manpage 11 when try to update FW from OS.(SCGCQ01729592 port of SCGCQ01639219) 
 - 2012 source code copyright(SCGCQ00301826 port of SCGCQ00254805) 
 - when async scanning mode is enabled and scanning is in progress devices are removed and their transport layer entries are not removed.(SCGCQ00380178 port of SCGCQ00379998) 
 - Clear PFA Status on SGPIO when PFA Drive is Removed or Replaced.(SCGCQ00423261 port of SCGCQ00392963) 
 - Linux mpt2sas: A new driver module Parameter is added to Enable/Disable EEDP Support(SCGCQ00423263 port of SCGCQ00295288) 
 - Updated the set_affinity.sh to have a support for more than 32 CPU cores systems(SCGCQ00438827 port of SCGCQ00427368) 
 - Update the usage of the function scsi_internal_device_unblock((SCGCQ00462789 port of SCGCQ00461953) 
 - failure at _transport_set_identify and mpt2sas_transport_port_add(SCGCQ00571398 port of SCGCQ00497017) 
 - Add branding string support for OEM custom HBA's(SCGCQ00871877 port of SCGCQ00867336) 
 - Remove SRIOV specific code from mpt3sas driver and update buildkits accordingly.(SCGCQ01203756 port of SCGCQ01197731) 
 - RHEL7.x: Crash occurred while loading mpt3sas driver with module parameter smp_affinity_enable set to 0(SCGCQ01504666 port of SCGCQ01496368) 
 - Driver sets queue_depth=254(SAS_QUEUE_DEPTH(SCGCQ01763013 port of SCGCQ01741671) 
 - driver oops associated with the max_queue_depth command line option set too small(SCGCQ00301837 port of SCGCQ00258989) 
 - Providing a negative value to sdev_queue_depth parameter leads to incorrect queue depth for a SAS drive.(SCGCQ00301848 port of SCGCQ00279155) 
 - Linux driver : updated initrd.img doesn't contain newly installed mpt2sas driver module(SCGCQ00332653 port of SCGCQ00332288) 
 - Debian6.0.5 Linux Support for 32 and 64 bit(SCGCQ00361923 port of SCGCQ00251412) 
 - Add support for OEL 6.3.(SCGCQ00361926 port of SCGCQ00303161) 
 - Oracle Linux 5.9 Support(SCGCQ00454974 port of SCGCQ00401299) 
 - Linux mpt2sas: Added support for OVM3.2.1 OS(SCGCQ00454976 port of SCGCQ00411913) 
 - Kernel Panic observed after issuing controller diag reset.(SCGCQ00526798 port of SCGCQ00501333) 
 - Only 8 MSIX vectors are enabled for SAS3 HBAs on a 32 core machine(SCGCQ01107215 port of SCGCQ01106942) 
 - Missing curly braces on if statement to print message when there is insufficient power for active cable.(SCGCQ01110263 port of SCGCQ01109643) 
 - Upstream mpt3sas - Eliminate dead sleep_flag code.(SCGCQ01179606 port of SCGCQ01154385) 
 - DID_SOFT_ERROR issue encountered on SATA RAID1 during testing 12.100.00.00(SCGCQ01284610 port of SCGCQ01284381) 
 - Linux mpt3sas: Enumeration of drives for OEM specific controller(SCGCQ01408565 port of SCGCQ01318421) 
 - IO Timeouts observed while running IO and parallel TaskMgmt test with SATA drives(SCGCQ01522289 port of SCGCQ01497972) 
 - mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is going on(SCGCQ01827523 port of SCGCQ01819327) 
	
EnhancementRequests 	
 - Change Diagnostic Toolbox CLI SGL format to IEEE (to match MPI 2.5.1 spec change(SCGCQ00314987) 
 - Added mpt3sas driver support for fedora18 OS(SCGCQ00442462) 
 - Added code to display Location of End Device.(SCGCQ00452326) 
 - Added UEK3 (v3.8.13-16)(SCGCQ00552232) 
 - Oracle Linux 5.10 Support(SCGCQ00552253) 
 - Added mpt3sas driver support for Citrix 6.2 OS(SCGCQ00552276) 
 - Added support for Ubuntu14.04(SCGCQ00661419) 
 - Added CENTOS7.0 (x86_64(SCGCQ00675458) 
 - Updating the device removal handshake protocol only on VF drivers(SCGCQ00696568) 
 - Add branding string support for OEM custom HBA's(SCGCQ00718659) 
 - Update upstream Linux mpt3sas: [PATCH] block: Kill bio_segments(SCGCQ00778584) 
 - Update upstream Linux mpt3sas: [PATCH] [SCSI] mpt3sas: remove unused variables(SCGCQ00778631) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's(SCGCQ00793599) 
 - Linux combined src: Disable temperature fault functionality for SAS2 HBA's(SCGCQ00915064) 
 - Linux SAS3.5 phase2 IT: Added support for UNMAP commands for NVMe drives via fast-path(SCGCQ01190581) 
 - Merge MPI end point linux driver to Phase3 sas35 mainline and later to upstrea(SCGCQ01224602) 
 - Pre-allocate RDPQ Array at driver boot time(SCGCQ01297392) 
 - Driver support for OEL 7.4_UEK (4.1.12-94.3.9.el7uek(SCGCQ01396745) 
 - OS driver support for Oracle Linux 7.5 - SAS3 PH 16, SAS3.5 Ph 8(SCGCQ01586104) 
 - Call t10_pi_ref_tag for RHEL 8 kernels(SCGCQ02069530) 
 - Test Unit Ready retries causes slow discovery(SCGCQ00406610) 
 - Added RHEL5.10 support(SCGCQ00442446) 
 - Added mpt3sas driver support for Centos 6.5 OS(SCGCQ00571454) 
 - Addnew module parameter to allow /disallow host driver to issue SCSI commands to bring up drive.(SCGCQ00609923) 
 - Added support for OVM 3.3.1(SCGCQ00666996) 
 - Linux mpt3sas: Porting upstream patches to mainline(SCGCQ00825572) 
 - OS Driver Support for Ubuntu 15.04(SCGCQ00826237) 
 - Fedora 22 OS Support is added(SCGCQ00846536) 
 - Linux mpt3sas_Phase 10 PA#1: Dropping support for RHEL5 and SLES10 distro and Unified binary support for RHEL,OEL & CentOS.(SCGCQ00864228) 
 - Linux combined src: Added mpt2sas driver definitions to combined driver src(SCGCQ00914998) 
 - MPI header update with new supported controller addition(SCGCQ01064186) 
 - Interim Experimental Change: Add code to detect Non first page unaligned SGE for NVMe drives and panic.(SCGCQ01080920) 
 - 0001 - mpt3sas: set default value for cb_idx(SCGCQ01300828) 
 - 0006 - mpt3sas: always use first reserved smid for ioctl passthrough and second reserved smid for internal scsi io commands(SCGCQ01300840) 
 - Report Package Version from HBA Driver(SCGCQ01445879) 
 - Skip pending I/Os issued to NVMe drives while processing Broadcast Async Event(SCGCQ01558613) 
 - mpt3sas: Do not wait for IOC to become operational if HBA is unplugged(SCGCQ01681422) 
 - OS driver support for XenServer7.4 SAS3 PH 16, SAS3.5 Ph 8(SCGCQ01750033) 
 - Linux IT Ph9 mpt3sas: Added mpt3sas driver support for SLES15 OS(SCGCQ01828337) 
 - mpt3sas: Ph9 - Add OEL 6.10 support(SCGCQ01870215) 
 - Modified the SAS3 Linux Driver such that the SAS2 and SAS3 drivers can co-exist.(SCGCQ00300298) 
 - Added Red Hat 5.9 support(SCGCQ00377019) 
 - Added mpt3sas driver support for Citrix 6.1 OS(SCGCQ00442454) 
 - Add support to MPI - ReplyDescriptorPostQueueArray defined in IOC Init Request Message(SCGCQ00467389) 
 - Add branding string support for Intel custom HBA's(SCGCQ00546703) 
 - Added SLES12 RC3 support ( only x86_64)(SCGCQ00672325) 
 - Provide an option to enable / disable spin down SSD and HDD devices while unloading driver.(SCGCQ00695289) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's(SCGCQ00780483) 
 - Added SLES12 GM Support (only X86_64(SCGCQ00785459) 
 - Linux mpt3sas: Make use of additional HighPriorityCredit number of message frames for sending SCSI IO's(SCGCQ00899842) 
 - Linux combined src: Don't print Enclosure level and connector name information for SAS2 HBA's(SCGCQ00915060) 
 - Linux combined src: Disable mapping of SAS devices to VFs SRIOV feature for SAS2 HBA's(SCGCQ00915109) 
 - Linux combined src: Retain same module parameters names which were their before for mpt2sas driver(SCGCQ00916328) 
 - Linux IT/IR: Merge mpt2sas driver in to mpt3sas driver module.(SCGCQ00955258)
 - Linux SAS3.5 IT: Limit 0x2100 FW fault by updating host index up on reaching the thresh hold value(SCGCQ01149963) 
 - Linux SAS3.5 IT Ph2: Block the drive after recieving any ATA pass-though command for that driver and unblock it after completion of the command(SCGCQ01218960) 
 - 0007 - mpt3sas: lockless command submission(SCGCQ01300843) 
 - 0009 - mpt3sas: Enable tag support for all supported kernels	(SCGCQ01300853) 
 - Upstream mpt3sas: Fix memory allocation failure test in 'mpt3sas_base_attach(SCGCQ01454958) 
 - Upstream mpt3sas: scsi_transport_sas: switch to bsg-lib for SMP passthrough(SCGCQ01606945) 
 - Upstream mpt3sas: Fix function prototypes for module_param_call(SCGCQ01607482) 
 - Added support for Atlas Gen4 PCIe switches in MPT driver environments for Linux.(SCGCQ01731329) 
 - Upstream: Added an i/o barrier(SCGCQ01828734) 
 - Updated the build kits to support SAS2 Phase 14 level(SCGCQ00300292) 
 - Added SLES11 SP3 OS support(SCGCQ00454992) 
 - Add support to log message when Temperature Threshold exceeds for any Sensor.(SCGCQ00604649) 
 - Performance improvement by changing Affinity change and adding Host lock less mode(SCGCQ00610127) 
 - Added support for Ubuntu13.0(SCGCQ00614076) 
 - Add branding string support for custom HBA's(SCGCQ00636608) 
 - Added RHEL7.0 support(SCGCQ00672310) 
 - Added OEL7.0 Support(SCGCQ00673317) 
 - Linux mpt3sas: Detect the SMART Error SATA drive in the Topology and turn on it's corresponding PFA LED(SCGCQ00791340) 
 - Added SLES11sp4 GM Support(SCGCQ00826215) 
 - Added UEK3 Update5 (v3.8.13-68(SCGCQ00826232) 
 - Adding Intruder specific code to the Gen3 Linux Phase 9 driver(SCGCQ00831649) 
 - Debian 8.0 OS support-SAS3 Phase 10(SCGCQ00856661) 
 - Linux combined src: For an IO, build MPI SGL LIST for SAS2 HBA's and build IEEE SGL LIST for SAS3 HBA's(SCGCQ00915044) 
 - Linux combined src: Don't send PHYDISK_HIDDEN Raid Action request on SAS2 HBA's(SCGCQ00915050) 
 - Linux combined src: Disable DIX feature specific code for SAS2 HBA's(SCGCQ00915061) 
 - Linux combined src: Disable Target mode hooks from combined driver src(SCGCQ00915067) 
 - Prevent sending I/Os with NVMe PRP if non first page unaligned SGE is detected(SCGCQ01080930) 
 - Linux SAS3.5 Ph2: Enable DIX support(SCGCQ01200312) 
 - Linux SAS3.5 IT Ph2: Set NVMe device queue properties in such a way to reduce holes in sges(SCGCQ01224810) 
 - Added support for XenServer 7.1.(SCGCQ01289850) 
 - 0005 - mpt3sas: Introduce mpt3sas_get_st_from_smid(SCGCQ01300838) 
 - 0008 - mpt3sas: create separate lookup table for NVMe PRP list(SCGCQ01300851) 
 - Optimize I/O memory consumption in driver(SCGCQ01388190) 
 - Enhanced handling of DMA allocation, If the allocation does not fit within same 4GB(SCGCQ01388961) 
 - Upstream mpt3sas: Create two versions of scsi_internal_device_unblock((SCGCQ01447644) 
 - Upstream mpt3sas: fix format overflow warning(SCGCQ01454955) 
 - Added support for RHEL7.5 GA (3.10.0-862.el7(SCGCQ01719072) 
 - Linux IT Phase9 mpt3sas: Ignore processing of Phy having target not responding reason code while processing re-queued event(SCGCQ01892634) 
 - Linux IT Phase9 mpt3sas: Enable PCIe switch enumeration by default for all kernel versions(SCGCQ02018676) 
 - Added DIX support of the Linux operating system to the driver.(SCGCQ00262891) 
 - Add 96 MSI-X vector support for Invader C0(SCGCQ00371782) 
 - Added mpt3sas driver support for fedora19 OS(SCGCQ00552267) 
 - Added UEK3 Update3 (v3.8.13-44(SCGCQ00675434) 
 - Target Numbers of mapped drives on VFs won't increase after diag reset on PF	(SCGCQ00689554) 
 - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago(SCGCQ00729462) 
 - Linux combined src: Defined 'hba_mpi_version_belonged' IOC variable to differnate the each gerenation HBA's specific functionalities(SCGCQ00915025) 
 - Linux combined src: Remove SCSI_MPT3SAS_LOGGING entry from Kconfig files	▪ (SCGCQ00915035) 
 - RHEL 7.3 OS Support for SAS3.5 Phase 2(SCGCQ01218181) 
 - Added mpt3sas driver support for OEL6.9(SCGCQ01289003) 
 - 0003 - mpt3sas: separate out _base_recovery_check(SCGCQ01300833) 
 - Reducing the number of times enclosure config page read request sent by driver(SCGCQ01357382) 
 - Increase event log buffer to support 24 port HBA's to avoid buffer overflow.(SCGCQ01368517) 
 - NVMe Task Management - Controller Reset Support (SCS(SCGCQ01445901) 
 - Upstream: mpt3sas: clarify mmio pointer types (Fix compiler warning(SCGCQ01686081) 
 - Phase8: Fix sparse warnings of inhouse mpt3sas driver.(SCGCQ01729697) 
 - SAS3.5 Phase9: Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL(SCGCQ01828339) 
 - Upstream: Fix _transport_smp_handler(SCGCQ01828766) 
 - Use t10_pi_ref_tag and compatible _transport_smp_handler API in SLES15SP1(SCGCQ02070829) 
 - Added mpt3sas driver support for RHEL 6.5 OS(SCGCQ00552245) 
 - Added OEL6.5 Support(SCGCQ00552260) 
 - Added UEK3 U1 (v3.8.13-26(SCGCQ00571510) 
 - Added SRIOV support for both Xen and KVM hypervisor.(SCGCQ00627105) 
 - Added UEK3 Update2 (v3.8.13-35(SCGCQ00654016) 
 - Added RHEL 6.6 Support(SCGCQ00675448) 
 - Remove kernel support older than N-3 kernel updates, where N is latest kernel update release.(SCGCQ00696790) 
 - Updated MPI 2.5 Release: MPI 2.5 Rev K (2.5.6(SCGCQ00709717) 
 - Added Oracle Linux 5.11 Support(SCGCQ00775653) 
 - Update upstream Linux mpt3sas: [PATCH] mpt3sas: Use pci_enable_msix_exact(SCGCQ00776753) 
 - Update upstream Linux mpt3sas: [PATCH] block: Convert bio_for_each_segment(SCGCQ00778582) 
 - Added UEK3 Update4 (v3.8.13-55(SCGCQ00788014) 
 - Linux mpt3sas: Add branding string support for OEM custom HBA's.(SCGCQ00793614) 
 - Linux SAS3: Add RHEL 6.7 GA Support(SCGCQ00848126) 
 - Linux combined src: Manage MSI-X vectors according to HBA device type(SCGCQ00915056) 
 - Linux combined src: Add OEM's SAS2 HBA's PnP ID Branding names(SCGCQ00915065) 
 - Active cable exception handling in mpt3sas driver:(SCGCQ01008402) 
 - Ventura IT Linux Driver: Update MPI 2.6.07 specification, and 2.00.45 header files(SCGCQ01133212) 
 - Reduce memory footrpints in kdump kernel.(SCGCQ01237163) 
 - 0004- mpt3sas: open code _scsih_scsi_lookup_get(SCGCQ01300836) 
 - Added mpt3sas driver support for RHEL6.9	(SCGCQ01316324) 
 - Added support for SAS Device Discovery Error Event.(SCGCQ01354911) 
 - Upstream mpt3sas: Split scsi_internal_device_block(SCGCQ01447640) 
 - mpt3sas: Added new thread called hot plugged watchdog which will poll for whether HBA device is unplugged or not(SCGCQ01681425) 
 - Linux Drivers: MPI2.5 Update Rev U (2.0.26(SCGCQ00304398) 
 - Added Debian7.0 Linux OS Support(SCGCQ00552280) 
 - Added mpt3sas driver support for fedora20(SCGCQ00571464) 
 - Updated MPI 2.5 Release: MPI 2.5 Rev J (2.5.5(SCGCQ00653281) 
 - Added OEL6.6 Support(SCGCQ00721141) 
 - Added RHEL5.11 Support(SCGCQ00775576) 
 - Update upstream Linux mpt3sas: [PATCH] mpt3sas: delay scsi_add_host call to work with scsi-mq(SCGCQ00778620) 
 - Linux mpt3sas: Added mpt3sas driver support for RHEL7.1 OS(SCGCQ00787975) 
 - Linux Mpt3sas SRIOV: Use serial number as primary key to uniquely identify the SATA drives in device persistence mapping mode(SCGCQ00813146) 
 - Linux mpt3sas: Added mpt3sas driver support for OEL7.1 OS (SCGCQ00838951) 
 - Ph 11 LINUX_MPT3SAS : Dropping support for few distros as per MR OS_Support matrix.(SCGCQ00900247) 
 - Linux conbined src: Move Gen3 HBA's device registration with PCI, SML and IOCTL API's to separate mpt3sas_module.c file(SCGCQ00915016) 
 - Linux Combined src: Added csmi hooks and it will be enabled only for SAS2 HBA's(SCGCQ00915063) 
 - SLES 12 SP2 OS Support for SAS3.5 Phase 2(SCGCQ01154063) 
 - Linux Ventura Phase2: Add support for IO Unit Control, Shutdown message(SCGCQ01165691) 
 - Linux SAS35 IT: Added driver support for Dual/multi-path typologies(SCGCQ01237381) 
 - 00010 - mpt3sas: allocate as many chains as needed and remove chain list maintenance overhead(SCGCQ01300854) 
 - Ph5 : SLES12 SP3(4.4.73-5(SCGCQ01396754) 
 - Linux IT Phase9 mpt3sas: Enable irq poll in Linux driver to avoid CPU hard and soft lockups(SCGCQ01571359) 
 - mpt3sas: code refactor - move section of code which waits for IOC to be in operational state into a separate function(SCGCQ01681420) 
 - Linux IT Phase9 mpt3sas: Added driver support for Ambrosia NVMe Switch Adapter(SCGCQ01891714) 
 - Added Red Hat 6.4 support(SCGCQ00376609) 
 - Added mpt3sas driver support for Centos 6.4 OS(SCGCQ00552285) 
 - When the IOC over heats, driver needs to flush the IOs and panic.(SCGCQ00654911) 
 - When memory allocation for SCSI command message frame request tracker queue fails, driver should be capable lowering the queue depth and allocate memory.(SCGCQ00693434) 
 - VF drivers doesn't need to retrieve the BIOS pages(SCGCQ00698258) 
 - 3008 IT: Add OEM String to Driver for OEM Board Design(SCGCQ00860516) 
 - Linux mpt3sas: Include changes of MPI 2.5 Rev M and MPI 2.6 Rev E specifications and 2.00.39 headers(SCGCQ00899809) 
 - Linux combined src: Disabled SATA SMART polling feature for SAS2 HBA's(SCGCQ00915058) 
 - Linux combined src: Ported WarpDrive HBA support from mpt2sas driver src(SCGCQ00922147) 
 - Linux Combined src: Ported fix for setpci reset kernel oops from mpt2sas src(SCGCQ00922149) 
 - OEL 7.3 OS Support for SAS3.5 Phase 2(SCGCQ01154077) 
 - Linux IT mpt3sas: Recognize and act on IO's iopriority info(SCGCQ01237164) 
 - 0002 - mpt3sas: use list_splice_init(SCGCQ01300832) 
 - Upstream mpt3sas: switch to pci_alloc_irq_vectors(SCGCQ01367469) 
 - Upstream mpt3sas: fix dma_addr_t casts(SCGCQ01541636) 
 - Added support for XenServer 7.3 OS.(SCGCQ01554011) 
 - OS Driver Support for Ubuntu 18.04- SAS3.5 PH 8 / SAS3 PH 16	(SCGCQ01586127) 
 - Upstream mpt3sas: Do not mark fw_event workqueue as WQ_MEM_RECLAIM.(SCGCQ01686075) 
 - mpt3sas: wait for and flush running commands on shutdown/unload (Upstream Patch(SCGCQ01686096) 
 - Change attribution language from Avago to Broadcom and update copyright end year(SCGCQ01757358) 
 - Upstream: Introduced struct "mpt3sas_nvme_cmd"(SCGCQ01828741) 
 - Add RHEL 8 OS driver support(SCGCQ02136688) 

version	28.00.03.00	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
Linux driver-PH9

defects:
- Driver load fails on big endian systems (SPARC64).(SCGCQ01836661)
- Linux IT Ph9 mpt3sas: Fix Unknown symbol __umoddi3 dependency error while loading the driver(SCGCQ01869644)
- Phase 9: Marking transport command as completed though the command is in use.(SCGCQ01829803)
- Phase9 Linux Driver:- Include RHEL 7.6 & SLES12SP4 binaries to "28.00.01.00-1".(SCGCQ02035467)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconds(SCGCQ01868047 port of SCGCQ01867387)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL(SCGCQ01856662 port of SCGCQ01784898)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout
>= 512 seconds(SCGCQ01868049 port of SCGCQ01867387)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is
going on(SCGCQ01905582 port of SCGCQ01819327)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x
vectors on > 16 logical CPU machine(SCGCQ01906874 port of SCGCQ01473904)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01905585 port of SCGCQ01875700)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is
going on(SCGCQ01827523 port of SCGCQ01819327)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode(SCGCQ01884875 port of SCGCQ01875700)
 - Port Upstream fix: Fix kernel panic during expander reset (Fix for scsi_host_find_tag() returning invalid
address)(SCGCQ02116554 port of SCGCQ02085406)

EnhancementRequest:
- Added support for Atlas Gen4 PCIe switches in MPT driver environments for Linux..(SCGCQ01731329)
- Upstream: Added an i/o barrier.(SCGCQ01828734)
- SAS3.5 Phase9: Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD.()
for RHEL, SLES and OEL.(SCGCQ01828339)
- Upstream: Fix _transport_smp_handler() error path.(SCGCQ01828766)
- Upstream: Introduced struct "mpt3sas_nvme_cmd".(SCGCQ01828741)
- Linux IT Ph9 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01828337)
- Linux IT Phase9 mpt3sas: Enable irq poll in Linux driver to avoid CPU hard and soft lockups.(SCGCQ01571359)
- mpt3sas: Ph9 - Add OEL 6.10 support.(SCGCQ01870215)
- Linux IT Phase9 mpt3sas: Ignore processing of Phy having target not responding reason code.()
while processing re-queued event.(SCGCQ01892634)
- Linux IT Phase9 mpt3sas: Added driver support for Ambrosia NVMe Switch Adapter.(SCGCQ01891714)
- Linux IT Phase9 mpt3sas: Enable PCIe switch enumeration by default for all kernel versions.(SCGCQ02018676)
- Call t10_pi_ref_tag for RHEL 8 kernels.(SCGCQ02069530)
- Use t10_pi_ref_tag and compatible _transport_smp_handler API in SLES15SP1.(SCGCQ02070829)



version	27.125.01.00-1	 -- Moderate Impact/Low Probability of Occurrence
-----------------------	
IR/IT (MPT3) – Ph 16 (new)

Defects
- Driver load fails on big endian systems (SPARC64).(SCGCQ01836661)
- Fix, False timeout prints for ioctl and other internal commands during controller reset.(SCGCQ01555936)
- Ventura: As per MPI spec use Supplemental Reply Post Host Index Register(combined reply queue) when MSI-X vectors > 16.(SCGCQ01629402)
- Fix compilation error for SLES11.(SCGCQ01698115)
- Driver compilation fails on latest upstream kernel(>= v4.17), due to changes in "queue_flag_set_unlocked" API.(SCGCQ01799543)
- Code refactor: memory allocation,setting status for incorrect command,accesing dev struct after decrementing its ref count.(SCGCQ01558459)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01615533 port of SCGCQ01473904)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01856662 port of SCGCQ01784898)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)
- Linux IT phase7 mpt3sas: Increase the IOCTL timeout to support the IOCTL commands having timeout >= 512 seconds.(SCGCQ01868049 port of SCGCQ01867387)
- mpt3sas: Lock access to the HBA's PCI config space from user space while Diag reset operation is going on.(SCGCQ01905582 port of SCGCQ01819327)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01729592 port of SCGCQ01639219)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01763013 port of SCGCQ01741671)
- Linux IT SAS3.5 Ph7 mpt3sas: Support for Kernel 4.15 via DDA PT mode.(SCGCQ01905585 port of SCGCQ01875700)
- Linux IT SAS3.5 mpt3sas: Observed hard lockups with SAS35 card which are configured with 16 MSI-x vectors on > 16 logical CPU machine.(SCGCQ01906874 port of SCGCQ01473904)

EnhancementRequests:
- OS driver support for Oracle Linux 7.5 - SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01586104)
- Added support for RHEL6.10 GA(2.6.32-754.el6).(SCGCQ01828835)
- Skip pending I/Os issued to NVMe drives while processing Broadcast Async Event.(SCGCQ01558613)
- mpt3sas: Do not wait for IOC to become operational if HBA is unplugged.(SCGCQ01681422)
- OS driver support for XenServer7.4 SAS3 PH 16, SAS3.5 Ph 8.(SCGCQ01750033)
- Upstream mpt3sas: scsi_transport_sas: switch to bsg-lib for SMP passthrough.(SCGCQ01606945)
- Upstream mpt3sas: Fix function prototypes for module_param_call(SCGCQ01607482)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01719072)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Upstream: mpt3sas: clarify mmio pointer types (Fix compiler warning).(SCGCQ01686081)
- Phase8: Fix sparse warnings of inhouse mpt3sas driver.(SCGCQ01729697)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- mpt3sas: Added new thread called hot plugged watchdog which will poll for whether HBA device is unplugged or not.(SCGCQ01681425)
- mpt3sas: code refactor - move section of code which waits for IOC to be in operational state into a separate function.(SCGCQ01681420)
- Linux IT Ph6 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01839348)
- Upstream mpt3sas: fix dma_addr_t casts.(SCGCQ01541636)
- Added support for XenServer 7.3 OS.(SCGCQ01554011)
- OS Driver Support for Ubuntu 18.04- SAS3.5 PH 8 / SAS3 PH 16.(SCGCQ01586127)
- Upstream mpt3sas: Do not mark fw_event workqueue as WQ_MEM_RECLAIM.(SCGCQ01686075)
- mpt3sas: wait for and flush running commands on shutdown/unload (Upstream Patch).(SCGCQ01686096)
- Change attribution language from Avago to Broadcom and update copyright end year.(SCGCQ01757358)
			 
			 
version	25.125.03.00	 -- Moderate Impact/Low Probability of Occurrence
----------------------
initial release
			 
EnhancementRequests (4)
- Added support for RHEL6.10 GA(2.6.32-754.el6).(SCGCQ01828835)
- Intel Spectre Vulnerability - Add support for retpoline in driver RPM and DUD for RHEL, SLES and OEL.(SCGCQ01784898)
- Added support for RHEL7.5 GA (3.10.0-862.el7).(SCGCQ01749948)
- Linux IT Ph6 mpt3sas: Added mpt3sas driver support for SLES15 OS.(SCGCQ01839348)
- Driver sets queue_depth=254(SAS_QUEUE_DEPTH) and reports tagged(1) when both CMDQUE and BQUE bits set to zero for SES devices.(SCGCQ01789379 port of SCGCQ01741671)
- Not able to update manpage 11 when try to update FW from OS.(SCGCQ01789377 port of SCGCQ01639219)		 





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2022 Lenovo. All rights reserved

LSI Storage Authority Software (For Linux)



LSI Storage Authority Software

Supported controllers:
	ThinkSystem RAID 530-8i PCIe 12Gb Adapter  (7Y37A01082)
	ThinkSystem RAID 530-4i Flex Adapter       (7M17A03932)
	ThinkSystem RAID 530-4i Flex Adapter       (7M27A03918)
	ThinkSystem RAID 530-8i Dense Adapter      (SD530 RAID)
	ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727)
	ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr  (4Y37A78834)
	ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter   (4Y37A78835)
	ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728
	ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729
	ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730
	ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733
	ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735
	ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter  (7Y37A01083)
	ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter  (4Y37A09722)
	ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter  (7Y37A01084)
	ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085)
	ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086)
	ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter  (7Y37A01087)
	ThinkSystem  RAID 930-4i 2GB Flash Flex Adapter      (7M17A03933)
	ThinkSystem  RAID 930-4i 2GB Flash Flex Adapter      (7M27A03917)
	ThinkSystem  RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721)
	ServeRAID M1210 SAS/SATA Controller    (00JY194)
	ServeRAID M1215 SAS/SATA Controller    (46C9114)
	LSI SAS3004 RAID                       (NA-SAS3004-B)
	LSI SAS3004 RAID                       (NA-SAS3004-N)
	ServeRAID M5210 SAS/SATA Controller    (46C9110)
	ServeRAID M5225-2GB SAS/SATA Controller(00AE938)
	ServeRAID M5215 with 2GB Flash Enablement Flex System x240 M5   (00JX142)
	ServeRAID M5210e SAS/SATA Controller   (46C9117CTO)
	ThinkSystem 430-8i SAS/SATA 12Gb HBA   (7Y37A01088)
	ThinkSystem 430-16i SAS/SATA 12Gb HBA  (7Y37A01089)
	ThinkSystem 430-8e SAS/SATA 12Gb HBA   (7Y37A01090)
	ThinkSystem 430-16e SAS/SATA 12Gb HBA  (7Y37A01091)
	ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA  (NA-StarkSASHBA)
	ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA for 4Y37A09724
	ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA for 4Y37A09725
	N2215 SAS/SATA HBA   (47C8675)
	N2225 SAS/SATA HBA   (00AE912)
	N2226 SAS/SATA HBA   (00AE916)

Support OS:
            - SLES 12 SP3, SLES 12 SP4, SLES 12 SP5, 
			- SLES 15 SP1, SLES 15 SP2, SLES 15 SP3, 
			- Ubuntu 18.04 LTS, Ubuntu 18.04.5, 
            - RHEL 7.7,7.8,7.9
			- RHEL 8.1/8.2/8.3
            - ESXi 6.7 U1/U2/U3, ESXi 7.0, ESXi 7.0 U1.
			
007.020.014.000 - Moderate Impact
---------------
MR 7.20

Defects:
 Fixed :LSA set lane speed to 16GT/s(DCSG01111833
 LSA : Secured foreign UG Bad drive is not showing Crypto erase option at first, after doing Crypto erase from Storcli & then LSA shows CE option for that UG Bad drive(DCSG01103089
 PSOC6 LSA 7.20: PSOC current and selected version spelling is displayed as "vesrion" during PSOC update(DCSG01137889
 Fixed: allow multiple DG creation(DCSG01074166
 LSA_MR7.20_PA:Multiple PDs and VDs selection is not working.(DCSG01039219
 WebGUIRelease_7.20_PA-007.020.004.000-DCSG01042991: "LSA will generate alerts from events since last clean shutdown" & "Starting Gateway installation of LSIStorageAuthority" has "\n" character.(DCSG01043665
 Drive count is showing "0" always under "other hardware" tab in LSA when user connects Tape drive, however storcli shows it properly(DCSG01093643
 Virtual Drive Capacity GUI issue when Disk Cache Policy selected(DCSG00973715
 LSA:AeroMR_7.20:BGI progress information is displayed on issuing PAUSE command(DCSG01052255
 LSA Reference in MRSA readme for Linux(DCSG01080850
 22B Alpha Tape Drive LSA: Mismatch in sector size displayed in server profile and unconfigured good page.(DCSG01112937
 LSA: WebGUIRelease_7.20_PA-007.020.004.000-DCSG01042991: Email settings should have a check for @.(DCSG01048568
 WG: updating PSOC firmware shows Online firmware update is in progress(DCSG01140787
 22B-PSOC6- LSA shows inappropiate message for wrong PSOC image flash(DCSG01132438
 Fixed: allow >32 drive R10(DCSG01039688
 Update the nginx with the SSL flags(DCSG01071924
 WG_RWC3: RWC3 fails to launch from desktop shortcut(DCSG01027396
 Refresh issue of "Port number" under Manage SAS Storage Link Speed though Tape drive has been removed from the setup.(DCSG01096142
 LSA: PD Crypto Erase failed due to error "Description: This is an OS Drive. Erase cannot be performed"(DCSG01061602
 fixed: Max drives for R00(DCSG01040107
 LSA Server: Microsoft Windows API usage (Release function)(DCSG01015555
 fixed: LSA : Controller critical/need attention message is showing wrongly as it has multiple duplicate entries(DCSG01111618
 LSA_MR_7.20_PA2: "Make JBOD" option is displayed for Foreign drive(DCSG01030118
 LSA : JBOD conversion option is coming for Tape drive if the drive is in UG mode, if user clicks JBOD & it shows failure message with error code 38(DCSG01113102
 LSA-MR7.20:Unable to close message dialog on selecting configured PDs > 32 PDs to 240 PDs under Drive Group Tab> PD Tab(DCSG01044347
 Fixed: timout seen during import(DCSG01033216
 LSA : Controller Drop down menu lists the controller above the drop down menu, due to this controller is not seen sometimes though user clicked the ctrlr drop down menu(DCSG01107334
 LSA : Type is not showing any info in Drives information under server profile for Tape drive, whereas the main page of controller shows the type properly(DCSG01111968
 install SLP from installation source beforr. "before" to be corrected.(DCSG01039227
 LSA : RHEL 8.5 OS is not present in the Linux readme file(DCSG01137293
 LSA : EPAK failed event shown SOH Bad(DCSG01145362
 22B Alpha LSA CFF 440-16i: After PD removal/ insertion other hardware count is displayed as 0 in LSA.(DCSG01130124
 Click on other hardware tab remove/insert drive to controller, observe that other hardware information is not displayed.(DCSG01142250
 Select all is selecting all the drives when the number of drives is more than the selectable drives(DCSG00982356
 22B-PSOC6 -OFU windows shows Imporper message during PSOC flash via LSA(DCSG01128864
 WG: LSA Crashes on trying to flash PSOC from LSA(DCSG01126644
 WebGUIRelease_7.20_PA-007.020.005.000-DCSG01058115: New line is not handled properly in the installation scripts.(DCSG01058946
 LSACommon: Restore users files while upgrading LSA(DCSG01073725
 Fixed: LSA : Health of enclosure is showing as "Unknown" always for good/bad enclosures(DCSG01111545
 7.20 Readme is not having Win 2022 OS in supported OS list, however 7.19 LSA readme has Win 2022 OS(DCSG01105553
 OEM details for Embedded controllers in windows OS(DCSG01075803
 Email settings should not have a check for @.(DCSG01090903
 fixed: Enclosure status is displayed as blank in server profile.(DCSG01111966
 For IT controller tty log file is part of Download Server Report(DCSG00966716
 LSA:AeroMR_7.20PA: Previous configuration BGI is displayed post clear config(DCSG01039961
 LSA-7.20_PA - 007.020.002.000 shows jbod for unsupported MA drives(DCSG01035032
 LSA : If user clicks "connected device" under Manage SAS Storage Link Speed, it is not showing any details when user has Tape drive(DCSG01096124
 discovery issue: When the remote server is down the server is not removed from discovered list(DCSG01030008
 Boca 540-16i: LSA displays enclosure/BP logical ID in reverse order.(DCSG01025576 (Port Of Defect DCSG01028918)
 LSA: Faulty Enclosure state is displayed as optimal in LSA(DCSG01080760 (Port Of Defect DCSG01088781)
 Lib_utils rpm not proper and does not have SSL files bundled for LSA aarch64(DCSG01015405 (Port Of Defect DCSG01016303)
 LSA : Statement needs to be modified under Enable security as it shows "Virtual drives" for IT controller(DCSG01136168 (Port Of Defect DCSG01140911)
 DCSG01109800 (Port Of Defect DCSG01119229)
 LSA: Faulty Enclosure state is displayed as optimal in LSA(DCSG01080760 (Port Of Defect DCSG01088782)
 Rebuild operation not seen on an offline drive with Raid 6 , 5 drives created(DCSG01099765 (Port Of Defect DCSG01102969)
 4K Physical Drive JSON file raw size do not match with value shown in JSON(DCSG01016816 (Port Of Defect DCSG01017165)
 WG: JSON File in the servers and serverdetail log folder shows different port numbers(DCSG01075773 (Port Of Defect DCSG01091661)
 LSA Client: IT Connector status value for the PD is not displayed(DCSG01099751 (Port Of Defect DCSG01105329)
 LSA Server: IT Connector status value for the PD has an issue(DCSG01099750 (Port Of Defect DCSG01099752)
 LSA : Manage SAS storage link speed is not showing one of the connected device behind BP(DCSG01026787 (Port Of Defect DCSG01028684)
 LSA: PD Crypto Erase failed due to error "Description: This is an OS Drive. Erase cannot be performed"(DCSG01061602 (Port Of Defect DCSG01062281)
 Enclosure location is displayed as "unknown" instead of internal/external under enclosure properties in physical device properties(DCSG01080769 (Port Of Defect DCSG01089861)
(DCSG01052255 (Port Of Defect DCSG01052266)
 Shenandoah_Snap5:LSA - Drive Firmware version not reported proper in LSA for an NVME drive(DCSG01123114 (Port Of Defect DCSG01130058)
 LSA Avenger_8.1 : Mutliple snapdump file download is showing action successful message, but files are not downloaded.(DCSG01060164 (Port Of Defect DCSG01068639)
 LSA MR 7.19: LSA crashed on clicking Drives TAB post 240 R0 VD deletion(DCSG01013919 (Port Of Defect DCSG01031302)
 Modify the License (or) copyright year to 2022(DCSG01109800 (Port Of Defect DCSG01109801)
 Enclosure location is displayed as "unknown" instead of internal/external under enclosure properties in physical device properties(DCSG01080769 (Port Of Defect DCSG01086649)
 MR7.19 PA2:LSA-02: "Make JBOD" option is not displayed for Aero MR(MegaRAID 9580-8i8e) & Aero iMR(9540-16i)(DCSG01002945 (Port Of Defect DCSG01018282)
 LSA MR 7.19: LSA crashed on clicking Drives TAB post 240 R0 VD deletion(DCSG01013919 (Port Of Defect DCSG01030620)
 LSACommon: Restore users files while upgrading LSA(DCSG01073725 (Port Of Defect DCSG01091973)
 Boca-540-16i : LSA -BP logical id shown as junk(DCSG01014125 (Port Of Defect DCSG01019750)
 Avenger_WG: As part of negative test, manual discovery of vmware server and login crashes LSA(DCSG01015031 (Port Of Defect DCSG01018410)
 Fixed: Update curl library with secure flags(DCSG00963302 (Port Of Defect DCSG01024511)
	
EnhancementRequests:	
 Update ControllerInfo Structure with PartNumber - API Changes(DCSG01064529
 Enable end user tools to read custom SN - part 2(DCSG00950274
 Enable end user tools to read custom SN - part 2(DCSG00950275
 API change to support PD sanitize operations enhancements(DCSG01070995
 Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API(DCSG01065378
 Windows Client Win11 OS Support - MR6.14, SAS3 Phase 16, MR 7.20, SAS3.5 Phase 22 (OS GCA Date - 10/05/2021)(DCSG01043610
 LSA GUI Support for Aero 9560/9580 - Add PSOC6 as Vision Controller(DCSG01077815
 Image change - branding for Intel RAID Web Console 3 (LSA rebranded)(DCSG01008558
 Aero 9560/9580 - Add PSOC6 as Vision Controller(DCSG01075692
 Make offline bundle for LWA and LWM ESXi(DCSG01150074 (Port Of EnhancementRequest DCSG01150081)
 Implimented: TCP/HTTP Fortification(DCSG00436245 (Port Of EnhancementRequest DCSG01147883)
 Windows Client Win11 OS Support - MR6.14, SAS3 Phase 16, MR 7.20, SAS3.5 Phase 22 (OS GCA Date - 10/05/2021)(DCSG01043610 (Port Of EnhancementRequest DCSG01068997)

007.019.006.000 - Moderate Impact
---------------
MR 7.19
-LSA : Able to update different Aero-IT HBA FW file (16i) to different model IT-Aero card (16e).(DCSG00986871)
-LSA MR 7.17: Sorting is not working in the span tab of VD in presence of missing drive..(DCSG00946017 (Port Of Defect DCSG00757915))
-AERO _MR_LSA_7_18:Under Personality management > change behavior mode, "Change " button is disabled even though.(DCSG00960275 (Port Of Defect DCSG00907541)
-Update VMware DCPN cases for ESXi 6.7U3 and ESXi 7.0U2.(DCSG00985708 (Port Of Defect DCSG00950625))
-WG: test email fails with NON-auth login when 'sender email address' is set to anything other than domain "@server.com" for.(DCSG00986188 (Port Of Defect DCSG00940109)
-Drive import is success however the message shows incomplete when importing unlocked drive.(DCSG00988921 (Port Of Defect DCSG00734940))
-LSA reports wrong version for the OS..(DCSG00990503 (Port Of Defect DCSG00990486)
			
007.017.015.000 - Moderate Impact
---------------

Defects:
-WG: Enclosure connector info in PD properties shown "C0 & C0" instead of "C0 & C1".(DCSG00775146
-WG: Logging in to manage server page and clicking on VMware server for login results in VMware login page refresh indefinitely.(DCSG00397834
-WG: Snapdump not getting downloaded with ARM MR 7.17 LSA.(DCSG00653578
-Invalid Enclosure logical ID is displayed is LSA for enclosure connected to Hialeah 8e controller..(DCSG00967815
-LSA MR 7.17: Modifying VD size is not getting updated , if the VD size is more than the current VD size..(DCSG00718530
-WG: LSA service does not start automatically on reboot on OpenEuler.(DCSG00648374
-HBA not listed with index order under Server Profile.(DCSG00418634
-Remote Server Health status without controller is not proper.(DCSG00528112
-WG: RWC3 Linux supports obsolete SHA1-based ciphersuites.(DCSG00500737
-Ventura_LSA_7.17: Under change behavior mode, "Change " button is enabled even though configuration parameter in unchecked.(DCSG00706331
-LSA : OLH shows lane speed values as Unknown, 2.5GT/s, 5GT/s, 8GT/s for Manage PCIe Storage Interface instead of showing 2.5GT/s, 5GT/s, 8GT/s & 16GT/s.(DCSG00971355
-LSA does not launch on ARM Open Euler : 007.017.008.000 ARM build.(DCSG00905358
-LSA service is stopped, after LWM (option4) installation in Ubuntu 20.04 arm system..(DCSG00506960
-Fixed: Added interface check for appropriate mix policy.(DCSG00706336
-behavior mode values is not being set properly.(DCSG00426348
-change button is not enabled for Behavior params change.(DCSG00426709
-WG: DLL files packaged in monitor folder of ARM LSA installation.(DCSG00706354
-Linux, RHEL 8.3 - Blank screen shown on launching latest LSA.(DCSG00777144
-LSA MR 7.17: Make JBOD option is available for all the UGOOD PDs, even though one of the PD is in drive clear process..(DCSG00775455
-Login page help link is showing blank.(DCSG00548034
-Fixed: updated Build script to change permissions of different file types.(DCSG00776044
-LSA is not allowing user to create more than 2 VDs.(DCSG00726030
-Handle the new event LD_ERASE_POTENTIAL_LEAKAGE in client.(DCSG00776413
-Fixed: enclosure state is to be shown need attention when it is in fault state.(DCSG00965622
-Ventura_LSA_7.17: LSA still displays background processes of VDs(VD init) post clear config from LSA.(DCSG00644476
-Ventura_LSA_7.17: LSA crashes on creating 64th VD.(DCSG00708134
-Warning removal as part of new gcc upgrade..(DCSG00757533
-Fixed: Changing Resource type displays recover option.(DCSG00411317
-Ventura_LSA_7.17: Event ID: 633 is generated on changing VD policy when expansion is in progress.(DCSG00650740
-LSA MR 7.17: LSA has older version of LSA_Lib_Utils packaged..(DCSG00397682
-WG: Power supply details are not shown on clicking "No of Power Supplies" in enclosure properties.(DCSG00544568
-LSA MR 7.17 : When partially degraded VD erase is in progress, Erase option is available in Elements Action instead of Stop Erase.(DCSG00758642
-Fixed: Added security flags to make file to build secure LSA binaries.(DCSG00813569
-Legacy:LSA MR 7.17: Upon clicking on the hostname(administrator/root )drop down for the second time, Remote Server discovery option appears twice..(DCSG00396896
-Fixed: Added security flags to LSA Makefile.(DCSG00814604
-WG: VMware user able to download LSA logs of gateway.(DCSG00384359
-Fixed: added directory wise permission while creating corpus.(DCSG00543670
-WG: Server ID cookie generated after login has "httponly", "secure" and "sameSite" fields empty for RWC3 installation.(DCSG00547995
-LSA Client WG: Power supply details are not shown on clicking "No of Power Supplies" in enclosure properties.(DCSG00549353
-LSAServer - WG: Redhat OS icon shown for OpenEuler OS in remote discovery page and Manual discovery page.(DCSG00735182
-WG: Redhat OS icon shown for OpenEuler OS in remote discovery page and Manual discovery page.(DCSG00652676
-Ventura_LSAMR_7.17:VD initialization progress is displayed on triggering VD expansion..(DCSG00776513
-WG 7.17 PA2: error token 009" seen when LSA downgrade is performed from 7.17 PA2 to 7.16 RC build and complete LSA uninstallation is not successful.(DCSG00434242
-Ventura_LSAMR_7.17: Background process displays previous status information post clear config.(DCSG00830097
-WG: LSA allows providing same Busy port to both Webserver and LSA port, ultimately LSA service fails to start.(DCSG00556924
-LSA MR 7.17: In RLM page After applying/clearing filter, Add Physical drive tab is enabled even though no drives are selected..(DCSG00649177
-LSA shows stale data and failed to refresh topology until LSA service restart.(DCSG00477447 (Port Of Defect DCSG00708193)
-Fixed: state-change isn't updating state of the PD incase of bad to good.(DCSG00834219 (Port Of Defect DCSG00916906)
-LSA : While updating UEFI for 440-16e (Aero-IT), "Image update failed" message is coming and next time it passes.(DCSG00935787 (Port Of Defect DCSG00937166)
-LSA Common: Stale folders still persist in html folder.(DCSG00388225 (Port Of Defect DCSG00394666)
-Fixed: Limit R1 from R6 migration, show when applicable.(DCSG00776529 (Port Of Defect DCSG00960423)
-Fixed: modify virtual drive to show appropriate allowed operation values.(DCSG00433726 (Port Of Defect DCSG00518957)
-WG: Server ID cookie generated after login has "httponly", "secure" and "sameSite" fields empty for RWC3 installation.(DCSG00547995 (Port Of Defect DCSG00654119)
-LSA : PDs are not listing properly after pull/push from enclosure/Backplane.(DCSG00916164 (Port Of Defect DCSG00917749)
-change button is not enabled for Behavior params change.(DCSG00426709 (Port Of Defect DCSG00428813)
-LSA : PDs are not listing properly after pull/push from enclosure/Backplane.(DCSG00916164 (Port Of Defect DCSG00917716)
-Fixed: StateChange Event handled to update repository.(DCSG00555478 (Port Of Defect DCSG00708165)
-Fixed: Corrupt image file leads to LSA crash.(DCSG00951718 (Port Of Defect DCSG00960390)
-LSA displays all lane speed values under Manage PCIe storage interface.(DCSG00547375 (Port Of Defect DCSG00549936)
-Fixed: Parameter 16GT is not visible while updating lane speed.(DCSG00255550 (Port Of Defect DCSG00960305)
-LSA MR 7.18: LSA events shows full description of the behavior mode(Jbod) change instead of mentioning Mode name..(DCSG00913588 (Port Of Defect DCSG00960083)
-LSA allows to upgrade without uninstalling previous version of LSA in Ubuntu 18.04.05.(DCSG00435199 (Port Of Defect DCSG00500750)
Headline:.(DCSG00965622 (Port Of Defect DCSG00980121)
-LSA : RHEL 7.9 , Ubuntu 18.04.5 and ESXi7.0u1 OS are missing in Linux LSA readme file & ESXi7.0u1 OS is missing in Windows LSA Readme file.(DCSG00421344 (Port Of Defect DCSG00506913)
-PH19 Alpha - LSA - HBA listed with incorrect index order under view server profile.(DCSG00930402 (Port Of Defect DCSG00960246)
-LSA Windows installation from CDROM fails - error opening installation log file.(DCSG00944480 (Port Of Defect DCSG00944695)
-Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00501331)
-Shenandoah_MRSA:Enclosure Location and Status coming as Unknown in MRSA when Click to download all the Enclosure or Backplane properties.(DCSG00412122 (Port Of Defect DCSG00414363)
-VenturaLSA_7_18: Unable to trigger Fast initialization on VDs.(DCSG00959286 (Port Of Defect DCSG00960876)
-Set PR properties are showing offline VDs and user is able to add those offline VDs for Patrol read operation.(DCSG00906763 (Port Of Defect DCSG00919131)
-Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys.(DCSG00423048 (Port Of Defect DCSG00495341)
-LSA : "Unlock" button is not getting enabled if user copy & paste the LKMS passphrase in the security key text box.(DCSG00923594 (Port Of Defect DCSG00925032)
-21B- LSA allows EKM to LKM migartion & ask for Authentication key.(DCSG00920215 (Port Of Defect DCSG00925030)
-Shenandoah_MRSA : OLH link for MRSA OEM build refers to screenshots of non-OEM build.(DCSG00501038 (Port Of Defect DCSG00519848)
-Aero MR : LSA Channel: Drive connector information not displayed correctly when compared with Storcli output.(DCSG00416118 (Port Of Defect DCSG00416248)
-LSA: PD insertion event display issue.(DCSG00840938 (Port Of Defect DCSG00916909)
-Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys.(DCSG00420399 (Port Of Defect DCSG00421316)
-LSA services not starting after installing LSA on RHEL 8.3.(DCSG00915932 (Port Of Defect DCSG00916838)
-LSA Server: Code refresh based on Security Tool findings.(DCSG00500569 (Port Of Defect DCSG00501486)
-LSA : Manage SAS Storage Link Speed is setting values only for 2 phys out of 4 phys if user sets it from LSA.(DCSG00916870 (Port Of Defect DCSG00944446)
-Fixed: state-change isn't updating state of the PD incase of bad to good.(DCSG00834219 (Port Of Defect DCSG00916893)
-LSA : Enable/Disable SSD caching is not working for all VDs at once if user selected multiple VDs and enabling/disabling SSD cache.(DCSG00409275 (Port Of Defect DCSG00415053)
-LSA MR 7.18: Click to download option is enabled in Download snapdump page, eventhough no files are selected for download..(DCSG00922702 (Port Of Defect DCSG00960272)
-Fixed: Added security flags to LSA Makefile.(DCSG00814604 (Port Of Defect DCSG00816013)
-LSA cursor is actively cycling after failed to import the max (240Lds) LDs reached.(DCSG00921402 (Port Of Defect DCSG00922051)
-Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00501332)
-Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00554176)
-LSA : Loopback IP address is not coming after restarting LSA service if there is no LAN/NIC card.(DCSG00417564 (Port Of Defect DCSG00421192)
-WG: login to manage server page with readonly access and then login to any VMware system, logout to VMware grants readonly user "Admin" previlige.(DCSG00384343 (Port Of Defect DCSG00401650)

EnhancementRequest:
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00388186
-LSA: Add Event for possibility of incomplete writes on parity VDs with no battery backup (ER: DCSG00229751).(DCSG00735186
-Implimented: TCP/HTTP Fortification.(DCSG00436245
-Enable end user tools to read custom SN.(DCSG00938513
-Aero-Margay Connectivity Solution Integration - MR API.(DCSG00956233
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00394652
-Implimented: Additional error code handled.(DCSG00310385
-update dependent to comply with latest OS support.(DCSG00428823
-Upgradation of dependent component with security flags.(DCSG00427912
-Request IT read Product Name/Model Number for SATA drives so that the Product Name/Model Number is displayed in full + FW Version.(DCSG00371060
-Added support for RHEL 8.3.(DCSG00373404
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00388184
-Upgrade of OpenSLL and its dependent components.(DCSG00404741
-LSA: Short term solution for handling SES cable missing to Atlas.(DCSG00735187
-Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596
-Add OpenEuler OS (20.03 LTS) support on Kunpeng 920 Gen4 ARM for Ventura MR/iMR (Driver Binary, StorCLI, Storelib, LSA).(DCSG00546575
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00388185
-MegaAPI: Add API changes for temporary key escrow (PR: DCSG00428069).(DCSG00935525
-Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00937396)
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00388184 (Port Of EnhancementRequest DCSG00394003)
Headline:.(DCSG00427912 (Port Of EnhancementRequest DCSG00432022)
Headline:.(DCSG00427912 (Port Of EnhancementRequest DCSG00431998)
-Linux: LSA service script improvement.(DCSG00841007 (Port Of EnhancementRequest DCSG00903463)
Headline:.(DCSG00404741 (Port Of EnhancementRequest DCSG00427334)
-Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596 (Port Of EnhancementRequest DCSG00553614)
-Apps Advanced Security Enhancements and updates - part 2.(DCSG00394652 (Port Of EnhancementRequest DCSG00447326)
-Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596 (Port Of EnhancementRequest DCSG00654068)
-LSA: Linux 32 bit binary removal.(DCSG00221416 (Port Of EnhancementRequest DCSG00408188)
-Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00941433)
-Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00937397)
-Added support for RHEL 8.3.(DCSG00373404 (Port Of EnhancementRequest DCSG00428725)


007.016.021.000 - Moderate Impact
---------------

Defects:
-LSA : While updating UEFI for 440-16e (Aero-IT), "Image update failed" message is coming and next time it passes.(DCSG00935787)

Enhancements:
-Update comment for SL_ERR_IR_INVALID_FW_FLASH_IMAGE_NVDATA.(DCSG00936705)

007.016.015.000 - Moderate Impact
---------------
MR 7.16

Defects:
 -Instance validation fails for Manage Server GET (MR 7.14, 7.014.000.000): Schema 32(DCSG00079899)
 -LSA 7.15 WG: "Replace Missing drive" page will not open after clicking and closing "Assign Dedicated hotspare" page.(DCSG00167347)
 -LSA MR 7.16: While Updating the firmware Selected Firmware Version is showing wrong text instead of Firmware Version.(DCSG00359474)
 -LSA WG : Uninstall instructions mentioned in LSA ESXi readme is wrong.(DCSG00126899)
 -LSA 7.14 : Clicking on "Configure" option from server landing page is redirecting to controller info page instead of Advanced config page.(DCSG00125950)
 -Physical drive Serial number info should be populate in LSA(DCSG00321940)
 -Legacy:WG 7.14 PA2: Unconfigured Bad drive count is not updated for Drive tab when Vds are created.(DCSG00092875)
 -WG: Folder structure remains after uninstalling the direct agent on windows(DCSG00347401)
 -WG: RWC3 Ubuntu Linux build (07.016.003.000)loads with http instead of https(DCSG00384392)
 -Fixed: Clear staging directory to allow new downloads(DCSG00127783)
 -Description of the behavior of the "fast initialization" on RWC3 is inaccurate (Intel re-branded LSI Storage Authority/LSA)(DCSG00263417)
 -Current speed under "Manage PCIe storage interface" is showing like 2.5GT, 5GT, 8GT instead of 2.5GT/s, 5GT/s, 8GT/s(DCSG00301958)
 -WG 7.14: Invalid VD capacity displayed while creating AddVD on a hole with invalid number of VDs(DCSG00080851)
 -Select all checkbox needs to be consistent in all the tabs(DCSG00108298)
 -LSA-Missing rebuild when a drive goes offline by physical removal(DCSG00327294)
 -Fixed: check spdm support bit before populating details(DCSG00108070)
 -Aero : MR 7.16 -Channel: Mismatch between LSA and Storcli output for drive firmware version(DCSG00342645)
 -Update the PD size for higher size 4k Drives(DCSG00395158)
 -Fixed: Security node is being populated for non secure drives(DCSG00140174)
 -LSA MR 7.16: Sorting is not available in "JBOD to Unconfigured Good conversion" page.(DCSG00311369)
 -Enable Drive Security has incorrect phrase and incorrect word. Forcing a Offline PD, confirmation message shows incorrect word.(DCSG00358750)
 -MR 7.16 : Aero Channel : LSA: "Virtual Drives" should be printed for message event id= 195 instead of logical drives(DCSG00316205)
 -LSA WG: Wrong tool tip is seen on Apply button, while filtering the drives.(DCSG00074726)
 -reference to Virtual Drive instead of Logical Drive in ReadMe(DCSG00111540)
 -Fixed: secure discovery handling(DCSG00318199)
 -LSA WG: Help(?) icon present in LWA in "Schedule Consistency check" page.(DCSG00129159)
 -LSA WG 7.15 : Add hotspare option is enabled for spanned raid levels, even after creating VD.(DCSG00226412)
 -Fixed: Import certificate with Seal is not working, Seal is not enabled after import.(DCSG00122476)
 -fixed: update switch to be displayed as managed switch(DCSG00140169)
 -LSA WG: LSA is allowing to add virtual drives more than 16, when spandepth is increased/decreased.(DCSG00084397)
 -Voltage sensor values are shown in negative for atlas board(DCSG00151544)
 -LSA Client: Behavior mode parameters is not shown(DCSG00079966)
 -LSA: While creating 64 slice VD on same DG the 10th VD Name creating as VDName_010 instead of VDName_10(DCSG00253718)
 -WG 7.14 : in AERO IT controller, the enclosure serial number is shown blank, Storcli shows NA(DCSG00138884)
 -Legacy: LSA WG: LSA is allowing to change the personality mode of the controller in Non-admin access.(DCSG00083219)
 -WG: no status code is displayed on failure of "start recover" operation(DCSG00105107)
 -LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings(DCSG00134600)
 -WG 7.14: In Physical Drive properties, Multipath field is showing "Yes" for all the drives attached, eventhough drives are not in Mulitpath configuration.(DCSG00092819)
 -7.14 LSA : Update the LSA readme.(DCSG00108916)
 -WG: LSA Does not have filter button in drives tab for IT controller Controller console page(DCSG00138885)
 -LSA MR 7.16: Sorting is not working after clicking on Filter option in RLM page.(DCSG00359695)
 -LSA MR 7.16: Modify Virtual Drive field is disabled after changing the unit value from GB to MB.(DCSG00345377)
 -WG: Instance Validation failed for event History get,( MR 7.14, 7.014.004.000): MR Ventura: JBOD mode(DCSG00129472)
 -LSA 7.15 WG: "Make JBOD" option is available for the drives which are Prepared for removal.(DCSG00212830)
 -VD Read cache policy displayed wrong as RA , whereas detailed VD policy shows correct(DCSG00148244)
 -MR 7.16 :Channel_ LSA: VD property modification ( WT to AWB) event description not in sync with the actual VD property(DCSG00323028)
 -fixed: Recovery of NVME drives(DCSG00104462)
 -WG: Creation of simple configuration with dedicated hotspare, LSA creation notification does not include hotspare in total PDs used in config creation(DCSG00259092)
 -LSA MR 7.15: Add Virtual Drive field is enabled and VD is added for patrol read, even after unselecting all VDs in Set Patrol read page.(DCSG00228853)
 -In server settings page under email tab, in absence of any email id, Test configurartion should be disabled(DCSG00146660)
 -WG: Selected element minor GUI issue in naming convention, LSA continues to show download in progress continuously(DCSG00151401)
 -MR 7.16 : LSA: Logical ID of enclosure is not displayed correctly(DCSG00316050)
 -LSA 7.14: Set adjustable task rate field is not allowing to save the changes.(DCSG00126266)
 -LSA Client : Handle Manual Discovery failure cases(DCSG00098052)
 -Manage PCIE Storage interface does not show any data.(DCSG00340896)
 -Enclosure Location and Status coming as Unknown when Click to download all the Enclosure or Backplane properties(DCSG00412122)
 -Silent installation with default Web server port and default LSA port is failing.(DCSG00092962)
 -LSA MR 7.16: Number of VDs is not getting updated after deleting the first created VD.(DCSG00361755)
 -When selected 6272 KB firmware for update failure seen with message as file is more than 16MB size(DCSG00080838)
 -LSA Conf: Clean and remove unused fields(DCSG00297566)
 - -WG 7.14 : VD expansion more than 100 % is allowed in LSA(DCSG00126745)
 -"The given port is in use the next available port " message seen During every DA installation(DCSG00412121)
 -LSA MR : Replace Missing drive option is available for Non-admin privileges.(DCSG00298090)
 -WG: login to manage server page with readonly access and then login to any VMware system, logout to VMware grants readonly user "Admin" previlige(DCSG00384343)
 -LSA MR 7.16 :Progress bar is not shown for Rebuild and Patrol read operations for Non-admin privileges.(DCSG00347097)
 -WG: Instance Validation failed for Controllers get,( MR 7.14, 7.014.004.000)(DCSG00129470)
 -for IT Controller update firmware radio buttons and text does not have clickable hand icon(DCSG00138887)
 -Fixed: Added remove files after files are zipped for snap dump download(DCSG00085869)
 -Enclosure location coming as "unknown" for UBM3 if you boot the system without any drives connected(DCSG00081762)
 -LSA: Filter options does not list NVMe drives in PD list of controller console page(DCSG00138709)
 -LSA: Modifying VD properties during Multiple VD creation list the VD name as "VDName_00" instead of VDName & Modify VD page does not have hand symbol for help icon(DCSG00354486)
 -LSA7.16_Linux compiler specific changes(DCSG00340258)
 -Non-interactive/silent installation does not have options to install LSA based on EVENT NOTIFICATION CHOCIES.(DCSG00078199)
 -WG MR 7.14 PA: Clear option grayed for an incomplete foreign configuration(DCSG00085818)
 -Version not reflected correctly when we upgrade MRSA in ubuntu(DCSG00404727)
 -In Set patrol read properties page, Unselected VD is also added for Patrol read.(DCSG00259156)
 -LSA read me: Update the Open Source details(DCSG00353259)
 -updation of libfcgi.dll with DYNAMICBASE flag(DCSG00426989)
 -Change button is enabled when no change performed in Change Behavior Mode(DCSG00382779)
 -MR 7.14 PA2: Rescan Under foreign config menu is grayed out after importing foreign Vd.(DCSG00101341)
 -LSA does not display full message, while making an offline drive online of a VD from Server Landing Page.(DCSG00366127)
 -Fixed: lib utils version update(DCSG00360539)
 -LSA uninstallation is failing on HPE(DCSG00164985)
 -VDs of different capacities(MB/GB) is not sorting properly.(DCSG00080102)
 -Cisco M6: Selecting drive after filter is applied Element selection is shown as "Zero".(DCSG00278212)
 -API clarification for large io support(DCSG00307042)
 -WG 7.14 PA2: 'show password' and 'show key' are active for "Pause for password at boot time" under 'change drive security'.(DCSG00108259)
 -WG: making an offline drive online of a VD from server summary page, LSA does not notify regarding the destructive operation.(DCSG00340323)
 -RWC3 windows build (07.014.004.000)loads with http instead of https(DCSG00125606)
 -Shenandoah_MRSA:Error message not proper for Ubad to UGood for a Bad drive(DCSG00092851)
 -LSA WG: Alignment issue in Manage server page.(DCSG00138055)
 -RWC3 windows Header has LSA Storage Authority as product name instead of RAID Web Console 3.(DCSG00125329)
 -Fixed: Added code to change content type which is acceptable to IE(DCSG00138898)
 -LSA MR 7.15 Alpha: Clicking on "modify" icon will enable the Add Virtual Drive field even after creating a VD of full size(DCSG00293914)
 -fixed: changed unit to Byte in case of zero size drives(DCSG00072680)
 -LSA Windows: Usage of nginx 1.18 version which is a stable version(DCSG00324413)
 -Fixed:SPDM configuration page shows as blank In LSA(DCSG00138574)
 -Legacy : LSA WG 7.14: Remove Manage server icon is not placed properly for Manually added ESXi servers in List view.(DCSG00110210)
 -MR 7.16 :Channel_ LSA: Missing warning message when tried to modify PCIe Storage Interface(DCSG00358742)
 -Use NVRAM to save PTB information -- API changes(DCSG00082981)
 -When heavy IOs active, LSA is taking very long time to download server report .(DCSG00092899)
 -MRSA Desktop icon should not be present for Ubuntu as per the Read me(DCSG00099517)
 -WG 7.14 PA2: LSA installation on Ubuntu, fails with error "LSA_lib_utils" : Gateway can not be launched(DCSG00089795)
 -Manage server page throws error message "400:" for invalid credentials.(DCSG00136334)
 -WG 7.14 PA2: Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 7.8(DCSG00092841)
 -WG: LSA fails to create Drive group for Non-span depth supported Raid volumes.(DCSG00089810)
 -x Readme needs some modification on supported OS and reference as MRSA in some places(DCSG00146624)
 -WG: Sorting is not working as expected in drives tab with multiple spans. with a span having a missing drive(DCSG00341095)
 -LSA Windows x64: Some of the OS is having an issue(DCSG00307418)
 -LSA MR 7.16: Sorting based on Drivegroup is not proper in Assign dedicated hotspare page.(DCSG00322767)
 -Launchpad on desktop of Rhel 7.7 is shown as "LaunchLSA" instead of "LaunchMRSA"(DCSG00072655)
 -LSA shows FW update failure message even after FW update is successfull.(DCSG00082492)
 -LSA 7.15 WG: Sorting based on Drive group capacity is not proper in "Assign Dedicated hot spare" page.(DCSG00166089)
 -Update credits files in client credits(DCSG00353889)
 -Shenandoah_MRSA:Event description blank for 628,629 in MRSA(DCSG00325879)
 -Fixed: Monitor Conf files are missing write permission(DCSG00129770)
 -Fixed: Spanned drive min vd check calculation error(DCSG00138063)
 -Update Credits.html with updated licenses(DCSG00428654)
 -LSA MR 7.15 : LSA does not show message while modifying Disk cache policy of VD in Advanced configuration page.(DCSG00263699)
 -Upgrade is not working in ubuntu from 7.15 to 7.16 packages(DCSG00315134)
 -LSA : Loopback IP address is not coming after restarting LSA service if there is no LAN/NIC card(DCSG00417564)
 -MR controller with No Alram is not auto refreshing on changing the controller properties(DCSG00124484)
 -On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04(DCSG00105871)
 -displays 0 Needs attention when we have degraded LDs(DCSG00092831)
 -WG 7.14 : Mismatch seen in the total number of available UG drives and actual no of PDs in PD list during encrypted R60 VD creation.(DCSG00134663)
 -LSA - Set PR properties is showing VD as optimal though it is offline or degraded(DCSG00226300)
 -Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2(DCSG00115253)
 -Fixed: updated Readme with "Health status shown in LSA is as per LSA's health algorithm."(DCSG00412125)
 -LSA MR 7.16: Changing the lane speed in Manage PCIe storage interface page is showing Operation is either not allowed or not supported, whereas storcli shows Success reboot required(DCSG00397804)
 -WG: ""Your connection is not Private" shown twice in "Manage server page"(DCSG00391486)
 -Legacy : WG: LSA auto logs in on clicking "verify" button for "Managed" VMware manually added server in managed server page(DCSG00112178)
 -Fixed: updated nginx and libcurl(DCSG00414394)
 -WG: Sorting does not work in Span tab of VD in presence of missing drive(DCSG00258267)
 -Fixed: Build script changes to pick up the latest conf and ini files(DCSG00125997)
 -SSD WearGuage Estimated Life Remaining in Percent as "N/A" for New Drives(DCSG00074664
 -Fixed: Certificate Algorithm details are showing blank for few certificate slots.(DCSG00123069)
 -LSA fails to import R0 which has pinned cache after a reboot(DCSG00356398)
 -WG: instance validation failed for controllers Operations GET: iMR Ventura : Schema 34: MR 7.16(DCSG00342339)
 -LSA service fails to start when LSA port value is set to 2463(DCSG00083383)
 -Secured foreign locked VDs details are not displayed under foreign configuration to import/clear foreign config(DCSG00103239)
 -LSA Server: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00114253)
 -Fixed: Invalidate certificate slot is failing with error code 165.(DCSG00122448)
 -LSA WG: Non-span depth supported raid levels are showing "Span depth modify" option in Advanced config page upon clicking on "Compare and select" link.(DCSG00143503)
 -LSA MR 7.15 Alpha: Changing the number of spans while creating DG shows wrong info about the Number of VDs can be added to DG.(DCSG00264033)
 -LWA Compilation Issue Resolution(DCSG00228825)
 -Only the text in "Start recover" operation for bad NVMe drive is clickable(both CC and ss Page), GUI issue on expanding the controller health(DCSG00105108)
 -LSA WG: In Advanced configuration page, hotspare PD adding page disappears when users scrolls up/down the LSA page.(DCSG00080074)
 -MR7.15 LSA Client: Unsupported icon in Server and Controller Dashboard(DCSG00277830)
 -WG: No success or failure icon is shown on silencing alarm, hand symbol is not present for close icons in advanced enclosure properties(DCSG00255201)
 -WG: nginx conf file after installing DA is empty. unable to manage the DA from Gateway though DA LSA service running(DCSG00383999)
 -Clear configuration is success when JBOD has OS(DCSG00382535)
 -LSA Server: Hard coded string over disk and controller implementation(DCSG00152933)
 -Enclosure Name not correct for x4 Backplanes Connected via Straight cables to two controllers.(DCSG00315377)
 -WG: Instance Validation failed for servers get,( MR 7.14, 7.014.004.000)(DCSG00129468)
 -PH15 LSA IT:In RHEL7.8 for enclosure drives Multi path field is showing as"Yes" In Physical Drive properties,without Multipath configuration(DCSG00132726)
 -Shenandoah: MRSA: VD reference in modify LD property ( try to change disk cache and the help balloon refers to VD)(DCSG00324759)
 -SPDM_LSA : There is no successful message displayed for the export CSR action.(DCSG00122457)
 -Memory Leak issues LSA Build(DCSG00149688)
 -Port Box Bay info incorrect for ISE operation page(DCSG00092895)
 -The "More Actions" menu doesn't open up when the RAID controller is ESRT2(DCSG00259353)
 -Enclosure Bay count coming Wrong in(DCSG00074661)
 -Updated Arm read me file with arm specific changes(DCSG00085797)
 -LSA Property: package version mismatch between components in IT(DCSG00307461)
 -Test Configuration button should be disabled till we get the response(DCSG00299771)
 -LSA Client: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00129756)
 -LSA MR 7.16: Not able to modify the VD size in Advanced configuration page.(DCSG00381677)
 -multi-LUN tool support for multi-actuator drives.(DCSG00122386)
 -Shenandoah_MRSA : Number of hours is wrong in MRSA evetns for Event 544(DCSG00325891)
 -LSA Client: Manage Link Speed not showing the error message(DCSG00310339)
 -Manual Discovery failure shouldn't return HTTP status:200(DCSG00098024)
 -LSA Common: Package 64 bit monitor libraries as part of Windows x64 package(DCSG00307031)
 -Shenandoah_MRSA: Enclosure Type in Server profile is not complete. Needs to allign with CLI(DCSG00081768)
 -LSA: MR-7.14-SPDM tab needs correction.(DCSG00108295)
 -LSA: "Incorrect Connector Name" under physical drive properties.(DCSG00358747)
 -LSA Common: Stale folders still persist in html folder(DCSG00388225)
 -fixed: import of certificate issue(DCSG00094369)
 -Not able to launch MRSA though the launch icon or installer(DCSG00078194)
 -LSA MR 7.15 Alpha : Schedule consistency Check field is showing partially degraded VD as optimal.(DCSG00263547)
 -Event strings not proper in MRSA for 379,383,385(DCSG00325883)
 -Junk characters are getting displayed in enclosure information with no drives connected.(DCSG00074730)
 -LSA MR 7.16: Filter option is not working properly in RLM page.(DCSG00342455)
 -PCI-Switch subtype when enclosure is an pci-switch(DCSG00085935)
 -Predicitive Failure count and Drive temperature not getting updated in PD property page(DCSG00082823)
 -Windows OS crashes after upgrading to LSA 007.014.005.000(DCSG00138044)
 -Shenandoah_MRSA: Controller Drop down not listing all controllers(DCSG00108923)
 -LSA - ICX - Lane speed under Manage PCIe storage interface is showing like 2.5GT, 5GT, 8GT instead of 2.5GT/s, 5GT/s, 8GT/s(DCSG00259499)
 -fixed: Min VD size check for R1 was missing(DCSG00086324)
 -fixed: MFI code stops LSA from showing slot 0 and 1 when it is not configured(DCSG00123067
 -WG 7.14 PA:During the Creation of r60 vd , removal/adding drives creates inconsistency in AddPhysicalDrive and Addhotspare tables.(DCSG00079935)
 -"Compare and Select" page shows Raid 6 with 3 drives(DCSG00087244)
 -Current speed under "Manage SAS storage link speed" is showing like 3Gb, 6Gb, 12Gb instead of 3Gb/s, 6Gb/s, 12Gb/s(DCSG00301640)
 -Drives connected to IT controller reports Shield Counter(DCSG00264740)
 -WG: RWC3 windows build loads with http, instead of https(DCSG00340881)
 -WG 7.14 PA2: Stripe size under DG does not sort properly when multiple Vds are created with different strip sizes.(DCSG00093774)
 -LSA_SPDM : Import certificate chain event id 622 description is not proper.(DCSG00122482)
 -WG MR 7.14 PA1: LSA allows to select 512B drives as DHSP for 4K DG(DCSG00078853)
 -Backplane info is not proper in expanded state(DCSG00106485)
 -Shenandoah_MRSA : Transport feature needs to be removed from array properties(DCSG00081965)
 -Fixed: update approved user list(DCSG00384488)
 -Fixed: Import certificate /Download CSR options are disabled for slot 0 & 1(DCSG00138892)
 -Aero MR : LSA Channel: Drive connector information not displayed correctly when compared with Storcli output(DCSG00416118)
 -Fixed: changed values to comply with schema restrictions(DCSG00140179)
 -LSA WG : LSA "Download Diagonstic" field is not downloading the ttylog in Readonly access.(DCSG00083816)
 -LSA - Error code 169 - Description Shows as Blank.(DCSG00111872)
 -Credits page needs an update(DCSG00232932)
 -WG:LWA:Not all snapdump logs are downloaded on trying to download all the generated snapdump logs(DCSG00216125)
 -MR 7.16 Aero: Storcli displays Enclosure Serial Number as blank whereas LSA shows as "N/A"(DCSG00316066)
 -Fixed: permission of only last node in path was changing(DCSG00384372)
 -After the upgrade or trying to delete through RPM launch Icon is not deleted(DCSG00078205)
 -Fixed: issue resolution message for non-recoverable drive(DCSG00105032)
 -Port information is wrong when SAS drive is connected to UBM3 BP with 416A controller(DCSG00316863)
 -Fixed: enclosure type and subtype display changes for PCI-switch(DCSG00314948)
 -Remove the individual elements download from MRSA(DCSG00418470)
 -WG: LSA does not allow to change to any other behavior once encountering error during behavior change : GUI Change(DCSG00255157)
 -MR 7.15: LSA fails to launch in Ubuntu.(DCSG00221326)
 -JBOD creation is not allowed through MRSA both on windows and Linux on 7.16 builds(DCSG00317915)
 -Shenandoah_MRSA:Enclosure type not correct for UBM4 backplanes in server profile(DCSG00360535)
 -WG MR 7.16 : Direct agent and standalone does not load on Ubuntu ARM system.(DCSG00395624)
 -Spacing issues on securing a DG as secure, minor GUI issue non notification of enabling scsiUnmap(DCSG00138886)
 -Unable to uninstall the RWC3 on Ubuntu 20.4 when xterm present(DCSG00146748)
 -WG 7.14:During VD creation filtering 4k drives displays blank PD table when mixing is not allowed(DCSG00078974)
 -WG 7.14 PA2: "Unlock" button should be grayed out for Foreign secured locked PD.(DCSG00094756)
 -LSA MR 7.16: Inconsistency while upgrading the LSA.(DCSG00417467)
 -Shenandoah_MRSA: Virtual disk reference in " Make Drive Online" option(DCSG00306847)
 -LSA MR 7.15: Not able to remove the manually added servers.(DCSG00239878)
 -Legacy: LSA WG: In home page, Scroll up option is missing when user expands the Server profile.(DCSG00083860)
 -MR Controller Downloaded Diagnostic Data has Deviceid set to 0 in line number 12(DCSG00125594)
 -fixed: R1 migration form R0 with one UG-good PD(DCSG00312113)
 -WG: RWC3 Ubuntu Linux build shows LSA instead of RWC3 during installation.(DCSG00385902)
 -Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys(DCSG00420399)
 -LSA MR 7.16: VD is expanded to 100%, when user provide the expansion percentage value between 0.1 to 0.5(DCSG00303650)
 -Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down(DCSG00080854)
 -Uninstall the RWC3 does not remove the complete folder structure(DCSG00125612)
 -WG: empty enclosure ID and slot ID is displayed for NVMe initialization event in event logs(DCSG00105113)
 -SAS address is shown for PCIe (NVME) drives instead of WWID(DCSG00138744)
 -Health status changes of the remote server does not get updated in the gateway remote discovery page(DCSG00086628)
 -Shenandoah: MRSA events for enclosure insertion not in sync with firmware logs(DCSG00303613)
 -LSA is showing wrong "LSA_lib_utils" version while uninstalling in linux.(DCSG00083760)
 -WG 7.14 PA2:managed server icon for self server is shown "add" in manage server page if we add ubuntu/ any server to manage server list.(DCSG00112829)
 -WG: Instance validation fails for Configuration service GET, LSA build : MR 7.14, 7.014.000.000(DCSG00079959)
 -LSA MR 7.15: Reload option should not be available in Remote discovery page.(DCSG00235388)
 -Shenandoah: MRSA: keyType information wrong in MRSA for event 343(DCSG00333167)
 -Whitley ICX : LSA - Add physical drives option is not coming for user when trying to recon from R6 to R0(DCSG00104470 (Port Of Defect DCSG00105105)
 -7.14: Update read me files(DCSG00221381 (Port Of Defect DCSG00226031)
 -Handling Manual Discovery ADD case(DCSG00077625 (Port Of Defect DCSG00101928)
 -behavior mode values is not being set properly(DCSG00426348 (Port Of Defect DCSG00426351)
 -AV_RAID_MODE:Missing drive info not displayed when performed on PDs of multiple DGs(DCSG00411847 (Port Of Defect DCSG00415015)
 -LSA_Server: Mismatch in "disk cache policy" during VD creation and after VD creation(DCSG00404783 (Port Of Defect DCSG00408997)
 -LSA uninstallation is failing on HPE(DCSG00164985 (Port Of Defect DCSG00164991)
 -"delete config" command clears the config, when OS/FS in the drive without "force" option.(DCSG00077464 (Port Of Defect DCSG00101933)
 -WG: Instance validation fails for PHY's GET and phy/0 GET (MR 7.13, 7.013.004.000)(DCSG00066942 (Port Of Defect DCSG00078972)
 -CSET Port of Defect DCSG00078494: Lone LF in body of email message(DCSG00078494 (Port Of Defect DCSG00078973)
 -Connected device under "Manage PCIe storage interface" is not showing any NVMe drive details(DCSG00302010 (Port Of Defect DCSG00314950)
 -Fixed: updated configured PD to include offline and failed drives(DCSG00382593 (Port Of Defect DCSG00404817)
 -WG: Manually added VMware server continues to show and does not get auto discovered.(DCSG00243976 (Port Of Defect DCSG00312021)
 -LSA : Modify properties option is not coming to user for CC VD using 730-8i controller(DCSG00408495 (Port Of Defect DCSG00415046)
 -Fixed: Parameter 16GT is not visible while updating lane speed(DCSG00255550 (Port Of Defect DCSG00421350)
 -LSA Server: Manual discovery fix(DCSG00246091 (Port Of Defect DCSG00312023)
 -WG: VMware user able to download LSA logs of gateway(DCSG00384359 (Port Of Defect DCSG00395338)
 -LSA Conf: Clean and remove unused fields(DCSG00297566 (Port Of Defect DCSG00347725)
 -On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04(DCSG00105871 (Port Of Defect DCSG00137404)
 -update HBA 440-16i UEFI BSD failed via LSA(DCSG00074275 (Port Of Defect DCSG00101747)
 -LSA Client: Manage Link Speed not showing the error message(DCSG00310339 (Port Of Defect DCSG00310340)
 -Changing the ngroups list values(DCSG00102619 (Port Of Defect DCSG00103258)
 -LSA Property: package version mismatch between components in IT(DCSG00307419 (Port Of Defect DCSG00312026)
 -LSA Client: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00129756 (Port Of Defect DCSG00152277)
 -LSA_Avenger: Modify VD properties page is not opening, when VD is created from Simple configuration.(DCSG00337910 (Port Of Defect DCSG00345130)
 -LSA Avenger: Sorting based on VD capacity is not working when VD with size more than 1 TB is present in DG(DCSG00321981 (Port Of Defect DCSG00335909)
 -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0(DCSG00063716 (Port Of Defect DCSG00065591)
 -LSA_Avenger: filtering and then sorting drives which are used in vd creation , drives table goes blank.(DCSG00354629 (Port Of Defect DCSG00363767)
 -LSA : Enable/Disable SSD caching is not working for all VDs at once if user selected multiple VDs and enabling/disabling SSD cache(DCSG00409275 (Port Of Defect DCSG00415052)
 -LSA report Power supply status only after LSA service restart(DCSG00086465 (Port Of Defect DCSG00102025)
 -PH15 LSA IT:In RHEL7.8 for enclosure drives Multi path field is showing as"Yes" In Physical Drive properties,without Multipath configuration(DCSG00132726 (Port Of Defect DCSG00138842)
 -MR7.15 Alpha (DBU) WG: unable to change the behavior mode to "none" on Aero controller(DCSG00278399 (Port Of Defect DCSG00312025)
 -CSET Port of Defect DCSG00355995: LSA imports all foreign configs while importing 240VDs, but it shows error message "The server could not import foreign configurations" (Error Code:2)(DCSG00355995 (Port Of Defect DCSG00395255)
 -Cisco - CSCvv26000: C240 M6 : Improper display of RAID5 VD size while creating VD through LSA in Zuma beach(DCSG00313412 (Port Of Defect DCSG00325945)
 -LSA- ICX : Profile properties shows that WB volumes support as "False" under controller Info(DCSG00254886 (Port Of Defect DCSG00278008)
 -MR 7.15 - LSA Event Log is showing Default Read Policy as Always Read Ahead ...needed to be "Read Ahead" instead(DCSG00299006 (Port Of Defect DCSG00307816)
 -Fixed: updated nginx and libcurl(DCSG00414394 (Port Of Defect DCSG00419679)
 -Shenandoah_MRSA: Controller Drop down not listing all controllers(DCSG00108923 (Port Of Defect DCSG00110220)
 -LSA Client : Handle Manual Discovery failure cases(DCSG00098052 (Port Of Defect DCSG00112023)
 -ICX_Whitley_Orion: LSA- Link speed details are not showing properly for Tape drive in WebGUI(DCSG00075777 (Port Of Defect DCSG00102597)
 -Manual discovery page gets hung while adding the server to Auto discovery list.(DCSG00080451 (Port Of Defect DCSG00102024)
 -WG:LSA provides controller operation option of starting patrol read when there are only raid 1 VDs created using NMVe PD's(DCSG00257688 (Port Of Defect DCSG00312024)
 -RWC3 for Windows breaks when testing email on SMTP Port 587(DCSG00298491 (Port Of Defect DCSG00307805)

EnhancementRequest:
 -LSA credits page update with latest open source components(DCSG00074643)
 -LSA Client: NVMe Drive Init failure Error Reporting(DCSG00085790)
 -LSA Server: NVMe Drive Repair - Handling Event(DCSG00086254)
 -Added the current Speed Column to phy and lane speed table(DCSG00075198)
 -MegaAPI: Add API changes for Support Parity Read Cache Bypass (PR: DCSG00245039)(DCSG00370441)
 -MR API: Change event class for SPDM events(DCSG00134416)
 -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI STAT(DCSG00222915)
 -LSA_Server: Fetch and Display Port name and Box number for NVMe drives with Init error/repair(DCSG00373455)
 -Update X-Content-Type-Options to Header(DCSG00342485)
 -LSA changes to implement the PR:DCSG00152043(DCSG00216430)
 -Restore Factory Default doesn't prompt user to reboot the system after being performed(DCSG00120443)
 -(DCSG00082479)
 -MR7 - LSA_Common: Support WJ Pinning for both WB and WT Parity RAID VDs(DCSG00214470)
 -API change to add connector index as part of NVMe Init Error drive information(DCSG00352896)
 -SPDM support changes(DCSG00092939)
 -LSA 64bit support - disconnect 32 bit(DCSG00243701)
 -Update Nginx Settings and allow download server report for admin users(DCSG00347344)
 -MegaAPI: Add Event for possibility of incomplete writes on parity VDs with no battery backup (ER: DCSG00229751)(DCSG00405671)
 -Support for Ubuntu v18.04 OS(DCSG00081316)
 -MFI SMP Port Num API changes(DCSG00257777)
 -Upgrade of OpenSLP source Code(DCSG00167228)
 -Warning events including Predictive failure (code 96) to add the new property to the drive(DCSG00074191)
 -Cleaning up LSA Readme file(DCSG00086337)
 -Major version upgrade of OpenSSL(DCSG00075194)
 -LSA Common: Enhance OEM build generation on Standalone server(DCSG00138907)
 -MR7.15: LSA - Linux 32 bit binary removal in Standalone Environment(DCSG00228734)
 -LSA Server: Enhance development environment to maintain OEM specific projects(DCSG00129446)
 -Add new security events(DCSG00167313)
 -Multi path Display Enhancement in the Client(DCSG00075193)
 -LSA_7.16: Enhance Make Release process(DCSG00339979)
 -Enhance LightWeightMonitor build process(DCSG00093307)
 -MR API: create a new DCMD for BMC to initiate an expander reset(DCSG00362825)
 -SMART Polling Improvement- API Changes(DCSG00214352)
 -LSA MR7.16: Ruby SED Support(DCSG00265657)
 -storcli does not show the SAS Address of the enclosure(DCSG00255107)
 -MR API: reclassify MR_EVT_CTRL_FW_VALID_SNAPDUMP_AVAILABLE as informational(DCSG00292323)
 -Eliminate reporting of capacitance over 100%(DCSG00149664)
 -Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10(DCSG00074194)
 -Updated 3rd party libs(DCSG00286594)
 -New MFI Stat for the updated recon behavior(DCSG00229416)
 -MegaAPI: rename WJ events and change event messages (PR: DCSG00166915)(DCSG00332867)
 -MegaAPI: Add API changes for Support WJ Pinning for both WB and WT Parity RAID VDs (PR: DCSG00166915)(DCSG00312334)
 -NVME Failed drive error reporting(DCSG00085936)
 -System Health Status update in case of multiple controllers present in system.(DCSG00075224)
 -(DCSG00082474)
 -MR7 API: Add package incompatibility reporting(DCSG00231443)
 -MegaAPI: Add API Controller Properties and MFCD for ParityReadCacheBypass (PR: DCSG00237022)(DCSG00282676)
 -Manual Discovery Enhancements(DCSG00149397)
 -SPDM Support for Aero in LSA GUI(DCSG00076958)
 -Script build process for arm and esxi LSA(DCSG00075216)
 -LSA 64bit support - disconnect 32 bit(DCSG00243703)
 -Additional NameSpace behavior changes(DCSG00383671)
 -Add the Force Refresh for Cache module in LSA(DCSG00219527)
 -SMART Polling Improvement - API Changes(DCSG00246317)
 -To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h(DCSG00256271)
 -Additional FDE type for Ruby SED support(DCSG00055878)
 -LSA Client: NVMe Drive Repair(DCSG00085927)
 -Build Enhancement - Automate standalone build generation(DCSG00075220)
 -Populating port name of a UBM U.2/3 backplane with NVMe drives(DCSG00132390)
 -MR_SAS_PHY_LINK_SPEED should indicate that the link is not active(DCSG00073569)
 -MR7.16 - LSA Server: SAS Address and LogicalID fields missing in enclosure properties(DCSG00255108)
 -Optimize Server Report Generation(DCSG00351905)
 -LSAServer: Add the Force Refresh for Cache module in LSA(DCSG00218902)
 -Convert LSA installation scripts from csh to sh(DCSG00075219)
 -Remove bays on port for Shenandoah For MRSA(DCSG00101417)
 -LSA Common: NVMe Drive Repair - Event and MFI state notification(DCSG00086253)
 -Multi path Enhancement in the server(DCSG00071167)
 -Upgrade the Install Shield Version to 2020(DCSG00219077)
 -Optimize LSA Server code Compilation Time(DCSG00075222)
 -LSA Server: Autoconfig API Improvement(DCSG00212945)
 -Upgrade GWT from 2.8.1 to 2.8.2(DCSG00110240)
 -LSA Server: NVMe Drive Repair(DCSG00085947)
 -Enhance Standalone RWC3 build process(DCSG00124860)
 -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode(DCSG00151058)
 -Request to add checks (DevId, SubDevice Id) check prior to flashing(DCSG00396121)
 -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API(DCSG00226286)
 -(DCSG00152596)
 -Implemented: setting appropriate permission for files and directories(DCSG00351962)
 -LSA needs to add the new adapter name to the support matrix hence marking it to Small to update the support matrix in readme(DCSG00075062)
 -Upgrade of OpenSLL and its dependent components(DCSG00124493)
 -LSA Client - Optimize Client Compilation Time(DCSG00075225)
 -MR7 : Support WJ Pinning for both WB and WT Parity RAID VDs(DCSG00214471)
 -API change to replace enum declaration with U32.(DCSG00393987)
 -API changes for reporting missing cables(DCSG00313199)
 -Changes to support 16port connection to Expander with AeroIOC(DCSG00254845)
 -MR 7.16: Make environment to generate MRMON 64 bit libraries(DCSG00308331)
 -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security SPDM(DCSG00106380)
 -Updated 3rd party libs(DCSG00286594 (Port Of EnhancementRequest DCSG00384441)
 -LSA_Server: Display Write Cache Settings for PD(DCSG00366367 (Port Of EnhancementRequest DCSG00373491)
 -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00354847)
 -Updated 3rd party libs(DCSG00286594 (Port Of EnhancementRequest DCSG00306730)
 -LSA Server: RRB141 - Ensure that the SSD cache policy is changeable and the status information is correct(DCSG00171246 (Port Of EnhancementRequest DCSG00228742)
 -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00384509)
 -(DCSG00167228 (Port Of EnhancementRequest DCSG00167257)
 -LSAServer: Add the Force Refresh for Cache module in LSA(DCSG00218902 (Port Of EnhancementRequest DCSG00225933)
 -Crypto Erase option for Cryptographic Capable Drive(DCSG00373462 (Port Of EnhancementRequest DCSG00384657)
 -LSA: Linux 32 bit binary removal(DCSG00221416 (Port Of EnhancementRequest DCSG00363675)
 -Linux: Installer script improvement(DCSG00130050 (Port Of EnhancementRequest DCSG00230033)
 -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00384472)
 -LSA_Common: Fetch and Display Port name and Box number for NVMe drives with Init error/repair(DCSG00373455 (Port Of EnhancementRequest DCSG00373474)
 -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00384513)
 -(DCSG00075222 (Port Of EnhancementRequest DCSG00081005)
 -(DCSG00098812 (Port Of EnhancementRequest DCSG00105863)
 -LSA: Linux 32 bit binary removal(DCSG00221416 (Port Of EnhancementRequest DCSG00408121)
 -SPDM support changes(DCSG00092939 (Port Of EnhancementRequest DCSG00113254)
 -BST Automation for LSA(DCSG00098812 (Port Of EnhancementRequest DCSG00218817)
 -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00354907)
 -CSET Port of EnhancementRequest DCSG00075194: Major version upgrade of OpenSSL(DCSG00075194 (Port Of EnhancementRequest DCSG00083924)
 -MR7.15: LSA - Linux 32 bit binary removal in Standalone Environment(DCSG00228734 (Port Of EnhancementRequest DCSG00293989)
 -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00348015)
 -CSET Port of EnhancementRequest DCSG00075194: Major version upgrade of OpenSSL(DCSG00075194 (Port Of EnhancementRequest DCSG00083925)
 -Added support for RHEL 8.3(DCSG00373404 (Port Of EnhancementRequest DCSG00428563)
 -(DCSG00096553 (Port Of EnhancementRequest DCSG00110100)
 -(DCSG00085947 (Port Of EnhancementRequest DCSG00086469)
 -(DCSG00286594 (Port Of EnhancementRequest DCSG00290207)
 -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00384205)
 -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00384206)
 -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00385127)
 -Ensure that the SSD cache policy is changeable and the status information is correct(DCSG00214163 (Port Of EnhancementRequest DCSG00230031)
 -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00384499)
 -(DCSG00286594 (Port Of EnhancementRequest DCSG00286739)
 -LSA_client: Display Write Cache Settings for PD(DCSG00372331 (Port Of EnhancementRequest DCSG00383405)
 -Added support for RHEL 8.3(DCSG00373404 (Port Of EnhancementRequest DCSG00428561)
 -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00366266)
 -Crypto Erase option for Cryptographic Capable Drive(DCSG00369727 (Port Of EnhancementRequest DCSG00384592)
 -WebGUI: Automate the test cases specific to MR7.14 Product Requirements(DCSG00082499 (Port Of EnhancementRequest DCSG00086646)
 -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00384514)


007.013.016.000 - Moderate Impact
---------------
MR 7.13

Defects:
-Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down.(DCSG00112141 (Port Of Defect DCSG00080854))
-Legacy : WG: LSA auto logs in on clicking "verify" button for "Managed" VMware manually added server in managed server page.(DCSG00112744 (Port Of Defect DCSG00112178))
-MR controller with No Alram is not auto refreshing on changing the controller properties.(DCSG00124768 (Port Of Defect DCSG00124484))
-LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings.(DCSG00136282 (Port Of Defect DCSG00134600))
-LSA Server: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state.(DCSG00219183 (Port Of Defect DCSG00114253))
-LSA WG : LSA "Download Diagonstic" field is not downloading the ttylog in Readonly access..(DCSG00219184 (Port Of Defect DCSG00083816))
-Secured foreign locked VDs details are not displayed under foreign configuration to import/clear foreign config.(DCSG00221295 (Port Of Defect DCSG00103239))
-Credits page needs an update.(DCSG00233292 (Port Of Defect DCSG00232932))
-WG 7.14 PA2: Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 7.8.(DCSG00233700 (Port Of Defect DCSG00092841))
-On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04.(DCSG00233701 (Port Of Defect DCSG00105871))
-Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2.(DCSG00233702 (Port Of Defect DCSG00115253))
-MR Controller Downloaded Diagnostic Data has Deviceid set to 0 in line number 12.(DCSG00233703 (Port Of Defect DCSG00125594))
-LSA 7.14 : Clicking on "Configure" option from server landing page is redirecting to controller info page instead of Advanced config page..(DCSG00233704 (Port Of Defect DCSG00125950))
-fixed: changed unit to Byte in case of zero size drives.(DCSG00233705 (Port Of Defect DCSG00072680))
-Non-interactive/silent installation does not have options to install LSA based on EVENT NOTIFICATION CHOCIES..(DCSG00233706 (Port Of Defect DCSG00078199))
-WG MR 7.14 PA1: LSA allows to select 512B drives as DHSP for 4K DG.(DCSG00233708 (Port Of Defect DCSG00078853))
-WG 7.14:During VD creation filtering 4k drives displays blank PD table when mixing is not allowed.(DCSG00233709 (Port Of Defect DCSG00078974))
-LSA Client: Behavior mode parameters is not shown.(DCSG00233710 (Port Of Defect DCSG00079966))
-VDs of different capacities(MB/GB) is not sorting properly..(DCSG00233711 (Port Of Defect DCSG00080102))
-Legacy: LSA WG: LSA is allowing to change the personality mode of the controller in Non-admin access..(DCSG00233712 (Port Of Defect DCSG00083219))
-Silent installation with default Web server port and default LSA port is failing..(DCSG00233713 (Port Of Defect DCSG00092962))
-WG 7.14 PA2:managed server icon for self server is shown "add" in manage server page if we add ubuntu/ any server to manage server list..(DCSG00233714 (Port Of Defect DCSG00112829))
-LSA WG : Uninstall instructions mentioned in LSA ESXi readme is wrong..(DCSG00233716 (Port Of Defect DCSG00126899))
-Manage server page throws error message "400:" for invalid credentials..(DCSG00233717 (Port Of Defect DCSG00136334)
-WG: LSA Does not have filter button in drives tab for IT controller Controller console page.(DCSG00233718 (Port Of Defect DCSG00138885))
-Fixed: Spanned drive min vd check calculation error.(DCSG00233720 (Port Of Defect DCSG00138063))


007.013.014.000 - Moderate Impact
-------------------------------------
MR 7.13

Defects:
 -WG 7.13:Inconsistency in display of "Patrol Read" in the Properties page.(DCSG00071276)
 -Changing the ngroups list values.(DCSG00102619)
 -Shenandoah_MRSA : change personality option should not be enabled for both with linux and windows releases.(DCSG00072698)
 -Whitley ICX : LSA - Add physical drives option is not coming for user when trying to recon from R6 to R0.(DCSG00104470)
 -Fixed: Added disable nginx logging flags.(DCSG00065714)
 -Memory Leak issues in LSA Build.(DCSG00068484)
 -WG: Alignment issues in Remote discovery page, server summary page and Settings page.(DCSG00065480)
 -IT controller is not displayed int the view all controllers tab when it is in needs attention.(DCSG00061513)
 -Manual discovery page gets hung while adding the server to Auto discovery list..(DCSG00080451)
 -WG: Clicking on Manually added server in manage server page leads to blank page (calls fails with 502 error code).(DCSG00063209)
 -LSA: disableOffloadNum field should be match with latest schema.(DCSG00041224)
 -Channel controllers are discovered from MRSA Software.(DCSG00054278)
 -Fixed: user notification client list is not updated.(DCSG00053648)
 -WG 7.13: Hot spare Filter box alignment issue.(DCSG00067986)
 -LSA Common: LSA Crypto OEM specific changes.(DCSG00047290)
 -Windows installer (7.013.004.000) is unsigned.(DCSG00065620)
 -Cannot update CFF 440 FW with LSA.(DCSG00062602)
 -Firmware update page shows "None" for selected firmware.(DCSG00065566)
 -Orion MR PA10 - Foreign config is not showing properly in LSA when user pull/push the PD.(DCSG00053829)
 -due to unhanded battery removal event, battery health status was not reflecting as need attention.(DCSG00040271)
 -WG: Energy pack details does not load on clicking energy pack properties after clicking Refresh energy pack properties.(DCSG00058132)
 -MR7.13: Enhance debug Log level and entries in LSA Common code.(DCSG00041751)
 -Fixed:display of 2 enclose when only one is connected with multi path.(DCSG00069728)
 -LSA MR: Hand symbol is showing for all the fields in Server Profile and it is not clickable.(DCSG00062470)
 -WG: In presence of JBOD, after creating VD using all UG drives, the advanced configuration button gets disabled.(DCSG00065733)
 -update HBA 440-16i UEFI BSD failed via LSA.(DCSG00074275)
 -MRSA Firmware update page shows ,Selected Firmware Package version and it shows Firmware version.(DCSG00051098)
 -WG: Instance validation fails for Enclosure GET( MR 7.13, 7.013.004.000.(DCSG00066930)
 -MR-7.12: LSA VD creation failure message has spacing formatting issue..(DCSG00037910)
 -LSA Client : Non-VMware server is discovered with VMware check box enabled in Manual Discovery.(DCSG00051290)
 -Partial degraded VD icon is showing as optimal VD icon in LSA.(DCSG00054282)
 -WG: Duplicate entries of physical drive properties are displayed in case a property of physical drive is updated.(DCSG00069285)
 -WG 7.13: Patrol read option not seen for GHS in LSA.(DCSG00068977)
 -WG: Instance validation fails for Controllers GET (MR 7.13, 7.013.004.000), : Aero Controller.(DCSG00067932)
 -Remote discovery fails to load in RWC3 (7.013.009.000.(DCSG00083835)
 -Fixed: usage of wrong enum led to unknow characters in max lane width.(DCSG00049771)
 -WG: For the self server adding a read only user in manage-server page is logged in as a admin user.(DCSG00065605)
 -AMD 2P - LSA is not showing proper information when user trying to do RLM with same RAID level.(DCSG00040578)
 -MR 7.13 DBU: Flashing BIOS package failure with Completed status on Aero Controller when selected EFI-BSD.(DCSG00055757)
 -Windows Un-installer is not removing the SL Debug logs.(DCSG00054660)
 -WG MR7.13: LSA read me file needs to be updated with New OS matrix and inclusion of Aero cards.(DCSG00055714)
 -WG: Refresh energy pack properties displays error notification with status code : 1 on Vmware login.(DCSG00058321)
 -Notification for Enable /Disable security box is not pointing to Enable/Disable security option..(DCSG00067992)
 -LSA Server: LSA Crypto OEM specific changes.(DCSG00047618)
 -Handling Manual Discovery ADD case.(DCSG00077625)
 -LSA is not allowing user to change max number of PDs allowed under Set Patrol Read properties.(DCSG00068620)
 -Negotiated width and Max lane width property parameters for Nvme drives is shown as "Max user count reached" in LSA.(DCSG00046456)
 -Unmap property not update in VD/PD on enabling/disabling unmap at controller level.(DCSG00040172)
 -Server Profile _Linux: enclosure/Backplane information is blank / ServerIP is private in Linux OS.(DCSG00072694)
 -key board short cut does not work after using the print button during the installation.(DCSG00064684)
 -MR-7.13: LSA event ID 614 shown as Blank..(DCSG00037968)
 -WG: Changes required in naming convention of LSA to RWC3 in linux installation, RWC3 end user text has junk unicode characters in place of quotes and typo's.(DCSG00058406)
 -LSA_ 32 bit installer fails to launch in RHEL 8.1.(DCSG00087274)
 -Shenandoah:MRSA- Online Help gives 404 Not Found.(DCSG00051063)
 -Manage SAS Storage Link Speed/Premium feature/Manage Pcie Storage Interface operations have missing table borders & issues pertaining to column separators of the table.(DCSG00068937)
 -LSA MR : Each box in the List view of server page shows handsymbol but it is not clickable.(DCSG00062228)
 -RWC3 Common: Updating x64 nginx file.(DCSG00068595)
 -WG: clickable Checkboxes and "Confirm" notification texts does not have clickable mouse hover hand icons.(DCSG00069230)
 -LSA Client : NVMe Drive property changes w.r.t schema v32.(DCSG00079364)
 -MRSA shows " 0 Needs attention " when controller health status is "Needs attention ".(DCSG00056573)
 -WG: No LSA support logs generated with 7.013.003.00 linux Gateway.(DCSG00059955)
 -Orion MR PA10 - Same RAID level migration throws an error in LSA if user adding and removing any drives.(DCSG00053821)
 -Enhance the message of locked foreign can not be imported to cover boot time password skip.(DCSG00071157)
 -LSA Client : disableOffloadNum field should be match with latest schema.(DCSG00053497)
 -LSA Server: Resolving merge issues.(DCSG00032674)
 -Fixed:handled discovering multiple controllers.(DCSG00024769)
 -AMD 2P Wave2: LSA- Not able to create RAID00 with more than 32 PDS.(DCSG00042409)
 -Lone LF in body of email message.(DCSG00078494)
 -LSA is getting timed out while creating R6-64 VDs using 32 PDs.(DCSG00049772)
 -AMD2P-Wave2- LSA: Same RAID level migration throws an error in LSA if user adding and removing any drives.(DCSG00068647)
 -Ventura MR FW: Push Pull of drives showing wrong Enclosure ID..(DCSG00060541)
 -WG: Few of the keyboard shortcut keys are not working in case of RWc3 installation.(DCSG00058142)
 -MR-7.13: LSA Foreign import button not grey out after import is clicked with 240 VDs..(DCSG00068136)
 -StorCLI and LSA are not in sync while displaying the NVMe drive model Number after inserting the drive back..(DCSG00054602)
 -WG: Instance validation fails for PHY's GET and phy/0 GET (MR 7.13, 7.013.004.000.(DCSG00066942)
 -Use NVRAM to save PTB information -- API changes.(DCSG00082981)
 -Issue found due to code merge during code delivery process.(DCSG00075210)
 -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424)
 -MRSA: Supported controller information in the Readme File needs to be updated.(DCSG00056669)
 -Enter Key issue in Manual Discovery page is searching the servers without entering the IP..(DCSG00071404)
 -WG: For the self server which will be added to managed server by default should not show verify button.(DCSG00068954)
 -ICX_Whitley_Orion: LSA- Link speed details are not showing properly for Tape drive in WebGUI.(DCSG00075777)
 -"delete config" command clears the config, when OS/FS in the drive without "force" option.(DCSG00077464)
 -RWC3 windows build (07.013.009.000)loads with http instead of https.(DCSG00083839)
 -LSA MR Ventura: Alarm info is showing wrong when controller info tab is expanded..(DCSG00062219)
 -LSA report Power supply status only after LSA service restart.(DCSG00086465)
 -WG: LSA install shield says ready to install "OpenSLP 3.0.0.0 Arm64" instead of "openSLP 2.0.0.0 x86".(DCSG00063219)
 -Channel controllers are discovered from MRSA Software.(DCSG00053971)
 -Fixed: updated max drives for configuration service API.(DCSG00045337)
 -WG: Issues pertaining to schedule consistency check.(DCSG00069219)
 -Fixed: used data drives instead of total drive whie calculating min vd size.(DCSG00033996)
 -Orion_LSA: Maddux_Chinook: Slot numbers shown as 255 after expander resets.(DCSG00045472)
 -Fixed: Added minimum log support for thin OS.(DCSG00058212)
 -Display of unmap property at VD level.(DCSG00037620)
 -After installation of HPE_Generic linux 64 bit RPM, LSA service is not getting started..(DCSG00056838)
 -WG: Typo's in Readme and LSA.conf.(DCSG00058412)
 -Typo's in LSA.conf.(DCSG00061049)
 -WG: Copyright info needs to be updated from 2019 to 2020.(DCSG00068495)
 -LSA Readme file has to be updated for Aero controller support and proper open SLP web link..(DCSG00054273)
 -Inconsistency in the Server profile Headline representation.(DCSG00068909)
 -WG: Manual discovery page allows the user to add already added manually added VMware server.(DCSG00059470)
 -LSA Server: RAID volume creation failing with strip size conversion.(DCSG00048632)
 -LSA Client : Slot numbers shown as 255 after expander resets.(DCSG00055108)
 -LSAServer: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00008078 (Port Of Defect DCSG00025255))
 -Ubuntu Linux install issues.(DCSG00032286 (Port Of Defect DCSG00033488))
 -LSA does not display Virtual drive info for foreign configuration.(DCSG00035555 (Port Of Defect DCSG00071356))
 -Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down.(DCSG00080854 (Port Of Defect DCSG00112141)
 -Fixed:LSA increased memory consumption with each event.(DCSG00031835 (Port Of Defect DCSG00070333))
 -Fan, Temperature Sensor , Voltage Sensor property issues related to Atlas board.(DCSG00035711 (Port Of Defect DCSG00071360)
 -Credits page needs an update.(DCSG00232932 (Port Of Defect DCSG00235896))
 -LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings.(DCSG00134600 (Port Of Defect DCSG00136282))
 -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0.(DCSG00063716 (Port Of Defect DCSG00065590))
 -When create or delete VD in LSA, VD information didn't refresh under LSA web in VMWare 6.7.(DCSG00068509 (Port Of Defect DCSG00069274))
 -LSA getting hung while loading in windows 2019 OS on Stonyford server.(DCSG00058328 (Port Of Defect DCSG00058797)
 -Health status changes of the remote server does not get updated in the gateway remote discovery page.(DCSG00086628 (Port Of Defect DCSG00087296)
 -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424 (Port Of Defect DCSG00071283))
 -RWC3 Home Page Help Button Hyper Link is Broken.(DCSG00050748 (Port Of Defect DCSG00061255))
 -LSA Client : Handle Manual Discovery failure cases.(DCSG00098052 (Port Of Defect DCSG00098056)
 -Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2.(DCSG00115253 (Port Of Defect DCSG00239461)
 -LSA read me: Update the read me with all the required OS list.(DCSG00222589 (Port Of Defect DCSG00239476))
 -When selected 6272 KB firmware for update failure seen with message as file is more than 16MB size.(DCSG00080838 (Port Of Defect DCSG00102801))
 -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424 (Port Of Defect DCSG00070664)
 -Manual Discovery failure shouldn't return HTTP status:200.(DCSG00098024 (Port Of Defect DCSG00098034)
 -MR controller with No Alram is not auto refreshing on changing the controller properties.(DCSG00124484 (Port Of Defect DCSG00124768))
 
 EnhancementRequests:
 -Support for the New Energy Pack states.(DCSG00042776)
 -Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG.(DCSG00105430)
 -API change to support ISE completion status.(DCSG00065881)
 -MR API: Change event class for SPDM events.(DCSG00134416)
 -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI STAT.(DCSG00222915)
 -LSA Standalone - port enhanced authentication/authorization to Linux.(DCSG00025327)
 -DCSG00234646
 -HPE Shenandoah: Type 2 Back plane Support.(DCSG00054712)
 -Linux: Installer script improvement.(DCSG00130050)
 -Remove Span setting for RAID 1 & 10.(DCSG00039596)
 -Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713)
 -MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534)
 -Implement support for Cross certificate and command - Windows signing using CNG Provider with HSM Protected Key.(DCSG00030211)
 -Allows cleaner exit with flushing of logs.(DCSG00039065)
 -DCSG00129388
 -DCSG00067060
 -Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066)
 -Enhance debug Log level and entries in LSA Server code.(DCSG00038025)
 -Signing Linux executables via GPG method in HSM.(DCSG00077215)
 -Implemented: Logs levels appropriated.(DCSG00038028)
 -MR7.13: Enhance debug Log level and entries in LSA Server code.(DCSG00038019)
 -Request to change all BBU messages to CacheVault or Energy PAck as appropriate, since no longer supporting BBUs on latest Ventura products.(DCSG00031355)
 -Implemented secureSignCNG.exe CLI signing tool for Windows Signing..(DCSG00023491)
 -Blocking Management and display of the profile and Personality in MRSA as user can not change profile or personality from MRSA.(DCSG00041350)
 -SSD Wear Gauage.(DCSG00042810)
 -MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355)
 -Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780)
 -Update RAID Web Console 3 solution to remove or re-direct Feedback.(DCSG00026525)
 -Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00214163)
 -Port secureSignBin.exe for MARGAY signing to GCP server environment.(DCSG00040377)
 -MR7.13: Enhance debug Log level and entries in LSA Server code.(DCSG00038027)
 -Request to change all BBU messages to CacheVault or Energy PAck as appropriate, since no longer supporting BBUs on latest Ventura products.(DCSG00031716)
 -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058)
 -MR7.13: Enhance Server report log collection.(DCSG00039063)
 -HPE Shenandoah: Type 2 Back plane Support MRSA Client.(DCSG00054716)
 -Add new security events.(DCSG00167313)
 -Upgrade Install shield 2019.(DCSG00039535)
 -Support for the New Energy Pack states.(DCSG00042778)
 -LDET - Qx-2020 - RRB149 - Add immediate-binding flag to gcc-compiled deliverables.(DCSG00025854)
 -MR API: update field in event structure..(DCSG00093331)
 -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286)
 -MR7.13 - LSA Client: Update Snapdump save count field in show snapdump command.(DCSG00039516)
 -Updated secureSign.exe CLI tool and server-side controller scripts to use GCP server resources.(DCSG00003371)
 -SMART Polling Improvement- API Changes.(DCSG00214352)
 -LSA Server: RRB141 - Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00171246)
 -FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event from Info to Warning.(DCSG00086780)
 -New MFI Stat for the updated recon behavior.(DCSG00229416)
 -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security SPDM.(DCSG00106380)
 -Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847)
 -MR7.13 - LSA Server: Update Snapdump save count field in show snapdump command.(DCSG00039505)
 -MR7 API: Add package incompatibility reporting.(DCSG00231443)
 -Aero multi-party signing partial signing of images.(DCSG00048670)
 -DCSG00025854 (Port Of EnhancementRequest DCSG00039673)
 -Multi path Enhancement in the server.(DCSG00071167 (Port Of EnhancementRequest DCSG00075640)
 -Linux LSA HSM based signing support.(DCSG00038899 (Port Of EnhancementRequest DCSG00042392))
 -Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00214163 (Port Of EnhancementRequest DCSG00240010))
 -LSA credits page update with latest open source components.(DCSG00074643 (Port Of EnhancementRequest DCSG00074715)
 -Windows LSA HSM based signing support.(DCSG00038808 (Port Of EnhancementRequest DCSG00042391)
 

NOTE TO SERVICE - Reference RETAIN #N/A
007.012.015.000  - Moderate Impact
-------------------------------------

Defects Fixed (100)
 -Fixed:LSA increased memory consumption with each event(DCSG00031835)
 -Scheduler Panel not aligned to center if Operations are performed on 32 VDs.(DCSG00016270)
 -Enable SSD guard fails with the error code : 3: Description: The requested command has invalid arguments.(DCSG00008031)
 -WG: Readme changes as part of MR 7.12.(DCSG00031356)
 -fixed: allow Cachecade VD creation.(DCSG00022978)
 -Aero DBU alpha (LSA):LSA crashes when make jbod/UG performed on multiple drives with Schedular wrapper enabled.(DCSG00024414)
 -7.12_EXT New OS support Matrix.(7.12_EXT New OS support Matrix).(DCSG00011435)
 -WG: Filtering with VMware and searching for auto discovered windows/linux server in manual disc page results in both success and failure messages.(DCSG00010481) 
 -fixed: nginx logs consuming large space on disk.(DCSG00032280)
 -WG:alignment issue in notifications.(DCSG00007250)
 -LSAServer: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00008078)
 -Hide the Energy pack information when it is not present.(DCSG00031701)
 -Uninstall successful message not seen with RHEL OS & install exists with unary operator message if user provides input other than Y/N.(DCSG00012335)
 -SLES 15 Linux: Installer messages while creating symbolic link.(DCSG00023294)
 -LSAServer: Cleanup unused variables from LSA Crypto algorithm.(LSAServer: Cleanup unused variables from LSA Crypto algorithm)
 -Fan, Temperature Sensor , Voltage Sensor property issues related to Atlas board..(DCSG00035711)
 -"Your connection is not private" text overlap seen at manage server page.(DCSG00017191)
 -StoreLib API: Update SL_GET_ENCL_LIST with cmdParam_1b[0] for extended/legacy enclosure structures.(DCSG00053982)
 -WG: Aero DBU PA6(LSA): Performing VD operations does not update/clear the element count.(DCSG00012010)
 -Fixed: changed packaging script appropriatley.(DCSG00011424)
 -LSA Cache update for PD insert for it ctrls.(DCSG00020315)
 -Login Button gets disabled when user name is filled and Authentication Fails.(DCSG00014659)
 -LSA install exits if the user clicks enter key on any point during installation.(DCSG00026178)
 -MR 7.12: LSA Client- Coverity Defect Fixes.(DCSG00028104)
 -Modify the Alert setting put request to send only delivery mechanism when Email is not modified.(DCSG00007449)
 -MR-7.12: FW EPD bit is enabled in RAID personality Mode..(DCSG00036066)
 -WG: Remote discovery page does not load with RWC3 gateway installation: MR 7.12.(DCSG00057422)
 -Fixed: library to communicate with vmware server for arm.(DCSG00010202)
 -LSAClient: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00012720)
 -SLES 15 Linux: Un-Installation is not removing the complete folder structure.(DCSG00023296)
 -fixed: show only eleigible Raid level for migration.(DCSG00025527)
 -WG_7.12: On SLES 15 OS, After login, on doing some basic operations LSA, it redirects to 50x.html.(DCSG00022866)
 -Refresh the Client page on Enclose link Restore and link lost.(DCSG00014979)
 -Resolved built time dependency.(DCSG00008091)
 -LSA Common:Enhance user notification about the unsecured connection.(DCSG00008073)
 -WG 7.12 Alpha:Jbod conversion is not happening with OS drive.(DCSG00031718)
 -WG: no notification regarding "EMAIL/SMTP server related setting get modified" when user hovers between mail server and Email tab while adding email.(DCSG00020145)
 -LSA - AMD 2P Wave 1 - LSA is getting crashed while upgrading from 007.012.004.000 to 007.012.005.000 version.(DCSG00022361)
 -WG:7.12 Alpha : Enable/disable Scsi Unmap option not shown for the VD created using unmap capable drive..(DCSG00026497)
 -LSA Linux: Maintain the resource files across the build upgrade.(DCSG00007897)
 -LSA Server : JBOD removal/insert events in LSA are not compliance with FW Events..(DCSG00032366)
 -(LSA):Facing " ./LSA: ./libssl.so.1.0.0: no version information available" error while LSA installation.(DCSG00022170)
 -Fixed: Simple configuration feature is disabled if unconfigured drives are not available.(DCSG00025334)
 -LSA Common: Update the script files specific to LSA Crypto.(DCSG00031407)
 -IR Client Refresh: On Start/Stop CC.(DCSG00017218)
 -Libutils and Libutils2 scripts changes.(DCSG00012770)
 -LSA does not display Virtual drive info for foreign configuration.(DCSG00035555)
 -WG: Windows Direct agent not getting discovered in remote discovery page as well as manual discovery page.(DCSG00009390)
 -LSA AMD2P Wave 1: User is getting wrong info about max number of PD support for R1/R5 while doing RLM.(LSA AMD2P Wave 1: User is getting wrong info about max number of PD support for R1/R5 while doing RLM)
 -Ubuntu Linux install issues.(DCSG00032286)
 -Fixed: Slpd supported for rhel/sles/ubuntu is packaged.(Fixed: Slpd supported for rhel/sles/ubuntu is packaged)
 -StoreLib header: Update comments in Topology structures for attached devices to Atlas.(DCSG00061230)
 -WG 7.12 Alpha: LSA continues to be in debug mode when "./LSA -" executed for configuring LWM alert settings.(DCSG00028583)
 -When create or delete VD in LSA, VD information didn't refresh under LSA web in VMWare 6.7.(DCSG00068509)
 -WG: non Generic Icon shown for IT in CC page, typo in batch failure notification, no notification for premium feature key above 40 character.(DCSG00027350)
 -WG: LSA -console enters an infinite loop on entering a character/string as input.(DCSG00008008)
 -LSA upgrade fails from 7.10 patch RO to 7.12 RO with ./deleteOldVersion.sh: line 79: ((: 009: value too great for base (error token is "009") in SLES 12 SP4.(DCSG00014016)
 -Client: Schema changes for lanes.(DCSG00010703)
 -LSA does not allow the user to configure alert settings.(DCSG00031332)
 -WG: MR 7.12 : Arm SLIR3 version is shown empty in view server profile.(DCSG00008006)
 -LSA - AMD 2P Wave1 - Same RAID level migration throws an error in LSA if user is not adding/removing any drives.(DCSG00028267)
 -LSA GUI display empty page when launching the app.(DCSG00014599)
 -LSA Server: Handle new MFI status in LSA.(DCSG00031865)
 -fixed: updated LSA version.(DCSG00008023)
 -LSA Server: Add MRMonMsg project to the LSA solution.(DCSG00007928)
 -Fixed: lane width is displayed as unknown.(DCSG00035811)
 -Schema changes for lanes.(DCSG00010702)
 -On ARM server during LSA upgrade, ./deleteOldVersion.sh: line 53: LSIStorageAuthority: command not found error is observed.(DCSG00025403)
 -WG: lsa.exe -console fails to execute with LWM installed on windows machine.(DCSG00007461)
 -ARM Ubuntu: Linux Uninstallation leaving slpd process alive.(ARM Ubuntu: Linux Uninstallation leaving slpd process alive)
 -WG: Manual discovery of the ubantu server from windows gateway lists it as VMware server, issue related to search and adding already discovered server.(DCSG00010474)
 -Fixed: Added aarch64 detection code for linux.(DCSG00008022)
 -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0.(DCSG00063716)
 -Even after LSA is uninstalled the LSA and Nginx port numbers are still busy, reinstallation requires using alternate free ports: Ubuntu.(DCSG00011517)
 -Address property Display mismatch for PD and Enclosure properties for MR and IT.(DCSG00017217)
 -LSA Server: External defect review:id=45919.(DCSG00007404)
 -For unconfigured bad drives, typo in Negotiated link speed & Drive speed in physical Drive properties page.(DCSG00007251)
 -Fixed: Resolved primary nic interface data population.(DCSG00010261)
 -LSA under Drives for IT controllers is showing selected elements 0 always.(DCSG00015834)
 -WG_7.12_LSA: Invalid VD size range notification is shown on entering VD capacity out of range.(DCSG00007446)
 -WG: Aero DBU Alpha(LSA): Select all snapdump --> deselect one of snapdump and then click on headline deselects all selected snapdumps.(DCSG00027305)
 -Fixed: missing span was not handled appropriately in DG health.(DCSG00027676)
 -WG: Mutliselect PD notification for IT controllers notifies user to select multiple Virtual Drive rows, clicking on FW version does not lead to FW update page.(DCSG00027320)
 -LSA crashes when clear drive operation performed.(DCSG00022528)
 -WG: during uninstallation of LSA from the control panel the publisher information is not shown in windows.(DCSG00042280)
 -Fixed: slpd didnt start durint startup.(DCSG00011426)
 -LSA Common: Handle events 610-613.(DCSG00008066)
 -Fixed: updated openssl library.(DCSG00010277)
 -WG:7.12:abort core dump seen for rekey operation on LSA..(DCSG00009381)
 -RWC3 Home Page Help Button Hyper Link is Broken.(DCSG00050748 Port Of Defect DCSG00057415)
 -WG: Copyright info needs to be updated from 2019 to 2020.(DCSG00068495 (Port Of Defect DCSG00068560))
 -DCSG00037620 (Port Of Defect DCSG00037685)
 -LSA Server: Resolving merge issues.(DCSG00032674 (Port Of Defect DCSG00032824))
 -LSA Readme file has to be updated for Aero controller support and proper open SLP web link..(DCSG00054273 (Port Of Defect DCSG00062969))
 -Add the language support matrix in to LSA readme.(DCSG00024412 (Port Of Defect DCSG00024705))
 -LSA IT : Not able to sort the drives based on drive "Model"..(DCSG00032171 (Port Of Defect DCSG00048474))
 -LSA getting hung while loading in windows 2019 OS on Stonyford server.(DCSG00058328 (Port Of Defect DCSG00058796))
 -LSA MR: VD(Raid5) status is showing as degraded, instead of offline..(DCSG00032167 (Port Of Defect DCSG00032180))
 -LSA show incorrect physical drive information, when drive push pull operation performed..(DCSG00026587 (Port Of Defect DCSG00026634))
 
 EnhancementRequests:
 -LSA Server:Add security-related compiling flags to LSA 3rd Party Components.(DCSG00010237)
 -Ubuntu support for RWC3.(DCSG00016264)
 -Enhance user notification about the unsecure connection.(DCSG00008000)
 -Linux LSA HSM based signing support.(DCSG00038899)
 -LSA Windows: Maintain the resource files across the build upgrade.(DCSG00021254)
 -Windows LSA HSM based signing support.(DCSG00038808)
 -API change to support 1. OEM specific UBM Back planes, and 2. Smart Battery state.(DCSG00040165)
 -Update MR API mr_drv.h to modify field for RTTRace_header.(DCSG00042985)
 -LSA Common:Add security-related compiling flags to LSA 3rd Party Components.(DCSG00010240)
 -API change OOB Self Diagnostics Design Improvements.(DCSG00054194)
 -LSA to handle the new error code populated by the SL IT.(DCSG00024064 (Port Of EnhancementRequest DCSG00024476))
 -DCSG00019108 (Port Of EnhancementRequest DCSG00019110).
 -DCSG00019108 (Port Of EnhancementRequest DCSG00019288).
 

007.010.016.000  - Moderate Impact
---------------
Defect:
 LSA MR: VD(Raid5) status is showing as degraded, instead of offline.(DCSG00032167)
 LSA IT : Not able to sort the drives based on drive "Model".(DCSG00032171)
 LSA does not display Virtual drive info for foreign configuration.(DCSG00035734 port of DCSG00035555)
 WG_7.12: On SLES 15 OS, After login, on doing some basic operations LSA, it redirects to 50x.html.(DCSG00026970 port of DCSG00022866)
 LSA 7.10 + Ubuntu Linux install issues.(DCSG00032287 port of DCSG00032286)
 Aero DBU alpha (LSA):LSA crashes when make jbod/UG performed on multiple drives with Schedular wrapper enabled.(DCSG00026968 port of DCSG00024414)
 nginx logs result in large disk space consumption.(DCSG00032285 port of DCSG00032280)
 SLES 15 Linux: Un-Installation is not removing the complete folder structure.(DCSG00027735 port of DCSG00023296)
 
EnhancementRequest Records Linked (4):
 New Event for firmware DMD handling
 StoreLib.h: Enhanced debug logging mechanism
 Storelib.h: Add new SL API SL_OOB_SET_TRANSPORT_TYPE to dynamically load SL in any oob mode
 API changes for Request to change all BBU messages to CacheVault.
 API changes needed for DPMstat support in MegaRAID SAS 3.5 controllers
 LSA 3rdParty :Add security-related compiling flags to LSA 3rd Party Components
 Automating Arm Builds


007.010.014.000 - Moderate Impact
---------------

Defects (277)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01874775)
 - Issues wrt the linux installer script(SCGCQ01879303)
 - WG: installing LSA on linux 64 bit machine throws an error " ‘/root/Desktop/LaunchLSA.desktop’: No such file or directory"(SCGCQ01897393)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01898255)
 - LSA Event ID 519 shows blank.(SCGCQ01901169)
 - Incorrect icon displayed along with "settings saved" message.(SCGCQ01905838)
 - LSA:Loading More data initially in BGOPS Progress bar in LSA and later Device ID disappears(SCGCQ01937373)
 - PH10 PA LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01940193)
 - WG: No Action Successful notification shown on Drive erase(single Drive)(SCGCQ01941129)
 - LSA 7.9: Mismatch of sector size string between PD table and Group name(SCGCQ01942630)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01949074)
 - LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01949090)
 - Linux binary not working.(SCGCQ01949665)
 - WG: String Changes related to VD operations, Filter blank box turn blue, expand backplane icon can be removed when drives=0(SCGCQ01960486)
 - Fixed: WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963966)
 - SmartCarrier Enclosure type shown as "vSES" in LSA(SCGCQ01965395)
 - : MRSA shows Bay Count as 255 under Enclosure / Backplane properties(SCGCQ01965427)
 - LSA:Add Logical drive Page give option to select"Cached IO" for an LD and Error message not Branding compliant(SCGCQ01965445)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01966275)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01966687)
 - WG:GUI issues:50x Html file,View server profile with no enclosure,View More of System messages, Restore Settings notification(SCGCQ01968404)
 - WG: GUI issues Pertaining to alignment of notification on scroll of LSA page	(SCGCQ01968457)
 - WG: LSA fails with the empty status description on trying to change the personality in presence of snapdump(SCGCQ01969570)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ01970007)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ01970452)
 - Port information missing under Enclosures List.(SCGCQ01972260)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01972673)
 - Reference to BBU in Server profile page(SCGCQ01976904)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ01976926)
 - Logical drives are listed in the GUI when all the drives are pulled out	(SCGCQ01976929)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01977769)
 - Fixed: Added check for missing drive case(SCGCQ01978914)
 - Fixed: LSA stops responding after creating Vd with 4k Drives(SCGCQ01978965)
 - VD/HotSpare reference in Clear Configuration Confirmation popup-Regression(SCGCQ01979076)
 - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01979137)
 - Error code is not displayed for DG add VD operation failure(SCGCQ01988209)
 - Modify array option available for Degraded R5 , Blank screen followed "0 drives" on removing drives(SCGCQ01988400)
 - Fixed: update Validation Check codes for the image file(SCGCQ01989969)
 - Aero A0: RWC3 does not show version of Selected Firmware Version for updating(SCGCQ01989970)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL(SCGCQ01993099)
 - Fixed: OS name for localhost is inconsistent with the Osname populated when discovered via slp(SCGCQ01994459)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ01998245)
 - Fix: WG: Intance validation for Controller Get fails : MR Ventura(SCGCQ01998299)
 - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998305)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02006229)
 - WG: Switching between view server profile and settings page would not load the view server profile(SCGCQ02007150)
 - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure (SCGCQ02009718)
 - LSA 7.9: Action successful notification is not seen for encrypting the DG(SCGCQ02010670)
 - LSA: Mismatch in Unconfigured Good string(SCGCQ02016646)
 - LSA: Patrol Read string display issue(SCGCQ02016879)
 - WG : LSA 7.9 Status code for Drive security disable message is showing same for StatusLevel 0 and 1(SCGCQ02018083)
 - Difference in naming of Array during Array creation(SCGCQ02019200)
 - WG: GUI issues pertaining to star/stop patrol read & remote discovery page(SCGCQ02019555)
 - Back-plane information showing as blank in server profile page.(SCGCQ02019592)
 - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02021372)
 - LSA : Updating FW pkg version is not shown during FW upgrade/downgrade.(SCGCQ02023284)
 - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02023407)
 - LSA 7.10:Unsupported drives are displayed as UG under server profile page.(SCGCQ02030950)
 - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further	(SCGCQ02032031)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ02032824)
 - Error message displayed for entering wrong password to unlock foreign VD/PD should be updated.(SCGCQ02034263)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02034466)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02035158)
 - WG: mouse hover icon missing for the connected device property column in manage link speed pane(SCGCQ02035223)
 - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02035226)
 - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02035317)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02035322)
 - WG: Selected element count does not get updated after auto page refresh when VD expand operation is performed(SCGCQ02036089)
 -(SCGCQ02036091)
 - WG: wrong notification shown on trying to unlock a foreign FDE drive with wrong passphrase and then with correct passphrase(SCGCQ02036701)
 - Aero DBU PA1:LSA-Issue pertaining to add hotspare while creating Vd(SCGCQ02038235)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02038386)
 - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW(SCGCQ02040516)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02040739)
 - Shenandoah_MRSA: Warning message improvement when tried to delete LD formatted with File System(SCGCQ02042555)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware	(SCGCQ02043781)
 - WG : LSA 7.10 Keyboard short cut keys are NOT there for Different pages of LSA Installation pages(SCGCQ02045646)
 - Fixed: OCR should trigger update of dual image components(SCGCQ02048856)
 - WG: Issues pertianing to set snapdump properties page--> enable disable snapdump and changing cache offload limit.(SCGCQ02048906)
 - WG: Incomplete foreign VD is seen when Clear foreign config is performed, incorrect status code on rescan after clear foreign(SCGCQ02049476)
 - WG:Securing JBOD option gets disabled if from list of JBODs selected even if one is unselected(SCGCQ02049479)
 - LSA displays one of the PD's is missing as part of foreign config even if all the PDs are connected(SCGCQ02049511)
 - WG: Few of VD and PD operations will not be usable in LSA without zooming out ((SCGCQ02049819(SCGCQ02049819)
 - WG: in presence of missing drive the select all and element count does not work properly in span drive tab(SCGCQ02050441)
 - WG 7.10:Advance controller info does not show whether energy pack is connected or not(SCGCQ02050502)
 - WG 7.10:Number of foreign config count is not updated if clear drive operation performed on a foreign pd.(SCGCQ02050579)
 - WG 7.10:Migration from r0 (31 pds(SCGCQ02050857)
 - Error and Warnings thrown while install/upgrade MRSA on SLES15(SCGCQ02053038)
 - WG: LSA notifications GUI issues & Other Hardware user info on expanding enclosure info, LSA conf file, Message_en file(SCGCQ02053156)
 - WG: UI Elements alignment for DG actions and Fixed action menu with lower resolution(SCGCQ02053167)
 - LSA Firmware package version shown as version in controller action page.(SCGCQ02053748)
 - LSA Simple configuration from main page shows blank when JBOD are present.(SCGCQ02053891)
 - Fixed: Last Vd size was not being checked for alignment(SCGCQ02058284)
 - Fixed: timestamp inside compressed file is not appropriate(SCGCQ02058485)
 - LSA capacity column sort not working in other Hardware Tab.(SCGCQ02058597)
 - Default Logical Drive name is showing as "VDName**" , while creating Logical drive through Simple Configuration(SCGCQ02062623)
 - WG: Element count not updated on selecting foreign drives and sorting Foreign drive list, it continues to show PD operations(SCGCQ02063630)
 - MRSA: LD Name discrepancy for 1 LD and 2 LDs without LD_Name during Array creation(SCGCQ02067043)
 - In presence of NVME drives, applying and Clearing filter and then sorting the drives results in incorrect PD list(SCGCQ02069473)
 -(SCGCQ02069524)
 -(SCGCQ02074686)
 - WG_7.10: Spacing alignments to be done in the VD setting page during the VD creation	(SCGCQ02076790)
 - WG_7.10: While consistency check is in progress on VD, if we click pause progress bar is misaligned(SCGCQ02076792)
 - Fixed: check in place to create nvmeOnly disk group during migration	(SCGCQ02076800)
 - WG: FDE foreign config after performing instant secure erase on one of the drive shows incomplete in LSA(SCGCQ02080536)
 - WG_7.10: Spell check and spacing issues in Latest LSA (007.010.003.000)(SCGCQ02081258)
 - "Drive Group list is empty" error message seen when multiple drives are assigned as DHSP to a VD, issue per(SCGCQ02081264)
 - Silent installation is NOT working on Ubuntu 16.04(SCGCQ02082129)
 - Download support Log not working.(SCGCQ02082514)
 - Aero (DBU PA3(SCGCQ02082524)
 - DG number displayed outside the box(SCGCQ02089434)
 - Aero DBU PA2(LSA	(SCGCQ02091088)
 - WG: selected element count shown wrong on selecting PD list(including mising(SCGCQ02095469)
 - Fixed: missing pd info was leading to population of wrong candidate pds(SCGCQ02095494)
 - WG: LSA Lists drives of a type even if less for a raid level creation if user selects raid level from compare select(SCGCQ02096215)
 - Fixed: Changed build files to build client for ESXi(SCGCQ02096396)
 - WG: LSA snapdump files generated are only of 32 kb even if the actual snapdump file size is much higher than that(SCGCQ02100467)
 - WG: Filter options does not list NVMe drives in PD list of controller console page(SCGCQ02107270)
 - WG: extracting snapdump file using 7zip, user is notified regarding header error in etty file, spacingissue of text in OFU(SCGCQ02108538)
 - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02108817)
 - Fix API changes done for NVMe readiness(SCGCQ02142981)
 - Add NVMe width comments to mr.h(SCGCQ02146846)
 - Fixed: changed the max drive value of R1 for cachecade drives(SCGCQ02169419)
 - LSA - AWB option is coming for CC VD with Rambler card while creating CC VD(SCGCQ02169687)
 - LSA Cache update for PD insert for it ctrls(SCGCQ02191080)
 - WG: LSA does not display the correct VD creation time in VD get URI response(SCGCQ01889478)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01902964)
 - LSA 7.9: Display error for "OS name" when expand/minimize is performed.(SCGCQ01904365)
 - Fixed: Configuration service changed to accomadate allomixinSSD bit(SCGCQ01925161)
 -(SCGCQ01927978)
 - LSA 7.9:Changing server parameter in Configfile.json file to 2 , scheduler does not kick inn and LSA crashes(SCGCQ01930410)
 - LSA 7.9 PA:failure messange with description success on enabling/disabling scsi unmap feature.(SCGCQ01936667)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01940852)
 - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01942985)
 - Fixed: Foreign drives are not considered as configured & which leads to a mismatch in JBODconversion count during VD creation(SCGCQ01943388)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01943617)
 - LSA 7.9: Mismatch in "Unconfigured drives and replace drive" count.(SCGCQ01944392)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01952143)
 - LSA 7.9:Unable to start instanst secure erase operation on multiple Pds when scheduler is on.(SCGCQ01955160)
 - WG: Issues pertaining to Settings page(SCGCQ01956683)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ01957078)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ01960300)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01962216)
 - LSA 7.9 alpha :The error code 69636 is seen without view more option when pause on CC operation is performed twice(SCGCQ01971576)
 - WG:LSA displays the snapdump count in hex value, GUI issues in snapdump pane(SCGCQ01973964)
 - MRSA event for Drive erase abort is coming blank in "View Event log" for event ID 421(SCGCQ01976894)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ01978171)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ01979083)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ01979598)
 - LSA : Port details are missing in drive removal/insert events.(SCGCQ01979793)
 - Fixed: missing Event description for new events was pausing LSA(SCGCQ01980570)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ01983080)
 - MRSA : Copyback progress details is not proper in BGI progress tab.(SCGCQ01996577)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02003711)
 - WG: GUI issues : Drive Security text on Hover, system messages clickable text, bell button notification(SCGCQ02006538)
 - “404 Not Found” seen on upgrading Snap4 GA to OEM Builds and later removing and installing new build(SCGCQ02016688)
 - LSA 7.10:Covert button of the Jbod table is activated and flickers when more than eligible count pds are selected.(SCGCQ02024507)
 - WG: No VD or PD details shown for progress operation in VMware(SCGCQ02028695)
 - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02031517)
 - WG : LSA Cache Offload Limit value change was not changing without manual refresh(SCGCQ02043843)
 - WG: LSA view event log list the Portmap as '0' instead of '08' for scsiType=0 (ie PDs)(SCGCQ02045715)
 - LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups.(SCGCQ02045735)
 - WG: LSA does not show the details of the current profile when there is only one profile supported(SCGCQ02045758)
 - WG: System LSA monitor event logs has junk characters(SCGCQ02049034)
 - WG: Path information for PD reset event is empty in event logs (event id : 268(SCGCQ02049577)
 - LSA: Domain login for administrator fails with "Error code:49 Invalid credentials".(SCGCQ02049807)
 - WG 7.10:if VD count is above limit and VD capacity is changed, LSA allows user to create VD which fails(SCGCQ02050533)
 - LSA Simple Configuration for R6 fails with error.(SCGCQ02053837)
 - LSA service crashing in ubuntu(SCGCQ02061370)
 - Linux Build is always picking old library(SCGCQ02061380)
 - Aero DBU PA2(LSA	(SCGCQ02065672)
 - Incorrect number of slots is displayed for UBM U.2X2 Vses Backplane in LSA.(SCGCQ02069871)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02070841)
 - Aero DBU PA2(LSA	(SCGCQ02074776)
 - WG_7.10:In the Error code:118 description, Spacing alignments to be done.(SCGCQ02076794)
 - WG_7.10: SAS address is shown for PCIe (NVME	(SCGCQ02076924)
 - Wide port info is not displayed for physical drive under connector name for Backplane attached drives.(SCGCQ02076933)
 - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02078435)
 - LSA: Read_only_access group users are given administrator privileges(SCGCQ02078614)
 - WG: User is notified to select the Drive group even if VD and PD tab of the DG is clicked(SCGCQ02080553)
 - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02081038)
 - During LSA upgrade some of the old build files are not removed in Ubuntu	(SCGCQ02082116)
 - WG 7.10: wrong health status of a gateway server seen when discovered from same gateway server.(SCGCQ02084545)
 - WG:LSA Direct agent or LWM installation from main package creates desktop shorcut in linux(SCGCQ02084636)
 - WG 7.10:Scheduler wrapper does not kick in for enable security operation(SCGCQ02085660)
 - Fixed: FDE and Opal mixing shouldn't be allowed(SCGCQ02086784)
 - Migration from R1 Vd(4 drives)(SCGCQ02087362)
 - Element action pane border incomplete during single PD selection, user name/password blue box alignment(SCGCQ02091191)
 - Issue pertaining to failure notification(SCGCQ02095408)
 - Fixed: FW upgrade issues with Aero FW files(SCGCQ02097971)
 - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02108807)
 - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119031)
 - Fixed: Cachecade VD creation diaglog doesnt populate Raid levels	(SCGCQ02142026)
 - "Remove drives" option should not come if user is doing RLM from R6 with 3 drives to R5(SCGCQ02184393)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01512320)
 - LSA needs to Handle when controller is in safe Mode	(SCGCQ01838234)
 - MRSA : MRSA shows the logout option in drop down menu .(SCGCQ01902913)
 - LSA 7.9: Unable to enter password while adding mail server authentication.(SCGCQ01933819)
 - LSA 7.9 :Status error description for schedular operation is not mapped to the proper device ID.(SCGCQ01940978)
 - WG: NO PD info is shown for foreign configuration(SCGCQ01942159)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ01942452)
 - WG:Remove icon for manually added server not shown in manage server page, Signin should be disabled when login in progress(SCGCQ01960469)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01961390)
 - LSA 7.9 alpha: Error code 69642 is seen when disable/enable unmap operation is performed on Unmap VD.(SCGCQ01963097)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01969806)
 - WG: All the events to Vmware are coming as information(SCGCQ01973905)
 - LSA 7.9: Incorrect critical message displayed for Offline PD.(SCGCQ01979150)
 - Fixed: Updated curl library for Linux OS	(SCGCQ01979794)
 - LSA 7.9: Re-scan button is disabled after GHS import.(SCGCQ01982953)
 - LSA 7.9:FDE HDDs are assigned as DHSP for an encrypted OPAL VD(SCGCQ01982973)
 - Status reports as failed although firmware is updated successfully(SCGCQ01983031)
 - MR 7.9 PA: LSA Win: 7.9_PA-007.009.007.000 Fails to display JBOD, StorCLI works fine(SCGCQ01994803)
 - LSA does not show failure or success notification when clear configuration is performed.(SCGCQ01996512)
 - WG: Instance Validation failed for Event history GET	(SCGCQ01998296)
 - LSA - Selected firmware version displayed as blank during update firmware(SCGCQ02034485)
 - LSA: Administrators User group is given Read only privileges after adding Users to Administrators group.(SCGCQ02048915)
 -(SCGCQ02048923)
 - Client changes for review-30 schema compliance(SCGCQ02062850)
 - Aero DBU PA2(LSA	(SCGCQ02065575)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070840)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02084515)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02094537)
 - GUI css issues with update firmware panel and snapdump actions(SCGCQ02094845)
 - Spacing issues seen while converting a drive from JBOD to UG	(SCGCQ02095422)
 - WG:Enclosure ID and Device ID display inconsistency in SS page and CC page, Configure options in SS page alignment issues(SCGCQ02095855)
 - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02103116)
 - Capacity sorting is not working in presence of TB drive in the PD list of VD creation.(SCGCQ02107449)
 - Snap dump trigger time format ends with Z character.(SCGCQ02184362)
 - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01880101)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ01880184)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ01888233)
 - LSA 7.8: Incorrect VD capacity size displayed during VD creation(SCGCQ01897176)
 - LSA 7.9: Mismatch in the alignment of server list.(SCGCQ01904368)
 - Update firmware version link not clickable in Server Landing Page(SCGCQ01905815)
 - After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01927915)
 - LSA Client: In Remote Discovery page, "servers" call is being made twice(SCGCQ01932106)
 - Incorrect tab listener in login page.(SCGCQ01932725)
 - LSA 7.9: "Personality management" page do not close automatically after launch of "Schedule consistency check" page.(SCGCQ01933812)
 - Fixed: clear and generate snap dump feature should not be displayed if snap dump is disabled(SCGCQ01936663)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01937263)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01951802)
 - WG:GUI issues:Controller health text,system message bar,download log, scheduler operation failure & JBOD to UG notifications(SCGCQ01968459)
 - Fixed: LSA 7.9:In presence of 32 GHSPs, advance configuration option is leading to configurable page on iMR card(SCGCQ01969524)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ01969611)
 - LSA_7.9: Status code and description are not clear during Unconfigured Bad to Unconfigured Good operation.(SCGCQ01972681)
 - WG: JBOD to UG conversion popup does not show error notification in case there is an OS drive, fails with 400ok though(SCGCQ01973688)
 - WG: Enabling and disabling the alarm multiple times shows error message without error code number(SCGCQ01973701)
 - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01974131)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ01993611)
 - LSA locate time inaccurate(SCGCQ02038270)
 - Aero DBU PA2(LSA	(SCGCQ02065617)
 - No response observed when tried to import Foreign LDs which results is reaching MAX LDs(SCGCQ02082982)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102427)
 - 7.10-LSA: Event ID 457 description ends junk character.(SCGCQ02184221)
 -	(SCGCQ01878801)
 - LSA 7.9: Incorrect value accepted during PD locate and wrong Icon displayed in IE when compared to Chrome.(SCGCQ01901766)
 - LSA server profile shows IT-IR storlib versions.	(SCGCQ01901771)
 - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ01901773)
 - LSA 7.9: Server search list no more displayed if the user press enter or move the cursor.(SCGCQ01905850)
 - PH10 PA - LSA - Logout option not presented when drop down arrow is clicked(SCGCQ01934763)
 - WG: Status code description is not proper(SCGCQ01942172)
 - LSA 7.9: After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01949787)
 - LSA 7.9 alpha:LSA Status code enhancements - Individual operations related issues(SCGCQ01961403)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ01968407)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ01973705)
 - LSA PR (SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562)
 - WG_7.10: Enclosure location shows blank for the NVME drives	(SCGCQ02076920)
 - LSA - AWB option is coming for CC VD with Rambler card when user try to modify VD properties if CC VD goes offline/degraded(SCGCQ02184389)
 - WG: Table formatting is not proper in controller console page(SCGCQ01875668)
 - Fixed: Adding more than 1 vd on a hole & adding more than 1 vds on existing DG fails in LSA(SCGCQ01940161)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01944435)
 - Fixed: Download DA/SA server report when downloaded remotely from Gateway(SCGCQ01969625)
 - MRSA: Enclosure count updated wrong in Server profile page(SCGCQ01976923)
 - For 7.10 LSA with max VD configuration, with foreign configuration present LSA unable to import or reject or proper message should displayed. Can you please look into this issue.(SCGCQ02184326)
 - LSA 7.9: Select and un-select button does not work after minimizing the tab(SCGCQ01978952)
 - Fixed: Blank page shown on trying to login 2nd time VMware using Manage server page(SCGCQ02035380)
 - LSA : Getting wrong data about max number of PD support for R6 while doing RLM(SCGCQ02184391)
 - SCGCQ01134787: GUI’s are required to be localized for the following languages: English, French, Italian, German, Spanish, and Japanese(SCGCQ01840448 port of SCGCQ01134787)
 - Security Standalone requirements for LSA Server code changes	(SCGCQ01854924 port of SCGCQ01399720)
 - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01857649 port of SCGCQ01598200)
 -	(SCGCQ01868298 port of SCGCQ01564366)
 - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01869716 port of SCGCQ01598139)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01962269 port of SCGCQ01898255)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802)
 - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963971 port of SCGCQ01512320)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390)
 - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01971208 port of SCGCQ01942985)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01972651 port of SCGCQ01966687)
 - Fixed: missing Event description for new events was pausing LSA(SCGCQ01991449 port of SCGCQ01980570)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02000919 port of SCGCQ01929667)
 - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02002118 port of SCGCQ01993697)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007219 port of SCGCQ01929667)
 - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02015378 port of SCGCQ01993697)
 - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure "(SCGCQ02016686 port of SCGCQ02009718)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02030825 port of SCGCQ02006229)
 - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02031020 port of SCGCQ02023407)
 - LSA Client : Trigger and Download Snap Dump from application	(SCGCQ02032043 port of SCGCQ01917087)
 - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02032206 port of SCGCQ02021372)
 - WG: No Action Successful notification shown on Drive erase(single Drive(SCGCQ02032617 port of SCGCQ01941129)
 -(SCGCQ02034407 port of SCGCQ02030621)
 -(SCGCQ02034409 port of SCGCQ02030621)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035246 port of SCGCQ02034466)
 - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02036726 port of SCGCQ02035226)
 - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929)
 - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02042291 port of SCGCQ02006229)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611)
 - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270)
 - LSA locate time inaccurate(SCGCQ02043619 port of SCGCQ02038270)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ02044809 port of SCGCQ01973705)
 - Issues wrt the linux installer script	(SCGCQ02044832 port of SCGCQ01879303)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078)
 - No help option available for Megacell option whenever it calls for “Needs Attention” in LSA(SCGCQ02050529 port of SCGCQ02022983)
 - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW	(SCGCQ02053882 port of SCGCQ02040516)
 - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ02055506 port of SCGCQ01901773)
 -(SCGCQ02055834 port of SCGCQ01878801)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055865 port of SCGCQ02035322)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02057603 port of SCGCQ02003711)
 - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ02064849 port of SCGCQ01984624)
 - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067442 port of SCGCQ02045048)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070858 port of SCGCQ02070840)
 - LSA: Read_only_access group users are given administrator privileges(SCGCQ02080158 port of SCGCQ02078614)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02087354 port of SCGCQ02070841)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02093538 port of SCGCQ02070841)
 - Fixed: Allowed Simple config parameters are not displayed(SCGCQ02094990 port of SCGCQ02076799)
 - LSA is not showing PD Connector information properly with passive backaplane	(SCGCQ02096769 port of SCGCQ02096766)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102495 port of SCGCQ02102427)
 - Application Crash when tried to create a LD with 15 character length	(SCGCQ02113222 port of SCGCQ02112041)
 - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119286 port of SCGCQ02119031)
 - Application Crash when tried to create an LD with 15 character length(SCGCQ02121748 port of SCGCQ02111930)
 - WG 7.11: Simple configuration fails when multiple vds are created.(SCGCQ02125582 port of SCGCQ02125538)
 - Configuration options is not getting updated when we change the personality(SCGCQ02154818 port of SCGCQ02124500)
 - Only 1 drive is displayed although more than 1 drive has opted for Dedicated drive(SCGCQ02154840 port of SCGCQ02113971)
 - Aero DBU PA5(LSA): Secure jbod option is not shown for the FDE capable jbod drive in LSA(SCGCQ02162725 port of SCGCQ02149233)
 - LSA service/Nginx service is stopping after few hours and WebGUI is not responding in RHEL 8.0 OS(SCGCQ02172192 port of SCGCQ02151342)
 - LSA Aero IT: LSA installation with "start from now" option is throwing error code:9098 in event logs.(SCGCQ02172199 port of SCGCQ02121896)
 - Event ID 610 and 611 are empty(SCGCQ02172244 port of SCGCQ02166100)
 - Generic LSA w/MRSA backend (Snap 3(SCGCQ01818695 port of SCGCQ01532391)
 - IML event customization (Mesa Verde(SCGCQ01837799 port of SCGCQ01625911)
 - Dual Firmware Image Support on Controller Flash for Recovery	(SCGCQ01847635 port of SCGCQ01320454)
 - LSA : Dqueue logs need to be fetched in smaller chunks by the applications(SCGCQ01860906 port of SCGCQ01571368)
 - SSD WEAR GAUGE Support(SCGCQ01891668 port of SCGCQ01890543)
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915862 port of SCGCQ01905192)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368)
 - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon	(SCGCQ01990298 port of SCGCQ01856350)
 - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01990346 port of SCGCQ01829895)
 - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon	(SCGCQ02001873 port of SCGCQ01856350)
 - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further	(SCGCQ02034499 port of SCGCQ02032031)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL)(SCGCQ02042097 port of SCGCQ01993099)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300)
 -(SCGCQ02043859 port of SCGCQ01927978)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055880 port of SCGCQ02035322)
 - Status reports as failed although firmware is updated successfully(SCGCQ02058472 port of SCGCQ01983031)
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ02081267 port of SCGCQ01838943)
 - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02084746 port of SCGCQ02078435)
 - NVMe Drive interface type should be shown as "NVMe" instead of "PCIe"(SCGCQ02100198 port of SCGCQ02096718)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427)
 - Fixed: Snap dump file(SCGCQ02105149 port of SCGCQ02080184)
 - WG 7.11:Jbod Locked foreign config details are empty under foriegn configuration operation.(SCGCQ02112529 port of SCGCQ02112203)
 - WG: LSA incorrectly notifies "Incomplete or Non-Importable foreign configuration found" instead of max supported configuratio(SCGCQ02162724 port of SCGCQ02149353)
 - WG: LSA shows the same connector for both backplane and enclosure in properties pane(SCGCQ02179358 port of SCGCQ02167855)
 - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01869701 port of SCGCQ01246226)
 - Support newly added Sanitize event for cache update.(SCGCQ01869717 port of SCGCQ01740786)
 - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01918643 port of SCGCQ01880101)
 -(SCGCQ01925516 port of SCGCQ01714322)
 - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074)
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume(SCGCQ01970440 port of SCGCQ01752969)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01974074 port of SCGCQ01971368)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466)
 - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067299 port of SCGCQ02044922)
 - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02082904 port of SCGCQ02081038)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427)
 - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02116793 port of SCGCQ02108807)
 - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02118270 port of SCGCQ02108817)
 -	(SCGCQ02154813 port of SCGCQ02142063)
 - Fixed: parity disk count was missing in algorithm to calculate minimum VD(SCGCQ02154869 port of SCGCQ02139246)
 - WG: LSA does not update on Clearing the config from server summary page in presence of degraded config(SCGCQ02160137 port of SCGCQ02154073)
 - LSA - upgrade installshield(SCGCQ02164387 port of SCGCQ02087375)
 - Download Server Report – change this to Download Support Log and Remove Download Diagnostics	(SCGCQ01824401 port of SCGCQ01388152)
 - LSA No Login (HPE Snap 3 SOW	(SCGCQ01840451 port of SCGCQ01512600)
 - Sanitize Support (HPE SNAP 3	(SCGCQ01857424 port of SCGCQ01564367)
 - IML event customization (Mesa Verde(SCGCQ01868281 port of SCGCQ01625911)
 - LSA is allowing to delete OS VD.	(SCGCQ01923557 port of SCGCQ01873420)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01942179 port of SCGCQ01937406)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive	(SCGCQ01962278 port of SCGCQ01952143)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967919 port of SCGCQ01918692)
 - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998976 port of SCGCQ01998305)
 - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007218 port of SCGCQ01929667)
 - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02053863 port of SCGCQ02035322)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02062148 port of SCGCQ02035158)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515)
 - Fixed: Calculation to get possible range for RLM	(SCGCQ02093240 port of SCGCQ02070841)
 - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02105326 port of SCGCQ02103116)
 - RHEL8- LSA reports warnings during Service restart after reboots, remote discovery page does not list any server other server(SCGCQ02159794 port of SCGCQ02144606)
 - : Support PCI Slot and Serial Number in(SCGCQ01822600 port of SCGCQ01351434)
 - MRSA:Default strip size should be 64KB for SSD(SCGCQ01825959 port of SCGCQ01406706)
 - Change the word data protection to Data Integrity Field(SCGCQ01839302 port of SCGCQ01827434)
 - Expander support for LSA(SCGCQ01839611 port of SCGCQ01372657)
 - (SCGCQ01681996: Copy back option should not prompt for already copyback progress PD.(SCGCQ01840438 port of SCGCQ01681996)
 - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01847392 port of SCGCQ01134783)
 -(SCGCQ01943786 port of SCGCQ01932181)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx	(SCGCQ02000918 port of SCGCQ01929667)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02012079 port of SCGCQ02000446)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427)
 - LSA is using old PDL for send Feedback option(SCGCQ02133579 port of SCGCQ02133392)
 - WG: Making an offline drive of a DG to online does not work in controller health pane, no POST call for same is initiated(SCGCQ02144596 port of SCGCQ02139321)
 - (SCGCQ01399721: Hercules :HPE: Security Standalone requirements for LSA Linux 32/64 bit Installer changes(SCGCQ01827380 port of SCGCQ01399721)
 - Support PCI Slot and Serial Number in Mesa Verde	(SCGCQ01839058 port of SCGCQ01349491)
 - Capacity Unit Changes for VD in LSA Client from GB to GIB(SCGCQ01859426 port of SCGCQ01708968)
 -	(SCGCQ01864209 port of SCGCQ01763927)
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904366 port of SCGCQ01901758)
 - IML event customization (Mesa Verde(SCGCQ01837623 port of SCGCQ01601601)
 - Megacell Status Support (SNAP3(SCGCQ01868328 port of SCGCQ01566234)
 -	(SCGCQ01869156 port of SCGCQ01320455) -
 - WG 7.11:Enable scsi unmap checkbox at advance config page is grayed out when enable/disable operation is performed.(SCGCQ02154812 port of SCGCQ02118865)
 - Security Standalone requirements for LSA Server code changes(SCGCQ01854929 port of SCGCQ01399722)
 - Expander support for LSA	(SCGCQ01855600 port of SCGCQ01376077)
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01869616 port of SCGCQ01849749)
 - Capacity Unit Changes for VD in LSA Server(SCGCQ01869745 port of SCGCQ01708881)
	
EnhancementRequests (35)
 - Enhance Status Code and Status description(SCGCQ01825960)
 - LSA Internal Status code and Description(SCGCQ01850884)
 -(SCGCQ01949651)
 - Branding tool and Health (OS eventing(SCGCQ01960398)
 - Ubuntu LSA support(SCGCQ02042072)
 - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048)
 - Branding tool and Health (OS eventing(SCGCQ02045972)
 - API changes for NVMe speed and width changes(SCGCQ02053667)
 - API changes for linkconfig interface	(SCGCQ02053671)
 - Change the parent directory name to "HPEMRSA" in the windows(SCGCQ02055912)
 - Implement Changes for LSA Light weight agent On ESXi 64 bit Platform(SCGCQ02066385)
 - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252)
 - API changes for a better presentation of Atlas to tools(SCGCQ02149380)
 - Snap Dump ClearAll Method logging event(SCGCQ02157359)
 -(SCGCQ02162699)
 - Create an event for DDF config clear failed event.(SCGCQ02173513)
 - WG: LSA "Feedback" UI enhancements(SCGCQ01401503)
 - LSA Client : Trigger and Download Snap Dump from application(SCGCQ01917087)
 - Implemented: Allow user to generate snap-dump in firmware and download it(SCGCQ01917294)
 - Client: Ubuntu LSA support(SCGCQ02042121)
 - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02044922)
 - 64 Bit SLIR3 library to Support for VMWARE ESXi 6.7+	(SCGCQ02048704)
 - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334)
 - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048)
 - Add new topology device type for Atlas switch(SCGCQ02150637)
 - LSA need to show complete Serial Number and Model Name for NVMe drives(SCGCQ01920105)
 - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ01984624)
 - SSD WEAR GAUGE Support(SCGCQ01890543)
 - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ01929667)
 - 64 Bit SLIT library Support for VMWARE ESXi 6.7+	(SCGCQ02019271)
 - LSA: SSD WEAR GAUGE Support(SCGCQ01890612)
 - MRSA One Click Support Client support(SCGCQ01949650)
 - LSA Server: Scheduler changes to fit with latest LSA status code(SCGCQ01857843)
 - Enhance Status Code and Status description(SCGCQ01868342)
 - LSA Server: Aero FW simplification - Changes for disable least latency mode(SCGCQ01944689)

005.047.000.000 - Moderate Impact
---------------

Defects:
 -WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01680714)
 -Fixed: nvme is allowed to mix with sas /sata.(SCGCQ01762948)
 -WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile.(SCGCQ01747490)
 -WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline(SCGCQ01752969)
 -WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod.(SCGCQ01763742)
 -WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection).(SCGCQ01764794)
 -WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01737550)
 -LSA locate time inaccurate.(SCGCQ02038270)
 -LSA PR SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562)
 -LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups..(SCGCQ02045735)
 -LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab.(SCGCQ02078435)
 -LSA: Read_only_access group users are given administrator privileges.(SCGCQ02078614)
 -RWC3 Windows Readme contains IR3 controllers under supported controllers list.(SCGCQ02081038)
 -Fixed: R00 max pd limit is changed to be aligned with fw requirement.(SCGCQ02108807)
 -LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1.(SCGCQ02108817)
 -LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info..(SCGCQ02119031)
 - LSA installation failed on SLES15.(SCGCQ01784699 port of SCGCQ01760620)
 - LSA needs proper message for max config import.(SCGCQ01789100 port of SCGCQ01763411)
 - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01789156 port of SCGCQ01731931)
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716625 port of SCGCQ01716622)
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup.(SCGCQ01810649 port of SCGCQ01803341)
 - MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813086 port of SCGCQ01813078)
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01816649 port of SCGCQ01686080)
 - MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01816428 port of SCGCQ01641760)
 - LSA needs proper message for max config import.(SCGCQ01813925 port of SCGCQ01764977)
 - C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01828830 port of SCGCQ01321211)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events.(SCGCQ01826237 port of SCGCQ01761830)
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828)
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01851980 port of SCGCQ01851906)
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA.(SCGCQ01851919 port of SCGCQ01841280)
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681)
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS..(SCGCQ01880123 port of SCGCQ01876091)
 - handling the session management.(SCGCQ01892868 port of SCGCQ01829897)
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01891168 port of SCGCQ01889547)
 - Handling the set text mechanism in client.(SCGCQ01886532 port of SCGCQ01850387)
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01897181 port of SCGCQ01841473)
 - Fixed: Crash when pressing back button after logout.(SCGCQ01892905 port of SCGCQ01865309)
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01897266 port of SCGCQ01818960)
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943)
 - fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01901774 port of SCGCQ01866289)
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01898263 port of SCGCQ01802344)
 - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01901754 port of SCGCQ01827404)
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01897144 port of SCGCQ01817275)
 - Update the Windows Server 2019 OS name in LSA.(SCGCQ01897178 port of SCGCQ01866322)
 - Remove un printable characters from LSA log.(SCGCQ01901769 port of SCGCQ01901760)
 - Server: LSA GUI Not Updating Security Key Info.(SCGCQ01897099 port of SCGCQ01761801)
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle.(SCGCQ01915861 port of SCGCQ01905192)
 - [CISCO]LSA shows previously set security key (M3g@raid) during importing secured foreign config JBOD (TCG Enterprise SED).(SCGCQ01921581 port of SCGCQ01878346)
 - LSA fails to start initialization on EPD if it has DDF.(SCGCQ01921583 port of SCGCQ01849522)
 - (SCGCQ01921684 port of SCGCQ01841361)
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event.(SCGCQ01921836 port of SCGCQ01876230)
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives..(SCGCQ01904075 port of SCGCQ01893304)
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade..(SCGCQ01904345 port of SCGCQ01901758)
 - .(SCGCQ01920699 port of SCGCQ01808698)
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01921839 port of SCGCQ01829669)
 - (SCGCQ01921842 port of SCGCQ01803373SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS)
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249)
 - .(SCGCQ01920924 port of SCGCQ01818618)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01921819 port of SCGCQ01856350)
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,.(SCGCQ01915812 port of SCGCQ01906914)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895)
 - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01829895)
 - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01865420)
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350)
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives DESCRIPTION OF ISSUE(SCGCQ01921580 port of SCGCQ01823858)
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445)
 -WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674 )
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command.(SCGCQ01930623 port of SCGCQ01926876)
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01961510 port of SCGCQ01889547)
 - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01980553 port of SCGCQ01979137)
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768)
 - Optimize the operation areas of UI to add “on demand” call and increase the performance(SCGCQ01792860 port of SCGCQ01746630)
 - Add sorter on individual panel's header(SCGCQ01792967 port of SCGCQ01614993)
 - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793020 port of SCGCQ01761197)
 - LSA Server: Enhance view server profile(SCGCQ01793119 port of SCGCQ01613889)
 - Add a way to move from Server / Controller dashboard to Login / Remote Server Discovery Page.(SCGCQ01793314 port of SCGCQ01760616)
 - LSA Client : GUI User Interface to display snap dump details and download snap dump.(SCGCQ01788693 port of SCGCQ01788622)
 -GUI Performance improvement by reducing the GUI binary size.(SCGCQ01791174 port of SCGCQ01484572)
 - WG: Clicking on help links anywhere in LSA page for VMware leads to "404-not found" page.(SCGCQ01791205 port of SCGCQ01594101)
 - LSA Server: Client Logging(SCGCQ01793221 port of SCGCQ01745790)
 - Enhance Action menu of individual and group element(SCGCQ01793250 port of SCGCQ01606850)-
 - Add Select All / Un-Select All option to dashboard tables.(SCGCQ01793004 port of SCGCQ01580899)
 - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793081 port of SCGCQ01761224)
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01798297 port of SCGCQ01745770)
 - Use scheduler call for heavy operations Part 2.(SCGCQ01792861 port of SCGCQ01746649)
 - SCGCQ01583133: Inconsistency of login dialog box in Manageserver page and Remote discovery page(SCGCQ01793098 port of SCGCQ01583133)
 - Fixed: LSA allows the user to attempt a 3 drive RAID6 VD creation (via RAID60).(SCGCQ01798511 port of SCGCQ01687523)
 - SCGCQ01631835: WG: error log and Access log consume entire OS file system space (6.3 GB and 2.6 GB respectively)(SCGCQ01798635 port of SCGCQ01631835)
 - LSA: SnapDump Implementation(SCGCQ01788680 port of SCGCQ01786658)
 - Enhance Properties panel of Individual elements.(SCGCQ01792093 port of SCGCQ01613898)
 - Handle Progress events without initiating further api call from Client.(SCGCQ01792974 port of SCGCQ01761196)
 - LSA Client Logging.(SCGCQ01792995 port of SCGCQ01752841)
 - LSA Client: Enhance view server profile(SCGCQ01793196 port of SCGCQ01613529)
 - LSA: SnapDump Implementation.(SCGCQ01793838 port of SCGCQ01786658)
 - (SCGCQ01798366 port of SCGCQ01628367)
 - Implemented: LSA: Disable Cached IO option during VD creation(SCGCQ01798387 port of SCGCQ01697006)
 - LSA Server: Optimize the operation areas of UI to add “on demand” call and increase the performance.(SCGCQ01793279 port of SCGCQ01745789)
 - Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01794950 port of SCGCQ01793057)
 - SCGCQ01595244: WG: issues pertaining to lsa logs file generation in VMware.(SCGCQ01798451 port of SCGCQ01595244)
 - Adding filters to the PD and VD table.(SCGCQ01625154 port of SCGCQ01614984)
  - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01798299 port of SCGCQ01731931)
 - WG: Enclosure position is not shown in Progress bar PD details for any enclosure above position index=1 as well as event logs.(SCGCQ01801670 port of SCGCQ01794642)
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives).(SCGCQ01818637 port of SCGCQ01803743)
  - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01818638 port of SCGCQ01809413)
 - Adding filters to the PD and VD table.(SCGCQ01807941 port of SCGCQ01614984)
 - Implementation of LW Agent Related Back-end changes.(SCGCQ01801403 port of SCGCQ01591705)
 - Add SCSI Unmap property at PD level.(SCGCQ01813071 port of SCGCQ01732785)
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01818554 por of SCGCQ01680714)
 - WG: Duplicate PD entires of replace Drive listed in PD list of controller console page on sorting the PD list more than twice.(SCGCQ01803785 port of SCGCQ01794631)
 - WG: View more properties pane is overlapped by the progress bar if the progress info is in expanded state.(SCGCQ01803986 port of SCGCQ01763142)
- MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813180 port of SCGCQ01813078)
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG.(SCGCQ01818631 port of SCGCQ01803722)
 - Unable to import foreign secured VDs with different security key.(SCGCQ01818678 port of SCGCQ01670139)
 - LSA needs proper message for max config import.(SCGCQ01813926 port of SCGCQ01764977)
 - MR7.6: LSA crashed with a mouse click on VD.( SCGCQ01819577 port of SCGCQ01641760)
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01822126 port of SCGCQ01686080)
 -.(SCGCQ01824435 port of SCGCQ01317424)
 -.( SCGCQ01827729 port of SCGCQ01808698)
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01837518 port of SCGCQ01802344)
 - handling the session management.(SCGCQ01841323 port of SCGCQ01829897)
 - LSA PD slot numbering doesn't not display as ascending order by default(SCGCQ01415337 port of SCGCQ01406115)
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config(SCGCQ01838336 port of SCGCQ01818953)
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config(SCGCQ01838335 port of SCGCQ01817275)
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01837786 port of SCGCQ01745768)
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01838449 port of SCGCQ01818960)
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01839325 port of SCGCQ01737550)
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01845011 port of SCGCQ01841473)
 - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons(SCGCQ01848661 port of SCGCQ01840475)
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01847352 port of SCGCQ01763742)
 - LSA Client: Improving visible / working area on elements tab(SCGCQ01839616 port of SCGCQ01837412)
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01879301 port of SCGCQ01874487)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830499 port of SCGCQ01761830)
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830498 port of SCGCQ01761830)
 - Drive status not displayed in Other Hardware tab(SCGCQ01855592 port of SCGCQ01849636)
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01874490 port of SCGCQ01866289)
 - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons.(SCGCQ01864285 port of SCGCQ01840475)
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01852072 port of SCGCQ01851906)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS..(SCGCQ01869568 port of SCGCQ01829895)
 - LSA Not allowing to clear/Import foreign configuration..(SCGCQ01860931 port of SCGCQ01849749)
 - LSA Client : 7.8 Coverity defects fix.(SCGCQ01865174 port of SCGCQ01837314)
 - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01855872 port of SCGCQ01827404)
 - LSA is allowing to delete OS VD.(SCGCQ01883000 port of SCGCQ01873420)
 - Implementation of LW Agent Related Back-end changes.(SCGCQ01801314 port of SCGCQ01591705)
 - LSA is allowing to delete OS VD.(SCGCQ01906734 port of SCGCQ01873420)
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01905909 port of SCGCQ01886563)
 - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.( SCGCQ01906795 port of SCGCQ01893511)
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01893311 port of SCGCQ01761269)
 -LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01890993 port of SCGCQ01829669)
 -.(SCGCQ01914269 port of SCGCQ01906844)
 - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.(SCGCQ01914265 port of SCGCQ01893511)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921950 port of SCGCQ01856350)
 - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab.(SCGCQ01962269 port of SCGCQ01898255)
 - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852)
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406)
 - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964)
 - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802)
 - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435)
 - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390)
 - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216)
 - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775)
 - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617)
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692)
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368)
 - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234)
 - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263)
 - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074)
 - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275)
 - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01962278 port of SCGCQ01952143)
 - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD.(SCGCQ01972651 port of SCGCQ01966687)
 - SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA) Uninstall Error: "Option “-x” is deprecated" w/ Linux RHEL 7.6.(SCGCQ02002118 port of SCGCQ01993697)
 - (CSETActivity) - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state.(SCGCQ02032206 port of SCGCQ02021372)
 -.(SCGCQ02034407 port of SCGCQ02030621)
 - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270)
 - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184)
 - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452)
 - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress.(SCGCQ02044809 port of SCGCQ01973705)
 - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171)
 - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929)
 - Memory Leak issues LSA Build (7.009.007.00)(SCGCQ02042291 port of SCGCQ02006229)
 - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080)
 - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611)
 - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007)
 - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083)
 - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781)
 - Issues wrt the linux installer script(SCGCQ02044832 port of SCGCQ01879303)
 - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078)
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ02001873 port of SCGCQ01856350)
 - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926)
 - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386)
 - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233)
 - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598)
 - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300)
 -(SCGCQ02043859 port of SCGCQ01927978)
 - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407)
 - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452)
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895)
 - SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711)
 - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806)
 - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611)
 - LSA Client : Trigger and Download Snap Dump from application(SCGCQ02032043 port of SCGCQ01917087)
 - WG: No Action Successful notification shown on Drive erase(single Drive), Application Version shown as undefined for VMware(SCGCQ02032617 port of SCGCQ01941129)
 - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245)
 - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL) when Drive security is enabled.(SCGCQ02042097 port of SCGCQ01993099)
 - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446)
 - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739)
 - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466)
 - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02053863 port of SCGCQ02035322)
 - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02070858 port of SCGCQ02070840)
 - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322)
 - Fixed: Calculation to get possible range for RLM(SCGCQ02093538 port of SCGCQ02070841)
 - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515)
 - Fixed: Calculation to get possible range for RLM(SCGCQ02093240 port of SCGCQ02070841)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427)
 - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427)
 - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537)
 
EnhancementRequest:
 -Update candidate drive list for VD creation when UNMAP/FDE etc Exist.(SCGCQ01879211)
 -Aero None-Mode implementation.(SCGCQ01871350)
 -Add CTRL_SB_SOFT_SECURE_MODE event to indicate soft secure mode.(SCGCQ01965721)
 -LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog.(SCGCQ02044922)
 -LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048)
 -LSA Standalone - enhanced authentication/authorization (Windows).(SCGCQ01984624)
 - Increase in MR_PD_INFO.name length to 32 characters.(SCGCQ02079068)
 -Better error message for certain unmap operations.(SCGCQ02111563)
 - MR Windows IOCTL Error codes to Application added to MR API.(SCGCQ02103183)
 - API change to support NVMe Passthrough over OOB.(SCGCQ02035295)
 - API change to support new DCMD for consolidated device list.(SCGCQ02037158)
 - Customer needs to generate and extract the On-demand based debug data both for MR and iMR..(SCGCQ02000566)
 - Modification in MR_SNAPDUMP_TRIGGER_TYPE enum value.(SCGCQ02030653)
 - Reword event log messages as it creates unnecessary panic..(SCGCQ02013675)
 - Add New Generic OOB API To Read ROC Temp, Drive Temp, Drive Type, Drive Protocol and status through OOB BMC.(SCGCQ01940661)
 - Add a bit for atomic descriptor capable.(SCGCQ01965047)
 - Additional details about spare.(SCGCQ02033538)
 - API changes for Lane Margining.(SCGCQ01921241)
 - Introduced new controller bit.(SCGCQ01985474)
 - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change.(SCGCQ02103973)
 - Driver parameter bit for support of tool box cmd.(SCGCQ02002119)
 - API change to support new DCMD for consolidated device list.(SCGCQ02016723)
 - .(SCGCQ01740789)
 
 
004.189.000.000 - Moderate Impact
---------------

 -(SCGCQ01351380) 
 - WG: Physical Drives tab should be aligned in center for Advanced Configuration.(SCGCQ01440777) 
 - Fixed: settings in configuration service API is inconsistent with other applciations(SCGCQ01518134) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01534444) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01539326) 
 - LSA Client 7.6: SPAN drives order is not maintained(SCGCQ01539355) 
 - Client: LSA should handle the not empty check for enclousre field for the physicalDevices response(SCGCQ01555968) 
 - IT-FURY-PH16:LSA-4.126.0.0-Fully Populated Enclosure S/N is "NA" and shown correctly after few drive removals.(SCGCQ01563352) 
 - SCGCQ01565134: IT-Ventura-PH7:LSA-4.126.0.0- FW update fails with error "File size Exceeds 16MB".(SCGCQ01565134) 
 - WG : Server detail is getting populated twice when user is using local IP (127.0.0.1(SCGCQ01565327) 
 - WG: During VD Creation on Simple Configuration, Clicking more than Once on the Finish Button is giving a Wrong Message.(SCGCQ01569262) 
 - WG: Copyright info is shown as 2017 instead of 2018(SCGCQ01571088) 
 - WG:Pop Up scroll missing in case there are more number of VDs to add while setting patrol read properties & Schedule CC(SCGCQ01571089) 
 - WG: User is notified to that multiselect PD/VD displays the properties but it is not supported(SCGCQ01571095) 
 - IT-FURY-PH16:LSA-SATA NCQ bit is always shown as disabled(SCGCQ01571261) 
 - LSA is not responding if online state is changed to offline(SCGCQ01571453) 
 - SCGCQ01571863: WG: LSA installation/uninstallation on linux does not notify the user on success or failure(SCGCQ01571863) 
 - Fixed: Windows OS details were reported as VMware details in Manual Search(SCGCQ01571874) 
 - WG: LSA wrapper indicates the progress of operations appears to be clickable while there is nothing user can select from list(SCGCQ01573087) 
 - SCGCQ01575706: WG:LSA installation exits on invalid option for selecting range of LSA events, it asks for retry with options listed again(SCGCQ01575706) 
 - SCGCQ01575999: FURY-PH16:LSA-Model Number is getting truncated for ST3000DM001,Hitachi HDS723020BLA642 models.(SCGCQ01575999) 
 - WG: the string 'status' is displayed multiple times after searching the server for manual addition(SCGCQ01577707) 
 - WG: LSA allows to replace HDD missing drive with SSD UG drive, fails with Partial Success.0 Successful;1 Failed notification(SCGCQ01577769) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01578248) 
 - LSA Server: Removal of Additional Carriage Returns and Line feeds in tty log file(SCGCQ01579290) 
 - WG: Error message on a failed VD creation is displayed outside the allocated space(SCGCQ01586721) 
 - SCGCQ01588880:(SCGCQ01588880) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01590450) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01595641) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01601386) 
 -(SCGCQ01628332) 
 - fixed: Advanced Configuration is grayed out when there are 2 jbods available in the system.(SCGCQ01631267) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01669558) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01675460) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01681070) 
 - WG: LSA 7.7 PA2 Not able to create RAID 00 VDs on iMR Ventura controller(SCGCQ01683638) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01683938) 
 - During migration from r0(opal drives and non-secured) to r1, Add Pd list does not list the available drives (Greater/same si(SCGCQ01687072) 
 - WG: Issues pertaining to searching of the server : manual discovery in list view & GUI issues in the manual discovery panel(SCGCQ01687117) 
 - MR7.7_LSA: Unable to convert JBOD to UG when filesystem is present(SCGCQ01697980) 
 - LSA Linux doesn't have latest storelib(SCGCQ01713580) 
 - WG MR 7.7 PA2: LSA allows to add FDE and OPAL drives to create Encrypted volume(SCGCQ01721222) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01761801) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01761830) 
 - Fixed: nvme is allowed to mix with sas /sata(SCGCQ01762948) 
 - SCGCQ01763132: LSA: Alert Configuration response contains unsupported character(SCGCQ01763132) 
 - Foreign Config preview should show the VD details also(SCGCQ01788639) 
 - LSA Opal: RLM mixing for Opal SSC and Enterprise shouldn't be allowed when enableFDETypeMix=0(SCGCQ01790063) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) 
 - compilation error in server(SCGCQ01817434) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01841473) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856350) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - WG: LSA shows incorrect popups while making the drive from offline to online & vice versa(SCGCQ01922610) 
 - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01937406) 
 - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971368) 
 -(SCGCQ01542415) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01552654) 
 - Correcting the library version display, ini file contents and also the readme files contents.(SCGCQ01561849) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01564526) 
 - SWR: Device ID is not displayed in LSA.(SCGCQ01564621) 
 - MR/IR: Controller Device ID value mismatch in LSA(SCGCQ01564622) 
 - WG:LSA and web server port have references of SLIM and nignx in notification if invalid ports are given during LSA installatn(SCGCQ01571099) 
 - WG: Issues pertaining to replace drive confirmation popup(SCGCQ01573101) 
 - Security related information should not be displayed in IR/IT for LSA(SCGCQ01577891) 
 - LSA allows user to assgin a 512 B drive as replacement to 4k missing drive in a DG(SCGCQ01591175) 
 - SCGCQ01593058: Add non printable character support for sata pd product id display(SCGCQ01593058) 
 - Add a provision to indicate VMware/NonVmware server in Manual Discovery Panel(SCGCQ01600706) 
 - LSA WG FURY IT: UEFI image download is failing in LSA(SCGCQ01616545) 
 - LSA 7.6 Server: LSA is showing the option for PD:"Undo Prepare For Removal", when the DG is in TR state(SCGCQ01618243) 
 - Not able to create secure VD with latest MR 7.7 LSA 177.000.000-SCGCQ01664972 but OK with previous version(SCGCQ01665121) 
 - Error observed while adding Windows gateway server in through manual discovery(SCGCQ01675601) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01677101) 
 - LSA MR7.7 PA2: Previously cleared configuration is seen in presence of OPAL foreign drive in Jbod Mode.(SCGCQ01685488) 
 - WG MR7.7 PA2:Once the 69639 error code is seen in LSA, performing every valid operation fails until manual refresh is perfo(SCGCQ01686013) 
 - WG MR 7.7:There is no import option for GHS Foreign device in LSA(SCGCQ01698105) 
 - Fixed: LSA handle count increase was observed(SCGCQ01713154) 
 - Add physical Drives page is not consistent across (Advanced Configuration and Modify drive Group(SCGCQ01716606) 
 - LSA: Handle Opal drive scenario for Hotspare and replace drive(SCGCQ01719043) 
 - LSA client: Add support to show incompatible profiles details(SCGCQ01727270) 
 - Add SCSI Unmap property at PD level(SCGCQ01732785) 
 - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01745770) 
 - WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile(SCGCQ01747490) 
 - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline.(SCGCQ01752969) 
 - [CISCO][TR]"Clear Transport Ready" option on rebuild LD should be removed or greyed out in LSA(SCGCQ01753229) 
 - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01761269) 
 - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01763742) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813078) 
 - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01833469) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01838943) 
 - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01886563) 
 - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01918692) 
 -(SCGCQ01534450) 
 - LSA needs to change "Error code" : 86017, Description:Operation failed because of a resource reservation error" to proper mes(SCGCQ01556013) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01581943) 
 - SCGCQ01582139: MR7.6_LSA: Enclosure ID and Device ID is shown blank in LSA event logs(SCGCQ01582139) 
 - WG: LSA Page auto scrolls down with scheduler wrapper going out of focus. LSA page would now be only half transparent(SCGCQ01586697) 
 - PH7 LSA WG Ventura: Sorting the drives on the basis of Device ID is not working fine(SCGCQ01587630) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01593855) 
 - WG: Instance validation failed for controller GET(SCGCQ01601458) 
 - WG: Minor text changes to be made in user information when no rows are selected in PD tab / DG tab / other hardware tab(SCGCQ01601656) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01615856) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01638193) 
 - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress(SCGCQ01680714) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01685449) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01686024) 
 - Instant Secure Erase does not work in VMware when schedule is enabled(SCGCQ01686028) 
 - MR7.7_LSA: Error code:0 is observed when driver security is changed in LSA(SCGCQ01686050) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716622) 
 - fixed: max pd is a bigger number than the actual allowed max pd per raid level(SCGCQ01746200) 
 - WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection(SCGCQ01764794) 
 - WG: gateway system is not discovering systems with different web port number in remote discovery page.(SCGCQ01788630) 
 - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives)(SCGCQ01803743) 
 - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01809413) 
 - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) 
 - fixed: Info "1920 more drives can be added" need to change in LSA(SCGCQ01827401) 
 - The display wrong location in page(SCGCQ01836732) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01355833) 
 - WG: Changing the drive security key with invalid authentication key results in notification that is not in format(SCGCQ01573090) 
 - WG: Raid 00 DG having missing drives Span list dissapears when user tries to sort the drives based on capacity(SCGCQ01577833) 
 - MR 7.7: LSA did not allow to pick all SED/FDE but OK to pick one by one when create secure VD(SCGCQ01629062) 
 - SCGCQ01718994: LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01718994) 
 - When there is pending personality, do not allow behavior Mode change, GUI refresh issue(SCGCQ01731312) 
 - Assign DHS is not showing any message in failure case(SCGCQ01732485) 
 - To enable the Alarm user has to click on the bottom of checkbox(SCGCQ01740783) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01818960) 
 - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives(SCGCQ01850008) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) 
 - LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01533554) 
 - WG: change Behavior Mode From JBOD to None is Not Working until closing the window(SCGCQ01635541) 
 - WG MR7.7PA2:In Jbod mode after first reboot and after converting Jbod to UG, advance configuraton leads to Jbod table.(SCGCQ01683001) 
 - MR 7.7 PA2: LSA does not refresh DG icon when PDs are made offline to online and visa versa.(SCGCQ01686029) 
 - WG MR 7.7 PA2:Encrypted Opal drive VD supports the Opal drive replacement with FDE drive(SCGCQ01697265) 
 - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button(SCGCQ01737550) 
 - MR 7.7 alpha: LSA displays raid 1 as raid 1E when created using 4 drives.(SCGCQ01764771) 
 - SCGCQ01564386: IT-FURY-PH16:Drives are not listed under Enclosures ( "0" drives) under other Hardware if connected in Multipath.(SCGCQ01564386) 
 - Coverity Defect fix in 7.7 Stream(SCGCQ01682365) 
 - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01714415) 
 - Client changes for defect SCGCQ01629703(SCGCQ01714659) 
 - MR7.7_LSA: After disabling PR, PR properties shows next scheduled time(SCGCQ01718119) 
 - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG(SCGCQ01803722) 
 - LSA is not locating all drives correctly(SCGCQ01924674) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01515496) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01563343) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01629574) 
 - Fixed: Show Advanced Config menu only if Unconfigured UG is present(SCGCQ01629703) 
 - WG: Readme shows wrong Version of LSA in html\files\LSA_ReadMe\LSA_Readme(SCGCQ01822525) 
 - SCGCQ01822561: WG: Changed LSA port is not listed after Direct agent installation on Rhel(SCGCQ01822561) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01866289) 
 - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01564627 port of SCGCQ01542412) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01564633 port of SCGCQ01562368) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01564739 port of SCGCQ01545262) 
 - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01564943 port of SCGCQ01534444) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565025 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01565116 port of SCGCQ01555955) 
 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01566088 port of SCGCQ01562368) 
 - WG: No success or failure notification is shown on enabling the JBOD drive security(SCGCQ01566435 port of SCGCQ01511274) 
 - SCGCQ01545384: Installation of LSA with LWM option is showing installation_type = 0, in the LSA.conf file(SCGCQ01567110 port of SCGCQ01545384) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569267 port of SCGCQ01504080) 
 - Making rebuild drive offline lsa gets 404.(SCGCQ01569465 port of SCGCQ01542412) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01569474 port of SCGCQ01539349) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01569949 port of SCGCQ01563340) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01570203 port of SCGCQ01550970) 
 - Enclosure's physicaldevices URI getting failed with 405 error(SCGCQ01589492 port of SCGCQ01523122) 
 - Label of the user menu drop down should change reinforcing that selection worked.(SCGCQ01597876 port of SCGCQ01493942) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01599402 port of SCGCQ01563340) 
 - Version changes for LSA 4.129 common project(SCGCQ01601148 port of SCGCQ01601146) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601603 port of SCGCQ01598515) 
 - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01604992 port of SCGCQ01564526) 
 - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01605344 port of SCGCQ01581943) 
 - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01609343 port of SCGCQ01578248) 
 - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01614982 port of SCGCQ01355833) 
 - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01616555 port of SCGCQ01595641) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01617930 port of SCGCQ01401460) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01628354 port of SCGCQ01504080) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01634072 port of SCGCQ01473733) 
 - WG: few of the alert params have the missing controller ID tag for the events(SCGCQ01635756 port of SCGCQ01625923) 
 - LSAServer: Use scheduler call for heavy operations for performance improvement - PD Operations(SCGCQ01635765 port of SCGCQ01514283) 
 - WG: though the hotspare button will be disabled after adding VD for a Raid 1 DG, the hand cursor button appears(SCGCQ01635778 port of SCGCQ01626738) 
 -(SCGCQ01639457 port of SCGCQ01599526) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01685343 port of SCGCQ01641760) 
 - Raid 1 Volume creation using 4 drives is displayed as Raid 1E(SCGCQ01686231 port of SCGCQ01686106) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687172 port of SCGCQ01686080) 
 - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01697468 port of SCGCQ01683941) 
 - LSA fails to flash GPMR2 package 50.1.0-1048 on top of MR 7.6 package 50.6.0-1255 on first try-it is successful on 2nd try(SCGCQ01697485 port of SCGCQ01680521) 
 - LSA not showing the proper time stamp in the schedule PR page(SCGCQ01698028 port of SCGCQ01677008) 
 - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01719179 port of SCGCQ01515496) 
 -(SCGCQ01733306 port of SCGCQ01721811) 
 - Fixed: LSA handle count increase was observed(SCGCQ01742153 port of SCGCQ01713154) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01747012 port of SCGCQ01745768) 
 - Server schema validation is failing(SCGCQ01764913 port of SCGCQ01619401) 
 - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01764928 port of SCGCQ01638193) 
 - LSA installation failed on SLES15(SCGCQ01784699 port of SCGCQ01760620) 
 - LSA needs proper message for max config import(SCGCQ01789100 port of SCGCQ01763411) 
 - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) 
 - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup(SCGCQ01810649 port of SCGCQ01803341) 
 - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813086 port of SCGCQ01813078) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01816649 port of SCGCQ01686080) 
 - C480-M5: LSA downloaded event log needs better decoding(SCGCQ01828830 port of SCGCQ01321211) 
 - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) 
 - Tape drive state is blank when connected with 9400-8E card from LSA drives tab(SCGCQ01851980 port of SCGCQ01851906) 
 - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) 
 - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01897266 port of SCGCQ01818960) 
 - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) 
 - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01901767 port of SCGCQ01833469) 
 - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01901774 port of SCGCQ01866289) 
 - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915861 port of SCGCQ01905192) 
 - [CISCO]LSA shows previously set security key (M3g@raid(SCGCQ01921581 port of SCGCQ01878346) 
 - LSA fails to start initialization on EPD if it has DDF(SCGCQ01921583 port of SCGCQ01849522) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) 
 -(SCGCQ01921684 port of SCGCQ01841361) 
 - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event(SCGCQ01921836 port of SCGCQ01876230) 
 - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01538488 port of SCGCQ01473733) 
 -(SCGCQ01564591 port of SCGCQ01515389) 
 - WG: System display uniformity is not there in GUI (Remote server discovery(SCGCQ01567177 port of SCGCQ01553588) 
 - Client: Handle Enable/Disable style for search Button(SCGCQ01567216 port of SCGCQ01539573) 
 - LSA Crashes after clicking on foreign configuration(SCGCQ01567307 port of SCGCQ01545262) 
 - Manual discovery of servers(SCGCQ01569264 port of SCGCQ01539471) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569569 port of SCGCQ01504080) 
 - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01570076 port of SCGCQ01563340) 
 - Converting the JBOD Pds to Unconfigured good PD during VD creation VD creation(SCGCQ01597581 port of SCGCQ01518204) 
 - Manual discovery of servers(SCGCQ01600837 port of SCGCQ01539471) 
 - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01615020 port of SCGCQ01552654) 
 - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01615042 port of SCGCQ01601386) 
 -(SCGCQ01633836 port of SCGCQ01599526) 
 - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01635183 port of SCGCQ01593855) 
 - Use schedular call for heavy operations for performance imporvement(SCGCQ01635665 port of SCGCQ01506032) 
 - Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01635761 port of SCGCQ01518113) 
 - JBOD Mode : WG: Even after clicking Convert JBOD the JBOD conversion page does not refresh with updated list(SCGCQ01635784 port of SCGCQ01617721) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676612 port of SCGCQ01670094) 
 - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676732 port of SCGCQ01670094) 
 -(SCGCQ01685548 port of SCGCQ01685009) 
 - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01686054 port of SCGCQ01685449) 
 - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687173 port of SCGCQ01686105) 
 - fixed: WG: managing the manually added server fails : windows(gateway(SCGCQ01697195 port of SCGCQ01682360) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716641 port of SCGCQ01716622) 
 -(SCGCQ01718985 port of SCGCQ01698211) 
 - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01788477 port of SCGCQ01629574) 
 - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880123 port of SCGCQ01876091) 
 - handling the session management(SCGCQ01892868 port of SCGCQ01829897) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01898263 port of SCGCQ01802344) 
 - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01901754 port of SCGCQ01827404) 
 - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives.(SCGCQ01904075 port of SCGCQ01893304) 
 - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904345 port of SCGCQ01901758) 
 -(SCGCQ01920699 port of SCGCQ01808698) 
 - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01921839 port of SCGCQ01829669) 
 - SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS(SCGCQ01921842 port of SCGCQ01803373) 
 - WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674) 
 - LSA Server: Populate the Drive Sector Size while reading the LD MFI command(SCGCQ01930623 port of SCGCQ01926876) 
 - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01557738 port of SCGCQ01539349) 
 - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01564629 port of SCGCQ01550970) 
 - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message(SCGCQ01564682 port of SCGCQ01547992) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01569579 port of SCGCQ01514206) 
 - Support from LSA back-end to allow JBODs to be converted to UG for advance VD creation(SCGCQ01597602 port of SCGCQ01519271) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01670841 port of SCGCQ01629821) 
 - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01676281 port of SCGCQ01615856) 
 - Server schema validation is failing(SCGCQ01676389 port of SCGCQ01619401) 
 - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01679003 port of SCGCQ01563343) 
 - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01680728 port of SCGCQ01677101) 
 - LSA taking more time to discover VMWare servers(SCGCQ01681092 port of SCGCQ01681069) 
 -(SCGCQ01697478 port of SCGCQ01685009) 
 - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716625 port of SCGCQ01716622) 
 -(SCGCQ01718980 port of SCGCQ01698211) 
 -(SCGCQ01749087 port of SCGCQ01698211) 
 - Modify Properties option is enabled for VDs which are part of Transport Ready Drive Group(SCGCQ01764894 port of SCGCQ01763056) 
 - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01826237 port of SCGCQ01761830) 
 - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation(SCGCQ01837378 port of SCGCQ01833791) 
 - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA(SCGCQ01851919 port of SCGCQ01841280) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856730 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01891168 port of SCGCQ01889547) 
 - CC VD creation option is coming in LSA when the CC VD (SATA SSD(SCGCQ01897144 port of SCGCQ01817275) 
 - Update the Windows Server 2019 OS name in LSA(SCGCQ01897178 port of SCGCQ01866322) 
 -(SCGCQ01920924 port of SCGCQ01818618) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921819 port of SCGCQ01856350) 
 - LSA 7.6 Client: Cosmetic replace drive selection issue(SCGCQ01566455 port of SCGCQ01539347) 
 - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01567176 port of SCGCQ01539326) 
 - WG: Alignment in Remote Server Discovery page changes when it is in List view and filtered with any one of the OS type.(SCGCQ01567193 port of SCGCQ01471834) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569137 port of SCGCQ01538253) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569138 port of SCGCQ01538253) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01569488 port of SCGCQ01540821) 
 - Client:Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01597592 port of SCGCQ01518206) 
 - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601608 port of SCGCQ01598515) 
 - WG: empty details for policy change displayed in events "Previous = Current Write Policy: Now = Current Write Policy:"(SCGCQ01635759 port of SCGCQ01625912) 
 - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01635779 port of SCGCQ01629821) 
 - TR VD should be excluded from the PR VD list(SCGCQ01677110 port of SCGCQ01677062) 
 - Implemented: Allow mixing of nvme drives to be mixed with SATA/SAS drives(SCGCQ01697042 port of SCGCQ01697026) 
 - Hercules : Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails(SCGCQ01789156 port of SCGCQ01731931) 
 - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01816428 port of SCGCQ01641760) 
 - Handling the set text mechanism in client(SCGCQ01886532 port of SCGCQ01850387) 
 - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01897181 port of SCGCQ01841473) 
 - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,(SCGCQ01915812 port of SCGCQ01906914) 
 - LSA 7.8:Import option is given for the Incomplete foreign VD(SCGCQ01921678 port of SCGCQ01865420) 
 - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) 
 - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) 
 - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01961510 port of SCGCQ01889547) 
 - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01697480 port of SCGCQ01681070) 
 - Add Virtual Drive option is available for DGs with Transport Ready feature set(SCGCQ01764885 port of SCGCQ01763052) 
 - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01828400 port of SCGCQ01538253) 
 - Fixed: Crash when pressing back button after logout(SCGCQ01892905 port of SCGCQ01865309) 
 - Remove un printable characters from LSA log(SCGCQ01901769 port of SCGCQ01901760) 
 - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) 
 - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives(SCGCQ01921580 port of SCGCQ01823858) 
 - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565119 port of SCGCQ01504080) 
 - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01569761 port of SCGCQ01555955) 
 - Unable to import foreign secured VDs with different security key(SCGCQ01731357 port of SCGCQ01670139) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01794950 port of SCGCQ01793057) 
 - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01817915 port of SCGCQ01793057) 
 - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) 
 - Server: LSA GUI Not Updating Security Key Info(SCGCQ01897099 port of SCGCQ01761801) 
 - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01564631 port of SCGCQ01540821) 
 - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01679329 port of SCGCQ01675460) 
 - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01698150 port of SCGCQ01590450) 
 - LSA needs proper message for max config import(SCGCQ01813925 port of SCGCQ01764977) 
 - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) 
 - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) 
 - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01564737 port of SCGCQ01514206) 
	
EnhancementRequests:
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399204) 
 - Part 2 of 2: Support TCG Opal 2.0 via SafeStore for VDs and SystemPD (Legacy JBOD) in RAID Mode and JBOD/SDS Modes(SCGCQ01599762) 
 -(SCGCQ01740789) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add "Replace Missing Drive" feature to LSA(SCGCQ01399205) 
 - Manually add server details to the list of servers(SCGCQ01539514) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01740787) 
 - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01401460) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746609) 
 - Manual discovery of servers(SCGCQ01539471) 
 - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01802344) 
 -(SCGCQ01599763) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746608) 


004.069.000.000  - Moderate Impact
---------------

Defects (20)
-.(SCGCQ01753405)
- Server: LSA GUI Not Updating Security Key Info.(SCGCQ01761801)
- CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275)
- Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404)
- Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01841473)
- LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856350)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209)
- fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01833469)
- LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ01838943)
- LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953)
- fixed: Info "1920 more drives can be added" need to change in LSA.(SCGCQ01827401)
- The display wrong location in page(SCGCQ01836732)
- LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01818960)
- LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives.(SCGCQ01850008)
- LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091)
- Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01866289)
- Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305)
- Security Key Confirm Text box should not accept the copy of anything.(SCGCQ01788477 port of SCGCQ01629574)
- SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856730 port of SCGCQ01856350)
- The LSA is failing to take into account current USED PDs from another configured VD during next VD creation.(SCGCQ01837378 port of SCGCQ01833791)
- SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in.(SCGCQ01828400 port of SCGCQ01538253)
- Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01817915 port of SCGCQ01793057)
- SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895)

EnhancementRequests (20)
- RTTrace API Changes.(SCGCQ01745568)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01802344)


004.062.000.000  - Moderate Impact
--------------
fixed:
Nginx versions since 0.5.6 up to and including 1.13.2 are vulnerable to integer overflow vulnerability in nginx range filter module resulting into leak of potentially sensitive information triggered by specially crafted request.https://nvd.nist.gov/nvd.cfm?cvename=CVE-2017-7529.

Defects (109)
- LSA server report for iMR Inv controller displays dedicatedHotSparePerDriveGroup is 0 under "maxLimit".(SCGCQ01375788)
- SCGCQ01393056: Enclosure ID is coming up as null in LSA.(SCGCQ01393056)
- WG: Error message not fitting inside the message box in "Enable Drive Security" page..(SCGCQ01442477)
- WG: Issues pertaining to 'Make JBOD Secure' Pop up.(SCGCQ01446801)
- PerfImp: Don't handle SLIM_EVT_EXCEEDS_MAX if there is no event requires complete refresh.(SCGCQ01447165)
- WG: UI Pattern in "Virtual Drive Settings" is not uniform while creating and modifying VD properties..(SCGCQ01447697)
- WG: "Change" button shown as disabled when user tries to change Behavior mode..(SCGCQ01450713)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG: success message box for "change personality" does not have proper border.(SCGCQ01453980)
- WG: Event Log table headers needs space - Cosmetic.(SCGCQ01460053)
- WG: Notification after saving the changes in "Manage Power Save Settings" needs cosmetic change..(SCGCQ01460078)
- Requested personality field is not updated for Ventura.(SCGCQ01465642)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)
- WG: Tooltip for help link in "Remote Server Discovery" page is not displayed..(SCGCQ01471842)
- WG: "Available UG drives" form is shown blank when "Type" is selected from ALL to any other drives..(SCGCQ01472186)
- WG: LSA showing inappropriate message after securing a DG using FDE security..(SCGCQ01472201)
- Buttons are inconsistent in Email Settings page of LSA.(SCGCQ01472752)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.().(SCGCQ01474461)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01482320)
- During Advanced Vd Creation PD selection order is not maintained by the client.(SCGCQ01498969)
- Display the ROC temperature in Fahrenheit as well along with Celsius.(SCGCQ01504619)
- WG: Hand mouse pointer is used in " Background Process progress " window , where it shows the name of background operations..(SCGCQ01505999)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Caps letter is expected in Settings for Alert settings successful and restore default value successful message..(SCGCQ01509253)
- WG: Sorting of drives by model number does not work for JBOD drives.(SCGCQ01511247)
- Do not allow the user to manage Personality Panel if set personalty is not supported.(SCGCQ01514527)
- SCGCQ01515443: WG: Typo in Event ID: 114 of PD state Change event related to sheild state.(SCGCQ01515443)
- 502 bad gate way observed on enclosure cable push/pull.(SCGCQ01524150)
- WG : LSA allows to add VD on offline DriveGroup and operation fails anyways.(SCGCQ01526342)
- MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01532725)
- LSA shows wrong diskgroup info when you have foreign PD.(SCGCQ01590450)
- Lenovo_18B: Not able to set max no of PD using set patrol read properties in LSA/Storcli.(SCGCQ01681070)
- Fixed: LSA handle count increase was observed.(SCGCQ01713154)
- Lenovo CIT 18B: LSA Linux doesn't have latest storelib.(SCGCQ01713580)
- SCGCQ01385340: Health is not coming proper after foreign config import..(SCGCQ01385340)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389892)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01419325)
- WG: Not all space in "Foreign Configuration" tab is clickable..(SCGCQ01467702)
- WG: Font style across the "Advanced Configuration" form should be made same..(SCGCQ01472063)
- Removing dead code from LSA7.5 stream..(SCGCQ01472185)
- WG: "Ok" button needs to be in caps in "Mixed listed drives" confirmation page and one more cosmetic change..(SCGCQ01472190)
- WG: There is no alignment for the error message while user changes the personality mode when PR is in progress..(SCGCQ01474932)
- WG: LSA is not allowing User to change No of PD's allowed for Patrol Read in Set PR properties through KeyBoard..(SCGCQ01479402)
- WG: Trying to clear configuration does not show any warning in server summary page regarding cached data, in CC page it shows.(SCGCQ01486698)
- WG: Select all check box is still selected even if one of the drive group is unselected while assigning HSP to existing DG.(SCGCQ01488141)
- WG: while creating FDE VD, type by default is selected as "All" in PD selection pane, unable to select all FDE drives.(SCGCQ01488169)
- Requested personality field is not updated for Ventura.(SCGCQ01494598)
- temperature change in controller is not refeclected in LSA..(SCGCQ01500344)
- Set patrol read window shows a time in past..(SCGCQ01503810)
-.(SCGCQ01508528)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01509259)
- WG: LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01509708)
- LSA Server: Set Patrol read is not shown when the volume is created with SSD.(SCGCQ01511260)
- SCGCQ01513209: WG: Simple configuration tab show invalid options before the raid level drop down list the supported raid levels.(SCGCQ01513209)
- WG : Advanced configuration tab gets disabled after secure erasing the FDE foreign drives.(SCGCQ01514728)
- SCGCQ01521013: MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01521013)
- MR 7.5_LSA: LSA keeps on refreshing during the background operations- Full init, RLM, CC etc.(SCGCQ01522807)
- WG: Behavior mode is missing in "personality management" window..(SCGCQ01523045)
- SCGCQ01525738: MR 7.5_LSA: Wrong nginx version is reported in linux ( SLES and RHEL ) Operating Systems..(SCGCQ01525738)
- Instance validation issues with LSA build 4.55 with IR3 controller.(SCGCQ01528425)
-.(SCGCQ01628332)
- WG: Current Profile is not selected by default in the table that lists the available profiles for the controller..(SCGCQ01442481)
- WG: "%" is accepted along with the input for Expand VD value - But not accepted for all..(SCGCQ01445384)
- WG: Partition line is required in Controller Properties Page..(SCGCQ01445396)
- WG: Status icon of physical drive is not changed after changing the state of the PD from rebuild to offline..(SCGCQ01461144)
- WG:LSA doesn't allow to secure more than one DG using FDE..(SCGCQ01472853)
- SCGCQ01474327: Handle dynamic length serial number as part of serial number VPD page 0x80.(SCGCQ01474327)
- WG: GUI : Cosmetic issues in clear configuration notificationp.(SCGCQ01486692)
- WG: LSA does not notify the user with notification on starting the VD initialization.(SCGCQ01487270)
- WG: able to add VD for scheduling consistency check even after all the VD's have been deselected.(SCGCQ01489509)
- WG:Add physical Drive button is clickable before VD list is loaded while scheduling CC or PR, no notification to user to wait.(SCGCQ01489885)
- LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01489942)
- LSA: Virtual drive, spare and drivegroup is not supported for IT but seen in URI response for Physical drives..(SCGCQ01500099)
- WG: Selection of different drive type is activated after few clicks.(SCGCQ01503786)
- RWC3 launch tab is showing the LSI Storage Authority.(SCGCQ01503896)
- WG : Pop up for securing FDE drive has inconsistency in text.(SCGCQ01507972)
- In settings window "Restore Default Alert settings" button is not saving the default values.(SCGCQ01508002)
- WG: Confirm Check box is not aligned with the "Enable Security" button.(SCGCQ01511250)
- LSA WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01511390)
- WG:Server Logs does not contain status of energy pack it mentions "Requested element not found in the stack.":error "69634".(SCGCQ01512318)
- WG: Spell Check issues with "message_en.js" used for displaying the GUI notification.(SCGCQ01512377)
- Sorting of Event logs wrt View Events and Download Logs.(SCGCQ01512750)
- WG: LSA add physical Disks pane shows empty drive list even if there are 182 drives for adding for RLM operation.(SCGCQ01513656)
- Controller operations schema instant validation is failed.(SCGCQ01514528)
- WG: LSA shows the message "The virtual disk has not been initialized" even when 32 VD's have been selecte.(SCGCQ01521694)
- Lenovo-18B: IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3.(SCGCQ01595641)
- WG: "Virtual Drive expanded successfully" message is still shown even after the page refresh post VD expansion..(SCGCQ01445693)
- WG: Cosmetic changes required in tooltip messages of Configure options in Controller Actions..(SCGCQ01447797)
- WG: Space is required between RAID and it's type in Available UG drives form and one more cosmetic change..(SCGCQ01472194)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- LSA: partial VD hide operation is failing..(SCGCQ01484118)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01506090)
- WG:Launching LSA using ip:2463 in browser, User can see the HOME page flash before redirecting to Remote discovery.(SCGCQ01439795)
- WG: LSA displays empty box instead of "Action Successful" for "Prepare for removal" and "Undo prepare for removal".(SCGCQ01447823)
- WG: "Adding the virtual drive will add the corresponding virtual drives for PR" is not shown when "select all" box is used..(SCGCQ01461133)
- WG: Size of "Back" & "Save" buttons are not same once the user saves the changes after scheduling CC.(SCGCQ01472749)
- WG: Hand symbol is not seen for close button while Adding drive during reconstruction of a DG.(SCGCQ01473748)
- Disabling the add PD button.(SCGCQ01488036)
- WG: no notification shown on assigning dedicated hotspare to existing DG.(SCGCQ01488155)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01509681)
- WG: Error message on a failed operation of RLM in displayed outside the allocated space.(SCGCQ01515263)
- WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01442471)
- WG: Expand windows is showing the capacity in decimal value with too many integers after decimal point..(SCGCQ01445686)
- Address Code review defects for ER SCGCQ01416373.(SCGCQ01455923)
- WG: Ambiguous "Success" message needs to be changed for disabling drive security.(SCGCQ01461177)
- Cannot import foreign configuration from LSA.(SCGCQ01524354)
- WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space.(SCGCQ01563343)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSABug.(SCGCQ01599526)

EnhancementRequests (20)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
-.(SCGCQ01404233)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461207)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- LSA: Make heavy operation by wrapping scheduler call.(SCGCQ01416373)
 - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443721)
- LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443731)
- Support drive Select ALL functionality in LSA GUI PD Operations and Mixing of drives during vd creation.(SCGCQ01454110)
- SCGCQ01454353: Retrieve and process the ESXi events in a single shot.(SCGCQ01454353)
-.(SCGCQ01454367)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- We will be removing the confirmation popup from all the actions as we got here from multiple forms like this pop up is annoying.(SCGCQ01447015)
- Support drive Select ALL functionality in LSA GUI VD/DG Operations.(SCGCQ01453114)
-.(SCGCQ01472631)

CSETActivities (87)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411631 port of SCGCQ01397546)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01420224 port of SCGCQ01419325)
- LSA service is not working in Linux.(SCGCQ01443712 port of SCGCQ01442733)
- WG: Event Log table headers needs space - Cosmetic..(SCGCQ01464556 port of SCGCQ01460053)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01466763 port of SCGCQ01424621)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Updated PD firmware version is not reflecting even after LSA refresh..(SCGCQ01501204 port of SCGCQ01382013)
- Cisco_Plumus_LR :Proper spacing should be there in between Event and History in view event logs "EventHistory not generated"..(SCGCQ01502201 port of SCGCQ01385344)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure.(SCGCQ01503907 port of SCGCQ01315392)
because of which the issue.(SCGCQ01503926 port of SCGCQ01288032)
- fixed: clear drive should not be candidate drive for create configuration.(SCGCQ01503958 port of SCGCQ01196088)
- Fixed: Span order is in reverse compare to other apps.(SCGCQ01504234 port of SCGCQ01330269)
- LSA shows max pd for Raid 1 without checking support of Raid 1E.(SCGCQ01514472 port of SCGCQ01513338)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531154 port of SCGCQ01521114)
- Making rebuild drive offline lsa gets 404..(SCGCQ01564627 port of SCGCQ01542412)
- LSA Crashes after clicking on foreign configuration.(SCGCQ01564739 port of SCGCQ01545262)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565025 port of SCGCQ01504080)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01565116 port of SCGCQ01555955)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621 )
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01599402 port of SCGCQ01563340)
- MR7.6_LSA: No Foriegn configuration details is shown in LSA.(SCGCQ01605344 port of SCGCQ01581943)
- fixed: logout causing unexpected behavior during end cim connection for vmware systems.(SCGCQ01609343 port of SCGCQ01578248)
- SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page..(SCGCQ01614982 port of SCGCQ01355833)
- LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group..(SCGCQ01617930 port of SCGCQ01401460)
- SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01620406 port of SCGCQ01506090)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01634072 port of SCGCQ01473733)
- Raid 1 Volume creation using 4 drives is displayed as Raid 1E.(SCGCQ01686231 port of SCGCQ01686106)
- Cannot use Special Characters in Domain Name for LSA Login.(SCGCQ01747012 port of SCGCQ01745768)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected..(SCGCQ01448948 port of SCGCQ01442107)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01460039 port of SCGCQ01451571)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts..(SCGCQ01465657 port of SCGCQ00903348)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01466743 port of SCGCQ01451571)
- LSA server giving null for enclosure serial number.(SCGCQ01466744 port of )
- Address Code review defects for ER SCGCQ01416373.( port of SCGCQ01445713)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01484107 port of SCGCQ01482320)
- Added fwflash status as part of controller health status.(SCGCQ01503830 port of SCGCQ01375153)
- While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure because of which the issue.(SCGCQ01503955 port of SCGCQ01288032)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01514258 port of SCGCQ01506045)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01514469 port of SCGCQ01507989)
- Allows raid 1e input even if RAID 1E is not supported by fw.(SCGCQ01514756 port of SCGCQ01513331)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01564633 port of SCGCQ01562368)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- WG: LSA service crashes on trying to login with URI having incorrect mac address of the server.(SCGCQ01615042 port of SCGCQ01601386)
- MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01685343 port of SCGCQ01641760)
-.(SCGCQ01685548 port of SCGCQ01685009)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687173 port of SCGCQ01686105)
- LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716641 port of SCGCQ01716622)
- SDS/HBA progress issues.(SCGCQ01460070 port of SCGCQ01052983)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01460084 port of SCGCQ01435908)
- SCSI UNMAP switching support from LSA GUI.(SCGCQ01461211 port of SCGCQ01461207)
- C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01501225 port of SCGCQ01321211)
- Cisco - CSCve68492 - Storage Logs display a blank event when a secure PD is unlocked.(SCGCQ01503902 port of SCGCQ01359128)
- SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01514773 port of SCGCQ01509259)
- WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01526363 port of SCGCQ01509681)
- SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message.(SCGCQ01564682 port of SCGCQ01547992)
- LSA: Warning Message needs to be changed when there is Controller firmware update failure.(SCGCQ01604992 port of SCGCQ01564526)
- SCGCQ01599526: Lenovo PE: Memory Leak in LSA.(SCGCQ01633836 port of SCGCQ01599526)
- Secure Jbod unlock is not showing the proper error message in LSA.(SCGCQ01680728 port of SCGCQ01677101)
- LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687172 port of SCGCQ01686080)
- Cisco - CSCvi84075 - LSA, CTRL-R and HII doesn't display the foreign config when MAX VDs are present.(SCGCQ01718980 port of SCGCQ01698211)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460090 port of SCGCQ01460076)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460400 port of SCGCQ01448976)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01481410 port of SCGCQ01474461)
- LSA build script automation for VBAS environment.(SCGCQ01497385 port of SCGCQ01385344)
- Activity to check-in version files in common.(SCGCQ01520315 port of SCGCQ01512599)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- LSA Client 7.6: SPAN drives order is not maintained.(SCGCQ01614833 port of SCGCQ01539355)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline..(SCGCQ01443689 port of SCGCQ01442554)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux..(SCGCQ01480902 port of SCGCQ01479375)
- LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs..(SCGCQ01564943 port of SCGCQ01534444)
- Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565119 port of SCGCQ01504080)
- Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time.(SCGCQ01676612 port of SCGCQ01670094)
- LSA Wont display foreign data when enclosure information in not populated properly.(SCGCQ01686054 port of SCGCQ01685449)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
-.(SCGCQ01564591 port of SCGCQ01515389)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01460393 port of SCGCQ01436886)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive..(SCGCQ01564629 port of SCGCQ01550970)
- LSA WG Fury IT: Controller type is showing as IR for IT card.(SCGCQ01564631 port of SCGCQ01540821)
- I/Os are not recover after drives pull for DHSP to rebuild..(SCGCQ01564737 port of SCGCQ01514206)

4.011.000.000 - Moderate Impact
-------------
Defects (234)
- SDS/HBA progress issues.(SCGCQ01052983)
- Fixed: Added relevant null pointer checks.(SCGCQ01319978)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01321474)
- Start PatrolRead success dialog box needs change in alignment.(SCGCQ01324866)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01325783)
- Link speed is not displaying any details in LSA.(SCGCQ01326129)
- Defect to check in code review defects.(SCGCQ01329391)
- Client js file changes for 7.3.(SCGCQ01331593)
- On Successful Firmware flash client displays improper Icon Message.(SCGCQ01332708)
- Control panel of LSA Help & support link still has reference to LSI. should be changed to broacom.(SCGCQ01337321)
- LSA asks for user permission to navigate away on clicking home button after creating simple configuration.(SCGCQ01338009)
- WG: GUI Issues pertaining to FW flash ER implementation SCGCQ01273627: Request to improve message displayed during FW Update.(SCGCQ01342542)
- IR Card global hot spare assignment is not refreshing the page.(SCGCQ01345357)
- Cisco_HSW_Validation_LSA: LSA accepting decimal values for "Set Adjustable Task Rate" which is saved as round value.(SCGCQ01345553)
- LSA 7.3 Client Coverity fix.(SCGCQ01347309)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01350435)
- WG:descripancies in update firmware page after selecting load bios option.(SCGCQ01350865)
- SCGCQ01350908: WG:Temperature of Unconfigured Drive is displayed as 0C under More properties.(SCGCQ01350908)
- WG:LSA displays Redhat icon in remote discovery page ,though SUSE is installed in system.(SCGCQ01351455)
- LSA taking the max VD size value when the user presses ENTER after specifying the VD size.(SCGCQ01356216)
- SCGCQ01356217: WG: LSA Service crashes on trying the PD details of the simple config created.(SCGCQ01356217)
- LSA_MR_7.3_Alpha: Save option can be grayed out or disabled after user saves the changes for schedule CC.(SCGCQ01357152)
- LSA_MR_7.3_Alpha: LSA doesn't display consistent Foreign Configuration information to the user.(SCGCQ01358048)
- WG: Incorrect notification shown after selecting 32 virtual drives.(SCGCQ01358095)
- SCGCQ01358097: LSA_MR_7.3_Alpha: Space optimization between the size value & size unit is needed in foreign configuration page.(SCGCQ01358097)
- LSA_MR_7.3_Alpha: User cannot select "Advanced Configuration" by clicking on the description below it in Server landing page.(SCGCQ01358122)
- LSA_MR_7.3_Alpha: Space Alignment for better presentation needed in Server Profile Page.(SCGCQ01358148)
- LSA_MR_7.3_Alpha: Percentage value for the Background Operations is not seen if browser is zoomed.(SCGCQ01358261)
- LSA crash when service starts with empty LSA.conf file.(SCGCQ01358264)
- SCGCQ01358892: Buttons "Try Updating Again" is not highlighted when user attempts to flash the firmware after any failure.(SCGCQ01358892)
- SCGCQ01358947: WG: Invalid text Content displayed on selecting multiple Virtual drives/Physical Drives.(SCGCQ01358947)
- WG: "Select Personality" dropdown lists the current personality first by default.(SCGCQ01359030)
- WG: Clickable "hand icon' is not displayed when we move cursor over Bus dev text of controller in Server summary page.(SCGCQ01359034)
- SCGCQ01372670: When User tries to click on Update FW Button, LSA asks for Navigation Confirmation without displaying Update FW page for IT.(SCGCQ01372670)
- "Add CacheCade-SSD VD" tab getting greyed out after deleting created vd,even if physical drive is selected under "Add SSD pd".(SCGCQ01372722)
- WG: VD creation fails when multiple VD's are created with 1MB size.(SCGCQ01373500)
- "Finish" button in Modify drive group work even if its grayed out.(SCGCQ01374945)
- WG: Issues pertaining to Controller Diagnostic logs.(SCGCQ01375839)
- WG: GUI Issues pertaining to Instant secure erase of an FDE Drive.(SCGCQ01375858)
- There is a mismatch about Backplane (Enclosure) "Product ID" and "Enclosure Model" in LSA.(SCGCQ01376005)
- Spare URI does not respond on iMR Invader.(SCGCQ01376605)
- WG: After physically removing the PD from the R10 DG, the DG Span tab does not load.(SCGCQ01376781)
- "Since Log Clear" does not create the last event "Log Clear" in Var/log/messages.(SCGCQ01376849)
- WG: LSA does not list the Drive Group Tab , on creation of 240 VD (15 DG, 16 VD in each of DG) and reinstalling the LSA.(SCGCQ01378585)
- WG: Windows Application Event viewer lists 31 events instead of 30, after installing LSA with the option "Since Last reboot".(SCGCQ01378669)
- WG: LSA does not automatically refresh on hiding an Degraded DG.(SCGCQ01378693)
- Client: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01378778)
- Client: WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01378782)
- WG: unable to start VD initialization on 32 VD's when there are 240 VD created & Foreign configuration present in system.(SCGCQ01378808)
-.(SCGCQ01378812)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01379795)
- WG:In premium features Safe ID & Serial Number needs to be highlited for better understanding.(SCGCQ01379818)
- WG: Close button can be given with a "hand" symbol in Compare and select form like all close button in other form has.(SCGCQ01380587)
- WG: Available Unconfigured drives is not formatted properly for display.(SCGCQ01380591)
- WG: Domain Authentication is shown as Default in "MAnage Server Page".(SCGCQ01380642)
- Size increment button is not working while modifying a VD that is created in MB size.(SCGCQ01380830)
- WG: "Advanced and Simple Configuration" is enabled when UG drives are "prepared for removal" and no other drives are left.(SCGCQ01380977)
- SCGCQ01383828: LSA service crashes while trying to access the IR3 controller.(SCGCQ01383828)
- WG:VD properties were not well partitioned for CacheCade - SSD config , compare to normal VD creation in HDD.(SCGCQ01384561)
- WG: Few enhancements needed in VD Expand form.(SCGCQ01389165)
- SCGCQ01389195: WG: Naming convention for VD can be made consistent for the VD's created through Advanced and Simple configuration.(SCGCQ01389195)
- Enter key is functioning as a backspace in "Set Adjustable Task Rate" - Can be disabled.(SCGCQ01389203)
- LSA mail server settings does not allow to enter name of smtp server.(SCGCQ01389204)
- WG: No. of VD's available to create is not shown properly for spanned vd's when span depth is modified.(SCGCQ01389421)
- Storcli: Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01392000)
- WG: More Actions for drive is not working after staring and stopping Clear operation under Drives tab.(SCGCQ01392056)
- WG: User has to click twice on the table header to change the sorting order for any table in LSA.(SCGCQ01393336)
- Copyright link is taking to top of the page rather taking to Broadcom website.(SCGCQ01393706)
- WG: PD state info is not updated properly in the Drives tab after PD's are converted from online to offline.(SCGCQ01393771)
- WG: "Clear" and "Rescan" buttons could be highlighted for the better look in Foreign Configuration Tab.(SCGCQ01394954)
- "Add Virtual Drives" is grayed out for specific VD sizes after user presses "tab-alt" keys.(SCGCQ01398966)
- WG: Verify and Sign In Buttons are overlapping in list view in Manage Server Page.(SCGCQ01399610)
- LSA is not showing "Activate..." button for Premium Features when it is navigated after "Update Firmware" page.(SCGCQ01399670)
- WG:LSA sending email alert notifications to user which doesn't exist.(SCGCQ01418580)
- Drives under both Physical drives and Span drives tab are allowed to select simultaneously.(SCGCQ01428129)
- Login to VMware is taking at time more than 30 seconds.(SCGCQ01429431)
- Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01435908)
- WG:while editing a created VD, user cannot increase the VD size in MB .Only can decrease the size.(SCGCQ01438268)
- WG:LSA is not sorting properly the drives with different capacity of units i.e TB and GB.(SCGCQ01439751)
- WG: View server profile does not contain info on the Device id, which is sorted according to device id itself.(SCGCQ01440773)
- WG: operation of Combining JBOD drives with & without files system to move to Unconfigurued good is partially successful.(SCGCQ01440778)
- WG: Space required between two strings in the description of "Enable Drive Security".(SCGCQ01442479)
- WG: LSA Displays "Error Code:1:An user is already Logged in with Different Credentials" even user is using same credentials.(SCGCQ01442773)
- WG: LSA is changing to latest login user account though it is already logged with different User Account in different Tab.(SCGCQ01442774)
- WG: No. of UG drives are improperly updated in the Drives header tab when replace operation is triggered on a physical drive.(SCGCQ01444724)
- WG: No. Of Power Supplies info displayed is overlapping on the enclosure details. Need proper display alignment.(SCGCQ01444794)
- LSA showing 'binaryPath:./LSA' during service start in Linux.(SCGCQ01445709)
- LSA server giving null for enclosure serial number.(SCGCQ01445713)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01445719)
- WG: Description for event Code"579" is '0" in LSA event logs.(SCGCQ01446803)
- WG:"Disable Data Protection" is not updating in LSA until user do a manual refresh.(SCGCQ01447843)
- SCGCQ01448707: WG: LSA Event logs has enquiry info for Vendor, model and serial numbers appended with $ symbols.(SCGCQ01448707)
- WG: Inconsistency seen w.r.t making drive online while RLM is in progress.(SCGCQ01449722)
- WG: Event log page is navigating to change personality when the behavior mode is set from other tab of the same browser.(SCGCQ01450719)
- DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571)
- WG:Controller health status not updated on moving JBOD drive from offline --> online, personality : JBOD.()
- LSA Server: Handling of additional events in Cache module.(SCGCQ01451573)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01464514)
- [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045)
- WG: Enclosure ID is shown "Unknown" for NVMe JBOD only in event logs, Profile id=11.(SCGCQ01291162)
- WG: LSA page does not refresh on starting Full initialization on 240 VD.(SCGCQ01292183)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- 7.3 Client : Coverity defects check-in.(SCGCQ01308624)
- SCGCQ01309034: Coverity defect fixes check-in.(SCGCQ01309034)
- Fixed: Code maintainability issue.(SCGCQ01318344)
- coverity defect fies for : Suspicious use of non-short-circuit boolean operaton.(SCGCQ01320079)
- In Simple Config, if user select a VD and select the check box of "Assign HSP", VD size is getting changed to different size.(SCGCQ01321225)
- WG: LSA notifies user that VD will be deleted after VD erase even if the option was not selected.(SCGCQ01325795)
- WG: user notification appearing after user starts/stops the initialization on multiple VD's needs to be updated.(SCGCQ01326134)
- LSA doesn't show FW component name while FW flash operation.(SCGCQ01337028)
- WG: Multiple options of RLM are selected together for radio button used to select one of the 3 RLM operations.(SCGCQ01342615)
- LSA does not display "Link Speed" for phy 8 properly for iMR Ventura.(SCGCQ01355929)
- When the CC is scheduled as "Continuously", it is not reflected in UI after saving the changes.(SCGCQ01357007)
- Warning message has to be corrected in Foreign configuration page and one more hyperlink issue.(SCGCQ01358066)
- LSA is not taking "dot(.)" from num pad , but taking "dot(.)" form keypad while specifying the vd capacity.(SCGCQ01358908)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01364736)
- WG: LSA displays the notification "This operation can be performed only on 32 drives at a time" 32 times.(SCGCQ01373067)
- WG: Global hotspare & Dedicated hotspare are displayed as plural entities for every hotspare listed in physical drive tab.(SCGCQ01375707)
- WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01375778)
- fixed: Min & Max of "PdRaidLevel_1E" under the "pdsForRaidLevels" is populated even though it is not supported in iMR.(SCGCQ01375817)
- WG: Other hardware tab lists wrong count of list of hardware connected when enclosure connected in multipath.(SCGCQ01376109)
- WG: View server profile contents exceed the border limits of the LSA page.(SCGCQ01378556)
- SCGCQ01378774: WG: Information of the virtual drive info and PD's involved in DG vanishes on removing & inserting the PD back from a DG.(SCGCQ01378774)
- WG: Links present in Backplane properties are so light that they look like grayed out. Needs enhancement.(SCGCQ01380680)
- WG: User is allowed to click on "Next" button even if page is not completely updated during the VD creation & RLM operations.(SCGCQ01381734)
- GUI Issues found in Advanced Configuration page.(SCGCQ01381764)
- Firmware flash message should have "new" removed from string.(SCGCQ01382062)
- LSA getting logged in , even if the password is wrong.(SCGCQ01388957)
- "%" is allowed for entering no. of seconds for locating the drives.(SCGCQ01389182)
- WG: Size limit warning is thrown if the user is giving valid size using spinner button while modifying VD.(SCGCQ01389340)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01389483)
- Spinner Button for increase and decrease size is not working when the size is 1.09 TB.(SCGCQ01392053)
- WG: "Username" has to be grayed out when user start typing in the login page of "Manage Server Page".(SCGCQ01393764)
- WG: UG Drives count is not updated properly after modifying a DG.(SCGCQ01393774)
- Phase 5 IT LSA - EFI-BSD version is not displayed fully when Version length is more than 12 characters.(SCGCQ01394914)
- Mismatch in enclosure properties between LSA and storecli utility.(SCGCQ01395021)
- WG: "Managing SAS Storage Link Speed" opens up on clicking help topic of "Manage PCIe Storage Interface".(SCGCQ01395075)
- when clicking on more actions for any UG drives to make DHS,the options remains as it is in LSA though the operation is done.(SCGCQ01403884)
- WG: Like "Flash Firmware" button in "Update Firmware" page, "Update" button should also have hand symbol & one more issue.(SCGCQ01405822)
- WG: while expanding exiting VD, the expand VD page is not consistent.(SCGCQ01416379)
- Fixed: WG: LSA conf does not contain the perf mode settings options configurable.(SCGCQ01422214)
- WG: Clicking on "Benefits of each MegaRAID Advanced Software Option" in premium feature is not taking to proper link.(SCGCQ01428156)
-.(SCGCQ01428383)
- LSA doesn't allow creating spanned Raid levels with 2 spans using more than 32 drives.(SCGCQ01435647)
- API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01436886)
- WG : "Replace Drive "window needs improvement to look uniform.(SCGCQ01439805)
- when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01440772)
- WG: LSA displays the property Drive Security Capable as 'No' even when security is supported.(SCGCQ01442209)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01443879)
- WG: Confirmation Message has to be changed when more than one drives are converted from JBOD to UG state.(SCGCQ01444672)
- SCGCQ01445818: MR 7.4_Alpha_LSA does not find a server in RHEL 7.4.(SCGCQ01445818)
- WG: LSA times out after "Clear Configuration" command is issued when there is a OFFLINE DG present.(SCGCQ01447788)
- WG: Size for the VD is not updated properly when edited during VD creation.(SCGCQ01447791)
- WG: An extra "." needs to be removed in the event description for "Initialization complete on VD".(SCGCQ01449783)
- WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733)
- WG: Raid 50 Vd Creation fails on unselecting drives after changing span during VD creation.(SCGCQ01309542)
- Coverity Defects - Performance Inefficiencies.(SCGCQ01313878)
- Fixed: Coverity: Class hierarchy inconsistencies.(SCGCQ01318333)
- Client: Coverty defect fixes check-in.(SCGCQ01318336)
- VD size getting increased while creating VD using simple config - Regression.(SCGCQ01341947)
- WG: Once the FW update is completed LSA shows junk character in the notification about firmware flash was successful.(SCGCQ01342536)
- SCGCQ01348082: LSA: Loopback occurs during launch. (intermittent issue).(SCGCQ01348082)
- Expand page is not closed when opened for second time.(SCGCQ01357224)
- "Add Virtual Drives" is disabled when user changes from invalid size to valid size through increment button.(SCGCQ01358299)
- WG: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01375255)
- "Server Profile" displays blank back plane info for ctrl-1.(SCGCQ01375992)
- LSA Client : Foreign Configuration Panel issues with locked and unlocked foreign drives.(SCGCQ01378050)
- DG Actions menu is not shown properly after zooming in when VD's are hidden.(SCGCQ01380663)
- WG: Size range warning is not shown while modifying VD when unit is selected from MB to GB.(SCGCQ01380818)
- LSA Evevnt: Access policy for HIDDEN/Transport is coming as Empty.(SCGCQ01380828)
- LSA Server: User is provided with Hide and Un-Hide option though there is no HIDE performed on a VD.(SCGCQ01380845)
- WG: LSA service crashes on hiding and unhiding DG's with dedicated hotspare.(SCGCQ01380912)
- SCGCQ01383765: Resolve linux server compilation issues.(SCGCQ01383765)
- WG: Reconstruction progress is not refreshed even after the VD is cleared on which reconstruction was happening.(SCGCQ01383800)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01389392)
- WG: Clicking on View server profile just before controller console page loads results in blank page.(SCGCQ01396731)
- WG: "DG degraded notification" is not auto-refreshed after Raid5 VD is brought from offline to online.(SCGCQ01398964)
- WG: When LSA is configured with NAT server, it is shown twice in the Remote Discovery Page.(SCGCQ01401484)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01401546)
- WG: Hidden links present in premium features page.(SCGCQ01412883)
- WG:VD properties details need some changes to look uniform across the application.(SCGCQ01418574)
- WG: Help link for Premium Features is opening in dual tabs.(SCGCQ01428169)
- LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected.(SCGCQ01442107)
- WG:LSA is not showing the options "Pause Patrol Read|Abort Patrol Read" when PR background operation is running.(SCGCQ01442350)
- WG:when user is closing the message box for "Clear Configuration",the "X" symbol is not shown with hand symbol.(SCGCQ01442356)
- LSA service is not working in Linux.(SCGCQ01442733)
- WG: Invalid text"Each_Frehole" present in Pop up of Adding VD to existing Drive group.(SCGCQ01446454)
- WG: "Add Hot Spare" Button is enabled after selecting and deselecting the drives.(SCGCQ01448882)
- WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01448976)
- WG: Event with ID 552 is not updated properly. Information on Mode is empty.(SCGCQ01450725)
- LSA Client: SDS/HBA progress issue.(SCGCQ01459948)
- System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989)
- LSA not giving the Un Hide All Virtual Drives operation when DG contain Hidden and normal VDs.(SCGCQ01308440)
- Coverity Defects fixes for Stream LSA7.3.(SCGCQ01311864)
- LSA7.3: Coverity defect fixes in Server code.(SCGCQ01316168)
- Coverity: Integer handling issues.(SCGCQ01318418)
- LSA Client : IR/IT Multiple Options are allowed in Update Firmware Screen.(SCGCQ01343645)
- Add hot spare page cosmetic issues.(SCGCQ01358219)
- WG:Change button is active even if button appears inactive for "Change personality", fails with an inappropriate notification.(SCGCQ01358967)
- FW last modified time is not coming properly while FW upload.(SCGCQ01359056)
- WG:while editing created vd for CacheCade - SSD Caching Configuration,the write policy tab is coming down.(SCGCQ01380641)
- WG: In "Advanced Configuration" page, Raid settings and Drive Attributes are not numbered properly.(SCGCQ01380646)
- WG: Issues pertaining to "Server is taking long to respond" LSA page.(SCGCQ01383122)
- SCGCQ01395189: WG: "Manage PCIe Storage Interface" displays empty table for MR Ventura controller with profile id 13.(SCGCQ01395189)
- WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01415223)
- WG: Question mark missing in "Erase" confirmation form.(SCGCQ01415923)
- WG: Extra "." (dot) has to be removed in VD Initialization confirmation message and one more cosmetic issue.(SCGCQ01428137)
- WG: Instance Validation is failing for driveGroupConfigurationService-schema.json in MR_Ventura card.(SCGCQ01443739)
- MR7.4_Alpha_LSA crashed when trying to download firmware RHEL 7.4.(SCGCQ01447240)
- LSA Client Refresh issue while making more than one drive(s) offline when RLM is in progress.(SCGCQ01449870)
- WG: No success /failure Notification is shown in server summary page on making a offline drive online.(SCGCQ01451575)
- WG:2 Spans(Modify Span Depth) is showing in "Advance configuraton" page even if their is no PD left for the config.(SCGCQ01452129)
- WG:when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01464425)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01479375)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ00903348)
- LSA should not allow to select the check box of VD and PD simultaneously on xSDS-None mode.(SCGCQ01323724)
- Issue : Instant Secure erase option is seen when FDE and NON-FDE drives are selected.(SCGCQ01326164)
- SCGCQ01332799: Resolve LSA server compilation issue.(SCGCQ01332799)
- LSA conf file not being updated While changing the default port 2463 and 9000 to some other free ports in windows_8.1_x64.(SCGCQ01375895)
- WG: "?" symbol is in the centre of the Drive erase page unlike in other pages.(SCGCQ01383763)
- WG: ESXi server name is not completely visible in Manage Servers page.(SCGCQ01389332)
- WG: UI Enhancement: Hand symbol has to be given for the "Modify VD" icon for better user experience.(SCGCQ01389343)
- Foreign Configuration issues locked and unlocked foreign drives count.(SCGCQ01391010)
- Action successful message needs to be modified for better User experience.(SCGCQ01392057)
- spandepth need one space between span & depth, to look uniform across the application.(SCGCQ01413225)
- Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01423352)
- LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01460076)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01394281)
- WG: Help link for "Activate Features" after providing the Activation key is not working.(SCGCQ01398969)
- SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01424621)
- Added the "?" at the end of instant secure erase. But there no issue related line in more actions panel please find the attached screenshot.(SCGCQ01442352)
- Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01474461)
- 'X' symbol for removing physical drives are not highlighted when the drives are allowed to be removed.(SCGCQ01350436)
- API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754)

EnhancementRequests:
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- SLIR3: Change build scripts and makefiles to account for change in directory structure and new name of the library.(SCGCQ00293713)
-.(SCGCQ01389581)
- LSA Page tab name should be changed.(SCGCQ01401514)
-.(SCGCQ01416369)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444590)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- SLIR3: Remove Libsysfs dependency in StoreLibIR3.(SCGCQ00293709)
- Adding Solaris and Sparc X64 bit support in SLIR3.(SCGCQ00922699)
- Change library name to SLIT.(SCGCQ00933175)
-.(SCGCQ01309820)
- LSA Server : [Lenovo Purley] Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01352474)
- HBA nvdata version in Decimal Format in LSA.(SCGCQ01365643)
- WG: Dedicated Hot spare Notification pop-up alignments.(SCGCQ01401505)
- Schedule API changes for time consuming APIs.(SCGCQ01422386)
- MR7.4: Support for FW ER:SCGCQ01389581 in LSA Server.(SCGCQ01428115)
- Update the WebServer Nginx to fix the latest Security Vulnerabilities.(SCGCQ01452493)
- SAS3 Ph8 --- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00729472)
- LSA Client: Handle Progress events without initiating individual API calls.(SCGCQ01416371)
- LSA: Make operation call with query parameter.(SCGCQ01424479)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- WG: Landing page - Graphics improvements.(SCGCQ01401517)
-.(SCGCQ01412749)
- Support for FW ER:SCGCQ01389581 in LSA Client.(SCGCQ01428113)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340)
- LSA7.3: LSA to hide the Empty back plane based on the property field in the LSA.conf file.(SCGCQ01312022)
- LSA: Make operation call with query parameter.(SCGCQ01416374)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- SCGCQ01250909 - [Lenovo Purley] - Retrieve Boot Events and Maintain it as part of Event History.(SCGCQ01291488)
- Client: EPMR12 porting to MR7.3.(SCGCQ01304973)
- Client: Provide pending profile details in LSA.(SCGCQ01331947)
- LSA Server: EPMR12 defect/feature porting to MR7.3.(SCGCQ01307382)
-.(SCGCQ01356193)
-.(SCGCQ01375857)
- WG: In Remote discovery page Self server is always listed in the last.(SCGCQ01378666)
-.(SCGCQ01472631)

CSETActivities:
- VMware LSI Out of Box driver feature reconciliation.(SCGCQ00696009 port of SCGCQ00652798)
- Provide a StoreLibIR2 deb package to work on Ubuntu.(SCGCQ00795333 port of SCGCQ00630108)
- WG: No Units are displayed for Event ID: 545: Information about super cap health.(SCGCQ01297685 port of SCGCQ01291338)
- LSA throws inappropriate error while attempt to start controller firmware upgrade when pinned cache present on controller.(SCGCQ01297819 port of SCGCQ01288364)
- CSCvd88927 - LSA is displaying drives' type string inconsistently for HDD/SSD so it needs to display consistently.(SCGCQ01331599 port of SCGCQ01316465)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336569 port of SCGCQ01313804)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337104 port of SCGCQ01332737)
- Hercules LSA : Schedule CC button does not allow to click on the whole button.(SCGCQ01339214 port of SCGCQ01337027 )
- PR on all drives are not aborted properly until page refresh is done.(SCGCQ01342568 port of SCGCQ01340808)
- No. of steps shown in "Modify Drive Group" page is not correct.(SCGCQ01343651 port of SCGCQ01341921)
-.(SCGCQ01345364 port of SCGCQ01342479)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01345398 port of SCGCQ01332912)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347171 port of SCGCQ01346904)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347220 port of SCGCQ01346908)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347221 port of SCGCQ01346908)
- Cisco_HSW_Validation_LSA: "Simple Configuration" page that appears after creating a simple config is blank.(SCGCQ01347224 port of SCGCQ01345554)
- Cisco_HSW_Validation_LSA: Character limit warning for VD name is not shown while modifying the VD during VD creation.(SCGCQ01347232 port of SCGCQ01345557)
- Cisco_HSW_Validation_LSA: VD Size limit check is not working when user modifies the value of the size.(SCGCQ01350834 port of SCGCQ01346906)
- Cisco_HSW_Validation_LSA: Prepare for removal menu is still displayed even after the option is selected and event is updated.(SCGCQ01350837 port of SCGCQ01338290)
- "%" symbol followed by integer value should not be allowed for the user to enter the size during VD creation.(SCGCQ01350844 port of CGCQ01349556)
- Page scroll doesn't work after VD creation when BG processes on VD are expanded in LSA page.(SCGCQ01351383 port of SCGCQ01349487)
- VD creation fails when a partial VD is added with decimal value & with 1MB strip size to an existing DG.(SCGCQ01354306 port of SCGCQ01348005)
- Security Key provided for importing Foreign Config is not taken by LSA.(SCGCQ01369266 port of SCGCQ01331016)
- Unexpected sense PD messages are flooded in storage log when drive is in spun dwon mode.(SCGCQ01369267 port of SCGCQ01264499)
-.(SCGCQ01375259 port of SCGCQ01373451)
- LSA: Client should not show Unlock drive option if no drives are in locked state.(SCGCQ01378557 port of SCGCQ01331121)
- LSA Server: Windows Make file check-in.(SCGCQ01384621 port of SCGCQ01384618)
- RWC3 Package: Check-in of SL-IT to the package folder.(SCGCQ01384895 port of SCGCQ01384890)
- Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01387017 port of SCGCQ01350435)
- Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389917 port of SCGCQ01389892)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01389918 port of SCGCQ01385340)
- HPE: Un-installation is not removing the folder(s) after performing the Download Diagnostics operation.(SCGCQ01389925 port of SCGCQ01385453)
- WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01391318 port of SCGCQ01389483)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01419753 port of SCGCQ01417215)
- WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ01440910 port of SCGCQ00903348)
- MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320)
- Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368)
- SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275670 port of SCGCQ01275496)
- For phys-schema.json fails for "([0, u'properties', u'isEnabled', u'enum'], 'False ...".(SCGCQ01309844 port of SCGCQ01304900)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01323613 port of SCGCQ01284395)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324865 port of SCGCQ01260226)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01338337 port of SCGCQ01331755)
- Hercules LSA : Cachecade SSD caching should be "enabled" under controller properties.(SCGCQ01339133 port of SCGCQ01337029)
- Hercules LSA : WB and AWB description in LD create page not proper.(SCGCQ01339213 port of SCGCQ01337026)
- User couldn't enter his value in seconds for locating a physical drive.(SCGCQ01344082 port of SCGCQ01332742)
- Cisco_HSW_Validation_LSA: Tooltip for "Simple Configuration" is not shown when other options displays it.(SCGCQ01347225 port of SCGCQ01346851)
- Cisco_LSA: Hyperlink symbol can be shown for "Compare and select" link in Modify Drive Group.(SCGCQ01350847 port of SCGCQ01348107)
- Cisco_HSW_Validation_LSA: Naming convention can be made same across all "Virtual Drive Erase" forms.(SCGCQ01350850 port of SCGCQ01347250)
- cosmetic changes required in "Advanced configuration" page.(SCGCQ01350851 port of SCGCQ01347253)
- DG health is not populated properly in cisco cards.(SCGCQ01350892 port of SCGCQ01349625)
- Virtual Drive Erase form is not closed when it is opened for the second time.(SCGCQ01351381 port of SCGCQ01347243)
- While adding drives to any raid group, Displaying no. of available drives and selected drives can be fine tuned.(SCGCQ01351385 port of SCGCQ01348115)
- Cisco_LSA: "Background Initialization" is misspelled in Event description & one more cosmetic change is required.(SCGCQ01351454 port of SCGCQ01348041)
- In case of FW upload, LSA crash seen with big FW version name.(SCGCQ01351457 port of SCGCQ01338340)
- LSA Client: During the exclusion of the VDs from deletion of one VD leading to the deletion of all the VDs.(SCGCQ01354432 port of SCGCQ01344115)
- WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01387009 port of SCGCQ01379795)
- Hercules:LSA:Observe that instead of "Feedback " it is named as "FeedBack ".(SCGCQ01389091 port of SCGCQ01388943)
- Updated PD firmware version is not reflecting even after LSA refresh.(SCGCQ01392422 port of SCGCQ01382013)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01393239 port of SCGCQ01385340)
- Hercules LSA: "Prepare for removal" feature should be disabled for drives in LSA.(SCGCQ01401490 port of SCGCQ01396735)
- Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834)
-.(SCGCQ01520055 port of SCGCQ01508528)
- Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674)
- Updating readme file.(SCGCQ01294583 port of SCGCQ01294570)
- For spares-schema instance validation failed for "u'foreign' is not one of [u'NATIVE', u'FOREIGN', u'MIXED']".(SCGCQ01311504 port of SCGCQ01309617)
- LSA server:LSA not showing the server reboot message after profile set.(SCGCQ01316473 port of SCGCQ01316342)
- HSW_testing_LSA : Could not initialize a VD after disabling and enabling again "Initialize" option.(SCGCQ01321339 port of SCGCQ01309783)
- Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337071 port of SCGCQ01332737)
- Cisco_HSW_Validation_LSA: Size range warning is not shown when user is giving value beyond the limit in MB unit.(SCGCQ01352603 port of SCGCQ01352603)
- LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01369283 port of SCGCQ01284395)
- RWC3 Automation Script files check-in.(SCGCQ01385008 port of SCGCQ01384997)
- LSA/RWC Automation batch files check-in.(SCGCQ01386218 port of SCGCQ01386214)
- Hercules:LSA: trying to open in new tab : "Copyright @ 2017 by Avago Technologies. All Rights Reserved" loads blank page.(SCGCQ01389089 port of SCGCQ01386140)
- Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01389588 port of SCGCQ01352480)
- SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01392429 port of SCGCQ01385340)
-.(SCGCQ01392506 port of SCGCQ01391775)
- [Lenovo 17B] - LSA- Selected Firmware version doesn't match while upgrading the FW.(SCGCQ01420040 port of SCGCQ01417199)
- Hercules:LSA: Multiple OLH links are opening when clicked on Advance configuration( IE Browser).(SCGCQ01429992 port of SCGCQ01415979)
- LSA Linux BST Automation scripts.(SCGCQ01466009 port of SCGCQ01447013)
- operations-schema.json fails for "u'percentage' is a required property..." in xSDS mode.(SCGCQ01297806 port of SCGCQ01291332)
- Hercules LSA : Auto refresh not happening on Enclosure push pull with 64 VD's configured.(SCGCQ01297821 port of SCGCQ01276760)
- SCGCQ01309545: WG: Issues pertaining to Event ID: 545: Super Cap Health event has redundant data, missing comma's.(SCGCQ01332698 port of SCGCQ01309545)
- Foreign Import page shows wrong data for the importable LD's.(SCGCQ01338335 port of SCGCQ01332912)
- Cisco Validation: FW throws an exception while scheduling Consistency check on R1.(SCGCQ01347254 port of SCGCQ01340788)
- VD size is created with improper size when user creates volume by first decreasing and increasing the size in MB unit.(SCGCQ01350833 port of SCGCQ01346860)
- WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01395078 port of SCGCQ01394281)
- Wrong API populated for enclosures operations and schema will fail.(SCGCQ01445408 port of SCGCQ01444689)
- WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01447743 port of SCGCQ01445719)
- WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01458204 port of SCGCQ01443879)
- Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114)
- MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622)
- Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336556 port of SCGCQ01313804)
- LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347125 port of SCGCQ01346904)
- Cisco_HSW_Validation_LSA: Credentials asked during login is not proper when login mode is set to 'Domain Login'.(SCGCQ01347233 port of SCGCQ01341930)
- Hercules-LSA : Updated PD firmware version is not reflecting automatically.(SCGCQ01393283 port of SCGCQ01392496)
- Hercules:LSA: Linux RHEL 6.9: View Event Logs Icon display not proper.(SCGCQ01414738 port of SCGCQ01409445)
- Hercules LSA: Reference to "drive group" while adding logical drive to existing array.(SCGCQ01444720 port of SCGCQ01444670)
- LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048)
- SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01480902 port of SCGCQ01313228)
- Fixed: Drive group Migration was disabled with NVME drives DG.(SCGCQ01313228 port of SCGCQ01289586)
- LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324864 port of SCGCQ01260226)
- Spare URI does not respond on iMR Invader.(SCGCQ01378677 port of SCGCQ01376605)
- [PA_2017B_SDV_Lenovo_x3650 M4_Storage] LSA tool update FW Image (oss: 75871) Failed for N2225 SAS HBA(Outback-2) card.(SCGCQ01408778 port of SCGCQ01408626)
- In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411632 port of SCGCQ01397546)
- Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01417213 port of SCGCQ01415347)
-.(SCGCQ01417223 port of SCGCQ01375862)
- LSA: Make operation call with query parameter.(SCGCQ01423429 port of SCGCQ01416374)
- MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01427110 port of SCGCQ01419325)
- LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340)
- LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01345397 port of SCGCQ01331755)
- Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01354345 port of SCGCQ01321474)
- Hercules LSA: Default write policy for R1 CC VD should be WB instead of WT.(SCGCQ01401352 port of SCGCQ01397557)
- [Lenovo 18A] 110340 - [PA_2017B_SDV_Lenovo_Red_Reno_Storage] Use LSA to configure M5225 and it fail to create VD's from LSA.(SCGCQ01424599 port of SCGCQ01421451)
- Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline.(SCGCQ01443687 port of SCGCQ01442554)
- Phase 2 changes for Linux VBAS automation script.(SCGCQ01460081 port of SCGCQ01455968)
- LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392)
- CSCvd28635: LSA throws inappropriate error while attempt to start patrol read on virtual drive with SSDs.(SCGCQ01319398 port of SCGCQ01284997)
- WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01332824 port of SCGCQ01325783)
- To resolve the merge conflict.(SCGCQ01348161 port of SCGCQ01348057)
- Port Info disappears on doing Drive push pull.(SCGCQ01404636 port of SCGCQ01379323)
- Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444595 port of SCGCQ01444590)
- LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401)
- LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955)


3.023.000.000 - Moderate Impact
-------------

2.085.000.000 - Moderate Impact
-------------
- Fixed issue where logs incorrect when remove/insert hdd (SCGCQ01246085)
- Fixed Invalid Server Id as part of event, if server is not in network (SCGCQ01261779)
- Fixed issue where moving PD from slot 0 to another slot, PD slot ID usually still show slot 0 and slot format (SCGCQ01264554)
- Fixed issue where external enclosure serial number in not consistent between LSA, MSM and storcli (SCGCQ01268914)
- Fixed issue where LSA does not list Raid 10 as configurable raid level under configuration service uri when drive mixing is allowed (SCGCQ01037806)
- Fixed issue where Incorrect configurable Volume sizes displayed in LSA for Raid 0(SCGCQ01039518)
- Fixed issue where LSA is not un-installing through the Uninstall-LSA option through Windows All Programs (SCGCQ01039698)
- Fixed issue where VD Properties in LSA was not getting populated for default settings (SCGCQ01043610)
- Fixed issue where controllers/{id}/spares is not populated correctly (SCGCQ01056900)
- Fixed issue where LSA displays only 2 enclosures when four enclosures are connected. (SCGCQ01061548)
- Fixed issue where Enclosure more properties displays "Number of Voltage Sensors" as "0" (SCGCQ01063504)
- Fixed issue where On Number of Temperature Sensors observe that temperature mentioned has 65535 C. (SCGCQ01063924)
- Fixed issue where When the PD is in GHS state LSA is displaying the Prepare for removal option (SCGCQ01064282)
- Fixed issue where LSA does not display the access policy 'hidden' in View Event Logs. (SCGCQ01065622)
- Fixed issue where schedule patrol -read throws an error 'Invalid URI parameter' when user clicks on Finish button. (SCGCQ01066126)
- Fixed issue where Unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01066154)
- Fixed issue where LSA crashes while trying to add a VD to the RAID 00 drive group. (SCGCQ01069405)
- Fixed issue where Simple configuration fails while trying to create VD using SSD Drive (SCGCQ01069412)
- Fixed issue where compared with MSM values of "Date of manufacture" and "Type" is varying. (SCGCQ01069493)
- Fixed issue where Unable to clear or import partial foreign configuration from LSA. (SCGCQ01069580)
- Fixed issue where Ventura: LSA still displays clear button as active even after successfully importing foreign configuration. (SCGCQ01069616)
- Fixed issue where IR3 Events logs are listed reverse sequence in "View Event logs" (SCGCQ01069847)
- Fixed issue where LSA Drive Tab PD "Unconfigured Good" count does not automatically refresh when we Move UG PD to JBOD and vice versa(SCGCQ01069852)
- Fixed issue where Modifying the VD during the VD creation results in option for user to allow more than one cachecade VD, Creation fails (SCGCQ01069898)
- Fixed issue where Instance validation fails for Clear Drive, Stop Clear Drive, Prepare & Undo prepare for removal due to "parameters":{}" (SCGCQ01070441)
- Fixed issue where Instance validation fails for Manage Power Save Settings, Controller PUT operation (SCGCQ01070690)
- Fixed issue where Instance Validation fails for Schedule Consistency Check (SCGCQ01070739)
- Fixed issue where Instance Validation fails for Physical Devices GET (IT controller) (SCGCQ01074960)
- Fixed issue where Server not found warning message is displaying repeatedly one over the other (SCGCQ01075026)
- Fixed issue where Backplane information not displayed under view server profile (SCGCQ01075841)
- Fixed issue where if config cleared during reconfiguration, progress bar does not clear(SCGCQ01075843)
- Fixed issue where hide on DG is not automatically updating the access policy of VDs (SCGCQ01076009)
- Fixed issue where LSA Crashes when we run API performance Script ususally when performing PD Operations GET in Large config (240 PD)(SCGCQ01076023)
- Fixed issue where "Controller Info" of LSA displays driver version of the Gateway server instead of displaying the driver of Vmware server (SCGCQ01076031)
- Fixed issue where "Application Version" in server profile page is displayed as "LSA Server null". (SCGCQ01076146)
- Fixed issue where there were multiple extra columns in PD tab (SCGCQ01077452)
- Fixed issue where the Physical devices are listed in Decreasing order of Device ID instead of ascending order in drive tab (SCGCQ01077563)
- Fixed issue where firmware update does not happen in the Direct agent system from Gateway (SCGCQ01077677)
- Fixed issue where Manage Power save settings with input of " 1 hour" fails with an error " Input Parameters are Invalid" (SCGCQ01078509)
- Fixed issue where Managed Server page provides option of adding gateway server from which we have already logged in to manage server (SCGCQ01078524)
- Fixed issue where Feedback is displayed as FeedBack in LSA. (SCGCQ01079092)
- Fixed issue where After adding server in Manage Server Page intermittently get a junk screen  (SCGCQ01079698)
- Fixed issue where back button does not work in case of Advanced Configuration During VD Creation (SCGCQ01079912)
- Fixed issues pertaining to "Set Patrol Read Properties" Number of PD Count allowed for patrol read (SCGCQ01080265)
- Fixed issue where after logging out from server that is been managed. Clicking Server again in managed server page LSA asks for credentials (SCGCQ01080448)
- Fixed issue where Instance Validation fails for PROGRESS related Operations (SCGCQ01082194)
- Fixed issue where Instance validation fails for "/controllers/0/operations/security" URI : Controller Operation POST (SCGCQ01082618)
- Fixed issue where inappropriate error message is displayed in LSA on flashing fw on IT Intruder (SCGCQ01082897)
- Fixed issue where LSA page does not automatically refresh when PD moved from UG bad to UG Good SS page, CC page does not give option (SCGCQ01083060)
- Fixed issue where on clicking save button on mail server page its shift to Alert Settings without saving that page. (SCGCQ01083063)
- Fixed issue where LSA does not show the default power save mode time set in mfc (SCGCQ01083106)
- Fixed issue where after adding server the managed server list, then logging out, new server cannot be logged into. (SCGCQ01083226)
- Fixed issue where LSA service is not present in the Windows services after downgrading LSA. (SCGCQ01084774)
- Fixed issue where Event Response is giving Default Write Policy: abc (SCGCQ01043609)
- Fixed issue where Sending Invalid HTTP verb in the request for an URI fails with 404 instead of 405 (SCGCQ01059216)
- Fixed issue where texts linked to the health icons "optimal", "critical", "needs attention", in server summary page Should be clickable (SCGCQ01063432)
- Fixed issue where LSA still displays physical disk actions and properties menu when no pd is selected after sorting from Enclosure/slot. (SCGCQ01063524)
- Fixed issue where Instance Validation fails for Simple Configuration POST (SCGCQ01064737)
- Fixed issue where consistency check Schedule parameters is available even after selecting the "Disable" from the Consistency check mode (SCGCQ01069825)
- Fixed issue where LSA not accessible through Chrome browser Version 48.0.2564.109 m (SCGCQ01078618)
- Fixed issue where while initiate ISE against 3rd party locked UG drive, XHR_Header code says "POST 200" but XHR_Response says "Er 77" (SCGCQ01080402)
- Fixed inconsistency between the VD properties displayed in STORCLI when compared with other Apps. (SCGCQ01081145)
- Fixed issue where LSA doesn't get updated without a service restart on Vmware server with IR3 controller. (SCGCQ01081324)
- Fixed issue where matching error description is not shown by client when there is a session already active during login. (SCGCQ01063542)
- Fixed issue where LSA login attempt failed for Vmware Server (SCGCQ01064784)
- Fixed issue where 002.010.000.000 build (Gateway & Standalone) is unable to discover server (SCGCQ01069396)
- Fixed issue where replace drive table does not have device Id column (SCGCQ01075112)
- Fixed issue where LSA does not update the data automatically when Delete VD is performed. (SCGCQ01079635)
- Fixed issue where RWC3-LWM (Windows) is unable to send mail to SMTP (SCGCQ01173361)
- Fixed issue where Ventura IT drive push and pull needs services restart to update the count (SCGCQ01066048, Port of SCGCQ01064904)
- Fixed issue where LSA Allows JBOD Drive having OS to be converted to UG drive, doesnt notify the user on the OS present on JBOD (SCGCQ01067253, Port of SCGCQ01052412)
- Fixed issue where LSA displays "error:Not all values are set successfully" while trying to save power save settings on IMR Ventura. (SCGCQ01067711, Port of SCGCQ01057457)
- Fixed issue where LSA shows blank screen after log in with mutiple controller in the setup (SCGCQ01069360, Port of SCGCQ01068813)
- Fixed issue where intermittent update Ventura firmware hang using LSA ( StorCLI is OK ) (SCGCQ01069565, Port of SCGCQ01038421)
- Fixed issue where user unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01070807, Port of SCGCQ01066154)
- Fixed issue where all the events are not getting downloaded while downloading log from LSA (SCGCQ01145261, Port of SCGCQ01139334)
- Fixed issue where no error message is displayed while importing secure EPD through wrong key (SCGCQ01066088, Port of SCGCQ01063911)
- Fixed issue where user unable to clear or import partial foreign configuration from LSA. (SCGCQ01085466, Port of SCGCQ01069580) 

2.030.000.000 - New Function Only/No fixes
-------------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2022 Lenovo. All rights reserved

StorCLI command line tool (For Linux)



StorCLI (Command Line) Utility for Storage Management

Adapters Supported:
	ThinkSystem 430-8i SAS/SATA 12Gb HBA for 7Y37A01088
	ThinkSystem 430-16i SAS/SATA 12Gb HBA for 7Y37A01089
	ThinkSystem 430-8e SAS/SATA 12Gb HBA  for 7Y37A01090
	ThinkSystem 430-16e SAS/SATA 12Gb HBA for 7Y37A01091
	ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA  (NA-StarkSASHBA)
	ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA for 4Y37A09724
	ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA for 4Y37A09725


NOTE TO SERVICE - Reference RETAIN #N/A
007.2008.0000.0000 - Moderate Impact/Low Probability of Occurrence
--------------------
MR 7.20

Defects:
-Storcli : Copyright shows as year 2021 instead of 2022 & also build release year 2021 instead of 2022 & also build release year shows as 2021 instead of 2022.(DCSG01124638)
-Error seen while flashing psoc.rom in efi CLI.(DCSG01131584)
-storcli 7.2001 does not return values for a bad drive.(DCSG01052072)
-Spellling of mismatch is displayed as "Missmatch" in "Encryption type missmatch" error message..(DCSG01091937)
-Device Type for Backplane in Alilog shown as Enclosure.(DCSG01109911)
-Storcli shows Protection Information (PI) capable drive i.e. "PI eligible" as No, however LSA shows it properly.(DCSG01145223)
-CLI not iterating through MR_SAS_CONNECTORS for H750 controllers.(DCSG01077564)
-Instance validation fails for "/c0 show all" and "controller-detailed-properties-schema.json".(DCSG01035798)
-OS drive name shown as N/A for multiple VDs.(DCSG01101813)
-Storclif reports BBU instead of cachevault for failed retention tests.(DCSG01092227)
-Storclif 7.2005 can't start retention test, says No CacheVault Found!.(DCSG01130532)
-Enclosure logical ID field is not displayed for BP connected to connected to Boca 540-16i controller.(DCSG01024654 (Port Of Defect DCSG01024693))
-Set Patrolread command hangs while setting "excludevd".(DCSG01101780 (Port Of Defect DCSG01102890))
-Strocli.efi utility got hung on issuing "storcli /c0 show" command.(DCSG01049757 (Port Of Defect DCSG01050540))
-"storcli /call show" shows jumbled drives in a Multi IT controller environment.(DCSG01040245 (Port Of Defect DCSG01040583))
-PD size displayed in Gib for some of the 4K drives is incorrect..(DCSG00389591 (Port Of Defect DCSG00994728))
-PD Firmware Release Number = N/A is displayed for drive which has valid Firmware Release Number.(DCSG01083763 (Port Of Defect DCSG01083800))
-Storcli shows success without proper description for "VD delete BBMT" command when no VD present..(DCSG01002466 (Port Of Defect DCSG01024694))
-Update splitpackage script for shenandoah.(DCSG00651204 (Port Of Defect DCSG00994744))
-While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883 (Port Of Defect DCSG01036901))
-While trying to import foreign config, Storcli is not showing drive as "Hotspare" if the user has only hot spares.(DCSG01028926 (Port Of Defect DCSG01029835))

EnhancementRequests:
-Update ControllerInfo Structure with PartNumber - API Changes.(DCSG01064529)
-Request for Win2022 Supportnfor their 16G Enablement launch, March 2022 RTS.(DCSG00977684)
-MegaRAID key management feature: volatile key escrow.(DCSG00992844)
-secureSignBin: implement feature to download the public key during signing or with explicit arg.(DCSG01035866)
-DCSG01082488
-API change to support PD sanitize operations enhancements.(DCSG01070995)
-Aero 9560/9580 - Add PSOC6 as Vision Controller.(DCSG01056506)
-Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API.(DCSG01065378)
-Change the attribute name "Secured" to "Locked" in PD Properties output.(DCSG01040562 (Port Of EnhancementRequest DCSG01040785))
-Handling of VD target-ID's individually even when target-ID is assigned beyond maxLDs.(DCSG01091990 (Port Of EnhancementRequest DCSG01092477))
-Windows Client Win11 OS Support.(DCSG01043616 (Port Of EnhancementRequest DCSG01068906))


007.1907.0000.0000 - Moderate Impact/Low Probability of Occurrence
--------------------
MR 7.19

Defects:
-While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883)

007.1707.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.17

Defects:
-StorCLI listing failed NVMe drives in non-sorted order.(DCSG00320844
-Instance Validation Failed for "/call/fall show all.json" and foreign-configuration-detailed-schema.json.(DCSG00408509
-MR7.16_storcli: VD creation with the remaining drives fails.(DCSG00303606
-Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693
-Package Version is not displayed properly after flashing firmware..(DCSG00961822
-PH18 BETA - StorCLI - Update YEAR in the CLI banner.(DCSG00707142
-Storcli launch fails with permission denied message.(DCSG00972016
-Setting CC date and time exceeding the limit, needs to be handled.(DCSG00520110
-"rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337710
-Storcli lists "/ex show all" for "/cx show all" command..(DCSG00417504
-DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00359247
-Storcli: learnStartTime displayed incorrectly in command details.(DCSG00320649
-Storcli /cx set debug reset all help description needs an update.(DCSG00521571
-storcli /cx set flushwriteverify help needs an update.(DCSG00507067
-PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00315152
-PH18 PA - StorCLI - appropriate message needed for erase all excludemfg command.(DCSG00395234
-Storcli shows "success" with incorrect message INSTEAD of syntax error for "/c0/d1 set" command..(DCSG00543505
-storcli show alilog shows "SATA-3G" as device interface for 9361-16i.(DCSG00555672
-Handling PBLP component whild displaying Image component versions.(DCSG00301878
-MR_7.17: After Driver unload/load via DDV tools- Ctrl acces via Storcli exit with Segmentation Fault.(DCSG00426317
-coverity: fixing non-array delete and dereferencing before NULL checks.(DCSG00368376
-Handling the read-only file system from storcli.(DCSG00542683
-Updating new SPDM MPI errors.(DCSG00435039
-"Failed Drive not found" reported from enclosure level show repair command.(DCSG00423496
-Controller Lane show command is not working with individual Lanes.(DCSG00386181
-Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00469639
-VD creation fails from storcli even though free capacity is present in DG.(DCSG00757768
-Aero 7.15 CLI shows a extra space in the /c0 set cc h command.(DCSG00298943
-Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00408497
-show alilog command displays JBOD as volumes.(DCSG00556934
-Instance Validation Failed for "/call/fall import preview.json" and foreign-configuration-detailed-schema.json.(DCSG00408512
-Max commands for averaging needs to be removed from DPMstat RA output.(DCSG00286349 (Port Of Defect DCSG00306711)
-Failure observed while running set sbr command.(DCSG00779151 (Port Of Defect DCSG00932922)
-Storcli "/call/eall/sall download status" error message needs correction..(DCSG00735452 (Port Of Defect DCSG00757676)
-Unified StorCLI MR7.15 - Fixing coverity issues - Part 1.(DCSG00290662 (Port Of Defect DCSG00368612)
-Atlas 4.2: StorCLI lists wrong error message "Failed in standard Inquiry", when user tries to upgrade/downgrade all connected NVMe Drives FW at a time.(DCSG00309398 (Port Of Defect DCSG00313432)
-The foreign config of DHS/GHS details is not listing under foreign config import preview.(DCSG00919659 (Port Of Defect DCSG00935761)
-Invalid Array Size in ZB is displayed for Degraded R1 span Foreign VD in storcli foreign import preview.(DCSG00916209 (Port Of Defect DCSG00935751)
-Logical ID of Cobra expander not displayed properly in Storcli and LSA.(DCSG00342456 (Port Of Defect DCSG00391477)
-CLI crashes when issuing the phyerrorcounters command on a 14G Expander backplane.(DCSG00323054 (Port Of Defect DCSG00323721)
-Show command status not proper when issued with wrong EID.(DCSG00906544 (Port Of Defect DCSG00935762)
-Storcli shows no output for valid parameter for "/c0/p0,1,22 show" command..(DCSG00840944 (Port Of Defect DCSG00932927)
-From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494 (Port Of Defect DCSG00391509)
-Non Foreign drives GHS are listing under Foreign import preview.(DCSG00931210 (Port Of Defect DCSG00935765)
-Storcli "show file" command does not report correct FW version.(DCSG00299788 (Port Of Defect DCSG00302030)
-Storcli show incorrect property name for "/c0/d0,3 set hidden=off" command..(DCSG00733214 (Port Of Defect DCSG00758467)
-Coverity fixing bad allocator and resource leaks.(DCSG00307346 (Port Of Defect DCSG00307355)
-Vses Device Type is displayed as Enclosure for IT card.(DCSG00920244 (Port Of Defect DCSG00935772)
-StorCLIF fail to flash firmware image of BTBL (BOOT_BLOCK) on Invader MR.(DCSG00330381 (Port Of Defect DCSG00353198)
-Storcli throws junk value is shown on set consistency check.(DCSG00906989 (Port Of Defect DCSG00935693)
-MR 7.15 StorCLI : Addressing Coverity defects.(DCSG00286677 (Port Of Defect DCSG00311222)
-CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802 (Port Of Defect DCSG00935973)
-VDs imported from Jbod mode to RAID do not have OS name available in Linux OS.(DCSG00968023 (Port Of Defect DCSG00975216)
-CLI failing to stop a BGI or CC when paused..(DCSG00735544 (Port Of Defect DCSG00757870)
-Enclosure phyerrorcounters fails in VMware platform.(DCSG00706496 (Port Of Defect DCSG00706497)
-Storcli shows success for "set patrolread excludevd" command failure in the presence of VD..(DCSG00906735 (Port Of Defect DCSG00935770)
-For empty SPDM slots 0 & 1 show security slot info command shows as Invalid data on IT controller..(DCSG00348125 (Port Of Defect DCSG00353186)
-Segmentation fault noted with drive firmware update.(DCSG00758645 (Port Of Defect DCSG00932904)
-VD creation output shows VD size as 0KB when it reaches maximum supported virtual disks(64VDs) in a DG..(DCSG00349415 (Port Of Defect DCSG00353914)
-SAS drive Inquiry data is not shown in drive show all output.(DCSG00778367 (Port Of Defect DCSG00932917)
-Fixing Coverity defects of MR 7.15.(DCSG00299981 (Port Of Defect DCSG00309219)
-Post reboot incorrect lane speed is displayed in Storcli when user sets it to 16GT/s.(DCSG00383336 (Port Of Defect DCSG00395901)
-On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266888)
-Coverity defects - remove resource leaks, invalid types in function arguments.(DCSG00269017 (Port Of Defect DCSG00277861)
-Storcli will not show LargeIOsupport is enabled/disabled on the controller.(DCSG00353195 (Port Of Defect DCSG00353882)
-Storcli shows target id of the drive as boot drive instead of showing drive slot number for JBOD drives..(DCSG00344079 (Port Of Defect DCSG00353203)
-MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282590)
-Removed leading spaces for SATA drives.(DCSG00904104 (Port Of Defect DCSG00935692)
-Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266881)
-Size of Degraded R10 Foreign VD is displayed as 0 KB in storcli.(DCSG00916207 (Port Of Defect DCSG00935746)

EnhancementRequest:
-Adding new License file and updating the build script to include the new file.(DCSG00324401
-Add CLI command to control Parity Read Cahce Bypass for SSD VDs.(DCSG00342282
-MR7.16 : Support WJ Pinning for both WB and WT Parity RAID VDs.(DCSG00214472
-Provide option in storcli to disable / enable the Preboot trace Buffer feature in MR FW..(DCSG00310366
-Enable cache retention testing on Shenandoah controllers for factory testing.(DCSG00340899
-Updating storcli code and makefiles to support VBAS builds on GCP.(DCSG00412063
-Additional NameSpace behavior changes.(DCSG00310386
-Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976
-StorCLI: Automate the test cases specific to MR7.17 Product Requirements.(DCSG00433350
-Add support for reporting SPDM Measurement Specification and Hash Algorithm.(DCSG00301782
-Updating command legends as per the command output.(DCSG00083851
-IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00371061
-MR7.16: StorCLI does not show the SAS Address of the enclosure.(DCSG00255109
-Unified StorCLI 7.17 - x64 UEFI VBAS / GCP support.(DCSG00559813
-Updating Error Strings for NVME init error codes in Apps.(DCSG00434066
-MR7.16 StorCLI: Ruby SED Support.(DCSG00264744
-CLI to handle ERROR_BUSY from Windows storport.(DCSG00348813 (Port Of EnhancementRequest DCSG00353214)
-Displaying "OS name" for VDs imported from EHBA mode to RAID.(DCSG00775114 (Port Of EnhancementRequest DCSG00932911)
-Display Enclosure serial No in Storcli.(DCSG00500922 (Port Of EnhancementRequest DCSG00932906)
-Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00500924 (Port Of EnhancementRequest DCSG00521828)
-SEKM Support in CLI.(DCSG00433143 (Port Of EnhancementRequest DCSG00935780)
-CLI: Package Stamping Verification During Firmware Update.(DCSG00239672 (Port Of EnhancementRequest DCSG00282815)
-StorCLI has the ability to switch the OOB mode.(DCSG00547179 (Port Of EnhancementRequest DCSG00935783)
-SMART Polling Improvement - PERC 10.(DCSG00249963 (Port Of EnhancementRequest DCSG00282814)
-PERCcli turn off logging by default.(DCSG00255367 (Port Of EnhancementRequest DCSG00282813)
-Remove the MFG date, Revision date and Rev from IT StorCLI output.(DCSG00415059 (Port Of EnhancementRequest DCSG00418372)
-Display port information for NVMe Init failed drives.(DCSG00359418 (Port Of EnhancementRequest DCSG00421187)
-storcli "set good" command can still be used for JBOD EPD-PT drives.(DCSG00318591 (Port Of EnhancementRequest DCSG00353919)
-PERC11.1 - Dual x8 Support for 16 port Controllers.(DCSG00299060 (Port Of EnhancementRequest DCSG00323772)


007.1513.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.15

Defects:
-CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802)
-Handling the read-only file system from storcli.(DCSG00938327 (Port Of Defect DCSG00542683))

Enhancements:
-Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00930193 (Port Of EnhancementRequest DCSG00500924))

007.1510.0000.0000  - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.15

Defects:
-From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494)
-PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00320641 (Port Of Defect DCSG00315152))
-StorCLI listing failed NVMe drives in non-sorted order.(DCSG00321815 (Port Of Defect DCSG00320844)
-MR 7.16: Storcli: learnStartTime displayed incorrectly in command details.(DCSG00321908 (Port Of Defect DCSG00320649))
-rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337735 (Port Of Defect DCSG00337710))
-DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00360517 (Port Of Defect DCSG00359247))
-Controller Lane show command is not working with individual Lanes.(DCSG00386184 (Port Of Defect DCSG00386181))
-storcli /cx set flushwriteverify help needs an update.(DCSG00541982 (Port Of Defect DCSG00507067))
-"Failed Drive not found" reported from enclosure level show repair command.(DCSG00430578 (Port Of Defect DCSG00423496))
-Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00489855 (Port Of Defect DCSG00469639))
-Storcli /cx set debug reset all help description needs an update.(DCSG00538790 (Port Of Defect DCSG00521571))

EnhancementRequest:
-Display Enclosure serial No in Storcli.(DCSG00500922)
-IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00405900 (Port Of EnhancementRequest DCSG00371061))


007.1326.0000.0000  - Moderate Impact/Low Probability of Occurrence
-------------------- 
Defects:
-Foreign Config Preview shows empty data when Foreign config is present with Rebuild is in Progress.(DCSG00261203)
-Inconsist DG number in StorCLI.(DCSG00235157)
-RTTdump shows success but it fails to download the dump..(DCSG00253652 (Port Of Defect DCSG00253719))
-Incorrect Adapter type shown in the perccli show all output.(DCSG00241405 (Port Of Defect DCSG00244145))
-Expander firmware download using with mode 5 option fail with error message..(DCSG00239524 (Port Of Defect DCSG00240685))
-With length command, CLI says Memory Exhausted.(DCSG00235628 (Port Of Defect DCSG00236791))
-Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 (Port Of Defect DCSG00286701))
-Observe CLI Crash on windows while setting Autoconfig option.(DCSG00253642 (Port Of Defect DCSG00253722))
-MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282592))
-"No Controller found" shown when controller is busy..(DCSG00248017 (Port Of Defect DCSG00253661))
-On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266886))
-Connector Name is incorrectly displayed when connector count goes beyond 8.(DCSG00249023 (Port Of Defect DCSG00252701))
-MR 7.15: Storcli: Instance Validation Failed for "virtual-drive-config-schema.json" and "/call delete config force".(DCSG00247992 (Port Of Defect DCSG00253761))
-With new MR API changes, storcli shows failure while changing accesspolicy.(DCSG00257307 (Port Of Defect DCSG00258140))
-MR 7.15: Storcli: Instance Validation Failed for "enclosure-fw-download-schema.json" and "enclosure FW download" output..(DCSG00250066 (Port Of Defect DCSG00253733))
-Show expansion shows wrong output in presence of JBODs..(DCSG00247163 (Port Of Defect DCSG00252417))
-Enclosure position value not listed properly in show all command.(DCSG00254935 (Port Of Defect DCSG00256384))
-Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266894))
-Expander firmware download help need to be corrected for IT controller..(DCSG00239870 (Port Of Defect DCSG00240680))

EnhancementRequests:
-To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h.(DCSG00256271)
-Additional FDE type for Ruby SED support.(DCSG00055878)
-MFI SMP Port Num API changes.(DCSG00257777)
-MR7 API: Add package incompatibility reporting.(DCSG00231443)
-SMART Polling Improvement - API Changes.(DCSG00246317)
-Implement customSign.exe CLI wrapper utility to help customers sign with their private key.(DCSG00234646)
-Changes to support 16port connection to Expander with AeroIOC.(DCSG00254845)
-Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 (Port Of EnhancementRequest DCSG00290359))

007.1325.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------  
MR 7.13
Fix issue:
DCSG00235157 - Inconsist DG number in StorCLI
Description:
Customer reported the DG/Array/Row is incorrect to get from storcli and it causes "insert" command failure. 

007.1324.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------  
MR 7.13
Defects:
-Storcli: Optl not mentioned in /call/dall show output..(DCSG00065740)
-Instance Validation Failed for "/call set smartpollinterval=300" and controller-smartpollinterval-schema.(DCSG00057141)
-StorCLI crash when create VD.(DCSG00052275)
-/e: and /s: is not mentioned in the Convention for /storcli64 /c0/v0 start migrate detailed ?.(DCSG00143788)
-BZ(186687):[AMD2P & Whitley] EXSi 7 can't boot up after install storcli.(DCSG00048516)
-Storcli show Device type as backplane while no drives are connected.(DCSG00074732)
-Help Description for Migrate shows "operation" printed twice in Storcli output..(DCSG00063696)
-Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00057213)
-Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements - Part 1.(DCSG00046195)
-Foreign topology table display BT as "Y" for drives which are in foreign state..(DCSG00068453)
-Storcli: Same help description across "/c0/e0 show" and "/c0/e0 show all"..(DCSG00064748)
-While executing perccli, by default log file with storcli.log is getting generated..(DCSG00038031)
-MR 7.13: Storcli(Regression): Syntax error seen while using "nolog" and "page" together as parameters.(DCSG00071417)
-In Aero behind atlas configuration "NVME" drive firmware revision shows wrong.(DCSG00049614)
-Storclif command for battery retention test issues command to start retention test which is an unsupported command.(DCSG00058688)
-Show DPM with type LCT is not giving proper output and register DPM commands for all OS.(DCSG00033459)
-Storcli: ProdID Legend abbreviation missing in /c0/eall show output..(DCSG00063317)
-FW sometimes allows an invalid CLI command (set personality=HBA) to be successful and sets the personality to eHBA mode.(DCSG00129542)
-Fixing Coverity defects.(DCSG00044004)
-Unable to create JBOD using the legacy command with latest Perccli.(DCSG00118670)
-MR 7.13: Storcli: GHS is shown as revertible.(DCSG00065815)
-In the presence of Locked Foreign config, "/c0/fall del" shows incorrect output..(DCSG00062615)
-StorCLI - '/c0 show nolog' reported as Un-supported Command.(DCSG00071410)
-Set VD policy to WB (unsupported )should return failure in JBOD personality..(DCSG00076992)
-Shenandoah_MRSA: Enclosure Bay count coming Wrong in CLI.(DCSG00074731)
-Shenandoah_Storcli : Legend for ID in JBOD list is missing.(DCSG00069312)
-Incorrect Legend abbreviation in storcli show output.(DCSG00058874)
-MR 7.13: Storcli: controller add commands are listed along with vx commands..(DCSG00065744)
-Even on giving wrong 'storclif delete config' command syntax, the config is cleared successfully without any error.(DCSG00055164)
-Storcli.efi shows incorrect note for unsupported commands for MR controllers.(DCSG00056335)
-VMware peccli, percli64 and storcli64 bit binary loads library from storcli 32 bit's installation path.(DCSG00074600)
-StorCLI - /c0/eall/sall start locate not working for second enclosure connected.(DCSG00040244)
-Instance Validation Failed for "/call show dpm" and controller-dpm-schema.json.(DCSG00057194)
-Command description should be modified for storclif /cx set activityforlocate=.(DCSG00069746)
-MR 7.13: Storcli: bbu not described in convention details.(DCSG00066314)
-Shenandoah_storCLI: Add vd command for r0 getting successful with 512KB when mazStripeSize is 1MB.(DCSG00057003)
-Fixing Coverity defects, uninitialized, unused variables and memory leaks.(DCSG00052049)
-Start_entry is not a command parameter in show events command.(DCSG00067937)
-On OS /cx/dall split mirror command shows success when there is no drive groups.(DCSG00069690)
-Update the storcli readme with for Esxi 6.x and Esxi 7.0 releases.(DCSG00055533)
-Extended the abbreviation in the legends.(DCSG00069703)
-Shenandoah : storcli : Energy Pack show present for MR 216i controller , where the hardware is not supported.(DCSG00053888)
-"set sbr" command mentioned in detailed help but not listed in help output..(DCSG00068444)
-Creation of VD for with more than 64 drives is failing with "Cannot create configuration with x drives".(DCSG00056544)
-Description of compare firmware ver command does not mention as IT supported command.(DCSG00070258)
-Command description should be modified for /cx set alarm command.(DCSG00069709)
-MR 7.13 : RSOD is seen for storcli.efi show command when the controller is in invalid state.(DCSG00066879)
-StorCLI /cx restart is not supported in UEFI environment should be mentioned in help..(DCSG00068879)
-Remove deprecated command 'show adpcount' from Ubuntu folder(readme).(DCSG00058329)
-Segmentation fault seen while running OCR and Patrol read in loop on ESXi7.0 OS..(DCSG00066854)
-Instance Validation Failed for "/call/fall import preview" and foreign-configuration-detailed-schema.json.(DCSG00068868)
-Field for CV is missing in table as well as in legend for storcli64.exe show command.(DCSG00067075)
-Restrict discovery of PERC HBA through StorCLI(Static binary).(DCSG00077037)
-PH14 Alpha Aero - StorCLI - Difference in output noted for /cx/px set state command.(DCSG00055119)
-MR 7.13 : Enclosure Device ID is mentioned in the legend for /cx/vall show command.(DCSG00067878)
-MR 7.13 : Cosmetic issue is seen in the command name of /cx /cx show memscrubpatterns ?.(DCSG00067877)
-Commands displayed twice in help description..(DCSG00068441)
-Storcli DPM does not use legend "Resp" in EXT output.(DCSG00060706)
-Enclosure ID is not mentioned as optional in "add Vd " command.(DCSG00058867)
-Port information coming as internal and Location as Blank in when all the drives are removed from UBM2 Backplane.(DCSG00071756)
-DPM delete help is listed under drive delete command group.(DCSG00053537)
-No mention on convention in restart command description..(DCSG00068542)
-Fixing Coverity defects - Uninitialized variable, resource leaks and null referencing.(DCSG00041202)
-Set the PR to run on only configured array, but it complete the PR along with un-configured area..(DCSG00067103)
-Fixing Coverity issues - Resource leaks.(DCSG00054690)
-Storcli throws incorrect error message for /c0 add vd each r0 when Ubad drive is present in the setup..(DCSG00069698)
-Use NVRAM to save PTB information -- API changes.(DCSG00082981)
-Debug logs in FreeBSD is logging timestamp in different lines.(DCSG00069730)
-"/c0 show nolog" shows as "un-supported command.(DCSG00068482)
-Shenandoah_Storcli : The status of PD FW update on multiple drives is not proper when parallel is not included.(DCSG00069693)
-Device type of UBM backplane is displayed as expander in Valvano-32i Controller managed port(C3)..(DCSG00054275)
-Shenandoah_PA2:StorCLI not branding compliant for VD creation command Failure case -IO Policy specif.(DCSG00049610)
-Storcli: px is not described in convention details..(DCSG00065742)
-Unmap enabled not listed for unmap enabled VDs with /cx/vall show all cli command.(DCSG00112331)
-Instance Validation Failed for "storcli64.exe show" and system-schema.json.(DCSG00057156)
-Not able to create R1/R10 with 1MB size and strip size is 1MB.(DCSG00058162)
-Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00063626)
-StorCLI not reporting default oob settings from nvdata value.(DCSG00066530)
-Executing storcli commands from external path throws error.(DCSG00072117)
-StorCLI: /storcli /cx add vd verbose help ,strip size 512 is missing in help description under strip sizes..(DCSG00146343)
-MR 7.13: Storcli: Caution mentioned instead of note..(DCSG00066554)
-perccli is Reporting incorrect scheduled BBU Learn Date.(DCSG00109638)
-Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements.(DCSG00046460)
-Storcli64.exe /c0 show freespace shows unnecessary data when freespace is not present.(DCSG00055686)
-Schema mapping list is not updated with DPM commands.(DCSG00057823)
-Foreign DHS drive state is displayed as UGood under /c1/fall show all tab..(DCSG00068427)
-MR 7.13: Storcli: logfile is not described in show dpmstat command..(DCSG00065838)
-Statistics is spelled as Statitics in dpm stat commands.(DCSG00057112)
-Cache Vault should be placed instead of battery for "storcli /cx/cv show status ?" help.(DCSG00143868)
-Exit code showing "0" for failed storCLI command due to syntax error.(DCSG00054313)
-Removal of log type from storcli logs.(DCSG00046794)
-Discription for the term "NoVDs" is missing in the legends.(DCSG00068592)
-start dpm returned error.(DCSG00035436)
-Storcli: Show latest events output print shows 0.00 for all the number of events dumped (expected is the number of events queried for).(DCSG00068877)
-Incorrect message noted when Ventura firmware flashed on Aero board.(DCSG00046031)
-No consistency in the help details of "/c0/ex download" commands.(DCSG00064745)
-Storcli license file is not present in the Vmware, Ubuntu & EFI folders.(DCSG00056538)
-Storcli issuing 'add vd r0 drives=all' causes storcli to crash.(DCSG00053963)
-No syntax error for multiple usage of "nolog" parameter in the command..(DCSG00066729)
-Re-Host information is blank when ASO is not enabled.(DCSG00072628)
-SSD Wear guage Parameter "SSD Percent used" to be removed from CLI.(DCSG00074791)
-MR 7.13: Storcli: sx not described in convention details..(DCSG00066310)
-Error message is improper for invalid raid level in volume creation.(DCSG00081057 (Port Of Defect DCSG00083789))
-Set MFG command does not throw an error when executed with empty file..(DCSG00074178 (Port Of Defect DCSG00074209))
-VD delete command works with multiple force options.(DCSG00165527 (Port Of Defect DCSG00167329))
-Syntax error for /c0 show AliLog ?.(DCSG00109790 (Port Of Defect DCSG00112470))
-storcli faults when issue drive poh command on Linux.(DCSG00075870 (Port Of Defect DCSG00075875))
-show memscrubpatterns shows status as success but failed in the description.(DCSG00077082 (Port Of Defect DCSG00103214))
-PH15 PA StorCLI - Segmentation fault observed when Sea IT PSOC image flashed on Ventura.(DCSG00075626 (Port Of Defect DCSG00212680))
-Wrong enclosure details are displayed when slot details are queried..(DCSG00127133 (Port Of Defect DCSG00139981))
-Storcli_VMWare gives failure messages when user tries to set the lanespeed.(DCSG00167210 (Port Of Defect DCSG00167280))
-"Download cpld" command displays incorrect output for MR controller..(DCSG00075734 (Port Of Defect DCSG00075863))
-The properties displayed in the command show htbparams has misspelled fields.(DCSG00104056 (Port Of Defect DCSG00105681))
-Instance Validation Failed for "/call/fall show" and foreign-configuration-schema.json.(DCSG00076415 (Port Of Defect DCSG00078173))
-storclif.exe /cx set copyback ? shows incorrect command name..(DCSG00075718 (Port Of Defect DCSG00075890))
-No description mentioned for "/cx set eghs" command..(DCSG00074290 (Port Of Defect DCSG00074768))
-Unified StorCLI Phase 15: storcli64 /cx add vd each help file missing options and format inconsistencies.(DCSG00139659 (Port Of Defect DCSG00139995))
-Aero Controller DPM does not report Max Response Time under 1 ms..(DCSG00099365 (Port Of Defect DCSG00102548))
-Storcli: Wrcache is mentioned instead of WT| WB.(DCSG00074284 (Port Of Defect DCSG00074767))
-Storclif allows to set Set SubOEMID as 1000 and more.(DCSG00079932 (Port Of Defect DCSG00080836))
-Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00031711 (Port Of Defect DCSG00063602))
-Storcli /cx show cc , does not shows the "Unit" for CC execution Delay..(DCSG00126229 (Port Of Defect DCSG00129753))
-storcli64.exe /c0/e1/s1 start sanitize throws syntax error..(DCSG00129738 (Port Of Defect DCSG00129750))
-forcehcb is executed with incorrect description in OS level..(DCSG00080961 (Port Of Defect DCSG00083295))
-"Show alilog" command output shows invalid PD ID in Virtual drive info..(DCSG00167354 (Port Of Defect DCSG00167449)
-force is not defined under OPTIONS in storcli64 secureerase help file.(DCSG00148255 (Port Of Defect DCSG00150480))
-Storcli displays "Returned SCSI status for the command : Check condition" along with regular command.(DCSG00138580 (Port Of Defect DCSG00139200)
-Aero Alpha: Storcli stops functioning during run of attached script.(DCSG00034379 (Port Of Defect DCSG00039682)
-/vx is mentioned in the convention for storclif64.exe /cx set cc detailed ?.(DCSG00075700 (Port Of Defect DCSG00075894))
-DCSG00096587.(DCSG00104055 (Port Of Defect DCSG00108742))
-Avenger: ./storcli2 /c0 show ds all command(not present) shows the output of /c0 show all.(DCSG00061163 (Port Of Defect DCSG00080485)
-PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup.(DCSG00050891 (Port Of Defect DCSG00079275))
-Storcli output starts with "GetCtrlInfo : ProcessLibCommand failed; retCode = 0xFF" for all command.(DCSG00214170 (Port Of Defect DCSG00214248))
-"OS Drive Name" does not display the details in "vall show all" for esxi OS.(DCSG00102559 (Port Of Defect DCSG00103190))
-Storcli: "show bbmt" displays output for an invalid VD..(DCSG00228667 (Port Of Defect DCSG00230346))
-Storcli command description shows none for Download firmware failure.(DCSG00221431 (Port Of Defect DCSG00223281))
-Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json.(DCSG00132488 (Port Of Defect DCSG00137828))
-NoVDs is displayed in dall show output..(DCSG00074628 (Port Of Defect DCSG00074763))
-"reset errorcounters" command mentions options under conventions.(DCSG00074288 (Port Of Defect DCSG00074764))
-PH16 PA - StorCLI - Compare fwprodid help page needs to be updated.(DCSG00167732 (Port Of Defect DCSG00215133))
-Display basic secure boot details for Sea IT controller.(DCSG00074184 (Port Of Defect DCSG00074218))
-No consistency in the description of Force option.(DCSG00074283 (Port Of Defect DCSG00074765))
-Storcli /c0/eall show status extended command fails to generate any output for ARM server backpla.(DCSG00146359 (Port Of Defect DCSG00150479))
-Debug log configuration file for perccli is taking storcliconf.ini.(DCSG00074691 (Port Of Defect DCSG00074757))
-Compare fwprodid command fails for 9500-16i.(DCSG00092943 (Port Of Defect DCSG00115266))
-Handling of controller properties related to drive FW download.(DCSG00138192 (Port Of Defect DCSG00139266))
-In command storcli /cx/ex/sx show DPM type=Ext , Sectors Read (Written) is not displayed correctly.(DCSG00083167 (Port Of Defect DCSG00103210))
-Ph16 PA: Storcli crash observed while running show all with NVMe drives connected.(DCSG00150686 (Port Of Defect DCSG00167881))
-Description for "profileid=" is missing in help and detailed help.(DCSG00152251 (Port Of Defect DCSG00152935))
-EKMS Boot Agent Status is not updating properly..(DCSG00049004 (Port Of Defect DCSG00050289))
-MR 7.15: Storcli: Force option is mentioned as "For".(DCSG00223195 (Port Of Defect DCSG00225259))
-Storcli displays 255 max spin-up drive count in help description instead of 240.(DCSG00098081 (Port Of Defect DCSG00108741))
-"Compare factorysettings" command displays incorrect output for wrong input file.(DCSG00075762 (Port Of Defect DCSG00075888))
-Storcli64 /cx show spinupdrivecount help file description needs update.(DCSG00150052 (Port Of Defect DCSG00150459)
-Segmentation with controller show summary command when controller is in unsupported state.(DCSG00215109 (Port Of Defect DCSG00215118))
-StorCLI show autoconfig does not display all properties it can set.(DCSG00071834 (Port Of Defect DCSG00080859))
-Storcli returns wrong Operating system in Windows..(DCSG00037088 (Port Of Defect DCSG00037336))
-No description for "set autoconfig=R0 immediate" command..(DCSG00129610 (Port Of Defect DCSG00129762))
-Displaying connected portnumber as per API supportMoreThan16Phys.(DCSG00104331 (Port Of Defect DCSG00108740))
-Compare Factory command execution fails in storclif.(DCSG00074182 (Port Of Defect DCSG00074207))

EnhancementRequests:
-HPE : Windows and Linux StorCLI signing.(DCSG00053511)
-Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG..(DCSG00105430)
-API change to support ISE completion status.(DCSG00065881)
-MR API: Change event class for SPDM events.(DCSG00134416)
-API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI.(DCSG00222915)
-Perccli: Need a mechanism to get supported device protocols for each controller form factor.(DCSG00117742)
-support for sanitize command.(DCSG00108999)
-Shenandoah: Support for the New Energy Pack states.(DCSG00043240)
-Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713)
-Remove Help Text for lanespeed commands.(DCSG00099939)
-Shenandoah: Change the CLI installation Directory name from Megaraid to hpe.(DCSG00053988)
-Porting storcli source from V8 Clearcase to CC9 GCP database.(DCSG00013486)
-Creating VD with 0 MB or GB should not be allowed to succeed --ve case boundary value scenario.(DCSG00048859)
-MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534)
-DCSG00129388
-Support to display drive connector name information for SAS3.5 IT Controllers.(DCSG00120994)
-Add segment area into pci information of Megaraid controller in storcli.(DCSG00032694)
-Populate secureboot properties "KeyUpdatePending" and "Remaining Secure Boot Key slots" in StorCLI.(DCSG00101684)
-Remove (hide) PCIe Link form in HII and from CLI for Perc11.(DCSG00077856)
-Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066)
-Signing Linux executables via GPG method in HSM.(DCSG00077215)
-Shenandoah: Creating VD with 0 MB or GB should not be allowed to succeed - Part 2.(DCSG00053587)
-Shenandoah: SSD Wear Gauage.(DCSG00046064)
-MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355)
-Add /px linkspeed back to help text.(DCSG00126913)
-HSW Applications to not send close DCMD as the first command to perform Firmware update.(DCSG00055146)
-Update/remove Snapdump save count field in show snapdump command based on FW support.(DCSG00038800)
-Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780)
-API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058)
-Add new security events.(DCSG00167313)
-Request for DPMstat support in MegaRAID SAS 3.5 controllers in storcli.(DCSG00032273)
-MR API: update field in event structure..(DCSG00093331)
-Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286)
-SMART Polling Improvement- API Changes.(DCSG00214352)
-References to MR_ENCL_LIST and MR_ENCL_LIST_EXT should be based on the support bit.(DCSG00037323)
-Shenandoah: Type 2 Back plane Support for StorCLI.(DCSG00054795)
-StorCLI: Implementing span depth logic and pd per array count for RAID 10.(DCSG00049781)
-Updating BST scripts to support auto BST through VBAS in clear case version 9.(DCSG00050763)
-FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event.(DCSG00086780)
-Revert the CLI Help Text for backwards compatibility to include Dimmer Switch 3.(DCSG00068659)
-Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10.(DCSG00073393)
-New MFI Stat for the updated recon behavior.(DCSG00229416)
-Shenandoah: Remove Span setting for RAID 1 & 10.(DCSG00043198)
-Restore Factory Default doesn't prompt user to reboot the system after being performed.(DCSG00122000)
-MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security.(DCSG00106380)
-Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847)
-Phase 14 : StorCLI should provide power cycle message post erase all command is executed.(DCSG00039542)
-Enhancement of Enclosure MultiPath algorithm in storcli.(DCSG00075191 (Port Of EnhancementRequest DCSG00079538))
-Support to generate storcli static library.(DCSG00075265 (Port Of EnhancementRequest DCSG00075687)
-Updating toolchain for VMware7.0 GA.(DCSG00134764 (Port Of EnhancementRequest DCSG00136269))



007.1212.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------  
MR 7.12

Defects:
StorCLI should refer to MR_PD_INFO.properties.ISECapable to display "Cryptographic Erase Capable" field - Revert of SCG(DCSG00014660)
Making the Predictivefaliure  check OEM specific in controller health algorithm(DCSG00014971)
HBA345_Dev_UT: Enclosure position value in perccli is same for both front and rear BP's(DCSG00033180
Cisco - CSCVr89052 - PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup(DCSG00050891)
StorCLI Point release RO DCSG00079546 - Windows binaries are missing from the RO(DCSG00081022)
 StorCLI 7.10 point release  - /cx erase help not listing all supported commands(DCSG00081294)
StorCLI 7.10 point release - Update license files to RO DCSG00079546(DCSG00081298)
Removal of unsupported phy commands on IT3 controller(DCSG00025416)
Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(DCSG00015875)
MR_6.14_Huawei: OnDemand Snapdump in Windows gives failure message "RTTdump Feature not supported"(DCSG00020717)
help is not proper for show events and set copyback commands(DCSG00005503)
MR 7.12: Storcli: Instance Validation Failed for "/call show all" and controller-detailed-properties-schema(DCSG00006331)
MR 7.12: Storcli: Instance Validation Failed for "/call/pall show all" and controller-phyerrorcounters-schema(DCSG00006853)
Orion PA9 : Convention comes in same line while performing help for /c0/e0/s0 download.(DCSG00008084)
MR_7.12_Storcli: Xenserver8: "Core dumped" while executing "/call/eall show all" and "/call/eall/sall show all"(DCSG00009400)
Aero DBU PA7 : Init is in progress error message is thrown by Storcli for start migrate command when VD erase is in pro(DCSG00012344)
Orion PA9 : Storcli version mismatch as compared in storcli -v and storcli properties(DCSG00014485)
Orion PA9 : Storcli crashes while performing storcli /c0 show(DCSG00014486)
Storcli show all cmd displaying "AVAGO" in scheduled tasks info(DCSG00014580)
Aero DBU PA7 : Storcli displays multiple error messages when user enters incorrect device ID during migrate operation.(DCSG00014644)
Fixing Coverity defects - resource leaks and null referencing(DCSG00015721)
Correcting the detailed help syntax(DCSG00016268)
MR7.12 StorCLI: Ouptput message Description wrong for StorCLI VD policy change from WT -WB(DCSG00016372)
StorCLI:  Fixing coverity defects and adding debug statement(DCSG00019683)
perccli windows binary property page has storcli references(DCSG00019800)
Aero DBU Alpha : Storcli displays incorrect error message for "add vd each r0" command when SED drive is connected in t(DCSG00019816)
Application Exit code is always success for UEFI StorCLI(DCSG00020670)
MR 7.12 LSA "instant secure erase" is not found in storcli as cli use secureerase(DCSG00022096)
Help content for Drive Init is not showing it as Clear operation(DCSG00022893)
MR7.12_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(DCSG00022942)
MR 7.12: Storcli: Instance Validation Failed for "/call start Diag Duration=40" and controller-diag-schema(DCSG00023543)
MR 7.12: Storcli: Instance Validation Failed for "/call show linkconfig " and controller-linkconfig-schema(DCSG00023545)
Aero Alpha : Storcli throw Segmentation Fault in Driver load error handing path -(DCSG00024554)
MR 7.12_Storcli: On ARM server the latest storcli Vendor,Licenses,URL and distribution shows as "AVAGO Technologies"(DCSG00025885)
Aero DBU Alpha - Scheduling is displayed as Schedulling under "/cx set pr ? " command description(DCSG00027203)
Add warning/recommendation messages for changing lane speeds(DCSG00027869)
Orion MR : Description for storcli output is not proper after collecting the snapdump with id=all(DCSG00031711)
Aero Alpha: Storcli stops functioning during run of attached script(DCSG00034379)
Storcli returns wrong Operating system in Windows.(DCSG00037088)
MR 7.12_Storcli: The latest storcli vmware build reference URL shows "http://www.lsi.com"(DCSG00039104)
MR 7.12_Storcli: The latest storcli vmware build 007.1209.0000.0000 shows older package version(DCSG00039112)
PERC 11:EKMS:PKG 2973: EKMS Boot Agent Status is not updating properly.(DCSG00049004)
PH13 StorCLI PA - Update help section about 'nolog' option(DCSG00002975)
PH13 PA - StorCLI - Incorrect message for /call/pall show all command(DCSG00003003)
StorCLI_7.12_Ph13:Phyreset Fails on IT controllers(DCSG00005488)
PH13 PA - StorCLI - NVMe drive linkspeed not seen with /cx/pall show(DCSG00009522)
With IT controller for set or reset with invalid phy is not showing error(DCSG00010226)
Aero_storecli:Using latest storecli Firmware product id parameter value fail to display.(DCSG00011446)
MR_7.12: Storcli: Segmentation Fault for "storcli64 page"(DCSG00012563)
Storcli ph13: Fixing array size for function DEBUG_LOG(DCSG00014665)
Aero Orion IT:- Mismatched phy info listed for 440-16e/440-16i(DCSG00023320)
Enclosure position value in storcli is same for both front and rear BP's(DCSG00031302)
Misleading error message when create unmap VD with storcli64.exe /c0 add vd each r0 unmap using unmap and non-unmap PDs(SCGCQ02059720)
StorCLI: Debug prints enabled in latest Phase 12 PA storCLI.efi image(SCGCQ02097317)
Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101372)
MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json(SCGCQ02112192)
DBU Aero PA4 : Cosmetic error is seen in command description for Show SSDThermalPollInterval ?(SCGCQ02124673)
Aero A0 PA4: "Storcli /c# set jbod=on" shows success but does nothing(SCGCQ02117219)
Aero (DBU PA4):Storcli: Junk character in PD start locate command description.(SCGCQ02125654)
Phyreset Fails on IT controllers and update help(SCGCQ02169242)
Drive mode-e fw download with activatenow is not working(SCGCQ02142068)
MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02150924)
MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02165933)
Phase 12 - Oct Huawei DET - "./storcli64 /c0/pall show" Command Fails With "Null pointer exception"(SCGCQ02175414)
Phase 16 (IR) - Oct Huawei DET - Unsupported Drive State is Displayed for "./storcli /c0 show" Command(SCGCQ02170389)
MR 7.11 - Oct Huawei DET - Nomenclature Issue for "rbld=Rebuild" In Storcli Show Help Menu for SAS3516(SCGCQ02170197)
Usage of 64 bit address instead of 32bit address while sending commands to FW in uEFI driver less environment(SCGCQ02174934)
MR_7.10_Storcli: Storcli displays incorrect error message for unmap VD creation with regular HDD drives.(SCGCQ02019751)
PH12 PA - StorCLI crashes when call/pall show executed with SAS3 & Ventura boards(SCGCQ02103217)
PH12 PA - StorCLI - Debug StorCLI binary is placed in both places of EFI dir RO SCGCQ02085693(SCGCQ02091140)
PH12 PA - Update readme file in VMwareOP64 folder in accordance with PR SCGCQ01923533(SCGCQ02108550)
MR 7.11: Storcli.efi: In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02115036)
Aero (DBU PA4):Storcli:  VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508)
Aero DBU PA4 : storclif /cx show configautobalance  ? help output shows the name as "show NCQ"(SCGCQ02124632)
Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02136333)
Aero (DBU PA5):Storcli: Storcli: "/c0 set patrolread ?" lists detailed help and snapdump rttdump is mentioned as optional.(SCGCQ02140873)
MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02150921)
Aero (DBU PA5):Storcli: Force is not mentioned as key word in "/cx/vx del" error message.(SCGCQ02142017)
MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(SCGCQ02165944)
Aero (DBU PA5):Storcli: "Ctrl" legend not mentioned.(SCGCQ02146822)
MR7.11_Storcli: storcli set securitykey detailed help does not show description for all the options(SCGCQ02096732)
MR7.11_Storcli: storcli show output shows UBUnsp as UBad Unsupported where as UGUnsp just Unsupported(SCGCQ02096722)
Aero IT - PA3 - StorCLI crashes for 'storcli J command(SCGCQ02117749)
Lenovo Orion IT:- Command to flash UEFI on Aero/sea HBA from storcli/scrutiny fails(SCGCQ02137751)
Flashing of Completeflash fails on Sea IT controller(SCGCQ02139780)
StorCLI: Fixing coverity defects(SCGCQ02123769)
MR 7.11: Storcli: Instance Validation Failed for /call/show_smartpollinterval.json and controller-smartpollinterval-schema.js(SCGCQ02135516)
DBU PA5 Aero : Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02132024)
Aero (DBU PA5):Storcli: No "Rbld" legend during rebuild.M(SCGCQ02146819)
complete Lane WWID is not displayed(SCGCQ02145716)
Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176681)
Adding missing syntax for the command deviceorderbyfirmware(SCGCQ02121705)
MR 7.11: Storcli: Instance Validation Failed for "/call/vall show unmap" and vd-unmap-schema.json.(SCGCQ02113316)
Aero (DBU PA5):Storcli: "completeflash" is listed in Windows help file.(SCGCQ02141931)
Aero (DBU PA5):Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02140878)
Force option is needed only for Parallel Drive microcode update, but it allows to take for normal also(SCGCQ02177086)
StorCLI Copyright Notice Needs to be updated(SCGCQ02174040)
Wrong error message when create unmap VD with unmap disable on controller(SCGCQ02064118)
Aero DBU PA4 : storclif /cx delete colinfo  ? shows syntax error(SCGCQ02124492)
MR 7.11: Storcli: Instance Validation Failed for "/call show" and controller-properties-schema.json.(SCGCQ02108770)
PH12 PA - StorCLI version not getting printed for show file command(SCGCQ02105185)
Aero DBU PA4 : Command name shown in help output differs for storclif.efi /cx show limitmaxrateSATA ?(SCGCQ02124667)
Aero DBU PA4 : Redundant information is displayed for set driveactivityled command in storclif.(SCGCQ02124675)
Aero (DBU PA4):Storcli: Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252)
Aero DBU PA4 : storclif.efi /cx show deviceorderbyfirmware ? throws syntax error.(SCGCQ02124528)
MR 7.11: Storcli: Instance Validation Failed for /call/show_consistencycheck.json and controller-cc-schema.json(SCGCQ02135510)
Phase12-Storcli- In Windows storcli64.exe /c0 show htbparams is showing random values for SAS3 controller(SCGCQ02125598)
Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02140859)
PH12 BETA - /cx erase help not listing all commands(SCGCQ02146466)
Aero (DBU PA5):Storcli: No consistency in the usage of "|" in the command such as "on|off".(SCGCQ02142022)
Phase 12 - Oct Huawei DET - Delay Option In PD Download Operation is Not Honored(SCGCQ02176690)
With IT controller for set or reset with invalid phy is not showing error(SCGCQ02181823)
Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02184862)
Drives connected to active backplanes not showing the phy info in connector name(SCGCQ02112424)
PH12 PA - StorCLI - 9310-8i IR FW download fails(SCGCQ02121783)
MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02114898)
Aero PA6 - storcli snapdump id=x errors without optional file parameter(SCGCQ02161748)
PH11 - StorCLI - Incorrect message for /call/pall show all command(SCGCQ02169536)
cli does not allow  to do crypto erase on SATA SSD.(SCGCQ02147075)
MR7.11_Storcli: Storcli stop erase needs an help file update(SCGCQ02168895)
Phase 12 - Oct Huawei DET - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180495)
Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(SCGCQ02191421)
Aero PA4 DBU : Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02123789)
Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091)
Aero (DBU PA4):Storcli: /c0 compare lists /c0/px compare command.(SCGCQ02124246)
StorCLI: Fixing coverity issue in libmod(SCGCQ02123790)
SWR:Storcli: "Show" and "show all" output Description is shown as "No Enclosures found"(SCGCQ02146814)
MR 7.11 storcli -help missing the verbose option(SCGCQ02158600)
Phase 12 - Oct Huawei DET - PD FW Download is failing for Mode f(SCGCQ02168197)
PH12 PA - StorCLI - Incorrect string displayed with show command in FreeBSD 11.2(SCGCQ02094529)
PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02119004)
MR 7.11: Storcli: Instance Validation Failed for "/call/v5 set bootdrive=off" andcontroller-bootdrive-schema.json.(SCGCQ02115786)
StorCLI: Fixing coverity defects for second run(SCGCQ02125523)
MR 7.11: Storcli: Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02135526)
Aero (DBU PA5):Storcli: /c0 set ? lists bbu,mx,px and lnx commands.(SCGCQ02136689)
Aero DBU PA4 : Storclif should not display vendor name in storclif.efi  /cx/ex download help command(SCGCQ02123765)
Aero (DBU PA5):Storcli: Improper spacing for the linkspeed description and "YY" parameter leads to confusion.(SCGCQ02139910)
MR 7.11: Storcli: Instance Validation Failed for /call/show.json and controller-properties-schema.json(SCGCQ02135420)
MR 6.14 - Oct Huawei DET - "Rbld=Rebuild" is Not Available In Storcli Show Help Menu for SAS3108(SCGCQ02170181)
MR 7.11: Storcli: Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02150651)
Aero (DBU PA5):Storcli: Help notes needs an update.(SCGCQ02146823)
Phase 12 - Oct Huawei DET - Incorrect Status for PD FW Download (Ventura IT)(SCGCQ02173203)
Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02174296)
	
Enchancement:
To bring MR 7.10 storcli change to CC9 GCP database(DCSG00013486)
Support to generate storcli static library(DCSG00075265)
Bring MR 7.11 storcli change to CC9 GCP database(DCSG00014492)
Updating the Makefile and projects as per new CC/CQ changes(DCSG00003002)
Updating the Json Schema files with respect to the latest code(DCSG00007394)
Controller commands Json Schema files update as per the latest code(DCSG00007435)
Schema validation : Schema update for VD/DG/Foreign related commands(DCSG00007453)
Add UEFI Shell StorCLI support for 64-bit Ventura Gen MR Legacy Boot solutions (solutions without UEFI driver)(DCSG00008200)
Changing the CBB download image type as per new MR API(DCSG00010253)
Migrating StorCLI's 64 bit VMware toolchain to 6.8.7-13394445(DCSG00014503)
PERC 11: Provide ability to expose SEP to host and disable PERC SES management in PercCLI / HII(DCSG00015020)
Supporting build and BST process through VBAS in Clear Case version 9(DCSG00024818)
Windows and Linux StorCLI HSM based signing support(DCSG00031618)
StorCLI PH13: Adding interface for lane display and configuration command for IT controllers.(DCSG00007909)
Atlas Support on Aero-IT(DCSG00008038)
Concern for security key passed in from storcli to be read in process data(SCGCQ02066380)
Support FMP Images in UEFI Version of PERCCli(SCGCQ02078649)
Add segment area into pci information of Megaraid controller in Storlib and storcli(SCGCQ02201178)
Create DVT / PVT PnP IDs for Cisco Pismo Beach card(SCGCQ02108965)
Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066395)
Enable SnapDump for iMR(SCGCQ02208421)
HDET: Support in storCLI support PD firmware download for 3008IR/3008IT controllers(SCGCQ02160016)
multi VSES implementation(SCGCQ02066438)
Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066399)
Add displaying list of enclosures in controller show and show all command(SCGCQ02124566)
LibMod changes : MR: 64 Bit  Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02085102)
SAS 3_5 Ventura family UEFI NVMe drive serial number issue(SCGCQ02074657)
Unmap error message changes as per new description in MR API(SCGCQ02115017)
MR: 64 Bit  Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02066386)
Lenovo Whitley/Orion - Addendum 7 - Lenovo request to support StorCLI & LSA for Valvano 28i (MR+Cub) and Custom Form Factor(SCGCQ02082612)


007.1022.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects :
 - PERCcli Help text is missing description for "Lane Information"(SCGCQ02150899) 
 - Add NVMe width comments to mr.h(SCGCQ02146846) 
 - Fix API changes done for NVMe readiness(SCGCQ02142981) 
 - CLI returns "success" when attempting to set DS3 or DS4 to enabled(SCGCQ02116380) 
 - CLI returns "success" when attempting to change the H840 controler to eHBA personality.(SCGCQ02114332) 
 - CLI returns wrong error code upon failure(SCGCQ02084966) 
 - HPE shenandoah: storcli crashes during show command when DGs present(SCGCQ02065695) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02045324) 
 - ROP version not displayed with latest ROP version SCGCQ02035462(SCGCQ02041094) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option(SCGCQ02035152) 
 - retentiontest command is successfully triggering BBU test on Shenandoah controller(SCGCQ02021398) 
 - Storclio (007.0911.0000.0000) detailed help file doesn't have " locale " option for flashing FW in Dual/Active & Backup mode.(SCGCQ02012025) 
 - hot spare reference in Add Spare command output(SCGCQ01897463) 
 - Shenandoah:Strocli show all output return failure but generates output(SCGCQ01929191) 
 - Junk message "STR_JBOD_OBJ" is displayed in the output of storcli /c0 show JBOD command.(SCGCQ01932770) 
 - Shenandoah_StorCLI: No legend presend for VD Delete Failure(SCGCQ01936811) 
 - Shenandoah_StorCLI:Setting Unmap=OFF gives success for a LD when unmap is not supported and not enabled on that LD(SCGCQ01940291) 
 - Set WrCache= WB ,says success even though VD is in WT.Proper warning message should be given to the user(SCGCQ01940296) 
 - Legend missing for LD BGI resume/pause commands(SCGCQ01940347) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945551) 
 - Shenandoah_StorCLI: Storcli crashes on checking LD preserved cache info(SCGCQ01955069) 
 - CLI is showing the incorrect OS version(SCGCQ01956276) 
 - Unified StorCLI : Add extra space to CBB header(SCGCQ01956678) 
 - PH10 Alpha - StorCLI throws "0 Failed 32782 Failed to get PD Info" when /c0 show executed in EFI(SCGCQ01960322) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01961527) 
 - supported personalities has blank value(SCGCQ01965370) 
 - storcli faults for enclosure show command(SCGCQ01985815) 
 - MR7.10_PA1: Storcli binaries for RHEL/SLES OS is not present for ARM(SCGCQ02006374) 
 - NVMe drive displays incorrect information with IT card(SCGCQ02009852) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02016762) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for snapdump commands.(SCGCQ02018073) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02018134) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02018135) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02018140) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02018333) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02019740) 
 - Instance Validation Failed between " controller-lane-show-schema.json" and "/call/lnall show"(SCGCQ02019746) 
 - Pending Image details are not populated after FW upgrade and downgrade.(SCGCQ02024065) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all "(SCGCQ02032911) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02034493) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02035370) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure(SCGCQ02053910) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02061340) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show_all"(SCGCQ02062957) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02064836) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02064839) 
 - PH11 Alpha - StorCLI 'show file' command throws segmentation fault for complete flash image in FreeBSD(SCGCQ02065691) 
 - Storcli: No schema files for htbparams commands.(SCGCQ02065698) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02065734) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02067575) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02069817) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02070951) 
 - Aero (DBU PA2): Storcli: No syntax error displayed for "storcli mronly" command.(SCGCQ02072746) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02076923) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02076931) 
 - htbparams help output needs update.(SCGCQ02077156) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02078437) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02078513) 
 - Recon command (./storcli /cx set recon) is throwing syntax error.(SCGCQ02081415) 
 - storcli /c0/ex/s23,24 show patrol read doesnt not show error for slot 24 (Invalid Slot)(SCGCQ02082142) 
 - Aero (DBU PA2): Storcli show detailed help does not list "show all " command.(SCGCQ02082303) 
 - Aero (DBU PA2): Storcli: Get rttdump detailed help shows syntax error.(SCGCQ02082460) 
 - Storcli: Incorrect message while executing "storcli64.exe /c0/v0 del discardcache"(SCGCQ02083828) 
 - Failure status for /call/sall and /call/eall/sall command.(SCGCQ02084549) 
 - Storcli: Error in /c0/f0 command output.(SCGCQ02089892) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02090770) 
 - Storcli doesn't exit with controller status message after doing OFU.(SCGCQ02091548) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02096774) 
 - Aero (DBU PA3): Storcli: FW hits Megamon while executing storcli in EFI shell when EFI Driver is unloaded.(SCGCQ02097647) 
 - StorCLI crashes for 'storcli J command(SCGCQ02117749) 
 - Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) 
 - Controller Health Status not consisten across applications(SCGCQ02182243) 
 - Perccli does not enable Power Save mode for UG & HS type 1 & type 2.	(SCGCQ02125408) 
 - StorCLI: Delete config failure message need correction(SCGCQ02086726) 
 - StorCLI:VD reference in Delete preserved cahce command output -Branding(SCGCQ02083992) 
 - VD reference in set JBOD command output message(SCGCQ02078507) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02075242) 
 - STORCLI: Show command output having wrong legend for Slt for oem Hercules(SCGCQ02067616) 
 - Grammatical error in Perccli message(SCGCQ02065513) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02045967) 
 - VD legend missing in the legend for Foreign config show all output(SCGCQ02016798) 
 - Hercules:Shenandoah:Transformation is coming as Reconstruction , while migrating the Raid 1 to Raid 5 .(SCGCQ01897468) 
 - Mis-spelled words in StorCli's Help(SCGCQ01898853) 
 - Hot spare reference in storcli.exe /cx/ex/sx show all command output(SCGCQ01905019) 
 - Reference to VD in storcli.exe /c1/jbodall delete command output(SCGCQ01905077) 
 - Fixing coverity issues Removing dead code and Out of bound access(SCGCQ01924504) 
 - Shenandoah_StorCLI: HotSpare reference in Add VD Command output(SCGCQ01936887) 
 - storcli /c0 show events output not listing the Event ID's(SCGCQ01940290) 
 - Shenandoah_StorCLI:Hot spare reference in storcli64 /cx show/set restorehotspare command outputs(SCGCQ01940437) 
 - Shenandoah_StorcLI:Drive Group reference in Add dedicated spared drive command in CLI(SCGCQ01955167) 
 - Intel NVMe drive "Model Number" displayed incorrect under Device Attributes(SCGCQ01957949) 
 - Aero: Segmentation Fault in storcli /c0 show all(SCGCQ01996444) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02006450) 
 - storcli gives error when the lane configuration is set as X8	(SCGCQ02007152) 
 - MR_7.10_Storcli: No schema file for controller unmap commands(SCGCQ02016749) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-restorehotspareoninsertion-schema" and "set restorehotspare"(SCGCQ02016765) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-properties-schema" and "/c0 show"(SCGCQ02016768) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02016771) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-autoconfig-schema.json" and "show autoconfig" JSON output.(SCGCQ02018227) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02018277) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02018305) 
 - MR_7.10_Storcli: Instance Validation Failed between "system-schema.json" and "./storcli show" and "show all" JSON output.(SCGCQ02018313) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02018327) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02019729) 
 - Storcli displays drive state as UBad instead of UBad (unsupported)(SCGCQ02031615) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02040779) 
 - Fixing coverity issues Fixing resource leaks(SCGCQ02043601) 
 - Storcli help file should show the expand size format.(SCGCQ02047109) 
 - Updating the storcli schema mapping document	(SCGCQ02050586) 
 - PH11 Alpha - StorCLI - Parse error observed for command 'StorCLI J' while validating Jason(SCGCQ02053030) 
 - JSON-SCHEMA : IT-Controller Json-schema validation erros in MR_SAS_Unified_StorCLI_7.10(SCGCQ02053914) 
 - Aero: Storcli : Storcli crashed when Firmware upgrade tried on Sea controller(SCGCQ02060276) 
 - Aero (DBU PA2): Storcli: JSON readme file does not have complete VD and PD support list.(SCGCQ02061328) 
 - Instance Validation Failed bw "enclosure-drive-detailed-schema.json" & "/call/eall/sall show all"(SCGCQ02062958) 
 - PH11 Alpha - StorCLI - Compare linkspeed command failed for 6Gbps link(SCGCQ02063932) 
 - Invalid aero controllers are not displayed with apt message in driver less mode(SCGCQ02065581) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02072448) 
 - Aero (DBU PA2): Storcli: /cx/mx command does not mention about "Auto" settings.(SCGCQ02082208) 
 - Storcli: Force is mentioned as optional in snapdump delete command.	(SCGCQ02083822) 
 - Help of /cx/px compare command needs update and /cx/px reset ? shows syntax error.(SCGCQ02084752) 
 - No proper legends in /fall output.(SCGCQ02100491) 
 - Aero (DBU PA3): Storcli: Incorrect schema mapping for "/cx set autoconfig " command.(SCGCQ02101558) 
 - Storcli: OCR helps needs update.(SCGCQ02113241) 
 - Storcli: No proper description of set and show sesmultipathcfg.(SCGCQ02113358) 
 - StorCLI: File sync issue with rel and dev stream for MR 7.10	(SCGCQ02116806) 
 - Storcli script stops with error "can't fork: Cannot allocate memory"	(SCGCQ02184427) 
 - IT- CLI treats EID and Partner Device ID as two different enclosure during pd info command and fails.(SCGCQ02185442) 
 - "/eall show" will not show enclosure details if it is in multitpath & no drives connected.(SCGCQ02186022) 
 - Legacy messages present with create and rekey of securitykey on controller(SCGCQ01581843) 
 - Shenandoah_StorCLI:VD reference in CLI outout for Firmware update command failure case(SCGCQ02083991) 
 - StorCLI: VD listing for c0 show and vall show is toggled	(SCGCQ02078936) 
 - output information for link configuration is displayed incorrectly(SCGCQ02073046) 
 - Drive Groups is shown instead of arrays in show all command(SCGCQ02048660) 
 - Help is not updated for get snapdump without ID option.(SCGCQ02046991) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02040783) 
 - Adding debug logs to Mfi files(SCGCQ01891583) 
 - MR7.8_Storcli: Storcli fails to install on ARM server with Missing Maintainer message(SCGCQ01919830) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01921258) 
 - Unified StorCLI 7.9 : Fixing coverity issues - Dead code,resource leaks,and memory corruption - Part 1(SCGCQ01925503) 
 - Incorrect help option for set autoconfig in StorCli's Help(SCGCQ01932035) 
 - Unmap enabled property is shown in VD detailed properties when controller does not support unmap	(SCGCQ01932177) 
 - Unified StorCLI - Aero : "FullFlashImage" environmental variable component stamp change(SCGCQ01963738) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON output.(SCGCQ02018322) 
 - MR_7.10_Storcli: Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show"(SCGCQ02024327) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034064) 
 - Aero IT - PA1 - StorCLI - BIOS verion not displayed with flash file using 'show file' command(SCGCQ02034490) 
 - failure in StorCLI enclosure show status	(SCGCQ02040640) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02042106) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02043610) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044777) 
 - Port information is not displayed for Vses Backplane(SCGCQ02053070) 
 - "c0 delete ?" does not list snapdump command.(SCGCQ02053639) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02062834) 
 - Aero (DBU PA2): Storcli: Instance Validation Failed bw "vd-operations-migrate-schema.json" & "start_migrate"(SCGCQ02062960) 
 - Aero (DBU PA2): Storcli: Result shows blank for "resume patrolread" failure case.(SCGCQ02064795) 
 - Fail to set the linkconfig .	(SCGCQ02070797) 
 - Storcli /c2 set linkconfig conname=c0,c1 configid=14 returns invalid syntax error(SCGCQ02070953) 
 - Aero DBU PA2 : Syntax error is seen in storcli /cx(x|all	(SCGCQ02077085) 
 - Aero (DBU PA2): Storcli: Syntax error for "/c0 download psoc/efibios/cpld/fcode ?" download commands.(SCGCQ02077175) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02078409) 
 - Incorrect string displayed in show command in FreeBSD OS(SCGCQ02082949) 
 - MR_7.10_Storcli: "storcli show file=filepath" command shows failure status.(SCGCQ02085630) 
 - PCI Linkconfig configid status is failure, even though it was set(SCGCQ02086669) 
 - Storecli_Aero: Using latest storecli show file command "Aero-DVT -HBA 9500-16e" board output version number shows wrong.(SCGCQ02089427) 
 - Libmods changes for defect SCGCQ02062957(SCGCQ02089862) 
 - Help update for "add vd cachevd" command as Normal VD is created with failure status.(SCGCQ02091155) 
 - Preserved cache help file shows a mismatch in command and the convention.(SCGCQ02106218) 
 - Aero DBU PA4 : Storcli doesn't show the convention details properly for storclio /cx/px show command(SCGCQ02113377) 
 - Aero (DBU PA4):Storcli: Syntax error for /c0 show AliLog ?(SCGCQ02113506) 
 - Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) 
 - Misleading error msg "157 Failed Cannot mix unmap and non-unmap physical drives in same array"(SCGCQ02151484) 
 - Cryptographic erase field is shown "yes" but crypto erase fails.(SCGCQ02175346) 
 - Device Type for non-UBM backplanes are being shown as Enclosure instead of Backplane(SCGCQ02101095) 
 - Multiple status messages are displayed in the output	(SCGCQ02073042) 
 - Controller health status is shown as optimal when megacell cable is disconnected.(SCGCQ02021393) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"(SCGCQ01889700) 
 - Shenandoah_StorCLI:32 Binary crashes on giving invalid input to the command storcli.exe /c0/jbod0 show(SCGCQ01905831) 
 - For NVMe drive use the term NVMe instead of PCIe(SCGCQ01923119) 
 - PD show all command displays SSD weargauge details , which is not required.(SCGCQ01927864) 
 - MR_7.10_Storcli: Junk character in error message while creating SED vd with regular HDD drives.(SCGCQ02016701) 
 - MR_7.10_Storcli: Incorrect command syntax mentioned in Schema_mapping_list.xlsx file for "/cx set autoconfig" command.(SCGCQ02018097) 
 - Instance Validation Failed between "vd-operations-bgi-schema.json" and "/call/v1 show bgi " and "show init".(SCGCQ02035551) 
 - Storcli shows incorrect output for delete events command(SCGCQ02045816) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02048150) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053923) 
 - StorCLI displays expansion as successful even when there is no free space to expand(SCGCQ02057361) 
 - Instance Validation Failed between "controller-patrolread-schema.json" and "/call resume patrolread"(SCGCQ02062942) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02063689) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02064120) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02064828) 
 - Aero (DBU PA2): Storcli: Inconsistency in "add vd" command syntax.(SCGCQ02082196) 
 - Details are displayed twice in "/cx/bbu start ? "(SCGCQ02100905) 
 - Storcli: set termlog shows [=on|off] mentioned as optional.(SCGCQ02113353) 
 - CLI is missing the JBOD PD size for SysPDs when using the "show jbod" command(SCGCQ02132277) 
 - Percli returns “invalid arguments" when trying to create a VD using some PDs already configured in a VD and some U(SCGCQ02122169) 
 - Topology information missing from Storcli output(SCGCQ02048612) 
 -	(SCGCQ02040597) 
 - Unified StorCLI: StorCLI does not return the return code from SLIT/SLIR3 to explorer/command processors(SCGCQ01925156) 
 - Virtual drive reference in Delete Preserved cache command output(SCGCQ01940333) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940805) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01948579) 
 - Shenandoah : Firmware receives incorrect erase type for sanitize crypto erase option(SCGCQ01958564) 
 - Storcli shows BBU present instead of EnergyPAck in HWcfg for StorCLI /cx show all output.(SCGCQ01985592) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Sea (3816_Eval) IT Controller(SCGCQ02008219) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for errorcounters commands.(SCGCQ02018078) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02030652) 
 - There is no error message for smart drive failure command.(SCGCQ02040645) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02046036) 
 - JSON Schema : Updating the schema list with Virtual drive command set(SCGCQ02057360) 
 - storecli_Aero:In linux error message observed in the show output.(SCGCQ02057699) 
 - Checking in JSON schemas(SCGCQ02061305) 
 - Junck character displayed in Virtual SES phy id, when we query phyerror counter for enclosure.(SCGCQ02094970) 
 - Aero (DBU PA3):Storcli: Help of /cx/px reset does not mention about option hard reset.(SCGCQ02100896) 
 - BBU show detailed help does not list "show learn " command.(SCGCQ02100915) 
 - Storcli: Instance Validation Fails for all /call/e65/sall commands where "e65 is not found".(SCGCQ02101564) 
 - Storcli: Remove Nytro supported options in "/cx [start] flush|flushcache [cachecade | ALL]" help.(SCGCQ02113484) 
 - MR7.10 cli return mesg. typo after ctrl restart then immediately running storcli64 /c0 show.(SCGCQ02113833) 
 - Storcli: /c0 compare help lists /c0/px compare command.(SCGCQ02124246) 
 - Serial number not displayed fully in 7.10 StorCLI 007.1017.0000.0000 for IT Controller(SCGCQ02173789) 
 - Hide BBU details from the command "storcli /c0 show alilog" for HPE(SCGCQ01937259) 
 - Disk group is displayed instead of array on HPE platforms(SCGCQ01965366) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02016758) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02024740) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02034471) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02035437) 
 - Instance Validation Failed for "/call show and /call show all".(SCGCQ02101432) 
 - Instance Validation Failed bw "drive-group-detailed-schema.json" and "/call/dall show all".(SCGCQ02101513) 
 - Autoconfig options are allowed to set with latest storcli(SCGCQ02053643) 
 - Unified StorCLI Phase 10 : Image checksum should not be performed for aero images(SCGCQ01942200) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02035439) 
 - Fixing coverity issues Fixing resource leaks and explicit NULL dereferencings(SCGCQ02042242) 
 - Unified StorCLI : Fixing resource leaks - Part 1(SCGCQ02042513) 
 - Updating Schema mapping doc and fixing validation errors	(SCGCQ02057434) 
 - Storcli: Instance Validation Fails for vd-bootdrive-schema.json and vd-unmap-schema.json.(SCGCQ02101568) 
 - Aero_storecli:Using latest storecli firmware download fail with noreset option.(SCGCQ02101570) 
 - Aero DBU PA4 : Syntax error is seen for the command - storclio.efi /cx/px set state ?(SCGCQ02113123) 
 - PD info incorrectly shows Number of Blocks for >TB drives(>3TB in my case(SCGCQ02183653) 
 - CLI is returning "success" when attempting to set bios mode to Ignore Errors.(SCGCQ02121017) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02084833) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01892288) 
 - Initialize the MFG structure(SCGCQ01901166) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Aero (3916_Eval) IT Controller(SCGCQ02021194) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02040756) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02042296) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047100) 
 - Updating storcli-cmd-list.xlsx for Drives(SCGCQ02056199) 
 - Message with Incorrect controller object is displayed while setting SSD Caching on VD(SCGCQ02057085) 
 - Storcli displays grammatically incorrect message in detailed help file.(SCGCQ02097641) 
 - MR_7.10: Storcli: Property is shown as SCSI Umap instead of SCSI Unmap.(SCGCQ02101572) 
 - Storcli: /c0 show detailed command does not list /cx/px show phyerrorcounters and /cx show vpd.(SCGCQ02113262) 
 - Aero (DBU PA4):Storcli: Incorrect description of "/c0/v0 show migrate" command.(SCGCQ02113511) 
 - Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) 
 - Storcli: Junk character in PD start locate command description.(SCGCQ02125654)
 - Storcli doesn't exit with controller status message after doing OFU.	(SCGCQ02101069 port of SCGCQ02091548) 
 - perccli /c0 show all lists topology without any DG's present	(SCGCQ02085925 port of SCGCQ01998332) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - Libmods: HPE serial number display(SCGCQ02062634 port of SCGCQ01885657) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979616 port of SCGCQ01979599) 
 - Hide "set pdfaileventoptions" command from CLI Help(SCGCQ01892551 port of SCGCQ01880722) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01911777 port of SCGCQ01856544) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01927583 port of SCGCQ01106982) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945574 port of SCGCQ01945551) 
 - storclio command not working to update FW on SATA disk(SCGCQ01963953 port of SCGCQ01918814) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01963954 port of SCGCQ01937410) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964173 port of SCGCQ01955389) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01966163 port of SCGCQ01892560) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01982925 port of SCGCQ01979483) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01985486 port of SCGCQ01893074) 
 - Enable iMR advanced debug dump(SCGCQ02035300 port of SCGCQ01873124) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02074659 port of SCGCQ02072353) 
 - HDET:Libmods-Boot device should be presented as /dev/sda in Linux operating system during installation and post installation	(SCGCQ02082198 port of SCGCQ02046182) 
 - HDET: Boot device should be presented as /dev/sda in Linux operating system during installation and post installation(SCGCQ02082199 port of SCGCQ02016712) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02085669 port of SCGCQ02045967) 
 - storclif /cx delete colinfo ? shows syntax error	(SCGCQ02124654 port of SCGCQ02124492) 
 - PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02128167 port of SCGCQ02119004) 
 - Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02142248 port of SCGCQ02140878) 
 - Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02145876 port of SCGCQ02140859) 
 - PERCCLI to support creation of VD with WB policy for PERC8 MR(SCGCQ01892550 port of SCGCQ01891650) 
 - MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+	(SCGCQ02139866 port of SCGCQ02066386) 
 - Libmod changes for SCGCQ02090770(SCGCQ02097658 port of SCGCQ02090770) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02075280 port of SCGCQ02072353) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.	(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli shows incorrect output for delete events command(SCGCQ02046875 port of SCGCQ02045816) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01979535 port of SCGCQ01979483) 
 - enhance warning message for personality switch indicating interruption could cause controller to be unstable(SCGCQ01892552 port of SCGCQ01892549) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"	(SCGCQ01906745 port of SCGCQ01889700) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01925211 port of SCGCQ01196785) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929137 port of SCGCQ01224857) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01963960 port of SCGCQ01923119) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01963964 port of SCGCQ01921258) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01965193 port of SCGCQ01961527) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965209 port of SCGCQ01949495) 
 - supported personalities has blank value	(SCGCQ01971366 port of SCGCQ01965370) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977028 port of SCGCQ01948579) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979617 port of SCGCQ01979599) 
 - WBSup abbreviation defined twice when running perccli /cX show profile(SCGCQ01995022 port of SCGCQ01993282) 
 - spell mistake in start diag operation failure(SCGCQ01998963 port of SCGCQ01998330) 
 - Proper message to be given on VD creation with wb option while Battery not connected/Failed(SCGCQ02028787 port of SCGCQ01972504) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02028810 port of SCGCQ02008676) 
 - Enable iMR advanced debug dump(SCGCQ02035289 port of SCGCQ02030908) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02085609 port of SCGCQ02084833) 
 - Flashing of Completeflash fails on Sea IT controller(SCGCQ02139848 port of SCGCQ02139780) 
 - Storcli: "Ctrl" legend not mentioned.(SCGCQ02150640 port of SCGCQ02146822) 
 - storcli -help missing the verbose option	(SCGCQ02160908 port of SCGCQ02158600) 
 - MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02168183 port of SCGCQ02165933) 
 - Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02179296 port of SCGCQ02174296) 
 - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180519 port of SCGCQ02180495) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.	(SCGCQ02047079 port of SCGCQ02024740) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - storcli faults for enclosure show command(SCGCQ01986423 port of SCGCQ01985815) 
 - storclio command not working to update FW on SATA disk(SCGCQ01922919 port of SCGCQ01918814) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964153 port of SCGCQ01955389) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01965185 port of SCGCQ01413253) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965210 port of SCGCQ01949503) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01966261 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01985558 port of SCGCQ01892560) 
 - Snapdump unsupported commands for HPE needs to be disabled(SCGCQ01996375 port of SCGCQ01985589) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02009848 port of SCGCQ01992461) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02011417 port of SCGCQ01761309) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02043788 port of SCGCQ02040783) 
 - Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02124488 port of SCGCQ02123789) 
 - Storcli: "completeflash" is listed in Windows help file.(SCGCQ02145743 port of SCGCQ02141931) 
 - Storcli: /c0 set ? lists bbu,mx,px and lnx commands.	(SCGCQ02145756 port of SCGCQ02136689) 
 - Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02145764 port of SCGCQ02136333) 
 - Help note 'page=[x]' needs update(SCGCQ02149062 port of SCGCQ02146823) 
 - Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02153948 port of SCGCQ02150924) 
 - Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02154721 port of SCGCQ02135526) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Aero (DBU PA2(SCGCQ02086670 port of SCGCQ02082460) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02079507 port of SCGCQ02078437) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all	(SCGCQ02047235 port of SCGCQ02040756) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Request to Disable DSW3(SCGCQ01903331 port of SCGCQ01896311) 
 - PERCCLI Support for EKMS(SCGCQ01904188 port of SCGCQ01902150) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01904340 port of SCGCQ01413253) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921529 port of SCGCQ01220901) 
 - Hide "set termlog" help contents from perccli(SCGCQ01935143 port of SCGCQ01923643) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01940869 port of SCGCQ01937410) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01945534 port of SCGCQ01940805) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01965393 port of SCGCQ01935697) 
 - Storcli shows wrong PD list sequence.(SCGCQ01971632 port of SCGCQ01967488) 
 - LD size not shown in GiB format in foreign import preview(SCGCQ01996370 port of SCGCQ01978978) 
 - Unable to switch to eHBA mode using a H745P Adapter(SCGCQ01998964 port of SCGCQ01990060) 
 - perccli show profile lists personality as JBOD instead of eHBA(SCGCQ01998966 port of SCGCQ01998328) 
 - Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101377 port of SCGCQ02101372) 
 - In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02116733 port of SCGCQ02115036) 
 - complete Lane WWID is not displayed(SCGCQ02145739 port of SCGCQ02145716) 
 - No "Rbld" legend during rebuild.	(SCGCQ02150634 port of SCGCQ02146819) 
 - Error message mismatch is seen for rttdump command on iMR Ventura controller.(SCGCQ02160907 port of SCGCQ02156483) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324)
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - Storcli shows wrong PD list sequence.(SCGCQ01977461 port of SCGCQ01967488) 
 - Migrate Failure case is not Branding compliant(SCGCQ02000716 port of SCGCQ01988402) 
 - StorCLI PH12: Retrieving topology details causes application crash in some scenario(SCGCQ02106192 port of SCGCQ02103217) 
 - Support FMP Images in UEFI Version of PERCCli(SCGCQ02116464 port of SCGCQ02078649) 
 - MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02116497 port of SCGCQ02114898) 
 - PH12 PA - StorCLI - 9310-8i IR FW download fails	(SCGCQ02121848 port of SCGCQ02121783) 
 - LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02139867 port of SCGCQ02085102) 
 - MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend	(SCGCQ02168256 port of SCGCQ02165944) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02079597 port of SCGCQ02035437) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Incorrect status displayed for resume copyback command.	(SCGCQ02075291 port of SCGCQ02062834) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01929892 port of SCGCQ01106988) 
 - Added new commands from StorCLI(SCGCQ01935296 port of SCGCQ01134166) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01964024 port of SCGCQ01923119) 
 - securesed autoconfig param should not be present for perccli help(SCGCQ01986879 port of SCGCQ01986831) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032582 port of SCGCQ02029410) 
 - Drives connected to active backplanes not showing the phy info in connector name	(SCGCQ02112425 port of SCGCQ02112424) 
 - Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02150630 port of SCGCQ02132024) 
 - Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02153950 port of SCGCQ02150921) 
 - Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02154755 port of SCGCQ02150651) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.	(SCGCQ02079601 port of SCGCQ01992461) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - Storcli: HPE serial number programming and display(SCGCQ02062635 port of SCGCQ01882984) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893381 port of SCGCQ01892288) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01930028 port of SCGCQ01141462) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01936895 port of SCGCQ01935697) 
 - Terminology change from " Data protection" to " Data integrity".(SCGCQ01940807 port of SCGCQ01827339) 
 - Libmods: Terminology change from " Data protection" to " Data integrity".(SCGCQ01943370 port of SCGCQ01827732) 
 - Incorrect colinfo output of Bad block count(SCGCQ01977457 port of SCGCQ01977443) 
 - StorCLI hangs when viewing controller in FreeBSD (MR7.8 is okay(SCGCQ01984543 port of SCGCQ01978824) 
 - Unified StorCLI : Help command of "Get flash" is not shown in generic help syntax(SCGCQ01985472 port of SCGCQ01985463) 
 - StorCLI show output shows Legends as BBU instead of EnergyPack.(SCGCQ01992007 port of SCGCQ01985587) 
 - Aero A0 UTP: StorCLI snapdump command needs to clarify new "On Demand" snapdump option(SCGCQ01995066 port of SCGCQ01993722) 
 - Shenandoah:StorCLI:Right click properties for released binary shown blank.(SCGCQ02000843 port of SCGCQ01988329) 
 - Smart Carrier Enclosure port info shown as "Multuipath"(SCGCQ02008273 port of SCGCQ01992087) 
 - MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json	(SCGCQ02116771 port of SCGCQ02112192) 
 - "Storcli /c# set jbod=on" shows success but does nothing	(SCGCQ02119067 port of SCGCQ02117219) 
 - Phyreset Fails on IT controllers	(SCGCQ02169305 port of SCGCQ02169242) 
 - Storcli stop erase needs an help file update	(SCGCQ02169308 port of SCGCQ02168895) 
 - Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02185911 port of SCGCQ02184862) 
 - Storcli connector display not matching with Aero board 9560-16i.	(SCGCQ02085681 port of SCGCQ02072448) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - PERCCLI Support for EKMS	(SCGCQ01904189 port of SCGCQ01903448) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911832 port of SCGCQ01886637) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915313 port of SCGCQ01222855) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915315 port of SCGCQ01227144) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ01998965 port of SCGCQ01998332) 
 - PH12 PA - StorCLI version not getting printed for show file command	(SCGCQ02116759 port of SCGCQ02105185) 
 - Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176697 port of SCGCQ02176681) 
 - With IT controller for set or reset with invalid phy is not showing error(SCGCQ02183510 port of SCGCQ02181823) 
	
EnhancementRequests:
 - Incorporating VMware constraints for PERCCLI VIB signing	(SCGCQ02190441) 
 - Migrating VMware 64 bit toolchain to 6.8.7-13394445(SCGCQ02190429) 
 - Create an event for DDF config clear failed event.(SCGCQ02173513) 
 -	(SCGCQ02162699) 
 - Snap Dump ClearAll Method logging event(SCGCQ02157359) 
 - API changes for a better presentation of Atlas to tools(SCGCQ02149380) 
 - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) 
 - Better error message for certain unmap operations(SCGCQ02111563) 
 - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change(SCGCQ02103973) 
 - MR Windows IOCTL Error codes to Application added to MR API(SCGCQ02103183) 
 - API changes for linkconfig interface	(SCGCQ02053671) 
 - API changes for NVMe speed and width changes	(SCGCQ02053667) 
 - Reword event log messages as it creates unnecessary panic.(SCGCQ02013675) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949495) 
 - Unified StorCLI : Adding component level download functionality to StorCLI(SCGCQ01940030) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01927541) 
 - snapdump support for host initiated snapdump	(SCGCQ01901158) 
 - Changes for disable least latency mode(SCGCQ01891451) 
 - Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01929656) 
 - MR_SAS_Unified_Libmods_7.10 Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01979597) 
 - Post firmware trace buffer at the time of driver load(SCGCQ01992779) 
 - Adding the spare details in the same volume creation(CONFIG_ADD DCMD(SCGCQ02008407) 
 - PSoC implementation in StorCLI by parsing PSoC image(SCGCQ02072160) 
 - Request to display the help for "show" and "set" for JBOD in PercCLI	(SCGCQ02160291) 
 - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) 
 - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) 
 - Enable iMR advanced debug dump(SCGCQ02030908) 
 - Unified StorCLI : ARM Windows support to StorCLI(SCGCQ01962294) 
 - Disabling RAID00 support	(SCGCQ01960420) 
 - HPE Shenandoah: Branding tool(SCGCQ01960295) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949503) 
 - Unified StorCLI : Allow SBR/SPD read and write using new CBB+SBR concatenated image(SCGCQ01927551) 
 - show complete Serial Number and Model Name for NVMe drive connected to IT controller(SCGCQ01927538) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01919655) 
 - Unified CLI - Command processor changes for handling invalid/tampered device id's for sea IT controllers(SCGCQ01891513) 
 - Add support to display PSOC version for Ventura IT controllers(SCGCQ02067300) 
 - set copyback command changes for cli(SCGCQ02148092) 
 - Unified StorCLI : ARM64 Windows support to StorCLI - LibMod changes(SCGCQ01963208) 
 - Shenandoah: Adding support bit check for delete snap dump(SCGCQ01944500) 
 - Enable iMR advanced debug dump(SCGCQ01873124) 
 - Unified StorCLI : PSoC read and write via Device read and write DCMD's in MR Operational case(SCGCQ01949521) 
 - Changes for disable least latency mode(SCGCQ01891442) 
 - Adding the spare details in the same volume creation (CONFIG_ADD DCMD(SCGCQ02008403) 
 - Unified StorCLI : Allow erase functionality on operational MR using CBB concatenated image(SCGCQ01927595) 
 - Unified CLI : Handling invalid/tampered controllers for sea controllers(SCGCQ01891484) 
 - Requesting StorCLIF to read MR FW from flash device and write it to a file. Similar to what IT FW support.(SCGCQ01631948) 
 - Add ability to field upgrade PSOC on HBA boards(SCGCQ01583214) 
 - DUal Image SUpport(SCGCQ01960287) 
 - Libmods: Porting HPE Shenandoah from Aero to 7.9	(SCGCQ01917263) 
 - Porting HPE Shenandoah from Aero to 7.9(SCGCQ01917172) 
 - Adding HPE specific help for storcli	(SCGCQ01935699) 


007.0816.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

defects:
  - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01824574 port of SCGCQ01824569) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01827604 port of SCGCQ01681538) 
 - Updating makefile and EFI's INF changes for ARM StorCLIO(SCGCQ01870684 port of SCGCQ01563125) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ02085925 port of SCGCQ01998332) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853370 port of SCGCQ01775616) 
 - (SCGCQ01775602 port of SCGCQ01814011)
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - Storcli shows incorrect output for delete events command	(SCGCQ02046875 port of SCGCQ02045816) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - Drive Size Display Miss Match In Storcli Show Output(SCGCQ02075280 port of SCGCQ02072353) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02097658 port of SCGCQ02096774) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01850374 port of SCGCQ01837932) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02047079 port of SCGCQ02024740) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02047235 port of SCGCQ02040756) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - show/set lane speed shows success when we are in SAS profile	(SCGCQ02079507 port of SCGCQ02078437) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - Aero (DBU PA2)(SCGCQ02086670 port of SCGCQ02082460) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01857450 port of SCGCQ01856544) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01825986 port of SCGCQ01824570) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01832791 port of SCGCQ01816927) 
 - Add interface in storecli that could get relearn complete status	(SCGCQ01850373 port of SCGCQ01848387) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/ eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02075291 port of SCGCQ02062834) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"	(SCGCQ02079597 port of SCGCQ02035437) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/ px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - Aero - LibMod changes for ER SCGCQ01813156 : Addition of Aero and Sea device id's and checkwords	(SCGCQ01853418 port of SCGCQ01813626) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02079601 port of SCGCQ01992461) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Add get VPD command support to StorCLI in OS environment	(SCGCQ01855067 port of SCGCQ01852603) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 - CSET: Checking in Libmod changes for defect SCGCQ02030652 - (SCGCQ02045948(SCGCQ02047884 port of ) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02085681 port of SCGCQ02072448)

EnhancementRequest:
- Updating ncurses library from 6.0 to 6.1(SCGCQ01836749) 
 - Command processor changes for Secure boot properties feature - SCGCQ01855473	(SCGCQ01855503) 
 - Adding secure boot properties to unified StorCLI	(SCGCQ01855473) 
 - Adding new MFI STAT - MFI_STAT_SECURE_BOOT_KEY_SLOTS_FULL 007.0711.0000.0000 for Lenovo(SCGCQ01865190) 

007.0713.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) 
 - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01556595) 
 - controller show all command is not listing the Battery information(SCGCQ01561689) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) 
 - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) 
 - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) 
 - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) 
 - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) 
 - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) 
 - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) 
 - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) 
 - Spell mistake in error message for hwdev command(SCGCQ01614972) 
 - Coverity defect fix for itctflash file(SCGCQ01616369) 
 - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) 
 - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) 
 - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) 
 - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) 
 - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) 
 - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) 
 - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) 
 - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) 
 - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) 
 - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) 
 - Help content for jbodx show unmap is not present(SCGCQ01790130) 
 - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - storclio command not working to update FW on SATA disk(SCGCQ01918814) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) 
 - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) 
 - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) 
 - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) 
 - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) 
 - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) 
 - Checking in VBAS compliation changes(SCGCQ01630324) 
 - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) 
 - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) 
 - Space need in the output for secure erase(SCGCQ01713604) 
 - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) 
 - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) 
 - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) 
 - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) 
 - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) 
 - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01735493) 
 - Storcli vib update fails across releases.(SCGCQ01761795) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) 
 - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) 
 - Removing the set/show of unmap on JBOD.(SCGCQ01817855) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) 
 - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) 
 - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) 
 - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01595640) 
 - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) 
 - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) 
 - Update help contents for jbod delete(SCGCQ01624605) 
 - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) 
 - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) 
 - Missing punctuation in Perccli delete config message(SCGCQ01698226) 
 - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) 
 - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) 
 - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) 
 - Drive Fw download Coverity fixes(SCGCQ01615074) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) 
 - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) 
 - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) 
 - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) 
 - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) 
 - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) 	
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) 
 - Updating the Diag results as per new API changes(SCGCQ01537255) 
 - Resource leaks,Uninitialized variables(SCGCQ01600311) 
 - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) 
 - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) 
 - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) 
 - Removal of ncurses references for linux makefile(SCGCQ01955544) 
  - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) 
 - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) 
 - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) 
 - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) 
 - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) 
 - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) 
 - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) 
 - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) 
 - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) 
 - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) 
 - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) 
 - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) 
 - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) 
 - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) 
 - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) 
 - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) 
 - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) 
 - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) 
 - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) 
 - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) 
 - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) 
 - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) 
 - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) 
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) 
 - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) 
 - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) 
 - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) 
 - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) 
 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) 
 - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) 
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) 
 - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) 
 - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) 
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) 
 - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) 
 - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) 
 - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) 
 - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) 
 - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) 
 - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) 
 - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) 
 - .(SCGCQ01571935 port of SCGCQ01325052) 
 - Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) 
 - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) 
 - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) 
 - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) 
 - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) 
 - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) 
 - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) 
 - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) 
 - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) 
 - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) 
 - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) 
 - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) 
 - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) 
 - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) 
 - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) 
 - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) 
 - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) 
 - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) 
 - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) 
 - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 
EnhancementRequests
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) 
 - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) 
 - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) 
 - Need Storcli support drive FW upgrade(SCGCQ01583217) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) 
 - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) 
 - Add a bit for atomic descriptor capable(SCGCQ01965047) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01583223) 
 - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) 
 - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) 
 - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) 
 - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) 
 - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) 
 - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 


007.0525.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects (16)
-.(SCGCQ01753405)
- Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033)
- Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315)
- Enclosure show status command gives success but nothing is shown.(SCGCQ01731280)
- One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763)
- Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927)
- Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612)
- Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548)
- Space need in the output for secure erase.(SCGCQ01713604)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Missing punctuation in Perccli delete config message.(SCGCQ01698226)
- Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265)
- non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272)
- DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443)
- WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279)
- Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752)
- perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719)
- storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990)
- State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444)
- Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355)
- storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816)
- Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795)
- storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493)
- Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849)
- Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269)
- "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017)
- controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704)
- Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749)
- Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493)
- Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354)
- PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418)
- Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616)
- Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223)
- Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972)
- StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602)
- Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983)

EnhancementRequests (30)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730)
-.(SCGCQ01593479)
-.(SCGCQ01761309)
- displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528)
- Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603)


0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence
-------------------

Defects (75)
- Profile Mgmt API Changes.( SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- Enable WB support via API.(SCGCQ01405242)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979)
- Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940)
- storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171)
- Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396)
- Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401)
- Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745)
- Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131)
- Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420)
- Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852)
- Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910)
- Detailed help contents were not present for most of the IT download options..(SCGCQ01483760)
- Spelling errors in the "/cx restart" command..(SCGCQ01486415)
- Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052)
- CLI help does not reflect the new command to create an ePD.(SCGCQ01639583)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- Instance Validation is failing for mentioned commands..(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447)
- Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990)
- PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588)
- Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580)
- Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694)
- PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920)
- PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062)
- Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041)
- Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421)
- Checking in VBAS compliation changes.(SCGCQ01630324)
- PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798)
- Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240)
- Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214)
- MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582)
- Schema addition for "show file=" command.(SCGCQ01461209)
- PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593)
- MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562)
- PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762)
- Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845)
- Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344)
- Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670)
- OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785)
- Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797)
- Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- Incorrect help description for erase and download completeflash commands.(SCGCQ01470263)
- Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802)
- Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833)
- Check for supported pages for firing drive SCSI commands.(SCGCQ01474325)
- No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900)
- IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753)
- Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446)
- Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195)
- Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334)
- Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821)
- UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749)


EnhancementRequests (174)
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType..(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- JSON schema for Drive level commands.(SCGCQ01445435)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
-.(SCGCQ01389581)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- Removing the NMR storcli commands from storcli..(SCGCQ01445268)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
- Removing the NMR storcli commands from storcli..(SCGCQ01445418)
-.(SCGCQ01428114)
-.(SCGCQ01423509)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987)
- Add NVMe device related changes.(SCGCQ01034678)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986)
- Add boot drive selection support in Stor-CLI.(SCGCQ01445896)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424)
-.(SCGCQ01466805)
- StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954)
- StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799)
- Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308)
- Add support for IT Firmware images and IT Completeflash images to "show file=" command.(SCGCQ01436882)

CSETActivities (57)
- StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445)
- Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174)
- Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483)
- Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457)
- Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170)
- Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237)
- SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496)
- Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245)
- This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717)
- Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154)
- Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920)
- Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496)
- Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780)
- Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929)
- Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698)
- Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009)
- Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154)
- storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595)
- Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709)
- Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360)
- Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764)
- Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886)
- Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526)
- Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435)
- Updating readme file(SCGCQ01294583 port of SCGCQ01294570)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453)
- Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412)
- Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234)
- Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605)
- Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562)
- Commands "/call/all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703)
- Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628)
- Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447)
- Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256)
- Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552)
- Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578)
- Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900)
- DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749)
- syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675)
- controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689)
- Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481)
- Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460)
- Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156)
- Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214)
- CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640)
- Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618)
- Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793)
- Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255)
- Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754)

0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------
fixes:
- Profile Mgmt API Changes.(SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846)
- Fixing Error Handling issues and Resource leak.(SCGCQ01319395)
- Fix for Libmod files having potential loop errors.(SCGCQ01320336)
- Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003)
- EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452)
- Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604)
- Updated the Help.(SCGCQ01375059)
- controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816)
- Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238)
- storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690)
- Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425)
- Fixing out of bounds in libmods.(SCGCQ01385430)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177)
- Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543)
- PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511)
- Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756)
- Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011)
- Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239)
- Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897)
- Need to handle FW return code change for profile management success case.(SCGCQ01307320)
- Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405)
- PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477)
- Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749)
- CLI reports failure when issuie DPM commands.(SCGCQ01333085)
- PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041)
- Fixing unchecked return values.(SCGCQ01385377)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610)
- Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922)
- LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583)
- Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764)
- Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948)
- Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222)
- This is a syntactical error where a comma was added.(SCGCQ01414744)
- Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208)
- Instance Validation is failing for mentioned commands.(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
- StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018)
- IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046)
- Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219)
- Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438)
- Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771)
- Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
- PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757)
- Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407)
- Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042)
- CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639)
- Removing the memory leaks in dequelog command.(SCGCQ01411544)
- Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758)
- Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934)
- Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Fixing Out of Bounds access and Resource leak.(SCGCQ01304875)
- Inconsistencies between the applications for manage link speed.(SCGCQ01389856)
- Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106)
- Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- StorCLI: Spindown help syntax is misleading.(SCGCQ01421610)
- Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
- StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900)
- Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891)
- Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748)
- Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890)
- Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943)
- Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289)
- StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557)
- Removing the NMR command for setting SCAPVPD.(SCGCQ01389451)
- Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749)

EnhancementRequests:
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType.(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
-.(SCGCQ01421997)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793)
- RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354)
- Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469)
- Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465)
- List pending profile details of the controller.(SCGCQ01346308)
-.(SCGCQ01291037)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- always print StorCLI version information at beginning/top of output.(SCGCQ01396733)
- StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177)
- New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
-.(SCGCQ01428114)
- Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646)
- Add NVMe device related changes.(SCGCQ01034678)
- Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301)
- Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079)
- Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)

CSETActivities:
- StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018)
- MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830)
- Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790)
- MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315)
- MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798)
- Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785)
- SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496)
- Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610)
- Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900)
- CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 )
- Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789)
- Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152)
- Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673)
- Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381)
- Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320)
- MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757)
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529)
- MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520)
- Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274)
- MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453)
- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843)
- Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891)
- CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 )
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177)
- Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604)
- Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843)
- Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152)
- C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830)
- Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495)
- Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145)
- Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484)
- [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914)
- Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728)
- MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756)
- MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493)

0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
 - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536)
 - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913)
 - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948)
 - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629)
 - Code clean up in libmods and sysefi files are added(SCGCQ00359998)
 - Storcli is returning error with show(SCGCQ00360040)
 - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814)
 - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216)
 - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717)
 - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455)
 - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522)
 - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097)
 - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248)
 - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622)
 - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735)
 - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000)
 - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155)
 - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735)
 - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364)
 - portings of AdpRestart command(SCGCQ00378135)
 - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828)
 - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104)
 - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303)
 - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789)
 - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832)
 - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350)
 - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610)
 - SWR_1.34(SCGCQ00442652)
 - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502)
 - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583)
 - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843)
 - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560)
 - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201)
 - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579)
 - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935)
 - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835)
 - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123)
 - Storcli : unable to set patrol read delay(SCGCQ00645195)
 - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324)
 - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742)
 - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131)
 - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171)
 - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192)
 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505)
 - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647)
 - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770)
 - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178)
 - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183)
 - Adapters are not listed in sorted order.(SCGCQ00759969)
 - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398)
 - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752)
 - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663)
 - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712)
 - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243)
 - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789)
 - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882)
 - "cpybck" help is not coming in Legends(SCGCQ00784808)
 - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400)
 - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232)
 - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374)
 - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394)
 - .(SCGCQ00800878)
 - Deallocation of the same memory more than once(SCGCQ00802031)
 - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588)
 - Out-of-bounds access and array delete misuse(SCGCQ00804680)
 - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547)
 - Not able add new VD in Drive Group(SCGCQ00813314)
 - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939)
 - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049)
 - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299)
 - storcli /call show all fails with "command invalid"(SCGCQ00830269)
 - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342)
 - Profile Mgmt API Changes(SCGCQ00883008)
 - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417)
 - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738)
 - The code had events with repetitive ID and some structures clashing(SCGCQ00948535)
 - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835)
 - 800C error when execting Get MFC default function(SCGCQ01037840)
 - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936)
 - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284)
 - No ISE Capable field(SCGCQ01148693)
 - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175)
 - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698)
 - Fixing Resource leaks(SCGCQ01205356)
 - resource validation before de referencing(SCGCQ01206104)
 - Fixing resource leaks in libmods(SCGCQ01208044)
 - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393)
 - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414)
 - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473)
 - Fix for resource leak in system config show(SCGCQ01210133)
 - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415)
 - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383)
 - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923)
 - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217)
 - NVMe PD SMART DATA shows all 0's(SCGCQ01236052)
 - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715)
 - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381)
 - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687)
 - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688)
 - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928)
 - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421)
 - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632)
 - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445)
 - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336)
 - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979)
 - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883)
 - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094)
 - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474)
 - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620)
 - Some sparc structures missing for storcli.(SCGCQ00504585)
 - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761)
 - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658)
 - storecli reports wrong size on 3000MB VD(SCGCQ00644545)
 - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962)
 - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672)
 - Add support bits for uneven-span and SSHA support(SCGCQ00755063)
 - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101)
 - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924)
 - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290)
 - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959)
 - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385)
 - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937)
 - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714)
 - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759)
 - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347)
 - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363)
 - Storcli errors are printing in a different line.(SCGCQ00771626)
 - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302)
 - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332)
 - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577)
 - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800)
 - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357)
 - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202)
 - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761)
 - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393)
 - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335)
 - Resource leak(SCGCQ00804745)
 - .(SCGCQ00811452)
 - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672)
 - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205)
 - Fix for profile management support check bit(SCGCQ01208103)
 - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411)
 - Unified Storcli: Fixing resource leak issues(SCGCQ01209413)
 - SAS3.5 Ventura(SCGCQ01219196)
 - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153)
 - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169)
 - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376)
 - Need to handle FW return code change for profile management success case(SCGCQ01307320)
 - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263)
 - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644)
 - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663)
 - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978)
 - storcli /c0 show is not listinf SWR controller(SCGCQ00454971)
 - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116)
 - Raptor Galaxy : Storcli(SCGCQ00475562)
 - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981)
 - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771)
 - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763)
 - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073)
 - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800)
 - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416)
 - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775)
 - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174)
 - storelib header file changes porting(SCGCQ00609942)
 - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023)
 - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969)
 - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070)
 - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000)
 - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187)
 - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806)
 - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918)
 - Missing the Display of the property temperatureCtrl.(SCGCQ00792264)
 - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760)
 - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336)
 - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206)
 - Memory not freed which can cause leak(SCGCQ00804554)
 - Varailble need to be freed before returning in all failure case(SCGCQ00804650)
 - IDA show incorrect RAID controller type information(SCGCQ00806966)
 - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197)
 - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372)
 - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111)
 - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464)
 - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723)
 - Removing Unused and logically dead code in storcli(SCGCQ01204045)
 - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492)
 - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685)
 - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083)
 - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
 - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332)
 - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100)
 - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043)
 - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956)
 - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370)
 - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287)
 - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672)
 - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181)
 - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862)
 - CPLD(SCGCQ00787705)
 - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233)
 - rlListPtr is not handled properly in failure case(SCGCQ00796227)
 - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392)
 - LDViewMirror is giving segmentation fault(SCGCQ00830435)
 - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758)
 - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321)
 - Checking in compilation error for Libmods(SCGCQ00919973)
 - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356)
 - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055)
 - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407)
 - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101)
 - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553)
 - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709)
 - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745)
 - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950)
 - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070)
 - debug prints are present when issuing /co/eall show(SCGCQ00475815)
 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543)
 - Verify StorCLI warns on destructive operations(SCGCQ00712982)
 - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584)
 - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691)
 - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358)
 - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200)
 - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211)
 - Incorrect sizeof expression in dcmdprm(SCGCQ00793354)
 - Non-array delete for objects in rmdatamf(SCGCQ00793361)
 - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420)
 - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663)
 - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
 - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736)
 - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583)
 - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096)
 - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306)
 - PD related information missing for NVMe drives(SCGCQ01126564)
 - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365)
 - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854)
 - StorCLI(SCGCQ01274554)
 - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911)
 - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070)
 - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665)
 - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107)
 - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008)
 - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605)
 - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
 - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402)
 - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205)
 - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334)
 - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342)
 - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311)
 - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117)
 - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368)
 - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844)
 - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353)
 - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082)
 - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437)
 - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721)
 - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236)
 - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289)
 - Help for Compare linkspeed is not complete(SCGCQ01275454)
 - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037)
 - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491)
 - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067)
 - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426)
 - Libmod changes to support profile management(SCGCQ01048228)
 - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627)
 - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876)
 - Ventura PH3(SCGCQ01253012)
 - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455)
 - coverity removing out of bounds reads from code(SCGCQ01280460)
 - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999)
 - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085)
 - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234)
 - Resource leak in VdDataMf scanPartitions(SCGCQ00793363)
 - Storcli can't create AHCI LDs(SCGCQ00897637)
 - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676)
 - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024)
 - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214)
 - Detailed help missing for IT erase commands(SCGCQ01275474)
 - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671)
 - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453)
 
Enhancement
 
 - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167)
 - New fault code for routine synchronous reset(SCGCQ01264142)
 - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358)
 - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050)
 - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414)
 - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228)
 - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796)
 - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215)
 - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613)
 - API changes for CR55(SCGCQ01222700)
 - API change for Simplified RAID10 Creation(SCGCQ01222698)
 - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406)
 - API changes for PR SCGCQ01139678(SCGCQ01215334)
 - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 - API changes for PR SCGCQ01127742(SCGCQ01203751)
 - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 - MR 6.12(SCGCQ01146597)
 - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251)
 - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344)
 - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627)
 - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969)
 - MPI 2.5: Add new connector types(SCGCQ01085073)
 - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360)
 - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162)
 - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885)
 - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208)
 - MPI 2.5: update copyright info(SCGCQ00728066)
 - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829)
 - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820)
 - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175)
 - Add type BIOS for HashImageType.(SCGCQ00566306)
 - Identify physical location of a target device(SCGCQ00523879)
 - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817)
 - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293)
 - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819)
 - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437)
 - Allow Protection Information bit for IR Volume Create(SCGCQ00385306)
 - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551)
 - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271)
 - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270)
 - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266)
 - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260)
 - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506)
 - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383)
 - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439)
 - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131)
 - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055)
 - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759)
 - MPI 2.6: SOP Encapsulated request(SCGCQ00264755)
 - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183)
 - Libmods changes for EFI support for Unified storcli(SCGCQ00923719)
 - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101)
 - OEL Support for SPARC(SCGCQ00787923)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007)
 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477)
 - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399)
 - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735)
 - MPI 2.6: add IO Unit Control Request(SCGCQ00345258)
 - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272)
 - MPI 2.6: Enclosure Management(SCGCQ00345273)
 - Device Info field for PCIe devices(SCGCQ00353339)
 - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843)
 - MPI 2.6: new family values for ProductID fields(SCGCQ00360952)
 - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600)
 - Modified address space bits(SCGCQ00397136)
 - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563)
 - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568)
 - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572)
 - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577)
 - MPI 2.6: Add NVMe SGL support(SCGCQ00398256)
 - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541)
 - MPI 2.6: System Interface Register Set update(SCGCQ00464402)
 - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292)
 - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998)
 - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281)
 - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070)
 - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869)
 - MPI 2.6: Add new FLASH region types(SCGCQ00619371)
 - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271)
 - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957)
 - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527)
 - MPI 2.6: Extend Task Management(SCGCQ00686666)
 - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177)
 - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600)
 - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389)
 - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088)
 - MPI 2.6: add PCI Device ID's(SCGCQ00828497)
 - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588)
 - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827)
 - MPI 2.6: Update Flash Signature.(SCGCQ00852831)
 - profile management API(SCGCQ00867953)
 - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169)
 - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328)
 - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262)
 - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740)
 - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256)
 - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336)
 - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213)
 - MPI 2.6: Remove all SOP references(SCGCQ00925839)
 - Change library name to SLIT(SCGCQ00933175)
 - Ventura: de-feature AHCI(SCGCQ00941620)
 - MPI 2.6: Remove all AHCI references(SCGCQ00948258)
 - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955)
 - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638)
 - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619)
 - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104)
 - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930)
 - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826)
 - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027)
 - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687)
 - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473)
 - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741)
 - mega api changes for ibuttonless PR(SCGCQ01059740)
 - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009)
 - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374)
 - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821)
 - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340)
 - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549)
 - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837)
 - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839)
 - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127)
 - MPI 2.6: Add new clean tool options(SCGCQ01141732)
 - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583)
 - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725)
 - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092)
 - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367)
 - MPI 2.5: Signed images for FWDownload(SCGCQ00469990)
 - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512)
 - Display the Storelib version in the show command.(SCGCQ01286063)
 - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457)
 - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496)
 - Add support to allow Device names greater than 107(SCGCQ01039328)
 - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636)
 - Enable SED on JBOD(SCGCQ00755527)
 - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230)
 - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051)
 - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474)
 - Implemented the diag results to print on console(SCGCQ00525321)
 - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742)
 - MWCLI. Add HA support into storcli(SCGCQ00352120)
 - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668)
 - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607)
 - Add NVMe device related changes(SCGCQ01034678)
 - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665)
 - Complete 240VD support for utilities(SCGCQ00693042)
 - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287)
 - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311)
 - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793)
 - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715)
 - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821)
 - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146)
 - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204)
 - UDK Support for EFI(SCGCQ00795150)
 - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171)
 - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872)
 - Provide a way to enable or disable 512E using Applications(SCGCQ00351234)
 - Refer attached design doc(SCGCQ00349599)
 - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)
 - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050)
 - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217)
 - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344)
 - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473)
 - RRB 71(SCGCQ00750164)
 - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081)
 - SED/FDE changes for storcli Synchro(SCGCQ00632240)
 - ASD- StorCLI(SCGCQ00467863)
 - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209)
 - PERC 10 WIndows Support(SCGCQ01213160)
 - PERC 10 WIndows Support(SCGCQ01213157)
 - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080)
 - Megacli/storcli support for lmrc driver(SCGCQ00433703)
 - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093)
 - Uneven span support is added in StorCLI.(SCGCQ00349548)
 - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391)
 - Add EFI support for the manufacturing command to program.(SCGCQ01191095)
 - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216)
 - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476)
 - Monitoring Drive performance and predictive failure(SCGCQ00817977)
 - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118)
 - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237)
 - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987)
 - Functionality to extract field value from new API changes(SCGCQ00794841)
 - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815)

0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.

1.20.20 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227)
- Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335)
- Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866)
- Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811)
- Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074)
- Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438)
- Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663)
- Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140)
- Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401)
- Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258)
- Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358)
- Fixed an issue where storcli does not display description on command success - (SCGCQ01023973)
- Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081)
- Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945)
- Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534)
- Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430)
- Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535)
- Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218)
- Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102)
- Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484)
- Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534)
- Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745)
- Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757)
- Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895)
- Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068)
- Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105)
- Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314)
- Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646)
- Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899)
- Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101)
- Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120)
- Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669)
- Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997)
- Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082)
- Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011)
- Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071)
- Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117)
- Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416)
- Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387)
- Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154)
- Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907)
- Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447)
- Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139)
- Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493)
- Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500)
- Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028)
- Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669)
- Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536)
- Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554)
- Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode  - (SCGCQ01043063)
- Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322)
- Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608)
- Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994)
- Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298)
- Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300)
- Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088)
- Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805)
- Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035)
- Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084)
- Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706)
- Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613)
- Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775)
- Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973)
- Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830)
- Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940)
- Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786)
- Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464)
- Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466)
- Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876)
- Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415)
- Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985)
- Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968)
- Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027)
- Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756)
- Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306)
- Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841)
- Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876)
- Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525)
- Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798)
- Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620)
- Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204)
- Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274)
- Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667)
- Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604)
- Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055)
- Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533)
- Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614)
- Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474)
- Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758)
- Fixed an issue where some commands may not report success on success - (SCGCQ01050695)
- Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241)
- Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116)
- Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773)
- Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500)
- Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378)
- Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493)
- Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205)
- Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864)
- Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540)
- Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766)
- Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178)
- Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305)
- Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482)
- Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514)
- Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493)
- Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642)
- Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528)
- Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477)
- Fixed an issue where installaton of storclio may fail - (SCGCQ00952422)
- Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981)
- Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790)
- Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315)
- Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178)
- Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865)
- Fixed an issue where EPD details may not show in "show all" command  - (SCGCQ00921937)
- Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624)
- Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489)
- Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330)
- Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837)
- Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484)
- Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697)
- Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461)
- Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597)
- Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760)
- Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891)
- Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993)
- Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617)
- Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault"  - (SCGCQ01020010, Port of SCGCQ01019547)
- Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212)
- Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145)
- Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101)
- Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181)
- Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177)
- Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789)
- Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable  - (SCGCQ01143941, Port of SCGCQ01026187)
- Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307)
- Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download  - (SCGCQ01110108, Port of SCGCQ00934755)
- Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211)
- Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584)

Enhancements:
- Added the personality change command was not present - (SCGCQ00850610)
- Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220)
- Added multipath support in EPD configuration options - (SCGCQ01015758)
- Added additional CPU support on EFI platform - (SCGCQ01026250)
- Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304)
- Added personality change features - (SCGCQ01111930)
- Added VF-queue depth mode settings - (SCGCQ00907072)
- Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320)
- Added Secure Erase support to JBOD and System drives - (SCGCQ00929757)
- Added a JBOD entity for various operations - (SCGCQ01047229)
- Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064)
- Added more specific error messages in some circumstances - (SCGCQ00920034)
- Added new compilation environment and makefiles - (SCGCQ00920058)
- Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739)
- Added support for drive microcode update Modes E and F - (SCGCQ01047223)
- Added code to display JBOD personality - (SCGCQ01146775)
- Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338)
- Added new erase type called Crypto - (SCGCQ01050618)
- Added new command to set the multiInit EPD parameter - (SCGCQ01080273)
- Added support for drive microcode update through parallel loading - (SCGCQ01024964)
- Added support for EPD creation - (SCGCQ00887664)
- Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414)


1.18.11 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705)
- Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785)
- Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612)
- Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196)
- Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339)
- Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620)

Enhancements:
- Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662)
- Added the support to set and clear the transport on a DG (SCGCQ00920046)
- Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318)
- Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795)
- Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030)
- Provide a more descriptive port enumeration (SCGCQ00854620)
- Add support to enable/Disable of Large IO Support (SCGCQ00894644) 

1.16.14 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617)
- Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176)
- Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715)
- Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755)

1.16.10 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617)
- Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470)
- Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914)
- Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143)
- Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429)
- Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770)


1.14.12 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Incorporated StorCLI MegaRAID 6.6 stream

Enhancements:
- Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171)
- Added consistent sorting of controllers using bus, device, function (SCGCQ00696872)
- Added ability to enable or disable 512e support (SCGCQ00351234)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527)
- Added ability for VMWare version to be run from any directory (SCGCQ00642230)
- Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477)
- Added ability to create a RAID00 (SCGCQ00350668)
- Added ability to display the Patrol Read Start Time (SCGCQ00564474)
- Added learn cycle progress information in show learn command (SCGCQ00644984)
- Added support for uneven spans (SCGCQ00349548)
- Added support for lmrc driver (SCGCQ00433703)
- Added 240 Virtual Drive support (SCGCQ00693042)
- Improved Punctured Block logging (SCGCQ00342399) 

1.12.15 - Moderate Impact/Low Probability of Occurrence
-------
Fix(es):
 - Prevent storCLI from allowing users to enable JBOD mode on
   controllers that do not support JBOD mode.
 - Updated CACHEBYPASS command to line up with user expectation.  When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass.

1.07.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M1215 SAS/SATA Controller
Fix(es):
 - Fixed an issue where segmentation faults may occur in Linux.
 - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS.
 - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying.

1.04.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M5210e and ServeRAID M5210
Fix(es):
 - Fixed an issue where a command failure results in subsequent commands and actions failing.
 - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR.
 - Added help file for for storcli /cx/dx set security
 - Fixed an issue where the "show ctrlcount help" command is not displaying properly.
 - Fixed an issue where a failure is displayed in the output for querying dimmer switch information.
 - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM.
 - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives.
 - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed.
 - Synced the pause pr command with show pr command to show correct PR Current State.
 - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property.

1.03.11 - Initial release
-------





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2022 Lenovo. All rights reserved