Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SD530 (7X21)
Targeted Operating System: RHEL8.7
YUM Repository Build Date: 2023_10_11

YUM Repository Release Version: SIAgile23-1

Device:
ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port PCIe Ethernet Adapter (GP servers) Part Number: 4XC7A08295
Feature Code: AUKX
PCIe Sub Vendor ID: 0x8086
PCIe Sub Device ID: 0x4003


Release History:

Release Change History Documents

Intel Networking Adapter/Device Linux Firmware




===========================================================================
Intel v28.0 Network FW Update Release for Linux
Release date = 02/16/2023
Package Version: net.e800.da2.pcie-4.22-1.3357.0-4
===========================================================================

CONTENTS
________

1.0  Change history
2.0  Web information and support phone Number
3.0  Notices and trademarks
4.0  Disclaimer


1.0  Change history
___________________

This FW update package supports Lenovo E810 Clifton Channel dual port SFP product ONLY.

This release includes the following updates:
============================================
Versions:

1) The following E810 images are at NVM 4.22 level.
-----------------------------------------------------------------------------------
           Device                  Boot ROM (Option ROM)  Firmware (Etrack ID)
-----------------------------------------------------------------------------------
    ThinkSystem E810-DA2 PCIe      1.3357                 80019449

2) NVMUPDATE tool updated to 1.39.32.6 to support new config version.

New features:
  - Support RHEL8.7/9.1, ESXi 8.0

  - OROM update support in Recovery mode

    Description:
    With this implementation, the NVM host update flow in recovery mode
    should be the same as in the operational mode.

  - Defines the IID (Instance IDs) field in the NC-SI packet’s header,
    which is used to match responses to requests and to differentiate
    between new and retried commands.

    Description:
    According to the spec, If the IID of the current command is the same as
    the previous command’s IID, the command is a "Retried Command" and the
    FW shall return the response of previous command (should be done
    without re-executing the command). When the IID is different than from
    the previous command, the command is executed.

    The NC-SI spec is unclear on if the incoming commands IID is compared
    to the IID of the previous command received on the same channel,
    package or device. This feature defines a transfer to maintaining a
    single buffer for the last NC-SI command received on the device per
    transmitting interface.

  - Add FC-FEC(CL74) support with optical transceiver 25G-SR

  - NVMUpdate - only access devices from config file

    Description:
    The affected component shall only access devices (read/write flash or
    registers) listed in config file that match the following criteria:
        * if device in config file contains: DEVICE and VENDOR all devices
          with specified device ID and vendor ID will be accessed;
        * if device in config file contains: DEVICE, VENDOR, SUBDEVICE,
          SUBVENDOR all devices with specified 4partID will be accessed,
        * if device in config file contains: DEVICE, VENDOR, SUBDEVICE,
          SUBVENDOR, REVISION all devices with specified 4partID and
          specific revision will be accessed.

    Device not listed in config file (do not match the criteria above)
    shall be marked as "Update not available' in interactive mode.

  - NVMUpdate - OROM update in recovery

    Description:
    If the device is in recovery mode and has the capability of supporting
    for OROM update in recovery mode. it can be updated OROM either from
    NVM image or from separate file (FLB).

  - RoCEv2 LAG

  - FEC auto-detect for CVL LR/SR mode

    Description:
    Only valid FEC modes will be attempted based on the media and PHY type.

  - Enable hardware arbitration

  - IPS: 00675913 - FEC Configuration through UEFI HII for 25G CVL adapters


Bug fixes:
  - IPS: 00796141 - E810 fails to link with 10/25Gb SFP28 connect to
    adapter and 10Gb SFP+ connected

    Description:
    Connect Lenovo 10/25Gb SFP28 to E810, Lenovo 10Gb SFP+ to switch (CISCO 9K)
    Link fails to come up.
    Fix:
    Change the preserved "inkDefaultOverridess"ields in the NVM image so
    that the settings in the NVM images make the firmware to try all the
    FEC modes during the link training.

  - IPS: 00736066 - [PA_IO Agile-Sprint202209_BDC_Storage_SR655] E810-DA2
    OCP ShareNIC cannot obtain DHCP IP under SR655

    Description:
    BMC failed getting an IP address on the sharenic port of E810-xxvDA2
    OCP via DHCP

    Fix:
    Use proper packageID SDP settings for SDP0 and SDP1

  - IPS: 00735574 - [PA_QUR 22C_BDC_SDV_FW_AMD1P_UEFI][RMK-5883]E810-DA4
    OCP Ethernet Adapter cannot obtain DHCP IP

    Destination:
    E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP.

    Fix:
    In implementation, use different variables to identify VSI in different
    context.

  - Both ports are loosing link randomly after dcb-map change

    Destination:
    The E810 adapter might experience an adapter-wide reset (all ports)
    when the DCBx willing configuration change (in firmware managed mode)
    propagated from the switch removes a TC that was RDMA enabled. This
    typically occurs when removing a TC associated with UP0 because it’s
    the default UP that RDMA based it’s configuration on. The reset results
    in a temporary loss in connectivity as the adapter re-initializes.

    Fix:
    FW changes along with changes in SW to allow for RDMA to disable
    QueueSets before suspending the removed TCs from the scheduler tree.


Release net.e800.da2.pcie-4.01-1.3282.0-10 includes the following updates:
=============================================================================
New features:
  - Support Windows 11
  - Support RHEL8.6/9.0, SLES 15SP4
  - Support scalable IOV feature (S-IOV) on the 4th Gen Intel® Xeon®
    Scalable Processor with the following drivers and OS:
    o ice 1.9.11 or later
    o iavf 4.5.3 or later
    o RHEL 7.9 and 8.5
    o SLES 12.5 and 15.3
    Note: Please refer to document for more details.


Bug fixes:
  - IPS: 00665409 - [IO_Tatlow_BBFV[UEFI] Intel E810-DA2 PCIE Ethernet
    Adapter changes do not take effect in network device.

    Description:
    During POST, in UEFI setup, set "Active Physical Functions" to "PF0"
    and save. However, it will still be set to "All" after reboot.

    Fix:
    Added a check to ensure only PF0 is used during HII value set.

  - IPS: 00673260 - E810 OCP adapter fails to link on D-Link switch but
    E810 PCIe adapter is able to establish link

    Description:
    With the same setup, E810 PCIe adapter links up, but E810 OCP adapter
    can't link up.

    Fix:
    Added new section in NVM to match the requirement and bring up link
    correctly.

  - IPS: 00688647 - BSOD seen on E810 ICEA driver when using SRIOV/RDMA

    Description:
    A customer has SR645 servers in a cluster running Windows 2019 Hyper-V.
    with SRIOV and RDMA. Randomly the server crashes with a BSOD.

    Fix:
    Updated driver to use correct lock and set correct status of queues in
    passive level thread


  - IPS: 00711180 - E810-DA2 has no Share NIC feature

    Description:
    No Shared option and only Dedicated in the field of Network Interface
    Port.

    Fix:
    Uses correct packageID definition in NVM image.


2.0 Web Sites and Support Phone Number
______________________________________

  o  You can download new and updated files for Lenovo products from the Lenovo
     Web site:

     http://datacentersupport.lenovo.com/

  o  With the original purchase of an Lenovo hardware product, you have access to
     extensive support coverage.  During the Lenovo hardware product warranty
     period, you may call the Lenovo HelpCenter for hardware product assistance
     covered under the terms of the Lenovo hardware warranty.


3.0 Trademarks and Notices
__________________________

  Lenovo is a registered trademark of Lenovo Corporation in the United States
  and other countries.

  Intel is a registered trademark of Intel Corporation in the United States
  and other countries.

  Linux is a registered trademark of Linus Torvalds in the United States and
  other countries.

  Other company, product, and service names may be trademarks or service marks
  of others.


4.0 Disclaimer
______________

  THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.
  Lenovo DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED,
  INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS
  FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE
  INFORMATION IN THIS DOCUMENT.  BY FURNISHING THIS DOCUMENT, Lenovo
  GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS.

  Note to U.S. Government Users -- Documentation related to
  restricted rights -- Use, duplication or disclosure is subject
  to restrictions set forth in GSA ADP Schedule Contract with
  Lenovo Corporation.






Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2023 Lenovo. All rights reserved

Intel Networking Adapter/Device RHEL 8 Driver




Intel Linux device drivers package update

Intel E810 Device Driver ice for RHEL8
Driver version 1.11.14

Intel X710, XXV710, and X722 Device Driver i40e for RHEL8
Driver version 2.22.18

Intel X520, X540, and X550 Device Driver ixgbe for RHEL8
Driver version 5.18.11

Intel I210, I340, I350 Device Driver igb for RHEL8
Driver version 5.13.16

This release supports RHEL 8.6 and 8.7.


Change History:

This update package contains the Intel Linux Ethernet device drivers.

Change information from previous release:

Driver     This release level     Previous release level
======     ==================     ======================
ice        1.11.14                1.9.11
i40e       2.22.18                2.20.12
ixgbe      5.18.11                5.16.5 
igb        5.13.16                5.11.4
irdma      1.11.58                1.9.30


This release supports all Intel Ethernet products across Lenovo ThinkSystem, ThinkAgile, System x,
and ThinkServer server platforms.


For installation instructions, see the Install Tip file which is provided
in the downloaded software package.
NOTE:  This document is designed to be cumulative.  The current version
is appended to the previous version(s).

==========================================================================
Severity Definitions:
  Critical:   Unable to use the solution resulting in a critical impact to
              operations. Includes high severity vulnerabilities.
  Suggested:  The solution can be used with some functional restrictions
              resulting in minimal impact to business. Includes medium and
              low severity vulnerabilities.
  Initial:    Initial release of the solution.
==========================================================================

==========================================================================
Version [net-28.0-0], Build ID [28.0-0]
Release date:   [02/16/2023]
==========================================================================

--------------------------------------------------------------------------
1.0 Overview
--------------------------------------------------------------------------

List products and OS Versions supported with this version of the update as
appropriate.

Supported configurations can be found on the Lenovo Operating System
Interoperability Guide at the following website:
https://lenovopress.com/osig


--------------------------------------------------------------------------
2.0 Prerequisites and dependencies
--------------------------------------------------------------------------
  none

--------------------------------------------------------------------------
3.0 Security Fixes
--------------------------------------------------------------------------
  FIX:
  None

  Security incident: LEN-xxxx


--------------------------------------------------------------------------
4.0 Other Fixes
--------------------------------------------------------------------------
  FIX:

- This release includes updated igb, ixgbe, i40e and ice drivers for RH8 support.


--------------------------------------------------------------------------
5.0 Enhancements
--------------------------------------------------------------------------
  ENHANCEMENT:
  

- Latest igb, ixgbe, i40e and ice drivers for supporting RHEL 8.6 and 8.7. 

- This release is with latest Red Hat RPM packaging.

- This build includes linkage support for SAP HANA platform.

- Packaged with latest Lenovo Linux device drivers packaging spec SLDPK 1.25.

- SUP package name is added with "net-" to version field.

- With this release, there are new driver levels across igb, ixgbe, i40e and ice.

- Also, new irdma driver is provided replacing older i40iw driver.


--------------------------------------------------------------------------
6.0 Other Changes
--------------------------------------------------------------------------
  CHANGE:
  
- Include support for new Think System Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter.

- Include support for new ThinkSystem Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter

- Packaging update to support RHEL 8.6 and 8.7.

- Packaged with Lenovo's SLDPK 1.25.

- Replace older RDMA i40iw driver with newer irdma driver.

--------------------------------------------------------------------------
7.0 Limitations
--------------------------------------------------------------------------
  LIMITATION:

Per the OFED_4.17-1-release_notes, RHEL8 OS support for RDMA/IWARP is dependent on
Red Hat's OFED OS release.