Lenovo YUM Repository
| Targeted Server Family (Machine Type): ThinkSystem SR670 V2 (7Z22, 7Z23) |
| Targeted Operating System: SLES15SP7 |
| YUM Repository Build Date: 2026_09_15 |
|
Lenovo Hosted Base URL: https://linux.lenovo.com/yum/2026_09/SR670V2_7Z22_7Z23/SLES15SP7 Lenovo Authenticity Security Key Download: https://download.lenovo.com/servers_pdf/LenovoDCG_publickey4096b2025 Key Fingerprint: How to use Lenovo Linux YUM Device Driver Bundles |
| Temporary limitation - Intel i40e driver not included in this repository |
|
The Intel i40e Ethernet driver RPMs (intel-i40e and intel-i40e-kmp-default) have been left out of this SLES 15 repository on purpose. In the current Intel NIC device driver package, intel-i40e-kmp-default requires intel-irdma-kmp = 2.0.26, while the package ships intel-irdma-kmp 2.0.33. The dependency can never be satisfied, so zypper and rpm fail to install the driver. All other drivers from the same package (ice, igb, ixgbe, irdma) are unaffected and remain available in this repository.
To install the i40e driver, download the Lenovo device driver package for your machine type and run the install.sh script included in it. That script installs the RPMs with --nodeps and completes successfully. A corrected driver package is planned for I/O Code Agile Release 2703, after which the i40e RPMs will return to this repository automatically. Tracking: TDCSW-221 / IONG-15184 |
| Supported Device Listing (Links to supported firmware/driver version information) |
| Device Supported Code Levels |
| All Supported NVMe Drives | Part Number: NA_NVMe Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.4.1-26.06.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported Solid State Drives | Part Number: NA_SSD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Utility | Utility Name | Version | ||||
| Lenovo Wear Gauge Storage Linux Utility | all.ss.wg-10.4.1-26.06.23-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SAS Drives | Part Number: NA_SASHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| All Supported SATA Drives | Part Number: NA_SATAHDD Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| Core System Device Install Drivers on all Servers |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Linux Firmware | all-1.58.02-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem 430-8i SAS/SATA 12Gb HBA |
Device Product Guide |
Part Number: 7Y37A01088 Feature Code: AUNL |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0200 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Host-Bus-Adapter (HBA) Linux Firmware | mpt3.5.430-24.05.00.00-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-mpt3sas-kmp-default enablement code |
lsi-mpt3sas-kmp-default-56.00.01.00_sles15sp7-1.x86_64.rpm | 56.00.01.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem 430-8e SAS/SATA 12Gb HBA |
Device Product Guide |
Part Number: 7Y37A01090 Feature Code: AUNR |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0202 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Host-Bus-Adapter (HBA) Linux Firmware | mpt3.5.430-24.05.00.00-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-mpt3sas-kmp-default enablement code |
lsi-mpt3sas-kmp-default-56.00.01.00_sles15sp7-1.x86_64.rpm | 56.00.01.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A08278 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x000F |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel X710-T2L 10GBASE-T 2-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A80266 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4009 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel X710-T4L 10GBASE-T 4-Port OCP Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A80268 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4012 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| Intel X550-T2 Dual Port 10GBase-T Adapter |
Device Product Guide |
Part Number: 00MM860 Feature Code: ATPX |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x0022 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| net.sd-9.55-6.50-1.3866.0-10 | ||||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00535 Feature Code: AUZW |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x00A1 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| net.sd-9.55-6.50-1.3866.0-10 | ||||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter | Part Number: 7ZT7A00537 Feature Code: AUKX |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x000A |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net-9.55-6.50-1.3866.0-10 | |||||
| net.sd-9.55-6.50-1.3866.0-10 | ||||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| Utility | Utility Name | Version | ||||
| Intel Networking Adapter/Device Utility | net-30.4-6 | |||||
| ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port OCP Ethernet Adapter (GP servers) |
Device Product Guide |
Part Number: 4XC7A08294 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4002 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da2.ocp-4.90-1.3897.0-0 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-port OCP Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A80269 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4013 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da4.ocp-4.90-1.3897.0-0 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-port PCIe Ethernet Adapter (GP servers) |
Device Product Guide |
Part Number: 4XC7A08295 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4003 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da2.pcie-4.90-1.3897.0-0 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A80267 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x8086 PCIe Sub Device ID: 0x4010 |
||||||
| Firmware | Firmware Name | Version | ||||
| Intel Networking Adapter/Device Linux Firmware | net.e800.da4.pcie-4.90-1.3897.0-0 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| intel-ice enablement code |
intel-ice-2.3.14-150700.1.1.x86_64.rpm | 2.3.14 | ||||
| intel-ice-kmp-default enablement code |
intel-ice-kmp-default-2.3.14_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.3.14_k6.4.0_150700.51 | ||||
| intel-igb enablement code |
intel-igb-5.19.4-150700.1.1.x86_64.rpm | 5.19.4 | ||||
| intel-igb-kmp-default enablement code |
intel-igb-kmp-default-5.19.4_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 5.19.4_k6.4.0_150700.51 | ||||
| intel-irdma-kmp-default enablement code |
intel-irdma-kmp-default-2.0.33_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 2.0.33_k6.4.0_150700.51 | ||||
| intel-ixgbe enablement code |
intel-ixgbe-6.2.5-150700.1.1.x86_64.rpm | 6.2.5 | ||||
| intel-ixgbe-kmp-default enablement code |
intel-ixgbe-kmp-default-6.2.5_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 6.2.5_k6.4.0_150700.51 | ||||
| ThinkSystem RAID 530-8i PCIe 12Gb Adapter |
Device Product Guide |
Part Number: 7Y37A01082 Feature Code: AUNG |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0500 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.530-51.23.0-5631-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter-Dep2506 | Part Number: 4Y37A78834 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0505 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.540-52.36.0-6554-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter |
Device Product Guide |
Part Number: 7Y37A01084 Feature Code: AUNJ |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0601 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.930-51.23.0-5631-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter |
Device Product Guide |
Part Number: 7Y37A01087 Feature Code: AUNQ |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0604 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.930-51.23.0-5631-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter | Part Number: 4Y37A09728 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x060A |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.940-52.36.0-6553-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter | Part Number: 4Y37A09729 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x060B |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.940-52.36.0-6553-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter | Part Number: 4Y37A78836 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x060F |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo RAID Adapter Linux Firmware | mr3.5.940-52.36.0-6553-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-megaraid_sas-kmp-default enablement code |
lsi-megaraid_sas-kmp-default-07.736.03.00_sles15sp7-1.x86_64.rpm | 07.736.03.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority RAID Adapter Linux Utility | mr3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI RAID Adapter Linux Utility | mr3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem SR670 V2 Switched 4x x16 PCIe Gen4 DW/SW GPU Dual | Part Number: 4XC7A69407 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x7819 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo PCIe Switch Firmware | yprc.a-08b-02.04.05.02-0 | |||||
| Lenovo PCIe Switch Firmware | yprc.b-08b-02.04.05.02-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA | Part Number: 4Y37A78601 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0207 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Host-Bus-Adapter (HBA) Linux Firmware | mpt3.5.440-37.125.09.00-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-mpt3sas-kmp-default enablement code |
lsi-mpt3sas-kmp-default-56.00.01.00_sles15sp7-1.x86_64.rpm | 56.00.01.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA | Part Number: 4Y37A78602 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0208 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Host-Bus-Adapter (HBA) Linux Firmware | mpt3.5.440-37.125.09.00-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-mpt3sas-kmp-default enablement code |
lsi-mpt3sas-kmp-default-56.00.01.00_sles15sp7-1.x86_64.rpm | 56.00.01.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA | Part Number: 4Y37A78837 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0209 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Host-Bus-Adapter (HBA) Linux Firmware | mpt3.5.440-37.125.09.00-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| lsi-mpt3sas-kmp-default enablement code |
lsi-mpt3sas-kmp-default-56.00.01.00_sles15sp7-1.x86_64.rpm | 56.00.01.00_k6.4.0_150700.51 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.lsa-008.016.008.000-0 | |||||
| Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility | mpt3.storcli-007.3603.0000.0000-2 | |||||
| ThinkSystem M.2 NVMe 2-Bay RAID Enablement Kit (OOB) | Part Number: 4Y37A09750 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0306 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Boot Device (M.2/U.2) Firmware | nvme.m2-1.0.20.1054-6 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit (OOB) | Part Number: 4Y37A09739 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0304 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Boot Device (M.2/U.2) Firmware | sata.v2-2.3.20.1011-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter (using Basic RDMA functionality)) |
Device Product Guide |
Part Number: 4C57A14177 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0015 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter (using Advanced RDMA functionality) |
Device Product Guide |
Part Number: 4C57A14178 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0035 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter (using Basic RDMA functionality) |
Device Product Guide |
Part Number: 4C57A14178 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0035 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter (using Advanced RDMA functionality) |
Device Product Guide |
Part Number: 4C57A15326 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0033 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter (using Basic RDMA functionality) |
Device Product Guide |
Part Number: 4C57A15326 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0033 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe 4 Ethernet Adapter (using Advanced RDMA functionality) |
Device Product Guide |
Part Number: 4XC7A08248 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0027 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe 4 Ethernet Adapter (using Basic RDMA functionality) |
Device Product Guide |
Part Number: 4XC7A08248 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0027 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter (using Advanced RDMA functionality) |
Device Product Guide |
Part Number: 4XC7A62580 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0013 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter (using Basic RDMA functionality) | Part Number: 4XC7A62580 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0013 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port OCP Ethernet Adapter (using Basic RDMA functionality) |
Device Product Guide |
Part Number: 4XC7A62582 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0014 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port OCP Ethernet Adapter (using Advanced RDMA functionality) | Part Number: 4XC7A62582 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0014 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem NVIDIA ConnectX-7 NDR400 OSFP 1-port PCIe Gen5 Adapter (Adv) |
Device Product Guide |
Part Number: 4XC7A80289 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0046 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem NVIDIA ConnectX-7 NDR400 OSFP 1-port PCIe Gen5 Adapter (Basic) |
Device Product Guide |
Part Number: 4XC7A80289 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0046 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Nvidia ConnectX-7 NDR200/HDR QSFP112 2-port PCIe Gen5 x16 IB/EN Adapter (Adv) |
Device Product Guide |
Part Number: 4XC7A81883 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0063 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Nvidia ConnectX-7 NDR200/HDR QSFP112 2-port PCIe Gen5 x16 IB/EN Adapter (Basic) |
Device Product Guide |
Part Number: 4XC7A81883 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0063 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem NVIDIA ConnectX-6 DX 200GbE QSFP56 1-port PCIe Ethernet Adapter (Advanced) | Part Number: 4XC7A83773 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0144 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem NVIDIA ConnectX-6 DX 200GbE QSFP56 1-port PCIe Ethernet Adapter (Basic) | Part Number: 4XC7A83773 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x15B3 PCIe Sub Device ID: 0x0144 |
||||||
| Firmware | Firmware Name | Version | ||||
| Nvidia-Mellanox ConnectX Networking Adapter/Device Linux Firmware | cx-doca-3.1.0-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| InBox Driver provided by Linux Distro install supported | ||||||
| ThinkSystem Broadcom 5719 1GbE RJ45 4-port OCP Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A08235 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4104 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme (NX1) Networking Adapter/Device Linux Firmware | nx1-237.0.4.1-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| broadcom-tg3-kmp-default enablement code |
broadcom-tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm | 3.139y_k6.4.0_150700.51 | ||||
| ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 7ZT7A00484 Feature Code: AUZV |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x402D |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme (NX1) Networking Adapter/Device Linux Firmware | nx1-237.0.4.1-2 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| broadcom-tg3-kmp-default enablement code |
broadcom-tg3-kmp-default-3.139y_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm | 3.139y_k6.4.0_150700.51 | ||||
| ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A08237 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4140 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-237.1.148.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| broadcom-bnxt_en-kmp-default enablement code |
broadcom-bnxt_en-kmp-default-1.10.3.237.1.137.0_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 1.10.3.237.1.137.0_k6.4.0_150700.51 | ||||
| libbnxt_re enablement code |
libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm | 237.1.137.0 | ||||
| ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter |
Device Product Guide |
Part Number: 4XC7A08238 Feature Code: na |
||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4105 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-237.1.148.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| broadcom-bnxt_en-kmp-default enablement code |
broadcom-bnxt_en-kmp-default-1.10.3.237.1.137.0_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 1.10.3.237.1.137.0_k6.4.0_150700.51 | ||||
| libbnxt_re enablement code |
libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm | 237.1.137.0 | ||||
| ThinkSystem Broadcom 57508 2x100/1x200GbE QSFP56 PCIe 4 Ethernet Adapter | Part Number: 4XC7A08297 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x404C |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-237.1.148.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| broadcom-bnxt_en-kmp-default enablement code |
broadcom-bnxt_en-kmp-default-1.10.3.237.1.137.0_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 1.10.3.237.1.137.0_k6.4.0_150700.51 | ||||
| libbnxt_re enablement code |
libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm | 237.1.137.0 | ||||
| ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port PCIe Ethernet Adapter | Part Number: 4XC7A80566 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x17AA PCIe Sub Device ID: 0x4107 |
||||||
| Firmware | Firmware Name | Version | ||||
| Broadcom NetXtreme E (NXE) Networking Adapter/Device Linux Firmware | nxe-237.1.148.0-2 | |||||
| Drivers | Driver Name | Discreate Package Download | Version | |||
| broadcom-bnxt_en-kmp-default enablement code |
broadcom-bnxt_en-kmp-default-1.10.3.237.1.137.0_k6.4.0_150700.51-150700.1.1.x86_64.rpm | 1.10.3.237.1.137.0_k6.4.0_150700.51 | ||||
| libbnxt_re enablement code |
libbnxt_re-237.1.137.0-sles15sp7.x86_64.rpm | 237.1.137.0 | ||||
| ThinkSystem 4350-8i SAS/SATA 12Gb HBA | Part Number: 4Y37A72480 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0220 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Adapter Linux Firmware | smartpqi.350-7.83-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| smartpqi-kmp-default enablement code |
smartpqi-kmp-default-2.1.36-026.sles15sp7.x86_64.rpm | 2.1.36 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo ARCCONF Storage Adapter Linux Utility | smartpqi.arcconf-5.03.00.27960-0 | |||||
| Lenovo maxView (storman) Storage Adapter Linux Utility | smartpqi.storman-5.03.00.27959-0 | |||||
| ThinkSystem RAID 5350-8i PCIe 12Gb Adapter | Part Number: 4Y37A72482 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0520 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Adapter Linux Firmware | smartpqi.350-7.83-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| smartpqi-kmp-default enablement code |
smartpqi-kmp-default-2.1.36-026.sles15sp7.x86_64.rpm | 2.1.36 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo ARCCONF Storage Adapter Linux Utility | smartpqi.arcconf-5.03.00.27960-0 | |||||
| Lenovo maxView (storman) Storage Adapter Linux Utility | smartpqi.storman-5.03.00.27959-0 | |||||
| ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter | Part Number: 4Y37A72483 Feature Code: na |
|||||
|---|---|---|---|---|---|---|
| PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0620 |
||||||
| Firmware | Firmware Name | Version | ||||
| Lenovo Storage Adapter Linux Firmware | smartpqi.350-7.83-0 | |||||
| Driver | Driver Name | Discreate Package Download | Version | |||
| smartpqi-kmp-default enablement code |
smartpqi-kmp-default-2.1.36-026.sles15sp7.x86_64.rpm | 2.1.36 | ||||
| Utilities | Utility Name | Version | ||||
| Lenovo ARCCONF Storage Adapter Linux Utility | smartpqi.arcconf-5.03.00.27960-0 | |||||
| Lenovo maxView (storman) Storage Adapter Linux Utility | smartpqi.storman-5.03.00.27959-0 | |||||
Lenovo Data Center Group Linux OS Support Home Page |
| linux.lenovo.com |
© 2018-2026 Lenovo. All rights reserved |