Lenovo YUM Repository
Release and Change History
Bundle Release Information: |
Targeted Server Family (Machine Type): ThinkSystem ST58 V3 Server (7DF5) |
Targeted Operating System: RHEL8.10 |
YUM Repository Build Date: 2024_12_17 |
Device: |
ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 Feature Code: na |
||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x00A1 |
Release History: |
Continued Support in Owasco - Latest Release | Change History Documents |
Release ST45V3 Change History Documents |
=========================================================================== Intel v28.2 Network FW Update Release for Windows Release date = 08/01/2023 Package Version: net-9.30-6.20-1.3450 =========================================================================== CONTENTS ________ 1.0 Change history 2.0 Web information and support phone Number 3.0 Notices and trademarks 4.0 Disclaimer 1.0 Change history ___________________ This release includes the following updates: ============================================ Versions: 1) The following adapters are ONLY for Option ROM ------------------------------------------------------------------------------------------------ Device Boot ROM (Option ROM) Firmware (Etrack ID) ------------------------------------------------------------------------------------------------ I350 1.3450 NA 2) NVMUPDATE tool updated to 1.39.71.0 to support new config version. This update supports Lenovo ThinkSystem and ThinkAgile products. Important Note: If you choose to install the nvmupdate64e utility manually, please ensure that you install version 1.39.71.0 or newer. Earlier versions of nvmupdate64e tool may not be not compatible or include all latest supported features. New features: - IPS: 00699338 - Name of I350 interlock in XCC is inconsistent with V1 Description: Card Name field shall be taken from V1 VPD field instead of "large resource string". This change applies to 1G Lenovo devices with enabled AIM support and existing V1 VPD field. Release net-9.2-6.2-1.3357.0 includes the following updates: ============================================================== New features: - Defines the IID (Instance IDs) field in the NC-SI packet's header, which is used to match responses to requests and to differentiate between new and retried commands. Description: According to the spec, If the IID of the current command is the same as the previous command's IID, the command is a "Retried Command" and the FW shall return the response of previous command (should be done without re-executing the command). When the IID is different than from the previous command, the command is executed. The NC-SI spec is unclear on if the incoming commands IID is compared to the IID of the previous command received on the same channel, package or device. This feature defines a transfer to maintaining a single buffer for the last NC-SI command received on the device per transmitting interface. Bug fixes: - Link Status Change AEN event is not send after link down Description: Sending AEN Enable command with Link Status Change equals true, then sending Port Control Command with Port Control field equals 0x0 - disable. There is no event after link down. Fix: Changed event rejection condition to response. - After running reboot 123 times with qtest, slot4 (X710-T2L) shows an error Description: Used qtest ro run reboot 123 times, xcc web appears: PCIe Correctable Error Threshold limit has been exceeded at Segment 0x0000 Bus 0xA8 Device 0x00 Function 0x01. Fix: Adjust the replay timer timeout value for different scenarios. Release net-9.0-6.0-1.3266.0 includes the following updates: ============================================================== New features: - Windows 10,11 support for X710-T2L/T4L and XXV710 - Support RHEL8.6/9.0, SLES 15SP4 Note on Firmware Recovery Mode: When a device is in Firmware Recovery mode it will not pass traffic or allow any configuration; you can only attempt to recover the device's firmware. A device will enter Firmware Recovery mode if it detects a problem that requires the firmware to be reprogrammed. Resolving Firmware Recovery Mode Issues: If your device is in Firmware Recovery mode you can restore it to factory defaults using the latest NVM Update Package. Download the latest NVM Update Package from your vendor's support website and follow the instructions in it. *** NOTES: - Before initiating device recovery, the integrity of the host operating system, device drivers and firmware utilities must be verified and reinstalled if necessary. Fully functional operating system, device drivers and tools are required for device recovery. - AC power cycle your system even if the instructions do not indicate that an AC power cycle is required. A power cycle is required to enable the device to restore and reload critical device settings to enable recovery. To perform an AC power cycle, do the following: a. Shut down the system if it is powered up. b. Unplug all AC power cords from the system. c. Leave the AC power cords unplugged for 15 seconds to allow the system power supply to discharge completely. d. Plug in AC power cords to the system. - Firmware Recovery Mode Errors and Messages: When a device is in Firmware Recovery mode, the device drivers and preboot software and utilities may log or display messages such as the following: a. Firmware recovery mode detected. Limiting functionality. Refer to the Intel(R) Ethernet Adapters and Devices User Guide for details on firmware recovery mode. b. Firmware recovery mode detected. Initialization failed. c. Firmware recovery mode detected. Limiting functionality. d. PXE-E0C: Firmware recovery mode detected. Initialization failed. 2.0 Web Sites and Support Phone Number ______________________________________ o You can download new and updated files for Lenovo products from the Lenovo Web site: http://datacentersupport.lenovo.com/ o With the original purchase of an Lenovo hardware product, you have access to extensive support coverage. During the Lenovo hardware product warranty period, you may call the Lenovo HelpCenter for hardware product assistance covered under the terms of the Lenovo hardware warranty. 3.0 Trademarks and Notices __________________________ Lenovo is a registered trademark of Lenovo Corporation in the United States and other countries. Intel is a registered trademark of Intel Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. 4.0 Disclaimer ______________ THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. Lenovo DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, Lenovo GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with Lenovo Corporation.
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |
Release: 29.1 08/01/2024 ============================ New OS Support: - Support RHEL8.9/9.3 E810 ------------- New features: - Get SFF Info NC-SI OEM Command - Disable FW LLDP agent in and allow LLDP frames to be sent and received in the VF. - Supports Log of MNG packets for debugging purposes. - Supports PLDM Type 4s for FRU data. - The E810-CQDA2T adapter now supports 2x2x25 Gbps configuration. - Supports reduced PTP jitter by improved timestamp accuracy and Port timer compensation. - E810-XXVDA4T and E810-CQDA2T now support DPLL updates. - Supports shorter DPLL lock time - Force FW LOG to uART even if PF Driver disables - Option to disable PLDM FRU backup data response when NVM FRU manufacturing data is not available Bug fixes: - IPS: 00788617 - [PA_SI Agile 23-1_USI_SDV_Pass 1_HW_SE450] Qtester shows "VPD FW check failed (Error) Description: 1. Power on system and boot into WS2022. 2. Setup Qtester to run 72hrs AC cycle test. after AC power on, the BMC software calls PLDM_GetFirmwareParameters and it sometimes (may be once after 300 AC power cycles) returns Completion Code = 0x01(PLDM Base: Error). Fix: Firmware now returns PLDM_ERROR_NOT_READY Completion Code instead of generic 0x01(PLDM Base: Error) when firmware is not fully ready after platform reboot. - When plugging DAC cables into two ports at the same time on Clifton Channel, it is possible for one port to be unable to establish link. - To have the metrics data shown on the respective port, map the port to MAC address before accessing counter registers. - Resolved an issue where 0x5089 was returned for command get_sff_temperature when only port1 had optics of E810. - PLDM T2 NumericSensors didn't send async event when any threshold was crossed. - NCSI1.2 command Get Transceiver Temperature(0x4A) returned incorrect temperatures due to wrong endianness. - Module temp thresholds check running too early causes 0 return, which is taken as valid and shuts down port. - GetSensorReading command returns error code 0x1 in case when plug temperature is higher than 78C (0x4E). - E810 doesn't support non-contiguous TCs within the LLDP configuration. It may result in a hang situation if receiving such LLDP packets during power-on stage. A timeout was added to the firmware polling loop to trigger a core reset which clears the hang and allows the device to continue functioning. - E810 4.3 NVMs use a common map, which introduces a change (new entries) to an immediate TLV in PFA. FW fails to interpret the new entries in this specific TLV, which results in adding those new entries again and again upon every update from the former 4.3 image to 4.3 and above. Eventually, due to the lack of space in that TLV, any normal attempt to update will fail. - NetworkDeviceFunction.Ethernet.PermanentMACaddress should stay with factory setting if it has been programmed. Read relevant section from Factory Settings. - PLDM Type4 showing incorrect default Part Number - NIC disappeared after NVM signature corruption - Incorrect log entry format for timestamp value - Get Link Status command does not return External Device Power Class value - Previously, the PLDM Type 5 Command "Activate Firmware" could potentially cause a subsequent PLDM Type 2 event. - Resolved an issue where during an ActiveFirmware request coming from Update Agent (BMC) PLDM Type2, a PlatformEventMessage was generated by the Firmware Device (Network Adapter). As a result, the response did not happen, and Update Agent (BMC) treated it as Update Failed. - Fixed an issue where the UEFI HII interface could not save the setting of virtualization mode. - Previously, in PLDM Platform Monitoring and Control, the sensor_data_size field of SFP thermal sensor PDR was containing wrong value: unsigned instead of signed char/byte. - Previously, during ActiveFirmware request coming from Update Agent (BMC) PLDM Type2 PlatformEventMessage was generated by our Firmware Device (Network Adapter). As a result, response did not happen and Update Agent (BMC) treated it as Update Failed. - Firmware now acquires semaphore before "Load Factory Settings to PFA" and releases it immediately after. - Previously, when BMC subscribed to PLDM events, the NIC issued two equivalent redfish events for the different origins (Network Adapter and Port) caused by the same trigger (link state change for given port). This issue caused unnecessary redfish event flood. The resolution was to change firmware design in order to avoid sending multiple redfish events for the same trigger. - Previously, in Network Controller Sideband Interface after EnableChannel command invoked, the OEM command IANA=0x02A2 GetLldp occasionally returned LLDP TLVs with missing mandatory values for chassis_id and port_id. - Set packageID SDP to correct values for E810-CQDA1. - Now the patched property of NetworkDeviceFunction.Ethernet.MACAddress is persistent during reboot. Users can restore to PermanentMACAddress with ResetSettingsToDefaults. FVL/SGVL -------- New features: - Enable E700 X722 Tx signal to "always on". - Enable E700 to store events details on the NVM in Recovery Mode.When entering the Recovery Mode, X710 will store the details of the event in the NVM. Bug fixes: - Resolved an issue where POST to the NetworkAdapter.ResetSettingsToDefault looked successful from postman, but after reboot the adapter's Port 1 LLDP setting did not reset to default. - Previously, there were cases of Fortville disappearing from the PCIe bus during reboot stress testing reported on Icelake-based platforms. These platforms performed a PCIe Hot Reset before asserting PERST# as part of the warm reboot cycle. PERST# is asserted at approximately the end of the Hot Reset, but due mostly to the Fortville LCB implementation, there was a variation in the relative timing of about 65 us, so many edge cases could occur. - Previously, after configuring "ifconfig ethX down" command on Marvell devices series 88E1512/88E1514, the peer side (loopback configuration) was still reporting link up. - Fixed an issue. Unexpected EMP Reset occurred in a rarely BMC request combination in a very low probability, which may cause: 'tx_timeout' or 'ARQ: Unknown event 0x0000 ignored' or 'bond down' if bonding is configured. - IPS: 00879846 - Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Adapter link speed and status incorrect Description: Link event is reported only once at when the machine is powered on, after that no link event will be generated any more even after the network cable is inserted and removed, this is incorrect, link event should be reported when we plugin or remove the AOC cable. Fix: Firmware reported link speed value based on advertised capability value using DNL declaration, changes to read link speed from MAC - IPS: 00852370 - IEPD Hot Issue: SR645v3 X710 T2L PCIe bandwidth degraded Description: X710 PCIe may enter x1 on the AMD Genoa platform in reboot and AC process. Customer updated system firmware XCC: KAX318V >> KAX322V UEFI: KAE112O >> KAE116K Following event occurs intermittently, but high fail rate PCIe Link Width has degraded from x8 to x1 in physical slot number 3. Slot 3 is Intel X710-T2L 10GBASE-T 2-Port PCIe Ethernet Adapter, customer had tried new NIC FW, replace NIC but no help. this system no re-timer. Fix: The firmware changes to enter the PCIE detection phase when PERST becomes de-asserted Release: 28.2 08/01/2023 ======================== New OS Support: - Support RHEL8.8/9.2, SLES 15.5 E810 ------------- New features: - Support NC-SI 1.2 thermal monitoring commands. Bug fixes: - IPS: 00833367 - E810-DA2 10/25GbE SFP28 2-Port OCP Ethernet Adapter cannot enable SRIOV in UEFI Description: SRIOV can not be enabled in UEFI Fix: Added logic to support on for all PFs - Resolved an issue were an incorrectly interpreted BDF during MCTP Endpoint discovery led to sending PLDM events to a non-existing device. - Resolved an issue where the id field of Event BEJ was changed from the originating resource Id as the resource number to a deferred binding resource Id. - A "Cannot initialize port" failure occurs when running nvmupdate 1.39.32.6 in SLES15SP3, because the tool doesn't support ioctl. - A SyncE-related transaction between driver and device may cause a PHY loading failure, during NVM upgrade. Subsequently, PHY errors are reported to UEFI driver during reboot, resulting in a BIOS hang. - Resolved an issue where E810-XXV-4T didn't expose one of the On Chip thermal sensors via PLDM. The sensor was not visible via BMC. - Resolved an issue where CVL4.1 and CVL4.2 had a problem with Recovery Clock configuration on port 4, in the case of fully reversed PF<>MAC mapping. Other configurations were not impacted. - Resolved an issue where the NC-SI "Reset Channel" (0x05) command was not reverting the port link state change made by for Real Time Comprehensive Embedded Management "Network Port Control' (0x34) command. - Resolved an issue where, during communication via PLDM Type 6, FW did not move the operation to the failed state and did not return INVALID_DATA. Instead, it returned UNSUPPORTED in the case of an invalid payload. - Reverted an incorrectly added strict handling of the payload-less action. - Resolved an issue where the Network Device and Port Metrics are disabled due to an BMC issue and missing support on BMC side. - Resolved an issue where in order to change the Forward Error Correction setting in the UEFI HII the user needs to change the Media detection setting, save the changes, and then change the FEC setting. - Previously, promiscuous mode did not see all packets; it only saw those packets arriving over the wire (that is, not sent from the same physical function (PF) but a different virtual function (VF). - Resolved an issue where during the second time of a POST operation, NetworkAdapter.ResetSettingsToDefault failed with the BMC reporting "Internal Server Error." - Resolved an issue when both RMII-based transport (RBT) and Management Component Transport Protocol (MCTP) were enabled, and PT was enabled on RBT, then OEM command 0x26 (config LLDP) was being rejected from NC-SI over MCTP with reason code 0x5081. - Corrected an issue where updating an NVM image of E810 could result in a "PHY NVM is not supported in devlink" warning message. - Previously, E8102CQDA2 adapter showed Linkcap width as x16. FVL/SGVL -------- New features: - Get Link Status AQC response when SFP module is not initialized. Description: If the Get Link Status AQC is sent when the SFP module is not initialized yet, the link can be lost. When the SFP module is not initialized yet, FW will try again in a reasonable timeout. Bug fixes: - IPS: 00819239 - [Kahauale_BBFV_HCT]X710-T4L NIC adapter can't saved the "Active Physical Functions" option on uEFI menu. IPS: 00831264/00844425 - XXV710-DA2 PCIe Adapter NIC port didn't disable after changed the "Active physical functions" Description: Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Adapter NIC port didn't disable after changed the "Active Physical" setting on uEFI menu. Fix: Reset the length of the PCIe Alt Autoload section during image downgrade to a version earlier than FVL9.2 - IPS: 00840914 - [PA_IO Agile-Sprint202310_BDC_Storage_flex]SRIOV enable/disable both can do SRIOV features Description: OS can still create SRIOV VFs when the adapter HII already disables SRIOV in the BIOS IPS: 00841528 - [PA_IO Agile-Sprint202310_BDC_Storage_SD530] Intel X722 LOM test SR-IOV function cannot enable VF under ESXi8.0u2 OS Description: Open to enter ESXi Host Client-Manage-Hardware-PCI Devices-Select Port "Intel X722 10GB SFP+" Configure SR-IOV 2.UEFI has set SR-IOV function 3.ESXi8.0u2 Unable to enable VF redhat 9.2 can work well. Fix: Correctly set SR-IOV Control Capable bit for Lenovo images, - IPS: 00839473 - [PA_IO Agile-Sprint202209_BDC_oceancat_Sprint202310]X722 lom WOL fail in SD650. Description: WOL function UEIF page show gray, OS can not enable WOL function Fix: Enable force link down requests and map channel number in a descending order. Enable AltRAM implementation then reset corrupted memory block and recalculate MSI_X VF vectors. - IPS: 00831248 - XXV710 VPD info question Description: lspci -s BUS:Device.Function -vvv command to check VPD info, but it can't show out the VPD info Fix: Enable VPD bit in NVM image - IPS: 00769725 - [Hakuba] Abnormal cable plug (unplug) event on port 2 and 3 with Intel X710-T4L Description: Port2 and port3 of X710-T4L PCIE cannot display event in audit log and link status/speed in inventory when plug/unplug the cable. Fix: There are missing MCTP link status changes as mixed PF no. with port no. in the MCTP Link Status change handler, and overflowing PLDM queue with RDE events that were classified as Big Event. Map Port No. to the corresponding PF and continue, add additional condition to disable unplanned eventReceiver physical address change. Disable RDE events in the presence of asynchronous MCTP implementation without polling for Big Events Note: it may still occur in loopback mode. - IPS: 00725539 - Link down on x722 4x10Gb SFP+ PHY card with 27.3 code level (800039xx) Description: After upgrading the FW, all ports are down. Fix: Force OCP PnP Autodetection flow after NVM update. - Resolved an issue where a rare PCI speed degradation with Gen3 to Gen2 was seen during extensive link tests after a reset is caused by a core reset on an ICX-D platform. - Resolved an issue where during a write, with http PATCH method triggered, the LLDP Disable Valid bit was ignored, which resulted in a skip of write in all scenarios instead of just for the same LLLDP Enabled value. - Resolved an issue where if BMC bonding was disabled, NCSI mode was set to a Manual Switch Mode (depending on the platform), and BMC share port has changed before doing a power cycle, recovery mode would occur. Other prerequisites include disabled WOL, disabled LLDP, enabled PXE no drop, and disabled auto power-on after power loss (in BIOS). - Fixed an issue where the processing port id was always the same as the mac address - Previously, the addition of PCIe re-timers added to the total channel latency causing replay timer timeout correctable errors. - Resolved an issue where PLDM type MCTP packets were not accepted due to missing configuration for PCIe VDM I350/340/210 ------------ New features: - IPS: 00699338 - Name of I350 interlock in XCC is inconsistent with V1 Description: Card Name field shall be taken from V1 VPD field instead of "large resource string". This change applies to 1G Lenovo devices with enabled AIM support and existing V1 VPD field. Release: 28.0 02/16/2023 ======================== E810 ------------- New features: - Support RHEL8.7/9.1, ESXi 8.0 - OROM update support in Recovery mode Description: With this implementation, the NVM host update flow in recovery mode should be the same as in the operational mode. - Defines the IID (Instance IDs) field in the NC-SI packet's header, which is used to match responses to requests and to differentiate between new and retried commands. Description: According to the spec, If the IID of the current command is the same as the previous command's IID, the command is a "Retried Command" and the FW shall return the response of previous command (should be done without re-executing the command). When the IID is different than from the previous command, the command is executed. The NC-SI spec is unclear on if the incoming commands IID is compared to the IID of the previous command received on the same channel, package or device. This feature defines a transfer to maintaining a single buffer for the last NC-SI command received on the device per transmitting interface. - Add FC-FEC(CL74) support with optical transceiver 25G-SR - NVMUpdate - only access devices from config file Description: The affected component shall only access devices (read/write flash or registers) listed in config file that match the following criteria: * if device in config file contains: DEVICE and VENDOR all devices with specified device ID and vendor ID will be accessed; * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR all devices with specified 4partID will be accessed, * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR, REVISION all devices with specified 4partID and specific revision will be accessed. Device not listed in config file (do not match the criteria above) shall be marked as "Update not available' in interactive mode. - NVMUpdate - OROM update in recovery Description: If the device is in recovery mode and has the capability of supporting for OROM update in recovery mode. it can be updated OROM either from NVM image or from separate file (FLB). - RoCEv2 LAG - FEC auto-detect for CVL LR/SR mode Description: Only valid FEC modes will be attempted based on the media and PHY type. - Enable hardware arbitration - IPS: 00675913 - FEC Configuration through UEFI HII for 25G CVL adapters Bug fixes: - IPS: 00796141 - E810 fails to link with 10/25Gb SFP28 connect to adapter and 10Gb SFP+ connected Description: Connect Lenovo 10/25Gb SFP28 to E810, Lenovo 10Gb SFP+ to switch (CISCO 9K) Link fails to come up. Fix: Change the preserved "LinkDefaultOverrides" fields in the NVM image so that the settings in the NVM images make the firmware to try all the FEC modes during the link training. - IPS: 00736066 - [PA_IO Agile-Sprint202209_BDC_Storage_SR655] E810-DA2 OCP ShareNIC cannot obtain DHCP IP under SR655 Description: BMC failed getting an IP address on the sharenic port of E810-xxvDA2 OCP via DHCP Fix: Use proper packageID SDP settings for SDP0 and SDP1 - IPS: 00735574 - [PA_QUR 22C_BDC_SDV_FW_AMD1P_UEFI][RMK-5883]E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP Destination: E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP. Fix: In implementation, use different variables to identify VSI in different context. - Both ports are loosing link randomly after dcb-map change Destination: The E810 adapter might experience an adapter-wide reset (all ports) when the DCBx willing configuration change (in firmware managed mode) propagated from the switch removes a TC that was RDMA enabled. This typically occurs when removing a TC associated with UP0 because it's the default UP that RDMA based it's configuration on. The reset results in a temporary loss in connectivity as the adapter re-initializes. Fix: FW changes along with changes in SW to allow for RDMA to disable QueueSets before suspending the removed TCs from the scheduler tree. FVL/SGVL -------- New features: - Defines the IID (Instance IDs) field in the NC-SI packet's header, which is used to match responses to requests and to differentiate between new and retried commands. Description: According to the spec, If the IID of the current command is the same as the previous command's IID, the command is a "Retried Command" and the FW shall return the response of previous command (should be done without re-executing the command). When the IID is different than from the previous command, the command is executed. The NC-SI spec is unclear on if the incoming commands IID is compared to the IID of the previous command received on the same channel, package or device. This feature defines a transfer to maintaining a single buffer for the last NC-SI command received on the device per transmitting interface. Bug fixes: - XXV710DA2 adapter intermittently lose link when doing DC power cycle test Description: XXV710DA2 adapter intermittently lose link when doing DC power cycle test, this can be reproduced in about 200 DC cycle. Fix: When the FW starts to run, the gearbox has to be initialized and configuration needs to be downloaded from the NVM and applied. If one of the operation fails the FW will try again (several times). In this case the configuration failed with the error which was not covered. Error handling extended in the code to cover all cases - Package Port Control command with Port Control equals 0x1 works like reset if link is already up Description: In Campbell Pond, send Package Port Control Command to disable the port, send command to enable it, then send command to enable it again. The port is down instead of up. Fix: Added link status check in package command. - Link Status Change AEN event is not send after link down Description: Sending AEN Enable command with Link Status Change equals true, then sending Port Control Command with Port Control field equals 0x0 - disable. There is no event after link down. Fix: Changed event rejection condition to response. - After running reboot 123 times with qtest, slot4 (X710-T2L) shows an error Description: Used qtest ro run reboot 123 times, xcc web appears: PCIe Correctable Error Threshold limit has been exceeded at Segment 0x0000 Bus 0xA8 Device 0x00 Function 0x01. Fix: Adjust the replay timer timeout value for different scenarios.
Lenovo Data Center Group Linux OS Support Home Page |
linux.lenovo.com |
© 2018-2024 Lenovo. All rights reserved |