Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): Lenovo ThinkSystem SR655 (7Y00, 7Z01) |
Targeted Operating System: SLES15SP4 |
YUM Repository Build Date: 2023_10_11 |
Device: |
ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port OCP Ethernet Adapter (GP servers) | Part Number: 4XC7A08294 Feature Code: na |
||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4002 |
Release History: |
Release Change History Documents |

=========================================================================== Intel v28.0 Network FW Update Release for Linux Release date = 02/16/2023 Package Version: net.e800.da2.ocp-4.22-1.3357.0-4 =========================================================================== CONTENTS ________ 1.0 Change history 2.0 Web information and support phone Number 3.0 Notices and trademarks 4.0 Disclaimer 1.0 Change history ___________________ This FW update package supports Lenovo E810 Aspen Flat DP SFP OCP 3.0 product ONLY. This release includes the following updates: ============================================ Versions: 1) The following E810 images are at NVM 4.22 level. ----------------------------------------------------------------------------------- Device Boot ROM (Option ROM) Firmware (Etrack ID) ----------------------------------------------------------------------------------- ThinkSystem E810-DA2 OCP 1.3357 8001944B 2) NVMUPDATE tool updated to 1.39.32.6 to support new config version. New features: - Support RHEL8.7/9.1, ESXi 8.0 - OROM update support in Recovery mode Description: With this implementation, the NVM host update flow in recovery mode should be the same as in the operational mode. - Defines the IID (Instance IDs) field in the NC-SI packet’s header, which is used to match responses to requests and to differentiate between new and retried commands. Description: According to the spec, If the IID of the current command is the same as the previous command’s IID, the command is a "Retried Command" and the FW shall return the response of previous command (should be done without re-executing the command). When the IID is different than from the previous command, the command is executed. The NC-SI spec is unclear on if the incoming commands IID is compared to the IID of the previous command received on the same channel, package or device. This feature defines a transfer to maintaining a single buffer for the last NC-SI command received on the device per transmitting interface. - Add FC-FEC(CL74) support with optical transceiver 25G-SR - NVMUpdate - only access devices from config file Description: The affected component shall only access devices (read/write flash or registers) listed in config file that match the following criteria: * if device in config file contains: DEVICE and VENDOR all devices with specified device ID and vendor ID will be accessed; * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR all devices with specified 4partID will be accessed, * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR, REVISION all devices with specified 4partID and specific revision will be accessed. Device not listed in config file (do not match the criteria above) shall be marked as "Update not available' in interactive mode. - NVMUpdate - OROM update in recovery Description: If the device is in recovery mode and has the capability of supporting for OROM update in recovery mode. it can be updated OROM either from NVM image or from separate file (FLB). - RoCEv2 LAG - FEC auto-detect for CVL LR/SR mode Description: Only valid FEC modes will be attempted based on the media and PHY type. - Enable hardware arbitration - IPS: 00675913 - FEC Configuration through UEFI HII for 25G CVL adapters Bug fixes: - IPS: 00796141 - E810 fails to link with 10/25Gb SFP28 connect to adapter and 10Gb SFP+ connected Description: Connect Lenovo 10/25Gb SFP28 to E810, Lenovo 10Gb SFP+ to switch (CISCO 9K) Link fails to come up. Fix: Change the preserved "inkDefaultOverridess"ields in the NVM image so that the settings in the NVM images make the firmware to try all the FEC modes during the link training. - IPS: 00736066 - [PA_IO Agile-Sprint202209_BDC_Storage_SR655] E810-DA2 OCP ShareNIC cannot obtain DHCP IP under SR655 Description: BMC failed getting an IP address on the sharenic port of E810-xxvDA2 OCP via DHCP Fix: Use proper packageID SDP settings for SDP0 and SDP1 - IPS: 00735574 - [PA_QUR 22C_BDC_SDV_FW_AMD1P_UEFI][RMK-5883]E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP Destination: E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP. Fix: In implementation, use different variables to identify VSI in different context. - Both ports are loosing link randomly after dcb-map change Destination: The E810 adapter might experience an adapter-wide reset (all ports) when the DCBx willing configuration change (in firmware managed mode) propagated from the switch removes a TC that was RDMA enabled. This typically occurs when removing a TC associated with UP0 because it’s the default UP that RDMA based it’s configuration on. The reset results in a temporary loss in connectivity as the adapter re-initializes. Fix: FW changes along with changes in SW to allow for RDMA to disable QueueSets before suspending the removed TCs from the scheduler tree. Release net.e800.da2.ocp-4.01-1.3282.0-10 includes the following updates: ============================================================================= New features: - Support Windows 11 - Support RHEL8.6/9.0, SLES 15SP4 - Support scalable IOV feature (S-IOV) on the 4th Gen Intel® Xeon® Scalable Processor with the following drivers and OS: o ice 1.9.11 or later o iavf 4.5.3 or later o RHEL 7.9 and 8.5 o SLES 12.5 and 15.3 Note: Please refer to document for more details. Bug fixes: - IPS: 00665409 - [IO_Tatlow_BBFV[UEFI] Intel E810-DA2 PCIE Ethernet Adapter changes do not take effect in network device. Description: During POST, in UEFI setup, set "Active Physical Functions" to "PF0" and save. However, it will still be set to "All" after reboot. Fix: Added a check to ensure only PF0 is used during HII value set. - IPS: 00673260 - E810 OCP adapter fails to link on D-Link switch but E810 PCIe adapter is able to establish link Description: With the same setup, E810 PCIe adapter links up, but E810 OCP adapter can't link up. Fix: Added new section in NVM to match the requirement and bring up link correctly. - IPS: 00688647 - BSOD seen on E810 ICEA driver when using SRIOV/RDMA Description: A customer has SR645 servers in a cluster running Windows 2019 Hyper-V. with SRIOV and RDMA. Randomly the server crashes with a BSOD. Fix: Updated driver to use correct lock and set correct status of queues in passive level thread - IPS: 00711180 - E810-DA2 has no Share NIC feature Description: No Shared option and only Dedicated in the field of Network Interface Port. Fix: Uses correct packageID definition in NVM image. 2.0 Web Sites and Support Phone Number ______________________________________ o You can download new and updated files for Lenovo products from the Lenovo Web site: http://datacentersupport.lenovo.com/ o With the original purchase of an Lenovo hardware product, you have access to extensive support coverage. During the Lenovo hardware product warranty period, you may call the Lenovo HelpCenter for hardware product assistance covered under the terms of the Lenovo hardware warranty. 3.0 Trademarks and Notices __________________________ Lenovo is a registered trademark of Lenovo Corporation in the United States and other countries. Intel is a registered trademark of Intel Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. 4.0 Disclaimer ______________ THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. Lenovo DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, Lenovo GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with Lenovo Corporation.
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2023 Lenovo. All rights reserved |

=============================================================================== Intel Linux device drivers package update =============================================================================== Version [net-28.0-2] =============================================================================== Driver Version ------ ------- ice 1.11.14 i40e 2.22.18 ixgbe 5.18.11 igb 5.13.16 irdma 1.11.58 ice: ---- - Add support for double VLAN in switchdev - Add support for VLAN TPID filters in switchdev - Add support for PPPoE hardware offload - Add i2c write command - Switch: dynamically add VLAN headers to dummy packets - Add EXTTS feature to the feature bitmap - Add mpls+tso support - Expose RSS indirection tables for queue groups via ethtool - Received packets with multicast MAC addresses are now redirected to Flow Director and RSS queues - Allocates transmit/receive queue pairs to be equal to the number of local node CPU threads with the following constraints: o The driver will allocate a minimum of 8 queue pairs, or the total number of CPUs, whichever is lower. o The driver will allocate a maximum of 64 queue pairs. - LAG Active-Backup for RDMA RoCEv2 - Support for VXLAN/GRE in switchdev mode - FEC auto detect in SR/LR aka No-FEC - Support for GTP via switchdev and TC - CRC aka FCS strip control via ethtool - Accelerated Receive Flow Steering (aRFS) might not work correctly, causing traffic to go to unexpected RX queues - Fix DMA mappings leak - Fix ice_xdp_xmit() when XDP TX queue number is not sufficient - config netdev tc before setting queues number - Fix VSI rebuild WARN_ON check for VF - Fix call trace with null VSI during VF reset - Fix tunnel checksum offload with fragmented traffic - Fix crash by keep old cfg when update TCs more than queues - Fix switchdev rules book keeping - ethtool: Prohibit improper channel config for DCB - TC filters do not function correctly when the GTP encryption is enabled in the TC filter add command (enc_key_id 1) - The sense of PFC is lost through a link bounce because the number of TCs is 1. - Adding 16 MAC addresses to an untrusted VF that is attached to a VM, then changing the VF's trust status to on and off again, could cause the added MAC addresses to become non-functional. - Change the number of reserved RX/TX queue pairs per PF i40e: ----- - Added support for the vf-source-pruning private flag - Add VF VLAN pruning - Add support for ethtool -sspeed - ptp: introduce helpers to adjust by scaled parts per million - Add appropriate error message logged for incorrect duplex setting - Fix dropped jumbo frames statistics - Fix VF's MAC Address change on VM - Fix to stop tx_timeout recovery if GLOBR fails - Fix incorrect address type for IPv6 flow rules - Fix ADQ rate limiting for PF - Fix VF set max MTU size - Fix set max_tx_rate when it is lower than 1 Mbps - Fix DMA mappings leak - Fix ethtool rx-flow-hash setting for X722 - Fix VF hang when reset is triggered on another VF - Fix no connection when disable vlan strip before adding vlan - Fix memory leak when driver_register() fails - Fix delete if NULL check before dev_kfree_skb - Fix convert to new udp_tunnel infrastructure - Fix reading WoL settings from the adapter - Fix disallow ip4 and ip6 l4_4_bytes - Fix fd rule(src-ip) creation for flow type ip6 - Fix error message for hw limitation for TC VSI irdma: ------ - Previous to this release, the ToS-to-user priority mappings were hard-coded in Linux to use only 0, 2, 4, 6 VLAN PFC priority values with RDMA traffic. Now in order to use other priorities with RDMA traffic (that is, 1, 3, 5, 7), a VLAN is required to be setup using the egress-qos-map option. For example, to map all priority 0 as priority 3, one can use: ip link add link name type vlan id egress-qos-map 0:3 1:0 - An rping can fail after a system reboot. Version [net-27.6-4] =============================================================================== Driver Version ------ ------- ice 1.9.11 i40e 2.20.12 ixgbe 5.16.5 igb 5.11.4 irdma 1.9.30 ice: ---- - ADQ support for 256 queues pairs - ADQ acceleration using independent pollers - ADQ auto configuration script - ADQ per-tc inline Flow Director - Support for Selectable Scheduler Topology - Support for tc forward to queue - Initial support for S-IOV - Due to the previous bugs in PF-to-port mapping in both NVM and UEFI Driver, old NVMs are not compatible with the new UEFI driver. As it pertains to HII, NVMs can still be updated via FMP. - When a VF interface is set as 'up' and assigned to a namespace, and the namespace is then deleted, the dmesg log may show the error Failed to set LAN Tx queue context, error: ICE_ERR_PARAM followed by error codes from the ice and iavf drivers. - Repeatedly assigning a VF interface to a network namespace then deleting that namespace might result in an unexpected error message and might possibly result in a call trace on the host system. - When the queue settings of a port are modified using the ethtool -L ethx combined XX command, the Interrupt Moderation settings reset to default. - When the maximum allowed number of VLAN filters are created on a trusted VF, and the VF is then set to untrusted and the VM is rebooted, the iavf driver may not load correctly in the VM and may show errors in the VM dmesg log. - If trusted mode is enabled for a VF while promiscuous mode is disabled and multicast promiscuous mode is enabled, unicast packets may be visible on the VF and multicast packets may not be visible on the VF. Alternatively, if promiscuous mode is enabled and multicast promiscuous mode is disabled, then both unicast and multicast packets may not be visible on the VF interface. - A VF may incorrectly receive additional packets when trusted mode is disabled but promiscuous mode is enabled. - Receive hashing might not be enabled by default on Virtual Functions when using an older iavf driver in combination with a newer PF driver version. - Linux sysctl commands, or any automated scripting that alerts or sets /proc/sys/ attributes using sysctl, might encounter a system crash that includes irdma_net_event in the dmesg stack trace. Workaround: With OOT irdma-1.8.X installed on the system, avoid running sysctl while drivers are being loaded or unloaded. - irdma stops working if the number of ice driver queues are changed (ethtool -L) while the irdma driver is loaded. As a workaround, remove (if previously loaded) and reload irdma after changing the number of queues. i40e: ----- - Add support for ethtool -s speed - VLAN tagged traffic sent from other VFs attached to NIC can be seen on other VFs. This is due to issue with NIC settings and offload settings of VFs. As a workaround, disable TX VLAN offload on VFs: ethtool -K tx-vlan-offload off This does not affect egress traffic from outside of the NIC igb: ---- - Fix dropped PTP timestamps on i210 Version [net-27.3.0] =============================================================================== Driver Version ------ ------- ice 1.8.8 i40e 2.19.3 ixgbe 5.14.6 igb 5.9.3 irdma 1.8.46
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2023 Lenovo. All rights reserved |