Lenovo YUM Repository
Release and Change History








Bundle Release Information:
Targeted Server Family (Machine Type): ThinkSystem SR650 V2 (7Z72, 7Z73)
Targeted Operating System: SLES15SP5
YUM Repository Build Date: 2024_05_10

YUM Repository Release Version: SIAgile23-1

Device:
ThinkSystem Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter Part Number: 4XC7A08278
Feature Code: na
PCIe Sub Vendor ID: 0x8086
PCIe Sub Device ID: 0x000F


Release History:

Release Change History Documents

Intel Networking Adapter/Device Linux Firmware




===========================================================================
Intel v28.2 Network FW Update Release for Linux
Release date = 08/01/2023
Package Version: net-9.30-6.20-1.3450.0-10
===========================================================================


CONTENTS
________

1.0  Change history
2.0  Web information and support phone Number
3.0  Notices and trademarks
4.0  Disclaimer


1.0  Change history
___________________


This release includes the following updates:
============================================

Versions:

1) The following X710/XXV710 images are at NVM 9.30 level.
------------------------------------------------------------------------------------------------
                  Device                         Boot ROM (Option ROM)  Firmware (Etrack ID)
------------------------------------------------------------------------------------------------
    System X and ThinkSystem X710-DA2            1.3450.0               8000EE1C
    ThinkSystem X710-T4                          1.3450.0               8000EE1D
    ThinkSystem X710-DA4                         1.3450.0               8000EE1B
    ThinkSystem XXV710-DA2                       1.3450.0               8000EE21
    ThinkSystem X710-T2L OCP                     1.3450.0               8000EE20
    ThinkSystem X710-T2L PCIe                    1.3450.0               8000EE1A
    ThinkSystem X710-T4L PCIe                    1.3450.0               8000EE1F
    ThinkSystem X710-T4L OCP                     1.3450.0               8000EE19
    ThinkSystem X710-T2L Internal Lock OCP       1.3450.0               8000EE1E

The following X722 images are at NVM 6.20 level.
------------------------------------------------------------------------------------------------
                  Device                         Boot ROM (Option ROM)  Firmware (Etrack ID)
------------------------------------------------------------------------------------------------
    ThinkSystem SR530/SR550/SR570/SR590 X722 LOM 1.3450.0               80003FE0
    ThinkSystem ST550 X722 LOM                   1.3450.0               80003FD0
    ThinkSystem SR630/SR650/SR850/SR950 X722 LOM 1.3450.0               80003FCF
    ThinkSystem SN550/SN850 X722 LOM             1.3450.0               80003FD5
    ThinkSystem SD650 X722 LOM                   1.3450.0               80003FE1
    ThinkSystem SE350 X722 LOM                   1.3450.0               80003FD1
    ThinkAgile SR530/SR550 X722 LOM              1.3450.0               80003FE0
    ThinkAgile ST550 X722 LOM                    1.3450.0               80003FD0
    ThinkAgile HX and VX Rack servers X722 LOM   1.3450.0               80003FCF
    ThinkAgile SN550/SN850 X722 LOM              1.3450.0               80003FD5
    ThinkAgile DS650 X722 LOM                    1.3450.0               80003FE1

The following X710 images are at NVM 9.20 level.
------------------------------------------------------------------------------------------------
                  Device                         Boot ROM (Option ROM)  Firmware (Etrack ID)
------------------------------------------------------------------------------------------------
    X710-DA2 ML2                                 1.3357.0               8000DEE5

The following X550 images are at NVM 3.60 level.
------------------------------------------------------------------------------------------------
                  Device                         Boot ROM (Option ROM)  Firmware (Etrack ID)
------------------------------------------------------------------------------------------------
    Intel X550-T1                                1.3141.0               80001745
    Intel X550-T2                                1.3141.0               80001746

The following adapters are ONLY for Option ROM
------------------------------------------------------------------------------------------------
                  Device                         Boot ROM (Option ROM)  Firmware (Etrack ID)
------------------------------------------------------------------------------------------------
    I340/I350                                    1.3450.0               NA
    X520/X540                                    1.3141.0               NA
    I210                                         1.3450.0               NA

2) NVMUPDATE tool updated to 1.39.56.8 to support new config version.

This update supports Lenovo System X, ThinkServer, ThinkSystem, and ThinkAgile products, except DS530.

Important Note:  If you choose to install the nvmupdate64e utility manually, please ensure that you install
version 1.39.56.8 or newer.

Earlier versions of nvmupdate64e tool may not be not compatible or include all latest supported features.

New OS Support:
  - Support RHEL8.8/9.2, SLES 15.5

FVL/SGVL
--------
New features:
  - Get Link Status AQC response when SFP module is not initialized.

    Description:
    If the Get Link Status AQC is sent when the SFP module is not
    initialized yet, the link can be lost.

    When the SFP module is not initialized yet, FW will try again in a
    reasonable timeout.

Bug fixes:
  - IPS: 00819239 - [Kahauale_BBFV_HCT]X710-T4L NIC adapter can't saved the
    "Active Physical Functions" option on uEFI menu.
    IPS: 00831264/00844425 - XXV710-DA2 PCIe Adapter NIC port didn't
    disable after changed the "Active physical functions"

    Description:
    Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Adapter NIC port didn't disable
    after changed the "Active Physical" setting on uEFI menu.

    Fix:
    Disable the "device level" options in the firmware during image
    downgrade to a version earlier than FVL9.3

  - IPS: 00840914 - [PA_IO Agile-Sprint202310_BDC_Storage_flex]SRIOV
    enable/disable both can do SRIOV features

    Description:
    OS can still create SRIOV VFs when the adapter HII already disables SRIOV
    in the BIOS

    IPS: 00841528 - [PA_IO Agile-Sprint202310_BDC_Storage_SD530] Intel X722
    LOM test SR-IOV function cannot enable VF under ESXi8.0u2 OS

    Description:
    Open to enter ESXi Host Client-Manage-Hardware-PCI Devices-Select Port
    "Intel X722 10GB SFP+" Configure SR-IOV 2.UEFI has set SR-IOV function
    3.ESXi8.0u2 Unable to enable VF redhat 9.2 can work well.

    Fix:
    Correctly set SR-IOV Control Capable bit for Lenovo images,

  - IPS: 00839473 - [PA_IO Agile-Sprint202209_BDC_oceancat_Sprint202310]X722
    lom WOL fail in SD650.

    Description:
    WOL function UEIF page show gray, OS can not enable WOL function

    Fix:
    Enable force link down requests and map channel number in a descending
    order. Enable AltRAM implementation then reset corrupted memory block and
    recalculate MSI_X VF vectors.

  - IPS: 00831248 - XXV710 VPD info question

    Description:
    lspci -s BUS:Device.Function -vvv command to check VPD info, but it
    can't show out the VPD info

    Fix:
    Enable VPD bit in NVM image

  - IPS: 00769725 - [Hakuba] Abnormal cable plug (unplug) event on port 2
    and 3 with Intel X710-T4L

    Description:
    Port2 and port3 of X710-T4L PCIE cannot display event in audit log and
    link status/speed in inventory when plug/unplug the cable.

    Fix:
    There are missing MCTP link status changes as mixed PF no. with port
    no. in the MCTP Link Status change handler, and overflowing PLDM queue
    with RDE events that were classified as Big Event.

    Map Port No. to the corresponding PF and continue, add additional
    condition to disable unplanned eventReceiver physical address change.
    Disable RDE events in the presence of asynchronous MCTP implementation
    without polling for Big Events

    Note: it may still occur in loopback mode.

  - IPS: 00725539 - Link down on x722 4x10Gb SFP+ PHY card with 27.3 code
    level (800039xx)

    Description:
    After upgrading the FW, all ports are down.

    Fix:
    Force OCP PnP Autodetection flow after NVM update.

  - Resolved an issue where a rare PCI speed degradation with Gen3 to Gen2
    was seen during extensive link tests after a reset is caused by a core
    reset on an ICX-D platform.

  - Resolved an issue where during a write, with http PATCH method
    triggered, the LLDP Disable Valid bit was ignored, which resulted in a
    skip of write in all scenarios instead of just for the same LLLDP
    Enabled value.

  - Resolved an issue where if BMC bonding was disabled, NCSI mode was set
    to a Manual Switch Mode (depending on the platform), and BMC share port
    has changed before doing a power cycle, recovery mode would occur.
    Other prerequisites include disabled WOL, disabled LLDP, enabled PXE no
    drop, and disabled auto power-on after power loss (in BIOS).

  - Fixed an issue where the processing port id was always the same as the
    mac address

  - Previously, the addition of PCIe re-timers added to the total channel
    latency causing replay timer timeout correctable errors.

  - Resolved an issue where PLDM type MCTP packets were not accepted due to
    missing configuration for PCIe VDM


I350/340/210
------------
New features:
  - IPS: 00699338 - Name of I350 interlock in XCC is inconsistent with V1

    Description:
    Card Name field shall be taken from V1 VPD field instead of "large
    resource string". This change applies to 1G Lenovo devices with enabled
    AIM support and existing V1 VPD field.


Release net-9.2-6.2-1.3357.0-2 includes the following updates:
==============================================================
New features:
  - Defines the IID (Instance IDs) field in the NC-SI packet's header,
    which is used to match responses to requests and to differentiate
    between new and retried commands.

    Description:
    According to the spec, If the IID of the current command is the same as
    the previous command's IID, the command is a "Retried Command" and the
    FW shall return the response of previous command (should be done
    without re-executing the command). When the IID is different than from
    the previous command, the command is executed.

    The NC-SI spec is unclear on if the incoming commands IID is compared
    to the IID of the previous command received on the same channel,
    package or device. This feature defines a transfer to maintaining a
    single buffer for the last NC-SI command received on the device per
    transmitting interface.


Bug fixes:
  - XXV710DA2 adapter intermittently lose link when doing DC power cycle test

    Description:
    XXV710DA2 adapter intermittently lose link when doing DC power cycle
    test, this can be reproduced in about 200 DC cycle.

    Fix:
    When the FW starts to run, the gearbox has to be initialized and
    configuration needs to be downloaded from the NVM and applied. If one
    of the operation fails the FW will try again (several times). In this
    case the configuration failed with the error which was not covered.
    Error handling extended in the code to cover all cases

  - Package Port Control command with Port Control equals 0x1 works like
    reset if link is already up

    Description:
    In Campbell Pond, send Package Port Control Command to disable the
    port, send command to enable it, then send command to enable it again.
    The port is down instead of up.

    Fix:
    Added link status check in package command.

  - Link Status Change AEN event is not send after link down

    Description:
    Sending AEN Enable command with Link Status Change equals true, then
    sending Port Control Command with Port Control field equals 0x0 -
    disable. There is no event after link down.

    Fix:
    Changed event rejection condition to response.

  - After running reboot 123 times with qtest, slot4 (X710-T2L) shows an error

    Description:
    Used qtest ro run reboot 123 times, xcc web appears: PCIe Correctable
    Error Threshold limit has been exceeded at Segment 0x0000 Bus 0xA8
    Device 0x00 Function 0x01.

    Fix:
    Adjust the replay timer timeout value for different scenarios.


Release net-9.0-6.0-1.3266.0-6 includes the following updates:
==============================================================
New features:
  - Support RHEL8.6/9.0, SLES 15SP4


Bug fixes:
  - IPS: 00685894 - I210 Option Rom Request

    Description:
    Lenovo required support for specific 4-part ID, additional HII fields
    in "NIC Configuration" menu for I210 AT, remove "Device Level
    Configuration" and "iSCSI Configuration" fields

    Fix:
    Added and removed corresponding fields.

  - IPS: 00729600 - XXV710 Link issues

    Description:
    While DC power cycle, the port maybe lose the link

    Fix:
    When the FW starts to run, retry to configure the Retimer in case of
    error.


1) With the X710-T2L OCP 3.0 adapter, note that:

a. If you install and run this adapter in Lenovo's AMD-based SR635 or SR655 system, in RHEL7 or RHEL8 OS.
b. And if you plan to run Intel BOOTUTIL tool in the OS with Intel iqvlinux driver.
c. Then first, during system boot, you need to go into System BIOS and set IOMMU to disabled. Or restart the system and
   go to System BIOS and set IOMMU to disabled.
d. Then Intel BOOTUTIL in Linux, with iqvlinux, should be functional and you can read OROM content for both ports.
e. If you have IOMMU enabled in the System BIOS, then you can only read the OROM content for the second port and first
   port. The firt port would be displayed for Flash Firmware as "Flash Unknown".

NOTE that this is ONLY with AMD-based SR635/SR655 systems, and also ONLY with RHEL7 and RHEL8.

2) With v27.1 release, add support for new SKUs:

  - ThinkSystem Intel X710-T2L 10GBASE-T 2-Port PCIe Ethernet Adapter
  - ThinkSystem Intel X710-T4L 10GBASE-T 4-Port PCIe Ethernet Adapter
  - ThinkSystem Intel X710-T4L 10GBASE-T 4-Port OCP Ethernet Adapter
  - ThinkSystem Intel X710-T2L 10GBASE-T 2-port Internal Lock OCP Ethernet Adapter
  - ThinkSystem Intel I350 1GbE RJ45 4-port Internal Lock OCP Ethernet Adapter

3) With v27.3 release:
- FW/NVM updates for X722, X710, XXV710 and X550 based products.

  Add support for new SKUs:
  - Intel(R) Ethernet I210-T1 LOM

Note on Firmware Recovery Mode:

When a device is in Firmware Recovery mode it will not pass traffic or allow any configuration; you can only
attempt to recover the device's firmware. A device will enter Firmware Recovery mode if it detects a problem
that requires the firmware to be reprogrammed.

Resolving Firmware Recovery Mode Issues:

If your device is in Firmware Recovery mode you can restore it to factory defaults using the latest NVM
Update Package. Download the latest NVM Update Package from your vendor's support website and follow
the instructions in it.

*** NOTES:

- Before initiating device recovery, the integrity of the host operating system, device drivers
and firmware utilities must be verified and reinstalled if necessary. Fully functional operating
system, device drivers and tools are required for device recovery.

- AC power cycle your system even if the instructions do not indicate that an AC power cycle is required.
A power cycle is required to enable the device to restore and reload critical device settings to enable recovery.
To perform an AC power cycle, do the following:

a. Shut down the system if it is powered up.
b. Unplug all AC power cords from the system.
c. Leave the AC power cords unplugged for 15 seconds to allow the system power supply to discharge completely.
d. Plug in AC power cords to the system.

- Firmware Recovery Mode Errors and Messages:

When a device is in Firmware Recovery mode, the device drivers and preboot software and utilities may log or
display messages such as the following:

a. Firmware recovery mode detected. Limiting functionality.
Refer to the Intel(R) Ethernet Adapters and Devices User Guide for details on firmware recovery mode.
b. Firmware recovery mode detected. Initialization failed.
c. Firmware recovery mode detected. Limiting functionality.
d. PXE-E0C: Firmware recovery mode detected. Initialization failed.


2.0 Web Sites and Support Phone Number
______________________________________

   o  You can download new and updated files for Lenovo products from the Lenovo
     Web site:

     http://datacentersupport.lenovo.com/

  o  With the original purchase of an Lenovo hardware product, you have access to
     extensive support coverage.  During the Lenovo hardware product warranty
     period, you may call the Lenovo HelpCenter for hardware product assistance
     covered under the terms of the Lenovo hardware warranty.


3.0 Trademarks and Notices
__________________________

  Lenovo is a registered trademark of Lenovo Corporation in the United States
  and other countries.

  Intel is a registered trademark of Intel Corporation in the United States
  and other countries.

  Linux is a registered trademark of Linus Torvalds in the United States and
  other countries.

  Other company, product, and service names may be trademarks or service marks
  of others.


4.0 Disclaimer
______________

  THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.
  Lenovo DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED,
  INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS
  FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE
  INFORMATION IN THIS DOCUMENT.  BY FURNISHING THIS DOCUMENT, Lenovo
  GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS.

  Note to U.S. Government Users -- Documentation related to
  restricted rights -- Use, duplication or disclosure is subject
  to restrictions set forth in GSA ADP Schedule Contract with
  Lenovo Corporation.






Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2024 Lenovo. All rights reserved

Intel Networking Adapter/Device SLES 15 Driver



===============================================================================
Intel Linux device drivers package update
===============================================================================

Version [net-28.2-0]
===============================================================================
Driver     Version
------     -------
ice        1.12.7
i40e       2.23.17
ixgbe      5.19.6
igb        5.14.16
irdma      1.12.55


New OS Support:
    - SLES 15.5

ice:
----
    - Large VF support (up tp 256 Qs)
    - User can reassign PF LUT for VF usage
    - Devlink port split support
    - Tx rate limit support
    - Dynamic msi-x vector allocations to various device functions via
      devlink API

    - PTP fixes for Timestamp timeout error.
    - Resolved an issue where when using certain DDP package versions,
      802.1ad type VLANs might not be correctly enabled on SIOV or SR-IOV
      interfaces.
    - Resolved an issue where running traffic via Open vSwitch (when an
      SR-IOV VF have specific ipv6 address assigned), works for 20min
      (until the neighbor table is clean on the switch/router) then it
      stops until IPv6 from VF is deleted.
    - Previously, the Switchdev feature's VF to VF communication was not
      functional in the ice driver versions 1.10.1.2, 1.10.1.2.2, and
      1.11.14.
    - Resolved an issue where the NVM update process would need Power On
      Reset on PTP devices unless the user manually turned off PTP activity
      before the NVM update process was started.
    - Resolved an issue where a performance issue caused the GNSS write
      commands to be delayed and not delivered until the next commands
      appeared.
    - Resolved an issue where modifying inner or outer VLAN offload caps
      while the link is down might break communications when the link is
      later brought back up.
    - Resolved an issue for Linux ice driver v1.7.16+ on E810 four-port
      SKUs where VF could not be created on certain high-core count
      platform because PF had exhausted all the MSIX interrupts.
    - Resolved an issue where repeatedly adding/deleting a VF from a
      namespace while also repeatedly changing its trust mode status could
      result in call trace after a significant number of iterations.
    - Previously an issue existed in the IAVF driver where the VF couldn't
      communicate on inner or outer VLANs if the number of rx queues was
      modified after switching off VLAN offloads.
    - Resolved an issue when spoofchk was turned on, the VF device driver
      would have pending DMA allocations while it was released from the
      device.
    - Previously a UEFI PXE installation of Red Hat Enterprise Linux 8.4 on
      a local disk resulted with the system failing to boot.
    - Resolved an issue where auxiliary module conflicts would be reported
      between i40e and ice during the generation and installation of Linux
      rpm packages.
    - Resolved an issue where "ethtool -L/G" made E810 link down.

i40e:
-----
    - Add PHY debug register dump
    - Add mdd-auto-reset-vf private flag

    - Fix FW v8.15 double vlan issue
    - Fix 32bit FW gtime wrapping issue for nvmupdate
    - Fix err -110 after DCB ETS configuration
    - Fix pointer dereference after free
    - Fix i40e_setup_misc_vector() error handling
    - Fix missing rtnl locking when setting up pf switch
    - Fix accessing vsi->active_filters without holding lock
    - Fix SW DCB configuration when ADQ is set
    - Fix PTP pins verification
    - Fix passing tainted expression to kzalloc()
    - Fix error by one for traffic class number
    - Fix compilation issue with gcc older than 5.0.0

irdma:
------
    - Support CVL 4.30, FVL 9.30
    - Add readable descriptions to the printed AE codes in irdma to help
      with debug and provide a better insight on what is going on.

    - Fix the fixed value for ret code, make a vchnl re-negotiation

ixgbe:
------
    - Add xdp frags support to ndo_xdp_xmit

    - Fix kernel compilation issue related to u64_stats_fetch_ begin/retry

igb:
----
    - Fix bitmaps declarations
    - Fix array size overrun
    - Fix adjfreq compatibility
    - Fix e1000_read_nvm() error handling
    - Fix always true if condition
    - Fix netif_napi_add compilation for igb
    - Fix warnings about ignored return value

Version [net-28.0-2]
===============================================================================
Driver     Version
------     -------
ice        1.11.14
i40e       2.22.18
ixgbe      5.18.11
igb        5.13.16
irdma      1.11.58

ice:
----
    - Add support for double VLAN in switchdev
    - Add support for VLAN TPID filters in switchdev
    - Add support for PPPoE hardware offload
    - Add i2c write command
    - Switch: dynamically add VLAN headers to dummy packets
    - Add EXTTS feature to the feature bitmap
    - Add mpls+tso support
    - Expose RSS indirection tables for queue groups via ethtool
    - Received packets with multicast MAC addresses are now redirected to
      Flow Director and RSS queues
    - Allocates transmit/receive queue pairs to be equal to the number of
      local node CPU threads with the following constraints:
      o The driver will allocate a minimum of 8 queue pairs, or the total
        number of CPUs, whichever is lower.
      o The driver will allocate a maximum of 64 queue pairs.
    - LAG Active-Backup for RDMA RoCEv2
    - Support for VXLAN/GRE in switchdev mode
    - FEC auto detect in SR/LR aka No-FEC
    - Support for GTP via switchdev and TC
    - CRC aka FCS strip control via ethtool

    - Accelerated Receive Flow Steering (aRFS) might not work correctly,
      causing traffic to go to unexpected RX queues
    - Fix DMA mappings leak
    - Fix ice_xdp_xmit() when XDP TX queue number is not sufficient
    - config netdev tc before setting queues number
    - Fix VSI rebuild WARN_ON check for VF
    - Fix call trace with null VSI during VF reset
    - Fix tunnel checksum offload with fragmented traffic
    - Fix crash by keep old cfg when update TCs more than queues
    - Fix switchdev rules book keeping
    - ethtool: Prohibit improper channel config for DCB
    - TC filters do not function correctly when the GTP encryption is
      enabled in the TC filter add command (enc_key_id 1)
    - The sense of PFC is lost through a link bounce because the number of TCs is 1.
    - Adding 16 MAC addresses to an untrusted VF that is attached to a VM,
      then changing the VF's trust status to on and off again, could cause
      the added MAC addresses to become non-functional.
    - Change the number of reserved RX/TX queue pairs per PF


i40e:
-----
    - Added support for the vf-source-pruning private flag
    - Add VF VLAN pruning
    - Add support for ethtool -s  speed 
    - ptp: introduce helpers to adjust by scaled parts per million
    - Add appropriate error message logged for incorrect duplex setting

    - Fix dropped jumbo frames statistics
    - Fix VF's MAC Address change on VM
    - Fix to stop tx_timeout recovery if GLOBR fails
    - Fix incorrect address type for IPv6 flow rules
    - Fix ADQ rate limiting for PF
    - Fix VF set max MTU size
    - Fix set max_tx_rate when it is lower than 1 Mbps
    - Fix DMA mappings leak
    - Fix ethtool rx-flow-hash setting for X722
    - Fix VF hang when reset is triggered on another VF
    - Fix no connection when disable vlan strip before adding vlan
    - Fix memory leak when driver_register() fails
    - Fix delete if NULL check before dev_kfree_skb
    - Fix convert to new udp_tunnel infrastructure
    - Fix reading WoL settings from the adapter
    - Fix disallow ip4 and ip6 l4_4_bytes
    - Fix fd rule(src-ip) creation for flow type ip6
    - Fix error message for hw limitation for TC VSI

irdma:
------
    - Previous to this release, the ToS-to-user priority mappings were
      hard-coded in Linux to use only 0, 2, 4, 6 VLAN PFC priority values
      with RDMA traffic. Now in order to use other priorities with RDMA
      traffic (that is, 1, 3, 5, 7), a VLAN is required to be setup using
      the egress-qos-map option. For example, to map all priority 0 as
      priority 3, one can use: ip link add link  name 
      type vlan id  egress-qos-map 0:3 1:0
    - An rping can fail after a system reboot.


Version [net-27.6-4]
===============================================================================
Driver     Version
------     -------
ice        1.9.11
i40e       2.20.12
ixgbe      5.16.5
igb        5.11.4
irdma      1.9.30

ice:
----
    - ADQ support for 256 queues pairs
    - ADQ acceleration using independent pollers
    - ADQ auto configuration script
    - ADQ per-tc inline Flow Director
    - Support for Selectable Scheduler Topology
    - Support for tc forward to queue
    - Initial support for S-IOV

    - Due to the previous bugs in PF-to-port mapping in both NVM and UEFI
      Driver, old NVMs are not compatible with the new UEFI driver. As it
      pertains to HII, NVMs can still be updated via FMP.
    - When a VF interface is set as 'up' and assigned to a namespace, and the
      namespace is then deleted, the dmesg log may show the error Failed to set
      LAN Tx queue context, error: ICE_ERR_PARAM followed by error codes from
      the ice and iavf drivers.
    - Repeatedly assigning a VF interface to a network namespace then deleting
      that namespace might result in an unexpected error message and might
      possibly result in a call trace on the host system.
    - When the queue settings of a port are modified using the ethtool -L ethx
      combined XX command, the Interrupt Moderation settings reset to default.
    - When the maximum allowed number of VLAN filters are created on a trusted
      VF, and the VF is then set to untrusted and the VM is rebooted, the iavf
      driver may not load correctly in the VM and may show errors in the VM
      dmesg log.
    - If trusted mode is enabled for a VF while promiscuous mode is disabled
      and multicast promiscuous mode is enabled, unicast packets may be visible
      on the VF and multicast packets may not be visible on the VF.
      Alternatively, if promiscuous mode is enabled and multicast promiscuous
      mode is disabled, then both unicast and multicast packets may not be
      visible on the VF interface.
    - A VF may incorrectly receive additional packets when trusted mode is
      disabled but promiscuous mode is enabled.
    - Receive hashing might not be enabled by default on Virtual Functions when
      using an older iavf driver in combination with a newer PF driver version.
    - Linux sysctl commands, or any automated scripting that alerts or sets
      /proc/sys/ attributes using sysctl, might encounter a system crash that
      includes irdma_net_event in the dmesg stack trace.
      Workaround: With OOT irdma-1.8.X installed on the system, avoid running
      sysctl while drivers are being loaded or unloaded.
    - irdma stops working if the number of ice driver queues are changed
      (ethtool -L) while the irdma driver is loaded. As a workaround, remove
      (if previously loaded) and reload irdma after changing the number of
      queues.

i40e:
-----
    - Add support for ethtool -s  speed 

    - VLAN tagged traffic sent from other VFs attached to NIC can be seen on
      other VFs. This is due to issue with NIC settings and offload settings of
      VFs. As a workaround, disable TX VLAN offload on VFs:
          ethtool -K  tx-vlan-offload off
      This does not affect egress traffic from outside of the NIC

igb:
----
    - Fix dropped PTP timestamps on i210


Version [net-27.3.0]
===============================================================================
Driver     Version
------     -------
ice        1.8.8
i40e       2.19.3
ixgbe      5.14.6
igb        5.9.3
irdma      1.8.46





Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2024 Lenovo. All rights reserved