Bundle Release Information: |
Targeted Server Family (Machine Type): Lenovo ThinkSystem SR635 (7Y98, 7Y99) |
Targeted Operating System: SLES12SP5 |
YUM Repository Build Date: 2024_08_23 |
Device: |
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter |
![]() Device Product Guide |
Part Number: 7Y37A01083 Feature Code: na |
|||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0600 |
Release History: |
Release Change History Documents |
BIOS and Firmware Update for ThinkSystem RAID 730-8i XGB Cache PCIe 12Gb Adapter Supported Adapters: ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter ThinkSystem RAID 730-8i 2GB Cache PCIe 12Gb Adapter NOTE TO SERVICE - Reference RETAIN #N/A Version 24.21.0-0151 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0151 BIOS: 6.36.00.3 UEFI Driver:0x06180205 HII:03.25.05.14 MR NVDATA:3.1705.00-0024 iMR NVDATA - 3.1705.01-0018 MR Firmware - 4.680.00-8561 iMR Firmware - 4.680.01-8560 Version 24.21.0-0140 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0140 BIOS: 6.36.00.3 UEFI Driver:0x06180204 HII: 03.25.05.14 MR NVDATA: 3.1705.00-0024 iMR NVDATA - 3.1705.01-0017 MR Firmware - 4.680.00-8539 iMR Firmware - 4.680.01-8538 Version 24.21.0-0112-1 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0112 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.12 MR NVDATA: 3.1705.00-0020 iMR NVDATA - 3.1705.01-0012 MR Firmware - 4.680.00-8489 iMR Firmware - 4.680.01-8488 Version 24.21.0-0113 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0113 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.10 MR NVDATA: 3.1705.00-0018 iMR NVDATA - 3.1705.01-0012 MR Firmware - 4.680.00-8491 iMR Firmware - 4.680.01-8490 Version 24.21.0-0108 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0108 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.12 MR NVDATA: 3.1705.00-0020 iMR NVDATA - 3.1705.01-0012 MR Firmware - 4.680.00-8480 iMR Firmware - 4.680.01-8481 Version 24.21.0-0097 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0097 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.12 MR NVDATA: 3.1705.00-0018 iMR NVDATA - 3.1705.01-0012 MR Firmware - 4.680.00-8458 iMR Firmware - 4.680.01-845 MR 6.14 defects: - Release Version - MR_FW_SAS3_6.14 (2) - GCA Release Version 00.72.00.03 - MR_FW_SAS_Mega_API (2)(SCGCQ01943823) - Pre-Alpha Release Version 005.028.000.000 - MR_FW_SAS_Mega_API (1)(SCGCQ01851145) - Alpha Release Version 005.030.000.000 - MR_FW_SAS_Mega_API (1)(SCGCQ01881298) - ReleaseCandidate Release Version 005.036.000.000 - MR_FW_SAS_Mega_API (1)(SCGCQ01940381) - Point Release Version 07.0800.0200.0100 - MR_FW_SAS_Mega_API (4)(SCGCQ01963790) - Pre-Alpha Release Version 0x07100000 - MR_FW_SAS_Mega_API (2)(SCGCQ01957805) - Alpha Release Version 2.33 - MR_FW_SAS_Mega_API (2)(SCGCQ01916056) - Pre-Alpha Release Version 4.680.00-8326 - MR_FW_SAS3_6.14_Criteo (1)(SCGCQ01601410) - Pre-Alpha Release Version 4.680.00-8328 - MR_FW_SAS3_6.14_Criteo (1)(SCGCQ01628338) - Beta Release Version 4.680.00-8361 - MR_FW_SAS3_6.14_Criteo (1)(SCGCQ01803370) - Point Release Version 4.680.00-8429 - MR_FW_SAS3_6.14 (1)(SCGCQ01940950) - Point Release Version 4.680.00-8436 - MR_FW_SAS3_6.14 (4)(SCGCQ01964013) - Point Release Version 4.680.00-8438 - MR_FW_SAS3_6.14_Point (1)(SCGCQ01990276) - Beta Release Version 4.680.00-8440 - MR_FW_SAS3_6.14_Criteo (3)(SCGCQ01995309) - Point Release Version 4.680.00-8442 - MR_FW_SAS3_6.14 (2)(SCGCQ02001171) - Point Release Version 4.680.00-8444 - MR_FW_SAS3_6.14 (1)(SCGCQ02036836) - Point Release Version 4.680.00-8446 - MR_FW_SAS3_6.14 (1)(SCGCQ02044956) - Point Release Version 4.680.00-8450 - MR_FW_SAS3_6.14 (2)(SCGCQ02077217) - Alpha Release Version 4.680.00-8452 - MR_FW_SAS3_6.14 (1)(SCGCQ02082275) - Point Release Version 4.680.00-8454 - MR_FW_SAS3_6.14 (2)(SCGCQ02100174) - Alpha Release Version 4.680.01-8358 - MR_FW_SAS3_6.14_Criteo (1)(SCGCQ01775668) - Beta Release Version 4.680.01-8359 - MR_FW_SAS3_6.14_Criteo (2)(SCGCQ01789201) - Point Release Version 4.680.01-8373 - MR_FW_SAS3_6.14_Criteo (1)(SCGCQ01818017) - Alpha Release Version 4.680.01-8421 - MR_FW_SAS_Mega_API (2)(SCGCQ01927186) - Alpha Release Version 4.680.01-8424 - MR_FW_SAS3_6.14 (1)(SCGCQ01929242) - Beta Release Version 4.680.01-8426 - MR_FW_SAS3_6.14 (1)(SCGCQ01934634) - Beta Release Version 4.680.01-8428 - MR_FW_SAS3_6.14 (2)(SCGCQ01936596) - Beta Release Version 4.680.01-8441 - MR_FW_SAS3_6.14_Criteo (6)(SCGCQ01995312) - Point Release Version 4.680.01-8443 - MR_FW_SAS3_6.14 (2)(SCGCQ02001928) - Point Release Version 4.680.01-8445 - MR_FW_SAS3_6.14 (2)(SCGCQ02036925) - Point Release Version 4.680.01-8447 - MR_FW_SAS3_6.14 (1)(SCGCQ02045005) - Point Release Version 4.680.01-8451 - MR_FW_SAS3_6.14 (1)(SCGCQ02077220) - Alpha Release Version 4.680.01-8453 - MR_FW_SAS3_6.14 (1)(SCGCQ02082278) - Point Release Version 4.680.01-8455 - MR_FW_SAS3_6.14 (1)(SCGCQ02100177) - Point Release Version 4.680.01-8459 - MR_FW_SAS3_6.14 (1)(SCGCQ02124527) - Point Release Version 4.740.00-8432 - MR_FW_SAS_Mega_API (6)(SCGCQ01964017) - Point Release Version 4.740.00-8433 - MR_FW_SAS3_6.14 (2)(SCGCQ01990295) - Point Release Version 4.740.00-8434 - MR_FW_SAS3_6.14_Criteo (10)(SCGCQ02047944) - Point Release Version 4.740.00-8435 - MR_FW_SAS3_6.14 (1)(SCGCQ02112078) - Beta Release Version 4.740.00-8436 - MR_FW_SAS3_6.14 (2)(SCGCQ02137452) - Beta Release Version 5.080.02-2362 - MR_FW_SAS_Mega_API (2)(SCGCQ02132036) - Pre-Alpha Release Version 5.090.00-1810 - MR_FW_SAS_Mega_API (1)(SCGCQ01957200) - Beta Release Version 5.090.00-1983 - MR_FW_SAS_Mega_API (1)(SCGCQ02018875) - Pre-Alpha Release Version 5.090.02-1830 - MR_FW_SAS_Mega_API (1)(SCGCQ01964183) SATA PD does not change to failed state after read medium error detected(SCGCQ01624704) - Repetitive OOB and LED prints observed in FW logs(SCGCQ01727104) - FW Crashes when user tries to fetch SMP PassThru Info using Host SLT(SCGCQ01937319) - Do not allow RAID config in JBOD-WB mode and prevent change of personality if WB mode is set(SCGCQ01685447) - dev defect - Setting defaults for JBOD-WB mode and code cleanup(SCGCQ01681100) - Cannot create or mount xfs filesystem using xfsprogs 4.19.x kernel 4.20(SCGCQ02027889) - xfs_info command run on an XFS file system created on a VD of strip size 1M shows sunit and swidth as 0(SCGCQ02056038) - CV going into WT mode during learn after upgrading to versions later than 24.18.0-0021 - FW fault after factory defaults(SCGCQ02060813) - After using hdparm to lock a SATA SSD JBOD drive the drive fails to be unlocked by the MR FW on reboot(SCGCQ02083536) - Kill adapter observed while running target reset on JBOD WB(SCGCQ01789188) - SMp command failure in OOB Path(SCGCQ01927021) - HDET_MR 6.14: OOB - SCSI PassThru Command fails with error code 0x2E (SCGCQ01936541) - Once pinnedcache is set to off not able to toggle field value in JBOD WB mode(SCGCQ01671213) - PL Fault observed while running target reset on JBOD WB(SCGCQ01676164) - MR 6.14: FW reported incorrect value for max data transfer request size as 4 MB in Storcli app.(SCGCQ02023160) - Kill Adapter observed while running task management on JBOD-WB with IO's (SCGCQ02009801) - Max number of PDs for PatrolRead to run concurrently should be in range from 1 to MR controller's max configurable PDs(SCGCQ02008420) - Some Configured drives may change to JBOD and Unconfigure Good after Set JBOD=on and reboot(SCGCQ02080101) - MR controller was missing in UEFI after reboot when the bootable JBOD drive was removed(SCGCQ02112533) - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND (SCGCQ01882581) - MR 6.14 - PD show all StorCLI command fails for UBAD SAS & SATA drives (SCGCQ01915285) - With ESXi 6.7 OS or latter, a SATA SSD drive that is configured as EPD will be dropped by OS when driver reload is done(SCGCQ01969605) - Dev defect: Incorporate the new changes done in MR API(SCGCQ01760667) - Amber LED not seen for UBAD PD's (SCGCQ01770256) - Continuous SRAM correctable error prints followed by controller reset(SCGCQ02023839) - Able to create RAID configuration even after it has been disabled(SCGCQ01670086) - With a pending personality change, Global hot spares are allowed to be created and should be blocked.(SCGCQ01750315 port of SCGCQ01742187) - SMP pass through not working when the “PD 0” is BAD drive(SCGCQ01945674 port of SCGCQ01945602) - (CSETActivity) - MCTP over PCIe discovery(SCGCQ01904092 port of SCGCQ01184923) - CIT: Same EID assigned to 2 930-8i controllers(SCGCQ01886616 port ofSCGCQ01830180 ) - Controller OCR seen when DM multipathing issues read CDB with zero blocks(SCGCQ01822167 port of SCGCQ01808882) - Unable to recover config when changing security password before re-inserting drives(SCGCQ01874302 port of SCGCQ01715058) - 23=Flash programming error while upgrading the Controller FW causes the APP image corruption(SCGCQ02085501 port of SCGCQ02074630) EnhancementRequest: - RTTrace Enable/Disable API changes(SCGCQ01830211) - MR API changes to support EKMS over OOB(SCGCQ01874035) - API Changes for Driver/FW DCMD HandShake(SCGCQ01841266) - Added new events for unmap policy change(SCGCQ01871912) - Add secure boot key update complete event(SCGCQ01928254) - Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424) - Unmap: Define new events for enhanced UNMAP support [MR7.8](SCGCQ01803319) - Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure(SCGCQ01816724) - [MR 7.8] API change to return apt failure status for a personality change request(SCGCQ01853480) - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers (SCGCQ01886424) - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) - Add secure boot support(SCGCQ01792416) - API change to provide learn complete timestamp(SCGCQ01845269) - POC in 6.14: WB support and Pinned Cache changes(SCGCQ01581022) - Aero FW - Reporting SSD wear gauge values for OEM specific customers(SCGCQ01798686) - Support SC_INQUIRY and SC_LOG_SENSE SCSI Passthrough commands on drives in bad state for a particular OEM(SCGCQ01888257) - FW changes for the configurable parameters(SCGCQ01609320) - Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135) - API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot(SCGCQ01765150) - Add new MFI Status - MFI_STAT_PD_NOT_ELIGIBLE_FOR_LD (SCGCQ01818580) - HDET: Support smp passthrough in storlib and storeliboob (SCGCQ01799154) - Fail the drive and do not pin the cache(SCGCQ01584411) - Integrated Invader PL RO - SCGCQ02000507– phase 14, Version 14.00.11.00 to MR 6.14(SCGCQ02000920) - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) - Added Support for Triggering SnapDump(SCGCQ01848759) - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) Version 24.21.0-0084-1 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0084 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.11 NVDATA: 3.1705.00-0018 iMR NVDATA - 3.1705.01-0012 Firmware - 4.680.00-8434 iMR Firmware - 4.680.01-8435 MR 6.14 Defects: - SATA SSD not discovered by OS during hibernate test.(SCGCQ01949781) - Intruder and Invader controllers returnning vpd86 error.(SCGCQ01929277) - FW reports that the board passed BBU Retention test on boards that have a non operational ONFI NAND memory.(SCGCQ01891177 Port Of Defect SCGCQ01934351) - Invader IMR : PD fails to get marked as foreign on insertion.(SCGCQ01950845 Port Of Defect SCGCQ01955263) - Preserved Cache doesn't flush back during Foreign Import.(SCGCQ01466831 Port Of Defect SCGCQ01904085) Version 24.21.0-0076-1 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0076 BIOS: 6.36.00.3 UEFI Driver: 0x06180203 HII: 03.25.05.10 NVDATA: 3.1705.00-0018 iMR NVDATA - 3.1705.01-0012 Firmware - 4.680.00-8417 iMR Firmware - 4.680.01-8406 Defects (8) - 'CacheVault Flash Size' is showing as 3.0 GB after upgrading FW when it should show 4.0 GB.(SCGCQ01615779) - criteo: Storcli shows R0 VD as WB in JBOD personality where as FW shows in WT mode.(SCGCQ01714445) - Revert code changes from CSET SCGCQ01569257.(SCGCQ01717743) - Customer specific 3108 PCIe add-on card fails to come back while resuming from sleep state S.(SCGCQ01718911) - FW returns success for enabling encryption when it is failed on the drives.(SCGCQ01830718) - Line 535 in ../../raid/cachePreserve.c for trying to create Pinned Cache by Cable Pull..(SCGCQ01839662) - memset the deviceStateLedBitmap properly.(SCGCQ01844264) - OOB SCSI passthru command (READ DEFECT 12) return without response data.(SCGCQ01793262) - FW is observing Kill Adapter while CCVD disassociate in progress.(SCGCQ01186806 port of SCGCQ01172369) - Update the MAXTransferLength properly for Driver enabled 1MB support feature.(SCGCQ01238543 port of SCGCQ01232275) - FW crashes when FW update(OFU) is done with faluty onfi.(SCGCQ01249569 port of SCGCQ01227115) - irq handler flooding taskqueue and persistent ID removal corrupting memory.(SCGCQ01399132 port of SCGCQ01299784) - Firmware allows to add bad blcoks beyond actual number of blocks..(SCGCQ01430024 port of SCGCQ01403292) - MCTP: Addressing PCIe credirt free issue..(SCGCQ01447186 port of SCGCQ01446811) - Firmware discovery is not listing all the drives after removal/insert Enclosure Cable with IO.(SCGCQ01579250 port of SCGCQ01555943) - MR FW memory Leak across driver load/unload.( SCGCQ01579251port of SCGCQ01573393) - With controller operating in least latency mode, FW hits montask upon running IOs.(SCGCQ01587048 port of SCGCQ01116419) - Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01635416 port of SCGCQ01623254) - Issue: JBOD devices were dropped after unloading driver and reloading driver in linux.(SCGCQ01639846 port of SCGCQ01566087) - : FW asserts when invalid parameters to set excluded ld for CC is sent to firmware..(SCGCQ01670394 port of SCGCQ01635729) - Colusa SAS expander reset results in unpredictable performance.(SCGCQ01697517 port of SCGCQ01455811) - MR 7.6 - "NVCache has gone bad" during POST after flashing the latest package 1226 and rebooted.(SCGCQ01714326 port of SCGCQ01635062) - When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM..(SCGCQ01715349 port of SCGCQ01676080) - F/W Hangs during reboot.(SCGCQ01716602 port of SCGCQ01616551) - MR7.6: Firmware hit montask running task management reset in loops.(SCGCQ01727364 port of SCGCQ01675742) - When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM.(SCGCQ01729680 port of SCGCQ01676080) - LAS does not show proper state of secured locked drives..(SCGCQ01732045 port of SCGCQ01615781) - F/W Hangs during reboot.(SCGCQ01758976 port of SCGCQ01616551) - Pd firmware download timer is calculated accordingly.(SCGCQ01758988 port of SCGCQ01669508) -.(SCGCQ01763953 port of SCGCQ01749090) - Smart Return Status passthru command failed on SATA drives.(SCGCQ01806402 port of SCGCQ01555033) - LAS does not show proper state of secured locked drives..(SCGCQ01807819 port of SCGCQ01615781) -.(SCGCQ01838484 port of SCGCQ01807938) - 9460-8i is reporting Chip Temperature of 255 when the ambient temp is about 0 C.(SCGCQ01850339 port of SCGCQ01565568) - Found invalid event.(SCGCQ01375915 port of SCGCQ01347858) - 9460-16i disappears from F1 setup after encrypting SED.(SCGCQ01565312 port of SCGCQ01326871) - Sanitize Support.(SCGCQ01577753 port of SCGCQ01526323) - Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01633668 port of SCGCQ01623254) - Sanitize progress in TTY log showing incorrect elapsed time.(SCGCQ01681594 port of SCGCQ01630577) - Pd firmware download timer is calculated accordingly.(SCGCQ01682987 port of SCGCQ01669508) EnhancementRequests (11) - Integrate phase 12 PL (12.00.13.00) with MR 6.12.(SCGCQ01580766) - FW change: Request to add NVDATA and PNP IDs for new card introduction.(SCGCQ01826466) - Integrate Intruder Phase 14 PL - 14.00.10.00 Firmware MR PL Release.(SCGCQ01764776) - Criteo: API changes reversal.(SCGCQ01760512) - PL Integration: Integrate Intruder PL phase 13.00.10.00 with MR 6.13 Intruder.(SCGCQ01698033) - PL Integration : Integrate Invader phase 12.00.14.00 PL with MR 6.12.(SCGCQ01716598) - RTTrace API Changes.(SCGCQ01745568) - Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled..(SCGCQ01757538) - Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062) - Adding API bit to indicate whether forced personality change is supported or not..(SCGCQ01762153) - PL Integration: Integrate Invader Phase 13.00.10.00 PL with MR 6.13 Invader.(SCGCQ01698045) Version 24.21.0-0052-1 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0052 BIOS: 6.36.00.2 UEFI Driver: 0x06180202 HII: 03.25.05.04 NVDATA: 3.1705.00-0014 iMR NVDATA - 3.1705.01-0011 Firmware - 4.680.00-8353 iMR Firmware - 4.680.01-8354 Defects (42) - Intruder Controller Disappear during clean shutdown on OEM server.(SCGCQ01375977) -.(SCGCQ01753405) -.(SCGCQ01749090) - When NVRAM value is read from cached address ,primary core reads stale value and skips writing to NVRAM..(SCGCQ01676080) - Pd firmware download timer is calculated accordingly.(SCGCQ01669508) - IO path function accessed by both core is not synchonized..(SCGCQ01640234) - False alarm of "cache Discarded" when the System, with Invader controller + WT R5 volume, is shutdown normally..(SCGCQ01627751) -.(SCGCQ01623408) - Increase the recon BB list entries to align with BBM MAX BAD entries.(SCGCQ01623254) - MR FW memory Leak across driver load/unload.(SCGCQ01573393) - Incorrect Micron NAND Model Number read from flash.(SCGCQ01531136) - MR_6.14 PACK 23 - On performing a cable pull/push operation during drive is in failed state, result to MonTask.(SCGCQ01529830) - [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01497858) - IO access to iMR FW will fail after sveral powercycle.(SCGCQ01494761) - iMR Compilation fails even with RELEASE option in 6.12 after taking errata MR workaround SCGCQ01323607 and its child defects.(SCGCQ01494566) - SED Drive become UBad during secure erase on MegaRAID 9361-8i controller.(SCGCQ01473188) - 6.14 : Reverting the sysDma changes.(SCGCQ01465727) - On iMR Invader & for 2 enclosures connected in cascaded multi path , power off and then power on the 1st enclosure, PDs not getting detected.(SCGCQ01455949) - Firmware upgrade/downgrade operation failing on SKINNY controller.(SCGCQ01455133) - MCTP: Addressing PCIe credirt free issue..(SCGCQ01446811) - Parameter Page Invalid, Setting channel count based on DDR Size..(SCGCQ01440768) - FW breaks into montaks with pinned cache and foreign configuration.(SCGCQ01378970) - FW reported tmm Date of Manufacture 15/25/6.(SCGCQ01395084) - Interrupting Offload will Lead to Next offload cycle to fail.(SCGCQ01399701) - Enable WB support via API.(SCGCQ01405242) - F/W Hangs during reboot.(SCGCQ01616551) - iMR compilation breaks, exceeding 1MB flash region allocated.(SCGCQ01520940) - Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01514867) - Workaround for IO access to iMR FW will fail after sveral powercycle on 3004 controller..(SCGCQ01507504) - linker error resolved.(SCGCQ01472217) - Problem with I2C Slave communication with external Masters that don’t support slave clock stretching..(SCGCQ01443277) - MR : Cache data Lost when Term Log is set to "on" and grown bad blocks are there in the controller.(SCGCQ01394288) -.(SCGCQ01400707) - Learn cycle shown as active when Learn cycle fails.(SCGCQ01400807) - Firmware allows to add bad blcoks beyond actual number of blocks..(SCGCQ01403292) - OCR getting disabled after NVRAM delete.(SCGCQ01719006) - MCTP : Porting of firmware download fixes from Ventura.(SCGCQ01439651) - NVCache state not transitioning from 'Faulty' to 'Ok' until after reboot.(SCGCQ01395724) - Intermittent: On iMR_Invader & cascaded Enclosures, after power off the enclosure, FW holds the PD info and apps display PDs.(SCGCQ01483727) - controller VPD info is hidden as per OEM request.(SCGCQ01454973) - SSD SATA JBOD discovered as 0.0MB after re-loading the same driver..(SCGCQ01446965) - Firmware discovery is not listing all the drives after removal/insert Enclosure Cable with IO.(SCGCQ01555943) - Infinite loop in onfiSyncModeEnter.(SCGCQ01259314 port of SCGCQ00329024) - HW workaround implementation for SCGCQ00830272 and SCGCQ01048567.(SCGCQ01326393 port of SCGCQ01323607) - MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address.(SCGCQ01334364 port of SCGCQ01332947) - Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348660 port of SCGCQ01304521) - Resulting R0 VD is showing as not consistent after reconstruction..(SCGCQ01348998 port of SCGCQ01288897) - Imr Invader FW crashes while upgrading from Pkg 24.18.0-0021 to Pkg 24.21.0-0007..(SCGCQ01351814 port of SCGCQ01342601) - Intruder 4G DDR tuning value has to be changed in MR FW..(SCGCQ01369344 port of SCGCQ01368845) - Found invalid event.(SCGCQ01375914 port of SCGCQ01347858) - Placement of an image checkword at data area of NOR flash leads to controller crash.(SCGCQ01375943 port of SCGCQ01375071) - Block OCR after Clearing NVRAM.(SCGCQ01392471 port of SCGCQ01386919) - Block OCR after Clearing NVRAM.(SCGCQ01394920 port of SCGCQ01386919) - SCS/PL debug logs for "rb", "tb", or "dmdiag pl dbg" are sometimes mangled due to multiple mprintf's overlapping.(SCGCQ01399457 port of SCGCQ01283702) - RedBrick controller hang at DCR Err Logg Address 29e02..(SCGCQ01412795 port of SCGCQ01375159) - RedBrick controller hang at DCR Err Logg Address 29e02..(SCGCQ01412827 port of SCGCQ01375159) - LSA hangs when user try to change drive security key..(SCGCQ01412848 port of SCGCQ01342655) - B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B).(SCGCQ01412896 port of SCGCQ01271186) - Parameter Page Reads fail during ONFI bringup..(SCGCQ01415428 port of SCGCQ01413557) - heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421932 port of SCGCQ01411591) - heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421933 port of SCGCQ01411591) - heck Consistency doesn't identify double media errors once aborting and starting CC again.(SCGCQ01421934 port of SCGCQ01411591) - Revert the DDR tuning values back to default value.(SCGCQ01446963 port of SCGCQ01444640) - PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01446983 port of SCGCQ01399026) - MCTP: Addressing PCIe credirt free issue..(SCGCQ01447187 port of SCGCQ01446811) - Parameter Page Invalid, Setting channel count based on DDR Size..(SCGCQ01447901 port of SCGCQ01440768) - Drives in Enclosure spin up values for OEM board is not initialized correctly.(SCGCQ01466081 port of SCGCQ01450221) - IOMMU fault at address 0x80360000.(SCGCQ01473355 port of SCGCQ01279547) - Enable DO_REAL_TIME_ISP and DO_DISABLE_ISP_CLAMP flags while flashing CPLD for Intruder cards.(SCGCQ01503730 port of SCGCQ01452026) - SED Drive become UBad during secure erase on MegaRAID 9361-8i controller.(SCGCQ01503736 port of SCGCQ01473188) - [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01519905 port of SCGCQ01497858) - MR_6.14 PACK 23 - On performing a cable pull/push operation during drive is in failed state, result to MonTask.(SCGCQ01532358 port of SCGCQ01529830) - OCR is disabled by default is RC build, even NVDATA if it is enabled..(SCGCQ01540279 port of SCGCQ01503204) - MR7.1/7.3 Termlog/UARTlog - messages sometimes missed in Termlog.(SCGCQ01540361 port of SCGCQ01498188) -.(SCGCQ01569257 port of SCGCQ01097035) - If an INVALID applicationMsgTag id received, then failed the command with MFI_OOB_STATUS_INVALID_CMD using command id MAX_OOB_COMMANDS..(SCGCQ01575976 port of SCGCQ01337332) - Sanitize Support.(SCGCQ01577752 port of SCGCQ01526323) - SATA PassTrough commands with check condition taking long time to complete..(SCGCQ01582512 port of SCGCQ01561887) - VMware Passthrough Adapter does not sync time on VM power on.(SCGCQ01595865 port of SCGCQ01592800) - Jbod become Ugood sometimes after reboot.(SCGCQ01616609 port of SCGCQ01508978) - Colusa SAS expander reset results in unpredictable performance.(SCGCQ01618030 port of SCGCQ01455811) - 'CacheVault Flash Size' is showing as 3.0 GB after upgrading FW when it should show 4.0 GB.(SCGCQ01640816 port of SCGCQ01615779) - Drives are reverted back to JBOD after perfoming instant secure erase.(SCGCQ01683366 port of SCGCQ01615777) - MR7.1/7.3 Termlog/UARTlog - messages sometimes missed in Termlog.(SCGCQ01714377 port of SCGCQ01498188) - In HII whether entering the correct pass phrase or the wrong pass phrase a secured SED becomes unsecured.(SCGCQ01715297 port of SCGCQ01301947) - B200 M5 / Carmel (3108 iMR) - VSAN failure during controller reset test.(SCGCQ01760837 port of SCGCQ01397566) - MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations.(SCGCQ01339329 port of SCGCQ01332706) - MR : Cache data Lost when Term Log is set to "on" and grown bad blocks are there in the controller.(SCGCQ01403930 port of SCGCQ01394288) - Interrupting Offload will Lead to Next offload cycle to fail.(SCGCQ01403958 port of SCGCQ01399701) - SSD SATA JBOD discovered as 0.0MB after re-loading the same driver..(SCGCQ01447007 port of SCGCQ01446965) - MCTP : Porting of firmware download fixes from Ventura.(SCGCQ01447173 port of SCGCQ01439651) - Controller crash observed while running OLTP workload (4K and 16K 16QD).(SCGCQ01447780 port of SCGCQ01438216) - PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01467708 port of SCGCQ01399026) - [Factory issue] MR 3108 controller BIOS stop at 3 different initialization screen.(SCGCQ01519906 port of SCGCQ01497858) - Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01521684 port of SCGCQ01514867) - Event Log Corruption..(SCGCQ01532399 port of SCGCQ01451417) - Rebuild Rate %100 takes much longer time than %30 while running IO. It should take much shorter time..(SCGCQ01540424 port of SCGCQ01336908) - Controller crash observed while running OLTP workload.(SCGCQ01565253 port of SCGCQ01447773) - OEM iMR 8i controller fails to complete an OCR.(SCGCQ01565318 port of SCGCQ01330611) - Snap3 : Drives drops while running transformation operation on R1 to R5 with 900 Medium errors.(SCGCQ01598538 port of SCGCQ01581661) - LSA shows Stop Erase option for VDs on which Erase operation is not in progress.(SCGCQ01605097 port of SCGCQ01600267) - Memset the PinnedDataStructure when DRAM dirty signature is zero.(SCGCQ01724925 port of SCGCQ01713149) - Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348657 port of SCGCQ01304521) - Firmware crashes during medium error recovery and Rebuild.(SCGCQ01348658 port of SCGCQ01304521) - FW is not correctly reporting Hide VD operation as not supported.(SCGCQ01348841 port of SCGCQ01274084) - MR7.3: 4k PD Configuration can't be imported from iMR to MR Controller. However, it can be imported from MR to iMR.(SCGCQ01402828 port of SCGCQ01395842) - PL considers Timer Handle=0 and invalid, MR FW did not..(SCGCQ01467725 port of SCGCQ01399026) - Extend iMR change of trap related data should be in same module as trap ISR..(SCGCQ01520788 port of SCGCQ01514867) - MR 7.6 - "NVCache has gone bad" during POST after flashing the latest package 1226 and rebooted.(SCGCQ01683358 port of SCGCQ01635062) - Controller hang with FDE Drive (Micron 510DC).(SCGCQ01328038 port of SCGCQ01304133) - Assertion failure in ../../mros/mem.c : mb->tag==tag.(SCGCQ01539460 port of SCGCQ01515324) - Parameter Page Reads fail during ONFI bringup..(SCGCQ01415424 port of SCGCQ01413557) - If an INVALID applicationMsgTag id received, then failed the command with MFI_OOB_STATUS_INVALID_CMD using command id MAX_OOB_COMMANDS..(SCGCQ01512549 port of SCGCQ01337332) EnhancementRequests (47) - New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051) - Provide customized default smartpollinterval to 30 for iMR3004 product.(SCGCQ01748252) - RTTrace API Changes.(SCGCQ01745568) - API changes needed to support eHBA product series.(SCGCQ01727346) - Create sanitize events.(SCGCQ01713708) - Memset the PinnedDataStructure when DRAM dirty signature is zero.(SCGCQ01713149) - Integrate latest phase 14.0 - 14.00.08.00 PL with MR 6.14.(SCGCQ01682170) - as per customer request enabled FBU02 and 4G TFM support.(SCGCQ01681106) - Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177) - New configuration params added for EPD-PT devices.(SCGCQ01599607) - MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347) - Integrate latest phase 14 PL with MR 6.14.(SCGCQ01593998) - Integrate Invader Phase 14 PL - 14.00.06.00 Firmware MR PL Release.(SCGCQ01589431) - Add support to defeature Cached I/O policy.(SCGCQ01581032) - Implement Snapdump debugging capability.(SCGCQ01567770) - Integrate Intruder phase 14 PL - 14.00.08.00 with MR 6.14 Intruder.(SCGCQ01459161) - customer request for GPIO support..(SCGCQ01452102) - Enable DO_REAL_TIME_ISP and DO_DISABLE_ISP_CLAMP flags while flashing CPLD for Intruder cards.(SCGCQ01452026) - Fail to Set SSDSmartErEnabled to TRUE when copyback is disabled.(SCGCQ01403999) - PL 14.00.07.00 intgration to MR 6.14 intruder..(SCGCQ01401110) - Integrate phase 14 Intruder PL - 14.00.06.00 with MR 6.14.(SCGCQ01386225) - Add "Incompatible with Profile" event.(SCGCQ01289924) - Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848) -.(SCGCQ01389581) - Add Test Link Diagnostic API.(SCGCQ01436268) - Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048) - Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245) - Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149) - Add support for API fields to report SED type of PD.(SCGCQ01587230) - Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520) - NVDATA parameter to OPAL SED.(SCGCQ01614689) - Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350) - Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135) - Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234) - API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667) - Request to enable JBOD for Rambler PNP ID.(SCGCQ01727448) - Reverted the DDR tuning values.(SCGCQ01625968) - Porting the changes of NVRAM_Struct from MesaVerde stream to 6.14.(SCGCQ01563144) - Enhance Messaging Unit error ISR to dump debug information of virtual functions having error.(SCGCQ01553249) - CacheCade: IO performance need to be improved for WB SVD and WB CCVD combination for specific PnP ID.(SCGCQ01472061) - FW breaks into montaks with pinned cache and foreign configuration.(SCGCQ01403814) - Boot message string change for BOOT_MSG_CACHE_DISCARD.(SCGCQ01394348) - Block OCR after Clearing NVRAM.(SCGCQ01386919) - PL 14.00.05.00 Integration with Invader MR 6.14.(SCGCQ01384265) - Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045) FW to fail back host command for the wrong value.(SCGCQ01575960) - Setting DDR flag for ROMB design having new DDR for an OEM.(SCGCQ01466802) Version 24.21.0-0016 - Moderate Impact/Low Probability of Occurrence -------------------- PACKAGE: 24.21.0-0016 BIOS: 6.36.00.1_4.19.08.00_0x06180202 UEFI Driver: 0x06180202 HII: 03.25.05.03 NVDT: 3.1705.00-0005 MR FW: 4.680.00-8258 Fixes: - MR 6.13: Blocked Spin down Pass thru command for configured drives.(SCGCQ01201958) - In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01213915) - Setting all the ldtoTgtId with 0xff beyond 240 entries.(SCGCQ01215003) - (SCGCQ01219438) - MR_EVT_PD_ERROR_STATS events are logged when drive is moved to REBUILD/UNCONFIGURED BAD/ONLINE/OFFLINE. Also correct DCMD(SCGCQ01223284) - FW crashes when FW update(OFU) is done with faluty onfi(SCGCQ01227115) - Coverity issues:fixed the coverity defects.(SCGCQ01230560) - Update the MAXTransferLength properly for Driver enabled 1MB support feature(SCGCQ01232275) - Assertion failure in ../../dm/mpt2/mptrec.c at line 3139, while performing cable pull/push operation.(SCGCQ01235505) - corrected the span index(SCGCQ01236287) - Coverity issue 15748 and 17765(SCGCQ01241568) - Drive Strength values are incorrect for last 8 phys of Red Brick Controller(SCGCQ01241680) - Change Slew Rate on dual rank RedBrick Boards to fix ECC Errors.(SCGCQ01242817) - Cache Data lost if power loss happens during descriptor preparation.(SCGCQ01253076) - 'C0:mr_wakeup: mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors.(SCGCQ01256120) - Assertion failure in ../../raid/2108vI2o.c at line 2398 on flashing firmware(SCGCQ01258563) - Dev defect to address action items identified during Ventura(SCGCQ01260609) - Dev defect to handle HW action items identified during Intruder(SCGCQ01261213) - Cache data Lost when Term Log is set to "on"(SCGCQ01261426) - 6.13 ONFI_PORT: If power loss occurs after OCR, FW might lose tty log.(SCGCQ01262834) - 6.13_ONFI_PORT: Program the erase and wait count values during ONFI Initialization.(SCGCQ01262883) - 6.13 ONFI PORT :Set bit 0 in global Interrupt Register so that host will receive an interrupt.(SCGCQ01262884) - Flash File System Reads fail after system reset.(SCGCQ01267220) - FW does not remember user induced bad blocks across boots.(SCGCQ01267700) - MR 6.13(SCGCQ01268066) - Unable to access device PD (SSD)(SCGCQ01268412) - MR_6.13:FW flash pack (SCGCQ01273216) - Cache Restore fails if supercap is removed while cache offload is in Progress.(SCGCQ01274494) - Unable to set termlog on/off from storcli intermittently on Intruder Armstrong board.(SCGCQ01278512) - Storcli Failed to create single PD R0 from UGood drive which has replaced a UBAD foreign drive(SCGCQ01282181) - Intruder : After Termlog Toggling with power cycle, result to ERROR: Dirty disk cache data has been lost(SCGCQ01282319) - Modify Read Eye Training Algorithm to make it spec compliant.(SCGCQ01283719) - High DB and Log write(SCGCQ01285311) - Coverity reported an uninitialized variable(SCGCQ01285595) - OS hung and iMR FW reset when do delete and create VD from previous powersave PD (Spindowned)(SCGCQ01287286) - Reboot the system with 240 R0 Volumes and changing the mode(SCGCQ01288297) - PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01288781) - erase types and startSecureEraseNonSED is set accordingly(SCGCQ01289147) - Modify NVDATA boot message to rename 'NVDATA image' to 'firmware image'(SCGCQ01290201) - Cache data lost event seen for WT vds(SCGCQ01313607) - Kill adapater observed while running IO's on 240 Volumes(SCGCQ01313950) - Coverity: Fixing Coverity defect 16148(SCGCQ01316152) - Fixing the coverity raised issue(SCGCQ01318465) - Coverity issue 19341(SCGCQ01319291) - HW workaround implementation for SCGCQ00830272 and SCGCQ01048567(SCGCQ01323607) - auto config is not happening in some cases after issuing storcli /cx set autopdcache=r0(SCGCQ01323848) - MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations(SCGCQ01332706) - MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address(SCGCQ01332947) - ntruder: Fix the Intruder Boot Block compilation and warning issue.(SCGCQ01334292) - Imr Invader FW crashes while upgrading from Pkg 24.18.0(SCGCQ01342601) - No amber LED when a configured disk is removed(SCGCQ01343017) - Controller fails to boot up when migrated from 6.13 to 6.14 FW for Specific OEM(SCGCQ01348114) - Value defined for the DDR turning parameter DP_IO_VREF_1_2 is wrong for invader boards(SCGCQ01350295) - MR_INVADER_WORKAROUND_PCIE_IGNORE_REPLY_PARITY_ERROR macro definition missing(SCGCQ01351483) - Intruder 4G DDR tuning value has to be changed in MR FW.(SCGCQ01368845) - Lenovo Sebastian Fatal Firmware error when connecting to straight without Group ID support.(SCGCQ01204592) - FW does not fail unsupported erase type for a PD(SCGCQ01221549) - Allow Cyrpto erase on non(SCGCQ01222318) - Fix coverity reported issue(SCGCQ01227079) - FW is not updating EPDs list exposed to host after drives removal event is posted which is causing dev nodes are not getting deleted on drive removal(SCGCQ01230441) - Diagnostics report of iMR Invader contains information about R6 and R60 is set to 0(SCGCQ01235661) - Enable MR_DCMD_PD_ERROR_STATS and the event MR_EVT_PD_ERROR_STATS only for direct attached drives(SCGCQ01237252) - DATA TLB ERROR, While connecting controller each Port to Back(SCGCQ01252111) - MR 6.13.1Alpha:Probable Drive/cable issue Event not printed in firmwarelogs on triggering drive/cable error when connected BP(SCGCQ01256005) - Handling of DCR errors in MSS core(SCGCQ01263110) - Controller does not boot up while performing cache offload .(SCGCQ01278480) - Controller cache discarded due to memory/battery problem(SCGCQ01280181) - Perf(SCGCQ01283507) - Code review: turn off the onfi when bbu is bad(SCGCQ01297565) - Coverity issues 19244, 19245, 19246 and 19248(SCGCQ01299214) - MR 6.14 Intruder(Vail): Intruder Controller hangs in primary core on reboot in Dell Power Edge T620 server.(SCGCQ01299482) - Fix coverity issue 19253 Structurally dead code in checkCacheOffloadStatus, raid/1078init.c(SCGCQ01300678) - coverity defects fixed(SCGCQ01300689) - To fix coverity issue 17759(SCGCQ01317039) - Found invalid event(SCGCQ01347858) - Placement of an image checkword at data area of NOR flash leads to controller crash(SCGCQ01375071) - (SCGCQ01227044) - FC: 0 CS: 0 offload meta signature not valid, ffffffff observed in FW logs on a system restart.(SCGCQ01299424) - MR 6.14 (SCGCQ01300667) - Coverity issue 15356(SCGCQ01301658) - update the boundary values in UpdateFeatureSetValues()(SCGCQ01209605) - FW hang finaly leading to kill adatper with inBox driver(SCGCQ01250342) - MR7.1_NVMe: After foreign import of 64 R0 VDs, operating system unable to discover the VDs(SCGCQ01229929 Port Of SCGCQ01209394) - FW crashes when FW update(OFU) is done with faluty onfi(SCGCQ01235056 Port Of SCGCQ01227115) - Server (Purley): Controller (16i) (SCGCQ01235753 Port Of SCGCQ01200311) - In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01237142 Port Of SCGCQ01213915) - Storcli failed to stop drives LED locating with a range(SCGCQ01241870 Port Of SCGCQ01051728) - MR7.1_NVMe: After foreign import of 64 R0 VDs, operating system unable to discover the VDs(SCGCQ01242766 Port Of SCGCQ01209394) - unable to encrypt disk when using no pass(SCGCQ01245596 Port Of SCGCQ01144752) - Offline Marked DG (RAID0) appearing in RHEL 7 install(SCGCQ01245782 Port Of SCGCQ00995384) - SAS2208 card reset in DataCenter due to unknown reason(SCGCQ01247264 Port Of SCGCQ01240574) - RDM in Use(SCGCQ01255837) - ONFI: To properly handle the OCR case with RESET Status Register.(SCGCQ01259337 Port Of SCGCQ00665475) - ONFI BBLIST:ONFI BadBlocks: COL disarmed, VDs remain in WB mode, no Administrative Messages to bad flash part.(SCGCQ01260470 Port Of SCGCQ01235856) - Firmware halts upon changing controller personality to JBOD mode with MCTP enabled(SCGCQ01260889 Port Of SCGCQ01252243) - Infinite loop in onfiSyncModeEnter(SCGCQ01260995 Port Of SCGCQ00329024) - FW crashes when setting fwtermlog bbu=on to a card with bad NAND flash(SCGCQ01261425 Port Of SCGCQ01129530) - Insertion of the boot messages and the evets for montoring the ONFI backup capacity.(SCGCQ01263212 Port Of SCGCQ00433463) - 'C0:mr_wakeup: mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors.(SCGCQ01263800 Port Of SCGCQ01256120) - Handling of DCR errors in MSS core(SCGCQ01263859 Port Of SCGCQ01263110) - Invalid date for next learn cycle is set due to invalid date from OEM server (STF: Next learn time is 1970(SCGCQ01264476 Port Of SCGCQ01152321) - GetAllLDAllowedOperation call in Storelib is not returning Allowed operations when some LDs are deleted(SCGCQ01265445 Port Of SCGCQ01250559) - FD33xD issues in VMWare(SCGCQ01266300 Port Of SCGCQ01203008) - In RAID personality, MR_DCMD_CFG_AUTOCFG DCMD is disabled in non(SCGCQ01274496 Port Of SCGCQ01213915) - MR_6.13:FW flash pack (SCGCQ01280567 Port Of SCGCQ01273216) - unable to encrypt disk when using no pass(SCGCQ01287082 Port Of SCGCQ01144752) - Controller cache discarded due to memory/battery problem(SCGCQ01288848 Port Of SCGCQ01280181) - RAID10 VD goes to failed state after performing RLM(SCGCQ01289123 Port Of SCGCQ01277951) - IN FAILED ARRAY bit is not being set when a VD is cleared(SCGCQ01289194 Port Of SCGCQ01137359) - Storcli Failed to create single PD R0 from UGood drive which has replaced a UBAD foreign drive(SCGCQ01290418 Port Of SCGCQ01282181) - RAID10 VD goes to failed state after performing RLM(SCGCQ01291340 Port Of SCGCQ01277951) - Controller cache discarded due to memory/battery problem(SCGCQ01291492 Port Of SCGCQ01280181) - Cannot stop patrol read on PD with medium errors by the stop cmd(SCGCQ01294884 Port Of SCGCQ01063103) - Perf(SCGCQ01297497 Port Of SCGCQ01283507) - Code review: turn off the onfi when bbu is bad(SCGCQ01297666 Port Of SCGCQ01297565) - Code review: turn off the onfi when bbu is bad(SCGCQ01299260 Port Of SCGCQ01297565) - Perf(SCGCQ01300759 Port Of SCGCQ01283507) - PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01304919 Port Of SCGCQ01288781) - Firmware:(SCGCQ01306491 Port Of SCGCQ01258853) - 6.14 : To fix IOPATH overflow during linking(SCGCQ01311731 Port Of SCGCQ01311464) - Unable to access device PD (SSD)(SCGCQ01321307 Port Of SCGCQ01268412) - OS hung and iMR FW reset when do delete and create VD from previous powersave PD (Spindowned)(SCGCQ01326069 Port Of SCGCQ01287286) - HW workaround implementation for SCGCQ00830272 and SCGCQ01048567(SCGCQ01326394 Port Of SCGCQ01323607) - B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B)(SCGCQ01331892 Port Of SCGCQ01271186) - B200M4 (Carmel/ 3108 iMR): driver crashed after FW update via UCSM (UCSM bundle 2.2(8fS2)A/B to 3.1(2.163)A/B)(SCGCQ01332726 Port Of SCGCQ01271186) - MR 6.14 Intruder(Vail): Intruder Controller hangs in primary core on reboot in Dell Power Edge T620 server.(SCGCQ01334334 Port Of SCGCQ01299482) - MR_6.14: Intruder PCI Trapping ISR incorrect logic for config trap address(SCGCQ01334365 Port Of SCGCQ01332947) - MR 6.14 Beta: MonTask: line 245 in file ../../raid/1078int.c while running reboot test with background operations(SCGCQ01339330 Port Of SCGCQ01332706) - Cache data lost event seen for WT vds(SCGCQ01349420 Port Of SCGCQ01313607) - Kill adapater observed while running IO's on 240 Volumes(SCGCQ01350347 Port Of SCGCQ01313950) - No amber LED when a configured disk is removed(SCGCQ01350771 Port Of SCGCQ01343017) - Firmware hits montask while reconstruction when drive is pulled out(SCGCQ01351442 Port Of SCGCQ01260340) - MR 6.13: Blocked Spin down Pass thru command for configured drives.(SCGCQ01351559 Port Of SCGCQ01201958) - IOMMU fault at address 0x80360000(SCGCQ01356192 Port Of SCGCQ01279547) - LSA hangs when user try to change drive security key.(SCGCQ01367331 Port Of SCGCQ01342655) - Invalid date for next learn cycle is set due to invalid date from OEM server (STF: Next learn time is 1970(SCGCQ01241869 Port Of SCGCQ01152321) - MR6.12 NVRAM Overflow (SCGCQ01248969 Port Of SCGCQ01230749) - FD33xD issues in VMWare(SCGCQ01261095 Port Of SCGCQ01203008) - FD33xD issues in VMWare(SCGCQ01263759 Port Of SCGCQ01203008) - Configuration lost and system crashed on having a stale configuration connected(SCGCQ01273187 Port Of SCGCQ01170701) - PL Fault 0000601e observed while running multipath on/off script in JBOD mode.(SCGCQ01304921 Port Of SCGCQ01288781) - FC: 0 CS: 0 offload meta signature not valid, ffffffff observed in FW logs on a system restart.(SCGCQ01351052 Port Of SCGCQ01299424) - Controller fails to boot up when migrated from 6.13 to 6.14 FW for Specific OEM(SCGCQ01351614) - SAS2208 card reset in DataCenter due to unknown reason(SCGCQ01311439 Port Of SCGCQ01240574) - Drive Strength values are incorrect for last 8 phys of Red Brick Controller(SCGCQ01247082 Port Of SCGCQ01241680) - Firmware hits montask while reconstruction when drive is pulled out(SCGCQ01282285 Port Of SCGCQ01260340) - Code review: turn off the onfi when bbu is bad(SCGCQ01299219 Port Of SCGCQ01297565) - Controller does not boot up while performing cache offload .(SCGCQ01288845 Port Of SCGCQ01278480) Enhancements: - New fault code for routine synchronous reset(SCGCQ01264142) - Vail FW not responding to PWR_REQ in time. Request to up the number of TURs sent before timing out drive.(SCGCQ01373161) - Disable OOB communication via I2C(SCGCQ01369359) - Integrate Intruder PL 14.00.04.00 with MR 6.14(SCGCQ01341925) - PL phase 13.0007.00 integration with MR 6.13(SCGCQ01334112) - PL integration(SCGCQ01330898) - Integrate PL phase 14.00.02.00 with MR 6.14(SCGCQ01307233) - Integrate 13.00.06.00 PL to MR 6.13(SCGCQ01304141) - PL integration 12.00.10.00 with MR 6.12(SCGCQ01276465) - Integrated PL 12.0.9.0 with MR 6.12(SCGCQ01268897) - Shift IOPATH code by 4 cache lines to workaround intruder performance issue.(SCGCQ01262698) - PR State Machine Clean up during Patrol Read/Check Consistency Conflicts(SCGCQ01260431) - Integrate intruder PL 13.00.04.00 (SCGCQ01237533)(SCGCQ01238286) - Integrate PL 13.00.04.00 to MR_FW_SAS3_6.13_4G_DDR(SCGCQ01238126) - Open up MR_DCMD_CFG_AUTOCFG for iMR for GET operation(SCGCQ01228949) - Customer requesting digitally signed FW packages on their Intruder controller(SCGCQ01215397) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028) - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005) - MPI 2.6: Device side PCIe SRNS flag(SCGCQ01276256) - MPI 2.6: Add new firmware download type (CPLD IMAGE)(SCGCQ01305760) - IN FAILED ARRAY bit is not being set when a VD is cleared(SCGCQ01137359) - Integrate Intruder PL 13.00.05.00 (RO SCGCQ01263844)(SCGCQ01265401) - Add additional sense data to firmware tracker list(SCGCQ01254954) - Method for determining bad ONFI flash via Storcli & SNMP trap upon NAND flash failure for Aspen and Vail (Invader and Intrude(SCGCQ01219862) - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267) - MPI 2.6: Add Aero PCI Device IDs(SCGCQ01373008) - Isolating faulty cable issue from bad drive issue(SCGCQ01215270) - PL integration(SCGCQ01268896) Version 24.18.0-0046-1 - Moderate Impact/Low Probability of Occurrence -------------------- BIOS: 6.34.01.0_4.19.08.00_0x06160201 UEFI Driver: 06160201 HII: E3.23.06.04 NVDT: 3.1611.00-0012 MR FW: 4.670.00-8194 Package: 24.18.0-0046 - Removed support update via ThinkSystem XClarity Control (XCC) web GUI and Lenovo XClarity Essentials OneCLI -imm option Version 24.18.0-0046 - New Function Only/No fixes -------------------- BIOS: 6.34.01.0_4.19.08.00_0x06160201 UEFI Driver: 06160201 HII: E3.23.06.04 NVDT: 3.1611.00-0012 MR FW: 4.670.00-8194
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
ThinkSystem RAID and ServeRAID M Series SAS/SATA Controller Driver for Linux This product supports [SLES 12.5,12.4,12.3] Adapters Supported: ThinkSystem RAID 530-8i PCIe 12Gb Adapter (7Y37A01082) ThinkSystem RAID 530-4i Flex Adapter (7M17A03932) ThinkSystem RAID 530-4i Flex Adapter (7M27A03918) ThinkSystem RAID 530-8i Dense Adapter (SD530 RAID) ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727) ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter (7Y37A01083) ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter (4Y37A09722) ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (7Y37A01084) ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085) ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086) ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (7Y37A01087) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M17A03933) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M27A03917) ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721) ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728 ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735 ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A78836 NOTE TO SERVICE - Reference RETAIN #N/A 07.727.03.00- Moderate Impact/Low Probability of Occurrence -------------------- MR 7.27 Defects: -OS support list file update.(DCSG01539093) -Fixed driver compilation for CONFIG_COMPAT.(DCSG01220245) -Kernel with no compat_ioctl support leads to compilation failure.(DCSG01237312) -IOs on un-intended virtual drive fails when a different virtual drive is pulled out.(DCSG01417063) -Linux Driver ReadMe Cleanup.(DCSG01536648) -irq_free call trace seen upon driver shutdown.(DCSG01531523) -oe20.03 LTS-SP1 driver binary RPM is missing from the latest RO.(DCSG01269925) -Remove RHEL 9.0 RT kernel binary.(DCSG01238725) EnhancementRequests: -RHEL8.7 GA OS Mainline kernel and RT kernel support.(DCSG01364506) -MR7.27: SLES15SP5 OS support.(DCSG01451936) -Added support for RHEL8.6 GA.(DCSG01215194) -SLES15 SP4: Update OS support list file.(DCSG01234735) -Created a Fusion OS 22_22.0.1 build kit to generate driver binaries.(DCSG01232277) -Added support for Ubuntu 22.04 LTS.(DCSG01203110) -RHEL9.0 GA OS Mainline and RT kernel support.(DCSG01364140) -MR7.26: RHEL9.2 GA Mainline and RT kernel OS support.(DCSG01438455) -Add megaraid_sas driver support for Fusion OS 22_22.0.1.(DCSG01324301) -SLES15SP4 GM OS RT kernel support (Build kit support).(DCSG01365053) -MR7.26: RHEL8.8 GA OS mainline and RT kernel support.(DCSG01438447) -Added Capability Bit for Driver Dump Mode Status to MFI_CAPABILITIES.(DCSG01321222) -RHEL9.1 GA OS Mainline kernel and RT kernel support.(DCSG01364319) -SLES15SP4 GM OS RT kernel support.(DCSG01365021) 07.722.02.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.22 Defects: -Megaraid 7.22: RHEL 9.0 has RT kernel binary, as per PR support on 7.23 onwards..(DCSG01238725) Enhancements: -SLES15 SP4 OS driver support.(DCSG01132146) 07.720.05.00 - Moderate Impact/Low Probability of Occurrence -------------------- Package add new OS 15.4 07.720.04.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.20 Defects: -Disable "shared host_tagset" feature.(DCSG01107335 (Port Of Defect DCSG01111551)) -Fix race condition due to concurrent access of ISR from multiple contexts..(DCSG01032071 (Port Of Defect DCSG01038495)) -Use managed vectors API/s for IRQ allocation and affinity for >=5.0 and >=RHEL8.2 kernels..(DCSG01060650 (Port Of Defect DCSG01065135)) -megaraid_sas returns DID_NO_CONNECT for an existing LUN.(DCSG01090218 (Port Of Defect DCSG01091958)) EnhancementRequests: -DCSG01082446 07.719.03.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.19 Defects: -Fix race condition due to concurrent access of ISR from multiple contexts.(DCSG01032071) 07.717.02.00-2 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.17 Defects: -One VD deletion leads to IO blocked to different VD forever.(DCSG00948232 (Port Of Defect DCSG00951388)) EnhancementRequests: -MR7.17: Driver module signing for RHEL and SUSE.(DCSG00418428) -Block the IO on Deleted VDs derived from Raid Map update.(DCSG00342297) -MR7.17: Improve error handling at multiple places in driver.(DCSG00368931) -MR7.16: Add RHEL7.9 GA support.(DCSG00382600) -MR7.17: RHEL8.3 GA support.(DCSG00418201) -Xenserver 8.2 LTSR support.(DCSG00361050) 07.715.03.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.15 Defects: -MR7.15: silence warnings of IO request frames memory allocation failure.(DCSG00243681) -MR_7.15: 7.15 ROP os readme file accordance with os support list.(DCSG00249459) -[9361-8i + MR6.14] (Internal BRCM) Controller Run into Fatal Error Stop at Critical State when run fio to reproduce issue in(DCSG00079487).(DCSG00129711) -Linux_Drv_BST: Update AutoBST script to stop Chaos IOs before deleting FS and other fixes.(DCSG00134557) -MR 7.14 Linux driver Read-Me file needs some corrections..(DCSG00070005) -MR_7.14: Linux driver OS_Support_list needs an update..(DCSG00115285) -MR7.14: Driver is using undefined macro MFI_BIG_ENDIAN for isEPD bit field.(DCSG00137916) -Limit max device queue_depth to controller queue_depth.(DCSG00059412 (Port Of Defect DCSG00082448)) EnhancementRequests: -Modify bst_linux.py script to load RHEL7.7 binary.(DCSG00130098) -MR7.15: RHEL8.2 GA OS Support.(DCSG00167212) -update dkms.conf file for UBUNTU20.04.(DCSG00080086) -Remove NVME hole detection algorithm.(DCSG00076490) -Add RHEL7.8 GA Support.(DCSG00129747) -MR7.15: SLES15SP2 GM Support.(DCSG00259047) -Citrix Hypervisor 8.1 GA support.(DCSG00062914) -BST scripts optimization.(DCSG00073579) -Source RPM support for RHEL8.2 and UBUNTU20.04 pre-GA OS.(DCSG00079575 (Port Of EnhancementRequest DCSG00081340)) 07.713.02.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.13 Defects: -Use RAID map for Tape devices even if FW supports JBOD sequence map.(DCSG00055167) -Add NULL check for RAID map pointer in non RW LDIO path and fix coverity reported issues.(DCSG00033292) -Code review found defect.(DCSG00058719) -Improper error print message for non-secure AERO adapters.(DCSG00045253 (Port Of Defect DCSG00054761) EnhancementRequests: -Unique names to MSIx vectors.(DCSG00025922) -Call kernel panic upon receive of IO with holes for NVME devices.(DCSG00049785) -Add binary support for RHEL8.1.(DCSG00049836) -MR7.13 : SLES12-SP5 GM Support.(DCSG00055090) -Source RPMs shall be signed with GPG public-private key.(DCSG00056767) -Source RPMs shall be signed with GPG public-private key.(DCSG00054345) -Add driver support for "scsi_status" propagation to application.(DCSG00041807) -MR Linux Driver 7.13 : Driver needs to issue all NonRW IOs to SES/vSES devices as LDIOs.(DCSG00041449) -Use Block layer API to check SCSI device in-flight IO request.(DCSG00057168) 07.712.02.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.12 Defects: -Remove incorrect print of Performance mode.(DCSG00002462) -Improper error print message for non-secure AERO adapters.(DCSG00045253) -MR7.11 Linux: Controller hangs on the second OCR.(DCSG00012579 (Port Of Defect DCSG00016290) EnhancementRequests: -Update queue_depth of sas and NVMe device.(DCSG00007172) -Port upstream code to MR7.12 in-house code.(DCSG00005496) -Remove CPU arch check to decide performance mode and rework PCI link speed detection logic.(DCSG00002646) -Add transition_to_ready retry logic in resume path.(DCSG00008028) -RHEL 7.7 Support for MR 7.12.(DCSG00020730) -(DCSG00012782) -Remove code for older unsupported kernels.(DCSG00002458) -.(DCSG00002460) -(DCSG00017314) -.(Change sdev queue depth max vs optimal) 07.710.06.00 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.10 Defects (20) - Add retpoline support in source rpm and fix compilation error in sles15sp1 (SCGCQ02079110) - (Supported (Sea((SA(S38xx) PCI IDs. (SCGCQ01942752) - MR7.10: Driver logs wrong message about adapter's DMA mask (SCGCQ02012089) - Addressed few code review defects/comments on hybrid interrupts implementation. (SCGCQ02057600) - Remove support for (Sea(38xx) PCI IDs in MR driver (SCGCQ01913282) - MR_7.9: Linux driver fails to reboot the system when controller is in dead. (SCGCQ01936787) - Fix deadlock in few DCMDs timeout path due to re-acquiring of "reset_mutex" lock (SCGCQ02044603) - (Set VirtualDiskTgtId and devHandle appropriately when JBOD seuqence map is supported by firmware but disabled at driver devel (SCGCQ02080583) - MR7.9: Restrict hardware workaround for PCI register read retries for Aero/(Sea PCI IDs Only (SCGCQ01977849) - MR7.9, Linux driver: On PowerPC, calling disable_irq_nosync from IRQ context does not work as expected (SCGCQ01984754) - MR7.10_ARM:Assertion failure seen in firmware during boot on cavium ARM server (SCGCQ02035288) - Fixed PCI link speed detection and modified few printk debug levels (SCGCQ02102444) - Unwanted messages seen during source rpm/dpkg installation on Ubuntu (SCGCQ01958026) - Corrected opcode of MFI_CMD_TOOLBOX (SCGCQ02033111) - MR7.10: (SLE(S12 (SP4 driver module need to be compiled with "extern" retpoline flags (SCGCQ02034399) - Dev Linux B(ST script updates to (SAL-1.1902.1.3 (SCGCQ02075522) - MR7.9: Aero perf improvement - Change high IOPs reply queue count to 8 and reply batch count to 16 (SCGCQ01977946) - MR_7.10: Citrix Xenserver Readme file os support should be updated as per os matrix policy. (SCGCQ02115720) - Removed few debug counters from IO path (SCGCQ01942753) - Fixed compilation warnings due to reading non-atomic variable-"device_busy" using atomic_read API for older kernels(<3.17). (SCGCQ01965596) - Enhancement to add support for HO(ST_DEVICE_LI(ST DCMD in Linux driver(SCGCQ02051854 port of SCGCQ02016716) - Fix deadlock in few DCMDs timeout path due to re-acquiring of "reset_mutex" lock(SCGCQ02056151 port of SCGCQ02044603) EnhancementRequests (19) - Added Aero support (SCGCQ01889127) - (Support added for High IOPs Reply queues(reply queues with interrupt coalescing ON) to improve Aero performance (SCGCQ01890975) - MR7.9: Add O(S (Support for RHEL 7.6 (SCGCQ01957415) - MR Aero: Driver should enable PCIe ExtTags (SCGCQ02016780) - Add support for Marlin(device ID- 0xd3) PCI ID. (SCGCQ01889122) - If any fusion register read returns all zeroes, driver will retry reading same register upto 3 times. (SCGCQ01965468) - Removed support for UEK kernels and (SLE(S12 (SP1 (SCGCQ02016741) - MR7.8 : Add rhel7.6 and sles12sp4 support (SCGCQ02069610) - (Support for multiple performance modes for Aero. (SCGCQ02072557) - (Support hybrid set of managed and non-managed vectors for 5.0 and onwards kernels (SCGCQ02018287) - MR7.10: Modify RPM spec file to be compatible with RHEL8 RPM framework (SCGCQ02011954) - MR7.8 support for rhel8 and sles15sp1. (SCGCQ02063925) - MR 7.9: (SLE(S12 (SP4 O(S (Support (SCGCQ01940318) - Added driver support for PCI lane margining passthrough commands (SCGCQ01943619) - MR7.9: Add O(S (Support for OEL 7.6 (SCGCQ01966563) - (Supported DKM(S based source Deb/RPM for Ubuntu (SCGCQ02012043) - Driver should not issue fastpath IO to Region Lock Bypass queue. (SCGCQ02018278) - Use 32 bit atomic descriptor for Aero if firmware supports it. (SCGCQ01965225) - MR7.9: (Set 63-bit DMA mask in MR Linux driver (SCGCQ01981597) 07.708.05.00-1 - Moderate Impact/Low Probability of Occurrence --------------------- MR 7.8 defects: - FW flash is not needed for driver.(SCGCQ01593539) - MR_7.8:Ubuntu 18.04 OS package description is mentioned as SAS 2.0.(SCGCQ01826712) - MR7.8: Driver compilation fails on latest upstream kernel(>= v4.17), due to changes in "queue_flag_set_unlocked" API.(SCGCQ01821588) - MR7.8: Global SMP affinity setting is disabled incorrectly by driver under certain conditions.(SCGCQ01822883) - MR7.8: Disable WRITE SAME commands from host for zeroout block ranges operations.(SCGCQ01823902) - Alpha Release Version 07.708.03.00-1 - MR_LINUX_DRIVER_7.8 (38) - MR7.8: Linux driver compilation fails on PPC (ppc64le) server(SCGCQ01861892) - MR7.8: During probe, locking PCI config space while doing adp_reset is applicable to all fusion based controllers.(SCGCQ01841413) - MR7.8: Capture known OS limitations in Driver readme.(SCGCQ01888783) - Fix deadlock in few DCMDs timeout path due to re-acquiring of "reset_mutex" lock.(SCGCQ02044603) - Driver BST test cases need modification.(SCGCQ01664978) - Driver fires a DCMD to incorrect Target ID’s to obtain Maximum Data transfer size (MDTS) of NVME devices.(SCGCQ01786657 port of SCGCQ01760644) (EnhancementRequest - Update Linux Driver BST scripts and wrapper.(SCGCQ01529349) - MR7.8: Enable irq poll in Linux driver to avoid CPU hard and soft lockups.(SCGCQ01571355) - Improvement in driver debugging.(SCGCQ01753524) - Retpoline compilation support for MR Linux drivers for Spectre_v2 vulnerability.(SCGCQ01763140) - MR7.8: Lock access to controller's PCI config space from user space while Diag reset operation is going on.(SCGCQ01824443) - MR7.8: Add RHEL 6.10 Support.(SCGCQ01838376) - MR7.8: Add SLES 15 OS Support.(SCGCQ01854853) - MR7.8: Add Oracle Linux 6.10 OS Support.(SCGCQ01857765) - MR7.8 : Add rhel7.6 and sles12sp4 support.(SCGCQ02069610) - MR7.8 support for rhel8 and sles15sp1.(SCGCQ02063925) 07.707.04.00-1 - Moderate Impact/Low Probability of Occurrence -------------------------- MR 7.7 (new) Defects: - Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01514452) - FW flash is not needed for driver.(SCGCQ01593539) - Modified driver prints to dump relevant FW provided values(part of controller info structure) in syslog.(SCGCQ01626839) - Merge upstream patch "Convert timers to use timer_setup" to in-house and support timer_setup API in 4.15 kernels.(SCGCQ01586787) - MR7.7: scsi_dma_map() is called twice in IO path.(SCGCQ01619432) - Driver is incorrectly deciding combined reply queue mode for SAS3.0 controller(SCGCQ01633318) - Updated driver's file- "OS_Support_list_mr7.7.txt" with CMA support enablement and retpoline compliant driver binaries.(SCGCQ01760521) - Renamed scratchpad registers from scratchpad0 , scratchpad1 etc ... in order to align with firmware naming convention.(SCGCQ01440031) -(SCGCQ01664978) - Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01440720 port of SCGCQ01430747) - Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through.(SCGCQ01483730 port of SCGCQ01468189) - XenServer 7.3 OS support- MR 7.6.(SCGCQ01594134 port of SCGCQ01554012) - Divert FastPath IO with Chain frame to Firmware path.(SCGCQ01598186 port of SCGCQ01593175) - expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01475068 port of SCGCQ01019663) - Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through.(SCGCQ01542421 port of SCGCQ01468189) - expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01542422 port of SCGCQ01019663) - After a kill adpater, megasas_wait_for_adapter_operational waits for almost 360seconds before bailing out.(SCGCQ01619441 port of SCGCQ01615239) - Setup IRQs only after Reply descriptors are allocated.(SCGCQ01542423 port of SCGCQ01506133) - MR: Remove trace kernel RPMs from SUSE SLES11 SP4 driver iso images.(SCGCQ01594109 port of SCGCQ01563428) - megasas_get_target_prop failing after OCR completed.(SCGCQ01619439 port of SCGCQ01607430) - NVMe Task Management - Controller Reset Support (MegaRAID).(SCGCQ01592015 port of SCGCQ01545040) - Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443432 port of SCGCQ01439776) - Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01449786 port of SCGCQ01430747) - Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01449816 port of SCGCQ01442784) - Setup IRQs only after Reply descriptors are allocated.(SCGCQ01514459 port of SCGCQ01506133) - Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01523087 port of SCGCQ01514452) - Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01542419 port of SCGCQ01449957) EnhancementRequests (23) - Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01442784) - Few officially unsupported PCI IDs are removed from MR7.7 driver code.(SCGCQ01598587) - XenServer 7.4 OS support - MR 7.7.(SCGCQ01628129) - Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01449957) - Rebase inbox megaraid_sas driver to inhouse to reduce two different code base for maintenance.(SCGCQ01578030) - MR_Aero: Create timer based thread in MR drivers to detect firmware FAULT.(SCGCQ01157766) - Remove UpdateIoMetric and hence adapter level spinlock from IO path(SCGCQ01522127) - Create cpu to msix table for kernel provided PCI_IRQ_AFFINITY (>=4.12 kernel).(SCGCQ01598134) - OS driver support for Oracle Linux 7.5 - MR 7.7.(SCGCQ01586106) - OS Driver Support for Ubuntu 18.04- MR 7.7.(SCGCQ01586128) - Support RHEL7.5 GCA (3.10.0-862.el7.x86_64).(SCGCQ01586135) - Early detection of faulty controller.(SCGCQ01599562) - Change attribution language from Avago to Broadcom and update copyright end year.(SCGCQ01753095) - Offload R5/R6 division to driver.(SCGCQ01513544) - Update Linux Driver BST scripts and wrapper.(SCGCQ01529349) - Marlin support is added to drivers.(SCGCQ01440724) - Remove support for RHEL7.1, OEL7.2 and SLES12.(SCGCQ01449982) - Optimize code around (raid context) in IO path.(SCGCQ01598187) - Removed support of RHEL7.1, SLES12 and OEL7.2.(SCGCQ01600475) - FW OCR Debug Mechanism - triggerSnapDump.(SCGCQ01520447) - Set SLD bit in RAID map when "enableSLDOnAllRWIOs" is enabled.(SCGCQ01715619) - Revert code changes related to iMR performance throttling.(SCGCQ01749962) - Revert changes added in driver to divert FastPath IO with Chain frame.(SCGCQ01752939) Version 07.705.05.00 - Moderate Impact/Low Probability of Occurrence --------------------- Defects: - Driver fires a DCMD to incorrect Target ID’s to obtain Maximum Data transfer size (MDTS) of NVME devices.(SCGCQ01760644) EnhancementRequests: - Compiled megaraid_sas driver binaries with retpoline support to workaround Spectre v2 vulnerabilities.(SCGCQ01790176) Version 07.705.04.00-5 - Moderate Impact/Low Probability of Occurrence Defects (7) - Provided driver workaround to reset __GFP_WAIT flag while allocating IO request frames.(SCGCQ01394892) - Driver will use 64 bit request descriptor for sending IO to Ventura firmware.(SCGCQ01514452) - Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver(SCGCQ01389431) - Fixed few dev found and coverity reported defects(SCGCQ01392652) - Selective stream detection logic in driver(SCGCQ01392643) - During PCI remove, set unload flag after scsi_remove_host is called.(SCGCQ01392656) - update LD map after populate drv_map, increase wait in IOCTL, fix index in error handling, rework in refiring DCMDs.(SCGCQ01415439) - Added support for threaded interrupts.(SCGCQ01615015 port of SCGCQ01498747) - Driver should go through stream detection logic after it's finalized which path(fastpath vs non fastpath) IO will go through(SCGCQ01483730 port of SCGCQ01468189) - Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01455132 port of SCGCQ01430747) - MR: OEL 7.4 and 6.x x86_64 RPMs do not have the correct kernel versions.(SCGCQ01611888 port of SCGCQ01607445) - expose fw_outstanding and drv_outstanding variables to the OS level sys interface.(SCGCQ01475068 port of SCGCQ01019663) - Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01564604 port of SCGCQ01454090) - Added NVME passthru support in MR linux driver.(SCGCQ01424605 port of SCGCQ01407028) - Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01455206 port of SCGCQ01454090) - Added NVME passthru support in MR linux driver.(SCGCQ01455135 port of SCGCQ01407028) - Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443433 port of SCGCQ01439776) - Setup IRQs only after Reply descriptors are allocated.(SCGCQ01514459 port of SCGCQ01506133) - Use pci_{alloc/free}_irq_vectors for >=4.12 kernels.(SCGCQ01449816 port of SCGCQ01449816) - Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01449786 port of SCGCQ01430747) - Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver.(SCGCQ01392672 port of SCGCQ01389431) EnhancementRequests (10) - MR7.4: Add SLES12 SP3 OS support.(SCGCQ01396756) - Added support for RHEL7.4.(SCGCQ01455156) - Added driver support for OEL7.4.(SCGCQ01396747) - Increased JBOD FPIO timeout by 1 sec to workaround hardware bug which causes timeout 1 sec earlier than provided timeout value.(SCGCQ01449957) - Added support for threaded interrupts.(SCGCQ01498747) - MR7.4: OS driver support for RHEL 7.4.(SCGCQ01396738) - Added support for SLES12 SP3.(SCGCQ01455167) - Added driver binary support for Xenserver7.2.(SCGCQ01393249) - Remove support for RHEL7.1, OEL7.2 and SLES12.(SCGCQ01449982) - Removed support for few OS to align with OS support matrix policy.(SCGCQ01393194) Version 7.703.07.00- Moderate Impact/Low Probability of Occurrence --------------------- fixes: - Send sense buffer upper 32bits inside IOC INIT frame.(SCGCQ01315987) - MR: On OEL 6.x/7.x with UEK kernels - megaraid_sas.conf file from the kmod rpm does not match kernel version.(SCGCQ01319368) - pass upper 32 bits of version buffer and system information buffer to FW inside IOC INIT frame.(SCGCQ01326366) - Workaround changes for FW MFA frame pull issue.(SCGCQ01338087) - Log dmesg if IOC INIT fails in IOMMU and RDPQ enabled enviornment for user information only.(SCGCQ01338097) - Validated if any of DMA buffers pool which should be in same 4GB region does not cross 4GB boundary.(SCGCQ01338372) - Memset to zero for MFI command frame for IOC INIT and use lower_32_bits() macro to get lower 32bits of DMA address passed to FW.(SCGCQ01341287) - Removed Crusader ID(device ID- 0x0015) from supported PCI IDs of MR7.2 linux driver.(SCGCQ01350963) - MR7.3: Code review defect - ioc_init_frame not freed during kernel module unload.(SCGCQ01384694) - MR7.2: In megasas_issue_tm() SMID needs to be used for Task abort case only.(SCGCQ01315252) - Incorrect processing of IOCTL frames for SMP/STP commands.(SCGCQ01383823) - Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01298582) - Removed print "Failed from megasas_complete_cmd" from PD CFQ sequence DCMD completion path.(SCGCQ01321565) - Do not switch DMA mask to meet same 4gb requirement. IOMMU does not work well with such DMA mask switch.(SCGCQ01342578) - Allocated MFI frame size and the size of MPT chain frame(Where MFI frame resides for MFI MPT passthru commands) should match.(SCGCQ01342650) - Minimum possible value for module parameter- resetwaittime should be 1 secs instead of 0 secs.(SCGCQ01344137) - Set DMA mask after FW is in READY state in PCI resume path of megaraid_sas driver.(SCGCQ01389431) - MR7.3: Data miscompare found with WB secure VD RAID 1 with LSA sending IOCTLs in parallel.(SCGCQ01378684) - Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01381770 port of SCGCQ01298582) - MR: On OEL 6.x/7.x with UEK kernels - megaraid_sas.conf file from the kmod rpm does not match kernel version.(SCGCQ01320324 port of SCGCQ01319368) - Use IOC_INIT frame once driver has verified IOC_INIT frame allocation was successful.(SCGCQ01455132 port of SCGCQ01430747) - Updated correct supported kernel version of Ubuntu16.04 in driver's document- OS_support_list_mr7.5.txt.(SCGCQ01455206 port of SCGCQ01454090) - Added NVME passthru support in MR linux driver.(SCGCQ01455135 port of SCGCQ01407028) - Updated OEL6_UEK and OEL7_UEK buildkit.(SCGCQ01443433 port of SCGCQ01439776) - Minimum possible value for module parameter- resetwaittime should be 1 secs instead of 0 secs.(SCGCQ01344142 port of SCGCQ01344137) EnhancementRequests: - Added support for 64bit DMA mask for invader.(SCGCQ01294199) - MR7.3: add support for Citrix XenServer 7.1 OS.(SCGCQ01257971) - Send current time to FW during IOC init.(SCGCQ01307072) - Added support for RHEL7.4.(SCGCQ01455156) - MR7.3: add support for OEL 6.9.(SCGCQ01289005) - Added support for threaded interrupts.(SCGCQ01498747) - Added support for 64bit DMA.(SCGCQ01301940) - Added support for SLES12 SP3.(SCGCQ01455167) Version 7.702.06.00- Moderate Impact/Low Probability of Occurrence --------------------- Defects (47) - Reset MPT frame field cmd_completed while retrurning it back to free pool.(SCGCQ01176530) - Optimized R1 FP write code.(SCGCQ01191077) - Before populating driver RAID map copy memset drv_map to zero and ldTgtIdtoLd array to 0xff(SCGCQ01204087) - Initialize stream detection array properly.(SCGCQ01204096) - On SPARC/Big endian host, need to convert peerSMID to little endian to CPU before accessing(SCGCQ01216698) - Fixed coverity reported issues and changed name of few functions.(SCGCQ01219231) - Don't set tm_capable for JBDO when PD CFG SEQ map is not available(SCGCQ01226222) - Remove local defination FALSE/TRUE and use OS provided false/true.(SCGCQ01256130) - Used vmalloc for crash dump buffers and driver's local RAID maps(SCGCQ01270059) - Reduce size of fusion_context allocation during driver load by moving load_balance_info array out, and try vmalloc if kmalloc fails.(SCGCQ01183280) - Flooding of messages- "BRCM: IO does not end on page boundary; sge_len" while running RAW IOs.(SCGCQ01189815) - Fixed data corruption by asking OS not to do merging of IOs to avoid SGE holes(SCGCQ01231229) - Code review defect: create separate function for allocating RAID maps(SCGCQ01282924) - Removed Crusader ID(device ID- 0x0015) from supported PCI IDs of MR7.2 linux driver(SCGCQ01350963) - Updated OS to send page aligned SGEs by calling blk_queue_virt_boundary(SCGCQ01206279) - Use vmalloc followed by memset to zero instead of vzalloc in driver code.(SCGCQ01206316) - MR_ValidateMapInfo issue on bigendian platform (In some case Detect Ghost VDs)(SCGCQ01213952) - Fixed code review defects(SCGCQ01254323) - Removed code inside macros VD_EXT_DEBUG, SPAN_DEBUG and enahnce prints in OCR path(SCGCQ01270056) - FW fault happens as driver wrongly fill numSGE=0.(SCGCQ01274103) - Code optimization and enhanced prints for debugging(SCGCQ01224881) - Remove unsupported PCI Device IDs from the driver code(SCGCQ01234256) - Resolved conflict of PCI device ID-0x0015(SCGCQ01254317) - MR7.2: In megasas_issue_tm() SMID needs to be used for Task abort case only(SCGCQ01315252) - Save interfaceType for each sysPDs inside SCSI device's private data field which will persists until sysPD is removed/deleted.(SCGCQ01216464) - Code Optimization and enhanced prints(SCGCQ01223300) - MR 7.1: Linux OS crash when powering off enclosure during I/O(SCGCQ01229442) - Return pending IOs with status DID_REQUEUE instead of DID_RESET to SCSU layer before doing OCR(SCGCQ01231846) - MR7.2: Port changes from upstream to make in-house MR 7.2 code to be consistent with upstream code(SCGCQ01282321) - Add print for partially copied SCSI IO and fix few endianness issues(SCGCQ01224305) - Linux Driver 07.700.23.00/Getting megaraid_sas prints during startup of OS(SCGCQ01255074) - aen class range check to avoid kernel panic(SCGCQ01256126) - Corrected bitmap macros inside struct RAID_CONTEXT35(SCGCQ01269453) - Set cmd_status inside DCMD/IO/header frame to MFI_STAT_OK to wake up all pended IOCTLs.(SCGCQ01298582) - Fix few dev found issues(SCGCQ01226224) - On OEL SPARC (Big Endian), Linux MR 7.1 driver loading fails to initialize Ventura which has RDPQ support enabled(SCGCQ01229897) - Fixed few code collab defects/comments(SCGCQ01202237) - Remove throttle IOs prints in IO path and add sysfs parameter to reflect number of R1 FP writes(SCGCQ01204099) - Ventura MR-7.0.1 RHEL 7.2 driver: ERR messages when installing driver 7.700.20.00(SCGCQ01222990) - Use do_div() kernel API to do modulo operation of 64 bit dividend and 32bit divisor .(SCGCQ01243263) - megasas_complete_cmd_dpc_fusion() will be called with 1 sec delay inside function megasas_wait_for_outstanding_fusion(SCGCQ01256116) - Allocated MFI frame size and the size of MPT chain frame(Where MFI frame resides for MFI MPT passthru commands) should match(SCGCQ01342650) EnhancementRequests (17) - Big endian architecture is now support for Ventura generation of MR HBA.(SCGCQ01256016) - Fixed the problem of sync_irq not being called when MSI-x are disabled.(SCGCQ01206307) - Port changes from MR7.0 and MR6.13 critical fixes to MR7.1(SCGCQ01167939) - In megasas_build_ldio_fusion, code to set controller CPU affinity can be optimized(SCGCQ01216486) - Set device queue depth same as controller's can_queue for SCSI MQ mode(SCGCQ01271569) - Add SLES 11 32-bit build kit support to Ventura MR.(SCGCQ01214721) - Ported fixes from MR 6.13 to MR 7.1(SCGCQ01222522) - Added support for RHEL7.3(SCGCQ01224300) - Support SPARC/PPC/ARM (Big/Little Endian). Fix Endianess issue in MR Ventura driver.(SCGCQ01183275) - Added DCMD interface to read target properties for SCSI device(VDs and JBODs both)(SCGCQ01220142) - Added KMOD RPM support for OEL7.3 UEK.(SCGCQ01227476) - R1 Write IOPs improvement(SCGCQ01213232) - Extra code for bug in A0 ventura is removed. Optimized Descriptor write as Ventura required 32 bit in major IO Path operation.(SCGCQ01215347) - Remove Crusader device support from driver(SCGCQ01259175) - Don't re-issue Reset on the way back OCR(SCGCQ01215089) - Rework start_vm_build script used for VBAS build and new build infrastructure for DKMS RPMs(SCGCQ01261800) - Version 7.700.26.00- Moderate Impact/Low Probability of Occurrence --------------------- Enhancement: - Added support for ThinkSystem HBA and RAID. Version 6.812.08.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Modified not to send outstanding IOs back to SML with DID_RESET host_byte but return IOs back with host_byte DID_REQUEUE before doing OCR. (SCGCQ01278656 Port Of Defect SCGCQ01231846) Enhancement - Added support for SLES 12.2 Version 6.812.07.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes - Changed timeout value for DCMDs get_bios_data and get_pd_info 180 seconds to keep it aligned with other DCMDs' timeout value. (SCGCQ00884247) - Do not allow MFI frame to be freed from DCMD fire context when already an OCR is in progress. (SCGCQ00879190) - Fixed an issue where driver always worked in non RDPQ mode even the running firmware did not support RDPQ. (SCGCQ00872542) - Moved SCSI layer interaction code out of reset_mutex in AEN thread to prevent deadlock around reset_mutex. (SCGCQ00868731) - Convert supported JBOD count value returned by firmware in CPU format and then use the same value for further validation (SCGCQ00837088) - Fixed an issue where unevenSpan configuration of R1 would not have proper load balancing for FP READ. SCGCQ00646224 - Added timeout value for wait_event. (SCGCQ00249742) - Enabled hostlockless flag of SCSI host for RHEL6 and clones for async IO submission from SCSI mid layer. (SCGCQ00884242) - Fixed an issue where double freeing of MFI frame in case of MFI IO timeout in polled mode could occur. (SCGCQ00837932) - Added synchronization between OCR thread and AEN thread, so that there should not be any PCI write from AEN thread during OCR (SCGCQ00836410) - Added IO timeout value for SCSI management commands for JBOD. (SCGCQ00750452) - Fixed a JBOD performance issue due to incorrect MSI-x index set in request desc. (SCGCQ00619694) - Changed state machine of firmware crash dump collection to prevent file system on VD being set to Read-only mode after ECC error injection. (SCGCQ00608705) - Fixed an issue where incorrect messages such as LSI SAS2.0 were printed for MR driver. (SCGCQ00298201_ - Fixed an issue where the driver sent an incorrect region type "REGION_LOCK_EXCLUSIVE" set to FW for RAID level >=5 - Changed error handling for DCMD failure cases to allow graceful exit for not fatal errors. (SCGCQ00868661) - Free task management frame after dumping the task management reply frame data to ensure that TM reply frame will have valid data returned by firmware. (SCGCQ00860038) - Release reset_mutex inside OCR function, if adapter is already killed to prevent a kernel panic. (SCGCQ00857740) - Increased timeout to 180 seconds for flush cache and shutdown controller DCMDs to prevent kernel panic when DCMDs fired during driver's shutdown. (SCGCQ00841491) - Fixed an issue where traversed LDs at multiple places up to maximum 256 were limited to 64. (SCGCQ00652795) - Fixed an issue where the driver crashed when msix_disable=1 was passed to the boot time parameter. (SCGCQ00383508) - Fixed an issue where kernel panic seen while deleting VD and background IOs running. (SCGCQ00803468) - Fixed an issue where the driver was not sending DCMD- MR_DCMD_CTRL_SET_CRASH_DUMP_PARAMS after OCR. (SCGCQ00601138) - Fixed an issue where the kernel panicked inside PCI subsystem because of IRQs not freed before disabling MSI-X interrupts (SCGCQ00827403) - Disabled SED drive JBOD support. (SCGCQ00751296) - Fixed multiple OCRs triggering hits Exception Core issue (SCGCQ00707592) - Fixed an issue where the firmware faulted due to invalid regionlock Flags set by Driver. (SCGCQ00796461) - Fixed an issue where subsequent reads of state value from hardware resulted different values and could lead to a timeout in and a non working adapter. (SCGCQ00709216) - Fixed an issue where Offline VD caused boot hangs in SLES 11 (SCGCQ00284564) - Disabled SPAN_DEBUG and set get_arm_from_strip to print if firmware supports UnevenSpan. (SCGCQ00365846) - Added check to validate ldcount exposed in firmware RAID map for legacy firmware. If ldcount is more than 64, fail RAID map validation. (SCGCQ00820349) - Fixed an issue where the Linux kernel crashed when AEN and LD Sync commands were issued frequently. (SCGCQ00712031) - Fixed an issue where duplicate disk(s) were seen on controller after loading Linux driver during OS installation, (SCGCQ00568992) - Fixed an issue where kernel panic could occur at driver load time on 3.0 kernels (i.e. SLES11 SP2, SLES11SP3). (SCGCQ00561505) - Changed driver to return SCSI command back to mid layer if the controller has any critical hardware errors. SCGCQ00362023 - Fixed an issue where the driver did not do Load balance for R1 READ due to wrong stats counters. (SCGCQ00677516 Port of Defect - SCGCQ00674872) - Fixed potential duplicate IOCinit frames being fired by VMware5 VF driver during OCR. (SCGCQ00571967 PORT OF SCGCQ00571679) - Fixed OS crash issue on SCSI IO timeout (SCGCQ00631210 PORT OF SCGCQ00625137) -Fixed an issue where the kernel panicked due to MFI/MPT pass-through command timeout and later finished from Interrupt context. (SCGCQ00307867 PORT OF - SCGCQ00302080) - Fixed an issue where megasas_poll_wait_aen was cleared before poll syscall returns causing to lose events (SCGCQ00575192 PORT OF SCGCQ00574787) -Fixed an issue where data corruption observed on JBODs while running IOs with 32k block size. (SCGCQ00530992 PORT OF SCGCQ00523780) - Fixed MPC kernel panic during chassis power cycle if AEN completes and detach is called before event workqueue runs. (SCGCQ00647390 PORT OF SCGCQ00645836) - Fixed an issue where kernel crashed in some cases, where megaraid_sas driver is loaded but controller is not present. (SCGCQ00282968 PORT OF SCGCQ00282067) Enhancements: - Set queue depth for syspD based on interface type (SCGCQ00879700) - Updated module Meta data (module description and module author) with Avago replacing LSI. (SCGCQ00801961) - Set OS provided timeout value for sysPD non read-write IOs (SCGCQ00764795) - Performance tuning for SMP affinity is implemented for distros's which support irq_set_affinity_hint API. (SCGCQ00623697) - Optimized OCR path to enable interrupt and make HBA OPERATIONAL after driver has fired LD_MAP_GET_INFO DCMD. (SCGCQ00768402) - Added module parameter to turn on/off SMP affinity code. (SCGCQ00666706) - Driver will do load balance for N Drive Raid 1 volumes. (SCGCQ00634064) -Functionality in driver is added to differentiate between iMR and MR at firmware initialization time. (SCGCQ00361244) - Uneven Span support added in Driver. (SCGCQ00319104) - Driver code is updated such way that it can work for any block size drive, if the rest of the system has proper support for the same. (SCGCQ00259244) - Implemented online controller reset if controller is not responding at driver load time. (SCGCQ00820389) - Added SCSI residual bytes support to the megaraid_sas Linux driver (SCGCQ00347089) - Use sequence number for JBOD FastPath I/Os to eliminate command block after drive replacement (SCGCQ00806534) - Big endian architecture support added for MR Linux driver (SCGCQ00526911) - Driver support is added for 3108 C0 chip combine reply queue ON (SCGCQ00354586) - Added support 240 VD feature (SCGCQ00622703) - Added Firmware crash dump collection support (SCGCQ00550369) - Added support for large I/O 1MB transfer size (SCGCQ00816313) - Changed the max sg table size to 64. Old setting was 70 (SCGCQ00653992) - Added driver support for task management for Jbod or VD (tmCapable) (SCGCQ00854635) - Added support for SED JBOD in MR Linux driver (SCGCQ00711555) - Changed code to complete IOCtls posted just before a kill adapter so user space applications do not hang. (SCGCQ00759916) Version 6.810.09.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Fixed an issue where deadlock may occur when the Automatic Event Notification thread runs in parallel with error handler thread (SCGCQ00911332, Port of SCGCQ00868731) - Fixed an issue where driver will operated in RDPQ mode regardless of whether firmware has advertised support or not (SCGCQ00872542) - Fixed an issue where system may reset with error "BUG: unable to handle kernel NULL pointer dereference at 00000000000000d0" preceded by error "megasas: target reset FAILED!!" (SCGCQ00875223) - Fixed an issue where driver MFI frames could be freed twice (SCGCQ00879190) - Fixed an issue where some out-of-band commands had different timeouts than others (SCGCQ00884247) - Fixed an issue where performance was lower on async IO submissions from the SCSI mid layer (SCGCQ00884242) - Fixed an issue where a kernel panic may occur if the system is reset or fail to reboot (SCGCQ00859634, Port of SCGCQ00857740) - Fixed an issue where Task Management frames were not being dumped after the Tast Management Reply frame data (SCGCQ00860038) - Fixed an issue where a fatal error may occur when an out-of-band command times out during an Online Controller Reset (SCGCQ00882011, Port of SCGCQ00868661) - Fixed an issue where kernel may hang when many commands are timing out or many Automatic Event Notifications are being processed (SCGCQ00857245) - Fixed an issue where megaraid_sas module was not being included inside initrd/initramfs (SCGCQ00880965) - Fixed an issue where kernel may panic if driver does not setup IRQs for non-MSI-x interrupt mode (SCGCQ00870263, Port of SCGCQ00867873) - Fixed an issue where driver return code is based on command completion rather than command return code (SCGCQ00856103, Port of SCGCQ00856089) - Fixed an issue where Tape drives may not be detected by the Operating System (SCGCQ00914385, Port of SCGCQ00911702) - Fixed an issue where max_sectors per IO request may be set to more than firmware can handle (SCGCQ00917992, Port of SCGCQ00917399) - Fixed an issue where an IERR may occurr on heavy IO with Failover (SCGCQ00864111, Port of SCGCQ00736612) Enhancements: - Enhanced queue depths in driver for physical disks based on interface type (SCGCQ00879700) - Improved naming of internal functions (SCGCQ00866064) - Updated module parameter "rdpq_enable" default to "1" (enable RQPQ mode) (SCGCQ00871565) - Enhanced reply queue to support queue depth greater than 1K (SCGCQ00853521) - Added feature for driver to support Task Management for JBOD and Virtual Drives (SCGCQ00854635) - Added module parameter to disable 1M IO support and set default to enable 1M IO support (SCGCQ00911362) - Enhanced tasklet initialization so it would occur before setting up IRQs (SCGCQ00914393, Port of SCGCQ00911709) - Simplified HB handling for SR-IOV (SCGCQ00864113, Port of SCGCQ00700580) - Enhanced driver to update Online Controller Reset capability when it changes (SCGCQ00914389, Port of SCGCQ00908352) - Added feature to print Critical, Fatal and Dead firmware events into system logs (SCGCQ00868723, SCGCQ00882010, Port of SCGCQ00866176) - Enhanced HB handling to align with behavior on other Operating Systems (SCGCQ00864117, Port of SCGCQ00707323) - Removed excess dead code (SCGCQ00850012) Version 6.808.16.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes: - Fixed an issue where a deadlock may occur around reset_mutex when Automatic Event Notification threads run in parallel with error handlers - (SCGCQ00911332, Port of SCGCQ00868731) - Fixed an issue where scanning of Tape drives does not occur depending on whether the drive state is set to systemPD or not - (SCGCQ00914385, Port of SCGCQ00911702) - Fixed an issue where max_sectors may be set larger than what firmware can support - (SCGCQ00917992, Port of SCGCQ00917399) - Fixed an issue where kernel may panic due to driver not setting up IRQs for non MSI-x interrupt mode - (SCGCQ00870263, Port of SCGCQ00867873) - Fixed an issue where driver may halt firmware due to improper error handling for DCMD failure cases - (SCGCQ00882011, Port of SCGCQ00868661) - Fixed an issue where driver may hang kernel due to deadlock - (SCGCQ00857245) - Fixed an issue where system may crash due to timeout for flushing cache and shutting down controller DCMDs was not long enough - (SCGCQ00841491) - Fixed an issue where deadlock may occur between Online Controller Reset and Automatic Event Notification processing function - (SCGCQ00846933) - Fixed an issue where PCI writes from Automatic Event Notification thread were occurring during Online Controller Reset - (SCGCQ00836410) - Fixed an issue where MFI frames linked list may corrupt due to double-freeing of frame in the case of an MFI IO timeout - (SCGCQ00837932) - Fixed an issue where kernel may panic inside PCI subsystem due to IRQs not freed before disabling MSI-X interrupts - (SCGCQ00827403) - Fixed an issue where ldcount was not validated for non-240VD firmware - (SCGCQ00820349) - Fixed an issue where a command block would occur for JBODs with FastPath IOs after a drive is replaced - (SCGCQ00806534) - Fixed an issue where 1MB IO support was not supported controller-wide - (SCGCQ00816313) Enhancements: - Set DMA alignment to 8 bytes for PI-enabled VDs - (SCGCQ00928796, Port of SCGCQ00928176) - Added a parameter to support disabling 1MB IO support - (SCGCQ00911362) - Added support for printing Critical, Fatal and Dead Firmware events into system logs - (SCGCQ00882010, Port of SCGCQ00866176) - Added support for driver to perform an Online Controller Reset at driver load time if the controller is not responding - (SCGCQ00820389) Version 6.808.14.00 - Moderate Impact/Low Probability of Occurrence --------------------- Fixes - Fixed an issue where controller may reset or "MonTask: line 1276" error will occur with JBOD present (SCGCQ00837088) - Fixed a performance issue on RAID1 with 256k IO size (SCGCQ00674872) - Fixed a performance issue on RAID1 reads with FastPath enabled (SCGCQ00646224) - Fixed an issue where an Online Controller Reset may take an unusually lon time (SCGCQ00420374) - Fixed an issue where a controller firmware crash may not be recognized by driver (SCGCQ00249742) - Fixed an issue where an MFI frame may be freed twice on MFI command timeout (SCGCQ00837932) - Fixed an issue where the firmware may fault in an Automatic Event Notification fires during an Online Controller Reset before the chip is in READY state (SCGCQ00836410) - Fixed an issue where there was no IO timeout value for SCSI management commands for Secure JBOD (SCGCQ00750452) - Fixed a performance issue on SSDs in JBOD mode (SCGCQ00619694) - Fixed an issue where file system on a VD can go to read-only on ECC error detection (SCGCQ00608705) - Fixed an issue where disks may not be found during installation after loading the driver (SCGCQ00299643) - Fixed an issue where a kernel panic may occur when cable pulled during system reboot (SCGCQ00841491) - Fixed an issue where 240VD support was not fully implemented (SCGCQ00652795) - Fixed an issue where the driver may crash if msix_disable=1 is passed to kernel as boot parameter (SCGCQ00383508) - Fixed an issue where IO errors may occur when connected to a Tape drive (SCGCQ00399947) - Fixed an issue where kernel may hang due to megaraid_sas driver deadlock (SCGCQ00857245) - Fixed an issue where kernel may panic when deleting VD and background IO is occurring (SCGCQ00803468) - Fixed an issue where crash dump may be disabled after an Online Controller Reset (SCGCQ00601138) - Fixed an issue in 32bit OSs where driver may not load on boot (SCGCQ00362423) - Fixed an issue where deadlock may occur (SCGCQ00846933) - Fixed an issue where a kernel panic may occur because IRQs are not freed before disabling MSI-X interrupts (SCGCQ00827403) - Fixed an issue where multiple Online Controller Resets can trigger a Core Exception (SCGCQ00707592) - Fixed an issue where crash dump may not be performed properly (SCGCQ00593374) - Fixed an issue where firmware may fault with CacheCade (SCGCQ00796461) - Fixed an issue where adapter may hang (SCGCQ00709216) - Fixed an issue where an offline VD may cause boot hangs (SCGCQ00284564) - Fixed an issue where kernel may panic (SCGCQ00820349) - Fixed an issue where kernel may crash in megaraid_sas driver with CacheCade if there are many Automatic Event Notifications and LD sync operations occurring (SCGCQ00712031) - Fixed an issue where system may hang with CacheCade (SCGCQ00687881) - Fixed an issue where the same disk may show multiple times in OS (SCGCQ00568992) - Fixed an issue where kernel may panic on Linux kernels version 3.0 or greater (SCGCQ00561505) - Fixed an issue where invalid IO statistics may be provided if driver supports more than just 512b sector drives (SCGCQ00282615) - Fixed an issue where driver fails to reboot system due to outstanding IOs in SCSI mid-layer when controller is in error state (SCGCQ00362023) Enhancements - Added ability for JBOD IOs going via firmware path to use timeout value provided by OS (SCGCQ00764795) - Added a retry of IO commands as LDIO if raid map sync is failed with MFI_STAT_CONFIG_SEQ_MISMATCH (SCGCQ00712510) - Added support for 4k sector drives if the system supports it (SCGCQ00259244) - Added support for driver to perform an Online Controller Reset if the controller is not responding (SCGCQ00820389) - Fixed an issue where system may hang on S3 resume (SCGCQ00758933) - Added a feature to prevent command block with FastPath after JBOD drive replacement (SCGCQ00806534) - Enhanced 1MB IO support (SCGCQ00816313) - Added support for "megaraid_sas.disable_ext_io=1" boot parameter to disable 1M IO support (SCGCQ00911362) - Added support for Secure JBOD (SCGCQ00711555, SCGCQ00753765) - Fixed an issue where user space applications may hang if IOCtl is sent prior a kill adapter issued (SCGCQ00759916) - Fixed an issue where OS may crash on a SCSI IO timeout (SCGCQ00631210) - Fixed an issue where system may fail to reboot or will kernel panic on init 6 if controller has faulted (SCGCQ00859634) - Fixed an issue where firmware may fault (SCGCQ00702536) - Fixed an issue where controller may crash during system power cycle (SCGCQ00647390) - Fixed an issue where kernel may crash when megaraid_sas driver is loaded but no MegaRAID controllers are present (SCGCQ00282968) Version 6.806.09.00 - New Function Only/No fixes -------------------
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
StorCLI (Command Line) Utility for Storage Management Adapters Supported: ThinkSystem RAID 530-8i PCIe 12Gb Adapter (7Y37A01082) ThinkSystem RAID 530-4i Flex Adapter (7M17A03932) ThinkSystem RAID 530-4i Flex Adapter (7M27A03918) ThinkSystem RAID 530-8i Dense Adapter (SD530 RAID) ThinkSystem RAID 530-16i PCIe 12Gb Adapter (4Y37A09727) ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapterr (4Y37A78834) ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter (4Y37A78835) ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter (7Y37A01083) ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter (4Y37A09722) ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter (7Y37A01084) ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter (7Y37A01085) ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter (7Y37A01086) ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter (7Y37A01087) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M17A03933) ThinkSystem RAID 930-4i 2GB Flash Flex Adapter (7M27A03917) ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter(4Y37A09721) ServeRAID M1210 SAS/SATA Controller (00JY194) ServeRAID M1215 SAS/SATA Controller (46C9114) LSI SAS3004 RAID (NA-SAS3004-B) LSI SAS3004 RAID (NA-SAS3004-N) ServeRAID M5210 SAS/SATA Controller (46C9110) ServeRAID M5225-2GB SAS/SATA Controller(00AE938) ServeRAID M5215 with 2GB Flash Enablement Flex System x240 M5 (00JX142) ServeRAID M5210e SAS/SATA Controller (46C9117CTO) ServeRAID M5120 SAS/SATA Controller (81Y4478) IBM Flex System Storage Expansion Node (68Y8588) ServeRAID M5115 SAS/SATA Controller for Flex System (90Y4390) ServeRAID M5100 Series IBM Flex System Flash Kit for X6 (44T1178) ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09728 ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09729 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09730 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter for 4Y37A09733 ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter for 4Y37A09735 NOTE TO SERVICE - Reference RETAIN #N/A 007.2705.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.27 Defects: Support for 16MB flash in storclif (DCSG01555459 SPDM invalidate on a slot with certificate is deleted/cleared does not return proper failure message (DCSG01200711 In "OTC" command output "phy info" "sasaddress" and vendor name is missing. (DCSG01416857 OTC command not displaying the Version header info when there is a partial failure (DCSG01453843 phyinfo legends are missing in ./storcli /c0/pall show command only for controller (DCSG01464352 autoconfig lowlatency change option is not working (DCSG01225927 Fixing storcli leaks (DCSG01436087 Storclif set clockmode does not return any message in either profile 30 or 32 (DCSG01343704 Storcli download command needs update. (DCSG01385977 Error message and Ctrl_prop needs update (DCSG01366236 Negative value is shown (DCSG01452047 CLI crashes when setting timestamp on all the enclosures (DCSG01275981 Show Drive Smart Info Failed without any error message (DCSG01453497 Fixing storcli leaks and unitialised variables (DCSG01528847 Schema validation fails with Drive details with (DCSG01312383 Removed switch and NVMe fields as part of the phy all show information (DCSG01429974 OTC command out of 2 coredump files only one coredump file is created. (DCSG01430008 Storcli fails to set "Preboottrace" to OFF. (DCSG01407684 Ph27_Storecli:pcie phy information should be displayed in the "storcli64.exe /c0/lnall show" command output. (DCSG01430854 show events command is missing in IT help command list (DCSG01440137 storcli /pall show command fails with "Unable to retrieve PcieIoUnitPage0 information" when executed on HBA (DCSG01451391 set sasadd command runs successfully on Megaraid controller. (DCSG01451336 storcli log file ballooning in size when used as a compare file for controller properties (DCSG01440265 Failure Description for lnx commands in profile 32 not consistent (DCSG01327288 Storcli lists incorrect parameter options (DCSG01480789 New PSOC related properties are not being displayed (DCSG01214343 Storcli legends for "CertProv" is missing in 'storcli show" output (DCSG01230074 OTC command status is shown as failure even after collecting the data (DCSG01462898 As part of phy compare linkspeed command invalid description observed. (DCSG01463047 storcli to allow both del and delete keywords (DCSG01333727 StorcliF and Storcli64 command details are incorrect. (DCSG01431031 Storclif did not show correct 24G drive speed as 22.5Gb/s (DCSG01436600 storcli exits when chunksize is given as 0 (DCSG01441105 StorCLI Add help page for storcli64 /cx/ex set time command (DCSG01266055 StorCLI IT show vpd command gives Json error (DCSG01428172 Help indentation update (DCSG01303723 No reason for the failure during "Alarm: On/off/silence" (DCSG01451915 Multiple drive microcode updates fail if mode is not provided by user. (DCSG01509349 addvirtualdriveeachr0 creates R0 virtualdrive for incorrect drive format. (DCSG01445078 logfile command not working in EFI (DCSG01440821 drive fw download with incorrect fw detailed status not seen and success status message noted (DCSG01192976 Expander firmware download command is getting success without firmware file (DCSG01368730 In "vmware_esxi_8" readme "./storcli64 /c0 set refclk =0" command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01446616 StorCLI phy -events commands (DCSG01452698 Fixing BD HUB reported license issues (DCSG01235456 otc command output some configuration pages are missing. (DCSG01417587 Incorrect details listed during V_D expansion. (DCSG01447578 Disabling PCIe lane is reporting failed/Invalid arguments (DCSG01334639 StorCLI crashes with /pall phyevents in Windows ARM (DCSG01462894 Expander firmware download is failing on enclosure behind IT using storcli (DCSG01360586 get otc command is failing in Linux when multiple coredump is present (DCSG01437688 scrutiny vib file version name noted wrong (DCSG01456900 VD creation is successful with PD in JBOD state (DCSG01186039 set time not listed in IT help / schema mapping list gives success message (DCSG01455624 Storcli set vpd command does not return any result, either pass or fail (DCSG01441368 volume table is not listed in sorted order for "cx show all " command (DCSG01187424 Heading of SAS and IOC pages in otc command are displayed wrong and Size in DB Register (DCSG01417593 Storcli fails with segmentation fault while query for enclosure and drive (DCSG01277632 Storcli shows no failure Description for "restart" operation. (DCSG01303781 refclk " command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01456786 Storcli does not have ESXi 8.x binary release and ESXi 6.x support mentioned in Readme. (DCSG01361836 'esxcli storcli controller get snapdump ' fails with syntax error (DCSG01464430 Storcli shows wrong information in DG details when JBOD/System is present (DCSG01521782 EFI StorcliO VPD update/flash fails (DCSG01559387 Changing of reset phy eveent commands to phy errorlogs (DCSG01448647 Lane information does not have the legends in the output (DCSG01445839 Description for PSOC flash from storcli is not proper when "resetnow" is used (DCSG01221186 There is no error message for lane show info command for lane number 16. (DCSG01446504 Return value for setting of large CCDelay does not match (DCSG01442317 issues with Consistency check delay and schema (DCSG01542373 StorCLI diag cmd returns successfully on M.2 Ctrl, even the Ctrl Firmware show not supported on iMR (DCSG01444219 Storcli needs update in error message and in detailed description. (DCSG01525040 observing "File read error !!!" while downloading enclosure firmware in UEFI shell (DCSG01521747 EGS: Storcli -Next Learn time in /cx show all differs with actual /Cv show time (DCSG01180101 Show drive command status shows failure with description "Show drive information failed", however show all status shows success with description "Show drive info (DCSG01462887 Storcli does not list proper "required" fields while creating V D using "addvdcachecade" option. (DCSG01453731 Storcli crashes during "debug level" set. (DCSG01361819 One of the element status displayed wrongly with extended status command (DCSG01372738 For the PI drives storcli64 shows PI as 'No' whereas LSA shows PI as capable (DCSG01395078 displaying proper description while setting invalid refclk. (DCSG01356146 Json schema support for StorCLI phy show command (DCSG01428869 Storcli shows output for invalid Lane. (DCSG01409017 Storcli "Enclosure" set time command needs update (DCSG01408981 All db commands are failing once after unregister the trace buffer. (DCSG01444766 Storcli returns missing char invalidate cmd output (DCSG01376779 Storcli shows duplicate information in readme files. (DCSG01323236 storcli phyevets is showing succss while executing on Mega RAID Controller (DCSG01464454 Storcli exits without returning anything on trying to set aso key with characters more than 127 (DCSG01409627 BGOP'S operations error message is inconsistent (DCSG01230073 Delete error-counters is not actually clearing the error counters (DCSG01416763 In windows OTC command output "capturing log serial number for the RTT Trace Buffer.." displays wrong. (DCSG01444337 Error message noted wrong with mode f command (DCSG01377687 Storcli shows success instead of failure for "show expansion" operation (DCSG01481384 Sending wrong image to controller has different message (DCSG01524642 output is jumbled for the eghs command output (DCSG01440963 Plugin for "start/stop/resume/pause" for consistency check and patrolread does not work. (DCSG01451161 Unable to set DS options. (DCSG01380122 In "vmware_esxi_8" readme "./storcli64 /c0/pall show phyevents " command is missing in "StorCLI command to ESXCLI plugin mapping". (DCSG01462816 Transform iMR command is mapped to incorrect esxcli command (DCSG01453766 otc commnad output "phy_info" data phy no 3 enable bit shows "N" Enbl bit instead of "y" in compare "storcli64.exe /c0/pall show" command . (DCSG01430015 Spaces are important (DCSG01303433 Lane information legends are missing in ./storcli /c0/lnall show command only for controller (DCSG01464343 For IT controller storcli "show eventloginfo" command output "status" and "description" displays wrong. (DCSG01448384 Using latest storecli "set refClk" command fail with error message. (DCSG01368858 Storcli Virtual drive creation should fail with "reusetargetid" parameter. (DCSG01430905 While executing "get otc" command there is no "storcli" version number displayed. (DCSG01437154 system time sync'up fails for expander with storcli command (DCSG01271785 PSOC hardware version is not displayed in storcli output. (DCSG01317465 (Port Of Defect DCSG01325851) While executing Enclosure Status cli displays wrong values. (DCSG01528830 (Port Of Defect DCSG01531725) storcli in Linux occasionally causing coredumpctl (DCSG01489233 (Port Of Defect DCSG01552077) autoconfig lowlatency change option is not working (DCSG01225927 (Port Of Defect DCSG01228069) Not able to get snapdump with -s=all option (DCSG01447404 (Port Of Defect DCSG01447574) Created 100 MB virtual drive with 1024K strip size on 4K sector size target device but the created size is 96MB (DCSG01320102 (Port Of Defect DCSG01329183) Using cachevd option returns that volum creation fails, but the volume is actually created (DCSG01432157 (Port Of Defect DCSG01432522) Storcli commands shows "Not enough memory to continue." with a page option. (DCSG01255030 (Port Of Defect DCSG01267413) Unable to create R0 V D's using "addvdeachr0" (DCSG01450023 (Port Of Defect DCSG01453727) VD creation is successful with PD in JBOD state (DCSG01186039 (Port Of Defect DCSG01187950) Physical drives count mismatch is there if compared with the actual drives present when tape drive is connected (DCSG01491544 (Port Of Defect DCSG01493435) Storcli crashes while Upgrading PSOC image for IT card (DCSG01446520 (Port Of Defect DCSG01490408) Set linkspeed operation asks for system reboot when the operation fails. (DCSG01554840 (Port Of Defect DCSG01557410) VD table is not listed in sorted order for "cx show all " command (DCSG01187424 (Port Of Defect DCSG01187947) In set security command help, file=filename is shown, but does not seem to work. (DCSG01432351 (Port Of Defect DCSG01437189) Multiple Cli2 observations w.r.t command returning success for incorrect syntax, blank Volum size etc. (DCSG01466254 (Port Of Defect DCSG01466530) EnhancementRequests: Enhancing the enclosure download command to read chunk size as input (DCSG01191253 Storcli Support for UBM6 backplane (DCSG01238774 Support for PsoC catalog version checking on update. (DCSG01245656 Create security lock key using EKMS (DCSG01311276 Port of ScrutinyCLI commands to StorCLI (DCSG01415106 Add PERST control for NVMe drives (DCSG01400121 Prevent installation of inappropriate Firmware image (DCSG01421212 VMware ESXi 8.0 OS Support Tool chain migration (DCSG01176442 Allow CLI to run on perc branded cards (DCSG01219438 add PERST control mechanism for NVMe Physical Disks (DCSG01421205 Implement REFCLK control in storcli (DCSG01291369 Security Version Support on 96xx boards (DCSG01174566 Remove the check for heterogenous config and allow the user to change the link config irrespective of homogenous or heterogenous. (DCSG01171914 Add a new StorCLI command to "show all" faster (DCSG01303802 Need 95xx boards to perform equally or better than Invader when only slower RAID volumes comprised of SATA HDDs are attached. (DCSG01272082 SecureBoot: FW download operation fails with incorrect message (DCSG01132479 Time-sync between Host-Utilities and all the Expanders in the topology (DCSG01214261 95xx HBA controllers Support for multiple PSOC images (DCSG01203368 Remove PERST support from refclock commands for IT cards (DCSG01388007 Handling MPI blocked functions. (DCSG01373043 Port of ScrutinyCLI commands to StorCLI (DCSG01390110 Removing "PSOC Version" field from the controller detailed command (DCSG01270804 Support Drive drive image without using Host Memory (DCSG01454023 Allow reusing of TargetIDs without 120 seconds delay(DCSG01394604) VMware ESXi 8.0 OS Support (DCSG01258042 OS_Utils: The 'Device Speed' is shown as 24.0Gb/s for SAS4 drives (DCSG01388208 De-branding of OEM name from StorCLI (DCSG01312376 ESXCLI Plugin support with DSDK migration (DCSG01431017 Displaying PackageVersion for Aero-IT Images (DCSG01191525 Storcli: Implement REFCLK control (DCSG01232268 Hide nonvolatile key option in for temporary key option (DCSG01325680 (Port Of EnhancementRequest DCSG01328968) ESXCLI Plugin support with DSDK migration (DCSG01475599 (Port Of EnhancementRequest DCSG01483012) SAS-4 JBOD integration with RAID controllers (Harpoon) (DCSG01364599 (Port Of EnhancementRequest DCSG01373126) Move from 7.22 to 7.24 channel base for the R2 program (DCSG01345495 (Port Of EnhancementRequest DCSG01352227) OEM requesting FIPS support on Linux (DCSG01315666 (Port Of EnhancementRequest DCSG01507167) CLI to display the energypack serialNo content in decimal format (5 digits including leading zero) for Supercap (DCSG01452070 (Port Of EnhancementRequest DCSG01455486) Add a new StorCLI command to "show all" faster (DCSG01303802 (Port Of EnhancementRequest DCSG01453526) - (DCSG01064409 (Port Of EnhancementRequest DCSG01085133) 007.2206.0000.0000- Moderate Impact/Low Probability of Occurrence -------------------- MR 7.20 Defects: -Storcli : Copyright shows as year 2021 instead of 2022 & also build release year 2021 instead of 2022 & also build release year shows as 2021 instead of 2022.(DCSG01124638) -Error seen while flashing psoc.rom in efi CLI.(DCSG01131584) -storcli 7.2001 does not return values for a bad drive.(DCSG01052072) -Spellling of mismatch is displayed as "Missmatch" in "Encryption type missmatch" error message..(DCSG01091937) -Device Type for Backplane in Alilog shown as Enclosure.(DCSG01109911) -Storcli shows Protection Information (PI) capable drive i.e. "PI eligible" as No, however LSA shows it properly.(DCSG01145223) -CLI not iterating through MR_SAS_CONNECTORS for H750 controllers.(DCSG01077564) -Instance validation fails for "/c0 show all" and "controller-detailed-properties-schema.json".(DCSG01035798) -OS drive name shown as N/A for multiple VDs.(DCSG01101813) -Storclif reports BBU instead of cachevault for failed retention tests.(DCSG01092227) -Storclif 7.2005 can't start retention test, says No CacheVault Found!.(DCSG01130532) -Enclosure logical ID field is not displayed for BP connected to connected to Boca 540-16i controller.(DCSG01024654 (Port Of Defect DCSG01024693)) -Set Patrolread command hangs while setting "excludevd".(DCSG01101780 (Port Of Defect DCSG01102890)) -Strocli.efi utility got hung on issuing "storcli /c0 show" command.(DCSG01049757 (Port Of Defect DCSG01050540)) -"storcli /call show" shows jumbled drives in a Multi IT controller environment.(DCSG01040245 (Port Of Defect DCSG01040583)) -PD size displayed in Gib for some of the 4K drives is incorrect..(DCSG00389591 (Port Of Defect DCSG00994728)) -PD Firmware Release Number = N/A is displayed for drive which has valid Firmware Release Number.(DCSG01083763 (Port Of Defect DCSG01083800)) -Storcli shows success without proper description for "VD delete BBMT" command when no VD present..(DCSG01002466 (Port Of Defect DCSG01024694)) -Update splitpackage script for shenandoah.(DCSG00651204 (Port Of Defect DCSG00994744)) -While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883 (Port Of Defect DCSG01036901)) -While trying to import foreign config, Storcli is not showing drive as "Hotspare" if the user has only hot spares.(DCSG01028926 (Port Of Defect DCSG01029835)) EnhancementRequests: -Update ControllerInfo Structure with PartNumber - API Changes.(DCSG01064529) -Request for Win2022 Supportnfor their 16G Enablement launch, March 2022 RTS.(DCSG00977684) -MegaRAID key management feature: volatile key escrow.(DCSG00992844) -secureSignBin: implement feature to download the public key during signing or with explicit arg.(DCSG01035866) -DCSG01082488 -API change to support PD sanitize operations enhancements.(DCSG01070995) -Aero 9560/9580 - Add PSOC6 as Vision Controller.(DCSG01056506) -Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API.(DCSG01065378) -Change the attribute name "Secured" to "Locked" in PD Properties output.(DCSG01040562 (Port Of EnhancementRequest DCSG01040785)) -Handling of VD target-ID's individually even when target-ID is assigned beyond maxLDs.(DCSG01091990 (Port Of EnhancementRequest DCSG01092477)) -Windows Client Win11 OS Support.(DCSG01043616 (Port Of EnhancementRequest DCSG01068906)) 007.1907.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.19 Defects: -While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883) 007.1707.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.17 Defects: -StorCLI listing failed NVMe drives in non-sorted order.(DCSG00320844 -Instance Validation Failed for "/call/fall show all.json" and foreign-configuration-detailed-schema.json.(DCSG00408509 -MR7.16_storcli: VD creation with the remaining drives fails.(DCSG00303606 -Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 -Package Version is not displayed properly after flashing firmware..(DCSG00961822 -PH18 BETA - StorCLI - Update YEAR in the CLI banner.(DCSG00707142 -Storcli launch fails with permission denied message.(DCSG00972016 -Setting CC date and time exceeding the limit, needs to be handled.(DCSG00520110 -"rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337710 -Storcli lists "/ex show all" for "/cx show all" command..(DCSG00417504 -DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00359247 -Storcli: learnStartTime displayed incorrectly in command details.(DCSG00320649 -Storcli /cx set debug reset all help description needs an update.(DCSG00521571 -storcli /cx set flushwriteverify help needs an update.(DCSG00507067 -PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00315152 -PH18 PA - StorCLI - appropriate message needed for erase all excludemfg command.(DCSG00395234 -Storcli shows "success" with incorrect message INSTEAD of syntax error for "/c0/d1 set" command..(DCSG00543505 -storcli show alilog shows "SATA-3G" as device interface for 9361-16i.(DCSG00555672 -Handling PBLP component whild displaying Image component versions.(DCSG00301878 -MR_7.17: After Driver unload/load via DDV tools- Ctrl acces via Storcli exit with Segmentation Fault.(DCSG00426317 -coverity: fixing non-array delete and dereferencing before NULL checks.(DCSG00368376 -Handling the read-only file system from storcli.(DCSG00542683 -Updating new SPDM MPI errors.(DCSG00435039 -"Failed Drive not found" reported from enclosure level show repair command.(DCSG00423496 -Controller Lane show command is not working with individual Lanes.(DCSG00386181 -Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00469639 -VD creation fails from storcli even though free capacity is present in DG.(DCSG00757768 -Aero 7.15 CLI shows a extra space in the /c0 set cc h command.(DCSG00298943 -Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00408497 -show alilog command displays JBOD as volumes.(DCSG00556934 -Instance Validation Failed for "/call/fall import preview.json" and foreign-configuration-detailed-schema.json.(DCSG00408512 -Max commands for averaging needs to be removed from DPMstat RA output.(DCSG00286349 (Port Of Defect DCSG00306711) -Failure observed while running set sbr command.(DCSG00779151 (Port Of Defect DCSG00932922) -Storcli "/call/eall/sall download status" error message needs correction..(DCSG00735452 (Port Of Defect DCSG00757676) -Unified StorCLI MR7.15 - Fixing coverity issues - Part 1.(DCSG00290662 (Port Of Defect DCSG00368612) -Atlas 4.2: StorCLI lists wrong error message "Failed in standard Inquiry", when user tries to upgrade/downgrade all connected NVMe Drives FW at a time.(DCSG00309398 (Port Of Defect DCSG00313432) -The foreign config of DHS/GHS details is not listing under foreign config import preview.(DCSG00919659 (Port Of Defect DCSG00935761) -Invalid Array Size in ZB is displayed for Degraded R1 span Foreign VD in storcli foreign import preview.(DCSG00916209 (Port Of Defect DCSG00935751) -Logical ID of Cobra expander not displayed properly in Storcli and LSA.(DCSG00342456 (Port Of Defect DCSG00391477) -CLI crashes when issuing the phyerrorcounters command on a 14G Expander backplane.(DCSG00323054 (Port Of Defect DCSG00323721) -Show command status not proper when issued with wrong EID.(DCSG00906544 (Port Of Defect DCSG00935762) -Storcli shows no output for valid parameter for "/c0/p0,1,22 show" command..(DCSG00840944 (Port Of Defect DCSG00932927) -From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494 (Port Of Defect DCSG00391509) -Non Foreign drives GHS are listing under Foreign import preview.(DCSG00931210 (Port Of Defect DCSG00935765) -Storcli "show file" command does not report correct FW version.(DCSG00299788 (Port Of Defect DCSG00302030) -Storcli show incorrect property name for "/c0/d0,3 set hidden=off" command..(DCSG00733214 (Port Of Defect DCSG00758467) -Coverity fixing bad allocator and resource leaks.(DCSG00307346 (Port Of Defect DCSG00307355) -Vses Device Type is displayed as Enclosure for IT card.(DCSG00920244 (Port Of Defect DCSG00935772) -StorCLIF fail to flash firmware image of BTBL (BOOT_BLOCK) on Invader MR.(DCSG00330381 (Port Of Defect DCSG00353198) -Storcli throws junk value is shown on set consistency check.(DCSG00906989 (Port Of Defect DCSG00935693) -MR 7.15 StorCLI : Addressing Coverity defects.(DCSG00286677 (Port Of Defect DCSG00311222) -CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802 (Port Of Defect DCSG00935973) -VDs imported from Jbod mode to RAID do not have OS name available in Linux OS.(DCSG00968023 (Port Of Defect DCSG00975216) -CLI failing to stop a BGI or CC when paused..(DCSG00735544 (Port Of Defect DCSG00757870) -Enclosure phyerrorcounters fails in VMware platform.(DCSG00706496 (Port Of Defect DCSG00706497) -Storcli shows success for "set patrolread excludevd" command failure in the presence of VD..(DCSG00906735 (Port Of Defect DCSG00935770) -For empty SPDM slots 0 & 1 show security slot info command shows as Invalid data on IT controller..(DCSG00348125 (Port Of Defect DCSG00353186) -Segmentation fault noted with drive firmware update.(DCSG00758645 (Port Of Defect DCSG00932904) -VD creation output shows VD size as 0KB when it reaches maximum supported virtual disks(64VDs) in a DG..(DCSG00349415 (Port Of Defect DCSG00353914) -SAS drive Inquiry data is not shown in drive show all output.(DCSG00778367 (Port Of Defect DCSG00932917) -Fixing Coverity defects of MR 7.15.(DCSG00299981 (Port Of Defect DCSG00309219) -Post reboot incorrect lane speed is displayed in Storcli when user sets it to 16GT/s.(DCSG00383336 (Port Of Defect DCSG00395901) -On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266888) -Coverity defects - remove resource leaks, invalid types in function arguments.(DCSG00269017 (Port Of Defect DCSG00277861) -Storcli will not show LargeIOsupport is enabled/disabled on the controller.(DCSG00353195 (Port Of Defect DCSG00353882) -Storcli shows target id of the drive as boot drive instead of showing drive slot number for JBOD drives..(DCSG00344079 (Port Of Defect DCSG00353203) -MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282590) -Removed leading spaces for SATA drives.(DCSG00904104 (Port Of Defect DCSG00935692) -Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266881) -Size of Degraded R10 Foreign VD is displayed as 0 KB in storcli.(DCSG00916207 (Port Of Defect DCSG00935746) EnhancementRequest: -Adding new License file and updating the build script to include the new file.(DCSG00324401 -Add CLI command to control Parity Read Cahce Bypass for SSD VDs.(DCSG00342282 -MR7.16 : Support WJ Pinning for both WB and WT Parity RAID VDs.(DCSG00214472 -Provide option in storcli to disable / enable the Preboot trace Buffer feature in MR FW..(DCSG00310366 -Enable cache retention testing on Shenandoah controllers for factory testing.(DCSG00340899 -Updating storcli code and makefiles to support VBAS builds on GCP.(DCSG00412063 -Additional NameSpace behavior changes.(DCSG00310386 -Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 -StorCLI: Automate the test cases specific to MR7.17 Product Requirements.(DCSG00433350 -Add support for reporting SPDM Measurement Specification and Hash Algorithm.(DCSG00301782 -Updating command legends as per the command output.(DCSG00083851 -IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00371061 -MR7.16: StorCLI does not show the SAS Address of the enclosure.(DCSG00255109 -Unified StorCLI 7.17 - x64 UEFI VBAS / GCP support.(DCSG00559813 -Updating Error Strings for NVME init error codes in Apps.(DCSG00434066 -MR7.16 StorCLI: Ruby SED Support.(DCSG00264744 -CLI to handle ERROR_BUSY from Windows storport.(DCSG00348813 (Port Of EnhancementRequest DCSG00353214) -Displaying "OS name" for VDs imported from EHBA mode to RAID.(DCSG00775114 (Port Of EnhancementRequest DCSG00932911) -Display Enclosure serial No in Storcli.(DCSG00500922 (Port Of EnhancementRequest DCSG00932906) -Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00500924 (Port Of EnhancementRequest DCSG00521828) -SEKM Support in CLI.(DCSG00433143 (Port Of EnhancementRequest DCSG00935780) -CLI: Package Stamping Verification During Firmware Update.(DCSG00239672 (Port Of EnhancementRequest DCSG00282815) -StorCLI has the ability to switch the OOB mode.(DCSG00547179 (Port Of EnhancementRequest DCSG00935783) -SMART Polling Improvement - PERC 10.(DCSG00249963 (Port Of EnhancementRequest DCSG00282814) -PERCcli turn off logging by default.(DCSG00255367 (Port Of EnhancementRequest DCSG00282813) -Remove the MFG date, Revision date and Rev from IT StorCLI output.(DCSG00415059 (Port Of EnhancementRequest DCSG00418372) -Display port information for NVMe Init failed drives.(DCSG00359418 (Port Of EnhancementRequest DCSG00421187) -storcli "set good" command can still be used for JBOD EPD-PT drives.(DCSG00318591 (Port Of EnhancementRequest DCSG00353919) -PERC11.1 - Dual x8 Support for 16 port Controllers.(DCSG00299060 (Port Of EnhancementRequest DCSG00323772) 007.1513.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.15 Defects: -CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802) -Handling the read-only file system from storcli.(DCSG00938327 (Port Of Defect DCSG00542683)) Enhancements: -Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00930193 (Port Of EnhancementRequest DCSG00500924)) 007.1510.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.15 Defects: -From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494) -PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00320641 (Port Of Defect DCSG00315152)) -StorCLI listing failed NVMe drives in non-sorted order.(DCSG00321815 (Port Of Defect DCSG00320844) -MR 7.16: Storcli: learnStartTime displayed incorrectly in command details.(DCSG00321908 (Port Of Defect DCSG00320649)) -rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337735 (Port Of Defect DCSG00337710)) -DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00360517 (Port Of Defect DCSG00359247)) -Controller Lane show command is not working with individual Lanes.(DCSG00386184 (Port Of Defect DCSG00386181)) -storcli /cx set flushwriteverify help needs an update.(DCSG00541982 (Port Of Defect DCSG00507067)) -"Failed Drive not found" reported from enclosure level show repair command.(DCSG00430578 (Port Of Defect DCSG00423496)) -Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00489855 (Port Of Defect DCSG00469639)) -Storcli /cx set debug reset all help description needs an update.(DCSG00538790 (Port Of Defect DCSG00521571)) EnhancementRequest: -Display Enclosure serial No in Storcli.(DCSG00500922) -IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00405900 (Port Of EnhancementRequest DCSG00371061)) 007.1326.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects: -Foreign Config Preview shows empty data when Foreign config is present with Rebuild is in Progress.(DCSG00261203) -Inconsist DG number in StorCLI.(DCSG00235157) -RTTdump shows success but it fails to download the dump..(DCSG00253652 (Port Of Defect DCSG00253719)) -Incorrect Adapter type shown in the perccli show all output.(DCSG00241405 (Port Of Defect DCSG00244145)) -Expander firmware download using with mode 5 option fail with error message..(DCSG00239524 (Port Of Defect DCSG00240685)) -With length command, CLI says Memory Exhausted.(DCSG00235628 (Port Of Defect DCSG00236791)) -Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 (Port Of Defect DCSG00286701)) -Observe CLI Crash on windows while setting Autoconfig option.(DCSG00253642 (Port Of Defect DCSG00253722)) -MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282592)) -"No Controller found" shown when controller is busy..(DCSG00248017 (Port Of Defect DCSG00253661)) -On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266886)) -Connector Name is incorrectly displayed when connector count goes beyond 8.(DCSG00249023 (Port Of Defect DCSG00252701)) -MR 7.15: Storcli: Instance Validation Failed for "virtual-drive-config-schema.json" and "/call delete config force".(DCSG00247992 (Port Of Defect DCSG00253761)) -With new MR API changes, storcli shows failure while changing accesspolicy.(DCSG00257307 (Port Of Defect DCSG00258140)) -MR 7.15: Storcli: Instance Validation Failed for "enclosure-fw-download-schema.json" and "enclosure FW download" output..(DCSG00250066 (Port Of Defect DCSG00253733)) -Show expansion shows wrong output in presence of JBODs..(DCSG00247163 (Port Of Defect DCSG00252417)) -Enclosure position value not listed properly in show all command.(DCSG00254935 (Port Of Defect DCSG00256384)) -Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266894)) -Expander firmware download help need to be corrected for IT controller..(DCSG00239870 (Port Of Defect DCSG00240680)) EnhancementRequests: -To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h.(DCSG00256271) -Additional FDE type for Ruby SED support.(DCSG00055878) -MFI SMP Port Num API changes.(DCSG00257777) -MR7 API: Add package incompatibility reporting.(DCSG00231443) -SMART Polling Improvement - API Changes.(DCSG00246317) -Implement customSign.exe CLI wrapper utility to help customers sign with their private key.(DCSG00234646) -Changes to support 16port connection to Expander with AeroIOC.(DCSG00254845) -Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 (Port Of EnhancementRequest DCSG00290359)) 007.1325.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.13 Fix issue: DCSG00235157 - Inconsist DG number in StorCLI Description: Customer reported the DG/Array/Row is incorrect to get from storcli and it causes "insert" command failure. 007.1324.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.13 Defects: -Storcli: Optl not mentioned in /call/dall show output..(DCSG00065740) -Instance Validation Failed for "/call set smartpollinterval=300" and controller-smartpollinterval-schema.(DCSG00057141) -StorCLI crash when create VD.(DCSG00052275) -/e: and /s: is not mentioned in the Convention for /storcli64 /c0/v0 start migrate detailed ?.(DCSG00143788) -BZ(186687):[AMD2P & Whitley] EXSi 7 can't boot up after install storcli.(DCSG00048516) -Storcli show Device type as backplane while no drives are connected.(DCSG00074732) -Help Description for Migrate shows "operation" printed twice in Storcli output..(DCSG00063696) -Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00057213) -Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements - Part 1.(DCSG00046195) -Foreign topology table display BT as "Y" for drives which are in foreign state..(DCSG00068453) -Storcli: Same help description across "/c0/e0 show" and "/c0/e0 show all"..(DCSG00064748) -While executing perccli, by default log file with storcli.log is getting generated..(DCSG00038031) -MR 7.13: Storcli(Regression): Syntax error seen while using "nolog" and "page" together as parameters.(DCSG00071417) -In Aero behind atlas configuration "NVME" drive firmware revision shows wrong.(DCSG00049614) -Storclif command for battery retention test issues command to start retention test which is an unsupported command.(DCSG00058688) -Show DPM with type LCT is not giving proper output and register DPM commands for all OS.(DCSG00033459) -Storcli: ProdID Legend abbreviation missing in /c0/eall show output..(DCSG00063317) -FW sometimes allows an invalid CLI command (set personality=HBA) to be successful and sets the personality to eHBA mode.(DCSG00129542) -Fixing Coverity defects.(DCSG00044004) -Unable to create JBOD using the legacy command with latest Perccli.(DCSG00118670) -MR 7.13: Storcli: GHS is shown as revertible.(DCSG00065815) -In the presence of Locked Foreign config, "/c0/fall del" shows incorrect output..(DCSG00062615) -StorCLI - '/c0 show nolog' reported as Un-supported Command.(DCSG00071410) -Set VD policy to WB (unsupported )should return failure in JBOD personality..(DCSG00076992) -Shenandoah_MRSA: Enclosure Bay count coming Wrong in CLI.(DCSG00074731) -Shenandoah_Storcli : Legend for ID in JBOD list is missing.(DCSG00069312) -Incorrect Legend abbreviation in storcli show output.(DCSG00058874) -MR 7.13: Storcli: controller add commands are listed along with vx commands..(DCSG00065744) -Even on giving wrong 'storclif delete config' command syntax, the config is cleared successfully without any error.(DCSG00055164) -Storcli.efi shows incorrect note for unsupported commands for MR controllers.(DCSG00056335) -VMware peccli, percli64 and storcli64 bit binary loads library from storcli 32 bit's installation path.(DCSG00074600) -StorCLI - /c0/eall/sall start locate not working for second enclosure connected.(DCSG00040244) -Instance Validation Failed for "/call show dpm" and controller-dpm-schema.json.(DCSG00057194) -Command description should be modified for storclif /cx set activityforlocate=.(DCSG00069746) -MR 7.13: Storcli: bbu not described in convention details.(DCSG00066314) -Shenandoah_storCLI: Add vd command for r0 getting successful with 512KB when mazStripeSize is 1MB.(DCSG00057003) -Fixing Coverity defects, uninitialized, unused variables and memory leaks.(DCSG00052049) -Start_entry is not a command parameter in show events command.(DCSG00067937) -On OS /cx/dall split mirror command shows success when there is no drive groups.(DCSG00069690) -Update the storcli readme with for Esxi 6.x and Esxi 7.0 releases.(DCSG00055533) -Extended the abbreviation in the legends.(DCSG00069703) -Shenandoah : storcli : Energy Pack show present for MR 216i controller , where the hardware is not supported.(DCSG00053888) -"set sbr" command mentioned in detailed help but not listed in help output..(DCSG00068444) -Creation of VD for with more than 64 drives is failing with "Cannot create configuration with x drives".(DCSG00056544) -Description of compare firmware ver command does not mention as IT supported command.(DCSG00070258) -Command description should be modified for /cx set alarm command.(DCSG00069709) -MR 7.13 : RSOD is seen for storcli.efi show command when the controller is in invalid state.(DCSG00066879) -StorCLI /cx restart is not supported in UEFI environment should be mentioned in help..(DCSG00068879) -Remove deprecated command 'show adpcount' from Ubuntu folder(readme).(DCSG00058329) -Segmentation fault seen while running OCR and Patrol read in loop on ESXi7.0 OS..(DCSG00066854) -Instance Validation Failed for "/call/fall import preview" and foreign-configuration-detailed-schema.json.(DCSG00068868) -Field for CV is missing in table as well as in legend for storcli64.exe show command.(DCSG00067075) -Restrict discovery of PERC HBA through StorCLI(Static binary).(DCSG00077037) -PH14 Alpha Aero - StorCLI - Difference in output noted for /cx/px set state command.(DCSG00055119) -MR 7.13 : Enclosure Device ID is mentioned in the legend for /cx/vall show command.(DCSG00067878) -MR 7.13 : Cosmetic issue is seen in the command name of /cx /cx show memscrubpatterns ?.(DCSG00067877) -Commands displayed twice in help description..(DCSG00068441) -Storcli DPM does not use legend "Resp" in EXT output.(DCSG00060706) -Enclosure ID is not mentioned as optional in "add Vd " command.(DCSG00058867) -Port information coming as internal and Location as Blank in when all the drives are removed from UBM2 Backplane.(DCSG00071756) -DPM delete help is listed under drive delete command group.(DCSG00053537) -No mention on convention in restart command description..(DCSG00068542) -Fixing Coverity defects - Uninitialized variable, resource leaks and null referencing.(DCSG00041202) -Set the PR to run on only configured array, but it complete the PR along with un-configured area..(DCSG00067103) -Fixing Coverity issues - Resource leaks.(DCSG00054690) -Storcli throws incorrect error message for /c0 add vd each r0 when Ubad drive is present in the setup..(DCSG00069698) -Use NVRAM to save PTB information -- API changes.(DCSG00082981) -Debug logs in FreeBSD is logging timestamp in different lines.(DCSG00069730) -"/c0 show nolog" shows as "un-supported command.(DCSG00068482) -Shenandoah_Storcli : The status of PD FW update on multiple drives is not proper when parallel is not included.(DCSG00069693) -Device type of UBM backplane is displayed as expander in Valvano-32i Controller managed port(C3)..(DCSG00054275) -Shenandoah_PA2:StorCLI not branding compliant for VD creation command Failure case -IO Policy specif.(DCSG00049610) -Storcli: px is not described in convention details..(DCSG00065742) -Unmap enabled not listed for unmap enabled VDs with /cx/vall show all cli command.(DCSG00112331) -Instance Validation Failed for "storcli64.exe show" and system-schema.json.(DCSG00057156) -Not able to create R1/R10 with 1MB size and strip size is 1MB.(DCSG00058162) -Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00063626) -StorCLI not reporting default oob settings from nvdata value.(DCSG00066530) -Executing storcli commands from external path throws error.(DCSG00072117) -StorCLI: /storcli /cx add vd verbose help ,strip size 512 is missing in help description under strip sizes..(DCSG00146343) -MR 7.13: Storcli: Caution mentioned instead of note..(DCSG00066554) -perccli is Reporting incorrect scheduled BBU Learn Date.(DCSG00109638) -Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements.(DCSG00046460) -Storcli64.exe /c0 show freespace shows unnecessary data when freespace is not present.(DCSG00055686) -Schema mapping list is not updated with DPM commands.(DCSG00057823) -Foreign DHS drive state is displayed as UGood under /c1/fall show all tab..(DCSG00068427) -MR 7.13: Storcli: logfile is not described in show dpmstat command..(DCSG00065838) -Statistics is spelled as Statitics in dpm stat commands.(DCSG00057112) -Cache Vault should be placed instead of battery for "storcli /cx/cv show status ?" help.(DCSG00143868) -Exit code showing "0" for failed storCLI command due to syntax error.(DCSG00054313) -Removal of log type from storcli logs.(DCSG00046794) -Discription for the term "NoVDs" is missing in the legends.(DCSG00068592) -start dpm returned error.(DCSG00035436) -Storcli: Show latest events output print shows 0.00 for all the number of events dumped (expected is the number of events queried for).(DCSG00068877) -Incorrect message noted when Ventura firmware flashed on Aero board.(DCSG00046031) -No consistency in the help details of "/c0/ex download" commands.(DCSG00064745) -Storcli license file is not present in the Vmware, Ubuntu & EFI folders.(DCSG00056538) -Storcli issuing 'add vd r0 drives=all' causes storcli to crash.(DCSG00053963) -No syntax error for multiple usage of "nolog" parameter in the command..(DCSG00066729) -Re-Host information is blank when ASO is not enabled.(DCSG00072628) -SSD Wear guage Parameter "SSD Percent used" to be removed from CLI.(DCSG00074791) -MR 7.13: Storcli: sx not described in convention details..(DCSG00066310) -Error message is improper for invalid raid level in volume creation.(DCSG00081057 (Port Of Defect DCSG00083789)) -Set MFG command does not throw an error when executed with empty file..(DCSG00074178 (Port Of Defect DCSG00074209)) -VD delete command works with multiple force options.(DCSG00165527 (Port Of Defect DCSG00167329)) -Syntax error for /c0 show AliLog ?.(DCSG00109790 (Port Of Defect DCSG00112470)) -storcli faults when issue drive poh command on Linux.(DCSG00075870 (Port Of Defect DCSG00075875)) -show memscrubpatterns shows status as success but failed in the description.(DCSG00077082 (Port Of Defect DCSG00103214)) -PH15 PA StorCLI - Segmentation fault observed when Sea IT PSOC image flashed on Ventura.(DCSG00075626 (Port Of Defect DCSG00212680)) -Wrong enclosure details are displayed when slot details are queried..(DCSG00127133 (Port Of Defect DCSG00139981)) -Storcli_VMWare gives failure messages when user tries to set the lanespeed.(DCSG00167210 (Port Of Defect DCSG00167280)) -"Download cpld" command displays incorrect output for MR controller..(DCSG00075734 (Port Of Defect DCSG00075863)) -The properties displayed in the command show htbparams has misspelled fields.(DCSG00104056 (Port Of Defect DCSG00105681)) -Instance Validation Failed for "/call/fall show" and foreign-configuration-schema.json.(DCSG00076415 (Port Of Defect DCSG00078173)) -storclif.exe /cx set copyback ? shows incorrect command name..(DCSG00075718 (Port Of Defect DCSG00075890)) -No description mentioned for "/cx set eghs" command..(DCSG00074290 (Port Of Defect DCSG00074768)) -Unified StorCLI Phase 15: storcli64 /cx add vd each help file missing options and format inconsistencies.(DCSG00139659 (Port Of Defect DCSG00139995)) -Aero Controller DPM does not report Max Response Time under 1 ms..(DCSG00099365 (Port Of Defect DCSG00102548)) -Storcli: Wrcache is mentioned instead of WT| WB.(DCSG00074284 (Port Of Defect DCSG00074767)) -Storclif allows to set Set SubOEMID as 1000 and more.(DCSG00079932 (Port Of Defect DCSG00080836)) -Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00031711 (Port Of Defect DCSG00063602)) -Storcli /cx show cc , does not shows the "Unit" for CC execution Delay..(DCSG00126229 (Port Of Defect DCSG00129753)) -storcli64.exe /c0/e1/s1 start sanitize throws syntax error..(DCSG00129738 (Port Of Defect DCSG00129750)) -forcehcb is executed with incorrect description in OS level..(DCSG00080961 (Port Of Defect DCSG00083295)) -"Show alilog" command output shows invalid PD ID in Virtual drive info..(DCSG00167354 (Port Of Defect DCSG00167449) -force is not defined under OPTIONS in storcli64 secureerase help file.(DCSG00148255 (Port Of Defect DCSG00150480)) -Storcli displays "Returned SCSI status for the command : Check condition" along with regular command.(DCSG00138580 (Port Of Defect DCSG00139200) -Aero Alpha: Storcli stops functioning during run of attached script.(DCSG00034379 (Port Of Defect DCSG00039682) -/vx is mentioned in the convention for storclif64.exe /cx set cc detailed ?.(DCSG00075700 (Port Of Defect DCSG00075894)) -DCSG00096587.(DCSG00104055 (Port Of Defect DCSG00108742)) -Avenger: ./storcli2 /c0 show ds all command(not present) shows the output of /c0 show all.(DCSG00061163 (Port Of Defect DCSG00080485) -PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup.(DCSG00050891 (Port Of Defect DCSG00079275)) -Storcli output starts with "GetCtrlInfo : ProcessLibCommand failed; retCode = 0xFF" for all command.(DCSG00214170 (Port Of Defect DCSG00214248)) -"OS Drive Name" does not display the details in "vall show all" for esxi OS.(DCSG00102559 (Port Of Defect DCSG00103190)) -Storcli: "show bbmt" displays output for an invalid VD..(DCSG00228667 (Port Of Defect DCSG00230346)) -Storcli command description shows none for Download firmware failure.(DCSG00221431 (Port Of Defect DCSG00223281)) -Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json.(DCSG00132488 (Port Of Defect DCSG00137828)) -NoVDs is displayed in dall show output..(DCSG00074628 (Port Of Defect DCSG00074763)) -"reset errorcounters" command mentions options under conventions.(DCSG00074288 (Port Of Defect DCSG00074764)) -PH16 PA - StorCLI - Compare fwprodid help page needs to be updated.(DCSG00167732 (Port Of Defect DCSG00215133)) -Display basic secure boot details for Sea IT controller.(DCSG00074184 (Port Of Defect DCSG00074218)) -No consistency in the description of Force option.(DCSG00074283 (Port Of Defect DCSG00074765)) -Storcli /c0/eall show status extended command fails to generate any output for ARM server backpla.(DCSG00146359 (Port Of Defect DCSG00150479)) -Debug log configuration file for perccli is taking storcliconf.ini.(DCSG00074691 (Port Of Defect DCSG00074757)) -Compare fwprodid command fails for 9500-16i.(DCSG00092943 (Port Of Defect DCSG00115266)) -Handling of controller properties related to drive FW download.(DCSG00138192 (Port Of Defect DCSG00139266)) -In command storcli /cx/ex/sx show DPM type=Ext , Sectors Read (Written) is not displayed correctly.(DCSG00083167 (Port Of Defect DCSG00103210)) -Ph16 PA: Storcli crash observed while running show all with NVMe drives connected.(DCSG00150686 (Port Of Defect DCSG00167881)) -Description for "profileid= " is missing in help and detailed help.(DCSG00152251 (Port Of Defect DCSG00152935)) -EKMS Boot Agent Status is not updating properly..(DCSG00049004 (Port Of Defect DCSG00050289)) -MR 7.15: Storcli: Force option is mentioned as "For".(DCSG00223195 (Port Of Defect DCSG00225259)) -Storcli displays 255 max spin-up drive count in help description instead of 240.(DCSG00098081 (Port Of Defect DCSG00108741)) -"Compare factorysettings" command displays incorrect output for wrong input file.(DCSG00075762 (Port Of Defect DCSG00075888)) -Storcli64 /cx show spinupdrivecount help file description needs update.(DCSG00150052 (Port Of Defect DCSG00150459) -Segmentation with controller show summary command when controller is in unsupported state.(DCSG00215109 (Port Of Defect DCSG00215118)) -StorCLI show autoconfig does not display all properties it can set.(DCSG00071834 (Port Of Defect DCSG00080859)) -Storcli returns wrong Operating system in Windows..(DCSG00037088 (Port Of Defect DCSG00037336)) -No description for "set autoconfig=R0 immediate" command..(DCSG00129610 (Port Of Defect DCSG00129762)) -Displaying connected portnumber as per API supportMoreThan16Phys.(DCSG00104331 (Port Of Defect DCSG00108740)) -Compare Factory command execution fails in storclif.(DCSG00074182 (Port Of Defect DCSG00074207)) EnhancementRequests: -HPE : Windows and Linux StorCLI signing.(DCSG00053511) -Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG..(DCSG00105430) -API change to support ISE completion status.(DCSG00065881) -MR API: Change event class for SPDM events.(DCSG00134416) -API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI.(DCSG00222915) -Perccli: Need a mechanism to get supported device protocols for each controller form factor.(DCSG00117742) -support for sanitize command.(DCSG00108999) -Shenandoah: Support for the New Energy Pack states.(DCSG00043240) -Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713) -Remove Help Text for lanespeed commands.(DCSG00099939) -Shenandoah: Change the CLI installation Directory name from Megaraid to hpe.(DCSG00053988) -Porting storcli source from V8 Clearcase to CC9 GCP database.(DCSG00013486) -Creating VD with 0 MB or GB should not be allowed to succeed --ve case boundary value scenario.(DCSG00048859) -MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534) -DCSG00129388 -Support to display drive connector name information for SAS3.5 IT Controllers.(DCSG00120994) -Add segment area into pci information of Megaraid controller in storcli.(DCSG00032694) -Populate secureboot properties "KeyUpdatePending" and "Remaining Secure Boot Key slots" in StorCLI.(DCSG00101684) -Remove (hide) PCIe Link form in HII and from CLI for Perc11.(DCSG00077856) -Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066) -Signing Linux executables via GPG method in HSM.(DCSG00077215) -Shenandoah: Creating VD with 0 MB or GB should not be allowed to succeed - Part 2.(DCSG00053587) -Shenandoah: SSD Wear Gauage.(DCSG00046064) -MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355) -Add /px linkspeed back to help text.(DCSG00126913) -HSW Applications to not send close DCMD as the first command to perform Firmware update.(DCSG00055146) -Update/remove Snapdump save count field in show snapdump command based on FW support.(DCSG00038800) -Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780) -API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058) -Add new security events.(DCSG00167313) -Request for DPMstat support in MegaRAID SAS 3.5 controllers in storcli.(DCSG00032273) -MR API: update field in event structure..(DCSG00093331) -Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286) -SMART Polling Improvement- API Changes.(DCSG00214352) -References to MR_ENCL_LIST and MR_ENCL_LIST_EXT should be based on the support bit.(DCSG00037323) -Shenandoah: Type 2 Back plane Support for StorCLI.(DCSG00054795) -StorCLI: Implementing span depth logic and pd per array count for RAID 10.(DCSG00049781) -Updating BST scripts to support auto BST through VBAS in clear case version 9.(DCSG00050763) -FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event.(DCSG00086780) -Revert the CLI Help Text for backwards compatibility to include Dimmer Switch 3.(DCSG00068659) -Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10.(DCSG00073393) -New MFI Stat for the updated recon behavior.(DCSG00229416) -Shenandoah: Remove Span setting for RAID 1 & 10.(DCSG00043198) -Restore Factory Default doesn't prompt user to reboot the system after being performed.(DCSG00122000) -MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security.(DCSG00106380) -Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847) -Phase 14 : StorCLI should provide power cycle message post erase all command is executed.(DCSG00039542) -Enhancement of Enclosure MultiPath algorithm in storcli.(DCSG00075191 (Port Of EnhancementRequest DCSG00079538)) -Support to generate storcli static library.(DCSG00075265 (Port Of EnhancementRequest DCSG00075687) -Updating toolchain for VMware7.0 GA.(DCSG00134764 (Port Of EnhancementRequest DCSG00136269)) 007.1212.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- MR 7.12 Defects: StorCLI should refer to MR_PD_INFO.properties.ISECapable to display "Cryptographic Erase Capable" field - Revert of SCG(DCSG00014660) Making the Predictivefaliure check OEM specific in controller health algorithm(DCSG00014971) HBA345_Dev_UT: Enclosure position value in perccli is same for both front and rear BP's(DCSG00033180 Cisco - CSCVr89052 - PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup(DCSG00050891) StorCLI Point release RO DCSG00079546 - Windows binaries are missing from the RO(DCSG00081022) StorCLI 7.10 point release - /cx erase help not listing all supported commands(DCSG00081294) StorCLI 7.10 point release - Update license files to RO DCSG00079546(DCSG00081298) Removal of unsupported phy commands on IT3 controller(DCSG00025416) Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(DCSG00015875) MR_6.14_Huawei: OnDemand Snapdump in Windows gives failure message "RTTdump Feature not supported"(DCSG00020717) help is not proper for show events and set copyback commands(DCSG00005503) MR 7.12: Storcli: Instance Validation Failed for "/call show all" and controller-detailed-properties-schema(DCSG00006331) MR 7.12: Storcli: Instance Validation Failed for "/call/pall show all" and controller-phyerrorcounters-schema(DCSG00006853) Orion PA9 : Convention comes in same line while performing help for /c0/e0/s0 download.(DCSG00008084) MR_7.12_Storcli: Xenserver8: "Core dumped" while executing "/call/eall show all" and "/call/eall/sall show all"(DCSG00009400) Aero DBU PA7 : Init is in progress error message is thrown by Storcli for start migrate command when VD erase is in pro(DCSG00012344) Orion PA9 : Storcli version mismatch as compared in storcli -v and storcli properties(DCSG00014485) Orion PA9 : Storcli crashes while performing storcli /c0 show(DCSG00014486) Storcli show all cmd displaying "AVAGO" in scheduled tasks info(DCSG00014580) Aero DBU PA7 : Storcli displays multiple error messages when user enters incorrect device ID during migrate operation.(DCSG00014644) Fixing Coverity defects - resource leaks and null referencing(DCSG00015721) Correcting the detailed help syntax(DCSG00016268) MR7.12 StorCLI: Ouptput message Description wrong for StorCLI VD policy change from WT -WB(DCSG00016372) StorCLI: Fixing coverity defects and adding debug statement(DCSG00019683) perccli windows binary property page has storcli references(DCSG00019800) Aero DBU Alpha : Storcli displays incorrect error message for "add vd each r0" command when SED drive is connected in t(DCSG00019816) Application Exit code is always success for UEFI StorCLI(DCSG00020670) MR 7.12 LSA "instant secure erase" is not found in storcli as cli use secureerase(DCSG00022096) Help content for Drive Init is not showing it as Clear operation(DCSG00022893) MR7.12_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(DCSG00022942) MR 7.12: Storcli: Instance Validation Failed for "/call start Diag Duration=40" and controller-diag-schema(DCSG00023543) MR 7.12: Storcli: Instance Validation Failed for "/call show linkconfig " and controller-linkconfig-schema(DCSG00023545) Aero Alpha : Storcli throw Segmentation Fault in Driver load error handing path -(DCSG00024554) MR 7.12_Storcli: On ARM server the latest storcli Vendor,Licenses,URL and distribution shows as "AVAGO Technologies"(DCSG00025885) Aero DBU Alpha - Scheduling is displayed as Schedulling under "/cx set pr ? " command description(DCSG00027203) Add warning/recommendation messages for changing lane speeds(DCSG00027869) Orion MR : Description for storcli output is not proper after collecting the snapdump with id=all(DCSG00031711) Aero Alpha: Storcli stops functioning during run of attached script(DCSG00034379) Storcli returns wrong Operating system in Windows.(DCSG00037088) MR 7.12_Storcli: The latest storcli vmware build reference URL shows "http://www.lsi.com"(DCSG00039104) MR 7.12_Storcli: The latest storcli vmware build 007.1209.0000.0000 shows older package version(DCSG00039112) PERC 11:EKMS:PKG 2973: EKMS Boot Agent Status is not updating properly.(DCSG00049004) PH13 StorCLI PA - Update help section about 'nolog' option(DCSG00002975) PH13 PA - StorCLI - Incorrect message for /call/pall show all command(DCSG00003003) StorCLI_7.12_Ph13:Phyreset Fails on IT controllers(DCSG00005488) PH13 PA - StorCLI - NVMe drive linkspeed not seen with /cx/pall show(DCSG00009522) With IT controller for set or reset with invalid phy is not showing error(DCSG00010226) Aero_storecli:Using latest storecli Firmware product id parameter value fail to display.(DCSG00011446) MR_7.12: Storcli: Segmentation Fault for "storcli64 page"(DCSG00012563) Storcli ph13: Fixing array size for function DEBUG_LOG(DCSG00014665) Aero Orion IT:- Mismatched phy info listed for 440-16e/440-16i(DCSG00023320) Enclosure position value in storcli is same for both front and rear BP's(DCSG00031302) Misleading error message when create unmap VD with storcli64.exe /c0 add vd each r0 unmap using unmap and non-unmap PDs(SCGCQ02059720) StorCLI: Debug prints enabled in latest Phase 12 PA storCLI.efi image(SCGCQ02097317) Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101372) MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json(SCGCQ02112192) DBU Aero PA4 : Cosmetic error is seen in command description for Show SSDThermalPollInterval ?(SCGCQ02124673) Aero A0 PA4: "Storcli /c# set jbod=on" shows success but does nothing(SCGCQ02117219) Aero (DBU PA4):Storcli: Junk character in PD start locate command description.(SCGCQ02125654) Phyreset Fails on IT controllers and update help(SCGCQ02169242) Drive mode-e fw download with activatenow is not working(SCGCQ02142068) MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02150924) MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02165933) Phase 12 - Oct Huawei DET - "./storcli64 /c0/pall show" Command Fails With "Null pointer exception"(SCGCQ02175414) Phase 16 (IR) - Oct Huawei DET - Unsupported Drive State is Displayed for "./storcli /c0 show" Command(SCGCQ02170389) MR 7.11 - Oct Huawei DET - Nomenclature Issue for "rbld=Rebuild" In Storcli Show Help Menu for SAS3516(SCGCQ02170197) Usage of 64 bit address instead of 32bit address while sending commands to FW in uEFI driver less environment(SCGCQ02174934) MR_7.10_Storcli: Storcli displays incorrect error message for unmap VD creation with regular HDD drives.(SCGCQ02019751) PH12 PA - StorCLI crashes when call/pall show executed with SAS3 & Ventura boards(SCGCQ02103217) PH12 PA - StorCLI - Debug StorCLI binary is placed in both places of EFI dir RO SCGCQ02085693(SCGCQ02091140) PH12 PA - Update readme file in VMwareOP64 folder in accordance with PR SCGCQ01923533(SCGCQ02108550) MR 7.11: Storcli.efi: In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02115036) Aero (DBU PA4):Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) Aero DBU PA4 : storclif /cx show configautobalance ? help output shows the name as "show NCQ"(SCGCQ02124632) Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02136333) Aero (DBU PA5):Storcli: Storcli: "/c0 set patrolread ?" lists detailed help and snapdump rttdump is mentioned as optional.(SCGCQ02140873) MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02150921) Aero (DBU PA5):Storcli: Force is not mentioned as key word in "/cx/vx del" error message.(SCGCQ02142017) MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(SCGCQ02165944) Aero (DBU PA5):Storcli: "Ctrl" legend not mentioned.(SCGCQ02146822) MR7.11_Storcli: storcli set securitykey detailed help does not show description for all the options(SCGCQ02096732) MR7.11_Storcli: storcli show output shows UBUnsp as UBad Unsupported where as UGUnsp just Unsupported(SCGCQ02096722) Aero IT - PA3 - StorCLI crashes for 'storcli J command(SCGCQ02117749) Lenovo Orion IT:- Command to flash UEFI on Aero/sea HBA from storcli/scrutiny fails(SCGCQ02137751) Flashing of Completeflash fails on Sea IT controller(SCGCQ02139780) StorCLI: Fixing coverity defects(SCGCQ02123769) MR 7.11: Storcli: Instance Validation Failed for /call/show_smartpollinterval.json and controller-smartpollinterval-schema.js(SCGCQ02135516) DBU PA5 Aero : Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02132024) Aero (DBU PA5):Storcli: No "Rbld" legend during rebuild.M(SCGCQ02146819) complete Lane WWID is not displayed(SCGCQ02145716) Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176681) Adding missing syntax for the command deviceorderbyfirmware(SCGCQ02121705) MR 7.11: Storcli: Instance Validation Failed for "/call/vall show unmap" and vd-unmap-schema.json.(SCGCQ02113316) Aero (DBU PA5):Storcli: "completeflash" is listed in Windows help file.(SCGCQ02141931) Aero (DBU PA5):Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02140878) Force option is needed only for Parallel Drive microcode update, but it allows to take for normal also(SCGCQ02177086) StorCLI Copyright Notice Needs to be updated(SCGCQ02174040) Wrong error message when create unmap VD with unmap disable on controller(SCGCQ02064118) Aero DBU PA4 : storclif /cx delete colinfo ? shows syntax error(SCGCQ02124492) MR 7.11: Storcli: Instance Validation Failed for "/call show" and controller-properties-schema.json.(SCGCQ02108770) PH12 PA - StorCLI version not getting printed for show file command(SCGCQ02105185) Aero DBU PA4 : Command name shown in help output differs for storclif.efi /cx show limitmaxrateSATA ?(SCGCQ02124667) Aero DBU PA4 : Redundant information is displayed for set driveactivityled command in storclif.(SCGCQ02124675) Aero (DBU PA4):Storcli: Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) Aero DBU PA4 : storclif.efi /cx show deviceorderbyfirmware ? throws syntax error.(SCGCQ02124528) MR 7.11: Storcli: Instance Validation Failed for /call/show_consistencycheck.json and controller-cc-schema.json(SCGCQ02135510) Phase12-Storcli- In Windows storcli64.exe /c0 show htbparams is showing random values for SAS3 controller(SCGCQ02125598) Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02140859) PH12 BETA - /cx erase help not listing all commands(SCGCQ02146466) Aero (DBU PA5):Storcli: No consistency in the usage of "|" in the command such as "on|off".(SCGCQ02142022) Phase 12 - Oct Huawei DET - Delay Option In PD Download Operation is Not Honored(SCGCQ02176690) With IT controller for set or reset with invalid phy is not showing error(SCGCQ02181823) Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02184862) Drives connected to active backplanes not showing the phy info in connector name(SCGCQ02112424) PH12 PA - StorCLI - 9310-8i IR FW download fails(SCGCQ02121783) MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02114898) Aero PA6 - storcli snapdump id=x errors without optional file parameter(SCGCQ02161748) PH11 - StorCLI - Incorrect message for /call/pall show all command(SCGCQ02169536) cli does not allow to do crypto erase on SATA SSD.(SCGCQ02147075) MR7.11_Storcli: Storcli stop erase needs an help file update(SCGCQ02168895) Phase 12 - Oct Huawei DET - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180495) Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(SCGCQ02191421) Aero PA4 DBU : Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02123789) Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) Aero (DBU PA4):Storcli: /c0 compare lists /c0/px compare command.(SCGCQ02124246) StorCLI: Fixing coverity issue in libmod(SCGCQ02123790) SWR:Storcli: "Show" and "show all" output Description is shown as "No Enclosures found"(SCGCQ02146814) MR 7.11 storcli -help missing the verbose option(SCGCQ02158600) Phase 12 - Oct Huawei DET - PD FW Download is failing for Mode f(SCGCQ02168197) PH12 PA - StorCLI - Incorrect string displayed with show command in FreeBSD 11.2(SCGCQ02094529) PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02119004) MR 7.11: Storcli: Instance Validation Failed for "/call/v5 set bootdrive=off" andcontroller-bootdrive-schema.json.(SCGCQ02115786) StorCLI: Fixing coverity defects for second run(SCGCQ02125523) MR 7.11: Storcli: Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02135526) Aero (DBU PA5):Storcli: /c0 set ? lists bbu,mx,px and lnx commands.(SCGCQ02136689) Aero DBU PA4 : Storclif should not display vendor name in storclif.efi /cx/ex download help command(SCGCQ02123765) Aero (DBU PA5):Storcli: Improper spacing for the linkspeed description and "YY" parameter leads to confusion.(SCGCQ02139910) MR 7.11: Storcli: Instance Validation Failed for /call/show.json and controller-properties-schema.json(SCGCQ02135420) MR 6.14 - Oct Huawei DET - "Rbld=Rebuild" is Not Available In Storcli Show Help Menu for SAS3108(SCGCQ02170181) MR 7.11: Storcli: Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02150651) Aero (DBU PA5):Storcli: Help notes needs an update.(SCGCQ02146823) Phase 12 - Oct Huawei DET - Incorrect Status for PD FW Download (Ventura IT)(SCGCQ02173203) Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02174296) Enchancement: To bring MR 7.10 storcli change to CC9 GCP database(DCSG00013486) Support to generate storcli static library(DCSG00075265) Bring MR 7.11 storcli change to CC9 GCP database(DCSG00014492) Updating the Makefile and projects as per new CC/CQ changes(DCSG00003002) Updating the Json Schema files with respect to the latest code(DCSG00007394) Controller commands Json Schema files update as per the latest code(DCSG00007435) Schema validation : Schema update for VD/DG/Foreign related commands(DCSG00007453) Add UEFI Shell StorCLI support for 64-bit Ventura Gen MR Legacy Boot solutions (solutions without UEFI driver)(DCSG00008200) Changing the CBB download image type as per new MR API(DCSG00010253) Migrating StorCLI's 64 bit VMware toolchain to 6.8.7-13394445(DCSG00014503) PERC 11: Provide ability to expose SEP to host and disable PERC SES management in PercCLI / HII(DCSG00015020) Supporting build and BST process through VBAS in Clear Case version 9(DCSG00024818) Windows and Linux StorCLI HSM based signing support(DCSG00031618) StorCLI PH13: Adding interface for lane display and configuration command for IT controllers.(DCSG00007909) Atlas Support on Aero-IT(DCSG00008038) Concern for security key passed in from storcli to be read in process data(SCGCQ02066380) Support FMP Images in UEFI Version of PERCCli(SCGCQ02078649) Add segment area into pci information of Megaraid controller in Storlib and storcli(SCGCQ02201178) Create DVT / PVT PnP IDs for Cisco Pismo Beach card(SCGCQ02108965) Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066395) Enable SnapDump for iMR(SCGCQ02208421) HDET: Support in storCLI support PD firmware download for 3008IR/3008IT controllers(SCGCQ02160016) multi VSES implementation(SCGCQ02066438) Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066399) Add displaying list of enclosures in controller show and show all command(SCGCQ02124566) LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02085102) SAS 3_5 Ventura family UEFI NVMe drive serial number issue(SCGCQ02074657) Unmap error message changes as per new description in MR API(SCGCQ02115017) MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02066386) Lenovo Whitley/Orion - Addendum 7 - Lenovo request to support StorCLI & LSA for Valvano 28i (MR+Cub) and Custom Form Factor(SCGCQ02082612) 007.1022.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects : - PERCcli Help text is missing description for "Lane Information"(SCGCQ02150899) - Add NVMe width comments to mr.h(SCGCQ02146846) - Fix API changes done for NVMe readiness(SCGCQ02142981) - CLI returns "success" when attempting to set DS3 or DS4 to enabled(SCGCQ02116380) - CLI returns "success" when attempting to change the H840 controler to eHBA personality.(SCGCQ02114332) - CLI returns wrong error code upon failure(SCGCQ02084966) - HPE shenandoah: storcli crashes during show command when DGs present(SCGCQ02065695) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02045324) - ROP version not displayed with latest ROP version SCGCQ02035462(SCGCQ02041094) - FW flash fails to load the latest image after upgrade downgrade with resetnow option(SCGCQ02035152) - retentiontest command is successfully triggering BBU test on Shenandoah controller(SCGCQ02021398) - Storclio (007.0911.0000.0000) detailed help file doesn't have " locale " option for flashing FW in Dual/Active & Backup mode.(SCGCQ02012025) - hot spare reference in Add Spare command output(SCGCQ01897463) - Shenandoah:Strocli show all output return failure but generates output(SCGCQ01929191) - Junk message "STR_JBOD_OBJ" is displayed in the output of storcli /c0 show JBOD command.(SCGCQ01932770) - Shenandoah_StorCLI: No legend presend for VD Delete Failure(SCGCQ01936811) - Shenandoah_StorCLI:Setting Unmap=OFF gives success for a LD when unmap is not supported and not enabled on that LD(SCGCQ01940291) - Set WrCache= WB ,says success even though VD is in WT.Proper warning message should be given to the user(SCGCQ01940296) - Legend missing for LD BGI resume/pause commands(SCGCQ01940347) - System hangs while creating VD in EFI shell.(SCGCQ01945551) - Shenandoah_StorCLI: Storcli crashes on checking LD preserved cache info(SCGCQ01955069) - CLI is showing the incorrect OS version(SCGCQ01956276) - Unified StorCLI : Add extra space to CBB header(SCGCQ01956678) - PH10 Alpha - StorCLI throws "0 Failed 32782 Failed to get PD Info" when /c0 show executed in EFI(SCGCQ01960322) - JBOD list is not showing in order when using /cx show(SCGCQ01961527) - supported personalities has blank value(SCGCQ01965370) - storcli faults for enclosure show command(SCGCQ01985815) - MR7.10_PA1: Storcli binaries for RHEL/SLES OS is not present for ARM(SCGCQ02006374) - NVMe drive displays incorrect information with IT card(SCGCQ02009852) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02016762) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for snapdump commands.(SCGCQ02018073) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02018134) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02018135) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02018140) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02018333) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02019740) - Instance Validation Failed between " controller-lane-show-schema.json" and "/call/lnall show"(SCGCQ02019746) - Pending Image details are not populated after FW upgrade and downgrade.(SCGCQ02024065) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all "(SCGCQ02032911) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02034493) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02035370) - remove the maxconcurrentpd check from storcli and report fw returned failure(SCGCQ02053910) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02061340) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show_all"(SCGCQ02062957) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02064836) - Storcli: "show config" command shown as Un-supported.(SCGCQ02064839) - PH11 Alpha - StorCLI 'show file' command throws segmentation fault for complete flash image in FreeBSD(SCGCQ02065691) - Storcli: No schema files for htbparams commands.(SCGCQ02065698) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02065734) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02067575) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02069817) - Typo in storcli /c0 set linkspeed help(SCGCQ02070951) - Aero (DBU PA2): Storcli: No syntax error displayed for "storcli mronly" command.(SCGCQ02072746) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02076923) - Empty data is listed when we query for show linkconfig(SCGCQ02076931) - htbparams help output needs update.(SCGCQ02077156) - show/set lane speed shows success when we are in SAS profile(SCGCQ02078437) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02078513) - Recon command (./storcli /cx set recon) is throwing syntax error.(SCGCQ02081415) - storcli /c0/ex/s23,24 show patrol read doesnt not show error for slot 24 (Invalid Slot)(SCGCQ02082142) - Aero (DBU PA2): Storcli show detailed help does not list "show all " command.(SCGCQ02082303) - Aero (DBU PA2): Storcli: Get rttdump detailed help shows syntax error.(SCGCQ02082460) - Storcli: Incorrect message while executing "storcli64.exe /c0/v0 del discardcache"(SCGCQ02083828) - Failure status for /call/sall and /call/eall/sall command.(SCGCQ02084549) - Storcli: Error in /c0/f0 command output.(SCGCQ02089892) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02090770) - Storcli doesn't exit with controller status message after doing OFU.(SCGCQ02091548) - Libmod changes for SCGCQ02090770 (SCGCQ02096774) - Aero (DBU PA3): Storcli: FW hits Megamon while executing storcli in EFI shell when EFI Driver is unloaded.(SCGCQ02097647) - StorCLI crashes for 'storcli J command(SCGCQ02117749) - Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) - Controller Health Status not consisten across applications(SCGCQ02182243) - Perccli does not enable Power Save mode for UG & HS type 1 & type 2. (SCGCQ02125408) - StorCLI: Delete config failure message need correction(SCGCQ02086726) - StorCLI:VD reference in Delete preserved cahce command output -Branding(SCGCQ02083992) - VD reference in set JBOD command output message(SCGCQ02078507) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02075242) - STORCLI: Show command output having wrong legend for Slt for oem Hercules(SCGCQ02067616) - Grammatical error in Perccli message(SCGCQ02065513) - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02045967) - VD legend missing in the legend for Foreign config show all output(SCGCQ02016798) - Hercules:Shenandoah:Transformation is coming as Reconstruction , while migrating the Raid 1 to Raid 5 .(SCGCQ01897468) - Mis-spelled words in StorCli's Help(SCGCQ01898853) - Hot spare reference in storcli.exe /cx/ex/sx show all command output(SCGCQ01905019) - Reference to VD in storcli.exe /c1/jbodall delete command output(SCGCQ01905077) - Fixing coverity issues Removing dead code and Out of bound access(SCGCQ01924504) - Shenandoah_StorCLI: HotSpare reference in Add VD Command output(SCGCQ01936887) - storcli /c0 show events output not listing the Event ID's(SCGCQ01940290) - Shenandoah_StorCLI:Hot spare reference in storcli64 /cx show/set restorehotspare command outputs(SCGCQ01940437) - Shenandoah_StorcLI:Drive Group reference in Add dedicated spared drive command in CLI(SCGCQ01955167) - Intel NVMe drive "Model Number" displayed incorrect under Device Attributes(SCGCQ01957949) - Aero: Segmentation Fault in storcli /c0 show all(SCGCQ01996444) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02006450) - storcli gives error when the lane configuration is set as X8 (SCGCQ02007152) - MR_7.10_Storcli: No schema file for controller unmap commands(SCGCQ02016749) - MR_7.10_Storcli: Instance Validation Failed "controller-restorehotspareoninsertion-schema" and "set restorehotspare"(SCGCQ02016765) - MR_7.10_Storcli: Instance Validation Failed "controller-properties-schema" and "/c0 show"(SCGCQ02016768) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02016771) - MR_7.10_Storcli: Instance Validation Failed between "controller-autoconfig-schema.json" and "show autoconfig" JSON output.(SCGCQ02018227) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02018277) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02018305) - MR_7.10_Storcli: Instance Validation Failed between "system-schema.json" and "./storcli show" and "show all" JSON output.(SCGCQ02018313) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02018327) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02019729) - Storcli displays drive state as UBad instead of UBad (unsupported)(SCGCQ02031615) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02040779) - Fixing coverity issues Fixing resource leaks(SCGCQ02043601) - Storcli help file should show the expand size format.(SCGCQ02047109) - Updating the storcli schema mapping document (SCGCQ02050586) - PH11 Alpha - StorCLI - Parse error observed for command 'StorCLI J' while validating Jason(SCGCQ02053030) - JSON-SCHEMA : IT-Controller Json-schema validation erros in MR_SAS_Unified_StorCLI_7.10(SCGCQ02053914) - Aero: Storcli : Storcli crashed when Firmware upgrade tried on Sea controller(SCGCQ02060276) - Aero (DBU PA2): Storcli: JSON readme file does not have complete VD and PD support list.(SCGCQ02061328) - Instance Validation Failed bw "enclosure-drive-detailed-schema.json" & "/call/eall/sall show all"(SCGCQ02062958) - PH11 Alpha - StorCLI - Compare linkspeed command failed for 6Gbps link(SCGCQ02063932) - Invalid aero controllers are not displayed with apt message in driver less mode(SCGCQ02065581) - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02072448) - Aero (DBU PA2): Storcli: /cx/mx command does not mention about "Auto" settings.(SCGCQ02082208) - Storcli: Force is mentioned as optional in snapdump delete command. (SCGCQ02083822) - Help of /cx/px compare command needs update and /cx/px reset ? shows syntax error.(SCGCQ02084752) - No proper legends in /fall output.(SCGCQ02100491) - Aero (DBU PA3): Storcli: Incorrect schema mapping for "/cx set autoconfig " command.(SCGCQ02101558) - Storcli: OCR helps needs update.(SCGCQ02113241) - Storcli: No proper description of set and show sesmultipathcfg.(SCGCQ02113358) - StorCLI: File sync issue with rel and dev stream for MR 7.10 (SCGCQ02116806) - Storcli script stops with error "can't fork: Cannot allocate memory" (SCGCQ02184427) - IT- CLI treats EID and Partner Device ID as two different enclosure during pd info command and fails.(SCGCQ02185442) - "/eall show" will not show enclosure details if it is in multitpath & no drives connected.(SCGCQ02186022) - Legacy messages present with create and rekey of securitykey on controller(SCGCQ01581843) - Shenandoah_StorCLI:VD reference in CLI outout for Firmware update command failure case(SCGCQ02083991) - StorCLI: VD listing for c0 show and vall show is toggled (SCGCQ02078936) - output information for link configuration is displayed incorrectly(SCGCQ02073046) - Drive Groups is shown instead of arrays in show all command(SCGCQ02048660) - Help is not updated for get snapdump without ID option.(SCGCQ02046991) - StorcliO show oob command fails for Invader based cards(SCGCQ02040783) - Adding debug logs to Mfi files(SCGCQ01891583) - MR7.8_Storcli: Storcli fails to install on ARM server with Missing Maintainer message(SCGCQ01919830) - StorCLI show SAS address for NVMe drives (SCGCQ01921258) - Unified StorCLI 7.9 : Fixing coverity issues - Dead code,resource leaks,and memory corruption - Part 1(SCGCQ01925503) - Incorrect help option for set autoconfig in StorCli's Help(SCGCQ01932035) - Unmap enabled property is shown in VD detailed properties when controller does not support unmap (SCGCQ01932177) - Unified StorCLI - Aero : "FullFlashImage" environmental variable component stamp change(SCGCQ01963738) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02018137) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON output.(SCGCQ02018322) - MR_7.10_Storcli: Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show"(SCGCQ02024327) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034064) - Aero IT - PA1 - StorCLI - BIOS verion not displayed with flash file using 'show file' command(SCGCQ02034490) - failure in StorCLI enclosure show status (SCGCQ02040640) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02042106) - Incorrect status displayed for pause rebuild command.(SCGCQ02043610) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044777) - Port information is not displayed for Vses Backplane(SCGCQ02053070) - "c0 delete ?" does not list snapdump command.(SCGCQ02053639) - Incorrect status displayed for resume copyback command.(SCGCQ02062834) - Aero (DBU PA2): Storcli: Instance Validation Failed bw "vd-operations-migrate-schema.json" & "start_migrate"(SCGCQ02062960) - Aero (DBU PA2): Storcli: Result shows blank for "resume patrolread" failure case.(SCGCQ02064795) - Fail to set the linkconfig . (SCGCQ02070797) - Storcli /c2 set linkconfig conname=c0,c1 configid=14 returns invalid syntax error(SCGCQ02070953) - Aero DBU PA2 : Syntax error is seen in storcli /cx(x|all (SCGCQ02077085) - Aero (DBU PA2): Storcli: Syntax error for "/c0 download psoc/efibios/cpld/fcode ?" download commands.(SCGCQ02077175) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02078409) - Incorrect string displayed in show command in FreeBSD OS(SCGCQ02082949) - MR_7.10_Storcli: "storcli show file=filepath" command shows failure status.(SCGCQ02085630) - PCI Linkconfig configid status is failure, even though it was set(SCGCQ02086669) - Storecli_Aero: Using latest storecli show file command "Aero-DVT -HBA 9500-16e" board output version number shows wrong.(SCGCQ02089427) - Libmods changes for defect SCGCQ02062957(SCGCQ02089862) - Help update for "add vd cachevd" command as Normal VD is created with failure status.(SCGCQ02091155) - Preserved cache help file shows a mismatch in command and the convention.(SCGCQ02106218) - Aero DBU PA4 : Storcli doesn't show the convention details properly for storclio /cx/px show command(SCGCQ02113377) - Aero (DBU PA4):Storcli: Syntax error for /c0 show AliLog ?(SCGCQ02113506) - Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) - Misleading error msg "157 Failed Cannot mix unmap and non-unmap physical drives in same array"(SCGCQ02151484) - Cryptographic erase field is shown "yes" but crypto erase fails.(SCGCQ02175346) - Device Type for non-UBM backplanes are being shown as Enclosure instead of Backplane(SCGCQ02101095) - Multiple status messages are displayed in the output (SCGCQ02073042) - Controller health status is shown as optimal when megacell cable is disconnected.(SCGCQ02021393) - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"(SCGCQ01889700) - Shenandoah_StorCLI:32 Binary crashes on giving invalid input to the command storcli.exe /c0/jbod0 show(SCGCQ01905831) - For NVMe drive use the term NVMe instead of PCIe(SCGCQ01923119) - PD show all command displays SSD weargauge details , which is not required.(SCGCQ01927864) - MR_7.10_Storcli: Junk character in error message while creating SED vd with regular HDD drives.(SCGCQ02016701) - MR_7.10_Storcli: Incorrect command syntax mentioned in Schema_mapping_list.xlsx file for "/cx set autoconfig" command.(SCGCQ02018097) - Instance Validation Failed between "vd-operations-bgi-schema.json" and "/call/v1 show bgi " and "show init".(SCGCQ02035551) - Storcli shows incorrect output for delete events command(SCGCQ02045816) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02048150) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053923) - StorCLI displays expansion as successful even when there is no free space to expand(SCGCQ02057361) - Instance Validation Failed between "controller-patrolread-schema.json" and "/call resume patrolread"(SCGCQ02062942) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02063689) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02064120) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02064828) - Aero (DBU PA2): Storcli: Inconsistency in "add vd" command syntax.(SCGCQ02082196) - Details are displayed twice in "/cx/bbu start ? "(SCGCQ02100905) - Storcli: set termlog shows [=on|off] mentioned as optional.(SCGCQ02113353) - CLI is missing the JBOD PD size for SysPDs when using the "show jbod" command(SCGCQ02132277) - Percli returns “invalid arguments" when trying to create a VD using some PDs already configured in a VD and some U(SCGCQ02122169) - Topology information missing from Storcli output(SCGCQ02048612) - (SCGCQ02040597) - Unified StorCLI: StorCLI does not return the return code from SLIT/SLIR3 to explorer/command processors(SCGCQ01925156) - Virtual drive reference in Delete Preserved cache command output(SCGCQ01940333) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940805) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01948579) - Shenandoah : Firmware receives incorrect erase type for sanitize crypto erase option(SCGCQ01958564) - Storcli shows BBU present instead of EnergyPAck in HWcfg for StorCLI /cx show all output.(SCGCQ01985592) - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Sea (3816_Eval) IT Controller(SCGCQ02008219) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for errorcounters commands.(SCGCQ02018078) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02030652) - There is no error message for smart drive failure command.(SCGCQ02040645) - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02046036) - JSON Schema : Updating the schema list with Virtual drive command set(SCGCQ02057360) - storecli_Aero:In linux error message observed in the show output.(SCGCQ02057699) - Checking in JSON schemas(SCGCQ02061305) - Junck character displayed in Virtual SES phy id, when we query phyerror counter for enclosure.(SCGCQ02094970) - Aero (DBU PA3):Storcli: Help of /cx/px reset does not mention about option hard reset.(SCGCQ02100896) - BBU show detailed help does not list "show learn " command.(SCGCQ02100915) - Storcli: Instance Validation Fails for all /call/e65/sall commands where "e65 is not found".(SCGCQ02101564) - Storcli: Remove Nytro supported options in "/cx [start] flush|flushcache [cachecade | ALL]" help.(SCGCQ02113484) - MR7.10 cli return mesg. typo after ctrl restart then immediately running storcli64 /c0 show.(SCGCQ02113833) - Storcli: /c0 compare help lists /c0/px compare command.(SCGCQ02124246) - Serial number not displayed fully in 7.10 StorCLI 007.1017.0000.0000 for IT Controller(SCGCQ02173789) - Hide BBU details from the command "storcli /c0 show alilog" for HPE(SCGCQ01937259) - Disk group is displayed instead of array on HPE platforms(SCGCQ01965366) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02016758) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02024740) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02034471) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02035437) - Instance Validation Failed for "/call show and /call show all".(SCGCQ02101432) - Instance Validation Failed bw "drive-group-detailed-schema.json" and "/call/dall show all".(SCGCQ02101513) - Autoconfig options are allowed to set with latest storcli(SCGCQ02053643) - Unified StorCLI Phase 10 : Image checksum should not be performed for aero images(SCGCQ01942200) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02035439) - Fixing coverity issues Fixing resource leaks and explicit NULL dereferencings(SCGCQ02042242) - Unified StorCLI : Fixing resource leaks - Part 1(SCGCQ02042513) - Updating Schema mapping doc and fixing validation errors (SCGCQ02057434) - Storcli: Instance Validation Fails for vd-bootdrive-schema.json and vd-unmap-schema.json.(SCGCQ02101568) - Aero_storecli:Using latest storecli firmware download fail with noreset option.(SCGCQ02101570) - Aero DBU PA4 : Syntax error is seen for the command - storclio.efi /cx/px set state ?(SCGCQ02113123) - PD info incorrectly shows Number of Blocks for >TB drives(>3TB in my case(SCGCQ02183653) - CLI is returning "success" when attempting to set bios mode to Ignore Errors.(SCGCQ02121017) - On Demand SnapDump does not show proper time stamp.(SCGCQ02084833) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01892288) - Initialize the MFG structure(SCGCQ01901166) - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Aero (3916_Eval) IT Controller(SCGCQ02021194) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02040756) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02042296) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047100) - Updating storcli-cmd-list.xlsx for Drives(SCGCQ02056199) - Message with Incorrect controller object is displayed while setting SSD Caching on VD(SCGCQ02057085) - Storcli displays grammatically incorrect message in detailed help file.(SCGCQ02097641) - MR_7.10: Storcli: Property is shown as SCSI Umap instead of SCSI Unmap.(SCGCQ02101572) - Storcli: /c0 show detailed command does not list /cx/px show phyerrorcounters and /cx show vpd.(SCGCQ02113262) - Aero (DBU PA4):Storcli: Incorrect description of "/c0/v0 show migrate" command.(SCGCQ02113511) - Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) - Storcli: Junk character in PD start locate command description.(SCGCQ02125654) - Storcli doesn't exit with controller status message after doing OFU. (SCGCQ02101069 port of SCGCQ02091548) - perccli /c0 show all lists topology without any DG's present (SCGCQ02085925 port of SCGCQ01998332) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) - Libmods: HPE serial number display(SCGCQ02062634 port of SCGCQ01885657) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) - failure in StorCLI enclosure show status (SCGCQ02043616 port of SCGCQ02040640) - Expander FW download using storecli utility crashs.(SCGCQ01979616 port of SCGCQ01979599) - Hide "set pdfaileventoptions" command from CLI Help(SCGCQ01892551 port of SCGCQ01880722) - Error message when Maximum number of VDs are reached (SCGCQ01911777 port of SCGCQ01856544) - Adding CLI command to display/toggle new controller property.(SCGCQ01927583 port of SCGCQ01106982) - System hangs while creating VD in EFI shell.(SCGCQ01945574 port of SCGCQ01945551) - storclio command not working to update FW on SATA disk(SCGCQ01963953 port of SCGCQ01918814) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01963954 port of SCGCQ01937410) - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964173 port of SCGCQ01955389) - Add security-related compilation and linker flags to StorCLI - Linux (SCGCQ01966163 port of SCGCQ01892560) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations (SCGCQ01982925 port of SCGCQ01979483) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01985486 port of SCGCQ01893074) - Enable iMR advanced debug dump(SCGCQ02035300 port of SCGCQ01873124) - Drive Size Display Miss Match In Storcli Show Output (SCGCQ02074659 port of SCGCQ02072353) - HDET:Libmods-Boot device should be presented as /dev/sda in Linux operating system during installation and post installation (SCGCQ02082198 port of SCGCQ02046182) - HDET: Boot device should be presented as /dev/sda in Linux operating system during installation and post installation(SCGCQ02082199 port of SCGCQ02016712) - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02085669 port of SCGCQ02045967) - storclif /cx delete colinfo ? shows syntax error (SCGCQ02124654 port of SCGCQ02124492) - PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02128167 port of SCGCQ02119004) - Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02142248 port of SCGCQ02140878) - Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02145876 port of SCGCQ02140859) - PERCCLI to support creation of VD with WB policy for PERC8 MR(SCGCQ01892550 port of SCGCQ01891650) - MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+ (SCGCQ02139866 port of SCGCQ02066386) - Libmod changes for SCGCQ02090770(SCGCQ02097658 port of SCGCQ02090770) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) - Drive Size Display Miss Match In Storcli Show Output (SCGCQ02075280 port of SCGCQ02072353) - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) - Storcli help file doesn't show recon rate command instead it shows migrate rate. (SCGCQ02047747 port of SCGCQ02046036) - Storcli shows incorrect output for delete events command(SCGCQ02046875 port of SCGCQ02045816) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations (SCGCQ01979535 port of SCGCQ01979483) - enhance warning message for personality switch indicating interruption could cause controller to be unstable(SCGCQ01892552 port of SCGCQ01892549) - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump" (SCGCQ01906745 port of SCGCQ01889700) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01925211 port of SCGCQ01196785) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929137 port of SCGCQ01224857) - For NVMe drive use the term NVMe instead of PCIe (SCGCQ01963960 port of SCGCQ01923119) - StorCLI show SAS address for NVMe drives (SCGCQ01963964 port of SCGCQ01921258) - JBOD list is not showing in order when using /cx show(SCGCQ01965193 port of SCGCQ01961527) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965209 port of SCGCQ01949495) - supported personalities has blank value (SCGCQ01971366 port of SCGCQ01965370) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977028 port of SCGCQ01948579) - Expander FW download using storecli utility crashs.(SCGCQ01979617 port of SCGCQ01979599) - WBSup abbreviation defined twice when running perccli /cX show profile(SCGCQ01995022 port of SCGCQ01993282) - spell mistake in start diag operation failure(SCGCQ01998963 port of SCGCQ01998330) - Proper message to be given on VD creation with wb option while Battery not connected/Failed(SCGCQ02028787 port of SCGCQ01972504) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02028810 port of SCGCQ02008676) - Enable iMR advanced debug dump(SCGCQ02035289 port of SCGCQ02030908) - On Demand SnapDump does not show proper time stamp.(SCGCQ02085609 port of SCGCQ02084833) - Flashing of Completeflash fails on Sea IT controller(SCGCQ02139848 port of SCGCQ02139780) - Storcli: "Ctrl" legend not mentioned.(SCGCQ02150640 port of SCGCQ02146822) - storcli -help missing the verbose option (SCGCQ02160908 port of SCGCQ02158600) - MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02168183 port of SCGCQ02165933) - Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02179296 port of SCGCQ02174296) - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180519 port of SCGCQ02180495) - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy. (SCGCQ02047079 port of SCGCQ02024740) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) - storcli faults for enclosure show command(SCGCQ01986423 port of SCGCQ01985815) - storclio command not working to update FW on SATA disk(SCGCQ01922919 port of SCGCQ01918814) - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964153 port of SCGCQ01955389) - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01965185 port of SCGCQ01413253) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965210 port of SCGCQ01949503) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01966261 port of SCGCQ01893074) - Add security-related compilation and linker flags to StorCLI - Linux (SCGCQ01985558 port of SCGCQ01892560) - Snapdump unsupported commands for HPE needs to be disabled(SCGCQ01996375 port of SCGCQ01985589) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02009848 port of SCGCQ01992461) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02011417 port of SCGCQ01761309) - StorcliO show oob command fails for Invader based cards(SCGCQ02043788 port of SCGCQ02040783) - Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02124488 port of SCGCQ02123789) - Storcli: "completeflash" is listed in Windows help file.(SCGCQ02145743 port of SCGCQ02141931) - Storcli: /c0 set ? lists bbu,mx,px and lnx commands. (SCGCQ02145756 port of SCGCQ02136689) - Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02145764 port of SCGCQ02136333) - Help note 'page=[x]' needs update(SCGCQ02149062 port of SCGCQ02146823) - Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02153948 port of SCGCQ02150924) - Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02154721 port of SCGCQ02135526) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) - Aero (DBU PA2(SCGCQ02086670 port of SCGCQ02082460) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) - show/set lane speed shows success when we are in SAS profile(SCGCQ02079507 port of SCGCQ02078437) - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all (SCGCQ02047235 port of SCGCQ02040756) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) - Request to Disable DSW3(SCGCQ01903331 port of SCGCQ01896311) - PERCCLI Support for EKMS(SCGCQ01904188 port of SCGCQ01902150) - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01904340 port of SCGCQ01413253) - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921529 port of SCGCQ01220901) - Hide "set termlog" help contents from perccli(SCGCQ01935143 port of SCGCQ01923643) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01940869 port of SCGCQ01937410) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01945534 port of SCGCQ01940805) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01965393 port of SCGCQ01935697) - Storcli shows wrong PD list sequence.(SCGCQ01971632 port of SCGCQ01967488) - LD size not shown in GiB format in foreign import preview(SCGCQ01996370 port of SCGCQ01978978) - Unable to switch to eHBA mode using a H745P Adapter(SCGCQ01998964 port of SCGCQ01990060) - perccli show profile lists personality as JBOD instead of eHBA(SCGCQ01998966 port of SCGCQ01998328) - Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101377 port of SCGCQ02101372) - In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02116733 port of SCGCQ02115036) - complete Lane WWID is not displayed(SCGCQ02145739 port of SCGCQ02145716) - No "Rbld" legend during rebuild. (SCGCQ02150634 port of SCGCQ02146819) - Error message mismatch is seen for rttdump command on iMR Ventura controller.(SCGCQ02160907 port of SCGCQ02156483) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) - Multiple status messages are displayed in the output (SCGCQ02086536 port of SCGCQ02073042) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034200 port of SCGCQ02034064) - Storcli shows wrong PD list sequence.(SCGCQ01977461 port of SCGCQ01967488) - Migrate Failure case is not Branding compliant(SCGCQ02000716 port of SCGCQ01988402) - StorCLI PH12: Retrieving topology details causes application crash in some scenario(SCGCQ02106192 port of SCGCQ02103217) - Support FMP Images in UEFI Version of PERCCli(SCGCQ02116464 port of SCGCQ02078649) - MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02116497 port of SCGCQ02114898) - PH12 PA - StorCLI - 9310-8i IR FW download fails (SCGCQ02121848 port of SCGCQ02121783) - LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02139867 port of SCGCQ02085102) - MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend (SCGCQ02168256 port of SCGCQ02165944) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02079604 port of SCGCQ02018137) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02079597 port of SCGCQ02035437) - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) - Incorrect status displayed for resume copyback command. (SCGCQ02075291 port of SCGCQ02062834) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01929892 port of SCGCQ01106988) - Added new commands from StorCLI(SCGCQ01935296 port of SCGCQ01134166) - For NVMe drive use the term NVMe instead of PCIe (SCGCQ01964024 port of SCGCQ01923119) - securesed autoconfig param should not be present for perccli help(SCGCQ01986879 port of SCGCQ01986831) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032582 port of SCGCQ02029410) - Drives connected to active backplanes not showing the phy info in connector name (SCGCQ02112425 port of SCGCQ02112424) - Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02150630 port of SCGCQ02132024) - Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02153950 port of SCGCQ02150921) - Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02154755 port of SCGCQ02150651) - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) - Port information is not displayed for Vses Backplane (SCGCQ02085875 port of SCGCQ02053070) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC. (SCGCQ02079601 port of SCGCQ01992461) - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) - Storcli: HPE serial number programming and display(SCGCQ02062635 port of SCGCQ01882984) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) - FW flash fails to load the latest image after upgrade downgrade with resetnow option (SCGCQ02046879 port of SCGCQ02035152) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893381 port of SCGCQ01892288) - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01930028 port of SCGCQ01141462) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01936895 port of SCGCQ01935697) - Terminology change from " Data protection" to " Data integrity".(SCGCQ01940807 port of SCGCQ01827339) - Libmods: Terminology change from " Data protection" to " Data integrity".(SCGCQ01943370 port of SCGCQ01827732) - Incorrect colinfo output of Bad block count(SCGCQ01977457 port of SCGCQ01977443) - StorCLI hangs when viewing controller in FreeBSD (MR7.8 is okay(SCGCQ01984543 port of SCGCQ01978824) - Unified StorCLI : Help command of "Get flash" is not shown in generic help syntax(SCGCQ01985472 port of SCGCQ01985463) - StorCLI show output shows Legends as BBU instead of EnergyPack.(SCGCQ01992007 port of SCGCQ01985587) - Aero A0 UTP: StorCLI snapdump command needs to clarify new "On Demand" snapdump option(SCGCQ01995066 port of SCGCQ01993722) - Shenandoah:StorCLI:Right click properties for released binary shown blank.(SCGCQ02000843 port of SCGCQ01988329) - Smart Carrier Enclosure port info shown as "Multuipath"(SCGCQ02008273 port of SCGCQ01992087) - MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json (SCGCQ02116771 port of SCGCQ02112192) - "Storcli /c# set jbod=on" shows success but does nothing (SCGCQ02119067 port of SCGCQ02117219) - Phyreset Fails on IT controllers (SCGCQ02169305 port of SCGCQ02169242) - Storcli stop erase needs an help file update (SCGCQ02169308 port of SCGCQ02168895) - Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02185911 port of SCGCQ02184862) - Storcli connector display not matching with Aero board 9560-16i. (SCGCQ02085681 port of SCGCQ02072448) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) - remove the maxconcurrentpd check from storcli and report fw returned failure (SCGCQ02053931 port of SCGCQ02053910) - PERCCLI Support for EKMS (SCGCQ01904189 port of SCGCQ01903448) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911832 port of SCGCQ01886637) - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915313 port of SCGCQ01222855) - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915315 port of SCGCQ01227144) - perccli /c0 show all lists topology without any DG's present(SCGCQ01998965 port of SCGCQ01998332) - PH12 PA - StorCLI version not getting printed for show file command (SCGCQ02116759 port of SCGCQ02105185) - Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176697 port of SCGCQ02176681) - With IT controller for set or reset with invalid phy is not showing error(SCGCQ02183510 port of SCGCQ02181823) EnhancementRequests: - Incorporating VMware constraints for PERCCLI VIB signing (SCGCQ02190441) - Migrating VMware 64 bit toolchain to 6.8.7-13394445(SCGCQ02190429) - Create an event for DDF config clear failed event.(SCGCQ02173513) - (SCGCQ02162699) - Snap Dump ClearAll Method logging event(SCGCQ02157359) - API changes for a better presentation of Atlas to tools(SCGCQ02149380) - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) - Better error message for certain unmap operations(SCGCQ02111563) - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change(SCGCQ02103973) - MR Windows IOCTL Error codes to Application added to MR API(SCGCQ02103183) - API changes for linkconfig interface (SCGCQ02053671) - API changes for NVMe speed and width changes (SCGCQ02053667) - Reword event log messages as it creates unnecessary panic.(SCGCQ02013675) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949495) - Unified StorCLI : Adding component level download functionality to StorCLI(SCGCQ01940030) - show complete Serial Number and Model Name for NVMe drive(SCGCQ01927541) - snapdump support for host initiated snapdump (SCGCQ01901158) - Changes for disable least latency mode(SCGCQ01891451) - Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01929656) - MR_SAS_Unified_Libmods_7.10 Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01979597) - Post firmware trace buffer at the time of driver load(SCGCQ01992779) - Adding the spare details in the same volume creation(CONFIG_ADD DCMD(SCGCQ02008407) - PSoC implementation in StorCLI by parsing PSoC image(SCGCQ02072160) - Request to display the help for "show" and "set" for JBOD in PercCLI (SCGCQ02160291) - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) - Enable iMR advanced debug dump(SCGCQ02030908) - Unified StorCLI : ARM Windows support to StorCLI(SCGCQ01962294) - Disabling RAID00 support (SCGCQ01960420) - HPE Shenandoah: Branding tool(SCGCQ01960295) - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949503) - Unified StorCLI : Allow SBR/SPD read and write using new CBB+SBR concatenated image(SCGCQ01927551) - show complete Serial Number and Model Name for NVMe drive connected to IT controller(SCGCQ01927538) - show complete Serial Number and Model Name for NVMe drive(SCGCQ01919655) - Unified CLI - Command processor changes for handling invalid/tampered device id's for sea IT controllers(SCGCQ01891513) - Add support to display PSOC version for Ventura IT controllers(SCGCQ02067300) - set copyback command changes for cli(SCGCQ02148092) - Unified StorCLI : ARM64 Windows support to StorCLI - LibMod changes(SCGCQ01963208) - Shenandoah: Adding support bit check for delete snap dump(SCGCQ01944500) - Enable iMR advanced debug dump(SCGCQ01873124) - Unified StorCLI : PSoC read and write via Device read and write DCMD's in MR Operational case(SCGCQ01949521) - Changes for disable least latency mode(SCGCQ01891442) - Adding the spare details in the same volume creation (CONFIG_ADD DCMD(SCGCQ02008403) - Unified StorCLI : Allow erase functionality on operational MR using CBB concatenated image(SCGCQ01927595) - Unified CLI : Handling invalid/tampered controllers for sea controllers(SCGCQ01891484) - Requesting StorCLIF to read MR FW from flash device and write it to a file. Similar to what IT FW support.(SCGCQ01631948) - Add ability to field upgrade PSOC on HBA boards(SCGCQ01583214) - DUal Image SUpport(SCGCQ01960287) - Libmods: Porting HPE Shenandoah from Aero to 7.9 (SCGCQ01917263) - Porting HPE Shenandoah from Aero to 7.9(SCGCQ01917172) - Adding HPE specific help for storcli (SCGCQ01935699) 007.0816.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- defects: - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01824574 port of SCGCQ01824569) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01827604 port of SCGCQ01681538) - Updating makefile and EFI's INF changes for ARM StorCLIO(SCGCQ01870684 port of SCGCQ01563125) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) - failure in StorCLI enclosure show status (SCGCQ02043616 port of SCGCQ02040640) - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) - perccli /c0 show all lists topology without any DG's present(SCGCQ02085925 port of SCGCQ01998332) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853370 port of SCGCQ01775616) - (SCGCQ01775602 port of SCGCQ01814011) - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) - Storcli shows incorrect output for delete events command (SCGCQ02046875 port of SCGCQ02045816) - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02047747 port of SCGCQ02046036) - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) - Drive Size Display Miss Match In Storcli Show Output(SCGCQ02075280 port of SCGCQ02072353) - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) - Libmod changes for SCGCQ02090770 (SCGCQ02097658 port of SCGCQ02096774) - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01850374 port of SCGCQ01837932) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02047079 port of SCGCQ02024740) - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02047235 port of SCGCQ02040756) - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) - show/set lane speed shows success when we are in SAS profile (SCGCQ02079507 port of SCGCQ02078437) - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) - Aero (DBU PA2)(SCGCQ02086670 port of SCGCQ02082460) - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) - Error message when Maximum number of VDs are reached (SCGCQ01857450 port of SCGCQ01856544) - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #" (SCGCQ02034200 port of SCGCQ02034064) - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) - Multiple status messages are displayed in the output (SCGCQ02086536 port of SCGCQ02073042) - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01825986 port of SCGCQ01824570) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01832791 port of SCGCQ01816927) - Add interface in storecli that could get relearn complete status (SCGCQ01850373 port of SCGCQ01848387) - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/ eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) - Incorrect status displayed for resume copyback command.(SCGCQ02075291 port of SCGCQ02062834) - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread" (SCGCQ02079597 port of SCGCQ02035437) - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/ px commands.(SCGCQ02079604 port of SCGCQ02018137) - Aero - LibMod changes for ER SCGCQ01813156 : Addition of Aero and Sea device id's and checkwords (SCGCQ01853418 port of SCGCQ01813626) - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) - FW flash fails to load the latest image after upgrade downgrade with resetnow option (SCGCQ02046879 port of SCGCQ02035152) - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02079601 port of SCGCQ01992461) - Port information is not displayed for Vses Backplane (SCGCQ02085875 port of SCGCQ02053070) - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) - Add get VPD command support to StorCLI in OS environment (SCGCQ01855067 port of SCGCQ01852603) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) - CSET: Checking in Libmod changes for defect SCGCQ02030652 - (SCGCQ02045948(SCGCQ02047884 port of ) - remove the maxconcurrentpd check from storcli and report fw returned failure (SCGCQ02053931 port of SCGCQ02053910) - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02085681 port of SCGCQ02072448) EnhancementRequest: - Updating ncurses library from 6.0 to 6.1(SCGCQ01836749) - Command processor changes for Secure boot properties feature - SCGCQ01855473 (SCGCQ01855503) - Adding secure boot properties to unified StorCLI (SCGCQ01855473) - Adding new MFI STAT - MFI_STAT_SECURE_BOOT_KEY_SLOTS_FULL 007.0711.0000.0000 for Lenovo(SCGCQ01865190) 007.0713.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) - storcli controller show all lists EPD's in VD list(SCGCQ01556595) - controller show all command is not listing the Battery information(SCGCQ01561689) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) - Spell mistake in error message for hwdev command(SCGCQ01614972) - Coverity defect fix for itctflash file(SCGCQ01616369) - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) - Help content for jbodx show unmap is not present(SCGCQ01790130) - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) - storclio command not working to update FW on SATA disk(SCGCQ01918814) - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) - Checking in VBAS compliation changes(SCGCQ01630324) - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) - Space need in the output for secure erase(SCGCQ01713604) - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) - Storcli does not display the complete enclosure serial number(SCGCQ01735493) - Storcli vib update fails across releases.(SCGCQ01761795) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) - Removing the set/show of unmap on JBOD.(SCGCQ01817855) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) - CLI does not report Serial number for Enclosure.(SCGCQ01595640) - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) - Update help contents for jbod delete(SCGCQ01624605) - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) - Missing punctuation in Perccli delete config message(SCGCQ01698226) - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) - Drive Fw download Coverity fixes(SCGCQ01615074) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) - Updating the Diag results as per new API changes(SCGCQ01537255) - Resource leaks,Uninitialized variables(SCGCQ01600311) - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) - Removal of ncurses references for linux makefile(SCGCQ01955544) - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) - .(SCGCQ01571935 port of SCGCQ01325052) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) EnhancementRequests - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) - Enhance StorCLI show file= to include PnP ID(SCGCQ01517431) - Need Storcli support drive FW upgrade(SCGCQ01583217) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) - MR API changes to support EKMS over OOB(SCGCQ01874035) - Add new error code for tampered or invalid controller(SCGCQ01885686) - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) - Add secure boot key update complete event(SCGCQ01928254) - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) - Add a bit for atomic descriptor capable(SCGCQ01965047) - Add Downgrade Firmware function in Storcli(SCGCQ01583223) - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 007.0525.0000.0000 - Moderate Impact/Low Probability of Occurrence -------------------- Defects (16) -.(SCGCQ01753405) - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) - Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315) - Enclosure show status command gives success but nothing is shown.(SCGCQ01731280) - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927) - Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612) - Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548) - Space need in the output for secure erase.(SCGCQ01713604) - seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619) - Missing punctuation in Perccli delete config message.(SCGCQ01698226) - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) - WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279) - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444) - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355) - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816) - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795) - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) - Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493) - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849) - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269) - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) - controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704) - Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749) - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356) - Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493) - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354) - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418) - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616) - Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223) - Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972) - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602) - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983) EnhancementRequests (30) - API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266) - RTTrace Enable/Disable API changes.(SCGCQ01830211) - Criteo: API changes reversal.(SCGCQ01760512) - RTTrace API Changes.(SCGCQ01745568) - API changes needed to support eHBA product series.(SCGCQ01727346) - Create sanitize events.(SCGCQ01713708) - MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730) -.(SCGCQ01593479) -.(SCGCQ01761309) - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538) - API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667) - Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538) - Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062) - Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153) - Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319) - Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724) -.(SCGCQ01818580) - Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135) - API change to provide learn complete timestamp.(SCGCQ01845269) - Added Support for Triggering SnapDump.(SCGCQ01848759) - Add secure boot support.(SCGCQ01792416) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487) - Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424) - Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686) - [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480) - Added new events for unmap policy changes.(SCGCQ01871912) - MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021) - API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150) - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528) - Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603) 0007.0507.0000.0000-1 - Moderate Impact/Low Probability of Occurrence ------------------- Defects (75) - Profile Mgmt API Changes.( SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing.(SCGCQ00948535) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835) - 800C error when execting Get MFC default function.(SCGCQ01037840) - Enable WB support via API.(SCGCQ01405242) - Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458) - Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920) - Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979) - Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940) - storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171) - Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396) - Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401) - Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745) - Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131) - Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420) - Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852) - Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910) - Detailed help contents were not present for most of the IT download options..(SCGCQ01483760) - Spelling errors in the "/cx restart" command..(SCGCQ01486415) - Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052) - CLI help does not reflect the new command to create an ePD.(SCGCQ01639583) - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964) - Instance Validation is failing for mentioned commands..(SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447) - Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990) - PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588) - Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580) - Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146) - Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694) - PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920) - PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062) - Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041) - Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421) - Checking in VBAS compliation changes.(SCGCQ01630324) - PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798) - Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240) - Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237) - Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214) - MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234) - Adding excludevd option to the help file of patrolread command.(SCGCQ01443435) - PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582) - Schema addition for "show file= " command.(SCGCQ01461209) - PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593) - MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562) - PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762) - Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845) - Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344) - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) - OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785) - Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797) - Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754) - Incorrect help description for erase and download completeflash commands.(SCGCQ01470263) - Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802) - Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833) - Check for supported pages for firing drive SCSI commands.(SCGCQ01474325) - No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900) - IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753) - Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595) - DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683) - Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446) - Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195) - Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334) - Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766) - Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821) - UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749) EnhancementRequests (174) - MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167) - New fault code for routine synchronous reset.(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613) - Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177) - New configuration params added for EPD-PT devices.(SCGCQ01599607) - MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347) - Implement Snapdump debugging capability.(SCGCQ01567770) - Add "Incompatible with Profile" event.(SCGCQ01289924) - API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700) - API change for Simplified RAID10 Creation.(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969) - MPI 2.5: Add new connector types.(SCGCQ01085073) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208) - MPI 2.5: update copyright info.(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175) - Add type BIOS for HashImageType..(SCGCQ00566306) - Identify physical location of a target device.(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293) - MPI 2.5: Signed images for FWDownload.(SCGCQ00469990) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437) - MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512) - Allow Protection Information bit for IR Volume Create.(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request.(SCGCQ00264755) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487) - JSON schema for Drive level commands.(SCGCQ01445435) - MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request.(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272) - MPI 2.6: Enclosure Management.(SCGCQ00345273) - Device Info field for PCIe devices.(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields.(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600) - Modified address space bits.(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563) - MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support.(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541) - MPI 2.6: System Interface Register Set update.(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869) - MPI 2.6: Add new FLASH region types.(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527) - MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088) - MPI 2.6: add PCI Device ID's.(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827) - MPI 2.6: Update Flash Signature..(SCGCQ00852831) - profile management API.(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328) -.(SCGCQ00878757) - Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262) - MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336) - MPI 2.6: Remove all SOP references.(SCGCQ00925839) - Ventura: de-feature AHCI.(SCGCQ00941620) - MPI 2.6: Remove all AHCI references.(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619) -.(SCGCQ00987840) - MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741) - mega api changes for ibuttonless PR.(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821) -.(SCGCQ01082303) -.(SCGCQ01085954) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127) - MPI 2.6: Add new clean tool options.(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267) - Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848) - MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005) - MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760) - MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864) - MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008) -.(SCGCQ01389581) - MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498) - MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515) - Add Test Link Diagnostic API.(SCGCQ01436268) - Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048) - MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138) - Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245) - Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149) - Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045) - Add support for API fields to report SED type of PD.(SCGCQ01587230) - Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520) - NVDATA parameter to OPAL SED.(SCGCQ01614689) - Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350) - Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135) - Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234) - Add support to defeature Cached I/O policy.(SCGCQ01581032) - New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819) - Removing the NMR storcli commands from storcli..(SCGCQ01445268) - Add support to allow Device names greater than 107.(SCGCQ01039328) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213) - MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256) - Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176) - Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628) - Removing the NMR storcli commands from storcli..(SCGCQ01445418) -.(SCGCQ01428114) -.(SCGCQ01423509) - Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987) - Add NVMe device related changes.(SCGCQ01034678) - Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986) - Add boot drive selection support in Stor-CLI.(SCGCQ01445896) - Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424) -.(SCGCQ01466805) - StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954) - StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799) - Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308) - Add support for IT Firmware images and IT Completeflash images to "show file= " command.(SCGCQ01436882) CSETActivities (57) - StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445) - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) - Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483) - Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457) - Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170) - Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237) - SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030) - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) - This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717) - Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154) - Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920) - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698) - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) - Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154) - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) - Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709) - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) - Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764) - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) - Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526) - Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435) - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) - SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453) - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412) - Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234) - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) - Commands "/call/ all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) - Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628) - Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447) - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) - Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900) - DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749) - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) - Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460) - Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460) - Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156) - Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214) - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793) - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) - Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754) 0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence ------------------- fixes: - Profile Mgmt API Changes.(SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing.(SCGCQ00948535) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835) - 800C error when execting Get MFC default function.(SCGCQ01037840) - StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715) - PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728) - Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846) - Fixing Error Handling issues and Resource leak.(SCGCQ01319395) - Fix for Libmod files having potential loop errors.(SCGCQ01320336) - Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003) - EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452) - Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604) - Updated the Help.(SCGCQ01375059) - controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816) - Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238) - storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690) - Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373) - storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425) - Fixing out of bounds in libmods.(SCGCQ01385430) - StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177) - Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543) - PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511) - Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756) - Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011) - Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017) - Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239) - Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875) - Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458) - Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920) - PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897) - Need to handle FW return code change for profile management success case.(SCGCQ01307320) - Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405) - PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477) - Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749) - CLI reports failure when issuie DPM commands.(SCGCQ01333085) - PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041) - Fixing unchecked return values.(SCGCQ01385377) - Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610) - Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922) - LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583) - Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764) - Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948) - Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222) - This is a syntactical error where a comma was added.(SCGCQ01414744) - Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208) - Instance Validation is failing for mentioned commands.(SCGCQ01415355) - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216) - StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460) - Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018) - IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046) - Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219) - Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438) - Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534) - Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771) - Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261) - Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237) - Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214) - Adding excludevd option to the help file of patrolread command.(SCGCQ01443435) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381) - PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757) - Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407) - Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042) - CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639) - Removing the memory leaks in dequelog command.(SCGCQ01411544) - Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758) - Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934) - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306) - Fixing Out of Bounds access and Resource leak.(SCGCQ01304875) - Inconsistencies between the applications for manage link speed.(SCGCQ01389856) - Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106) - Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263) - Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754) - StorCLI: Spindown help syntax is misleading.(SCGCQ01421610) - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355) - StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149) - Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900) - Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891) - Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748) - Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255) - DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683) - Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890) - Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943) - Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018) - Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024) - storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289) - StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557) - Removing the NMR command for setting SCAPVPD.(SCGCQ01389451) - Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938) - Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749) EnhancementRequests: - MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167) - New fault code for routine synchronous reset.(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613) - API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700) - API change for Simplified RAID10 Creation.(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969) - MPI 2.5: Add new connector types.(SCGCQ01085073) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208) - MPI 2.5: update copyright info.(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175) - Add type BIOS for HashImageType.(SCGCQ00566306) - Identify physical location of a target device.(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293) - MPI 2.5: Signed images for FWDownload.(SCGCQ00469990) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437) - MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512) - Allow Protection Information bit for IR Volume Create.(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request.(SCGCQ00264755) -.(SCGCQ01421997) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793) - RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354) - Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469) - Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465) - List pending profile details of the controller.(SCGCQ01346308) -.(SCGCQ01291037) - MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request.(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272) - MPI 2.6: Enclosure Management.(SCGCQ00345273) - Device Info field for PCIe devices.(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields.(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600) - Modified address space bits.(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563) - MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support.(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541) - MPI 2.6: System Interface Register Set update.(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869) - MPI 2.6: Add new FLASH region types.(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527) - MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088) - MPI 2.6: add PCI Device ID's.(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827) - MPI 2.6: Update Flash Signature..(SCGCQ00852831) - profile management API.(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328) -.(SCGCQ00878757) - Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262) - MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336) - MPI 2.6: Remove all SOP references.(SCGCQ00925839) - Ventura: de-feature AHCI.(SCGCQ00941620) - MPI 2.6: Remove all AHCI references.(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619) -.(SCGCQ00987840) - MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741) - mega api changes for ibuttonless PR.(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821) -.(SCGCQ01082303) -.(SCGCQ01085954) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127) - MPI 2.6: Add new clean tool options.(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267) - MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819) - always print StorCLI version information at beginning/top of output.(SCGCQ01396733) - StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177) - New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429) - Add support to allow Device names greater than 107.(SCGCQ01039328) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213) - Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628) -.(SCGCQ01428114) - Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646) - Add NVMe device related changes.(SCGCQ01034678) - Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301) - Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079) - Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495) CSETActivities: - StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339) - Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018) - MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993) - The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216) - Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830) - Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790) - MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315) - MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798) - Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785) - SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030) - Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496) - Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485) - ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651) - Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610) - Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565) - Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900) - CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 ) - Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789) - Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152) - Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673) - Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381) - Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320) - MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757) - perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596) - Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529) - Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529) - MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520) - Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274) - MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298) - SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940) - StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843) - Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891) - CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958) - The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 ) - perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993) - StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177) - Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604) - Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294) - StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843) - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152) - C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488) - Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830) - Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721) - Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993) - ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651) - storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495) - Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145) - Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484) - [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914) - Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309) - Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846) - PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728) - MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756) - MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493) 0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence ------------------- Fixes: - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536) - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913) - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948) - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629) - Code clean up in libmods and sysefi files are added(SCGCQ00359998) - Storcli is returning error with show(SCGCQ00360040) - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814) - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216) - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717) - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455) - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522) - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097) - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248) - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622) - UEFI, the O/P of "Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735) - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000) - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155) - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735) - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364) - portings of AdpRestart command(SCGCQ00378135) - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828) - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104) - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303) - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789) - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832) - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350) - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610) - SWR_1.34(SCGCQ00442652) - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502) - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583) - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843) - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560) - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201) - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579) - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935) - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835) - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123) - Storcli : unable to set patrol read delay(SCGCQ00645195) - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324) - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742) - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131) - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171) - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505) - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647) - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770) - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178) - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183) - Adapters are not listed in sorted order.(SCGCQ00759969) - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398) - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752) - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663) - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712) - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762) - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243) - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789) - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882) - "cpybck" help is not coming in Legends(SCGCQ00784808) - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400) - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232) - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374) - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394) - .(SCGCQ00800878) - Deallocation of the same memory more than once(SCGCQ00802031) - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588) - Out-of-bounds access and array delete misuse(SCGCQ00804680) - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547) - Not able add new VD in Drive Group(SCGCQ00813314) - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939) - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049) - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299) - storcli /call show all fails with "command invalid"(SCGCQ00830269) - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342) - Profile Mgmt API Changes(SCGCQ00883008) - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738) - The code had events with repetitive ID and some structures clashing(SCGCQ00948535) - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835) - 800C error when execting Get MFC default function(SCGCQ01037840) - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936) - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284) - No ISE Capable field(SCGCQ01148693) - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175) - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698) - Fixing Resource leaks(SCGCQ01205356) - resource validation before de referencing(SCGCQ01206104) - Fixing resource leaks in libmods(SCGCQ01208044) - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393) - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414) - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473) - Fix for resource leak in system config show(SCGCQ01210133) - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415) - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383) - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923) - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217) - NVMe PD SMART DATA shows all 0's(SCGCQ01236052) - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715) - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381) - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687) - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688) - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928) - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421) - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632) - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445) - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336) - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979) - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883) - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094) - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474) - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620) - Some sparc structures missing for storcli.(SCGCQ00504585) - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761) - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658) - storecli reports wrong size on 3000MB VD(SCGCQ00644545) - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962) - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672) - Add support bits for uneven-span and SSHA support(SCGCQ00755063) - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101) - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924) - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290) - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959) - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385) - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937) - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658) - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714) - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759) - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347) - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363) - Storcli errors are printing in a different line.(SCGCQ00771626) - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302) - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332) - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577) - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800) - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357) - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202) - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761) - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393) - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335) - Resource leak(SCGCQ00804745) - .(SCGCQ00811452) - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672) - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205) - Fix for profile management support check bit(SCGCQ01208103) - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411) - Unified Storcli: Fixing resource leak issues(SCGCQ01209413) - SAS3.5 Ventura(SCGCQ01219196) - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153) - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169) - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376) - Need to handle FW return code change for profile management success case(SCGCQ01307320) - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263) - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644) - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663) - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978) - storcli /c0 show is not listinf SWR controller(SCGCQ00454971) - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116) - Raptor Galaxy : Storcli(SCGCQ00475562) - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981) - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771) - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763) - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073) - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800) - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416) - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775) - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174) - storelib header file changes porting(SCGCQ00609942) - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023) - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969) - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070) - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000) - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187) - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806) - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918) - Missing the Display of the property temperatureCtrl.(SCGCQ00792264) - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760) - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336) - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206) - Memory not freed which can cause leak(SCGCQ00804554) - Varailble need to be freed before returning in all failure case(SCGCQ00804650) - IDA show incorrect RAID controller type information(SCGCQ00806966) - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197) - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372) - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111) - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464) - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723) - Removing Unused and logically dead code in storcli(SCGCQ01204045) - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492) - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685) - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083) - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216) - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332) - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100) - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043) - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956) - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370) - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287) - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672) - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181) - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862) - CPLD(SCGCQ00787705) - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233) - rlListPtr is not handled properly in failure case(SCGCQ00796227) - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392) - LDViewMirror is giving segmentation fault(SCGCQ00830435) - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758) - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321) - Checking in compilation error for Libmods(SCGCQ00919973) - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356) - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055) - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407) - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101) - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553) - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381) - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709) - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745) - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950) - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070) - debug prints are present when issuing /co/eall show(SCGCQ00475815) - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543) - Verify StorCLI warns on destructive operations(SCGCQ00712982) - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584) - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691) - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358) - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200) - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211) - Incorrect sizeof expression in dcmdprm(SCGCQ00793354) - Non-array delete for objects in rmdatamf(SCGCQ00793361) - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420) - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663) - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672) - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736) - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583) - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096) - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306) - PD related information missing for NVMe drives(SCGCQ01126564) - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365) - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854) - StorCLI(SCGCQ01274554) - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911) - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070) - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665) - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107) - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008) - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605) - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355) - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402) - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205) - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334) - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342) - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311) - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117) - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368) - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844) - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353) - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082) - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437) - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721) - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236) - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289) - Help for Compare linkspeed is not complete(SCGCQ01275454) - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037) - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491) - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067) - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426) - Libmod changes to support profile management(SCGCQ01048228) - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627) - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876) - Ventura PH3(SCGCQ01253012) - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455) - coverity removing out of bounds reads from code(SCGCQ01280460) - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999) - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085) - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234) - Resource leak in VdDataMf scanPartitions(SCGCQ00793363) - Storcli can't create AHCI LDs(SCGCQ00897637) - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676) - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024) - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214) - Detailed help missing for IT erase commands(SCGCQ01275474) - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671) - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453) Enhancement - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167) - New fault code for routine synchronous reset(SCGCQ01264142) - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358) - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050) - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414) - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228) - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796) - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215) - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613) - API changes for CR55(SCGCQ01222700) - API change for Simplified RAID10 Creation(SCGCQ01222698) - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406) - API changes for PR SCGCQ01139678(SCGCQ01215334) - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028) - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954) - API changes for PR SCGCQ01127742(SCGCQ01203751) - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886) - MR 6.12(SCGCQ01146597) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627) - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969) - MPI 2.5: Add new connector types(SCGCQ01085073) - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162) - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885) - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208) - MPI 2.5: update copyright info(SCGCQ00728066) - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820) - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175) - Add type BIOS for HashImageType.(SCGCQ00566306) - Identify physical location of a target device(SCGCQ00523879) - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817) - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293) - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819) - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437) - Allow Protection Information bit for IR Volume Create(SCGCQ00385306) - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551) - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271) - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270) - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266) - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260) - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506) - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383) - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439) - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131) - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055) - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759) - MPI 2.6: SOP Encapsulated request(SCGCQ00264755) - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183) - Libmods changes for EFI support for Unified storcli(SCGCQ00923719) - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101) - OEL Support for SPARC(SCGCQ00787923) - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010) - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007) - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477) - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399) - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735) - MPI 2.6: add IO Unit Control Request(SCGCQ00345258) - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272) - MPI 2.6: Enclosure Management(SCGCQ00345273) - Device Info field for PCIe devices(SCGCQ00353339) - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843) - MPI 2.6: new family values for ProductID fields(SCGCQ00360952) - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600) - Modified address space bits(SCGCQ00397136) - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563) - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568) - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572) - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577) - MPI 2.6: Add NVMe SGL support(SCGCQ00398256) - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541) - MPI 2.6: System Interface Register Set update(SCGCQ00464402) - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292) - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998) - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281) - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070) - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869) - MPI 2.6: Add new FLASH region types(SCGCQ00619371) - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271) - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957) - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527) - MPI 2.6: Extend Task Management(SCGCQ00686666) - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177) - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600) - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389) - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088) - MPI 2.6: add PCI Device ID's(SCGCQ00828497) - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588) - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827) - MPI 2.6: Update Flash Signature.(SCGCQ00852831) - profile management API(SCGCQ00867953) - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169) - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328) - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262) - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740) - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256) - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336) - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213) - MPI 2.6: Remove all SOP references(SCGCQ00925839) - Change library name to SLIT(SCGCQ00933175) - Ventura: de-feature AHCI(SCGCQ00941620) - MPI 2.6: Remove all AHCI references(SCGCQ00948258) - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955) - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638) - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619) - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104) - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930) - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826) - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027) - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687) - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473) - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741) - mega api changes for ibuttonless PR(SCGCQ01059740) - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009) - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374) - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821) - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549) - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839) - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127) - MPI 2.6: Add new clean tool options(SCGCQ01141732) - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092) - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267) - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005) - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367) - MPI 2.5: Signed images for FWDownload(SCGCQ00469990) - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512) - Display the Storelib version in the show command.(SCGCQ01286063) - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457) - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496) - Add support to allow Device names greater than 107(SCGCQ01039328) - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636) - Enable SED on JBOD(SCGCQ00755527) - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230) - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051) - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474) - Implemented the diag results to print on console(SCGCQ00525321) - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742) - MWCLI. Add HA support into storcli(SCGCQ00352120) - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668) - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607) - Add NVMe device related changes(SCGCQ01034678) - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665) - Complete 240VD support for utilities(SCGCQ00693042) - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287) - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311) - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793) - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715) - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821) - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146) - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204) - UDK Support for EFI(SCGCQ00795150) - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171) - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872) - Provide a way to enable or disable 512E using Applications(SCGCQ00351234) - Refer attached design doc(SCGCQ00349599) - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495) - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050) - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217) - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344) - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473) - RRB 71(SCGCQ00750164) - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081) - SED/FDE changes for storcli Synchro(SCGCQ00632240) - ASD- StorCLI(SCGCQ00467863) - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209) - PERC 10 WIndows Support(SCGCQ01213160) - PERC 10 WIndows Support(SCGCQ01213157) - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080) - Megacli/storcli support for lmrc driver(SCGCQ00433703) - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093) - Uneven span support is added in StorCLI.(SCGCQ00349548) - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391) - Add EFI support for the manufacturing command to program.(SCGCQ01191095) - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216) - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476) - Monitoring Drive performance and predictive failure(SCGCQ00817977) - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118) - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237) - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987) - Functionality to extract field value from new API changes(SCGCQ00794841) - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815) 0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence ------------------- Enhancement: - Added support for ThinkSystem HBA and RAID. 1.20.20 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227) - Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335) - Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866) - Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811) - Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074) - Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438) - Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663) - Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140) - Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401) - Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258) - Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358) - Fixed an issue where storcli does not display description on command success - (SCGCQ01023973) - Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081) - Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945) - Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534) - Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430) - Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535) - Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218) - Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102) - Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484) - Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534) - Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745) - Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757) - Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895) - Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068) - Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105) - Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314) - Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646) - Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899) - Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101) - Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120) - Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669) - Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997) - Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082) - Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011) - Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071) - Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117) - Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416) - Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387) - Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154) - Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907) - Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447) - Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139) - Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493) - Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500) - Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028) - Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669) - Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536) - Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554) - Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode - (SCGCQ01043063) - Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322) - Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608) - Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994) - Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298) - Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300) - Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088) - Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805) - Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035) - Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084) - Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706) - Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613) - Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775) - Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973) - Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830) - Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940) - Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786) - Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464) - Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466) - Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876) - Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415) - Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985) - Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968) - Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027) - Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756) - Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306) - Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841) - Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876) - Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525) - Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798) - Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620) - Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204) - Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274) - Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667) - Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604) - Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055) - Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533) - Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614) - Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474) - Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758) - Fixed an issue where some commands may not report success on success - (SCGCQ01050695) - Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241) - Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116) - Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773) - Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500) - Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378) - Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493) - Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205) - Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864) - Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540) - Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766) - Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178) - Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305) - Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482) - Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514) - Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493) - Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642) - Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528) - Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477) - Fixed an issue where installaton of storclio may fail - (SCGCQ00952422) - Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981) - Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790) - Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315) - Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178) - Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865) - Fixed an issue where EPD details may not show in "show all" command - (SCGCQ00921937) - Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624) - Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489) - Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330) - Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837) - Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484) - Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697) - Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461) - Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597) - Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760) - Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891) - Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993) - Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617) - Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault" - (SCGCQ01020010, Port of SCGCQ01019547) - Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212) - Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145) - Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101) - Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181) - Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177) - Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789) - Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable - (SCGCQ01143941, Port of SCGCQ01026187) - Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307) - Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download - (SCGCQ01110108, Port of SCGCQ00934755) - Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211) - Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584) Enhancements: - Added the personality change command was not present - (SCGCQ00850610) - Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220) - Added multipath support in EPD configuration options - (SCGCQ01015758) - Added additional CPU support on EFI platform - (SCGCQ01026250) - Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304) - Added personality change features - (SCGCQ01111930) - Added VF-queue depth mode settings - (SCGCQ00907072) - Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320) - Added Secure Erase support to JBOD and System drives - (SCGCQ00929757) - Added a JBOD entity for various operations - (SCGCQ01047229) - Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064) - Added more specific error messages in some circumstances - (SCGCQ00920034) - Added new compilation environment and makefiles - (SCGCQ00920058) - Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739) - Added support for drive microcode update Modes E and F - (SCGCQ01047223) - Added code to display JBOD personality - (SCGCQ01146775) - Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338) - Added new erase type called Crypto - (SCGCQ01050618) - Added new command to set the multiInit EPD parameter - (SCGCQ01080273) - Added support for drive microcode update through parallel loading - (SCGCQ01024964) - Added support for EPD creation - (SCGCQ00887664) - Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414) 1.18.11 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705) - Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785) - Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612) - Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196) - Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339) - Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620) Enhancements: - Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662) - Added the support to set and clear the transport on a DG (SCGCQ00920046) - Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318) - Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795) - Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030) - Provide a more descriptive port enumeration (SCGCQ00854620) - Add support to enable/Disable of Large IO Support (SCGCQ00894644) 1.16.14 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617) - Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176) - Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715) - Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755) 1.16.10 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617) - Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470) - Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914) - Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143) - Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429) - Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770) 1.14.12 - Moderate Impact/Low Probability of Occurrence ------- Fixes: - Incorporated StorCLI MegaRAID 6.6 stream Enhancements: - Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171) - Added consistent sorting of controllers using bus, device, function (SCGCQ00696872) - Added ability to enable or disable 512e support (SCGCQ00351234) - Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527) - Added ability for VMWare version to be run from any directory (SCGCQ00642230) - Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477) - Added ability to create a RAID00 (SCGCQ00350668) - Added ability to display the Patrol Read Start Time (SCGCQ00564474) - Added learn cycle progress information in show learn command (SCGCQ00644984) - Added support for uneven spans (SCGCQ00349548) - Added support for lmrc driver (SCGCQ00433703) - Added 240 Virtual Drive support (SCGCQ00693042) - Improved Punctured Block logging (SCGCQ00342399) 1.12.15 - Moderate Impact/Low Probability of Occurrence ------- Fix(es): - Prevent storCLI from allowing users to enable JBOD mode on controllers that do not support JBOD mode. - Updated CACHEBYPASS command to line up with user expectation. When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass. 1.07.07 - Moderate Impact/Low Probability of Occurrence ------- Enhancement(s) - Added support for ServeRAID M1215 SAS/SATA Controller Fix(es): - Fixed an issue where segmentation faults may occur in Linux. - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS. - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying. 1.04.07 - Moderate Impact/Low Probability of Occurrence ------- Enhancement(s) - Added support for ServeRAID M5210e and ServeRAID M5210 Fix(es): - Fixed an issue where a command failure results in subsequent commands and actions failing. - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR. - Added help file for for storcli /cx/dx set security - Fixed an issue where the "show ctrlcount help" command is not displaying properly. - Fixed an issue where a failure is displayed in the output for querying dimmer switch information. - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM. - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives. - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed. - Synced the pause pr command with show pr command to show correct PR Current State. - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property. 1.03.11 - Initial release -------
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |