Lenovo YUM Repository



Targeted Server Family (Machine Type): ThinkSystem SR650 V4 Server (7DGC, 7DGD, 7DGE, 7DGF, 7DK2, 7DLN)
Targeted Operating System: SLES15SP6
YUM Repository Build Date: 2025_07_08

YUM Repository Release Version: SR630V4-SR650V4

Lenovo Hosted YUM Repository Configration Information


Lenovo Hosted Base URL: https://linux.lenovo.com/yum/2025_07/SR650V4_7DGC_7DGD_7DGE_7DGF_7DK2_7DLN/SLES15SP6

Lenovo Authenticity Security Key Download: https://download.lenovo.com/servers_pdf/LenovoDCG_publickey4096b2022-2025
Key Fingerprint:
pub   rsa4096 2022-08-25 [SC] [expires: 2025-08-24]       0026 1809 3EF3 205F 0C40  12EC FBE8 73B2 C37E 0DEC uid           [ultimate] dcgrepos (Lenovo Data Center Group Software Repository Public Key) <dcgrepos@lenovo.com> sub   rsa4096 2022-08-25 [E] [expires: 2025-08-24]


How to use Lenovo Linux YUM Device Driver Bundles

Supported Device Listing (Links to supported firmware/driver version information)
Device NameLenovo PN
Feature Code
Last Release Changed
ThinkSystem 48 port 12Gb Internal ExpanderPN: 4Y37A09736
FC: na
OSAgile25-2
All Supported NVMe Drives PN: NA
FC: na
OSAgile25-2
All Supported Solid State DrivesPN: NA
FC: na
OSAgile25-2
ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel AdapterPN: 4XC7A08276
FC: na
OSAgile25-2
ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel AdapterPN: 4XC7A08279
FC: na
OSAgile25-2
ThinkSystem QLogic QLE2872 64Gb 2-Port PCIe Fibre Channel Adapter (Generic FW)PN: 4XC7A96744
FC: na
OSAgile25-2
ThinkSystem Intel E610-T4 1GBASE-T 4-port OCP Ethernet Adapter(Generic FW)PN: 4XC7A96731
FC: na
SR630V4-SR650V4
ThinkSystem Intel E610-T4 10GBASE-T 4-port PCIe Ethernet Adapter(Generic FW)PN: 4XC7A96733
FC: na
SR630V4-SR650V4
ThinkSystem Intel E610-T4 10GBASE-T 4-port OCP Ethernet Adapter(Generic FW)PN: 4XC7A96734
FC: na
SR630V4-SR650V4
ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb AdapterPN: 4Y37A09728
FC: na
SR630V4-SR650V4
ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb AdapterPN: 4Y37A09730
FC: na
SR630V4-SR650V4
ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal AdapterPN: 4Y37A09735
FC: na
SR630V4-SR650V4
ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb AdapterPN: 4Y37A78836
FC: na
SR630V4-SR650V4
ThinkSystem RAID 545-8i PCIe Gen4 12Gb AdapterPN: 4Y37A93012
FC: na
OSAgile25-2
ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Enablement KitPN: 4Y37A90064
FC: na
OSAgile25-2
ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement KitPN: 4Y37A93014
FC: na
OSAgile25-2
ThinkSystem M.2 RAID B545i-2i SATA/NVMe Enablement KitPN: 4Y37A93746
FC: na
OSAgile25-2
ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBAPN: 4Y37A09724
FC: na
SR630V4-SR650V4
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBAPN: 4Y37A09725
FC: na
SR630V4-SR650V4
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBAPN: 4Y37A78602
FC: na
SR630V4-SR650V4
ThinkSystem Emulex LPe37102 32Gb 2-port PCIe Fibre Channel AdapterPN: 4XC7A96457
FC: na
SR630V4-SR650V4
ThinkSystem Emulex LPe38102 64Gb 2-port PCIe Fibre Channel AdapterPN: 4XC7A96458
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 5719 1GbE RJ45 4-port OCP Ethernet AdapterPN: 4XC7A08235
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet AdapterPN: 7ZT7A00484
FC: AUZV
SR630V4-SR650V4
ThinkSystem Broadcom 57416 10GBASE-T 2-port OCP Ethernet AdapterPN: 4XC7A08236
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet AdapterPN: 4XC7A08237
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet AdapterPN: 4XC7A08238
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57508 2x100/1x200GbE QSFP56 OCP Ethernet AdapterPN: 4XC7A08243
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57508 2x100/1x200GbE QSFP56 PCIe 4 Ethernet AdapterPN: 4XC7A08297
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port PCIe Ethernet AdapterPN: 4XC7A80566
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port OCP Ethernet AdapterPN: 4XC7A80567
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57608 2x200/1x400GbE QSFP112 PCIe Ethernet AdapterPN: 4XC7A95572
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57608 2x200/1x400GbE QSFP112 OCP Ethernet AdapterPN: 4XC7A95695
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57412 10GBASE-T 4-port OCP Ethernet AdapterPN: 4XC7A95696
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57412 10GBASE-T 4-port PCIe Ethernet AdapterPN: 4XC7A95697
FC: na
SR630V4-SR650V4
ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet AdapterPN: 7ZT7A00496
FC: AUKP
SR630V4-SR650V4
ThinkSystem 4350-16i SAS/SATA 12Gb HBAPN: 4Y37A72481
FC: na
SR630V4-SR650V4
ThinkSystem RAID 5350-8i PCIe 12Gb AdapterPN: 4Y37A72482
FC: na
SR630V4-SR650V4
ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb AdapterPN: 4Y37A72483
FC: na
SR630V4-SR650V4
ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb AdapterPN: 4Y37A72485
FC: na
SR630V4-SR650V4
Intel VROC Software RAID for NVMe Drives (Premium)PN: 4L47A39164
FC: na
SC750V4
Intel VROC Software RAID for NVMe Drives (Standard)PN: 4L47A83669
FC: na
SC750V4
Intel VROC RAID1 OnlyPN: 4L47A92670
FC: na
SC750V4
Intel VROC Software RAID for Intel NVMe DrivesPN: NA
FC: na
SC750V4


Device Supported Code Levels

ThinkSystem 48 port 12Gb Internal Expander Part Number: 4Y37A09736
Feature Code: na
Core System Device
Install Drivers on all Servers
Firmware Firmware Name Version
Last Release Change
Lenovo Expander Storage Host-Bus-Adapter (HBA) Linux Firmware exp.48p-j9bup-0011
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



All Supported NVMe Drives Part Number: NA_NVMe
Feature Code: na
Core System Device
Install Drivers on all Servers
Utility Utility Name Version
Last Release Change
Lenovo Wear Gauge Storage Linux Utility all.ss.wg-j9mk7-0171
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



All Supported Solid State Drives Part Number: NA_SSD
Feature Code: na
Core System Device
Install Drivers on all Servers
Utility Utility Name Version
Last Release Change
Lenovo Wear Gauge Storage Linux Utility all.ss.wg-j9mk7-0171
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel Adapter

Device Product Guide


Part Number: 4XC7A08276
Feature Code: na
PCIe Sub Vendor ID: 0x1077
PCIe Sub Device ID: 0x02F5
Driver Driver Name Discreate Package Download Version
Last Release Change
qlgc-qla2xxx-kmp-default
  enablement code
qlgc-qla2xxx-kmp-default-10.02.13.00_k_k6.4.0_150600.21-1.sles15sp6.sles15.6L016.x86_64.rpm 10.02.13.00_k_k6.4.0_150600.21
OSAgile25-2

Return to Device Listing



ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel Adapter

Device Product Guide


Part Number: 4XC7A08279
Feature Code: na
PCIe Sub Vendor ID: 0x1077
PCIe Sub Device ID: 0x02F4
Driver Driver Name Discreate Package Download Version
Last Release Change
qlgc-qla2xxx-kmp-default
  enablement code
qlgc-qla2xxx-kmp-default-10.02.13.00_k_k6.4.0_150600.21-1.sles15sp6.sles15.6L016.x86_64.rpm 10.02.13.00_k_k6.4.0_150600.21
OSAgile25-2

Return to Device Listing



ThinkSystem QLogic QLE2872 64Gb 2-Port PCIe Fibre Channel Adapter (Generic FW) Part Number: 4XC7A96744
Feature Code: na
PCIe Sub Vendor ID: 0x1077
PCIe Sub Device ID: 0x0200
Driver Driver Name Discreate Package Download Version
Last Release Change
qlgc-qla2xxx-kmp-default
  enablement code
qlgc-qla2xxx-kmp-default-10.02.13.00_k_k6.4.0_150600.21-1.sles15sp6.sles15.6L016.x86_64.rpm 10.02.13.00_k_k6.4.0_150600.21
OSAgile25-2

Return to Device Listing



ThinkSystem Intel E610-T4 1GBASE-T 4-port OCP Ethernet Adapter(Generic FW) Part Number: 4XC7A96731
Feature Code: na
PCIe Sub Vendor ID: 0x8086
PCIe Sub Device ID: 0x0003
Drivers Driver Name Discreate Package Download Version
Last Release Change
intel-ixgbe
  enablement code
intel-ixgbe-6.0.6-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6
SR630V4-SR650V4
intel-ixgbe-kmp-default
  enablement code
intel-ixgbe-kmp-default-6.0.6_k6.4.0_150600.21-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6_k6.4.0_150600.21
SR630V4-SR650V4
intel-ixgbevf
  enablement code
intel-ixgbevf-5.0.2-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2
SR630V4-SR650V4
intel-ixgbevf-kmp-default
  enablement code
intel-ixgbevf-kmp-default-5.0.2_k6.4.0_150600.21-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2_k6.4.0_150600.21
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Intel E610-T4 10GBASE-T 4-port PCIe Ethernet Adapter(Generic FW) Part Number: 4XC7A96733
Feature Code: na
PCIe Sub Vendor ID: 0x8086
PCIe Sub Device ID: 0x0001
Drivers Driver Name Discreate Package Download Version
Last Release Change
intel-ixgbe
  enablement code
intel-ixgbe-6.0.6-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6
SR630V4-SR650V4
intel-ixgbe-kmp-default
  enablement code
intel-ixgbe-kmp-default-6.0.6_k6.4.0_150600.21-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6_k6.4.0_150600.21
SR630V4-SR650V4
intel-ixgbevf
  enablement code
intel-ixgbevf-5.0.2-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2
SR630V4-SR650V4
intel-ixgbevf-kmp-default
  enablement code
intel-ixgbevf-kmp-default-5.0.2_k6.4.0_150600.21-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2_k6.4.0_150600.21
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Intel E610-T4 10GBASE-T 4-port OCP Ethernet Adapter(Generic FW) Part Number: 4XC7A96734
Feature Code: na
PCIe Sub Vendor ID: 0x8086
PCIe Sub Device ID: 0x0003
Drivers Driver Name Discreate Package Download Version
Last Release Change
intel-ixgbe
  enablement code
intel-ixgbe-6.0.6-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6
SR630V4-SR650V4
intel-ixgbe-kmp-default
  enablement code
intel-ixgbe-kmp-default-6.0.6_k6.4.0_150600.21-150600.1.1.sles15.6L02c.x86_64.rpm 6.0.6_k6.4.0_150600.21
SR630V4-SR650V4
intel-ixgbevf
  enablement code
intel-ixgbevf-5.0.2-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2
SR630V4-SR650V4
intel-ixgbevf-kmp-default
  enablement code
intel-ixgbevf-kmp-default-5.0.2_k6.4.0_150600.21-150600.150600.1.sles15.6L02c.x86_64.rpm 5.0.2_k6.4.0_150600.21
SR630V4-SR650V4

Return to Device Listing



ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter Part Number: 4Y37A09728
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x060A
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework RAID Adapter Linux Firmware mr3.5.940.ib-52.30.0-5632-j9vm9-0042
SR630V4-SR650V4
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter Part Number: 4Y37A09730
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x060C
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework RAID Adapter Linux Firmware mr3.5.940.ib-52.30.0-5632-j9vm9-0042
SR630V4-SR650V4
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter Part Number: 4Y37A09735
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x060D
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework RAID Adapter Linux Firmware mr3.5.940.ib-52.30.0-5632-j9vm9-0042
SR630V4-SR650V4
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter Part Number: 4Y37A78836
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x060F
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework RAID Adapter Linux Firmware mr3.5.940.ib-52.30.0-5632-j9vm9-0042
SR630V4-SR650V4
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem RAID 545-8i PCIe Gen4 12Gb Adapter Part Number: 4Y37A93012
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0507
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem M.2 RAID B540p-2HS SATA/NVMe Enablement Kit Part Number: 4Y37A90064
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0702
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem M.2 RAID B540d-2HS SATA/NVMe Enablement Kit Part Number: 4Y37A93014
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0703
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem M.2 RAID B545i-2i SATA/NVMe Enablement Kit Part Number: 4Y37A93746
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0704
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-megaraid_sas-kmp-default
  enablement code
lsi-megaraid_sas-kmp-default-07.732.03.00_k6.4.0_150600.21-1.sles15.6L01e.x86_64.rpm 07.732.03.00_k6.4.0_150600.21
OSAgile25-2
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority RAID Adapter Linux Utility mr3.lsa-008.012.007.000-j9vj3-0191
OSAgile25-2
Lenovo StorCLI RAID Adapter Linux Utility mr3.storcli-007.3205.0000.0000-1-j9vjc-0191
OSAgile25-2

Return to Device Listing



ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA Part Number: 4Y37A09724
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0206
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework Storage Host-Bus-Adapter (HBA) Linux Firmware mpt3.5.440.ib-j9c2e-0001
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-mpt3sas-kmp-default
  enablement code
lsi-mpt3sas-kmp-default-52.00.02.00_k6.4.0_150600.21-1.sles15.6L028.x86_64.rpm 52.00.02.00_k6.4.0_150600.21
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.lsa-008.012.007.000-j9vj3-0151
OSAgile25-2
Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.storcli-007.3205.0000.0000-1-j9vjc-0171
OSAgile25-2

Return to Device Listing



ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA

Device Product Guide


Part Number: 4Y37A09725
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0205
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework Storage Host-Bus-Adapter (HBA) Linux Firmware mpt3.5.440.ib-j9c2e-0001
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-mpt3sas-kmp-default
  enablement code
lsi-mpt3sas-kmp-default-52.00.02.00_k6.4.0_150600.21-1.sles15.6L028.x86_64.rpm 52.00.02.00_k6.4.0_150600.21
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.lsa-008.012.007.000-j9vj3-0151
OSAgile25-2
Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.storcli-007.3205.0000.0000-1-j9vjc-0171
OSAgile25-2

Return to Device Listing



ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA Part Number: 4Y37A78602
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0208
Firmware Firmware Name Version
Last Release Change
Lenovo Special Rework Storage Host-Bus-Adapter (HBA) Linux Firmware mpt3.5.440.ib-j9c2e-0001
OSAgile25-2
Driver Driver Name Discreate Package Download Version
Last Release Change
lsi-mpt3sas-kmp-default
  enablement code
lsi-mpt3sas-kmp-default-52.00.02.00_k6.4.0_150600.21-1.sles15.6L028.x86_64.rpm 52.00.02.00_k6.4.0_150600.21
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo LSI Storage Authority Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.lsa-008.012.007.000-j9vj3-0151
OSAgile25-2
Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Linux Utility mpt3.storcli-007.3205.0000.0000-1-j9vjc-0171
OSAgile25-2

Return to Device Listing



ThinkSystem Emulex LPe37102 32Gb 2-port PCIe Fibre Channel Adapter Part Number: 4XC7A96457
Feature Code: na
PCIe Sub Vendor ID: 0x10DF
PCIe Sub Device ID: 0xF518
Driver Driver Name Discreate Package Download Version
Last Release Change
elx-lpfc-kmp-default
  enablement code
elx-lpfc-kmp-default-14.4.393.46_k6.4.0_150600.21-1.sles15.6L032.x86_64.rpm 14.4.393.46_k6.4.0_150600.21
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Emulex LPe38102 64Gb 2-port PCIe Fibre Channel Adapter Part Number: 4XC7A96458
Feature Code: na
PCIe Sub Vendor ID: 0x10DF
PCIe Sub Device ID: 0xF516
Driver Driver Name Discreate Package Download Version
Last Release Change
elx-lpfc-kmp-default
  enablement code
elx-lpfc-kmp-default-14.4.393.46_k6.4.0_150600.21-1.sles15.6L032.x86_64.rpm 14.4.393.46_k6.4.0_150600.21
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 5719 1GbE RJ45 4-port OCP Ethernet Adapter

Device Product Guide


Part Number: 4XC7A08235
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4104
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-tg3-kmp-default
  enablement code
broadcom-tg3-kmp-default-3.139q_k6.4.0_150600.21-2.sles15sp6.sles15.6L014.x86_64.rpm 3.139q_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-tg3-doc
  enablement code
broadcom-tg3-doc-3.139q-2.sles15sp6.sles15.6L014.x86_64.rpm 3.139q
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter

Device Product Guide


Part Number: 7ZT7A00484
Feature Code: AUZV
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x402D
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-tg3-kmp-default
  enablement code
broadcom-tg3-kmp-default-3.139q_k6.4.0_150600.21-2.sles15sp6.sles15.6L014.x86_64.rpm 3.139q_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-tg3-doc
  enablement code
broadcom-tg3-doc-3.139q-2.sles15sp6.sles15.6L014.x86_64.rpm 3.139q
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57416 10GBASE-T 2-port OCP Ethernet Adapter

Device Product Guide


Part Number: 4XC7A08236
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4162
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port OCP Ethernet Adapter

Device Product Guide


Part Number: 4XC7A08237
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4140
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter

Device Product Guide


Part Number: 4XC7A08238
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4105
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57508 2x100/1x200GbE QSFP56 OCP Ethernet Adapter Part Number: 4XC7A08243
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4103
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57508 2x100/1x200GbE QSFP56 PCIe 4 Ethernet Adapter Part Number: 4XC7A08297
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x404C
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port PCIe Ethernet Adapter Part Number: 4XC7A80566
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4107
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port OCP Ethernet Adapter Part Number: 4XC7A80567
Feature Code: na
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4050
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57608 2x200/1x400GbE QSFP112 PCIe Ethernet Adapter Part Number: 4XC7A95572
Feature Code: na
PCIe Sub Vendor ID: 0x14E4
PCIe Sub Device ID: 0xA120
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57608 2x200/1x400GbE QSFP112 OCP Ethernet Adapter Part Number: 4XC7A95695
Feature Code: na
PCIe Sub Vendor ID: 0x14E4
PCIe Sub Device ID: 0x9320
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57412 10GBASE-T 4-port OCP Ethernet Adapter Part Number: 4XC7A95696
Feature Code: na
PCIe Sub Vendor ID: 0x14E4
PCIe Sub Device ID: 0xA340
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57412 10GBASE-T 4-port PCIe Ethernet Adapter Part Number: 4XC7A95697
Feature Code: na
PCIe Sub Vendor ID: 0x14E4
PCIe Sub Device ID: 0xA140
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter

Device Product Guide


Part Number: 7ZT7A00496
Feature Code: AUKP
PCIe Sub Vendor ID: 0x17AA
PCIe Sub Device ID: 0x4160
Drivers Driver Name Discreate Package Download Version
Last Release Change
broadcom-bnxt_en-kmp-default
  enablement code
broadcom-bnxt_en-kmp-default-1.10.3.232.0.155.5_k6.4.0_150600.21-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5_k6.4.0_150600.21
SR630V4-SR650V4
broadcom-bnxt_en-doc
  enablement code
broadcom-bnxt_en-doc-1.10.3.232.0.155.5-150600.1.1.sles15.6L054.x86_64.rpm 1.10.3.232.0.155.5
SR630V4-SR650V4
libbnxt_re
  enablement code
libbnxt_re-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4
libbnxt_re-devel
  enablement code
libbnxt_re-devel-232.0.155.5-sles15sp6.sles15.6L054.x86_64.rpm 232.0.155.5
SR630V4-SR650V4

Return to Device Listing



ThinkSystem 4350-16i SAS/SATA 12Gb HBA Part Number: 4Y37A72481
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0221
Driver Driver Name Discreate Package Download Version
Last Release Change
smartpqi-kmp-default
  enablement code
smartpqi-kmp-default-2.1.32-035.sles15sp6.sles15.6L030.x86_64.rpm 2.1.32
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo ARCCONF Storage Adapter Linux Utility smartpqi.arcconf-27147-j9mmp-02b1
SR630V4-SR650V4
Lenovo maxView (storman) Storage Adapter Linux Utility smartpqi.storman-27147-j9mmp-0331
SR630V4-SR650V4

Return to Device Listing



ThinkSystem RAID 5350-8i PCIe 12Gb Adapter Part Number: 4Y37A72482
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0520
Driver Driver Name Discreate Package Download Version
Last Release Change
smartpqi-kmp-default
  enablement code
smartpqi-kmp-default-2.1.32-035.sles15sp6.sles15.6L030.x86_64.rpm 2.1.32
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo ARCCONF Storage Adapter Linux Utility smartpqi.arcconf-27147-j9mmp-02b1
SR630V4-SR650V4
Lenovo maxView (storman) Storage Adapter Linux Utility smartpqi.storman-27147-j9mmp-0331
SR630V4-SR650V4

Return to Device Listing



ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter Part Number: 4Y37A72483
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0620
Driver Driver Name Discreate Package Download Version
Last Release Change
smartpqi-kmp-default
  enablement code
smartpqi-kmp-default-2.1.32-035.sles15sp6.sles15.6L030.x86_64.rpm 2.1.32
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo ARCCONF Storage Adapter Linux Utility smartpqi.arcconf-27147-j9mmp-02b1
SR630V4-SR650V4
Lenovo maxView (storman) Storage Adapter Linux Utility smartpqi.storman-27147-j9mmp-0331
SR630V4-SR650V4

Return to Device Listing



ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter Part Number: 4Y37A72485
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0622
Driver Driver Name Discreate Package Download Version
Last Release Change
smartpqi-kmp-default
  enablement code
smartpqi-kmp-default-2.1.32-035.sles15sp6.sles15.6L030.x86_64.rpm 2.1.32
SR630V4-SR650V4
Utilities Utility Name Version
Last Release Change
Lenovo ARCCONF Storage Adapter Linux Utility smartpqi.arcconf-27147-j9mmp-02b1
SR630V4-SR650V4
Lenovo maxView (storman) Storage Adapter Linux Utility smartpqi.storman-27147-j9mmp-0331
SR630V4-SR650V4

Return to Device Listing



Intel VROC Software RAID for NVMe Drives (Premium) Part Number: 4L47A39164
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x1010
Utility Utility Name Version
Last Release Change
Intel Software Based RAID Linux Utility vroc.nvme.oob.tsv4-9.1.0.1029-j9vga-01b1
SC750V4
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



Intel VROC Software RAID for NVMe Drives (Standard) Part Number: 4L47A83669
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x101D
Utility Utility Name Version
Last Release Change
Intel Software Based RAID Linux Utility vroc.nvme.oob.tsv4-9.1.0.1029-j9vga-01b1
SC750V4
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



Intel VROC RAID1 Only Part Number: 4L47A92670
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x0115
Utility Utility Name Version
Last Release Change
Intel Software Based RAID Linux Utility vroc.nvme.oob.tsv4-9.1.0.1029-j9vga-01b1
SC750V4
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing



Intel VROC Software RAID for Intel NVMe Drives Part Number: NA
Feature Code: na
PCIe Sub Vendor ID: 0x1D49
PCIe Sub Device ID: 0x101D
Utility Utility Name Version
Last Release Change
Intel Software Based RAID Linux Utility vroc.nvme.oob.tsv4-9.1.0.1029-j9vga-01b1
SC750V4
Driver Driver Name Discreate Package Download Version
Last Release Change
InBox Driver provided by Linux Distro install supported

Return to Device Listing






Lenovo Data Center Group Linux OS Support Home Page
linux.lenovo.com

© 2018-2025 Lenovo. All rights reserved