Lenovo YUM Repository
| Targeted Server Family (Machine Type): ThinkSystem SE350 (7Z46, 7D1X, 7D27) |
| Targeted Operating System: SLES15SP7 |
| YUM Repository Build Date: 2026_09_15 |
|
Lenovo Hosted Base URL: https://linux.lenovo.com/yum/2026_09/SE350_7Z46_7D1X_7D27/SLES15SP7 Lenovo Authenticity Security Key Download: https://download.lenovo.com/servers_pdf/LenovoDCG_publickey4096b2025 Key Fingerprint: How to use Lenovo Linux YUM Device Driver Bundles |
| Temporary limitation - Intel i40e driver not included in this repository |
|
The Intel i40e Ethernet driver RPMs (intel-i40e and intel-i40e-kmp-default) have been left out of this SLES 15 repository on purpose. In the current Intel NIC device driver package, intel-i40e-kmp-default requires intel-irdma-kmp = 2.0.26, while the package ships intel-irdma-kmp 2.0.33. The dependency can never be satisfied, so zypper and rpm fail to install the driver. All other drivers from the same package (ice, igb, ixgbe, irdma) are unaffected and remain available in this repository.
To install the i40e driver, download the Lenovo device driver package for your machine type and run the install.sh script included in it. That script installs the RPMs with --nodeps and completes successfully. A corrected driver package is planned for I/O Code Agile Release 2703, after which the i40e RPMs will return to this repository automatically. Tracking: TDCSW-221 / IONG-15184 |
| Supported Device Listing (Links to supported firmware/driver version information) |
| Device Supported Code Levels |
| All Supported NVMe Drives | Part Number: NA_NVMe Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.4.1-26.06.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported Solid State Drives | Part Number: NA_SSD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.4.1-26.06.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SAS Drives | Part Number: NA_SASHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SATA Drives | Part Number: NA_SATAHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem SE350 4xRJ45 10GBASE-T LOM Package 10GBASE-T Wired Network Module (10GBase-T interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 10/100/1GbE RJ45 2-Port Intel i350 SFP+ Wired Network Module (10G SFP+ Interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 1GbE SFP 2-Port Switch, Wireless Capable Wireless Network Module w/ LTE support (10G SFP+ interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 1GbE SFP 2-Port Switch, Wireless Capable Wireless Network Module w/ LTE support (NXP interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 1GbE SFP 2-Port Switch, Wireless Capable Wireless Network Module (10G SFP+ interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 1GbE SFP 2-Port Switch, Wireless Capable Wireless Network Module (NXP interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4025 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| System x3250 LOM | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4016 |
||||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port PCIe Ethernet Adapter (GP servers) |
Device Product Guide |
Part Number: 4XC7A08295 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4003 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da2.pcie-4.90-1.3897.0-0 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| ThinkSystem SE350 4xRJ45 10GBASE-T LOM Package 10GBASE-T Wired Network Module (GbE interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4016 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem SE350 10GbE SFP+ 2-Port, 10/100/1GbE RJ45 2-Port Intel i350 SFP+ Wired Network Module (GbE Interface) | Part Number: NA Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4016 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter (using Advanced RDMA functionality) | Part Number: 4XC7A08249 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0105 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter (using Basic RDMA functionality) | Part Number: 4XC7A08249 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0105 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit (Device 1) | Part Number: 4M17A37606 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0302 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Boot Device (M.2/U.2) Firmware | se350-2.3.22.1007-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit (Device 2) | Part Number: 4M17A37606 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0303 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Boot Device (M.2/U.2) Firmware | se350-2.3.22.1007-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem SE350 M.2 Mirroring Enablement Kit | Part Number: 4M17A60519 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0300 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Boot Device (M.2/U.2) Firmware | se350-2.3.22.1007-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00484 Feature Code: AUZV |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x402D |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme (NX1) Networking Adapter/Device Linux Firmware | nx1-237.0.4.1-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| broadcom-tg3-kmp-default enablement code |
broadcom-tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm | 3.139y_k6.4.0_150700.51 | ||||
| ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00496 Feature Code: AUKP |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4160 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-237.1.148.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| broadcom-bnxt_en-kmp-default enablement code |
broadcom-bnxt_en-kmp-default-1.10.3.237.1.137.0_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 1.10.3.237.1.137.0_k6.4.0_150700.51 | ||||
| libbnxt_re enablement code |
libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm | 237.1.137.0 | ||||
| SE350 Embedded Networking Module | Part Number: SBB7A15288 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Embedded Network Module Firmware | hyl430a-1.14 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
Lenovo Data Center Group Linux OS Support Home Page |
| linux.lenovo.com |
© 2018-2026 Lenovo. All rights reserved |