Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): ThinkSystem SR650 V3 (7D75, 7D76, 7D77) |
Targeted Operating System: RHEL9.2 |
YUM Repository Build Date: 2024_05_10 |
Device: |
ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter | Part Number: 4Y37A78835 Feature Code: na |
||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0506 |
Release History: |
Release Change History Documents |
BIOS and Firmware Update for ThinkSystem RAID 540-x Adapters Supported Adapters: ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) NOTE TO SERVICE - Reference RETAIN #N/A Version 52.27.0-5216 - Moderate Impact/Low Probability of Occurrence ------------------- BIOS:7.27.00.0 UEFI Driver:0x071B0200 HII: 07.27.04.01 IMR FW: 5.270.01-3950 package 52.27.0-5216 MR 7.27 Defects: Possible division or modulo by zero in enclosure management code.(DCSG01224310 HBA discovery failed with Phase 24 Storelib and StorelibTest(DCSG01207008 7.23 PA1: Data abort very early Start of Day(DCSG01225578 PEX89000: Fix function parenthesis in packet generator functions(DCSG01247963 MegaRAID 7.23: Firmware continuously logging "PESTATUS_DEVHANDLE_OUT_OF_RANGE" during crash dump(DCSG01288261 Skip Enclosure Power Cycle test for OEM BST as it is not relevant and results in failure(DCSG01303587 Firmware reports dual ports for SATA drives.(DCSG01352291 Fix Kill Adapter when powering off one of the attached enclosures(DCSG01217941 Fix for the MPB test(DCSG01209348 System restarts by itself and PL Fault 00005854 LinkRegister 01475093(DCSG01304319 Hardware Workaround:Link between Controller and expander not always recovering after link reset(DCSG01196230 Locate LED operation does not work for NVMe drive slot on UBM backplane(DCSG01230479 Same slot number is assigned to x1 link width drives connected to consecutive controller PHYs when an I2C backplane detection fails(DCSG01375808 Firmware is not incrementing the DFC Change Count value when there is a DFC change detected by the firmware.(DCSG01287092 SPILIB2: AutoStore command causes NVSRAM to ignore write enable comand(DCSG01218898 Secure Boot: Key mismatch error after FW image with 3K SHA3 256 w/0 ASN1 Header(DCSG00987745 MR_7.24: firmware fault on 9560 megaraid card upon malformed sense command(DCSG01331157 Too much text returned for TTY Read(DCSG01373054 [Aero/Ventura] Add check for Sense Data size(DCSG01178348 Build all failed on firmware tip code(DCSG01381053 LBA information missing from sense data with Medium Error Sense Key for SATA drives.(DCSG01183332 Export security does not work(DCSG01350835 Series 96xx: RMC SPI1 interrupt may assert when workaround is removed(DCSG01254315 Certain DS spin up sense codes are not filtered even with filtering enabled(DCSG01253216 MR7.24 Excessive prints while IO's are running(DCSG01339937 Enable encryption command enables security on multiple drives(DCSG01346635 While setting WCE(Disk Write Cache)=0 for JBOD; Firmware throws error mode_sense_10 buffer requested 400 but available 4, command failed.(DCSG01365204 MegaRaid7.23: firmware hit assertion failure memory.h at line 447: isInAddressibleRange(physAddrLow)(DCSG01310030 Fix inconsistent delimiter in Megamon command(DCSG01328543 Use correct flags in mbedTLS build for PEX89000(DCSG01317350 Uninitialized scalar variable access in UBM Backplane management and I2C driver code.(DCSG01339421 PCI slot and host serial number is set to default values.(DCSG01188813 Controller hit Fatal error with exception when run PR and CC at same time(DCSG01267776 NVMe Encapsulated MPI command not failed when it is blocked by IO Unit Page 13.(DCSG01294635 Continuation of defect 1304319 around unexpected system restart. Use this to further polish/harden the solution.(DCSG01328744 Update M.2 boot PSOC v1.17 caused Firmware hit ERROR: Exception Handler Called(DCSG01239775 IT controller firmware sending MCTP version numbers in reverse order(DCSG01234654 Aero: Incorrect topology phys memory allocation(DCSG01185588 Reading IO Unit Page 13 returns junk data(DCSG01292339 Fix controller info on NVMe Clock mode support when in SAS SATA only profile(DCSG01321714 LSA 7.23: Rebuild background operation progress bar disappears only after manual refresh.(DCSG01262337 C0:[141]:[Error] Signing Buffer Failed Sts:2 mesg after import successfully the certificate and reboot(DCSG01270486 Enable the TTY Replace setting in NVDATA(DCSG01333745 Self test aborts when Open Zone command issued on a Security locked drive(DCSG01194141 Fix too much OOB debug prints in the firmware log in iMR(DCSG01232395 Fix print statements in some debug firmware(DCSG01324759 Storcli hangs with no output after running script cleaning up debug variables.(DCSG01341519 Io Unit Control with Remove device fails if MPI function blocking is enabled. IO Unit Page 13 is writeable.(DCSG01270812 Phase 24 Code analysis tool Defects related to SPDM(DCSG01224346 [SATA] SATA Initialization fails on certain large capacity SATA drives(DCSG01194600 Fix underflow in print firmware(DCSG01353729 Update copyright information in the header file.(DCSG01266013 QErr value in Control mode page for NCQ SATA devices is set to 0 instead of 1.(DCSG01375632 Fix the size expression in a profile debug function(DCSG01272481 Fix Inconsistency in delimiter usage in mfc print(DCSG01328526 7.23 Alpha: BGOps appear to not be monitored properly(DCSG01285341 Build all failed on firmware tip code(DCSG01343959 Foreign Config import Error message not proper in HII(DCSG01089538 Rebuild did not start on dedicated hotspare when one member drive was failed(DCSG01320150 [SATA Only] NCQ Errors observed with running Read/Write IOs along with SCSI Unmap to SATA drive(DCSG01254091 MegaRAID 7.23: Running get snapdump and delete snapdump simultaneously (get snapdump first, immediately followed by delete) causes a get failure(DCSG01248884 Flash / upgrade from Release Order Package 4567 to Release Order Package 4601 failed on JBOD mode Ctrl (profile = 20)(DCSG01312941 Firmware was not repairing an NVMe drive with detached Inactive Namespace.(DCSG01321255 SAS drive keeps failing SCSI TUR with Check condition due to Controller not sending Periodic Notify (Enable Spinup)(DCSG01232852 Preboot Trace Buffer (PTB) disable operation fails in preboot application HII(DCSG01186641 BST Failure: Buffer Overflow Assertion During TTY Retrieval(DCSG01233951 Found PR not paused when scheduled consistency check starts(DCSG01292937 Disable SATA protocol when in optical mode(DCSG01194126 PSOC details are displayed with discrete logic iMR controller(DCSG01359864 9500 Series- host with eight PHY controller hangs during warm reboot(DCSG01289054 Secured configured drives changing to unconfigured after reboot(DCSG01249672 SPILIB2: Series 9700 Chip Select Timing registers default to zero(DCSG01182027 Drive stays in UBAD state when doing running drive insertion/removal test(DCSG01349665 BST Failure: Exception During 95xx Cache Offload BST(DCSG01236056 Fix wrong drive temperature information on SATA drive models that do not support temperature reading(DCSG01265562 Cache offload power and time values updates for 8G controller(DCSG01195653 Filter extra error message for frame allocation(DCSG01311743 NVMe device connected to PCIe switch is not discovered by controller firmware on boot up(DCSG01260624 BST Failure: CFGI Fault with Latest 7.23 XSD(DCSG01246068 Import certificate slot chain operation fails on SPDM enabled controllers(DCSG01200707 REST client does not reflect the latest drive firmware version after firmware update(DCSG01225086 On eight PHY SKUs, Firmware should disable PCIe packet processing for second SAS/PDB core.(DCSG01304303 Clean does not remove signing artifacts(DCSG01360624 Firmware console command 'pl eminfo' shows no PCIe support for a PCIe supported UBM backplane Device Face Connector.(DCSG01285442 PEX 89000: synthetic mode BST for B0 board(DCSG01236975 Uninitialized pointer access in UBM Backplane management code.(DCSG01225064 PEX89000: DevBst Fix for sensorDisplay CLI(DCSG01248992 Confusing ETTY prints near controller reset while creating R5 virtual disk with three drives(DCSG01383891 Build all is failed due to Error: NVDATA Major Versions do not match!(DCSG01258017 Missing stack frames when an exception occurs(DCSG01371672 MR_7.23: Storcli event during firmware upgrade needs correction.(DCSG01228280 observed when diagnostic register dump is performed while running IO to the drives. Description Of(DCSG01227332 [NVMe] Mode F Firmware download to certain NVMe drives fails.(DCSG01286617 Fix drive link speed reporting due to the fact that drive negotiated down link speed after initial link up(DCSG01288864 Missing fields in Manufacturing Page 7 in Snapdump(DCSG01321763 Running show security SPDM cmd failed(DCSG01349508 MegaRAID 7.22: Trying to validate DCSG01234817 and seeing similar issue and a hard hang(DCSG01363017 Target mode controller port width degrades following host resets/power cycles with autoport config disabled(DCSG01325599 PEX89000: Do not use use_frame_pointer compiler flag mbedTLS compilation(DCSG01282885 Fixes for the TTY Replace test case(DCSG01249618 Firmware summary notes needs to be updated to remove 94xx boards references(DCSG01271551 While generating the snapdump, firmware hit the data abort exception(DCSG01216058 (Port Of Defect DCSG01351467) Drive running sanitize overwrite becomes UBUnsp after a cold boot(DCSG01174553 (Port Of Defect DCSG01270388) Controller cache has been lost seen during Cache Offload Loop test(DCSG01108247 (Port Of Defect DCSG01166476) Assertion when playing copyback Write Journaling entries on warm reboot(DCSG01310309 (Port Of Defect DCSG01314116) [NVMe] Some NVMe drives do not link up on certain OEM backplanes.(DCSG01193134 (Port Of Defect DCSG01196465) MegaRaid7.23: firmware hit assertion failure memory.h at line 447: isInAddressibleRange(physAddrLow)(DCSG01310030 (Port Of Defect DCSG01322278) Firmware crashes after reconstruction completes and IO running(DCSG01292231 (Port Of Defect DCSG01301298) During OCR, a snapdump was generated by FW due to "Assertion failure in fw\hw\pbam\serial.c at line 2413: IntNesting==0"(DCSG01175907 (Port Of Defect DCSG01176190) MegaRAID 7.22: Trying to validate DCSG01234817 and seeing similar issue and a hard hang(DCSG01363017 (Port Of Defect DCSG01364478) Foreign Config import Error message not proper in HII(DCSG01089538 (Port Of Defect DCSG01301413) for JBODs, not setting physical drive state change committed bit in NVRAM.(DCSG01285247 (Port Of Defect DCSG01351187) MR_7.24: firmware fault on 9560 megaraid card upon malformed sense command(DCSG01331157 (Port Of Defect DCSG01351139) While setting WCE(Disk Write Cache)=0 for JBOD; Firmware throws error mode_sense_10 buffer requested 400 but available 4, command failed.(DCSG01365204 (Port Of Defect DCSG01365379) While generating the snapdump, firmware hit the data abort exception(DCSG01216058 (Port Of Defect DCSG01351468) Flash / upgrade from Release Order Package 4567 to Release Order Package 4601 failed on JBOD mode Ctrl (profile = 20)(DCSG01312941 (Port Of Defect DCSG01316809) Fix Kill Adapter when powering off one of the attached enclosures(DCSG01217941 (Port Of Defect DCSG01229838) While setting WCE(Disk Write Cache)=0 for JBOD; Firmware throws error mode_sense_10 buffer requested 400 but available 4, command failed.(DCSG01365204 (Port Of Defect DCSG01365380) IO tool fails while running IO and Online Controller Reset in a loop(DCSG01206038 (Port Of Defect DCSG01233670) Storcli hangs with no output after running script cleaning up debug variables.(DCSG01341519 (Port Of Defect DCSG01358591) Firmware crashes after reconstruction completes and IO running(DCSG01292231 (Port Of Defect DCSG01302229) IOC Page 7 does not report the updated "SASNotifyPrimitiveMasks"(DCSG01220829 (Port Of Defect DCSG01222353) SATA, Fault 0x5919 seen during write same error and task managements(DCSG01176562 (Port Of Defect DCSG01228270) Secured configured drives changing to unconfigured after reboot(DCSG01249672 (Port Of Defect DCSG01257018) Drive stays in UBAD state when doing running drive insertion/removal test(DCSG01349665 (Port Of Defect DCSG01372497) Drive running sanitize overwrite becomes UBUnsp after a cold boot(DCSG01174553 (Port Of Defect DCSG01270380) Controller fault observed while running cache offload cycles with heavy IOs(DCSG01342893 (Port Of Defect DCSG01351132) For un-configured bad foreign drive import and clear option buttons are visible in application(DCSG01315519 (Port Of Defect DCSG01351155) Erase operation fails on OEM specific UBM backplane during UBM controller firmware update.(DCSG01289710 (Port Of Defect DCSG01294066) Fix to handle TTY Flash with write error(DCSG01077025 (Port Of Defect DCSG01287096) Direct attached devices do not link up in case SEP backplane detection is configured in NVData(DCSG01285763 (Port Of Defect DCSG01286648) Assertion failure seen when expander resets and phy on & off executed in loop(DCSG01192071 (Port Of Defect DCSG01351483) Revert SATA Init timeout changes(DCSG01252414 (Port Of Defect DCSG01255751) Flash / upgrade from Release Order Package 4567 to Release Order Package 4601 failed on JBOD mode Ctrl (profile = 20)(DCSG01312941 (Port Of Defect DCSG01316817) Firmware flash followed by expander reset hit the Exception(DCSG01234817 (Port Of Defect DCSG01351403) MR_7.24: firmware fault on 9560 megaraid card upon malformed sense command(DCSG01331157 (Port Of Defect DCSG01351138) Fix Kill Adapter when powering off one of the attached enclosures(DCSG01217941 (Port Of Defect DCSG01229841) Change spinup mode while SATA link reset is occurring(DCSG01161733 (Port Of Defect DCSG01231494) for JBODs, not setting physical drive state change committed bit in NVRAM.(DCSG01285247 (Port Of Defect DCSG01351186) Firmware crashes after reconstruction completes and IO running(DCSG01292231 (Port Of Defect DCSG01301299) Update NVDATA Major version(DCSG01258013 (Port Of Defect DCSG01270040) For un-configured bad foreign drive import and clear option buttons are visible in application(DCSG01315519 (Port Of Defect DCSG01351156) NVMe response buffer differs from host for get smart health information(DCSG01118222 (Port Of Defect DCSG01376667) Sanitize (Block Erase) along with shutdown sequence caused assertion in firmware. (NVMe Only)(DCSG01358573 (Port Of Defect DCSG01371174) Foreign Config import Error message not proper in HII(DCSG01089538 (Port Of Defect DCSG01304258) Controller fault observed while running cache offload cycles with heavy IOs(DCSG01342893 (Port Of Defect DCSG01351130) Firmware flash followed by expander reset hit the Exception(DCSG01234817 (Port Of Defect DCSG01351402) Assertion when playing copyback Write Journaling entries on warm reboot(DCSG01310309 (Port Of Defect DCSG01314121) Import certificate slot chain operation fails on SPDM enabled controllers(DCSG01200707 (Port Of Defect DCSG01249471) Assertion failure seen when expander resets and phy on & off executed in loop(DCSG01192071 (Port Of Defect DCSG01351484) MegaRaid7.23: firmware hit assertion failure memory.h at line 447: isInAddressibleRange(physAddrLow)(DCSG01310030 (Port Of Defect DCSG01322276) Assertion when playing copyback Write Journaling entries on warm reboot(DCSG01310309 (Port Of Defect DCSG01314120) M.2 NVMe drive initialization failed after warm reset(DCSG01264359 (Port Of Defect DCSG01301951) [VSes] Number of slots reported incorrectly in certain OEM backplane.(DCSG01200427 (Port Of Defect DCSG01215896) EnhancementRequests: Use finalize bit hardware capability to generate SHA(DCSG01265112 Reduce On-Chip Memory Usage: NVME(DCSG01338107 Handle SED drive state when the drive get into AUTHORITY_LOCKED_OUT(DCSG00966551 SPILIB2: Add interrupt disable and clear to all init paths(DCSG01235869 Update Enterprise Key Management KEY FAILURE boot message description(DCSG01321257 Add new field overrideSlowArrayThresholds in XSD to enable or disable slow array logic(DCSG01289615 SBLIB: Add interface APIs to support Security Version(DCSG01239235 Added support for Extended Linear Address in hex image parsing for UBM6 backplane firmware update(DCSG01218275 Fix GET MCTP VERSION Response to Invalid Message Type Number(DCSG01207379 Add support for PCI Ids of OEM controllers(DCSG01218309 Add API changes to support option to filter spin up sense events through NVDATA field filterDSSpinUpEvents(DCSG01218513 Handle interrupted TTY reads when TtyLogInFlash is disabled(DCSG01245875 TLER (Time Limited Error Recovery) for MR7 Controllers(DCSG01063803 Add New field in NVDATA to enable or disable spin up sense events(DCSG01218525 Add New field in NVDATA to enable or disable spin up sense events(DCSG01218525 Messages does not differentiate in Device Manager Retry command for success and failure conditions(DCSG01320346 Add Missing PSoC Firmware Files for DCSG01291552(DCSG01301007 Aero - SecureBoot: Added debug messages to the ring-buffer when the FW download operation fails(DCSG01132478 Implement PCIe reference clock control in applications.(DCSG01232265 Code Coverage Improvement: Firmware changes to add Random Number tests to BST(DCSG01273668 Reduce On-Chip Memory Usage: AES(DCSG01345551 Reduce On-Chip Memory Usage: Megamon(DCSG01334551 Updated Package build option in release scripts(DCSG01360774 Adding a print string when LED blink status is set to BAD(DCSG00927793 Firmware: With TTYloginflash disabled, provide the eTTY log when the user requests for the term log(DCSG01187516 Qualify OEM BiCS5 flash devices for cache offload functionality(DCSG01311375 Reduce On-Chip Memory Usage: Hardware Tests(DCSG01334967 Reduce On-Chip Memory Usage: Diagnostics(DCSG01336164 Add support to change Enterprise Key Management support through command line(DCSG01155012 Modify the cache offload memory layout to support future NAND parts(DCSG01363836 Enhance Reconstruction error handling to avoid crash with invalid physical drive(DCSG01368554 Add a TtyReplace switch to NVDATA(DCSG01232969 Reduce On-Chip Memory Usage: Snapdump(DCSG01333402 Firmware: Enhanced NVMe Recovery Process(DCSG01220515 Add compiler version checking to the MegaRAID firmware build(DCSG01278550 iMR Snapdump: include Megamon commands in TTY Log(DCSG01365338 Adjust comment entry to match API changes(DCSG01229786 Update SPI Lib to latest(DCSG01215946 Reverting changes from ER DCSG01155012(DCSG01248730 [Code Coverage] Include CTC files in firmware code and create a build type that includes CTC code.(DCSG01132120 Reduce On-Chip Memory Usage: Enclosure(DCSG01345411 SBLIB: Add all OID compatibility algorithm to Avenger build(DCSG00346387 SPILIB2: Change build options to match firmware options(DCSG01171492 Add NVDATA bit for allow Enterprise Key Management enable/disable support(DCSG01218843 Add IO Unit page 13 handling to Block/Allow MPI functions(DCSG01214245 Reverting API change for external key management feature enable/disable support(DCSG01248890 Add a generic event to identify the reset type(DCSG01344405 API change to add more Enclosure subtypes to support OEM backplanes(DCSG01209717 Comment changes for TTY Replace(DCSG01272267 Re-enable SPILIB2 and Fix MPB Erase Issues(DCSG01200182 Code Coverage Improvement: add an ETTY test case(DCSG01356753 Add Firmware Version 3 for PartNumbers 25731 and 25931 to PSoC Catalog Image(DCSG01291552 Capture Event info as a part of Snapdump(DCSG00965557 [SNTL] Update SCSI Format Translation for NVMe devices(DCSG01137935 Add custom change number to MBEDTLS to track which version is in use.(DCSG01267947 Aero FW-Download: when writing bootloader to the main region, write the signature bytes last(DCSG01154887 OOB Debuggability improvement(DCSG01194531 Add Capability Bit for Driver Dump Mode Status to MFI_CAPABILITIES(DCSG01321223 SPILIB2: Read the ISSI function register on init to detect incorrect configurations(DCSG01288804 Unexpected Sense Codes related to Dimmer Switch should not be logged in cases where FW has spun down PD(DCSG01171916 Add Firmware Version 19 and 18 for New OEM PartNumbers 29652 and 32052 to PSoC Catalog Image (Part 1)(DCSG01350783 API change for Implementation of PCIe reference clock control from applications.(DCSG01286990 Code Coverage Improvement: clean up dead code in TTY and timer files(DCSG01269785 Add a TtyReplace switch to NVDATA(DCSG01232885 Reduce On-Chip Memory Usage: I2C(DCSG01345439 Add Firmware Version 10 for PartNumbers 6021, 14790, and 14798 to PSoC Catalog Image(DCSG01296892 Fix Part Number Header Verbiage(DCSG01375705 Generate a link speed change event for drives when the initially negotiated link speed gets changed(DCSG01348250 Removed OEM specific code(DCSG01187339 Handle PD Manual Status change while BGI/CC/INIT is active/Paused and adjust consistency status of LD(DCSG01188329 LED updates and VSES commands from host are blocked during UBM BP Firmware update(DCSG01187546 Upgrade ARM compiler version(DCSG01331364 SPDM library: Add support for SPDM v1.0(DCSG01137730 Add a new bit to parameter page 0(DCSG01224690 Capture additional controller info in Snapdump(DCSG01327223 Add ApSHA changes(DCSG01209350 Add new feature to enable or disable slow array logic in firmware(DCSG01272081 Add Firmware Version 17 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01314019 Reduce On-Chip Memory Usage: Drive Performance Monitor(DCSG01333825 Enable DS event filtering in firmware based on filterDSSpinUpEvents NVDATA setting(DCSG01226496 Firmware: Add DFT for Improve R1 Clustered Medium Error handling(DCSG01232890 Implement incomplete firmware handlers for the SCSI commands as per the latest SCSI NVMe Translation Layer spec - V1.08(DCSG01308277 API changes to set the default execution interval for Consistency check and patrol read through NVDATA(DCSG01358207 Add new interface APIs to Secure Boot Library(DCSG01099719 Add PEX89000 build support for libmbed tls.(DCSG01175822 Add an API to format the ETTY to a buffer(DCSG01208404 Updated release scripts for verifying Firmware build status(DCSG01350607 Revert NVDATA change for allow external key management feature enable/disable support(DCSG01248896 SPILIB2: Add FRAM support(DCSG01245618 Code Coverage Improvement: add the semaphore tests to BST(DCSG01270488 Run PEX89000 devBST on B0 board(DCSG01247942 SPDM 1.1 : Upgrade to MbedTLS version 2.26.0(DCSG01060374 Discontinue Firmware Release for 94xx Series of chips(DCSG01240537 Add support for OEM target for including the latest sblib(DCSG01263709 Enhance RMC log parser for new reference clock timeout(DCSG01315146 Remove custom library prefix from builds(DCSG01170510 SPILIB2: Integrate new 9700 series headers and add support for FRAM(DCSG01292279 Add new event for Physical Disk link speed change.(DCSG01327217 Firmware: Make autorebuild behavior consistent for end customers(DCSG01240282 Reduce On-Chip Memory Usage: Disk Encryption(DCSG01336490 Reduce On-Chip Memory Usage: Embedded CPU Debug(DCSG01334173 SPILIB: 97xx - Change dummy byte value to 0xFF's(DCSG01216772 Add Dummy Part Number Image to Catalog for Old 15987 Part Number PSoCs(DCSG01373884 Make adjustments for TTY Clear when TTYloginflash is disabled(DCSG01225741 Improve RLM operation time when no host IO activity is on going(DCSG01186257 Use event based wait for browser automation during release process(DCSG01133010 SBLIB: Clean up code for external use(DCSG01150489 Added Enable Enterprise Key Manager Support bit to MegaRaid CTRL_PROP(DCSG01208216 Firmware: Prevent installation of inappropriate FW image on Intel branded MR/iMR adapters(DCSG01272302 PLDM single image support(DCSG01249347 Enhance SuperCap Relearn Logic to Not Prematurely Set App Learn Failures and Timeouts(DCSG01383159 Firmware: SPDM Support for 954x boards(DCSG01311369 Firmware: Improve R1 Clustered Medium Error handling(DCSG01187519 Add support for OEM UBM backplane(DCSG01209669 Add Firmware Version 4 for PartNumber 15463 to PSoC Catalog Image(DCSG01378374 SCONS: Update the back trace symbol generator so that it supports unlimited symbols(DCSG01230985 Code Coverage: improved error handling when dumping counters(DCSG01224606 Reduce On-Chip Memory Usage: Constants(DCSG01342382 SBLib: Add API to discern whether the EFUSE is full(DCSG00989785 Firmware: Implement REFCLK control in HII(DCSG01291368 Reduce On-Chip Memory Usage: Strings(DCSG01337295 PEX89000: Add configuration for the PEX89000 B0 BST setup(DCSG01256006 Build Improvement: clean needs to apply to debug builds as well(DCSG01300541 MegaAPI: Add API Controller Properties for overriding slow array thresholds(DCSG01288908 Add Firmware Version 19 and 18 for New OEM PartNumbers 29652 and 32052 to PSoC Catalog Image (Part 2)(DCSG01350841 PLDM - Add UBM firmware update changes under the compilation macro(DCSG01250826 Update Aero iMR/MR to the latest secure boot library(DCSG01198693 Leverage Driver Dump Mode bit in MFI_CAPABILITIES to determine if host is in dump mode(DCSG01344379 Code Coverage: build changes to verify that supported tools are being used(DCSG01254595 Reverting XSD change for external key management support feature(DCSG01248908 PL Firmware: SFF-TA-1005 Version 1.4 Support(DCSG01214256 Added a generic event to identify the reset type.(DCSG01315620 Add API changes to support slow array logic override through NVDATA field overrideSlowArrayThresholds(DCSG01289475 Update config file for PEX89000 A0 devBST(DCSG01235384 Support SPDM v1.0 for OEM controllers(DCSG01135013 Firmware: Add a SAS/SATA only profile(DCSG01311360 Add Electrical Information to Cache Offload Info Dump(DCSG01327220 Revert Port Name Changes in Redfish Events(DCSG01187327 Firmware: Support Long Lock Delay Times when Negotiating to a 6G SATA Drive at 3G(DCSG01253833 Add Firmware Version 18 for PartNumbers 29211, 29651, and 29810 to PSoC Catalog Image(DCSG01345892 Enhancement in preserving NVRAM settings in snapdump(DCSG01289418 Update SB Lib to latest(DCSG01224363 SPDM: Upgrade the latest SPDM Library in PH26(DCSG01219141 Improve iMR null pointer handling so that exceptions are generated(DCSG00996946 Capture physical drive and logical drive allowed operations in Snapdump(DCSG01327224 PL firmware workaround for UBM Backplane firmware flashing issue in OEM specific Backplane(DCSG01237118 (Port Of EnhancementRequest DCSG01252393) PL: Enable the UBM firmware update support for OEM specific UBM backplane.(DCSG01233264 (Port Of EnhancementRequest DCSG01252355) Firmware: Add a SAS/SATA only profile(DCSG01311360 (Port Of EnhancementRequest DCSG01378362) Firmware: Add a SAS/SATA only profile(DCSG01311360 (Port Of EnhancementRequest DCSG01350767) IOP: Rework MCTP packet validation code for workaround for some multi-segment servers(DCSG01289379 (Port Of EnhancementRequest DCSG01328386) [9500] Add support for host phys/lanes in Port Status Green GPIO(DCSG01207029 (Port Of EnhancementRequest DCSG01251940) Add support for new product specific MCTP Event(DCSG01149990 (Port Of EnhancementRequest DCSG01268764) Enhance Reconstruction error handling to avoid crash with invalid physical drive(DCSG01368554 (Port Of EnhancementRequest DCSG01370842) Add support for OEM specific SAS 4 expander based enclosure with 950x controllers(DCSG01351490 (Port Of EnhancementRequest DCSG01363691) Version 52.22.0-4775 - Moderate Impact/Low Probability of Occurrence ------------------- BIOS:7.22.00.0 UEFI Driver:0x07160300 HII: 07.22.03.00 IMR FW: 5.220.01-3784 package 52.22.0-4775 MR 7.22 Defects: -Copyright year needs to be corrected in ROC firmware print.(DCSG01396947) -Locate LED operation does not work for NVMe drive slot on UBM backplane.(DCSG01230479) -Updated the forceUpdate format in PLDM header generation Tool.(DCSG00106563) -Locate LED operation does not work for NVMe drive slot on UBM backplane.(DCSG01230479) -WriteCache RDE alerts are logged irrespective of the volume cache policy(DCSG01088107 -RDE - REST client displays the controller cache state as 'Disabled' instead of 'UnavailableOffline' when a failed energy pack is connected(DCSG01093471 -Aligning RDE Port MaxSpeedGbps per the latest spec(DCSG01098703 -RDE Port Schema CurrentSpeedGbps property to be populated with aggregate of current speeds of connected devices(DCSG01098717 -RDE_VolumeSchema-Encryption and EncryptionType to be displayed conditionally(DCSG01098912 -RDE - Encryption Status drive resource property must be displayed if the drive is a Self Encrypting Drive(DCSG01098917 -RDE VolumeSchema - WriteHoleProtectionPolicy to be conditional for Raid types that use Write Journaling(DCSG01102935 -Fix sliced LD secure erase resume after power cycle or OCR(DCSG01107534 -RDE Port Schema: CurrentSpeedGbps and MaxSpeedGbps shown as a negative value(DCSG01108315 -Redfish NVMe DurableName to be displayed in IEEE-defined 64-bit Extended Unique Identifier (EUI) format(DCSG01111791 -make all is compiling now(DCSG01111915 -RDE : Volume schema WriteCacheState property changed to "Degraded" during volume Transformation(DCSG01113836 -RDE Volume Schema - State of Volume changed to 'Updating' while rebuilding(DCSG01120814 -RDE Read Compliance-Drive Schema Health changed to "Critical" and Status indicator to "Fail", when a Predictive Failure drive is made Offline(DCSG01120819 -LED updates and VSES commands from host are blocked during UBM BP FW update(DCSG01123121 -RDE : Volume schema InitializeMethod property should not show "Foreground" for Volume Erase Operation(DCSG01124997 -UBM Ctrl FW update - Block host request OCR(DCSG01132889 -Redundant Microcode update Complete event avoided - Restricting and Un-restricting PD during UBM Ctrl FW update is removed(DCSG01135144 -Corrected UBM Ctrl FW update Abort response to populate appropriate event(DCSG01143009 -UBM firmware update not happening on one out of two UBM controllers while rebuild operation was in progress(DCSG01148879 -ONLINE LED and Predictive Failure LED to be ON for specific OEM(DCSG01152693 -Updated EstimatedTimeBeforeSendingRequestFirmwareData(DCSG01155398 -Error values during PMSM preserved correctly(DCSG01155732 -Cancel update command response is set appropriately in the shim layer(DCSG01158535 -iMR 7.22 exceeds Max 8 SAS/SATA drives when more drives are inserted and they become Jbod.(DCSG01166723 -MR card failed to expose drives in Linux kdump(DCSG01170243 -PLDM Type 5 support for Downstream device enablement based on library support(DCSG01172419 -MR7.22PA1_Need to add bootKeyHalt to 0 for excessive drives(DCSG01173927 -Updated the common structure member values ,which are used during UBM BP update and MR controller FW update.(DCSG01175633 -Perc 11.4: During OCR, a snapdump was generated by FW due to "Assertion failure in fw\hw\pbam\serial.c at line 2413: IntNesting==0"(DCSG01175907 -MR7.22-Resetnow should be blocked for PSOC updates(DCSG01181534 -MR 7.22 PA2: 433T PSOC can't be flashed via storcli due to PN mismatch(DCSG01183086 -Configuration not exposed by MR on windows OS when device order is enabled(DCSG01184008 -MR FW not responsive to host interface after returning success to stop BGI / CC of an offline VD(DCSG01185811 -PEX88000 - Issue NF error to NIC card resulted in system crash(DCSG01186408 -fix sanitize block erase support on NVMe drive(DCSG01187755 -Firmware reports dirty cache lost in the UART log(DCSG01191291 -Assertion failure seen when expander resets and phy on & off executed in loop(DCSG01192071 -Assert Audit: fix printing when the analysis is restarted(DCSG01196023 -Code Coverage: fix SPDM path list in codeCoverageTool.py(DCSG01196255 -[VSes] Number of slots reported incorrectly in certain OEM backplane.(DCSG01200427 -Sanitize option seen in Apps when a drive is spundown by user(DCSG01201754 -While generating the snapdump, firmware hit the data abort exception(DCSG01216058 -Fix Kill Adapter when powering off one of the attached enclosures(DCSG01217941 -Firmware flash followed by expander reset hit the Exception(DCSG01234817 -PEX 89000: synthetic mode BST for B0 board(DCSG01236975 -Enclosure location is showing as "Internal" in LSA for Vses(DCSG01245355 -BST Failure: CFGI Fault with Latest 7.23 XSD(DCSG01246068 -PEX89000: Fix function parenthesis in packet generator functions(DCSG01247963 -Secured configured drives changing to unconfigured after reboot(DCSG01249672 -Controller hit Fatal error with exception when run PR and CC at same time(DCSG01267776 -Skip Enclosure Power Cycle test for OEM BST as it is not relevant and results in failure(DCSG01303587 -System restarts by itself and PL Fault 00005854 LinkRegister 01475093(DCSG01304319 -Enable the TTY Replace setting in NVDATA(DCSG01333745 -Fix wrong consistency state of Single drive R0 after setting physical drive offline then online(DCSG01141800 -MR7.21: Flash erase errors(DCSG01148422 -7.21 : Test bad flash in Megamon, found FW hit KA(DCSG01140493 -MR 7.21 Ventura FW Pk 4350 stops dumping data in FW log during OCR.(DCSG01156781 -Fatal firmware error detected after converted SATA SSD PD to JBOD(DCSG01112314 -CSCwb37148: SPDM programming got wiped out from Wlbur+Samishlake: Storage operations are failing.(DCSG01179653 -The Fault LED is on for the expander attached pre-failure EPD drive when rebooting the system(DCSG01172493 -FW logging CDB failure sense event twice for each failure(DCSG01149411 -[NVMe] Some NVMe drives do not link up on certain OEM backplanes.(DCSG01193134 -OOB SL\SLT NVMe Passthru : NVMe response buffer differs from host for get log information command for NVMe drives(DCSG01147859 -Unconfigured Bad SAS SSD drive is showing Media as HDD in LSA/Storcli(DCSG01196368 -Fix for the MPB test(DCSG01209348 -IO tool fails while running IO and Online Controller Reset in a loop(DCSG01206038 -[SATA] SATA Initialization fails on certain large capacity SATA drives(DCSG01194600 -Locate LED operation does not work for NVMe drive slot on UBM backplane(DCSG01230479 -Import certificate slot chain operation fails on SPDM enabled controllers(DCSG01200707 -Drive running sanitize overwrite becomes UBUnsp after a cold boot(DCSG01174553 -Fix to handle TTY Flash with write error(DCSG01077025 -Firmware crashes after reconstruction completes and IO running(DCSG01292231 -Foreign Config import Error message not proper in HII(DCSG01089538 -Assertion when playing copyback Write Journaling entries on warm reboot(DCSG01310309 -Flash / upgrade from Release Order Package 4567 to Release Order Package 4601 failed on JBOD mode Ctrl (profile = 20)(DCSG01312941 -Strocli show command displays incorrect number of physical drives count(DCSG01293599 -MegaRaid7.23: firmware hit assertion failure memory.h at line 447: isInAddressibleRange(physAddrLow)(DCSG01310030 -For un-configured bad foreign drive import and clear option buttons are visible in application(DCSG01315519 -Controller fault observed while running cache offload cycles with heavy IOs(DCSG01342893 -MR_7.24: firmware fault on 9560 megaraid card upon malformed sense command(DCSG01331157 -for JBODs, not setting physical drive state change committed bit in NVRAM.(DCSG01285247 Enhancements: -Single PLDM fw update file that covers all controllers from that series.(DCSG00019356) -UBM Controller Firmware Update support(DCSG01016704 -Aero - Shim layer support for PLDM Type 5 UBM Backplane Firmware Update(DCSG01070579 -Aero 9540 iMR controllers - Support for multiple PSOC images(DCSG01076542 -Parses the UBM FW image file(DCSG01080232 -shim layer changes for prepare and download(DCSG01083777 -Aero - Block SES monitoring and locate LED functionalities when UBM backplane firmware update is in progress(DCSG01088688 -Make branding compliance changes for new features including Sanitize support(DCSG01090347 -Allow FW downgrade for shenandoah(DCSG01093455 -New PNP ID addition(DCSG01101846 -RDE Read Compliance - Align to the latest Spec(DCSG01107680 -Calculate downstream devices length of QueryDownstreamIdentifiers command(DCSG01108419 -PLDM Type 5 - Set Downstream Device Component Update Failure Recovery Capability parameter of GetDownstreamFirmwareParameters command to 0(DCSG01123160 -Shim layer changes to add Vendor Defined descriptor support for PLDM FW update UBM Ctrl Downstream Device(DCSG01128935 -Reduce eTTY and Binary Trace Logic Stack Usage(DCSG01139030 -Add Additional PSoC 4 FWs to Catalog File(DCSG01157615 -Remove custom library prefix from builds(DCSG01170510 -97xx: SCONS changes are required for loading 97xx SBR(DCSG01171935 -Remove PSoC 5 OCP PSoC FW from Catalog Releases(DCSG01175916 -Check-in Cypress License Agreement into MR Cypress Code Tree(DCSG01177646 -Add Firmware Version 13 for PartNumber 29810 to PSoC Catalog Image(DCSG01179045 -Code Coverage Improvement: better handling of long strings in ETTY(DCSG01179424 -Reduce _vnprintf stack usage(DCSG01186456 -Code Coverage Improvement: Adjust Preprocessing in Snapdump(DCSG01194315 -Code Coverage: Add MPB test status(DCSG01195938 -Code Coverage Improvement: exclude development only functions(DCSG01196166 -Code Coverage: allow tools to be in other directories(DCSG01196286 -Add message when invalid phy is passed to get connector index(DCSG01197627 -Code Coverage: support all build target(DCSG01197780 -Code Coverage: support all build target -- fw_bld_tools(DCSG01199258 -Update OEM specific BST scripts to include mainline changes.(DCSG01200062 -Add New PSoC 5 OCP Channel and Megacell and PSoC 6 BGA Megacell Releases to PSoC Catalog Image(DCSG01203313 -Add Firmware Version 15 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01208354 -Add Firmware Version 16 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01209445 -Code Coverage Improvement: remove some constants from the Snapdump symbol file(DCSG01209495 -Updated OEM auto bst scripts(DCSG01212778 -Add API changes to support option to filter spin up sense events through NVDATA field filterDSSpinUpEvents(DCSG01218513 -Add New field in NVDATA to enable or disable spin up sense events(DCSG01218525 -Add NVDATA bit for allow Enterprise Key Management enable/disable support(DCSG01218843 -PEX89000: Add PEX89000 packet generator support to DevBst(DCSG01223198 -Add a new bit to parameter page 0(DCSG01224690 -SCONS: Update the back trace symbol generator so that it supports unlimited symbols(DCSG01230985 -Add a TtyReplace switch to NVDATA(DCSG01232885 -Add a TtyReplace switch to NVDATA(DCSG01232969 -Update config file for PEX89000 A0 devBST(DCSG01235384 -Run PEX89000 devBST on B0 board(DCSG01247942 -Revert NVDATA change for allow external key management feature enable/disable support(DCSG01248896 -Reverting XSD change for external key management support feature(DCSG01248908 -PLDM single image support(DCSG01249347 -PEX89000: Add configuration for the PEX89000 B0 BST setup(DCSG01256006 -Firmware: Prevent installation of inappropriate FW image on Intel branded MR/iMR adapters(DCSG01272302 -Add API changes to support slow array logic override through NVDATA field overrideSlowArrayThresholds(DCSG01289475 -Add new field overrideSlowArrayThresholds in XSD to enable or disable slow array logic(DCSG01289615 -Add Firmware Version 3 for PartNumbers 25731 and 25931 to PSoC Catalog Image(DCSG01291552 -Add Firmware Version 10 for PartNumbers 6021, 14790, and 14798 to PSoC Catalog Image(DCSG01296892 -Add Missing PSoC Firmware Files for DCSG01291552(DCSG01301007 -Optimize the default Consistency check and patrol read settings for decreasing the workload on drives(DCSG01339902 -Add Firmware Version 19 and 18 for New OEM PartNumbers 29652 and 32052 to PSoC Catalog Image (Part 1)(DCSG01350783 -API changes to set the default execution interval for Consistency check and patrol read through NVDATA(DCSG01358207 -Add new field consCheckAndPatrolReadExecFreq in XSD file to set the default execution interval for Consistency check and patrol read through NVDATA(DCSG01360727 -Spin up recovery. changes for supporting OEM drive issue(DCSG01168828 -PLDM library support on Aero iMR controllers(DCSG01176360 -Firmware: Add a SAS/SATA only profile(DCSG01311360 Version 52.22.0-4564 - Moderate Impact/Low Probability of Occurrence ------------------- BIOS:7.22.00.0 UEFI Driver:0x07160300 HII: 07.22.03.00 IMR FW: 5.220.01-3694 package 52.22.0-4564 MR 7.22 Defects: -Unconfigured Bad SAS SSD drive is showing Media as HDD in LSA/Storcli.(DCSG01196368) -Fix Kill Adapter when powering off one of the attached enclosures.(DCSG01217941) -Firmware flash followed by expander reset hit the Exception.(DCSG01234817) -Enclosure location is showing as "Internal" in LSA for Vses.(DCSG01245355) -PEX89000: Fix function parenthesis in packet generator functions.(DCSG01247963) -Release Note update for Downgrade firmware from 7.22 to & 7.2x.(DCSG01270046) -IO tool fails while running IO and Online Controller Reset in a loop.(DCSG01206038) -Import certificate slot chain operation fails on SPDM enabled controllers.(DCSG01200707) -[VSes] Number of slots reported incorrectly in certain OEM backplane..(DCSG01200427) -Updated the forceUpdate format in PLDM header generation Tool.(DCSG00106563) -Controller Missing on some Power Cycle iterations.(DCSG01233716) -[VSes] Number of slots reported incorrectly in certain OEM backplane..(DCSG01200427) -Fix return status when there is no more target ID available at auto config.(DCSG01140002) -Controller marks a drive UBUnsp if the server is rebooted while running Sanitize Overwrite.(DCSG01141274) -Firmware hang observed during controller boot.(DCSG01142137) -[Aero][SNTL] SNTL Generic command Status successful completion with no SenseKey is sending.(DCSG01146888) -MR7.21: Flash erase errors.(DCSG01148422) -Fix the check blocking FDE drive on Sanitize.(DCSG01156368) -MR 7.21 Ventura FW Pk 4350 stops dumping data in FW log during OCR.(DCSG01156781) -Fail the UBM firmware update request gracefully if Programming Update is not supported by the.(DCSG01159186) -[Aero] "Couldn't init SBLI" error print seen in firmware uart during controller boot up.(DCSG01161361) -Data Miscompare observed with sliced R5 Logical Drives during write(cache) policy change.(DCSG01161554) -Update the error code when there is no target ID available for auto config EPD.(DCSG01163316) -Generate BootMsg when more than 4 NVMe drives is inserted in the boot cycle at profile 41 for iMR.(DCSG01165091) -Fix wrong persistent dev id due to profile change.(DCSG01166149) -Aero iMR: FW did not block downgrade from MR7.22 (profile 41) to MR7.21 causing CTRL into safe mode.(DCSG01169605) -NVMe drives behind 9460-16i controller doesnt discover on SOD.(DCSG01172751) -Fix persistent Id clearing when profile is not changing.(DCSG01175414) -Firmware asserts when reading the UBM backplane information and UBM controller firmware update in progress.(DCSG01132100) PL is not returning proper sense information as part of UBM controller firmware update failure reply..(DCSG01145707) -PL fails to report the UBM controller firmware update failure after receiving the bad checksum.(DCSG01148192) -Controller cache has been lost seen during Cache Offload Loop test.(DCSG01108247) -Discovery times out when connected to UBM backplane with x4 link width..(DCSG01165227) -Secure erase is not working properly for UG Bad drive.(DCSG01106797) -Diff drives shows as UG and sector size 0/blank in BRCM applications.(DCSG01145221) FW asserts on executing scrutiny phy -speed command.(DCSG01089818) -Support NVMe Width is displayed as "Yes" for RAID 940-8e controller.(DCSG01119307) -Phy bad events seen for one of the Enclosure Valid Slot.(DCSG01088807) -Updated the forceUpdate format in PLDM header generation Tool.(DCSG00106563) Enhancements: -Remove custom library prefix from builds.(DCSG01170510) -SCONS: Update the back trace symbol generator so that it supports unlimited symbols.(DCSG01230985) -Update config file for PEX89000 A0 devBST.(DCSG01235384) -Blocking at MR FW and graying out at applications for changing the link speed for any UBM behind drives.(DCSG00950267) -Add multiple SPI device access devBST tests on SPI0.(DCSG01003421) -Partial configuration import events and messages in the utilities..(DCSG01070721) -Cosim BST: Update the FW package content for file name changes (pci4armfw => pcifw).(DCSG01132044) -Code Coverage: build improvements.(DCSG01135245) -Create OEM PSoC FW Based Catalog File.(DCSG01136930) -Update Atlas2 devBST script with filename changes.(DCSG01137350) -PEX89000 BST ER: Two host flash boot feature BST Evaluation for COSIM.(DCSG01138480) -Add PSoC Image Checking and FW Blocking for Aero iMR(DCSG01153976) -Update PSoC MR FW Downgrade Block MFI_STAT to be More Clear.(DCSG01155856) -Add Firmware Version 12 for PartNumbers 29211 and 29651 to PSoC Catalog Image.(DCSG01159010) -Update link speed control bit in SAS PHY connection structure.(DCSG01164061) -97xx: SCONS changes are required for loading 97xx SBR.(DCSG01164951) -Add Firmware Versions 27 and 1 for PartNumbers 15987 and 25731 to PSoC Catalog Image.(DCSG01166118) -Make API changes for new event FOREIGN_CFG_NON_IMPORTABLE_FOUND.(DCSG01168924) -Code Coverage Improvement: update command line parsing in cfgi.(DCSG01169587) -Code Coverage: add an identifier when dumping coverage data.(DCSG01170508) -SPILIB2: 9700 Series core needs maximum continuous count initialized earlier.(DCSG01170965) -SPDM 1.1 - Validate Certificate Chain during import operation.(DCSG01096875) -Single PLDM fw update file that covers all controllers from that series.(DCSG00019356) Version 52.20.0-4375 - Moderate Impact/Low Probability of Occurrence ------------------- BIOS:v7.20.01.0 UEFI Driver:0x07140000 HII: 07.20.07.00 IMR FW: 5.200.01-3637 package 52.20.0-4375 MR 7.20 Defects: Fix read wrong config page for NVMe drive behind Atlas(DCSG00954454 SL OOB: NVME response buffer is not displaying user requested size of response buffer.(DCSG01151757 MR7.20_Ventura+Windbond_CV learn fails(DCSG01127762 MR_7.20 missing VD's after OCR and enclosure Pull/Push(DCSG01061674 Remove SPDM debug logs from UART print(DCSG01022803 [3408+ MR7.16] configurablePDCount would exceeded if set jbod on while UG drives are in spundown.(DCSG01032834 FW hits KA when OCR Ctrl has pinned cache, while controller in Safe Mode(DCSG01061904 CC pause and resume with OCR restarts the CC on VDs that have already completed CC(DCSG01047837 MR7.19: Aero Ctrl global fault LED is not ON when there is unconfig_bad drive on the Ctrl(DCSG01027566 iMR 7.20 FW keeps dumping a message to FW log for Encs "Analyzing Status Page"(DCSG01025079 VSES : Multiple elements of SES page 0xA are assigned the same slot number(DCSG00973316 Fix a math error in the Memory Pool creation firmware(DCSG01024464 Performance drop seen with direct attached SAS/SATA drives(DCSG00980873 Foreign drive import command was successfully executed, but the drive is still marked as a foreign drive(DCSG01039809 PD Power State Set DCMD interface does not spin up Hot spare drives(DCSG01091672 21B Alpha LSA: Foreign VD's, VD1 and VD2 names are not displayed in foreign config preview page.(DCSG00927138 Performance drop seen with SAS/SATA drives in Windows using latest driver(DCSG00981706 MR 7.20 PA2: truncated coverage data(DCSG01040242 Reinstate ER 1010648(DCSG01025061 FW Logs/termlogs should change the Copyright 2017-2022(DCSG01116760 Blue Screens while collecting "pl dbg" logs(DCSG00984451 22B:PSOC6 -PSOC download/flash fails having Cv/BBU in failed (bad) state(DCSG01140342 UBM statistics data collection and UBM error handling fixes(DCSG00975065 Atlas2 Veloce BST: Wait till MPT driver load complete in single host MPT testcase(DCSG01087297 Unable to change current behavior mode to NONE from RAID-0 in JBOD personality(DCSG00970577 Update SSUTimeout Fields Value in BIOS Page 1 to 0xF0(DCSG00982364 Clearing the tty history with cli delete termlog command causes firmware to hang(DCSG01098208 Coverity : Remove dead code(DCSG00982343 Support NVMe Width is displayed as "Yes" for RAID 940-8e controller(DCSG01119307 Fix MCTP flash firmware issue(DCSG01098220 No Default value of DMA FIS Timeout(DCSG01028477 Secure erase is not working properly for UG Bad drive(DCSG01106797 MR7.20: Found a lot prints "C0:MfgMsg: Error reading device chemistry. I2C Error = 0x2" while PR(DCSG01044765 MR7.19PA1_After COL locked VD fails to import after becoming unlocked(DCSG00962887 Diff drives shows as UG and sector size 0/blank in BRCM applications(DCSG01145221 Fix controller does not show foreign config and pinned cache correctly(DCSG01050353 Expander show status is being marked unsupported in megaraid and switch configurations(DCSG00958041 Imbalanced bandwidth performance with 2 x4 expanders connect to Aero IT controller(DCSG00950631 Copyback status is displayed post clearing configuration(DCSG01039193 FW asserts on executing scrutiny phy -speed command(DCSG01089818 Firmware assertion while performing firmware download using offline method on PCIe switch configuration(DCSG00956089 MR 7.20 PA2: Code coverage code stuck printing forever(DCSG01031802 Drive secured by non-MR FW owner does not show as "locked" when place behind Mercury OEM controller(DCSG01058849 7.21: A hang is seen when attempting to update the the psoc using a catalog file when storcli does not support, but FW does.(DCSG01093791 AeroMR_7.20PA:Storcli Hangs on triggering controller restart and fails to exit command prompt(DCSG01040153 MR719_PA1_MA drive become jbod(Unsupported) and IO will run on them(DCSG00957470 PD state change reported only once when copyback is suspended and resumed(DCSG01081139 Hot add drive on UBM backplane with x2 or X4 DFC reports incorrect element status in SES Page 02h(DCSG00967012 MR7.20-iMR-Multi-LUN / Multi-Actuator drives show up as good(DCSG01024028 Fix response to setting JBOD for unsupported drive(DCSG01041383 [Aero] PCIe Compliance Configuration Failure - 1_44 DPA Ext Cap Struct(DCSG00972342 ScrutinyCLI in UEFI mode failed to download Aero MR NOPAD images using hostboot (hb) command(DCSG00984134 BST Failure: Revert defect 1010648(DCSG01021874 Update BinToRom.exe to match updated BinToRom.c(DCSG01082490 Added "TimeSyncInterval" to the FW ManPage11 data-struct to match the XSD definition(DCSG01041327 MR_7.20:VD target IDs changing during foreign config import - DC observed on running IOs post VD import(DCSG01045309 FW Fault 2622 observed during system boot up in some new Gen4/Gen5 servers(DCSG00947451 FW not setting Opal MSID password length properly when resetting password to MSID(DCSG01042567 Remove deprecated Vision builder(DCSG01078124 MR7.20-Discrete part iMR controller allows PSOC flashing(DCSG01066232 RefClk enabled for sgpio backplane type(DCSG00995519 NVMe response buffer differs from host for get smart health information(DCSG01118222 Firmware asserts during OCR with JBOD auto creation(DCSG01074021 Fix Missing OCP ROMs Copy Back(DCSG01093193 VPD data printed on every reboot(DCSG01035788 MR 7.18: Secure drives creation using multiple secure key unable view and import the first removed encrypted VD until the second VD has been imported.(DCSG00924602 VD Failure while updating Drives(DCSG01116221 Integrate IT Security Page Fixes into MR(DCSG01030957 Update Version Field value in Std Inquiry Data of vSES Device(DCSG00966397 BST Failure: Update ManPage11 for Phase 21 PL(DCSG01027882 Fix to handle TTY Flash with write error(DCSG01077025 MR 7.20: Json Event long message for missing PD needs to be updated(DCSG01040031 Phy bad events seen for one of the Enclosure Valid Slot(DCSG01088807 Fix too many debug messages(DCSG01032533 Data Abort exception happened during journaled writes(DCSG01113159 Fix EPD boot disk not available at legacy BIOS(DCSG01111179 (SATA Only) Inquiry command to read Block device Characteristics VPD Page fails on some SATA drives(DCSG01025293 Two elements of SES Page A are assigned same slot number for UBM backplanes with x2 DFC(DCSG00966202 Fatal firmware error detected after converted SATA SSD PD to JBOD(DCSG01112314 Critical Error Log created if the Firmware Download of BIOS using BIOS image from different package than Firmware.(DCSG00951807 Fix Delayed Expansion Issue in add_catalog_rom.bat(DCSG01092304 Update the Default Vendor ID of Virtual SES Device(DCSG01012204 Unsupported MPI Config page read from OOB provides data in response(DCSG00937617 Drives not discovered when an enclosure is hot plugged after removing a PCIe switch based JBOF(DCSG00957168 EPD is not created after import with escrow if escrow key matches controller key(DCSG00968394 FW asserts when try to create secured VDs using a FDE drive(DCSG01138487 Patrol read fails to correct medium error on verify capable NVME drives(DCSG01055287 Fix unmap writesame for a NVMe drive with small max data buffer length(DCSG00972351 SATA only : ATA PT command for SMART READ ATTRIBUTE THRESHOLDS(B0h/D1h) fail when COUNT field is set to 0(DCSG01030777 Autoconfig fails to create R0 or EPD on eligible drives in presence of Multi-Lun drives.(DCSG01030203 When read termlogs observing Copyright as 2017-2018 which needs to be changed to 2017-2021(DCSG00960207 Data Miscompare observed with sliced R5 Logical Drives during write(cache) policy change(DCSG01161554 Drive changes from UG to UB, when user start the initialization followed by secure erase on same drive(DCSG00837473 (Port Of Defect DCSG00946483) MR7.20: Found a lot prints "C0:MfgMsg: Error reading device chemistry. I2C Error = 0x2" while PR(DCSG01044765 (Port Of Defect DCSG01077927) Patrol read fails to correct medium error on verify capable NVME drives(DCSG01055287 (Port Of Defect DCSG01078110) Fixed fault 0xF000 when doing VSES task management(DCSG00927996 (Port Of Defect DCSG00934187) Boot message "Error restoring offloaded cache" popup for 940 card w/o SuperCap during AC power cycles(DCSG01087695 (Port Of Defect DCSG01116312) Connector name in SAS Device Page 0 of the VSes/DA-SEP is not set correctly(DCSG00995575 (Port Of Defect DCSG01003869) SPDM key reading failed when complete flash Erase case(DCSG01032600 (Port Of Defect DCSG01032601) Incorrect PLDM firmware release date is displayed in BMC applications(DCSG00926179 (Port Of Defect DCSG00966522) FW hits an ERROR: Exception Handler EXCEPTION during reboot of a server with PCIe gen5(DCSG01097640 (Port Of Defect DCSG01107907) Aero 7.19 iMR: CBB unable to find secondary image(DCSG00987835 (Port Of Defect DCSG01038387) BMU set startlearntime does not set properly(DCSG00917983 (Port Of Defect DCSG00991775) Fault 0xEE19 observed while running lane break test with managed switch attached to controller.(DCSG00939163 (Port Of Defect DCSG00947866) KeyID is cleared before the transition is finished(DCSG00936150 (Port Of Defect DCSG00977211) NVRAM signature invalid. Aborting DDR scrub & ECC check!!!(DCSG01111513 (Port Of Defect DCSG01126920) FW asserts when try to create secured VDs using a FDE drive(DCSG01138487 (Port Of Defect DCSG01148515) MCTP : MCTP MPI requests are failed with drive missing status even when drive is present(DCSG00952803 (Port Of Defect DCSG00956655) SATA : one or more HDD are not discovered by OS when drives behind expander are powered ON(DCSG00947126 (Port Of Defect DCSG00964427) 7.21: A hang is seen when attempting to update the the psoc using a catalog file when storcli does not support, but FW does.(DCSG01093791 (Port Of Defect DCSG01099363) Incorrect slot number reported for drive with bad Phy(DCSG00986779 (Port Of Defect DCSG00989522) [3408+ MR7.16] configurablePDCount would exceeded if set jbod on while UG drives are in spundown.(DCSG01032834 (Port Of Defect DCSG01044605) Bad sensor slot case should not counted again when marking slot bad.(DCSG00961696 (Port Of Defect DCSG00977229) SATA drive is not detected during hot plug test(DCSG00975159 (Port Of Defect DCSG01062363) NOTIFY(ENABLE SPINUP) is not sent to spin up legacy SAS drives when partial/slumber mode is enabled.(DCSG01044213 (Port Of Defect DCSG01137571) VD Failure while updating Drives(DCSG01116221 (Port Of Defect DCSG01124651) DMA error observed during xtools 'show' command in Atlas behind Aero config(DCSG01051896 (Port Of Defect DCSG01079552) NVME EPDs, with heavy IOs and TM from host side and NVMe passthru commands in loop from OOB. After 5-8 hrs hit KA(DCSG00939439 (Port Of Defect DCSG00970531) Secure erase is allowed on JBOD/EPD(DCSG00840773 (Port Of Defect DCSG00970537) Some drives missing in OS when Direct attached slot order event replay flag is set in NVDATA(DCSG00991409 (Port Of Defect DCSG00996085) Log Power State Change event for Hot spare drives spun up using MR_DCMD_PD_POWER_STATE_SET DCMD(DCSG01137533 (Port Of Defect DCSG01138265) Firmware asserts during OCR with JBOD auto creation(DCSG01074021 (Port Of Defect DCSG01091678) FW Logs/termlogs should change the Copyright 2017-2022(DCSG01116760 (Port Of Defect DCSG01119586) FW hits an ERROR: Exception Handler EXCEPTION during reboot of a server with PCIe gen5(DCSG01097640 (Port Of Defect DCSG01107908) MR_7.20 missing VD's after OCR and enclosure Pull/Push(DCSG01061674 (Port Of Defect DCSG01074900) Fix LSA time sync problem(DCSG01029543 (Port Of Defect DCSG01034066) PCIE failure causes TBM failure which leads to control plane hang(DCSG00969750 (Port Of Defect DCSG00990809) Incorrect usage of Block Limits Virtual physical disk npwg field resulting in 0x7 being treated as 7 512B sector length IOs with NVMe drives(DCSG01026871 (Port Of Defect DCSG01032306) Assertion failure in FW when user initiate rebuild on partial degraded R6 VD(DCSG00921397 (Port Of Defect DCSG00970530) Fault 0xEC0F seen while aborting an active recovery on a NVMe drive(DCSG01021656 (Port Of Defect DCSG01023749) FW stuck in COL-BIOS Reset loop when COL times out(DCSG00907382 (Port Of Defect DCSG00932410) MR7.20-Discrete part iMR controller allows PSOC flashing(DCSG01066232 (Port Of Defect DCSG01070280) CLI application shows improper error import message after successful Foreign import(DCSG00915940 (Port Of Defect DCSG00970535) MR7.20-Drive pull during recon-Assertion failure in fw\raid\pd.c at line 8254 AR Invalid(DCSG01054517 (Port Of Defect DCSG01066945) Kill adapter seen on multiple EPDs with IOs with TMs(DCSG00923995 (Port Of Defect DCSG00970534) Controller marks a drive UBUnsp if the server is rebooted while running Sanitize Overwrite(DCSG01141274 (Port Of Defect DCSG01165082) Clearing the tty history with cli delete termlog command causes firmware to hang(DCSG01098208 (Port Of Defect DCSG01108301) EnhancementRequests: Add Firmware Version 11 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01149460 Update ControllerInfo Structure with PartNumber - API Changes(DCSG01064529 ATA Passthrough handling of ATA commands(PIO DATA IN) obsolete in latest ATA specification for backward compatibility(DCSG00999763 Connector Order change for 9502-16e controller(DCSG00966344 Safestore: MegaRAID key management feature: temporary key escrow(DCSG00918486 Clean up include files(DCSG00977963 added new BST file for shenandoah(DCSG01108340 PEX89000: Single host MPT BST support on Veloce(DCSG01024714 Update XSDs with Proper Active High/Low Flags for GPIO_LED_GLOBAL_FAULT(DCSG01082422 Block Multi-LUN / Multi-Actuator : SAS Device only Report as Unsupported Device(DCSG00907506 Snapdump: Remove duplicate entry in additional battery statistics(DCSG00951438 Reorder Snapdump files for reliability(DCSG01008677 Add PSoC 6 FW to Catalog File(DCSG01107483 SAS phy port configuration of UBM connected phys based on UBM DFC Link width.(DCSG00927212 Add a tool for code coverage(DCSG01000074 Improve python handling during code coverage builds (MR)(DCSG01040296 PL SATL : Add SAT translation for the Concurrent Positioning Ranges VPD page(DCSG00927210 Add Firmware Version 9 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01136458 PEX89000:Use SDB to inject errors in Error Counter BST testcase(DCSG01079551 Create offload expected status field in NVSRAM(DCSG01098154 Remove the Standard IO Header from cache offload module(DCSG00985595 SRAM layout changes for code coverage(DCSG01026846 Release Automation: automate rebase operation for phase specific streams(DCSG00950531 UBM error handling improvements and debug statistics data collection(DCSG00903198 Add Firmware Version 6 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01126019 Update linker script file for mbed TLS component(DCSG00966563 Add code coverage configuration(DCSG01005808 Update SAS 3.5 FW summary release notes(DCSG00979878 Add Firmware Version 3 for PartNumber 29211 to PSoC Catalog Image(DCSG01116340 Add Firmware Versions 27 and 1 for PartNumbers 15987 and 25731 to PSoC Catalog Image(DCSG01166118 Remove old MCTP OEM-conditional code(DCSG01016044 Spell Checking Corrections Part 6(DCSG00963337 DRAM layout changes for code coverage(DCSG01010648 Add Interposer PSoC 6 FW to Catalog File(DCSG01121802 Dump code coverage counters for Ondemand Snapdump(DCSG01020724 Add Code Coverage infrastructure(DCSG00981200 Remove some whitespace from the config page firmware(DCSG00968465 Check in the build system's supporting function that can checks print statement consistency(DCSG00977490 Add Lmid/Smid local/host mem dump into SD(DCSG00289727 Add partial xml for 9502-16i Controller OCP form factor(DCSG00961958 Integrate SPILIB 2.0 into MR Firmware for Aero, Sea and Ventura(DCSG00040487 Release Automation: Assign release type when creating ROP(DCSG00941419 [Aero] Enable UBM detection logic on all connectors for OEM HBA with SEP_PRESENT GPIOs(DCSG00927207 Improve code coverage statement counting near prints(DCSG01031751 Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API(DCSG01065378 Add Vision sources to cpld_src(DCSG01082289 Add Firmware Version 7 for PartNumber 29211 to PSoC Catalog Image(DCSG01128627 [UBM] Add detection of SAS/SATA drive with UBM backplane supporting IFDET2# and PRSNT#(DCSG00945423 Add Firmware Version 5 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01123516 Add 9502-16e board Nvdata to Aero ROP(DCSG00966467 Update BinToRom for Multiple PSoC Images(DCSG01063758 Release Automation: Update scripts for FW Ph21(DCSG01008758 Reorder Snapdump data collection for reliability(DCSG00991989 Add NVDATA option to change DMA Activate FIS timeout value.(DCSG00952761 Update PSoC Bootloader Design in MR FW for PSoC 6(DCSG01107508 Snapdump Enhacement - SES Module(DCSG00952775 MR SAS Multipath Improvements(DCSG00956036 Update PSoC MR FW Downgrade Block MFI_STAT to be More Clear(DCSG01155856 Release Automation: Check for failure during baseline creation(DCSG00958012 Add Reboot logs for windows Cache Offload BST(DCSG01074472 PEX89000: Veloce Cosim Dev BST framework(DCSG01001901 Atlas2 BST ER: PCIE and SysDMA feature BST Evaluation for COSIM(DCSG01006212 Snapdump improvement - dump NVRAM key info(DCSG00951413 Support flash usage above 4 MB(DCSG01006737 Add OEM build action to SCONS(DCSG00996371 Remove SASPARSER binary from Release Order(DCSG00957868 Clean up inline functions(DCSG00984425 Add Firmware Version 10 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01136459 Add Firmware Version 12 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01159010 Add Firmware Version 8 for PartNumbers 29211 and 29651 to PSoC Catalog Image(DCSG01130658 FDE logging improvement: consolidate VKI_PRINTF(DCSG00904945 Dump code coverage counters on controller reset(DCSG01005809 Create adjusted code coverage reports(DCSG01050388 MegaAPI_PVT: Move VPD get DCMD from private to public API to Enable end user tools to read custom SN(DCSG00950711 Improve python handling during code coverage builds (fw_bld_tools)(DCSG01040300 Code Space Optimization(DCSG01017044 Atlas2 BST ER: Multi host flash boot: create synthetic hierarchy and basic EP and config traffic(DCSG01021605 PEX89000:Veloce Cosim Dev BST error counter testcase(DCSG01006209 secureSignBin: implement feature to download the public key during signing or with explicit arg(DCSG01035866 (DCSG01082488 Enhance out of order insertion feature to support R1 & R10(DCSG00903546 PL SATA : Read logpage 12 and 13 during SATA initialization to get features supported for NCQ encapsulation using FIS porting(DCSG00779724 Improve a print error message in traceTool.py(DCSG00945787 Move to the latest mbed_tls version which is 2.26.0(DCSG00966339 Remove allocation of PCIe devices when NVMe is disabled in NVDATA(DCSG01015478 PEX89000: Update Cosim DevBST framework to support launching simulation from outside user shadows(DCSG01093267 SPILIB2: Port all changes AV1 to AV2 for manual access files(DCSG00917802 Add PERC Signing Build Targets to fwSConstruct(DCSG01071385 Add Scons checking for code coverage(DCSG01026819 Support streaming of debug logs (HTB) via I2C OOB band on Ventura/Aero IOC/HBA (Part B)(DCSG00927213 LD Secure Erase and Progress Reporting(DCSG00931395 PEX89000: Update BST framework for Linux host and other enhancements(DCSG01062557 Add Atlas2 A0 devBST for automatic CQ launch(DCSG01003423 SPILIB: Update build scripts for ADS(DCSG00943761 Reintroduces the previous security page as MR_MPI26_CONFIG_PAGE_SECURITY_1 to align with current NVDATA(DCSG00977495 Extending SnapDump Persistence(DCSG00247000 (Port Of EnhancementRequest DCSG00966519) Enable DASEP detection on SASA for Adapters(DCSG00983302 (Port Of EnhancementRequest DCSG01071382) Bad Phy detection logic improvement(DCSG00932841 (Port Of EnhancementRequest DCSG00977228) Error handling of UBM CHANGE_DETECT# signal(DCSG00962565 (Port Of EnhancementRequest DCSG00963253) Do not generate "Bad Phy" event for NVMe drives that fail NVMe Init(DCSG00543046 (Port Of EnhancementRequest DCSG01070337) Update ControllerInfo Structure with PartNumber(DCSG01063757 (Port Of EnhancementRequest DCSG01074470) Disk labels need to be tied to fixed physical ports in order(DCSG00240927 (Port Of EnhancementRequest DCSG00966521) Enable DASEP detection on SASA for Adapters(DCSG00983302 (Port Of EnhancementRequest DCSG00990994) MR FW Need a smooth and authenticated method to transition from LKM to EKMS (SEKM)(DCSG00318546 (Port Of EnhancementRequest DCSG00432105) Passthrough Support for Vendor Specific NVMe Opcode D9h and C0h(DCSG01128891 (Port Of EnhancementRequest DCSG01151746) Create new profile with only SAS/SATA drive support for new controllers for DASEP backplanes(DCSG00991280 (Port Of EnhancementRequest DCSG01070765) Remove Retries When INQUIRY for Extended VPD Page 86h Returns 5/24/00(DCSG00922081 (Port Of EnhancementRequest DCSG00966515) NVMe Passthru command support(DCSG00432879 (Port Of EnhancementRequest DCSG00966518) Add PSoC Image Checking and MR FW Blocking(DCSG01064530 (Port Of EnhancementRequest DCSG01074471) Enhance Error scenario handling in SEKM Feature code(DCSG00966411 (Port Of EnhancementRequest DCSG00974796) Create new profile with only SAS/SATA drive support for new controllers for DASEP backplanes(DCSG00991280 (Port Of EnhancementRequest DCSG01069429) Update and Add PSoC Image Building Batch Files(DCSG01063756 (Port Of EnhancementRequest DCSG01074467) Do not generate "Bad Phy" event for NVMe drives that fail NVMe Init(DCSG00543046 (Port Of EnhancementRequest DCSG01070769) LKM compliance to Cryptographic Algorithm Requirements v1.5(DCSG00830702 (Port Of EnhancementRequest DCSG00966516) Sea iMR CBB Updates(DCSG00980247 (Port Of EnhancementRequest DCSG01032931) Version 52.19.0-4165 - Moderate Impact/Low Probability of Occurrence ------------------- BIOS:7.19.00.0 UEFI Driver:0x07130200 HII: 07.19.04.00 IMR FW: 5.190.01-3553 package 52.19.0-4165
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
ThinkSystem RAID and ServeRAID M Series SAS/SATA Controllers Driver for Linux Supported Kernesls: RHEL 9.0,9.1,9.2 Adapters Supported: ThinkSystem RAID 530-8i PCIe 12Gb Adapter (7Y37A01082) ThinkSystem RAID 530-4i Flex Adapter (7M17A03932) ThinkSystem RAID 530-4i Flex Adapter (7M27A03918) ThinkSystem RAID 530-8i Dense Adapter (SD530 RAID) ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727) ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter (7Y37A01083) ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter (4Y37A09722) ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (7Y37A01084) ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085) ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086) ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (7Y37A01087) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M17A03933) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M27A03917) ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721) ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728 ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735 NOTE TO SERVICE - Reference RETAIN #N/A 07.727.04.00- Moderate Impact/Low Probability of Occurrence -------------------- MR 7.27 EnhancementRequests: -RHEL9.3 GA OS support.(DCSG01598981) -RHEL8.9 GA OS support.(DCSG01616753) 07.727.03.00- Moderate Impact/Low Probability of Occurrence -------------------- MR 7.27 Defects: -OS support list file update.(DCSG01539093) -Fixed driver compilation for CONFIG_COMPAT.(DCSG01220245) -Kernel with no compat_ioctl support leads to compilation failure.(DCSG01237312) -IOs on un-intended virtual drive fails when a different virtual drive is pulled out.(DCSG01417063) -Linux Driver ReadMe Cleanup.(DCSG01536648) -irq_free call trace seen upon driver shutdown.(DCSG01531523) -oe20.03 LTS-SP1 driver binary RPM is missing from the latest RO.(DCSG01269925) -Remove RHEL 9.0 RT kernel binary.(DCSG01238725) EnhancementRequests: -RHEL8.7 GA OS Mainline kernel and RT kernel support.(DCSG01364506) -MR7.27: SLES15SP5 OS support.(DCSG01451936) -Added support for RHEL8.6 GA.(DCSG01215194) -SLES15 SP4: Update OS support list file.(DCSG01234735) -Created a Fusion OS 22_22.0.1 build kit to generate driver binaries.(DCSG01232277) -RHEL9.0 GA OS Mainline and RT kernel support.(DCSG01364140) -MR7.26: RHEL9.2 GA Mainline and RT kernel OS support.(DCSG01438455) -Add megaraid_sas driver support for Fusion OS 22_22.0.1.(DCSG01324301) -SLES15SP4 GM OS RT kernel support (Build kit support).(DCSG01365053) -MR7.26: RHEL8.8 GA OS mainline and RT kernel support.(DCSG01438447) -Added Capability Bit for Driver Dump Mode Status to MFI_CAPABILITIES.(DCSG01321222) -RHEL9.1 GA OS Mainline kernel and RT kernel support.(DCSG01364319) -SLES15SP4 GM OS RT kernel support.(DCSG01365021) 07.722.02.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.22 Defects: -Megaraid 7.22: RHEL 9.0 has RT kernel binary, as per PR support on 7.23 onwards..(DCSG01238725) Enhancements: -SLES15 SP4 OS driver support.(DCSG01132146) 07.720.05.00 - Moderate Impact/Low Probability of Occurrence -------------------- Initila Release
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
LSI Storage Authority Software Supported controllers: ThinkSystem RAID 530-8i PCIe 12Gb Adapter (7Y37A01082) ThinkSystem RAID 530-4i Flex Adapter (7M17A03932) ThinkSystem RAID 530-4i Flex Adapter (7M27A03918) ThinkSystem RAID 530-8i Dense Adapter (SD530 RAID) ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727) ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728 ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735 ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter (7Y37A01083) ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter (4Y37A09722) ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (7Y37A01084) ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085) ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086) ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (7Y37A01087) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M17A03933) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M27A03917) ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721) ServeRAID M1210 SAS/SATA Controller (00JY194) ServeRAID M1215 SAS/SATA Controller (46C9114) LSI SAS3004 RAID (NA-SAS3004-B) LSI SAS3004 RAID (NA-SAS3004-N) ServeRAID M5210 SAS/SATA Controller (46C9110) ServeRAID M5225-2GB SAS/SATA Controller(00AE938) ServeRAID M5215 with 2GB Flash Enablement Flex System x240 M5 (00JX142) ServeRAID M5210e SAS/SATA Controller (46C9117CTO) ThinkSystem 430-8i SAS/SATA 12Gb HBA (7Y37A01088) ThinkSystem 430-16i SAS/SATA 12Gb HBA (7Y37A01089) ThinkSystem 430-8e SAS/SATA 12Gb HBA (7Y37A01090) ThinkSystem 430-16e SAS/SATA 12Gb HBA (7Y37A01091) ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA (NA-StarkSASHBA) ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA for 4Y37A09724 ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA for 4Y37A09725 N2215 SAS/SATA HBA (47C8675) N2225 SAS/SATA HBA (00AE912) N2226 SAS/SATA HBA (00AE916) Supported Operating Systems: OS supported =Windows 16,windows 2019 008.007.011.000 - Moderate Impact --------------- MR 7.27 Defects: LSAServer: Update toolchain (RC) for LWA and LWM ESXi builds(DCSG01320042 In the latest LSA, source drive information is missing in the Replace drive progress bar(DCSG01364273 user will not be allowed to schedule PR in absence of virtual drive if max concurrent driveis set to 0 and increased incrementally(DCSG01314003 While setting link speed, LSA throw SCSI related error.(DCSG01458284 Sorting based on RPM is not working properly(DCSG01494370 physical sector size 0B observed in Lun information instead of 0KiB when pull/push performed on a drive in sanitize.(DCSG01450014 LSA Common: Resolving Merge conflicts from 8.3 > 8.0 Int(DCSG01262331 7.25/8.5: syslog events for LSA_MONITOR shows The message resource is present but the message was not found in the message table for enclosure pull push events(DCSG01368817 When change types of PSOC is same, force option displays wrong message(DCSG01317226 UI issues pertaining to mail server tab(DCSG01266601 WG_8.3: LSA Doesn't launches in presence of 240 Virtual Drives & JBOD's(DCSG01271180 In server profile page, Virtual Drive information shows blank(DCSG01235335 On enabling security key, Security key identifier field shows blank(DCSG01388013 Unable to display enclosure information in server profile page.(DCSG01261504 WG: Advanced configuration page does not provide creation option with "Enable Unmap/Write Same Unmap" on selecting raid level "compare and select" after selecting span raid levels(DCSG01266690 DevicePersistentID values matches with catalog file shows wrong values(DCSG01513916 "Invalid_Port_Number" message is displayed for a valid port.(DCSG01412809 LSA 8.5 PA: LSA lists unsupported ASO options (RAID 5/50 & RAID 6/60) on EVP controller(DCSG01401720 Faulty enclosures are not listing with need attention message in View server profile page(DCSG01398647 Not allowed to start PR on DHSP once initiated patrol read is stopped and tried to schedule again(DCSG01391056 Sorting based on RPM is not working properly(DCSG01350732 Issues pertaining to change security key when Empty security key identifier is provided(DCSG01409016 Fixed: upon reboot permissions are not setup for daemon to start(DCSG01253838 PH27 SL Update copyright info with Storelib header files(DCSG01416456 Auto configure behavior (Execute Once) fails with Error Code: 69637(DCSG01536197 SLP daemon not started..discovery issues seen on Open Euler(DCSG01267736 After Reprovision of Secured Drive, Autoconfig behavior(execute once) option is not available.(DCSG01244895 Not able to create Virtual Drive with latest LSA(DCSG01377640 7.25/8.5: empty SAS address is shown for post LSA install syslog events(range of events: since last shutdown)(DCSG01384579 8.4: Change Auto configure behavior options does not load if user tries to disable Security with Auto configure behavior (Primary) set to Secure Single Drive RAID 0(DCSG01343890 Povides option to upgrade firmware in presence of pinned cache, on trying to flash fails with incorrect error message(DCSG01391192 WG: 7.24: LSA back end response fails with 500 ok even if PSOC is upgraded successfully with GUI notifying "Please shutdown the system for the changes to take effect"(DCSG01317234 Fixed: Populate Recording technology as per Schema(DCSG01267495 While in manage server page the LSA provides option to go to setting page, blank page loads for mail server settings.(DCSG01459844 Hard Disk Drive RPM shows "An user is already Logged in with Different Credentials" instead of showing actual values(DCSG01370701 : unable to create Virtual drives less than 1 MB capacity on , CLI allows(DCSG01493566 Duplicate 0x8163 entries in slerrors.h(DCSG01416228 Issue related to "Elements Actions" tab for JBOD drives.(DCSG01338700 Fixed: ram space getting filled due to lighttpd logs(DCSG01503349 Transformation progress bar is showing even after deleting the Virtual Drive(DCSG01267235 Issues pertaining to Physical Drive Tab When Online capacity expansion is in Progress(DCSG01396408 Fixed: Unable to create mix of NVMe and RUBY NVMe Raid 0 in LSA(DCSG01372764 vlolume capacity value incremented is equal to number of times the units are switched(DCSG01545756 Fixed: Health status for Unconfigured Bad drives are shown as optimal instead of need attention(DCSG01446521 Add Virtual drive option is enabled even though volume count field is empty while adding volume on hole.(DCSG01458772 LSA references need to be removed from readme file(DCSG01259514 Select all the drives from list in controller console page and then clearing the filter, select all element count does not reset to 0(DCSG01267749 LSA 8.3/7.23: On ESXi 8.0 OS, lsa services shows blank(DCSG01267632 Fixed: adding extra stripe only for full virtual drive resolves the issue(DCSG01515337 LSA v8.006.003 greyed out secure Volume configuration on M7 1U(DCSG01457669 unable to create R1/R5/R6/R50/R60 Un map Volume(DCSG01389335 Pop up warning is not listed when more than 32 drives are selected and list is expanded.(DCSG01405727 7.24: Force option for downgrading /same psoc flashing should have proper message(DCSG01302650 Resume/Suspend Rebuild of multiple Physical Drives from element actions is throwing error.(DCSG01251335 WG: 7.23 :LSA does not allow to add autodiscovered/manually added VMware server to manage server list in Manage server page(DCSG01262411 Changes in Viewlist option panel(DCSG01538044 Security Drive properties are not shown under physical drive properties for HUC109030CSS61E model drives(DCSG01404857 LSA: SAS4X expander series temperature values showing incorrect in LSA when comparing with storcli and ses page output(DCSG01396986 Firmware upgrade error message needs update.(DCSG01380171 8.6 LSA : Need attention message is not getting updated properly if doing enclosure push/pull & though drives are getting updated properly in drives tab(DCSG01444354 "Add volume drive" button is disabled during Volume creation.(DCSG01319015 Fixed: Localization skipped due to legacy URL(DCSG01255290 fixed: minimum size check added before virtual drive creation(DCSG01445777 LSA fails display foreign config as non importable foreign config.(DCSG01496355 LSA 7.25/8.5: RWC3 is not getting launched in Ubuntu 22.04 OS(DCSG01390390 Issue pertaining to Compatible warning(DCSG01323709 LSA 7.24: LSA is showing missing 0 for all the missing Physical drive position in Foreign configuration page(DCSG01343227 LSA8.5: Windows installer showing older version(DCSG01387006 After clearing Foreign configuration, Autoconfig execute once option is available only after LSA service restart(DCSG01414090 Slot details are missing during replace missing operation.(DCSG01537534 When hot plug performed on a drive while spin up is in progress, invalid error code and empty description is seen.(DCSG01499881 Fixed:LSA lists secure Physical Devices during simple configuration.(DCSG01521491 Kib option needs to displayed during volume edit also and when unit is changed up and downbutton click are not working(DCSG01493365 LSAServer: Exception handling for datatype mismatch(DCSG01528882 Configuring 'Auto configure behavior (Execute Once)' fails with Error Code: 69637: Operation is either not allowed or not supported(DCSG01385774 LSA shows Additional Info as Invalid when firmware returns MR8_DCMD_STAT_OK_WITH_INFO(DCSG01537992 Update LSA readme with Redistributable details(DCSG01523941 Download events option is coming unnecessarily when there is no event in event log section(DCSG01358957 Fixed: Build Environment error(DCSG01401230 "load factory defaults" button is greyed out during "maxconcurrency" field update.(DCSG01380169 LSA doesnot show information about Number of Physical drives selected for Spinup(DCSG01388125 Snap5_PA5 : Capacity unit for drives shows TiB/GiB instead of TB/GB in HSW(DCSG01255102 LSA asks for user confirmation for making a Physical drive online in Controller health.(DCSG01380094 Once the Raid 6/5/60 un map created, even in presence of SDR0 un map capable drive, un map option not shown for SDR0 volume creation.(DCSG01388417 8.5/7.25: LWA / LWM ReadMe needs update(DCSG01404426 During Foreground initialisation in progress, Modify Properties option available when multiple V_Ds are selected(DCSG01404960 8.7/7.27: empty IP address listed in view server profile for LWA : VMware 8.x(DCSG01511887 WG:8.4:Secured UG un map drives are listed during non secure Advanced Volume creation: UI, selecting and unselecting secure check box lists only secure drives in drive list of normal Volume creation(DCSG01325037 LSA 7.26/8.6: Corresponding OS support for gcc needs update(DCSG01453817 Physical sector size shows wrongly when user clicks NS/LU count in LSA, however old LSA version shows it correctly(DCSG01453954 Write Same Un map property is set to yes is observed for Un map Single drive raid 0 capable drive .(DCSG01321090 7.22_LSA: icon displays in red color instead of yellow color when the is in degraded state(DCSG01253166 LWA 8.5: Error code/description is not showing when snapdump is generated more than once(DCSG01414058 DevicePersistentID value is 1 even after changing(DCSG01513969 Reporting order details in factory defaults and merge conflicts in panel(DCSG01514059 LSA Server: Resolving Merge conflicts from 8.3 > 8.0 Int(DCSG01260379 "Make Good" option is not coming for Ubad drive in controller main page, however that option is coming in server landing page or if user selects that Physical drive(DCSG01373824 8.7/7.27: VMware esxi 8.x/7.x LWA/LWM readme needs update(DCSG01546872 read me changes: 8.2 read me changes has not been ported into 8.3(DCSG01262717 LSA asks for system restart on reinstalling LSA using Repair option(DCSG01537984 LSA Server: Cosmetic issue at controller serial number display(DCSG01313735 Warning message need to be revised when moving Physical drive from Failed state to Online.(DCSG01436659 When schedular wrapper is enabled, Needs manual refresh for multiple drives operations to get updated(DCSG01417288 Rebuild background operation disappears, when any other drive completes cryptographic erase(DCSG01397012 When drives is removed during online Capacity Expansion, LSA doesn't display proper drives details.(DCSG01452727 Fixed: Update Preview based on lock key create and destroy(DCSG01448439 Enable Un map/Write Same Un map check box selected during advanced Volume creation does not reset on changing raid level from "Compare and select"(DCSG01313852 Current & default values are displayed same value as server(DCSG01536651 Fixed: Added check for max configurable drive group in configuration service(DCSG01521934 Physical drive details of few of the enclosures are not listed in other hardware tab of 240 Physical drive configuration ( 6 enclosure : 45 Drive in each enclosure)(DCSG01239121 LSA 8.7: LSA shows First Device Persistent ID default value as 65535 whereas storcli shows None(DCSG01538244 8.4 LSA : NS/LU Count ascending or descending order is not working in Other Hardware tab, however it works in Drives tab(DCSG01340701 LSA: Type of enclosure is displayed as SGPIO instead of SAS Expander and serial number of enclosure is displayed as N/A on enumerating physical drive properties.(DCSG01516885 Chip Temperature in volatile properties shows 0c(DCSG01396163 WG_85: In PR Start now check box by default enabled even after unselecting Volume(DCSG01388577 7.26 Windows MRSA Compilation issue(DCSG01472716 In case of multiple logical drives, LSA is not list all of them(DCSG01542398 temperature shown as 255c(491 F) for drive in prepare for removal state(DCSG01384735 Fixed the typo in group name(DCSG01403741 LSA 8.7: First Device Persistent Id is not listed in modified factorydefault properties whereas it is listed in the storcli(DCSG01533194 8.4 LSA: Unwanted message is getting displayed though user is typing correct percentage value in "Set Adjustable task rate"(DCSG01358952 Sorting is not working for Physical drives in Unconfigure good(Sanitize) state.(DCSG01376947 LSA crashes during "Element actions" expansion on selected drives.(DCSG01429902 Issues related to error code for Disable Unmap/write same Unmap and factory defaults operations(DCSG01467221 LSA crashes observed on windows OS(DCSG01387247 WG_8.3: Multiselect V_Ds combination of BGI operation in progress and suspend state shows incorrect V_D operation(DCSG01252032 Fixed: Updated lighttpd to run in foreground mode(DCSG01509763 Error code 10 invalid parameter:invalid strip size seen when Raid 6 is created using FDE SSDs(DCSG01505932 Fixed: On EVP controller, LSA lists unsupported advanced software options(DCSG01391906 WG: 8.5: ESXi 8x port number details are missing in readme(DCSG01388368 LSA 8.7: In the list of modified factory default properties for device reporting order shows Boolean values instead of property details(DCSG01526556 WG: 8.4 Schedule PR/consitency checkpage does not allow to increment schedule interval using arrow icons, allows user to configure schedule interval above max limit and fails.(DCSG01340847 debug level not proper in windowsSystem file(DCSG01524861 Pop up message is not displayed under Drive Tab on selecting max Drives(DCSG01263719 Latest LSA shows Redhat symbol for SLES15SP4 OS(DCSG01524378 LWA 8.4: OLH is available for all the options, Upon clicking on OLH, '404 Not found' seen.(DCSG01322295 LSA 8.4 does not repair failed NVMe drive due to namespace(DCSG01329197 LSA 8.5: Progress bar for PhysicalDisk Clear/Sanitize updates only after manual refresh(DCSG01371448 LSA Release: Resolving Merge conflicts from 8.3 > 8.0 Int(DCSG01262930 On giving invalid maximum Volume range & select spinner up/down button shows notification at the bottom of the page(DCSG01321795 LSA shows 'No Controller Found' on page refresh while OFU is in progress whereas storcli says controller is in reset state(DCSG01531144 LWM_ESXi and RWC3 Readme Update(DCSG01547916 LSA allow add config option in case bad drives present in the system(DCSG01395097 Slot Status is not displayed for bad NVMe drives under other hardware tab where as storcli2 displays proper data(DCSG01405220 LSA Common: Update Single 3rdPartyComponent file changes to ARM StandAlone script(DCSG01331356 LSA Server: UnSupported Drive Health Status is not reflecting(DCSG01268098 Clear events option/button is not coming(DCSG01340707 WG: 8.4 : EVP : LSA provides option to create Advanced and Simple configuration with hotspare(DCSG01312261 Less than max drives get selected if user toggle around the checkboxes of drives table(DCSG01422162 NVDATA version is not reported in controller detailed info(DCSG01383626 In absence of spin down drives, when user tries to spin up/start drives, no notification shown on non eligible drives(DCSG01387209 LSA does not ask for user confirmation for making a Physical drive from the server landing page.(DCSG01373614 LSA 8.7: JBOD's are not listed in the View list of Device Reporting Order page on IT controller however it allows to set.(DCSG01544915 UI Issue in Manage PCIE Lane speed page(DCSG01485557 WG: 8.3: duplicate files in gen 7 & 8 corpus folders are generated on server report download(DCSG01245896 Dual actuator drive: SED type is not displayed properly for OPAL multilun drive(DCSG01388189 LSA 8.6: LSA shows error and failed to move the SSD Unmap capable bad drive to Good state(DCSG01437987 source drive information is missing in the Replace drive progress bar(DCSG01371447 LWA server is taking too long to respond page shows empty suggestions field & also suggestions icon missing(DCSG01408592 Fixed: Add Virtual drive to fill the configurable free space(DCSG01390558 Exception handling and non initialized variable in plugin manager code(DCSG01527510 "Select and unselect " operation results in pop up message issue.(DCSG01232138 7.25: Pending profile in Profile Management does not get updated in LSA after changing the controller profile(DCSG01399792 Un map Raid 60 Volume creation allows to add the same Drive twice(DCSG01379532 rpm commad is seen in ubuntu service script(DCSG01486111 LSA 8.7: Multiple pop up messages & error code 0 is observed on changing device reporting order.(DCSG01510565 8.5 LSA : Snapdump trigger time is not showing (for Firmware trigger type) in LSA as it is showing blank, however Storcli shows time properly(DCSG01371510 LSA Common: Resolving Merge conflicts from 8.3 > 8.0 Int(DCSG01269998 single drive under OC_E tab seen when 3 drives are added for expand operation(DCSG01422299 Lun Physical sector size property unit is displayed as 0B instead of 0KiB(DCSG01451693 LSA 8_4: Client issue WRT consistency check /Patrol read scheduling.(DCSG01312223 Unwanted message is getting displayed when user deselects more than 32 drives in enclosure(DCSG01356381 0LH issues pertaining to Replace Missing Drive & Personality management. Refer Screenshots.(DCSG01437047 While Replace drive is in progress, LSA allows for Virtual Disk expansion.(DCSG01258831 LWA ESXi8: LWA hungs in Firmware File Upload in progress page while Updating firmware(DCSG01518941 sorting after filtering of SATA drives in drives tab of Drive group with mix of SAS and SAS drives populates empty rows(DCSG01390097 Fixed: display error text for corresponding err code 20(DCSG01255146 8.5 LSA : Physical sector size shows as 512B in LSA & 0KiB in Storcli for Unconfigured bad drives(DCSG01370635 Transformation Rate is allowed to configure, operation fails with error: 'Description: The requested command has invalid arguments.'(DCSG01525551 OLH integration for device reporting order(DCSG01555807 Issues pertaining to multilun drive details(DCSG01446395 LSA 7.25/8.5 : LWA is not launching in ESXi 7.0(DCSG01409492 Add volume to existing DG not consistent with new DG volume Size selection(DCSG01459130 In Gateway Authenticate page, on giving invalid credentials 'Error code' is missing(DCSG01395266 Issue regarding ASO page.(DCSG01266595 LSA 9500 Series 7.24: Downloaded events files does not show information about locale(DCSG01317982 Drive details are not displayed under DriveGroup tab in linux OS(DCSG01371143 Inbound Port Numbers used needs update in Esxi 8x readme(DCSG01510521 Drive capacity shows 272GB for 0KB drive and also logical sector size shows blank, however Storcli shows the info properly(DCSG01432818 Rescan is deactivated for incomplete foreign configuration(DCSG01464067 Prepare for Removal state Physical drives are shows under spin up action.(DCSG01388913 Multi Select issues on config file edition to large number(DCSG01249884 content validation issues: Controllers Get and Configuration service Get JSON(DCSG01327552 LSA crashes on clicking configure in presence of offline raid 5 Drive Group(DCSG01256843 Drive list continuously reloads for more than a minute on after discovery of all drives post enclosure powerup(DCSG01467320 Invalid 4096blocks are displayed under free and configured space in drive group json file.(DCSG01403686 gcc version to package mapping incorrect in latest LSA & LWM Linux readMe(DCSG01525609 Rebuild background operation disappears, when any other Physical drive completes cryptographic erase(DCSG01315005 Fixed: select all in adv configuration when all drives are in one group(DCSG01259350 after 'enabling/disabling Unmap/Write Same' on unmap Virtual Drive , Controller status and health is not updated.(DCSG01267218 LSA 8.6: Issues related to drive properties JSON(DCSG01437692 LSA Common: Restore Sensitive data during upgrade(DCSG01300773 Enclosure properties are not listing(DCSG01335728 WG: 7.24 :LSA controller header does not get updated on changing to 'None' mode from any of 'JBOD' or 'Raid 0" mode(DCSG01340931 LSA 7.24: "Make Failed" option is not working in Controller console page.(DCSG01333222 User notification in presence of incomplete foreign config shows as 'incompleteforeig'(DCSG01324264 LWM ESXi 8.3: Events are not seen in syslogs and no EMAIL notiification for events in LWM ESXi.(DCSG01259520 Max PCIe drives & Max V_Ds under controller profile properties shows that "Max user count reached" instead of actual count in LSA(DCSG01534631 LWA signing validation : Fix Permssion errors(DCSG01544474 controller, advanced software options shows Location has 'UNKNOWN' & other Error code issues(DCSG01524476 Number of slots for PCIe switch is showing UNKNOWN in LSA whereas storcli shows 8(DCSG01403936 Decimal Value is accepted & > Sanitize Drive option is enabled when Overwrite Count value is blank > Start Sanitize option(DCSG01254763 Minor memory leak issue in LSA(DCSG01540372 No success or failure notification shown after SpinUp of Power Save drives(DCSG01511987 even after discarding preserved cache, LSA controller console page does not provide with firmeware update link until manual refresh(DCSG01422163 Fixed: Adding populated bit check resolves spindown invalid value issue(DCSG01544914 8.7: controller health status does not get updated until manual refresh on changing device reporting order(DCSG01537772 "Sanitize Drive" option is greyed out when user removed the overwrite count and increased/decreased the count using up/down button(DCSG01266004 WG_8.4: net::ERR_ABORTED 404 (Not Found) & uncaught ReferenceError: $ is not defined are observed in developer console on accessing LSA(DCSG01313757 shbiradaLSA 7.24: Warning symbol is showed for Failed PSoC Image flash(DCSG01317224 Lun info is not populated in case of one lun is unusable.(DCSG01458171 Controller Name missing from the drop down of MRSA(DCSG01359052 changed: updated constant and removed extra space(DCSG01493178 LSA 7.x: Issues related to drive advanced properties.(DCSG01314720 Secured Locked drives are not shown as Foreign Drives(DCSG01234843 Physical drive tab filter operation issues during online capacity expansion(DCSG01493437 Fixed: set max limit of DG with provided max arrays and max logical drives(DCSG01540470 Physical sector size and Logical sector size unit shows 0B instead of 0KiB for Bad unsupported drive(DCSG01410531 1024 KiB is volume is created as 1 GiB, 1 TiB volume is created instead of 1024 Kib on modifying volume during volume creation(DCSG01507403 unlocking secure foreign configuration is not getting imported in LSA(DCSG01461999 LSA 7.23/8.3: Readme updation(DCSG01258231 Number of available unconfigured SSD drive shows as "0" always for SSD volume , however number of available unconfigured drive count shows properly for normal(DCSG01462172 WG_8.4/7.24: In the latest LSA, the select controller drop down does not list all the controllers present in the server(DCSG01335045 Incorrect uri for phy response and incorrect physicalDeviceCount is seen in json file of Virtual Drive properties(DCSG01260941 LSA_Server: Remove dynamically generated files from the source(DCSG01271245 Sanitize Drive option is disabled when cryptographic erase is selected and emptied the overwrite count field.(DCSG01410838 Update Firmware option is available for user Login and issue related to Schedule consistency page.(DCSG01517376 Write Same un map option is active in presence of secure & Un map SDR0 capable drive(DCSG01311031 Error observed on changing the behavior mode with pending personality change(DCSG01400686 Partner enclosure details are listed "twice" and sometimes the details are "missing" for multipath connection.(DCSG01391728 hanging security key is successful on giving invalid current security key(DCSG01380232 Firmware Update needs manual refresh(DCSG01506798 Adjustable task rate reset issue and Issue observed device persistent ID not set(DCSG01526787 after unlock a secured drive has different secured key, the import is successful, but clear button is still enabled(DCSG01545365 Volume is getting created more than the user mentioned Volume size in LSA & Volume is getting created in KB(DCSG01554067 Multiple calls are fired for all controller operations after Deleting Volume.(DCSG01396386 Current file field and Updating file field are not matching in the PSOC firmware update window(DCSG01357017 Copy into fixed size buffer issue in plugin(DCSG01518270 Update the readme with support OS matrix for 8.7/7.27(DCSG01567410 Issues pertaining to Advanced Software options activation key error(DCSG01364779 WebGUIRelease_8_3 : Unmap drive volume for replace drive does not work from LSA, storcli shows success and operation is successful. Disable SCSI unmap action success message needs rewording.(DCSG01264762 8.5 LSA: Logical sector size shows blank in 8.5 LSA for a drive(DCSG01370670 Logical sector 4KiB seen instead of 512B in the filters of Add Phyiscal Drive table of expand operation on SSD volume or add hotspare for an HDD 512 B volume(DCSG01420958 8.3_LSA: Modify Virtual drive option shows "Always Write Back" option for CC(DCSG01262398 Populated Settings are not mapped to drive types(DCSG01494684 WG: 8.4 :entering out of range max virtual drive in schedule consistency page and then saving results in Invalid URI Parameter/Invalid parameter 0x0 respectively(DCSG01340864 LSA 7.25: No option to make the drive in failed state to offline/online from controller health and Server Summary page.(DCSG01399833 LWA client packaging script changes(DCSG01543821 On manually entering more than max limit schedule time & increasing & decreasing it using spinner will not allow set schedule Consistency Check & PR(DCSG01396368 Creating 240 Drive Groups using auto configure execute now option. deleting one Drive Group and creating one Drive Group again, LSA Crashes(DCSG01252684 Un map option shown for R5 in presence of one SDRO Un map& 2 Un mapcapable drives also Volume creation is sucessful but No Volume created(DCSG01375654 LSA notifies user to clear foreign configuration instead of requesting user to wait for availability of persistent IDs(DCSG01314944 In Lun information, Physical Sector size for drive is showing as 512B instead of 4KiB(DCSG01500047 Inconsistencies between the apps in factory defaults(DCSG01533400 Code: 10 with Invalid parameter 0x0 is observed on giving Max volume more than 64 & then increase schedule hourly & save(DCSG01326147 Readme needs update in LSA_Linux_aarch64 RO(DCSG01472341 8.5: user allowed to select more than 32 drives in Start/Spin Up Drives page(DCSG01388638 selecting more than 32 drives, user not allowed to spinup drives until manually unselected to make selected drive count <=32(DCSG01422137 only self server getting discovered with v008.004.001.000 Linux Gateway(DCSG01313730 URI GET exceptions are observed in developer console on loading LSA page(DCSG01385606 8.4 LSA: Volatile properties field is not coming for Integrated 7. x controller, however, it comes for Megaraid 7. x, Megaraid Inv_ader, Megaraid Ven_tura, and Integrated 8. x controllers(DCSG01343290 Multiple Enclosure calls are made on click of view server profile when logical enclosure is connected(DCSG01249112 "Simple configuration" option provided when there are no drives to configure.(DCSG01429195 8.5 LSA : Snapdump trigger time shows blank (for Firmware trigger type if date & hour is 00) in LSA, however Storcli shows date & time properly(DCSG01410447 Discrepancy in Capacity of the virtual drive after expansion on changing percentage of available capacity in Expand virtual drive page(DCSG01401191 LSA 8.5/7.25: Copyrights need to be updated.(DCSG01392501 8.7/7.27 : LWA : Allowed to login as admin with empty password(DCSG01504973 Fixed: changed namespace addressing(DCSG01387208 Multiple offline Physical drives are made online without the confirmation of the action(DCSG01388097 8.3:LSA: With Standalone Installation, Events fails to load and other operations fails to get updated like virtual drive creation under DG tab, JBOD to UGOOD(DCSG01231626 Partial FC imported observed in presence of foreign locked SDR0 foreign configurations(DCSG01466726 View server profile is not showing any Vses/SGPIO details under "Logical Enclosure information"(DCSG01373713 LSA 7.23: Inconsistency in naming convention for replace drive events.(DCSG01267734 Storcli shows that Cryptographic Erase Capable as "No", but LSA shows Cryptographic Erase option for the same Physical Disk & it fails too if Cryptographic Erase option selected in LSA(DCSG01536041 Change the controller property name "Security is enabled." to "Security enabled."(DCSG01523523 Enclosure information is not coming in view server profile, however it is working fine in previous LSA build(DCSG01401229 Unable to download snapdump(DCSG01378013 Snapdump "save" button is shown as "enabled" instead of "disable"(DCSG01385988 server code compilation issue(DCSG01265860 Error code handling issue in LSA(DCSG01372037 LSA was time out for large setup(DCSG01235334 Drive capacity is shown as 0B instead of 0KiB(DCSG01389149 Context help missing for modify Virtual Drive Settings in Advanced Configuration Window under Virtual Drives section.(DCSG01236507 Issues pertaining to Snapdump properties and Update firmware.(DCSG01407964 Size warning & voulme Count issues in Add Virtual Drive page(DCSG01521755 Rhel 9 issue when system doesn't have driver and controller installed(DCSG01372966 8.7: faulty logical enclosure is shown is optimal(DCSG01534653 Invalid error message is shown on updating wrong firmware on AV controller whereas storcli shows properly(DCSG01444359 RPM field is empty while adding drive for virtual drive creation(DCSG01320875 WG: 8.3 LSA crashes on clicking controller more actions (Large Configuration)(DCSG01236595 8.5_LSA : Type 1 PI capable drives are not showing proper info as "protection Information" field says "Incapable", however Type 2 drive shows the info properly(DCSG01424988 Drive details are not listing for 9600 16e controller.(DCSG01405202 LSA fails Patrol Read scheduling when transformation is in progress.(DCSG01321091 "View all" button is greyed out in "factory defaults" page.(DCSG01402828 Secured UG unmap drives are listed during non secure Advanced Volume creation, operation fails(DCSG01315831 Patrol read scheduling inconsistency between storcli and LSA(DCSG01366824 Element action is set to zero when 2nd D_G's Physical Drive is selected.(DCSG01261361 GUI issues observed in Make secure jbod & schedule PR pages(DCSG01391925 LSA crash observed after clicking on Drive group(DCSG01459688 Fixed issue with memory limitation(DCSG01399007 LSA 8.7:LSA is encountering 50x page on making a drive offline on the ARM Ubuntu system(DCSG01518904 Logical sector size shows different values in different pages of LSA i.e. Drive tab shows 512B & View server profile shows 512KB(DCSG01419281 Unable to add/remove drives while performing RLM(R5 to R0) on a DG which has drive in failed state.(DCSG01436358 While Rebuild is in progress, Loading More Data message is shown instead of drive details(DCSG01358196 'unmap' option not shown at time of volume creation in presence of SDR0 unmap capable drive.(DCSG01369304 message when import config with more than 240 volumes support(DCSG01417277 No download in progress spinner shown for snapdump download resulting in multiple clicks & multiple snapdump file downloads & GUI issue in Enable security for eHBA controller(DCSG01318027 8.4 LSA: Sanitize drive option is getting greyed out when user selects Cryptographic erase option(DCSG01358970 reload option missing from both controller page and SS page. it appears as a flicker on page refresh and vanishes(DCSG01448035 Uninitialized scalar variable fix in the plugin(DCSG01517699 Other tab is showing extra count when compared to actuals for 730 8i card(DCSG01262397 Fixed:LSA ML drive LUN property not loading(DCSG01390115 Issue pertaining to Online capacity expansion by percentage(DCSG01436684 7.25/8.5: URI issues: Batch call for alarm fired even in absence of alarm, Controller Get and Virtual Drive get(DCSG01379940 "0 TiB" is listed during volume creation when the available free space is in MIB.(DCSG01400784 LSA: Cosmetic alignment issues in LSA needs to be adjusted(DCSG01388639 SED capable field shows Yes, but unsupported for SED drive, However Storcli shows correct values(DCSG01417548 Unmap volume creation is failing with Stripe Size 256Kib(DCSG01228715 Size of Vib installed more than 50 MiB(DCSG01503090 Next Learn cycle for Energy pack shows the year only 98 & it needs to be modified as its look like 1998 instead of 2098(DCSG01351108 LSA 8.7: ViewList in the device reporting order page does not show VirtualDrive's list present but allows to set any Virtual Drive ID(DCSG01532253 Unable to perform sorting operation for make jbod secure option.(DCSG01431188 LSA Common: Update standalone script(DCSG01310898 Replace missing drive fails with an error code 9(DCSG01391867 Page up option is not available in view server profile(DCSG01429230 In manage PCIE storage lane speed >change lane speed there is no option 32 GT/s.(DCSG01538664 Missing position is not displaying When user make the Last P_D missing which is used for V_D creation(DCSG01472321 Readme file doesn't have SLES15 SP4 and ESXi 7.0U3d for EGS platforms(DCSG01257749 Transformation Rate is allowed to configure, operation fails with error: 'Description: The requested command has invalid arguments.'(DCSG01523977 URIS displays the controllers in Enclosure details while querying with direct attached NVMe drives.(DCSG01267454 Stale/unused folders to be removed in lwa/lwmesxi(DCSG01509765 Handling the mouse over icons(DCSG01267773 OCE progress display issue(DCSG01258351 8.4_LSA: "Undo prepare for removal" options not listed for HDD drives.(DCSG01330276 LSA show missing a drive from disk array ( 3 drives R5) after a drive pull out.(DCSG01388316 LSA hangs after clicking on Drive Group in Foreign configuration page.(DCSG01373007 8.4 LSA: Observing 8.3 Package version in 8.4 Windows Readme(DCSG01331168 While Drive replace is in progress, progress bar shows ID instead of enclosure ID for Target drive(DCSG01358083 Downloading Virtual Drive properties from non admin login to LSA shows error code 5059.(DCSG01251156 LSA fails to launch and error 404 Not Found seen on Ubuntu 22.04 OS when installed gateway from gcc 8.3x folder(DCSG01531630 Help (?) is available for Foreign configuration page in LWA(DCSG01267360 Remove the default IO Policy for 8.x virtual drive properties(DCSG01523524 Make Jbod secure under more action does not populate info on the Drives selected(DCSG01392749 LSA is not accessible when user perform virtual drive delete.(DCSG01538005 Uncaught exception fix in the plugin(DCSG01518316 LSA_Expander: LSA showing incorrect voltage sensor information for Expander ( Volts to mV conversion)(DCSG01377740 WG:LSA does not allow to configure interval of schedule CC page using increment/decrement arrows on switching between Schedule CC and PR pages, able to configure non numberic value(DCSG01226056 Issues related to Set Adjustable task rate(DCSG01370698 LSA 8.3: Issue pertaining to Selected Elements in Element Actions when OCE is in process.(DCSG01234157 Remove unsed ServerID as it is not used in code(DCSG01527650 On restore factory defaults, view All button is enabled while controller is still booting up.(DCSG01345575 Update the RWC3 read me files for 7.x(DCSG01286202 Issues pertaining to LWM/LSA installation on Rhel9 OS(DCSG01388010 Volume creation in KiB not allowed using arrow keys above GiB value (ie 932 KiB volume creation not allowed if available capacity is 931 GiB)(DCSG01542896 "Energy pack" related "action elements" listed in DG page.(DCSG01383684 LSA crashes when clicks on Download server report(DCSG01251186 WebGUIRelease_8_3: Disable SCSI unmap action successful message to be revised.(DCSG01237180 Able to move the Physical drive to online without force option in Element Actions tab and controller health whereas need force from Server landing page.(DCSG01391403 WG: 8.4 : user will not be allowed to schedule CC/PR after clearing the schedule interval and clicking on 'load factory' defaults(DCSG01321082 issue pertaining to update of replace progress operation & SSL/TLS setting on flipping 'legacy' mode mail server setting(DCSG01448445 Removed unwanted debug logs(DCSG01515168 Progress bar is showing incorrect percentage of progress after suspended then re login to LSA(DCSG01263193 Context help message stays there even when after moving the hand cursor away from the "Modify Virtual Drive" button Under(DCSG01264802 LWA: Update firmware fails in LWA(DCSG01527107 Fixed: due to small size of requested Virtual drive, configuration was not created(DCSG01531274 Personality icon mismatch and css issues(DCSG01318889 MegaRAID8.5: Clear inactive session from the eventHandler notification(DCSG01357229 8.5: EVP : Allowed to assign dedicated hotspare to existing DG operation fails with error 'feature is not enabled(DCSG01396292 No sorting options seen on the columns in the Download snap dump table(DCSG01369290 "Advanced configuration" button should be disabled when no configurable drives are present.(DCSG01331971 WebGUIRelease_8_3: Tool tip, 'Virtual Drive Settings' alignment issue and SCSI unmap message to be reviewed.(DCSG01255110 Drive capacity shows as 272GiB size for 0KiB drive, however Storcli shows the info properly(DCSG01455591 WG_8.3: No success or failure message shown on importing foreign config(DCSG01259652 8.5 LSA : Capacity of drive shows different values in different pages of LSA, however Storcli shows correct values(DCSG01411784 Drive capacity under sanitize operation is not updated after hot plug of the drive ,Needs manual refresh and scsi related issues(DCSG01542923 LSA allows to create more than 16VDs under one DG(DCSG01494759 Sorting drives in 'Physical Dives' tab of D_G while OCE is in progress lists the OCE drives(DCSG01257249 clearing configuration while Drive "Overwrite" sanitize is in progress, progress bar vanishes until next progress event( URI missing in operations?queryparam=2), GUI issue in sanitize window(DCSG01231914 (Port Of Defect DCSG01233178) LSA Installation is failing on RHEL 8.5(DCSG01424675 (Port Of Defect DCSG01440803) test email is successful to non auth login supported SMTP server with Secure with SSL/TLS enabled and SMTPS Protocol(DCSG01473839 (Port Of Defect DCSG01481502) Write Same un map option is active in presence of secure & Un map SDR0 capable drive(DCSG01311031 (Port Of Defect DCSG01312475) Avenger_8.2_LSA:After successful Factory defaults operation, LSA fails to update the page with proper details(DCSG01203277 (Port Of Defect DCSG01218557) Windows Installer: Show the Windows Installer/Un Installer log this text is trimmed/truncated in some Windows systems(DCSG01286009 (Port Of Defect DCSG01286199) Current & default values are displayed same value as server(DCSG01536651 (Port Of Defect DCSG01537565) LSA 8.4 Rhel 9.1 OS: LSA is not getting launched when installed from "rhel9" folder(DCSG01373074 (Port Of Defect DCSG01384328) LSA is not reporting the correct temp on Promise 4U SAS 24 12G BP and not seeing any sensors on CSE 847E1C R1K28(DCSG01204031 (Port Of Defect DCSG01216088) WG: 7.23 :LSA does not allow to add autodiscovered/manually added VMware server to manage server list in Manage server page(DCSG01262411 (Port Of Defect DCSG01262999) 8.5_LSA: LSA crashes during "Download server report"(DCSG01422176 (Port Of Defect DCSG01436739) Success/ Failure message shown in LSA after entering the passphrase(DCSG01280209 (Port Of Defect DCSG01280296) CC page not showing incompatibility warning symbol(DCSG01315477 (Port Of Defect DCSG01315490) OLH for modify array fails to open 404 not Found(DCSG01343842 (Port Of Defect DCSG01354116) while scheduling consistency check on encountering Error Code: 3 Description: The requested command has invalid arguments.(DCSG01455517 (Port Of Defect DCSG01455520) 7.22: reload operation fails with Status Code: 500 Internal Server Error in LWA(DCSG01211031 (Port Of Defect DCSG01215298) 7.25: Pending profile in Profile Management does not get updated in LSA after changing the controller profile(DCSG01399792 (Port Of Defect DCSG01402390) Physical device Volatile properties temperature always shows 0C(DCSG01328323 (Port Of Defect DCSG01339470) On ARM server, LSA fails to install on FIPS enabled RHEL 9.1 OS(DCSG01419879 (Port Of Defect DCSG01431552) Under physical drive properties, Location is displayed as unknown in enclosure properties(DCSG01206477 (Port Of Defect DCSG01237526) WebGUIRelease_8_3 : Unmap drive volume for replace drive does not work from LSA, storcli shows success and operation is successful. Disable SCSI unmap action success message needs rewording.(DCSG01264762 (Port Of Defect DCSG01265361) LSA 8.4 Rhel 9.1 OS: LSA is not getting launched when installed from "rhel9" folder(DCSG01373074 (Port Of Defect DCSG01377727) PI capable drives are not showing proper info as there is no "protection Information" field in LSA, however Storcli shows the drive as PI supported drive(DCSG01424984 (Port Of Defect DCSG01428215) Description for cryptographic erase is different when selected single against multiple drives(DCSG01473698 (Port Of Defect DCSG01478972) LSA 8.7: JBOD's are not listed in the View list of Device Reporting Order page on IT controller however it allows to set.(DCSG01544915 (Port Of Defect DCSG01549005) 7.22_LSA: icon displays in red color instead of yellow color when the is in degraded state(DCSG01253166 (Port Of Defect DCSG01260297) Server 8.2: Resolving the compilation issue(DCSG01236625 (Port Of Defect DCSG01236666) WebGUIRelease_8_3 : Unmap drive volume for replace drive does not work from LSA, storcli shows success and operation is successful. Disable SCSI unmap action success message needs rewording.(DCSG01264762 (Port Of Defect DCSG01265127) 8.3/7.23 : Drive status is shown empty for drive in cnfSheild state(DCSG01286767 (Port Of Defect DCSG01288310) Unable to create secured WS un map volume during Advance configuration pages.(DCSG01286046 (Port Of Defect DCSG01298894) Check Consistency in background progress should be displayed as "Consistency Check"(DCSG01453598 (Port Of Defect DCSG01453771) Single LSA is not discovering the 95xx series controller on ubuntu OS in ARM system(DCSG01205160 (Port Of Defect DCSG01221104) 8.4 LSA : Volatile properties is not showing any values in LSA For drives(DCSG01368399 (Port Of Defect DCSG01388269) Firmware upgrade error message needs update.(DCSG01380171 (Port Of Defect DCSG01380276) When drives is removed during online Capacity Expansion, LSA doesn't display proper drives details.(DCSG01452727 (Port Of Defect DCSG01465151) Dedicated hotspare drive is not listed in P_D tab of DG on creating simple configuration with DHSP(DCSG01271866 (Port Of Defect DCSG01280187) OCE drives are not updated in LSA DG tab.(DCSG01286744 (Port Of Defect DCSG01313697) LSA Service start up issue with ubuntu 22.04(DCSG01473595 (Port Of Defect DCSG01516896) unable to perform drive offline after virtual drive expansion operation is completed.(DCSG01412768 (Port Of Defect DCSG01417359) LUN1 shows 0B instead of showing 6.366TiB in the popup window if user clicks NS/LU count(DCSG01419336 (Port Of Defect DCSG01419964) WG: 7.22: Unable to configure the write cache property to "always write back" for a Virtual Disk and LSA does not provide option to configure background initialization(DCSG01188973 (Port Of Defect DCSG01323631) Fixed: display error text for corresponding err code 20(DCSG01255146 (Port Of Defect DCSG01266543) 8.3 : LSA allows adding virtual drives of different stripe sizes during virtual drive creation, operation fails with error "Invalid parameter: StripSize; not found"(DCSG01287163 (Port Of Defect DCSG01295709) crash with IO and soft reset on 16 Partial R10 volumes with NVME drives(DCSG01505329 (Port Of Defect DCSG01519199) Free capacity count is shown as zero under array properties when there is free space(DCSG01403140 (Port Of Defect DCSG01404428) Rhel 9 issue when system doesn't have driver and controller installed(DCSG01372966 (Port Of Defect DCSG01430577) App consistency issue in comparison with 8.x for "Make Unconfigured" Physical drive operation and UI issue Unmap Virtual drive properties(DCSG01287526 (Port Of Defect DCSG01288944) 8.6 LSA : NS/LU Count popup window is not coming/opening if user clicks the count "2" for Multilun drive(DCSG01458171 (Port Of Defect DCSG01462003) LSA hangs during "Download Server report".(DCSG01558222 (Port Of Defect DCSG01566579) Downloading Virtual Drive properties from non admin login to LSA shows error code 5059.(DCSG01251156 (Port Of Defect DCSG01263941) anitize proceeds on unsupported drive and throws error " Error Code: 10 Description: Invalid parameter 0x0".(DCSG01227108 (Port Of Defect DCSG01229148) LSA GUI show empty probability when relaunch LSA after wake from hibernation(DCSG01497105 (Port Of Defect DCSG01499103) Patrol read scheduling inconsistency between storcli and LSA(DCSG01366824 (Port Of Defect DCSG01376149) Locale comes as " Drive " in Microcode update events for UBM Backplane firmware(DCSG01282828 (Port Of Defect DCSG01284115) Drive count mismatch is there in LSA when compared to the actual drive count(DCSG01485447 (Port Of Defect DCSG01500360) select all for un map drives does not work, user will need to individually select though only un map drives are listed(DCSG01267203 (Port Of Defect DCSG01276047) LSA 7.26/8.6: Corresponding OS support for gcc needs update(DCSG01453817 (Port Of Defect DCSG01473511) Handle downgrade blocking scenario (CQ:DCSG01219164)(DCSG01222193 (Port Of Defect DCSG01222211) LsiSASH service doesnot start due to error in the service name in Ubuntu 22.04(DCSG01246862 (Port Of Defect DCSG01273450) Changing drive security while sanitize in progress fails with empty error description(DCSG01485489 (Port Of Defect DCSG01486540) LSA Common: Update the LWA build script to pick local toolchain(DCSG01286580 (Port Of Defect DCSG01286583) LSAServer: Update toolchain (RC) for LWA and LWM ESXi builds(DCSG01320042 (Port Of Defect DCSG01320261) Selecting start now checkbox while scheduling Patrol read shows error code :31(DCSG01290301 (Port Of Defect DCSG01291079) while replace drive is in progress on unmap Virtual Drive , Virtual Drive operations for unmap Virtual Drive continues to show "Disable Unmap/Write Same Unmap" even after disabling unmap/wsunmap(DCSG01288161 (Port Of Defect DCSG01288386) After Driver Disable/Enable from Device manager LSA fails to load the controller.(DCSG01421098 (Port Of Defect DCSG01425992) LSA 7.24: Naming convention for snapdump file is different in 7.x and 8.X(DCSG01333588 (Port Of Defect DCSG01342652) After Reprovision of Secured Drive, Autoconfig behavior(execute once) option is not available.(DCSG01244895 (Port Of Defect DCSG01260600) LSA 8.7: JBOD's are not listed in the View list of Device Reporting Order page on IT controller however it allows to set.(DCSG01544915 (Port Of Defect DCSG01549746) Enclosure property not listing the Enclosure Name in latest release(DCSG01373512 (Port Of Defect DCSG01373528) Controllers are not sorted as per BDF in LSA.(DCSG01409588 (Port Of Defect DCSG01412742) Sanitize Drive option is still enabled and not working, when overwrite count field is empty.(DCSG01225926 (Port Of Defect DCSG01259421) While scheduling Consistency Check, getting Error Code: 3 Description: The requested command has invalid arguments.(DCSG01448731 (Port Of Defect DCSG01457292) LSA installation script on Rhel 9 OS is not showing packages to be installed prior to LSA installation.(DCSG01276093 (Port Of Defect DCSG01302145) GUI: JBOD BAD Drive status is not reflecting through the drive icon status(DCSG01280932 (Port Of Defect DCSG01283815) When user call GET of virtual drive erase operation, LSA is not usable(DCSG01561803 (Port Of Defect DCSG01567998) -(DCSG01291543 (Port Of Defect DCSG01303860) Fixed: Fine tuning mass event parameter(DCSG01266516 (Port Of Defect DCSG01268810) LSA 8.7:LSA is encountering 50x page on making a drive offline on the ARM Ubuntu system(DCSG01518904 (Port Of Defect DCSG01538997) ubuntu22.04 :DirectAgent : User cannot upgrade or downgrade using "ControllerActions >Update Firmware", Gateway works fine(DCSG01280233 (Port Of Defect DCSG01281594) WG: 8.3 LSA crashes on clicking controller more actions (Large Configuration)(DCSG01236595 (Port Of Defect DCSG01252477) WG_8.3: UI changes as part of Windows LSA uninstall from install shield wizard(DCSG01270847 (Port Of Defect DCSG01277845) 7.26/8.6 : event delivery fails for an individual event with severity configured to 'DEAD'/'FAULT'(DCSG01491863 (Port Of Defect DCSG01495930) LSA 8.7:LSA is encountering 50x page on making a drive offline on the ARM Ubuntu system(DCSG01518904 (Port Of Defect DCSG01538996) LSA IT flash is not updated until GUI refresh(DCSG01249961 (Port Of Defect DCSG01252420) Fixed: improved turn around time from client for Drive state change operations(DCSG01291543 (Port Of Defect DCSG01303749) Wrong error description during creation of mode volume less than the Stripe size.(DCSG01431325 (Port Of Defect DCSG01442015) RWC3 is accessible over http instead of https(DCSG01336437 (Port Of Defect DCSG01375604) 8.4/7.24: Uninstall the RWC3 does not remove the complete folder structure(DCSG01358044 (Port Of Defect DCSG01450240) enclosure location coming as unknown under drive properties(DCSG01224961 (Port Of Defect DCSG01226023) Invalid error message after clicking on MRSA reload button.(DCSG01419389 (Port Of Defect DCSG01428009) Handle downgrade blocking scenario (CQ:DCSG01219164)(DCSG01222193 (Port Of Defect DCSG01222210) 8.4: Auto configure behavior (Execute Once) create options get disabled if an error is encountered, user needs to reload 'Change Personality' page(DCSG01368412 (Port Of Defect DCSG01370652) Under physical drive properties, Location is displayed as unknown in enclosure properties(DCSG01206477 (Port Of Defect DCSG01219539) MR7.22 Alpha_LSA will spinup a spundown drive due to a OS/FS call(DCSG01204216 (Port Of Defect DCSG01218528) Readme needs update in LSA_Linux_aarch64 RO(DCSG01472341 (Port Of Defect DCSG01509628) Expand Drive operations results in pop up message hang.(DCSG01216085 (Port Of Defect DCSG01219320) Invalid error message is shown on updating wrong firmware on AV controller whereas storcli shows properly(DCSG01444359 (Port Of Defect DCSG01444376) -(DCSG01267203 (Port Of Defect DCSG01269976) 8.7 : Manage SAS Storage Link Speed page does not load, fails with 405 Method Not Allowed(DCSG01497732 (Port Of Defect DCSG01516909) -(DCSG01512233 (Port Of Defect DCSG01529003) LSA Server: UnSupported Drive Health Status is not reflecting(DCSG01268098 (Port Of Defect DCSG01270865) Online batch operation does not display force warning pop up(DCSG01289255 (Port Of Defect DCSG01339471) 8.5_LSA: LSA crashes during "Download server report"(DCSG01422176 (Port Of Defect DCSG01436738) LSA installation is failing with conflicts from package storelibit(DCSG01390402 (Port Of Defect DCSG01398650) Avenger_8.2 : LSA is Showing as controller is in safe mode when Controller is not in safe mode(DCSG01219202 (Port Of Defect DCSG01219292) Capacity for greater than 2 TB drives is shown incorrect(DCSG01486424 (Port Of Defect DCSG01488170) LWM 8.3 : Segementation fault seen in ./LSA console after maximizing putty.(DCSG01266778 (Port Of Defect DCSG01273338) LSA 8.8: LSA_ESXi8x package name is different in signed & unsigned builds & Component Installation instructions needs update(DCSG01557052 (Port Of Defect DCSG01567991) LSA MR 7.22: Adding Virtual drive of KB size for the DG is throwing error code:3 Description: The requested command has invalid arguments.(DCSG01194710 (Port Of Defect DCSG01219364) V_D Strip size detail is missing in Server profile page when there is a CC V_D, it works fine if there is no CC V_D(DCSG01293318 (Port Of Defect DCSG01294307) LSA 8.5/7.25: Copyrights need to be updated.(DCSG01392501 (Port Of Defect DCSG01395220) WG:LSA does not allow to configure interval of schedule CC page using increment/decrement arrows on switching between Schedule CC and PR pages, able to configure non numberic value(DCSG01226056 (Port Of Defect DCSG01228070) WG_8.3: Wrong code description is shown for Error code 15 whereas in storcli it shows correct.(DCSG01269950 (Port Of Defect DCSG01278028) :LSA OEM build have reference in Change Security Page(DCSG01278015 (Port Of Defect DCSG01280185) Missing Advanced Software options details(DCSG01517378 (Port Of Defect DCSG01518987) MRSA LSA_MONITOR filling up the Windows application log due to duplication(DCSG01521167 (Port Of Defect DCSG01528844) 8.x controller shows more needs attention message for Unconfigured bad unsupported drives(DCSG01280271 (Port Of Defect DCSG01280343) Unable to Suspend/Resume/stop PR from LSA.(DCSG01213067 (Port Of Defect DCSG01216218) Firmware package build time shows always constant value for 94xx controller(DCSG01340804 (Port Of Defect DCSG01342512) 8.5 LSA : Snapdump trigger time is not showing (for Firmware trigger type) in LSA as it is showing blank, however Storcli shows time properly(DCSG01371510 (Port Of Defect DCSG01380233) LSA 7_22: Ubuntu 22.04 installation failure seen(DCSG01205685 (Port Of Defect DCSG01215208) MR7.22_LSA008.002.009.000 Does not flash the PSOC firmware(DCSG01200036 (Port Of Defect DCSG01219571) LSA: Esxi8.0 "Selected EFI_BSD/BIOS" version not displayed during flash(DCSG01508656 (Port Of Defect DCSG01511870) LSA: Consistency check Next start time is shown wrong(DCSG01407577 (Port Of Defect DCSG01417347) WG:8.2: After applying filter OCE drive is shown as part of physical drive group(DCSG01228272 (Port Of Defect DCSG01231277) Virtual drive operations shows more actions, clicking on it the subset of already listed Virtual drive operations are shown(DCSG01283668 (Port Of Defect DCSG01287558) LSA crash observed when trying to access foreign locked drives(DCSG01215163 (Port Of Defect DCSG01218290) LSA 7.25/8.5 : LWA is not launching in ESXi 7.0(DCSG01409492 (Port Of Defect DCSG01437134) OCE progress display issue(DCSG01258351 (Port Of Defect DCSG01300035) WG_Avenger: Cryptographic erase fails with uninterrupted is not supported even though uninterrupted is not selected(DCSG01179845 (Port Of Defect DCSG01215666) 8.2 Server: OS/FS Virtual Drive is not being populated(DCSG01192504 (Port Of Defect DCSG01255953) LSA fails Patrol Read scheduling when transformation is in progress.(DCSG01321091 (Port Of Defect DCSG01331150) Discrepancy in Capacity of the virtual drive after expansion on changing percentage of available capacity in Expand virtual drive page(DCSG01401191 (Port Of Defect DCSG01403231) Unable to create secured WSunmap Virtual Drive during Advance configuration pages.(DCSG01286046 (Port Of Defect DCSG01288387) LSA: Option copyback did not show up when 1st pan of R50 has started Copyback(DCSG01359683 (Port Of Defect DCSG01364038) PCI Slot NO is coming wrong in the controller Drop down(DCSG01388034 (Port Of Defect DCSG01388115) PR5_PA1: Reconstruction and BGI Progress not getting updated(DCSG01546635 (Port Of Defect DCSG01555154) LSA:Fail to auto update or refresh events when we insert back the enclosure.(DCSG01222488 (Port Of Defect DCSG01225139) WG: 8.2: adding max VDs to an existing DG having one VD, operation fails with "Invalid parameter: StartBlock; not found"(DCSG01197616 (Port Of Defect DCSG01215662) WG: 7.22: Deleting multiple Virtual Drives (32 at a time), the LSA page continues to show "refresh in progress" for more 50 seconds after Virtual Drive delete is reflected in LSA Page.(DCSG01227454 (Port Of Defect DCSG01236297) Connected device shows "Enclosure or Logical Enclosure Properties" instead of target device(DCSG01551822 (Port Of Defect DCSG01567905) LSA: Issue regarding "Firmware activation status" page.(DCSG01213874 (Port Of Defect DCSG01215161) Bays on Port should be removed from Enclosure Properties for UBM6 backplanes(DCSG01248249 (Port Of Defect DCSG01249899) Allow unrestricted sanitize Exit is enabled at first time & after traverse to other options, then it is disabled for same drive(DCSG01257518 (Port Of Defect DCSG01314928) while rebuild is in progress in virtual drive of a DG, user is not allowed to add virtual drive to any other DG (new/old). CLI allows(DCSG01286271 (Port Of Defect DCSG01286302) cimplugin.so is not bundled with Linux Build(DCSG01209234 (Port Of Defect DCSG01219475) LSA Client Drive status is shown empty for drive in cnfSheild state(DCSG01288292 (Port Of Defect DCSG01288382) For 9600 24i controller, view all controller properties shows junk character in the revision & rework date shows 202018 instead of 2018(DCSG01320038 (Port Of Defect DCSG01320262) WG_8.4: LSA installation throws error on ubuntu 22.04 OS on ARM server(DCSG01343605 (Port Of Defect DCSG01354001) WG:8.2: Sanitize Unconfigured drive is not counted as part of drive list Unconfigured good count(DCSG01225669 (Port Of Defect DCSG01225852) LWA ESXi8: LWA hungs in Firmware File Upload in progress page while Updating firmware(DCSG01518941 (Port Of Defect DCSG01525836) After OFU, only after manual refresh the latest version is reflected even after waiting for 5 minutes(DCSG01366950 (Port Of Defect DCSG01371077) LSA not displaying drive in 0KIB state under unconfigured drives list, Also number of drive under logical drives is displayed as 7(DCSG01419076 (Port Of Defect DCSG01423586) Fixed: Incorrect Alignment causing issue(DCSG01430903 (Port Of Defect DCSG01485778) Resume/Suspend Rebuild of multiple Physical Drives from element actions is throwing error.(DCSG01251335 (Port Of Defect DCSG01263928) -(DCSG01446395 (Port Of Defect DCSG01450003) LSA 7.25/8.5: Unable to configure schedule wrapper in LWA ESXi 8.0(DCSG01404008 (Port Of Defect DCSG01409637) Drive firmware update does not reflect after the success.(DCSG01228198 (Port Of Defect DCSG01230154) 8_2: Set Factory Button is activated when Preserve Cache available on the controller(DCSG01226117 (Port Of Defect DCSG01227671) Drive Status (UG bad) is not showing consistently in different pages of LSA(DCSG01215776 (Port Of Defect DCSG01294482) Logical Drive filter list shows KiB instead of KB for logical drive strip Size in the filter windows.(DCSG01333632 (Port Of Defect DCSG01335727) "Add Physical Drive" button is disabled while trying to "expand" the D_G.(DCSG01428124 (Port Of Defect DCSG01430833) 8.6/7.26: Changing the manage SAS/PCIe Storage link speed error handling status response has empty 'additional info'(DCSG01488815 (Port Of Defect DCSG01512900) PCI Slot NO is coming wrong in the controller Drop down(DCSG01381679 (Port Of Defect DCSG01388091) WG 8.3: Unable to create single Drive Raid 0(DCSG01286688 (Port Of Defect DCSG01289166) -(DCSG01555671 (Port Of Defect DCSG01557000) EnhancementRequests: M R8_4: Common: Handle latest state code(DCSG01301230 Static analysis of code and fix(DCSG01343636 Readiness for ESXi accepted certification(DCSG01450178 LSA: Support Spin up drives option from LSA client/server(DCSG01285710 Add a generic event to identify the reset type.(DCSG01315618 Completed: Migration of LWA to Esxi 8.0(DCSG01176436 implemented: esxi 8x support for LSA and daemon commands(DCSG01225138 Safe Store enhancement to indicate drive AUTHORITY_LOCKED_OUT state(DCSG01467235 VMware ESXi 8.0 U1 SCon Automation Build script changes(DCSG01491192 LSA Client Addition of controller property to set the device reporting order.(DCSG01502823 Windows: Restrict LSA home directory to the non Admin users(DCSG01300658 Implemented: SMTP Support update(DCSG01216045 LSA: Black Duck scan to identify risks(DCSG01271787 MegaRAID 8.5: Update FIPS enabled servers in StandAlone environment(DCSG01358189 Coed analysis and resolution(DCSG01450011 LSA Client WS Unmap support(DCSG01231436 SL IT: StoreLib API changes for HDB(DCSG01412718 LSA Common: Enhance LSA StandAlone to generate LWA and ARM builds(DCSG01319407 Phase 2 Thirdparty Refresh for ARM/LWA/RHEL 9(DCSG01312479 Enhancing nginx : updated nginx with appropriate configuration resource directory entry(DCSG01513062 StandAlone Support for 'OEM' builds(DCSG01353292 LSA Client : Add Drive RPM details(DCSG01314516 Schedule Patrol Read with start now option while rebuild or copy back going on.(DCSG01331822 Code optimization and exception handling(DCSG01346667 Static analysis of code and fixing by following coding guidelines(DCSG01341798 8.3 Client: Security Version display(DCSG01242227 LSA Client Enhanced Scheduling Behavior (CC\PR)(DCSG01288551 LSA Client: Enhance Controllers call with query parameter(DCSG01310772 8.3 Server :UNMAP Support SAS only(DCSG01225097 LSA Client : Add a generic event to identify the reset type.(DCSG01376241 Applications: VMware ESXi 8.0 U1 OS Support MegaRAID 7.26, MegaRAID 8.6, SAS3.5 Ph27 (OS GA 04/30/2023)(DCSG01388803 enhancements for ESXi 8.0 signing support(DCSG01496431 24G JBOD Support for H965e(DCSG01320828 Support new MR_ENCL_SUBTYPE API(DCSG01472759 Applications: Add Physical Disk rotational speed to detailed display(DCSG01270348 LSA Linux: GCC upgrade in standalone environment(DCSG01398727 SecureBoot: Firmware download operation fails with incorrect message(DCSG01132473 MR8 5.39 API Upgrade(DCSG01225084 LSA Server: Enhance Controllers call with query parameter(DCSG01323796 Applications: OEM requesting FIPS support on Linux(DCSG01315664 8.4 PERF: LSA Client: Update volatile data on demand(DCSG01310746 Support newly added API where SL8 has revisited SCSI command retry logic.(DCSG01408565 LSA Client add email support for IONOS(DCSG01216047 8.7 OLH Integration(DCSG01521534 DSDK based application Development and signing(DCSG01391356 handle extended status for foreign import(DCSG01246289 8.4 PERF: LSA Client: Enhance the progress event in Monitor(DCSG01310769 Script and makefile changes to take latest 3rd party binary for arm and linux(DCSG01331938 Applications: Ensure a dynamic and consistent view of the drive link speed when the initially negotiated speed gets changed(DCSG01373599 Handle new Event EVT_LD_PROP_NAME_CHANGE(DCSG01220306 Add Isfault Bit in enclosure properties(DCSG01399282 8.4 Common: Enhance LWM Linux to compatible with RHEL9.1(DCSG01331320 Applications: GCA Support for Multi AU on JBOD/AHPD(DCSG01383874 Handling Unmap/wsUnmap for Single drive RAID 0(DCSG01262775 Adding Kib also as unit for selection during volume creation for consistency(DCSG01464327 Changes for accommodating Firmware Multi LUN changes(DCSG01329472 Client: improve handling of devices spun down by host or firmware when apps scan(DCSG01371269 VMware ESXi 8.0 OS Support MegaRAID 6.14, MegaRAID 7.22, MegaRAID 8.3, SAS3 Ph16, SAS3.5 Ph24 (OS GA 03/31/2022)(DCSG01249904 LSA Linux: GCC upgrade in standalone environment for OEM(DCSG01418426 Applications: OS driver support for SLES15 SP5(DCSG01451934 Optimize the code by fixing the bugs identified by analyzer tool Phase 1(DCSG01344987 Aero 9500 HBA controllers Support for multiple PSOC images(DCSG01214165 Schedule PR And StartNow Re Visit(DCSG01381014 LSA_Common: new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01220877 Storage Management Libs API: Prevent installation of inappropriate firmware image on OEM branded IT adapters(DCSG01492393 Applications: Ensure a dynamic and consistent view of the drive link speed when the initially negotiated speed gets changed(DCSG01327215 Add support for Redfish Enhanced Events (RDE Alerts)(DCSG01458630 SL API: Add HDB SL APIs for Trigger(DCSG01420350 Enclosure slot map Handling faulty enclosure fields population in server(DCSG01381251 Implementation: handle the new status code when Broadcom channel Firmware is flashed on different OEM card.(DCSG01421211 Mux mode command support removal(DCSG01368740 LSA Server: WS Unmap support(DCSG01245624 implemented: Force PSOC image update using LSA after providing warning(DCSG01245653 M R8_4: Server: Handle latest state code(DCSG01301233 StandAlone: Add ESXi7 flavor of LWA and LWM ESXi packages with ESXi8 release(DCSG01359849 Binary size optimisation to improve vib footprint on esxi(DCSG01455664 LSA Server: Update volatile data on demand(DCSG01310743 Upgrade OEM support matrix(DCSG01453705 LSA Common add email support for IONOS(DCSG01218722 Foreign preview enhancement(DCSG01443994 LSA_Release: new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01220783 Implemented: Preview Importable Foreign Drive which are not associated with configuration(DCSG01285996 Upgrade latest Compiler and std in LSA(DCSG01384281 LSA Client: Handle DEAD severity events(DCSG01299386 The 'Device Speed' is shown as 24.0Gb/s for SAS4 drives(DCSG01388206 8.3 Server: Security Version display/handle(DCSG01240843 MR8 5.40 API Upgrade(DCSG01227796 8.3 Client :UNMAP Support SAS only(DCSG01225148 LSA: Enhanced Scheduling Behavior(DCSG01302604 Enhanced Request handlers in LSA to avoid DoS(DCSG01254224 Applications: add 6 hdparm & sg_sanitize & sg_format commands support(DCSG01480960 MegaRAID8.4 Server: Enhance LWM Linux to compatible with RHEL9.1(DCSG01329989 Implementation: support and capability display for ATA security on LSA(DCSG01480959 (DCSG01393128 MegaRAID8.4 PERF: LSA Server: Enhance the progress event in Monitor(DCSG01310763 Enhanced Error reporting (cover all the error codes and make consistent error descriptions)(DCSG01470539 Applications: Enhancing StorCLI2 for ESXi8.0 to use the esxcli plugin(DCSG01450179 LSA Properties Display Review Advanced Properties option Part2(DCSG01155006 Applications: Support for Multi AU on JBOD/AHPD(DCSG01444675 Storelib API Support ISTWI READ WRITE Request(DCSG01548106 Applications: Addition of controller property to set the device reporting order.(DCSG01437654 Applications: Add a generic event to identify the reset type.(DCSG01315619 Applications: Improve DCMD timeout implementation(DCSG01329511 Handle DEAD severity events(DCSG01317965 8.6/7.26 OLH integration(DCSG01480828 Populate unmap and wsunmap drive capabilities(DCSG01363295 LSA 8.4: Preview Importable Foreign drives which are not associated with configuration(DCSG01286006 WriteSame Unmap Client Consistency Changes(DCSG01245408 HSW Consistency: ASO display(DCSG01336603 LSA 8.5/7.25 OLH Integration(DCSG01402540 Safe Store enhancement to indicate drive AUTHORITY_LOCKED_OUT state(DCSG01467236 Physicaldisk rotational Speed API changes update(DCSG01385722 Move to 7.26 channel base [localhost and session enhancement](DCSG01471534 Add support for Redfish Enhanced Events (RDE Alerts)(DCSG01466476 Track LSA backend memory usage and management.(DCSG01320274 Client Binary Size reduction for Vmagent(DCSG01429286 Clinet: Handle new Event EVT_LD_PROP_NAME_CHANGE(DCSG01227103 Applications: RWC3 8.x Support(DCSG01285687 Issue with uncaught exception.(DCSG01451318 Third Party components Refresh in LSA(DCSG01301956 Applications: Snapdump ID's to get listed/sorted based on the oldest in the top(DCSG01331418 MegaRAID API 5.42/.43 alignment with LSA(DCSG01302482 LSA Properties Display Review Advanced Properties option Part2(DCSG01155007 LSA Common: Handle DEAD severity events(DCSG01299381 Client: new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01244959 Applications: GCA Support for Multi AU on JBOD/AHPD(DCSG01383873 LSA new events addition in cache module(DCSG01376350 Compilation warnings resolution(DCSG01336609 Applications: Support for PsoC catalog version checking on update.(DCSG01245652 new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01155009 Enclosure slot map Handling faulty enclosure fields population in client(DCSG01381009 MR8 API 5.47 Review and analysis(DCSG01400081 LSA Monitor: Individual Alert Configuration for different generation(DCSG01276035 Storage Management Libs API: Port of ScrutinyCLI commands to StorCLI(DCSG01410184 Applications: Provide Generic UBM Backplane And EDSFF Drives Support(DCSG01467245 LSA add email support for IONOS(DCSG01176708 Enhancing StorCLI2 for ESXi8.0 to use the esxcli plugin(DCSG01461796 Applications: Prevent installation of inappropriate firmware image on RWC branded 95xx(DCSG01491415 Battery Serial Number display issue.(DCSG01452158 Thirdparty zip file merge and create separate pacakges to support multiple compiler versions(DCSG01409010 Applications: 12.1: 24G JBOD Support for H965e(DCSG01288807 Applications: Enable Makers authority(DCSG01384707 Arm build generation for new gcc compiler(DCSG01251962 LSA gateway timeout increased to 540 sec(DCSG01179123 LSA Server: Handle DEAD severity events(DCSG01299404 OEM requesting FIPS support on Linux(DCSG01453718 LSA_Release: new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01220783 (Port Of EnhancementRequest DCSG01231389) -(DCSG01359849 (Port Of EnhancementRequest DCSG01360855) LSA code optimization and warning/error handling.(DCSG01270110 (Port Of EnhancementRequest DCSG01289759) Arm build generation for new gcc compiler(DCSG01251962 (Port Of EnhancementRequest DCSG01264780) Applications: VMware ESXi 8.0 U1 OS Support MegaRAID 7.26, MegaRAID 8.6, SAS3.5 Ph27 (OS GA 04/30/2023)(DCSG01388803 (Port Of EnhancementRequest DCSG01455665) Implemented acceptance level signing as it will comply with requirement(DCSG01546640 (Port Of EnhancementRequest DCSG01546645) Enhanced Error reporting (cover all the error codes and make consistent error descriptions)(DCSG01470539 (Port Of EnhancementRequest DCSG01471265) Phase 2 Thirdparty Refresh for ARM/LWA/RHEL 9(DCSG01312479 (Port Of EnhancementRequest DCSG01360002) Enhancing StorCLI2 for ESXi8.0 to use the esxcli plugin(DCSG01461796 (Port Of EnhancementRequest DCSG01486596) LSA Monitor: Individual Alert Configuration for different generation(DCSG01276035 (Port Of EnhancementRequest DCSG01276039) new RFC5321 3.3 requires different mail command which is not supported by LSA yet.(DCSG01155009 (Port Of EnhancementRequest DCSG01242650) Third Party components Refresh in LSA(DCSG01301956 (Port Of EnhancementRequest DCSG01305092) LSA Linux: GCC upgrade in standalone environment for OEM(DCSG01418426 (Port Of EnhancementRequest DCSG01419580) -(DCSG01220877 (Port Of EnhancementRequest DCSG01244492) De branding of OEM from LSA Generic(DCSG01311171 (Port Of EnhancementRequest DCSG01311181) LSA Linux changes EnhancementRequest DCSG01301956: Third Party components Refresh in LSA(DCSG01301956 (Port Of EnhancementRequest DCSG01302621) LSA_Common: Upgrade StandAlone script to pick GIT folder structure(DCSG01272333 (Port Of EnhancementRequest DCSG01272598) 8.3 Server: Security Version display/handle(DCSG01240843 (Port Of EnhancementRequest DCSG01240844) LSA to Recompile and bundle and StorLib with 2.17+ or newer glib to avoid severe CVEs(DCSG01538278 (Port Of EnhancementRequest DCSG01557011) -(DCSG01341798 (Port Of EnhancementRequest DCSG01470620) Applications: Support for Multi AU on JBOD/AHPD(DCSG01444675 (Port Of EnhancementRequest DCSG01452631) MegaRaid_8_3: Enhance LSA event logging libraries(DCSG01230107 (Port Of EnhancementRequest DCSG01236422) 8.7 OLH Integration(DCSG01521534 (Port Of EnhancementRequest DCSG01555799) -(DCSG01312479 (Port Of EnhancementRequest DCSG01324343) LSA GUI UBM6 Support for(DCSG01228197 (Port Of EnhancementRequest DCSG01228211) Add RHEL9 support to Linux flavor in StandAlone environment(DCSG01339904 (Port Of EnhancementRequest DCSG01342633) Applications: Enhancing StorCLI2 for ESXi8.0 to use the esxcli plugin(DCSG01450179 (Port Of EnhancementRequest DCSG01461794) LSA Server UBM6 Support(DCSG01228196 (Port Of EnhancementRequest DCSG01228210) -(DCSG01301956 (Port Of EnhancementRequest DCSG01303330) Handling Unmap/wsUnmap for Single drive RAID 0(DCSG01262775 (Port Of EnhancementRequest DCSG01262777) LSA Linux: GCC upgrade in standalone environment(DCSG01398727 (Port Of EnhancementRequest DCSG01398730) Completed: Migration of LWA to Esxi 8.0(DCSG01176436 (Port Of EnhancementRequest DCSG01230271) -(DCSG01546640 (Port Of EnhancementRequest DCSG01546644) StandAlone Support for 'OEM' builds(DCSG01353292 (Port Of EnhancementRequest DCSG01353298) -(DCSG01391356 (Port Of EnhancementRequest DCSG01398636) Arm build generation for new gcc compiler(DCSG01251962 (Port Of EnhancementRequest DCSG01252481) Applications: Move to 7.26 channel base(DCSG01458618 (Port Of EnhancementRequest DCSG01536296) -(DCSG01471534 (Port Of EnhancementRequest DCSG01471541) -(DCSG01496431 (Port Of EnhancementRequest DCSG01498535) VMware ESXi 8.0 U1 SCon Automation Build script changes(DCSG01491192 (Port Of EnhancementRequest DCSG01495414) Arm build generation for new gcc compiler(DCSG01251962 (Port Of EnhancementRequest DCSG01252483) VMware ESXi 8.0 U1 SCon Automation Build script changes(DCSG01491192 (Port Of EnhancementRequest DCSG01516915) Script and makefile changes to take latest 3rd party binary for arm and linux(DCSG01331938 (Port Of EnhancementRequest DCSG01331940) 8.3 Server :UNMAP Support SAS only(DCSG01225097 (Port Of EnhancementRequest DCSG01225100) 008.002.017.000 - Moderate Impact --------------- MR 7.22 Defects: Fixed :LSA set lane speed to 16GT/s(DCSG01111833 LSA : Secured foreign UG Bad drive is not showing Crypto erase option at first, after doing Crypto erase from Storcli & then LSA shows CE option for that UG Bad drive(DCSG01103089 PSOC6 LSA 7.20: PSOC current and selected version spelling is displayed as "vesrion" during PSOC update(DCSG01137889 Fixed: allow multiple DG creation(DCSG01074166 LSA_MR7.20_PA:Multiple PDs and VDs selection is not working.(DCSG01039219 WebGUIRelease_7.20_PA-007.020.004.000-DCSG01042991: "LSA will generate alerts from events since last clean shutdown" & "Starting Gateway installation of LSIStorageAuthority" has "\n" character.(DCSG01043665 Drive count is showing "0" always under "other hardware" tab in LSA when user connects Tape drive, however storcli shows it properly(DCSG01093643 Virtual Drive Capacity GUI issue when Disk Cache Policy selected(DCSG00973715 LSA:AeroMR_7.20:BGI progress information is displayed on issuing PAUSE command(DCSG01052255 LSA Reference in MRSA readme for Linux(DCSG01080850 22B Alpha Tape Drive LSA: Mismatch in sector size displayed in server profile and unconfigured good page.(DCSG01112937 LSA: WebGUIRelease_7.20_PA-007.020.004.000-DCSG01042991: Email settings should have a check for @.(DCSG01048568 WG: updating PSOC firmware shows Online firmware update is in progress(DCSG01140787 22B-PSOC6- LSA shows inappropiate message for wrong PSOC image flash(DCSG01132438 Fixed: allow >32 drive R10(DCSG01039688 Update the nginx with the SSL flags(DCSG01071924 WG_RWC3: RWC3 fails to launch from desktop shortcut(DCSG01027396 Refresh issue of "Port number" under Manage SAS Storage Link Speed though Tape drive has been removed from the setup.(DCSG01096142 LSA: PD Crypto Erase failed due to error "Description: This is an OS Drive. Erase cannot be performed"(DCSG01061602 fixed: Max drives for R00(DCSG01040107 LSA Server: Microsoft Windows API usage (Release function)(DCSG01015555 fixed: LSA : Controller critical/need attention message is showing wrongly as it has multiple duplicate entries(DCSG01111618 LSA_MR_7.20_PA2: "Make JBOD" option is displayed for Foreign drive(DCSG01030118 LSA : JBOD conversion option is coming for Tape drive if the drive is in UG mode, if user clicks JBOD & it shows failure message with error code 38(DCSG01113102 LSA-MR7.20:Unable to close message dialog on selecting configured PDs > 32 PDs to 240 PDs under Drive Group Tab> PD Tab(DCSG01044347 Fixed: timout seen during import(DCSG01033216 LSA : Controller Drop down menu lists the controller above the drop down menu, due to this controller is not seen sometimes though user clicked the ctrlr drop down menu(DCSG01107334 LSA : Type is not showing any info in Drives information under server profile for Tape drive, whereas the main page of controller shows the type properly(DCSG01111968 install SLP from installation source beforr. "before" to be corrected.(DCSG01039227 LSA : RHEL 8.5 OS is not present in the Linux readme file(DCSG01137293 LSA : EPAK failed event shown SOH Bad(DCSG01145362 22B Alpha LSA CFF 440-16i: After PD removal/ insertion other hardware count is displayed as 0 in LSA.(DCSG01130124 Click on other hardware tab remove/insert drive to controller, observe that other hardware information is not displayed.(DCSG01142250 Select all is selecting all the drives when the number of drives is more than the selectable drives(DCSG00982356 22B-PSOC6 -OFU windows shows Imporper message during PSOC flash via LSA(DCSG01128864 WG: LSA Crashes on trying to flash PSOC from LSA(DCSG01126644 WebGUIRelease_7.20_PA-007.020.005.000-DCSG01058115: New line is not handled properly in the installation scripts.(DCSG01058946 LSACommon: Restore users files while upgrading LSA(DCSG01073725 Fixed: LSA : Health of enclosure is showing as "Unknown" always for good/bad enclosures(DCSG01111545 7.20 Readme is not having Win 2022 OS in supported OS list, however 7.19 LSA readme has Win 2022 OS(DCSG01105553 OEM details for Embedded controllers in windows OS(DCSG01075803 Email settings should not have a check for @.(DCSG01090903 fixed: Enclosure status is displayed as blank in server profile.(DCSG01111966 For IT controller tty log file is part of Download Server Report(DCSG00966716 LSA:AeroMR_7.20PA: Previous configuration BGI is displayed post clear config(DCSG01039961 LSA-7.20_PA - 007.020.002.000 shows jbod for unsupported MA drives(DCSG01035032 LSA : If user clicks "connected device" under Manage SAS Storage Link Speed, it is not showing any details when user has Tape drive(DCSG01096124 discovery issue: When the remote server is down the server is not removed from discovered list(DCSG01030008 Boca 540-16i: LSA displays enclosure/BP logical ID in reverse order.(DCSG01025576 (Port Of Defect DCSG01028918) LSA: Faulty Enclosure state is displayed as optimal in LSA(DCSG01080760 (Port Of Defect DCSG01088781) Lib_utils rpm not proper and does not have SSL files bundled for LSA aarch64(DCSG01015405 (Port Of Defect DCSG01016303) LSA : Statement needs to be modified under Enable security as it shows "Virtual drives" for IT controller(DCSG01136168 (Port Of Defect DCSG01140911) DCSG01109800 (Port Of Defect DCSG01119229) LSA: Faulty Enclosure state is displayed as optimal in LSA(DCSG01080760 (Port Of Defect DCSG01088782) Rebuild operation not seen on an offline drive with Raid 6 , 5 drives created(DCSG01099765 (Port Of Defect DCSG01102969) 4K Physical Drive JSON file raw size do not match with value shown in JSON(DCSG01016816 (Port Of Defect DCSG01017165) WG: JSON File in the servers and serverdetail log folder shows different port numbers(DCSG01075773 (Port Of Defect DCSG01091661) LSA Client: IT Connector status value for the PD is not displayed(DCSG01099751 (Port Of Defect DCSG01105329) LSA Server: IT Connector status value for the PD has an issue(DCSG01099750 (Port Of Defect DCSG01099752) LSA : Manage SAS storage link speed is not showing one of the connected device behind BP(DCSG01026787 (Port Of Defect DCSG01028684) LSA: PD Crypto Erase failed due to error "Description: This is an OS Drive. Erase cannot be performed"(DCSG01061602 (Port Of Defect DCSG01062281) Enclosure location is displayed as "unknown" instead of internal/external under enclosure properties in physical device properties(DCSG01080769 (Port Of Defect DCSG01089861) (DCSG01052255 (Port Of Defect DCSG01052266) Shenandoah_Snap5:LSA - Drive Firmware version not reported proper in LSA for an NVME drive(DCSG01123114 (Port Of Defect DCSG01130058) LSA Avenger_8.1 : Mutliple snapdump file download is showing action successful message, but files are not downloaded.(DCSG01060164 (Port Of Defect DCSG01068639) LSA MR 7.19: LSA crashed on clicking Drives TAB post 240 R0 VD deletion(DCSG01013919 (Port Of Defect DCSG01031302) Modify the License (or) copyright year to 2022(DCSG01109800 (Port Of Defect DCSG01109801) Enclosure location is displayed as "unknown" instead of internal/external under enclosure properties in physical device properties(DCSG01080769 (Port Of Defect DCSG01086649) MR7.19 PA2:LSA-02: "Make JBOD" option is not displayed for Aero MR(MegaRAID 9580-8i8e) & Aero iMR(9540-16i)(DCSG01002945 (Port Of Defect DCSG01018282) LSA MR 7.19: LSA crashed on clicking Drives TAB post 240 R0 VD deletion(DCSG01013919 (Port Of Defect DCSG01030620) LSACommon: Restore users files while upgrading LSA(DCSG01073725 (Port Of Defect DCSG01091973) Boca-540-16i : LSA -BP logical id shown as junk(DCSG01014125 (Port Of Defect DCSG01019750) Avenger_WG: As part of negative test, manual discovery of vmware server and login crashes LSA(DCSG01015031 (Port Of Defect DCSG01018410) Fixed: Update curl library with secure flags(DCSG00963302 (Port Of Defect DCSG01024511) EnhancementRequests: Update ControllerInfo Structure with PartNumber - API Changes(DCSG01064529 Enable end user tools to read custom SN - part 2(DCSG00950274 Enable end user tools to read custom SN - part 2(DCSG00950275 API change to support PD sanitize operations enhancements(DCSG01070995 Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API(DCSG01065378 Windows Client Win11 OS Support - MR6.14, SAS3 Phase 16, MR 7.20, SAS3.5 Phase 22 (OS GCA Date - 10/05/2021)(DCSG01043610 LSA GUI Support for Aero 9560/9580 - Add PSOC6 as Vision Controller(DCSG01077815 Image change - branding for Intel RAID Web Console 3 (LSA rebranded)(DCSG01008558 Aero 9560/9580 - Add PSOC6 as Vision Controller(DCSG01075692 Make offline bundle for LWA and LWM ESXi(DCSG01150074 (Port Of EnhancementRequest DCSG01150081) Implimented: TCP/HTTP Fortification(DCSG00436245 (Port Of EnhancementRequest DCSG01147883) Windows Client Win11 OS Support - MR6.14, SAS3 Phase 16, MR 7.20, SAS3.5 Phase 22 (OS GCA Date - 10/05/2021)(DCSG01043610 (Port Of EnhancementRequest DCSG01068997) 007.019.006.000 - Moderate Impact --------------- MR 7.19 -LSA : Able to update different Aero-IT HBA FW file (16i) to different model IT-Aero card (16e).(DCSG00986871) -LSA MR 7.17: Sorting is not working in the span tab of VD in presence of missing drive..(DCSG00946017 (Port Of Defect DCSG00757915)) -AERO _MR_LSA_7_18:Under Personality management > change behavior mode, "Change " button is disabled even though.(DCSG00960275 (Port Of Defect DCSG00907541) -Update VMware DCPN cases for ESXi 6.7U3 and ESXi 7.0U2.(DCSG00985708 (Port Of Defect DCSG00950625)) -WG: test email fails with NON-auth login when 'sender email address' is set to anything other than domain "@server.com" for.(DCSG00986188 (Port Of Defect DCSG00940109) -Drive import is success however the message shows incomplete when importing unlocked drive.(DCSG00988921 (Port Of Defect DCSG00734940)) -LSA reports wrong version for the OS..(DCSG00990503 (Port Of Defect DCSG00990486) 007.017.015.000 - Moderate Impact --------------- Defects: -WG: Enclosure connector info in PD properties shown "C0 & C0" instead of "C0 & C1".(DCSG00775146 -WG: Logging in to manage server page and clicking on VMware server for login results in VMware login page refresh indefinitely.(DCSG00397834 -WG: Snapdump not getting downloaded with ARM MR 7.17 LSA.(DCSG00653578 -Invalid Enclosure logical ID is displayed is LSA for enclosure connected to Hialeah 8e controller..(DCSG00967815 -LSA MR 7.17: Modifying VD size is not getting updated , if the VD size is more than the current VD size..(DCSG00718530 -WG: LSA service does not start automatically on reboot on OpenEuler.(DCSG00648374 -HBA not listed with index order under Server Profile.(DCSG00418634 -Remote Server Health status without controller is not proper.(DCSG00528112 -WG: RWC3 Linux supports obsolete SHA1-based ciphersuites.(DCSG00500737 -Ventura_LSA_7.17: Under change behavior mode, "Change " button is enabled even though configuration parameter in unchecked.(DCSG00706331 -LSA : OLH shows lane speed values as Unknown, 2.5GT/s, 5GT/s, 8GT/s for Manage PCIe Storage Interface instead of showing 2.5GT/s, 5GT/s, 8GT/s & 16GT/s.(DCSG00971355 -LSA does not launch on ARM Open Euler : 007.017.008.000 ARM build.(DCSG00905358 -LSA service is stopped, after LWM (option4) installation in Ubuntu 20.04 arm system..(DCSG00506960 -Fixed: Added interface check for appropriate mix policy.(DCSG00706336 -behavior mode values is not being set properly.(DCSG00426348 -change button is not enabled for Behavior params change.(DCSG00426709 -WG: DLL files packaged in monitor folder of ARM LSA installation.(DCSG00706354 -Linux, RHEL 8.3 - Blank screen shown on launching latest LSA.(DCSG00777144 -LSA MR 7.17: Make JBOD option is available for all the UGOOD PDs, even though one of the PD is in drive clear process..(DCSG00775455 -Login page help link is showing blank.(DCSG00548034 -Fixed: updated Build script to change permissions of different file types.(DCSG00776044 -LSA is not allowing user to create more than 2 VDs.(DCSG00726030 -Handle the new event LD_ERASE_POTENTIAL_LEAKAGE in client.(DCSG00776413 -Fixed: enclosure state is to be shown need attention when it is in fault state.(DCSG00965622 -Ventura_LSA_7.17: LSA still displays background processes of VDs(VD init) post clear config from LSA.(DCSG00644476 -Ventura_LSA_7.17: LSA crashes on creating 64th VD.(DCSG00708134 -Warning removal as part of new gcc upgrade..(DCSG00757533 -Fixed: Changing Resource type displays recover option.(DCSG00411317 -Ventura_LSA_7.17: Event ID: 633 is generated on changing VD policy when expansion is in progress.(DCSG00650740 -LSA MR 7.17: LSA has older version of LSA_Lib_Utils packaged..(DCSG00397682 -WG: Power supply details are not shown on clicking "No of Power Supplies" in enclosure properties.(DCSG00544568 -LSA MR 7.17 : When partially degraded VD erase is in progress, Erase option is available in Elements Action instead of Stop Erase.(DCSG00758642 -Fixed: Added security flags to make file to build secure LSA binaries.(DCSG00813569 -Legacy:LSA MR 7.17: Upon clicking on the hostname(administrator/root )drop down for the second time, Remote Server discovery option appears twice..(DCSG00396896 -Fixed: Added security flags to LSA Makefile.(DCSG00814604 -WG: VMware user able to download LSA logs of gateway.(DCSG00384359 -Fixed: added directory wise permission while creating corpus.(DCSG00543670 -WG: Server ID cookie generated after login has "httponly", "secure" and "sameSite" fields empty for RWC3 installation.(DCSG00547995 -LSA Client WG: Power supply details are not shown on clicking "No of Power Supplies" in enclosure properties.(DCSG00549353 -LSAServer - WG: Redhat OS icon shown for OpenEuler OS in remote discovery page and Manual discovery page.(DCSG00735182 -WG: Redhat OS icon shown for OpenEuler OS in remote discovery page and Manual discovery page.(DCSG00652676 -Ventura_LSAMR_7.17:VD initialization progress is displayed on triggering VD expansion..(DCSG00776513 -WG 7.17 PA2: error token 009" seen when LSA downgrade is performed from 7.17 PA2 to 7.16 RC build and complete LSA uninstallation is not successful.(DCSG00434242 -Ventura_LSAMR_7.17: Background process displays previous status information post clear config.(DCSG00830097 -WG: LSA allows providing same Busy port to both Webserver and LSA port, ultimately LSA service fails to start.(DCSG00556924 -LSA MR 7.17: In RLM page After applying/clearing filter, Add Physical drive tab is enabled even though no drives are selected..(DCSG00649177 -LSA shows stale data and failed to refresh topology until LSA service restart.(DCSG00477447 (Port Of Defect DCSG00708193) -Fixed: state-change isn't updating state of the PD incase of bad to good.(DCSG00834219 (Port Of Defect DCSG00916906) -LSA : While updating UEFI for 440-16e (Aero-IT), "Image update failed" message is coming and next time it passes.(DCSG00935787 (Port Of Defect DCSG00937166) -LSA Common: Stale folders still persist in html folder.(DCSG00388225 (Port Of Defect DCSG00394666) -Fixed: Limit R1 from R6 migration, show when applicable.(DCSG00776529 (Port Of Defect DCSG00960423) -Fixed: modify virtual drive to show appropriate allowed operation values.(DCSG00433726 (Port Of Defect DCSG00518957) -WG: Server ID cookie generated after login has "httponly", "secure" and "sameSite" fields empty for RWC3 installation.(DCSG00547995 (Port Of Defect DCSG00654119) -LSA : PDs are not listing properly after pull/push from enclosure/Backplane.(DCSG00916164 (Port Of Defect DCSG00917749) -change button is not enabled for Behavior params change.(DCSG00426709 (Port Of Defect DCSG00428813) -LSA : PDs are not listing properly after pull/push from enclosure/Backplane.(DCSG00916164 (Port Of Defect DCSG00917716) -Fixed: StateChange Event handled to update repository.(DCSG00555478 (Port Of Defect DCSG00708165) -Fixed: Corrupt image file leads to LSA crash.(DCSG00951718 (Port Of Defect DCSG00960390) -LSA displays all lane speed values under Manage PCIe storage interface.(DCSG00547375 (Port Of Defect DCSG00549936) -Fixed: Parameter 16GT is not visible while updating lane speed.(DCSG00255550 (Port Of Defect DCSG00960305) -LSA MR 7.18: LSA events shows full description of the behavior mode(Jbod) change instead of mentioning Mode name..(DCSG00913588 (Port Of Defect DCSG00960083) -LSA allows to upgrade without uninstalling previous version of LSA in Ubuntu 18.04.05.(DCSG00435199 (Port Of Defect DCSG00500750) Headline:.(DCSG00965622 (Port Of Defect DCSG00980121) -LSA : RHEL 7.9 , Ubuntu 18.04.5 and ESXi7.0u1 OS are missing in Linux LSA readme file & ESXi7.0u1 OS is missing in Windows LSA Readme file.(DCSG00421344 (Port Of Defect DCSG00506913) -PH19 Alpha - LSA - HBA listed with incorrect index order under view server profile.(DCSG00930402 (Port Of Defect DCSG00960246) -LSA Windows installation from CDROM fails - error opening installation log file.(DCSG00944480 (Port Of Defect DCSG00944695) -Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00501331) -Shenandoah_MRSA:Enclosure Location and Status coming as Unknown in MRSA when Click to download all the Enclosure or Backplane properties.(DCSG00412122 (Port Of Defect DCSG00414363) -VenturaLSA_7_18: Unable to trigger Fast initialization on VDs.(DCSG00959286 (Port Of Defect DCSG00960876) -Set PR properties are showing offline VDs and user is able to add those offline VDs for Patrol read operation.(DCSG00906763 (Port Of Defect DCSG00919131) -Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys.(DCSG00423048 (Port Of Defect DCSG00495341) -LSA : "Unlock" button is not getting enabled if user copy & paste the LKMS passphrase in the security key text box.(DCSG00923594 (Port Of Defect DCSG00925032) -21B- LSA allows EKM to LKM migartion & ask for Authentication key.(DCSG00920215 (Port Of Defect DCSG00925030) -Shenandoah_MRSA : OLH link for MRSA OEM build refers to screenshots of non-OEM build.(DCSG00501038 (Port Of Defect DCSG00519848) -Aero MR : LSA Channel: Drive connector information not displayed correctly when compared with Storcli output.(DCSG00416118 (Port Of Defect DCSG00416248) -LSA: PD insertion event display issue.(DCSG00840938 (Port Of Defect DCSG00916909) -Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys.(DCSG00420399 (Port Of Defect DCSG00421316) -LSA services not starting after installing LSA on RHEL 8.3.(DCSG00915932 (Port Of Defect DCSG00916838) -LSA Server: Code refresh based on Security Tool findings.(DCSG00500569 (Port Of Defect DCSG00501486) -LSA : Manage SAS Storage Link Speed is setting values only for 2 phys out of 4 phys if user sets it from LSA.(DCSG00916870 (Port Of Defect DCSG00944446) -Fixed: state-change isn't updating state of the PD incase of bad to good.(DCSG00834219 (Port Of Defect DCSG00916893) -LSA : Enable/Disable SSD caching is not working for all VDs at once if user selected multiple VDs and enabling/disabling SSD cache.(DCSG00409275 (Port Of Defect DCSG00415053) -LSA MR 7.18: Click to download option is enabled in Download snapdump page, eventhough no files are selected for download..(DCSG00922702 (Port Of Defect DCSG00960272) -Fixed: Added security flags to LSA Makefile.(DCSG00814604 (Port Of Defect DCSG00816013) -LSA cursor is actively cycling after failed to import the max (240Lds) LDs reached.(DCSG00921402 (Port Of Defect DCSG00922051) -Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00501332) -Addition of 3rd party licenses into the package.(DCSG00501027 (Port Of Defect DCSG00554176) -LSA : Loopback IP address is not coming after restarting LSA service if there is no LAN/NIC card.(DCSG00417564 (Port Of Defect DCSG00421192) -WG: login to manage server page with readonly access and then login to any VMware system, logout to VMware grants readonly user "Admin" previlige.(DCSG00384343 (Port Of Defect DCSG00401650) EnhancementRequest: -Apps Advanced Security Enhancements and updates - part 2.(DCSG00388186 -LSA: Add Event for possibility of incomplete writes on parity VDs with no battery backup (ER: DCSG00229751).(DCSG00735186 -Implimented: TCP/HTTP Fortification.(DCSG00436245 -Enable end user tools to read custom SN.(DCSG00938513 -Aero-Margay Connectivity Solution Integration - MR API.(DCSG00956233 -Apps Advanced Security Enhancements and updates - part 2.(DCSG00394652 -Implimented: Additional error code handled.(DCSG00310385 -update dependent to comply with latest OS support.(DCSG00428823 -Upgradation of dependent component with security flags.(DCSG00427912 -Request IT read Product Name/Model Number for SATA drives so that the Product Name/Model Number is displayed in full + FW Version.(DCSG00371060 -Added support for RHEL 8.3.(DCSG00373404 -Apps Advanced Security Enhancements and updates - part 2.(DCSG00388184 -Upgrade of OpenSLL and its dependent components.(DCSG00404741 -LSA: Short term solution for handling SES cable missing to Atlas.(DCSG00735187 -Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596 -Add OpenEuler OS (20.03 LTS) support on Kunpeng 920 Gen4 ARM for Ventura MR/iMR (Driver Binary, StorCLI, Storelib, LSA).(DCSG00546575 -Apps Advanced Security Enhancements and updates - part 2.(DCSG00388185 -MegaAPI: Add API changes for temporary key escrow (PR: DCSG00428069).(DCSG00935525 -Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00937396) -Apps Advanced Security Enhancements and updates - part 2.(DCSG00388184 (Port Of EnhancementRequest DCSG00394003) Headline:.(DCSG00427912 (Port Of EnhancementRequest DCSG00432022) Headline:.(DCSG00427912 (Port Of EnhancementRequest DCSG00431998) -Linux: LSA service script improvement.(DCSG00841007 (Port Of EnhancementRequest DCSG00903463) Headline:.(DCSG00404741 (Port Of EnhancementRequest DCSG00427334) -Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596 (Port Of EnhancementRequest DCSG00553614) -Apps Advanced Security Enhancements and updates - part 2.(DCSG00394652 (Port Of EnhancementRequest DCSG00447326) -Update 3rdpartyComponents with latest security flags and review deprecated APIs.(DCSG00553596 (Port Of EnhancementRequest DCSG00654068) -LSA: Linux 32 bit binary removal.(DCSG00221416 (Port Of EnhancementRequest DCSG00408188) -Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00941433) -Implimented: TCP/HTTP Fortification.(DCSG00436245 (Port Of EnhancementRequest DCSG00937397) -Added support for RHEL 8.3.(DCSG00373404 (Port Of EnhancementRequest DCSG00428725) 007.016.021.000 - Moderate Impact --------------- Defects: -LSA : While updating UEFI for 440-16e (Aero-IT), "Image update failed" message is coming and next time it passes.(DCSG00935787) Enhancements: -Update comment for SL_ERR_IR_INVALID_FW_FLASH_IMAGE_NVDATA.(DCSG00936705) 007.016.015.000 - Moderate Impact --------------- MR 7.16 Defects: -Instance validation fails for Manage Server GET (MR 7.14, 7.014.000.000): Schema 32(DCSG00079899) -LSA 7.15 WG: "Replace Missing drive" page will not open after clicking and closing "Assign Dedicated hotspare" page.(DCSG00167347) -LSA MR 7.16: While Updating the firmware Selected Firmware Version is showing wrong text instead of Firmware Version.(DCSG00359474) -LSA WG : Uninstall instructions mentioned in LSA ESXi readme is wrong.(DCSG00126899) -LSA 7.14 : Clicking on "Configure" option from server landing page is redirecting to controller info page instead of Advanced config page.(DCSG00125950) -Physical drive Serial number info should be populate in LSA(DCSG00321940) -Legacy:WG 7.14 PA2: Unconfigured Bad drive count is not updated for Drive tab when Vds are created.(DCSG00092875) -WG: Folder structure remains after uninstalling the direct agent on windows(DCSG00347401) -WG: RWC3 Ubuntu Linux build (07.016.003.000)loads with http instead of https(DCSG00384392) -Fixed: Clear staging directory to allow new downloads(DCSG00127783) -Description of the behavior of the "fast initialization" on RWC3 is inaccurate (Intel re-branded LSI Storage Authority/LSA)(DCSG00263417) -Current speed under "Manage PCIe storage interface" is showing like 2.5GT, 5GT, 8GT instead of 2.5GT/s, 5GT/s, 8GT/s(DCSG00301958) -WG 7.14: Invalid VD capacity displayed while creating AddVD on a hole with invalid number of VDs(DCSG00080851) -Select all checkbox needs to be consistent in all the tabs(DCSG00108298) -LSA-Missing rebuild when a drive goes offline by physical removal(DCSG00327294) -Fixed: check spdm support bit before populating details(DCSG00108070) -Aero : MR 7.16 -Channel: Mismatch between LSA and Storcli output for drive firmware version(DCSG00342645) -Update the PD size for higher size 4k Drives(DCSG00395158) -Fixed: Security node is being populated for non secure drives(DCSG00140174) -LSA MR 7.16: Sorting is not available in "JBOD to Unconfigured Good conversion" page.(DCSG00311369) -Enable Drive Security has incorrect phrase and incorrect word. Forcing a Offline PD, confirmation message shows incorrect word.(DCSG00358750) -MR 7.16 : Aero Channel : LSA: "Virtual Drives" should be printed for message event id= 195 instead of logical drives(DCSG00316205) -LSA WG: Wrong tool tip is seen on Apply button, while filtering the drives.(DCSG00074726) -reference to Virtual Drive instead of Logical Drive in ReadMe(DCSG00111540) -Fixed: secure discovery handling(DCSG00318199) -LSA WG: Help(?) icon present in LWA in "Schedule Consistency check" page.(DCSG00129159) -LSA WG 7.15 : Add hotspare option is enabled for spanned raid levels, even after creating VD.(DCSG00226412) -Fixed: Import certificate with Seal is not working, Seal is not enabled after import.(DCSG00122476) -fixed: update switch to be displayed as managed switch(DCSG00140169) -LSA WG: LSA is allowing to add virtual drives more than 16, when spandepth is increased/decreased.(DCSG00084397) -Voltage sensor values are shown in negative for atlas board(DCSG00151544) -LSA Client: Behavior mode parameters is not shown(DCSG00079966) -LSA: While creating 64 slice VD on same DG the 10th VD Name creating as VDName_010 instead of VDName_10(DCSG00253718) -WG 7.14 : in AERO IT controller, the enclosure serial number is shown blank, Storcli shows NA(DCSG00138884) -Legacy: LSA WG: LSA is allowing to change the personality mode of the controller in Non-admin access.(DCSG00083219) -WG: no status code is displayed on failure of "start recover" operation(DCSG00105107) -LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings(DCSG00134600) -WG 7.14: In Physical Drive properties, Multipath field is showing "Yes" for all the drives attached, eventhough drives are not in Mulitpath configuration.(DCSG00092819) -7.14 LSA : Update the LSA readme.(DCSG00108916) -WG: LSA Does not have filter button in drives tab for IT controller Controller console page(DCSG00138885) -LSA MR 7.16: Sorting is not working after clicking on Filter option in RLM page.(DCSG00359695) -LSA MR 7.16: Modify Virtual Drive field is disabled after changing the unit value from GB to MB.(DCSG00345377) -WG: Instance Validation failed for event History get,( MR 7.14, 7.014.004.000): MR Ventura: JBOD mode(DCSG00129472) -LSA 7.15 WG: "Make JBOD" option is available for the drives which are Prepared for removal.(DCSG00212830) -VD Read cache policy displayed wrong as RA , whereas detailed VD policy shows correct(DCSG00148244) -MR 7.16 :Channel_ LSA: VD property modification ( WT to AWB) event description not in sync with the actual VD property(DCSG00323028) -fixed: Recovery of NVME drives(DCSG00104462) -WG: Creation of simple configuration with dedicated hotspare, LSA creation notification does not include hotspare in total PDs used in config creation(DCSG00259092) -LSA MR 7.15: Add Virtual Drive field is enabled and VD is added for patrol read, even after unselecting all VDs in Set Patrol read page.(DCSG00228853) -In server settings page under email tab, in absence of any email id, Test configurartion should be disabled(DCSG00146660) -WG: Selected element minor GUI issue in naming convention, LSA continues to show download in progress continuously(DCSG00151401) -MR 7.16 : LSA: Logical ID of enclosure is not displayed correctly(DCSG00316050) -LSA 7.14: Set adjustable task rate field is not allowing to save the changes.(DCSG00126266) -LSA Client : Handle Manual Discovery failure cases(DCSG00098052) -Manage PCIE Storage interface does not show any data.(DCSG00340896) -Enclosure Location and Status coming as Unknown when Click to download all the Enclosure or Backplane properties(DCSG00412122) -Silent installation with default Web server port and default LSA port is failing.(DCSG00092962) -LSA MR 7.16: Number of VDs is not getting updated after deleting the first created VD.(DCSG00361755) -When selected 6272 KB firmware for update failure seen with message as file is more than 16MB size(DCSG00080838) -LSA Conf: Clean and remove unused fields(DCSG00297566) - -WG 7.14 : VD expansion more than 100 % is allowed in LSA(DCSG00126745) -"The given port is in use the next available port " message seen During every DA installation(DCSG00412121) -LSA MR : Replace Missing drive option is available for Non-admin privileges.(DCSG00298090) -WG: login to manage server page with readonly access and then login to any VMware system, logout to VMware grants readonly user "Admin" previlige(DCSG00384343) -LSA MR 7.16 :Progress bar is not shown for Rebuild and Patrol read operations for Non-admin privileges.(DCSG00347097) -WG: Instance Validation failed for Controllers get,( MR 7.14, 7.014.004.000)(DCSG00129470) -for IT Controller update firmware radio buttons and text does not have clickable hand icon(DCSG00138887) -Fixed: Added remove files after files are zipped for snap dump download(DCSG00085869) -Enclosure location coming as "unknown" for UBM3 if you boot the system without any drives connected(DCSG00081762) -LSA: Filter options does not list NVMe drives in PD list of controller console page(DCSG00138709) -LSA: Modifying VD properties during Multiple VD creation list the VD name as "VDName_00" instead of VDName & Modify VD page does not have hand symbol for help icon(DCSG00354486) -LSA7.16_Linux compiler specific changes(DCSG00340258) -Non-interactive/silent installation does not have options to install LSA based on EVENT NOTIFICATION CHOCIES.(DCSG00078199) -WG MR 7.14 PA: Clear option grayed for an incomplete foreign configuration(DCSG00085818) -Version not reflected correctly when we upgrade MRSA in ubuntu(DCSG00404727) -In Set patrol read properties page, Unselected VD is also added for Patrol read.(DCSG00259156) -LSA read me: Update the Open Source details(DCSG00353259) -updation of libfcgi.dll with DYNAMICBASE flag(DCSG00426989) -Change button is enabled when no change performed in Change Behavior Mode(DCSG00382779) -MR 7.14 PA2: Rescan Under foreign config menu is grayed out after importing foreign Vd.(DCSG00101341) -LSA does not display full message, while making an offline drive online of a VD from Server Landing Page.(DCSG00366127) -Fixed: lib utils version update(DCSG00360539) -LSA uninstallation is failing on HPE(DCSG00164985) -VDs of different capacities(MB/GB) is not sorting properly.(DCSG00080102) -Cisco M6: Selecting drive after filter is applied Element selection is shown as "Zero".(DCSG00278212) -API clarification for large io support(DCSG00307042) -WG 7.14 PA2: 'show password' and 'show key' are active for "Pause for password at boot time" under 'change drive security'.(DCSG00108259) -WG: making an offline drive online of a VD from server summary page, LSA does not notify regarding the destructive operation.(DCSG00340323) -RWC3 windows build (07.014.004.000)loads with http instead of https(DCSG00125606) -Shenandoah_MRSA:Error message not proper for Ubad to UGood for a Bad drive(DCSG00092851) -LSA WG: Alignment issue in Manage server page.(DCSG00138055) -RWC3 windows Header has LSA Storage Authority as product name instead of RAID Web Console 3.(DCSG00125329) -Fixed: Added code to change content type which is acceptable to IE(DCSG00138898) -LSA MR 7.15 Alpha: Clicking on "modify" icon will enable the Add Virtual Drive field even after creating a VD of full size(DCSG00293914) -fixed: changed unit to Byte in case of zero size drives(DCSG00072680) -LSA Windows: Usage of nginx 1.18 version which is a stable version(DCSG00324413) -Fixed:SPDM configuration page shows as blank In LSA(DCSG00138574) -Legacy : LSA WG 7.14: Remove Manage server icon is not placed properly for Manually added ESXi servers in List view.(DCSG00110210) -MR 7.16 :Channel_ LSA: Missing warning message when tried to modify PCIe Storage Interface(DCSG00358742) -Use NVRAM to save PTB information -- API changes(DCSG00082981) -When heavy IOs active, LSA is taking very long time to download server report .(DCSG00092899) -MRSA Desktop icon should not be present for Ubuntu as per the Read me(DCSG00099517) -WG 7.14 PA2: LSA installation on Ubuntu, fails with error "LSA_lib_utils" : Gateway can not be launched(DCSG00089795) -Manage server page throws error message "400:" for invalid credentials.(DCSG00136334) -WG 7.14 PA2: Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 7.8(DCSG00092841) -WG: LSA fails to create Drive group for Non-span depth supported Raid volumes.(DCSG00089810) -x Readme needs some modification on supported OS and reference as MRSA in some places(DCSG00146624) -WG: Sorting is not working as expected in drives tab with multiple spans. with a span having a missing drive(DCSG00341095) -LSA Windows x64: Some of the OS is having an issue(DCSG00307418) -LSA MR 7.16: Sorting based on Drivegroup is not proper in Assign dedicated hotspare page.(DCSG00322767) -Launchpad on desktop of Rhel 7.7 is shown as "LaunchLSA" instead of "LaunchMRSA"(DCSG00072655) -LSA shows FW update failure message even after FW update is successfull.(DCSG00082492) -LSA 7.15 WG: Sorting based on Drive group capacity is not proper in "Assign Dedicated hot spare" page.(DCSG00166089) -Update credits files in client credits(DCSG00353889) -Shenandoah_MRSA:Event description blank for 628,629 in MRSA(DCSG00325879) -Fixed: Monitor Conf files are missing write permission(DCSG00129770) -Fixed: Spanned drive min vd check calculation error(DCSG00138063) -Update Credits.html with updated licenses(DCSG00428654) -LSA MR 7.15 : LSA does not show message while modifying Disk cache policy of VD in Advanced configuration page.(DCSG00263699) -Upgrade is not working in ubuntu from 7.15 to 7.16 packages(DCSG00315134) -LSA : Loopback IP address is not coming after restarting LSA service if there is no LAN/NIC card(DCSG00417564) -MR controller with No Alram is not auto refreshing on changing the controller properties(DCSG00124484) -On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04(DCSG00105871) -displays 0 Needs attention when we have degraded LDs(DCSG00092831) -WG 7.14 : Mismatch seen in the total number of available UG drives and actual no of PDs in PD list during encrypted R60 VD creation.(DCSG00134663) -LSA - Set PR properties is showing VD as optimal though it is offline or degraded(DCSG00226300) -Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2(DCSG00115253) -Fixed: updated Readme with "Health status shown in LSA is as per LSA's health algorithm."(DCSG00412125) -LSA MR 7.16: Changing the lane speed in Manage PCIe storage interface page is showing Operation is either not allowed or not supported, whereas storcli shows Success reboot required(DCSG00397804) -WG: ""Your connection is not Private" shown twice in "Manage server page"(DCSG00391486) -Legacy : WG: LSA auto logs in on clicking "verify" button for "Managed" VMware manually added server in managed server page(DCSG00112178) -Fixed: updated nginx and libcurl(DCSG00414394) -WG: Sorting does not work in Span tab of VD in presence of missing drive(DCSG00258267) -Fixed: Build script changes to pick up the latest conf and ini files(DCSG00125997) -SSD WearGuage Estimated Life Remaining in Percent as "N/A" for New Drives(DCSG00074664 -Fixed: Certificate Algorithm details are showing blank for few certificate slots.(DCSG00123069) -LSA fails to import R0 which has pinned cache after a reboot(DCSG00356398) -WG: instance validation failed for controllers Operations GET: iMR Ventura : Schema 34: MR 7.16(DCSG00342339) -LSA service fails to start when LSA port value is set to 2463(DCSG00083383) -Secured foreign locked VDs details are not displayed under foreign configuration to import/clear foreign config(DCSG00103239) -LSA Server: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00114253) -Fixed: Invalidate certificate slot is failing with error code 165.(DCSG00122448) -LSA WG: Non-span depth supported raid levels are showing "Span depth modify" option in Advanced config page upon clicking on "Compare and select" link.(DCSG00143503) -LSA MR 7.15 Alpha: Changing the number of spans while creating DG shows wrong info about the Number of VDs can be added to DG.(DCSG00264033) -LWA Compilation Issue Resolution(DCSG00228825) -Only the text in "Start recover" operation for bad NVMe drive is clickable(both CC and ss Page), GUI issue on expanding the controller health(DCSG00105108) -LSA WG: In Advanced configuration page, hotspare PD adding page disappears when users scrolls up/down the LSA page.(DCSG00080074) -MR7.15 LSA Client: Unsupported icon in Server and Controller Dashboard(DCSG00277830) -WG: No success or failure icon is shown on silencing alarm, hand symbol is not present for close icons in advanced enclosure properties(DCSG00255201) -WG: nginx conf file after installing DA is empty. unable to manage the DA from Gateway though DA LSA service running(DCSG00383999) -Clear configuration is success when JBOD has OS(DCSG00382535) -LSA Server: Hard coded string over disk and controller implementation(DCSG00152933) -Enclosure Name not correct for x4 Backplanes Connected via Straight cables to two controllers.(DCSG00315377) -WG: Instance Validation failed for servers get,( MR 7.14, 7.014.004.000)(DCSG00129468) -PH15 LSA IT:In RHEL7.8 for enclosure drives Multi path field is showing as"Yes" In Physical Drive properties,without Multipath configuration(DCSG00132726) -Shenandoah: MRSA: VD reference in modify LD property ( try to change disk cache and the help balloon refers to VD)(DCSG00324759) -SPDM_LSA : There is no successful message displayed for the export CSR action.(DCSG00122457) -Memory Leak issues LSA Build(DCSG00149688) -Port Box Bay info incorrect for ISE operation page(DCSG00092895) -The "More Actions" menu doesn't open up when the RAID controller is ESRT2(DCSG00259353) -Enclosure Bay count coming Wrong in(DCSG00074661) -Updated Arm read me file with arm specific changes(DCSG00085797) -LSA Property: package version mismatch between components in IT(DCSG00307461) -Test Configuration button should be disabled till we get the response(DCSG00299771) -LSA Client: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00129756) -LSA MR 7.16: Not able to modify the VD size in Advanced configuration page.(DCSG00381677) -multi-LUN tool support for multi-actuator drives.(DCSG00122386) -Shenandoah_MRSA : Number of hours is wrong in MRSA evetns for Event 544(DCSG00325891) -LSA Client: Manage Link Speed not showing the error message(DCSG00310339) -Manual Discovery failure shouldn't return HTTP status:200(DCSG00098024) -LSA Common: Package 64 bit monitor libraries as part of Windows x64 package(DCSG00307031) -Shenandoah_MRSA: Enclosure Type in Server profile is not complete. Needs to allign with CLI(DCSG00081768) -LSA: MR-7.14-SPDM tab needs correction.(DCSG00108295) -LSA: "Incorrect Connector Name" under physical drive properties.(DCSG00358747) -LSA Common: Stale folders still persist in html folder(DCSG00388225) -fixed: import of certificate issue(DCSG00094369) -Not able to launch MRSA though the launch icon or installer(DCSG00078194) -LSA MR 7.15 Alpha : Schedule consistency Check field is showing partially degraded VD as optimal.(DCSG00263547) -Event strings not proper in MRSA for 379,383,385(DCSG00325883) -Junk characters are getting displayed in enclosure information with no drives connected.(DCSG00074730) -LSA MR 7.16: Filter option is not working properly in RLM page.(DCSG00342455) -PCI-Switch subtype when enclosure is an pci-switch(DCSG00085935) -Predicitive Failure count and Drive temperature not getting updated in PD property page(DCSG00082823) -Windows OS crashes after upgrading to LSA 007.014.005.000(DCSG00138044) -Shenandoah_MRSA: Controller Drop down not listing all controllers(DCSG00108923) -LSA - ICX - Lane speed under Manage PCIe storage interface is showing like 2.5GT, 5GT, 8GT instead of 2.5GT/s, 5GT/s, 8GT/s(DCSG00259499) -fixed: Min VD size check for R1 was missing(DCSG00086324) -fixed: MFI code stops LSA from showing slot 0 and 1 when it is not configured(DCSG00123067 -WG 7.14 PA:During the Creation of r60 vd , removal/adding drives creates inconsistency in AddPhysicalDrive and Addhotspare tables.(DCSG00079935) -"Compare and Select" page shows Raid 6 with 3 drives(DCSG00087244) -Current speed under "Manage SAS storage link speed" is showing like 3Gb, 6Gb, 12Gb instead of 3Gb/s, 6Gb/s, 12Gb/s(DCSG00301640) -Drives connected to IT controller reports Shield Counter(DCSG00264740) -WG: RWC3 windows build loads with http, instead of https(DCSG00340881) -WG 7.14 PA2: Stripe size under DG does not sort properly when multiple Vds are created with different strip sizes.(DCSG00093774) -LSA_SPDM : Import certificate chain event id 622 description is not proper.(DCSG00122482) -WG MR 7.14 PA1: LSA allows to select 512B drives as DHSP for 4K DG(DCSG00078853) -Backplane info is not proper in expanded state(DCSG00106485) -Shenandoah_MRSA : Transport feature needs to be removed from array properties(DCSG00081965) -Fixed: update approved user list(DCSG00384488) -Fixed: Import certificate /Download CSR options are disabled for slot 0 & 1(DCSG00138892) -Aero MR : LSA Channel: Drive connector information not displayed correctly when compared with Storcli output(DCSG00416118) -Fixed: changed values to comply with schema restrictions(DCSG00140179) -LSA WG : LSA "Download Diagonstic" field is not downloading the ttylog in Readonly access.(DCSG00083816) -LSA - Error code 169 - Description Shows as Blank.(DCSG00111872) -Credits page needs an update(DCSG00232932) -WG:LWA:Not all snapdump logs are downloaded on trying to download all the generated snapdump logs(DCSG00216125) -MR 7.16 Aero: Storcli displays Enclosure Serial Number as blank whereas LSA shows as "N/A"(DCSG00316066) -Fixed: permission of only last node in path was changing(DCSG00384372) -After the upgrade or trying to delete through RPM launch Icon is not deleted(DCSG00078205) -Fixed: issue resolution message for non-recoverable drive(DCSG00105032) -Port information is wrong when SAS drive is connected to UBM3 BP with 416A controller(DCSG00316863) -Fixed: enclosure type and subtype display changes for PCI-switch(DCSG00314948) -Remove the individual elements download from MRSA(DCSG00418470) -WG: LSA does not allow to change to any other behavior once encountering error during behavior change : GUI Change(DCSG00255157) -MR 7.15: LSA fails to launch in Ubuntu.(DCSG00221326) -JBOD creation is not allowed through MRSA both on windows and Linux on 7.16 builds(DCSG00317915) -Shenandoah_MRSA:Enclosure type not correct for UBM4 backplanes in server profile(DCSG00360535) -WG MR 7.16 : Direct agent and standalone does not load on Ubuntu ARM system.(DCSG00395624) -Spacing issues on securing a DG as secure, minor GUI issue non notification of enabling scsiUnmap(DCSG00138886) -Unable to uninstall the RWC3 on Ubuntu 20.4 when xterm present(DCSG00146748) -WG 7.14:During VD creation filtering 4k drives displays blank PD table when mixing is not allowed(DCSG00078974) -WG 7.14 PA2: "Unlock" button should be grayed out for Foreign secured locked PD.(DCSG00094756) -LSA MR 7.16: Inconsistency while upgrading the LSA.(DCSG00417467) -Shenandoah_MRSA: Virtual disk reference in " Make Drive Online" option(DCSG00306847) -LSA MR 7.15: Not able to remove the manually added servers.(DCSG00239878) -Legacy: LSA WG: In home page, Scroll up option is missing when user expands the Server profile.(DCSG00083860) -MR Controller Downloaded Diagnostic Data has Deviceid set to 0 in line number 12(DCSG00125594) -fixed: R1 migration form R0 with one UG-good PD(DCSG00312113) -WG: RWC3 Ubuntu Linux build shows LSA instead of RWC3 during installation.(DCSG00385902) -Foreign import config shows "Incomplete or non-importable foreign config" for secured VD after unlocking with proper keys(DCSG00420399) -LSA MR 7.16: VD is expanded to 100%, when user provide the expansion percentage value between 0.1 to 0.5(DCSG00303650) -Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down(DCSG00080854) -Uninstall the RWC3 does not remove the complete folder structure(DCSG00125612) -WG: empty enclosure ID and slot ID is displayed for NVMe initialization event in event logs(DCSG00105113) -SAS address is shown for PCIe (NVME) drives instead of WWID(DCSG00138744) -Health status changes of the remote server does not get updated in the gateway remote discovery page(DCSG00086628) -Shenandoah: MRSA events for enclosure insertion not in sync with firmware logs(DCSG00303613) -LSA is showing wrong "LSA_lib_utils" version while uninstalling in linux.(DCSG00083760) -WG 7.14 PA2:managed server icon for self server is shown "add" in manage server page if we add ubuntu/ any server to manage server list.(DCSG00112829) -WG: Instance validation fails for Configuration service GET, LSA build : MR 7.14, 7.014.000.000(DCSG00079959) -LSA MR 7.15: Reload option should not be available in Remote discovery page.(DCSG00235388) -Shenandoah: MRSA: keyType information wrong in MRSA for event 343(DCSG00333167) -Whitley ICX : LSA - Add physical drives option is not coming for user when trying to recon from R6 to R0(DCSG00104470 (Port Of Defect DCSG00105105) -7.14: Update read me files(DCSG00221381 (Port Of Defect DCSG00226031) -Handling Manual Discovery ADD case(DCSG00077625 (Port Of Defect DCSG00101928) -behavior mode values is not being set properly(DCSG00426348 (Port Of Defect DCSG00426351) -AV_RAID_MODE:Missing drive info not displayed when performed on PDs of multiple DGs(DCSG00411847 (Port Of Defect DCSG00415015) -LSA_Server: Mismatch in "disk cache policy" during VD creation and after VD creation(DCSG00404783 (Port Of Defect DCSG00408997) -LSA uninstallation is failing on HPE(DCSG00164985 (Port Of Defect DCSG00164991) -"delete config" command clears the config, when OS/FS in the drive without "force" option.(DCSG00077464 (Port Of Defect DCSG00101933) -WG: Instance validation fails for PHY's GET and phy/0 GET (MR 7.13, 7.013.004.000)(DCSG00066942 (Port Of Defect DCSG00078972) -CSET Port of Defect DCSG00078494: Lone LF in body of email message(DCSG00078494 (Port Of Defect DCSG00078973) -Connected device under "Manage PCIe storage interface" is not showing any NVMe drive details(DCSG00302010 (Port Of Defect DCSG00314950) -Fixed: updated configured PD to include offline and failed drives(DCSG00382593 (Port Of Defect DCSG00404817) -WG: Manually added VMware server continues to show and does not get auto discovered.(DCSG00243976 (Port Of Defect DCSG00312021) -LSA : Modify properties option is not coming to user for CC VD using 730-8i controller(DCSG00408495 (Port Of Defect DCSG00415046) -Fixed: Parameter 16GT is not visible while updating lane speed(DCSG00255550 (Port Of Defect DCSG00421350) -LSA Server: Manual discovery fix(DCSG00246091 (Port Of Defect DCSG00312023) -WG: VMware user able to download LSA logs of gateway(DCSG00384359 (Port Of Defect DCSG00395338) -LSA Conf: Clean and remove unused fields(DCSG00297566 (Port Of Defect DCSG00347725) -On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04(DCSG00105871 (Port Of Defect DCSG00137404) -update HBA 440-16i UEFI BSD failed via LSA(DCSG00074275 (Port Of Defect DCSG00101747) -LSA Client: Manage Link Speed not showing the error message(DCSG00310339 (Port Of Defect DCSG00310340) -Changing the ngroups list values(DCSG00102619 (Port Of Defect DCSG00103258) -LSA Property: package version mismatch between components in IT(DCSG00307419 (Port Of Defect DCSG00312026) -LSA Client: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state(DCSG00129756 (Port Of Defect DCSG00152277) -LSA_Avenger: Modify VD properties page is not opening, when VD is created from Simple configuration.(DCSG00337910 (Port Of Defect DCSG00345130) -LSA Avenger: Sorting based on VD capacity is not working when VD with size more than 1 TB is present in DG(DCSG00321981 (Port Of Defect DCSG00335909) -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0(DCSG00063716 (Port Of Defect DCSG00065591) -LSA_Avenger: filtering and then sorting drives which are used in vd creation , drives table goes blank.(DCSG00354629 (Port Of Defect DCSG00363767) -LSA : Enable/Disable SSD caching is not working for all VDs at once if user selected multiple VDs and enabling/disabling SSD cache(DCSG00409275 (Port Of Defect DCSG00415052) -LSA report Power supply status only after LSA service restart(DCSG00086465 (Port Of Defect DCSG00102025) -PH15 LSA IT:In RHEL7.8 for enclosure drives Multi path field is showing as"Yes" In Physical Drive properties,without Multipath configuration(DCSG00132726 (Port Of Defect DCSG00138842) -MR7.15 Alpha (DBU) WG: unable to change the behavior mode to "none" on Aero controller(DCSG00278399 (Port Of Defect DCSG00312025) -CSET Port of Defect DCSG00355995: LSA imports all foreign configs while importing 240VDs, but it shows error message "The server could not import foreign configurations" (Error Code:2)(DCSG00355995 (Port Of Defect DCSG00395255) -Cisco - CSCvv26000: C240 M6 : Improper display of RAID5 VD size while creating VD through LSA in Zuma beach(DCSG00313412 (Port Of Defect DCSG00325945) -LSA- ICX : Profile properties shows that WB volumes support as "False" under controller Info(DCSG00254886 (Port Of Defect DCSG00278008) -MR 7.15 - LSA Event Log is showing Default Read Policy as Always Read Ahead ...needed to be "Read Ahead" instead(DCSG00299006 (Port Of Defect DCSG00307816) -Fixed: updated nginx and libcurl(DCSG00414394 (Port Of Defect DCSG00419679) -Shenandoah_MRSA: Controller Drop down not listing all controllers(DCSG00108923 (Port Of Defect DCSG00110220) -LSA Client : Handle Manual Discovery failure cases(DCSG00098052 (Port Of Defect DCSG00112023) -ICX_Whitley_Orion: LSA- Link speed details are not showing properly for Tape drive in WebGUI(DCSG00075777 (Port Of Defect DCSG00102597) -Manual discovery page gets hung while adding the server to Auto discovery list.(DCSG00080451 (Port Of Defect DCSG00102024) -WG:LSA provides controller operation option of starting patrol read when there are only raid 1 VDs created using NMVe PD's(DCSG00257688 (Port Of Defect DCSG00312024) -RWC3 for Windows breaks when testing email on SMTP Port 587(DCSG00298491 (Port Of Defect DCSG00307805) EnhancementRequest: -LSA credits page update with latest open source components(DCSG00074643) -LSA Client: NVMe Drive Init failure Error Reporting(DCSG00085790) -LSA Server: NVMe Drive Repair - Handling Event(DCSG00086254) -Added the current Speed Column to phy and lane speed table(DCSG00075198) -MegaAPI: Add API changes for Support Parity Read Cache Bypass (PR: DCSG00245039)(DCSG00370441) -MR API: Change event class for SPDM events(DCSG00134416) -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI STAT(DCSG00222915) -LSA_Server: Fetch and Display Port name and Box number for NVMe drives with Init error/repair(DCSG00373455) -Update X-Content-Type-Options to Header(DCSG00342485) -LSA changes to implement the PR:DCSG00152043(DCSG00216430) -Restore Factory Default doesn't prompt user to reboot the system after being performed(DCSG00120443) -(DCSG00082479) -MR7 - LSA_Common: Support WJ Pinning for both WB and WT Parity RAID VDs(DCSG00214470) -API change to add connector index as part of NVMe Init Error drive information(DCSG00352896) -SPDM support changes(DCSG00092939) -LSA 64bit support - disconnect 32 bit(DCSG00243701) -Update Nginx Settings and allow download server report for admin users(DCSG00347344) -MegaAPI: Add Event for possibility of incomplete writes on parity VDs with no battery backup (ER: DCSG00229751)(DCSG00405671) -Support for Ubuntu v18.04 OS(DCSG00081316) -MFI SMP Port Num API changes(DCSG00257777) -Upgrade of OpenSLP source Code(DCSG00167228) -Warning events including Predictive failure (code 96) to add the new property to the drive(DCSG00074191) -Cleaning up LSA Readme file(DCSG00086337) -Major version upgrade of OpenSSL(DCSG00075194) -LSA Common: Enhance OEM build generation on Standalone server(DCSG00138907) -MR7.15: LSA - Linux 32 bit binary removal in Standalone Environment(DCSG00228734) -LSA Server: Enhance development environment to maintain OEM specific projects(DCSG00129446) -Add new security events(DCSG00167313) -Multi path Display Enhancement in the Client(DCSG00075193) -LSA_7.16: Enhance Make Release process(DCSG00339979) -Enhance LightWeightMonitor build process(DCSG00093307) -MR API: create a new DCMD for BMC to initiate an expander reset(DCSG00362825) -SMART Polling Improvement- API Changes(DCSG00214352) -LSA MR7.16: Ruby SED Support(DCSG00265657) -storcli does not show the SAS Address of the enclosure(DCSG00255107) -MR API: reclassify MR_EVT_CTRL_FW_VALID_SNAPDUMP_AVAILABLE as informational(DCSG00292323) -Eliminate reporting of capacitance over 100%(DCSG00149664) -Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10(DCSG00074194) -Updated 3rd party libs(DCSG00286594) -New MFI Stat for the updated recon behavior(DCSG00229416) -MegaAPI: rename WJ events and change event messages (PR: DCSG00166915)(DCSG00332867) -MegaAPI: Add API changes for Support WJ Pinning for both WB and WT Parity RAID VDs (PR: DCSG00166915)(DCSG00312334) -NVME Failed drive error reporting(DCSG00085936) -System Health Status update in case of multiple controllers present in system.(DCSG00075224) -(DCSG00082474) -MR7 API: Add package incompatibility reporting(DCSG00231443) -MegaAPI: Add API Controller Properties and MFCD for ParityReadCacheBypass (PR: DCSG00237022)(DCSG00282676) -Manual Discovery Enhancements(DCSG00149397) -SPDM Support for Aero in LSA GUI(DCSG00076958) -Script build process for arm and esxi LSA(DCSG00075216) -LSA 64bit support - disconnect 32 bit(DCSG00243703) -Additional NameSpace behavior changes(DCSG00383671) -Add the Force Refresh for Cache module in LSA(DCSG00219527) -SMART Polling Improvement - API Changes(DCSG00246317) -To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h(DCSG00256271) -Additional FDE type for Ruby SED support(DCSG00055878) -LSA Client: NVMe Drive Repair(DCSG00085927) -Build Enhancement - Automate standalone build generation(DCSG00075220) -Populating port name of a UBM U.2/3 backplane with NVMe drives(DCSG00132390) -MR_SAS_PHY_LINK_SPEED should indicate that the link is not active(DCSG00073569) -MR7.16 - LSA Server: SAS Address and LogicalID fields missing in enclosure properties(DCSG00255108) -Optimize Server Report Generation(DCSG00351905) -LSAServer: Add the Force Refresh for Cache module in LSA(DCSG00218902) -Convert LSA installation scripts from csh to sh(DCSG00075219) -Remove bays on port for Shenandoah For MRSA(DCSG00101417) -LSA Common: NVMe Drive Repair - Event and MFI state notification(DCSG00086253) -Multi path Enhancement in the server(DCSG00071167) -Upgrade the Install Shield Version to 2020(DCSG00219077) -Optimize LSA Server code Compilation Time(DCSG00075222) -LSA Server: Autoconfig API Improvement(DCSG00212945) -Upgrade GWT from 2.8.1 to 2.8.2(DCSG00110240) -LSA Server: NVMe Drive Repair(DCSG00085947) -Enhance Standalone RWC3 build process(DCSG00124860) -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode(DCSG00151058) -Request to add checks (DevId, SubDevice Id) check prior to flashing(DCSG00396121) -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API(DCSG00226286) -(DCSG00152596) -Implemented: setting appropriate permission for files and directories(DCSG00351962) -LSA needs to add the new adapter name to the support matrix hence marking it to Small to update the support matrix in readme(DCSG00075062) -Upgrade of OpenSLL and its dependent components(DCSG00124493) -LSA Client - Optimize Client Compilation Time(DCSG00075225) -MR7 : Support WJ Pinning for both WB and WT Parity RAID VDs(DCSG00214471) -API change to replace enum declaration with U32.(DCSG00393987) -API changes for reporting missing cables(DCSG00313199) -Changes to support 16port connection to Expander with AeroIOC(DCSG00254845) -MR 7.16: Make environment to generate MRMON 64 bit libraries(DCSG00308331) -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security SPDM(DCSG00106380) -Updated 3rd party libs(DCSG00286594 (Port Of EnhancementRequest DCSG00384441) -LSA_Server: Display Write Cache Settings for PD(DCSG00366367 (Port Of EnhancementRequest DCSG00373491) -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00354847) -Updated 3rd party libs(DCSG00286594 (Port Of EnhancementRequest DCSG00306730) -LSA Server: RRB141 - Ensure that the SSD cache policy is changeable and the status information is correct(DCSG00171246 (Port Of EnhancementRequest DCSG00228742) -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00384509) -(DCSG00167228 (Port Of EnhancementRequest DCSG00167257) -LSAServer: Add the Force Refresh for Cache module in LSA(DCSG00218902 (Port Of EnhancementRequest DCSG00225933) -Crypto Erase option for Cryptographic Capable Drive(DCSG00373462 (Port Of EnhancementRequest DCSG00384657) -LSA: Linux 32 bit binary removal(DCSG00221416 (Port Of EnhancementRequest DCSG00363675) -Linux: Installer script improvement(DCSG00130050 (Port Of EnhancementRequest DCSG00230033) -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00384472) -LSA_Common: Fetch and Display Port name and Box number for NVMe drives with Init error/repair(DCSG00373455 (Port Of EnhancementRequest DCSG00373474) -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00384513) -(DCSG00075222 (Port Of EnhancementRequest DCSG00081005) -(DCSG00098812 (Port Of EnhancementRequest DCSG00105863) -LSA: Linux 32 bit binary removal(DCSG00221416 (Port Of EnhancementRequest DCSG00408121) -SPDM support changes(DCSG00092939 (Port Of EnhancementRequest DCSG00113254) -BST Automation for LSA(DCSG00098812 (Port Of EnhancementRequest DCSG00218817) -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00354907) -CSET Port of EnhancementRequest DCSG00075194: Major version upgrade of OpenSSL(DCSG00075194 (Port Of EnhancementRequest DCSG00083924) -MR7.15: LSA - Linux 32 bit binary removal in Standalone Environment(DCSG00228734 (Port Of EnhancementRequest DCSG00293989) -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00348015) -CSET Port of EnhancementRequest DCSG00075194: Major version upgrade of OpenSSL(DCSG00075194 (Port Of EnhancementRequest DCSG00083925) -Added support for RHEL 8.3(DCSG00373404 (Port Of EnhancementRequest DCSG00428563) -(DCSG00096553 (Port Of EnhancementRequest DCSG00110100) -(DCSG00085947 (Port Of EnhancementRequest DCSG00086469) -(DCSG00286594 (Port Of EnhancementRequest DCSG00290207) -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00384205) -Update Nginx Settings and allow download server report for admin users(DCSG00347344 (Port Of EnhancementRequest DCSG00384206) -Implemented: setting appropriate permission for files and directories(DCSG00351962 (Port Of EnhancementRequest DCSG00385127) -Ensure that the SSD cache policy is changeable and the status information is correct(DCSG00214163 (Port Of EnhancementRequest DCSG00230031) -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00384499) -(DCSG00286594 (Port Of EnhancementRequest DCSG00286739) -LSA_client: Display Write Cache Settings for PD(DCSG00372331 (Port Of EnhancementRequest DCSG00383405) -Added support for RHEL 8.3(DCSG00373404 (Port Of EnhancementRequest DCSG00428561) -Optimize Server Report Generation(DCSG00351905 (Port Of EnhancementRequest DCSG00366266) -Crypto Erase option for Cryptographic Capable Drive(DCSG00369727 (Port Of EnhancementRequest DCSG00384592) -WebGUI: Automate the test cases specific to MR7.14 Product Requirements(DCSG00082499 (Port Of EnhancementRequest DCSG00086646) -Update X-Content-Type-Options to Header(DCSG00342485 (Port Of EnhancementRequest DCSG00384514) 007.013.016.000 - Moderate Impact --------------- MR 7.13 Defects: -Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down.(DCSG00112141 (Port Of Defect DCSG00080854)) -Legacy : WG: LSA auto logs in on clicking "verify" button for "Managed" VMware manually added server in managed server page.(DCSG00112744 (Port Of Defect DCSG00112178)) -MR controller with No Alram is not auto refreshing on changing the controller properties.(DCSG00124768 (Port Of Defect DCSG00124484)) -LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings.(DCSG00136282 (Port Of Defect DCSG00134600)) -LSA Server: WG MR 7.14 PA2: Advance configuration page is in hung state in presence of jbod drive and prepare for removal state.(DCSG00219183 (Port Of Defect DCSG00114253)) -LSA WG : LSA "Download Diagonstic" field is not downloading the ttylog in Readonly access..(DCSG00219184 (Port Of Defect DCSG00083816)) -Secured foreign locked VDs details are not displayed under foreign configuration to import/clear foreign config.(DCSG00221295 (Port Of Defect DCSG00103239)) -Credits page needs an update.(DCSG00233292 (Port Of Defect DCSG00232932)) -WG 7.14 PA2: Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 7.8.(DCSG00233700 (Port Of Defect DCSG00092841)) -On ARM server, on every reboot LSA services are stopped: Ubuntu 18.04.(DCSG00233701 (Port Of Defect DCSG00105871)) -Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2.(DCSG00233702 (Port Of Defect DCSG00115253)) -MR Controller Downloaded Diagnostic Data has Deviceid set to 0 in line number 12.(DCSG00233703 (Port Of Defect DCSG00125594)) -LSA 7.14 : Clicking on "Configure" option from server landing page is redirecting to controller info page instead of Advanced config page..(DCSG00233704 (Port Of Defect DCSG00125950)) -fixed: changed unit to Byte in case of zero size drives.(DCSG00233705 (Port Of Defect DCSG00072680)) -Non-interactive/silent installation does not have options to install LSA based on EVENT NOTIFICATION CHOCIES..(DCSG00233706 (Port Of Defect DCSG00078199)) -WG MR 7.14 PA1: LSA allows to select 512B drives as DHSP for 4K DG.(DCSG00233708 (Port Of Defect DCSG00078853)) -WG 7.14:During VD creation filtering 4k drives displays blank PD table when mixing is not allowed.(DCSG00233709 (Port Of Defect DCSG00078974)) -LSA Client: Behavior mode parameters is not shown.(DCSG00233710 (Port Of Defect DCSG00079966)) -VDs of different capacities(MB/GB) is not sorting properly..(DCSG00233711 (Port Of Defect DCSG00080102)) -Legacy: LSA WG: LSA is allowing to change the personality mode of the controller in Non-admin access..(DCSG00233712 (Port Of Defect DCSG00083219)) -Silent installation with default Web server port and default LSA port is failing..(DCSG00233713 (Port Of Defect DCSG00092962)) -WG 7.14 PA2:managed server icon for self server is shown "add" in manage server page if we add ubuntu/ any server to manage server list..(DCSG00233714 (Port Of Defect DCSG00112829)) -LSA WG : Uninstall instructions mentioned in LSA ESXi readme is wrong..(DCSG00233716 (Port Of Defect DCSG00126899)) -Manage server page throws error message "400:" for invalid credentials..(DCSG00233717 (Port Of Defect DCSG00136334) -WG: LSA Does not have filter button in drives tab for IT controller Controller console page.(DCSG00233718 (Port Of Defect DCSG00138885)) -Fixed: Spanned drive min vd check calculation error.(DCSG00233720 (Port Of Defect DCSG00138063)) 007.013.014.000 - Moderate Impact ------------------------------------- MR 7.13 Defects: -WG 7.13:Inconsistency in display of "Patrol Read" in the Properties page.(DCSG00071276) -Changing the ngroups list values.(DCSG00102619) -Shenandoah_MRSA : change personality option should not be enabled for both with linux and windows releases.(DCSG00072698) -Whitley ICX : LSA - Add physical drives option is not coming for user when trying to recon from R6 to R0.(DCSG00104470) -Fixed: Added disable nginx logging flags.(DCSG00065714) -Memory Leak issues in LSA Build.(DCSG00068484) -WG: Alignment issues in Remote discovery page, server summary page and Settings page.(DCSG00065480) -IT controller is not displayed int the view all controllers tab when it is in needs attention.(DCSG00061513) -Manual discovery page gets hung while adding the server to Auto discovery list..(DCSG00080451) -WG: Clicking on Manually added server in manage server page leads to blank page (calls fails with 502 error code).(DCSG00063209) -LSA: disableOffloadNum field should be match with latest schema.(DCSG00041224) -Channel controllers are discovered from MRSA Software.(DCSG00054278) -Fixed: user notification client list is not updated.(DCSG00053648) -WG 7.13: Hot spare Filter box alignment issue.(DCSG00067986) -LSA Common: LSA Crypto OEM specific changes.(DCSG00047290) -Windows installer (7.013.004.000) is unsigned.(DCSG00065620) -Cannot update CFF 440 FW with LSA.(DCSG00062602) -Firmware update page shows "None" for selected firmware.(DCSG00065566) -Orion MR PA10 - Foreign config is not showing properly in LSA when user pull/push the PD.(DCSG00053829) -due to unhanded battery removal event, battery health status was not reflecting as need attention.(DCSG00040271) -WG: Energy pack details does not load on clicking energy pack properties after clicking Refresh energy pack properties.(DCSG00058132) -MR7.13: Enhance debug Log level and entries in LSA Common code.(DCSG00041751) -Fixed:display of 2 enclose when only one is connected with multi path.(DCSG00069728) -LSA MR: Hand symbol is showing for all the fields in Server Profile and it is not clickable.(DCSG00062470) -WG: In presence of JBOD, after creating VD using all UG drives, the advanced configuration button gets disabled.(DCSG00065733) -update HBA 440-16i UEFI BSD failed via LSA.(DCSG00074275) -MRSA Firmware update page shows ,Selected Firmware Package version and it shows Firmware version.(DCSG00051098) -WG: Instance validation fails for Enclosure GET( MR 7.13, 7.013.004.000.(DCSG00066930) -MR-7.12: LSA VD creation failure message has spacing formatting issue..(DCSG00037910) -LSA Client : Non-VMware server is discovered with VMware check box enabled in Manual Discovery.(DCSG00051290) -Partial degraded VD icon is showing as optimal VD icon in LSA.(DCSG00054282) -WG: Duplicate entries of physical drive properties are displayed in case a property of physical drive is updated.(DCSG00069285) -WG 7.13: Patrol read option not seen for GHS in LSA.(DCSG00068977) -WG: Instance validation fails for Controllers GET (MR 7.13, 7.013.004.000), : Aero Controller.(DCSG00067932) -Remote discovery fails to load in RWC3 (7.013.009.000.(DCSG00083835) -Fixed: usage of wrong enum led to unknow characters in max lane width.(DCSG00049771) -WG: For the self server adding a read only user in manage-server page is logged in as a admin user.(DCSG00065605) -AMD 2P - LSA is not showing proper information when user trying to do RLM with same RAID level.(DCSG00040578) -MR 7.13 DBU: Flashing BIOS package failure with Completed status on Aero Controller when selected EFI-BSD.(DCSG00055757) -Windows Un-installer is not removing the SL Debug logs.(DCSG00054660) -WG MR7.13: LSA read me file needs to be updated with New OS matrix and inclusion of Aero cards.(DCSG00055714) -WG: Refresh energy pack properties displays error notification with status code : 1 on Vmware login.(DCSG00058321) -Notification for Enable /Disable security box is not pointing to Enable/Disable security option..(DCSG00067992) -LSA Server: LSA Crypto OEM specific changes.(DCSG00047618) -Handling Manual Discovery ADD case.(DCSG00077625) -LSA is not allowing user to change max number of PDs allowed under Set Patrol Read properties.(DCSG00068620) -Negotiated width and Max lane width property parameters for Nvme drives is shown as "Max user count reached" in LSA.(DCSG00046456) -Unmap property not update in VD/PD on enabling/disabling unmap at controller level.(DCSG00040172) -Server Profile _Linux: enclosure/Backplane information is blank / ServerIP is private in Linux OS.(DCSG00072694) -key board short cut does not work after using the print button during the installation.(DCSG00064684) -MR-7.13: LSA event ID 614 shown as Blank..(DCSG00037968) -WG: Changes required in naming convention of LSA to RWC3 in linux installation, RWC3 end user text has junk unicode characters in place of quotes and typo's.(DCSG00058406) -LSA_ 32 bit installer fails to launch in RHEL 8.1.(DCSG00087274) -Shenandoah:MRSA- Online Help gives 404 Not Found.(DCSG00051063) -Manage SAS Storage Link Speed/Premium feature/Manage Pcie Storage Interface operations have missing table borders & issues pertaining to column separators of the table.(DCSG00068937) -LSA MR : Each box in the List view of server page shows handsymbol but it is not clickable.(DCSG00062228) -RWC3 Common: Updating x64 nginx file.(DCSG00068595) -WG: clickable Checkboxes and "Confirm" notification texts does not have clickable mouse hover hand icons.(DCSG00069230) -LSA Client : NVMe Drive property changes w.r.t schema v32.(DCSG00079364) -MRSA shows " 0 Needs attention " when controller health status is "Needs attention ".(DCSG00056573) -WG: No LSA support logs generated with 7.013.003.00 linux Gateway.(DCSG00059955) -Orion MR PA10 - Same RAID level migration throws an error in LSA if user adding and removing any drives.(DCSG00053821) -Enhance the message of locked foreign can not be imported to cover boot time password skip.(DCSG00071157) -LSA Client : disableOffloadNum field should be match with latest schema.(DCSG00053497) -LSA Server: Resolving merge issues.(DCSG00032674) -Fixed:handled discovering multiple controllers.(DCSG00024769) -AMD 2P Wave2: LSA- Not able to create RAID00 with more than 32 PDS.(DCSG00042409) -Lone LF in body of email message.(DCSG00078494) -LSA is getting timed out while creating R6-64 VDs using 32 PDs.(DCSG00049772) -AMD2P-Wave2- LSA: Same RAID level migration throws an error in LSA if user adding and removing any drives.(DCSG00068647) -Ventura MR FW: Push Pull of drives showing wrong Enclosure ID..(DCSG00060541) -WG: Few of the keyboard shortcut keys are not working in case of RWc3 installation.(DCSG00058142) -MR-7.13: LSA Foreign import button not grey out after import is clicked with 240 VDs..(DCSG00068136) -StorCLI and LSA are not in sync while displaying the NVMe drive model Number after inserting the drive back..(DCSG00054602) -WG: Instance validation fails for PHY's GET and phy/0 GET (MR 7.13, 7.013.004.000.(DCSG00066942) -Use NVRAM to save PTB information -- API changes.(DCSG00082981) -Issue found due to code merge during code delivery process.(DCSG00075210) -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424) -MRSA: Supported controller information in the Readme File needs to be updated.(DCSG00056669) -Enter Key issue in Manual Discovery page is searching the servers without entering the IP..(DCSG00071404) -WG: For the self server which will be added to managed server by default should not show verify button.(DCSG00068954) -ICX_Whitley_Orion: LSA- Link speed details are not showing properly for Tape drive in WebGUI.(DCSG00075777) -"delete config" command clears the config, when OS/FS in the drive without "force" option.(DCSG00077464) -RWC3 windows build (07.013.009.000)loads with http instead of https.(DCSG00083839) -LSA MR Ventura: Alarm info is showing wrong when controller info tab is expanded..(DCSG00062219) -LSA report Power supply status only after LSA service restart.(DCSG00086465) -WG: LSA install shield says ready to install "OpenSLP 3.0.0.0 Arm64" instead of "openSLP 2.0.0.0 x86".(DCSG00063219) -Channel controllers are discovered from MRSA Software.(DCSG00053971) -Fixed: updated max drives for configuration service API.(DCSG00045337) -WG: Issues pertaining to schedule consistency check.(DCSG00069219) -Fixed: used data drives instead of total drive whie calculating min vd size.(DCSG00033996) -Orion_LSA: Maddux_Chinook: Slot numbers shown as 255 after expander resets.(DCSG00045472) -Fixed: Added minimum log support for thin OS.(DCSG00058212) -Display of unmap property at VD level.(DCSG00037620) -After installation of HPE_Generic linux 64 bit RPM, LSA service is not getting started..(DCSG00056838) -WG: Typo's in Readme and LSA.conf.(DCSG00058412) -Typo's in LSA.conf.(DCSG00061049) -WG: Copyright info needs to be updated from 2019 to 2020.(DCSG00068495) -LSA Readme file has to be updated for Aero controller support and proper open SLP web link..(DCSG00054273) -Inconsistency in the Server profile Headline representation.(DCSG00068909) -WG: Manual discovery page allows the user to add already added manually added VMware server.(DCSG00059470) -LSA Server: RAID volume creation failing with strip size conversion.(DCSG00048632) -LSA Client : Slot numbers shown as 255 after expander resets.(DCSG00055108) -LSAServer: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00008078 (Port Of Defect DCSG00025255)) -Ubuntu Linux install issues.(DCSG00032286 (Port Of Defect DCSG00033488)) -LSA does not display Virtual drive info for foreign configuration.(DCSG00035555 (Port Of Defect DCSG00071356)) -Legacy WG: Verify Credentials of the manually discovered server in Manage server page does not check if server is down.(DCSG00080854 (Port Of Defect DCSG00112141) -Fixed:LSA increased memory consumption with each event.(DCSG00031835 (Port Of Defect DCSG00070333)) -Fan, Temperature Sensor , Voltage Sensor property issues related to Atlas board.(DCSG00035711 (Port Of Defect DCSG00071360) -Credits page needs an update.(DCSG00232932 (Port Of Defect DCSG00235896)) -LSA _MR :- Error/warning message not displayed when unsupported characters entered for changing drive rate settings.(DCSG00134600 (Port Of Defect DCSG00136282)) -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0.(DCSG00063716 (Port Of Defect DCSG00065590)) -When create or delete VD in LSA, VD information didn't refresh under LSA web in VMWare 6.7.(DCSG00068509 (Port Of Defect DCSG00069274)) -LSA getting hung while loading in windows 2019 OS on Stonyford server.(DCSG00058328 (Port Of Defect DCSG00058797) -Health status changes of the remote server does not get updated in the gateway remote discovery page.(DCSG00086628 (Port Of Defect DCSG00087296) -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424 (Port Of Defect DCSG00071283)) -RWC3 Home Page Help Button Hyper Link is Broken.(DCSG00050748 (Port Of Defect DCSG00061255)) -LSA Client : Handle Manual Discovery failure cases.(DCSG00098052 (Port Of Defect DCSG00098056) -Starting LSI Storage Authority is seen in failed state during LSA installation on Rhel 8.2.(DCSG00115253 (Port Of Defect DCSG00239461) -LSA read me: Update the read me with all the required OS list.(DCSG00222589 (Port Of Defect DCSG00239476)) -When selected 6272 KB firmware for update failure seen with message as file is more than 16MB size.(DCSG00080838 (Port Of Defect DCSG00102801)) -Fixed: updated build script to add dirty bit to modifiable files. configuration file for client wasnot set with modifiable bit (+T)..(DCSG00058424 (Port Of Defect DCSG00070664) -Manual Discovery failure shouldn't return HTTP status:200.(DCSG00098024 (Port Of Defect DCSG00098034) -MR controller with No Alram is not auto refreshing on changing the controller properties.(DCSG00124484 (Port Of Defect DCSG00124768)) EnhancementRequests: -Support for the New Energy Pack states.(DCSG00042776) -Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG.(DCSG00105430) -API change to support ISE completion status.(DCSG00065881) -MR API: Change event class for SPDM events.(DCSG00134416) -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI STAT.(DCSG00222915) -LSA Standalone - port enhanced authentication/authorization to Linux.(DCSG00025327) -DCSG00234646 -HPE Shenandoah: Type 2 Back plane Support.(DCSG00054712) -Linux: Installer script improvement.(DCSG00130050) -Remove Span setting for RAID 1 & 10.(DCSG00039596) -Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713) -MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534) -Implement support for Cross certificate and command - Windows signing using CNG Provider with HSM Protected Key.(DCSG00030211) -Allows cleaner exit with flushing of logs.(DCSG00039065) -DCSG00129388 -DCSG00067060 -Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066) -Enhance debug Log level and entries in LSA Server code.(DCSG00038025) -Signing Linux executables via GPG method in HSM.(DCSG00077215) -Implemented: Logs levels appropriated.(DCSG00038028) -MR7.13: Enhance debug Log level and entries in LSA Server code.(DCSG00038019) -Request to change all BBU messages to CacheVault or Energy PAck as appropriate, since no longer supporting BBUs on latest Ventura products.(DCSG00031355) -Implemented secureSignCNG.exe CLI signing tool for Windows Signing..(DCSG00023491) -Blocking Management and display of the profile and Personality in MRSA as user can not change profile or personality from MRSA.(DCSG00041350) -SSD Wear Gauage.(DCSG00042810) -MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355) -Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780) -Update RAID Web Console 3 solution to remove or re-direct Feedback.(DCSG00026525) -Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00214163) -Port secureSignBin.exe for MARGAY signing to GCP server environment.(DCSG00040377) -MR7.13: Enhance debug Log level and entries in LSA Server code.(DCSG00038027) -Request to change all BBU messages to CacheVault or Energy PAck as appropriate, since no longer supporting BBUs on latest Ventura products.(DCSG00031716) -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058) -MR7.13: Enhance Server report log collection.(DCSG00039063) -HPE Shenandoah: Type 2 Back plane Support MRSA Client.(DCSG00054716) -Add new security events.(DCSG00167313) -Upgrade Install shield 2019.(DCSG00039535) -Support for the New Energy Pack states.(DCSG00042778) -LDET - Qx-2020 - RRB149 - Add immediate-binding flag to gcc-compiled deliverables.(DCSG00025854) -MR API: update field in event structure..(DCSG00093331) -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286) -MR7.13 - LSA Client: Update Snapdump save count field in show snapdump command.(DCSG00039516) -Updated secureSign.exe CLI tool and server-side controller scripts to use GCP server resources.(DCSG00003371) -SMART Polling Improvement- API Changes.(DCSG00214352) -LSA Server: RRB141 - Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00171246) -FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event from Info to Warning.(DCSG00086780) -New MFI Stat for the updated recon behavior.(DCSG00229416) -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security SPDM.(DCSG00106380) -Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847) -MR7.13 - LSA Server: Update Snapdump save count field in show snapdump command.(DCSG00039505) -MR7 API: Add package incompatibility reporting.(DCSG00231443) -Aero multi-party signing partial signing of images.(DCSG00048670) -DCSG00025854 (Port Of EnhancementRequest DCSG00039673) -Multi path Enhancement in the server.(DCSG00071167 (Port Of EnhancementRequest DCSG00075640) -Linux LSA HSM based signing support.(DCSG00038899 (Port Of EnhancementRequest DCSG00042392)) -Ensure that the SSD cache policy is changeable and the status information is correct.(DCSG00214163 (Port Of EnhancementRequest DCSG00240010)) -LSA credits page update with latest open source components.(DCSG00074643 (Port Of EnhancementRequest DCSG00074715) -Windows LSA HSM based signing support.(DCSG00038808 (Port Of EnhancementRequest DCSG00042391) NOTE TO SERVICE - Reference RETAIN #N/A 007.012.015.000 - Moderate Impact ------------------------------------- Defects Fixed (100) -Fixed:LSA increased memory consumption with each event(DCSG00031835) -Scheduler Panel not aligned to center if Operations are performed on 32 VDs.(DCSG00016270) -Enable SSD guard fails with the error code : 3: Description: The requested command has invalid arguments.(DCSG00008031) -WG: Readme changes as part of MR 7.12.(DCSG00031356) -fixed: allow Cachecade VD creation.(DCSG00022978) -Aero DBU alpha (LSA):LSA crashes when make jbod/UG performed on multiple drives with Schedular wrapper enabled.(DCSG00024414) -7.12_EXT New OS support Matrix.(7.12_EXT New OS support Matrix).(DCSG00011435) -WG: Filtering with VMware and searching for auto discovered windows/linux server in manual disc page results in both success and failure messages.(DCSG00010481) -fixed: nginx logs consuming large space on disk.(DCSG00032280) -WG:alignment issue in notifications.(DCSG00007250) -LSAServer: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00008078) -Hide the Energy pack information when it is not present.(DCSG00031701) -Uninstall successful message not seen with RHEL OS & install exists with unary operator message if user provides input other than Y/N.(DCSG00012335) -SLES 15 Linux: Installer messages while creating symbolic link.(DCSG00023294) -LSAServer: Cleanup unused variables from LSA Crypto algorithm.(LSAServer: Cleanup unused variables from LSA Crypto algorithm) -Fan, Temperature Sensor , Voltage Sensor property issues related to Atlas board..(DCSG00035711) -"Your connection is not private" text overlap seen at manage server page.(DCSG00017191) -StoreLib API: Update SL_GET_ENCL_LIST with cmdParam_1b[0] for extended/legacy enclosure structures.(DCSG00053982) -WG: Aero DBU PA6(LSA): Performing VD operations does not update/clear the element count.(DCSG00012010) -Fixed: changed packaging script appropriatley.(DCSG00011424) -LSA Cache update for PD insert for it ctrls.(DCSG00020315) -Login Button gets disabled when user name is filled and Authentication Fails.(DCSG00014659) -LSA install exits if the user clicks enter key on any point during installation.(DCSG00026178) -MR 7.12: LSA Client- Coverity Defect Fixes.(DCSG00028104) -Modify the Alert setting put request to send only delivery mechanism when Email is not modified.(DCSG00007449) -MR-7.12: FW EPD bit is enabled in RAID personality Mode..(DCSG00036066) -WG: Remote discovery page does not load with RWC3 gateway installation: MR 7.12.(DCSG00057422) -Fixed: library to communicate with vmware server for arm.(DCSG00010202) -LSAClient: Labeling mismatch between Enclosure Index and Enclosure ID.(DCSG00012720) -SLES 15 Linux: Un-Installation is not removing the complete folder structure.(DCSG00023296) -fixed: show only eleigible Raid level for migration.(DCSG00025527) -WG_7.12: On SLES 15 OS, After login, on doing some basic operations LSA, it redirects to 50x.html.(DCSG00022866) -Refresh the Client page on Enclose link Restore and link lost.(DCSG00014979) -Resolved built time dependency.(DCSG00008091) -LSA Common:Enhance user notification about the unsecured connection.(DCSG00008073) -WG 7.12 Alpha:Jbod conversion is not happening with OS drive.(DCSG00031718) -WG: no notification regarding "EMAIL/SMTP server related setting get modified" when user hovers between mail server and Email tab while adding email.(DCSG00020145) -LSA - AMD 2P Wave 1 - LSA is getting crashed while upgrading from 007.012.004.000 to 007.012.005.000 version.(DCSG00022361) -WG:7.12 Alpha : Enable/disable Scsi Unmap option not shown for the VD created using unmap capable drive..(DCSG00026497) -LSA Linux: Maintain the resource files across the build upgrade.(DCSG00007897) -LSA Server : JBOD removal/insert events in LSA are not compliance with FW Events..(DCSG00032366) -(LSA):Facing " ./LSA: ./libssl.so.1.0.0: no version information available" error while LSA installation.(DCSG00022170) -Fixed: Simple configuration feature is disabled if unconfigured drives are not available.(DCSG00025334) -LSA Common: Update the script files specific to LSA Crypto.(DCSG00031407) -IR Client Refresh: On Start/Stop CC.(DCSG00017218) -Libutils and Libutils2 scripts changes.(DCSG00012770) -LSA does not display Virtual drive info for foreign configuration.(DCSG00035555) -WG: Windows Direct agent not getting discovered in remote discovery page as well as manual discovery page.(DCSG00009390) -LSA AMD2P Wave 1: User is getting wrong info about max number of PD support for R1/R5 while doing RLM.(LSA AMD2P Wave 1: User is getting wrong info about max number of PD support for R1/R5 while doing RLM) -Ubuntu Linux install issues.(DCSG00032286) -Fixed: Slpd supported for rhel/sles/ubuntu is packaged.(Fixed: Slpd supported for rhel/sles/ubuntu is packaged) -StoreLib header: Update comments in Topology structures for attached devices to Atlas.(DCSG00061230) -WG 7.12 Alpha: LSA continues to be in debug mode when "./LSA -" executed for configuring LWM alert settings.(DCSG00028583) -When create or delete VD in LSA, VD information didn't refresh under LSA web in VMWare 6.7.(DCSG00068509) -WG: non Generic Icon shown for IT in CC page, typo in batch failure notification, no notification for premium feature key above 40 character.(DCSG00027350) -WG: LSA -console enters an infinite loop on entering a character/string as input.(DCSG00008008) -LSA upgrade fails from 7.10 patch RO to 7.12 RO with ./deleteOldVersion.sh: line 79: ((: 009: value too great for base (error token is "009") in SLES 12 SP4.(DCSG00014016) -Client: Schema changes for lanes.(DCSG00010703) -LSA does not allow the user to configure alert settings.(DCSG00031332) -WG: MR 7.12 : Arm SLIR3 version is shown empty in view server profile.(DCSG00008006) -LSA - AMD 2P Wave1 - Same RAID level migration throws an error in LSA if user is not adding/removing any drives.(DCSG00028267) -LSA GUI display empty page when launching the app.(DCSG00014599) -LSA Server: Handle new MFI status in LSA.(DCSG00031865) -fixed: updated LSA version.(DCSG00008023) -LSA Server: Add MRMonMsg project to the LSA solution.(DCSG00007928) -Fixed: lane width is displayed as unknown.(DCSG00035811) -Schema changes for lanes.(DCSG00010702) -On ARM server during LSA upgrade, ./deleteOldVersion.sh: line 53: LSIStorageAuthority: command not found error is observed.(DCSG00025403) -WG: lsa.exe -console fails to execute with LWM installed on windows machine.(DCSG00007461) -ARM Ubuntu: Linux Uninstallation leaving slpd process alive.(ARM Ubuntu: Linux Uninstallation leaving slpd process alive) -WG: Manual discovery of the ubantu server from windows gateway lists it as VMware server, issue related to search and adding already discovered server.(DCSG00010474) -Fixed: Added aarch64 detection code for linux.(DCSG00008022) -LSA Advanced Configuration does not work with controller is with RAID mode , Personality behavior=RAID-0.(DCSG00063716) -Even after LSA is uninstalled the LSA and Nginx port numbers are still busy, reinstallation requires using alternate free ports: Ubuntu.(DCSG00011517) -Address property Display mismatch for PD and Enclosure properties for MR and IT.(DCSG00017217) -LSA Server: External defect review:id=45919.(DCSG00007404) -For unconfigured bad drives, typo in Negotiated link speed & Drive speed in physical Drive properties page.(DCSG00007251) -Fixed: Resolved primary nic interface data population.(DCSG00010261) -LSA under Drives for IT controllers is showing selected elements 0 always.(DCSG00015834) -WG_7.12_LSA: Invalid VD size range notification is shown on entering VD capacity out of range.(DCSG00007446) -WG: Aero DBU Alpha(LSA): Select all snapdump --> deselect one of snapdump and then click on headline deselects all selected snapdumps.(DCSG00027305) -Fixed: missing span was not handled appropriately in DG health.(DCSG00027676) -WG: Mutliselect PD notification for IT controllers notifies user to select multiple Virtual Drive rows, clicking on FW version does not lead to FW update page.(DCSG00027320) -LSA crashes when clear drive operation performed.(DCSG00022528) -WG: during uninstallation of LSA from the control panel the publisher information is not shown in windows.(DCSG00042280) -Fixed: slpd didnt start durint startup.(DCSG00011426) -LSA Common: Handle events 610-613.(DCSG00008066) -Fixed: updated openssl library.(DCSG00010277) -WG:7.12:abort core dump seen for rekey operation on LSA..(DCSG00009381) -RWC3 Home Page Help Button Hyper Link is Broken.(DCSG00050748 Port Of Defect DCSG00057415) -WG: Copyright info needs to be updated from 2019 to 2020.(DCSG00068495 (Port Of Defect DCSG00068560)) -DCSG00037620 (Port Of Defect DCSG00037685) -LSA Server: Resolving merge issues.(DCSG00032674 (Port Of Defect DCSG00032824)) -LSA Readme file has to be updated for Aero controller support and proper open SLP web link..(DCSG00054273 (Port Of Defect DCSG00062969)) -Add the language support matrix in to LSA readme.(DCSG00024412 (Port Of Defect DCSG00024705)) -LSA IT : Not able to sort the drives based on drive "Model"..(DCSG00032171 (Port Of Defect DCSG00048474)) -LSA getting hung while loading in windows 2019 OS on Stonyford server.(DCSG00058328 (Port Of Defect DCSG00058796)) -LSA MR: VD(Raid5) status is showing as degraded, instead of offline..(DCSG00032167 (Port Of Defect DCSG00032180)) -LSA show incorrect physical drive information, when drive push pull operation performed..(DCSG00026587 (Port Of Defect DCSG00026634)) EnhancementRequests: -LSA Server:Add security-related compiling flags to LSA 3rd Party Components.(DCSG00010237) -Ubuntu support for RWC3.(DCSG00016264) -Enhance user notification about the unsecure connection.(DCSG00008000) -Linux LSA HSM based signing support.(DCSG00038899) -LSA Windows: Maintain the resource files across the build upgrade.(DCSG00021254) -Windows LSA HSM based signing support.(DCSG00038808) -API change to support 1. OEM specific UBM Back planes, and 2. Smart Battery state.(DCSG00040165) -Update MR API mr_drv.h to modify field for RTTRace_header.(DCSG00042985) -LSA Common:Add security-related compiling flags to LSA 3rd Party Components.(DCSG00010240) -API change OOB Self Diagnostics Design Improvements.(DCSG00054194) -LSA to handle the new error code populated by the SL IT.(DCSG00024064 (Port Of EnhancementRequest DCSG00024476)) -DCSG00019108 (Port Of EnhancementRequest DCSG00019110). -DCSG00019108 (Port Of EnhancementRequest DCSG00019288). 007.010.016.000 - Moderate Impact --------------- Defect: LSA MR: VD(Raid5) status is showing as degraded, instead of offline.(DCSG00032167) LSA IT : Not able to sort the drives based on drive "Model".(DCSG00032171) LSA does not display Virtual drive info for foreign configuration.(DCSG00035734 port of DCSG00035555) WG_7.12: On SLES 15 OS, After login, on doing some basic operations LSA, it redirects to 50x.html.(DCSG00026970 port of DCSG00022866) LSA 7.10 + Ubuntu Linux install issues.(DCSG00032287 port of DCSG00032286) Aero DBU alpha (LSA):LSA crashes when make jbod/UG performed on multiple drives with Schedular wrapper enabled.(DCSG00026968 port of DCSG00024414) nginx logs result in large disk space consumption.(DCSG00032285 port of DCSG00032280) SLES 15 Linux: Un-Installation is not removing the complete folder structure.(DCSG00027735 port of DCSG00023296) EnhancementRequest Records Linked (4): New Event for firmware DMD handling StoreLib.h: Enhanced debug logging mechanism Storelib.h: Add new SL API SL_OOB_SET_TRANSPORT_TYPE to dynamically load SL in any oob mode API changes for Request to change all BBU messages to CacheVault. API changes needed for DPMstat support in MegaRAID SAS 3.5 controllers LSA 3rdParty :Add security-related compiling flags to LSA 3rd Party Components Automating Arm Builds 007.010.014.000 - Moderate Impact --------------- Defects (277) - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01874775) - Issues wrt the linux installer script(SCGCQ01879303) - WG: installing LSA on linux 64 bit machine throws an error " ‘/root/Desktop/LaunchLSA.desktop’: No such file or directory"(SCGCQ01897393) - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01898255) - LSA Event ID 519 shows blank.(SCGCQ01901169) - Incorrect icon displayed along with "settings saved" message.(SCGCQ01905838) - LSA:Loading More data initially in BGOPS Progress bar in LSA and later Device ID disappears(SCGCQ01937373) - PH10 PA LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01940193) - WG: No Action Successful notification shown on Drive erase(single Drive)(SCGCQ01941129) - LSA 7.9: Mismatch of sector size string between PD table and Group name(SCGCQ01942630) - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01949074) - LSA is not launching after a upgrade from v007.009.002.000 to 007.009.003.000(SCGCQ01949090) - Linux binary not working.(SCGCQ01949665) - WG: String Changes related to VD operations, Filter blank box turn blue, expand backplane icon can be removed when drives=0(SCGCQ01960486) - Fixed: WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963966) - SmartCarrier Enclosure type shown as "vSES" in LSA(SCGCQ01965395) - : MRSA shows Bay Count as 255 under Enclosure / Backplane properties(SCGCQ01965427) - LSA:Add Logical drive Page give option to select"Cached IO" for an LD and Error message not Branding compliant(SCGCQ01965445) - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01966275) - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01966687) - WG:GUI issues:50x Html file,View server profile with no enclosure,View More of System messages, Restore Settings notification(SCGCQ01968404) - WG: GUI issues Pertaining to alignment of notification on scroll of LSA page(SCGCQ01968457) - WG: LSA fails with the empty status description on trying to change the personality in presence of snapdump(SCGCQ01969570) - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ01970007) - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ01970452) - Port information missing under Enclosures List.(SCGCQ01972260) - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01972673) - Reference to BBU in Server profile page(SCGCQ01976904) - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ01976926) - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ01976929) - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01977769) - Fixed: Added check for missing drive case(SCGCQ01978914) - Fixed: LSA stops responding after creating Vd with 4k Drives(SCGCQ01978965) - VD/HotSpare reference in Clear Configuration Confirmation popup-Regression(SCGCQ01979076) - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01979137) - Error code is not displayed for DG add VD operation failure(SCGCQ01988209) - Modify array option available for Degraded R5 , Blank screen followed "0 drives" on removing drives(SCGCQ01988400) - Fixed: update Validation Check codes for the image file(SCGCQ01989969) - Aero A0: RWC3 does not show version of Selected Firmware Version for updating(SCGCQ01989970) - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL(SCGCQ01993099) - Fixed: OS name for localhost is inconsistent with the Osname populated when discovered via slp(SCGCQ01994459) - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ01998245) - Fix: WG: Intance validation for Controller Get fails : MR Ventura(SCGCQ01998299) - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998305) - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02006229) - WG: Switching between view server profile and settings page would not load the view server profile(SCGCQ02007150) - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure (SCGCQ02009718) - LSA 7.9: Action successful notification is not seen for encrypting the DG(SCGCQ02010670) - LSA: Mismatch in Unconfigured Good string(SCGCQ02016646) - LSA: Patrol Read string display issue(SCGCQ02016879) - WG : LSA 7.9 Status code for Drive security disable message is showing same for StatusLevel 0 and 1(SCGCQ02018083) - Difference in naming of Array during Array creation(SCGCQ02019200) - WG: GUI issues pertaining to star/stop patrol read & remote discovery page(SCGCQ02019555) - Back-plane information showing as blank in server profile page.(SCGCQ02019592) - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02021372) - LSA : Updating FW pkg version is not shown during FW upgrade/downgrade.(SCGCQ02023284) - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02023407) - LSA 7.10:Unsupported drives are displayed as UG under server profile page.(SCGCQ02030950) - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further(SCGCQ02032031) - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ02032824) - Error message displayed for entering wrong password to unlock foreign VD/PD should be updated.(SCGCQ02034263) - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02034466) - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02035158) - WG: mouse hover icon missing for the connected device property column in manage link speed pane(SCGCQ02035223) - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02035226) - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02035317) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02035322) - WG: Selected element count does not get updated after auto page refresh when VD expand operation is performed(SCGCQ02036089) -(SCGCQ02036091) - WG: wrong notification shown on trying to unlock a foreign FDE drive with wrong passphrase and then with correct passphrase(SCGCQ02036701) - Aero DBU PA1:LSA-Issue pertaining to add hotspare while creating Vd(SCGCQ02038235) - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02038386) - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW(SCGCQ02040516) - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02040739) - Shenandoah_MRSA: Warning message improvement when tried to delete LD formatted with File System(SCGCQ02042555) - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043781) - WG : LSA 7.10 Keyboard short cut keys are NOT there for Different pages of LSA Installation pages(SCGCQ02045646) - Fixed: OCR should trigger update of dual image components(SCGCQ02048856) - WG: Issues pertianing to set snapdump properties page--> enable disable snapdump and changing cache offload limit.(SCGCQ02048906) - WG: Incomplete foreign VD is seen when Clear foreign config is performed, incorrect status code on rescan after clear foreign(SCGCQ02049476) - WG:Securing JBOD option gets disabled if from list of JBODs selected even if one is unselected(SCGCQ02049479) - LSA displays one of the PD's is missing as part of foreign config even if all the PDs are connected(SCGCQ02049511) - WG: Few of VD and PD operations will not be usable in LSA without zooming out ((SCGCQ02049819(SCGCQ02049819) - WG: in presence of missing drive the select all and element count does not work properly in span drive tab(SCGCQ02050441) - WG 7.10:Advance controller info does not show whether energy pack is connected or not(SCGCQ02050502) - WG 7.10:Number of foreign config count is not updated if clear drive operation performed on a foreign pd.(SCGCQ02050579) - WG 7.10:Migration from r0 (31 pds(SCGCQ02050857) - Error and Warnings thrown while install/upgrade MRSA on SLES15(SCGCQ02053038) - WG: LSA notifications GUI issues & Other Hardware user info on expanding enclosure info, LSA conf file, Message_en file(SCGCQ02053156) - WG: UI Elements alignment for DG actions and Fixed action menu with lower resolution(SCGCQ02053167) - LSA Firmware package version shown as version in controller action page.(SCGCQ02053748) - LSA Simple configuration from main page shows blank when JBOD are present.(SCGCQ02053891) - Fixed: Last Vd size was not being checked for alignment(SCGCQ02058284) - Fixed: timestamp inside compressed file is not appropriate(SCGCQ02058485) - LSA capacity column sort not working in other Hardware Tab.(SCGCQ02058597) - Default Logical Drive name is showing as "VDName**" , while creating Logical drive through Simple Configuration(SCGCQ02062623) - WG: Element count not updated on selecting foreign drives and sorting Foreign drive list, it continues to show PD operations(SCGCQ02063630) - MRSA: LD Name discrepancy for 1 LD and 2 LDs without LD_Name during Array creation(SCGCQ02067043) - In presence of NVME drives, applying and Clearing filter and then sorting the drives results in incorrect PD list(SCGCQ02069473) -(SCGCQ02069524) -(SCGCQ02074686) - WG_7.10: Spacing alignments to be done in the VD setting page during the VD creation(SCGCQ02076790) - WG_7.10: While consistency check is in progress on VD, if we click pause progress bar is misaligned(SCGCQ02076792) - Fixed: check in place to create nvmeOnly disk group during migration(SCGCQ02076800) - WG: FDE foreign config after performing instant secure erase on one of the drive shows incomplete in LSA(SCGCQ02080536) - WG_7.10: Spell check and spacing issues in Latest LSA (007.010.003.000)(SCGCQ02081258) - "Drive Group list is empty" error message seen when multiple drives are assigned as DHSP to a VD, issue per(SCGCQ02081264) - Silent installation is NOT working on Ubuntu 16.04(SCGCQ02082129) - Download support Log not working.(SCGCQ02082514) - Aero (DBU PA3(SCGCQ02082524) - DG number displayed outside the box(SCGCQ02089434) - Aero DBU PA2(LSA(SCGCQ02091088) - WG: selected element count shown wrong on selecting PD list(including mising(SCGCQ02095469) - Fixed: missing pd info was leading to population of wrong candidate pds(SCGCQ02095494) - WG: LSA Lists drives of a type even if less for a raid level creation if user selects raid level from compare select(SCGCQ02096215) - Fixed: Changed build files to build client for ESXi(SCGCQ02096396) - WG: LSA snapdump files generated are only of 32 kb even if the actual snapdump file size is much higher than that(SCGCQ02100467) - WG: Filter options does not list NVMe drives in PD list of controller console page(SCGCQ02107270) - WG: extracting snapdump file using 7zip, user is notified regarding header error in etty file, spacingissue of text in OFU(SCGCQ02108538) - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02108817) - Fix API changes done for NVMe readiness(SCGCQ02142981) - Add NVMe width comments to mr.h(SCGCQ02146846) - Fixed: changed the max drive value of R1 for cachecade drives(SCGCQ02169419) - LSA - AWB option is coming for CC VD with Rambler card while creating CC VD(SCGCQ02169687) - LSA Cache update for PD insert for it ctrls(SCGCQ02191080) - WG: LSA does not display the correct VD creation time in VD get URI response(SCGCQ01889478) - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01902964) - LSA 7.9: Display error for "OS name" when expand/minimize is performed.(SCGCQ01904365) - Fixed: Configuration service changed to accomadate allomixinSSD bit(SCGCQ01925161) -(SCGCQ01927978) - LSA 7.9:Changing server parameter in Configfile.json file to 2 , scheduler does not kick inn and LSA crashes(SCGCQ01930410) - LSA 7.9 PA:failure messange with description success on enabling/disabling scsi unmap feature.(SCGCQ01936667) - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01940852) - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01942985) - Fixed: Foreign drives are not considered as configured & which leads to a mismatch in JBODconversion count during VD creation(SCGCQ01943388) - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01943617) - LSA 7.9: Mismatch in "Unconfigured drives and replace drive" count.(SCGCQ01944392) - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01952143) - LSA 7.9:Unable to start instanst secure erase operation on multiple Pds when scheduler is on.(SCGCQ01955160) - WG: Issues pertaining to Settings page(SCGCQ01956683) - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ01957078) - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ01960300) - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01962216) - LSA 7.9 alpha :The error code 69636 is seen without view more option when pause on CC operation is performed twice(SCGCQ01971576) - WG:LSA displays the snapdump count in hex value, GUI issues in snapdump pane(SCGCQ01973964) - MRSA event for Drive erase abort is coming blank in "View Event log" for event ID 421(SCGCQ01976894) - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ01978171) - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ01979083) - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ01979598) - LSA : Port details are missing in drive removal/insert events.(SCGCQ01979793) - Fixed: missing Event description for new events was pausing LSA(SCGCQ01980570) - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ01983080) - MRSA : Copyback progress details is not proper in BGI progress tab.(SCGCQ01996577) - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02003711) - WG: GUI issues : Drive Security text on Hover, system messages clickable text, bell button notification(SCGCQ02006538) - “404 Not Found” seen on upgrading Snap4 GA to OEM Builds and later removing and installing new build(SCGCQ02016688) - LSA 7.10:Covert button of the Jbod table is activated and flickers when more than eligible count pds are selected.(SCGCQ02024507) - WG: No VD or PD details shown for progress operation in VMware(SCGCQ02028695) - Shenandoah_Aero: LSA crash observed while trying to create more than maximum LD allowed(SCGCQ02031517) - WG : LSA Cache Offload Limit value change was not changing without manual refresh(SCGCQ02043843) - WG: LSA view event log list the Portmap as '0' instead of '08' for scsiType=0 (ie PDs)(SCGCQ02045715) - LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups.(SCGCQ02045735) - WG: LSA does not show the details of the current profile when there is only one profile supported(SCGCQ02045758) - WG: System LSA monitor event logs has junk characters(SCGCQ02049034) - WG: Path information for PD reset event is empty in event logs (event id : 268(SCGCQ02049577) - LSA: Domain login for administrator fails with "Error code:49 Invalid credentials".(SCGCQ02049807) - WG 7.10:if VD count is above limit and VD capacity is changed, LSA allows user to create VD which fails(SCGCQ02050533) - LSA Simple Configuration for R6 fails with error.(SCGCQ02053837) - LSA service crashing in ubuntu(SCGCQ02061370) - Linux Build is always picking old library(SCGCQ02061380) - Aero DBU PA2(LSA(SCGCQ02065672) - Incorrect number of slots is displayed for UBM U.2X2 Vses Backplane in LSA.(SCGCQ02069871) - Fixed: Calculation to get possible range for RLM(SCGCQ02070841) - Aero DBU PA2(LSA(SCGCQ02074776) - WG_7.10:In the Error code:118 description, Spacing alignments to be done.(SCGCQ02076794) - WG_7.10: SAS address is shown for PCIe (NVME(SCGCQ02076924) - Wide port info is not displayed for physical drive under connector name for Backplane attached drives.(SCGCQ02076933) - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02078435) - LSA: Read_only_access group users are given administrator privileges(SCGCQ02078614) - WG: User is notified to select the Drive group even if VD and PD tab of the DG is clicked(SCGCQ02080553) - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02081038) - During LSA upgrade some of the old build files are not removed in Ubuntu(SCGCQ02082116) - WG 7.10: wrong health status of a gateway server seen when discovered from same gateway server.(SCGCQ02084545) - WG:LSA Direct agent or LWM installation from main package creates desktop shorcut in linux(SCGCQ02084636) - WG 7.10:Scheduler wrapper does not kick in for enable security operation(SCGCQ02085660) - Fixed: FDE and Opal mixing shouldn't be allowed(SCGCQ02086784) - Migration from R1 Vd(4 drives)(SCGCQ02087362) - Element action pane border incomplete during single PD selection, user name/password blue box alignment(SCGCQ02091191) - Issue pertaining to failure notification(SCGCQ02095408) - Fixed: FW upgrade issues with Aero FW files(SCGCQ02097971) - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02108807) - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119031) - Fixed: Cachecade VD creation diaglog doesnt populate Raid levels(SCGCQ02142026) - "Remove drives" option should not come if user is doing RLM from R6 with 3 drives to R5(SCGCQ02184393) - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01512320) - LSA needs to Handle when controller is in safe Mode(SCGCQ01838234) - MRSA : MRSA shows the logout option in drop down menu .(SCGCQ01902913) - LSA 7.9: Unable to enter password while adding mail server authentication.(SCGCQ01933819) - LSA 7.9 :Status error description for schedular operation is not mapped to the proper device ID.(SCGCQ01940978) - WG: NO PD info is shown for foreign configuration(SCGCQ01942159) - WG: Instance Secure Erase is not giving any action indication(SCGCQ01942452) - WG:Remove icon for manually added server not shown in manage server page, Signin should be disabled when login in progress(SCGCQ01960469) - Scheduler API call in not working in standalone mode of installation(SCGCQ01961390) - LSA 7.9 alpha: Error code 69642 is seen when disable/enable unmap operation is performed on Unmap VD.(SCGCQ01963097) - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01969806) - WG: All the events to Vmware are coming as information(SCGCQ01973905) - LSA 7.9: Incorrect critical message displayed for Offline PD.(SCGCQ01979150) - Fixed: Updated curl library for Linux OS(SCGCQ01979794) - LSA 7.9: Re-scan button is disabled after GHS import.(SCGCQ01982953) - LSA 7.9:FDE HDDs are assigned as DHSP for an encrypted OPAL VD(SCGCQ01982973) - Status reports as failed although firmware is updated successfully(SCGCQ01983031) - MR 7.9 PA: LSA Win: 7.9_PA-007.009.007.000 Fails to display JBOD, StorCLI works fine(SCGCQ01994803) - LSA does not show failure or success notification when clear configuration is performed.(SCGCQ01996512) - WG: Instance Validation failed for Event history GET(SCGCQ01998296) - LSA - Selected firmware version displayed as blank during update firmware(SCGCQ02034485) - LSA: Administrators User group is given Read only privileges after adding Users to Administrators group.(SCGCQ02048915) -(SCGCQ02048923) - Client changes for review-30 schema compliance(SCGCQ02062850) - Aero DBU PA2(LSA(SCGCQ02065575) - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070840) - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02084515) - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02094537) - GUI css issues with update firmware panel and snapdump actions(SCGCQ02094845) - Spacing issues seen while converting a drive from JBOD to UG(SCGCQ02095422) - WG:Enclosure ID and Device ID display inconsistency in SS page and CC page, Configure options in SS page alignment issues(SCGCQ02095855) - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02103116) - Capacity sorting is not working in presence of TB drive in the PD list of VD creation.(SCGCQ02107449) - Snap dump trigger time format ends with Z character.(SCGCQ02184362) - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01880101) - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ01880184) - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ01888233) - LSA 7.8: Incorrect VD capacity size displayed during VD creation(SCGCQ01897176) - LSA 7.9: Mismatch in the alignment of server list.(SCGCQ01904368) - Update firmware version link not clickable in Server Landing Page(SCGCQ01905815) - After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01927915) - LSA Client: In Remote Discovery page, "servers" call is being made twice(SCGCQ01932106) - Incorrect tab listener in login page.(SCGCQ01932725) - LSA 7.9: "Personality management" page do not close automatically after launch of "Schedule consistency check" page.(SCGCQ01933812) - Fixed: clear and generate snap dump feature should not be displayed if snap dump is disabled(SCGCQ01936663) - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01937263) - Clear configuration message not indicating about discards pinned cache(SCGCQ01951802) - WG:GUI issues:Controller health text,system message bar,download log, scheduler operation failure & JBOD to UG notifications(SCGCQ01968459) - Fixed: LSA 7.9:In presence of 32 GHSPs, advance configuration option is leading to configurable page on iMR card(SCGCQ01969524) - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ01969611) - LSA_7.9: Status code and description are not clear during Unconfigured Bad to Unconfigured Good operation.(SCGCQ01972681) - WG: JBOD to UG conversion popup does not show error notification in case there is an OS drive, fails with 400ok though(SCGCQ01973688) - WG: Enabling and disabling the alarm multiple times shows error message without error code number(SCGCQ01973701) - LSA Server: Returning wrong status code as return value - Status Code and Description implementation(SCGCQ01974131) - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ01993611) - LSA locate time inaccurate(SCGCQ02038270) - Aero DBU PA2(LSA(SCGCQ02065617) - No response observed when tried to import Foreign LDs which results is reaching MAX LDs(SCGCQ02082982) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102427) - 7.10-LSA: Event ID 457 description ends junk character.(SCGCQ02184221) -(SCGCQ01878801) - LSA 7.9: Incorrect value accepted during PD locate and wrong Icon displayed in IE when compared to Chrome.(SCGCQ01901766) - LSA server profile shows IT-IR storlib versions.(SCGCQ01901771) - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ01901773) - LSA 7.9: Server search list no more displayed if the user press enter or move the cursor.(SCGCQ01905850) - PH10 PA - LSA - Logout option not presented when drop down arrow is clicked(SCGCQ01934763) - WG: Status code description is not proper(SCGCQ01942172) - LSA 7.9: After converting JBOD drives to UG drives, "action successful" message not displayed and incorrect PD actions listed(SCGCQ01949787) - LSA 7.9 alpha:LSA Status code enhancements - Individual operations related issues(SCGCQ01961403) - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ01968407) - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ01973705) - LSA PR (SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562) - WG_7.10: Enclosure location shows blank for the NVME drives(SCGCQ02076920) - LSA - AWB option is coming for CC VD with Rambler card when user try to modify VD properties if CC VD goes offline/degraded(SCGCQ02184389) - WG: Table formatting is not proper in controller console page(SCGCQ01875668) - Fixed: Adding more than 1 vd on a hole & adding more than 1 vds on existing DG fails in LSA(SCGCQ01940161) - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01944435) - Fixed: Download DA/SA server report when downloaded remotely from Gateway(SCGCQ01969625) - MRSA: Enclosure count updated wrong in Server profile page(SCGCQ01976923) - For 7.10 LSA with max VD configuration, with foreign configuration present LSA unable to import or reject or proper message should displayed. Can you please look into this issue.(SCGCQ02184326) - LSA 7.9: Select and un-select button does not work after minimizing the tab(SCGCQ01978952) - Fixed: Blank page shown on trying to login 2nd time VMware using Manage server page(SCGCQ02035380) - LSA : Getting wrong data about max number of PD support for R6 while doing RLM(SCGCQ02184391) - SCGCQ01134787: GUI’s are required to be localized for the following languages: English, French, Italian, German, Spanish, and Japanese(SCGCQ01840448 port of SCGCQ01134787) - Security Standalone requirements for LSA Server code changes(SCGCQ01854924 port of SCGCQ01399720) - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01857649 port of SCGCQ01598200) -(SCGCQ01868298 port of SCGCQ01564366) - Megacell Status Support - Phase2 (Caching and Controller health Status(SCGCQ01869716 port of SCGCQ01598139) - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab(SCGCQ01962269 port of SCGCQ01898255) - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852) - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406) - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964) - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802) - WG: LSA manage link speed pane does not provide any info to user on which port is connected/disconnected(SCGCQ01963971 port of SCGCQ01512320) - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435) - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390) - RWC3 Linux License Agreement and Desktop Shortcut Is for LSI instead of RWC3 (Windows RWC3 is okay(SCGCQ01971208 port of SCGCQ01942985) - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216) - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD(SCGCQ01972651 port of SCGCQ01966687) - Fixed: missing Event description for new events was pausing LSA(SCGCQ01991449 port of SCGCQ01980570) - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02000919 port of SCGCQ01929667) - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02002118 port of SCGCQ01993697) - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007219 port of SCGCQ01929667) - (SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA(SCGCQ02015378 port of SCGCQ01993697) - WG: Enabling or disabling SSD guard fails with error code "1", Description: "SSD Guard Disable Failure "(SCGCQ02016686 port of SCGCQ02009718) - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02030825 port of SCGCQ02006229) - PH11 PA LSA - Attached Drive info not displayed under controller page(SCGCQ02031020 port of SCGCQ02023407) - LSA Client : Trigger and Download Snap Dump from application(SCGCQ02032043 port of SCGCQ01917087) - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state(SCGCQ02032206 port of SCGCQ02021372) - WG: No Action Successful notification shown on Drive erase(single Drive(SCGCQ02032617 port of SCGCQ01941129) -(SCGCQ02034407 port of SCGCQ02030621) -(SCGCQ02034409 port of SCGCQ02030621) - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245) - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035246 port of SCGCQ02034466) - WG:Unable to perform Enable SCSI Unmap operation when DHSP is removed from the VD.(SCGCQ02036726 port of SCGCQ02035226) - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929) - Memory Leak issues LSA Build (7.009.007.00(SCGCQ02042291 port of SCGCQ02006229) - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080) - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611) - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270) - LSA locate time inaccurate(SCGCQ02043619 port of SCGCQ02038270) - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007) - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083) - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184) - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781) - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452) - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress(SCGCQ02044809 port of SCGCQ01973705) - Issues wrt the linux installer script(SCGCQ02044832 port of SCGCQ01879303) - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171) - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078) - No help option available for Megacell option whenever it calls for “Needs Attention” in LSA(SCGCQ02050529 port of SCGCQ02022983) - LSA - Patrol Read maxconcurrentpd count in LSA should be inline with FW(SCGCQ02053882 port of SCGCQ02040516) - LSA 7.9: Incorrect Filter message displayed, wrong message after max vd and multiple grammatical errors in Licence document.(SCGCQ02055506 port of SCGCQ01901773) -(SCGCQ02055834 port of SCGCQ01878801) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055865 port of SCGCQ02035322) - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02057603 port of SCGCQ02003711) - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ02064849 port of SCGCQ01984624) - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067442 port of SCGCQ02045048) - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02070858 port of SCGCQ02070840) - LSA: Read_only_access group users are given administrator privileges(SCGCQ02080158 port of SCGCQ02078614) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322) - Fixed: Calculation to get possible range for RLM(SCGCQ02087354 port of SCGCQ02070841) - Fixed: Calculation to get possible range for RLM(SCGCQ02093538 port of SCGCQ02070841) - Fixed: Allowed Simple config parameters are not displayed(SCGCQ02094990 port of SCGCQ02076799) - LSA is not showing PD Connector information properly with passive backaplane(SCGCQ02096769 port of SCGCQ02096766) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102495 port of SCGCQ02102427) - Application Crash when tried to create a LD with 15 character length(SCGCQ02113222 port of SCGCQ02112041) - LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info.(SCGCQ02119286 port of SCGCQ02119031) - Application Crash when tried to create an LD with 15 character length(SCGCQ02121748 port of SCGCQ02111930) - WG 7.11: Simple configuration fails when multiple vds are created.(SCGCQ02125582 port of SCGCQ02125538) - Configuration options is not getting updated when we change the personality(SCGCQ02154818 port of SCGCQ02124500) - Only 1 drive is displayed although more than 1 drive has opted for Dedicated drive(SCGCQ02154840 port of SCGCQ02113971) - Aero DBU PA5(LSA): Secure jbod option is not shown for the FDE capable jbod drive in LSA(SCGCQ02162725 port of SCGCQ02149233) - LSA service/Nginx service is stopping after few hours and WebGUI is not responding in RHEL 8.0 OS(SCGCQ02172192 port of SCGCQ02151342) - LSA Aero IT: LSA installation with "start from now" option is throwing error code:9098 in event logs.(SCGCQ02172199 port of SCGCQ02121896) - Event ID 610 and 611 are empty(SCGCQ02172244 port of SCGCQ02166100) - Generic LSA w/MRSA backend (Snap 3(SCGCQ01818695 port of SCGCQ01532391) - IML event customization (Mesa Verde(SCGCQ01837799 port of SCGCQ01625911) - Dual Firmware Image Support on Controller Flash for Recovery(SCGCQ01847635 port of SCGCQ01320454) - LSA : Dqueue logs need to be fetched in smaller chunks by the applications(SCGCQ01860906 port of SCGCQ01571368) - SSD WEAR GAUGE Support(SCGCQ01891668 port of SCGCQ01890543) - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915862 port of SCGCQ01905192) - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775) - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617) - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692) - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368) - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01990298 port of SCGCQ01856350) - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01990346 port of SCGCQ01829895) - (SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ02001873 port of SCGCQ01856350) - LSA: LSA Crashes on updating firmware and doing OCR, not able to recover further(SCGCQ02034499 port of SCGCQ02032031) - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926) - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL)(SCGCQ02042097 port of SCGCQ01993099) - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386) - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233) - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598) - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446) - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300) -(SCGCQ02043859 port of SCGCQ01927978) - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407) - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452) - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02055880 port of SCGCQ02035322) - Status reports as failed although firmware is updated successfully(SCGCQ02058472 port of SCGCQ01983031) - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ02081267 port of SCGCQ01838943) - LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab(SCGCQ02084746 port of SCGCQ02078435) - NVMe Drive interface type should be shown as "NVMe" instead of "PCIe"(SCGCQ02100198 port of SCGCQ02096718) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427) - Fixed: Snap dump file(SCGCQ02105149 port of SCGCQ02080184) - WG 7.11:Jbod Locked foreign config details are empty under foriegn configuration operation.(SCGCQ02112529 port of SCGCQ02112203) - WG: LSA incorrectly notifies "Incomplete or Non-Importable foreign configuration found" instead of max supported configuratio(SCGCQ02162724 port of SCGCQ02149353) - WG: LSA shows the same connector for both backplane and enclosure in properties pane(SCGCQ02179358 port of SCGCQ02167855) - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01869701 port of SCGCQ01246226) - Support newly added Sanitize event for cache update.(SCGCQ01869717 port of SCGCQ01740786) - WG: with loop back SMTP Ip, only the test email is received to broadcom mail id, able to add duplicate email id to email tab(SCGCQ01918643 port of SCGCQ01880101) -(SCGCQ01925516 port of SCGCQ01714322) - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234) - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263) - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074) - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume(SCGCQ01970440 port of SCGCQ01752969) - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275) - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01974074 port of SCGCQ01971368) - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466) - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02067299 port of SCGCQ02044922) - RWC3 Windows Readme contains IR3 controllers under supported controllers list(SCGCQ02082904 port of SCGCQ02081038) - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427) - Fixed: R00 max pd limit is changed to be aligned with fw requirement(SCGCQ02116793 port of SCGCQ02108807) - LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1(SCGCQ02118270 port of SCGCQ02108817) -(SCGCQ02154813 port of SCGCQ02142063) - Fixed: parity disk count was missing in algorithm to calculate minimum VD(SCGCQ02154869 port of SCGCQ02139246) - WG: LSA does not update on Clearing the config from server summary page in presence of degraded config(SCGCQ02160137 port of SCGCQ02154073) - LSA - upgrade installshield(SCGCQ02164387 port of SCGCQ02087375) - Download Server Report – change this to Download Support Log and Remove Download Diagnostics(SCGCQ01824401 port of SCGCQ01388152) - LSA No Login (HPE Snap 3 SOW(SCGCQ01840451 port of SCGCQ01512600) - Sanitize Support (HPE SNAP 3(SCGCQ01857424 port of SCGCQ01564367) - IML event customization (Mesa Verde(SCGCQ01868281 port of SCGCQ01625911) - LSA is allowing to delete OS VD.(SCGCQ01923557 port of SCGCQ01873420) - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01942179 port of SCGCQ01937406) - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01962278 port of SCGCQ01952143) - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967919 port of SCGCQ01918692) - WG: Instance validation for PD and Configuration service GET fails with " isSupportedByFW' & 'securityType' was unexpected(SCGCQ01998976 port of SCGCQ01998305) - (SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895) - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02007218 port of SCGCQ01929667) - (SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02053863 port of SCGCQ02035322) - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02062148 port of SCGCQ02035158) - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515) - Fixed: Calculation to get possible range for RLM(SCGCQ02093240 port of SCGCQ02070841) - LSA couldn't install successful in RHEL 8.0 without OpenSLP installed(SCGCQ02105326 port of SCGCQ02103116) - RHEL8- LSA reports warnings during Service restart after reboots, remote discovery page does not list any server other server(SCGCQ02159794 port of SCGCQ02144606) - : Support PCI Slot and Serial Number in(SCGCQ01822600 port of SCGCQ01351434) - MRSA:Default strip size should be 64KB for SSD(SCGCQ01825959 port of SCGCQ01406706) - Change the word data protection to Data Integrity Field(SCGCQ01839302 port of SCGCQ01827434) - Expander support for LSA(SCGCQ01839611 port of SCGCQ01372657) - (SCGCQ01681996: Copy back option should not prompt for already copyback progress PD.(SCGCQ01840438 port of SCGCQ01681996) - Drive capacities displayed should match the HPE drive capacity labels.(SCGCQ01847392 port of SCGCQ01134783) -(SCGCQ01943786 port of SCGCQ01932181) - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806) - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ02000918 port of SCGCQ01929667) - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02012079 port of SCGCQ02000446) - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427) - LSA is using old PDL for send Feedback option(SCGCQ02133579 port of SCGCQ02133392) - WG: Making an offline drive of a DG to online does not work in controller health pane, no POST call for same is initiated(SCGCQ02144596 port of SCGCQ02139321) - (SCGCQ01399721: Hercules :HPE: Security Standalone requirements for LSA Linux 32/64 bit Installer changes(SCGCQ01827380 port of SCGCQ01399721) - Support PCI Slot and Serial Number in Mesa Verde(SCGCQ01839058 port of SCGCQ01349491) - Capacity Unit Changes for VD in LSA Client from GB to GIB(SCGCQ01859426 port of SCGCQ01708968) -(SCGCQ01864209 port of SCGCQ01763927) - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904366 port of SCGCQ01901758) - IML event customization (Mesa Verde(SCGCQ01837623 port of SCGCQ01601601) - Megacell Status Support (SNAP3(SCGCQ01868328 port of SCGCQ01566234) -(SCGCQ01869156 port of SCGCQ01320455) - - WG 7.11:Enable scsi unmap checkbox at advance config page is grayed out when enable/disable operation is performed.(SCGCQ02154812 port of SCGCQ02118865) - Security Standalone requirements for LSA Server code changes(SCGCQ01854929 port of SCGCQ01399722) - Expander support for LSA(SCGCQ01855600 port of SCGCQ01376077) - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01869616 port of SCGCQ01849749) - Capacity Unit Changes for VD in LSA Server(SCGCQ01869745 port of SCGCQ01708881) EnhancementRequests (35) - Enhance Status Code and Status description(SCGCQ01825960) - LSA Internal Status code and Description(SCGCQ01850884) -(SCGCQ01949651) - Branding tool and Health (OS eventing(SCGCQ01960398) - Ubuntu LSA support(SCGCQ02042072) - LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048) - Branding tool and Health (OS eventing(SCGCQ02045972) - API changes for NVMe speed and width changes(SCGCQ02053667) - API changes for linkconfig interface(SCGCQ02053671) - Change the parent directory name to "HPEMRSA" in the windows(SCGCQ02055912) - Implement Changes for LSA Light weight agent On ESXi 64 bit Platform(SCGCQ02066385) - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) - API changes for a better presentation of Atlas to tools(SCGCQ02149380) - Snap Dump ClearAll Method logging event(SCGCQ02157359) -(SCGCQ02162699) - Create an event for DDF config clear failed event.(SCGCQ02173513) - WG: LSA "Feedback" UI enhancements(SCGCQ01401503) - LSA Client : Trigger and Download Snap Dump from application(SCGCQ01917087) - Implemented: Allow user to generate snap-dump in firmware and download it(SCGCQ01917294) - Client: Ubuntu LSA support(SCGCQ02042121) - LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02044922) - 64 Bit SLIR3 library to Support for VMWARE ESXi 6.7+(SCGCQ02048704) - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) - Add new topology device type for Atlas switch(SCGCQ02150637) - LSA need to show complete Serial Number and Model Name for NVMe drives(SCGCQ01920105) - LSA Standalone - enhanced authentication/authorization (Windows(SCGCQ01984624) - SSD WEAR GAUGE Support(SCGCQ01890543) - LSA should upgrade to 1.0.2q (OpenSSL and Nginx(SCGCQ01929667) - 64 Bit SLIT library Support for VMWARE ESXi 6.7+(SCGCQ02019271) - LSA: SSD WEAR GAUGE Support(SCGCQ01890612) - MRSA One Click Support Client support(SCGCQ01949650) - LSA Server: Scheduler changes to fit with latest LSA status code(SCGCQ01857843) - Enhance Status Code and Status description(SCGCQ01868342) - LSA Server: Aero FW simplification - Changes for disable least latency mode(SCGCQ01944689) 005.047.000.000 - Moderate Impact --------------- Defects: -WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01680714) -Fixed: nvme is allowed to mix with sas /sata.(SCGCQ01762948) -WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile.(SCGCQ01747490) -WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline(SCGCQ01752969) -WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod.(SCGCQ01763742) -WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection).(SCGCQ01764794) -WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01737550) -LSA locate time inaccurate.(SCGCQ02038270) -LSA PR SCGCQ01907025: Existing administrator authorization fails with Error code:49: invalid credentials.(SCGCQ02023562) -LSA: Authenticated User group is given Read only privileges after adding Authenticated Users to full_access_groups..(SCGCQ02045735) -LSA: VD actions performed using storcli not reflected under LSA's Virtual drive tab.(SCGCQ02078435) -LSA: Read_only_access group users are given administrator privileges.(SCGCQ02078614) -RWC3 Windows Readme contains IR3 controllers under supported controllers list.(SCGCQ02081038) -Fixed: R00 max pd limit is changed to be aligned with fw requirement.(SCGCQ02108807) -LSA - While doing RLM from R6 to R1, odd number of drives option is coming for R1.(SCGCQ02108817) -LSA wrongly treats "MaxAHCIDev" as "Max SATA supported drives" in profile info..(SCGCQ02119031) - LSA installation failed on SLES15.(SCGCQ01784699 port of SCGCQ01760620) - LSA needs proper message for max config import.(SCGCQ01789100 port of SCGCQ01763411) - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01789156 port of SCGCQ01731931) - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716625 port of SCGCQ01716622) - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup.(SCGCQ01810649 port of SCGCQ01803341) - MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813086 port of SCGCQ01813078) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01816649 port of SCGCQ01686080) - MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01816428 port of SCGCQ01641760) - LSA needs proper message for max config import.(SCGCQ01813925 port of SCGCQ01764977) - C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01828830 port of SCGCQ01321211) - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events.(SCGCQ01826237 port of SCGCQ01761830) - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01851980 port of SCGCQ01851906) - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA.(SCGCQ01851919 port of SCGCQ01841280) - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) - LSA login to ESXi 6.x servers fails in SLES 15 OS..(SCGCQ01880123 port of SCGCQ01876091) - handling the session management.(SCGCQ01892868 port of SCGCQ01829897) - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01891168 port of SCGCQ01889547) - Handling the set text mechanism in client.(SCGCQ01886532 port of SCGCQ01850387) - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01897181 port of SCGCQ01841473) - Fixed: Crash when pressing back button after logout.(SCGCQ01892905 port of SCGCQ01865309) - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01897266 port of SCGCQ01818960) - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) - fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01901767 port of SCGCQ01833469) - Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01901774 port of SCGCQ01866289) - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01898263 port of SCGCQ01802344) - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01901754 port of SCGCQ01827404) - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01897144 port of SCGCQ01817275) - Update the Windows Server 2019 OS name in LSA.(SCGCQ01897178 port of SCGCQ01866322) - Remove un printable characters from LSA log.(SCGCQ01901769 port of SCGCQ01901760) - Server: LSA GUI Not Updating Security Key Info.(SCGCQ01897099 port of SCGCQ01761801) - OPAL drives fail to import when entering wrong security key then right security key after power cycle.(SCGCQ01915861 port of SCGCQ01905192) - [CISCO]LSA shows previously set security key (M3g@raid) during importing secured foreign config JBOD (TCG Enterprise SED).(SCGCQ01921581 port of SCGCQ01878346) - LSA fails to start initialization on EPD if it has DDF.(SCGCQ01921583 port of SCGCQ01849522) - (SCGCQ01921684 port of SCGCQ01841361) - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event.(SCGCQ01921836 port of SCGCQ01876230) - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives..(SCGCQ01904075 port of SCGCQ01893304) - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade..(SCGCQ01904345 port of SCGCQ01901758) - .(SCGCQ01920699 port of SCGCQ01808698) - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01921839 port of SCGCQ01829669) - (SCGCQ01921842 port of SCGCQ01803373SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS) - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) - .(SCGCQ01920924 port of SCGCQ01818618) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01921819 port of SCGCQ01856350) - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,.(SCGCQ01915812 port of SCGCQ01906914) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01829895) - LSA 7.8:Import option is given for the Incomplete foreign VD.(SCGCQ01921678 port of SCGCQ01865420) - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives DESCRIPTION OF ISSUE(SCGCQ01921580 port of SCGCQ01823858) - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) -WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674 ) - LSA Server: Populate the Drive Sector Size while reading the LD MFI command.(SCGCQ01930623 port of SCGCQ01926876) - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes.(SCGCQ01961510 port of SCGCQ01889547) - Summary: Gateway LSA is not responding in SLES 12 64bit(SCGCQ01980553 port of SCGCQ01979137) - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) - Optimize the operation areas of UI to add “on demand” call and increase the performance(SCGCQ01792860 port of SCGCQ01746630) - Add sorter on individual panel's header(SCGCQ01792967 port of SCGCQ01614993) - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793020 port of SCGCQ01761197) - LSA Server: Enhance view server profile(SCGCQ01793119 port of SCGCQ01613889) - Add a way to move from Server / Controller dashboard to Login / Remote Server Discovery Page.(SCGCQ01793314 port of SCGCQ01760616) - LSA Client : GUI User Interface to display snap dump details and download snap dump.(SCGCQ01788693 port of SCGCQ01788622) -GUI Performance improvement by reducing the GUI binary size.(SCGCQ01791174 port of SCGCQ01484572) - WG: Clicking on help links anywhere in LSA page for VMware leads to "404-not found" page.(SCGCQ01791205 port of SCGCQ01594101) - LSA Server: Client Logging(SCGCQ01793221 port of SCGCQ01745790) - Enhance Action menu of individual and group element(SCGCQ01793250 port of SCGCQ01606850)- - Add Select All / Un-Select All option to dashboard tables.(SCGCQ01793004 port of SCGCQ01580899) - SCGCQ01761197: Handle Progress events without initiating further api call from Client.(SCGCQ01793081 port of SCGCQ01761224) - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01798297 port of SCGCQ01745770) - Use scheduler call for heavy operations Part 2.(SCGCQ01792861 port of SCGCQ01746649) - SCGCQ01583133: Inconsistency of login dialog box in Manageserver page and Remote discovery page(SCGCQ01793098 port of SCGCQ01583133) - Fixed: LSA allows the user to attempt a 3 drive RAID6 VD creation (via RAID60).(SCGCQ01798511 port of SCGCQ01687523) - SCGCQ01631835: WG: error log and Access log consume entire OS file system space (6.3 GB and 2.6 GB respectively)(SCGCQ01798635 port of SCGCQ01631835) - LSA: SnapDump Implementation(SCGCQ01788680 port of SCGCQ01786658) - Enhance Properties panel of Individual elements.(SCGCQ01792093 port of SCGCQ01613898) - Handle Progress events without initiating further api call from Client.(SCGCQ01792974 port of SCGCQ01761196) - LSA Client Logging.(SCGCQ01792995 port of SCGCQ01752841) - LSA Client: Enhance view server profile(SCGCQ01793196 port of SCGCQ01613529) - LSA: SnapDump Implementation.(SCGCQ01793838 port of SCGCQ01786658) - (SCGCQ01798366 port of SCGCQ01628367) - Implemented: LSA: Disable Cached IO option during VD creation(SCGCQ01798387 port of SCGCQ01697006) - LSA Server: Optimize the operation areas of UI to add “on demand” call and increase the performance.(SCGCQ01793279 port of SCGCQ01745789) - Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01794950 port of SCGCQ01793057) - SCGCQ01595244: WG: issues pertaining to lsa logs file generation in VMware.(SCGCQ01798451 port of SCGCQ01595244) - Adding filters to the PD and VD table.(SCGCQ01625154 port of SCGCQ01614984) - MRSA Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01798299 port of SCGCQ01731931) - WG: Enclosure position is not shown in Progress bar PD details for any enclosure above position index=1 as well as event logs.(SCGCQ01801670 port of SCGCQ01794642) - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives).(SCGCQ01818637 port of SCGCQ01803743) - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01818638 port of SCGCQ01809413) - Adding filters to the PD and VD table.(SCGCQ01807941 port of SCGCQ01614984) - Implementation of LW Agent Related Back-end changes.(SCGCQ01801403 port of SCGCQ01591705) - Add SCSI Unmap property at PD level.(SCGCQ01813071 port of SCGCQ01732785) - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress).(SCGCQ01818554 por of SCGCQ01680714) - WG: Duplicate PD entires of replace Drive listed in PD list of controller console page on sorting the PD list more than twice.(SCGCQ01803785 port of SCGCQ01794631) - WG: View more properties pane is overlapped by the progress bar if the progress info is in expanded state.(SCGCQ01803986 port of SCGCQ01763142) - MR7.7: Removal of UNMAP support for JBOD.(SCGCQ01813180 port of SCGCQ01813078) - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG.(SCGCQ01818631 port of SCGCQ01803722) - Unable to import foreign secured VDs with different security key.(SCGCQ01818678 port of SCGCQ01670139) - LSA needs proper message for max config import.(SCGCQ01813926 port of SCGCQ01764977) - MR7.6: LSA crashed with a mouse click on VD.( SCGCQ01819577 port of SCGCQ01641760) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01822126 port of SCGCQ01686080) -.(SCGCQ01824435 port of SCGCQ01317424) -.( SCGCQ01827729 port of SCGCQ01808698) - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01837518 port of SCGCQ01802344) - handling the session management.(SCGCQ01841323 port of SCGCQ01829897) - LSA PD slot numbering doesn't not display as ascending order by default(SCGCQ01415337 port of SCGCQ01406115) - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config(SCGCQ01838336 port of SCGCQ01818953) - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config(SCGCQ01838335 port of SCGCQ01817275) - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01837786 port of SCGCQ01745768) - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01838449 port of SCGCQ01818960) - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button.(SCGCQ01839325 port of SCGCQ01737550) - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01845011 port of SCGCQ01841473) - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons(SCGCQ01848661 port of SCGCQ01840475) - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01847352 port of SCGCQ01763742) - LSA Client: Improving visible / working area on elements tab(SCGCQ01839616 port of SCGCQ01837412) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01879301 port of SCGCQ01874487) - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830499 port of SCGCQ01761830) - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01830498 port of SCGCQ01761830) - Drive status not displayed in Other Hardware tab(SCGCQ01855592 port of SCGCQ01849636) - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01874490 port of SCGCQ01866289) - WG:Typo event id : 233, Convert button should get disabled when JBOD to UG Conversion in progress, discrepancy in host icons.(SCGCQ01864285 port of SCGCQ01840475) - Tape drive state is blank when connected with 9400-8E card from LSA drives tab.(SCGCQ01852072 port of SCGCQ01851906) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS..(SCGCQ01869568 port of SCGCQ01829895) - LSA Not allowing to clear/Import foreign configuration..(SCGCQ01860931 port of SCGCQ01849749) - LSA Client : 7.8 Coverity defects fix.(SCGCQ01865174 port of SCGCQ01837314) - Fixed: Auto Span Adjust with having >64 disks is not correct..(SCGCQ01855872 port of SCGCQ01827404) - LSA is allowing to delete OS VD.(SCGCQ01883000 port of SCGCQ01873420) - Implementation of LW Agent Related Back-end changes.(SCGCQ01801314 port of SCGCQ01591705) - LSA is allowing to delete OS VD.(SCGCQ01906734 port of SCGCQ01873420) - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01905909 port of SCGCQ01886563) - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.( SCGCQ01906795 port of SCGCQ01893511) - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01893311 port of SCGCQ01761269) -LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive.(SCGCQ01890993 port of SCGCQ01829669) -.(SCGCQ01914269 port of SCGCQ01906844) - LSA 7.8: Controller actions menu, action successful message are misplaced and Progress bar and event log info overlaps.(SCGCQ01914265 port of SCGCQ01893511) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921950 port of SCGCQ01856350) - IR3: Drive count is 0 and no PDs were listed in Controller console Page--> Drives Tab.(SCGCQ01962269 port of SCGCQ01898255) - WG: After adding an VMware server manually to remote discovery page, the " GO to manage server page is not clickable"(SCGCQ01963211 port of SCGCQ01940852) - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01963213 port of SCGCQ01937406) - MRSA : NO option to go forward while configuring the VD`s if all drives are in JBOD.(SCGCQ01963214 port of SCGCQ01902964) - Clear configuration message not indicating about discards pinned cache(SCGCQ01963766 port of SCGCQ01951802) - when clear drive operation is aborted on foreign Pds, the Pds are seen as UG as well listed under DG(SCGCQ01965222 port of SCGCQ01944435) - Scheduler API call in not working in standalone mode of installation(SCGCQ01965612 port of SCGCQ01961390) - LSA 7.9 alpha:Incomplete foreign found after unlocking the Locked foreign config during the Reconstruction.(SCGCQ01971235 port of SCGCQ01962216) - WG: Enclosure:Slot number is not displaying in Ascending or Descending order, if other columns are clicked first.(SCGCQ01963764 port of SCGCQ01874775) - LSA Client: GWT Popup panels are morphing the GWT fixed panels(SCGCQ01965636 port of SCGCQ01943617) - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01967858 port of SCGCQ01918692) - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971507 port of SCGCQ01971368) - LSA needs to Handle when controller is in safe Mode(SCGCQ01963207 port of SCGCQ01838234) - WG: Memory Leak issue with LSA build : 5.035.000.000(SCGCQ01965387 port of SCGCQ01937263) - LSA Server: LSA needs to Handle when controller is in safe Mode(SCGCQ01967491 port of SCGCQ01949074) - LSA 7.9 alpha:issues pertaining to migration from degraded Unmpa R5 to R0(SCGCQ01971232 port of SCGCQ01966275) - WG: VD creation page does not show VD count and capacity of VD that can be created using unmap drive(SCGCQ01962278 port of SCGCQ01952143) - LSA 7.9 Foreign config Import doesnt work correctly with Raid 1 VD.(SCGCQ01972651 port of SCGCQ01966687) - SCGCQ01993697: MR7.9 Alpha: RWC3 (LSA) Uninstall Error: "Option “-x” is deprecated" w/ Linux RHEL 7.6.(SCGCQ02002118 port of SCGCQ01993697) - (CSETActivity) - LSA 7.9:Clear config is successful when OS Pd and other PDs are in jbod state.(SCGCQ02032206 port of SCGCQ02021372) -.(SCGCQ02034407 port of SCGCQ02030621) - LSA locate time inaccurate(SCGCQ02043617 port of SCGCQ02038270) - Fixed: when SasSata-mixing-policy is set to false vd creation options are not getting populated(SCGCQ02043632 port of SCGCQ01880184) - WG: Instance Secure Erase is not giving any action indication(SCGCQ02044624 port of SCGCQ01942452) - WG: VD options are not getting updated after the expanding the VD on selecting the VD while VD expansion is in progress.(SCGCQ02044809 port of SCGCQ01973705) - LSA 7.9:when multiple Vds are added on the existing DG, there is inconsistency in the Vd name(SCGCQ02044903 port of SCGCQ01978171) - Logical drives are listed in the GUI when all the drives are pulled out(SCGCQ02042290 port of SCGCQ01976929) - Memory Leak issues LSA Build (7.009.007.00)(SCGCQ02042291 port of SCGCQ02006229) - LSA 7.9:LSA Gray page is seen when multiple VDs of multiple DGs are deleted.(SCGCQ02042976 port of SCGCQ01983080) - LSA_7.9: Issue pertaining to PD offline operation on multiple PD's of a VD(SCGCQ02043600 port of SCGCQ01969611) - Fixed: Can't Create 5 VDs R6 using 4 pds with AWB,ARA policy with different strip size(SCGCQ02043629 port of SCGCQ01970007) - Fixed: "All the listed drives cannot be mixed" displayed while creation of R0 with "select all" option.(SCGCQ02043631 port of SCGCQ01979083) - LSA Client: MRSA: Crash when tried to flash corrupt firmware(SCGCQ02043796 port of SCGCQ02043781) - Issues wrt the linux installer script(SCGCQ02044832 port of SCGCQ01879303) - WG: After creating VD from server summary page opens empty JBOD conversion page, issue pertaining sector size in filter(SCGCQ02046361 port of SCGCQ01957078) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ02001873 port of SCGCQ01856350) - Shenandoah_MRSA: Listing SAS SSD drive while trying to migrate an array configured with HDD's.(SCGCQ02042096 port of SCGCQ01976926) - Cacheinit should not issue READ_AFTER_IMPORT dcmd id no foreign pd present.(SCGCQ02042292 port of SCGCQ02038386) - WG 7.8: Dedicatedhotspare and Replace missing drive tables are combined in LSA(SCGCQ02043598 port of SCGCQ01888233) - fixed: LSA doesnt consider Copyback state while counting configured pds.(SCGCQ02043630 port of SCGCQ01979598) - LSA 7.9 alpha:Disable data protection option is seen for non-secured & secured VD in presence of locked foreign PD(SCGCQ02043858 port of SCGCQ01960300) -(SCGCQ02043859 port of SCGCQ01927978) - WG: GUI issues: 404 due to unavailable image, VMware login error notification when server down, FW update notification(SCGCQ02044679 port of SCGCQ01968407) - WG: no success or failure message is shown on updating the drive secuirty key(SCGCQ02044688 port of SCGCQ01970452) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ02001889 port of SCGCQ01829895) - SCGCQ02003711: Add default HTTPS to RWC3(SCGCQ02007520 port of SCGCQ02003711) - fixed: logout of indirect agent causing gateway session to expire(SCGCQ01996636 port of SCGCQ01969806) - MR 7.9 Alpha: readForeignCfg: error reading refPd=c!!! aborting operation(SCGCQ02015391 port of SCGCQ01993611) - LSA Client : Trigger and Download Snap Dump from application(SCGCQ02032043 port of SCGCQ01917087) - WG: No Action Successful notification shown on Drive erase(single Drive), Application Version shown as undefined for VMware(SCGCQ02032617 port of SCGCQ01941129) - LSA 7.9:Send Email functionality of LSA is not working.(SCGCQ02034511 port of SCGCQ01998245) - LSA 7.9:Secure using FDE option is not shown for VD(using OPAL) when Drive security is enabled.(SCGCQ02042097 port of SCGCQ01993099) - Shenandoah_Aero_LSA: LSA crashes while initiating OCR on A0 controller(SCGCQ02043856 port of SCGCQ02000446) - MRSA: Crash when tried to flash corrupt firmware(SCGCQ02045015 port of SCGCQ02040739) - PH11 PA - LSA IT - Copyright info needs to be updated(SCGCQ02035247 port of SCGCQ02034466) - LSA Windows Readme: Update the LSA Windows Read me with the enhanced Silent installation instructions(SCGCQ02053863 port of SCGCQ02035322) - Fixed: WG: Instance validation for Controller Get fails(SCGCQ02070858 port of SCGCQ02070840) - LSA - Set PR properties input values need to be changed for "max PD option for PR concurrently"(SCGCQ02084533 port of SCGCQ02035322) - Fixed: Calculation to get possible range for RLM(SCGCQ02093538 port of SCGCQ02070841) - WG: snapdump downloaded after host triggered snapdump is not in zip file format(SCGCQ02089526 port of SCGCQ02084515) - Fixed: Calculation to get possible range for RLM(SCGCQ02093240 port of SCGCQ02070841) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102571 port of SCGCQ02102427) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02103244 port of SCGCQ02102427) - IP/Hostname discovery is not working through manual discovery for Windows and Linux(SCGCQ02102497 port of SCGCQ02102427) - WG 7.10: LSA crashes when generate snapdump or dowload snap dump operations are performed on direct agent(SCGCQ02099466 port of SCGCQ02094537) EnhancementRequest: -Update candidate drive list for VD creation when UNMAP/FDE etc Exist.(SCGCQ01879211) -Aero None-Mode implementation.(SCGCQ01871350) -Add CTRL_SB_SOFT_SECURE_MODE event to indicate soft secure mode.(SCGCQ01965721) -LSA Client: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog.(SCGCQ02044922) -LSA Server: LDET Q32018 - RRB130 - Enable MR advanced debug dump to ttylog(SCGCQ02045048) -LSA Standalone - enhanced authentication/authorization (Windows).(SCGCQ01984624) - Increase in MR_PD_INFO.name length to 32 characters.(SCGCQ02079068) -Better error message for certain unmap operations.(SCGCQ02111563) - MR Windows IOCTL Error codes to Application added to MR API.(SCGCQ02103183) - API change to support NVMe Passthrough over OOB.(SCGCQ02035295) - API change to support new DCMD for consolidated device list.(SCGCQ02037158) - Customer needs to generate and extract the On-demand based debug data both for MR and iMR..(SCGCQ02000566) - Modification in MR_SNAPDUMP_TRIGGER_TYPE enum value.(SCGCQ02030653) - Reword event log messages as it creates unnecessary panic..(SCGCQ02013675) - Add New Generic OOB API To Read ROC Temp, Drive Temp, Drive Type, Drive Protocol and status through OOB BMC.(SCGCQ01940661) - Add a bit for atomic descriptor capable.(SCGCQ01965047) - Additional details about spare.(SCGCQ02033538) - API changes for Lane Margining.(SCGCQ01921241) - Introduced new controller bit.(SCGCQ01985474) - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change.(SCGCQ02103973) - Driver parameter bit for support of tool box cmd.(SCGCQ02002119) - API change to support new DCMD for consolidated device list.(SCGCQ02016723) - .(SCGCQ01740789) 004.189.000.000 - Moderate Impact --------------- -(SCGCQ01351380) - WG: Physical Drives tab should be aligned in center for Advanced Configuration.(SCGCQ01440777) - Fixed: settings in configuration service API is inconsistent with other applciations(SCGCQ01518134) - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01534444) - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01539326) - LSA Client 7.6: SPAN drives order is not maintained(SCGCQ01539355) - Client: LSA should handle the not empty check for enclousre field for the physicalDevices response(SCGCQ01555968) - IT-FURY-PH16:LSA-4.126.0.0-Fully Populated Enclosure S/N is "NA" and shown correctly after few drive removals.(SCGCQ01563352) - SCGCQ01565134: IT-Ventura-PH7:LSA-4.126.0.0- FW update fails with error "File size Exceeds 16MB".(SCGCQ01565134) - WG : Server detail is getting populated twice when user is using local IP (127.0.0.1(SCGCQ01565327) - WG: During VD Creation on Simple Configuration, Clicking more than Once on the Finish Button is giving a Wrong Message.(SCGCQ01569262) - WG: Copyright info is shown as 2017 instead of 2018(SCGCQ01571088) - WG:Pop Up scroll missing in case there are more number of VDs to add while setting patrol read properties & Schedule CC(SCGCQ01571089) - WG: User is notified to that multiselect PD/VD displays the properties but it is not supported(SCGCQ01571095) - IT-FURY-PH16:LSA-SATA NCQ bit is always shown as disabled(SCGCQ01571261) - LSA is not responding if online state is changed to offline(SCGCQ01571453) - SCGCQ01571863: WG: LSA installation/uninstallation on linux does not notify the user on success or failure(SCGCQ01571863) - Fixed: Windows OS details were reported as VMware details in Manual Search(SCGCQ01571874) - WG: LSA wrapper indicates the progress of operations appears to be clickable while there is nothing user can select from list(SCGCQ01573087) - SCGCQ01575706: WG:LSA installation exits on invalid option for selecting range of LSA events, it asks for retry with options listed again(SCGCQ01575706) - SCGCQ01575999: FURY-PH16:LSA-Model Number is getting truncated for ST3000DM001,Hitachi HDS723020BLA642 models.(SCGCQ01575999) - WG: the string 'status' is displayed multiple times after searching the server for manual addition(SCGCQ01577707) - WG: LSA allows to replace HDD missing drive with SSD UG drive, fails with Partial Success.0 Successful;1 Failed notification(SCGCQ01577769) - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01578248) - LSA Server: Removal of Additional Carriage Returns and Line feeds in tty log file(SCGCQ01579290) - WG: Error message on a failed VD creation is displayed outside the allocated space(SCGCQ01586721) - SCGCQ01588880:(SCGCQ01588880) - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01590450) - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01595641) - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01601386) -(SCGCQ01628332) - fixed: Advanced Configuration is grayed out when there are 2 jbods available in the system.(SCGCQ01631267) - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01669558) - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01675460) - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01681070) - WG: LSA 7.7 PA2 Not able to create RAID 00 VDs on iMR Ventura controller(SCGCQ01683638) - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01683938) - During migration from r0(opal drives and non-secured) to r1, Add Pd list does not list the available drives (Greater/same si(SCGCQ01687072) - WG: Issues pertaining to searching of the server : manual discovery in list view & GUI issues in the manual discovery panel(SCGCQ01687117) - MR7.7_LSA: Unable to convert JBOD to UG when filesystem is present(SCGCQ01697980) - LSA Linux doesn't have latest storelib(SCGCQ01713580) - WG MR 7.7 PA2: LSA allows to add FDE and OPAL drives to create Encrypted volume(SCGCQ01721222) - Server: LSA GUI Not Updating Security Key Info(SCGCQ01761801) - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01761830) - Fixed: nvme is allowed to mix with sas /sata(SCGCQ01762948) - SCGCQ01763132: LSA: Alert Configuration response contains unsupported character(SCGCQ01763132) - Foreign Config preview should show the VD details also(SCGCQ01788639) - LSA Opal: RLM mixing for Opal SSC and Enterprise shouldn't be allowed when enableFDETypeMix=0(SCGCQ01790063) - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) - compilation error in server(SCGCQ01817434) - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01841473) - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856350) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) - WG: LSA shows incorrect popups while making the drive from offline to online & vice versa(SCGCQ01922610) - LSA - Not able to import other foreign configs if user have SED drive which is in foreign(SCGCQ01937406) - In JBOD personality LSA service getting stopped when user change JBOD to UG(SCGCQ01971368) -(SCGCQ01542415) - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01552654) - Correcting the library version display, ini file contents and also the readme files contents.(SCGCQ01561849) - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01564526) - SWR: Device ID is not displayed in LSA.(SCGCQ01564621) - MR/IR: Controller Device ID value mismatch in LSA(SCGCQ01564622) - WG:LSA and web server port have references of SLIM and nignx in notification if invalid ports are given during LSA installatn(SCGCQ01571099) - WG: Issues pertaining to replace drive confirmation popup(SCGCQ01573101) - Security related information should not be displayed in IR/IT for LSA(SCGCQ01577891) - LSA allows user to assgin a 512 B drive as replacement to 4k missing drive in a DG(SCGCQ01591175) - SCGCQ01593058: Add non printable character support for sata pd product id display(SCGCQ01593058) - Add a provision to indicate VMware/NonVmware server in Manual Discovery Panel(SCGCQ01600706) - LSA WG FURY IT: UEFI image download is failing in LSA(SCGCQ01616545) - LSA 7.6 Server: LSA is showing the option for PD:"Undo Prepare For Removal", when the DG is in TR state(SCGCQ01618243) - Not able to create secure VD with latest MR 7.7 LSA 177.000.000-SCGCQ01664972 but OK with previous version(SCGCQ01665121) - Error observed while adding Windows gateway server in through manual discovery(SCGCQ01675601) - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01677101) - LSA MR7.7 PA2: Previously cleared configuration is seen in presence of OPAL foreign drive in Jbod Mode.(SCGCQ01685488) - WG MR7.7 PA2:Once the 69639 error code is seen in LSA, performing every valid operation fails until manual refresh is perfo(SCGCQ01686013) - WG MR 7.7:There is no import option for GHS Foreign device in LSA(SCGCQ01698105) - Fixed: LSA handle count increase was observed(SCGCQ01713154) - Add physical Drives page is not consistent across (Advanced Configuration and Modify drive Group(SCGCQ01716606) - LSA: Handle Opal drive scenario for Hotspare and replace drive(SCGCQ01719043) - LSA client: Add support to show incompatible profiles details(SCGCQ01727270) - Add SCSI Unmap property at PD level(SCGCQ01732785) - WG MR 7.7 Alpha:Foreign configuration pane does not show details for foreign dedicated hotspare drive.(SCGCQ01745770) - WG:[intermittent] LSA page goes blank if we click on Drive tab and then immediately click on view serer profile(SCGCQ01747490) - WG MR 7.7 alpha:Lsa does not update the PD(part of r0 volume) status once the PD is made online from offline.(SCGCQ01752969) - [CISCO][TR]"Clear Transport Ready" option on rebuild LD should be removed or greyed out in LSA(SCGCQ01753229) - MR LSA 7.7 : When user has flashed the controller FW for IT card, reboot system message is disappearing within few seconds(SCGCQ01761269) - WG MR 7.7 al:LSA allows to create simple configuration in presence of Unconfigured bad drive and rest of the drives in jbod(SCGCQ01763742) - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813078) - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01833469) - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01838943) - WG: Software licensing agreement for linux RWC3 build is of Generic Channel(SCGCQ01886563) - WG: LSA services crashes while adding the manually discovered VMware server to the manage server list(SCGCQ01918692) -(SCGCQ01534450) - LSA needs to change "Error code" : 86017, Description:Operation failed because of a resource reservation error" to proper mes(SCGCQ01556013) - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01581943) - SCGCQ01582139: MR7.6_LSA: Enclosure ID and Device ID is shown blank in LSA event logs(SCGCQ01582139) - WG: LSA Page auto scrolls down with scheduler wrapper going out of focus. LSA page would now be only half transparent(SCGCQ01586697) - PH7 LSA WG Ventura: Sorting the drives on the basis of Device ID is not working fine(SCGCQ01587630) - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01593855) - WG: Instance validation failed for controller GET(SCGCQ01601458) - WG: Minor text changes to be made in user information when no rows are selected in PD tab / DG tab / other hardware tab(SCGCQ01601656) - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01615856) - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01638193) - SCGCQ01680714: WG:Memory leak issues when the system is not idle ( Running the GUI suite when the memory leak test is in progress(SCGCQ01680714) - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01685449) - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01686024) - Instant Secure Erase does not work in VMware when schedule is enabled(SCGCQ01686028) - MR7.7_LSA: Error code:0 is observed when driver security is changed in LSA(SCGCQ01686050) - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716622) - fixed: max pd is a bigger number than the actual allowed max pd per raid level(SCGCQ01746200) - WG MR 7.7 alpha: LSA displays wrong connector & path info for drives when enclosure is connected in wide port (x8 connection(SCGCQ01764794) - WG: gateway system is not discovering systems with different web port number in remote discovery page.(SCGCQ01788630) - LSA does not update the VD status when Migration is performed from r5(3drives)to r1(2drives)(SCGCQ01803743) - LSA 502 Bad gateway is seen when Prepare for removal is performed on 5 drives at a time.(SCGCQ01809413) - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) - fixed: Info "1920 more drives can be added" need to change in LSA(SCGCQ01827401) - The display wrong location in page(SCGCQ01836732) - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01355833) - WG: Changing the drive security key with invalid authentication key results in notification that is not in format(SCGCQ01573090) - WG: Raid 00 DG having missing drives Span list dissapears when user tries to sort the drives based on capacity(SCGCQ01577833) - MR 7.7: LSA did not allow to pick all SED/FDE but OK to pick one by one when create secure VD(SCGCQ01629062) - SCGCQ01718994: LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01718994) - When there is pending personality, do not allow behavior Mode change, GUI refresh issue(SCGCQ01731312) - Assign DHS is not showing any message in failure case(SCGCQ01732485) - To enable the Alarm user has to click on the bottom of checkbox(SCGCQ01740783) - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01818960) - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives(SCGCQ01850008) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) - LSA needs to convert "Error Code:69637. Descrption:Partial Success.0 Successful;1 Failed" into a readable message.(SCGCQ01533554) - WG: change Behavior Mode From JBOD to None is Not Working until closing the window(SCGCQ01635541) - WG MR7.7PA2:In Jbod mode after first reboot and after converting Jbod to UG, advance configuraton leads to Jbod table.(SCGCQ01683001) - MR 7.7 PA2: LSA does not refresh DG icon when PDs are made offline to online and visa versa.(SCGCQ01686029) - WG MR 7.7 PA2:Encrypted Opal drive VD supports the Opal drive replacement with FDE drive(SCGCQ01697265) - WG: JBOD conversion popup appears multiple times after converting all the drives to UG and clicking on Continue button(SCGCQ01737550) - MR 7.7 alpha: LSA displays raid 1 as raid 1E when created using 4 drives.(SCGCQ01764771) - SCGCQ01564386: IT-FURY-PH16:Drives are not listed under Enclosures ( "0" drives) under other Hardware if connected in Multipath.(SCGCQ01564386) - Coverity Defect fix in 7.7 Stream(SCGCQ01682365) - WG MR 7.7:Invalid Temperature is displayed for OPAL drives.(SCGCQ01714415) - Client changes for defect SCGCQ01629703(SCGCQ01714659) - MR7.7_LSA: After disabling PR, PR properties shows next scheduled time(SCGCQ01718119) - LSA does not give expand option to perform OCE when one among 2vds is deleted under a DG(SCGCQ01803722) - LSA is not locating all drives correctly(SCGCQ01924674) - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01515496) - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01563343) - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01629574) - Fixed: Show Advanced Config menu only if Unconfigured UG is present(SCGCQ01629703) - WG: Readme shows wrong Version of LSA in html\files\LSA_ReadMe\LSA_Readme(SCGCQ01822525) - SCGCQ01822561: WG: Changed LSA port is not listed after Direct agent installation on Rhel(SCGCQ01822561) - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01866289) - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) - Making rebuild drive offline lsa gets 404.(SCGCQ01564627 port of SCGCQ01542412) - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01564633 port of SCGCQ01562368) - LSA Crashes after clicking on foreign configuration(SCGCQ01564739 port of SCGCQ01545262) - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs.(SCGCQ01564943 port of SCGCQ01534444) - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565025 port of SCGCQ01504080) - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01565116 port of SCGCQ01555955) - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade(SCGCQ01566088 port of SCGCQ01562368) - WG: No success or failure notification is shown on enabling the JBOD drive security(SCGCQ01566435 port of SCGCQ01511274) - SCGCQ01545384: Installation of LSA with LWM option is showing installation_type = 0, in the LSA.conf file(SCGCQ01567110 port of SCGCQ01545384) - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569267 port of SCGCQ01504080) - Making rebuild drive offline lsa gets 404.(SCGCQ01569465 port of SCGCQ01542412) - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01569474 port of SCGCQ01539349) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01569949 port of SCGCQ01563340) - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01570203 port of SCGCQ01550970) - Enclosure's physicaldevices URI getting failed with 405 error(SCGCQ01589492 port of SCGCQ01523122) - Label of the user menu drop down should change reinforcing that selection worked.(SCGCQ01597876 port of SCGCQ01493942) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01599402 port of SCGCQ01563340) - Version changes for LSA 4.129 common project(SCGCQ01601148 port of SCGCQ01601146) - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601603 port of SCGCQ01598515) - LSA: Warning Message needs to be changed when there is Controller firmware update failure(SCGCQ01604992 port of SCGCQ01564526) - MR7.6_LSA: No Foriegn configuration details is shown in LSA(SCGCQ01605344 port of SCGCQ01581943) - fixed: logout causing unexpected behavior during end cim connection for vmware systems(SCGCQ01609343 port of SCGCQ01578248) - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page.(SCGCQ01614982 port of SCGCQ01355833) - IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3(SCGCQ01616555 port of SCGCQ01595641) - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01617930 port of SCGCQ01401460) - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01628354 port of SCGCQ01504080) - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01634072 port of SCGCQ01473733) - WG: few of the alert params have the missing controller ID tag for the events(SCGCQ01635756 port of SCGCQ01625923) - LSAServer: Use scheduler call for heavy operations for performance improvement - PD Operations(SCGCQ01635765 port of SCGCQ01514283) - WG: though the hotspare button will be disabled after adding VD for a Raid 1 DG, the hand cursor button appears(SCGCQ01635778 port of SCGCQ01626738) -(SCGCQ01639457 port of SCGCQ01599526) - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01685343 port of SCGCQ01641760) - Raid 1 Volume creation using 4 drives is displayed as Raid 1E(SCGCQ01686231 port of SCGCQ01686106) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687172 port of SCGCQ01686080) - When we try to modify the Unmap SCSI Unmap enabled feature via LSA it should give the reboot server message(SCGCQ01697468 port of SCGCQ01683941) - LSA fails to flash GPMR2 package 50.1.0-1048 on top of MR 7.6 package 50.6.0-1255 on first try-it is successful on 2nd try(SCGCQ01697485 port of SCGCQ01680521) - LSA not showing the proper time stamp in the schedule PR page(SCGCQ01698028 port of SCGCQ01677008) - WG: LSA page doesnt show any notification on time consuming response operations,would lead to user redoing same again(SCGCQ01719179 port of SCGCQ01515496) -(SCGCQ01733306 port of SCGCQ01721811) - Fixed: LSA handle count increase was observed(SCGCQ01742153 port of SCGCQ01713154) - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01747012 port of SCGCQ01745768) - Server schema validation is failing(SCGCQ01764913 port of SCGCQ01619401) - Enclosure Location :Internal for back plane needs to be changed to "NONE" as part of new schema-24(SCGCQ01764928 port of SCGCQ01638193) - LSA installation failed on SLES15(SCGCQ01784699 port of SCGCQ01760620) - LSA needs proper message for max config import(SCGCQ01789100 port of SCGCQ01763411) - Cannot use Special Characters in Domain Name for LSA Login(SCGCQ01789161 port of SCGCQ01745768) - WG: LSA allows user to replace a drive of a DG with drive on which drive clear is already in progress, GUI issues in popup(SCGCQ01810649 port of SCGCQ01803341) - MR7.7: Removal of UNMAP support for JBOD(SCGCQ01813086 port of SCGCQ01813078) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01816649 port of SCGCQ01686080) - C480-M5: LSA downloaded event log needs better decoding(SCGCQ01828830 port of SCGCQ01321211) - LSA-4.1 : Array details are shown in LSA for the partial foreign config .(SCGCQ01850405 port of SCGCQ01818828) - Tape drive state is blank when connected with 9400-8E card from LSA drives tab(SCGCQ01851980 port of SCGCQ01851906) - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01860933 port of SCGCQ01849749) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880125 port of SCGCQ01874487) - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap(SCGCQ01897266 port of SCGCQ01818960) - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online" .(SCGCQ01898344 port of SCGCQ01838943) - fixed: LSA fails to create RAID 10 with large number of drives(SCGCQ01901767 port of SCGCQ01833469) - Fixed: unblock LSA login on ESXi 6.7 U1(SCGCQ01901774 port of SCGCQ01866289) - OPAL drives fail to import when entering wrong security key then right security key after power cycle(SCGCQ01915861 port of SCGCQ01905192) - [CISCO]LSA shows previously set security key (M3g@raid(SCGCQ01921581 port of SCGCQ01878346) - LSA fails to start initialization on EPD if it has DDF(SCGCQ01921583 port of SCGCQ01849522) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01921592 port of SCGCQ01829895) -(SCGCQ01921684 port of SCGCQ01841361) - MR7.8 Foreign import from 7.7 to 7.8 with unmap VD and non unmap DHS does not alert user with a critical message/event(SCGCQ01921836 port of SCGCQ01876230) - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura(SCGCQ01538488 port of SCGCQ01473733) -(SCGCQ01564591 port of SCGCQ01515389) - WG: System display uniformity is not there in GUI (Remote server discovery(SCGCQ01567177 port of SCGCQ01553588) - Client: Handle Enable/Disable style for search Button(SCGCQ01567216 port of SCGCQ01539573) - LSA Crashes after clicking on foreign configuration(SCGCQ01567307 port of SCGCQ01545262) - Manual discovery of servers(SCGCQ01569264 port of SCGCQ01539471) - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01569569 port of SCGCQ01504080) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n(SCGCQ01570076 port of SCGCQ01563340) - Converting the JBOD Pds to Unconfigured good PD during VD creation VD creation(SCGCQ01597581 port of SCGCQ01518204) - Manual discovery of servers(SCGCQ01600837 port of SCGCQ01539471) - LSA 7.6:In gateway LSA, none of the servers are listed except Self server in Remote server discovery page in Rhel 7.4(SCGCQ01615020 port of SCGCQ01552654) - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server(SCGCQ01615042 port of SCGCQ01601386) -(SCGCQ01633836 port of SCGCQ01599526) - Fixed: Gateway crash when DA is logged in greater than max logins(SCGCQ01635183 port of SCGCQ01593855) - Use schedular call for heavy operations for performance imporvement(SCGCQ01635665 port of SCGCQ01506032) - Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01635761 port of SCGCQ01518113) - JBOD Mode : WG: Even after clicking Convert JBOD the JBOD conversion page does not refresh with updated list(SCGCQ01635784 port of SCGCQ01617721) - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676612 port of SCGCQ01670094) - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time(SCGCQ01676732 port of SCGCQ01670094) -(SCGCQ01685548 port of SCGCQ01685009) - LSA Wont display foreign data when enclosure information in not populated properly(SCGCQ01686054 port of SCGCQ01685449) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config(SCGCQ01687173 port of SCGCQ01686105) - fixed: WG: managing the manually added server fails : windows(gateway(SCGCQ01697195 port of SCGCQ01682360) - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716641 port of SCGCQ01716622) -(SCGCQ01718985 port of SCGCQ01698211) - Security Key Confirm Text box should not accept the copy of anything(SCGCQ01788477 port of SCGCQ01629574) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01880123 port of SCGCQ01876091) - handling the session management(SCGCQ01892868 port of SCGCQ01829897) - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01898263 port of SCGCQ01802344) - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01901754 port of SCGCQ01827404) - LSA 7.8:LSA provides Instant secure erase option for Locked UG BAD drives.(SCGCQ01904075 port of SCGCQ01893304) - LSA 7.8: Unable to launch LSA from different web server port after LSA upgrade.(SCGCQ01904345 port of SCGCQ01901758) -(SCGCQ01920699 port of SCGCQ01808698) - LSA: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01921839 port of SCGCQ01829669) - SCGCQ01803373: WG: LSA service crashes on downloading support logs in case of Linux 64 bit OS(SCGCQ01921842 port of SCGCQ01803373) - WG: LSA does not notify user on OS VD present if multiple VDs are selected and with non OS VD is selected first(SCGCQ01928961 port of SCGCQ01926674) - LSA Server: Populate the Drive Sector Size while reading the LD MFI command(SCGCQ01930623 port of SCGCQ01926876) - Schema -23 is not upto date with the Mark/Replace Missing feature(SCGCQ01557738 port of SCGCQ01539349) - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive.(SCGCQ01564629 port of SCGCQ01550970) - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message(SCGCQ01564682 port of SCGCQ01547992) - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01569579 port of SCGCQ01514206) - Support from LSA back-end to allow JBODs to be converted to UG for advance VD creation(SCGCQ01597602 port of SCGCQ01519271) - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01670841 port of SCGCQ01629821) - [CISCO][TR] LSA fails to show DG in TR state after system reboot -storCLI OK(SCGCQ01676281 port of SCGCQ01615856) - Server schema validation is failing(SCGCQ01676389 port of SCGCQ01619401) - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space(SCGCQ01679003 port of SCGCQ01563343) - Secure Jbod unlock is not showing the proper error message in LSA(SCGCQ01680728 port of SCGCQ01677101) - LSA taking more time to discover VMWare servers(SCGCQ01681092 port of SCGCQ01681069) -(SCGCQ01697478 port of SCGCQ01685009) - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode(SCGCQ01716625 port of SCGCQ01716622) -(SCGCQ01718980 port of SCGCQ01698211) -(SCGCQ01749087 port of SCGCQ01698211) - Modify Properties option is enabled for VDs which are part of Transport Ready Drive Group(SCGCQ01764894 port of SCGCQ01763056) - Fixed: Delay in updating drive count in LSA due to slowness in asynchronous events(SCGCQ01826237 port of SCGCQ01761830) - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation(SCGCQ01837378 port of SCGCQ01833791) - SCGCQ01841280: Before importing foreign CC VD, model number of SSD is not coming in LSA(SCGCQ01851919 port of SCGCQ01841280) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01856730 port of SCGCQ01856350) - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01891168 port of SCGCQ01889547) - CC VD creation option is coming in LSA when the CC VD (SATA SSD(SCGCQ01897144 port of SCGCQ01817275) - Update the Windows Server 2019 OS name in LSA(SCGCQ01897178 port of SCGCQ01866322) -(SCGCQ01920924 port of SCGCQ01818618) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921819 port of SCGCQ01856350) - LSA 7.6 Client: Cosmetic replace drive selection issue(SCGCQ01566455 port of SCGCQ01539347) - SCGCQ01539326: [UNMAP]MR7.6 Unmap/WriteSame: AEN's are not generated when unmap capability gets disabled or enabled on a VD.(SCGCQ01567176 port of SCGCQ01539326) - WG: Alignment in Remote Server Discovery page changes when it is in List view and filtered with any one of the OS type.(SCGCQ01567193 port of SCGCQ01471834) - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569137 port of SCGCQ01538253) - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01569138 port of SCGCQ01538253) - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01569488 port of SCGCQ01540821) - Client:Allow individual element's properties download - VD / PD / DG / BBU / Server profile(SCGCQ01597592 port of SCGCQ01518206) - WG:Once the Controller is moved from Raid to JBOD all the drives are counted as drive group(SCGCQ01601608 port of SCGCQ01598515) - WG: empty details for policy change displayed in events "Previous = Current Write Policy: Now = Current Write Policy:"(SCGCQ01635759 port of SCGCQ01625912) - WG:On changing behavior from None to JBOD and moving to Controller Console page, LSA page redirects to Personality management(SCGCQ01635779 port of SCGCQ01629821) - TR VD should be excluded from the PR VD list(SCGCQ01677110 port of SCGCQ01677062) - Implemented: Allow mixing of nvme drives to be mixed with SATA/SAS drives(SCGCQ01697042 port of SCGCQ01697026) - Hercules : Snap 4 : Alpha : LSA provides option of performing an RLM operation on Degraded VD, which fails(SCGCQ01789156 port of SCGCQ01731931) - MR7.6: LSA crashed with a mouse click on VD(SCGCQ01816428 port of SCGCQ01641760) - Handling the set text mechanism in client(SCGCQ01886532 port of SCGCQ01850387) - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016(SCGCQ01897181 port of SCGCQ01841473) - WG: LSA provides option of Secure using FDE if non encrypted r1 VD with secure drive is assigned with DHSP,(SCGCQ01915812 port of SCGCQ01906914) - LSA 7.8:Import option is given for the Incomplete foreign VD(SCGCQ01921678 port of SCGCQ01865420) - LSA is allowing to delete OS VD.(SCGCQ01921689 port of SCGCQ01873420) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon(SCGCQ01921919 port of SCGCQ01856350) - WG: VMware server takes too long to discover in remote discovery page : nearly 20 minutes(SCGCQ01961510 port of SCGCQ01889547) - Not able to set max no of PD using set patrol read properties in LSA/Storcli(SCGCQ01697480 port of SCGCQ01681070) - Add Virtual Drive option is available for DGs with Transport Ready feature set(SCGCQ01764885 port of SCGCQ01763052) - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in(SCGCQ01828400 port of SCGCQ01538253) - Fixed: Crash when pressing back button after logout(SCGCQ01892905 port of SCGCQ01865309) - Remove un printable characters from LSA log(SCGCQ01901769 port of SCGCQ01901760) - LSA does not show Secure Erase option for foreign secured JBOD drive-CLI works(SCGCQ01920701 port of SCGCQ01916249) - WG: LSA allows to remove the data drive during the RLM from single drive R0 and allows migrate to R0 with no drives(SCGCQ01921580 port of SCGCQ01823858) - Modify the LSA Health Algorithm to consider the Blocked VD(SCGCQ01565119 port of SCGCQ01504080) - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4(SCGCQ01569761 port of SCGCQ01555955) - Unable to import foreign secured VDs with different security key(SCGCQ01731357 port of SCGCQ01670139) - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01794950 port of SCGCQ01793057) - Activity to check-in Auto-BST files to 7.8 streams(SCGCQ01817915 port of SCGCQ01793057) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) - Server: LSA GUI Not Updating Security Key Info(SCGCQ01897099 port of SCGCQ01761801) - LSA WG Fury IT: Controller type is showing as IR for IT card(SCGCQ01564631 port of SCGCQ01540821) - LSA Schema 24: replace-missing get operation needs to follow the schema(SCGCQ01679329 port of SCGCQ01675460) - LSA shows wrong diskgroup info when you have foreign PD(SCGCQ01698150 port of SCGCQ01590450) - LSA needs proper message for max config import(SCGCQ01813925 port of SCGCQ01764977) - UG LSA 7.8 PA2:Incomplete foreign VD is seen when Clear foreign config is performed.(SCGCQ01851155 port of SCGCQ01849681) - Fixed: Advance configuration operation should be greyed out if max pds are already configured(SCGCQ01922015 port of SCGCQ01850445) - I/Os are not recover after drives pull for DHSP to rebuild.(SCGCQ01564737 port of SCGCQ01514206) EnhancementRequests: - Add "Replace Missing Drive" feature to LSA(SCGCQ01399204) - Part 2 of 2: Support TCG Opal 2.0 via SafeStore for VDs and SystemPD (Legacy JBOD) in RAID Mode and JBOD/SDS Modes(SCGCQ01599762) -(SCGCQ01740789) - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) - MR API changes to support EKMS over OOB(SCGCQ01874035) - Add new error code for tampered or invalid controller(SCGCQ01885686) - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) - Add secure boot key update complete event(SCGCQ01928254) - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) - Add "Replace Missing Drive" feature to LSA(SCGCQ01399205) - Manually add server details to the list of servers(SCGCQ01539514) - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01740787) - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group.(SCGCQ01401460) - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746609) - Manual discovery of servers(SCGCQ01539471) - Change tools to report drives attached to HBAs as JBOD instead of UGOOD(SCGCQ01802344) -(SCGCQ01599763) - UNMAP/TRIM/WRITESAME for NVMe devices for R0/EPD/JBOD(SCGCQ01746608) 004.069.000.000 - Moderate Impact --------------- Defects (20) -.(SCGCQ01753405) - Server: LSA GUI Not Updating Security Key Info.(SCGCQ01761801) - CC VD creation option is coming in LSA when the CC VD (SATA SSD) is in foreign config.(SCGCQ01817275) - Fixed: Auto Span Adjust with having >64 disks is not correct.(SCGCQ01827404) - Lenovo 18D - missing display "Uninstall LSA" shortcut in the "Start Menu" under windows2016.(SCGCQ01841473) - LSA Not allowing to clear/Import foreign configuration.(SCGCQ01849749) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856350) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01874487) - seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619) - Not able to create PRL11 CC VD (using 4 SATA SSD PD) from LSA webGUI.(SCGCQ01822209) - fixed: LSA fails to create RAID 10 with large number of drives.(SCGCQ01833469) - LSA does not ask for user confirmation for possible Data corruption while changing Pd state from "offline->online".(SCGCQ01838943) - LSA : Stale entries are coming in DG tab when the VD (failed) is in foreign config.(SCGCQ01818953) - fixed: Info "1920 more drives can be added" need to change in LSA.(SCGCQ01827401) - The display wrong location in page(SCGCQ01836732) - LSA : GUI tab alignment is not coming proper after user initiates manual learn cycle for Supercap.(SCGCQ01818960) - LSA:fw error "BAIL_OUT at line 2909",FDE drive filtering for creating Encrypted RAID0 volumes lists non-FDE drives.(SCGCQ01850008) - LSA login to ESXi 6.x servers fails in SLES 15 OS.(SCGCQ01876091) - Fixed: unblock LSA login on ESXi 6.7 U1.(SCGCQ01866289) - Linux system is getting IPV6 by default & it is not taking private IPV4 range(10 series) in LSA main page.(SCGCQ01817305) - Security Key Confirm Text box should not accept the copy of anything.(SCGCQ01788477 port of SCGCQ01629574) - SCGCQ01856350: LSA_18D installed in SLES15 OS, the icon in LSA shows as Redhat icon.(SCGCQ01856730 port of SCGCQ01856350) - The LSA is failing to take into account current USED PDs from another configured VD during next VD creation.(SCGCQ01837378 port of SCGCQ01833791) - SCGCQ01538253: LSA-4.055.0.0: IT-Cutlass- LSA Event logs is missing Enclosure ID's and slot-36 is shown to be present in.(SCGCQ01828400 port of SCGCQ01538253) - Activity to check-in Auto-BST files to 7.8 streams.(SCGCQ01817915 port of SCGCQ01793057) - SCGCQ01829895: LSA uninstaltion is not working in SLES15 OS.(SCGCQ01869566 port of SCGCQ01829895) EnhancementRequests (20) - RTTrace API Changes.(SCGCQ01745568) - API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266) - RTTrace Enable/Disable API changes.(SCGCQ01830211) - Criteo: API changes reversal.(SCGCQ01760512) - Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538) - Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062) - Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153) - Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319) - Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724) -.(SCGCQ01818580) - Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135) - API change to provide learn complete timestamp.(SCGCQ01845269) - Added Support for Triggering SnapDump.(SCGCQ01848759) - Add secure boot support.(SCGCQ01792416) - Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424) - Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686) - [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480) - Added new events for unmap policy changes.(SCGCQ01871912) - API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150) - Change tools to report drives attached to HBAs as JBOD instead of UGOOD.(SCGCQ01802344) 004.062.000.000 - Moderate Impact -------------- fixed: Nginx versions since 0.5.6 up to and including 1.13.2 are vulnerable to integer overflow vulnerability in nginx range filter module resulting into leak of potentially sensitive information triggered by specially crafted request.https://nvd.nist.gov/nvd.cfm?cvename=CVE-2017-7529. Defects (109) - LSA server report for iMR Inv controller displays dedicatedHotSparePerDriveGroup is 0 under "maxLimit".(SCGCQ01375788) - SCGCQ01393056: Enclosure ID is coming up as null in LSA.(SCGCQ01393056) - WG: Error message not fitting inside the message box in "Enable Drive Security" page..(SCGCQ01442477) - WG: Issues pertaining to 'Make JBOD Secure' Pop up.(SCGCQ01446801) - PerfImp: Don't handle SLIM_EVT_EXCEEDS_MAX if there is no event requires complete refresh.(SCGCQ01447165) - WG: UI Pattern in "Virtual Drive Settings" is not uniform while creating and modifying VD properties..(SCGCQ01447697) - WG: "Change" button shown as disabled when user tries to change Behavior mode..(SCGCQ01450713) - DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571) - WG: success message box for "change personality" does not have proper border.(SCGCQ01453980) - WG: Event Log table headers needs space - Cosmetic.(SCGCQ01460053) - WG: Notification after saving the changes in "Manage Power Save Settings" needs cosmetic change..(SCGCQ01460078) - Requested personality field is not updated for Ventura.(SCGCQ01465642) - API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754) - WG: Tooltip for help link in "Remote Server Discovery" page is not displayed..(SCGCQ01471842) - WG: "Available UG drives" form is shown blank when "Type" is selected from ALL to any other drives..(SCGCQ01472186) - WG: LSA showing inappropriate message after securing a DG using FDE security..(SCGCQ01472201) - Buttons are inconsistent in Email Settings page of LSA.(SCGCQ01472752) - Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.().(SCGCQ01474461) - MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01482320) - During Advanced Vd Creation PD selection order is not maintained by the client.(SCGCQ01498969) - Display the ROC temperature in Fahrenheit as well along with Celsius.(SCGCQ01504619) - WG: Hand mouse pointer is used in " Background Process progress " window , where it shows the name of background operations..(SCGCQ01505999) - [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045) - WG: Caps letter is expected in Settings for Alert settings successful and restore default value successful message..(SCGCQ01509253) - WG: Sorting of drives by model number does not work for JBOD drives.(SCGCQ01511247) - Do not allow the user to manage Personality Panel if set personalty is not supported.(SCGCQ01514527) - SCGCQ01515443: WG: Typo in Event ID: 114 of PD state Change event related to sheild state.(SCGCQ01515443) - 502 bad gate way observed on enclosure cable push/pull.(SCGCQ01524150) - WG : LSA allows to add VD on offline DriveGroup and operation fails anyways.(SCGCQ01526342) - MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01532725) - LSA shows wrong diskgroup info when you have foreign PD.(SCGCQ01590450) - Lenovo_18B: Not able to set max no of PD using set patrol read properties in LSA/Storcli.(SCGCQ01681070) - Fixed: LSA handle count increase was observed.(SCGCQ01713154) - Lenovo CIT 18B: LSA Linux doesn't have latest storelib.(SCGCQ01713580) - SCGCQ01385340: Health is not coming proper after foreign config import..(SCGCQ01385340) - Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389892) - MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01419325) - WG: Not all space in "Foreign Configuration" tab is clickable..(SCGCQ01467702) - WG: Font style across the "Advanced Configuration" form should be made same..(SCGCQ01472063) - Removing dead code from LSA7.5 stream..(SCGCQ01472185) - WG: "Ok" button needs to be in caps in "Mixed listed drives" confirmation page and one more cosmetic change..(SCGCQ01472190) - WG: There is no alignment for the error message while user changes the personality mode when PR is in progress..(SCGCQ01474932) - WG: LSA is not allowing User to change No of PD's allowed for Patrol Read in Set PR properties through KeyBoard..(SCGCQ01479402) - WG: Trying to clear configuration does not show any warning in server summary page regarding cached data, in CC page it shows.(SCGCQ01486698) - WG: Select all check box is still selected even if one of the drive group is unselected while assigning HSP to existing DG.(SCGCQ01488141) - WG: while creating FDE VD, type by default is selected as "All" in PD selection pane, unable to select all FDE drives.(SCGCQ01488169) - Requested personality field is not updated for Ventura.(SCGCQ01494598) - temperature change in controller is not refeclected in LSA..(SCGCQ01500344) - Set patrol read window shows a time in past..(SCGCQ01503810) -.(SCGCQ01508528) - SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01509259) - WG: LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01509708) - LSA Server: Set Patrol read is not shown when the volume is created with SSD.(SCGCQ01511260) - SCGCQ01513209: WG: Simple configuration tab show invalid options before the raid level drop down list the supported raid levels.(SCGCQ01513209) - WG : Advanced configuration tab gets disabled after secure erasing the FDE foreign drives.(SCGCQ01514728) - SCGCQ01521013: MR 7.5_LSA: LSA gives wrong message after Online FW Update on Ventura IMR controller.(SCGCQ01521013) - MR 7.5_LSA: LSA keeps on refreshing during the background operations- Full init, RLM, CC etc.(SCGCQ01522807) - WG: Behavior mode is missing in "personality management" window..(SCGCQ01523045) - SCGCQ01525738: MR 7.5_LSA: Wrong nginx version is reported in linux ( SLES and RHEL ) Operating Systems..(SCGCQ01525738) - Instance validation issues with LSA build 4.55 with IR3 controller.(SCGCQ01528425) -.(SCGCQ01628332) - WG: Current Profile is not selected by default in the table that lists the available profiles for the controller..(SCGCQ01442481) - WG: "%" is accepted along with the input for Expand VD value - But not accepted for all..(SCGCQ01445384) - WG: Partition line is required in Controller Properties Page..(SCGCQ01445396) - WG: Status icon of physical drive is not changed after changing the state of the PD from rebuild to offline..(SCGCQ01461144) - WG:LSA doesn't allow to secure more than one DG using FDE..(SCGCQ01472853) - SCGCQ01474327: Handle dynamic length serial number as part of serial number VPD page 0x80.(SCGCQ01474327) - WG: GUI : Cosmetic issues in clear configuration notificationp.(SCGCQ01486692) - WG: LSA does not notify the user with notification on starting the VD initialization.(SCGCQ01487270) - WG: able to add VD for scheduling consistency check even after all the VD's have been deselected.(SCGCQ01489509) - WG:Add physical Drive button is clickable before VD list is loaded while scheduling CC or PR, no notification to user to wait.(SCGCQ01489885) - LSA provides option of performing an RLM operation on Degraded VD, which fails.(SCGCQ01489942) - LSA: Virtual drive, spare and drivegroup is not supported for IT but seen in URI response for Physical drives..(SCGCQ01500099) - WG: Selection of different drive type is activated after few clicks.(SCGCQ01503786) - RWC3 launch tab is showing the LSI Storage Authority.(SCGCQ01503896) - WG : Pop up for securing FDE drive has inconsistency in text.(SCGCQ01507972) - In settings window "Restore Default Alert settings" button is not saving the default values.(SCGCQ01508002) - WG: Confirm Check box is not aligned with the "Enable Security" button.(SCGCQ01511250) - LSA WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01511390) - WG:Server Logs does not contain status of energy pack it mentions "Requested element not found in the stack.":error "69634".(SCGCQ01512318) - WG: Spell Check issues with "message_en.js" used for displaying the GUI notification.(SCGCQ01512377) - Sorting of Event logs wrt View Events and Download Logs.(SCGCQ01512750) - WG: LSA add physical Disks pane shows empty drive list even if there are 182 drives for adding for RLM operation.(SCGCQ01513656) - Controller operations schema instant validation is failed.(SCGCQ01514528) - WG: LSA shows the message "The virtual disk has not been initialized" even when 32 VD's have been selecte.(SCGCQ01521694) - Lenovo-18B: IPV6 IP is overlapping OS name and arch in LSA GUI if we see server discovery page in list view in SLES12 SP3.(SCGCQ01595641) - WG: "Virtual Drive expanded successfully" message is still shown even after the page refresh post VD expansion..(SCGCQ01445693) - WG: Cosmetic changes required in tooltip messages of Configure options in Controller Actions..(SCGCQ01447797) - WG: Space is required between RAID and it's type in Available UG drives form and one more cosmetic change..(SCGCQ01472194) - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733) - LSA: partial VD hide operation is failing..(SCGCQ01484118) - SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01506090) - WG:Launching LSA using ip:2463 in browser, User can see the HOME page flash before redirecting to Remote discovery.(SCGCQ01439795) - WG: LSA displays empty box instead of "Action Successful" for "Prepare for removal" and "Undo prepare for removal".(SCGCQ01447823) - WG: "Adding the virtual drive will add the corresponding virtual drives for PR" is not shown when "select all" box is used..(SCGCQ01461133) - WG: Size of "Back" & "Save" buttons are not same once the user saves the changes after scheduling CC.(SCGCQ01472749) - WG: Hand symbol is not seen for close button while Adding drive during reconstruction of a DG.(SCGCQ01473748) - Disabling the add PD button.(SCGCQ01488036) - WG: no notification shown on assigning dedicated hotspare to existing DG.(SCGCQ01488155) - System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989) - WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01509681) - WG: Error message on a failed operation of RLM in displayed outside the allocated space.(SCGCQ01515263) - WG: arrow mark in the link " <- Go back to Drive Group, Drives and Other Hardware list" is not clickable.(SCGCQ01442471) - WG: Expand windows is showing the capacity in decimal value with too many integers after decimal point..(SCGCQ01445686) - Address Code review defects for ER SCGCQ01416373.(SCGCQ01455923) - WG: Ambiguous "Success" message needs to be changed for disabling drive security.(SCGCQ01461177) - Cannot import foreign configuration from LSA.(SCGCQ01524354) - WG: Email setting tab heading of LSA displays the entire sentence with "_" in between instead of space.(SCGCQ01563343) - SCGCQ01599526: Lenovo PE: Memory Leak in LSABug.(SCGCQ01599526) EnhancementRequests (20) - New configuration params added for EPD-PT devices.(SCGCQ01599607) - API changes needed to support eHBA product series.(SCGCQ01727346) - Create sanitize events.(SCGCQ01713708) - Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177) -.(SCGCQ01404233) - SCSI UNMAP switching support from LSA GUI.(SCGCQ01461207) - NVDATA parameter to OPAL SED.(SCGCQ01614689) - Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135) - Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234) - API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667) - LSA: Make heavy operation by wrapping scheduler call.(SCGCQ01416373) - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443721) - LSA Server: PR:SCGCQ01231749 -- Show controller temperature in LSA for RAID and SAS IT controllers.(SCGCQ01443731) - Support drive Select ALL functionality in LSA GUI PD Operations and Mixing of drives during vd creation.(SCGCQ01454110) - SCGCQ01454353: Retrieve and process the ESXi events in a single shot.(SCGCQ01454353) -.(SCGCQ01454367) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340) - We will be removing the confirmation popup from all the actions as we got here from multiple forms like this pop up is annoying.(SCGCQ01447015) - Support drive Select ALL functionality in LSA GUI VD/DG Operations.(SCGCQ01453114) -.(SCGCQ01472631) CSETActivities (87) - In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411631 port of SCGCQ01397546) - MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01420224 port of SCGCQ01419325) - LSA service is not working in Linux.(SCGCQ01443712 port of SCGCQ01442733) - WG: Event Log table headers needs space - Cosmetic..(SCGCQ01464556 port of SCGCQ01460053) - SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01466763 port of SCGCQ01424621) - MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320) - Updated PD firmware version is not reflecting even after LSA refresh..(SCGCQ01501204 port of SCGCQ01382013) - Cisco_Plumus_LR :Proper spacing should be there in between Event and History in view event logs "EventHistory not generated"..(SCGCQ01502201 port of SCGCQ01385344) - While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure.(SCGCQ01503907 port of SCGCQ01315392) because of which the issue.(SCGCQ01503926 port of SCGCQ01288032) - fixed: clear drive should not be candidate drive for create configuration.(SCGCQ01503958 port of SCGCQ01196088) - Fixed: Span order is in reverse compare to other apps.(SCGCQ01504234 port of SCGCQ01330269) - LSA shows max pd for Raid 1 without checking support of Raid 1E.(SCGCQ01514472 port of SCGCQ01513338) - Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531154 port of SCGCQ01521114) - Making rebuild drive offline lsa gets 404..(SCGCQ01564627 port of SCGCQ01542412) - LSA Crashes after clicking on foreign configuration.(SCGCQ01564739 port of SCGCQ01545262) - Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565025 port of SCGCQ01504080) - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01565116 port of SCGCQ01555955) - Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368) - SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621 ) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01599402 port of SCGCQ01563340) - MR7.6_LSA: No Foriegn configuration details is shown in LSA.(SCGCQ01605344 port of SCGCQ01581943) - fixed: logout causing unexpected behavior during end cim connection for vmware systems.(SCGCQ01609343 port of SCGCQ01578248) - SCGCQ01355833: WG:After deleting the cookies from browser, DA does not go back to login page..(SCGCQ01614982 port of SCGCQ01355833) - LSA displays "Erase operation is successful" when replace operation is in progress on the drive in same drive group..(SCGCQ01617930 port of SCGCQ01401460) - SCGCQ01506090: WG: In Settings under email tab , email id list will always have an empty row once we add and remove email_id.(SCGCQ01620406 port of SCGCQ01506090) - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01634072 port of SCGCQ01473733) - Raid 1 Volume creation using 4 drives is displayed as Raid 1E.(SCGCQ01686231 port of SCGCQ01686106) - Cannot use Special Characters in Domain Name for LSA Login.(SCGCQ01747012 port of SCGCQ01745768) - LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected..(SCGCQ01448948 port of SCGCQ01442107) - DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01460039 port of SCGCQ01451571) - WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts..(SCGCQ01465657 port of SCGCQ00903348) - DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01466743 port of SCGCQ01451571) - LSA server giving null for enclosure serial number.(SCGCQ01466744 port of ) - Address Code review defects for ER SCGCQ01416373.( port of SCGCQ01445713) - MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01484107 port of SCGCQ01482320) - Added fwflash status as part of controller health status.(SCGCQ01503830 port of SCGCQ01375153) - While retrieving the enclosure details instead of referring to the ENCL structure, in this case LSA is referring the PD structure because of which the issue.(SCGCQ01503955 port of SCGCQ01288032) - [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01514258 port of SCGCQ01506045) - System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01514469 port of SCGCQ01507989) - Allows raid 1e input even if RAID 1E is not supported by fw.(SCGCQ01514756 port of SCGCQ01513331) - Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834) -.(SCGCQ01520055 port of SCGCQ01508528) - Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01564633 port of SCGCQ01562368) - Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674) - WG: LSA service crashes on trying to login with URI having incorrect mac address of the server.(SCGCQ01615042 port of SCGCQ01601386) - MR7.6: LSA crashed with a mouse click on VD.(SCGCQ01685343 port of SCGCQ01641760) -.(SCGCQ01685548 port of SCGCQ01685009) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687173 port of SCGCQ01686105) - LSA is not showing the proper message when user unlocks the foreign jbod drivesin JBOD mode.(SCGCQ01716641 port of SCGCQ01716622) - SDS/HBA progress issues.(SCGCQ01460070 port of SCGCQ01052983) - Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01460084 port of SCGCQ01435908) - SCSI UNMAP switching support from LSA GUI.(SCGCQ01461211 port of SCGCQ01461207) - C480-M5: LSA downloaded event log needs better decoding.(SCGCQ01501225 port of SCGCQ01321211) - Cisco - CSCve68492 - Storage Logs display a blank event when a secure PD is unlocked.(SCGCQ01503902 port of SCGCQ01359128) - SCGCQ01509259: WG: Separator is missing in few places of event logs..(SCGCQ01514773 port of SCGCQ01509259) - WG: Infinite request observed on stopping LSA and Nginx services..(SCGCQ01526363 port of SCGCQ01509681) - SCGCQ01547992: WG: standalone LSA Installation on Rhel 6.9 32 bit notifies user with invalid message.(SCGCQ01564682 port of SCGCQ01547992) - LSA: Warning Message needs to be changed when there is Controller firmware update failure.(SCGCQ01604992 port of SCGCQ01564526) - SCGCQ01599526: Lenovo PE: Memory Leak in LSA.(SCGCQ01633836 port of SCGCQ01599526) - Secure Jbod unlock is not showing the proper error message in LSA.(SCGCQ01680728 port of SCGCQ01677101) - LSA detects secured JBODs as unconfigure good when drives moved to another system -StorCLI detects them as foreign config.(SCGCQ01687172 port of SCGCQ01686080) - Cisco - CSCvi84075 - LSA, CTRL-R and HII doesn't display the foreign config when MAX VDs are present.(SCGCQ01718980 port of SCGCQ01698211) - LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460090 port of SCGCQ01460076) - WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan..(SCGCQ01460400 port of SCGCQ01448976) - Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01481410 port of SCGCQ01474461) - LSA build script automation for VBAS environment.(SCGCQ01497385 port of SCGCQ01385344) - Activity to check-in version files in common.(SCGCQ01520315 port of SCGCQ01512599) - Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114) - MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622) - LSA Client 7.6: SPAN drives order is not maintained.(SCGCQ01614833 port of SCGCQ01539355) - Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline..(SCGCQ01443689 port of SCGCQ01442554) - LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048) - SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux..(SCGCQ01480902 port of SCGCQ01479375) - LSA WG Fury IT: Fury Device ID is showing as 00 instead of 0x0097 in controller properties logs..(SCGCQ01564943 port of SCGCQ01534444) - Modify the LSA Health Algorithm to consider the Blocked VD.(SCGCQ01565119 port of SCGCQ01504080) - Cisco - CSCvi55512 - CC in concurrent mode runs only on 2 VDs at a time.(SCGCQ01676612 port of SCGCQ01670094) - LSA Wont display foreign data when enclosure information in not populated properly.(SCGCQ01686054 port of SCGCQ01685449) - LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392) -.(SCGCQ01564591 port of SCGCQ01515389) - API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01460393 port of SCGCQ01436886) - LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401) - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340) - LSA WG Inturder IT: 0 Byte drive is missing after sorting the drives based on capacity of drive..(SCGCQ01564629 port of SCGCQ01550970) - LSA WG Fury IT: Controller type is showing as IR for IT card.(SCGCQ01564631 port of SCGCQ01540821) - I/Os are not recover after drives pull for DHSP to rebuild..(SCGCQ01564737 port of SCGCQ01514206) 4.011.000.000 - Moderate Impact ------------- Defects (234) - SDS/HBA progress issues.(SCGCQ01052983) - Fixed: Added relevant null pointer checks.(SCGCQ01319978) - Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01321474) - Start PatrolRead success dialog box needs change in alignment.(SCGCQ01324866) - WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01325783) - Link speed is not displaying any details in LSA.(SCGCQ01326129) - Defect to check in code review defects.(SCGCQ01329391) - Client js file changes for 7.3.(SCGCQ01331593) - On Successful Firmware flash client displays improper Icon Message.(SCGCQ01332708) - Control panel of LSA Help & support link still has reference to LSI. should be changed to broacom.(SCGCQ01337321) - LSA asks for user permission to navigate away on clicking home button after creating simple configuration.(SCGCQ01338009) - WG: GUI Issues pertaining to FW flash ER implementation SCGCQ01273627: Request to improve message displayed during FW Update.(SCGCQ01342542) - IR Card global hot spare assignment is not refreshing the page.(SCGCQ01345357) - Cisco_HSW_Validation_LSA: LSA accepting decimal values for "Set Adjustable Task Rate" which is saved as round value.(SCGCQ01345553) - LSA 7.3 Client Coverity fix.(SCGCQ01347309) - Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01350435) - WG:descripancies in update firmware page after selecting load bios option.(SCGCQ01350865) - SCGCQ01350908: WG:Temperature of Unconfigured Drive is displayed as 0C under More properties.(SCGCQ01350908) - WG:LSA displays Redhat icon in remote discovery page ,though SUSE is installed in system.(SCGCQ01351455) - LSA taking the max VD size value when the user presses ENTER after specifying the VD size.(SCGCQ01356216) - SCGCQ01356217: WG: LSA Service crashes on trying the PD details of the simple config created.(SCGCQ01356217) - LSA_MR_7.3_Alpha: Save option can be grayed out or disabled after user saves the changes for schedule CC.(SCGCQ01357152) - LSA_MR_7.3_Alpha: LSA doesn't display consistent Foreign Configuration information to the user.(SCGCQ01358048) - WG: Incorrect notification shown after selecting 32 virtual drives.(SCGCQ01358095) - SCGCQ01358097: LSA_MR_7.3_Alpha: Space optimization between the size value & size unit is needed in foreign configuration page.(SCGCQ01358097) - LSA_MR_7.3_Alpha: User cannot select "Advanced Configuration" by clicking on the description below it in Server landing page.(SCGCQ01358122) - LSA_MR_7.3_Alpha: Space Alignment for better presentation needed in Server Profile Page.(SCGCQ01358148) - LSA_MR_7.3_Alpha: Percentage value for the Background Operations is not seen if browser is zoomed.(SCGCQ01358261) - LSA crash when service starts with empty LSA.conf file.(SCGCQ01358264) - SCGCQ01358892: Buttons "Try Updating Again" is not highlighted when user attempts to flash the firmware after any failure.(SCGCQ01358892) - SCGCQ01358947: WG: Invalid text Content displayed on selecting multiple Virtual drives/Physical Drives.(SCGCQ01358947) - WG: "Select Personality" dropdown lists the current personality first by default.(SCGCQ01359030) - WG: Clickable "hand icon' is not displayed when we move cursor over Bus dev text of controller in Server summary page.(SCGCQ01359034) - SCGCQ01372670: When User tries to click on Update FW Button, LSA asks for Navigation Confirmation without displaying Update FW page for IT.(SCGCQ01372670) - "Add CacheCade-SSD VD" tab getting greyed out after deleting created vd,even if physical drive is selected under "Add SSD pd".(SCGCQ01372722) - WG: VD creation fails when multiple VD's are created with 1MB size.(SCGCQ01373500) - "Finish" button in Modify drive group work even if its grayed out.(SCGCQ01374945) - WG: Issues pertaining to Controller Diagnostic logs.(SCGCQ01375839) - WG: GUI Issues pertaining to Instant secure erase of an FDE Drive.(SCGCQ01375858) - There is a mismatch about Backplane (Enclosure) "Product ID" and "Enclosure Model" in LSA.(SCGCQ01376005) - Spare URI does not respond on iMR Invader.(SCGCQ01376605) - WG: After physically removing the PD from the R10 DG, the DG Span tab does not load.(SCGCQ01376781) - "Since Log Clear" does not create the last event "Log Clear" in Var/log/messages.(SCGCQ01376849) - WG: LSA does not list the Drive Group Tab , on creation of 240 VD (15 DG, 16 VD in each of DG) and reinstalling the LSA.(SCGCQ01378585) - WG: Windows Application Event viewer lists 31 events instead of 30, after installing LSA with the option "Since Last reboot".(SCGCQ01378669) - WG: LSA does not automatically refresh on hiding an Degraded DG.(SCGCQ01378693) - Client: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01378778) - Client: WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01378782) - WG: unable to start VD initialization on 32 VD's when there are 240 VD created & Foreign configuration present in system.(SCGCQ01378808) -.(SCGCQ01378812) - WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01379795) - WG:In premium features Safe ID & Serial Number needs to be highlited for better understanding.(SCGCQ01379818) - WG: Close button can be given with a "hand" symbol in Compare and select form like all close button in other form has.(SCGCQ01380587) - WG: Available Unconfigured drives is not formatted properly for display.(SCGCQ01380591) - WG: Domain Authentication is shown as Default in "MAnage Server Page".(SCGCQ01380642) - Size increment button is not working while modifying a VD that is created in MB size.(SCGCQ01380830) - WG: "Advanced and Simple Configuration" is enabled when UG drives are "prepared for removal" and no other drives are left.(SCGCQ01380977) - SCGCQ01383828: LSA service crashes while trying to access the IR3 controller.(SCGCQ01383828) - WG:VD properties were not well partitioned for CacheCade - SSD config , compare to normal VD creation in HDD.(SCGCQ01384561) - WG: Few enhancements needed in VD Expand form.(SCGCQ01389165) - SCGCQ01389195: WG: Naming convention for VD can be made consistent for the VD's created through Advanced and Simple configuration.(SCGCQ01389195) - Enter key is functioning as a backspace in "Set Adjustable Task Rate" - Can be disabled.(SCGCQ01389203) - LSA mail server settings does not allow to enter name of smtp server.(SCGCQ01389204) - WG: No. of VD's available to create is not shown properly for spanned vd's when span depth is modified.(SCGCQ01389421) - Storcli: Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01392000) - WG: More Actions for drive is not working after staring and stopping Clear operation under Drives tab.(SCGCQ01392056) - WG: User has to click twice on the table header to change the sorting order for any table in LSA.(SCGCQ01393336) - Copyright link is taking to top of the page rather taking to Broadcom website.(SCGCQ01393706) - WG: PD state info is not updated properly in the Drives tab after PD's are converted from online to offline.(SCGCQ01393771) - WG: "Clear" and "Rescan" buttons could be highlighted for the better look in Foreign Configuration Tab.(SCGCQ01394954) - "Add Virtual Drives" is grayed out for specific VD sizes after user presses "tab-alt" keys.(SCGCQ01398966) - WG: Verify and Sign In Buttons are overlapping in list view in Manage Server Page.(SCGCQ01399610) - LSA is not showing "Activate..." button for Premium Features when it is navigated after "Update Firmware" page.(SCGCQ01399670) - WG:LSA sending email alert notifications to user which doesn't exist.(SCGCQ01418580) - Drives under both Physical drives and Span drives tab are allowed to select simultaneously.(SCGCQ01428129) - Login to VMware is taking at time more than 30 seconds.(SCGCQ01429431) - Physical drives Get call taking considerably long time :it takes 5+ minutes to respond for 24 PD's in an enclosure.(SCGCQ01435908) - WG:while editing a created VD, user cannot increase the VD size in MB .Only can decrease the size.(SCGCQ01438268) - WG:LSA is not sorting properly the drives with different capacity of units i.e TB and GB.(SCGCQ01439751) - WG: View server profile does not contain info on the Device id, which is sorted according to device id itself.(SCGCQ01440773) - WG: operation of Combining JBOD drives with & without files system to move to Unconfigurued good is partially successful.(SCGCQ01440778) - WG: Space required between two strings in the description of "Enable Drive Security".(SCGCQ01442479) - WG: LSA Displays "Error Code:1:An user is already Logged in with Different Credentials" even user is using same credentials.(SCGCQ01442773) - WG: LSA is changing to latest login user account though it is already logged with different User Account in different Tab.(SCGCQ01442774) - WG: No. of UG drives are improperly updated in the Drives header tab when replace operation is triggered on a physical drive.(SCGCQ01444724) - WG: No. Of Power Supplies info displayed is overlapping on the enclosure details. Need proper display alignment.(SCGCQ01444794) - LSA showing 'binaryPath:./LSA' during service start in Linux.(SCGCQ01445709) - LSA server giving null for enclosure serial number.(SCGCQ01445713) - WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01445719) - WG: Description for event Code"579" is '0" in LSA event logs.(SCGCQ01446803) - WG:"Disable Data Protection" is not updating in LSA until user do a manual refresh.(SCGCQ01447843) - SCGCQ01448707: WG: LSA Event logs has enquiry info for Vendor, model and serial numbers appended with $ symbols.(SCGCQ01448707) - WG: Inconsistency seen w.r.t making drive online while RLM is in progress.(SCGCQ01449722) - WG: Event log page is navigating to change personality when the behavior mode is set from other tab of the same browser.(SCGCQ01450719) - DG count is shown incorrectly in server summary page : VMware 6.5.(SCGCQ01451571) - WG:Controller health status not updated on moving JBOD drive from offline --> online, personality : JBOD.() - LSA Server: Handling of additional events in Cache module.(SCGCQ01451573) - LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01464514) - [lenovo 18A] [Bugzila 117507] -Reopen -The LSA doesn’t work in Suse12.3, which has many NICs.(SCGCQ01506045) - WG: Enclosure ID is shown "Unknown" for NVMe JBOD only in event logs, Profile id=11.(SCGCQ01291162) - WG: LSA page does not refresh on starting Full initialization on 240 VD.(SCGCQ01292183) - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964) - 7.3 Client : Coverity defects check-in.(SCGCQ01308624) - SCGCQ01309034: Coverity defect fixes check-in.(SCGCQ01309034) - Fixed: Code maintainability issue.(SCGCQ01318344) - coverity defect fies for : Suspicious use of non-short-circuit boolean operaton.(SCGCQ01320079) - In Simple Config, if user select a VD and select the check box of "Assign HSP", VD size is getting changed to different size.(SCGCQ01321225) - WG: LSA notifies user that VD will be deleted after VD erase even if the option was not selected.(SCGCQ01325795) - WG: user notification appearing after user starts/stops the initialization on multiple VD's needs to be updated.(SCGCQ01326134) - LSA doesn't show FW component name while FW flash operation.(SCGCQ01337028) - WG: Multiple options of RLM are selected together for radio button used to select one of the 3 RLM operations.(SCGCQ01342615) - LSA does not display "Link Speed" for phy 8 properly for iMR Ventura.(SCGCQ01355929) - When the CC is scheduled as "Continuously", it is not reflected in UI after saving the changes.(SCGCQ01357007) - Warning message has to be corrected in Foreign configuration page and one more hyperlink issue.(SCGCQ01358066) - LSA is not taking "dot(.)" from num pad , but taking "dot(.)" form keypad while specifying the vd capacity.(SCGCQ01358908) - Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01364736) - WG: LSA displays the notification "This operation can be performed only on 32 drives at a time" 32 times.(SCGCQ01373067) - WG: Global hotspare & Dedicated hotspare are displayed as plural entities for every hotspare listed in physical drive tab.(SCGCQ01375707) - WG: Instance Validation failed for Spares GET URI : MR Ventura.(SCGCQ01375778) - fixed: Min & Max of "PdRaidLevel_1E" under the "pdsForRaidLevels" is populated even though it is not supported in iMR.(SCGCQ01375817) - WG: Other hardware tab lists wrong count of list of hardware connected when enclosure connected in multipath.(SCGCQ01376109) - WG: View server profile contents exceed the border limits of the LSA page.(SCGCQ01378556) - SCGCQ01378774: WG: Information of the virtual drive info and PD's involved in DG vanishes on removing & inserting the PD back from a DG.(SCGCQ01378774) - WG: Links present in Backplane properties are so light that they look like grayed out. Needs enhancement.(SCGCQ01380680) - WG: User is allowed to click on "Next" button even if page is not completely updated during the VD creation & RLM operations.(SCGCQ01381734) - GUI Issues found in Advanced Configuration page.(SCGCQ01381764) - Firmware flash message should have "new" removed from string.(SCGCQ01382062) - LSA getting logged in , even if the password is wrong.(SCGCQ01388957) - "%" is allowed for entering no. of seconds for locating the drives.(SCGCQ01389182) - WG: Size limit warning is thrown if the user is giving valid size using spinner button while modifying VD.(SCGCQ01389340) - WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01389483) - Spinner Button for increase and decrease size is not working when the size is 1.09 TB.(SCGCQ01392053) - WG: "Username" has to be grayed out when user start typing in the login page of "Manage Server Page".(SCGCQ01393764) - WG: UG Drives count is not updated properly after modifying a DG.(SCGCQ01393774) - Phase 5 IT LSA - EFI-BSD version is not displayed fully when Version length is more than 12 characters.(SCGCQ01394914) - Mismatch in enclosure properties between LSA and storecli utility.(SCGCQ01395021) - WG: "Managing SAS Storage Link Speed" opens up on clicking help topic of "Manage PCIe Storage Interface".(SCGCQ01395075) - when clicking on more actions for any UG drives to make DHS,the options remains as it is in LSA though the operation is done.(SCGCQ01403884) - WG: Like "Flash Firmware" button in "Update Firmware" page, "Update" button should also have hand symbol & one more issue.(SCGCQ01405822) - WG: while expanding exiting VD, the expand VD page is not consistent.(SCGCQ01416379) - Fixed: WG: LSA conf does not contain the perf mode settings options configurable.(SCGCQ01422214) - WG: Clicking on "Benefits of each MegaRAID Advanced Software Option" in premium feature is not taking to proper link.(SCGCQ01428156) -.(SCGCQ01428383) - LSA doesn't allow creating spanned Raid levels with 2 spans using more than 32 drives.(SCGCQ01435647) - API performance Issues pertaining to LSA Build 004.002.000.000( VMware esxi 6.5 ).(SCGCQ01436886) - WG : "Replace Drive "window needs improvement to look uniform.(SCGCQ01439805) - when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01440772) - WG: LSA displays the property Drive Security Capable as 'No' even when security is supported.(SCGCQ01442209) - WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01443879) - WG: Confirmation Message has to be changed when more than one drives are converted from JBOD to UG state.(SCGCQ01444672) - SCGCQ01445818: MR 7.4_Alpha_LSA does not find a server in RHEL 7.4.(SCGCQ01445818) - WG: LSA times out after "Clear Configuration" command is issued when there is a OFFLINE DG present.(SCGCQ01447788) - WG: Size for the VD is not updated properly when edited during VD creation.(SCGCQ01447791) - WG: An extra "." needs to be removed in the event description for "Initialization complete on VD".(SCGCQ01449783) - WG:Instance Validation Fails for foreignConfiguration-schema.json in iMR_Ventura.(SCGCQ01473733) - WG: Raid 50 Vd Creation fails on unselecting drives after changing span during VD creation.(SCGCQ01309542) - Coverity Defects - Performance Inefficiencies.(SCGCQ01313878) - Fixed: Coverity: Class hierarchy inconsistencies.(SCGCQ01318333) - Client: Coverty defect fixes check-in.(SCGCQ01318336) - VD size getting increased while creating VD using simple config - Regression.(SCGCQ01341947) - WG: Once the FW update is completed LSA shows junk character in the notification about firmware flash was successful.(SCGCQ01342536) - SCGCQ01348082: LSA: Loopback occurs during launch. (intermittent issue).(SCGCQ01348082) - Expand page is not closed when opened for second time.(SCGCQ01357224) - "Add Virtual Drives" is disabled when user changes from invalid size to valid size through increment button.(SCGCQ01358299) - WG: Error message that user encounters for Max User login, message needs to be displayed with proper message.(SCGCQ01375255) - "Server Profile" displays blank back plane info for ctrl-1.(SCGCQ01375992) - LSA Client : Foreign Configuration Panel issues with locked and unlocked foreign drives.(SCGCQ01378050) - DG Actions menu is not shown properly after zooming in when VD's are hidden.(SCGCQ01380663) - WG: Size range warning is not shown while modifying VD when unit is selected from MB to GB.(SCGCQ01380818) - LSA Evevnt: Access policy for HIDDEN/Transport is coming as Empty.(SCGCQ01380828) - LSA Server: User is provided with Hide and Un-Hide option though there is no HIDE performed on a VD.(SCGCQ01380845) - WG: LSA service crashes on hiding and unhiding DG's with dedicated hotspare.(SCGCQ01380912) - SCGCQ01383765: Resolve linux server compilation issues.(SCGCQ01383765) - WG: Reconstruction progress is not refreshed even after the VD is cleared on which reconstruction was happening.(SCGCQ01383800) - LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01389392) - WG: Clicking on View server profile just before controller console page loads results in blank page.(SCGCQ01396731) - WG: "DG degraded notification" is not auto-refreshed after Raid5 VD is brought from offline to online.(SCGCQ01398964) - WG: When LSA is configured with NAT server, it is shown twice in the Remote Discovery Page.(SCGCQ01401484) - WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01401546) - WG: Hidden links present in premium features page.(SCGCQ01412883) - WG:VD properties details need some changes to look uniform across the application.(SCGCQ01418574) - WG: Help link for Premium Features is opening in dual tabs.(SCGCQ01428169) - LSA: patrol reads gets initiated on all the vd's that are created though only one vd is selected.(SCGCQ01442107) - WG:LSA is not showing the options "Pause Patrol Read|Abort Patrol Read" when PR background operation is running.(SCGCQ01442350) - WG:when user is closing the message box for "Clear Configuration",the "X" symbol is not shown with hand symbol.(SCGCQ01442356) - LSA service is not working in Linux.(SCGCQ01442733) - WG: Invalid text"Each_Frehole" present in Pop up of Adding VD to existing Drive group.(SCGCQ01446454) - WG: "Add Hot Spare" Button is enabled after selecting and deselecting the drives.(SCGCQ01448882) - WG: LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01448976) - WG: Event with ID 552 is not updated properly. Information on Mode is empty.(SCGCQ01450725) - LSA Client: SDS/HBA progress issue.(SCGCQ01459948) - System x PE: LSA Does Not Support the Hyphen Character "-" In Domain Names.(SCGCQ01507989) - LSA not giving the Un Hide All Virtual Drives operation when DG contain Hidden and normal VDs.(SCGCQ01308440) - Coverity Defects fixes for Stream LSA7.3.(SCGCQ01311864) - LSA7.3: Coverity defect fixes in Server code.(SCGCQ01316168) - Coverity: Integer handling issues.(SCGCQ01318418) - LSA Client : IR/IT Multiple Options are allowed in Update Firmware Screen.(SCGCQ01343645) - Add hot spare page cosmetic issues.(SCGCQ01358219) - WG:Change button is active even if button appears inactive for "Change personality", fails with an inappropriate notification.(SCGCQ01358967) - FW last modified time is not coming properly while FW upload.(SCGCQ01359056) - WG:while editing created vd for CacheCade - SSD Caching Configuration,the write policy tab is coming down.(SCGCQ01380641) - WG: In "Advanced Configuration" page, Raid settings and Drive Attributes are not numbered properly.(SCGCQ01380646) - WG: Issues pertaining to "Server is taking long to respond" LSA page.(SCGCQ01383122) - SCGCQ01395189: WG: "Manage PCIe Storage Interface" displays empty table for MR Ventura controller with profile id 13.(SCGCQ01395189) - WG: LSA is displaying loop-back address in remote discovery page while accessing LSA with IPV6 address.(SCGCQ01415223) - WG: Question mark missing in "Erase" confirmation form.(SCGCQ01415923) - WG: Extra "." (dot) has to be removed in VD Initialization confirmation message and one more cosmetic issue.(SCGCQ01428137) - WG: Instance Validation is failing for driveGroupConfigurationService-schema.json in MR_Ventura card.(SCGCQ01443739) - MR7.4_Alpha_LSA crashed when trying to download firmware RHEL 7.4.(SCGCQ01447240) - LSA Client Refresh issue while making more than one drive(s) offline when RLM is in progress.(SCGCQ01449870) - WG: No success /failure Notification is shown in server summary page on making a offline drive online.(SCGCQ01451575) - WG:2 Spans(Modify Span Depth) is showing in "Advance configuraton" page even if their is no PD left for the config.(SCGCQ01452129) - WG:when flashing FW with 16 mb/32 mb.ROM file , LSA throws inappropriate message.(SCGCQ01464425) - SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01479375) - WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ00903348) - LSA should not allow to select the check box of VD and PD simultaneously on xSDS-None mode.(SCGCQ01323724) - Issue : Instant Secure erase option is seen when FDE and NON-FDE drives are selected.(SCGCQ01326164) - SCGCQ01332799: Resolve LSA server compilation issue.(SCGCQ01332799) - LSA conf file not being updated While changing the default port 2463 and 9000 to some other free ports in windows_8.1_x64.(SCGCQ01375895) - WG: "?" symbol is in the centre of the Drive erase page unlike in other pages.(SCGCQ01383763) - WG: ESXi server name is not completely visible in Manage Servers page.(SCGCQ01389332) - WG: UI Enhancement: Hand symbol has to be given for the "Modify VD" icon for better user experience.(SCGCQ01389343) - Foreign Configuration issues locked and unlocked foreign drives count.(SCGCQ01391010) - Action successful message needs to be modified for better User experience.(SCGCQ01392057) - spandepth need one space between span & depth, to look uniform across the application.(SCGCQ01413225) - Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01423352) - LSA is not Displaying Both the Foreign Configurations (Encrypted and Unencrypted) for Import/Clear/re scan.(SCGCQ01460076) - WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01394281) - WG: Help link for "Activate Features" after providing the Activation key is not working.(SCGCQ01398969) - SCGCQ01424621: PD serial number getting truncated on few PDs.(SCGCQ01424621) - Added the "?" at the end of instant secure erase. But there no issue related line in more actions panel please find the attached screenshot.(SCGCQ01442352) - Fixed: LSA app UI cannot be opened when connect M.2 NVME SSD(via HSBP) to LSI 9460-16i/9440-8i.(SCGCQ01474461) - 'X' symbol for removing physical drives are not highlighted when the drives are allowed to be removed.(SCGCQ01350436) - API performance Issues pertaining to LSA Build 004.005.000.000( VMware esxi 6.5 ): Raid Mode with JBOD drives.(SCGCQ01467754) EnhancementRequests: - Add "Incompatible with Profile" event.(SCGCQ01289924) - SLIR3: Change build scripts and makefiles to account for change in directory structure and new name of the library.(SCGCQ00293713) -.(SCGCQ01389581) - LSA Page tab name should be changed.(SCGCQ01401514) -.(SCGCQ01416369) - Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444590) - Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048) - Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149) - SLIR3: Remove Libsysfs dependency in StoreLibIR3.(SCGCQ00293709) - Adding Solaris and Sparc X64 bit support in SLIR3.(SCGCQ00922699) - Change library name to SLIT.(SCGCQ00933175) -.(SCGCQ01309820) - LSA Server : [Lenovo Purley] Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01352474) - HBA nvdata version in Decimal Format in LSA.(SCGCQ01365643) - WG: Dedicated Hot spare Notification pop-up alignments.(SCGCQ01401505) - Schedule API changes for time consuming APIs.(SCGCQ01422386) - MR7.4: Support for FW ER:SCGCQ01389581 in LSA Server.(SCGCQ01428115) - Update the WebServer Nginx to fix the latest Security Vulnerabilities.(SCGCQ01452493) - SAS3 Ph8 --- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00729472) - LSA Client: Handle Progress events without initiating individual API calls.(SCGCQ01416371) - LSA: Make operation call with query parameter.(SCGCQ01424479) - Add Test Link Diagnostic API.(SCGCQ01436268) - WG: Landing page - Graphics improvements.(SCGCQ01401517) -.(SCGCQ01412749) - Support for FW ER:SCGCQ01389581 in LSA Client.(SCGCQ01428113) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01563340) - LSA7.3: LSA to hide the Empty back plane based on the property field in the LSA.conf file.(SCGCQ01312022) - LSA: Make operation call with query parameter.(SCGCQ01416374) - Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045) - SCGCQ01250909 - [Lenovo Purley] - Retrieve Boot Events and Maintain it as part of Event History.(SCGCQ01291488) - Client: EPMR12 porting to MR7.3.(SCGCQ01304973) - Client: Provide pending profile details in LSA.(SCGCQ01331947) - LSA Server: EPMR12 defect/feature porting to MR7.3.(SCGCQ01307382) -.(SCGCQ01356193) -.(SCGCQ01375857) - WG: In Remote discovery page Self server is always listed in the last.(SCGCQ01378666) -.(SCGCQ01472631) CSETActivities: - VMware LSI Out of Box driver feature reconciliation.(SCGCQ00696009 port of SCGCQ00652798) - Provide a StoreLibIR2 deb package to work on Ubuntu.(SCGCQ00795333 port of SCGCQ00630108) - WG: No Units are displayed for Event ID: 545: Information about super cap health.(SCGCQ01297685 port of SCGCQ01291338) - LSA throws inappropriate error while attempt to start controller firmware upgrade when pinned cache present on controller.(SCGCQ01297819 port of SCGCQ01288364) - CSCvd88927 - LSA is displaying drives' type string inconsistently for HDD/SSD so it needs to display consistently.(SCGCQ01331599 port of SCGCQ01316465) - Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336569 port of SCGCQ01313804) - Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337104 port of SCGCQ01332737) - Hercules LSA : Schedule CC button does not allow to click on the whole button.(SCGCQ01339214 port of SCGCQ01337027 ) - PR on all drives are not aborted properly until page refresh is done.(SCGCQ01342568 port of SCGCQ01340808) - No. of steps shown in "Modify Drive Group" page is not correct.(SCGCQ01343651 port of SCGCQ01341921) -.(SCGCQ01345364 port of SCGCQ01342479) - Foreign Import page shows wrong data for the importable LD's.(SCGCQ01345398 port of SCGCQ01332912) - LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347171 port of SCGCQ01346904) - LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347220 port of SCGCQ01346908) - LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347221 port of SCGCQ01346908) - Cisco_HSW_Validation_LSA: "Simple Configuration" page that appears after creating a simple config is blank.(SCGCQ01347224 port of SCGCQ01345554) - Cisco_HSW_Validation_LSA: Character limit warning for VD name is not shown while modifying the VD during VD creation.(SCGCQ01347232 port of SCGCQ01345557) - Cisco_HSW_Validation_LSA: VD Size limit check is not working when user modifies the value of the size.(SCGCQ01350834 port of SCGCQ01346906) - Cisco_HSW_Validation_LSA: Prepare for removal menu is still displayed even after the option is selected and event is updated.(SCGCQ01350837 port of SCGCQ01338290) - "%" symbol followed by integer value should not be allowed for the user to enter the size during VD creation.(SCGCQ01350844 port of CGCQ01349556) - Page scroll doesn't work after VD creation when BG processes on VD are expanded in LSA page.(SCGCQ01351383 port of SCGCQ01349487) - VD creation fails when a partial VD is added with decimal value & with 1MB strip size to an existing DG.(SCGCQ01354306 port of SCGCQ01348005) - Security Key provided for importing Foreign Config is not taken by LSA.(SCGCQ01369266 port of SCGCQ01331016) - Unexpected sense PD messages are flooded in storage log when drive is in spun dwon mode.(SCGCQ01369267 port of SCGCQ01264499) -.(SCGCQ01375259 port of SCGCQ01373451) - LSA: Client should not show Unlock drive option if no drives are in locked state.(SCGCQ01378557 port of SCGCQ01331121) - LSA Server: Windows Make file check-in.(SCGCQ01384621 port of SCGCQ01384618) - RWC3 Package: Check-in of SL-IT to the package folder.(SCGCQ01384895 port of SCGCQ01384890) - Cisco_LSA: 'vdname' parameter is missing in the event description that is generated whenever a volume property is modified.(SCGCQ01387017 port of SCGCQ01350435) - Disabled Phy is not populated from the server when we fire /phys uri.(SCGCQ01389917 port of SCGCQ01389892) - SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01389918 port of SCGCQ01385340) - HPE: Un-installation is not removing the folder(s) after performing the Download Diagnostics operation.(SCGCQ01389925 port of SCGCQ01385453) - WG: Message displayed after flashing the controller FW has to be modified for better presentation - Enhancement.(SCGCQ01391318 port of SCGCQ01389483) - Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01419753 port of SCGCQ01417215) - WG: LSA takes some time (2-3 min) in order to display the remote server page after multiple service restarts.(SCGCQ01440910 port of SCGCQ00903348) - MR 7.3.1_LSA fails to find server when there is no network.(SCGCQ01500133 port of SCGCQ01482320) - Cisco - CSCvh55470 - LSA should display proper message for ESXi after LBP/Talladega firmware upgrade/downgrade.(SCGCQ01566052 port of SCGCQ01562368) - SWR: Device ID is not displayed in LSA..(SCGCQ01566241 port of SCGCQ01564621) - Changing ini file name to storelibconfit.ini.(SCGCQ01275670 port of SCGCQ01275496) - For phys-schema.json fails for "([0, u'properties', u'isEnabled', u'enum'], 'False ...".(SCGCQ01309844 port of SCGCQ01304900) - LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01323613 port of SCGCQ01284395) - LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324865 port of SCGCQ01260226) - LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01338337 port of SCGCQ01331755) - Hercules LSA : Cachecade SSD caching should be "enabled" under controller properties.(SCGCQ01339133 port of SCGCQ01337029) - Hercules LSA : WB and AWB description in LD create page not proper.(SCGCQ01339213 port of SCGCQ01337026) - User couldn't enter his value in seconds for locating a physical drive.(SCGCQ01344082 port of SCGCQ01332742) - Cisco_HSW_Validation_LSA: Tooltip for "Simple Configuration" is not shown when other options displays it.(SCGCQ01347225 port of SCGCQ01346851) - Cisco_LSA: Hyperlink symbol can be shown for "Compare and select" link in Modify Drive Group.(SCGCQ01350847 port of SCGCQ01348107) - Cisco_HSW_Validation_LSA: Naming convention can be made same across all "Virtual Drive Erase" forms.(SCGCQ01350850 port of SCGCQ01347250) - cosmetic changes required in "Advanced configuration" page.(SCGCQ01350851 port of SCGCQ01347253) - DG health is not populated properly in cisco cards.(SCGCQ01350892 port of SCGCQ01349625) - Virtual Drive Erase form is not closed when it is opened for the second time.(SCGCQ01351381 port of SCGCQ01347243) - While adding drives to any raid group, Displaying no. of available drives and selected drives can be fine tuned.(SCGCQ01351385 port of SCGCQ01348115) - Cisco_LSA: "Background Initialization" is misspelled in Event description & one more cosmetic change is required.(SCGCQ01351454 port of SCGCQ01348041) - In case of FW upload, LSA crash seen with big FW version name.(SCGCQ01351457 port of SCGCQ01338340) - LSA Client: During the exclusion of the VDs from deletion of one VD leading to the deletion of all the VDs.(SCGCQ01354432 port of SCGCQ01344115) - WG: Error message is not proper if the username is not provided while verifying server in Manager server page.(SCGCQ01387009 port of SCGCQ01379795) - Hercules:LSA:Observe that instead of "Feedback " it is named as "FeedBack ".(SCGCQ01389091 port of SCGCQ01388943) - Updated PD firmware version is not reflecting even after LSA refresh.(SCGCQ01392422 port of SCGCQ01382013) - SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01393239 port of SCGCQ01385340) - Hercules LSA: "Prepare for removal" feature should be disabled for drives in LSA.(SCGCQ01401490 port of SCGCQ01396735) - Activity to check-in build files.(SCGCQ01514879 port of SCGCQ01514834) -.(SCGCQ01520055 port of SCGCQ01508528) - Activity to check-in AutoBST files to new MR 7.5 streams.(SCGCQ01564703 port of SCGCQ01564674) - Updating readme file.(SCGCQ01294583 port of SCGCQ01294570) - For spares-schema instance validation failed for "u'foreign' is not one of [u'NATIVE', u'FOREIGN', u'MIXED']".(SCGCQ01311504 port of SCGCQ01309617) - LSA server:LSA not showing the server reboot message after profile set.(SCGCQ01316473 port of SCGCQ01316342) - HSW_testing_LSA : Could not initialize a VD after disabling and enabling again "Initialize" option.(SCGCQ01321339 port of SCGCQ01309783) - Cisco_HSW_Validation_LSA : Expand option can be taken off for degraded R5 volume.(SCGCQ01337071 port of SCGCQ01332737) - Cisco_HSW_Validation_LSA: Size range warning is not shown when user is giving value beyond the limit in MB unit.(SCGCQ01352603 port of SCGCQ01352603) - LSA not allowing to create RAID with 1M strip using 4K drives.(SCGCQ01369283 port of SCGCQ01284395) - RWC3 Automation Script files check-in.(SCGCQ01385008 port of SCGCQ01384997) - LSA/RWC Automation batch files check-in.(SCGCQ01386218 port of SCGCQ01386214) - Hercules:LSA: trying to open in new tab : "Copyright @ 2017 by Avago Technologies. All Rights Reserved" loads blank page.(SCGCQ01389089 port of SCGCQ01386140) - Adding tape drive support to Unified LSA for IT Ventura controllers.(SCGCQ01389588 port of SCGCQ01352480) - SCGCQ01385340: Health is not coming proper after foreign config import.(SCGCQ01392429 port of SCGCQ01385340) -.(SCGCQ01392506 port of SCGCQ01391775) - [Lenovo 17B] - LSA- Selected Firmware version doesn't match while upgrading the FW.(SCGCQ01420040 port of SCGCQ01417199) - Hercules:LSA: Multiple OLH links are opening when clicked on Advance configuration( IE Browser).(SCGCQ01429992 port of SCGCQ01415979) - LSA Linux BST Automation scripts.(SCGCQ01466009 port of SCGCQ01447013) - operations-schema.json fails for "u'percentage' is a required property..." in xSDS mode.(SCGCQ01297806 port of SCGCQ01291332) - Hercules LSA : Auto refresh not happening on Enclosure push pull with 64 VD's configured.(SCGCQ01297821 port of SCGCQ01276760) - SCGCQ01309545: WG: Issues pertaining to Event ID: 545: Super Cap Health event has redundant data, missing comma's.(SCGCQ01332698 port of SCGCQ01309545) - Foreign Import page shows wrong data for the importable LD's.(SCGCQ01338335 port of SCGCQ01332912) - Cisco Validation: FW throws an exception while scheduling Consistency check on R1.(SCGCQ01347254 port of SCGCQ01340788) - VD size is created with improper size when user creates volume by first decreasing and increasing the size in MB unit.(SCGCQ01350833 port of SCGCQ01346860) - WG: Hide all Vd's in a DG is not working when there is Erase operation is in progress in one of the VD in the same DG.(SCGCQ01395078 port of SCGCQ01394281) - Wrong API populated for enclosures operations and schema will fail.(SCGCQ01445408 port of SCGCQ01444689) - WG: LSA events displays invalid details for unexpected sense events.(SCGCQ01447743 port of SCGCQ01445719) - WG: the controller operations Query param : 4 has 'premium feature' and 'pinned cache' URI's GET calls in response.(SCGCQ01458204 port of SCGCQ01443879) - Cisco - CSCvg96681 - LSA-3.163 should display proper message after logout.(SCGCQ01531153 port of SCGCQ01521114) - MR/IR: Controller Device ID value mismatch in LSA.(SCGCQ01566055 port of SCGCQ01564622) - Hercules_LSA: Event ID-565 does not have any description, shows 0.(SCGCQ01336556 port of SCGCQ01313804) - LSA: LSA should ignore the BBU/SuperCap VPD info failures as it is not a mandatory information.(SCGCQ01347125 port of SCGCQ01346904) - Cisco_HSW_Validation_LSA: Credentials asked during login is not proper when login mode is set to 'Domain Login'.(SCGCQ01347233 port of SCGCQ01341930) - Hercules-LSA : Updated PD firmware version is not reflecting automatically.(SCGCQ01393283 port of SCGCQ01392496) - Hercules:LSA: Linux RHEL 6.9: View Event Logs Icon display not proper.(SCGCQ01414738 port of SCGCQ01409445) - Hercules LSA: Reference to "drive group" while adding logical drive to existing array.(SCGCQ01444720 port of SCGCQ01444670) - LSA: During the installation "Range of Events" selection is not reflecting in the LSA.conf file.(SCGCQ01472166 port of SCGCQ01472048) - SCGCQ01479375: LSA WebGui: "logs.txt" is generated in logs directory after fresh installation in Linux.(SCGCQ01480902 port of SCGCQ01313228) - Fixed: Drive group Migration was disabled with NVME drives DG.(SCGCQ01313228 port of SCGCQ01289586) - LSA pops-up (504 : Gate Time-out) with StorCLI script to start-stop locate drives with JBOD-Hotspare conversion on.(SCGCQ01324864 port of SCGCQ01260226) - Spare URI does not respond on iMR Invader.(SCGCQ01378677 port of SCGCQ01376605) - [PA_2017B_SDV_Lenovo_x3650 M4_Storage] LSA tool update FW Image (oss: 75871) Failed for N2225 SAS HBA(Outback-2) card.(SCGCQ01408778 port of SCGCQ01408626) - In Standalone LSA periodic automatic refresh is not happening. To display the latest status do manual refresh.(SCGCQ01411632 port of SCGCQ01397546) - Hercules LSA : LD properties shows Cachecade Enabled after disabling cache cade.(SCGCQ01417213 port of SCGCQ01415347) -.(SCGCQ01417223 port of SCGCQ01375862) - LSA: Make operation call with query parameter.(SCGCQ01423429 port of SCGCQ01416374) - MR7.3_Focused Regression_Strange character when exceeding max number of Uncof good drives on iMR.(SCGCQ01427110 port of SCGCQ01419325) - LSA: Upgrade of OpenSSL binaries to openssl-1.0.2n.(SCGCQ01564577 port of SCGCQ01563340) - LSA crashed on pulling out 23 drives connected with 64 LD's in multiple controllers.(SCGCQ01345397 port of SCGCQ01331755) - Selected firmware version is coming empty for IR/IT/IMR controller.(SCGCQ01354345 port of SCGCQ01321474) - Hercules LSA: Default write policy for R1 CC VD should be WB instead of WT.(SCGCQ01401352 port of SCGCQ01397557) - [Lenovo 18A] 110340 - [PA_2017B_SDV_Lenovo_Red_Reno_Storage] Use LSA to configure M5225 and it fail to create VD's from LSA.(SCGCQ01424599 port of SCGCQ01421451) - Hercules- LSA : VD access policy not showing as blocked for SVD on CC VD offline.(SCGCQ01443687 port of SCGCQ01442554) - Phase 2 changes for Linux VBAS automation script.(SCGCQ01460081 port of SCGCQ01455968) - LSA : Silent installation is accepting the invalid options also for LSA/HPE/RWC3.(SCGCQ01472265 port of SCGCQ01389392) - CSCvd28635: LSA throws inappropriate error while attempt to start patrol read on virtual drive with SSDs.(SCGCQ01319398 port of SCGCQ01284997) - WG: Trying to import Encrypted VD with Drive security disabled results in error code: 0x11005, it provides No Details to user.(SCGCQ01332824 port of SCGCQ01325783) - To resolve the merge conflict.(SCGCQ01348161 port of SCGCQ01348057) - Port Info disappears on doing Drive push pull.(SCGCQ01404636 port of SCGCQ01379323) - Upgrade of OpenSSL binaries to openssl-1.0.2l.(SCGCQ01444595 port of SCGCQ01444590) - LSA Windows BST Automation scripts.(SCGCQ01472059 port of SCGCQ01460401) - LSA 7.6:LSA does not provide the Stop rebuild option in the action pane once the rebuild operation is in progress in Rhel 7.4.(SCGCQ01557665 port of SCGCQ01555955) 3.023.000.000 - Moderate Impact ------------- 2.085.000.000 - Moderate Impact ------------- - Fixed issue where logs incorrect when remove/insert hdd (SCGCQ01246085) - Fixed Invalid Server Id as part of event, if server is not in network (SCGCQ01261779) - Fixed issue where moving PD from slot 0 to another slot, PD slot ID usually still show slot 0 and slot format (SCGCQ01264554) - Fixed issue where external enclosure serial number in not consistent between LSA, MSM and storcli (SCGCQ01268914) - Fixed issue where LSA does not list Raid 10 as configurable raid level under configuration service uri when drive mixing is allowed (SCGCQ01037806) - Fixed issue where Incorrect configurable Volume sizes displayed in LSA for Raid 0(SCGCQ01039518) - Fixed issue where LSA is not un-installing through the Uninstall-LSA option through Windows All Programs (SCGCQ01039698) - Fixed issue where VD Properties in LSA was not getting populated for default settings (SCGCQ01043610) - Fixed issue where controllers/{id}/spares is not populated correctly (SCGCQ01056900) - Fixed issue where LSA displays only 2 enclosures when four enclosures are connected. (SCGCQ01061548) - Fixed issue where Enclosure more properties displays "Number of Voltage Sensors" as "0" (SCGCQ01063504) - Fixed issue where On Number of Temperature Sensors observe that temperature mentioned has 65535 C. (SCGCQ01063924) - Fixed issue where When the PD is in GHS state LSA is displaying the Prepare for removal option (SCGCQ01064282) - Fixed issue where LSA does not display the access policy 'hidden' in View Event Logs. (SCGCQ01065622) - Fixed issue where schedule patrol -read throws an error 'Invalid URI parameter' when user clicks on Finish button. (SCGCQ01066126) - Fixed issue where Unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01066154) - Fixed issue where LSA crashes while trying to add a VD to the RAID 00 drive group. (SCGCQ01069405) - Fixed issue where Simple configuration fails while trying to create VD using SSD Drive (SCGCQ01069412) - Fixed issue where compared with MSM values of "Date of manufacture" and "Type" is varying. (SCGCQ01069493) - Fixed issue where Unable to clear or import partial foreign configuration from LSA. (SCGCQ01069580) - Fixed issue where Ventura: LSA still displays clear button as active even after successfully importing foreign configuration. (SCGCQ01069616) - Fixed issue where IR3 Events logs are listed reverse sequence in "View Event logs" (SCGCQ01069847) - Fixed issue where LSA Drive Tab PD "Unconfigured Good" count does not automatically refresh when we Move UG PD to JBOD and vice versa(SCGCQ01069852) - Fixed issue where Modifying the VD during the VD creation results in option for user to allow more than one cachecade VD, Creation fails (SCGCQ01069898) - Fixed issue where Instance validation fails for Clear Drive, Stop Clear Drive, Prepare & Undo prepare for removal due to "parameters":{}" (SCGCQ01070441) - Fixed issue where Instance validation fails for Manage Power Save Settings, Controller PUT operation (SCGCQ01070690) - Fixed issue where Instance Validation fails for Schedule Consistency Check (SCGCQ01070739) - Fixed issue where Instance Validation fails for Physical Devices GET (IT controller) (SCGCQ01074960) - Fixed issue where Server not found warning message is displaying repeatedly one over the other (SCGCQ01075026) - Fixed issue where Backplane information not displayed under view server profile (SCGCQ01075841) - Fixed issue where if config cleared during reconfiguration, progress bar does not clear(SCGCQ01075843) - Fixed issue where hide on DG is not automatically updating the access policy of VDs (SCGCQ01076009) - Fixed issue where LSA Crashes when we run API performance Script ususally when performing PD Operations GET in Large config (240 PD)(SCGCQ01076023) - Fixed issue where "Controller Info" of LSA displays driver version of the Gateway server instead of displaying the driver of Vmware server (SCGCQ01076031) - Fixed issue where "Application Version" in server profile page is displayed as "LSA Server null". (SCGCQ01076146) - Fixed issue where there were multiple extra columns in PD tab (SCGCQ01077452) - Fixed issue where the Physical devices are listed in Decreasing order of Device ID instead of ascending order in drive tab (SCGCQ01077563) - Fixed issue where firmware update does not happen in the Direct agent system from Gateway (SCGCQ01077677) - Fixed issue where Manage Power save settings with input of " 1 hour" fails with an error " Input Parameters are Invalid" (SCGCQ01078509) - Fixed issue where Managed Server page provides option of adding gateway server from which we have already logged in to manage server (SCGCQ01078524) - Fixed issue where Feedback is displayed as FeedBack in LSA. (SCGCQ01079092) - Fixed issue where After adding server in Manage Server Page intermittently get a junk screen (SCGCQ01079698) - Fixed issue where back button does not work in case of Advanced Configuration During VD Creation (SCGCQ01079912) - Fixed issues pertaining to "Set Patrol Read Properties" Number of PD Count allowed for patrol read (SCGCQ01080265) - Fixed issue where after logging out from server that is been managed. Clicking Server again in managed server page LSA asks for credentials (SCGCQ01080448) - Fixed issue where Instance Validation fails for PROGRESS related Operations (SCGCQ01082194) - Fixed issue where Instance validation fails for "/controllers/0/operations/security" URI : Controller Operation POST (SCGCQ01082618) - Fixed issue where inappropriate error message is displayed in LSA on flashing fw on IT Intruder (SCGCQ01082897) - Fixed issue where LSA page does not automatically refresh when PD moved from UG bad to UG Good SS page, CC page does not give option (SCGCQ01083060) - Fixed issue where on clicking save button on mail server page its shift to Alert Settings without saving that page. (SCGCQ01083063) - Fixed issue where LSA does not show the default power save mode time set in mfc (SCGCQ01083106) - Fixed issue where after adding server the managed server list, then logging out, new server cannot be logged into. (SCGCQ01083226) - Fixed issue where LSA service is not present in the Windows services after downgrading LSA. (SCGCQ01084774) - Fixed issue where Event Response is giving Default Write Policy: abc (SCGCQ01043609) - Fixed issue where Sending Invalid HTTP verb in the request for an URI fails with 404 instead of 405 (SCGCQ01059216) - Fixed issue where texts linked to the health icons "optimal", "critical", "needs attention", in server summary page Should be clickable (SCGCQ01063432) - Fixed issue where LSA still displays physical disk actions and properties menu when no pd is selected after sorting from Enclosure/slot. (SCGCQ01063524) - Fixed issue where Instance Validation fails for Simple Configuration POST (SCGCQ01064737) - Fixed issue where consistency check Schedule parameters is available even after selecting the "Disable" from the Consistency check mode (SCGCQ01069825) - Fixed issue where LSA not accessible through Chrome browser Version 48.0.2564.109 m (SCGCQ01078618) - Fixed issue where while initiate ISE against 3rd party locked UG drive, XHR_Header code says "POST 200" but XHR_Response says "Er 77" (SCGCQ01080402) - Fixed inconsistency between the VD properties displayed in STORCLI when compared with other Apps. (SCGCQ01081145) - Fixed issue where LSA doesn't get updated without a service restart on Vmware server with IR3 controller. (SCGCQ01081324) - Fixed issue where matching error description is not shown by client when there is a session already active during login. (SCGCQ01063542) - Fixed issue where LSA login attempt failed for Vmware Server (SCGCQ01064784) - Fixed issue where 002.010.000.000 build (Gateway & Standalone) is unable to discover server (SCGCQ01069396) - Fixed issue where replace drive table does not have device Id column (SCGCQ01075112) - Fixed issue where LSA does not update the data automatically when Delete VD is performed. (SCGCQ01079635) - Fixed issue where RWC3-LWM (Windows) is unable to send mail to SMTP (SCGCQ01173361) - Fixed issue where Ventura IT drive push and pull needs services restart to update the count (SCGCQ01066048, Port of SCGCQ01064904) - Fixed issue where LSA Allows JBOD Drive having OS to be converted to UG drive, doesnt notify the user on the OS present on JBOD (SCGCQ01067253, Port of SCGCQ01052412) - Fixed issue where LSA displays "error:Not all values are set successfully" while trying to save power save settings on IMR Ventura. (SCGCQ01067711, Port of SCGCQ01057457) - Fixed issue where LSA shows blank screen after log in with mutiple controller in the setup (SCGCQ01069360, Port of SCGCQ01068813) - Fixed issue where intermittent update Ventura firmware hang using LSA ( StorCLI is OK ) (SCGCQ01069565, Port of SCGCQ01038421) - Fixed issue where user unable to migrate from secured Raid1 VD to Raid5/Raid 6 VD on LSA (SCGCQ01070807, Port of SCGCQ01066154) - Fixed issue where all the events are not getting downloaded while downloading log from LSA (SCGCQ01145261, Port of SCGCQ01139334) - Fixed issue where no error message is displayed while importing secure EPD through wrong key (SCGCQ01066088, Port of SCGCQ01063911) - Fixed issue where user unable to clear or import partial foreign configuration from LSA. (SCGCQ01085466, Port of SCGCQ01069580) 2.030.000.000 - New Function Only/No fixes -------------
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
StorCLI (Command Line) Utility for Storage Management Adapters Supported: ThinkSystem RAID 530-8i PCIe 12Gb Adapter (7Y37A01082) ThinkSystem RAID 530-4i Flex Adapter (7M17A03932) ThinkSystem RAID 530-4i Flex Adapter (7M27A03918) ThinkSystem RAID 530-8i Dense Adapter (SD530 RAID) ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727) ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter (7Y37A01083) ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter (4Y37A09722) ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (7Y37A01084) ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085) ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086) ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (7Y37A01087) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M17A03933) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M27A03917) ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721) ServeRAID M1210 SAS/SATA Controller (00JY194) ServeRAID M1215 SAS/SATA Controller (46C9114) LSI SAS3004 RAID (NA-SAS3004-B) LSI SAS3004 RAID (NA-SAS3004-N) ServeRAID M5210 SAS/SATA Controller (46C9110) ServeRAID M5225-2GB SAS/SATA Controller(00AE938) ServeRAID M5215 with 2GB Flash Enablement Flex System x240 M5 (00JX142) ServeRAID M5210e SAS/SATA Controller (46C9117CTO) ServeRAID M5120 SAS/SATA Controller (81Y4478) IBM Flex System Storage Expansion Node (68Y8588) ServeRAID M5115 SAS/SATA Controller for Flex System (90Y4390) ServeRAID M5100 Series IBM Flex System Flash Kit for X6 (44T1178) ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728 ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735 NOTE TO SERVICE - Reference RETAIN #N/A 007.2705.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.27 Defects: Support for 16MB flash in storclif (DCSG01555459 SPDM invalidate on a slot with certificate is deleted/cleared does not return proper failure message (DCSG01200711 In "OTC" command output "phy info" "sasaddress" and vendor name is missing. (DCSG01416857 OTC command not displaying the Version header info when there is a partial failure (DCSG01453843 phyinfo legends are missing in ./storcli /c0/pall show command only for controller (DCSG01464352 autoconfig lowlatency change option is not working (DCSG01225927 Fixing storcli leaks (DCSG01436087 Storclif set clockmode does not return any message in either profile 30 or 32 (DCSG01343704 Storcli download command needs update. (DCSG01385977 Error message and Ctrl_prop needs update (DCSG01366236 Negative value is shown (DCSG01452047 CLI crashes when setting timestamp on all the enclosures (DCSG01275981 Show Drive Smart Info Failed without any error message (DCSG01453497 Fixing storcli leaks and unitialised variables (DCSG01528847 Schema validation fails with Drive details with (DCSG01312383 Removed switch and NVMe fields as part of the phy all show information (DCSG01429974 OTC command out of 2 coredump files only one coredump file is created. (DCSG01430008 Storcli fails to set "Preboottrace" to OFF. (DCSG01407684 Ph27_Storecli:pcie phy information should be displayed in the "storcli64.exe /c0/lnall show" command output. (DCSG01430854 show events command is missing in IT help command list (DCSG01440137 storcli /pall show command fails with "Unable to retrieve PcieIoUnitPage0 information" when executed on HBA (DCSG01451391 set sasadd command runs successfully on Megaraid controller. (DCSG01451336 storcli log file ballooning in size when used as a compare file for controller properties (DCSG01440265 Failure Description for lnx commands in profile 32 not consistent (DCSG01327288 Storcli lists incorrect parameter options (DCSG01480789 New PSOC related properties are not being displayed (DCSG01214343 Storcli legends for "CertProv" is missing in 'storcli show" output (DCSG01230074 OTC command status is shown as failure even after collecting the data (DCSG01462898 As part of phy compare linkspeed command invalid description observed. (DCSG01463047 storcli to allow both del and delete keywords (DCSG01333727 StorcliF and Storcli64 command details are incorrect. (DCSG01431031 Storclif did not show correct 24G drive speed as 22.5Gb/s (DCSG01436600 storcli exits when chunksize is given as 0 (DCSG01441105 StorCLI Add help page for storcli64 /cx/ex set time command (DCSG01266055 StorCLI IT show vpd command gives Json error (DCSG01428172 Help indentation update (DCSG01303723 No reason for the failure during "Alarm: On/off/silence" (DCSG01451915 Multiple drive microcode updates fail if mode is not provided by user. (DCSG01509349 addvirtualdriveeachr0 creates R0 virtualdrive for incorrect drive format. (DCSG01445078 logfile command not working in EFI (DCSG01440821 drive fw download with incorrect fw detailed status not seen and success status message noted (DCSG01192976 Expander firmware download command is getting success without firmware file (DCSG01368730 In "vmware_esxi_8" readme "./storcli64 /c0 set refclk =0" command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01446616 StorCLI phy -events commands (DCSG01452698 Fixing BD HUB reported license issues (DCSG01235456 otc command output some configuration pages are missing. (DCSG01417587 Incorrect details listed during V_D expansion. (DCSG01447578 Disabling PCIe lane is reporting failed/Invalid arguments (DCSG01334639 StorCLI crashes with /pall phyevents in Windows ARM (DCSG01462894 Expander firmware download is failing on enclosure behind IT using storcli (DCSG01360586 get otc command is failing in Linux when multiple coredump is present (DCSG01437688 scrutiny vib file version name noted wrong (DCSG01456900 VD creation is successful with PD in JBOD state (DCSG01186039 set time not listed in IT help / schema mapping list gives success message (DCSG01455624 Storcli set vpd command does not return any result, either pass or fail (DCSG01441368 volume table is not listed in sorted order for "cx show all " command (DCSG01187424 Heading of SAS and IOC pages in otc command are displayed wrong and Size in DB Register (DCSG01417593 Storcli fails with segmentation fault while query for enclosure and drive (DCSG01277632 Storcli shows no failure Description for "restart" operation. (DCSG01303781 refclk " command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01456786 Storcli does not have ESXi 8.x binary release and ESXi 6.x support mentioned in Readme. (DCSG01361836 'esxcli storcli controller get snapdump ' fails with syntax error (DCSG01464430 Storcli shows wrong information in DG details when JBOD/System is present (DCSG01521782 EFI StorcliO VPD update/flash fails (DCSG01559387 Changing of reset phy eveent commands to phy errorlogs (DCSG01448647 Lane information does not have the legends in the output (DCSG01445839 Description for PSOC flash from storcli is not proper when "resetnow" is used (DCSG01221186 There is no error message for lane show info command for lane number 16. (DCSG01446504 Return value for setting of large CCDelay does not match (DCSG01442317 issues with Consistency check delay and schema (DCSG01542373 StorCLI diag cmd returns successfully on M.2 Ctrl, even the Ctrl Firmware show not supported on iMR (DCSG01444219 Storcli needs update in error message and in detailed description. (DCSG01525040 observing "File read error !!!" while downloading enclosure firmware in UEFI shell (DCSG01521747 EGS: Storcli -Next Learn time in /cx show all differs with actual /Cv show time (DCSG01180101 Show drive command status shows failure with description "Show drive information failed", however show all status shows success with description "Show drive info (DCSG01462887 Storcli does not list proper "required" fields while creating V D using "addvdcachecade" option. (DCSG01453731 Storcli crashes during "debug level" set. (DCSG01361819 One of the element status displayed wrongly with extended status command (DCSG01372738 For the PI drives storcli64 shows PI as 'No' whereas LSA shows PI as capable (DCSG01395078 displaying proper description while setting invalid refclk. (DCSG01356146 Json schema support for StorCLI phy show command (DCSG01428869 Storcli shows output for invalid Lane. (DCSG01409017 Storcli "Enclosure" set time command needs update (DCSG01408981 All db commands are failing once after unregister the trace buffer. (DCSG01444766 Storcli returns missing char invalidate cmd output (DCSG01376779 Storcli shows duplicate information in readme files. (DCSG01323236 storcli phyevets is showing succss while executing on Mega RAID Controller (DCSG01464454 Storcli exits without returning anything on trying to set aso key with characters more than 127 (DCSG01409627 BGOP'S operations error message is inconsistent (DCSG01230073 Delete error-counters is not actually clearing the error counters (DCSG01416763 In windows OTC command output "capturing log serial number for the RTT Trace Buffer.." displays wrong. (DCSG01444337 Error message noted wrong with mode f command (DCSG01377687 Storcli shows success instead of failure for "show expansion" operation (DCSG01481384 Sending wrong image to controller has different message (DCSG01524642 output is jumbled for the eghs command output (DCSG01440963 Plugin for "start/stop/resume/pause" for consistency check and patrolread does not work. (DCSG01451161 Unable to set DS options. (DCSG01380122 In "vmware_esxi_8" readme "./storcli64 /c0/pall show phyevents " command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01462816 Transform iMR command is mapped to incorrect esxcli command (DCSG01453766 otc commnad output "phy_info" data phy no 3 enable bit shows "N" Enbl bit instead of "y" in compare "storcli64.exe /c0/pall show" command . (DCSG01430015 Spaces are important (DCSG01303433 Lane information legends are missing in ./storcli /c0/lnall show command only for controller (DCSG01464343 For IT controller storcli "show eventloginfo" command output "status" and "description" displays wrong. (DCSG01448384 Using latest storecli "set refClk" command fail with error message. (DCSG01368858 Storcli Virtual drive creation should fail with "reusetargetid" parameter. (DCSG01430905 While executing "get otc" command there is no "storcli" version number displayed. (DCSG01437154 system time sync'up fails for expander with storcli command (DCSG01271785 PSOC hardware version is not displayed in storcli output. (DCSG01317465 (Port Of Defect DCSG01325851) While executing Enclosure Status cli displays wrong values. (DCSG01528830 (Port Of Defect DCSG01531725) storcli in Linux occasionally causing coredumpctl (DCSG01489233 (Port Of Defect DCSG01552077) autoconfig lowlatency change option is not working (DCSG01225927 (Port Of Defect DCSG01228069) Not able to get snapdump with -s=all option (DCSG01447404 (Port Of Defect DCSG01447574) Created 100 MB virtual drive with 1024K strip size on 4K sector size target device but the created size is 96MB (DCSG01320102 (Port Of Defect DCSG01329183) Using cachevd option returns that volum creation fails, but the volume is actually created (DCSG01432157 (Port Of Defect DCSG01432522) Storcli commands shows "Not enough memory to continue." with a page option. (DCSG01255030 (Port Of Defect DCSG01267413) Unable to create R0 V D's using "addvdeachr0" (DCSG01450023 (Port Of Defect DCSG01453727) VD creation is successful with PD in JBOD state (DCSG01186039 (Port Of Defect DCSG01187950) Physical drives count mismatch is there if compared with the actual drives present when tape drive is connected (DCSG01491544 (Port Of Defect DCSG01493435) Storcli crashes while Upgrading PSOC image for IT card (DCSG01446520 (Port Of Defect DCSG01490408) Set linkspeed operation asks for system reboot when the operation fails. (DCSG01554840 (Port Of Defect DCSG01557410) VD table is not listed in sorted order for "cx show all " command (DCSG01187424 (Port Of Defect DCSG01187947) In set security command help, file=filename is shown, but does not seem to work. (DCSG01432351 (Port Of Defect DCSG01437189) Multiple Cli2 observations w.r.t command returning success for incorrect syntax, blank Volum size etc. (DCSG01466254 (Port Of Defect DCSG01466530) EnhancementRequests: Enhancing the enclosure download command to read chunk size as input (DCSG01191253 Storcli Support for UBM6 backplane (DCSG01238774 Support for PsoC catalog version checking on update. (DCSG01245656 Create security lock key using EKMS (DCSG01311276 Port of ScrutinyCLI commands to StorCLI (DCSG01415106 Add PERST control for NVMe drives (DCSG01400121 Prevent installation of inappropriate Firmware image (DCSG01421212 VMware ESXi 8.0 OS Support Tool chain migration (DCSG01176442 Allow CLI to run on perc branded cards (DCSG01219438 add PERST control mechanism for NVMe Physical Disks (DCSG01421205 Implement REFCLK control in storcli (DCSG01291369 Security Version Support on 96xx boards (DCSG01174566 Remove the check for heterogenous config and allow the user to change the link config irrespective of homogenous or heterogenous. (DCSG01171914 Add a new StorCLI command to "show all" faster (DCSG01303802 Need 95xx boards to perform equally or better than Invader when only slower RAID volumes comprised of SATA HDDs are attached. (DCSG01272082 SecureBoot: FW download operation fails with incorrect message (DCSG01132479 Time-sync between Host-Utilities and all the Expanders in the topology (DCSG01214261 95xx HBA controllers Support for multiple PSOC images (DCSG01203368 Remove PERST support from refclock commands for IT cards (DCSG01388007 Handling MPI blocked functions. (DCSG01373043 Port of ScrutinyCLI commands to StorCLI (DCSG01390110 Removing "PSOC Version" field from the controller detailed command (DCSG01270804 Support Drive drive image without using Host Memory (DCSG01454023 Allow reusing of TargetIDs without 120 seconds delay in the factory and test environment (DCSG01394604 VMware ESXi 8.0 OS Support (DCSG01258042 OS_Utils: The 'Device Speed' is shown as 24.0Gb/s for SAS4 drives (DCSG01388208 De-branding of OEM name from StorCLI (DCSG01312376 ESXCLI Plugin support with DSDK migration (DCSG01431017 Displaying PackageVersion for Aero-IT Images (DCSG01191525 Storcli: Implement REFCLK control (DCSG01232268 Hide nonvolatile key option in for temporary key option (DCSG01325680 (Port Of EnhancementRequest DCSG01328968) ESXCLI Plugin support with DSDK migration (DCSG01475599 (Port Of EnhancementRequest DCSG01483012) SAS-4 JBOD integration with RAID controllers (Harpoon) (DCSG01364599 (Port Of EnhancementRequest DCSG01373126) Move from 7.22 to 7.24 channel base for the R2 program (DCSG01345495 (Port Of EnhancementRequest DCSG01352227) OEM requesting FIPS support on Linux (DCSG01315666 (Port Of EnhancementRequest DCSG01507167) CLI to display the energypack serialNo content in decimal format (5 digits including leading zero) for Supercap (DCSG01452070 (Port Of EnhancementRequest DCSG01455486) Add a new StorCLI command to "show all" faster (DCSG01303802 (Port Of EnhancementRequest DCSG01453526) - (DCSG01064409 (Port Of EnhancementRequest DCSG01085133) 007.2206.0000.0000- Moderate Impact/Low Probability of Occurrence -------------------- MR 7.20 Defects: -Storcli : Copyright shows as year 2021 instead of 2022 & also build release year 2021 instead of 2022 & also build release year shows as 2021 instead of 2022.(DCSG01124638) -Error seen while flashing psoc.rom in efi CLI.(DCSG01131584) -storcli 7.2001 does not return values for a bad drive.(DCSG01052072) -Spellling of mismatch is displayed as "Missmatch" in "Encryption type missmatch" error message..(DCSG01091937) -Device Type for Backplane in Alilog shown as Enclosure.(DCSG01109911) -Storcli shows Protection Information (PI) capable drive i.e. "PI eligible" as No, however LSA shows it properly.(DCSG01145223) -CLI not iterating through MR_SAS_CONNECTORS for H750 controllers.(DCSG01077564) -Instance validation fails for "/c0 show all" and "controller-detailed-properties-schema.json".(DCSG01035798) -OS drive name shown as N/A for multiple VDs.(DCSG01101813) -Storclif reports BBU instead of cachevault for failed retention tests.(DCSG01092227) -Storclif 7.2005 can't start retention test, says No CacheVault Found!.(DCSG01130532) -Enclosure logical ID field is not displayed for BP connected to connected to Boca 540-16i controller.(DCSG01024654 (Port Of Defect DCSG01024693)) -Set Patrolread command hangs while setting "excludevd".(DCSG01101780 (Port Of Defect DCSG01102890)) -Strocli.efi utility got hung on issuing "storcli /c0 show" command.(DCSG01049757 (Port Of Defect DCSG01050540)) -"storcli /call show" shows jumbled drives in a Multi IT controller environment.(DCSG01040245 (Port Of Defect DCSG01040583)) -PD size displayed in Gib for some of the 4K drives is incorrect..(DCSG00389591 (Port Of Defect DCSG00994728)) -PD Firmware Release Number = N/A is displayed for drive which has valid Firmware Release Number.(DCSG01083763 (Port Of Defect DCSG01083800)) -Storcli shows success without proper description for "VD delete BBMT" command when no VD present..(DCSG01002466 (Port Of Defect DCSG01024694)) -Update splitpackage script for shenandoah.(DCSG00651204 (Port Of Defect DCSG00994744)) -While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883 (Port Of Defect DCSG01036901)) -While trying to import foreign config, Storcli is not showing drive as "Hotspare" if the user has only hot spares.(DCSG01028926 (Port Of Defect DCSG01029835)) EnhancementRequests: -Update ControllerInfo Structure with PartNumber - API Changes.(DCSG01064529) -Request for Win2022 Supportnfor their 16G Enablement launch, March 2022 RTS.(DCSG00977684) -MegaRAID key management feature: volatile key escrow.(DCSG00992844) -secureSignBin: implement feature to download the public key during signing or with explicit arg.(DCSG01035866) -DCSG01082488 -API change to support PD sanitize operations enhancements.(DCSG01070995) -Aero 9560/9580 - Add PSOC6 as Vision Controller.(DCSG01056506) -Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API.(DCSG01065378) -Change the attribute name "Secured" to "Locked" in PD Properties output.(DCSG01040562 (Port Of EnhancementRequest DCSG01040785)) -Handling of VD target-ID's individually even when target-ID is assigned beyond maxLDs.(DCSG01091990 (Port Of EnhancementRequest DCSG01092477)) -Windows Client Win11 OS Support.(DCSG01043616 (Port Of EnhancementRequest DCSG01068906)) 007.1907.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.19 Defects: -While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883) 007.1707.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.17 Defects: -StorCLI listing failed NVMe drives in non-sorted order.(DCSG00320844 -Instance Validation Failed for "/call/fall show all.json" and foreign-configuration-detailed-schema.json.(DCSG00408509 -MR7.16_storcli: VD creation with the remaining drives fails.(DCSG00303606 -Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 -Package Version is not displayed properly after flashing firmware..(DCSG00961822 -PH18 BETA - StorCLI - Update YEAR in the CLI banner.(DCSG00707142 -Storcli launch fails with permission denied message.(DCSG00972016 -Setting CC date and time exceeding the limit, needs to be handled.(DCSG00520110 -"rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337710 -Storcli lists "/ex show all" for "/cx show all" command..(DCSG00417504 -DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00359247 -Storcli: learnStartTime displayed incorrectly in command details.(DCSG00320649 -Storcli /cx set debug reset all help description needs an update.(DCSG00521571 -storcli /cx set flushwriteverify help needs an update.(DCSG00507067 -PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00315152 -PH18 PA - StorCLI - appropriate message needed for erase all excludemfg command.(DCSG00395234 -Storcli shows "success" with incorrect message INSTEAD of syntax error for "/c0/d1 set" command..(DCSG00543505 -storcli show alilog shows "SATA-3G" as device interface for 9361-16i.(DCSG00555672 -Handling PBLP component whild displaying Image component versions.(DCSG00301878 -MR_7.17: After Driver unload/load via DDV tools- Ctrl acces via Storcli exit with Segmentation Fault.(DCSG00426317 -coverity: fixing non-array delete and dereferencing before NULL checks.(DCSG00368376 -Handling the read-only file system from storcli.(DCSG00542683 -Updating new SPDM MPI errors.(DCSG00435039 -"Failed Drive not found" reported from enclosure level show repair command.(DCSG00423496 -Controller Lane show command is not working with individual Lanes.(DCSG00386181 -Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00469639 -VD creation fails from storcli even though free capacity is present in DG.(DCSG00757768 -Aero 7.15 CLI shows a extra space in the /c0 set cc h command.(DCSG00298943 -Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00408497 -show alilog command displays JBOD as volumes.(DCSG00556934 -Instance Validation Failed for "/call/fall import preview.json" and foreign-configuration-detailed-schema.json.(DCSG00408512 -Max commands for averaging needs to be removed from DPMstat RA output.(DCSG00286349 (Port Of Defect DCSG00306711) -Failure observed while running set sbr command.(DCSG00779151 (Port Of Defect DCSG00932922) -Storcli "/call/eall/sall download status" error message needs correction..(DCSG00735452 (Port Of Defect DCSG00757676) -Unified StorCLI MR7.15 - Fixing coverity issues - Part 1.(DCSG00290662 (Port Of Defect DCSG00368612) -Atlas 4.2: StorCLI lists wrong error message "Failed in standard Inquiry", when user tries to upgrade/downgrade all connected NVMe Drives FW at a time.(DCSG00309398 (Port Of Defect DCSG00313432) -The foreign config of DHS/GHS details is not listing under foreign config import preview.(DCSG00919659 (Port Of Defect DCSG00935761) -Invalid Array Size in ZB is displayed for Degraded R1 span Foreign VD in storcli foreign import preview.(DCSG00916209 (Port Of Defect DCSG00935751) -Logical ID of Cobra expander not displayed properly in Storcli and LSA.(DCSG00342456 (Port Of Defect DCSG00391477) -CLI crashes when issuing the phyerrorcounters command on a 14G Expander backplane.(DCSG00323054 (Port Of Defect DCSG00323721) -Show command status not proper when issued with wrong EID.(DCSG00906544 (Port Of Defect DCSG00935762) -Storcli shows no output for valid parameter for "/c0/p0,1,22 show" command..(DCSG00840944 (Port Of Defect DCSG00932927) -From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494 (Port Of Defect DCSG00391509) -Non Foreign drives GHS are listing under Foreign import preview.(DCSG00931210 (Port Of Defect DCSG00935765) -Storcli "show file" command does not report correct FW version.(DCSG00299788 (Port Of Defect DCSG00302030) -Storcli show incorrect property name for "/c0/d0,3 set hidden=off" command..(DCSG00733214 (Port Of Defect DCSG00758467) -Coverity fixing bad allocator and resource leaks.(DCSG00307346 (Port Of Defect DCSG00307355) -Vses Device Type is displayed as Enclosure for IT card.(DCSG00920244 (Port Of Defect DCSG00935772) -StorCLIF fail to flash firmware image of BTBL (BOOT_BLOCK) on Invader MR.(DCSG00330381 (Port Of Defect DCSG00353198) -Storcli throws junk value is shown on set consistency check.(DCSG00906989 (Port Of Defect DCSG00935693) -MR 7.15 StorCLI : Addressing Coverity defects.(DCSG00286677 (Port Of Defect DCSG00311222) -CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802 (Port Of Defect DCSG00935973) -VDs imported from Jbod mode to RAID do not have OS name available in Linux OS.(DCSG00968023 (Port Of Defect DCSG00975216) -CLI failing to stop a BGI or CC when paused..(DCSG00735544 (Port Of Defect DCSG00757870) -Enclosure phyerrorcounters fails in VMware platform.(DCSG00706496 (Port Of Defect DCSG00706497) -Storcli shows success for "set patrolread excludevd" command failure in the presence of VD..(DCSG00906735 (Port Of Defect DCSG00935770) -For empty SPDM slots 0 & 1 show security slot info command shows as Invalid data on IT controller..(DCSG00348125 (Port Of Defect DCSG00353186) -Segmentation fault noted with drive firmware update.(DCSG00758645 (Port Of Defect DCSG00932904) -VD creation output shows VD size as 0KB when it reaches maximum supported virtual disks(64VDs) in a DG..(DCSG00349415 (Port Of Defect DCSG00353914) -SAS drive Inquiry data is not shown in drive show all output.(DCSG00778367 (Port Of Defect DCSG00932917) -Fixing Coverity defects of MR 7.15.(DCSG00299981 (Port Of Defect DCSG00309219) -Post reboot incorrect lane speed is displayed in Storcli when user sets it to 16GT/s.(DCSG00383336 (Port Of Defect DCSG00395901) -On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266888) -Coverity defects - remove resource leaks, invalid types in function arguments.(DCSG00269017 (Port Of Defect DCSG00277861) -Storcli will not show LargeIOsupport is enabled/disabled on the controller.(DCSG00353195 (Port Of Defect DCSG00353882) -Storcli shows target id of the drive as boot drive instead of showing drive slot number for JBOD drives..(DCSG00344079 (Port Of Defect DCSG00353203) -MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282590) -Removed leading spaces for SATA drives.(DCSG00904104 (Port Of Defect DCSG00935692) -Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266881) -Size of Degraded R10 Foreign VD is displayed as 0 KB in storcli.(DCSG00916207 (Port Of Defect DCSG00935746) EnhancementRequest: -Adding new License file and updating the build script to include the new file.(DCSG00324401 -Add CLI command to control Parity Read Cahce Bypass for SSD VDs.(DCSG00342282 -MR7.16 : Support WJ Pinning for both WB and WT Parity RAID VDs.(DCSG00214472 -Provide option in storcli to disable / enable the Preboot trace Buffer feature in MR FW..(DCSG00310366 -Enable cache retention testing on Shenandoah controllers for factory testing.(DCSG00340899 -Updating storcli code and makefiles to support VBAS builds on GCP.(DCSG00412063 -Additional NameSpace behavior changes.(DCSG00310386 -Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 -StorCLI: Automate the test cases specific to MR7.17 Product Requirements.(DCSG00433350 -Add support for reporting SPDM Measurement Specification and Hash Algorithm.(DCSG00301782 -Updating command legends as per the command output.(DCSG00083851 -IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00371061 -MR7.16: StorCLI does not show the SAS Address of the enclosure.(DCSG00255109 -Unified StorCLI 7.17 - x64 UEFI VBAS / GCP support.(DCSG00559813 -Updating Error Strings for NVME init error codes in Apps.(DCSG00434066 -MR7.16 StorCLI: Ruby SED Support.(DCSG00264744 -CLI to handle ERROR_BUSY from Windows storport.(DCSG00348813 (Port Of EnhancementRequest DCSG00353214) -Displaying "OS name" for VDs imported from EHBA mode to RAID.(DCSG00775114 (Port Of EnhancementRequest DCSG00932911) -Display Enclosure serial No in Storcli.(DCSG00500922 (Port Of EnhancementRequest DCSG00932906) -Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00500924 (Port Of EnhancementRequest DCSG00521828) -SEKM Support in CLI.(DCSG00433143 (Port Of EnhancementRequest DCSG00935780) -CLI: Package Stamping Verification During Firmware Update.(DCSG00239672 (Port Of EnhancementRequest DCSG00282815) -StorCLI has the ability to switch the OOB mode.(DCSG00547179 (Port Of EnhancementRequest DCSG00935783) -SMART Polling Improvement - PERC 10.(DCSG00249963 (Port Of EnhancementRequest DCSG00282814) -PERCcli turn off logging by default.(DCSG00255367 (Port Of EnhancementRequest DCSG00282813) -Remove the MFG date, Revision date and Rev from IT StorCLI output.(DCSG00415059 (Port Of EnhancementRequest DCSG00418372) -Display port information for NVMe Init failed drives.(DCSG00359418 (Port Of EnhancementRequest DCSG00421187) -storcli "set good" command can still be used for JBOD EPD-PT drives.(DCSG00318591 (Port Of EnhancementRequest DCSG00353919) -PERC11.1 - Dual x8 Support for 16 port Controllers.(DCSG00299060 (Port Of EnhancementRequest DCSG00323772) 007.1513.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.15 Defects: -CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802) -Handling the read-only file system from storcli.(DCSG00938327 (Port Of Defect DCSG00542683)) Enhancements: -Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00930193 (Port Of EnhancementRequest DCSG00500924)) 007.1510.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.15 Defects: -From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494) -PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00320641 (Port Of Defect DCSG00315152)) -StorCLI listing failed NVMe drives in non-sorted order.(DCSG00321815 (Port Of Defect DCSG00320844) -MR 7.16: Storcli: learnStartTime displayed incorrectly in command details.(DCSG00321908 (Port Of Defect DCSG00320649)) -rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337735 (Port Of Defect DCSG00337710)) -DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00360517 (Port Of Defect DCSG00359247)) -Controller Lane show command is not working with individual Lanes.(DCSG00386184 (Port Of Defect DCSG00386181)) -storcli /cx set flushwriteverify help needs an update.(DCSG00541982 (Port Of Defect DCSG00507067)) -"Failed Drive not found" reported from enclosure level show repair command.(DCSG00430578 (Port Of Defect DCSG00423496)) -Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00489855 (Port Of Defect DCSG00469639)) -Storcli /cx set debug reset all help description needs an update.(DCSG00538790 (Port Of Defect DCSG00521571)) EnhancementRequest: -Display Enclosure serial No in Storcli.(DCSG00500922) -IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00405900 (Port Of EnhancementRequest DCSG00371061)) 007.1326.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects: -Foreign Config Preview shows empty data when Foreign config is present with Rebuild is in Progress.(DCSG00261203) -Inconsist DG number in StorCLI.(DCSG00235157) -RTTdump shows success but it fails to download the dump..(DCSG00253652 (Port Of Defect DCSG00253719)) -Incorrect Adapter type shown in the perccli show all output.(DCSG00241405 (Port Of Defect DCSG00244145)) -Expander firmware download using with mode 5 option fail with error message..(DCSG00239524 (Port Of Defect DCSG00240685)) -With length command, CLI says Memory Exhausted.(DCSG00235628 (Port Of Defect DCSG00236791)) -Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 (Port Of Defect DCSG00286701)) -Observe CLI Crash on windows while setting Autoconfig option.(DCSG00253642 (Port Of Defect DCSG00253722)) -MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282592)) -"No Controller found" shown when controller is busy..(DCSG00248017 (Port Of Defect DCSG00253661)) -On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266886)) -Connector Name is incorrectly displayed when connector count goes beyond 8.(DCSG00249023 (Port Of Defect DCSG00252701)) -MR 7.15: Storcli: Instance Validation Failed for "virtual-drive-config-schema.json" and "/call delete config force".(DCSG00247992 (Port Of Defect DCSG00253761)) -With new MR API changes, storcli shows failure while changing accesspolicy.(DCSG00257307 (Port Of Defect DCSG00258140)) -MR 7.15: Storcli: Instance Validation Failed for "enclosure-fw-download-schema.json" and "enclosure FW download" output..(DCSG00250066 (Port Of Defect DCSG00253733)) -Show expansion shows wrong output in presence of JBODs..(DCSG00247163 (Port Of Defect DCSG00252417)) -Enclosure position value not listed properly in show all command.(DCSG00254935 (Port Of Defect DCSG00256384)) -Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266894)) -Expander firmware download help need to be corrected for IT controller..(DCSG00239870 (Port Of Defect DCSG00240680)) EnhancementRequests: -To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h.(DCSG00256271) -Additional FDE type for Ruby SED support.(DCSG00055878) -MFI SMP Port Num API changes.(DCSG00257777) -MR7 API: Add package incompatibility reporting.(DCSG00231443) -SMART Polling Improvement - API Changes.(DCSG00246317) -Implement customSign.exe CLI wrapper utility to help customers sign with their private key.(DCSG00234646) -Changes to support 16port connection to Expander with AeroIOC.(DCSG00254845) -Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 (Port Of EnhancementRequest DCSG00290359)) 007.1325.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.13 Fix issue: DCSG00235157 - Inconsist DG number in StorCLI Description: Customer reported the DG/Array/Row is incorrect to get from storcli and it causes "insert" command failure. 007.1324.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.13 Defects: -Storcli: Optl not mentioned in /call/dall show output..(DCSG00065740) -Instance Validation Failed for "/call set smartpollinterval=300" and controller-smartpollinterval-schema.(DCSG00057141) -StorCLI crash when create VD.(DCSG00052275) -/e: and /s: is not mentioned in the Convention for /storcli64 /c0/v0 start migrate detailed ?.(DCSG00143788) -BZ(186687):[AMD2P & Whitley] EXSi 7 can't boot up after install storcli.(DCSG00048516) -Storcli show Device type as backplane while no drives are connected.(DCSG00074732) -Help Description for Migrate shows "operation" printed twice in Storcli output..(DCSG00063696) -Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00057213) -Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements - Part 1.(DCSG00046195) -Foreign topology table display BT as "Y" for drives which are in foreign state..(DCSG00068453) -Storcli: Same help description across "/c0/e0 show" and "/c0/e0 show all"..(DCSG00064748) -While executing perccli, by default log file with storcli.log is getting generated..(DCSG00038031) -MR 7.13: Storcli(Regression): Syntax error seen while using "nolog" and "page" together as parameters.(DCSG00071417) -In Aero behind atlas configuration "NVME" drive firmware revision shows wrong.(DCSG00049614) -Storclif command for battery retention test issues command to start retention test which is an unsupported command.(DCSG00058688) -Show DPM with type LCT is not giving proper output and register DPM commands for all OS.(DCSG00033459) -Storcli: ProdID Legend abbreviation missing in /c0/eall show output..(DCSG00063317) -FW sometimes allows an invalid CLI command (set personality=HBA) to be successful and sets the personality to eHBA mode.(DCSG00129542) -Fixing Coverity defects.(DCSG00044004) -Unable to create JBOD using the legacy command with latest Perccli.(DCSG00118670) -MR 7.13: Storcli: GHS is shown as revertible.(DCSG00065815) -In the presence of Locked Foreign config, "/c0/fall del" shows incorrect output..(DCSG00062615) -StorCLI - '/c0 show nolog' reported as Un-supported Command.(DCSG00071410) -Set VD policy to WB (unsupported )should return failure in JBOD personality..(DCSG00076992) -Shenandoah_MRSA: Enclosure Bay count coming Wrong in CLI.(DCSG00074731) -Shenandoah_Storcli : Legend for ID in JBOD list is missing.(DCSG00069312) -Incorrect Legend abbreviation in storcli show output.(DCSG00058874) -MR 7.13: Storcli: controller add commands are listed along with vx commands..(DCSG00065744) -Even on giving wrong 'storclif delete config' command syntax, the config is cleared successfully without any error.(DCSG00055164) -Storcli.efi shows incorrect note for unsupported commands for MR controllers.(DCSG00056335) -VMware peccli, percli64 and storcli64 bit binary loads library from storcli 32 bit's installation path.(DCSG00074600) -StorCLI - /c0/eall/sall start locate not working for second enclosure connected.(DCSG00040244) -Instance Validation Failed for "/call show dpm" and controller-dpm-schema.json.(DCSG00057194) -Command description should be modified for storclif /cx set activityforlocate=.(DCSG00069746) -MR 7.13: Storcli: bbu not described in convention details.(DCSG00066314) -Shenandoah_storCLI: Add vd command for r0 getting successful with 512KB when mazStripeSize is 1MB.(DCSG00057003) -Fixing Coverity defects, uninitialized, unused variables and memory leaks.(DCSG00052049) -Start_entry is not a command parameter in show events command.(DCSG00067937) -On OS /cx/dall split mirror command shows success when there is no drive groups.(DCSG00069690) -Update the storcli readme with for Esxi 6.x and Esxi 7.0 releases.(DCSG00055533) -Extended the abbreviation in the legends.(DCSG00069703) -Shenandoah : storcli : Energy Pack show present for MR 216i controller , where the hardware is not supported.(DCSG00053888) -"set sbr" command mentioned in detailed help but not listed in help output..(DCSG00068444) -Creation of VD for with more than 64 drives is failing with "Cannot create configuration with x drives".(DCSG00056544) -Description of compare firmware ver command does not mention as IT supported command.(DCSG00070258) -Command description should be modified for /cx set alarm command.(DCSG00069709) -MR 7.13 : RSOD is seen for storcli.efi show command when the controller is in invalid state.(DCSG00066879) -StorCLI /cx restart is not supported in UEFI environment should be mentioned in help..(DCSG00068879) -Remove deprecated command 'show adpcount' from Ubuntu folder(readme).(DCSG00058329) -Segmentation fault seen while running OCR and Patrol read in loop on ESXi7.0 OS..(DCSG00066854) -Instance Validation Failed for "/call/fall import preview" and foreign-configuration-detailed-schema.json.(DCSG00068868) -Field for CV is missing in table as well as in legend for storcli64.exe show command.(DCSG00067075) -Restrict discovery of PERC HBA through StorCLI(Static binary).(DCSG00077037) -PH14 Alpha Aero - StorCLI - Difference in output noted for /cx/px set state command.(DCSG00055119) -MR 7.13 : Enclosure Device ID is mentioned in the legend for /cx/vall show command.(DCSG00067878) -MR 7.13 : Cosmetic issue is seen in the command name of /cx /cx show memscrubpatterns ?.(DCSG00067877) -Commands displayed twice in help description..(DCSG00068441) -Storcli DPM does not use legend "Resp" in EXT output.(DCSG00060706) -Enclosure ID is not mentioned as optional in "add Vd " command.(DCSG00058867) -Port information coming as internal and Location as Blank in when all the drives are removed from UBM2 Backplane.(DCSG00071756) -DPM delete help is listed under drive delete command group.(DCSG00053537) -No mention on convention in restart command description..(DCSG00068542) -Fixing Coverity defects - Uninitialized variable, resource leaks and null referencing.(DCSG00041202) -Set the PR to run on only configured array, but it complete the PR along with un-configured area..(DCSG00067103) -Fixing Coverity issues - Resource leaks.(DCSG00054690) -Storcli throws incorrect error message for /c0 add vd each r0 when Ubad drive is present in the setup..(DCSG00069698) -Use NVRAM to save PTB information -- API changes.(DCSG00082981) -Debug logs in FreeBSD is logging timestamp in different lines.(DCSG00069730) -"/c0 show nolog" shows as "un-supported command.(DCSG00068482) -Shenandoah_Storcli : The status of PD FW update on multiple drives is not proper when parallel is not included.(DCSG00069693) -Device type of UBM backplane is displayed as expander in Valvano-32i Controller managed port(C3)..(DCSG00054275) -Shenandoah_PA2:StorCLI not branding compliant for VD creation command Failure case -IO Policy specif.(DCSG00049610) -Storcli: px is not described in convention details..(DCSG00065742) -Unmap enabled not listed for unmap enabled VDs with /cx/vall show all cli command.(DCSG00112331) -Instance Validation Failed for "storcli64.exe show" and system-schema.json.(DCSG00057156) -Not able to create R1/R10 with 1MB size and strip size is 1MB.(DCSG00058162) -Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00063626) -StorCLI not reporting default oob settings from nvdata value.(DCSG00066530) -Executing storcli commands from external path throws error.(DCSG00072117) -StorCLI: /storcli /cx add vd verbose help ,strip size 512 is missing in help description under strip sizes..(DCSG00146343) -MR 7.13: Storcli: Caution mentioned instead of note..(DCSG00066554) -perccli is Reporting incorrect scheduled BBU Learn Date.(DCSG00109638) -Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements.(DCSG00046460) -Storcli64.exe /c0 show freespace shows unnecessary data when freespace is not present.(DCSG00055686) -Schema mapping list is not updated with DPM commands.(DCSG00057823) -Foreign DHS drive state is displayed as UGood under /c1/fall show all tab..(DCSG00068427) -MR 7.13: Storcli: logfile is not described in show dpmstat command..(DCSG00065838) -Statistics is spelled as Statitics in dpm stat commands.(DCSG00057112) -Cache Vault should be placed instead of battery for "storcli /cx/cv show status ?" help.(DCSG00143868) -Exit code showing "0" for failed storCLI command due to syntax error.(DCSG00054313) -Removal of log type from storcli logs.(DCSG00046794) -Discription for the term "NoVDs" is missing in the legends.(DCSG00068592) -start dpm returned error.(DCSG00035436) -Storcli: Show latest events output print shows 0.00 for all the number of events dumped (expected is the number of events queried for).(DCSG00068877) -Incorrect message noted when Ventura firmware flashed on Aero board.(DCSG00046031) -No consistency in the help details of "/c0/ex download" commands.(DCSG00064745) -Storcli license file is not present in the Vmware, Ubuntu & EFI folders.(DCSG00056538) -Storcli issuing 'add vd r0 drives=all' causes storcli to crash.(DCSG00053963) -No syntax error for multiple usage of "nolog" parameter in the command..(DCSG00066729) -Re-Host information is blank when ASO is not enabled.(DCSG00072628) -SSD Wear guage Parameter "SSD Percent used" to be removed from CLI.(DCSG00074791) -MR 7.13: Storcli: sx not described in convention details..(DCSG00066310) -Error message is improper for invalid raid level in volume creation.(DCSG00081057 (Port Of Defect DCSG00083789)) -Set MFG command does not throw an error when executed with empty file..(DCSG00074178 (Port Of Defect DCSG00074209)) -VD delete command works with multiple force options.(DCSG00165527 (Port Of Defect DCSG00167329)) -Syntax error for /c0 show AliLog ?.(DCSG00109790 (Port Of Defect DCSG00112470)) -storcli faults when issue drive poh command on Linux.(DCSG00075870 (Port Of Defect DCSG00075875)) -show memscrubpatterns shows status as success but failed in the description.(DCSG00077082 (Port Of Defect DCSG00103214)) -PH15 PA StorCLI - Segmentation fault observed when Sea IT PSOC image flashed on Ventura.(DCSG00075626 (Port Of Defect DCSG00212680)) -Wrong enclosure details are displayed when slot details are queried..(DCSG00127133 (Port Of Defect DCSG00139981)) -Storcli_VMWare gives failure messages when user tries to set the lanespeed.(DCSG00167210 (Port Of Defect DCSG00167280)) -"Download cpld" command displays incorrect output for MR controller..(DCSG00075734 (Port Of Defect DCSG00075863)) -The properties displayed in the command show htbparams has misspelled fields.(DCSG00104056 (Port Of Defect DCSG00105681)) -Instance Validation Failed for "/call/fall show" and foreign-configuration-schema.json.(DCSG00076415 (Port Of Defect DCSG00078173)) -storclif.exe /cx set copyback ? shows incorrect command name..(DCSG00075718 (Port Of Defect DCSG00075890)) -No description mentioned for "/cx set eghs" command..(DCSG00074290 (Port Of Defect DCSG00074768)) -Unified StorCLI Phase 15: storcli64 /cx add vd each help file missing options and format inconsistencies.(DCSG00139659 (Port Of Defect DCSG00139995)) -Aero Controller DPM does not report Max Response Time under 1 ms..(DCSG00099365 (Port Of Defect DCSG00102548)) -Storcli: Wrcache is mentioned instead of WT| WB.(DCSG00074284 (Port Of Defect DCSG00074767)) -Storclif allows to set Set SubOEMID as 1000 and more.(DCSG00079932 (Port Of Defect DCSG00080836)) -Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00031711 (Port Of Defect DCSG00063602)) -Storcli /cx show cc , does not shows the "Unit" for CC execution Delay..(DCSG00126229 (Port Of Defect DCSG00129753)) -storcli64.exe /c0/e1/s1 start sanitize throws syntax error..(DCSG00129738 (Port Of Defect DCSG00129750)) -forcehcb is executed with incorrect description in OS level..(DCSG00080961 (Port Of Defect DCSG00083295)) -"Show alilog" command output shows invalid PD ID in Virtual drive info..(DCSG00167354 (Port Of Defect DCSG00167449) -force is not defined under OPTIONS in storcli64 secureerase help file.(DCSG00148255 (Port Of Defect DCSG00150480)) -Storcli displays "Returned SCSI status for the command : Check condition" along with regular command.(DCSG00138580 (Port Of Defect DCSG00139200) -Aero Alpha: Storcli stops functioning during run of attached script.(DCSG00034379 (Port Of Defect DCSG00039682) -/vx is mentioned in the convention for storclif64.exe /cx set cc detailed ?.(DCSG00075700 (Port Of Defect DCSG00075894)) -DCSG00096587.(DCSG00104055 (Port Of Defect DCSG00108742)) -Avenger: ./storcli2 /c0 show ds all command(not present) shows the output of /c0 show all.(DCSG00061163 (Port Of Defect DCSG00080485) -PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup.(DCSG00050891 (Port Of Defect DCSG00079275)) -Storcli output starts with "GetCtrlInfo : ProcessLibCommand failed; retCode = 0xFF" for all command.(DCSG00214170 (Port Of Defect DCSG00214248)) -"OS Drive Name" does not display the details in "vall show all" for esxi OS.(DCSG00102559 (Port Of Defect DCSG00103190)) -Storcli: "show bbmt" displays output for an invalid VD..(DCSG00228667 (Port Of Defect DCSG00230346)) -Storcli command description shows none for Download firmware failure.(DCSG00221431 (Port Of Defect DCSG00223281)) -Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json.(DCSG00132488 (Port Of Defect DCSG00137828)) -NoVDs is displayed in dall show output..(DCSG00074628 (Port Of Defect DCSG00074763)) -"reset errorcounters" command mentions options under conventions.(DCSG00074288 (Port Of Defect DCSG00074764)) -PH16 PA - StorCLI - Compare fwprodid help page needs to be updated.(DCSG00167732 (Port Of Defect DCSG00215133)) -Display basic secure boot details for Sea IT controller.(DCSG00074184 (Port Of Defect DCSG00074218)) -No consistency in the description of Force option.(DCSG00074283 (Port Of Defect DCSG00074765)) -Storcli /c0/eall show status extended command fails to generate any output for ARM server backpla.(DCSG00146359 (Port Of Defect DCSG00150479)) -Debug log configuration file for perccli is taking storcliconf.ini.(DCSG00074691 (Port Of Defect DCSG00074757)) -Compare fwprodid command fails for 9500-16i.(DCSG00092943 (Port Of Defect DCSG00115266)) -Handling of controller properties related to drive FW download.(DCSG00138192 (Port Of Defect DCSG00139266)) -In command storcli /cx/ex/sx show DPM type=Ext , Sectors Read (Written) is not displayed correctly.(DCSG00083167 (Port Of Defect DCSG00103210)) -Ph16 PA: Storcli crash observed while running show all with NVMe drives connected.(DCSG00150686 (Port Of Defect DCSG00167881)) -Description for "profileid= " is missing in help and detailed help.(DCSG00152251 (Port Of Defect DCSG00152935)) -EKMS Boot Agent Status is not updating properly..(DCSG00049004 (Port Of Defect DCSG00050289)) -MR 7.15: Storcli: Force option is mentioned as "For".(DCSG00223195 (Port Of Defect DCSG00225259)) -Storcli displays 255 max spin-up drive count in help description instead of 240.(DCSG00098081 (Port Of Defect DCSG00108741)) -"Compare factorysettings" command displays incorrect output for wrong input file.(DCSG00075762 (Port Of Defect DCSG00075888)) -Storcli64 /cx show spinupdrivecount help file description needs update.(DCSG00150052 (Port Of Defect DCSG00150459) -Segmentation with controller show summary command when controller is in unsupported state.(DCSG00215109 (Port Of Defect DCSG00215118)) -StorCLI show autoconfig does not display all properties it can set.(DCSG00071834 (Port Of Defect DCSG00080859)) -Storcli returns wrong Operating system in Windows..(DCSG00037088 (Port Of Defect DCSG00037336)) -No description for "set autoconfig=R0 immediate" command..(DCSG00129610 (Port Of Defect DCSG00129762)) -Displaying connected portnumber as per API supportMoreThan16Phys.(DCSG00104331 (Port Of Defect DCSG00108740)) -Compare Factory command execution fails in storclif.(DCSG00074182 (Port Of Defect DCSG00074207)) EnhancementRequests: -HPE : Windows and Linux StorCLI signing.(DCSG00053511) -Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG..(DCSG00105430) -API change to support ISE completion status.(DCSG00065881) -MR API: Change event class for SPDM events.(DCSG00134416) -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI.(DCSG00222915) -Perccli: Need a mechanism to get supported device protocols for each controller form factor.(DCSG00117742) -support for sanitize command.(DCSG00108999) -Shenandoah: Support for the New Energy Pack states.(DCSG00043240) -Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713) -Remove Help Text for lanespeed commands.(DCSG00099939) -Shenandoah: Change the CLI installation Directory name from Megaraid to hpe.(DCSG00053988) -Porting storcli source from V8 Clearcase to CC9 GCP database.(DCSG00013486) -Creating VD with 0 MB or GB should not be allowed to succeed --ve case boundary value scenario.(DCSG00048859) -MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534) -DCSG00129388 -Support to display drive connector name information for SAS3.5 IT Controllers.(DCSG00120994) -Add segment area into pci information of Megaraid controller in storcli.(DCSG00032694) -Populate secureboot properties "KeyUpdatePending" and "Remaining Secure Boot Key slots" in StorCLI.(DCSG00101684) -Remove (hide) PCIe Link form in HII and from CLI for Perc11.(DCSG00077856) -Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066) -Signing Linux executables via GPG method in HSM.(DCSG00077215) -Shenandoah: Creating VD with 0 MB or GB should not be allowed to succeed - Part 2.(DCSG00053587) -Shenandoah: SSD Wear Gauage.(DCSG00046064) -MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355) -Add /px linkspeed back to help text.(DCSG00126913) -HSW Applications to not send close DCMD as the first command to perform Firmware update.(DCSG00055146) -Update/remove Snapdump save count field in show snapdump command based on FW support.(DCSG00038800) -Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780) -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058) -Add new security events.(DCSG00167313) -Request for DPMstat support in MegaRAID SAS 3.5 controllers in storcli.(DCSG00032273) -MR API: update field in event structure..(DCSG00093331) -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286) -SMART Polling Improvement- API Changes.(DCSG00214352) -References to MR_ENCL_LIST and MR_ENCL_LIST_EXT should be based on the support bit.(DCSG00037323) -Shenandoah: Type 2 Back plane Support for StorCLI.(DCSG00054795) -StorCLI: Implementing span depth logic and pd per array count for RAID 10.(DCSG00049781) -Updating BST scripts to support auto BST through VBAS in clear case version 9.(DCSG00050763) -FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event.(DCSG00086780) -Revert the CLI Help Text for backwards compatibility to include Dimmer Switch 3.(DCSG00068659) -Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10.(DCSG00073393) -New MFI Stat for the updated recon behavior.(DCSG00229416) -Shenandoah: Remove Span setting for RAID 1 & 10.(DCSG00043198) -Restore Factory Default doesn't prompt user to reboot the system after being performed.(DCSG00122000) -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security.(DCSG00106380) -Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847) -Phase 14 : StorCLI should provide power cycle message post erase all command is executed.(DCSG00039542) -Enhancement of Enclosure MultiPath algorithm in storcli.(DCSG00075191 (Port Of EnhancementRequest DCSG00079538)) -Support to generate storcli static library.(DCSG00075265 (Port Of EnhancementRequest DCSG00075687) -Updating toolchain for VMware7.0 GA.(DCSG00134764 (Port Of EnhancementRequest DCSG00136269)) 007.1212.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.12 Defects: StorCLI should refer to MR_PD_INFO.properties.ISECapable to display "Cryptographic Erase Capable" field - Revert of SCG(DCSG00014660) Making the Predictivefaliure check OEM specific in controller health algorithm(DCSG00014971) HBA345_Dev_UT: Enclosure position value in perccli is same for both front and rear BP's(DCSG00033180 Cisco - CSCVr89052 - PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup(DCSG00050891) StorCLI Point release RO DCSG00079546 - Windows binaries are missing from the RO(DCSG00081022) StorCLI 7.10 point release - /cx erase help not listing all supported commands(DCSG00081294) StorCLI 7.10 point release - Update license files to RO DCSG00079546(DCSG00081298) Removal of unsupported phy commands on IT3 controller(DCSG00025416) Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(DCSG00015875) MR_6.14_Huawei: OnDemand Snapdump in Windows gives failure message "RTTdump Feature not supported"(DCSG00020717) help is not proper for show events and set copyback commands(DCSG00005503) MR 7.12: Storcli: Instance Validation Failed for "/call show all" and controller-detailed-properties-schema(DCSG00006331) MR 7.12: Storcli: Instance Validation Failed for "/call/pall show all" and controller-phyerrorcounters-schema(DCSG00006853) Orion PA9 : Convention comes in same line while performing help for /c0/e0/s0 download.(DCSG00008084) MR_7.12_Storcli: Xenserver8: "Core dumped" while executing "/call/eall show all" and "/call/eall/sall show all"(DCSG00009400) Aero DBU PA7 : Init is in progress error message is thrown by Storcli for start migrate command when VD erase is in pro(DCSG00012344) Orion PA9 : Storcli version mismatch as compared in storcli -v and storcli properties(DCSG00014485) Orion PA9 : Storcli crashes while performing storcli /c0 show(DCSG00014486) Storcli show all cmd displaying "AVAGO" in scheduled tasks info(DCSG00014580) Aero DBU PA7 : Storcli displays multiple error messages when user enters incorrect device ID during migrate operation.(DCSG00014644) Fixing Coverity defects - resource leaks and null referencing(DCSG00015721) Correcting the detailed help syntax(DCSG00016268) MR7.12 StorCLI: Ouptput message Description wrong for StorCLI VD policy change from WT -WB(DCSG00016372) StorCLI: Fixing coverity defects and adding debug statement(DCSG00019683) perccli windows binary property page has storcli references(DCSG00019800) Aero DBU Alpha : Storcli displays incorrect error message for "add vd each r0" command when SED drive is connected in t(DCSG00019816) Application Exit code is always success for UEFI StorCLI(DCSG00020670) MR 7.12 LSA "instant secure erase" is not found in storcli as cli use secureerase(DCSG00022096) Help content for Drive Init is not showing it as Clear operation(DCSG00022893) MR7.12_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(DCSG00022942) MR 7.12: Storcli: Instance Validation Failed for "/call start Diag Duration=40" and controller-diag-schema(DCSG00023543) MR 7.12: Storcli: Instance Validation Failed for "/call show linkconfig " and controller-linkconfig-schema(DCSG00023545) Aero Alpha : Storcli throw Segmentation Fault in Driver load error handing path -(DCSG00024554) MR 7.12_Storcli: On ARM server the latest storcli Vendor,Licenses,URL and distribution shows as "AVAGO Technologies"(DCSG00025885) Aero DBU Alpha - Scheduling is displayed as Schedulling under "/cx set pr ? " command description(DCSG00027203) Add warning/recommendation messages for changing lane speeds(DCSG00027869) Orion MR : Description for storcli output is not proper after collecting the snapdump with id=all(DCSG00031711) Aero Alpha: Storcli stops functioning during run of attached script(DCSG00034379) Storcli returns wrong Operating system in Windows.(DCSG00037088) MR 7.12_Storcli: The latest storcli vmware build reference URL shows "http://www.lsi.com"(DCSG00039104) MR 7.12_Storcli: The latest storcli vmware build 007.1209.0000.0000 shows older package version(DCSG00039112) PERC 11:EKMS:PKG 2973: EKMS Boot Agent Status is not updating properly.(DCSG00049004) PH13 StorCLI PA - Update help section about 'nolog' option(DCSG00002975) PH13 PA - StorCLI - Incorrect message for /call/pall show all command(DCSG00003003) StorCLI_7.12_Ph13:Phyreset Fails on IT controllers(DCSG00005488) PH13 PA - StorCLI - NVMe drive linkspeed not seen with /cx/pall show(DCSG00009522) With IT controller for set or reset with invalid phy is not showing error(DCSG00010226) Aero_storecli:Using latest storecli Firmware product id parameter value fail to display.(DCSG00011446) MR_7.12: Storcli: Segmentation Fault for "storcli64 page"(DCSG00012563) Storcli ph13: Fixing array size for function DEBUG_LOG(DCSG00014665) Aero Orion IT:- Mismatched phy info listed for 440-16e/440-16i(DCSG00023320) Enclosure position value in storcli is same for both front and rear BP's(DCSG00031302) Misleading error message when create unmap VD with storcli64.exe /c0 add vd each r0 unmap using unmap and non-unmap PDs(SCGCQ02059720) StorCLI: Debug prints enabled in latest Phase 12 PA storCLI.efi image(SCGCQ02097317) Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101372) MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json(SCGCQ02112192) DBU Aero PA4 : Cosmetic error is seen in command description for Show SSDThermalPollInterval ?(SCGCQ02124673) Aero A0 PA4: "Storcli /c# set jbod=on" shows success but does nothing(SCGCQ02117219) Aero (DBU PA4):Storcli: Junk character in PD start locate command description.(SCGCQ02125654) Phyreset Fails on IT controllers and update help(SCGCQ02169242) Drive mode-e fw download with activatenow is not working(SCGCQ02142068) MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02150924) MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02165933) Phase 12 - Oct Huawei DET - "./storcli64 /c0/pall show" Command Fails With "Null pointer exception"(SCGCQ02175414) Phase 16 (IR) - Oct Huawei DET - Unsupported Drive State is Displayed for "./storcli /c0 show" Command(SCGCQ02170389) MR 7.11 - Oct Huawei DET - Nomenclature Issue for "rbld=Rebuild" In Storcli Show Help Menu for SAS3516(SCGCQ02170197) Usage of 64 bit address instead of 32bit address while sending commands to FW in uEFI driver less environment(SCGCQ02174934) MR_7.10_Storcli: Storcli displays incorrect error message for unmap VD creation with regular HDD drives.(SCGCQ02019751) PH12 PA - StorCLI crashes when call/pall show executed with SAS3 & Ventura boards(SCGCQ02103217) PH12 PA - StorCLI - Debug StorCLI binary is placed in both places of EFI dir RO SCGCQ02085693(SCGCQ02091140) PH12 PA - Update readme file in VMwareOP64 folder in accordance with PR SCGCQ01923533(SCGCQ02108550) MR 7.11: Storcli.efi: In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02115036) Aero (DBU PA4):Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) Aero DBU PA4 : storclif /cx show configautobalance ? help output shows the name as "show NCQ"(SCGCQ02124632) Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02136333) Aero (DBU PA5):Storcli: Storcli: "/c0 set patrolread ?" lists detailed help and snapdump rttdump is mentioned as optional.(SCGCQ02140873) MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02150921) Aero (DBU PA5):Storcli: Force is not mentioned as key word in "/cx/vx del" error message.(SCGCQ02142017) MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(SCGCQ02165944) Aero (DBU PA5):Storcli: "Ctrl" legend not mentioned.(SCGCQ02146822) MR7.11_Storcli: storcli set securitykey detailed help does not show description for all the options(SCGCQ02096732) MR7.11_Storcli: storcli show output shows UBUnsp as UBad Unsupported where as UGUnsp just Unsupported(SCGCQ02096722) Aero IT - PA3 - StorCLI crashes for 'storcli J command(SCGCQ02117749) Lenovo Orion IT:- Command to flash UEFI on Aero/sea HBA from storcli/scrutiny fails(SCGCQ02137751) Flashing of Completeflash fails on Sea IT controller(SCGCQ02139780) StorCLI: Fixing coverity defects(SCGCQ02123769) MR 7.11: Storcli: Instance Validation Failed for /call/show_smartpollinterval.json and controller-smartpollinterval-schema.js(SCGCQ02135516) DBU PA5 Aero : Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02132024) Aero (DBU PA5):Storcli: No "Rbld" legend during rebuild.M(SCGCQ02146819) complete Lane WWID is not displayed(SCGCQ02145716) Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176681) Adding missing syntax for the command deviceorderbyfirmware(SCGCQ02121705) MR 7.11: Storcli: Instance Validation Failed for "/call/vall show unmap" and vd-unmap-schema.json.(SCGCQ02113316) Aero (DBU PA5):Storcli: "completeflash" is listed in Windows help file.(SCGCQ02141931) Aero (DBU PA5):Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02140878) Force option is needed only for Parallel Drive microcode update, but it allows to take for normal also(SCGCQ02177086) StorCLI Copyright Notice Needs to be updated(SCGCQ02174040) Wrong error message when create unmap VD with unmap disable on controller(SCGCQ02064118) Aero DBU PA4 : storclif /cx delete colinfo ? shows syntax error(SCGCQ02124492) MR 7.11: Storcli: Instance Validation Failed for "/call show" and controller-properties-schema.json.(SCGCQ02108770) PH12 PA - StorCLI version not getting printed for show file command(SCGCQ02105185) Aero DBU PA4 : Command name shown in help output differs for storclif.efi /cx show limitmaxrateSATA ?(SCGCQ02124667) Aero DBU PA4 : Redundant information is displayed for set driveactivityled command in storclif.(SCGCQ02124675) Aero (DBU PA4):Storcli: Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) Aero DBU PA4 : storclif.efi /cx show deviceorderbyfirmware ? throws syntax error.(SCGCQ02124528) MR 7.11: Storcli: Instance Validation Failed for /call/show_consistencycheck.json and controller-cc-schema.json(SCGCQ02135510) Phase12-Storcli- In Windows storcli64.exe /c0 show htbparams is showing random values for SAS3 controller(SCGCQ02125598) Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02140859) PH12 BETA - /cx erase help not listing all commands(SCGCQ02146466) Aero (DBU PA5):Storcli: No consistency in the usage of "|" in the command such as "on|off".(SCGCQ02142022) Phase 12 - Oct Huawei DET - Delay Option In PD Download Operation is Not Honored(SCGCQ02176690) With IT controller for set or reset with invalid phy is not showing error(SCGCQ02181823) Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02184862) Drives connected to active backplanes not showing the phy info in connector name(SCGCQ02112424) PH12 PA - StorCLI - 9310-8i IR FW download fails(SCGCQ02121783) MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02114898) Aero PA6 - storcli snapdump id=x errors without optional file parameter(SCGCQ02161748) PH11 - StorCLI - Incorrect message for /call/pall show all command(SCGCQ02169536) cli does not allow to do crypto erase on SATA SSD.(SCGCQ02147075) MR7.11_Storcli: Storcli stop erase needs an help file update(SCGCQ02168895) Phase 12 - Oct Huawei DET - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180495) Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(SCGCQ02191421) Aero PA4 DBU : Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02123789) Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) Aero (DBU PA4):Storcli: /c0 compare lists /c0/px compare command.(SCGCQ02124246) StorCLI: Fixing coverity issue in libmod(SCGCQ02123790) SWR:Storcli: "Show" and "show all" output Description is shown as "No Enclosures found"(SCGCQ02146814) MR 7.11 storcli -help missing the verbose option(SCGCQ02158600) Phase 12 - Oct Huawei DET - PD FW Download is failing for Mode f(SCGCQ02168197) PH12 PA - StorCLI - Incorrect string displayed with show command in FreeBSD 11.2(SCGCQ02094529) PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02119004) MR 7.11: Storcli: Instance Validation Failed for "/call/v5 set bootdrive=off" andcontroller-bootdrive-schema.json.(SCGCQ02115786) StorCLI: Fixing coverity defects for second run(SCGCQ02125523) MR 7.11: Storcli: Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02135526) Aero (DBU PA5):Storcli: /c0 set ? lists bbu,mx,px and lnx commands.(SCGCQ02136689) Aero DBU PA4 : Storclif should not display vendor name in storclif.efi /cx/ex download help command(SCGCQ02123765) Aero (DBU PA5):Storcli: Improper spacing for the linkspeed description and "YY" parameter leads to confusion.(SCGCQ02139910) MR 7.11: Storcli: Instance Validation Failed for /call/show.json and controller-properties-schema.json(SCGCQ02135420) MR 6.14 - Oct Huawei DET - "Rbld=Rebuild" is Not Available In Storcli Show Help Menu for SAS3108(SCGCQ02170181) MR 7.11: Storcli: Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02150651) Aero (DBU PA5):Storcli: Help notes needs an update.(SCGCQ02146823) Phase 12 - Oct Huawei DET - Incorrect Status for PD FW Download (Ventura IT)(SCGCQ02173203) Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02174296) Enchancement: To bring MR 7.10 storcli change to CC9 GCP database(DCSG00013486) Support to generate storcli static library(DCSG00075265) Bring MR 7.11 storcli change to CC9 GCP database(DCSG00014492) Updating the Makefile and projects as per new CC/CQ changes(DCSG00003002) Updating the Json Schema files with respect to the latest code(DCSG00007394) Controller commands Json Schema files update as per the latest code(DCSG00007435) Schema validation : Schema update for VD/DG/Foreign related commands(DCSG00007453) Add UEFI Shell StorCLI support for 64-bit Ventura Gen MR Legacy Boot solutions (solutions without UEFI driver)(DCSG00008200) Changing the CBB download image type as per new MR API(DCSG00010253) Migrating StorCLI's 64 bit VMware toolchain to 6.8.7-13394445(DCSG00014503) PERC 11: Provide ability to expose SEP to host and disable PERC SES management in PercCLI / HII(DCSG00015020) Supporting build and BST process through VBAS in Clear Case version 9(DCSG00024818) Windows and Linux StorCLI HSM based signing support(DCSG00031618) StorCLI PH13: Adding interface for lane display and configuration command for IT controllers.(DCSG00007909) Atlas Support on Aero-IT(DCSG00008038) Concern for security key passed in from storcli to be read in process data(SCGCQ02066380) Support FMP Images in UEFI Version of PERCCli(SCGCQ02078649) Add segment area into pci information of Megaraid controller in Storlib and storcli(SCGCQ02201178) Create DVT / PVT PnP IDs for Cisco Pismo Beach card(SCGCQ02108965) Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066395) Enable SnapDump for iMR(SCGCQ02208421) HDET: Support in storCLI support PD firmware download for 3008IR/3008IT controllers(SCGCQ02160016) multi VSES implementation(SCGCQ02066438) Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066399) Add displaying list of enclosures in controller show and show all command(SCGCQ02124566) LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02085102) SAS 3_5 Ventura family UEFI NVMe drive serial number issue(SCGCQ02074657) Unmap error message changes as per new description in MR API(SCGCQ02115017) MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02066386) Lenovo Whitley/Orion - Addendum 7 - Lenovo request to support StorCLI & LSA for Valvano 28i (MR+Cub) and Custom Form Factor(SCGCQ02082612) 007.1022.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects : - PERCcli Help text is missing description for "Lane Information"(SCGCQ02150899) - Add NVMe width comments to mr.h(SCGCQ02146846) - Fix API changes done for NVMe readiness(SCGCQ02142981) - CLI returns "success" when attempting to set DS3 or DS4 to enabled(SCGCQ02116380) - CLI returns "success" when attempting to change the H840 controler to eHBA personality.(SCGCQ02114332) - CLI returns wrong error code upon failure(SCGCQ02084966) - HPE shenandoah: storcli crashes during show command when DGs present(SCGCQ02065695) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02045324) - ROP version not displayed with latest ROP version SCGCQ02035462(SCGCQ02041094) - FW flash fails to load the latest image after upgrade downgrade with resetnow option(SCGCQ02035152) - retentiontest command is successfully triggering BBU test on Shenandoah controller(SCGCQ02021398) - Storclio (007.0911.0000.0000) detailed help file doesn't have " locale " option for flashing FW in Dual/Active & Backup mode.(SCGCQ02012025) - hot spare reference in Add Spare command output(SCGCQ01897463) - Shenandoah:Strocli show all output return failure but generates output(SCGCQ01929191) - Junk message "STR_JBOD_OBJ" is displayed in the output of storcli /c0 show JBOD command.(SCGCQ01932770) - Shenandoah_StorCLI: No legend presend for VD Delete Failure(SCGCQ01936811) - Shenandoah_StorCLI:Setting Unmap=OFF gives success for a LD when unmap is not supported and not enabled on that LD(SCGCQ01940291) - Set WrCache= WB ,says success even though VD is in WT.Proper warning message should be given to the user(SCGCQ01940296) - Legend missing for LD BGI resume/pause commands(SCGCQ01940347) - System hangs while creating VD in EFI shell.(SCGCQ01945551) - Shenandoah_StorCLI: Storcli crashes on checking LD preserved cache info(SCGCQ01955069) - CLI is showing the incorrect OS version(SCGCQ01956276) - Unified StorCLI : Add extra space to CBB header(SCGCQ01956678) - PH10 Alpha - StorCLI throws "0 Failed 32782 Failed to get PD Info" when /c0 show executed in EFI(SCGCQ01960322) - JBOD list is not showing in order when using /cx show(SCGCQ01961527) - supported personalities has blank value(SCGCQ01965370) - storcli faults for enclosure show command(SCGCQ01985815) - MR7.10_PA1: Storcli binaries for RHEL/SLES OS is not present for ARM(SCGCQ02006374) - NVMe drive displays incorrect information with IT card(SCGCQ02009852) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02016762) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for snapdump commands.(SCGCQ02018073) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02018134) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02018135) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02018140) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02018333) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02019740) - Instance Validation Failed between " controller-lane-show-schema.json" and "/call/lnall show"(SCGCQ02019746) - Pending Image details are not populated after FW upgrade and downgrade.(SCGCQ02024065) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all "(SCGCQ02032911) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02034493) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02035370) - remove the maxconcurrentpd check from storcli and report fw returned failure(SCGCQ02053910) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02061340) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show_all"(SCGCQ02062957) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02064836) - Storcli: "show config" command shown as Un-supported.(SCGCQ02064839) - PH11 Alpha - StorCLI 'show file' command throws segmentation fault for complete flash image in FreeBSD(SCGCQ02065691) - Storcli: No schema files for htbparams commands.(SCGCQ02065698) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02065734) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02067575) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02069817) - Typo in storcli /c0 set linkspeed help(SCGCQ02070951) - Aero (DBU PA2): Storcli: No syntax error displayed for "storcli mronly" command.(SCGCQ02072746) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02076923) - Empty data is listed when we query for show linkconfig(SCGCQ02076931) - htbparams help output needs update.(SCGCQ02077156) - show/set lane speed shows success when we are in SAS profile(SCGCQ02078437) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02078513) - Recon command (./storcli /cx set recon) is throwing syntax error.(SCGCQ02081415) - storcli /c0/ex/s23,24 show patrol read doesnt not show error for slot 24 (Invalid Slot)(SCGCQ02082142) - Aero (DBU PA2): Storcli show detailed help does not list "show all " command.(SCGCQ02082303) - Aero (DBU PA2): Storcli: Get rttdump detailed help shows syntax error.(SCGCQ02082460) - Storcli: Incorrect message while executing "storcli64.exe /c0/v0 del discardcache"(SCGCQ02083828) - Failure status for /call/sall and /call/eall/sall command.(SCGCQ02084549) - Storcli: Error in /c0/f0 command output.(SCGCQ02089892) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02090770) - Storcli doesn't exit with controller status message after doing OFU.(SCGCQ02091548) - Libmod changes for SCGCQ02090770 (SCGCQ02096774) - Aero (DBU PA3): Storcli: FW hits Megamon while executing storcli in EFI shell when EFI Driver is unloaded.(SCGCQ02097647) - StorCLI crashes for 'storcli J command(SCGCQ02117749) - Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) - Controller Health Status not consisten across applications(SCGCQ02182243) - Perccli does not enable Power Save mode for UG & HS type 1 & type 2. (SCGCQ02125408) - StorCLI: Delete config failure message need correction(SCGCQ02086726) - StorCLI:VD reference in Delete preserved cahce command output -Branding(SCGCQ02083992) - VD reference in set JBOD command output message(SCGCQ02078507) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02075242) - STORCLI: Show command output having wrong legend for Slt for oem Hercules(SCGCQ02067616) - Grammatical error in Perccli message(SCGCQ02065513) - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02045967) - VD legend missing in the legend for Foreign config show all output(SCGCQ02016798) - Hercules:Shenandoah:Transformation is coming as Reconstruction , while migrating the Raid 1 to Raid 5 .(SCGCQ01897468) - Mis-spelled words in StorCli's Help(SCGCQ01898853) - Hot spare reference in storcli.exe /cx/ex/sx show all command output(SCGCQ01905019) - Reference to VD in storcli.exe /c1/jbodall delete command output(SCGCQ01905077) - Fixing coverity issues Removing dead code and Out of bound access(SCGCQ01924504) - Shenandoah_StorCLI: HotSpare reference in Add VD Command output(SCGCQ01936887) - storcli /c0 show events output not listing the Event ID's(SCGCQ01940290) - Shenandoah_StorCLI:Hot spare reference in storcli64 /cx show/set restorehotspare command outputs(SCGCQ01940437) - Shenandoah_StorcLI:Drive Group reference in Add dedicated spared drive command in CLI(SCGCQ01955167) - Intel NVMe drive "Model Number" displayed incorrect under Device Attributes(SCGCQ01957949) - Aero: Segmentation Fault in storcli /c0 show all(SCGCQ01996444) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02006450) - storcli gives error when the lane configuration is set as X8 (SCGCQ02007152) - MR_7.10_Storcli: No schema file for controller unmap commands(SCGCQ02016749) - MR_7.10_Storcli: Instance Validation Failed "controller-restorehotspareoninsertion-schema" and "set restorehotspare"(SCGCQ02016765) - MR_7.10_Storcli: Instance Validation Failed "controller-properties-schema" and "/c0 show"(SCGCQ02016768) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02016771) - MR_7.10_Storcli: Instance Validation Failed between "controller-autoconfig-schema.json" and "show autoconfig" JSON output.(SCGCQ02018227) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02018277) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02018305) - MR_7.10_Storcli: Instance Validation Failed between "system-schema.json" and "./storcli show" and "show all" JSON output.(SCGCQ02018313) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02018327) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02019729) - Storcli displays drive state as UBad instead of UBad (unsupported)(SCGCQ02031615) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02040779) - Fixing coverity issues Fixing resource leaks(SCGCQ02043601) - Storcli help file should show the expand size format.(SCGCQ02047109) - Updating the storcli schema mapping document (SCGCQ02050586) - PH11 Alpha - StorCLI - Parse error observed for command 'StorCLI J' while validating Jason(SCGCQ02053030) - JSON-SCHEMA : IT-Controller Json-schema validation erros in MR_SAS_Unified_StorCLI_7.10(SCGCQ02053914) - Aero: Storcli : Storcli crashed when Firmware upgrade tried on Sea controller(SCGCQ02060276) - Aero (DBU PA2): Storcli: JSON readme file does not have complete VD and PD support list.(SCGCQ02061328) - Instance Validation Failed bw "enclosure-drive-detailed-schema.json" & "/call/eall/sall show all"(SCGCQ02062958) - PH11 Alpha - StorCLI - Compare linkspeed command failed for 6Gbps link(SCGCQ02063932) - Invalid aero controllers are not displayed with apt message in driver less mode(SCGCQ02065581) - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02072448) - Aero (DBU PA2): Storcli: /cx/mx command does not mention about "Auto" settings.(SCGCQ02082208) - Storcli: Force is mentioned as optional in snapdump delete command. (SCGCQ02083822) - Help of /cx/px compare command needs update and /cx/px reset ? shows syntax error.(SCGCQ02084752) - No proper legends in /fall output.(SCGCQ02100491) - Aero (DBU PA3): Storcli: Incorrect schema mapping for "/cx set autoconfig " command.(SCGCQ02101558) - Storcli: OCR helps needs update.(SCGCQ02113241) - Storcli: No proper description of set and show sesmultipathcfg.(SCGCQ02113358) - StorCLI: File sync issue with rel and dev stream for MR 7.10 (SCGCQ02116806) - Storcli script stops with error "can't fork: Cannot allocate memory" (SCGCQ02184427) - IT- CLI treats EID and Partner Device ID as two different enclosure during pd info command and fails.(SCGCQ02185442) - "/eall show" will not show enclosure details if it is in multitpath & no drives connected.(SCGCQ02186022) - Legacy messages present with create and rekey of securitykey on controller(SCGCQ01581843) - Shenandoah_StorCLI:VD reference in CLI outout for Firmware update command failure case(SCGCQ02083991) - StorCLI: VD listing for c0 show and vall show is toggled (SCGCQ02078936) - output information for link configuration is displayed incorrectly(SCGCQ02073046) - Drive Groups is shown instead of arrays in show all command(SCGCQ02048660) - Help is not updated for get snapdump without ID option.(SCGCQ02046991) - StorcliO show oob command fails for Invader based cards(SCGCQ02040783) - Adding debug logs to Mfi files(SCGCQ01891583) - MR7.8_Storcli: Storcli fails to install on ARM server with Missing Maintainer message(SCGCQ01919830) - StorCLI show SAS address for NVMe drives (SCGCQ01921258) - Unified StorCLI 7.9 : Fixing coverity issues - Dead code,resource leaks,and memory corruption - Part 1(SCGCQ01925503) - Incorrect help option for set autoconfig in StorCli's Help(SCGCQ01932035) - Unmap enabled property is shown in VD detailed properties when controller does not support unmap (SCGCQ01932177) - Unified StorCLI - Aero : "FullFlashImage" environmental variable component stamp change(SCGCQ01963738) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02018137) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON output.(SCGCQ02018322) - MR_7.10_Storcli: Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show"(SCGCQ02024327) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034064) - Aero IT - PA1 - StorCLI - BIOS verion not displayed with flash file using 'show file' command(SCGCQ02034490) - failure in StorCLI enclosure show status (SCGCQ02040640) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02042106) - Incorrect status displayed for pause rebuild command.(SCGCQ02043610) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044777) - Port information is not displayed for Vses Backplane(SCGCQ02053070) - "c0 delete ?" does not list snapdump command.(SCGCQ02053639) - Incorrect status displayed for resume copyback command.(SCGCQ02062834) - Aero (DBU PA2): Storcli: Instance Validation Failed bw "vd-operations-migrate-schema.json" & "start_migrate"(SCGCQ02062960) - Aero (DBU PA2): Storcli: Result shows blank for "resume patrolread" failure case.(SCGCQ02064795) - Fail to set the linkconfig . (SCGCQ02070797) - Storcli /c2 set linkconfig conname=c0,c1 configid=14 returns invalid syntax error(SCGCQ02070953) - Aero DBU PA2 : Syntax error is seen in storcli /cx(x|all (SCGCQ02077085) - Aero (DBU PA2): Storcli: Syntax error for "/c0 download psoc/efibios/cpld/fcode ?" download commands.(SCGCQ02077175) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02078409) - Incorrect string displayed in show command in FreeBSD OS(SCGCQ02082949) - MR_7.10_Storcli: "storcli show file=filepath" command shows failure status.(SCGCQ02085630) - PCI Linkconfig configid status is failure, even though it was set(SCGCQ02086669) - Storecli_Aero: Using latest storecli show file command "Aero-DVT -HBA 9500-16e" board output version number shows wrong.(SCGCQ02089427) - Libmods changes for defect SCGCQ02062957(SCGCQ02089862) - Help update for "add vd cachevd" command as Normal VD is created with failure status.(SCGCQ02091155) - Preserved cache help file shows a mismatch in command and the convention.(SCGCQ02106218) - Aero DBU PA4 : Storcli doesn't show the convention details properly for storclio /cx/px show command(SCGCQ02113377) - Aero (DBU PA4):Storcli: Syntax error for /c0 show AliLog ?(SCGCQ02113506) - Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) - Misleading error msg "157 Failed Cannot mix unmap and non-unmap physical drives in same array"(SCGCQ02151484) - Cryptographic erase field is shown "yes" but crypto erase fails.(SCGCQ02175346) - Device Type for non-UBM backplanes are being shown as Enclosure instead of Backplane(SCGCQ02101095) - Multiple status messages are displayed in the output (SCGCQ02073042) - Controller health status is shown as optimal when megacell cable is disconnected.(SCGCQ02021393) - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"(SCGCQ01889700) - Shenandoah_StorCLI:32 Binary crashes on giving invalid input to the command storcli.exe /c0/jbod0 show(SCGCQ01905831) - For NVMe drive use the term NVMe instead of PCIe(SCGCQ01923119) - PD show all command displays SSD weargauge details , which is not required.(SCGCQ01927864) - MR_7.10_Storcli: Junk character in error message while creating SED vd with regular HDD drives.(SCGCQ02016701) - MR_7.10_Storcli: Incorrect command syntax mentioned in Schema_mapping_list.xlsx file for "/cx set autoconfig" command.(SCGCQ02018097) - Instance Validation Failed between "vd-operations-bgi-schema.json" and "/call/v1 show bgi " and "show init".(SCGCQ02035551) - Storcli shows incorrect output for delete events command(SCGCQ02045816) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02048150) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053923) - StorCLI displays expansion as successful even when there is no free space to expand(SCGCQ02057361) - Instance Validation Failed between "controller-patrolread-schema.json" and "/call resume patrolread"(SCGCQ02062942) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02063689) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02064120) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02064828) - Aero (DBU PA2): Storcli: Inconsistency in "add vd" command syntax.(SCGCQ02082196) - Details are displayed twice in "/cx/bbu start ? "(SCGCQ02100905) - Storcli: set termlog shows [=on|off] mentioned as optional.(SCGCQ02113353) - CLI is missing the JBOD PD size for SysPDs when using the "show jbod" command(SCGCQ02132277) - Percli returns “invalid arguments" when trying to create a VD using some PDs already configured in a VD and some U(SCGCQ02122169) - Topology information missing from Storcli output(SCGCQ02048612) - (SCGCQ02040597) - Unified StorCLI: StorCLI does not return the return code from SLIT/SLIR3 to explorer/command processors(SCGCQ01925156) - Virtual drive reference in Delete Preserved cache command output(SCGCQ01940333) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940805) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01948579) - Shenandoah : Firmware receives incorrect erase type for sanitize crypto erase option(SCGCQ01958564) - Storcli shows BBU present instead of EnergyPAck in HWcfg for StorCLI /cx show all output.(SCGCQ01985592) - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Sea (3816_Eval) IT Controller(SCGCQ02008219) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for errorcounters commands.(SCGCQ02018078) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02030652) - There is no error message for smart drive failure command.(SCGCQ02040645) - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02046036) - JSON Schema : Updating the schema list with Virtual drive command set(SCGCQ02057360) - storecli_Aero:In linux error message observed in the show output.(SCGCQ02057699) - Checking in JSON schemas(SCGCQ02061305) - Junck character displayed in Virtual SES phy id, when we query phyerror counter for enclosure.(SCGCQ02094970) - Aero (DBU PA3):Storcli: Help of /cx/px reset does not mention about option hard reset.(SCGCQ02100896) - BBU show detailed help does not list "show learn " command.(SCGCQ02100915) - Storcli: Instance Validation Fails for all /call/e65/sall commands where "e65 is not found".(SCGCQ02101564) - Storcli: Remove Nytro supported options in "/cx [start] flush|flushcache [cachecade | ALL]" help.(SCGCQ02113484) - MR7.10 cli return mesg. typo after ctrl restart then immediately running storcli64 /c0 show.(SCGCQ02113833) - Storcli: /c0 compare help lists /c0/px compare command.(SCGCQ02124246) - Serial number not displayed fully in 7.10 StorCLI 007.1017.0000.0000 for IT Controller(SCGCQ02173789) - Hide BBU details from the command "storcli /c0 show alilog" for HPE(SCGCQ01937259) - Disk group is displayed instead of array on HPE platforms(SCGCQ01965366) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02016758) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02024740) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02034471) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02035437) - Instance Validation Failed for "/call show and /call show all".(SCGCQ02101432) - Instance Validation Failed bw "drive-group-detailed-schema.json" and "/call/dall show all".(SCGCQ02101513) - Autoconfig options are allowed to set with latest storcli(SCGCQ02053643) - Unified StorCLI Phase 10 : Image checksum should not be performed for aero images(SCGCQ01942200) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02035439) - Fixing coverity issues Fixing resource leaks and explicit NULL dereferencings(SCGCQ02042242) - Unified StorCLI : Fixing resource leaks - Part 1(SCGCQ02042513) - Updating Schema mapping doc and fixing validation errors (SCGCQ02057434) - Storcli: Instance Validation Fails for vd-bootdrive-schema.json and vd-unmap-schema.json.(SCGCQ02101568) - Aero_storecli:Using latest storecli firmware download fail with noreset option.(SCGCQ02101570) - Aero DBU PA4 : Syntax error is seen for the command - storclio.efi /cx/px set state ?(SCGCQ02113123) - PD info incorrectly shows Number of Blocks for >TB drives(>3TB in my case(SCGCQ02183653) - CLI is returning "success" when attempting to set bios mode to Ignore Errors.(SCGCQ02121017) - On Demand SnapDump does not show proper time stamp.(SCGCQ02084833) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01892288) - Initialize the MFG structure(SCGCQ01901166) - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Aero (3916_Eval) IT Controller(SCGCQ02021194) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02040756) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02042296) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047100) - Updating storcli-cmd-list.xlsx for Drives(SCGCQ02056199) - Message with Incorrect controller object is displayed while setting SSD Caching on VD(SCGCQ02057085) - Storcli displays grammatically incorrect message in detailed help file.(SCGCQ02097641) - MR_7.10: Storcli: Property is shown as SCSI Umap instead of SCSI Unmap.(SCGCQ02101572) - Storcli: /c0 show detailed command does not list /cx/px show phyerrorcounters and /cx show vpd.(SCGCQ02113262) - Aero (DBU PA4):Storcli: Incorrect description of "/c0/v0 show migrate" command.(SCGCQ02113511) - Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) - Storcli: Junk character in PD start locate command description.(SCGCQ02125654) - Storcli doesn't exit with controller status message after doing OFU. (SCGCQ02101069 port of SCGCQ02091548) - perccli /c0 show all lists topology without any DG's present (SCGCQ02085925 port of SCGCQ01998332) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) - Libmods: HPE serial number display(SCGCQ02062634 port of SCGCQ01885657) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) - failure in StorCLI enclosure show status (SCGCQ02043616 port of SCGCQ02040640) - Expander FW download using storecli utility crashs.(SCGCQ01979616 port of SCGCQ01979599) - Hide "set pdfaileventoptions" command from CLI Help(SCGCQ01892551 port of SCGCQ01880722) - Error message when Maximum number of VDs are reached (SCGCQ01911777 port of SCGCQ01856544) - Adding CLI command to display/toggle new controller property.(SCGCQ01927583 port of SCGCQ01106982) - System hangs while creating VD in EFI shell.(SCGCQ01945574 port of SCGCQ01945551) - storclio command not working to update FW on SATA disk(SCGCQ01963953 port of SCGCQ01918814) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01963954 port of SCGCQ01937410) - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964173 port of SCGCQ01955389) - Add security-related compilation and linker flags to StorCLI - Linux (SCGCQ01966163 port of SCGCQ01892560) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations (SCGCQ01982925 port of SCGCQ01979483) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01985486 port of SCGCQ01893074) - Enable iMR advanced debug dump(SCGCQ02035300 port of SCGCQ01873124) - Drive Size Display Miss Match In Storcli Show Output (SCGCQ02074659 port of SCGCQ02072353) - HDET:Libmods-Boot device should be presented as /dev/sda in Linux operating system during installation and post installation (SCGCQ02082198 port of SCGCQ02046182) - HDET: Boot device should be presented as /dev/sda in Linux operating system during installation and post installation(SCGCQ02082199 port of SCGCQ02016712) - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02085669 port of SCGCQ02045967) - storclif /cx delete colinfo ? shows syntax error (SCGCQ02124654 port of SCGCQ02124492) - PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02128167 port of SCGCQ02119004) - Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02142248 port of SCGCQ02140878) - Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02145876 port of SCGCQ02140859) - PERCCLI to support creation of VD with WB policy for PERC8 MR(SCGCQ01892550 port of SCGCQ01891650) - MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+ (SCGCQ02139866 port of SCGCQ02066386) - Libmod changes for SCGCQ02090770(SCGCQ02097658 port of SCGCQ02090770) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) - Drive Size Display Miss Match In Storcli Show Output (SCGCQ02075280 port of SCGCQ02072353) - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) - Storcli help file doesn't show recon rate command instead it shows migrate rate. (SCGCQ02047747 port of SCGCQ02046036) - Storcli shows incorrect output for delete events command(SCGCQ02046875 port of SCGCQ02045816) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations (SCGCQ01979535 port of SCGCQ01979483) - enhance warning message for personality switch indicating interruption could cause controller to be unstable(SCGCQ01892552 port of SCGCQ01892549) - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump" (SCGCQ01906745 port of SCGCQ01889700) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01925211 port of SCGCQ01196785) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929137 port of SCGCQ01224857) - For NVMe drive use the term NVMe instead of PCIe (SCGCQ01963960 port of SCGCQ01923119) - StorCLI show SAS address for NVMe drives (SCGCQ01963964 port of SCGCQ01921258) - JBOD list is not showing in order when using /cx show(SCGCQ01965193 port of SCGCQ01961527) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965209 port of SCGCQ01949495) - supported personalities has blank value (SCGCQ01971366 port of SCGCQ01965370) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977028 port of SCGCQ01948579) - Expander FW download using storecli utility crashs.(SCGCQ01979617 port of SCGCQ01979599) - WBSup abbreviation defined twice when running perccli /cX show profile(SCGCQ01995022 port of SCGCQ01993282) - spell mistake in start diag operation failure(SCGCQ01998963 port of SCGCQ01998330) - Proper message to be given on VD creation with wb option while Battery not connected/Failed(SCGCQ02028787 port of SCGCQ01972504) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02028810 port of SCGCQ02008676) - Enable iMR advanced debug dump(SCGCQ02035289 port of SCGCQ02030908) - On Demand SnapDump does not show proper time stamp.(SCGCQ02085609 port of SCGCQ02084833) - Flashing of Completeflash fails on Sea IT controller(SCGCQ02139848 port of SCGCQ02139780) - Storcli: "Ctrl" legend not mentioned.(SCGCQ02150640 port of SCGCQ02146822) - storcli -help missing the verbose option (SCGCQ02160908 port of SCGCQ02158600) - MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02168183 port of SCGCQ02165933) - Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02179296 port of SCGCQ02174296) - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180519 port of SCGCQ02180495) - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy. (SCGCQ02047079 port of SCGCQ02024740) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) - storcli faults for enclosure show command(SCGCQ01986423 port of SCGCQ01985815) - storclio command not working to update FW on SATA disk(SCGCQ01922919 port of SCGCQ01918814) - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964153 port of SCGCQ01955389) - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01965185 port of SCGCQ01413253) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965210 port of SCGCQ01949503) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01966261 port of SCGCQ01893074) - Add security-related compilation and linker flags to StorCLI - Linux (SCGCQ01985558 port of SCGCQ01892560) - Snapdump unsupported commands for HPE needs to be disabled(SCGCQ01996375 port of SCGCQ01985589) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02009848 port of SCGCQ01992461) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02011417 port of SCGCQ01761309) - StorcliO show oob command fails for Invader based cards(SCGCQ02043788 port of SCGCQ02040783) - Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02124488 port of SCGCQ02123789) - Storcli: "completeflash" is listed in Windows help file.(SCGCQ02145743 port of SCGCQ02141931) - Storcli: /c0 set ? lists bbu,mx,px and lnx commands. (SCGCQ02145756 port of SCGCQ02136689) - Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02145764 port of SCGCQ02136333) - Help note 'page=[x]' needs update(SCGCQ02149062 port of SCGCQ02146823) - Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02153948 port of SCGCQ02150924) - Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02154721 port of SCGCQ02135526) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) - Aero (DBU PA2(SCGCQ02086670 port of SCGCQ02082460) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) - show/set lane speed shows success when we are in SAS profile(SCGCQ02079507 port of SCGCQ02078437) - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all (SCGCQ02047235 port of SCGCQ02040756) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) - Request to Disable DSW3(SCGCQ01903331 port of SCGCQ01896311) - PERCCLI Support for EKMS(SCGCQ01904188 port of SCGCQ01902150) - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01904340 port of SCGCQ01413253) - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921529 port of SCGCQ01220901) - Hide "set termlog" help contents from perccli(SCGCQ01935143 port of SCGCQ01923643) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01940869 port of SCGCQ01937410) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01945534 port of SCGCQ01940805) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01965393 port of SCGCQ01935697) - Storcli shows wrong PD list sequence.(SCGCQ01971632 port of SCGCQ01967488) - LD size not shown in GiB format in foreign import preview(SCGCQ01996370 port of SCGCQ01978978) - Unable to switch to eHBA mode using a H745P Adapter(SCGCQ01998964 port of SCGCQ01990060) - perccli show profile lists personality as JBOD instead of eHBA(SCGCQ01998966 port of SCGCQ01998328) - Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101377 port of SCGCQ02101372) - In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02116733 port of SCGCQ02115036) - complete Lane WWID is not displayed(SCGCQ02145739 port of SCGCQ02145716) - No "Rbld" legend during rebuild. (SCGCQ02150634 port of SCGCQ02146819) - Error message mismatch is seen for rttdump command on iMR Ventura controller.(SCGCQ02160907 port of SCGCQ02156483) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) - Multiple status messages are displayed in the output (SCGCQ02086536 port of SCGCQ02073042) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034200 port of SCGCQ02034064) - Storcli shows wrong PD list sequence.(SCGCQ01977461 port of SCGCQ01967488) - Migrate Failure case is not Branding compliant(SCGCQ02000716 port of SCGCQ01988402) - StorCLI PH12: Retrieving topology details causes application crash in some scenario(SCGCQ02106192 port of SCGCQ02103217) - Support FMP Images in UEFI Version of PERCCli(SCGCQ02116464 port of SCGCQ02078649) - MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02116497 port of SCGCQ02114898) - PH12 PA - StorCLI - 9310-8i IR FW download fails (SCGCQ02121848 port of SCGCQ02121783) - LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02139867 port of SCGCQ02085102) - MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend (SCGCQ02168256 port of SCGCQ02165944) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02079604 port of SCGCQ02018137) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02079597 port of SCGCQ02035437) - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) - Incorrect status displayed for resume copyback command. (SCGCQ02075291 port of SCGCQ02062834) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01929892 port of SCGCQ01106988) - Added new commands from StorCLI(SCGCQ01935296 port of SCGCQ01134166) - For NVMe drive use the term NVMe instead of PCIe (SCGCQ01964024 port of SCGCQ01923119) - securesed autoconfig param should not be present for perccli help(SCGCQ01986879 port of SCGCQ01986831) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032582 port of SCGCQ02029410) - Drives connected to active backplanes not showing the phy info in connector name (SCGCQ02112425 port of SCGCQ02112424) - Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02150630 port of SCGCQ02132024) - Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02153950 port of SCGCQ02150921) - Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02154755 port of SCGCQ02150651) - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) - Port information is not displayed for Vses Backplane (SCGCQ02085875 port of SCGCQ02053070) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC. (SCGCQ02079601 port of SCGCQ01992461) - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) - Storcli: HPE serial number programming and display(SCGCQ02062635 port of SCGCQ01882984) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) - FW flash fails to load the latest image after upgrade downgrade with resetnow option (SCGCQ02046879 port of SCGCQ02035152) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893381 port of SCGCQ01892288) - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01930028 port of SCGCQ01141462) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01936895 port of SCGCQ01935697) - Terminology change from " Data protection" to " Data integrity".(SCGCQ01940807 port of SCGCQ01827339) - Libmods: Terminology change from " Data protection" to " Data integrity".(SCGCQ01943370 port of SCGCQ01827732) - Incorrect colinfo output of Bad block count(SCGCQ01977457 port of SCGCQ01977443) - StorCLI hangs when viewing controller in FreeBSD (MR7.8 is okay(SCGCQ01984543 port of SCGCQ01978824) - Unified StorCLI : Help command of "Get flash" is not shown in generic help syntax(SCGCQ01985472 port of SCGCQ01985463) - StorCLI show output shows Legends as BBU instead of EnergyPack.(SCGCQ01992007 port of SCGCQ01985587) - Aero A0 UTP: StorCLI snapdump command needs to clarify new "On Demand" snapdump option(SCGCQ01995066 port of SCGCQ01993722) - Shenandoah:StorCLI:Right click properties for released binary shown blank.(SCGCQ02000843 port of SCGCQ01988329) - Smart Carrier Enclosure port info shown as "Multuipath"(SCGCQ02008273 port of SCGCQ01992087) - MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json (SCGCQ02116771 port of SCGCQ02112192) - "Storcli /c# set jbod=on" shows success but does nothing (SCGCQ02119067 port of SCGCQ02117219) - Phyreset Fails on IT controllers (SCGCQ02169305 port of SCGCQ02169242) - Storcli stop erase needs an help file update (SCGCQ02169308 port of SCGCQ02168895) - Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02185911 port of SCGCQ02184862) - Storcli connector display not matching with Aero board 9560-16i. (SCGCQ02085681 port of SCGCQ02072448) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) - remove the maxconcurrentpd check from storcli and report fw returned failure (SCGCQ02053931 port of SCGCQ02053910) - PERCCLI Support for EKMS (SCGCQ01904189 port of SCGCQ01903448) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911832 port of SCGCQ01886637) - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915313 port of SCGCQ01222855) - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915315 port of SCGCQ01227144) - perccli /c0 show all lists topology without any DG's present(SCGCQ01998965 port of SCGCQ01998332) - PH12 PA - StorCLI version not getting printed for show file command (SCGCQ02116759 port of SCGCQ02105185) - Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176697 port of SCGCQ02176681) - With IT controller for set or reset with invalid phy is not showing error(SCGCQ02183510 port of SCGCQ02181823) EnhancementRequests: - Incorporating VMware constraints for PERCCLI VIB signing (SCGCQ02190441) - Migrating VMware 64 bit toolchain to 6.8.7-13394445(SCGCQ02190429) - Create an event for DDF config clear failed event.(SCGCQ02173513) - (SCGCQ02162699) - Snap Dump ClearAll Method logging event(SCGCQ02157359) - API changes for a better presentation of Atlas to tools(SCGCQ02149380) - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) - Better error message for certain unmap operations(SCGCQ02111563) - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change(SCGCQ02103973) - MR Windows IOCTL Error codes to Application added to MR API(SCGCQ02103183) - API changes for linkconfig interface (SCGCQ02053671) - API changes for NVMe speed and width changes (SCGCQ02053667) - Reword event log messages as it creates unnecessary panic.(SCGCQ02013675) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949495) - Unified StorCLI : Adding component level download functionality to StorCLI(SCGCQ01940030) - show complete Serial Number and Model Name for NVMe drive(SCGCQ01927541) - snapdump support for host initiated snapdump (SCGCQ01901158) - Changes for disable least latency mode(SCGCQ01891451) - Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01929656) - MR_SAS_Unified_Libmods_7.10 Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01979597) - Post firmware trace buffer at the time of driver load(SCGCQ01992779) - Adding the spare details in the same volume creation(CONFIG_ADD DCMD(SCGCQ02008407) - PSoC implementation in StorCLI by parsing PSoC image(SCGCQ02072160) - Request to display the help for "show" and "set" for JBOD in PercCLI (SCGCQ02160291) - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) - Enable iMR advanced debug dump(SCGCQ02030908) - Unified StorCLI : ARM Windows support to StorCLI(SCGCQ01962294) - Disabling RAID00 support (SCGCQ01960420) - HPE Shenandoah: Branding tool(SCGCQ01960295) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949503) - Unified StorCLI : Allow SBR/SPD read and write using new CBB+SBR concatenated image(SCGCQ01927551) - show complete Serial Number and Model Name for NVMe drive connected to IT controller(SCGCQ01927538) - show complete Serial Number and Model Name for NVMe drive(SCGCQ01919655) - Unified CLI - Command processor changes for handling invalid/tampered device id's for sea IT controllers(SCGCQ01891513) - Add support to display PSOC version for Ventura IT controllers(SCGCQ02067300) - set copyback command changes for cli(SCGCQ02148092) - Unified StorCLI : ARM64 Windows support to StorCLI - LibMod changes(SCGCQ01963208) - Shenandoah: Adding support bit check for delete snap dump(SCGCQ01944500) - Enable iMR advanced debug dump(SCGCQ01873124) - Unified StorCLI : PSoC read and write via Device read and write DCMD's in MR Operational case(SCGCQ01949521) - Changes for disable least latency mode(SCGCQ01891442) - Adding the spare details in the same volume creation (CONFIG_ADD DCMD(SCGCQ02008403) - Unified StorCLI : Allow erase functionality on operational MR using CBB concatenated image(SCGCQ01927595) - Unified CLI : Handling invalid/tampered controllers for sea controllers(SCGCQ01891484) - Requesting StorCLIF to read MR FW from flash device and write it to a file. Similar to what IT FW support.(SCGCQ01631948) - Add ability to field upgrade PSOC on HBA boards(SCGCQ01583214) - DUal Image SUpport(SCGCQ01960287) - Libmods: Porting HPE Shenandoah from Aero to 7.9 (SCGCQ01917263) - Porting HPE Shenandoah from Aero to 7.9(SCGCQ01917172) - Adding HPE specific help for storcli (SCGCQ01935699) 007.0816.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- defects: - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01824574 port of SCGCQ01824569) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01827604 port of SCGCQ01681538) - Updating makefile and EFI's INF changes for ARM StorCLIO(SCGCQ01870684 port of SCGCQ01563125) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) - failure in StorCLI enclosure show status (SCGCQ02043616 port of SCGCQ02040640) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) - perccli /c0 show all lists topology without any DG's present(SCGCQ02085925 port of SCGCQ01998332) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853370 port of SCGCQ01775616) - (SCGCQ01775602 port of SCGCQ01814011) - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) - Storcli shows incorrect output for delete events command (SCGCQ02046875 port of SCGCQ02045816) - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02047747 port of SCGCQ02046036) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) - Drive Size Display Miss Match In Storcli Show Output(SCGCQ02075280 port of SCGCQ02072353) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) - Libmod changes for SCGCQ02090770 (SCGCQ02097658 port of SCGCQ02096774) - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01850374 port of SCGCQ01837932) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02047079 port of SCGCQ02024740) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02047235 port of SCGCQ02040756) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) - show/set lane speed shows success when we are in SAS profile (SCGCQ02079507 port of SCGCQ02078437) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) - Aero (DBU PA2)(SCGCQ02086670 port of SCGCQ02082460) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) - Error message when Maximum number of VDs are reached (SCGCQ01857450 port of SCGCQ01856544) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034200 port of SCGCQ02034064) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) - Multiple status messages are displayed in the output (SCGCQ02086536 port of SCGCQ02073042) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01825986 port of SCGCQ01824570) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01832791 port of SCGCQ01816927) - Add interface in storecli that could get relearn complete status (SCGCQ01850373 port of SCGCQ01848387) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/ eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) - Incorrect status displayed for resume copyback command.(SCGCQ02075291 port of SCGCQ02062834) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread" (SCGCQ02079597 port of SCGCQ02035437) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/ px commands.(SCGCQ02079604 port of SCGCQ02018137) - Aero - LibMod changes for ER SCGCQ01813156 : Addition of Aero and Sea device id's and checkwords (SCGCQ01853418 port of SCGCQ01813626) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) - FW flash fails to load the latest image after upgrade downgrade with resetnow option (SCGCQ02046879 port of SCGCQ02035152) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02079601 port of SCGCQ01992461) - Port information is not displayed for Vses Backplane (SCGCQ02085875 port of SCGCQ02053070) - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) - Add get VPD command support to StorCLI in OS environment (SCGCQ01855067 port of SCGCQ01852603) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) - CSET: Checking in Libmod changes for defect SCGCQ02030652 - (SCGCQ02045948(SCGCQ02047884 port of ) - remove the maxconcurrentpd check from storcli and report fw returned failure (SCGCQ02053931 port of SCGCQ02053910) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02085681 port of SCGCQ02072448) EnhancementRequest: - Updating ncurses library from 6.0 to 6.1(SCGCQ01836749) - Command processor changes for Secure boot properties feature - SCGCQ01855473 (SCGCQ01855503) - Adding secure boot properties to unified StorCLI (SCGCQ01855473) - Adding new MFI STAT - MFI_STAT_SECURE_BOOT_KEY_SLOTS_FULL 007.0711.0000.0000 for Lenovo(SCGCQ01865190) 007.0713.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) - storcli controller show all lists EPD's in VD list(SCGCQ01556595) - controller show all command is not listing the Battery information(SCGCQ01561689) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) - Spell mistake in error message for hwdev command(SCGCQ01614972) - Coverity defect fix for itctflash file(SCGCQ01616369) - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) - Help content for jbodx show unmap is not present(SCGCQ01790130) - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) - storclio command not working to update FW on SATA disk(SCGCQ01918814) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) - Checking in VBAS compliation changes(SCGCQ01630324) - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) - Space need in the output for secure erase(SCGCQ01713604) - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) - Storcli does not display the complete enclosure serial number(SCGCQ01735493) - Storcli vib update fails across releases.(SCGCQ01761795) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) - Removing the set/show of unmap on JBOD.(SCGCQ01817855) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) - CLI does not report Serial number for Enclosure.(SCGCQ01595640) - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) - Update help contents for jbod delete(SCGCQ01624605) - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) - Missing punctuation in Perccli delete config message(SCGCQ01698226) - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) - Drive Fw download Coverity fixes(SCGCQ01615074) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) - Updating the Diag results as per new API changes(SCGCQ01537255) - Resource leaks,Uninitialized variables(SCGCQ01600311) - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) - Removal of ncurses references for linux makefile(SCGCQ01955544) - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) - .(SCGCQ01571935 port of SCGCQ01325052) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) EnhancementRequests - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) - Need Storcli support drive FW upgrade(SCGCQ01583217) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) - MR API changes to support EKMS over OOB(SCGCQ01874035) - Add new error code for tampered or invalid controller(SCGCQ01885686) - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) - Add secure boot key update complete event(SCGCQ01928254) - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) - Add a bit for atomic descriptor capable(SCGCQ01965047) - Add Downgrade Firmware function in Storcli(SCGCQ01583223) - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 007.0525.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects (16) -.(SCGCQ01753405) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) - Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315) - Enclosure show status command gives success but nothing is shown.(SCGCQ01731280) - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927) - Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612) - Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548) - Space need in the output for secure erase.(SCGCQ01713604) - seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619) - Missing punctuation in Perccli delete config message.(SCGCQ01698226) - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) - WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279) - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444) - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795) - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) - Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) - controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704) - Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356) - Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354) - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616) - Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223) - Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983) EnhancementRequests (30) - API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266) - RTTrace Enable/Disable API changes.(SCGCQ01830211) - Criteo: API changes reversal.(SCGCQ01760512) - RTTrace API Changes.(SCGCQ01745568) - API changes needed to support eHBA product series.(SCGCQ01727346) - Create sanitize events.(SCGCQ01713708) - MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730) -.(SCGCQ01593479) -.(SCGCQ01761309) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538) - API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667) - Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538) - Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062) - Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153) - Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319) - Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724) -.(SCGCQ01818580) - Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135) - API change to provide learn complete timestamp.(SCGCQ01845269) - Added Support for Triggering SnapDump.(SCGCQ01848759) - Add secure boot support.(SCGCQ01792416) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487) - Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424) - Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686) - [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480) - Added new events for unmap policy changes.(SCGCQ01871912) - MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021) - API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150) - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528) - Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603) 0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence ------------------- Defects (75) - Profile Mgmt API Changes.( SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing.(SCGCQ00948535) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835) - 800C error when execting Get MFC default function.(SCGCQ01037840) - Enable WB support via API.(SCGCQ01405242) - Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458) - Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920) - Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979) - Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940) - storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171) - Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396) - Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401) - Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745) - Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131) - Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420) - Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852) - Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910) - Detailed help contents were not present for most of the IT download options..(SCGCQ01483760) - Spelling errors in the "/cx restart" command..(SCGCQ01486415) - Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052) - CLI help does not reflect the new command to create an ePD.(SCGCQ01639583) - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964) - Instance Validation is failing for mentioned commands..(SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447) - Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990) - PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588) - Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580) - Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146) - Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694) - PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920) - PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062) - Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041) - Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421) - Checking in VBAS compliation changes.(SCGCQ01630324) - PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798) - Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240) - Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237) - Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214) - MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234) - Adding excludevd option to the help file of patrolread command.(SCGCQ01443435) - PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582) - Schema addition for "show file= " command.(SCGCQ01461209) - PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593) - MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562) - PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762) - Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845) - Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344) - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) - OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785) - Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797) - Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754) - Incorrect help description for erase and download completeflash commands.(SCGCQ01470263) - Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802) - Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833) - Check for supported pages for firing drive SCSI commands.(SCGCQ01474325) - No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900) - IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753) - Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595) - DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683) - Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446) - Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195) - Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334) - Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766) - Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821) - UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749) EnhancementRequests (174) - MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167) - New fault code for routine synchronous reset.(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613) - Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177) - New configuration params added for EPD-PT devices.(SCGCQ01599607) - MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347) - Implement Snapdump debugging capability.(SCGCQ01567770) - Add "Incompatible with Profile" event.(SCGCQ01289924) - API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700) - API change for Simplified RAID10 Creation.(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969) - MPI 2.5: Add new connector types.(SCGCQ01085073) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208) - MPI 2.5: update copyright info.(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175) - Add type BIOS for HashImageType..(SCGCQ00566306) - Identify physical location of a target device.(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293) - MPI 2.5: Signed images for FWDownload.(SCGCQ00469990) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437) - MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512) - Allow Protection Information bit for IR Volume Create.(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request.(SCGCQ00264755) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487) - JSON schema for Drive level commands.(SCGCQ01445435) - MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request.(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272) - MPI 2.6: Enclosure Management.(SCGCQ00345273) - Device Info field for PCIe devices.(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields.(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600) - Modified address space bits.(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563) - MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support.(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541) - MPI 2.6: System Interface Register Set update.(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869) - MPI 2.6: Add new FLASH region types.(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527) - MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088) - MPI 2.6: add PCI Device ID's.(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827) - MPI 2.6: Update Flash Signature..(SCGCQ00852831) - profile management API.(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328) -.(SCGCQ00878757) - Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262) - MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336) - MPI 2.6: Remove all SOP references.(SCGCQ00925839) - Ventura: de-feature AHCI.(SCGCQ00941620) - MPI 2.6: Remove all AHCI references.(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619) -.(SCGCQ00987840) - MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741) - mega api changes for ibuttonless PR.(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821) -.(SCGCQ01082303) -.(SCGCQ01085954) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127) - MPI 2.6: Add new clean tool options.(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267) - Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848) - MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005) - MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760) - MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864) - MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008) -.(SCGCQ01389581) - MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498) - MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515) - Add Test Link Diagnostic API.(SCGCQ01436268) - Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048) - MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138) - Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245) - Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149) - Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045) - Add support for API fields to report SED type of PD.(SCGCQ01587230) - Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520) - NVDATA parameter to OPAL SED.(SCGCQ01614689) - Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350) - Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135) - Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234) - Add support to defeature Cached I/O policy.(SCGCQ01581032) - New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819) - Removing the NMR storcli commands from storcli..(SCGCQ01445268) - Add support to allow Device names greater than 107.(SCGCQ01039328) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213) - MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256) - Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176) - Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628) - Removing the NMR storcli commands from storcli..(SCGCQ01445418) -.(SCGCQ01428114) -.(SCGCQ01423509) - Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987) - Add NVMe device related changes.(SCGCQ01034678) - Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986) - Add boot drive selection support in Stor-CLI.(SCGCQ01445896) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424) -.(SCGCQ01466805) - StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954) - StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799) - Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308) - Add support for IT Firmware images and IT Completeflash images to "show file= " command.(SCGCQ01436882) CSETActivities (57) - StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) - Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483) - Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457) - Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170) - Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237) - SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030) - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) - This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717) - Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154) - Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920) - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698) - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) - Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154) - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) - Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) - Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) - Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526) - Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435) - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) - SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453) - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412) - Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234) - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) - Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628) - Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) - Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900) - DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) - Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460) - Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460) - Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156) - Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214) - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793) - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) - Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754) 0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence ------------------- fixes: - Profile Mgmt API Changes.(SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing.(SCGCQ00948535) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835) - 800C error when execting Get MFC default function.(SCGCQ01037840) - StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715) - PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728) - Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846) - Fixing Error Handling issues and Resource leak.(SCGCQ01319395) - Fix for Libmod files having potential loop errors.(SCGCQ01320336) - Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003) - EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452) - Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604) - Updated the Help.(SCGCQ01375059) - controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816) - Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238) - storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690) - Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373) - storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425) - Fixing out of bounds in libmods.(SCGCQ01385430) - StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177) - Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543) - PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511) - Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756) - Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011) - Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017) - Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239) - Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458) - Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920) - PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897) - Need to handle FW return code change for profile management success case.(SCGCQ01307320) - Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405) - PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477) - Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749) - CLI reports failure when issuie DPM commands.(SCGCQ01333085) - PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041) - Fixing unchecked return values.(SCGCQ01385377) - Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610) - Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922) - LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583) - Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764) - Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948) - Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222) - This is a syntactical error where a comma was added.(SCGCQ01414744) - Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208) - Instance Validation is failing for mentioned commands.(SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216) - StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460) - Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018) - IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046) - Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219) - Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438) - Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534) - Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771) - Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237) - Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214) - Adding excludevd option to the help file of patrolread command.(SCGCQ01443435) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381) - PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757) - Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407) - Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042) - CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639) - Removing the memory leaks in dequelog command.(SCGCQ01411544) - Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758) - Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934) - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306) - Fixing Out of Bounds access and Resource leak.(SCGCQ01304875) - Inconsistencies between the applications for manage link speed.(SCGCQ01389856) - Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106) - Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754) - StorCLI: Spindown help syntax is misleading.(SCGCQ01421610) - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355) - StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149) - Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900) - Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891) - Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748) - Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255) - DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683) - Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890) - Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943) - Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018) - Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024) - storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289) - StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557) - Removing the NMR command for setting SCAPVPD.(SCGCQ01389451) - Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749) EnhancementRequests: - MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167) - New fault code for routine synchronous reset.(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613) - API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700) - API change for Simplified RAID10 Creation.(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969) - MPI 2.5: Add new connector types.(SCGCQ01085073) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208) - MPI 2.5: update copyright info.(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175) - Add type BIOS for HashImageType.(SCGCQ00566306) - Identify physical location of a target device.(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293) - MPI 2.5: Signed images for FWDownload.(SCGCQ00469990) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437) - MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512) - Allow Protection Information bit for IR Volume Create.(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request.(SCGCQ00264755) -.(SCGCQ01421997) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793) - RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354) - Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469) - Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465) - List pending profile details of the controller.(SCGCQ01346308) -.(SCGCQ01291037) - MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request.(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272) - MPI 2.6: Enclosure Management.(SCGCQ00345273) - Device Info field for PCIe devices.(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields.(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600) - Modified address space bits.(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563) - MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support.(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541) - MPI 2.6: System Interface Register Set update.(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869) - MPI 2.6: Add new FLASH region types.(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527) - MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088) - MPI 2.6: add PCI Device ID's.(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827) - MPI 2.6: Update Flash Signature..(SCGCQ00852831) - profile management API.(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328) -.(SCGCQ00878757) - Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262) - MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336) - MPI 2.6: Remove all SOP references.(SCGCQ00925839) - Ventura: de-feature AHCI.(SCGCQ00941620) - MPI 2.6: Remove all AHCI references.(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619) -.(SCGCQ00987840) - MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741) - mega api changes for ibuttonless PR.(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821) -.(SCGCQ01082303) -.(SCGCQ01085954) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127) - MPI 2.6: Add new clean tool options.(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267) - MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819) - always print StorCLI version information at beginning/top of output.(SCGCQ01396733) - StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177) - New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429) - Add support to allow Device names greater than 107.(SCGCQ01039328) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213) - Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628) -.(SCGCQ01428114) - Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646) - Add NVMe device related changes.(SCGCQ01034678) - Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301) - Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079) - Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495) CSETActivities: - StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339) - Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018) - MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993) - The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216) - Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830) - Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790) - MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315) - MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798) - Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785) - SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030) - Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496) - Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485) - ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651) - Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610) - Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565) - Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900) - CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 ) - Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789) - Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152) - Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673) - Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381) - Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320) - MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757) - perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596) - Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529) - Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529) - MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520) - Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274) - MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298) - SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940) - StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843) - Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891) - CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958) - The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 ) - perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993) - StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177) - Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604) - Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294) - StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843) - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152) - C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488) - Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830) - Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993) - ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651) - storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495) - Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145) - Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484) - [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914) - Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309) - Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846) - PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728) - MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756) - MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493) 0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence ------------------- Fixes: - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536) - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913) - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948) - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629) - Code clean up in libmods and sysefi files are added(SCGCQ00359998) - Storcli is returning error with show(SCGCQ00360040) - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814) - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216) - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717) - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455) - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522) - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097) - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248) - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622) - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735) - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000) - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155) - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735) - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364) - portings of AdpRestart command(SCGCQ00378135) - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828) - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104) - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303) - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789) - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832) - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350) - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610) - SWR_1.34(SCGCQ00442652) - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502) - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583) - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843) - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560) - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201) - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579) - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935) - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835) - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123) - Storcli : unable to set patrol read delay(SCGCQ00645195) - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324) - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742) - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131) - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171) - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505) - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647) - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770) - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178) - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183) - Adapters are not listed in sorted order.(SCGCQ00759969) - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398) - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752) - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663) - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712) - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762) - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243) - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789) - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882) - "cpybck" help is not coming in Legends(SCGCQ00784808) - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400) - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232) - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374) - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394) - .(SCGCQ00800878) - Deallocation of the same memory more than once(SCGCQ00802031) - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588) - Out-of-bounds access and array delete misuse(SCGCQ00804680) - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547) - Not able add new VD in Drive Group(SCGCQ00813314) - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939) - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049) - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299) - storcli /call show all fails with "command invalid"(SCGCQ00830269) - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342) - Profile Mgmt API Changes(SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing(SCGCQ00948535) - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835) - 800C error when execting Get MFC default function(SCGCQ01037840) - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936) - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284) - No ISE Capable field(SCGCQ01148693) - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175) - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698) - Fixing Resource leaks(SCGCQ01205356) - resource validation before de referencing(SCGCQ01206104) - Fixing resource leaks in libmods(SCGCQ01208044) - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393) - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414) - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473) - Fix for resource leak in system config show(SCGCQ01210133) - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415) - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383) - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923) - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217) - NVMe PD SMART DATA shows all 0's(SCGCQ01236052) - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715) - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381) - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687) - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688) - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928) - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421) - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632) - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445) - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336) - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979) - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883) - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094) - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474) - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620) - Some sparc structures missing for storcli.(SCGCQ00504585) - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761) - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658) - storecli reports wrong size on 3000MB VD(SCGCQ00644545) - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962) - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672) - Add support bits for uneven-span and SSHA support(SCGCQ00755063) - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101) - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924) - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290) - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959) - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385) - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937) - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658) - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714) - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759) - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347) - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363) - Storcli errors are printing in a different line.(SCGCQ00771626) - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302) - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332) - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577) - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800) - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357) - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202) - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761) - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393) - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335) - Resource leak(SCGCQ00804745) - .(SCGCQ00811452) - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672) - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205) - Fix for profile management support check bit(SCGCQ01208103) - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411) - Unified Storcli: Fixing resource leak issues(SCGCQ01209413) - SAS3.5 Ventura(SCGCQ01219196) - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153) - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169) - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376) - Need to handle FW return code change for profile management success case(SCGCQ01307320) - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263) - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644) - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663) - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978) - storcli /c0 show is not listinf SWR controller(SCGCQ00454971) - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116) - Raptor Galaxy : Storcli(SCGCQ00475562) - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981) - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771) - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763) - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073) - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800) - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416) - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775) - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174) - storelib header file changes porting(SCGCQ00609942) - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023) - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969) - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070) - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000) - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187) - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806) - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918) - Missing the Display of the property temperatureCtrl.(SCGCQ00792264) - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760) - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336) - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206) - Memory not freed which can cause leak(SCGCQ00804554) - Varailble need to be freed before returning in all failure case(SCGCQ00804650) - IDA show incorrect RAID controller type information(SCGCQ00806966) - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197) - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372) - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111) - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464) - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723) - Removing Unused and logically dead code in storcli(SCGCQ01204045) - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492) - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685) - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216) - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332) - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100) - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043) - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956) - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370) - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287) - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672) - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181) - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862) - CPLD(SCGCQ00787705) - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233) - rlListPtr is not handled properly in failure case(SCGCQ00796227) - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392) - LDViewMirror is giving segmentation fault(SCGCQ00830435) - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758) - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321) - Checking in compilation error for Libmods(SCGCQ00919973) - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356) - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055) - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407) - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101) - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709) - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745) - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950) - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070) - debug prints are present when issuing /co/eall show(SCGCQ00475815) - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543) - Verify StorCLI warns on destructive operations(SCGCQ00712982) - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584) - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691) - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358) - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200) - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211) - Incorrect sizeof expression in dcmdprm(SCGCQ00793354) - Non-array delete for objects in rmdatamf(SCGCQ00793361) - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420) - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663) - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672) - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736) - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583) - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306) - PD related information missing for NVMe drives(SCGCQ01126564) - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365) - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854) - StorCLI(SCGCQ01274554) - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911) - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070) - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665) - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107) - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008) - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605) - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355) - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402) - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205) - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334) - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342) - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311) - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117) - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368) - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844) - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353) - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082) - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437) - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721) - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236) - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289) - Help for Compare linkspeed is not complete(SCGCQ01275454) - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037) - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491) - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067) - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426) - Libmod changes to support profile management(SCGCQ01048228) - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627) - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876) - Ventura PH3(SCGCQ01253012) - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455) - coverity removing out of bounds reads from code(SCGCQ01280460) - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999) - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085) - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234) - Resource leak in VdDataMf scanPartitions(SCGCQ00793363) - Storcli can't create AHCI LDs(SCGCQ00897637) - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024) - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214) - Detailed help missing for IT erase commands(SCGCQ01275474) - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671) - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453) Enhancement - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167) - New fault code for routine synchronous reset(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613) - API changes for CR55(SCGCQ01222700) - API change for Simplified RAID10 Creation(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406) - API changes for PR SCGCQ01139678(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954) - API changes for PR SCGCQ01127742(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886) - MR 6.12(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969) - MPI 2.5: Add new connector types(SCGCQ01085073) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208) - MPI 2.5: update copyright info(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175) - Add type BIOS for HashImageType.(SCGCQ00566306) - Identify physical location of a target device(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437) - Allow Protection Information bit for IR Volume Create(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request(SCGCQ00264755) - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183) - Libmods changes for EFI support for Unified storcli(SCGCQ00923719) - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101) - OEL Support for SPARC(SCGCQ00787923) - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010) - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007) - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477) - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399) - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272) - MPI 2.6: Enclosure Management(SCGCQ00345273) - Device Info field for PCIe devices(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600) - Modified address space bits(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568) - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541) - MPI 2.6: System Interface Register Set update(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869) - MPI 2.6: Add new FLASH region types(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527) - MPI 2.6: Extend Task Management(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088) - MPI 2.6: add PCI Device ID's(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827) - MPI 2.6: Update Flash Signature.(SCGCQ00852831) - profile management API(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328) - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740) - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213) - MPI 2.6: Remove all SOP references(SCGCQ00925839) - Change library name to SLIT(SCGCQ00933175) - Ventura: de-feature AHCI(SCGCQ00941620) - MPI 2.6: Remove all AHCI references(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619) - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741) - mega api changes for ibuttonless PR(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127) - MPI 2.6: Add new clean tool options(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267) - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367) - MPI 2.5: Signed images for FWDownload(SCGCQ00469990) - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512) - Display the Storelib version in the show command.(SCGCQ01286063) - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457) - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496) - Add support to allow Device names greater than 107(SCGCQ01039328) - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636) - Enable SED on JBOD(SCGCQ00755527) - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230) - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051) - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474) - Implemented the diag results to print on console(SCGCQ00525321) - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742) - MWCLI. Add HA support into storcli(SCGCQ00352120) - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668) - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607) - Add NVMe device related changes(SCGCQ01034678) - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665) - Complete 240VD support for utilities(SCGCQ00693042) - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287) - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793) - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715) - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821) - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146) - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204) - UDK Support for EFI(SCGCQ00795150) - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171) - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872) - Provide a way to enable or disable 512E using Applications(SCGCQ00351234) - Refer attached design doc(SCGCQ00349599) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495) - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050) - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217) - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344) - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473) - RRB 71(SCGCQ00750164) - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081) - SED/FDE changes for storcli Synchro(SCGCQ00632240) - ASD- StorCLI(SCGCQ00467863) - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209) - PERC 10 WIndows Support(SCGCQ01213160) - PERC 10 WIndows Support(SCGCQ01213157) - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080) - Megacli/storcli support for lmrc driver(SCGCQ00433703) - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093) - Uneven span support is added in StorCLI.(SCGCQ00349548) - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391) - Add EFI support for the manufacturing command to program.(SCGCQ01191095) - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216) - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476) - Monitoring Drive performance and predictive failure(SCGCQ00817977) - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118) - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237) - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987) - Functionality to extract field value from new API changes(SCGCQ00794841) - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815) 0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence ------------------- Enhancement: - Added support for ThinkSystem HBA and RAID. 1.20.20 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227) - Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335) - Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866) - Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811) - Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074) - Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438) - Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663) - Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140) - Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401) - Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258) - Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358) - Fixed an issue where storcli does not display description on command success - (SCGCQ01023973) - Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081) - Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945) - Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534) - Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430) - Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535) - Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218) - Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102) - Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484) - Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534) - Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745) - Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757) - Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895) - Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068) - Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105) - Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314) - Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646) - Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899) - Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101) - Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120) - Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669) - Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997) - Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082) - Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011) - Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071) - Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117) - Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416) - Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387) - Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154) - Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907) - Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447) - Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139) - Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493) - Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500) - Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028) - Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669) - Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536) - Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554) - Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode - (SCGCQ01043063) - Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322) - Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608) - Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994) - Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298) - Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300) - Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088) - Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805) - Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035) - Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084) - Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706) - Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613) - Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775) - Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973) - Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830) - Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940) - Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786) - Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464) - Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466) - Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876) - Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415) - Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985) - Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968) - Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027) - Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756) - Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306) - Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841) - Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876) - Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525) - Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798) - Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620) - Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204) - Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274) - Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667) - Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604) - Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055) - Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533) - Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614) - Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474) - Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758) - Fixed an issue where some commands may not report success on success - (SCGCQ01050695) - Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241) - Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116) - Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773) - Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500) - Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378) - Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493) - Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205) - Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864) - Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540) - Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766) - Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178) - Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305) - Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482) - Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514) - Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493) - Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642) - Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528) - Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477) - Fixed an issue where installaton of storclio may fail - (SCGCQ00952422) - Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981) - Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790) - Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315) - Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178) - Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865) - Fixed an issue where EPD details may not show in "show all" command - (SCGCQ00921937) - Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624) - Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489) - Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330) - Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837) - Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484) - Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697) - Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461) - Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597) - Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760) - Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891) - Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993) - Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617) - Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault" - (SCGCQ01020010, Port of SCGCQ01019547) - Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212) - Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145) - Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101) - Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181) - Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177) - Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789) - Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable - (SCGCQ01143941, Port of SCGCQ01026187) - Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307) - Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download - (SCGCQ01110108, Port of SCGCQ00934755) - Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211) - Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584) Enhancements: - Added the personality change command was not present - (SCGCQ00850610) - Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220) - Added multipath support in EPD configuration options - (SCGCQ01015758) - Added additional CPU support on EFI platform - (SCGCQ01026250) - Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304) - Added personality change features - (SCGCQ01111930) - Added VF-queue depth mode settings - (SCGCQ00907072) - Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320) - Added Secure Erase support to JBOD and System drives - (SCGCQ00929757) - Added a JBOD entity for various operations - (SCGCQ01047229) - Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064) - Added more specific error messages in some circumstances - (SCGCQ00920034) - Added new compilation environment and makefiles - (SCGCQ00920058) - Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739) - Added support for drive microcode update Modes E and F - (SCGCQ01047223) - Added code to display JBOD personality - (SCGCQ01146775) - Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338) - Added new erase type called Crypto - (SCGCQ01050618) - Added new command to set the multiInit EPD parameter - (SCGCQ01080273) - Added support for drive microcode update through parallel loading - (SCGCQ01024964) - Added support for EPD creation - (SCGCQ00887664) - Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414) 1.18.11 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705) - Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785) - Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612) - Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196) - Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339) - Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620) Enhancements: - Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662) - Added the support to set and clear the transport on a DG (SCGCQ00920046) - Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318) - Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795) - Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030) - Provide a more descriptive port enumeration (SCGCQ00854620) - Add support to enable/Disable of Large IO Support (SCGCQ00894644) 1.16.14 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617) - Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176) - Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715) - Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755) 1.16.10 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617) - Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470) - Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914) - Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143) - Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429) - Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770) 1.14.12 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Incorporated StorCLI MegaRAID 6.6 stream Enhancements: - Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171) - Added consistent sorting of controllers using bus, device, function (SCGCQ00696872) - Added ability to enable or disable 512e support (SCGCQ00351234) - Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527) - Added ability for VMWare version to be run from any directory (SCGCQ00642230) - Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477) - Added ability to create a RAID00 (SCGCQ00350668) - Added ability to display the Patrol Read Start Time (SCGCQ00564474) - Added learn cycle progress information in show learn command (SCGCQ00644984) - Added support for uneven spans (SCGCQ00349548) - Added support for lmrc driver (SCGCQ00433703) - Added 240 Virtual Drive support (SCGCQ00693042) - Improved Punctured Block logging (SCGCQ00342399) 1.12.15 - Moderate Impact/Low Probability of Occurrence ------- Fix(es): - Prevent storCLI from allowing users to enable JBOD mode on controllers that do not support JBOD mode. - Updated CACHEBYPASS command to line up with user expectation. When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass. 1.07.07 - Moderate Impact/Low Probability of Occurrence ------- Enhancement(s) - Added support for ServeRAID M1215 SAS/SATA Controller Fix(es): - Fixed an issue where segmentation faults may occur in Linux. - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS. - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying. 1.04.07 - Moderate Impact/Low Probability of Occurrence ------- Enhancement(s) - Added support for ServeRAID M5210e and ServeRAID M5210 Fix(es): - Fixed an issue where a command failure results in subsequent commands and actions failing. - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR. - Added help file for for storcli /cx/dx set security - Fixed an issue where the "show ctrlcount help" command is not displaying properly. - Fixed an issue where a failure is displayed in the output for querying dimmer switch information. - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM. - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives. - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed. - Synced the pause pr command with show pr command to show correct PR Current State. - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property. 1.03.11 - Initial release -------
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |