Lenovo YUM Repository
| Targeted Server Family (Machine Type): ThinkSystem ST50 V2 (7D8J, 7D8K, 7D8L) |
| Targeted Operating System: SLES15SP6 |
| YUM Repository Build Date: 2025_03_24 |
|
Lenovo Hosted Base URL: https://linux.lenovo.com/yum/2025_03/ST50V2_7D8J_7D8K_7D8L/SLES15SP6 Lenovo Authenticity Security Key Download: https://download.lenovo.com/servers_pdf/LenovoDCG_publickey4096b2022-2025 Key Fingerprint: How to use Lenovo Linux YUM Device Driver Bundles |
| Supported Device Listing (Links to supported firmware/driver version information) |
| Device Supported Code Levels |
| All Supported NVMe Drives | Part Number: NA_NVMe Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.52.04-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.2.0-24.10.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported Solid State Drives | Part Number: NA_SSD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.52.04-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.2.0-24.10.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SAS Drives | Part Number: NA_SASHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.52.04-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SATA Drives | Part Number: NA_SATAHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.52.04-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| Intel X550-T2 Dual Port 10GBase-T Adapter |
Device Product Guide |
Part Number: 00MM860 Feature Code: ATPX |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x0022 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.52-6.50-1.3684.0-4 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-i40e enablement code |
intel-i40e-2.26.6-150600.1.1.x86_64.rpm | 2.26.6 | ||||
| intel-i40e-kmp-default enablement code |
intel-i40e-kmp-default-2.26.6_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 2.26.6_k6.4.0_150600.21 | ||||
| intel-ice enablement code |
intel-ice-1.15.4-150600.2.1.x86_64.rpm | 1.15.4 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-1.15.4_k6.4.0_150600.21-150600.2.1.x86_64.rpm | 1.15.4_k6.4.0_150600.21 | ||||
| intel-igb enablement code |
intel-igb-5.17.4-150600.1.1.x86_64.rpm | 5.17.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.17.4_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.17.4_k6.4.0_150600.21 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-1.15.12_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 1.15.12_k6.4.0_150600.21 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-5.21.5-150600.1.1.x86_64.rpm | 5.21.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-5.21.5_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.21.5_k6.4.0_150600.21 | ||||
| ThinkSystem Intel I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00534 Feature Code: AUZY |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x00A2 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.52-6.50-1.3684.0-4 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-i40e enablement code |
intel-i40e-2.26.6-150600.1.1.x86_64.rpm | 2.26.6 | ||||
| intel-i40e-kmp-default enablement code |
intel-i40e-kmp-default-2.26.6_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 2.26.6_k6.4.0_150600.21 | ||||
| intel-ice enablement code |
intel-ice-1.15.4-150600.2.1.x86_64.rpm | 1.15.4 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-1.15.4_k6.4.0_150600.21-150600.2.1.x86_64.rpm | 1.15.4_k6.4.0_150600.21 | ||||
| intel-igb enablement code |
intel-igb-5.17.4-150600.1.1.x86_64.rpm | 5.17.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.17.4_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.17.4_k6.4.0_150600.21 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-1.15.12_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 1.15.12_k6.4.0_150600.21 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-5.21.5-150600.1.1.x86_64.rpm | 5.21.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-5.21.5_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.21.5_k6.4.0_150600.21 | ||||
| ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | Part Number: 7ZT7A00535 Feature Code: AUZW |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x00A1 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.52-6.50-1.3684.0-4 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-i40e enablement code |
intel-i40e-2.26.6-150600.1.1.x86_64.rpm | 2.26.6 | ||||
| intel-i40e-kmp-default enablement code |
intel-i40e-kmp-default-2.26.6_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 2.26.6_k6.4.0_150600.21 | ||||
| intel-ice enablement code |
intel-ice-1.15.4-150600.2.1.x86_64.rpm | 1.15.4 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-1.15.4_k6.4.0_150600.21-150600.2.1.x86_64.rpm | 1.15.4_k6.4.0_150600.21 | ||||
| intel-igb enablement code |
intel-igb-5.17.4-150600.1.1.x86_64.rpm | 5.17.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.17.4_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.17.4_k6.4.0_150600.21 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-1.15.12_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 1.15.12_k6.4.0_150600.21 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-5.21.5-150600.1.1.x86_64.rpm | 5.21.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-5.21.5_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.21.5_k6.4.0_150600.21 | ||||
| ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port PCIe Ethernet Adapter (GP servers) | Part Number: 4XC7A08295 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4003 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da2.pcie-4.60-1.3684.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-i40e enablement code |
intel-i40e-2.26.6-150600.1.1.x86_64.rpm | 2.26.6 | ||||
| intel-i40e-kmp-default enablement code |
intel-i40e-kmp-default-2.26.6_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 2.26.6_k6.4.0_150600.21 | ||||
| intel-ice enablement code |
intel-ice-1.15.4-150600.2.1.x86_64.rpm | 1.15.4 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-1.15.4_k6.4.0_150600.21-150600.2.1.x86_64.rpm | 1.15.4_k6.4.0_150600.21 | ||||
| intel-igb enablement code |
intel-igb-5.17.4-150600.1.1.x86_64.rpm | 5.17.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.17.4_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.17.4_k6.4.0_150600.21 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-1.15.12_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 1.15.12_k6.4.0_150600.21 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-5.21.5-150600.1.1.x86_64.rpm | 5.21.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-5.21.5_k6.4.0_150600.21-150600.1.1.x86_64.rpm | 5.21.5_k6.4.0_150600.21 | ||||
| ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00482 Feature Code: AUZX |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x402D |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme (NX1) Networking Adapter/Device Linux Firmware | nx1-230.0.3.1-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00484 Feature Code: AUZV |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x402D |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme (NX1) Networking Adapter/Device Linux Firmware | nx1-230.0.3.1-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00496 Feature Code: AUKP |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4160 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-230.1.116.0-6 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem 4350-8i SAS/SATA 12Gb HBA | Part Number: 4Y37A72480 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0220 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Adapter Linux Firmware | smartpqi.350-6.82-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem RAID 5350-8i PCIe 12Gb Adapter | Part Number: 4Y37A84028 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0522 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Adapter Linux Firmware | smartpqi.350-6.82-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
Lenovo Data Center Group Linux OS Support Home Page |
| linux.lenovo.com |
© 2018-2025 Lenovo. All rights reserved |