Firmware Update for Lenovo ThinkSystem Nvme M.2/7mm RAID Enablement Kit
Supported Adapters: ThinkSystem M.2 NVMe 2-Bay RAID Enablement Kit
ThinkSystem 7mm NVMe 2-Bay Rear RAID Enablement Kit
NOTE TO SERVICE - Reference RETAIN #N/A
******************************************************
******************************************************
================================================================================
- Package Version: 20231207
- Changes:
- Modules:
- Firmware: 1.0.20.1054*
- Firmware:
1. Fix NEVOXFW-926: [Lenovo ISCO][STE] Sequences of event in CLI are not continuous. (Events lost issue)
2. Fix NEVOXFW-138: MCTP response may take longer than 100ms on EGS XCC SVT
- OPROM:
1. Fix NEVOXFW-1814: [Lenovo/NevoX] Interrupt vector got changed after load UEFI driver.
================================================================================
================================================================================
================================================================================
- Package Version: 20210707
- Changes:
- Modules:
- Firmware: 1.0.20.1051*
- Firmware:
1. Fix [NEVOXFW-558] System has CPU uncorrectable error during DC cycle with 7mm/M.2 NVMe. (This fix already exists in FW1050)
2. Fix [NEVOXFW-580] hot plug-in PD/VD caused nevox FW hung.
3. Add EP side PHY reset if the Reset done bit(0xE1248158) not set at EP side. Modify Samsung delay function.
4. Fix [FLASHAE-788] ESXi NVMe Driver Offlines NevoX due to Temperature
================================================================================
- Package Version: 20210531
- Changes:
- Modules:
- Firmware: 1.0.20.1050*
- Firmware:
1. Fix [NEVOXFW-21] R3_NevoX_Keep_VD_Status_after_updaing_rawbin
- FW update with Oprom using CLI(in-band)
2. Add error handling for Samsung PM983
1. delay reset :
Add PHY reset if the Reset done bit(0xE1248158) not set.
Modify delay from 100ms to 1000ms for samsung SSD.
2. hotplug:
Add a delay timer(1000ms) at hotplug interrupt to wait Samsung PM983 link up.
3. Fix [NEVOXFW-593][NEVOXFW-560]Critical event string show wrong.
4. Fix [NEVOXFW-335] NevoX controller, VD, PD lost by running FIO test
- FIO write command timeout will cause Nevox lost on host.
- Include the WUNC command to IO count.
- Do not write UNC if command timeout.
5. Fix [NEVOXFW-432] The mnv_cli events lost when use very heavy command.
================================================================================
- Package Version: 20201224
- Changes:
- Modules:
- Firmware: 1.0.20.1049*
- Firmware:
1. Fix NEVOXFW-392 [MI][Known Issue] NVMe admin command with error, the error status will not be cleared
2. Fix NEVOXFW-107 VD is not rebuilding when autorebuild setting is ON
3. Fix NEVOXFW-106 VD delete failed during IO stress test
4. Fix [MI] Controller Health Status Poll, status code bug
5. Add new event:
MNV_NVME_EVT_PD_DFT_ADD
MNV_NVME_EVT_PD_DFT_REMOVE_FIX
MNV_NVME_EVT_PD_DFT_REMOVE_NOT_FIX
MNV_NVME_EVT_PD_READ_ERROR
MNV_NVME_EVT_PD_WRITE_ERROR
================================================================================
- Package Version: 20200930
- Changes:
- Modules:
- Firmware: 1.0.20.1048*
- Firmware:
1. Add MCTP packet sequence number
================================================================================
- Changes:
- Modules:
- Firmware: 1.0.20.1047*
- Firmware:
1. [RAID] Fix bugs:
GLC5622-224 CLI hang up after stopping media patrol
GLC5622-225 CLI hang up after stopping VD initialization
================================================================================
- Package Version: 20200630
- Changes:
- Modules:
- Firmware: 1.0.20.1046*
- Firmware:
1. Fix BMC/OOB FW update issue - overlap error handle bug
2. fix gpio 17 interrupt bug
3. Fix [GLC5622-210] Cli's event doesn't show percentage during initialization.
4. LED predict fail ?SMART warning LED on
===========================================================================
================================================================================
- Package Version: 20200407
- Changes:
- Modules:
- Firmware: 1.0.20.1041*
- Firmware:
1. [198488] M.2/7mm NVMe RAID controller holds SCL low cause XCC can't reach any I2C device on the bus
2. [FIO] Intel platform FIO OS hang issue. Solution: PCIe MSIX TLP, must set RO to 0
3. [R3][187250] JBOD default VD name change to "Drive_x"
4. Let get feature with queue number to return correct IO queue number.
5. Fix JIRA_1531 : NVMe-MI Send(Configuration Get MCTP Transmission Unit Size, Port 0) is failed.
6. [RAID] Fix GLC5060-1532 Plug in PD1 of the old VD(R1). Stop rebuild and restart the host. Degraded R1 will not re-start rebuilding and status becomes functional.
7. Fix GLC5622-137 PD lost after PD reset cycle.
8. Fix RAID0 Data Mismatch/PRP Error.
9. Fix Auto Rebuild dose not start in some scenarios.
Lenovo Data Center Group Linux OS Support Home Page |
| linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
Mnvcli (Command Line) Utility for Storage Management
Adapters Supported:
ThinkSystem M.2 NVMe 2-Bay RAID Enablement Kit for 4Y37A09750
ThinkSystem 7mm NVMe 2-Bay Rear RAID Enablement Kit for 4XH7A60928
NOTE TO SERVICE - Reference RETAIN #N/A